WorldWideScience

Sample records for maximum frame rate

  1. Frame Rate and Human Vision

    Science.gov (United States)

    Watson, Andrew B.

    2012-01-01

    To enhance the quality of the theatre experience, the film industry is interested in achieving higher frame rates for capture and display. In this talk I will describe the basic spatio-temporal sensitivities of human vision, and how they respond to the time sequence of static images that is fundamental to cinematic presentation.

  2. High-frame-rate digital radiographic videography

    Science.gov (United States)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  3. High frame rate synthetic aperture duplex imaging

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Pihl, Michael Johannes

    2013-01-01

    aperture flow imaging as demonstrated in this paper. Synthetic aperture, directional beamforming, and cross-correlation are used to produce B-mode and vector velocity images at high frame rates. The frame rate equals the effective pulse repetition frequency of each imaging mode. Emissions for making the B...... estimation is −1.8% and the relative standard deviation 5.4%. The approach can thus estimate both high and low velocities with equal accuracy and thereby makes it possible to present vector flow images with a high dynamic range. Measurements are made using the SARUS research scanner, a linear array......Conventional color flow images are limited in velocity range and can either show the high velocities in systole or be optimized for the lower diastolic velocities. The full dynamics of the flow is, thus, hard to visualize. The dynamic range can be significantly increased by employing synthetic...

  4. Multiresolution Motion Estimation for Low-Rate Video Frame Interpolation

    Directory of Open Access Journals (Sweden)

    Hezerul Abdul Karim

    2004-09-01

    Full Text Available Interpolation of video frames with the purpose of increasing the frame rate requires the estimation of motion in the image so as to interpolate pixels along the path of the objects. In this paper, the specific challenges of low-rate video frame interpolation are illustrated by choosing one well-performing algorithm for high-frame-rate interpolation (Castango 1996 and applying it to low frame rates. The degradation of performance is illustrated by comparing the original algorithm, the algorithm adapted to low frame rate, and simple averaging. To overcome the particular challenges of low-frame-rate interpolation, two algorithms based on multiresolution motion estimation are developed and compared on objective and subjective basis and shown to provide an elegant solution to the specific challenges of low-frame-rate video interpolation.

  5. Maximum entropy production rate in quantum thermodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Beretta, Gian Paolo, E-mail: beretta@ing.unibs.i [Universita di Brescia, via Branze 38, 25123 Brescia (Italy)

    2010-06-01

    In the framework of the recent quest for well-behaved nonlinear extensions of the traditional Schroedinger-von Neumann unitary dynamics that could provide fundamental explanations of recent experimental evidence of loss of quantum coherence at the microscopic level, a recent paper [Gheorghiu-Svirschevski 2001 Phys. Rev. A 63 054102] reproposes the nonlinear equation of motion proposed by the present author [see Beretta G P 1987 Found. Phys. 17 365 and references therein] for quantum (thermo)dynamics of a single isolated indivisible constituent system, such as a single particle, qubit, qudit, spin or atomic system, or a Bose-Einstein or Fermi-Dirac field. As already proved, such nonlinear dynamics entails a fundamental unifying microscopic proof and extension of Onsager's reciprocity and Callen's fluctuation-dissipation relations to all nonequilibrium states, close and far from thermodynamic equilibrium. In this paper we propose a brief but self-contained review of the main results already proved, including the explicit geometrical construction of the equation of motion from the steepest-entropy-ascent ansatz and its exact mathematical and conceptual equivalence with the maximal-entropy-generation variational-principle formulation presented in Gheorghiu-Svirschevski S 2001 Phys. Rev. A 63 022105. Moreover, we show how it can be extended to the case of a composite system to obtain the general form of the equation of motion, consistent with the demanding requirements of strong separability and of compatibility with general thermodynamics principles. The irreversible term in the equation of motion describes the spontaneous attraction of the state operator in the direction of steepest entropy ascent, thus implementing the maximum entropy production principle in quantum theory. The time rate at which the path of steepest entropy ascent is followed has so far been left unspecified. As a step towards the identification of such rate, here we propose a possible

  6. Current control of PMSM based on maximum torque control reference frame

    Science.gov (United States)

    Ohnuma, Takumi

    2017-07-01

    This study presents a new method of current controls of PMSMs (Permanent Magnet Synchronous Motors) based on a maximum torque control reference frame, which is suitable for high-performance controls of the PMSMs. As the issues of environment and energy increase seriously, PMSMs, one of the AC motors, are becoming popular because of their high-efficiency and high-torque density in various applications, such as electric vehicles, trains, industrial machines, and home appliances. To use the PMSMs efficiently, a proper current control of the PMSMs is necessary. In general, a rotational coordinate system synchronizing with the rotor is used for the current control of PMSMs. In the rotating reference frame, the current control is easier because the currents on the rotating reference frame can be expressed as a direct current in the controller. On the other hand, the torque characteristics of PMSMs are non-linear and complex; the PMSMs are efficient and high-density though. Therefore, a complicated control system is required to involve the relation between the torque and the current, even though the rotating reference frame is adopted. The maximum torque control reference frame provides a simpler way to control efficiently the currents taking the torque characteristics of the PMSMs into consideration.

  7. 7 CFR 3565.210 - Maximum interest rate.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Maximum interest rate. 3565.210 Section 3565.210... AGRICULTURE GUARANTEED RURAL RENTAL HOUSING PROGRAM Loan Requirements § 3565.210 Maximum interest rate. The interest rate for a guaranteed loan must not exceed the maximum allowable rate specified by the Agency in...

  8. Robust Multi-Frame Adaptive Optics Image Restoration Algorithm Using Maximum Likelihood Estimation with Poisson Statistics

    Directory of Open Access Journals (Sweden)

    Dongming Li

    2017-04-01

    Full Text Available An adaptive optics (AO system provides real-time compensation for atmospheric turbulence. However, an AO image is usually of poor contrast because of the nature of the imaging process, meaning that the image contains information coming from both out-of-focus and in-focus planes of the object, which also brings about a loss in quality. In this paper, we present a robust multi-frame adaptive optics image restoration algorithm via maximum likelihood estimation. Our proposed algorithm uses a maximum likelihood method with image regularization as the basic principle, and constructs the joint log likelihood function for multi-frame AO images based on a Poisson distribution model. To begin with, a frame selection method based on image variance is applied to the observed multi-frame AO images to select images with better quality to improve the convergence of a blind deconvolution algorithm. Then, by combining the imaging conditions and the AO system properties, a point spread function estimation model is built. Finally, we develop our iterative solutions for AO image restoration addressing the joint deconvolution issue. We conduct a number of experiments to evaluate the performances of our proposed algorithm. Experimental results show that our algorithm produces accurate AO image restoration results and outperforms the current state-of-the-art blind deconvolution methods.

  9. High frame rate imaging based photometry

    DEFF Research Database (Denmark)

    Harpsøe, Kennet Bomann West; Jørgensen, U. G.; Andersen, M. I.

    2012-01-01

    in extremely crowded fields significantly by alleviating crowding. Alleviating crowding is a prerequisite for observing gravitational microlensing in main sequence stars towards the galactic bulge. However, the photometric stability of this device has not been assessed. The EMCCD has sources of noise not found...... in conventional CCDs, and new methods for handling these must be developed. We aim to investigate how the normal photometric reduction steps from conventional CCDs should be adjusted to be applicable to EMCCD data. One complication is that a bias frame cannot be obtained conventionally, as the output from...

  10. 5 CFR 531.221 - Maximum payable rate rule.

    Science.gov (United States)

    2010-01-01

    ... before the reassignment. (ii) If the rate resulting from the geographic conversion under paragraph (c)(2... previous rate (i.e., the former special rate after the geographic conversion) with the rates on the current... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Maximum payable rate rule. 531.221...

  11. Maximum organic carbon limits at different melter feed rates (U)

    International Nuclear Information System (INIS)

    Choi, A.S.

    1995-01-01

    This report documents the results of a study to assess the impact of varying melter feed rates on the maximum total organic carbon (TOC) limits allowable in the DWPF melter feed. Topics discussed include: carbon content; feed rate; feed composition; melter vapor space temperature; combustion and dilution air; off-gas surges; earlier work on maximum TOC; overview of models; and the results of the work completed

  12. Dinosaur Metabolism and the Allometry of Maximum Growth Rate

    OpenAIRE

    Myhrvold, Nathan P.

    2016-01-01

    The allometry of maximum somatic growth rate has been used in prior studies to classify the metabolic state of both extant vertebrates and dinosaurs. The most recent such studies are reviewed, and their data is reanalyzed. The results of allometric regressions on growth rate are shown to depend on the choice of independent variable; the typical choice used in prior studies introduces a geometric shear transformation that exaggerates the statistical power of the regressions. The maximum growth...

  13. High Frame Rate Synthetic Aperture 3D Vector Flow Imaging

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Holbek, Simon; Stuart, Matthias Bo

    2016-01-01

    , current volumetric ultrasonic flow methods are limited to one velocity component or restricted to a reduced field of view (FOV), e.g. fixed imaging planes, in exchange for higher temporal resolutions. To solve these problems, a previously proposed accurate 2-D high frame rate vector flow imaging (VFI...

  14. Monolithic array of 32 SPAD pixels for single-photon imaging at high frame rates

    International Nuclear Information System (INIS)

    Tisa, Simone; Guerrieri, Fabrizio; Zappa, Franco

    2009-01-01

    We present a single-chip monolithic array of 32 Single-Photon Avalanche Diodes (SPAD) and associated electronics for imaging at high frame rates and high sensitivity. Photodetectors, front-end circuitry and control electronics used to manage the array are monolithically integrated on the same chip in a standard 0.35 μm CMOS high-voltage technology. The array is composed of 32 'smart' pixels working in photon counting mode and functioning in a parallel fashion. Every cell comprises of an integrated SPAD photodetector, a novel quenching circuit named as Variable Load Quenching Circuit (VLQC), counting electronics and a buffer memory. Proper ancillary electronics that perform the arbitration of photon counts between two consecutive frames is integrated as well. Thanks to the presence of in-pixel memory registers, the inter-frame dead time between subsequent frames is limited to few nanoseconds. Since integration and download are performed simultaneously and the array can be addressed like a standard digital memory, the achievable maximum frame rate is very high in the order of hundreds of thousands of frame/s.

  15. The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Stephen, E-mail: syip@lroc.harvard.edu; Rottmann, Joerg; Berbeco, Ross [Department of Radiation Oncology, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2014-06-15

    Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID

  16. The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking

    International Nuclear Information System (INIS)

    Yip, Stephen; Rottmann, Joerg; Berbeco, Ross

    2014-01-01

    Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID

  17. 44 CFR 208.12 - Maximum Pay Rate Table.

    Science.gov (United States)

    2010-10-01

    ...) Physicians. DHS uses the latest Special Salary Rate Table Number 0290 for Medical Officers (Clinical... Personnel, in which case the Maximum Pay Rate Table would not apply. (3) Compensation for Sponsoring Agency... organizations, e.g., HMOs or medical or engineering professional associations, under the revised definition of...

  18. Seismic Load Rating Procedure for Welded Steel Frames Oligo-cyclic Fatigue

    International Nuclear Information System (INIS)

    Ratiu, Mircea D.; Moisidis, Nicolae T.

    2004-01-01

    A dynamic load rating approach for seismic qualification of cold-formed steel welded frames is presented. Allowable seismic loads are developed from cyclic and monotonic tests of standard cold-formed steel components commonly used for piping and electrical raceway supports. The method permits simplified qualification of all connections of frame components through a single load comparison. Test input consists of rotation/cycles-to-failure data and monotonic moment/rotation data. Cyclic data are statistically evaluated to determine an acceptable maximum seismic rotation for the connection. The allowable seismic load is determined from the corresponding static rotation. Application to seismic qualification procedures is discussed. (authors)

  19. Compact Beamformer Design with High Frame Rate for Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2014-04-01

    Full Text Available In medical field, two-dimension ultrasound images are widely used in clinical diagnosis. Beamformer is critical in determining the complexity and performance of an ultrasound imaging system. Different from traditional means implemented with separated chips, a compact beamformer with 64 effective channels in a single moderate Field Programmable Gate Array has been presented in this paper. The compactness is acquired by employing receive synthetic aperture, harmonic imaging, time sharing and linear interpolation. Besides that, multi-beams method is used to improve the frame rate of the ultrasound imaging system. Online dynamic configuration is employed to expand system’s flexibility to two kinds of transducers with multi-scanning modes. The design is verified on a prototype scanner board. Simulation results have shown that on-chip memories can be saved and the frame rate can be improved on the case of 64 effective channels which will meet the requirement of real-time application.

  20. 50 CFR Figures 14a and 14b to Part... - Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and...

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and Maximum Angle of Deflector Bars With Bent Bars... 223—Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and Maximum...

  1. Joint variable frame rate and length analysis for speech recognition under adverse conditions

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Kraljevski, Ivan

    2014-01-01

    This paper presents a method that combines variable frame length and rate analysis for speech recognition in noisy environments, together with an investigation of the effect of different frame lengths on speech recognition performance. The method adopts frame selection using an a posteriori signal......-to-noise (SNR) ratio weighted energy distance and increases the length of the selected frames, according to the number of non-selected preceding frames. It assigns a higher frame rate and a normal frame length to a rapidly changing and high SNR region of a speech signal, and a lower frame rate and an increased...... frame length to a steady or low SNR region. The speech recognition results show that the proposed variable frame rate and length method outperforms fixed frame rate and length analysis, as well as standalone variable frame rate analysis in terms of noise-robustness....

  2. Dinosaur Metabolism and the Allometry of Maximum Growth Rate.

    Science.gov (United States)

    Myhrvold, Nathan P

    2016-01-01

    The allometry of maximum somatic growth rate has been used in prior studies to classify the metabolic state of both extant vertebrates and dinosaurs. The most recent such studies are reviewed, and their data is reanalyzed. The results of allometric regressions on growth rate are shown to depend on the choice of independent variable; the typical choice used in prior studies introduces a geometric shear transformation that exaggerates the statistical power of the regressions. The maximum growth rates of extant groups are found to have a great deal of overlap, including between groups with endothermic and ectothermic metabolism. Dinosaur growth rates show similar overlap, matching the rates found for mammals, reptiles and fish. The allometric scaling of growth rate with mass is found to have curvature (on a log-log scale) for many groups, contradicting the prevailing view that growth rate allometry follows a simple power law. Reanalysis shows that no correlation between growth rate and basal metabolic rate (BMR) has been demonstrated. These findings drive a conclusion that growth rate allometry studies to date cannot be used to determine dinosaur metabolism as has been previously argued.

  3. Dinosaur Metabolism and the Allometry of Maximum Growth Rate

    Science.gov (United States)

    Myhrvold, Nathan P.

    2016-01-01

    The allometry of maximum somatic growth rate has been used in prior studies to classify the metabolic state of both extant vertebrates and dinosaurs. The most recent such studies are reviewed, and their data is reanalyzed. The results of allometric regressions on growth rate are shown to depend on the choice of independent variable; the typical choice used in prior studies introduces a geometric shear transformation that exaggerates the statistical power of the regressions. The maximum growth rates of extant groups are found to have a great deal of overlap, including between groups with endothermic and ectothermic metabolism. Dinosaur growth rates show similar overlap, matching the rates found for mammals, reptiles and fish. The allometric scaling of growth rate with mass is found to have curvature (on a log-log scale) for many groups, contradicting the prevailing view that growth rate allometry follows a simple power law. Reanalysis shows that no correlation between growth rate and basal metabolic rate (BMR) has been demonstrated. These findings drive a conclusion that growth rate allometry studies to date cannot be used to determine dinosaur metabolism as has been previously argued. PMID:27828977

  4. Cheetah: A high frame rate, high resolution SWIR image camera

    Science.gov (United States)

    Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob

    2008-10-01

    A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.

  5. Maximum discharge rate of liquid-vapor mixtures from vessels

    International Nuclear Information System (INIS)

    Moody, F.J.

    1975-09-01

    A discrepancy exists in theoretical predictions of the two-phase equilibrium discharge rate from pipes attached to vessels. Theory which predicts critical flow data in terms of pipe exit pressure and quality severely overpredicts flow rates in terms of vessel fluid properties. This study shows that the discrepancy is explained by the flow pattern. Due to decompression and flashing as fluid accelerates into the pipe entrance, the maximum discharge rate from a vessel is limited by choking of a homogeneous bubbly mixture. The mixture tends toward a slip flow pattern as it travels through the pipe, finally reaching a different choked condition at the pipe exit

  6. Fumigant dosages below maximum label rate control some soilborne pathogens

    Directory of Open Access Journals (Sweden)

    Shachaf Triky-Dotan

    2016-08-01

    Full Text Available The activity of commercial soil fumigants on some key soilborne pathogens was assessed in sandy loam soil under controlled conditions. Seven soil fumigants that are registered in California or are being or have been considered for registration were used in this study: dimethyl disulfide (DMDS mixed with chloropicrin (Pic (79% DMDS and 21% Pic, Tri-Con (50% methyl bromide and 50% Pic, Midas Gold (33% methyl iodide [MI] and 67% Pic, Midas Bronze (50% MI and 50% Pic, Midas (MI, active ingredient [a.i.] 97.8%, Pic (a.i. 99% trichloronitromethane and Pic-Clor 60 (57% Pic and 37% 1,3-dichloropropene [1–3,D]. Dose-response models were calculated for pathogen mortality after 24 hours of exposure to fumigants. Overall, the tested fumigants achieved good efficacy with dosages below the maximum label rate against the tested pathogens. In this study, Pythium ultimum and citrus nematode were sensitive to all the fumigants and Verticillium dahliae was resistant. For most fumigants, California regulations restrict application rates to less than the maximum (federal label rate, meaning that it is possible that the fumigants may not control major plant pathogens. This research provides information on the effectiveness of these alternatives at these lower application rates. The results from this study will help growers optimize application rates for registered fumigants (such as Pic and 1,3-D and will help accelerate the adoption of new fumigants (such as DMDS if they are registered in California.

  7. High-Order Model and Dynamic Filtering for Frame Rate Up-Conversion.

    Science.gov (United States)

    Bao, Wenbo; Zhang, Xiaoyun; Chen, Li; Ding, Lianghui; Gao, Zhiyong

    2018-08-01

    This paper proposes a novel frame rate up-conversion method through high-order model and dynamic filtering (HOMDF) for video pixels. Unlike the constant brightness and linear motion assumptions in traditional methods, the intensity and position of the video pixels are both modeled with high-order polynomials in terms of time. Then, the key problem of our method is to estimate the polynomial coefficients that represent the pixel's intensity variation, velocity, and acceleration. We propose to solve it with two energy objectives: one minimizes the auto-regressive prediction error of intensity variation by its past samples, and the other minimizes video frame's reconstruction error along the motion trajectory. To efficiently address the optimization problem for these coefficients, we propose the dynamic filtering solution inspired by video's temporal coherence. The optimal estimation of these coefficients is reformulated into a dynamic fusion of the prior estimate from pixel's temporal predecessor and the maximum likelihood estimate from current new observation. Finally, frame rate up-conversion is implemented using motion-compensated interpolation by pixel-wise intensity variation and motion trajectory. Benefited from the advanced model and dynamic filtering, the interpolated frame has much better visual quality. Extensive experiments on the natural and synthesized videos demonstrate the superiority of HOMDF over the state-of-the-art methods in both subjective and objective comparisons.

  8. High frame-rate neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Bossi, R.H.; Robinson, A.H.; Barton, J.P.

    1981-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two-phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10 11 n/cm 2 s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance

  9. High frame-rate neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Bossi, R.H.; Robinson, A.H.; Barton, J.P.

    1983-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10 11 n/cm 2 s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance. (Auth.)

  10. Analysis of reaction schemes using maximum rates of constituent steps

    Science.gov (United States)

    Motagamwala, Ali Hussain; Dumesic, James A.

    2016-01-01

    We show that the steady-state kinetics of a chemical reaction can be analyzed analytically in terms of proposed reaction schemes composed of series of steps with stoichiometric numbers equal to unity by calculating the maximum rates of the constituent steps, rmax,i, assuming that all of the remaining steps are quasi-equilibrated. Analytical expressions can be derived in terms of rmax,i to calculate degrees of rate control for each step to determine the extent to which each step controls the rate of the overall stoichiometric reaction. The values of rmax,i can be used to predict the rate of the overall stoichiometric reaction, making it possible to estimate the observed reaction kinetics. This approach can be used for catalytic reactions to identify transition states and adsorbed species that are important in controlling catalyst performance, such that detailed calculations using electronic structure calculations (e.g., density functional theory) can be carried out for these species, whereas more approximate methods (e.g., scaling relations) are used for the remaining species. This approach to assess the feasibility of proposed reaction schemes is exact for reaction schemes where the stoichiometric coefficients of the constituent steps are equal to unity and the most abundant adsorbed species are in quasi-equilibrium with the gas phase and can be used in an approximate manner to probe the performance of more general reaction schemes, followed by more detailed analyses using full microkinetic models to determine the surface coverages by adsorbed species and the degrees of rate control of the elementary steps. PMID:27162366

  11. Framing violence: the effect of survey context and question framing on reported rates of partner violence

    OpenAIRE

    Regan, Katherine V.

    2008-01-01

    In this dissertation, I investigated two explanations for the variability in levels of partner violence found by large community surveys. In Study 1, I examined the effect of how questions about partner violence are introduced (question framing: conflict, violence-in-relationships, or attacks) on reports of partner violence. Although there was not a reliable effect of question framing, the pattern of findings was consistent across 3 of 4 analyses. Counter to predictions, an attacks question f...

  12. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function

    NARCIS (Netherlands)

    Coolen, Bram F.; Abdurrachim, Desiree; Motaal, Abdallah G.; Nicolay, Klaas; Prompers, Jeanine J.; Strijkers, Gustav J.

    2013-01-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered

  13. Exercise-induced maximum metabolic rate scaled to body mass by ...

    African Journals Online (AJOL)

    Exercise-induced maximum metabolic rate scaled to body mass by the fractal ... rate scaling is that exercise-induced maximum aerobic metabolic rate (MMR) is ... muscle stress limitation, and maximized oxygen delivery and metabolic rates.

  14. Laryngeal High-Speed Videoendoscopy: Sensitivity of Objective Parameters towards Recording Frame Rate

    Directory of Open Access Journals (Sweden)

    Anne Schützenberger

    2016-01-01

    Full Text Available The current use of laryngeal high-speed videoendoscopy in clinic settings involves subjective visual assessment of vocal fold vibratory characteristics. However, objective quantification of vocal fold vibrations for evidence-based diagnosis and therapy is desired, and objective parameters assessing laryngeal dynamics have therefore been suggested. This study investigated the sensitivity of the objective parameters and their dependence on recording frame rate. A total of 300 endoscopic high-speed videos with recording frame rates between 1000 and 15 000 fps were analyzed for a vocally healthy female subject during sustained phonation. Twenty parameters, representing laryngeal dynamics, were computed. Four different parameter characteristics were found: parameters showing no change with increasing frame rate; parameters changing up to a certain frame rate, but then remaining constant; parameters remaining constant within a particular range of recording frame rates; and parameters changing with nearly every frame rate. The results suggest that (1 parameter values are influenced by recording frame rates and different parameters have varying sensitivities to recording frame rate; (2 normative values should be determined based on recording frame rates; and (3 the typically used recording frame rate of 4000 fps seems to be too low to distinguish accurately certain characteristics of the human phonation process in detail.

  15. The mechanics of granitoid systems and maximum entropy production rates.

    Science.gov (United States)

    Hobbs, Bruce E; Ord, Alison

    2010-01-13

    A model for the formation of granitoid systems is developed involving melt production spatially below a rising isotherm that defines melt initiation. Production of the melt volumes necessary to form granitoid complexes within 10(4)-10(7) years demands control of the isotherm velocity by melt advection. This velocity is one control on the melt flux generated spatially just above the melt isotherm, which is the control valve for the behaviour of the complete granitoid system. Melt transport occurs in conduits initiated as sheets or tubes comprising melt inclusions arising from Gurson-Tvergaard constitutive behaviour. Such conduits appear as leucosomes parallel to lineations and foliations, and ductile and brittle dykes. The melt flux generated at the melt isotherm controls the position of the melt solidus isotherm and hence the physical height of the Transport/Emplacement Zone. A conduit width-selection process, driven by changes in melt viscosity and constitutive behaviour, operates within the Transport Zone to progressively increase the width of apertures upwards. Melt can also be driven horizontally by gradients in topography; these horizontal fluxes can be similar in magnitude to vertical fluxes. Fluxes induced by deformation can compete with both buoyancy and topographic-driven flow over all length scales and results locally in transient 'ponds' of melt. Pluton emplacement is controlled by the transition in constitutive behaviour of the melt/magma from elastic-viscous at high temperatures to elastic-plastic-viscous approaching the melt solidus enabling finite thickness plutons to develop. The system involves coupled feedback processes that grow at the expense of heat supplied to the system and compete with melt advection. The result is that limits are placed on the size and time scale of the system. Optimal characteristics of the system coincide with a state of maximum entropy production rate. This journal is © 2010 The Royal Society

  16. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function.

    Science.gov (United States)

    Coolen, Bram F; Abdurrachim, Desiree; Motaal, Abdallah G; Nicolay, Klaas; Prompers, Jeanine J; Strijkers, Gustav J

    2013-03-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered at will to increase the frame rate because of gradient hardware, spatial resolution, and signal-to-noise limitations. To overcome these limitations associated with electrocardiography-triggered Cine MRI, in this paper, we introduce a retrospectively triggered Cine MRI protocol capable of producing high-resolution high frame rate Cine MRI of the mouse heart for addressing left ventricular diastolic function. Simulations were performed to investigate the influence of MRI sequence parameters and the k-space filling trajectory in relation to the desired number of frames per cardiac cycle. An optimized protocol was applied in vivo and compared with electrocardiography-triggered Cine for which a high-frame rate could only be achieved by several interleaved acquisitions. Retrospective high frame rate Cine MRI proved superior to the interleaved electrocardiography-triggered protocols. High spatial-resolution Cine movies with frames rates up to 80 frames per cardiac cycle were obtained in 25 min. Analysis of left ventricular filling rate curves allowed accurate determination of early and late filling rates and revealed subtle impairments in left ventricular diastolic function of diabetic mice in comparison with nondiabetic mice. Copyright © 2012 Wiley Periodicals, Inc.

  17. 78 FR 13999 - Maximum Interest Rates on Guaranteed Farm Loans

    Science.gov (United States)

    2013-03-04

    ..., cost-plus, flat-rate, or market based) to price guaranteed loans, provided the rates do not exceed the... (LIBOR) or the 5-year Treasury note rate, unless the lender uses a formal written risk-based pricing... cost in the form of a lower interest rate than the borrower would otherwise receive. Therefore, the FSA...

  18. Low-Complexity Variable Frame Rate Analysis for Speech Recognition and Voice Activity Detection

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    present a low-complexity and effective frame selection approach based on a posteriori signal-to-noise ratio (SNR) weighted energy distance: The use of an energy distance, instead of e.g. a standard cepstral distance, makes the approach computationally efficient and enables fine granularity search......Frame based speech processing inherently assumes a stationary behavior of speech signals in a short period of time. Over a long time, the characteristics of the signals can change significantly and frames are not equally important, underscoring the need for frame selection. In this paper, we......, and the use of a posteriori SNR weighting emphasizes the reliable regions in noisy speech signals. It is experimentally found that the approach is able to assign a higher frame rate to fast changing events such as consonants, a lower frame rate to steady regions like vowels and no frames to silence, even...

  19. The tropical lapse rate steepened during the Last Glacial Maximum

    NARCIS (Netherlands)

    Loomis, S.E.; Russell, J.M.; Verschuren, D.; Morrill, C.; De Cort, G.; Sinninghe Damsté, J.S.; Olago, D.; Eggermont, H.; Street-Perrott, F.A.; Kelly, M.A.

    2017-01-01

    The gradient of air temperature with elevation (the temperature lapse rate) in the tropics is predicted to become lesssteep during the coming century as surface temperature rises, enhancing the threat of warming in high-mountainenvironments. However, the sensitivity of the lapse rate to climate

  20. The tropical lapse rate steepened during the Last Glacial Maximum

    NARCIS (Netherlands)

    Loomis, Shannon E; Russell, James M; Verschuren, Dirk; Morrill, Carrie; De Cort, Gijs; Sinninghe Damsté, Jaap S; Olago, Daniel; Eggermont, Hilde; Street-Perrott, F Alayne; Kelly, Meredith A

    The gradient of air temperature with elevation (the temperature lapse rate) in the tropics is predicted to become less steep during the coming century as surface temperature rises, enhancing the threat of warming in high-mountain environments. However, the sensitivity of the lapse rate to climate

  1. Objective assessment of the impact of frame rate on video quality

    DEFF Research Database (Denmark)

    Ukhanova, Ann; Korhonen, Jari; Forchhammer, Søren

    2012-01-01

    In this paper, we present a novel objective quality metric that takes the impact of frame rate into account. The proposed metric uses PSNR, frame rate and a content dependent parameter that can easily be obtained from spatial and temporal activity indices. The results have been validated on data ...

  2. Demo : an embedded vision system for high frame rate visual servoing

    NARCIS (Netherlands)

    Ye, Z.; He, Y.; Pieters, R.S.; Mesman, B.; Corporaal, H.; Jonker, P.P.

    2011-01-01

    The frame rate of commercial off-the-shelf industrial cameras is breaking the threshold of 1000 frames-per-second, the sample rate required in high performance motion control systems. On the one hand, it enables computer vision as a cost-effective feedback source; On the other hand, it imposes

  3. The effects of frame rate and resolution on users playing first person shooter games

    Science.gov (United States)

    Claypool, Mark; Claypool, Kajal; Damaa, Feissal

    2006-01-01

    The rates and resolutions for frames rendered in a computer game directly impact the player performance, influencing both the overall game playability and the game's enjoyability. Insights into the effects of frame rates and resolutions can guide users in their choice for game settings and new hardware purchases, and inform system designers in their development of new hardware, especially for embedded devices that often must make tradeoffs between resolution and frame rate. While there have been studies detailing the effects of frame rate and resolution on streaming video and other multimedia applications, to the best of our knowledge, there have been no studies quantifying the effects of frame rate and resolution on user performance for computer games. This paper presents results of a carefully designed user study that measures the impact of frame rate and frame resolution on user performance in a first person shooter game. Contrary to previous results for streaming video, frame rate has a marked impact on both player performance and game enjoyment while resolution has little impact on performance and some impact on enjoyment.

  4. Variable Frame Rate and Length Analysis for Data Compression in Distributed Speech Recognition

    DEFF Research Database (Denmark)

    Kraljevski, Ivan; Tan, Zheng-Hua

    2014-01-01

    This paper addresses the issue of data compression in distributed speech recognition on the basis of a variable frame rate and length analysis method. The method first conducts frame selection by using a posteriori signal-to-noise ratio weighted energy distance to find the right time resolution...... length for steady regions. The method is applied to scalable source coding in distributed speech recognition where the target bitrate is met by adjusting the frame rate. Speech recognition results show that the proposed approach outperforms other compression methods in terms of recognition accuracy...... for noisy speech while achieving higher compression rates....

  5. Multi-Frame Rate Based Multiple-Model Training for Robust Speaker Identification of Disguised Voice

    DEFF Research Database (Denmark)

    Prasad, Swati; Tan, Zheng-Hua; Prasad, Ramjee

    2013-01-01

    Speaker identification systems are prone to attack when voice disguise is adopted by the user. To address this issue,our paper studies the effect of using different frame rates on the accuracy of the speaker identification system for disguised voice.In addition, a multi-frame rate based multiple......-model training method is proposed. The experimental results show the superior performance of the proposed method compared to the commonly used single frame rate method for three types of disguised voice taken from the CHAINS corpus....

  6. Minimum Variance Beamforming for High Frame-Rate Ultrasound Imaging

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund; Gran, Fredrik; Jensen, Jørgen Arendt

    2007-01-01

    , a 7 MHz, 128-element, phased array transducer with lambda/2-spacing was used. Data is obtained using a single element as the transmitting aperture and all 128 elements as the receiving aperture. A full SA sequence consisting of 128 emissions was simulated by gliding the active transmitting element...... weights for each frequency sub-band. As opposed to the conventional, Delay and Sum (DS) beamformer, this approach is dependent on the specific data. The performance of the proposed MV beamformer is tested on simulated synthetic aperture (SA) ultrasound data, obtained using Field II. For the simulations...... across the array. Data for 13 point targets and a circular cyst with a radius of 5 mm were simulated. The performance of the MV beamformer is compared to DS using boxcar weights and Hanning weights, and is quantified by the Full Width at Half Maximum (FWHM) and the peak-side-lobe level (PSL). Single...

  7. Framed bit error rate testing for 100G ethernet equipment

    DEFF Research Database (Denmark)

    Rasmussen, Anders; Ruepp, Sarah Renée; Berger, Michael Stübert

    2010-01-01

    rate. As the need for 100 Gigabit Ethernet equipment rises, so does the need for equipment, which can properly test these systems during development, deployment and use. This paper presents early results from a work-in-progress academia-industry collaboration project and elaborates on the challenges...

  8. Allometries of Maximum Growth Rate versus Body Mass at Maximum Growth Indicate That Non-Avian Dinosaurs Had Growth Rates Typical of Fast Growing Ectothermic Sauropsids

    Science.gov (United States)

    Werner, Jan; Griebeler, Eva Maria

    2014-01-01

    We tested if growth rates of recent taxa are unequivocally separated between endotherms and ectotherms, and compared these to dinosaurian growth rates. We therefore performed linear regression analyses on the log-transformed maximum growth rate against log-transformed body mass at maximum growth for extant altricial birds, precocial birds, eutherians, marsupials, reptiles, fishes and dinosaurs. Regression models of precocial birds (and fishes) strongly differed from Case’s study (1978), which is often used to compare dinosaurian growth rates to those of extant vertebrates. For all taxonomic groups, the slope of 0.75 expected from the Metabolic Theory of Ecology was statistically supported. To compare growth rates between taxonomic groups we therefore used regressions with this fixed slope and group-specific intercepts. On average, maximum growth rates of ectotherms were about 10 (reptiles) to 20 (fishes) times (in comparison to mammals) or even 45 (reptiles) to 100 (fishes) times (in comparison to birds) lower than in endotherms. While on average all taxa were clearly separated from each other, individual growth rates overlapped between several taxa and even between endotherms and ectotherms. Dinosaurs had growth rates intermediate between similar sized/scaled-up reptiles and mammals, but a much lower rate than scaled-up birds. All dinosaurian growth rates were within the range of extant reptiles and mammals, and were lower than those of birds. Under the assumption that growth rate and metabolic rate are indeed linked, our results suggest two alternative interpretations. Compared to other sauropsids, the growth rates of studied dinosaurs clearly indicate that they had an ectothermic rather than an endothermic metabolic rate. Compared to other vertebrate growth rates, the overall high variability in growth rates of extant groups and the high overlap between individual growth rates of endothermic and ectothermic extant species make it impossible to rule out either

  9. Allometries of maximum growth rate versus body mass at maximum growth indicate that non-avian dinosaurs had growth rates typical of fast growing ectothermic sauropsids.

    Science.gov (United States)

    Werner, Jan; Griebeler, Eva Maria

    2014-01-01

    We tested if growth rates of recent taxa are unequivocally separated between endotherms and ectotherms, and compared these to dinosaurian growth rates. We therefore performed linear regression analyses on the log-transformed maximum growth rate against log-transformed body mass at maximum growth for extant altricial birds, precocial birds, eutherians, marsupials, reptiles, fishes and dinosaurs. Regression models of precocial birds (and fishes) strongly differed from Case's study (1978), which is often used to compare dinosaurian growth rates to those of extant vertebrates. For all taxonomic groups, the slope of 0.75 expected from the Metabolic Theory of Ecology was statistically supported. To compare growth rates between taxonomic groups we therefore used regressions with this fixed slope and group-specific intercepts. On average, maximum growth rates of ectotherms were about 10 (reptiles) to 20 (fishes) times (in comparison to mammals) or even 45 (reptiles) to 100 (fishes) times (in comparison to birds) lower than in endotherms. While on average all taxa were clearly separated from each other, individual growth rates overlapped between several taxa and even between endotherms and ectotherms. Dinosaurs had growth rates intermediate between similar sized/scaled-up reptiles and mammals, but a much lower rate than scaled-up birds. All dinosaurian growth rates were within the range of extant reptiles and mammals, and were lower than those of birds. Under the assumption that growth rate and metabolic rate are indeed linked, our results suggest two alternative interpretations. Compared to other sauropsids, the growth rates of studied dinosaurs clearly indicate that they had an ectothermic rather than an endothermic metabolic rate. Compared to other vertebrate growth rates, the overall high variability in growth rates of extant groups and the high overlap between individual growth rates of endothermic and ectothermic extant species make it impossible to rule out either of

  10. Allometries of maximum growth rate versus body mass at maximum growth indicate that non-avian dinosaurs had growth rates typical of fast growing ectothermic sauropsids.

    Directory of Open Access Journals (Sweden)

    Jan Werner

    Full Text Available We tested if growth rates of recent taxa are unequivocally separated between endotherms and ectotherms, and compared these to dinosaurian growth rates. We therefore performed linear regression analyses on the log-transformed maximum growth rate against log-transformed body mass at maximum growth for extant altricial birds, precocial birds, eutherians, marsupials, reptiles, fishes and dinosaurs. Regression models of precocial birds (and fishes strongly differed from Case's study (1978, which is often used to compare dinosaurian growth rates to those of extant vertebrates. For all taxonomic groups, the slope of 0.75 expected from the Metabolic Theory of Ecology was statistically supported. To compare growth rates between taxonomic groups we therefore used regressions with this fixed slope and group-specific intercepts. On average, maximum growth rates of ectotherms were about 10 (reptiles to 20 (fishes times (in comparison to mammals or even 45 (reptiles to 100 (fishes times (in comparison to birds lower than in endotherms. While on average all taxa were clearly separated from each other, individual growth rates overlapped between several taxa and even between endotherms and ectotherms. Dinosaurs had growth rates intermediate between similar sized/scaled-up reptiles and mammals, but a much lower rate than scaled-up birds. All dinosaurian growth rates were within the range of extant reptiles and mammals, and were lower than those of birds. Under the assumption that growth rate and metabolic rate are indeed linked, our results suggest two alternative interpretations. Compared to other sauropsids, the growth rates of studied dinosaurs clearly indicate that they had an ectothermic rather than an endothermic metabolic rate. Compared to other vertebrate growth rates, the overall high variability in growth rates of extant groups and the high overlap between individual growth rates of endothermic and ectothermic extant species make it impossible to rule

  11. CASA-Mot technology: how results are affected by the frame rate and counting chamber.

    Science.gov (United States)

    Bompart, Daznia; García-Molina, Almudena; Valverde, Anthony; Caldeira, Carina; Yániz, Jesús; Núñez de Murga, Manuel; Soler, Carles

    2018-04-04

    For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20µm . The frame rate was previously limited by the hardware, although changes in the number of images collected could lead to significant variations in some kinematic parameters, mainly in curvilinear velocity (VCL). A frame rate of 60 frames s-1 is widely considered to be the minimum necessary for satisfactory results. However, the frame rate is species specific and must be defined in each experimental condition. In conclusion, we show that the optimal combination of frame rate and counting chamber type and depth should be defined for each species and experimental condition in order to obtain reliable results.

  12. Effects of the frame acquisition rate on the sensitivity of gastro-oesophageal reflux scintigraphy

    Science.gov (United States)

    Codreanu, I; Chamroonrat, W; Edwards, K

    2013-01-01

    Objective: To compare the sensitivity of gastro-oesophageal reflux (GOR) scintigraphy at 5-s and 60-s frame acquisition rates. Methods: GOR scintigraphy of 50 subjects (1 month–20 years old, mean 42 months) were analysed concurrently using 5-s and 60-s acquisition frames. Reflux episodes were graded as low if activity was detected in the distal half of the oesophagus and high if activity was detected in its upper half or in the oral cavity. For comparison purposes, detected GOR in any number of 5-s frames corresponding to one 60-s frame was counted as one episode. Results: A total of 679 episodes of GOR to the upper oesophagus were counted using a 5-s acquisition technique. Only 183 of such episodes were detected on 60-s acquisition images. To the lower oesophagus, a total of 1749 GOR episodes were detected using a 5-s acquisition technique and only 1045 episodes using 60-s acquisition frames (these also included the high-level GOR on 5-s frames counted as low level on 60-s acquisition frames). 10 patients had high-level GOR episodes that were detected only using a 5-s acquisition technique, leading to a different diagnosis in these patients. No correlation between the number of reflux episodes and the gastric emptying rates was noted. Conclusion: The 5-s frame acquisition technique is more sensitive than the 60-s frame acquisition technique for detecting both high- and low-level GOR. Advances in knowledge: Brief GOR episodes with a relatively low number of radioactive counts are frequently indistinguishable from intense background activity on 60-s acquisition frames. PMID:23520226

  13. Replication Rate, Framing, and Format Affect Attitudes and Decisions about Science Claims.

    Science.gov (United States)

    Barnes, Ralph M; Tobin, Stephanie J; Johnston, Heather M; MacKenzie, Noah; Taglang, Chelsea M

    2016-01-01

    A series of five experiments examined how the evaluation of a scientific finding was influenced by information about the number of studies that had successfully replicated the initial finding. The experiments also tested the impact of frame (negative, positive) and numeric format (percentage, natural frequency) on the evaluation of scientific findings. In Experiments 1 through 4, an attitude difference score served as the dependent measure, while a measure of choice served as the dependent measure in Experiment 5. Results from a diverse sample of 188 non-institutionalized U.S. adults (Experiment 2) and 730 undergraduate college students (Experiments 1, 3, and 4) indicated that attitudes became more positive as the replication rate increased and attitudes were more positive when the replication information was framed positively. The results also indicate that the manner in which replication rate was framed had a greater impact on attitude than the replication rate itself. The large effect for frame was attenuated somewhat when information about replication was presented in the form of natural frequencies rather than percentages. A fifth study employing 662 undergraduate college students in a task in which choice served as the dependent measure confirmed the framing effect and replicated the replication rate effect in the positive frame condition, but provided no evidence that the use of natural frequencies diminished the effect.

  14. Replication Rate, Framing, and Format Affect Attitudes and Decisions about Science Claims

    Directory of Open Access Journals (Sweden)

    Ralph M. Barnes

    2016-11-01

    Full Text Available A series of five experiments examined how the evaluation of a scientific finding was influenced by information about the number of studies that had successfully replicated the initial finding. The experiments also tested the impact of frame (negative, positive and numeric format (percentage, natural frequency on the evaluation of scientific findings. In Experiments 1 through 4, an attitude difference score served as the dependent measure, while a measure of choice served as the dependent measure in Experiment 5. Results from a diverse sample of 188 non-institutionalized U.S. adults (Experiment 2 and 730 undergraduate college students (Experiments 1, 3, and 4 indicated that attitudes became more positive as the replication rate increased and attitudes were more positive when the replication information was framed positively. The results also indicate that the manner in which replication rate was framed had a greater impact on attitude than the replication rate itself. The large effect for frame was attenuated somewhat when information about replication was presented in the form of natural frequencies rather than percentages. A fifth study employing 662 undergraduate college students in a task in which choice served as the dependent measure confirmed the framing effect and replicated the replication rate effect in the positive frame condition, but provided no evidence that the use of natural frequencies diminished the effect.

  15. Replication Rate, Framing, and Format Affect Attitudes and Decisions about Science Claims

    Science.gov (United States)

    Barnes, Ralph M.; Tobin, Stephanie J.; Johnston, Heather M.; MacKenzie, Noah; Taglang, Chelsea M.

    2016-01-01

    A series of five experiments examined how the evaluation of a scientific finding was influenced by information about the number of studies that had successfully replicated the initial finding. The experiments also tested the impact of frame (negative, positive) and numeric format (percentage, natural frequency) on the evaluation of scientific findings. In Experiments 1 through 4, an attitude difference score served as the dependent measure, while a measure of choice served as the dependent measure in Experiment 5. Results from a diverse sample of 188 non-institutionalized U.S. adults (Experiment 2) and 730 undergraduate college students (Experiments 1, 3, and 4) indicated that attitudes became more positive as the replication rate increased and attitudes were more positive when the replication information was framed positively. The results also indicate that the manner in which replication rate was framed had a greater impact on attitude than the replication rate itself. The large effect for frame was attenuated somewhat when information about replication was presented in the form of natural frequencies rather than percentages. A fifth study employing 662 undergraduate college students in a task in which choice served as the dependent measure confirmed the framing effect and replicated the replication rate effect in the positive frame condition, but provided no evidence that the use of natural frequencies diminished the effect. PMID:27920743

  16. TEKNIK ESTIMASI GERAK PENCARIAN PENUH DENGAN AKURASI SETENGAH PIKSEL UNTUK FRAME RATE UP CONVERSION VIDEO

    Directory of Open Access Journals (Sweden)

    ary satya prabhawa

    2014-10-01

    Full Text Available ABSTRAK Saat ini Teknologi video digital banyak digunakan pada aplikasi hiburan, contohnya adalah TV Digital dengan format HD. Dengan frame rate tinggi, pengkodean video akan menghasil laju bit lebih tinggi yaitu sampai 15 – 30 fps. Permasalahannya adalah kapasitas saluran transmisi memiliki kapasitas terbatas. Solusinya adalah menurunkan laju bit dengan menurunkan jumlah frame video ke penerima. Skema ini dikenal dengan Frame Rate Up-Conversion (FRUC video, dimana frame yang di encoder akan direkonstruksi kembali di decoder dengan membangkitkan frame intermediate (FI. FI dibangkitkan dengan teknik Motion Compensation Interpolation (MCI. Terkait dengan metode FRUC, penelitian ini mengajukan skema MCI unidirectional dengan pencarian gerak akurasi setengah piksel. Pada skema ini, sebuah motion vector (MV kandidat akan dicari di frame referensi, proses estimasi gerak dilakukan dengan menambah piksel sisipan diantara piksel eksisting. Sasarannya adalah meningkatkan akurasi MV kandidat. Hasil simulasi menunjukkan bahwa metode yang diajukan lebih baik sampai sebesar masing – masing 3,21 dB dan 3,11 dB pada wilayah pencarian 7 dan 15 piksel dibandingkan dengan metode frame repetition untuk sekuen video foreman dan hall monitor.

  17. 5 CFR 9901.312 - Maximum rates of base salary and adjusted salary.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Maximum rates of base salary and adjusted salary. 9901.312 Section 9901.312 Administrative Personnel DEPARTMENT OF DEFENSE HUMAN RESOURCES....312 Maximum rates of base salary and adjusted salary. (a) Subject to § 9901.105, the Secretary may...

  18. 47 CFR 1.1507 - Rulemaking on maximum rates for attorney fees.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rulemaking on maximum rates for attorney fees... § 1.1507 Rulemaking on maximum rates for attorney fees. (a) If warranted by an increase in the cost of... types of proceedings), the Commission may adopt regulations providing that attorney fees may be awarded...

  19. Fluoroscopic dose reduction by acquisition frame rate reduction and image processing

    International Nuclear Information System (INIS)

    Fritz, S.L.; Mirvis, S.E.; Pals, S.O.

    1986-01-01

    A new design for fluoroscopic exposure reduction incorporates pulsed x-ray exposure, progressive scan video acquisition at frame rates below 30 Hz, interlaced video display at 30 Hz, and a video rate image processing. To evaluate this design, a variety of phantom systems have been developed to measure the impact of low frame rate pulsed digital fluoroscopy on the performance of several clinical tasks (e.g., catheter placement). The authors are currently using these phantoms with a digital fluoroscopy system using continuous x-ray, interlaced video acquisition and variable acquisition frame rate. The design of their target digital fluoroscopic system, sample image sequences, and the results of some preliminary phantom studies are reported

  20. Temporal framing and the hidden-zero effect: rate-dependent outcomes on delay discounting.

    Science.gov (United States)

    Naudé, Gideon P; Kaplan, Brent A; Reed, Derek D; Henley, Amy J; DiGennaro Reed, Florence D

    2018-05-01

    Recent research suggests that presenting time intervals as units (e.g., days) or as specific dates, can modulate the degree to which humans discount delayed outcomes. Another framing effect involves explicitly stating that choosing a smaller-sooner reward is mutually exclusive to receiving a larger-later reward, thus presenting choices as an extended sequence. In Experiment 1, participants (N = 201) recruited from Amazon Mechanical Turk completed the Monetary Choice Questionnaire in a 2 (delay framing) by 2 (zero framing) design. Regression suggested a main effect of delay, but not zero, framing after accounting for other demographic variables and manipulations. We observed a rate-dependent effect for the date-framing group, such that those with initially steep discounting exhibited greater sensitivity to the manipulation than those with initially shallow discounting. Subsequent analyses suggest these effects cannot be explained by regression to the mean. Experiment 2 addressed the possibility that the null effect of zero framing was due to within-subject exposure to the hidden- and explicit-zero conditions. A new Amazon Mechanical Turk sample completed the Monetary Choice Questionnaire in either hidden- or explicit-zero formats. Analyses revealed a main effect of reward magnitude, but not zero framing, suggesting potential limitations to the generality of the hidden-zero effect. © 2018 Society for the Experimental Analysis of Behavior.

  1. The scaling of maximum and basal metabolic rates of mammals and birds

    Science.gov (United States)

    Barbosa, Lauro A.; Garcia, Guilherme J. M.; da Silva, Jafferson K. L.

    2006-01-01

    Allometric scaling is one of the most pervasive laws in biology. Its origin, however, is still a matter of dispute. Recent studies have established that maximum metabolic rate scales with an exponent larger than that found for basal metabolism. This unpredicted result sets a challenge that can decide which of the concurrent hypotheses is the correct theory. Here, we show that both scaling laws can be deduced from a single network model. Besides the 3/4-law for basal metabolism, the model predicts that maximum metabolic rate scales as M, maximum heart rate as M, and muscular capillary density as M, in agreement with data.

  2. Increased Frame Rate for Plane Wave Imaging Without Loss of Image Quality

    DEFF Research Database (Denmark)

    Jensen, Jonas; Stuart, Matthias Bo; Jensen, Jørgen Arendt

    2015-01-01

    Clinical applications of plane wave imaging necessitate the creation of high-quality images with the highest possible frame rate for improved blood flow tracking and anatomical imaging. However, linear array transducers create grating lobe artefacts, which degrade the image quality especially...... in the near field for λ-pitch transducers. Artefacts can only partly be suppressed by increasing the number of emissions, and this paper demonstrates how the frame rate can be increased without loss of image quality by using λ/2-pitch transducers. The number of emissions and steering angles are optimized...

  3. 13 CFR 107.845 - Maximum rate of amortization on Loans and Debt Securities.

    Science.gov (United States)

    2010-01-01

    ... ADMINISTRATION SMALL BUSINESS INVESTMENT COMPANIES Financing of Small Businesses by Licensees Structuring Licensee's Financing of An Eligible Small Business: Terms and Conditions of Financing § 107.845 Maximum... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Maximum rate of amortization on...

  4. Application of high-frame-rate neutron radiography to steam explosion research

    International Nuclear Information System (INIS)

    Saito, Y.; Mishima, K.; Hibiki, T.; Yamamoto, A.; Sugimoto, J.; Moriyama, K.

    1999-01-01

    To understand the behavior of dispersed molten metal particles dropped into water during the premixing process of steam explosion, experiments were performed by using heated stainless-steel particles simulating dispersed molten metal particles. High-frame-rate neutron radiography was successfully employed for visualization and void fraction measurement. Visualization was conducted by dropping heated stainless-steel particle into heavy water filled in a rectangular tank with the particle diameter (6, 9, and 12 mm) and temperature (600 deg. C, 700 deg. C, 800 deg. C, and 1000 deg. C) as parameters. Steam generation due to direct contact of heated particle and heavy water was successfully visualized by the high-frame-rate neutron radiography at the recording speed of 500 frames/s. From void fraction measurement it was revealed that the amount of generated steam was in proportion to the particle size and temperature. It is suggested that the ambient liquid might be superheated by the particle-liquid contact

  5. [The maximum heart rate in the exercise test: the 220-age formula or Sheffield's table?].

    Science.gov (United States)

    Mesquita, A; Trabulo, M; Mendes, M; Viana, J F; Seabra-Gomes, R

    1996-02-01

    To determine in the maximum cardiac rate in exercise test of apparently healthy individuals may be more properly estimated through 220-age formula (Astrand) or the Sheffield table. Retrospective analysis of clinical history and exercises test of apparently healthy individuals submitted to cardiac check-up. Sequential sampling of 170 healthy individuals submitted to cardiac check-up between April 1988 and September 1992. Comparison of maximum cardiac rate of individuals studied by the protocols of Bruce and modified Bruce, in interrupted exercise test by fatigue, and with the estimated values by the formulae: 220-age versus Sheffield table. The maximum cardiac heart rate is similar with both protocols. This parameter in normal individuals is better predicted by the 220-age formula. The theoretic maximum cardiac heart rate determined by 220-age formula should be recommended for a healthy, and for this reason the Sheffield table has been excluded from our clinical practice.

  6. New England observed and predicted August stream/river temperature maximum daily rate of change points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted August stream/river temperature maximum negative rate of change in New England based on a...

  7. Frequency-locked pulse sequencer for high-frame-rate monochromatic tissue motion imaging.

    Science.gov (United States)

    Azar, Reza Zahiri; Baghani, Ali; Salcudean, Septimiu E; Rohling, Robert

    2011-04-01

    To overcome the inherent low frame rate of conventional ultrasound, we have previously presented a system that can be implemented on conventional ultrasound scanners for high-frame-rate imaging of monochromatic tissue motion. The system employs a sector subdivision technique in the sequencer to increase the acquisition rate. To eliminate the delays introduced during data acquisition, a motion phase correction algorithm has also been introduced to create in-phase displacement images. Previous experimental results from tissue- mimicking phantoms showed that the system can achieve effective frame rates of up to a few kilohertz on conventional ultrasound systems. In this short communication, we present a new pulse sequencing strategy that facilitates high-frame-rate imaging of monochromatic motion such that the acquired echo signals are inherently in-phase. The sequencer uses the knowledge of the excitation frequency to synchronize the acquisition of the entire imaging plane to that of an external exciter. This sequencing approach eliminates any need for synchronization or phase correction and has applications in tissue elastography, which we demonstrate with tissue-mimicking phantoms. © 2011 IEEE

  8. Maximum production rate optimization for sulphuric acid decomposition process in tubular plug-flow reactor

    International Nuclear Information System (INIS)

    Wang, Chao; Chen, Lingen; Xia, Shaojun; Sun, Fengrui

    2016-01-01

    A sulphuric acid decomposition process in a tubular plug-flow reactor with fixed inlet flow rate and completely controllable exterior wall temperature profile and reactants pressure profile is studied in this paper by using finite-time thermodynamics. The maximum production rate of the aimed product SO 2 and the optimal exterior wall temperature profile and reactants pressure profile are obtained by using nonlinear programming method. Then the optimal reactor with the maximum production rate is compared with the reference reactor with linear exterior wall temperature profile and the optimal reactor with minimum entropy generation rate. The result shows that the production rate of SO 2 of optimal reactor with the maximum production rate has an increase of more than 7%. The optimization of temperature profile has little influence on the production rate while the optimization of reactants pressure profile can significantly increase the production rate. The results obtained may provide some guidelines for the design of real tubular reactors. - Highlights: • Sulphuric acid decomposition process in tubular plug-flow reactor is studied. • Fixed inlet flow rate and controllable temperature and pressure profiles are set. • Maximum production rate of aimed product SO 2 is obtained. • Corresponding optimal temperature and pressure profiles are derived. • Production rate of SO 2 of optimal reactor increases by 7%.

  9. Accurate Angle Estimator for High-Frame-rate 2-D Vector Flow Imaging

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Stuart, Matthias Bo; Lindskov Hansen, Kristoffer

    2016-01-01

    This paper presents a novel approach for estimating 2-D flow angles using a high-frame-rate ultrasound method. The angle estimator features high accuracy and low standard deviation (SD) over the full 360° range. The method is validated on Field II simulations and phantom measurements using...

  10. Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction

    NARCIS (Netherlands)

    Motaal, Abdallah G.; Coolen, Bram F.; Abdurrachim, Desiree; Castro, Rui M.; Prompers, Jeanine J.; Florack, Luc M. J.; Nicolay, Klaas; Strijkers, Gustav J.

    2013-01-01

    We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensi ng reconstruction. Key to our

  11. High frame rate synthetic aperture vector flow imaging for transthoracic echocardiography

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Stuart, Matthias Bo; Bechsgaard, Thor

    2016-01-01

    This work presents the first in vivo results of 2-D high frame rate vector velocity imaging for transthoracic cardiac imaging. Measurements are made on a healthy volunteer using the SARUS experimental ultrasound scanner connected to an intercostal phased-array probe. Two parasternal long-axis vie...

  12. Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate.

    Science.gov (United States)

    Lee, Ji Hyun; Kim, Jun; Kim, Minsu; Hwang, Jongmin; Hwang, You Mi; Kang, Joon-Won; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho

    2017-06-01

    Despite the technological advance in 3-dimensional (3D) mapping, radiation exposure during catheter ablation of atrial fibrillation (AF) continues to be a major concern in both patients and physicians. Previous studies reported substantial radiation exposure (7369-8690 cGy cm) during AF catheter ablation with fluoroscopic settings of 7.5 frames per second (FPS) under 3D mapping system guidance. We evaluated the efficacy and safety of a low-frame-rate fluoroscopy protocol for catheter ablation for AF.Retrospective analysis of data on 133 patients who underwent AF catheter ablation with 3-D electro-anatomic mapping at our institute from January 2014 to May 2015 was performed. Since January 2014, fluoroscopy frame rate of 4-FPS was implemented at our institute, which was further decreased to 2-FPS in September 2014. We compared the radiation exposure quantified as dose area product (DAP) and effective dose (ED) between the 4-FPS (n = 57) and 2-FPS (n = 76) groups.The 4-FPS group showed higher median DAP (599.9 cGy cm; interquartile range [IR], 371.4-1337.5 cGy cm vs. 392.0 cGy cm; IR, 289.7-591.4 cGy cm; P FPS group. No major procedure-related complications such as cardiac tamponade were observed in either group. Over follow-up durations of 331 ± 197 days, atrial tachyarrhythmia recurred in 20 patients (35.1%) in the 4-FPS group and in 27 patients (35.5%) in the 2-FPS group (P = .96). Kaplan-Meier survival analysis revealed no significant different between the 2 groups (log rank, P = .25).In conclusion, both the 4-FPS and 2-FPS settings were feasible and emitted a relatively low level of radiation compared with that historically reported for DAP in a conventional fluoroscopy setting.

  13. In-Vivo Synthetic Aperture and Plane Wave High Frame Rate Cardiac Imaging

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Jensen, Jonas; Brandt, Andreas Hjelm

    2014-01-01

    A comparison of synthetic aperture imaging using spherical and plane waves with low number of emission events is presented. For both wave types, a 90 degree sector is insonified using 15 emission events giving a frame rate of 200 frames per second. Field II simulations of point targets show simil.......43 for spherical and 0.70 for plane waves. All measures are well within FDA limits for cardiac imaging. In-vivo images of the heart of a healthy 28-year old volunteer are shown....

  14. Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Edstrom Jr., D. [Fermilab; Ruan, J. [Fermilab

    2016-10-09

    We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

  15. Novel driver method to improve ordinary CCD frame rate for high-speed imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Tong-Ding, E-mail: snuohui@126.com; Li, Bin-Kang; Yang, Shao-Hua; Guo, Ming-An; Yan, Ming

    2016-06-21

    The use of ordinary Charge-coupled-Device (CCD) imagers for the analysis of fast physical phenomenon is restricted because of the low-speed performance resulting from their long output times. Even though the form of Intensified-CCD (ICCD), coupled with a gated image intensifier, has extended their use for high speed imaging, the deficiency remains to be solved that ICDD could record only one image in a single shot. This paper presents a novel driver method designed to significantly improve the ordinary interline CCD burst frame rate for high-speed photography. This method is based on the use of vertical registers as storage, so that a small number of additional frames comprised of reduced-spatial-resolution images obtained via a specific sampling operation can be buffered. Hence, the interval time of the received series of images is related to the exposure and vertical transfer times only and, thus, the burst frame rate can be increased significantly. A prototype camera based on this method is designed as part of this study, exhibiting a burst rate of up to 250,000 frames per second (fps) and a capacity to record three continuous images. This device exhibits a speed enhancement of approximately 16,000 times compared with the conventional speed, with a spatial resolution reduction of only 1/4.

  16. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    OpenAIRE

    Soichiro Tsujino; Takashi Tomizaki

    2016-01-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinn...

  17. LASER: A Maximum Likelihood Toolkit for Detecting Temporal Shifts in Diversification Rates From Molecular Phylogenies

    Directory of Open Access Journals (Sweden)

    Daniel L. Rabosky

    2006-01-01

    Full Text Available Rates of species origination and extinction can vary over time during evolutionary radiations, and it is possible to reconstruct the history of diversification using molecular phylogenies of extant taxa only. Maximum likelihood methods provide a useful framework for inferring temporal variation in diversification rates. LASER is a package for the R programming environment that implements maximum likelihood methods based on the birth-death process to test whether diversification rates have changed over time. LASER contrasts the likelihood of phylogenetic data under models where diversification rates have changed over time to alternative models where rates have remained constant over time. Major strengths of the package include the ability to detect temporal increases in diversification rates and the inference of diversification parameters under multiple rate-variable models of diversification. The program and associated documentation are freely available from the R package archive at http://cran.r-project.org.

  18. Exercise-induced maximum metabolic rate scaled to body mass by ...

    African Journals Online (AJOL)

    user

    2016-10-27

    Oct 27, 2016 ... maximum aerobic metabolic rate (MMR) is proportional to the fractal extent ... metabolic rate with body mass can be obtained by taking body .... blood takes place. ..... MMR and BMR is that MMR is owing mainly to respiration in skeletal .... the spectra of surface area scaling strategies of cells and organisms:.

  19. Estimation of maximum credible atmospheric radioactivity concentrations and dose rates from nuclear tests

    International Nuclear Information System (INIS)

    Telegadas, K.

    1979-01-01

    A simple technique is presented for estimating maximum credible gross beta air concentrations from nuclear detonations in the atmosphere, based on aircraft sampling of radioactivity following each Chinese nuclear test from 1964 to 1976. The calculated concentration is a function of the total yield and fission yield, initial vertical radioactivity distribution, time after detonation, and rate of horizontal spread of the debris with time. calculated maximum credible concentrations are compared with the highest concentrations measured during aircraft sampling. The technique provides a reasonable estimate of maximum air concentrations from 1 to 10 days after a detonation. An estimate of the whole-body external gamma dose rate corresponding to the maximum credible gross beta concentration is also given. (author)

  20. Maximum Acceptable Vibrato Excursion as a Function of Vibrato Rate in Musicians and Non-musicians

    DEFF Research Database (Denmark)

    Vatti, Marianna; Santurette, Sébastien; Pontoppidan, Niels H.

    2014-01-01

    and, in most listeners, exhibited a peak at medium vibrato rates (5–7 Hz). Large across-subject variability was observed, and no significant effect of musical experience was found. Overall, most listeners were not solely sensitive to the vibrato excursion and there was a listener-dependent rate...... for which larger vibrato excursions were favored. The observed interaction between maximum excursion thresholds and vibrato rate may be due to the listeners’ judgments relying on cues provided by the rate of frequency changes (RFC) rather than excursion per se. Further studies are needed to evaluate......Human vibrato is mainly characterized by two parameters: vibrato extent and vibrato rate. These parameters have been found to exhibit an interaction both in physical recordings of singers’ voices and in listener’s preference ratings. This study was concerned with the way in which the maximum...

  1. Videopanorama Frame Rate Requirements Derived from Visual Discrimination of Deceleration During Simulated Aircraft Landing

    Science.gov (United States)

    Furnstenau, Norbert; Ellis, Stephen R.

    2015-01-01

    In order to determine the required visual frame rate (FR) for minimizing prediction errors with out-the-window video displays at remote/virtual airport towers, thirteen active air traffic controllers viewed high dynamic fidelity simulations of landing aircraft and decided whether aircraft would stop as if to be able to make a turnoff or whether a runway excursion would be expected. The viewing conditions and simulation dynamics replicated visual rates and environments of transport aircraft landing at small commercial airports. The required frame rate was estimated using Bayes inference on prediction errors by linear FRextrapolation of event probabilities conditional on predictions (stop, no-stop). Furthermore estimates were obtained from exponential model fits to the parametric and non-parametric perceptual discriminabilities d' and A (average area under ROC-curves) as dependent on FR. Decision errors are biased towards preference of overshoot and appear due to illusionary increase in speed at low frames rates. Both Bayes and A - extrapolations yield a framerate requirement of 35 game scores the model based d'(FR)-extrapolation exhibits the best agreement and indicates even higher FRmin > 40 Hz for minimizing decision errors. Definitive recommendations require further experiments with FR > 30 Hz.

  2. On the equivalence between the minimum entropy generation rate and the maximum conversion rate for a reactive system

    International Nuclear Information System (INIS)

    Bispo, Heleno; Silva, Nilton; Brito, Romildo; Manzi, João

    2013-01-01

    Highlights: • Minimum entropy generation (MEG) principle improved the reaction performance. • MEG rate and the maximum conversion equivalence have been analyzed. • Temperature and residence time are used to the domain establishment of MEG. • Satisfying the temperature and residence time relationship results a optimal performance. - Abstract: The analysis of the equivalence between the minimum entropy generation (MEG) rate and the maximum conversion rate for a reactive system is the main purpose of this paper. While being used as a strategy of optimization, the minimum entropy production was applied to the production of propylene glycol in a Continuous Stirred-Tank Reactor (CSTR) with a view to determining the best operating conditions, and under such conditions, a high conversion rate was found. The effects of the key variables and restrictions on the validity domain of MEG were investigated, which raises issues that are included within a broad discussion. The results from simulations indicate that from the chemical reaction standpoint a maximum conversion rate can be considered as equivalent to MEG. Such a result can be clearly explained by examining the classical Maxwell–Boltzmann distribution, where the molecules of the reactive system under the condition of the MEG rate present a distribution of energy with reduced dispersion resulting in a better quality of collision between molecules with a higher conversion rate

  3. Low reproducibility of maximum urinary flow rate determined by portable flowmetry

    NARCIS (Netherlands)

    Sonke, G. S.; Kiemeney, L. A.; Verbeek, A. L.; Kortmann, B. B.; Debruyne, F. M.; de la Rosette, J. J.

    1999-01-01

    To evaluate the reproducibility in maximum urinary flow rate (Qmax) in men with lower urinary tract symptoms (LUTSs) and to determine the number of flows needed to obtain a specified reliability in mean Qmax, 212 patients with LUTSs (mean age, 62 years) referred to the University Hospital Nijmegen,

  4. 19 CFR 212.07 - Rulemaking on maximum rates for attorney fees.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Rulemaking on maximum rates for attorney fees. 212.07 Section 212.07 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE IMPLEMENTATION OF THE EQUAL ACCESS TO JUSTICE ACT General Provisions...

  5. 7 CFR 4290.845 - Maximum rate of amortization on Loans and Debt Securities.

    Science.gov (United States)

    2010-01-01

    ...) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE RURAL BUSINESS INVESTMENT COMPANY (âRBICâ) PROGRAM Financing of Enterprises by RBICs Structuring Rbic Financing of Eligible Enterprises-Types of Financings § 4290.845 Maximum rate of amortization on Loans and Debt Securities. The...

  6. 30 CFR 75.601-3 - Short circuit protection; dual element fuses; current ratings; maximum values.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Short circuit protection; dual element fuses... Trailing Cables § 75.601-3 Short circuit protection; dual element fuses; current ratings; maximum values. Dual element fuses having adequate current-interrupting capacity shall meet the requirements for short...

  7. Distant Measurement of Plethysmographic Signal in Various Lighting Conditions Using Configurable Frame-Rate Camera

    Directory of Open Access Journals (Sweden)

    Przybyło Jaromir

    2016-12-01

    Full Text Available Videoplethysmography is currently recognized as a promising noninvasive heart rate measurement method advantageous for ubiquitous monitoring of humans in natural living conditions. Although the method is considered for application in several areas including telemedicine, sports and assisted living, its dependence on lighting conditions and camera performance is still not investigated enough. In this paper we report on research of various image acquisition aspects including the lighting spectrum, frame rate and compression. In the experimental part, we recorded five video sequences in various lighting conditions (fluorescent artificial light, dim daylight, infrared light, incandescent light bulb using a programmable frame rate camera and a pulse oximeter as the reference. For a video sequence-based heart rate measurement we implemented a pulse detection algorithm based on the power spectral density, estimated using Welch’s technique. The results showed that lighting conditions and selected video camera settings including compression and the sampling frequency influence the heart rate detection accuracy. The average heart rate error also varies from 0.35 beats per minute (bpm for fluorescent light to 6.6 bpm for dim daylight.

  8. MCP detector read out with a bare quad Timepix at kilohertz frame rates

    International Nuclear Information System (INIS)

    Vallerga, J; Tremsin, A; McPhate, J; Siegmund, O; Raffanti, R

    2011-01-01

    The existing Berkeley neutron sensitive MCP/Timepix hybrid detector has been very successful at demonstrating energy resolved spatial imaging with a single Timepix ASIC read out at a ∼ 30 Hz frame rate where each neutron's position and time (energy) is determined (X,Y,E). By increasing the detector format using a quad arrangement of Timepix readouts and increasing the frame rate to 1 kHz, we can increase our total event throughput by a factor of 120, thereby taking full advantage of the high fluxes of modern pulsed neutron sources (10 6 n cm -2 s -1 ). The key to this conversion is a new design for the ASIC readout, called the Berkeley Quad Timepix detector, consisting of 3 major subsystems. The first is a quad (2 x 2) bare Timepix ASIC board mounted directly behind the neutron sensitive MCPs in a hermetic vacuum enclosure with a sapphire window. The data from the Timepix ASICs flow to the second subsystem called the Interface board whose field programmable gate array (FPGA) rearranges and converts the digital bit stream to LVDS logic levels before sending downstream to the third subsystem, the Roach board. The Roach board is also FPGA based, and takes the data from all the ASICs and analyses the frames to extract information on the input events to pass on to the host PC. This paper describes in detail the hardware and firmware designs to accomplish this task.

  9. Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction.

    Science.gov (United States)

    Motaal, Abdallah G; Coolen, Bram F; Abdurrachim, Desiree; Castro, Rui M; Prompers, Jeanine J; Florack, Luc M J; Nicolay, Klaas; Strijkers, Gustav J

    2013-04-01

    We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensing reconstruction. Key to our approach is that we exploit the stochastic nature of the retrospective triggering acquisition scheme to produce an undersampled and random k-t space filling that allows for compressed sensing reconstruction and acceleration. As a standard, a self-gated FLASH sequence with a total acquisition time of 10 min was used to produce single-slice Cine movies of seven mouse hearts with 90 frames per cardiac cycle. Two times (2×) and three times (3×) k-t space undersampled Cine movies were produced from 2.5- and 1.5-min data acquisitions, respectively. The accelerated 90-frame Cine movies of mouse hearts were successfully reconstructed with a compressed sensing algorithm. The movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters, i.e. end-systolic and end-diastolic lumen surface areas and early-to-late filling rate ratio as a parameter to evaluate diastolic function, derived from the standard and accelerated Cine movies, were nearly identical. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Development of high-frame rate neutron radiography and quantitative measurement method for multiphase flow research

    International Nuclear Information System (INIS)

    Mishima, K.; Hibiki, T.

    1998-01-01

    Neutron radiography (NR) is one of the radiographic techniques which makes use of the difference in attenuation characteristics of neutrons in materials. Fluid measurement using the NR technique is a non-intrusive method which enables visualization of dynamic images of multiphase flow of opaque fluids and/or in a metallic duct. To apply the NR technique to multiphase flow research, high frame-rate NR was developed by combining up-to-date technologies for neutron sources, scintillator, high-speed video and image intensifier. This imaging system has several advantages such as a long recording time (up to 21 minutes), high-frame-rate (up to 1000 frames/s) imaging and there is no need for a triggering signal. Visualization studies of air-water two-phase flow in a metallic duct and molten metal-water interaction were performed at recording speeds of 250, 500 and 1000 frames/s. The qualities of the consequent images were sufficient to observe the flow pattern and behavior. It was also demonstrated that some characteristics of two-phase flow could be measured from these images in collaboration with image processing techniques. By utilizing geometrical information extracted from NR images, data on flow regime, bubble rise velocity, and wave height and interfacial area in annular flow were obtained. By utilizing attenuation characteristics of neutrons in materials, measurements of void profile and average void fraction were performed. It was confirmed that this new technique may have significant advantages both in visualizing and measuring high-speed fluid phenomena when other methods, such as an optical method and X-ray radiography, cannot be applied. (author)

  11. Application of high-frame-rate neutron radiography to fluid measurement

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi

    1997-01-01

    To apply Neutron radiography (NR) technique to multiphase flow research, high frame-rate NR was developed by assembling up-to-date technologies for neutron source, scintillator, high-speed video and image intensifier. This imaging system has several advantages such as a long recording time (up to 21 minutes), high-frame-rate (up to 1000 frames/s) imaging and no need for triggering signal. Visualization studies of air-water two-phase flow in a metallic duct and molten metal-water interaction were performed at the recording speeds of 250, 500 and 1000 frames/s. The qualities of those consecutive images were good enough to observe the flow pattern and behavior. It was demonstrated also that some characteristics of two-phase flow could be measured from those images in collaboration with image processing techniques. By utilizing geometrical information extracted from NR images, data on flow regime, rising velocity of bubbles, and wave height and interfacial area in annular flow could be obtained. By utilizing attenuation characteristics of neutrons in materials, measurements of void profile and average void fraction could be performed. For this purpose, a quantification method, i.e. Σ-scaling method, was proposed based upon the consideration on the effect of scattered neutrons. This method was tested against known void profiles and compared with existing measurement methods and a correlation for void fraction. It was confirmed that this new technique has significant advantages both in visualizing and measuring high-speed fluid phenomena. (J.P.N.)

  12. Disentangling the effects of alternation rate and maximum run length on judgments of randomness

    Directory of Open Access Journals (Sweden)

    Sabine G. Scholl

    2011-08-01

    Full Text Available Binary sequences are characterized by various features. Two of these characteristics---alternation rate and run length---have repeatedly been shown to influence judgments of randomness. The two characteristics, however, have usually been investigated separately, without controlling for the other feature. Because the two features are correlated but not identical, it seems critical to analyze their unique impact, as well as their interaction, so as to understand more clearly what influences judgments of randomness. To this end, two experiments on the perception of binary sequences orthogonally manipulated alternation rate and maximum run length (i.e., length of the longest run within the sequence. Results show that alternation rate consistently exerts a unique effect on judgments of randomness, but that the effect of alternation rate is contingent on the length of the longest run within the sequence. The effect of maximum run length was found to be small and less consistent. Together, these findings extend prior randomness research by integrating literature from the realms of perception, categorization, and prediction, as well as by showing the unique and joint effects of alternation rate and maximum run length on judgments of randomness.

  13. Conifers in cold environments synchronize maximum growth rate of tree-ring formation with day length.

    Science.gov (United States)

    Rossi, Sergio; Deslauriers, Annie; Anfodillo, Tommaso; Morin, Hubert; Saracino, Antonio; Motta, Renzo; Borghetti, Marco

    2006-01-01

    Intra-annual radial growth rates and durations in trees are reported to differ greatly in relation to species, site and environmental conditions. However, very similar dynamics of cambial activity and wood formation are observed in temperate and boreal zones. Here, we compared weekly xylem cell production and variation in stem circumference in the main northern hemisphere conifer species (genera Picea, Pinus, Abies and Larix) from 1996 to 2003. Dynamics of radial growth were modeled with a Gompertz function, defining the upper asymptote (A), x-axis placement (beta) and rate of change (kappa). A strong linear relationship was found between the constants beta and kappa for both types of analysis. The slope of the linear regression, which corresponds to the time at which maximum growth rate occurred, appeared to converge towards the summer solstice. The maximum growth rate occurred around the time of maximum day length, and not during the warmest period of the year as previously suggested. The achievements of photoperiod could act as a growth constraint or a limit after which the rate of tree-ring formation tends to decrease, thus allowing plants to safely complete secondary cell wall lignification before winter.

  14. Happiness and Arousal: Framing Happiness as Arousing Results in Lower Happiness Ratings for Older Adults

    Directory of Open Access Journals (Sweden)

    Par eBjalkebring

    2015-06-01

    Full Text Available Older adults have been shown to describe their happiness as lower in arousal when compared to younger adults. In addition, older adults prefer low arousal positive emotions over high arousal positive emotions in their daily lives. We experimentally investigated whether or not changing a few words in the description of happiness could influence a person’s rating of their happiness. We randomly assigned 193 participants, aged 22-92 years, to one of three conditions (high arousal, low arousal, or control. In line with previous findings, we found that older participants rated their happiness lower when framed as high in arousal (i.e., ecstatic, to be bursting with positive emotions and rated their happiness higher when framed as low in arousal (i.e., satisfied, to have a life filled with positive emotions. Younger adults remained uninfluenced by the manipulation. Our study demonstrates that arousal is essential to understanding ratings of happiness, and gives support to the notion that there are age differences in the preference for arousal.

  15. Rate maximum calculation of Dpa in CNA-II pressure vessel

    International Nuclear Information System (INIS)

    Mascitti, J. A

    2012-01-01

    The maximum dpa rate was calculated for the reactor in the following state: fresh fuel, no Xenon, a Boron concentration of 15.3 ppm, critical state, its control rods in the criticality position, hot, at full power (2160 MW). It was determined that the maximum dpa rate under such conditions is 3.54(2)x10 12 s -1 and it is located in the positions corresponding to θ=210 o in the azimuthal direction, and z=20 cm and -60 cm respectively in the axial direction, considering the calculation mesh centered at half height of the fuel element (FE) active length. The dpa rate spectrum was determined as well as the contribution to it for 4 energy groups: a thermal group, two epithermal groups and a fast one. The maximum dpa rate considering the photo-neutrons production from (γ, n) reaction in the heavy water of coolant and moderator was 3.93(4)x10 12 s -1 that is 11% greater than the obtained without photo-neutrons. This verified significant difference between both cases, suggest that photo-neutrons in large heavy water reactors such as CNA-II should not be ignored. The maximum DPA rate in the first mm of the reactor pressure vessel was calculated too and it was obtained a value of 4.22(6)x10 12 s -1 . It should be added that the calculation was carried out with the reactor complete accurate model, with no approximations in spatial or energy variables. Each value has, between parentheses, a percentage relative error representing the statistical uncertainty due to the probabilistic Monte Carlo method used to estimate it. More representative values may be obtained with this method if equilibrium burn-up distribution is used (author)

  16. Using a Graphics Turing Test to Evaluate the Effect of Frame Rate and Motion Blur on Telepresence of Animated Objects

    DEFF Research Database (Denmark)

    Borg, Mathias; Johansen, Stine Schmieg; Krog, Kim Srirat

    2013-01-01

    A limited Graphics Turing Test is used to determine the frame rate that is required to achieve telepresence of an animated object. For low object velocities of 2.25 and 4.5 degrees of visual angle per second at 60 frames per second a rotating object with no added motion blur is able to pass the t...

  17. Fast maximum likelihood estimation of mutation rates using a birth-death process.

    Science.gov (United States)

    Wu, Xiaowei; Zhu, Hongxiao

    2015-02-07

    Since fluctuation analysis was first introduced by Luria and Delbrück in 1943, it has been widely used to make inference about spontaneous mutation rates in cultured cells. Under certain model assumptions, the probability distribution of the number of mutants that appear in a fluctuation experiment can be derived explicitly, which provides the basis of mutation rate estimation. It has been shown that, among various existing estimators, the maximum likelihood estimator usually demonstrates some desirable properties such as consistency and lower mean squared error. However, its application in real experimental data is often hindered by slow computation of likelihood due to the recursive form of the mutant-count distribution. We propose a fast maximum likelihood estimator of mutation rates, MLE-BD, based on a birth-death process model with non-differential growth assumption. Simulation studies demonstrate that, compared with the conventional maximum likelihood estimator derived from the Luria-Delbrück distribution, MLE-BD achieves substantial improvement on computational speed and is applicable to arbitrarily large number of mutants. In addition, it still retains good accuracy on point estimation. Published by Elsevier Ltd.

  18. Methodological aspects of crossover and maximum fat-oxidation rate point determination.

    Science.gov (United States)

    Michallet, A-S; Tonini, J; Regnier, J; Guinot, M; Favre-Juvin, A; Bricout, V; Halimi, S; Wuyam, B; Flore, P

    2008-11-01

    Indirect calorimetry during exercise provides two metabolic indices of substrate oxidation balance: the crossover point (COP) and maximum fat oxidation rate (LIPOXmax). We aimed to study the effects of the analytical device, protocol type and ventilatory response on variability of these indices, and the relationship with lactate and ventilation thresholds. After maximum exercise testing, 14 relatively fit subjects (aged 32+/-10 years; nine men, five women) performed three submaximum graded tests: one was based on a theoretical maximum power (tMAP) reference; and two were based on the true maximum aerobic power (MAP). Gas exchange was measured concomitantly using a Douglas bag (D) and an ergospirometer (E). All metabolic indices were interpretable only when obtained by the D reference method and MAP protocol. Bland and Altman analysis showed overestimation of both indices with E versus D. Despite no mean differences between COP and LIPOXmax whether tMAP or MAP was used, the individual data clearly showed disagreement between the two protocols. Ventilation explained 10-16% of the metabolic index variations. COP was correlated with ventilation (r=0.96, P<0.01) and the rate of increase in blood lactate (r=0.79, P<0.01), and LIPOXmax correlated with the ventilation threshold (r=0.95, P<0.01). This study shows that, in fit healthy subjects, the analytical device, reference used to build the protocol and ventilation responses affect metabolic indices. In this population, and particularly to obtain interpretable metabolic indices, we recommend a protocol based on the true MAP or one adapted to include the transition from fat to carbohydrate. The correlation between metabolic indices and lactate/ventilation thresholds suggests that shorter, classical maximum progressive exercise testing may be an alternative means of estimating these indices in relatively fit subjects. However, this needs to be confirmed in patients who have metabolic defects.

  19. Throughput Estimation Method in Burst ACK Scheme for Optimizing Frame Size and Burst Frame Number Appropriate to SNR-Related Error Rate

    Science.gov (United States)

    Ohteru, Shoko; Kishine, Keiji

    The Burst ACK scheme enhances effective throughput by reducing ACK overhead when a transmitter sends sequentially multiple data frames to a destination. IEEE 802.11e is one such example. The size of the data frame body and the number of burst data frames are important burst transmission parameters that affect throughput. The larger the burst transmission parameters are, the better the throughput under error-free conditions becomes. However, large data frame could reduce throughput under error-prone conditions caused by signal-to-noise ratio (SNR) deterioration. If the throughput can be calculated from the burst transmission parameters and error rate, the appropriate ranges of the burst transmission parameters could be narrowed down, and the necessary buffer size for storing transmit data or received data temporarily could be estimated. In this paper, we present a method that features a simple algorithm for estimating the effective throughput from the burst transmission parameters and error rate. The calculated throughput values agree well with the measured ones for actual wireless boards based on the IEEE 802.11-based original MAC protocol. We also calculate throughput values for larger values of the burst transmission parameters outside the assignable values of the wireless boards and find the appropriate values of the burst transmission parameters.

  20. Void Fraction Measurement in Subcooled-Boiling Flow Using High-Frame-Rate Neutron Radiography

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Akimoto, Hajime; Hibiki, Takashi; Mishima, Kaichiro

    2001-01-01

    A high-frame-rate neutron radiography (NR) technique was applied to measure the void fraction distribution in forced-convective subcooled-boiling flow. The focus was experimental technique and error estimation of the high-frame-rate NR. The results of void fraction measurement in the boiling flow were described. Measurement errors on instantaneous and time-averaged void fractions were evaluated experimentally and analytically. Measurement errors were within 18 and 2% for instantaneous void fraction (measurement time is 0.89 ms), and time-averaged void fraction, respectively. The void fraction distribution of subcooled boiling was measured using atmospheric-pressure water in rectangular channels with channel width 30 mm, heated length 100 mm, channel gap 3 and 5 mm, inlet water subcooling from 10 to 30 K, and mass velocity ranging from 240 to 2000 kg/(m 2 .s). One side of the channel was heated homogeneously. Instantaneous void fraction and time-averaged void fraction distribution were measured parametrically. The effects of flow parameters on void fraction were investigated

  1. Stand-alone front-end system for high- frequency, high-frame-rate coded excitation ultrasonic imaging.

    Science.gov (United States)

    Park, Jinhyoung; Hu, Changhong; Shung, K Kirk

    2011-12-01

    A stand-alone front-end system for high-frequency coded excitation imaging was implemented to achieve a wider dynamic range. The system included an arbitrary waveform amplifier, an arbitrary waveform generator, an analog receiver, a motor position interpreter, a motor controller and power supplies. The digitized arbitrary waveforms at a sampling rate of 150 MHz could be programmed and converted to an analog signal. The pulse was subsequently amplified to excite an ultrasound transducer, and the maximum output voltage level achieved was 120 V(pp). The bandwidth of the arbitrary waveform amplifier was from 1 to 70 MHz. The noise figure of the preamplifier was less than 7.7 dB and the bandwidth was 95 MHz. Phantoms and biological tissues were imaged at a frame rate as high as 68 frames per second (fps) to evaluate the performance of the system. During the measurement, 40-MHz lithium niobate (LiNbO(3)) single-element lightweight (<;0.28 g) transducers were utilized. The wire target measure- ment showed that the -6-dB axial resolution of a chirp-coded excitation was 50 μm and lateral resolution was 120 μm. The echo signal-to-noise ratios were found to be 54 and 65 dB for the short burst and coded excitation, respectively. The contrast resolution in a sphere phantom study was estimated to be 24 dB for the chirp-coded excitation and 15 dB for the short burst modes. In an in vivo study, zebrafish and mouse hearts were imaged. Boundaries of the zebrafish heart in the image could be differentiated because of the low-noise operation of the implemented system. In mouse heart images, valves and chambers could be readily visualized with the coded excitation.

  2. Clinical evaluation of a simple uroflowmeter for categorization of maximum urinary flow rate

    Directory of Open Access Journals (Sweden)

    Simon Pridgeon

    2007-01-01

    Full Text Available Objective: To evaluate the accuracy and diagnostic usefulness of a disposable flowmeter consisting of a plastic funnel with a spout divided into three chambers. Materials and Methods: Men with lower urinary tract symptoms (LUTS voided sequentially into a standard flowmeter and the funnel device recording maximum flow rate (Q max and voided volume (V void . The device was precalibrated such that filling of the bottom, middle and top chambers categorized maximum input flows as 15 ml s -1 respectively. Subjects who agreed to use the funnel device at home obtained readings of flow category and V void twice daily for seven days. Results: A single office reading in 46 men using the device showed good agreement with standard measurement of Q max for V void > 150 ml (Kappa = 0.68. All 14 men whose void reached the top chamber had standard Q max > 15 ml s -1 (PPV = 100%, NPV = 72% whilst eight of 12 men whose void remained in the bottom chamber had standard Q max < 10 ml s -1 (PPV = 70%, NPV = 94%. During multiple home use by 14 men the device showed moderate repeatability (Kappa = 0.58 and correctly categorized Q max in comparison to standard measurement for 12 (87% men. Conclusions: This study suggests that the device has sufficient accuracy and reliability for initial flow rate assessment in men with LUTS. The device can provide a single measurement or alternatively multiple home measurements to categorize men with Q max < 15 ml s -1 .

  3. Very high frame rate volumetric integration of depth images on mobile devices.

    Science.gov (United States)

    Kähler, Olaf; Adrian Prisacariu, Victor; Yuheng Ren, Carl; Sun, Xin; Torr, Philip; Murray, David

    2015-11-01

    Volumetric methods provide efficient, flexible and simple ways of integrating multiple depth images into a full 3D model. They provide dense and photorealistic 3D reconstructions, and parallelised implementations on GPUs achieve real-time performance on modern graphics hardware. To run such methods on mobile devices, providing users with freedom of movement and instantaneous reconstruction feedback, remains challenging however. In this paper we present a range of modifications to existing volumetric integration methods based on voxel block hashing, considerably improving their performance and making them applicable to tablet computer applications. We present (i) optimisations for the basic data structure, and its allocation and integration; (ii) a highly optimised raycasting pipeline; and (iii) extensions to the camera tracker to incorporate IMU data. In total, our system thus achieves frame rates up 47 Hz on a Nvidia Shield Tablet and 910 Hz on a Nvidia GTX Titan XGPU, or even beyond 1.1 kHz without visualisation.

  4. High Frame-Rate Blood Vector Velocity Imaging Using Plane Waves: Simulations and Preliminary Experiments

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Hansen, Kristoffer Lindskov

    2008-01-01

    ) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program......, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common...... carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow...

  5. Rate of alignment and communication using quantum systems in the absence of a shared frame of reference

    Science.gov (United States)

    Skotiniotis, Michael

    Quantum information theory is concerned with the storage, transmission, and manipulation of information that is represented in the degrees of freedom of quantum systems. These degrees of freedom are described relative to an external frame of reference. The lack of a requisite frame of reference imposes restrictions on the types of states quantum systems can be prepared in and the type of operations that can be performed on quantum systems. This thesis is concerned with the communication between two parties that lack a shared frame of reference. Specifically, I introduce a protocol whereby the parties can align their respective frames of reference, and a protocol for communicating quantum information in a reference frame independent manner. Using the accessible information to quantify the success of a reference frame alignment protocol I propose a new measure—the alignment rate—for quantifying the ability of a quantum state to stand in place of a classical frame of reference. I show that for the case where Alice and Bob lack a shared frame of reference associated with the groups G = U(1) and G = ZM (the finite cyclic group of M elements), the alignment rate is equal to the regularized, linearized G-asymmetry. The latter is a unique measure of the frameness of a quantum state and my result provides an operational interpretation of the G-asymmetry that was thus far lacking. In addition, I show that the alignment rate for finite cyclic groups of more than three elements is super-additive under the tensor product of two distinct pure quantum states. The latter is, to my knowledge, the first instance of a regularized quantity that exhibits super-additivity. In addition, I propose a reference-frame-independent protocol for communicating quantum information in the absence of a shared frame of reference associated with a general finite group G. The protocol transmits m logical qudits using r + m physical qudits prepared in a specific state that is reference-frame

  6. High frame rate synthetic aperture vector flow imaging for transthoracic echocardiography

    Science.gov (United States)

    Villagómez-Hoyos, Carlos A.; Stuart, Matthias B.; Bechsgaard, Thor; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt

    2016-04-01

    This work presents the first in vivo results of 2-D high frame rate vector velocity imaging for transthoracic cardiac imaging. Measurements are made on a healthy volunteer using the SARUS experimental ultrasound scanner connected to an intercostal phased-array probe. Two parasternal long-axis view (PLAX) are obtained, one centred at the aortic valve and another centred at the left ventricle. The acquisition sequence was composed of 3 diverging waves for high frame rate synthetic aperture flow imaging. For verification a phantom measurement is performed on a transverse straight 5 mm diameter vessel at a depth of 100 mm in a tissue-mimicking phantom. A flow pump produced a 2 ml/s constant flow with a peak velocity of 0.2 m/s. The average estimated flow angle in the ROI was 86.22° +/- 6.66° with a true flow angle of 90°. A relative velocity bias of -39% with a standard deviation of 13% was found. In-vivo acquisitions show complex flow patterns in the heart. In the aortic valve view, blood is seen exiting the left ventricle cavity through the aortic valve into the aorta during the systolic phase of the cardiac cycle. In the left ventricle view, blood flow is seen entering the left ventricle cavity through the mitral valve and splitting in two ways when approximating the left ventricle wall. The work presents 2-D velocity estimates on the heart from a non-invasive transthoracic scan. The ability of the method detecting flow regardless of the beam angle could potentially reveal a more complete view of the flow patterns presented on the heart.

  7. SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Yip, S; Rottmann, J; Berbeco, R [Brigham and Women' s Hospital, Boston, MA (United States)

    2014-06-01

    Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the

  8. SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking

    International Nuclear Information System (INIS)

    Yip, S; Rottmann, J; Berbeco, R

    2014-01-01

    Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the

  9. Framing the conversation: use of PRECIS-2 ratings to advance understanding of pragmatic trial design domains.

    Science.gov (United States)

    Lipman, Paula Darby; Loudon, Kirsty; Dluzak, Leanora; Moloney, Rachael; Messner, Donna; Stoney, Catherine M

    2017-11-10

    There continues to be debate about what constitutes a pragmatic trial and how it is distinguished from more traditional explanatory trials. The NIH Pragmatic Trials Collaborative Project, which includes five trials and a coordinating unit, has adopted the Pragmatic-Explanatory Continuum Indicator Summary (PRECIS-2) instrument. The purpose of the study was to collect PRECIS-2 ratings at two points in time to assess whether the tool was sensitive to change in trial design, and to explore with investigators the rationale for rating shifts. A mixed-methods design included sequential collection and analysis of quantitative data (PRECIS-2 ratings) and qualitative data. Ratings were collected at two annual, in-person project meetings, and subsequent interviews conducted with investigators were recorded, transcribed, and coded using NVivo 11 Pro for Windows. Rating shifts were coded as either (1) actual change (reflects a change in procedure or protocol), (2) primarily a rating shift reflecting rater variability, or (3) themes that reflect important concepts about the tool and/or pragmatic trial design. Based on PRECIS-2 ratings, each trial was highly pragmatic at the planning phase and remained so 1 year later in the early phases of trial implementation. Over half of the 45 paired ratings for the nine PRECIS-2 domains indicated a rating change from Time 1 to Time 2 (N = 24, 53%). Of the 24 rating changes, only three represented a true change in the design of the trial. Analysis of rationales for rating shifts identified critical themes associated with the tool or pragmatic trial design more generally. Each trial contributed one or more relevant comments, with Eligibility, Flexibility of Adherence, and Follow-up each accounting for more than one. PRECIS-2 has proved useful for "framing the conversation" about trial design among members of the Pragmatic Trials Collaborative Project. Our findings suggest that design elements assessed by the PRECIS-2 tool may represent

  10. Maximum heart rate in brown trout (Salmo trutta fario) is not limited by firing rate of pacemaker cells.

    Science.gov (United States)

    Haverinen, Jaakko; Abramochkin, Denis V; Kamkin, Andre; Vornanen, Matti

    2017-02-01

    Temperature-induced changes in cardiac output (Q̇) in fish are largely dependent on thermal modulation of heart rate (f H ), and at high temperatures Q̇ collapses due to heat-dependent depression of f H This study tests the hypothesis that firing rate of sinoatrial pacemaker cells sets the upper thermal limit of f H in vivo. To this end, temperature dependence of action potential (AP) frequency of enzymatically isolated pacemaker cells (pacemaker rate, f PM ), spontaneous beating rate of isolated sinoatrial preparations (f SA ), and in vivo f H of the cold-acclimated (4°C) brown trout (Salmo trutta fario) were compared under acute thermal challenges. With rising temperature, f PM steadily increased because of the acceleration of diastolic depolarization and shortening of AP duration up to the break point temperature (T BP ) of 24.0 ± 0.37°C, at which point the electrical activity abruptly ceased. The maximum f PM at T BP was much higher [193 ± 21.0 beats per minute (bpm)] than the peak f SA (94.3 ± 6.0 bpm at 24.1°C) or peak f H (76.7 ± 2.4 at 15.7 ± 0.82°C) (P brown trout in vivo. Copyright © 2017 the American Physiological Society.

  11. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    Science.gov (United States)

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-05-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.

  12. Improving Bayesian credibility intervals for classifier error rates using maximum entropy empirical priors.

    Science.gov (United States)

    Gustafsson, Mats G; Wallman, Mikael; Wickenberg Bolin, Ulrika; Göransson, Hanna; Fryknäs, M; Andersson, Claes R; Isaksson, Anders

    2010-06-01

    Successful use of classifiers that learn to make decisions from a set of patient examples require robust methods for performance estimation. Recently many promising approaches for determination of an upper bound for the error rate of a single classifier have been reported but the Bayesian credibility interval (CI) obtained from a conventional holdout test still delivers one of the tightest bounds. The conventional Bayesian CI becomes unacceptably large in real world applications where the test set sizes are less than a few hundred. The source of this problem is that fact that the CI is determined exclusively by the result on the test examples. In other words, there is no information at all provided by the uniform prior density distribution employed which reflects complete lack of prior knowledge about the unknown error rate. Therefore, the aim of the study reported here was to study a maximum entropy (ME) based approach to improved prior knowledge and Bayesian CIs, demonstrating its relevance for biomedical research and clinical practice. It is demonstrated how a refined non-uniform prior density distribution can be obtained by means of the ME principle using empirical results from a few designs and tests using non-overlapping sets of examples. Experimental results show that ME based priors improve the CIs when employed to four quite different simulated and two real world data sets. An empirically derived ME prior seems promising for improving the Bayesian CI for the unknown error rate of a designed classifier. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Maximum type 1 error rate inflation in multiarmed clinical trials with adaptive interim sample size modifications.

    Science.gov (United States)

    Graf, Alexandra C; Bauer, Peter; Glimm, Ekkehard; Koenig, Franz

    2014-07-01

    Sample size modifications in the interim analyses of an adaptive design can inflate the type 1 error rate, if test statistics and critical boundaries are used in the final analysis as if no modification had been made. While this is already true for designs with an overall change of the sample size in a balanced treatment-control comparison, the inflation can be much larger if in addition a modification of allocation ratios is allowed as well. In this paper, we investigate adaptive designs with several treatment arms compared to a single common control group. Regarding modifications, we consider treatment arm selection as well as modifications of overall sample size and allocation ratios. The inflation is quantified for two approaches: a naive procedure that ignores not only all modifications, but also the multiplicity issue arising from the many-to-one comparison, and a Dunnett procedure that ignores modifications, but adjusts for the initially started multiple treatments. The maximum inflation of the type 1 error rate for such types of design can be calculated by searching for the "worst case" scenarios, that are sample size adaptation rules in the interim analysis that lead to the largest conditional type 1 error rate in any point of the sample space. To show the most extreme inflation, we initially assume unconstrained second stage sample size modifications leading to a large inflation of the type 1 error rate. Furthermore, we investigate the inflation when putting constraints on the second stage sample sizes. It turns out that, for example fixing the sample size of the control group, leads to designs controlling the type 1 error rate. © 2014 The Author. Biometrical Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Petroleum production at Maximum Efficient Rate Naval Petroleum Reserve No. 1 (Elk Hills), Kern County, California

    International Nuclear Information System (INIS)

    1993-07-01

    This document provides an analysis of the potential impacts associated with the proposed action, which is continued operation of Naval Petroleum Reserve No. I (NPR-1) at the Maximum Efficient Rate (MER) as authorized by Public law 94-258, the Naval Petroleum Reserves Production Act of 1976 (Act). The document also provides a similar analysis of alternatives to the proposed action, which also involve continued operations, but under lower development scenarios and lower rates of production. NPR-1 is a large oil and gas field jointly owned and operated by the federal government and Chevron U.SA Inc. (CUSA) pursuant to a Unit Plan Contract that became effective in 1944; the government's interest is approximately 78% and CUSA's interest is approximately 22%. The government's interest is under the jurisdiction of the United States Department of Energy (DOE). The facility is approximately 17,409 acres (74 square miles), and it is located in Kern County, California, about 25 miles southwest of Bakersfield and 100 miles north of Los Angeles in the south central portion of the state. The environmental analysis presented herein is a supplement to the NPR-1 Final Environmental Impact Statement of that was issued by DOE in 1979 (1979 EIS). As such, this document is a Supplemental Environmental Impact Statement (SEIS)

  15. Riding the Plane Wave: Considerations for In Vivo Study Designs Employing High Frame Rate Ultrasound

    Directory of Open Access Journals (Sweden)

    Jason S. Au

    2018-02-01

    Full Text Available Advancements in diagnostic ultrasound have allowed for a rapid expansion of the quantity and quality of non-invasive information that clinical researchers can acquire from cardiovascular physiology. The recent emergence of high frame rate ultrasound (HiFRUS is the next step in the quantification of complex blood flow behavior, offering angle-independent, high temporal resolution data in normal physiology and clinical cases. While there are various HiFRUS methods that have been tested and validated in simulations and in complex flow phantoms, there is a need to expand the field into more rigorous in vivo testing for clinical relevance. In this tutorial, we briefly outline the major advances in HiFRUS, and discuss practical considerations of participant preparation, experimental design, and human measurement, while also providing an example of how these frameworks can be immediately applied to in vivo research questions. The considerations put forward in this paper aim to set a realistic framework for research labs which use HiFRUS to commence the collection of human data for basic science, as well as for preliminary clinical research questions.

  16. Noiseless imaging detector for adaptive optics with kHz frame rates

    CERN Document Server

    Vallerga, J V; Mikulec, Bettina; Tremsin, A; Clark, Allan G; Siegmund, O H W; CERN. Geneva

    2004-01-01

    A new hybrid optical detector is described that has many of the attributes desired for the next generation AO wavefront sensors. The detector consists of a proximity focused MCP read out by four multi-pixel application specific integrated circuit (ASIC) chips developed at CERN (â€ワMedipix2”) with individual pixels that amplify, discriminate and count input events. The detector has 512 x 512 pixels, zero readout noise (photon counting) and can be read out at 1 kHz frame rates. The Medipix2 readout chips can be electronically shuttered down to a temporal window of a few microseconds with an accuracy of 10 nanoseconds. When used in a Shack-Hartman style wavefront sensor, it should be able to centroid approximately 5000 spots using 7 x 7 pixel sub-apertures resulting in very linear, off-null error correction terms. The quantum efficiency depends on the optical photocathode chosen for the bandpass of interest. A three year development effort for this detector technology has just been funded as part of the...

  17. Identification of speech transients using variable frame rate analysis and wavelet packets.

    Science.gov (United States)

    Rasetshwane, Daniel M; Boston, J Robert; Li, Ching-Chung

    2006-01-01

    Speech transients are important cues for identifying and discriminating speech sounds. Yoo et al. and Tantibundhit et al. were successful in identifying speech transients and, emphasizing them, improving the intelligibility of speech in noise. However, their methods are computationally intensive and unsuitable for real-time applications. This paper presents a method to identify and emphasize speech transients that combines subband decomposition by the wavelet packet transform with variable frame rate (VFR) analysis and unvoiced consonant detection. The VFR analysis is applied to each wavelet packet to define a transitivity function that describes the extent to which the wavelet coefficients of that packet are changing. Unvoiced consonant detection is used to identify unvoiced consonant intervals and the transitivity function is amplified during these intervals. The wavelet coefficients are multiplied by the transitivity function for that packet, amplifying the coefficients localized at times when they are changing and attenuating coefficients at times when they are steady. Inverse transform of the modified wavelet packet coefficients produces a signal corresponding to speech transients similar to the transients identified by Yoo et al. and Tantibundhit et al. A preliminary implementation of the algorithm runs more efficiently.

  18. Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation

    Science.gov (United States)

    Koch, A.; Hart, M.; Nicholls, T.; Angelsen, C.; Coughlan, J.; French, M.; Hauf, S.; Kuster, M.; Sztuk-Dambietz, J.; Turcato, M.; Carini, G. A.; Chollet, M.; Herrmann, S. C.; Lemke, H. T.; Nelson, S.; Song, S.; Weaver, M.; Zhu, D.; Meents, A.; Fischer, P.

    2013-11-01

    A MHz frame rate X-ray area detector (LPD — Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 μm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASIC's preamplifier provides relatively low noise at high speed which results in a high dynamic range of 105 photons over an energy range of 5-20 keV. Small scale prototypes of 32 × 256 pixels (LPD 2-Tile detector) and 256 × 256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 104 at 12 keV with a readout noise equivalent to < 1 photon rms in its most sensitive mode.

  19. Maximum Evaporation Rates of Water Droplets Approaching Obstacles in the Atmosphere Under Icing Conditions

    Science.gov (United States)

    Lowell, H. H.

    1953-01-01

    When a closed body or a duct envelope moves through the atmosphere, air pressure and temperature rises occur ahead of the body or, under ram conditions, within the duct. If cloud water droplets are encountered, droplet evaporation will result because of the air-temperature rise and the relative velocity between the droplet and stagnating air. It is shown that the solution of the steady-state psychrometric equation provides evaporation rates which are the maximum possible when droplets are entrained in air moving along stagnation lines under such conditions. Calculations are made for a wide variety of water droplet diameters, ambient conditions, and flight Mach numbers. Droplet diameter, body size, and Mach number effects are found to predominate, whereas wide variation in ambient conditions are of relatively small significance in the determination of evaporation rates. The results are essentially exact for the case of movement of droplets having diameters smaller than about 30 microns along relatively long ducts (length at least several feet) or toward large obstacles (wings), since disequilibrium effects are then of little significance. Mass losses in the case of movement within ducts will often be significant fractions (one-fifth to one-half) of original droplet masses, while very small droplets within ducts will often disappear even though the entraining air is not fully stagnated. Wing-approach evaporation losses will usually be of the order of several percent of original droplet masses. Two numerical examples are given of the determination of local evaporation rates and total mass losses in cases involving cloud droplets approaching circular cylinders along stagnation lines. The cylinders chosen were of 3.95-inch (10.0+ cm) diameter and 39.5-inch 100+ cm) diameter. The smaller is representative of icing-rate measurement cylinders, while with the larger will be associated an air-flow field similar to that ahead of an airfoil having a leading-edge radius

  20. New England observed and predicted August stream/river temperature maximum positive daily rate of change points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted August stream/river temperature maximum positive daily rate of change in New England based on a...

  1. New England observed and predicted July stream/river temperature maximum positive daily rate of change points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted July stream/river temperature maximum positive daily rate of change in New England based on a...

  2. New England observed and predicted July maximum negative stream/river temperature daily rate of change points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted July stream/river temperature maximum negative daily rate of change in New England based on a...

  3. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  4. The effect of frame rate on the ability of experienced gait analysts to identify characteristics of gait from closed circuit television footage.

    Science.gov (United States)

    Birch, Ivan; Vernon, Wesley; Burrow, Gordon; Walker, Jeremy

    2014-03-01

    Forensic gait analysis is increasingly being used as part of criminal investigations. A major issue is the quality of the closed circuit television (CCTV) footage used, particularly the frame rate which can vary from 25 frames per second to one frame every 4s. To date, no study has investigated the effect of frame rate on forensic gait analysis. A single subject was fitted with an ankle foot orthosis and recorded walking at 25 frames per second. 3D motion data were also collected, providing an absolute assessment of the gait characteristics. The CCTV footage was then edited to produce a set of eight additional pieces of footage, at various frame rates. Practitioners with knowledge of forensic gait analysis were recruited and instructed to record their observations regarding the characteristics of the subject's gait from the footage. They were sequentially sent web links to the nine pieces of footage, lowest frame rate first, and a simple observation recording form, over a period of 8 months. A sample-based Pearson product-moment correlation analysis of the results demonstrated a significant positive relationship between frame rate and scores (r=0.868, p=0.002). The results of this study show that frame rate affects the ability of experienced practitioners to identify characteristics of gait captured on CCTV footage. Every effort should therefore be made to ensure that CCTV footage likely to be used in criminal proceedings is captured at as high a frame rate as possible. © 2013.

  5. Framing car fuel efficiency : linearity heuristic for fuel consumption and fuel-efficiency ratings

    NARCIS (Netherlands)

    Schouten, T.M.; Bolderdijk, J.W.; Steg, L.

    2014-01-01

    People are sensitive to the way information on fuel efficiency is conveyed. When the fuel efficiency of cars is framed in terms of fuel per distance (FPD; e.g. l/100 km), instead of distance per units of fuel (DPF; e.g. km/l), people have a more accurate perception of potential fuel savings. People

  6. Replication Rate, Framing, and Format Affect Attitudes and Decisions about Science Claims

    OpenAIRE

    Barnes, Ralph M.; Tobin, Stephanie J.; Johnston, Heather M.; MacKenzie, Noah; Taglang, Chelsea M.

    2016-01-01

    A series of five experiments examined how the evaluation of a scientific finding was influenced by information about the number of studies that had successfully replicated the initial finding. The experiments also tested the impact of frame (negative, positive) and numeric format (percentage, natural frequency) on the evaluation of scientific findings. In Experiments 1 through 4, an attitude difference score served as the dependent measure, while a measure of choice served as the dependent me...

  7. 75 FR 52947 - Maximum Per Diem Rates for the Continental United States (CONUS)

    Science.gov (United States)

    2010-08-30

    ... per diem rate setting process enhances the government's ability to obtain policy-compliant lodging where it is needed. In conjunction with the annual lodging study, GSA identified five new non-standard... diem localities and updates the standard CONUS rate. The CONUS per diem rates prescribed in Bulletin 11...

  8. AEROSOL NUCLEATION AND GROWTH DURING LAMINAR TUBE FLOW: MAXIMUM SATURATIONS AND NUCLEATION RATES. (R827354C008)

    Science.gov (United States)

    An approximate method of estimating the maximum saturation, the nucleation rate, and the total number nucleated per second during the laminar flow of a hot vapour–gas mixture along a tube with cold walls is described. The basis of the approach is that the temperature an...

  9. High-frame-rate Imaging of a Carotid Bifurcation using a Low-complexity Velocity Estimation Approach

    DEFF Research Database (Denmark)

    di Ianni, Tommaso; Villagómez Hoyos, Carlos Armando; Ewertsen, Caroline

    2017-01-01

    In this paper, a 2-D vector flow imaging (VFI) method developed by combining synthetic aperture sequential beamforming and directional transverse oscillation is used to image a carotid bifurcation. Ninety-six beamformed lines are sent from the probe to the host system for each VFI frame, enabling...... the possibility of wireless transmission. The velocity is estimated using a relatively inexpensive 2-D phase-shift approach, and real-time performance can be achieved in mobile devices. However, high-frame-rate velocities can be obtained by sending the data to a cluster of computers. The objective of this study...... is to demonstrate the scalability of the method’s performance according to the needs of the user and the processing capabilities of the host system. In vivo measurements of a carotid bifurcation of a 54-year-old volunteer were conducted using a linear array transducer connected to the SARUS scanner. The velocities...

  10. Maximum rates of climate change are systematically underestimated in the geological record.

    Science.gov (United States)

    Kemp, David B; Eichenseer, Kilian; Kiessling, Wolfgang

    2015-11-10

    Recently observed rates of environmental change are typically much higher than those inferred for the geological past. At the same time, the magnitudes of ancient changes were often substantially greater than those established in recent history. The most pertinent disparity, however, between recent and geological rates is the timespan over which the rates are measured, which typically differ by several orders of magnitude. Here we show that rates of marked temperature changes inferred from proxy data in Earth history scale with measurement timespan as an approximate power law across nearly six orders of magnitude (10(2) to >10(7) years). This scaling reveals how climate signals measured in the geological record alias transient variability, even during the most pronounced climatic perturbations of the Phanerozoic. Our findings indicate that the true attainable pace of climate change on timescales of greatest societal relevance is underestimated in geological archives.

  11. A video event trigger for high frame rate, high resolution video technology

    Science.gov (United States)

    Williams, Glenn L.

    1991-12-01

    When video replaces film the digitized video data accumulates very rapidly, leading to a difficult and costly data storage problem. One solution exists for cases when the video images represent continuously repetitive 'static scenes' containing negligible activity, occasionally interrupted by short events of interest. Minutes or hours of redundant video frames can be ignored, and not stored, until activity begins. A new, highly parallel digital state machine generates a digital trigger signal at the onset of a video event. High capacity random access memory storage coupled with newly available fuzzy logic devices permits the monitoring of a video image stream for long term or short term changes caused by spatial translation, dilation, appearance, disappearance, or color change in a video object. Pretrigger and post-trigger storage techniques are then adaptable for archiving the digital stream from only the significant video images.

  12. Allometric equations for maximum filtration rate in blue mussels Mytilus edulis and importance of condition index

    DEFF Research Database (Denmark)

    Riisgård, Hans Ulrik; Larsen, Poul Scheel; Pleissner, Daniel

    2014-01-01

    rate (F, l h-1), W (g), and L (mm) as described by the equations: FW = aWb and FL = cLd, respectively. This is done by using available and new experimental laboratory data on M. edulis obtained by members of the same research team using different methods and controlled diets of cultivated algal cells...

  13. 76 FR 53134 - Maximum Per Diem Rates for the Continental United States (CONUS)

    Science.gov (United States)

    2011-08-25

    ... in the per diem rate setting process enhances the Government's ability to obtain policy-compliant...-standard area (NSA): Alexandria/Leesville/Natchitoches, Louisiana (Allen, Jefferson Davis, Natchitoches... the standard CONUS designation in FY 2011. Of those locations, the following areas will once again...

  14. Maximum inflation of the type 1 error rate when sample size and allocation rate are adapted in a pre-planned interim look.

    Science.gov (United States)

    Graf, Alexandra C; Bauer, Peter

    2011-06-30

    We calculate the maximum type 1 error rate of the pre-planned conventional fixed sample size test for comparing the means of independent normal distributions (with common known variance) which can be yielded when sample size and allocation rate to the treatment arms can be modified in an interim analysis. Thereby it is assumed that the experimenter fully exploits knowledge of the unblinded interim estimates of the treatment effects in order to maximize the conditional type 1 error rate. The 'worst-case' strategies require knowledge of the unknown common treatment effect under the null hypothesis. Although this is a rather hypothetical scenario it may be approached in practice when using a standard control treatment for which precise estimates are available from historical data. The maximum inflation of the type 1 error rate is substantially larger than derived by Proschan and Hunsberger (Biometrics 1995; 51:1315-1324) for design modifications applying balanced samples before and after the interim analysis. Corresponding upper limits for the maximum type 1 error rate are calculated for a number of situations arising from practical considerations (e.g. restricting the maximum sample size, not allowing sample size to decrease, allowing only increase in the sample size in the experimental treatment). The application is discussed for a motivating example. Copyright © 2011 John Wiley & Sons, Ltd.

  15. Framing the frame

    OpenAIRE

    Todd McElroy; John J. Seta

    2007-01-01

    We examined how the goal of a decision task influences the perceived positive, negative valence of the alternatives and thereby the likelihood and direction of framing effects. In Study 1 we manipulated the goal to increase, decrease or maintain the commodity in question and found that when the goal of the task was to increase the commodity, a framing effect consistent with those typically observed in the literature was found. When the goal was to decrease, a framing effect opposite to the ty...

  16. Imaging of vaporised sub-micron phase change contrast agents with high frame rate ultrasound and optics

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Jamburidze, Akaki; Chee, Melisse; Hau Leow, Chee; Garbin, Valeria; Tang, Meng-Xing

    2018-03-01

    Phase-change ultrasound contrast agent (PCCA), or nanodroplet, shows promise as an alternative to the conventional microbubble agent over a wide range of diagnostic applications. Meanwhile, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedented temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer the opportunity to observe and better understand PCCA behaviour after vaporisation captures the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5-20 kHz) to image native and size-selected PCCA populations immediately after vaporisation in vitro within clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve a sub-micron-sized (mean diameter  1 µm) that originate from native PCCA emulsion. The results demonstrate imaging signals with different amplitudes and temporal features compared to that of microbubbles. Compared with the microbubbles, both the B-mode and pulse-inversion (PI) signals from the vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only the B-mode signals from the PCCAs were recovered during the next 400 ms, suggesting significant changes to the size distribution of the PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed a change in particle size in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can further the understanding of PCCA behaviour under HFR ultrasound imaging.

  17. High-frame-rate imaging of biological samples with optoacoustic micro-tomography

    Science.gov (United States)

    Deán-Ben, X. Luís.; López-Schier, Hernán.; Razansky, Daniel

    2018-02-01

    Optical microscopy remains a major workhorse in biological discovery despite the fact that light scattering limits its applicability to depths of ˜ 1 mm in scattering tissues. Optoacoustic imaging has been shown to overcome this barrier by resolving optical absorption with microscopic resolution in significantly deeper regions. Yet, the time domain is paramount for the observation of biological dynamics in living systems that exhibit fast motion. Commonly, acquisition of microscopy data involves raster scanning across the imaged volume, which significantly limits temporal resolution in 3D. To overcome these limitations, we have devised a fast optoacoustic micro-tomography (OMT) approach based on simultaneous acquisition of 3D image data with a high-density hemispherical ultrasound array having effective detection bandwidth around 25 MHz. We performed experiments by imaging tissue-mimicking phantoms and zebrafish larvae, demonstrating that OMT can provide nearly cellular resolution and imaging speed of 100 volumetric frames per second. As opposed to other optical microscopy techniques, OMT is a hybrid method that resolves optical absorption contrast acoustically using unfocused light excitation. Thus, no penetration barriers are imposed by light scattering in deep tissues, suggesting it as a powerful approach for multi-scale functional and molecular imaging applications.

  18. Maximum Likelihood based comparison of the specific growth rates for P. aeruginosa and four mutator strains

    DEFF Research Database (Denmark)

    Philipsen, Kirsten Riber; Christiansen, Lasse Engbo; Mandsberg, Lotte Frigaard

    2008-01-01

    with an exponentially decaying function of the time between observations is suggested. A model with a full covariance structure containing OD-dependent variance and an autocorrelation structure is compared to a model with variance only and with no variance or correlation implemented. It is shown that the model...... are used for parameter estimation. The data is log-transformed such that a linear model can be applied. The transformation changes the variance structure, and hence an OD-dependent variance is implemented in the model. The autocorrelation in the data is demonstrated, and a correlation model...... that best describes data is a model taking into account the full covariance structure. An inference study is made in order to determine whether the growth rate of the five bacteria strains is the same. After applying a likelihood-ratio test to models with a full covariance structure, it is concluded...

  19. A rotation-symmetric, position-sensitive annular detector for maximum counting rates

    International Nuclear Information System (INIS)

    Igel, S.

    1993-12-01

    The Germanium Wall is a semiconductor detector system containing up to four annular position sensitive ΔE-detectors from high purity germanium (HPGe) planned to complement the BIG KARL spectrometer in COSY experiments. The first diode of the system, the Quirl-detector, has a two dimensional position sensitive structure defined by 200 Archimedes' spirals on each side with opposite orientation. In this way about 40000 pixels are defined. Since each spiral element detects almost the same number of events in an experiment the whole system can be optimized for maximal counting rates. This paper describes a test setup for a first prototype of the Quirl-detector and the results of test measurements with an α-source. The detector current and the electrical separation of the spiral elements were measured. The splitting of signals due to the spread of charge carriers produced by an incident ionizing particle on several adjacent elements was investigated in detail and found to be twice as high as expected from calculations. Its influence on energy and position resolution is discussed. Electronic crosstalk via signal wires and the influence of noise from the magnetic spectrometer has been tested under experimental conditions. Additionally, vacuum feedthroughs based on printed Kapton foils pressed between Viton seals were fabricated and tested successfully concerning their vacuum and thermal properties. (orig.)

  20. Late development of homoeothermy in mink (Mustela vison) kits - a strategy for maximum survival rate

    DEFF Research Database (Denmark)

    Tauson, A-H; Chwalibog, André; Tygesen, M P

    2006-01-01

    and after the experiments and evaporative water losses (EWL) were calculated. When exposed to L temperature, single kits responded with a very low HE until 29 days of age, and groups of kits until 14 days of age. It was not until they reached an age of approximately 6 weeks that single kits showed a clear...... thermoregulatory response to the L temperature by increased HE, whereas groups of kits showed increased HE from 29th day onwards. When kept at H temperature, HE was low initially, but all kits showed elevated HE at 8 days of age, and the metabolic rate was similar for single kits and kits huddling in groups....... Evaporative water losses was higher among single than among groups of kits and slightly lower but more variable for animals at L than at H temperature. It was concluded that mink kits develop functional homoeothermy at an age of close to 6 weeks and that the failure of very young kits to thermoregulate...

  1. Is there a maximum star formation rate in high-redshift galaxies? , , ,

    International Nuclear Information System (INIS)

    Barger, A. J.; Cowie, L. L.; Chen, C.-C.; Casey, C. M.; Lee, N.; Sanders, D. B.; Williams, J. P.; Owen, F. N.; Wang, W.-H.

    2014-01-01

    We use the James Clerk Maxwell Telescope's SCUBA-2 camera to image a 400 arcmin 2 area surrounding the GOODS-N field. The 850 μm rms noise ranges from a value of 0.49 mJy in the central region to 3.5 mJy at the outside edge. From these data, we construct an 850 μm source catalog to 2 mJy containing 49 sources detected above the 4σ level. We use an ultradeep (11.5 μJy at 5σ) 1.4 GHz image obtained with the Karl G. Jansky Very Large Array together with observations made with the Submillimeter Array to identify counterparts to the submillimeter galaxies. For most cases of multiple radio counterparts, we can identify the correct counterpart from new and existing Submillimeter Array data. We have spectroscopic redshifts for 62% of the radio sources in the 9' radius highest sensitivity region (556/894) and 67% of the radio sources in the GOODS-N region (367/543). We supplement these with a modest number of additional photometric redshifts in the GOODS-N region (30). We measure millimetric redshifts from the radio to submillimeter flux ratios for the unidentified submillimeter sample, assuming an Arp 220 spectral energy distribution. We find a radio-flux-dependent K – z relation for the radio sources, which we use to estimate redshifts for the remaining radio sources. We determine the star formation rates (SFRs) of the submillimeter sources based on their radio powers and their submillimeter fluxes and find that they agree well. The radio data are deep enough to detect star-forming galaxies with SFRs >2000 M ☉ yr –1 to z ∼ 6. We find galaxies with SFRs up to ∼6000 M ☉ yr –1 over the redshift range z = 1.5-6, but we see evidence for a turn-down in the SFR distribution function above 2000 M ☉ yr –1 .

  2. Is There a Maximum Star Formation Rate in High-redshift Galaxies?

    Science.gov (United States)

    Barger, A. J.; Cowie, L. L.; Chen, C.-C.; Owen, F. N.; Wang, W.-H.; Casey, C. M.; Lee, N.; Sanders, D. B.; Williams, J. P.

    2014-03-01

    We use the James Clerk Maxwell Telescope's SCUBA-2 camera to image a 400 arcmin2 area surrounding the GOODS-N field. The 850 μm rms noise ranges from a value of 0.49 mJy in the central region to 3.5 mJy at the outside edge. From these data, we construct an 850 μm source catalog to 2 mJy containing 49 sources detected above the 4σ level. We use an ultradeep (11.5 μJy at 5σ) 1.4 GHz image obtained with the Karl G. Jansky Very Large Array together with observations made with the Submillimeter Array to identify counterparts to the submillimeter galaxies. For most cases of multiple radio counterparts, we can identify the correct counterpart from new and existing Submillimeter Array data. We have spectroscopic redshifts for 62% of the radio sources in the 9' radius highest sensitivity region (556/894) and 67% of the radio sources in the GOODS-N region (367/543). We supplement these with a modest number of additional photometric redshifts in the GOODS-N region (30). We measure millimetric redshifts from the radio to submillimeter flux ratios for the unidentified submillimeter sample, assuming an Arp 220 spectral energy distribution. We find a radio-flux-dependent K - z relation for the radio sources, which we use to estimate redshifts for the remaining radio sources. We determine the star formation rates (SFRs) of the submillimeter sources based on their radio powers and their submillimeter fluxes and find that they agree well. The radio data are deep enough to detect star-forming galaxies with SFRs >2000 M ⊙ yr-1 to z ~ 6. We find galaxies with SFRs up to ~6000 M ⊙ yr-1 over the redshift range z = 1.5-6, but we see evidence for a turn-down in the SFR distribution function above 2000 M ⊙ yr-1. The James Clerk Maxwell Telescope is operated by the Joint Astronomy Centre on behalf of the Science and Technology Facilities Council of the United Kingdom, the National Research Council of Canada, and (until 2013 March 31) the Netherlands Organisation for Scientific

  3. ReplacementMatrix: a web server for maximum-likelihood estimation of amino acid replacement rate matrices.

    Science.gov (United States)

    Dang, Cuong Cao; Lefort, Vincent; Le, Vinh Sy; Le, Quang Si; Gascuel, Olivier

    2011-10-01

    Amino acid replacement rate matrices are an essential basis of protein studies (e.g. in phylogenetics and alignment). A number of general purpose matrices have been proposed (e.g. JTT, WAG, LG) since the seminal work of Margaret Dayhoff and co-workers. However, it has been shown that matrices specific to certain protein groups (e.g. mitochondrial) or life domains (e.g. viruses) differ significantly from general average matrices, and thus perform better when applied to the data to which they are dedicated. This Web server implements the maximum-likelihood estimation procedure that was used to estimate LG, and provides a number of tools and facilities. Users upload a set of multiple protein alignments from their domain of interest and receive the resulting matrix by email, along with statistics and comparisons with other matrices. A non-parametric bootstrap is performed optionally to assess the variability of replacement rate estimates. Maximum-likelihood trees, inferred using the estimated rate matrix, are also computed optionally for each input alignment. Finely tuned procedures and up-to-date ML software (PhyML 3.0, XRATE) are combined to perform all these heavy calculations on our clusters. http://www.atgc-montpellier.fr/ReplacementMatrix/ olivier.gascuel@lirmm.fr Supplementary data are available at http://www.atgc-montpellier.fr/ReplacementMatrix/

  4. High-frame rate imaging of two-phase flow in a thin rectangular channel using fast neutrons.

    Science.gov (United States)

    Zboray, R; Mor, I; Dangendorf, V; Stark, M; Tittelmeier, K; Cortesi, M; Adams, R

    2014-08-01

    We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 ms exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and mean bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Performance improvement of two-dimensional EUV spectroscopy based on high frame rate CCD and signal normalization method

    International Nuclear Information System (INIS)

    Zhang, H.M.; Morita, S.; Ohishi, T.; Goto, M.; Huang, X.L.

    2014-01-01

    In the Large Helical Device (LHD), the performance of two-dimensional (2-D) extreme ultraviolet (EUV) spectroscopy with wavelength range of 30-650A has been improved by installing a high frame rate CCD and applying a signal intensity normalization method. With upgraded 2-D space-resolved EUV spectrometer, measurement of 2-D impurity emission profiles with high horizontal resolution is possible in high-density NBI discharges. The variation in intensities of EUV emission among a few discharges is significantly reduced by normalizing the signal to the spectral intensity from EUV_—Long spectrometer which works as an impurity monitor with high-time resolution. As a result, high resolution 2-D intensity distribution has been obtained from CIV (384.176A), CV(2x40.27A), CVI(2x33.73A) and HeII(303.78A). (author)

  6. Framing the frame

    Directory of Open Access Journals (Sweden)

    Todd McElroy

    2007-08-01

    Full Text Available We examined how the goal of a decision task influences the perceived positive, negative valence of the alternatives and thereby the likelihood and direction of framing effects. In Study 1 we manipulated the goal to increase, decrease or maintain the commodity in question and found that when the goal of the task was to increase the commodity, a framing effect consistent with those typically observed in the literature was found. When the goal was to decrease, a framing effect opposite to the typical findings was observed whereas when the goal was to maintain, no framing effect was found. When we examined the decisions of the entire population, we did not observe a framing effect. In Study 2, we provided participants with a similar decision task except in this situation the goal was ambiguous, allowing us to observe participants' self-imposed goals and how they influenced choice preferences. The findings from Study 2 demonstrated individual variability in imposed goal and provided a conceptual replication of Study 1. %need keywords

  7. Maximum permissible continuous release rates of phosphorus-32 and sulphur-35 to atmosphere in a milk producing area

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, P M

    1963-01-01

    A method is given for calculating, for design purposes, the maximum permissible continuous release rates of phosphorus-32 and sulphur-35 to atmosphere with respect to milk contamination. In the absence of authoritative advice from the Medical Research Council, provisional working levels for the concentration of phosphorus-32 and sulphur-35 in milk are derived, and details are given of the agricultural assumptions involved in the calculation of the relationship between the amount of the nuclide deposited on grassland and that to be found in milk. The agricultural and meteorological conditions assumed are applicable as an annual average to England and Wales. The results (in mc/day) for phosphorus-32 and sulphur-35 for a number of stack heights and distances are shown graphically; typical values, quoted in a table, include 20 mc/day of phosphorus-32 and 30 mc/day of sulfur-35 as the maximum permissible continuous release rates with respect to ground level releases at a distance of 200 metres from pastureland.

  8. Maximum type I error rate inflation from sample size reassessment when investigators are blind to treatment labels.

    Science.gov (United States)

    Żebrowska, Magdalena; Posch, Martin; Magirr, Dominic

    2016-05-30

    Consider a parallel group trial for the comparison of an experimental treatment to a control, where the second-stage sample size may depend on the blinded primary endpoint data as well as on additional blinded data from a secondary endpoint. For the setting of normally distributed endpoints, we demonstrate that this may lead to an inflation of the type I error rate if the null hypothesis holds for the primary but not the secondary endpoint. We derive upper bounds for the inflation of the type I error rate, both for trials that employ random allocation and for those that use block randomization. We illustrate the worst-case sample size reassessment rule in a case study. For both randomization strategies, the maximum type I error rate increases with the effect size in the secondary endpoint and the correlation between endpoints. The maximum inflation increases with smaller block sizes if information on the block size is used in the reassessment rule. Based on our findings, we do not question the well-established use of blinded sample size reassessment methods with nuisance parameter estimates computed from the blinded interim data of the primary endpoint. However, we demonstrate that the type I error rate control of these methods relies on the application of specific, binding, pre-planned and fully algorithmic sample size reassessment rules and does not extend to general or unplanned sample size adjustments based on blinded data. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  9. Releasable activity and maximum permissible leakage rate within a transport cask of Tehran Research Reactor fuel samples

    Directory of Open Access Journals (Sweden)

    Rezaeian Mahdi

    2015-01-01

    Full Text Available Containment of a transport cask during both normal and accident conditions is important to the health and safety of the public and of the operators. Based on IAEA regulations, releasable activity and maximum permissible volumetric leakage rate within the cask containing fuel samples of Tehran Research Reactor enclosed in an irradiated capsule are calculated. The contributions to the total activity from the four sources of gas, volatile, fines, and corrosion products are treated separately. These calculations are necessary to identify an appropriate leak test that must be performed on the cask and the results can be utilized as the source term for dose evaluation in the safety assessment of the cask.

  10. Effects of adipose tissue distribution on maximum lipid oxidation rate during exercise in normal-weight women.

    Science.gov (United States)

    Isacco, L; Thivel, D; Duclos, M; Aucouturier, J; Boisseau, N

    2014-06-01

    Fat mass localization affects lipid metabolism differently at rest and during exercise in overweight and normal-weight subjects. The aim of this study was to investigate the impact of a low vs high ratio of abdominal to lower-body fat mass (index of adipose tissue distribution) on the exercise intensity (Lipox(max)) that elicits the maximum lipid oxidation rate in normal-weight women. Twenty-one normal-weight women (22.0 ± 0.6 years, 22.3 ± 0.1 kg.m(-2)) were separated into two groups of either a low or high abdominal to lower-body fat mass ratio [L-A/LB (n = 11) or H-A/LB (n = 10), respectively]. Lipox(max) and maximum lipid oxidation rate (MLOR) were determined during a submaximum incremental exercise test. Abdominal and lower-body fat mass were determined from DXA scans. The two groups did not differ in aerobic fitness, total fat mass, or total and localized fat-free mass. Lipox(max) and MLOR were significantly lower in H-A/LB vs L-A/LB women (43 ± 3% VO(2max) vs 54 ± 4% VO(2max), and 4.8 ± 0.6 mg min(-1)kg FFM(-1)vs 8.4 ± 0.9 mg min(-1)kg FFM(-1), respectively; P normal-weight women, a predominantly abdominal fat mass distribution compared with a predominantly peripheral fat mass distribution is associated with a lower capacity to maximize lipid oxidation during exercise, as evidenced by their lower Lipox(max) and MLOR. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    Energy Technology Data Exchange (ETDEWEB)

    Liang, A K; Koniczek, M; Antonuk, L E; El-Mohri, Y; Zhao, Q [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailed circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit

  12. Compliance Framing - Framing Compliance

    OpenAIRE

    Lutz-Ulrich Haack; Martin C. Reimann

    2012-01-01

    Corporations have to install various organizational measures to comply with legal as well as internal guidelines systematically. Compliance management systems have the challenging task to make use of an internal compliance-marketing approach in order to ensure not only an adequate but also effective compliance-culture. Compliance-literature and findings of persuasive goal-framing-theory give opposite implications for establishing a rather values- versus rule-based compliance-culture respectiv...

  13. Maximum standard metabolic rate corresponds with the salinity of maximum growth in hatchlings of the estuarine northern diamondback terrapin (Malaclemys terrapin terrapin): Implications for habitat conservation

    Science.gov (United States)

    Rowe, Christopher L.

    2018-01-01

    I evaluated standard metabolic rates (SMR) of hatchling northern diamondback terrapins (Malaclemys terrapin terrapin) across a range of salinities (salinity = 1.5, 4, 8, 12, and 16 psu) that they may encounter in brackish habitats such as those in the Maryland portion of the Chesapeake Bay, U.S.A. Consumption of O2 and production of CO2 by resting, unfed animals served as estimates of SMR. A peak in SMR occurred at 8 psu which corresponds closely with the salinity at which hatchling growth was previously shown to be maximized (salinity ∼ 9 psu). It appears that SMR is influenced by growth, perhaps reflecting investments in catabolic pathways that fuel anabolism. This ecophysiological information can inform environmental conservation and management activities by identifying portions of the estuary that are bioenergetically optimal for growth of hatchling terrapins. I suggest that conservation and restoration efforts to protect terrapin populations in oligo-to mesohaline habitats should prioritize protection or creation of habitats in regions where average salinity is near 8 psu and energetic investments in growth appear to be maximized.

  14. To the elementary theory of critical (maximum) flow rate of two-phase mixture in channels with various sections

    International Nuclear Information System (INIS)

    Nigmatulin, B.I.; Soplenkov, K.I.

    1978-01-01

    On the basis of the concepts of two-phase dispersive flow with various structures (bubble, vapour-drop etc) in the framework of the two-speed and two-temperature one-dimension stationary model of the current with provision for phase transitions the conditions, under which a critical (maximum) flow rate of two-phase mixture is achieved during its outflowing from a channel with the pre-set geometry, have been determined. It is shown, that for the choosen set of two-phase flow equations with the known parameters of deceleration and structure one of the critical conditions is satisfied: either solution of the set of equations corresponding a critical flow rate is a special one, i.e. passes through a special point locating between minimum and outlet channel sections where the carrying phase velocity approaches the value of decelerated sound speed in the mixture or the determinator of the initial set of equations equals zero for the outlet channel sections, i.e. gradients of the main flow parameters tend to +-infinity in this section, and carrying phase velocity also approaches the value of the decelerated sound velocity in the mixture

  15. Estimation of the players maximum heart rate in real game situations in team sports: a practical propose

    Directory of Open Access Journals (Sweden)

    Jorge Cuadrado Reyes

    2011-05-01

    Full Text Available Abstract   This  research developed a logarithms  for calculating the maximum heart rate (max. HR for players in team sports in  game situations. The sample was made of  thirteen players (aged 24 ± 3   to a  Division Two Handball team. HR was initially measured by Course Navette test.  Later, twenty one training sessions were conducted  in which HR and Rate of Perceived Exertion (RPE, were  continuously monitored, in each task. A lineal regression analysis was done  to help find a max. HR prediction equation from the max. HR of the three highest intensity sessions. Results from  this equation correlate significantly with data obtained in the Course Navette test and with those obtained by other indirect methods. The conclusion of this research is that this equation provides a very useful and easy way to measure the max. HR in real game situations, avoiding non-specific analytical tests and, therefore laboratory testing..   Key words: workout control, functional evaluation, prediction equation.

  16. Void fraction and velocity measurement of simulated bubble in a rotating disc using high frame rate neutron radiography.

    Science.gov (United States)

    Saito, Y; Mishima, K; Matsubayashi, M

    2004-10-01

    To evaluate measurement error of local void fraction and velocity field in a gas-molten metal two-phase flow by high-frame-rate neutron radiography, experiments using a rotating stainless-steel disc, which has several holes of various diameters and depths simulating gas bubbles, were performed. Measured instantaneous void fraction and velocity field of the simulated bubbles were compared with the calculated values based on the rotating speed, the diameter and the depth of the holes as parameters and the measurement error was evaluated. The rotating speed was varied from 0 to 350 rpm (tangential velocity of the simulated bubbles from 0 to 1.5 m/s). The effect of shutter speed of the imaging system on the measurement error was also investigated. It was revealed from the Lagrangian time-averaged void fraction profile that the measurement error of the instantaneous void fraction depends mainly on the light-decay characteristics of the fluorescent converter. The measurement error of the instantaneous local void fraction of simulated bubbles is estimated to be 20%. In the present imaging system, the light-decay characteristics of the fluorescent converter affect the measurement remarkably, and so should be taken into account in estimating the measurement error of the local void fraction profile.

  17. Measuring body layer vibration of vocal folds by high-frame-rate ultrasound synchronized with a modified electroglottograph.

    Science.gov (United States)

    Tang, Shanshan; Zhang, Yuanyuan; Qin, Xulei; Wang, Supin; Wan, Mingxi

    2013-07-01

    The body-cover concept suggests that the vibration of body layer is an indispensable component of vocal fold vibration. To quantify this vibration, a synchronized system composed of a high-frame-rate ultrasound and a modified electroglottograph (EGG) was employed in this paper to simultaneously image the body layer vibration and record the vocal fold vibration phase information during natural phonations. After data acquisition, the displacements of in vivo body layer vibrations were measured from the ultrasonic radio frequency data, and the temporal reconstruction method was used to enhance the measurement accuracy. Results showed that the modified EGG, the waveform and characteristic points of which were identical to the conventional EGG, resolved the position conflict between the ultrasound transducer and EGG electrodes. The location and range of the vibrating body layer in the estimated displacement image were more clear and discernible than in the ultrasonic B-mode image. Quantitative analysis for vibration features of the body layer demonstrated that the body layer moved as a unit in the superior-inferior direction during the phonation of normal chest registers.

  18. HEPS-BPIX, a single photon counting pixel detector with a high frame rate for the HEPS project

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Wei, E-mail: weiw@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Zhang, Jie; Ning, Zhe; Lu, Yunpeng; Fan, Lei; Li, Huaishen; Jiang, Xiaoshan; Lan, Allan K.; Ouyang, Qun; Wang, Zheng; Zhu, Kejun; Chen, Yuanbo [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Liu, Peng [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2016-11-01

    China's next generation light source, named the High Energy Photon Source (HEPS), is currently under construction. HEPS-BPIX (HEPS-Beijing PIXel) is a dedicated pixel readout chip that operates in single photon counting mode for X-ray applications in HEPS. Designed using CMOS 0.13 µm technology, the chip contains a matrix of 104×72 pixels. Each pixel measures 150 µm×150 µm and has a counting depth of 20 bits. A bump-bonded prototyping detector module with a 300-µm thick silicon sensor was tested in the beamline of Beijing Synchrotron Radiation Facility. A fast stream of X-ray images was demonstrated, and a frame rate of 1.2 kHz was proven, with a negligible dead time. The test results showed an equivalent noise charge of 115 e{sup −} rms after bump bonding and a threshold dispersion of 55 e{sup −} rms after calibration.

  19. Void fraction and velocity measurement of simulated bubble in a rotating disc using high frame rate neutron radiography

    International Nuclear Information System (INIS)

    Saito, Y.; Mishima, K.; Matsubayashi, M.

    2004-01-01

    To evaluate measurement error of local void fraction and velocity field in a gas-molten metal two-phase flow by high-frame-rate neutron radiography, experiments using a rotating stainless-steel disc, which has several holes of various diameters and depths simulating gas bubbles, were performed. Measured instantaneous void fraction and velocity field of the simulated bubbles were compared with the calculated values based on the rotating speed, the diameter and the depth of the holes as parameters and the measurement error was evaluated. The rotating speed was varied from 0 to 350 rpm (tangential velocity of the simulated bubbles from 0 to 1.5 m/s). The effect of shutter speed of the imaging system on the measurement error was also investigated. It was revealed from the Lagrangian time-averaged void fraction profile that the measurement error of the instantaneous void fraction depends mainly on the light-decay characteristics of the fluorescent converter. The measurement error of the instantaneous local void fraction of simulated bubbles is estimated to be 20%. In the present imaging system, the light-decay characteristics of the fluorescent converter affect the measurement remarkably, and so should be taken into account in estimating the measurement error of the local void fraction profile

  20. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    Science.gov (United States)

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  1. Biased representation of disturbance rates in the roadside sampling frame in boreal forests: implications for monitoring design

    Directory of Open Access Journals (Sweden)

    Steven L. Van Wilgenburg

    2015-12-01

    Full Text Available The North American Breeding Bird Survey (BBS is the principal source of data to inform researchers about the status of and trend for boreal forest birds. Unfortunately, little BBS coverage is available in the boreal forest, where increasing concern over the status of species breeding there has increased interest in northward expansion of the BBS. However, high disturbance rates in the boreal forest may complicate roadside monitoring. If the roadside sampling frame does not capture variation in disturbance rates because of either road placement or the use of roads for resource extraction, biased trend estimates might result. In this study, we examined roadside bias in the proportional representation of habitat disturbance via spatial data on forest "loss," forest fires, and anthropogenic disturbance. In each of 455 BBS routes, the area disturbed within multiple buffers away from the road was calculated and compared against the area disturbed in degree blocks and BBS strata. We found a nonlinear relationship between bias and distance from the road, suggesting forest loss and forest fires were underrepresented below 75 and 100 m, respectively. In contrast, anthropogenic disturbance was overrepresented at distances below 500 m and underrepresented thereafter. After accounting for distance from road, BBS routes were reasonably representative of the degree blocks they were within, with only a few strata showing biased representation. In general, anthropogenic disturbance is overrepresented in southern strata, and forest fires are underrepresented in almost all strata. Similar biases exist when comparing the entire road network and the subset sampled by BBS routes against the amount of disturbance within BBS strata; however, the magnitude of biases differed. Based on our results, we recommend that spatial stratification and rotating panel designs be used to spread limited BBS and off-road sampling effort in an unbiased fashion and that new BBS routes

  2. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, L., E-mail: liang.zhang@iphc.cnrs.fr [School of Physics, Key Laboratory of Particle Physics and Particle Irradiation, Shandong University, 250100 Jinan (China); Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France); Morel, F.; Hu-Guo, C.; Hu, Y. [Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France)

    2014-07-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm{sup 2}. The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors.

  3. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    International Nuclear Information System (INIS)

    Zhang, L.; Morel, F.; Hu-Guo, C.; Hu, Y.

    2014-01-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm 2 . The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors

  4. Efficient Photometry In-Frame Calibration (EPIC) Gaussian Corrections for Automated Background Normalization of Rate-Tracked Satellite Imagery

    Science.gov (United States)

    Griesbach, J.; Wetterer, C.; Sydney, P.; Gerber, J.

    Photometric processing of non-resolved Electro-Optical (EO) images has commonly required the use of dark and flat calibration frames that are obtained to correct for charge coupled device (CCD) dark (thermal) noise and CCD quantum efficiency/optical path vignetting effects respectively. It is necessary to account/calibrate for these effects so that the brightness of objects of interest (e.g. stars or resident space objects (RSOs)) may be measured in a consistent manner across the CCD field of view. Detected objects typically require further calibration using aperture photometry to compensate for sky background (shot noise). For this, annuluses are measured around each detected object whose contained pixels are used to estimate an average background level that is subtracted from the detected pixel measurements. In a new photometric calibration software tool developed for AFRL/RD, called Efficient Photometry In-Frame Calibration (EPIC), an automated background normalization technique is proposed that eliminates the requirement to capture dark and flat calibration images. The proposed technique simultaneously corrects for dark noise, shot noise, and CCD quantum efficiency/optical path vignetting effects. With this, a constant detection threshold may be applied for constant false alarm rate (CFAR) object detection without the need for aperture photometry corrections. The detected pixels may be simply summed (without further correction) for an accurate instrumental magnitude estimate. The noise distribution associated with each pixel is assumed to be sampled from a Poisson distribution. Since Poisson distributed data closely resembles Gaussian data for parameterized means greater than 10, the data may be corrected by applying bias subtraction and standard-deviation division. EPIC performs automated background normalization on rate-tracked satellite images using the following technique. A deck of approximately 50-100 images is combined by performing an independent median

  5. Frames and semi-frames

    International Nuclear Information System (INIS)

    Antoine, Jean-Pierre; Balazs, Peter

    2011-01-01

    Loosely speaking, a semi-frame is a generalized frame for which one of the frame bounds is absent. More precisely, given a total sequence in a Hilbert space, we speak of an upper (resp. lower) semi-frame if only the upper (resp. lower) frame bound is valid. Equivalently, for an upper semi-frame, the frame operator is bounded, but has an unbounded inverse, whereas a lower semi-frame has an unbounded frame operator, with a bounded inverse. We study mostly upper semi-frames, both in the continuous and discrete case, and give some remarks for the dual situation. In particular, we show that reconstruction is still possible in certain cases.

  6. Relationship between visual prostate score (VPSS and maximum flow rate (Qmax in men with urinary tract symptoms

    Directory of Open Access Journals (Sweden)

    Mazhar A. Memon

    2016-04-01

    Full Text Available ABSTRACT Objective: To evaluate correlation between visual prostate score (VPSS and maximum flow rate (Qmax in men with lower urinary tract symptoms. Material and Methods: This is a cross sectional study conducted at a university Hospital. Sixty-seven adult male patients>50 years of age were enrolled in the study after signing an informed consent. Qmax and voided volume recorded at uroflowmetry graph and at the same time VPSS were assessed. The education level was assessed in various defined groups. Pearson correlation coefficient was computed for VPSS and Qmax. Results: Mean age was 66.1±10.1 years (median 68. The mean voided volume on uroflowmetry was 268±160mL (median 208 and the mean Qmax was 9.6±4.96mLs/sec (median 9.0. The mean VPSS score was 11.4±2.72 (11.0. In the univariate linear regression analysis there was strong negative (Pearson's correlation between VPSS and Qmax (r=848, p<0.001. In the multiple linear regression analyses there was a significant correlation between VPSS and Qmax (β-http://www.blogapaixonadosporviagens.com.br/p/caribe.html after adjusting the effect of age, voided volume (V.V and level of education. Multiple linear regression analysis done for independent variables and results showed that there was no significant correlation between the VPSS and independent factors including age (p=0.27, LOE (p=0.941 and V.V (p=0.082. Conclusion: There is a significant negative correlation between VPSS and Qmax. The VPSS can be used in lieu of IPSS score. Men even with limited educational background can complete VPSS without assistance.

  7. Outpacing the Anthropocene: New Constraints for the Rate of Carbon Release at the Paleocene-Eocene Thermal Maximum

    Science.gov (United States)

    Wright, J. D.; Schaller, M. F.

    2012-12-01

    The Paleocene/Eocene Thermal Maximum (PETM) Carbon Isotope Excursion (CIE) is linked to benthic foraminiferal extinction and excursion taxa in planktonic foraminifera and calcareous nannofossils. Previous studies have used integrated bio-magneto-stratigraphies, cycle counting, and extraterrestrial 3He accumulation rates to produce a range of estimates for the duration of the initial onset of the PETM CIE between 750 years to 30 kyr. Durations for the total release time (onset to initiation of recovery) range from 45 to 95 kyr. Uncertainty in the timing of the onset of the PETM CIE prevents the identification of a causal mechanism, and hence understanding the biological responses. Recent work on the Paleocene/Eocene Marlboro Clay has unveiled the presence of regular couplets (~2 cm) expressed in multiple cores and exposures throughout the Atlantic Coastal Plain. Specifically, the Millville and newly recovered Wilson Lake B cores contain 750 and 660 layers through the CIE, respectively. These couplets have corresponding oxygen stable isotope cycles, arguing for a climatic origin. Orbital and millennial periodicities are far too long to explain the ~750 layers identified in the Millville core. Seasonal insolation is the only regular climate cycle that can plausibly account for the observed δ18O amplitudes (~1‰, with some cycles up to 2‰) and layer counts. Seasonal freshwater input can also augment the cyclic oscillations in δ18O, but the majority of the variability is most plausibly ascribed to temperature. Wilson Lake B and Millville have total δ13C excursions of -5 and -4.5‰ respectively, as well as highly expanded sections of the PETM CIE. In the Millville core, high-resolution, bulk stable isotope records show a 3.5‰ δ13C decrease over 12 layers across the PETM CIE onset. Concomitant with this δ13C decrease is a sharp drop in CaCO3. Decreases in both proxies require a large, sudden release of isotopically light carbon. The couplet chronology indicates

  8. Quantum frames

    Science.gov (United States)

    Brown, Matthew J.

    2014-02-01

    The framework of quantum frames can help unravel some of the interpretive difficulties i the foundation of quantum mechanics. In this paper, I begin by tracing the origins of this concept in Bohr's discussion of quantum theory and his theory of complementarity. Engaging with various interpreters and followers of Bohr, I argue that the correct account of quantum frames must be extended beyond literal space-time reference frames to frames defined by relations between a quantum system and the exosystem or external physical frame, of which measurement contexts are a particularly important example. This approach provides superior solutions to key EPR-type measurement and locality paradoxes.

  9. Media Framing

    DEFF Research Database (Denmark)

    Pedersen, Rasmus T.

    2017-01-01

    The concept of media framing refers to the way in which the news media organize and provide meaning to a news story by emphasizing some parts of reality and disregarding other parts. These patterns of emphasis and exclusion in news coverage create frames that can have considerable effects on news...... consumers’ perceptions and attitudes regarding the given issue or event. This entry briefly elaborates on the concept of media framing, presents key types of media frames, and introduces the research on media framing effects....

  10. Dragging of inertial frames inside the rotating neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Chandrachur; Modak, Kamakshya Prasad; Bandyopadhyay, Debades, E-mail: chandrachur.chakraborty@saha.ac.in, E-mail: kamakshya.modak@saha.ac.in [Astroparticle Physics and Cosmology Division, Saha Institute of Nuclear Physics, Kolkata 700064 (India)

    2014-07-20

    We derive the exact frame-dragging rate inside rotating neutron stars. This formula is applied to show that the frame-dragging rate monotonically decreases from the center to the surface of the neutron star along the pole. In the case of the frame-dragging rate along the equatorial distance, it decreases initially away from the center, becomes negligibly small well before the surface of the neutron star, rises again, and finally approaches to a small value at the surface. The appearance of a local maximum and minimum in this case is the result of the dependence of frame-dragging frequency on the distance and angle. Moving from the equator to the pole, it is observed that this local maximum and minimum in the frame-dragging rate along the equator disappear after crossing a critical angle. It is also noted that the positions of the local maximum and minimum of the frame-dragging rate along the equator depend on the rotation frequency and central energy density of a particular pulsar.

  11. Regional wall thickening in gated myocardial perfusion SPECT in a Japanese population: effect of sex, radiotracer, rotation angles and frame rates

    Energy Technology Data Exchange (ETDEWEB)

    Akhter, Nasima; Nakajima, Kenichi; Okuda, Koichi; Matsuo, Shinro; Yoneyama, Tatsuya; Taki, Junichi; Kinuya, Seigo [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa, Ishikawa (Japan)

    2008-09-15

    Gated single-photon emission computed tomography (SPECT) imaging of myocardium by {sup 99m}Tc and {sup 201}Tl is used extensively to measure quantitative cardiac functional parameters. However, factors affecting normal values for myocardial functional parameters and population-specific standards have not yet been established. The aim of the study was to determine the effect of sex, radiotracer, rotation angles and frame rates on resting myocardial wall thickening (WT) and to develop a Japanese standard of normal values for WT. Data from a total of 202 patients with low possibility of having cardiac problems were collected from nine hospitals throughout Japan. Patients were divided into five groups according to study protocol, and WT was evaluated according to the 17-segment and four-region (basal, mid and apical regions and the apex) polar map distribution. WT was generally higher in women than in men irrespective of the use of radiotracers, rotation angles or frame rates, and the difference was highly significant in the mid and apical regions. In any protocol used, resting myocardial thickening in the apex was higher than in the mid and apical regions, and thickening was lowest in the basal region, suggesting heterogeneous regional myocardial thickening (%) in normal subjects. Different rotation angles showed no significant change on WT, but different frame rates and tracers showed significant WT change in both sexes. Percent thickening of the myocardium was significantly higher in imaging by {sup 99m}Tc-labelled tracers than in {sup 201}Tl. Sex, radiotracers and frame rates had a significant effect on myocardial thickening, and the importance of population-specific standards should be emphasized. A normal database can serve as a standard for gated SPECT evaluation of myocardial thickening in a Japanese population and might be applicable to Asian populations having a similar physique. (orig.)

  12. Influence of phase separation on the anaerobic digestion of glucose: maximum COD turnover rate during continuous operation

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, A; Van Andel, J G; Breure, A M; Van Deursen, A

    1980-01-01

    A mineral medium containing 1% of glucose as the main carbon source was subjected to one-phase and two-phase anaerobic digestion processes under comparable conditions. The one-phase system combined acidogenic and methanogenic populations allowing a complete conversion of the carbon source into gaseous end products and biomass. The two-phase system consists of an acid reactor and a methane reactor connected in series allowing sequential acidogenesis and methanogenesis. Performance of the one-phase system is compared with that of the two-phase system. Maximum turnover of COD was determined for each system. Maximum specific sludge loading of the two-phase system was more than three times higher than that of the one-phase system. Effects of overloading each system were determined. The eco-physiological significance of phase separation is discussed briefly. (2 diagrams, 5 graphs, 41 references, 5 tables)

  13. A prospective interrupted time series study of interventions to improve the quality, rating, framing and structure of goal-setting in community-based brain injury rehabilitation.

    Science.gov (United States)

    Hassett, Leanne; Simpson, Grahame; Cotter, Rachel; Whiting, Diane; Hodgkinson, Adeline; Martin, Diane

    2015-04-01

    To investigate whether the introduction of an electronic goals system followed by staff training improved the quality, rating, framing and structure of goals written by a community-based brain injury rehabilitation team. Interrupted time series design. Two interventions were introduced six months apart. The first intervention comprised the introduction of an electronic goals system. The second intervention comprised a staff goal training workshop. An audit protocol was devised to evaluate the goals. A random selection of goal statements from the 12 months prior to the interventions (Time 1 baseline) were compared with all goal statements written after the introduction of the electronic goals system (Time 2) and staff training (Time 3). All goals were de-identified for client and time-period, and randomly ordered. A total of 745 goals (Time 1 n = 242; Time 2 n = 283; Time 3 n = 220) were evaluated. Compared with baseline, the introduction of the electronic goals system alone significantly increased goal rating, framing and structure (χ(2) tests 144.7, 18.9, 48.1, respectively, p goal quality, which was only a trend at Time 2, was statistically significant at Time 3 (χ(2) 15.0, p ≤ 001). The training also led to a further significant increase in the framing and structuring of goals over the electronic goals system (χ(2) 11.5, 12.5, respectively, p ≤ 0.001). An electronic goals system combined with staff training improved the quality, rating, framing and structure of goal statements. © The Author(s) 2014.

  14. The relationship between the parameters (Heart rate, Ejection fraction and BMI) and the maximum enhancement time of ascending aorta

    International Nuclear Information System (INIS)

    Jang, Young Ill; June, Woon Kwan; Dong, Kyeong Rae

    2007-01-01

    In this study, Bolus Tracking method was used to investigate the parameters affecting the time when contrast media is reached at 100 HU (T 100 ) and studied the relationship between parameters and T 100 because the time which is reached at aorta through antecubital vein after injecting contrast media is different from person to person. Using 64 MDCT, Cadiac CT, the data were obtained from 100 patients (male: 50, female: 50, age distribution: 21⁓81, average age: 57.5) during July and September, 2007 by injecting the contrast media at 4 ml∙sec -1 through their antecubital vein except having difficulties in stopping their breath and having arrhythmia. Using Somatom Sensation Cardiac 64 Siemens, patients’ height and weight were measured to know their mean Heart rate and BMI. Ejection Fraction was measured using Argus Program at Wizard Workstation. Variances of each parameter were analyzed depending on T 100 ’s variation with multiple comparison and the correlation of Heart rate, Ejection Fraction and BMI were analyzed, as well. According to T 100 ’s variation caused by Heart rate, Ejection Fraction and BMI variations, the higher patients’ Heart Rate and Ejection Fraction were, the faster T 100 ’s variations caused by Heart Rate and Ejection Fraction were. The lower their Heart Rate and Ejection Fraction were, the slower T 100 ’s variations were, but T 100 ’s variations caused by BMI were not affected. In the correlation between T 100 and parameters, Heart Rate (p⁄0.01) and Ejection Fraction (p⁄0.05) were significant, but BMI was not significant (p¤0.05). In the Heart Rate, Ejection Fraction and BMI depending on Fast (17 sec and less), Medium (18⁓21 sec), Slow (22 sec and over) Heart Rate was significant at Fast and Slow and Ejection Fraction was significant Fast and Slow as well as Medium and Slow (p⁄0.05), but BMI was not statistically significant. Of the parameters (Heart Rate, Ejection Fraction and BMI) which would affect T 100 , Heart

  15. Framing theory

    NARCIS (Netherlands)

    de Vreese, C.H.; Lecheler, S.; Mazzoleni, G.; Barnhurst, K.G.; Ikeda, K.; Maia, R.C.M.; Wessler, H.

    2016-01-01

    Political issues can be viewed from different perspectives and they can be defined differently in the news media by emphasizing some aspects and leaving others aside. This is at the core of news framing theory. Framing originates within sociology and psychology and has become one of the most used

  16. On Framing

    DEFF Research Database (Denmark)

    Peder Pedersen, Claus

    2018-01-01

    On framing as artistic and conceptual tool in the works of Claudia Carbone. Contribution to exhibition at the Aarhus School of Architecture.......On framing as artistic and conceptual tool in the works of Claudia Carbone. Contribution to exhibition at the Aarhus School of Architecture....

  17. Framing politics

    NARCIS (Netherlands)

    Lecheler, S.K.

    2010-01-01

    This dissertation supplies a number of research findings that add to a theory of news framing effects, and also to the understanding of the role media effects play in political communication. We show that researchers must think more about what actually constitutes a framing effect, and that a

  18. Investigation of the Maximum Spin-Up Coefficients of Friction Obtained During Tests of a Landing Gear Having a Static-Load Rating of 20,000 Pounds

    Science.gov (United States)

    Batterson, Sidney A.

    1959-01-01

    An experimental investigation was made at the Langley landing loads track to obtain data on the maximum spin-up coefficients of friction developed by a landing gear having a static-load rating of 20,000 pounds. The forward speeds ranged from 0 to approximately 180 feet per second and the sinking speeds, from 2.7 feet per second to 9.4 feet per second. The results indicated the variation of the maximum spin-up coefficient of friction with forward speed and vertical load. Data obtained during this investigation are also compared with some results previously obtained for nonrolling tires to show the effect of forward speed.

  19. 9 CFR 381.67 - Young chicken and squab slaughter inspection rate maximums under traditional inspection procedure.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Young chicken and squab slaughter... INSPECTION REGULATIONS Operating Procedures § 381.67 Young chicken and squab slaughter inspection rate... inspector per minute under the traditional inspection procedure for the different young chicken and squab...

  20. Five-Factor Personality Traits and Age Trajectories of Self-Rated Health: The Role of Question Framing

    Science.gov (United States)

    Löckenhoff, Corinna E.; Terracciano, Antonio; Ferrucci, Luigi; Costa, Paul T.

    2011-01-01

    We examined the influence of personality traits on mean levels and age trends in four single-item measures of self-rated health: General rating, comparison to age peers, comparison to past health, and expectations for future health. Community-dwelling participants (N = 1,683) completed 7,474 self-rated health assessments over a period of up to 19-years. In hierarchical linear modeling analyses, age-associated declines differed across the four health items. Across age groups, high neuroticism and low conscientiousness, low extraversion, and low openness were associated with worse health ratings, with notable differences across the four health items. Furthermore, high neuroticism predicted steeper declines in health ratings involving temporal comparisons. We consider theoretical implications regarding the mechanisms behind associations among personality traits and self-rated health. PMID:21299558

  1. THE EFFECT OF HYPOXIA ON THE MAXIMUM MATABOLIC RATE AND SPECIFIC DYNAMIC ACTION IN ATLANTIC COD Gadus morhua

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2010-01-01

    John Fleng Steffensen' and Anders Drud Jordan Aquaculture 2010 - San Diego - Physiological Insights Towards Improving Fish Culture. Hypoxia is an increasing problem in coastal near areas and estuaries. Hypoxia can also be a problem in aquaculture systems with a high degree of recirculating water...... reduced the Scope for Activity by 55 % in nonnoxia. In hypoxia the effect was more pronounced with a 69 % reduction of the scope for activity. In conclusion hypoxia prolong the postabsorptive state of fi sh by limiting the peak metabolic rate, causing that less food is assimilated over a certain period...

  2. Competitive Framing

    OpenAIRE

    Ran Spiegler

    2014-01-01

    I present a simple framework for modeling two-firm market competition when consumer choice is "frame-dependent", and firms use costless "marketing messages" to influence the consumer's frame. This framework embeds several recent models in the "behavioral industrial organization" literature. I identify a property that consumer choice may satisfy, which extends the concept of Weighted Regularity due to Piccione and Spiegler (2012), and provide a characterization of Nash equilibria under this pr...

  3. Implementation of a Low Frame-Rate Protocol and Noise-Reduction Technology to Minimize Radiation Dose in Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Maccagni, Davide; Candilio, Luciano; Latib, Azeem; Godino, Cosmo; Chieffo, Alaide; Montorfano, Matteo; Colombo, Antonio; Azzalini, Lorenzo

    2018-05-01

    Limiting radiation exposure is necessary in radiological procedures. This study evaluates the impact of a radiological low frame-rate protocol in a standard angiographic system and the implementation of a noise-reduction technology (NRT) on patient radiation exposure during transcatheter aortic valve replacement (TAVR). Transfemoral TAVR procedures performed between February 2016 and February 2017 were analyzed according to two angiographic systems, Standard and NRT, and further divided in four subgroups: (1) Standard 15 frames per second (fps) with 15 fps for both fluoroscopy and cine acquisitions; (2) Standard 7.5 fps with 7.5 fps for both fluoroscopy and cine acquisitions; (3) NRT 15 fps with 15 fps for both fluoroscopy and cine acquisitions; and (4) NRT 7.5 fps with 15 fps for fluoroscopy and 7.5 fps for cine acquisitions. Study endpoints were kerma area product (KAP) and cumulative air kerma at interventional reference point (AK at IRP). Significant differences were found in KAP (153 Gy·cm² [IQR, 95-234 Gy·cm²] vs 78.3 Gy·cm² [IQR, 54.4-103.5 Gy·cm²]; Pfps and Standard 7.5 fps groups (184 Gy·cm² [IQR, 128-262 Gy·cm²] vs 106.8 Gy·cm² [IQR, 76.87-181 Gy·cm²] [P<.01] and 0.973 Gy [IQR, 0.642-1.786 Gy] vs 0.64 Gy [IQR, 0.489-0.933 Gy] [P<.01], respectively). The present study suggests that the low frame-rate protocol in Standard system and NRT implementation allows a marked reduction of patient radiation exposure in TAVR procedures.

  4. Should measurement of maximum urinary flow rate and residual urine volume be a part of a "minimal care" assessment programme in female incontinence?

    DEFF Research Database (Denmark)

    Sander, Pia; Mouritsen, L; Andersen, J Thorup

    2002-01-01

    OBJECTIVE: The aim of this study was to evaluate the value of routine measurements of urinary flow rate and residual urine volume as a part of a "minimal care" assessment programme for women with urinary incontinence in detecting clinical significant bladder emptying problems. MATERIAL AND METHODS....... Twenty-six per cent had a maximum flow rate less than 15 ml/s, but only 4% at a voided volume > or =200 ml. Residual urine more than 149 ml was found in 6%. Two women had chronic retention with overflow incontinence. Both had typical symptoms with continuous leakage, stranguria and chronic cystitis...

  5. Formal comment on: Myhrvold (2016) Dinosaur metabolism and the allometry of maximum growth rate. PLoS ONE; 11(11): e0163205.

    Science.gov (United States)

    Griebeler, Eva Maria; Werner, Jan

    2018-01-01

    In his 2016 paper, Myhrvold criticized ours from 2014 on maximum growth rates (Gmax, maximum gain in body mass observed within a time unit throughout an individual's ontogeny) and thermoregulation strategies (ectothermy, endothermy) of 17 dinosaurs. In our paper, we showed that Gmax values of similar-sized extant ectothermic and endothermic vertebrates overlap. This strongly questions a correct assignment of a thermoregulation strategy to a dinosaur only based on its Gmax and (adult) body mass (M). Contrary, Gmax separated similar-sized extant reptiles and birds (Sauropsida) and Gmax values of our studied dinosaurs were similar to those seen in extant similar-sized (if necessary scaled-up) fast growing ectothermic reptiles. Myhrvold examined two hypotheses (H1 and H2) regarding our study. However, we did neither infer dinosaurian thermoregulation strategies from group-wide averages (H1) nor were our results based on that Gmax and metabolic rate (MR) are related (H2). In order to assess whether single dinosaurian Gmax values fit to those of extant endotherms (birds) or of ectotherms (reptiles), we already used a method suggested by Myhrvold to avoid H1, and we only discussed pros and cons of a relation between Gmax and MR and did not apply it (H2). We appreciate Myhrvold's efforts in eliminating the correlation between Gmax and M in order to statistically improve vertebrate scaling regressions on maximum gain in body mass. However, we show here that his mass-specific maximum growth rate (kC) replacing Gmax (= MkC) does not model the expected higher mass gain in larger than in smaller species for any set of species. We also comment on, why we considered extant reptiles and birds as reference models for extinct dinosaurs and why we used phylogenetically-informed regression analysis throughout our study. Finally, we question several arguments given in Myhrvold in order to support his results.

  6. Multi-rate Poisson tree processes for single-locus species delimitation under maximum likelihood and Markov chain Monte Carlo.

    Science.gov (United States)

    Kapli, P; Lutteropp, S; Zhang, J; Kobert, K; Pavlidis, P; Stamatakis, A; Flouri, T

    2017-06-01

    In recent years, molecular species delimitation has become a routine approach for quantifying and classifying biodiversity. Barcoding methods are of particular importance in large-scale surveys as they promote fast species discovery and biodiversity estimates. Among those, distance-based methods are the most common choice as they scale well with large datasets; however, they are sensitive to similarity threshold parameters and they ignore evolutionary relationships. The recently introduced "Poisson Tree Processes" (PTP) method is a phylogeny-aware approach that does not rely on such thresholds. Yet, two weaknesses of PTP impact its accuracy and practicality when applied to large datasets; it does not account for divergent intraspecific variation and is slow for a large number of sequences. We introduce the multi-rate PTP (mPTP), an improved method that alleviates the theoretical and technical shortcomings of PTP. It incorporates different levels of intraspecific genetic diversity deriving from differences in either the evolutionary history or sampling of each species. Results on empirical data suggest that mPTP is superior to PTP and popular distance-based methods as it, consistently yields more accurate delimitations with respect to the taxonomy (i.e., identifies more taxonomic species, infers species numbers closer to the taxonomy). Moreover, mPTP does not require any similarity threshold as input. The novel dynamic programming algorithm attains a speedup of at least five orders of magnitude compared to PTP, allowing it to delimit species in large (meta-) barcoding data. In addition, Markov Chain Monte Carlo sampling provides a comprehensive evaluation of the inferred delimitation in just a few seconds for millions of steps, independently of tree size. mPTP is implemented in C and is available for download at http://github.com/Pas-Kapli/mptp under the GNU Affero 3 license. A web-service is available at http://mptp.h-its.org . : paschalia.kapli@h-its.org or

  7. Seismic testing of a three-hour fire-rated steel-framed gypsum drywall partition for nuclear plants

    International Nuclear Information System (INIS)

    Thulin, F.A. Jr.

    1983-01-01

    The test specimen measured 1.22 by 3.05 m and consisted of three layers of 12.7 mm SHEETROCK Brand FIRECODE 'C' Gypsum Panels screw-attached to both sides of USG Steel 35SJ18 Studs 610 mm on centers. The specimen was first mounted in the earthquake simulator with the studs oriented horizontally and the runners vertically. Each runner was secured to a shaker support through which horizontal sinusoidal movement was induced normal to the surface of the wall. The damping ratio was found to be 9%. The average dynamic EI of the panel was 177000 GNxmm 2 . After the OBE scans, the specimen withstood the SSE scan for frequencies between 4 and 25 Hz. Resonance occured at 9 Hz. With a support acceleration of 3.0 gsub(e), the midspan acceleration reached 6.83 gsub(e). The same specimen was rotated 90 0 to a horizontal position with each runner attached to the corresponding shaker support which induced sinusoidal motion parallel to the runners. In the SSE shake at a frequency of 9 Hz and a support acceleration of 3.0 gsub(e), the midspan acceleration reached 4.66 gsub(e). To confirm the structural integrity of the specimen, it was then mounted in a vacuum chamber and tested in accordance with ASTM E 72. The rollers were spaced at 2.98 m. The panel yielded at a uniform load of 20.8 kN (equivalent to force at 8.8 gsub(e) acceleration) and failed at 26.3 kN (11.1 gsub(e)); both values greater than the 6.83 gsub(e) maximum dynamic midspan acceleration. The average static EI was 136000 GNxmm 2 - close to the 177000 GNxmm 2 dynamic EI. This transverse load test showed that the specimen was not structurally damaged by the shaker tests simulating earthquakes in nuclear plants. (orig./HP)

  8. A motion-tolerant approach for monitoring SpO2 and heart rate using photoplethysmography signal with dual frame length processing and multi-classifier fusion.

    Science.gov (United States)

    Fan, Feiyi; Yan, Yuepeng; Tang, Yongzhong; Zhang, Hao

    2017-12-01

    Monitoring pulse oxygen saturation (SpO 2 ) and heart rate (HR) using photoplethysmography (PPG) signal contaminated by a motion artifact (MA) remains a difficult problem, especially when the oximeter is not equipped with a 3-axis accelerometer for adaptive noise cancellation. In this paper, we report a pioneering investigation on the impact of altering the frame length of Molgedey and Schuster independent component analysis (ICAMS) on performance, design a multi-classifier fusion strategy for selecting the PPG correlated signal component, and propose a novel approach to extract SpO 2 and HR readings from PPG signal contaminated by strong MA interference. The algorithm comprises multiple stages, including dual frame length ICAMS, a multi-classifier-based PPG correlated component selector, line spectral analysis, tree-based HR monitoring, and post-processing. Our approach is evaluated by multi-subject tests. The root mean square error (RMSE) is calculated for each trial. Three statistical metrics are selected as performance evaluation criteria: mean RMSE, median RMSE and the standard deviation (SD) of RMSE. The experimental results demonstrate that a shorter ICAMS analysis window probably results in better performance in SpO 2 estimation. Notably, the designed multi-classifier signal component selector achieved satisfactory performance. The subject tests indicate that our algorithm outperforms other baseline methods regarding accuracy under most criteria. The proposed work can contribute to improving the performance of current pulse oximetry and personal wearable monitoring devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. An analysis of radiation dose reduction in paediatric interventional cardiology by altering frame rate and use of the anti-scatter grid

    International Nuclear Information System (INIS)

    McFadden, S L; Hughes, C M; Winder, Robert J; Mooney, R B

    2013-01-01

    The purpose of this work is to investigate removal of the anti-scatter grid and alteration of the frame rate in paediatric interventional cardiology (IC) and assess the impact on radiation dose and image quality. Phantom based experimental studies were performed in a dedicated cardiac catheterisation suite to investigate variations in radiation dose and image quality, with various changes in imaging parameters. Phantom based experimental studies employing these variations in technique identified that radiation dose reductions of 28%–49% can be made to the patient with minimal loss of image quality in smaller sized patients. At present, there is no standard technique for carrying out paediatric IC in the UK or Ireland, resulting in the potential for a wide variation in radiation dose. Dose reductions to patients can be achieved with slight alterations to the imaging equipment with minimal compromise to the image quality. These simple modifications can be easily implemented in clinical practice in IC centres. (paper)

  10. Framing scales and scaling frames

    NARCIS (Netherlands)

    van Lieshout, M.; Dewulf, A.; Aarts, N.; Termeer, K.

    2009-01-01

    Policy problems are not just out there. Actors highlight different aspects of a situation as problematic and situate the problem on different scales. In this study we will analyse the way actors apply scales in their talk (or texts) to frame the complex decision-making process of the establishment

  11. Framing Innovation

    DEFF Research Database (Denmark)

    Haase, Louise Møller; Laursen, Linda Nhu

    2017-01-01

    Designing a remarkable product innovation is a difficult challenge, which businesses today continuously are striving to tackle. This challenge is particularly present in the early phase of innovation, where the main product concept and frames of the innovation is determined. As a main challenge...... in the early phase is the reasoning process; innovation team are faced with open-ended ill-defines problems, where they need to make decisions about an unknown future having only incomplete, ambiguous and contradicting insights available. We study the reasoning of experts, how they frame to make sense of all...... the insights and create a basis for decision making in relation to a new project. Based on case studies of five innovative products from various industries, we suggest a Product Reasoning Model for understanding reasoning and envisioning of new product innovations in the early phases...

  12. Framing Innovation

    DEFF Research Database (Denmark)

    Haase, Louise Møller; Laursen, Linda Nhu

    2017-01-01

    Designing a remarkable product innovation is a difficult challenge, which businesses today continuously are striving to tackle. This challenge is particularly present in the early phase of innovation, where the main product concept and frames of the innovation is determined. As a main challenge...... in the early phase is the reasoning process; innovation team are faced with open- ended ill-defines problems, where they need to make decisions about an unknown future having only incomplete, ambiguous and contradicting insights available. We study the reasoning of experts, how they frame to make sense of all...... the insights and create a basis for decision making in relation to a new project. Based on case studies of five innovative products from various industries, we suggest a Product Reasoning Model for understanding reasoning and envisioning of new product innovations in the early phases of innovation....

  13. Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    Science.gov (United States)

    Wang, Yi; Zhang, Yaoyu; Zhao, Xuna; Wu, Bing; Gao, Jia-Hong

    2017-11-01

    To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. The difference in the longitudinal relaxation rate in the rotating frame ( ΔR1ρ) was calculated based on perturbation of the Z-value by R1ρ, and a saturation-pulse-amplitude-compensated exchange-dependent relaxation rate (SPACER) was determined with a high-exchange-rate approximation. In both phantom and human subject experiments, MTRasym (representative of the traditional CEST index), ΔR1ρ, and SPACER were measured, evaluated, and compared by altering the non-CE parameters in a transient-state continuous-wave CEST sequence. In line with the theoretical expectation, our experimental data demonstrate that the effects of the non-CE parameters can be more effectively reduced using the proposed indices (  ΔR1ρ and SPACER) than using the traditional CEST index ( MTRasym). The proposed method allows for the chemical exchange weight to be better emphasized in the transient-state CEST signal, which is beneficial, in practice, for quantifying the CEST signal. Magn Reson Med 78:1711-1723, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. A simulation study of Linsley's approach to infer elongation rate and fluctuations of the EAS maximum depth from muon arrival time distributions

    International Nuclear Information System (INIS)

    Badea, A.F.; Brancus, I.M.; Rebel, H.; Haungs, A.; Oehlschlaeger, J.; Zazyan, M.

    1999-01-01

    The average depth of the maximum X m of the EAS (Extensive Air Shower) development depends on the energy E 0 and the mass of the primary particle, and its dependence from the energy is traditionally expressed by the so-called elongation rate D e defined as change in the average depth of the maximum per decade of E 0 i.e. D e = dX m /dlog 10 E 0 . Invoking the superposition model approximation i.e. assuming that a heavy primary (A) has the same shower elongation rate like a proton, but scaled with energies E 0 /A, one can write X m = X init + D e log 10 (E 0 /A). In 1977 an indirect approach studying D e has been suggested by Linsley. This approach can be applied to shower parameters which do not depend explicitly on the energy of the primary particle, but do depend on the depth of observation X and on the depth X m of shower maximum. The distribution of the EAS muon arrival times, measured at a certain observation level relatively to the arrival time of the shower core reflect the pathlength distribution of the muon travel from locus of production (near the axis) to the observation locus. The basic a priori assumption is that we can associate the mean value or median T of the time distribution to the height of the EAS maximum X m , and that we can express T = f(X,X m ). In order to derive from the energy variation of the arrival time quantities information about elongation rate, some knowledge is required about F i.e. F = - ∂ T/∂X m ) X /∂(T/∂X) X m , in addition to the variations with the depth of observation and the zenith-angle (θ) dependence, respectively. Thus ∂T/∂log 10 E 0 | X = - F·D e ·1/X v ·∂T/∂secθ| E 0 . In a similar way the fluctuations σ(X m ) of X m may be related to the fluctuations σ(T) of T i.e. σ(T) = - σ(X m )· F σ ·1/X v ·∂T/∂secθ| E 0 , with F σ being the corresponding scaling factor for the fluctuation of F. By simulations of the EAS development using the Monte Carlo code CORSIKA the energy and angle

  15. Measuring maximum and standard metabolic rates using intermittent-flow respirometry: a student laboratory investigation of aerobic metabolic scope and environmental hypoxia in aquatic breathers.

    Science.gov (United States)

    Rosewarne, P J; Wilson, J M; Svendsen, J C

    2016-01-01

    Metabolic rate is one of the most widely measured physiological traits in animals and may be influenced by both endogenous (e.g. body mass) and exogenous factors (e.g. oxygen availability and temperature). Standard metabolic rate (SMR) and maximum metabolic rate (MMR) are two fundamental physiological variables providing the floor and ceiling in aerobic energy metabolism. The total amount of energy available between these two variables constitutes the aerobic metabolic scope (AMS). A laboratory exercise aimed at an undergraduate level physiology class, which details the appropriate data acquisition methods and calculations to measure oxygen consumption rates in rainbow trout Oncorhynchus mykiss, is presented here. Specifically, the teaching exercise employs intermittent flow respirometry to measure SMR and MMR, derives AMS from the measurements and demonstrates how AMS is affected by environmental oxygen. Students' results typically reveal a decline in AMS in response to environmental hypoxia. The same techniques can be applied to investigate the influence of other key factors on metabolic rate (e.g. temperature and body mass). Discussion of the results develops students' understanding of the mechanisms underlying these fundamental physiological traits and the influence of exogenous factors. More generally, the teaching exercise outlines essential laboratory concepts in addition to metabolic rate calculations, data acquisition and unit conversions that enhance competency in quantitative analysis and reasoning. Finally, the described procedures are generally applicable to other fish species or aquatic breathers such as crustaceans (e.g. crayfish) and provide an alternative to using higher (or more derived) animals to investigate questions related to metabolic physiology. © 2016 The Fisheries Society of the British Isles.

  16. SU-F-I-77: Radiation Dose in Cardiac Catheterization Procedures: Impact of a Systematic Reduction in Pulsed Fluoroscopy Frame Rate

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, C; Dixon, S [Beaumont Hospital, Royal Oak, MI (United States)

    2016-06-15

    Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kerma (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.

  17. FishFrame

    DEFF Research Database (Denmark)

    Degel, Henrik; Jansen, Teunis

    2006-01-01

    . Development and test of software modules can be done once and reused by all. The biggest challenge in this is not technical – it is in organisation, coordination and trust. This challenge has been addressed by FishFrame - a web-based datawarehouse application. The “bottom-up” approach with maximum involvement...... of end users from as many labs and user groups as possible has been rather slow but quite successful in building international trust and cooperation around the system. This is mandatory prerequisites when our primary goal is not the programming project itself, but the creation of a tool that adds real...... value to users and in the end improves the way we work with our data. FishFrame version 4.2 is presented and the lessons learned from the process are discussed....

  18. Framing (implicitly) matters

    DEFF Research Database (Denmark)

    Anderson, Joel; Antalikova, Radka

    2014-01-01

    Denmark is currently experiencing the highest immigration rate in its modern history. Population surveys indicate that negative public attitudes toward immigrants actually stem from attitudes toward their (perceived) Islamic affiliation. We used a framing paradigm to investigate the explicit...... and implicit attitudes of Christian and Atheist Danes toward targets framed as Muslims or as immigrants. The results showed that explicit and implicit attitudes were more negative when the target was framed as a Muslim, rather than as an immigrant. Interestingly, implicit attitudes were qualified...... by the participants’ religion. Specifically, analyses revealed that Christians demonstrated more negative implicit attitudes toward immigrants than Muslims. Conversely, Atheists demonstrated more negative implicit attitudes toward Muslims than Atheists. These results suggest a complex relationship between religion...

  19. n-Order and maximum fuzzy similarity entropy for discrimination of signals of different complexity: Application to fetal heart rate signals.

    Science.gov (United States)

    Zaylaa, Amira; Oudjemia, Souad; Charara, Jamal; Girault, Jean-Marc

    2015-09-01

    This paper presents two new concepts for discrimination of signals of different complexity. The first focused initially on solving the problem of setting entropy descriptors by varying the pattern size instead of the tolerance. This led to the search for the optimal pattern size that maximized the similarity entropy. The second paradigm was based on the n-order similarity entropy that encompasses the 1-order similarity entropy. To improve the statistical stability, n-order fuzzy similarity entropy was proposed. Fractional Brownian motion was simulated to validate the different methods proposed, and fetal heart rate signals were used to discriminate normal from abnormal fetuses. In all cases, it was found that it was possible to discriminate time series of different complexity such as fractional Brownian motion and fetal heart rate signals. The best levels of performance in terms of sensitivity (90%) and specificity (90%) were obtained with the n-order fuzzy similarity entropy. However, it was shown that the optimal pattern size and the maximum similarity measurement were related to intrinsic features of the time series. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Petroleum production at Maximum Efficient Rate Naval Petroleum Reserve No. 1 (Elk Hills), Kern County, California. Final Supplemental Environmental Impact Statement

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    This document provides an analysis of the potential impacts associated with the proposed action, which is continued operation of Naval Petroleum Reserve No. I (NPR-1) at the Maximum Efficient Rate (MER) as authorized by Public law 94-258, the Naval Petroleum Reserves Production Act of 1976 (Act). The document also provides a similar analysis of alternatives to the proposed action, which also involve continued operations, but under lower development scenarios and lower rates of production. NPR-1 is a large oil and gas field jointly owned and operated by the federal government and Chevron U.SA Inc. (CUSA) pursuant to a Unit Plan Contract that became effective in 1944; the government`s interest is approximately 78% and CUSA`s interest is approximately 22%. The government`s interest is under the jurisdiction of the United States Department of Energy (DOE). The facility is approximately 17,409 acres (74 square miles), and it is located in Kern County, California, about 25 miles southwest of Bakersfield and 100 miles north of Los Angeles in the south central portion of the state. The environmental analysis presented herein is a supplement to the NPR-1 Final Environmental Impact Statement of that was issued by DOE in 1979 (1979 EIS). As such, this document is a Supplemental Environmental Impact Statement (SEIS).

  1. Wall-motion tracking in fetal echocardiography-Influence of frame rate on longitudinal strain analysis assessed by two-dimensional speckle tracking.

    Science.gov (United States)

    Enzensberger, Christian; Achterberg, Friederike; Graupner, Oliver; Wolter, Aline; Herrmann, Johannes; Axt-Fliedner, Roland

    2017-06-01

    Frame rates (FR) used for strain analysis assessed by speckle tracking in fetal echocardiography show a considerable variation. The aim of this study was to investigate the influence of the FR on strain analysis in 2D speckle tracking. Fetal echocardiography was performed prospectively on a Toshiba Aplio 500 system and a Toshiba Artida system, respectively. Based on an apical or basal four-chamber view of the fetal heart, cine loops were stored with a FR of 30 fps (Aplio 500) and 60 fps (Artida/Aplio 500). For both groups (30fps and 60fps), global and segmental longitudinal peak systolic strain (LPSS) values of both, left (LV) and right ventricle (RV), were assessed by 2D wall-motion tracking. A total of 101 fetuses, distributed to three study groups, were included. The mean gestational age was 25.2±5.0 weeks. Mean global LPSS values for RV in the 30 fps group and in the 60 fps group were -16.07% and -16.47%, respectively. Mean global LPSS values for LV in the 30 fps group and in the 60 fps group were -17.54% and -17.06%, respectively. Comparing global and segmental LPSS values of both, the RV and LV, did not show any statistically significant differences within the two groups. Performance of myocardial 2D strain analysis by wall-motion tracking was feasible with 30 and 60 fps. Obtained global and segmental LPSS values of both ventricles were relatively independent from acquisition rate. © 2017, Wiley Periodicals, Inc.

  2. Maximum Plant Uptakes for Water, Nutrients, and Oxygen Are Not Always Met by Irrigation Rate and Distribution in Water-based Cultivation Systems.

    Science.gov (United States)

    Blok, Chris; Jackson, Brian E; Guo, Xianfeng; de Visser, Pieter H B; Marcelis, Leo F M

    2017-01-01

    Growing on rooting media other than soils in situ -i.e., substrate-based growing- allows for higher yields than soil-based growing as transport rates of water, nutrients, and oxygen in substrate surpass those in soil. Possibly water-based growing allows for even higher yields as transport rates of water and nutrients in water surpass those in substrate, even though the transport of oxygen may be more complex. Transport rates can only limit growth when they are below a rate corresponding to maximum plant uptake. Our first objective was to compare Chrysanthemum growth performance for three water-based growing systems with different irrigation. We compared; multi-point irrigation into a pond (DeepFlow); one-point irrigation resulting in a thin film of running water (NutrientFlow) and multi-point irrigation as droplets through air (Aeroponic). Second objective was to compare press pots as propagation medium with nutrient solution as propagation medium. The comparison included DeepFlow water-rooted cuttings with either the stem 1 cm into the nutrient solution or with the stem 1 cm above the nutrient solution. Measurements included fresh weight, dry weight, length, water supply, nutrient supply, and oxygen levels. To account for differences in radiation sum received, crop performance was evaluated with Radiation Use Efficiency (RUE) expressed as dry weight over sum of Photosynthetically Active Radiation. The reference, DeepFlow with substrate-based propagation, showed the highest RUE, even while the oxygen supply provided by irrigation was potentially growth limiting. DeepFlow with water-based propagation showed 15-17% lower RUEs than the reference. NutrientFlow showed 8% lower RUE than the reference, in combination with potentially limiting irrigation supply of nutrients and oxygen. Aeroponic showed RUE levels similar to the reference and Aeroponic had non-limiting irrigation supply of water, nutrients, and oxygen. Water-based propagation affected the subsequent

  3. GAS SURFACE DENSITY, STAR FORMATION RATE SURFACE DENSITY, AND THE MAXIMUM MASS OF YOUNG STAR CLUSTERS IN A DISK GALAXY. II. THE GRAND-DESIGN GALAXY M51

    International Nuclear Information System (INIS)

    González-Lópezlira, Rosa A.; Pflamm-Altenburg, Jan; Kroupa, Pavel

    2013-01-01

    We analyze the relationship between maximum cluster mass and surface densities of total gas (Σ gas ), molecular gas (Σ H 2 ), neutral gas (Σ H I ), and star formation rate (Σ SFR ) in the grand-design galaxy M51, using published gas data and a catalog of masses, ages, and reddenings of more than 1800 star clusters in its disk, of which 223 are above the cluster mass distribution function completeness limit. By comparing the two-dimensional distribution of cluster masses and gas surface densities, we find for clusters older than 25 Myr that M 3rd ∝Σ H I 0.4±0.2 , whereM 3rd is the median of the five most massive clusters. There is no correlation withΣ gas ,Σ H2 , orΣ SFR . For clusters younger than 10 Myr, M 3rd ∝Σ H I 0.6±0.1 and M 3rd ∝Σ gas 0.5±0.2 ; there is no correlation with either Σ H 2 orΣ SFR . The results could hardly be more different from those found for clusters younger than 25 Myr in M33. For the flocculent galaxy M33, there is no correlation between maximum cluster mass and neutral gas, but we have determined M 3rd ∝Σ gas 3.8±0.3 , M 3rd ∝Σ H 2 1.2±0.1 , and M 3rd ∝Σ SFR 0.9±0.1 . For the older sample in M51, the lack of tight correlations is probably due to the combination of strong azimuthal variations in the surface densities of gas and star formation rate, and the cluster ages. These two facts mean that neither the azimuthal average of the surface densities at a given radius nor the surface densities at the present-day location of a stellar cluster represent the true surface densities at the place and time of cluster formation. In the case of the younger sample, even if the clusters have not yet traveled too far from their birth sites, the poor resolution of the radio data compared to the physical sizes of the clusters results in measuredΣ that are likely quite diluted compared to the actual densities relevant for the formation of the clusters.

  4. Fragile-to-fragile liquid transition at Tg and stable-glass phase nucleation rate maximum at the Kauzmann temperature TK

    International Nuclear Information System (INIS)

    Tournier, Robert F.

    2014-01-01

    An undercooled liquid is unstable. The driving force of the glass transition at T g is a change of the undercooled-liquid Gibbs free energy. The classical Gibbs free energy change for a crystal formation is completed including an enthalpy saving. The crystal growth critical nucleus is used as a probe to observe the Laplace pressure change Δp accompanying the enthalpy change −V m ×Δp at T g where V m is the molar volume. A stable glass–liquid transition model predicts the specific heat jump of fragile liquids at T≤T g , the Kauzmann temperature T K where the liquid entropy excess with regard to crystal goes to zero, the equilibrium enthalpy between T K and T g , the maximum nucleation rate at T K of superclusters containing magic atom numbers, and the equilibrium latent heats at T g and T K . Strong-to-fragile and strong-to-strong liquid transitions at T g are also described and all their thermodynamic parameters are determined from their specific heat jumps. The existence of fragile liquids quenched in the amorphous state, which do not undergo liquid–liquid transition during heating preceding their crystallization, is predicted. Long ageing times leading to the formation at T K of a stable glass composed of superclusters containing up to 147 atom, touching and interpenetrating, are evaluated from nucleation rates. A fragile-to-fragile liquid transition occurs at T g without stable-glass formation while a strong glass is stable after transition

  5. The resource theory of quantum reference frames: manipulations and monotones

    International Nuclear Information System (INIS)

    Gour, Gilad; Spekkens, Robert W

    2008-01-01

    Every restriction on quantum operations defines a resource theory, determining how quantum states that cannot be prepared under the restriction may be manipulated and used to circumvent the restriction. A superselection rule (SSR) is a restriction that arises through the lack of a classical reference frame and the states that circumvent it (the resource) are quantum reference frames. We consider the resource theories that arise from three types of SSRs, associated respectively with lacking: (i) a phase reference, (ii) a frame for chirality, and (iii) a frame for spatial orientation. Focusing on pure unipartite quantum states (and in some cases restricting our attention even further to subsets of these), we explore single-copy and asymptotic manipulations. In particular, we identify the necessary and sufficient conditions for a deterministic transformation between two resource states to be possible and, when these conditions are not met, the maximum probability with which the transformation can be achieved. We also determine when a particular transformation can be achieved reversibly in the limit of arbitrarily many copies and find the maximum rate of conversion. A comparison of the three resource theories demonstrates that the extent to which resources can be interconverted decreases as the strength of the restriction increases. Along the way, we introduce several measures of frameness and prove that these are monotonically non-increasing under various classes of operations that are permitted by the SSR

  6. Evaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate

    Directory of Open Access Journals (Sweden)

    Chiba Shigeru

    2007-09-01

    Full Text Available Abstract Background Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data. Methods An experiment was carried out in which the same video image was presented to human subjects three times. We evaluated changes of the intensity of motion sickness they suffered from by a subjective score and the physiological index ρmax, which is defined as the maximum cross-correlation coefficient between heart rate and pulse wave transmission time and is considered to reflect the autonomic nervous activity. Results The results showed adaptation to visually-induced motion sickness by the repetitive presentation of the same image both in the subjective and the objective indices. However, there were some subjects whose intensity of sickness increased. Thus, it was possible to know the part in the video image which related to motion sickness by analyzing changes in ρmax with time. Conclusion The physiological index, ρmax, will be a good index for assessing the adaptation process to visually induced motion sickness and may be useful in checking the safety of rehabilitation systems with new image technologies.

  7. SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Han, B; Xing, L; Wang, L

    2016-01-01

    Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient

  8. Regional Inversion of the Maximum Carboxylation Rate (Vcmax) through the Sunlit Light Use Efficiency Estimated Using the Corrected Photochemical Reflectance Ratio Derived from MODIS Data

    Science.gov (United States)

    Zheng, T.; Chen, J. M.

    2016-12-01

    The maximum carboxylation rate (Vcmax), despite its importance in terrestrial carbon cycle modelling, remains challenging to obtain for large scales. In this study, an attempt has been made to invert the Vcmax using the gross primary productivity from sunlit leaves (GPPsun) with the physiological basis that the photosynthesis rate for leaves exposed to high solar radiation is mainly determined by the Vcmax. Since the GPPsun can be calculated through the sunlit light use efficiency (ɛsun), the main focus becomes the acquisition of ɛsun. Previous studies using site level reflectance observations have shown the ability of the photochemical reflectance ratio (PRR, defined as the ratio between the reflectance from an effective band centered around 531nm and a reference band) in tracking the variation of ɛsun for an evergreen coniferous stand and a deciduous broadleaf stand separately and the potential of a NDVI corrected PRR (NPRR, defined as the product of NDVI and PRR) in producing a general expression to describe the NPRR-ɛsun relationship across different plant function types. In this study, a significant correlation (R2 = 0.67, p<0.001) between the MODIS derived NPRR and the site level ɛsun calculated using flux data for four Canadian flux sites has been found for the year 2010. For validation purpose, the ɛsun in 2009 for the same sites are calculated using the MODIS NPRR and the expression from 2010. The MODIS derived ɛsun matches well with the flux calculated ɛsun (R2 = 0.57, p<0.001). Same expression has then been applied over a 217 × 193 km area in Saskatchewan, Canada to obtain the ɛsun and thus GPPsun for the region during the growing season in 2008 (day 150 to day 260). The Vcmax for the region is inverted using the GPPsun and the result is validated at three flux sites inside the area. The results show that the approach is able to obtain good estimations of Vcmax values with R2 = 0.68 and RMSE = 8.8 μmol m-2 s-1.

  9. On frame multiresolution analysis

    DEFF Research Database (Denmark)

    Christensen, Ole

    2003-01-01

    We use the freedom in frame multiresolution analysis to construct tight wavelet frames (even in the case where the refinable function does not generate a tight frame). In cases where a frame multiresolution does not lead to a construction of a wavelet frame we show how one can nevertheless...

  10. Nonmonotonic belief state frames and reasoning frames

    NARCIS (Netherlands)

    Engelfriet, J.; Herre, H.; Treur, J.

    1995-01-01

    In this paper five levels of specification of nonmonotonic reasoning are distinguished. The notions of semantical frame, belief state frame and reasoning frame are introduced and used as a semantical basis for the first three levels. Moreover, the semantical connections between the levels are

  11. Optical loop framing

    International Nuclear Information System (INIS)

    Kalibjian, R.; Chong, Y.P.; Prono, D.S.; Cavagnolo, H.R.

    1984-06-01

    The ATA provides an electron beam pulse of 70-ns duration at a 1-Hz rate. Our present optical diagnostics technique involve the imaging of the visible light generated by the beam incident onto the plant of a thin sheet of material. It has already been demonstrated that the light generated has a sufficiently fast temporal reponse in performing beam diagnostics. Notwithstanding possible beam emittance degradation due to scattering in the thin sheet, the observation of beam spatial profiles with relatively high efficiencies has provided data complementary to that obtained from beam wall current monitors and from various x-ray probes and other electrical probes. The optical image sensor consists of a gated, intensified television system. The gate pulse of the image intensifier can be appropriately delayed to give frames that are time-positioned from the head to the tail of the beam with a minimum gate time of 5-ns. The spatial correlation of the time frames from pulse to pulse is very good for a stable electron beam; however, when instabilities do occur, it is difficult to properly assess the spatial composition of the head and the tail of the beam on a pulse-to-pulse basis. Multiple gating within a pulse duration becomes desirable but cannot be performed because the recycle time (20-ms) of the TV system is much longer than the beam pulse. For this reason we have developed an optical-loop framing technique that will allow the recording of two frames within one pulse duration with our present gated/intensified TV system

  12. Prime tight frames

    DEFF Research Database (Denmark)

    Lemvig, Jakob; Miller, Christopher; Okoudjou, Kasso A.

    2014-01-01

    to suggest effective analysis and synthesis computation strategies for such frames. Finally, we describe all prime frames constructed from the spectral tetris method, and, as a byproduct, we obtain a characterization of when the spectral tetris construction works for redundancies below two.......We introduce a class of finite tight frames called prime tight frames and prove some of their elementary properties. In particular, we show that any finite tight frame can be written as a union of prime tight frames. We then characterize all prime harmonic tight frames and use thischaracterization...

  13. Changing quantum reference frames

    OpenAIRE

    Palmer, Matthew C.; Girelli, Florian; Bartlett, Stephen D.

    2013-01-01

    We consider the process of changing reference frames in the case where the reference frames are quantum systems. We find that, as part of this process, decoherence is necessarily induced on any quantum system described relative to these frames. We explore this process with examples involving reference frames for phase and orientation. Quantifying the effect of changing quantum reference frames serves as a first step in developing a relativity principle for theories in which all objects includ...

  14. Pseudo-entanglement evaluated in noninertial frames

    International Nuclear Information System (INIS)

    Mehri-Dehnavi, Hossein; Mirza, Behrouz; Mohammadzadeh, Hosein; Rahimi, Robabeh

    2011-01-01

    Research highlights: → We study pseudo-entanglement in noninertial frames. → We examine different measures of entanglement and nonclassical correlation for the state. → We find the threshold for entanglement is changed in noninertial frames. → We also describe the behavior of local unitary classes of states in noninertial frames. - Abstract: We study quantum discord, in addition to entanglement, of bipartite pseudo-entanglement in noninertial frames. It is shown that the entanglement degrades from its maximum value in a stationary frame to a minimum value in an infinite accelerating frame. There is a critical region found in which, for particular cases, entanglement of states vanishes for certain accelerations. The quantum discord of pseudo-entanglement decreases by increasing the acceleration. Also, for a physically inaccessible region, entanglement and nonclassical correlation are evaluated and shown to match the corresponding values of the physically accessible region for an infinite acceleration.

  15. Maximum power point tracking

    International Nuclear Information System (INIS)

    Enslin, J.H.R.

    1990-01-01

    A well engineered renewable remote energy system, utilizing the principal of Maximum Power Point Tracking can be m ore cost effective, has a higher reliability and can improve the quality of life in remote areas. This paper reports that a high-efficient power electronic converter, for converting the output voltage of a solar panel, or wind generator, to the required DC battery bus voltage has been realized. The converter is controlled to track the maximum power point of the input source under varying input and output parameters. Maximum power point tracking for relative small systems is achieved by maximization of the output current in a battery charging regulator, using an optimized hill-climbing, inexpensive microprocessor based algorithm. Through practical field measurements it is shown that a minimum input source saving of 15% on 3-5 kWh/day systems can easily be achieved. A total cost saving of at least 10-15% on the capital cost of these systems are achievable for relative small rating Remote Area Power Supply systems. The advantages at larger temperature variations and larger power rated systems are much higher. Other advantages include optimal sizing and system monitor and control

  16. Maximum Plant Uptakes for Water, Nutrients, and Oxygen Are Not Always Met by Irrigation Rate and Distribution in Water-based Cultivation Systems

    NARCIS (Netherlands)

    Blok, Chris; Jackson, Brian E.; Guo, Xianfeng; Visser, De Pieter H.B.; Marcelis, Leo F.M.

    2017-01-01

    Growing on rooting media other than soils in situ -i.e., substrate-based growing- allows for higher yields than soil-based growing as transport rates of water, nutrients, and oxygen in substrate surpass those in soil. Possibly water-based growing allows for even higher yields as transport rates of

  17. Another frame, another game? : Explaining framing effects in economic games

    NARCIS (Netherlands)

    Gerlach, Philipp; Jaeger, B.; Hopfensitz, A.; Lori, E.

    2016-01-01

    Small changes in the framing of games (i.e., the way in which the game situation is described to participants) can have large effects on players' choices. For example, referring to a prisoner's dilemma game as the "Community Game" as opposed to the "Wall Street Game" can double the cooperation rate

  18. Effect of contraction mode of slow-speed resistance training on the maximum rate of force development in the human quadriceps

    DEFF Research Database (Denmark)

    Blazevich, Anthony J; Horne, Sara; Cannavan, Dale

    2008-01-01

    This study examined the effects of slow-speed resistance training involving concentric (CON, n = 10) versus eccentric (ECC, n = 11) single-joint muscle contractions on contractile rate of force development (RFD) and neuromuscular activity (EMG), and its maintenance through detraining. Isokinetic...

  19. Voluntary drive-dependent changes in vastus lateralis motor unit firing rates during a sustained isometric contraction at 50% of maximum knee extension force.

    NARCIS (Netherlands)

    de Ruiter, C.J.; Elzinga, M.J.; Verdijk, PW; van Mechelen, W.; de Haan, A.

    2004-01-01

    The purpose of the present study was to relate the expected inter-subject variability in voluntary drive of the knee extensor muscles during a sustained isometric contraction to the changes in firing rates of single motor units. Voluntary activation, as established with super-imposed electrical

  20. Making students' frames explicit

    DEFF Research Database (Denmark)

    Nielsen, Louise Møller; Hansen, Poul Henrik Kyvsgaard

    2016-01-01

    Framing is a vital part of the design and innovation process. Frames are cognitive shortcuts (i.e. metaphors) that enable designers to connect insights about i.e. market opportunities and users needs with a set of solution principles and to test if this connection makes sense. Until now, framing...

  1. Geometric Properties of Grassmannian Frames for and

    Directory of Open Access Journals (Sweden)

    Benedetto John J

    2006-01-01

    Full Text Available Grassmannian frames are frames satisfying a min-max correlation criterion. We translate a geometrically intuitive approach for two- and three-dimensional Euclidean space ( and into a new analytic method which is used to classify many Grassmannian frames in this setting. The method and associated algorithm decrease the maximum frame correlation, and hence give rise to the construction of specific examples of Grassmannian frames. Many of the results are known by other techniques, and even more generally, so that this paper can be viewed as tutorial. However, our analytic method is presented with the goal of developing it to address unresovled problems in -dimensional Hilbert spaces which serve as a setting for spherical codes, erasure channel modeling, and other aspects of communications theory.

  2. Multivariate wavelet frames

    CERN Document Server

    Skopina, Maria; Protasov, Vladimir

    2016-01-01

    This book presents a systematic study of multivariate wavelet frames with matrix dilation, in particular, orthogonal and bi-orthogonal bases, which are a special case of frames. Further, it provides algorithmic methods for the construction of dual and tight wavelet frames with a desirable approximation order, namely compactly supported wavelet frames, which are commonly required by engineers. It particularly focuses on methods of constructing them. Wavelet bases and frames are actively used in numerous applications such as audio and graphic signal processing, compression and transmission of information. They are especially useful in image recovery from incomplete observed data due to the redundancy of frame systems. The construction of multivariate wavelet frames, especially bases, with desirable properties remains a challenging problem as although a general scheme of construction is well known, its practical implementation in the multidimensional setting is difficult. Another important feature of wavelet is ...

  3. Maximum Urine Flow Rate of Less than 15ml/Sec Increasing Risk of Urine Retention and Prostate Surgery among Patients with Alpha-1 Blockers: A 10-Year Follow Up Study.

    Directory of Open Access Journals (Sweden)

    Hsin-Ho Liu

    Full Text Available The aim of this study was to determine the subsequent risk of acute urine retention and prostate surgery in patients receiving alpha-1 blockers treatment and having a maximum urinary flow rate of less than 15ml/sec.We identified patients who were diagnosed with benign prostate hyperplasia (BPH and had a maximum uroflow rate of less than 15ml/sec between 1 January, 2002 to 31 December, 2011 from Taiwan's National Health Insurance Research Database into study group (n = 303. The control cohort included four BPH/LUTS patients without 5ARI used for each study group, randomly selected from the same dataset (n = 1,212. Each patient was monitored to identify those who subsequently developed prostate surgery and acute urine retention.Prostate surgery and acute urine retention are detected in 5.9% of control group and 8.3% of study group during 10-year follow up. Compared with the control group, there was increase in the risk of prostate surgery and acute urine retention in the study group (HR = 1.83, 95% CI: 1.16 to 2.91 after adjusting for age, comorbidities, geographic region and socioeconomic status.Maximum urine flow rate of less than 15ml/sec is a risk factor of urinary retention and subsequent prostate surgery in BPH patients receiving alpha-1 blocker therapy. This result can provide a reference for clinicians.

  4. Changing climate, changing frames

    International Nuclear Information System (INIS)

    Vink, Martinus J.; Boezeman, Daan; Dewulf, Art; Termeer, Catrien J.A.M.

    2013-01-01

    Highlights: ► We show development of flood policy frames in context of climate change attention. ► Rising attention on climate change influences traditional flood policy framing. ► The new framing employs global-scale scientific climate change knowledge. ► With declining attention, framing disregards climate change, using local knowledge. ► We conclude that frames function as sensemaking devices selectively using knowledge. -- Abstract: Water management and particularly flood defence have a long history of collective action in low-lying countries like the Netherlands. The uncertain but potentially severe impacts of the recent climate change issue (e.g. sea level rise, extreme river discharges, salinisation) amplify the wicked and controversial character of flood safety policy issues. Policy proposals in this area generally involve drastic infrastructural works and long-term investments. They face the difficult challenge of framing problems and solutions in a publicly acceptable manner in ever changing circumstances. In this paper, we analyse and compare (1) how three key policy proposals publicly frame the flood safety issue, (2) the knowledge referred to in the framing and (3) how these frames are rhetorically connected or disconnected as statements in a long-term conversation. We find that (1) framings of policy proposals differ in the way they depict the importance of climate change, the relevant timeframe and the appropriate governance mode; (2) knowledge is selectively mobilised to underpin the different frames and (3) the frames about these proposals position themselves against the background of the previous proposals through rhetorical connections and disconnections. Finally, we discuss how this analysis hints at the importance of processes of powering and puzzling that lead to particular framings towards the public at different historical junctures

  5. Characterization of the heart rate curve during a maximum incremental test on a treadmill. DOI: 10.5007/1980-0037.2011v13n4p285

    Directory of Open Access Journals (Sweden)

    Eduardo Marcel Fernandes Nascimento

    2011-08-01

    Full Text Available The objective of this study was to analyze the heart rate (HR profile plotted against incremental workloads (IWL during a treadmill test using three mathematical models [linear, linear with 2 segments (Lin2, and sigmoidal], and to determine the best model for the identification of the HR threshold that could be used as a predictor of ventilatory thresholds (VT1 and VT2. Twenty-two men underwent a treadmill incremental test (retest group: n=12 at an initial speed of 5.5 km.h-1, with increments of 0.5 km.h-1 at 1-min intervals until exhaustion. HR and gas exchange were continuously measured and subsequently converted to 5-s and 20-s averages, respectively. The best model was chosen based on residual sum of squares and mean square error. The HR/IWL ratio was better fitted with the Lin2 model in the test and retest groups (p0.05. During a treadmill incremental test, the HR/IWL ratio seems to be better fitted with a Lin2 model, which permits to determine the HR threshold that coincides with VT1.

  6. Nonsymmetric entropy and maximum nonsymmetric entropy principle

    International Nuclear Information System (INIS)

    Liu Chengshi

    2009-01-01

    Under the frame of a statistical model, the concept of nonsymmetric entropy which generalizes the concepts of Boltzmann's entropy and Shannon's entropy, is defined. Maximum nonsymmetric entropy principle is proved. Some important distribution laws such as power law, can be derived from this principle naturally. Especially, nonsymmetric entropy is more convenient than other entropy such as Tsallis's entropy in deriving power laws.

  7. Career Compromises: Framings and Their Implications.

    Science.gov (United States)

    Gati, Itamar; Houminer, Daphna; Aviram, Tamar

    1998-01-01

    Career compromise was investigated in three framings (alternatives, aspect importance, within-aspect preference). Young adults and school counselors rated hypothetical stories. Results of four studies with different designs (Average N=106) supported the hypothesis. The alternatives framing was associated with greater compromise and decision…

  8. Clear as Mud: Changes in Paleoshelf Environments and Deposition Rates at Medford, New Jersey during the Paleocene-Eocene Thermal Maximum

    Science.gov (United States)

    Podrecca, L.; Miller, K. G.; Wright, J. D.; Browning, J. V.; Emge, T.

    2017-12-01

    The Paleocene-Eocene boundary marks a time of swift global climatic change. Constraining the timeframe of this event is a first order question necessary for ascertaining the origin of the event and the potential for its use as an analog for modern climate change. The New Jersey shelf sediments of the Marlboro Formation records this time period with exceptionally thick (5-15m) records of the period of global low carbon isotopic values ("the core") which requires minimum sedimentation rates of 10's cm/kyr. Rhythmic layers have been previously reported from Wilson Lake & Millville, NJ (IODP Leg 174AX). These structures coined "laminae couplets" consist of semi-periodic 1-2mm thick raised laminations separated by matrix of varying width (averaging 1.8cm). These have been dismissed as artifacts of drilling "biscuits". We report here on a series of shallow auger cores drilled on a transect at Medford, NJ, without using drilling fluid. These cores also show a similar set of structures on the 2cm scale verifying that they are primary depositional features. The mm width laminae in the auger core show remarkable swelling within minutes of splitting. XRD, XRF, bulk carbonate geochemistry, and grain size analysis have been determined at regular depth intervals throughout the core. We have analyzed differences in these parameters between the laminae and interbedded matrix material, as well as across the transect as a whole. In general, the Marlboro formation at this updip location consists of micaceous, lignitic, very clayey silt (mean size 6 micrometers) with occasional organic debris indicating proximal deposition from a fluvial system. Paleodepth of 40m and normal marine salinities are estimated using a paleoslope model and the presence of common though not abundant planktonic foraminifera. We discuss a model of deposition for the Marlboro Formation as fluid mud (nearbed suspension flows) associated with the "Appalachian Amazon" alluding toward the finer grained inter

  9. Frame on frames: an annotated bibliography

    International Nuclear Information System (INIS)

    Wright, T.; Tsao, H.J.

    1983-01-01

    The success or failure of any sample survey of a finite population is largely dependent upon the condition and adequacy of the list or frame from which the probability sample is selected. Much of the published survey sampling related work has focused on the measurement of sampling errors and, more recently, on nonsampling errors to a lesser extent. Recent studies on data quality for various types of data collection systems have revealed that the extent of the nonsampling errors far exceeds that of the sampling errors in many cases. While much of this nonsampling error, which is difficult to measure, can be attributed to poor frames, relatively little effort or theoretical work has focused on this contribution to total error. The objective of this paper is to present an annotated bibliography on frames with the hope that it will bring together, for experimenters, a number of suggestions for action when sampling from imperfect frames and that more attention will be given to this area of survey methods research

  10. Approximate maximum parsimony and ancestral maximum likelihood.

    Science.gov (United States)

    Alon, Noga; Chor, Benny; Pardi, Fabio; Rapoport, Anat

    2010-01-01

    We explore the maximum parsimony (MP) and ancestral maximum likelihood (AML) criteria in phylogenetic tree reconstruction. Both problems are NP-hard, so we seek approximate solutions. We formulate the two problems as Steiner tree problems under appropriate distances. The gist of our approach is the succinct characterization of Steiner trees for a small number of leaves for the two distances. This enables the use of known Steiner tree approximation algorithms. The approach leads to a 16/9 approximation ratio for AML and asymptotically to a 1.55 approximation ratio for MP.

  11. Maximum permissible dose

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This chapter presents a historic overview of the establishment of radiation guidelines by various national and international agencies. The use of maximum permissible dose and maximum permissible body burden limits to derive working standards is discussed

  12. Tuning of Synchronous-Frame PI Current Controllers in Grid-Connected Converters Operating at a Low Sampling Rate by MIMO Root Locus

    DEFF Research Database (Denmark)

    Fernandez, Francisco Daniel Freijedo; Vidal, Ana; Yepes, Alejandro G.

    2015-01-01

    Current controller performance is key in gridconnected power converters for renewable energy applications. In this context, a challenging scenario is arising in multi-MW wind turbines, where sampling and switching frequencies tend to be lower and lower as power ratings increase. This strongly...... of the system are calculated with explicit consideration of time-delay and cross-coupling terms, two factors which clearly impair the system dynamics when considering a low sampling frequency. The proposed methodology is summarized as follows. Firstly, the plant and controller matrices are modeled in state......-space. Subsequently, the characteristic polynomial of the closed-loop system is obtained and a computer-aided parametric analysis is performed to calculate the MIMO root locus as a function of the control gain. By its inspection, it is possible to identify the gain which minimizes the current closed-loop time...

  13. Modern frame structure buildings

    Directory of Open Access Journals (Sweden)

    В. М. Першаков

    2013-07-01

    Full Text Available The article deals with the design, construction and implementation of reinforced concrete frame structures with span 18, 21 m for agricultural production buildings, hall-premises of public buildings and buildings of agricultural aviation. Structures are prefabricated frame buildings and have such advantages as large space inside the structure and lower cost compared with other facilities with same purpose

  14. Multimodal news framing effects

    NARCIS (Netherlands)

    Powell, T.E.

    2017-01-01

    Visuals in news media play a vital role in framing citizens’ political preferences. Yet, compared to the written word, visual images are undervalued in political communication research. Using framing theory, this thesis redresses the balance by studying the combined, or multimodal, effects of visual

  15. The Frame Game

    Science.gov (United States)

    Edwards, Michael Todd; Cox, Dana C.

    2011-01-01

    In this article, the authors explore framing, a non-multiplicative technique commonly employed by students as they construct similar shapes. When students frame, they add (or subtract) a "border" of fixed width about a geometric object. Although the approach does not yield similar shapes in general, the mathematical underpinnings of…

  16. Traditional timber frames

    NARCIS (Netherlands)

    Jorissen, A.J.M.; Hamer, den J.; Leijten, A.J.M.; Salenikovich, A.

    2014-01-01

    Due to new possibilities traditional timber framing has become increasingly popular since the beginning of the 21e century. Although traditional timber framing has been used for centuries, the expected mechanical behaviour is not dealt with in great detail in building codes, guidelines or text

  17. Optimal primitive reference frames

    International Nuclear Information System (INIS)

    Jennings, David

    2011-01-01

    We consider the smallest possible directional reference frames allowed and determine the best one can ever do in preserving quantum information in various scenarios. We find that for the preservation of a single spin state, two orthogonal spins are optimal primitive reference frames; and in a product state, they do approximately 22% as well as an infinite-sized classical frame. By adding a small amount of entanglement to the reference frame, this can be raised to 2(2/3) 5 =26%. Under the different criterion of entanglement preservation, a very similar optimal reference frame is found; however, this time it is for spins aligned at an optimal angle of 87 deg. In this case 24% of the negativity is preserved. The classical limit is considered numerically, and indicates under the criterion of entanglement preservation, that 90 deg. is selected out nonmonotonically, with a peak optimal angle of 96.5 deg. for L=3 spins.

  18. Dragging of inertial frames.

    Science.gov (United States)

    Ciufolini, Ignazio

    2007-09-06

    The origin of inertia has intrigued scientists and philosophers for centuries. Inertial frames of reference permeate our daily life. The inertial and centrifugal forces, such as the pull and push that we feel when our vehicle accelerates, brakes and turns, arise because of changes in velocity relative to uniformly moving inertial frames. A classical interpretation ascribed these forces to acceleration relative to some absolute frame independent of the cosmological matter, whereas an opposite view related them to acceleration relative to all the masses and 'fixed stars' in the Universe. An echo and partial realization of the latter idea can be found in Einstein's general theory of relativity, which predicts that a spinning mass will 'drag' inertial frames along with it. Here I review the recent measurements of frame dragging using satellites orbiting Earth.

  19. Quantitative rotating frame relaxometry methods in MRI.

    Science.gov (United States)

    Gilani, Irtiza Ali; Sepponen, Raimo

    2016-06-01

    Macromolecular degeneration and biochemical changes in tissue can be quantified using rotating frame relaxometry in MRI. It has been shown in several studies that the rotating frame longitudinal relaxation rate constant (R1ρ ) and the rotating frame transverse relaxation rate constant (R2ρ ) are sensitive biomarkers of phenomena at the cellular level. In this comprehensive review, existing MRI methods for probing the biophysical mechanisms that affect the rotating frame relaxation rates of the tissue (i.e. R1ρ and R2ρ ) are presented. Long acquisition times and high radiofrequency (RF) energy deposition into tissue during the process of spin-locking in rotating frame relaxometry are the major barriers to the establishment of these relaxation contrasts at high magnetic fields. Therefore, clinical applications of R1ρ and R2ρ MRI using on- or off-resonance RF excitation methods remain challenging. Accordingly, this review describes the theoretical and experimental approaches to the design of hard RF pulse cluster- and adiabatic RF pulse-based excitation schemes for accurate and precise measurements of R1ρ and R2ρ . The merits and drawbacks of different MRI acquisition strategies for quantitative relaxation rate measurement in the rotating frame regime are reviewed. In addition, this review summarizes current clinical applications of rotating frame MRI sequences. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Complementary frame reconstruction: a low-biased dynamic PET technique for low count density data in projection space

    International Nuclear Information System (INIS)

    Hong, Inki; Cho, Sanghee; Michel, Christian J; Casey, Michael E; Schaefferkoetter, Joshua D

    2014-01-01

    A new data handling method is presented for improving the image noise distribution and reducing bias when reconstructing very short frames from low count dynamic PET acquisition. The new method termed ‘Complementary Frame Reconstruction’ (CFR) involves the indirect formation of a count-limited emission image in a short frame through subtraction of two frames with longer acquisition time, where the short time frame data is excluded from the second long frame data before the reconstruction. This approach can be regarded as an alternative to the AML algorithm recently proposed by Nuyts et al, as a method to reduce the bias for the maximum likelihood expectation maximization (MLEM) reconstruction of count limited data. CFR uses long scan emission data to stabilize the reconstruction and avoids modification of algorithms such as MLEM. The subtraction between two long frame images, naturally allows negative voxel values and significantly reduces bias introduced in the final image. Simulations based on phantom and clinical data were used to evaluate the accuracy of the reconstructed images to represent the true activity distribution. Applicability to determine the arterial input function in human and small animal studies is also explored. In situations with limited count rate, e.g. pediatric applications, gated abdominal, cardiac studies, etc., or when using limited doses of short-lived isotopes such as 15 O-water, the proposed method will likely be preferred over independent frame reconstruction to address bias and noise issues. (paper)

  1. Framing effects over time: comparing affective and cognitive news frames

    NARCIS (Netherlands)

    Lecheler, S.; Matthes, J.

    2012-01-01

    A growing number of scholars examine the duration of framing effects. However, duration is likely to differ from frame to frame, depending on how strong a frame is. This strength is likely to be enhanced by adding emotional components to a frame. By means of an experimental survey design (n = 111),

  2. Framing Gangnam Style

    Directory of Open Access Journals (Sweden)

    Hyunsun Catherine Yoon

    2017-08-01

    Full Text Available This paper examines the way in which news about Gangnam Style was framed in the Korean press. First released on 15th July 2012, it became the first video to pass two billion views on YouTube. 400 news articles between July 2012 and March 2013 from two South Korean newspapers - Chosun Ilbo and Hankyoreh were analyzed using the frame analysis method in five categories: industry/economy, globalization, cultural interest, criticism, and competition. The right-left opinion cleavage is important because news frames interact with official discourses, audience frames and prior knowledge which consequently mediate effects on public opinion, policy debates, social movement and individual interpretations. Whilst the existing literature on Gangnam Style took rather holistic approach, this study aimed to fill the lacuna, considering this phenomenon as a dynamic process, by segmenting different stages - recognition, spread, peak and continuation. Both newspapers acknowledged Gangnam Style was an epochal event but their perspectives and news frames were different; globalization frame was most frequently used in Chosun Ilbo whereas cultural interest frame was most often used in Hankyoreh. Although more critical approaches were found in Hankyoreh, reflecting the right-left opinion cleavage, both papers lacked in critical appraisal and analysis of Gangnam Style’s reception in a broader context of the new Korean Wave.

  3. Framing in criminal investigation

    Science.gov (United States)

    2016-01-01

    Failures in criminal investigation may lead to wrongful convictions. Insight in the criminal investigation process is needed to understand how these investigative failures may rise and how measures can contribute to the prevention of this kind of failures. Some of the main findings of an empirical study of the criminal investigation process in four cases of major investigations are presented here. This criminal investigation process is analyzed as a process of framing, using Goffman's framing (Goffman, 1975) and interaction theories (Goffman, 1990). It shows that in addition to framing, other substantive and social factors affect the criminal investigation. PMID:29046594

  4. Global Vertical Reference Frame

    Czech Academy of Sciences Publication Activity Database

    Burša, Milan; Kenyon, S.; Kouba, J.; Šíma, Zdislav; Vatrt, V.; Vojtíšková, M.

    2004-01-01

    Roč. 33, - (2004), s. 404-407 ISSN 1436-3445 Institutional research plan: CEZ:AV0Z1003909 Keywords : geopotential WO * vertical systems * global vertical frame Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  5. TRENDS IN ESTIMATED MIXING DEPTH DAILY MAXIMUMS

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, R; Amy DuPont, A; Robert Kurzeja, R; Matt Parker, M

    2007-11-12

    Mixing depth is an important quantity in the determination of air pollution concentrations. Fireweather forecasts depend strongly on estimates of the mixing depth as a means of determining the altitude and dilution (ventilation rates) of smoke plumes. The Savannah River United States Forest Service (USFS) routinely conducts prescribed fires at the Savannah River Site (SRS), a heavily wooded Department of Energy (DOE) facility located in southwest South Carolina. For many years, the Savannah River National Laboratory (SRNL) has provided forecasts of weather conditions in support of the fire program, including an estimated mixing depth using potential temperature and turbulence change with height at a given location. This paper examines trends in the average estimated mixing depth daily maximum at the SRS over an extended period of time (4.75 years) derived from numerical atmospheric simulations using two versions of the Regional Atmospheric Modeling System (RAMS). This allows for differences to be seen between the model versions, as well as trends on a multi-year time frame. In addition, comparisons of predicted mixing depth for individual days in which special balloon soundings were released are also discussed.

  6. On transforms between Gabor frames and wavelet frames

    DEFF Research Database (Denmark)

    Christensen, Ole; Goh, Say Song

    2013-01-01

    We describe a procedure that enables us to construct dual pairs of wavelet frames from certain dual pairs of Gabor frames. Applying the construction to Gabor frames generated by appropriate exponential Bsplines gives wavelet frames generated by functions whose Fourier transforms are compactly...... supported splines with geometrically distributed knot sequences. There is also a reverse transform, which yields pairs of dual Gabor frames when applied to certain wavelet frames....

  7. Frames for undergraduates

    CERN Document Server

    Han, Deguang; Larson, David; Weber, Eric

    2007-01-01

    Frames for Undergraduates is an undergraduate-level introduction to the theory of frames in a Hilbert space. This book can serve as a text for a special-topics course in frame theory, but it could also be used to teach a second semester of linear algebra, using frames as an application of the theoretical concepts. It can also provide a complete and helpful resource for students doing undergraduate research projects using frames. The early chapters contain the topics from linear algebra that students need to know in order to read the rest of the book. The later chapters are devoted to advanced topics, which allow students with more experience to study more intricate types of frames. Toward that end, a Student Presentation section gives detailed proofs of fairly technical results with the intention that a student could work out these proofs independently and prepare a presentation to a class or research group. The authors have also presented some stories in the Anecdotes section about how this material has moti...

  8. The Effects of Framing Grades on Student Learning and Preferences

    Science.gov (United States)

    Bies-Hernandez, Nicole J.

    2012-01-01

    Two experiments examined whether framing effects, in terms of losses and gains, can be extended to student learning and grading preferences. In Experiment 1, participants rated psychology course syllabi to investigate preferences for differently framed grading systems: a loss versus gain grading system. The results showed a clear framing effect…

  9. Weaving Hilbert space fusion frames

    OpenAIRE

    Neyshaburi, Fahimeh Arabyani; Arefijamaal, Ali Akbar

    2018-01-01

    A new notion in frame theory, so called weaving frames has been recently introduced to deal with some problems in signal processing and wireless sensor networks. Also, fusion frames are an important extension of frames, used in many areas especially for wireless sensor networks. In this paper, we survey the notion of weaving Hilbert space fusion frames. This concept can be had potential applications in wireless sensor networks which require distributed processing using different fusion frames...

  10. A neuroimaging investigation of attribute framing and individual differences

    Science.gov (United States)

    Murch, Kevin B.

    2014-01-01

    Functional magnetic resonance imaging was used to evaluate the neural basis of framing effects. We tested the reflexive and reflective systems model of social cognition as it relates to framing. We also examined the relationships among frame susceptibility, intelligence and personality measures. Participants evaluated whether personal attributes applied to themselves from multiple perspectives and in positive and negative frames. Participants rated whether each statement was descriptive or not and endorsed positive frames more than negative frames. Individual differences on frame decisions enabled us to form high and low frame susceptibility groups. Endorsement of frame-consistent attributes was associated with personality factors, cognitive reflection and intelligence. Reflexive brain regions were associated with positive frames while reflective areas were associated with negative frames. Region of Interest analyses showed that frame-inconsistent responses were associated with increased activation within reflective cognitive control regions including the left dorsolateral prefrontal cortex (PFC), dorsomedial PFC and left ventrolateral PFC. Frame-consistent responses were associated with increased activation in the right orbitofrontal cortex. These results demonstrate that individual differences in frame susceptibility influence personal attribute evaluations. Overall, this study clarifies the neural correlates of the reflective and reflexive systems of social cognition as applied to decisions about social attributions. PMID:23988759

  11. A neuroimaging investigation of attribute framing and individual differences.

    Science.gov (United States)

    Murch, Kevin B; Krawczyk, Daniel C

    2014-10-01

    Functional magnetic resonance imaging was used to evaluate the neural basis of framing effects. We tested the reflexive and reflective systems model of social cognition as it relates to framing. We also examined the relationships among frame susceptibility, intelligence and personality measures. Participants evaluated whether personal attributes applied to themselves from multiple perspectives and in positive and negative frames. Participants rated whether each statement was descriptive or not and endorsed positive frames more than negative frames. Individual differences on frame decisions enabled us to form high and low frame susceptibility groups. Endorsement of frame-consistent attributes was associated with personality factors, cognitive reflection and intelligence. Reflexive brain regions were associated with positive frames while reflective areas were associated with negative frames. Region of Interest analyses showed that frame-inconsistent responses were associated with increased activation within reflective cognitive control regions including the left dorsolateral prefrontal cortex (PFC), dorsomedial PFC and left ventrolateral PFC. Frame-consistent responses were associated with increased activation in the right orbitofrontal cortex. These results demonstrate that individual differences in frame susceptibility influence personal attribute evaluations. Overall, this study clarifies the neural correlates of the reflective and reflexive systems of social cognition as applied to decisions about social attributions. © The Author (2013). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  12. Maximum Acceleration Recording Circuit

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

  13. Operator representations of frames

    DEFF Research Database (Denmark)

    Christensen, Ole; Hasannasab, Marzieh

    2017-01-01

    of the properties of the operator T requires more work. For example it is a delicate issue to obtain a representation with a bounded operator, and the availability of such a representation not only depends on the frame considered as a set, but also on the chosen indexing. Using results from operator theory we show......The purpose of this paper is to consider representations of frames {fk}k∈I in a Hilbert space ℋ of the form {fk}k∈I = {Tkf0}k∈I for a linear operator T; here the index set I is either ℤ or ℒ0. While a representation of this form is available under weak conditions on the frame, the analysis...... that by embedding the Hilbert space ℋ into a larger Hilbert space, we can always represent a frame via iterations of a bounded operator, composed with the orthogonal projection onto ℋ. The paper closes with a discussion of an open problem concerning representations of Gabor frames via iterations of a bounded...

  14. ``Frames of Reference'' revisited

    Science.gov (United States)

    Steyn-Ross, Alistair; Ivey, Donald G.

    1992-12-01

    The PSSC teaching film, ``Frames of Reference,'' was made in 1960, and was one of the first audio-visual attempts at showing how your physical ``point of view,'' or frame of reference, necessarily alters both your perceptions and your observations of motion. The gentle humor and original demonstrations made a lasting impact on many audiences, and with its recent re-release as part of the AAPT Cinema Classics videodisc it is timely that we should review both the message and the methods of the film. An annotated script and photographs from the film are presented, followed by extension material on rotating frames which teachers may find appropriate for use in their classrooms: constructions, demonstrations, an example, and theory.

  15. Maximum Quantum Entropy Method

    OpenAIRE

    Sim, Jae-Hoon; Han, Myung Joon

    2018-01-01

    Maximum entropy method for analytic continuation is extended by introducing quantum relative entropy. This new method is formulated in terms of matrix-valued functions and therefore invariant under arbitrary unitary transformation of input matrix. As a result, the continuation of off-diagonal elements becomes straightforward. Without introducing any further ambiguity, the Bayesian probabilistic interpretation is maintained just as in the conventional maximum entropy method. The applications o...

  16. Maximum power demand cost

    International Nuclear Information System (INIS)

    Biondi, L.

    1998-01-01

    The charging for a service is a supplier's remuneration for the expenses incurred in providing it. There are currently two charges for electricity: consumption and maximum demand. While no problem arises about the former, the issue is more complicated for the latter and the analysis in this article tends to show that the annual charge for maximum demand arbitrarily discriminates among consumer groups, to the disadvantage of some [it

  17. Maximum Entropy in Drug Discovery

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Tseng

    2014-07-01

    Full Text Available Drug discovery applies multidisciplinary approaches either experimentally, computationally or both ways to identify lead compounds to treat various diseases. While conventional approaches have yielded many US Food and Drug Administration (FDA-approved drugs, researchers continue investigating and designing better approaches to increase the success rate in the discovery process. In this article, we provide an overview of the current strategies and point out where and how the method of maximum entropy has been introduced in this area. The maximum entropy principle has its root in thermodynamics, yet since Jaynes’ pioneering work in the 1950s, the maximum entropy principle has not only been used as a physics law, but also as a reasoning tool that allows us to process information in hand with the least bias. Its applicability in various disciplines has been abundantly demonstrated. We give several examples of applications of maximum entropy in different stages of drug discovery. Finally, we discuss a promising new direction in drug discovery that is likely to hinge on the ways of utilizing maximum entropy.

  18. Video frame processor

    International Nuclear Information System (INIS)

    Joshi, V.M.; Agashe, Alok; Bairi, B.R.

    1993-01-01

    This report provides technical description regarding the Video Frame Processor (VFP) developed at Bhabha Atomic Research Centre. The instrument provides capture of video images available in CCIR format. Two memory planes each with a capacity of 512 x 512 x 8 bit data enable storage of two video image frames. The stored image can be processed on-line and on-line image subtraction can also be carried out for image comparisons. The VFP is a PC Add-on board and is I/O mapped within the host IBM PC/AT compatible computer. (author). 9 refs., 4 figs., 19 photographs

  19. What's in a Frame?

    DEFF Research Database (Denmark)

    Holmgreen, Lise-Lotte

    Maintaining a good image and reputation in the eyes of stakeholders is vital to the organisation. Thus, in its corporate communication and discourse the organisation will seek to present or frame itself as favourably as possible while observing regulations stipulating accuracy and precision...... an organisation, and hence in shaping the image projected to the public. Framing is here understood as the selection of ‘some aspects of perceived reality … [making] them more salient in the communication text, in such a way as to promote a particular problem definition, causal interpretation, moral evaluation...

  20. Thinking inside the frame

    DEFF Research Database (Denmark)

    Knudsen, Sanne

    2017-01-01

    directed at the humanities. The purpose of this study is to argue the case for further research of public understanding of the humanities and to take a first step in that direction by presenting a study of the framing of the humanities in Danish print news media. Different framings of the humanities......The humanities, the natural and social sciences all represent advanced and systematic knowledge production—and they all receive public funding for doing so. However, although the field of public understanding of science has been well established for decades, similar research attention has not been...

  1. Framing financial culture

    DEFF Research Database (Denmark)

    Just, Sine Nørholm; Mouton, Nicolaas T.O.

    2014-01-01

    between competing frames leads to the conclusion that this political “blame game” is related to struggles over how to define the scandal, how to conceptualize its causes, and policy recommendations. Banks may have lost the battle of “Liborgate,” but the war over the meaning of financial culture is far...... from over. Originality/value – The paper is theoretically and methodologically original in its combination of the theories of framing and stasis, and it provides analytical insights into how sense is made of financial culture in the wake of the financial crisis....

  2. Timber frame walls

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan de Place; Brandt, Erik

    2010-01-01

    A ventilated cavity is usually considered good practice for removing moisture behind the cladding of timber framed walls. Timber frame walls with no cavity are a logical alternative as they are slimmer and less expensive to produce and besides the risk of a two-sided fire behind the cladding....... It was found that the specific damages made to the vapour barrier as part of the test did not have any provable effect on the moisture content. In general elements with an intact vapour barrier did not show a critical moisture content at the wind barrier after four years of exposure....

  3. Frame scaling function sets and frame wavelet sets in Rd

    International Nuclear Information System (INIS)

    Liu Zhanwei; Hu Guoen; Wu Guochang

    2009-01-01

    In this paper, we classify frame wavelet sets and frame scaling function sets in higher dimensions. Firstly, we obtain a necessary condition for a set to be the frame wavelet sets. Then, we present a necessary and sufficient condition for a set to be a frame scaling function set. We give a property of frame scaling function sets, too. Some corresponding examples are given to prove our theory in each section.

  4. Frames and extension problems I

    DEFF Research Database (Denmark)

    Christensen, Ole

    2014-01-01

    In this article we present a short survey of frame theory in Hilbert spaces. We discuss Gabor frames and wavelet frames and set the stage for a discussion of various extension principles; this will be presented in the article Frames and extension problems II (joint with H.O. Kim and R.Y. Kim)....

  5. Sparse Matrices in Frame Theory

    DEFF Research Database (Denmark)

    Lemvig, Jakob; Krahmer, Felix; Kutyniok, Gitta

    2014-01-01

    Frame theory is closely intertwined with signal processing through a canon of methodologies for the analysis of signals using (redundant) linear measurements. The canonical dual frame associated with a frame provides a means for reconstruction by a least squares approach, but other dual frames...... yield alternative reconstruction procedures. The novel paradigm of sparsity has recently entered the area of frame theory in various ways. Of those different sparsity perspectives, we will focus on the situations where frames and (not necessarily canonical) dual frames can be written as sparse matrices...

  6. The Cage; Framing Dad

    DEFF Research Database (Denmark)

    Kau, Edvin

    2012-01-01

    Unfolding his story very gradually and arousing the viewer’s curiosity, Sitaru invites the audience to investigate the parents’ and the boy’s mutual positions in their small flat, as well as the various layers of their conversations, through such means as framing, editing style, and the use...

  7. Quantum frames of reference

    International Nuclear Information System (INIS)

    Kaufherr, T.

    1981-01-01

    The idea that only relative variables have physical meaning came to be known as Mach's principle. Carrying over this idea to quantum theory, has led to the consideration of finite mass, macroscopic reference frames, relative to which all physical quantities are measured. During the process of measurement, a finite mass observer receives a kickback, and this reaction of the measuring device is not negligible in quantum theory because of the quantization of the action. Hence, the observer himself has to be included in the system that is being considered. Using this as the starting point, a number of thought experiments involving finite mass observers is discussed which have quantum uncertainties in their time or in their position. These thought experiments serve to elucidate in a qualitative way some of the difficulties involved, as well as pointing out a direction to take in seeking solutions to them. When the discussion is extended to include more than one observer, the question of the covariance of the theory immediately arises. Because none of the frames of reference should be preferred, the theory should be covariant. This demand expresses an equivalence principle which here is extended to include reference frames which are in quantum uncertainties relative to each other. Formulating the problem in terms of canonical variables, the ensueing free Hamiltonian contains vector and scalar potentials which represent the kick that the reference frame receives during measurement. These are essentially gravitational type potentials, resulting, as it were, from the extension of the equivalence principle into the quantum domain

  8. Framing the Oscars live

    DEFF Research Database (Denmark)

    Haastrup, Helle Kannik

    2016-01-01

    How is the global media event of the Oscars localised through the talk show on Danish television? How are both the mediated film star and the special brand of Hollywood celebrity culture addressed by the cultural intermediaries in the Danish framing? These are the questions I propose to answer...

  9. Quotation and Framing

    DEFF Research Database (Denmark)

    Petersen, Nils Holger

    2010-01-01

    . In Black Angels the composer – among other well-known pieces of music – quotes the medieval dies irae sequence and the second movement of Schubert’s string quartet in D minor (D. 810). The musical and intermedial references are framed with striking modernistic sounds exploring instrumental possibilities...

  10. Framing ‘fracking’

    NARCIS (Netherlands)

    Williams, Laurence; Macnaghten, Philip; Davies, Richard; Curtis, Sarah

    2017-01-01

    The prospect of fracking in the United Kingdom has been accompanied by significant public unease. We outline how the policy debate is being framed by UK institutional actors, finding evidence of a dominant discourse in which the policy approach is defined through a deficit model of public

  11. Framing Canadian federalism

    National Research Council Canada - National Science Library

    Saywell, John; Anastakis, Dimitry; Bryden, Penny E

    2009-01-01

    ... the pervasive effects that federalism has on Canadian politics, economics, culture, and history, and provide a detailed framework in which to understand contemporary federalism. Written in honour of John T. Saywell's half-century of accomplished and influential scholarly work and teaching, Framing Canadian Federalism is a timely and fitting t...

  12. Global Vertical Reference Frame

    Czech Academy of Sciences Publication Activity Database

    Burša, Milan; Kenyon, S.; Kouba, J.; Šíma, Zdislav; Vatrt, V.; Vojtíšková, M.

    -, č. 5 (2009), s. 53-63 ISSN 1801-8483 R&D Projects: GA ČR GA205/08/0328 Institutional research plan: CEZ:AV0Z10030501 Keywords : sea surface topography * satellite altimetry * vertical frames Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  13. Institutional Justification in Frames

    DEFF Research Database (Denmark)

    Baden, Christian; Schultz, Friederike

    consensus. It extents research on framing in mass communication by applying institutional theory and Boltanski and Thévenot’s (2006) theory on justification in order to explain how the success and failure of proposed interpretations depend on the mobilization of accepted social institutions to justify...

  14. Some relationship between G-frames and frames

    Directory of Open Access Journals (Sweden)

    Mehdi Rashidi-Kouchi

    2015-06-01

    Full Text Available In this paper we proved that every g-Riesz basis for Hilbert space $H$ with respect to $K$ by adding a condition is a Riesz basis for Hilbert $B(K$-module $B(H,K$. This is an extension of [A. Askarizadeh,M. A. Dehghan, {em G-frames as special frames}, Turk. J. Math., 35, (2011 1-11]. Also, we derived similar results for g-orthonormal and orthogonal bases. Some relationships between dual frame, dual g-frame and exact frame and exact g-frame are presented too.

  15. Solid-state framing camera with multiple time frames

    Energy Technology Data Exchange (ETDEWEB)

    Baker, K. L.; Stewart, R. E.; Steele, P. T.; Vernon, S. P.; Hsing, W. W.; Remington, B. A. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2013-10-07

    A high speed solid-state framing camera has been developed which can operate over a wide range of photon energies. This camera measures the two-dimensional spatial profile of the flux incident on a cadmium selenide semiconductor at multiple times. This multi-frame camera has been tested at 3.1 eV and 4.5 keV. The framing camera currently records two frames with a temporal separation between the frames of 5 ps but this separation can be varied between hundreds of femtoseconds up to nanoseconds and the number of frames can be increased by angularly multiplexing the probe beam onto the cadmium selenide semiconductor.

  16. The finite section method and problems in frame theory

    DEFF Research Database (Denmark)

    Christensen, Ole; Strohmer, T.

    2005-01-01

    solves related computational problems in frame theory. In the case of a frame which is localized w.r.t. an orthonormal basis we are able to estimate the rate of approximation. The results are applied to the reproducing kernel frame appearing in the theory for shift-invariant spaces generated by a Riesz......The finite section method is a convenient tool for approximation of the inverse of certain operators using finite-dimensional matrix techniques. In this paper we demonstrate that the method is very useful in frame theory: it leads to an efficient approximation of the inverse frame operator and also...

  17. Maximum likely scale estimation

    DEFF Research Database (Denmark)

    Loog, Marco; Pedersen, Kim Steenstrup; Markussen, Bo

    2005-01-01

    A maximum likelihood local scale estimation principle is presented. An actual implementation of the estimation principle uses second order moments of multiple measurements at a fixed location in the image. These measurements consist of Gaussian derivatives possibly taken at several scales and/or ...

  18. Robust Maximum Association Estimators

    NARCIS (Netherlands)

    A. Alfons (Andreas); C. Croux (Christophe); P. Filzmoser (Peter)

    2017-01-01

    textabstractThe maximum association between two multivariate variables X and Y is defined as the maximal value that a bivariate association measure between one-dimensional projections αX and αY can attain. Taking the Pearson correlation as projection index results in the first canonical correlation

  19. Wavelet frames and their duals

    DEFF Research Database (Denmark)

    Lemvig, Jakob

    2008-01-01

    frames with good time localization and other attractive properties. Furthermore, the dual wavelet frames are constructed in such a way that we are guaranteed that both frames will have the same desirable features. The construction procedure works for any real, expansive dilation. A quasi-affine system....... The signals are then represented by linear combinations of the building blocks with coefficients found by an associated frame, called a dual frame. A wavelet frame is a frame where the building blocks are stretched (dilated) and translated versions of a single function; such a frame is said to have wavelet...... structure. The dilation of the wavelet building blocks in higher dimension is done via a square matrix which is usually taken to be integer valued. In this thesis we step away from the "usual" integer, expansive dilation and consider more general, expansive dilations. In most applications of wavelet frames...

  20. Work and Inertial Frames

    Science.gov (United States)

    Kaufman, Richard

    2017-12-01

    A fairly recent paper resolves a large discrepancy in the internal energy utilized to fire a cannon as calculated by two inertial observers. Earth and its small reaction velocity must be considered in the system so that the change in kinetic energy is calculated correctly. This paper uses a car in a similar scenario, but considers the work done by forces acting over distances. An analysis of the system must include all energy interactions, including the work done on the car and especially the (negative) work done on Earth in a moving reference frame. This shows the importance of considering the force on Earth and the distance Earth travels. For calculation of work in inertial reference frames, the center of mass perspective is shown to be useful. We also consider the energy requirements to efficiently accelerate a mass among interacting masses.

  1. Framing Light Rail Projects

    DEFF Research Database (Denmark)

    Olesen, Mette

    2014-01-01

    In Europe, there has been a strong political will to implement light rail. This article contributes to the knowledge concerning policies around light rail by analysing how local actors frame light rail projects and which rationalities and arguments are present in this decision-making process....... The article draws on the socio-technical approach to mobilities studies in order to reassemble the decision-making process in three European cases: Bergen, Angers, and Bern. This article provides insights into the political, discursive and material production of light rail mobilities in a European context....... It identifies the planning rationales behind the systems and the policies that have been supportive of this light rail vision. Finally, the article identifies the practical challenges and potentials that have been connected to the different local frames of light rail mobility which can be used in future...

  2. Framing a Bank

    DEFF Research Database (Denmark)

    Holmgreen, Lise-Lotte

    2012-01-01

    Danish bank, Danske Bank, during the 2008 financial crisis and hence in shaping its image projected to the public. Through the study of a number of semantic frames adopted by the Danish print press and those adopted by the Bank, this article will argue for the constructions of the press putting...... considerable strain on the Bank and its image, leading it to reconsider its previous strategy of denial of responsibility...

  3. Density of Gabor Frames

    DEFF Research Database (Denmark)

    Christensen, Ole; Heil, C.; Deng, B.

    1997-01-01

    A Gabor system is a set of time-frequency shifts$S(g,\\Lambda) = \\{e^{2\\pi i b x} g(x-a)\\}_{(a,b) \\in \\Lambda}$of a function $g \\in L^2({\\bold R}^d)$.We prove that if a finite union of Gabor systems$\\bigcup_{k=1}^r S(g_k,\\Lambda_k)$, with arbitrary sequences $\\Lambda_k$,forms a frame for $L^2({\\bo...

  4. A Hubble Space Telescope Survey for Novae in M87. II. Snuffing out the Maximum Magnitude–Rate of Decline Relation for Novae as a Non-standard Candle, and a Prediction of the Existence of Ultrafast Novae

    Energy Technology Data Exchange (ETDEWEB)

    Shara, Michael M.; Doyle, Trisha; Zurek, David [Department of Astrophysics, American Museum of Natural History, Central Park West and 79th Street, New York, NY 10024-5192 (United States); Lauer, Tod R. [National Optical Astronomy Observatory, P.O. Box 26732, Tucson, AZ 85726 (United States); Baltz, Edward A. [KIPAC, SLAC, 2575 Sand Hill Road, M/S 29, Menlo Park, CA 94025 (United States); Kovetz, Attay [School of Physics and Astronomy, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv (Israel); Madrid, Juan P. [CSIRO, Astronomy and Space Science, P.O. Box 76, Epping, NSW 1710 (Australia); Mikołajewska, Joanna [N. Copernicus Astronomical Center, Polish Academy of Sciences, Bartycka 18, PL 00-716 Warsaw (Poland); Neill, J. D. [California Institute of Technology, 1200 East California Boulevard, MC 278-17, Pasadena CA 91125 (United States); Prialnik, Dina [Department of Geosciences, Tel Aviv University, Ramat Aviv, Tel Aviv 69978 (Israel); Welch, D. L. [Department of Physics and Astronomy, McMaster University, Hamilton, L8S 4M1, Ontario (Canada); Yaron, Ofer [Department of Particle Physics and Astrophysics, Weizmann Institute of Science, 76100 Rehovot (Israel)

    2017-04-20

    The extensive grid of numerical simulations of nova eruptions from the work of Yaron et al. first predicted that some classical novae might significantly deviate from the Maximum Magnitude–Rate of Decline (MMRD) relation, which purports to characterize novae as standard candles. Kasliwal et al. have announced the observational detection of a new class of faint, fast classical novae in the Andromeda galaxy. These objects deviate strongly from the MMRD relationship, as predicted by Yaron et al. Recently, Shara et al. reported the first detections of faint, fast novae in M87. These previously overlooked objects are as common in the giant elliptical galaxy M87 as they are in the giant spiral M31; they comprise about 40% of all classical nova eruptions and greatly increase the observational scatter in the MMRD relation. We use the extensive grid of the nova simulations of Yaron et al. to identify the underlying causes of the existence of faint, fast novae. These are systems that have accreted, and can thus eject, only very low-mass envelopes, of the order of 10{sup −7}–10{sup −8} M {sub ⊙}, on massive white dwarfs. Such binaries include, but are not limited to, the recurrent novae. These same models predict the existence of ultrafast novae that display decline times, t {sub 2,} to be as short as five hours. We outline a strategy for their future detection.

  5. Habitat reclamation plan to mitigate for the loss of habitat due to oil and gas production activities under maximum efficient rate, Naval Petroleum Reserve No. 1, Kern County, California

    International Nuclear Information System (INIS)

    Anderson, D.C.

    1994-11-01

    Activities associated with oil and gas development under the Maximum Efficiency Rate (MER) from 1975 to 2025 will disturb approximately 3,354 acres. Based on 1976 aerial photographs and using a dot grid methodology, the amount of land disturbed prior to MER is estimated to be 3,603 acres. Disturbances on Naval Petroleum Reserve No. 1 (NPR-1) were mapped using 1988 aerial photography and a geographical information system. A total of 6,079 acres were classified as disturbed as of June, 1988. The overall objective of this document is to provide specific information relating to the on-site habitat restoration program at NPRC. The specific objectives, which relate to the terms and conditions that must be met by DOE as a means of protecting the San Joaquin kit fox from incidental take are to: (1) determine the amount and location of disturbed lands on NPR-1 and the number of acres disturbed as a result of MER activities, (2) develop a long term (10 year) program to restore an equivalent on-site acres to that lost from prior project-related actions, and (3) examine alternative means to offset kit fox habitat loss

  6. Pseudo-set framing.

    Science.gov (United States)

    Barasz, Kate; John, Leslie K; Keenan, Elizabeth A; Norton, Michael I

    2017-10-01

    Pseudo-set framing-arbitrarily grouping items or tasks together as part of an apparent "set"-motivates people to reach perceived completion points. Pseudo-set framing changes gambling choices (Study 1), effort (Studies 2 and 3), giving behavior (Field Data and Study 4), and purchase decisions (Study 5). These effects persist in the absence of any reward, when a cost must be incurred, and after participants are explicitly informed of the arbitrariness of the set. Drawing on Gestalt psychology, we develop a conceptual account that predicts what will-and will not-act as a pseudo-set, and defines the psychological process through which these pseudo-sets affect behavior: over and above typical reference points, pseudo-set framing alters perceptions of (in)completeness, making intermediate progress seem less complete. In turn, these feelings of incompleteness motivate people to persist until the pseudo-set has been fulfilled. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Framing effects in medical situations: distinctions of attribute, goal and risky choice frames.

    Science.gov (United States)

    Peng, Jiaxi; Jiang, Yuan; Miao, Danmin; Li, Rui; Xiao, Wei

    2013-06-01

    To verify whether three different framing effects (risky choice, attribute and goal) exist in simulated medical situations and to analyse any differences. Medical decision-making problems were established, relating to medical skill evaluation, patient compliance and a selection of treatment options. All problems were described in positive and negative frame conditions. Significantly more positive evaluations were made if the doctor's medical records were described as 'of 100 patients, 70 patients became better' compared with those described as 'of 100 patients, 30 patients didn't become better'. Doctor's advice described in a negative frame resulted in significantly more decisions to comply, compared with advice described in a positive frame. Treatment options described in terms of survival rates resulted in significantly more adventurous choices compared with options described in terms of mortality rates. Decision-making reversal appeared in the risky choice and attribute frames, but not the goal frame. Framing effects were shown to exist in simulated medical situations, but there were significant differences among the three kinds of such effects.

  8. Attribute Framing and Goal Framing Effects in Health Decisions.

    Science.gov (United States)

    Krishnamurthy, Parthasarathy; Carter, Patrick; Blair, Edward

    2001-07-01

    Levin, Schneider, and Gaeth (LSG, 1998) have distinguished among three types of framing-risky choice, attribute, and goal framing-to reconcile conflicting findings in the literature. In the research reported here, we focus on attribute and goal framing. LSG propose that positive frames should be more effective than negative frames in the context of attribute framing, and negative frames should be more effective than positive frames in the context of goal framing. We test this framework by manipulating frame valence (positive vs negative) and frame type (attribute vs goal) in a unified context with common procedures. We also argue that the nature of effects in a goal-framing context may depend on the extent to which the research topic has "intrinsic self-relevance" to the population. In the context of medical decision making, we operationalize low intrinsic self-relevance by using student subjects and high intrinsic self-relevance by using patients. As expected, we find complete support for the LSG framework under low intrinsic self-relevance and modified support for the LSG framework under high intrinsic self-relevance. Overall, our research appears to confirm and extend the LSG framework. Copyright 2001 Academic Press.

  9. Framing the ultimatum game: gender differences and autonomic responses.

    Science.gov (United States)

    Sarlo, Michela; Lotto, Lorella; Palomba, Daniela; Scozzari, Simona; Rumiati, Rino

    2013-01-01

    The present study aimed at investigating whether the way offers are framed in the Ultimatum Game (UG) affects behavioral and autonomic responses in men and women. The "I give you" and "I take" expressions were used as gain and loss frames, respectively. Skin conductance and heart rate were recorded as indices of autonomic activation in response to unfair, mid-value, and fair offers. Acceptance rates were higher in men than in women under the gain frame. Moreover, men showed higher acceptance rates under the gain than under the loss frame with mid-value offers, whereas women's choices were not affected by frame. On the physiological level, men produced differential autonomic response patterns during decision-making when offers were presented under gain and loss framing. The "I take" frame, by acting as a loss frame, elicited in men the characteristic defensive response pattern that is evoked by aversive stimulation, in which increases in skin conductance are coupled with increases in heart rate. On the other hand, the "I give you" frame, by acting as a gain frame, elicited in men increases in skin conductance associated with prevailing heart rate deceleratory responses, reflecting a state of enhanced attention and orienting. In contrast, women's autonomic reactivity was not affected by frame, consistent with behavioral results. Phasic changes in heart rate were crucial in revealing differential functional significance of skin conductance responses under different frames in men, thus questioning the assumption that this autonomic measure can be used as an index of negative emotional arousal in the UG.

  10. High-speed three-frame image recording system using colored flash units and low-cost video equipment

    Science.gov (United States)

    Racca, Roberto G.; Scotten, Larry N.

    1995-05-01

    This article describes a method that allows the digital recording of sequences of three black and white images at rates of several thousand frames per second using a system consisting of an ordinary CCD camcorder, three flash units with color filters, a PC-based frame grabber board and some additional electronics. The maximum framing rate is determined by the duration of the flashtube emission, and for common photographic flash units lasting about 20 microsecond(s) it can exceed 10,000 frames per second in actual use. The subject under study is strobe- illuminated using a red, a green and a blue flash unit controlled by a special sequencer, and the three images are captured by a color CCD camera on a single video field. Color is used as the distinguishing parameter that allows the overlaid exposures to be resolved. The video output for that particular field will contain three individual scenes, one for each primary color component, which potentially can be resolved with no crosstalk between them. The output is electronically decoded into the primary color channels, frame grabbed and stored into digital memory, yielding three time-resolved images of the subject. A synchronization pulse provided by the flash sequencer triggers the frame grabbing so that the correct video field is acquired. A scheme involving the use of videotape as intermediate storage allows the frame grabbing to be performed using a monochrome video digitizer. Ideally each flash- illuminated scene would be confined to one color channel, but in practice various factors, both optical and electronic, affect color separation. Correction equations have been derived that counteract these effects in the digitized images and minimize 'ghosting' between frames. Once the appropriate coefficients have been established through a calibration procedure that needs to be performed only once for a given configuration of the equipment, the correction process is carried out transparently in software every time a

  11. Conformal frame dependence of inflation

    International Nuclear Information System (INIS)

    Domènech, Guillem; Sasaki, Misao

    2015-01-01

    Physical equivalence between different conformal frames in scalar-tensor theory of gravity is a known fact. However, assuming that matter minimally couples to the metric of a particular frame, which we call the matter Jordan frame, the matter point of view of the universe may vary from frame to frame. Thus, there is a clear distinction between gravitational sector (curvature and scalar field) and matter sector. In this paper, focusing on a simple power-law inflation model in the Einstein frame, two examples are considered; a super-inflationary and a bouncing universe Jordan frames. Then we consider a spectator curvaton minimally coupled to a Jordan frame, and compute its contribution to the curvature perturbation power spectrum. In these specific examples, we find a blue tilt at short scales for the super-inflationary case, and a blue tilt at large scales for the bouncing case

  12. MedlinePlus FAQ: Framing

    Science.gov (United States)

    ... URL of this page: https://medlineplus.gov/faq/framing.html I'd like to link to MedlinePlus, ... M. encyclopedia. Our license agreements do not permit framing of their content from our site. For more ...

  13. Conformal frame dependence of inflation

    Energy Technology Data Exchange (ETDEWEB)

    Domènech, Guillem; Sasaki, Misao, E-mail: guillem.domenech@yukawa.kyoto-u.ac.jp, E-mail: misao@yukawa.kyoto-u.ac.jp [Yukawa Institute for Theoretical Physics, Kyoto University, Kyoto 606-8502 (Japan)

    2015-04-01

    Physical equivalence between different conformal frames in scalar-tensor theory of gravity is a known fact. However, assuming that matter minimally couples to the metric of a particular frame, which we call the matter Jordan frame, the matter point of view of the universe may vary from frame to frame. Thus, there is a clear distinction between gravitational sector (curvature and scalar field) and matter sector. In this paper, focusing on a simple power-law inflation model in the Einstein frame, two examples are considered; a super-inflationary and a bouncing universe Jordan frames. Then we consider a spectator curvaton minimally coupled to a Jordan frame, and compute its contribution to the curvature perturbation power spectrum. In these specific examples, we find a blue tilt at short scales for the super-inflationary case, and a blue tilt at large scales for the bouncing case.

  14. Modelling maximum canopy conductance and transpiration in ...

    African Journals Online (AJOL)

    There is much current interest in predicting the maximum amount of water that can be transpired by Eucalyptus trees. It is possible that industrial waste water may be applied as irrigation water to eucalypts and it is important to predict the maximum transpiration rates of these plantations in an attempt to dispose of this ...

  15. Current status of and problems in ice heat storage systems contributing to improving load rate. Air conditioning system utilizing ice heat storage and building frame storage (Takenaka Corporation); Fukaritsu kaizen ni kokensuru kori chikunetsu system no genjo to kadai. Kori chikunetsu to kutai chikunetsu wo riyoshita kucho system

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Y.; Yoshitake, Y. [Takenaka Corp., Osaka (Japan)

    1998-02-01

    Development was made on a new air conditioning system, `building frame heat storage air conditioning system`, which combines an ice heat storage system with a building frame heat storage. With the building frame heat storage system, a damper is installed on an indoor device to blow cold air from the air conditioner onto slabs on the upper floor during nighttime power generating period. Heat is stored in beams, pillars and walls, and the shell absorbs and dissipates heat during daytime. Since general office buildings consume primary energy at 22.8% for heat source and 26.9% for transportation, which is greater, a natural coolant circulation type air conditioning system was developed as an air conditioning system for the secondary side. This made the building frame heat regeneration possible for the first time. With regard to heat storage quantity and heat dissipation quantity, the quantity of heat which can be stored during nighttime (10 hours) and dissipated during air conditioning using period in daytime (10 hours) is 80% of the stored heat quantity. This system was installed in a building in Kobe City. As a result of the measurement, it was found that indoor heat load reduction rate as a result of using the building frame heat storage was 24% or more in summer and 80% or more in winter. 7 figs., 2 tabs.

  16. Frames in super Hilbert modules

    Directory of Open Access Journals (Sweden)

    Mehdi Rashidi-Kouchi

    2018-01-01

    Full Text Available In this paper, we define super Hilbert module and investigate frames in this space. Super Hilbert modules are  generalization of super Hilbert spaces in Hilbert C*-module setting. Also, we define frames in a super Hilbert module and characterize them by using of the concept of g-frames in a Hilbert C*-module. Finally, disjoint frames in Hilbert C*-modules are introduced and investigated.

  17. New avenues for framing research

    NARCIS (Netherlands)

    de Vreese, C.H.

    2012-01-01

    In this article, the author reviews the studies in this special issue of the American Behavioral Scientist. It is a strong collection of articles reporting findings from an integrated project that looks at frame building, frames, and effects of frames. The project is part of an exciting large-scale

  18. Maximum entropy methods

    International Nuclear Information System (INIS)

    Ponman, T.J.

    1984-01-01

    For some years now two different expressions have been in use for maximum entropy image restoration and there has been some controversy over which one is appropriate for a given problem. Here two further entropies are presented and it is argued that there is no single correct algorithm. The properties of the four different methods are compared using simple 1D simulations with a view to showing how they can be used together to gain as much information as possible about the original object. (orig.)

  19. Freqüência cardíaca máxima em idosas brasileiras: uma comparação entre valores medidos e previstos Maximum heart rate in Brazilian elderly women: comparing measured and predicted values

    Directory of Open Access Journals (Sweden)

    Valter Abrantes Pereira da Silva

    2007-03-01

    Full Text Available OBJETIVO: O presente estudo objetivou comparar os valores de freqüência cardíaca máxima (FCmáx medidos durante um teste de esforço progressivo (TEP, com os obtidos através de equações de predição, em idosas brasileiras. MÉTODOS: Um TEP máximo sob o protocolo modificado de Bruce, realizado em esteira, foi utilizado para obtenção dos valores de referência da freqüência cardíaca máxima (FCmáx, em 93 mulheres idosas (67,1±5,16 anos. Os valores obtidos foram comparados aos estimados pelas equações "220 - idade" e a de Tanaka e cols., através da ANOVA, para amostras repetidas. A correlação e a concordância entre os valores medidos e os estimados foram testadas. Adicionalmente, a correlação entre os valores de FCmáx medidos e a idade das voluntárias foi examinada. RESULTADOS: Os resultados foram os seguintes: 1 a média da FCmáx atingida no TEP foi de 145,5±12,5 batimentos por minuto (bpm; 2 as equações "220 - idade" e a de Tanaka e cols. (2001 superestimaram significativamente (p OBJECTIVE: This study sought to compare maximum heart rate (HRmax values measured during a graded exercise test (GXT with those calculated from prediction equations in Brazilian elderly women. METHODS: A treadmill maximal graded exercise test in accordance with the modified Bruce protocol was used to obtain reference values for maximum heart rate (HRmax in 93 elderly women (mean age 67.1 ± 5.16. Measured values were compared with those estimated from the "220 - age" and Tanaka et al formulas using repeated-measures ANOVA. Correlation and agreement between measured and estimated values were tested. Also evaluated was the correlation between measured HRmax and volunteers’ age. RESULTS: Results were as follows: 1 mean HRmax reached during GXT was 145.5 ± 12,5 beats per minute (bpm; 2 both the "220 - age" and Tanaka et al (2001 equations significantly overestimated (p < 0.001 HRmax by a mean difference of 7.4 and 15.5 bpm, respectively; 3

  20. VIOLENT FRAMES IN ACTION

    Energy Technology Data Exchange (ETDEWEB)

    Sanfilippo, Antonio P.; McGrath, Liam R.; Whitney, Paul D.

    2011-11-17

    We present a computational approach to radical rhetoric that leverages the co-expression of rhetoric and action features in discourse to identify violent intent. The approach combines text mining and machine learning techniques with insights from Frame Analysis and theories that explain the emergence of violence in terms of moral disengagement, the violation of sacred values and social isolation in order to build computational models that identify messages from terrorist sources and estimate their proximity to an attack. We discuss a specific application of this approach to a body of documents from and about radical and terrorist groups in the Middle East and present the results achieved.

  1. Continuous Shearlet Tight Frames

    KAUST Repository

    Grohs, Philipp

    2010-10-22

    Based on the shearlet transform we present a general construction of continuous tight frames for L2(ℝ2) from any sufficiently smooth function with anisotropic moments. This includes for example compactly supported systems, piecewise polynomial systems, or both. From our earlier results in Grohs (Technical report, KAUST, 2009) it follows that these systems enjoy the same desirable approximation properties for directional data as the previous bandlimited and very specific constructions due to Kutyniok and Labate (Trans. Am. Math. Soc. 361:2719-2754, 2009). We also show that the representation formulas we derive are in a sense optimal for the shearlet transform. © 2010 Springer Science+Business Media, LLC.

  2. The last glacial maximum

    Science.gov (United States)

    Clark, P.U.; Dyke, A.S.; Shakun, J.D.; Carlson, A.E.; Clark, J.; Wohlfarth, B.; Mitrovica, J.X.; Hostetler, S.W.; McCabe, A.M.

    2009-01-01

    We used 5704 14C, 10Be, and 3He ages that span the interval from 10,000 to 50,000 years ago (10 to 50 ka) to constrain the timing of the Last Glacial Maximum (LGM) in terms of global ice-sheet and mountain-glacier extent. Growth of the ice sheets to their maximum positions occurred between 33.0 and 26.5 ka in response to climate forcing from decreases in northern summer insolation, tropical Pacific sea surface temperatures, and atmospheric CO2. Nearly all ice sheets were at their LGM positions from 26.5 ka to 19 to 20 ka, corresponding to minima in these forcings. The onset of Northern Hemisphere deglaciation 19 to 20 ka was induced by an increase in northern summer insolation, providing the source for an abrupt rise in sea level. The onset of deglaciation of the West Antarctic Ice Sheet occurred between 14 and 15 ka, consistent with evidence that this was the primary source for an abrupt rise in sea level ???14.5 ka.

  3. on Goal Framing

    Directory of Open Access Journals (Sweden)

    Eulàlia P. Abril

    2014-01-01

    Full Text Available En respuesta a la enorme y algunas veces conceptualmente inconsistente literatura sobre valence framing,Levin y sus colegas (1998 desarrollaron una tipología de encuadre de valencia que organiza los diferentesresultados a partir de elección arriesgada, atributo, y encuadre de los resultados (goal framing. Este estudiofavorece la literatura sobre encuadre de los resultados mediante (a su aplicación en el contexto de una cuestiónsocial como la pobreza infantil extrema; y (b el examen de los mecanismos afectivos sobre el cual el encuadrede los resultados es de eficacia persuasiva. Los resultados experimentales (N = 197 mostraron que la exposiciónal mensaje de encuadre de pérdida permitió un apoyo mayor hacia las políticas públicas que buscan erradicar lapobreza infantil, en comparación con el mensaje de encuadre de ganancia. Los resultados también revelaronque el afecto negativo sirve como herramienta mediadora de apoyo hacia las políticas públicas. Estos hallazgossugieren que, en el contexto del apoyo social hacia la población pobre, la capacidad de persuasión dentro delencuadre de pérdida se facilita cuando los participantes experimentan afectos negativos.

  4. Balinese Frame of Reference

    Directory of Open Access Journals (Sweden)

    I Nyoman Aryawibawa

    2016-04-01

    Full Text Available Abstract: Balinese Frame of Reference. Wassmann and Dasen (1998 did a study on the acquisition of Balinese frames of reference. They pointed out that, in addition to the dominant use of absolute system, the use of relative system was also observed. This article aims at verifying Wassmann and Dasen’ study. Employing monolingual Balinese speakers and using linguistic and non-linguistic tasks, Aryawibawa (2010, 2012, 2015 showed that Balinese subjects used an absolute system dominantly in responding the two tasks, e.g. The man is north/south/east/west of the car. Unlike Wassmann and Dasen’s results, no relative system was used by the subjects in solving the tasks. Instead of the relative system, an intrinsic system was also observed in this study, even though it was unfrequent. The article concludes that the absolute system was dominantly employed by Balinese speakers in describing spatial relations in Balinese. The use of the system seems to affect their cognitive functions.

  5. Cognitive framing in action.

    Science.gov (United States)

    Huhn, John M; Potts, Cory Adam; Rosenbaum, David A

    2016-06-01

    Cognitive framing effects have been widely reported in higher-level decision-making and have been ascribed to rules of thumb for quick thinking. No such demonstrations have been reported for physical action, as far as we know, but they would be expected if cognition for physical action is fundamentally similar to cognition for higher-level decision-making. To test for such effects, we asked participants to reach for a horizontally-oriented pipe to move it from one height to another while turning the pipe 180° to bring one end (the "business end") to a target on the left or right. From a physical perspective, participants could have always rotated the pipe in the same angular direction no matter which end was the business end; a given participant could have always turned the pipe clockwise or counter-clockwise. Instead, our participants turned the business end counter-clockwise for left targets and clockwise for right targets. Thus, the way the identical physical task was framed altered the way it was performed. This finding is consistent with the hypothesis that cognition for physical action is fundamentally similar to cognition for higher-level decision-making. A tantalizing possibility is that higher-level decision heuristics have roots in the control of physical action, a hypothesis that accords with embodied views of cognition. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Mapping in inertial frames

    International Nuclear Information System (INIS)

    Arunasalam, V.

    1989-05-01

    World space mapping in inertial frames is used to examine the Lorentz covariance of symmetry operations. It is found that the Galilean invariant concepts of simultaneity (S), parity (P), and time reversal symmetry (T) are not Lorentz covariant concepts for inertial observers. That is, just as the concept of simultaneity has no significance independent of the Lorentz inertial frame, likewise so are the concepts of parity and time reversal. However, the world parity (W) [i.e., the space-time reversal symmetry (P-T)] is a truly Lorentz covariant concept. Indeed, it is shown that only those mapping matrices M that commute with the Lorentz transformation matrix L (i.e., [M,L] = 0) are the ones that correspond to manifestly Lorentz covariant operations. This result is in accordance with the spirit of the world space Mach's principle. Since the Lorentz transformation is an orthogonal transformation while the Galilean transformation is not an orthogonal transformation, the formal relativistic space-time mapping theory used here does not have a corresponding non-relativistic counterpart. 12 refs

  7. Identifying issue frames in text.

    Directory of Open Access Journals (Sweden)

    Eyal Sagi

    Full Text Available Framing, the effect of context on cognitive processes, is a prominent topic of research in psychology and public opinion research. Research on framing has traditionally relied on controlled experiments and manually annotated document collections. In this paper we present a method that allows for quantifying the relative strengths of competing linguistic frames based on corpus analysis. This method requires little human intervention and can therefore be efficiently applied to large bodies of text. We demonstrate its effectiveness by tracking changes in the framing of terror over time and comparing the framing of abortion by Democrats and Republicans in the U.S.

  8. Seismic Performance of Steel Frames with Semirigid Connections

    Directory of Open Access Journals (Sweden)

    Iman Faridmehr

    2017-01-01

    Full Text Available The nonlinear stiffness matrix method was incorporated to investigate the structural performance of steel portal frames with semirigid connections. A portal frame with unstiffened extended end-plate connection was designed to demonstrate the adequacy of the proposed method. Besides, the seismic performance of steel portal frames with semirigid connections was investigated through time history analysis where kinematic hysteresis model was assigned to semirigid connections to account for energy dissipation and unloading stiffness. Based on the results of the study, it was found that generally semirigid connections influenced the force distribution which resulted in the decrease in base shear and lighter frame compared to the rigid one. The results also indicated that there was no direct relationship between maximum displacement at the top and connection stiffness in high-rise frames.

  9. Measuring the quality of a quantum reference frame: The relative entropy of frameness

    International Nuclear Information System (INIS)

    Gour, Gilad; Marvian, Iman; Spekkens, Robert W.

    2009-01-01

    In the absence of a reference frame for transformations associated with group G, any quantum state that is noninvariant under the action of G may serve as a token of the missing reference frame. We here present a measure of the quality of such a token: the relative entropy of frameness. This is defined as the relative entropy distance between the state of interest and the nearest G-invariant state. Unlike the relative entropy of entanglement, this quantity is straightforward to calculate, and we find it to be precisely equal to the G-asymmetry, a measure of frameness introduced by Vaccaro et al. It is shown to provide an upper bound on the mutual information between the group element encoded into the token and the group element that may be extracted from it by measurement. In this sense, it quantifies the extent to which the token successfully simulates a full reference frame. We also show that despite a suggestive analogy from entanglement theory, the regularized relative entropy of frameness is zero and therefore does not quantify the rate of interconversion between the token and some standard form of quantum reference frame. Finally, we show how these investigations yield an approach to bounding the relative entropy of entanglement.

  10. Maximum Entropy Fundamentals

    Directory of Open Access Journals (Sweden)

    F. Topsøe

    2001-09-01

    Full Text Available Abstract: In its modern formulation, the Maximum Entropy Principle was promoted by E.T. Jaynes, starting in the mid-fifties. The principle dictates that one should look for a distribution, consistent with available information, which maximizes the entropy. However, this principle focuses only on distributions and it appears advantageous to bring information theoretical thinking more prominently into play by also focusing on the "observer" and on coding. This view was brought forward by the second named author in the late seventies and is the view we will follow-up on here. It leads to the consideration of a certain game, the Code Length Game and, via standard game theoretical thinking, to a principle of Game Theoretical Equilibrium. This principle is more basic than the Maximum Entropy Principle in the sense that the search for one type of optimal strategies in the Code Length Game translates directly into the search for distributions with maximum entropy. In the present paper we offer a self-contained and comprehensive treatment of fundamentals of both principles mentioned, based on a study of the Code Length Game. Though new concepts and results are presented, the reading should be instructional and accessible to a rather wide audience, at least if certain mathematical details are left aside at a rst reading. The most frequently studied instance of entropy maximization pertains to the Mean Energy Model which involves a moment constraint related to a given function, here taken to represent "energy". This type of application is very well known from the literature with hundreds of applications pertaining to several different elds and will also here serve as important illustration of the theory. But our approach reaches further, especially regarding the study of continuity properties of the entropy function, and this leads to new results which allow a discussion of models with so-called entropy loss. These results have tempted us to speculate over

  11. Probable maximum flood control

    International Nuclear Information System (INIS)

    DeGabriele, C.E.; Wu, C.L.

    1991-11-01

    This study proposes preliminary design concepts to protect the waste-handling facilities and all shaft and ramp entries to the underground from the probable maximum flood (PMF) in the current design configuration for the proposed Nevada Nuclear Waste Storage Investigation (NNWSI) repository protection provisions were furnished by the United States Bureau of Reclamation (USSR) or developed from USSR data. Proposed flood protection provisions include site grading, drainage channels, and diversion dikes. Figures are provided to show these proposed flood protection provisions at each area investigated. These areas are the central surface facilities (including the waste-handling building and waste treatment building), tuff ramp portal, waste ramp portal, men-and-materials shaft, emplacement exhaust shaft, and exploratory shafts facility

  12. Introduction to maximum entropy

    International Nuclear Information System (INIS)

    Sivia, D.S.

    1988-01-01

    The maximum entropy (MaxEnt) principle has been successfully used in image reconstruction in a wide variety of fields. We review the need for such methods in data analysis and show, by use of a very simple example, why MaxEnt is to be preferred over other regularizing functions. This leads to a more general interpretation of the MaxEnt method, and its use is illustrated with several different examples. Practical difficulties with non-linear problems still remain, this being highlighted by the notorious phase problem in crystallography. We conclude with an example from neutron scattering, using data from a filter difference spectrometer to contrast MaxEnt with a conventional deconvolution. 12 refs., 8 figs., 1 tab

  13. Solar maximum observatory

    International Nuclear Information System (INIS)

    Rust, D.M.

    1984-01-01

    The successful retrieval and repair of the Solar Maximum Mission (SMM) satellite by Shuttle astronauts in April 1984 permitted continuance of solar flare observations that began in 1980. The SMM carries a soft X ray polychromator, gamma ray, UV and hard X ray imaging spectrometers, a coronagraph/polarimeter and particle counters. The data gathered thus far indicated that electrical potentials of 25 MeV develop in flares within 2 sec of onset. X ray data show that flares are composed of compressed magnetic loops that have come too close together. Other data have been taken on mass ejection, impacts of electron beams and conduction fronts with the chromosphere and changes in the solar radiant flux due to sunspots. 13 references

  14. Introduction to maximum entropy

    International Nuclear Information System (INIS)

    Sivia, D.S.

    1989-01-01

    The maximum entropy (MaxEnt) principle has been successfully used in image reconstruction in a wide variety of fields. The author reviews the need for such methods in data analysis and shows, by use of a very simple example, why MaxEnt is to be preferred over other regularizing functions. This leads to a more general interpretation of the MaxEnt method, and its use is illustrated with several different examples. Practical difficulties with non-linear problems still remain, this being highlighted by the notorious phase problem in crystallography. He concludes with an example from neutron scattering, using data from a filter difference spectrometer to contrast MaxEnt with a conventional deconvolution. 12 refs., 8 figs., 1 tab

  15. Functional Maximum Autocorrelation Factors

    DEFF Research Database (Denmark)

    Larsen, Rasmus; Nielsen, Allan Aasbjerg

    2005-01-01

    MAF outperforms the functional PCA in concentrating the interesting' spectra/shape variation in one end of the eigenvalue spectrum and allows for easier interpretation of effects. Conclusions. Functional MAF analysis is a useful methods for extracting low dimensional models of temporally or spatially......Purpose. We aim at data where samples of an underlying function are observed in a spatial or temporal layout. Examples of underlying functions are reflectance spectra and biological shapes. We apply functional models based on smoothing splines and generalize the functional PCA in......\\verb+~+\\$\\backslash\\$cite{ramsay97} to functional maximum autocorrelation factors (MAF)\\verb+~+\\$\\backslash\\$cite{switzer85,larsen2001d}. We apply the method to biological shapes as well as reflectance spectra. {\\$\\backslash\\$bf Methods}. MAF seeks linear combination of the original variables that maximize autocorrelation between...

  16. Regularized maximum correntropy machine

    KAUST Repository

    Wang, Jim Jing-Yan; Wang, Yunji; Jing, Bing-Yi; Gao, Xin

    2015-01-01

    In this paper we investigate the usage of regularized correntropy framework for learning of classifiers from noisy labels. The class label predictors learned by minimizing transitional loss functions are sensitive to the noisy and outlying labels of training samples, because the transitional loss functions are equally applied to all the samples. To solve this problem, we propose to learn the class label predictors by maximizing the correntropy between the predicted labels and the true labels of the training samples, under the regularized Maximum Correntropy Criteria (MCC) framework. Moreover, we regularize the predictor parameter to control the complexity of the predictor. The learning problem is formulated by an objective function considering the parameter regularization and MCC simultaneously. By optimizing the objective function alternately, we develop a novel predictor learning algorithm. The experiments on two challenging pattern classification tasks show that it significantly outperforms the machines with transitional loss functions.

  17. Regularized maximum correntropy machine

    KAUST Repository

    Wang, Jim Jing-Yan

    2015-02-12

    In this paper we investigate the usage of regularized correntropy framework for learning of classifiers from noisy labels. The class label predictors learned by minimizing transitional loss functions are sensitive to the noisy and outlying labels of training samples, because the transitional loss functions are equally applied to all the samples. To solve this problem, we propose to learn the class label predictors by maximizing the correntropy between the predicted labels and the true labels of the training samples, under the regularized Maximum Correntropy Criteria (MCC) framework. Moreover, we regularize the predictor parameter to control the complexity of the predictor. The learning problem is formulated by an objective function considering the parameter regularization and MCC simultaneously. By optimizing the objective function alternately, we develop a novel predictor learning algorithm. The experiments on two challenging pattern classification tasks show that it significantly outperforms the machines with transitional loss functions.

  18. Supplier-induced demand as strategic framing

    OpenAIRE

    De Jaegher, K.J.M.

    2010-01-01

    This paper develops a model of supplier-induced demand as strategic framing where the patient has reference-dependent references, and the physician can persuade the patient to buy a treatment by affecting the patient’s reference point. In the main result, the patient is assumed to have a constant rate of risk aversion (lovingness) in the gain (loss) region. Two scenarios are treated. In the cure scenario, the physician wants to frame the patient’s decision problem such that he prefers to buy ...

  19. Message framing and perinatal decisions.

    Science.gov (United States)

    Haward, Marlyse F; Murphy, Ryan O; Lorenz, John M

    2008-07-01

    The purpose of this study was to explore the effect of information framing on parental decisions about resuscitation of extremely premature infants. Secondary outcomes focused on elucidating the impact of other variables on treatment choices and determining whether those effects would take precedence over any framing effects. This confidential survey study was administered to adult volunteers via the Internet. The surveys depicted a hypothetical vignette of a threatened delivery at gestational age of 23 weeks, with prognostic outcome information framed as either survival with lack of disability (positive frame) or chance of dying and likelihood of disability among survivors (negative frame). Participants were randomly assigned to receive either the positively or negatively framed vignette. They were then asked to choose whether they would prefer resuscitation or comfort care. After completing the survey vignette, participants were directed to a questionnaire designed to test the secondary hypothesis and to explore possible factors associated with treatment decisions. A total of 146 subjects received prognostic information framed as survival data and 146 subjects received prognostic information framed as mortality data. Overall, 24% of the sample population chose comfort care and 76% chose resuscitation. A strong trend was detected toward a framing effect on treatment preference; respondents for whom prognosis was framed as survival data were more likely to elect resuscitation. This framing effect was significant in a multivariate analysis controlling for religiousness, parental status, and beliefs regarding the sanctity of life. Of these covariates, only religiousness modified susceptibility to framing; participants who were not highly religious were significantly more likely to be influenced to opt for resuscitation by the positive frame than were participants who were highly religious. Framing bias may compromise efforts to approach prenatal counseling in a

  20. High Speed Frame Synchronization and Viterbi Decoding

    DEFF Research Database (Denmark)

    Paaske, Erik; Justesen, Jørn; Larsen, Knud J.

    1996-01-01

    The purpose of Phase 1 of the study is to describe the system structure and algorithms in sufficient detail to allow drawing the high level architecture of units containing frame synchronization and Viterbi decoding. The systems we consider are high data rate space communication systems. Also...... components. Node synchronization performed within a Viterbi decoder is discussed, and algorithms for frame synchronization are described and analyzed. We present a list of system configurations that we find potentially useful. Further, the high level architecture of units that contain frame synchronization...... and various other functions needed in a complete system is presented. Two such units are described, one for placement before the Viterbi decoder and another for placement after the decoder. The high level architectures of three possible implementations of Viterbi decoders are described: The first...

  1. Dissecting the risky-choice framing effect

    Directory of Open Access Journals (Sweden)

    Ellen Peters

    2008-08-01

    Full Text Available Using five variants of the Asian Disease Problem, we dissected the risky-choice framing effect by requiring each participant to provide preference ratings for the full decision problem and also to provide attractiveness ratings for each of the component parts, i.e., the sure-thing option and the risky option. Consistent with previous research, more risky choices were made by respondents receiving negatively framed versions of the decision problems than by those receiving positively framed versions. However, different processes were evident for those scoring high and low on numeracy. Whereas the choices of the less numerate showed a large effect of frame above and beyond any influence of their evaluations of the separate options, the choices of the highly numerate were almost completely accounted for by their attractiveness ratings of the separate options. These results are consistent with an increased tendency of the highly numerate to integrate complex numeric information in the construction of their preferences and a tendency for the less numerate to respond more superficially to non-numeric sources of information.

  2. Framing the Manager

    DEFF Research Database (Denmark)

    Holmgreen, Lise-Lotte

    2013-01-01

    Genres are ways for organisations of discursively interacting with the surrounding world, with the aim of achieving specific disciplinary goals (Bhatia 2004). As such, the management job ad has the objective of finding the right candidate for the management job advertised (Norlyk 2006......). In this process, framing (Evans & Green 2006; Fillmore 1982; Kövecses 2006; Lakoff 1987, 1996) plays a salient role in conceptualising the profile and qualities of the preferred candidate, drawing on established cultural models of what constitutes the perfect leader. Thus, in a Danish setting we may talk of two...... in this realisation, the fact that one of the two models, the ‘goal-oriented motivator’ model, seems to be monopolising the genre raises a number of issues that need to be addressed: How is this model realised conceptually and linguistically? Why does this model continue to be the Danish business world’s preferred...

  3. Shield support frame. Schildausbaugestell

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, K.

    1981-09-17

    A powered shield support frame for coal sheds is described comprising of two bottom sliding shoes, a large area gob shield and a larg area roof assembly, all joined movable together. The sliding shoes and the gob shield are joined by a lemniscate guide. Two hydraulic props are arranged at the face-side at one third of the length of the sliding shoes and at the goaf-side at one third of the length of the roof assembly. A nearly horizontal lying pushing prop unit joins the bottom wall sliding shoes to the goaf-side lemniscate guide. This assembly can be applied to seams with a thickness down to 45 cm. (OGR).

  4. Voz sobre frame relay

    OpenAIRE

    D´Elia, Gabriel Anibal

    2000-01-01

    Esta tesis trata el tema de VOFR, desde la digitalización de la voz hasta su transmisión a través de dicha red, así también como la comparación con otros medios de transporte como VOIP. Dada las características del protocolo frame relay y su disponibilidad se eligió como el medio más apropiado para la transmisión de voz y datos en forma integrada sobre una misma red. El trabajo comienza con una breve explicación de la voz, su digitalización y forma actual de transmisión a través de una red di...

  5. Riesz frames and approximation of the frame coefficients

    DEFF Research Database (Denmark)

    Casazza, P.; Christensen, Ole

    1998-01-01

    A frame is a fmaily {f i } i=1 ∞ of elements in a Hilbert space with the property that every element in can be written as a (infinite) linear combination of the frame elements. Frame theory describes how one can choose the corresponding coefficients, which are called frame coefficients. From...... the mathematical point of view this is gratifying, but for applications it is a problem that the calculation requires inversion of an operator on . The projection method is introduced in order to avoid this problem. The basic idea is to consider finite subfamilies {f i } i=1 n of the frame and the orthogonal...... projection Pn onto its span. For has a representation as a linear combination of fi, i=1,2,..., n and the corresponding coefficients can be calculated using finite dimensional methods. We find conditions implying that those coefficients converge to the correct frame coefficients as n→∞, in which case we have...

  6. Behaviour of Strengthened RC Frames with Eccentric Steel Braced Frames

    Directory of Open Access Journals (Sweden)

    Kamanli Mehmet

    2017-01-01

    Full Text Available After devastating earthquakes in recent years, strengthening of reinforced concrete buildings became an important research topic. Reinforced concrete buildings can be strengthened by steel braced frames. These steel braced frames may be made of concentrically or eccentrically indicated in Turkish Earthquake Code 2007. In this study pushover analysis of the 1/3 scaled 1 reinforced concrete frame and 1/3 scaled 4 strengthened reinforced concrete frames with internal eccentric steel braced frames were conducted by SAP2000 program. According to the results of the analyses conducted, load-displacement curves of the specimens were compared and evaluated. Adding eccentric steel braces to the bare frame decreased the story drift, and significantly increased strength, stiffness and energy dissipation capacity. In this strengthening method lateral load carrying capacity, stiffness and dissipated energy of the structure can be increased.

  7. Behaviour of Strengthened RC Frames with Eccentric Steel Braced Frames

    Science.gov (United States)

    Kamanli, Mehmet; Unal, Alptug

    2017-10-01

    After devastating earthquakes in recent years, strengthening of reinforced concrete buildings became an important research topic. Reinforced concrete buildings can be strengthened by steel braced frames. These steel braced frames may be made of concentrically or eccentrically indicated in Turkish Earthquake Code 2007. In this study pushover analysis of the 1/3 scaled 1 reinforced concrete frame and 1/3 scaled 4 strengthened reinforced concrete frames with internal eccentric steel braced frames were conducted by SAP2000 program. According to the results of the analyses conducted, load-displacement curves of the specimens were compared and evaluated. Adding eccentric steel braces to the bare frame decreased the story drift, and significantly increased strength, stiffness and energy dissipation capacity. In this strengthening method lateral load carrying capacity, stiffness and dissipated energy of the structure can be increased.

  8. Difference in the craniocaudal gradient of the maximum pixel value change rate between chronic obstructive pulmonary disease patients and normal subjects using sub-mGy dynamic chest radiography with a flat panel detector system.

    Science.gov (United States)

    Yamada, Yoshitake; Ueyama, Masako; Abe, Takehiko; Araki, Tetsuro; Abe, Takayuki; Nishino, Mizuki; Jinzaki, Masahiro; Hatabu, Hiroto; Kudoh, Shoji

    2017-07-01

    To compare the craniocaudal gradients of the maximum pixel value change rate (MPCR) during tidal breathing between chronic obstructive pulmonary disease (COPD) patients and normal subjects using dynamic chest radiography. This prospective study was approved by the institutional review board and all participants provided written informed consent. Forty-three COPD patients (mean age, 71.6±8.7 years) and 47 normal subjects (non-smoker healthy volunteers) (mean age, 54.8±9.8 years) underwent sequential chest radiographs during tidal breathing in a standing position using dynamic chest radiography with a flat panel detector system. We evaluated the craniocaudal gradient of MPCR. The results were analyzed using an unpaired t-test and the Tukey-Kramer method. The craniocaudal gradients of MPCR in COPD patients were significantly lower than those in normal subjects (right inspiratory phase, 75.5±48.1 vs. 108.9±42.0s -1 cm -1 , P<0.001; right expiratory phase, 66.4±40.6 vs. 89.8±31.6s -1 cm -1 , P=0.003; left inspiratory phase, 75.5±48.2 vs. 108.2±47.2s -1 cm -1 , P=0.002; left expiratory phase, 60.9±38.2 vs. 84.3±29.5s -1 cm -1 , P=0.002). No significant differences in height, weight, or BMI were observed between COPD and normal groups. In the sub-analysis, the gradients in severe COPD patients (global initiative for chronic obstructive lung disease [GOLD] 3 or 4, n=26) were significantly lower than those in mild COPD patients (GOLD 1 or 2, n=17) for both right and left inspiratory/expiratory phases (all P≤0.005). A decrease of the craniocaudal gradient of MPCR was observed in COPD patients. The craniocaudal gradient was lower in severe COPD patients than in mild COPD patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  9. Physics of Non-Inertial Reference Frames

    International Nuclear Information System (INIS)

    Kamalov, Timur F.

    2010-01-01

    Physics of non-inertial reference frames is a generalizing of Newton's laws to any reference frames. It is the system of general axioms for classical and quantum mechanics. The first, Kinematics Principle reads: the kinematic state of a body free of forces conserves and equal in absolute value to an invariant of the observer's reference frame. The second, Dynamics Principle extended Newton's second law to non-inertial reference frames and also contains additional variables there are higher derivatives of coordinates. Dynamics Principle reads: a force induces a change in the kinematic state of the body and is proportional to the rate of its change. It is mean that if the kinematic invariant of the reference frame is n-th derivative with respect the time, then the dynamics of a body being affected by the force F is described by the 2n-th differential equation. The third, Statics Principle reads: the sum of all forces acting a body at rest is equal to zero.

  10. Solar maximum mission

    International Nuclear Information System (INIS)

    Ryan, J.

    1981-01-01

    By understanding the sun, astrophysicists hope to expand this knowledge to understanding other stars. To study the sun, NASA launched a satellite on February 14, 1980. The project is named the Solar Maximum Mission (SMM). The satellite conducted detailed observations of the sun in collaboration with other satellites and ground-based optical and radio observations until its failure 10 months into the mission. The main objective of the SMM was to investigate one aspect of solar activity: solar flares. A brief description of the flare mechanism is given. The SMM satellite was valuable in providing information on where and how a solar flare occurs. A sequence of photographs of a solar flare taken from SMM satellite shows how a solar flare develops in a particular layer of the solar atmosphere. Two flares especially suitable for detailed observations by a joint effort occurred on April 30 and May 21 of 1980. These flares and observations of the flares are discussed. Also discussed are significant discoveries made by individual experiments

  11. Counterexamples to the B-spline Conjecture for Gabor Frames

    DEFF Research Database (Denmark)

    Lemvig, Jakob; Nielsen, Kamilla Haahr

    2016-01-01

    The frame set conjecture for B-splines Bn, n≥2, states that the frame set is the maximal set that avoids the known obstructions. We show that any hyperbola of the form ab=r, where r is a rational number smaller than one and a and b denote the sampling and modulation rates, respectively, has infin...

  12. Brain potentials associated with the outcome processing in framing effects.

    Science.gov (United States)

    Ma, Qingguo; Feng, Yandong; Xu, Qing; Bian, Jun; Tang, Huixian

    2012-10-24

    Framing effect is a cognitive bias referring to the phenomenon that people respond differently to different but objectively equivalent descriptions of the same problem. By measuring event-related potentials, the present study aimed to investigate the neural mechanisms underlying the framing effect, especially how the negative and positive frames influence the outcome processing in our brain. Participants were presented directly with outcomes framed either positively in terms of lives saved or negatively in terms of lives lost in large and small group conditions, and were asked to rate the favorableness of each of them. The behavioral results showed that the framing effect occurred in both group size conditions, with more favorable evaluations associated with positive framing. Compared with outcomes in positive framing condition, a significant feedback-related negativity (FRN) effect was elicited by outcomes in negative framing condition, even though the outcomes in different conditions were objectively equivalent. The results are explained in terms of the associative model of attribute framing effect which states that attribute framing effect occurs as a result of a valence-based associative processing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Six problems in frame theory

    DEFF Research Database (Denmark)

    Christensen, Ole

    2014-01-01

    We discuss various problems in frame theory that have been open for some years. A short discussion of frame theory is also provided, but it only contains the information that is necessary in order to understand the open problems and their role.......We discuss various problems in frame theory that have been open for some years. A short discussion of frame theory is also provided, but it only contains the information that is necessary in order to understand the open problems and their role....

  14. Pairs of dual periodic frames

    DEFF Research Database (Denmark)

    Christensen, Ole; Goh, Say Song

    2012-01-01

    The time–frequency analysis of a signal is often performed via a series expansion arising from well-localized building blocks. Typically, the building blocks are based on frames having either Gabor or wavelet structure. In order to calculate the coefficients in the series expansion, a dual frame...... is needed. The purpose of the present paper is to provide constructions of dual pairs of frames in the setting of the Hilbert space of periodic functions L2(0,2π). The frames constructed are given explicitly as trigonometric polynomials, which allows for an efficient calculation of the coefficients...

  15. Frames, agency and institutional change

    DEFF Research Database (Denmark)

    Rasmussen, Grane Mikael Gregaard; Jensen, Per Langaa; Gottlieb, Stefan Christoffer

    2017-01-01

    This study examines change and the sources influencing the formulation and diffusion of policies in construction. The change examined is the introduction of a benchmarking policy initiative in the Danish construction industry. Using institutional theory with emphasis on the concepts of frames...... and framings, we show how strategically motivated actors are able to frame policy problems in ways that disclose the mixture of motives, interests and institutional mechanisms at play in change processes. In doing so, we contribute to the literature on the role of agency in institutional change and the framing...

  16. column frame for design of reinforced concrete sway frames

    African Journals Online (AJOL)

    adminstrator

    design of slender reinforced concrete columns in sway frames according .... concrete,. Ac = gross cross-sectional area of the columns. Step 3: Effective Buckling Length Factors. The effective buckling length factors of columns in a sway frame shall be computed by .... shall have adequate resistance to failure in a sway mode ...

  17. Power to the frame: bringing sociology back to frame analysis

    NARCIS (Netherlands)

    Vliegenthart, R.; van Zoonen, L.

    2011-01-01

    This article critically reviews current frame and framing research in media and communication studies. It is first argued that most authors fail to distinguish between ‘frame’ and ‘framing’ and therewith produce a conceptual confusion and imprecision that is not conducive to the field. Second, it is

  18. Value Framing: A Prelude to Software Problem Framing

    NARCIS (Netherlands)

    Wieringa, Roelf J.; Gordijn, Jaap; van Eck, Pascal; Cox, K.; Hall, J.G.; Rapanotti, L.

    2004-01-01

    Software problem framing is a way to find specifications for software. Software problem frames can be used to structure the environment of a software system (the machine) and specify desired software properties in such a way that we can show that software with these properties will help achieve the

  19. New characterizations of fusion frames (frames of subspaces)

    Indian Academy of Sciences (India)

    Theory (College Park, MD, 2003) Contemp. Math. 345, Amer. Math. Soc. (RI: Provi- dence) (2004) 87–113. [4] Casazza P G and Kutyniok G, Robustness of Fusion Frames under Erasures of sub- spaces and of Local Frame Vectors, Radon transforms, geometry, and wavelets (LA: New Orleans) (2006) Contemp. Math., Amer.

  20. Body frames and frame singularities for three-atom systems

    International Nuclear Information System (INIS)

    Littlejohn, R.G.; Mitchell, K.A.; Aquilanti, V.; Cavalli, S.

    1998-01-01

    The subject of body frames and their singularities for three-particle systems is important not only for large-amplitude rovibrational coupling in molecular spectroscopy, but also for reactive scattering calculations. This paper presents a geometrical analysis of the meaning of body frame conventions and their singularities in three-particle systems. Special attention is devoted to the principal axis frame, a certain version of the Eckart frame, and the topological inevitability of frame singularities. The emphasis is on a geometrical picture, which is intended as a preliminary study for the more difficult case of four-particle systems, where one must work in higher-dimensional spaces. The analysis makes extensive use of kinematic rotations. copyright 1998 The American Physical Society

  1. Riesz Frames and Approximation of the Frame Coefficients

    DEFF Research Database (Denmark)

    Christensen, Ole

    1996-01-01

    A frame is a familyof elements in a Hilbert space with the propertythat every element in the Hilbert space can be written as a (infinite)linear combination of the frame elements. Frame theory describes howone can choose the corresponding coefficients, which are calledframe coefficients. From...... the mathematical point of view this isgratifying, but for applications it is a problem that the calculationrequires inversion of an operator on the Hilbert space.The projection method is introduced in order to avoid this problem.The basic idea is to consider finite subfamiliesof the frame and the orthogonal...... projection onto its span. Forfin QTR H,P_nf has a representation as a linear combinationof f_i,i=1,2,..,n, and the corresponding coefficients can be calculatedusing finite dimensional methods. We find conditions implying that thosecoefficients converge to the correct frame coefficients as n goes...

  2. Framing the frame: How task goals determine the likelihood and direction of framing effects

    OpenAIRE

    Todd McElroy; John J. Seta

    2007-01-01

    We examined how the goal of a decision task influences the perceived positive, negative valence of the alternatives and thereby the likelihood and direction of framing effects. In Study 1 we manipulated the goal to increase, decrease or maintain the commodity in question and found that when the goal of the task was to increase the commodity, a framing effect consistent with those typically observed in the literature was found. When the goal was to decrease, a framing effect opposite to the ty...

  3. Notifiable events in systems for fission of nuclear fuels - nuclear power plants and research reactors with maximum output exceeding 50 kW of thermal normal rating - in the Federal Republic of Germany. Quarterly report, 2nd quarter of 1996

    International Nuclear Information System (INIS)

    1996-01-01

    There were 32 notifiable events in nuclear power plants in Germany in the second quarter of 1996. The report lists and characterises all the 32 events notified in the reporting period. The events did not involve any radioactivity release exceeding the maximum permissible limits during this period, so that there were no radiation hazards to the population or the environment. One event was classified at level 1 of the INES event scale (Anomaly). Research reactor operators in Germany reported 5 notifiable events in the reporting period. The report lists and characterises these events. These events did not involve any radioactivity release exceeding the maximum permissible limits during this period, so that there were no radiation hazards to the population or the environment. All events notified were classified into the lowest categories of safety significance of the official event scales (N, or below scale). (orig./DG) [de

  4. [The framing effect: medical implications].

    Science.gov (United States)

    Mazzocco, Ketti; Cherubini, Paolo; Rumiati, Rino

    2005-01-01

    Over the last 20 years, many studies explored how the way information is presented modifies choices. This sort of effect, referred to as "framing effects", typically consists of the inversion of choices when presenting structurally identical decision problems in different ways. It is a common assumption that physicians are unaffected (or less affected) by the surface description of a decision problem, because they are formally trained in medical decision making. However, several studies showed that framing effects occur even in the medical field. The complexity and variability of these effects are remarkable, making it necessary to distinguish among different framing effects, depending on whether the effect is obtained by modifying adjectives (attribute framing), goals of a behavior (goal framing), or the probability of an outcome (risky choice framing). A further reason for the high variability of the framing effects seems to be the domain of the decision problem, with different effects occurring in prevention decisions, disease-detection decisions, and treatment decisions. The present work reviews the studies on framing effects, in order to summarize them and clarify their possible role in medical decision making.

  5. FRAME CATAGORIZATION OF CONVERSATIONAL INTIMACY

    OpenAIRE

    Lyubov Kit

    2017-01-01

    The article deals with the notion of intimacy. The frame of intimacy is studied on the basis of the linguistic parameters, analysis of text extracts and universal knowledge about intimacy. Frame analysis helped to establish the catagorization of types and nominators of intimate speech genres, their construction in static and dynamic aspects.

  6. Frame Catagorization of Conversational Intimacy

    OpenAIRE

    Lyubov Kit

    2017-01-01

    The article deals with the notion of intimacy. The frame of intimacy is studied on the basis of the linguistic parameters, analysis of text extracts and universal knowledge about intimacy. Frame analysis helped to establish the catagorization of types and nominators of intimate speech genres, their construction in static and dynamic aspects.

  7. Frames and outer frames for Hilbert C^*-modules

    OpenAIRE

    Arambašić, Ljiljana; Bakić, Damir

    2015-01-01

    The goal of the present paper is to extend the theory of frames for countably generated Hilbert $C^*$-modules over arbitrary $C^*$-algebras. In investigating the non-unital case we introduce the concept of outer frame as a sequence in the multiplier module $M(X)$ that has the standard frame property when applied to elements of the ambient module $X$. Given a Hilbert $\\A$-module $X$, we prove that there is a bijective correspondence of the set of all adjointable surjections from the generalize...

  8. Talking frames : the assessment, use, and impact of message frames in conversational perspective

    NARCIS (Netherlands)

    Buiten, van M.

    2007-01-01

    Choice behavior is susceptible to slight changes in the representation and formulation of messages (e.g., Tversky & Kahneman, 1981), thus violating the normative requirement of "description invariance". Even logically equivalent message frames (e.g., "80% success rate of a new product launch" vs.

  9. Geodesic acoustic eigenmode for tokamak equilibrium with maximum of local GAM frequency

    Energy Technology Data Exchange (ETDEWEB)

    Lakhin, V.P. [NRC “Kurchatov Institute”, Moscow (Russian Federation); Sorokina, E.A., E-mail: sorokina.ekaterina@gmail.com [NRC “Kurchatov Institute”, Moscow (Russian Federation); Peoples' Friendship University of Russia, Moscow (Russian Federation)

    2014-01-24

    The geodesic acoustic eigenmode for tokamak equilibrium with the maximum of local GAM frequency is found analytically in the frame of MHD model. The analysis is based on the asymptotic matching technique.

  10. Analysis of frame structure of medium and small truck crane

    Science.gov (United States)

    Cao, Fuyi; Li, Jinlong; Cui, Mengkai

    2018-03-01

    Truck crane is an important part of hoisting machinery. Frame, as the support component of the quality of truck crane, determines the safety of crane jib load and the rationality of structural design. In this paper, the truck crane frame is a box structure, the three-dimensional model is established in CATIA software, and imported into Hyperworks software for finite element analysis. On the base of doing constraints and loads for the finite element model of the frame, the finite element static analysis is carried out. And the static stress test verifies whether the finite element model and the frame structure design are reasonable; then the free modal analysis of the frame and the analysis of the first 8 - order modal vibration deformation are carried out. The analysis results show that the maximum stress value of the frame is greater than the yield limit value of the material, and the low-order modal value is close to the excitation frequency value, which needs to be improved to provide theoretical reference for the structural design of the truck crane frame.

  11. Autist mobile seat's frame strength simulation used in a car

    Science.gov (United States)

    Suryo, S. H.; Jamari, J.; Naufal, G. K.; Ismail, R.; Bayuseno, A. P.; Desiningrum, D. R.

    2016-04-01

    Going on a car with autistic children needs a special handling. Autistic children that tend to be hyperactive in the car may disturb driving. A tool is needed to keep them in a calm state when they are in the car. Autist Mobile Seat is an aid for the autistic children when going on a car. The aid is an additional seat paired with the main seat of the car. This aid consists of three main things: Main frame, body skin, and pneumatic system. Frame as the main component supporting the Autist Mobile Seat functions as a holder as well as a body skin retainer in order to be able to retain the body of the autistic children. The strength of the frame from this Autist Mobile Seat should be counted as an anticipation from the failure of the frame function when receiving load when used by the autistic children in the car. Consequently, a test on the frame of the Autist Mobile Seat towards the load received should be conducted by using a method of FEM (Finite Element Method) with the help of commercial software. The simulation produces the maximum strength, the frame towards the load received as well as the critical point on the frame when loading occurs.

  12. FRAMING EFFECTS ON PHYSICIANS' JUDGMENT AND DECISION MAKING.

    Science.gov (United States)

    Bui, Thanh C; Krieger, Heather A; Blumenthal-Barby, Jennifer S

    2015-10-01

    This study aimed to assess physicians' susceptibility to framing effects in clinical judgment and decision making. A survey was administered online to 159 general internists in the United States. Participants were randomized into two groups, in which clinical scenarios varied in their framings: frequency vs percentage, with cost information vs without, female patient vs male patient, and mortality vs survival. Results showed that physicians' recommendations for patients in hypothetical scenarios were significantly different when the predicted probability of the outcomes was presented in frequency versus percentage form and when it was presented in mortality rate vs survival rate of the same magnitude. Physicians' recommendations were not different for other framing effects.

  13. Framed School--Frame Factors, Frames and the Dynamics of Social Interaction in School

    Science.gov (United States)

    Persson, Anders

    2015-01-01

    This paper aims to show how the Goffman frame perspective can be used in an analysis of school and education and how it can be combined, in such analysis, with the frame factor perspective. The latter emphasizes factors that are determined outside the teaching process, while the former stresses how actors organize their experiences and define…

  14. serialising languages: satellite-framed, verb-framed or neither

    African Journals Online (AJOL)

    George Saad

    Figure 2: Verb-framed construction type (Slobin 2000: 109). 2 ... 2 An anonymous reviewer asks why we have replaced Talmy's conflation term “Ground” with ..... an S-language may predispose speakers to pay more linguistic attention to.

  15. Serialising languages: Satellite-framed, verb-framed or neither ...

    African Journals Online (AJOL)

    The diversity in the coding of the core schema of motion, i.e., Path, has led to a traditional typology of languages into verb-framed and satellite-framed languages. In the former Path is encoded in verbs and in the latter it is encoded in non-verb elements that function as sisters to co-event expressing verbs such as manner ...

  16. Framing of health information messages.

    Science.gov (United States)

    Akl, Elie A; Oxman, Andrew D; Herrin, Jeph; Vist, Gunn E; Terrenato, Irene; Sperati, Francesca; Costiniuk, Cecilia; Blank, Diana; Schünemann, Holger

    2011-12-07

    The same information about the evidence on health effects can be framed either in positive words or in negative words. Some research suggests that positive versus negative framing can lead to different decisions, a phenomenon described as the framing effect. Attribute framing is the positive versus negative description of a specific attribute of a single item or a state, for example, "the chance of survival with cancer is 2/3" versus "the chance of mortality with cancer is 1/3". Goal framing is the description of the consequences of performing or not performing an act as a gain versus a loss, for example, "if you undergo a screening test for cancer, your survival will be prolonged" versus "if you don't undergo screening test for cancer, your survival will be shortened". To evaluate the effects of attribute (positive versus negative) framing and of goal (gain versus loss) framing of the same health information, on understanding, perception of effectiveness, persuasiveness, and behavior of health professionals, policy makers, and consumers. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, issue 3 2007), MEDLINE (Ovid) (1966 to October 2007), EMBASE (Ovid) (1980 to October 2007), PsycINFO (Ovid) (1887 to October 2007). There were no language restrictions. We reviewed the reference lists of related systematic reviews, included studies and of excluded but closely related studies. We also contacted experts in the field. We included randomized controlled trials, quasi-randomised controlled trials, and cross-over studies with health professionals, policy makers, and consumers evaluating one of the two types of framing. Two review authors extracted data in duplicate and independently. We graded the quality of evidence for each outcome using the GRADE approach. We standardized the outcome effects using standardized mean difference (SMD). We stratified the analysis by the type of framing (attribute, goal) and conducted pre

  17. Frames and counter-frames giving meaning to dementia: a framing analysis of media content.

    Science.gov (United States)

    Van Gorp, Baldwin; Vercruysse, Tom

    2012-04-01

    Media tend to reinforce the stigmatization of dementia as one of the most dreaded diseases in western society, which may have repercussions on the quality of life of those with the illness. The persons with dementia, but also those around them become imbued with the idea that life comes to an end as soon as the diagnosis is pronounced. The aim of this paper is to understand the dominant images related to dementia by means of an inductive framing analysis. The sample is composed of newspaper articles from six Belgian newspapers (2008-2010) and a convenience sample of popular images of the condition in movies, documentaries, literature and health care communications. The results demonstrate that the most dominant frame postulates that a human being is composed of two distinct parts: a material body and an immaterial mind. If this frame is used, the person with dementia ends up with no identity, which is in opposition to the Western ideals of personal self-fulfilment and individualism. For each dominant frame an alternative counter-frame is defined. It is concluded that the relative absence of counter-frames confirms the negative image of dementia. The inventory might be a help for caregivers and other professionals who want to evaluate their communication strategy. It is discussed that a more resolute use of counter-frames in communication about dementia might mitigate the stigma that surrounds dementia. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Putting Safety in the Frame

    Directory of Open Access Journals (Sweden)

    Valerie Jean O’Keeffe

    2015-06-01

    Full Text Available Current patient safety policy focuses nursing on patient care goals, often overriding nurses’ safety. Without understanding how nurses construct work health and safety (WHS, patient and nurse safety cannot be reconciled. Using ethnography, we examine social contexts of safety, studying 72 nurses across five Australian hospitals making decisions during patient encounters. In enacting safe practice, nurses used “frames” built from their contextual experiences to guide their behavior. Frames are produced by nurses, and they structure how nurses make sense of their work. Using thematic analysis, we identify four frames that inform nurses’ decisions about WHS: (a communicating builds knowledge, (b experiencing situations guides decisions, (c adapting procedures streamlines work, and (d team working promotes safe working. Nurses’ frames question current policy and practice by challenging how nurses’ safety is positioned relative to patient safety. Recognizing these frames can assist the design and implementation of effective WHS management.

  19. 22 CFR 201.67 - Maximum freight charges.

    Science.gov (United States)

    2010-04-01

    ..., commodity rate classification, quantity, vessel flag category (U.S.-or foreign-flag), choice of ports, and... the United States. (2) Maximum charter rates. (i) USAID will not finance ocean freight under any... owner(s). (4) Maximum liner rates. USAID will not finance ocean freight for a cargo liner shipment at a...

  20. Credal Networks under Maximum Entropy

    OpenAIRE

    Lukasiewicz, Thomas

    2013-01-01

    We apply the principle of maximum entropy to select a unique joint probability distribution from the set of all joint probability distributions specified by a credal network. In detail, we start by showing that the unique joint distribution of a Bayesian tree coincides with the maximum entropy model of its conditional distributions. This result, however, does not hold anymore for general Bayesian networks. We thus present a new kind of maximum entropy models, which are computed sequentially. ...

  1. The hot hand belief and framing effects.

    Science.gov (United States)

    MacMahon, Clare; Köppen, Jörn; Raab, Markus

    2014-09-01

    Recent evidence of the hot hand in sport-where success breeds success in a positive recency of successful shots, for instance-indicates that this pattern does not actually exist. Yet the belief persists. We used 2 studies to explore the effects of framing on the hot hand belief in sport. We looked at the effect of sport experience and task on the perception of baseball pitch behavior as well as the hot hand belief and free-throw behavior in basketball. Study 1 asked participants to designate outcomes with different alternation rates as the result of baseball pitches or coin tosses. Study 2 examined basketball free-throw behavior and measured predicted success before each shot as well as general belief in the hot hand pattern. The results of Study 1 illustrate that experience and stimulus alternation rates influence the perception of chance in human performance tasks. Study 2 shows that physically performing an act and making judgments are related. Specifically, beliefs were related to overall performance, with more successful shooters showing greater belief in the hot hand and greater predicted success for upcoming shots. Both of these studies highlight that the hot hand belief is influenced by framing, which leads to instability and situational contingencies. We show the specific effects of framing using accumulated experience of the individual with the sport and knowledge of its structure and specific experience with sport actions (basketball shots) prior to judgments.

  2. Optimization of a space spectrograph main frame and frequency response analysis of the frame

    Science.gov (United States)

    Zhang, Xin-yu; Chen, Zhi-yuan; Yang, Shi-mo

    2009-07-01

    A space spectrograph main structure is optimized and examined in order to satisfy the space operational needs. The space spectrograph will be transported into its operational orbit by the launch vehicle and it will undergo dynamic environment in the spacecraft injection period. The unexpected shocks may cause declination of observation accuracy and even equipment damages. The main frame is one of the most important parts because its mechanical performance has great influence on the operational life of the spectrograph, accuracy of observation, etc. For the reason of cost reduction and stability confirming, lower weight and higher structure stiffness of the frame are simultaneously required. Structure optimization was conducted considering the initial design modal analysis results. The base modal frequency raised 10.34% while the whole weight lowered 8.63% compared to the initial design. The purpose of this study is to analyze the new design of main frame mechanical properties and verify whether it can satisfy strict optical demands under the dynamic impact during spacecraft injection. For realizing and forecasting the frequency response characteristics of the main structure in mechanical environment experiment, dynamic analysis of the structure should be performed simulating impulse loads from the bottom base. Therefore, frequency response analysis (FRA) of the frame was then performed using the FEA software MSC.PATRAN/NASTRAN. Results of shock response spectrum (SRS) responses from the base excitations were given. Stress and acceleration dynamic responses of essential positions in the spacecraft injection course were also calculated and spectrometer structure design was examined considering stiffness / strength demands. In this simulation, maximum stresses of Cesic material in two acceleration application cases are 45.1 and 74.1 MPa, respectively. They are all less than yield strengths. As is demonstrated from the simulation, strength reservation of the frame is

  3. Motion compensated frame interpolation with a symmetric optical flow constraint

    DEFF Research Database (Denmark)

    Rakêt, Lars Lau; Roholm, Lars; Bruhn, Andrés

    2012-01-01

    We consider the problem of interpolating frames in an image sequence. For this purpose accurate motion estimation can be very helpful. We propose to move the motion estimation from the surrounding frames directly to the unknown frame by parametrizing the optical flow objective function such that ......We consider the problem of interpolating frames in an image sequence. For this purpose accurate motion estimation can be very helpful. We propose to move the motion estimation from the surrounding frames directly to the unknown frame by parametrizing the optical flow objective function...... methods. The proposed reparametrization is generic and can be applied to almost every existing algorithm. In this paper we illustrate its advantages by considering the classic TV-L1 optical flow algorithm as a prototype. We demonstrate that this widely used method can produce results that are competitive...... with current state-of-the-art methods. Finally we show that the scheme can be implemented on graphics hardware such that it be- comes possible to double the frame rate of 640 × 480 video footage at 30 fps, i.e. to perform frame doubling in realtime....

  4. A novel simultaneous streak and framing camera without principle errors

    Science.gov (United States)

    Jingzhen, L.; Fengshan, S.; Ningwen, L.; Xiangdong, G.; Bin, H.; Qingyang, W.; Hongyi, C.; Yi, C.; Xiaowei, L.

    2018-02-01

    A novel simultaneous streak and framing camera with continuous access, the perfect information of which is far more important for the exact interpretation and precise evaluation of many detonation events and shockwave phenomena, has been developed. The camera with the maximum imaging frequency of 2 × 106 fps and the maximum scanning velocity of 16.3 mm/μs has fine imaging properties which are the eigen resolution of over 40 lp/mm in the temporal direction and over 60 lp/mm in the spatial direction and the framing frequency principle error of zero for framing record, and the maximum time resolving power of 8 ns and the scanning velocity nonuniformity of 0.136%~-0.277% for streak record. The test data have verified the performance of the camera quantitatively. This camera, simultaneously gained frames and streak with parallax-free and identical time base, is characterized by the plane optical system at oblique incidence different from space system, the innovative camera obscura without principle errors, and the high velocity motor driven beryllium-like rotating mirror, made of high strength aluminum alloy with cellular lateral structure. Experiments demonstrate that the camera is very useful and reliable to take high quality pictures of the detonation events.

  5. Stereotactic biopsy of cerebellar lesions: straight versus oblique frame positioning.

    Science.gov (United States)

    Quick-Weller, Johanna; Brawanski, Nina; Dinc, Nazife; Behmanesh, Bedjahn; Kammerer, Sara; Dubinski, Daniel; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-10-26

    Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.

  6. Reynolds Stress Closure for Inertial Frames and Rotating Frames

    Science.gov (United States)

    Petty, Charles; Benard, Andre

    2017-11-01

    In a rotating frame-of-reference, the Coriolis acceleration and the mean vorticity field have a profound impact on the redistribution of kinetic energy among the three components of the fluctuating velocity. Consequently, the normalized Reynolds (NR) stress is not objective. Furthermore, because the Reynolds stress is defined as an ensemble average of a product of fluctuating velocity vector fields, its eigenvalues must be non-negative for all turbulent flows. These fundamental properties (realizability and non-objectivity) of the NR-stress cannot be compromised in computational fluid dynamic (CFD) simulations of turbulent flows in either inertial frames or in rotating frames. The recently developed universal realizable anisotropic prestress (URAPS) closure for the NR-stress depends explicitly on the local mean velocity gradient and the Coriolis operator. The URAPS-closure is a significant paradigm shift from turbulent closure models that assume that dyadic-valued operators associated with turbulent fluctuations are objective.

  7. The Temptation of Zero Price: Event-Related Potentials Evidence of How Price Framing Influences the Purchase of Bundles.

    Science.gov (United States)

    Ma, Haiying; Mo, Zan; Zhang, Huijun; Wang, Cuicui; Fu, Huijian

    2018-01-01

    Studies have revealed that consumers are susceptible to price framing effect, a common cognitive bias, due to their limited capacity in processing information. The effect of price framing in a bundling context and its neural correlates, however, remain not clearly characterized. The present study applied the event-related potentials (ERPs) approach to investigate the role of price framing in information processing and purchase decision making in a bundling context. Three price frames were created with practically identical total prices (with a maximum difference of ¥0.1, which was about equal to 0.016 US dollars) for a bundle with two components, a focal product and a tie-in product. In normal price condition (NP), both the focal and tie-in products were offered at a normal discounted price; in zero price condition (ZP), the tie-in product was offered free while the total price of the bundle remained the same as NP; whereas in low price condition (LP), the tie-in product was offered at a low token price (¥0.1), and the focal product shared the same price as the focal product of ZP. The behavioral results showed a higher purchase rate and a shorter reaction time for ZP in contrast to NP. Neurophysiologically, enlarged LPP amplitude was elicited by ZP relative to NP, suggesting that ZP triggered a stronger positive affect that could motivate decision to buy. Thus, this study provides both behavioral and neural evidence for how different price framing information is processed and ultimately gives rise to price framing effect in purchase decision making.

  8. The Temptation of Zero Price: Event-Related Potentials Evidence of How Price Framing Influences the Purchase of Bundles

    Science.gov (United States)

    Ma, Haiying; Mo, Zan; Zhang, Huijun; Wang, Cuicui; Fu, Huijian

    2018-01-01

    Studies have revealed that consumers are susceptible to price framing effect, a common cognitive bias, due to their limited capacity in processing information. The effect of price framing in a bundling context and its neural correlates, however, remain not clearly characterized. The present study applied the event-related potentials (ERPs) approach to investigate the role of price framing in information processing and purchase decision making in a bundling context. Three price frames were created with practically identical total prices (with a maximum difference of ¥0.1, which was about equal to 0.016 US dollars) for a bundle with two components, a focal product and a tie-in product. In normal price condition (NP), both the focal and tie-in products were offered at a normal discounted price; in zero price condition (ZP), the tie-in product was offered free while the total price of the bundle remained the same as NP; whereas in low price condition (LP), the tie-in product was offered at a low token price (¥0.1), and the focal product shared the same price as the focal product of ZP. The behavioral results showed a higher purchase rate and a shorter reaction time for ZP in contrast to NP. Neurophysiologically, enlarged LPP amplitude was elicited by ZP relative to NP, suggesting that ZP triggered a stronger positive affect that could motivate decision to buy. Thus, this study provides both behavioral and neural evidence for how different price framing information is processed and ultimately gives rise to price framing effect in purchase decision making. PMID:29731705

  9. The Temptation of Zero Price: Event-Related Potentials Evidence of How Price Framing Influences the Purchase of Bundles

    Directory of Open Access Journals (Sweden)

    Haiying Ma

    2018-04-01

    Full Text Available Studies have revealed that consumers are susceptible to price framing effect, a common cognitive bias, due to their limited capacity in processing information. The effect of price framing in a bundling context and its neural correlates, however, remain not clearly characterized. The present study applied the event-related potentials (ERPs approach to investigate the role of price framing in information processing and purchase decision making in a bundling context. Three price frames were created with practically identical total prices (with a maximum difference of ¥0.1, which was about equal to 0.016 US dollars for a bundle with two components, a focal product and a tie-in product. In normal price condition (NP, both the focal and tie-in products were offered at a normal discounted price; in zero price condition (ZP, the tie-in product was offered free while the total price of the bundle remained the same as NP; whereas in low price condition (LP, the tie-in product was offered at a low token price (¥0.1, and the focal product shared the same price as the focal product of ZP. The behavioral results showed a higher purchase rate and a shorter reaction time for ZP in contrast to NP. Neurophysiologically, enlarged LPP amplitude was elicited by ZP relative to NP, suggesting that ZP triggered a stronger positive affect that could motivate decision to buy. Thus, this study provides both behavioral and neural evidence for how different price framing information is processed and ultimately gives rise to price framing effect in purchase decision making.

  10. Evaluating the maximum patient radiation dose in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, M.; Chida, K.; Sato, T.; Oosaka, H.; Tosa, T.; Kadowaki, K.

    2011-01-01

    Many of the X-ray systems that are used for cardiac interventional radiology provide no way to evaluate the patient maximum skin dose (MSD). The authors report a new method for evaluating the MSD by using the cumulative patient entrance skin dose (ESD), which includes a back-scatter factor and the number of cine-angiography frames during percutaneous coronary intervention (PCI). Four hundred consecutive PCI patients (315 men and 85 women) were studied. The correlation between the cumulative ESD and number of cine-angiography frames was investigated. The irradiation and overlapping fields were verified using dose-mapping software. A good correlation was found between the cumulative ESD and the number of cine-angiography frames. The MSD could be estimated using the proportion of cine-angiography frames used for the main angle of view relative to the total number of cine-angiography frames and multiplying this by the cumulative ESD. The average MSD (3.0±1.9 Gy) was lower than the average cumulative ESD (4.6±2.6 Gy). This method is an easy way to estimate the MSD during PCI. (authors)

  11. Sporadic frame dropping impact on quality perception

    Science.gov (United States)

    Pastrana-Vidal, Ricardo R.; Gicquel, Jean Charles; Colomes, Catherine; Cherifi, Hocine

    2004-06-01

    Over the past few years there has been an increasing interest in real time video services over packet networks. When considering quality, it is essential to quantify user perception of the received sequence. Severe motion discontinuities are one of the most common degradations in video streaming. The end-user perceives a jerky motion when the discontinuities are uniformly distributed over time and an instantaneous fluidity break is perceived when the motion loss is isolated or irregularly distributed. Bit rate adaptation techniques, transmission errors in the packet networks or restitution strategy could be the origin of this perceived jerkiness. In this paper we present a psychovisual experiment performed to quantify the effect of sporadically dropped pictures on the overall perceived quality. First, the perceptual detection thresholds of generated temporal discontinuities were measured. Then, the quality function was estimated in relation to a single frame dropping for different durations. Finally, a set of tests was performed to quantify the effect of several impairments distributed over time. We have found that the detection thresholds are content, duration and motion dependent. The assessment results show how quality is impaired by a single burst of dropped frames in a 10 sec sequence. The effect of several bursts of discarded frames, irregularly distributed over the time is also discussed.

  12. Frames of exponentials:lower frame bounds for finite subfamilies, and approximation of the inverse frame operator

    DEFF Research Database (Denmark)

    Christensen, Ole; Lindner, Alexander M

    2001-01-01

    We give lower frame bounds for finite subfamilies of a frame of exponentials {e(i lambdak(.))}k is an element ofZ in L-2(-pi,pi). We also present a method for approximation of the inverse frame operator corresponding to {e(i lambdak(.))}k is an element ofZ, where knowledge of the frame bounds for...

  13. C-connected frame congruences

    Directory of Open Access Journals (Sweden)

    Dharmanand Baboolal

    2017-01-01

    Full Text Available We discuss the congruences $theta$ that are connected as  elements of the (totally disconnected congruence frame $CF L$,  and show that they are in a one-to-one correspondence with the completely prime elements of $L$, giving an explicit formula. Then we investigate those frames $L$ with enough connected congruences to cover the whole of $CF L$. They are, among others, shown to be $T_D$-spatial;  characteristics for some special cases (Boolean, linear, scattered and Noetherian are presented.

  14. Dynamics of entanglement under decoherence in noninertial frames

    International Nuclear Information System (INIS)

    Shi Jia-Dong; Wu Tao; Song Xue-Ke; Ye Liu

    2014-01-01

    In this paper, we investigate the entanglement dynamics of a two-qubit entangled state coupled with its noisy environment, and plan to utilize weak measurement and quantum reversal measurement to study the entanglement dynamics under different decoherence channels in noninertial frames. Through the calculations and analyses, it is shown that the weak measurement can prevent entanglement from coupling to the amplitude damping channel, while the system is under the phase damping and flip channels. This protection protocol cannot prevent entanglement but will accelerate the death of entanglement. In addition, if the system is in the noninertial reference frame, then the effect of weak measurement will be weakened for the amplitude damping channel. Nevertheless, for other decoherence channels, the Unruh effect does not affect the quantum weak measurement, the only exception is that the maximum value of entanglement is reduced to √2/2 of the original value in the inertial frames. (general)

  15. Sparsity and spectral properties of dual frames

    DEFF Research Database (Denmark)

    Krahmer, Felix; Kutyniok, Gitta; Lemvig, Jakob

    2013-01-01

    We study sparsity and spectral properties of dual frames of a given finite frame. We show that any finite frame has a dual with no more than $n^2$ non-vanishing entries, where $n$ denotes the ambient dimension, and that for most frames no sparser dual is possible. Moreover, we derive an expressio...

  16. Some equalities and inequalities for fusion frames

    OpenAIRE

    Guo, Qianping; Leng, Jinsong; Li, Houbiao

    2016-01-01

    Fusion frames have some properties similar to those of frames in Hilbert spaces, but not all of their properties are similar. Some authors have established some equalities and inequalities for conventional frames. In this paper, we give some equalities and inequalities for fusion frames. Our results generalize and improve the remarkable results which have been obtained by Balan, Casazza and G?vruta etc.

  17. 49 CFR 393.201 - Frames.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Frames. 393.201 Section 393.201 Transportation... SAFE OPERATION Frames, Cab and Body Components, Wheels, Steering, and Suspension Systems § 393.201 Frames. (a) The frame or chassis of each commercial motor vehicle shall not be cracked, loose, sagging or...

  18. Key Frame Extraction in the Summary Space.

    Science.gov (United States)

    Li, Xuelong; Zhao, Bin; Lu, Xiaoqiang; Xuelong Li; Bin Zhao; Xiaoqiang Lu; Lu, Xiaoqiang; Li, Xuelong; Zhao, Bin

    2018-06-01

    Key frame extraction is an efficient way to create the video summary which helps users obtain a quick comprehension of the video content. Generally, the key frames should be representative of the video content, meanwhile, diverse to reduce the redundancy. Based on the assumption that the video data are near a subspace of a high-dimensional space, a new approach, named as key frame extraction in the summary space, is proposed for key frame extraction in this paper. The proposed approach aims to find the representative frames of the video and filter out similar frames from the representative frame set. First of all, the video data are mapped to a high-dimensional space, named as summary space. Then, a new representation is learned for each frame by analyzing the intrinsic structure of the summary space. Specifically, the learned representation can reflect the representativeness of the frame, and is utilized to select representative frames. Next, the perceptual hash algorithm is employed to measure the similarity of representative frames. As a result, the key frame set is obtained after filtering out similar frames from the representative frame set. Finally, the video summary is constructed by assigning the key frames in temporal order. Additionally, the ground truth, created by filtering out similar frames from human-created summaries, is utilized to evaluate the quality of the video summary. Compared with several traditional approaches, the experimental results on 80 videos from two datasets indicate the superior performance of our approach.

  19. Study and simulation of a multi-lithology stratigraphic model under maximum erosion rate constraint; Etude et simulation d'un modele statigraphique multi-lithologique sous contrainte de taux d'erosion maximal

    Energy Technology Data Exchange (ETDEWEB)

    Gervais, V.

    2004-11-01

    The subject of this report is the study and simulation of a model describing the infill of sedimentary basins on large scales in time and space. It simulates the evolution through time of the sediment layer in terms of geometry and rock properties. A parabolic equation is coupled to an hyperbolic equation by an input boundary condition at the top of the basin. The model also considers a unilaterality constraint on the erosion rate. In the first part of the report, the mathematical model is described and particular solutions are defined. The second part deals with the definition of numerical schemes and the simulation of the model. In the first chap-ter, finite volume numerical schemes are defined and studied. The Newton algorithm adapted to the unilateral constraint used to solve the schemes is given, followed by numerical results in terms of performance and accuracy. In the second chapter, a preconditioning strategy to solve the linear system by an iterative solver at each Newton iteration is defined, and numerical results are given. In the last part, a simplified model is considered in which a variable is decoupled from the other unknowns and satisfies a parabolic equation. A weak formulation is defined for the remaining coupled equations, for which the existence of a unique solution is obtained. The proof uses the convergence of a numerical scheme. (author)

  20. Framing and misperception in public good experiments

    DEFF Research Database (Denmark)

    Fosgaard, Toke Reinholt; Hansen, Lars Gårn; Wengström, Erik Roland

    2017-01-01

    Earlier studies have found that framing has substantial impact on the degree of cooperation observed in public good experiments. We show that the way the public good game is framed affects misperceptions about the incentives of the game. Moreover, we show that such framing-induced differences...... in misperceptions are linked to the framing effect on subjects' cooperation behavior. When we do not control for the different levels of misperceptions between frames, we observe a significant framing effect on subjects’ cooperation preferences. However, this framing effect becomes insignificant once we remove...

  1. Media framing and social movements

    NARCIS (Netherlands)

    Vliegenthart, R.; Snow, D.A.; Della Porta, D.; Klandermans, B.; McAdam, D.

    2013-01-01

    In their study of media content, mass communication scholars commonly rely on Entman's (1993: 52) definition of framing: "[selecting] some aspects of a perceived reality and make them more salient in a communicating text, in such a way as to promote a particular problem definition, causal

  2. On framed simple Lie groups

    OpenAIRE

    MINAMI, Haruo

    2016-01-01

    For a compact simple Lie group $G$, we show that the element $[G, \\mathcal{L}] \\in \\pi^S_*(S^0)$ represented by the pair $(G, \\mathcal{L})$ is zero, where $\\mathcal{L}$ denotes the left invariant framing of $G$. The proof relies on the method of E. Ossa [Topology, 21 (1982), 315–323].

  3. Handedness differences in information framing.

    Science.gov (United States)

    Jasper, John D; Fournier, Candice; Christman, Stephen D

    2014-02-01

    Previous research has shown that strength of handedness predicts differences in sensory illusions, Stroop interference, episodic memory, and beliefs about body image. Recent evidence also suggests handedness differences in the susceptibility to common decision biases such as anchoring and sunk cost. The present paper extends this line of work to attribute framing effects. Sixty-three undergraduates were asked to advise a friend concerning the use of a safe allergy medication during pregnancy. A third of the participants received negatively-framed information concerning the fetal risk of the drug (1-3% chance of having a malformed child); another third received positively-framed information (97-99% chance of having a normal child); and the final third received no counseling information and served as the control. Results indicated that, as predicted, inconsistent (mixed)-handers were more responsive than consistent (strong)-handers to information changes and readily update their beliefs. Although not significant, the data also suggested that only inconsistent handers were affected by information framing. Theoretical implications as well as ongoing work in holistic versus analytic processing, contextual sensitivity, and brain asymmetry will be discussed. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Meta framing and polyphonic structures

    DEFF Research Database (Denmark)

    Pedersen, Karsten

    2017-01-01

    in various ways in BT’s 2012 coverage of a doping case involving Riis. In this article I investigate the way in which BT meta frames itself and its own actions in order to show and underline the seriousness with which BT treats sports journalism. The study is part of a recurring Danish project harvesting...

  5. Reference frame for Product Configuration

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Oddsson, Gudmundur Valur

    2011-01-01

    a reference frame for configuration that permits 1) a more precise understanding of a configuration system, 2) a understanding of how the configuration system relate to other systems, and 3) a definition of the basic concepts in configuration. The total configuration system, together with the definition...

  6. Plasma physics in noninertial frames

    International Nuclear Information System (INIS)

    Thyagaraja, A.; McClements, K. G.

    2009-01-01

    Equations describing the nonrelativistic motion of a charged particle in an arbitrary noninertial reference frame are derived from the relativistically invariant form of the particle action. It is shown that the equations of motion can be written in the same form in inertial and noninertial frames, with the effective electric and magnetic fields in the latter modified by inertial effects associated with centrifugal and Coriolis accelerations. These modifications depend on the particle charge-to-mass ratio, and also the vorticity, specific kinetic energy, and compressibility of the frame flow. The Newton-Lorentz, Vlasov, and Fokker-Planck equations in such a frame are derived. Reduced models such as gyrokinetic, drift-kinetic, and fluid equations are then derivable from these equations in the appropriate limits, using standard averaging procedures. The results are applied to tokamak plasmas rotating about the machine symmetry axis with a nonrelativistic but otherwise arbitrary toroidal flow velocity. Astrophysical applications of the analysis are also possible since the power of the action principle is such that it can be used to describe relativistic flows in curved spacetime.

  7. Framing the future of fracking

    NARCIS (Netherlands)

    Metze, Tamara

    2017-01-01

    Hydraulic fracturing is a technology developed to improve and increase the production of natural gas. In many countries, including the Netherlands, it has caused environmental controversies. In these controversies, 'futurity framing' may open up debates for alternative paradigms such as

  8. Frames and generalized shift-invariant systems

    DEFF Research Database (Denmark)

    Christensen, Ole

    2004-01-01

    With motivation from the theory of Hilbert-Schmidt operators we review recent topics concerning frames in L 2 (R) and their duals. Frames are generalizations of orthonormal bases in Hilbert spaces. As for an orthonormal basis, a frame allows each element in the underlying Hilbert space...... to be written as an unconditionally convergent infinite linear combination of the frame elements; however, in contrast to the situation for a basis, the coefficients might not be unique. We present the basic facts from frame theory and the motivation for the fact that most recent research concentrates on tight...... frames or dual frame pairs rather than general frames and their canonical dual. The corresponding results for Gabor frames and wavelet frames are discussed in detail....

  9. On the structures of Grassmannian frames

    OpenAIRE

    Haas IV, John I.; Casazza, Peter G.

    2017-01-01

    A common criterion in the design of finite Hilbert space frames is minimal coherence, as this leads to error reduction in various signal processing applications. Frames that achieve minimal coherence relative to all unit-norm frames are called Grassmannian frames, a class which includes the well-known equiangular tight frames. However, the notion of "coherence minimization" varies according to the constraints of the ambient optimization problem, so there are other types of "minimally coherent...

  10. Dispositional optimism, self-framing and medical decision-making.

    Science.gov (United States)

    Zhao, Xu; Huang, Chunlei; Li, Xuesong; Zhao, Xin; Peng, Jiaxi

    2015-03-01

    Self-framing is an important but underinvestigated area in risk communication and behavioural decision-making, especially in medical settings. The present study aimed to investigate the relationship among dispositional optimism, self-frame and decision-making. Participants (N = 500) responded to the Life Orientation Test-Revised and self-framing test of medical decision-making problem. The participants whose scores were higher than the middle value were regarded as highly optimistic individuals. The rest were regarded as low optimistic individuals. The results showed that compared to the high dispositional optimism group, participants from the low dispositional optimism group showed a greater tendency to use negative vocabulary to construct their self-frame, and tended to choose the radiation therapy with high treatment survival rate, but low 5-year survival rate. Based on the current findings, it can be concluded that self-framing effect still exists in medical situation and individual differences in dispositional optimism can influence the processing of information in a framed decision task, as well as risky decision-making. © 2014 International Union of Psychological Science.

  11. Predicting statistical properties of open reading frames in bacterial genomes.

    Directory of Open Access Journals (Sweden)

    Katharina Mir

    Full Text Available An analytical model based on the statistical properties of Open Reading Frames (ORFs of eubacterial genomes such as codon composition and sequence length of all reading frames was developed. This new model predicts the average length, maximum length as well as the length distribution of the ORFs of 70 species with GC contents varying between 21% and 74%. Furthermore, the number of annotated genes is predicted with high accordance. However, the ORF length distribution in the five alternative reading frames shows interesting deviations from the predicted distribution. In particular, long ORFs appear more often than expected statistically. The unexpected depletion of stop codons in these alternative open reading frames cannot completely be explained by a biased codon usage in the +1 frame. While it is unknown if the stop codon depletion has a biological function, it could be due to a protein coding capacity of alternative ORFs exerting a selection pressure which prevents the fixation of stop codon mutations. The comparison of the analytical model with bacterial genomes, therefore, leads to a hypothesis suggesting novel gene candidates which can now be investigated in subsequent wet lab experiments.

  12. Halo-independence with quantified maximum entropy at DAMA/LIBRA

    Energy Technology Data Exchange (ETDEWEB)

    Fowlie, Andrew, E-mail: andrew.j.fowlie@googlemail.com [ARC Centre of Excellence for Particle Physics at the Tera-scale, Monash University, Melbourne, Victoria 3800 (Australia)

    2017-10-01

    Using the DAMA/LIBRA anomaly as an example, we formalise the notion of halo-independence in the context of Bayesian statistics and quantified maximum entropy. We consider an infinite set of possible profiles, weighted by an entropic prior and constrained by a likelihood describing noisy measurements of modulated moments by DAMA/LIBRA. Assuming an isotropic dark matter (DM) profile in the galactic rest frame, we find the most plausible DM profiles and predictions for unmodulated signal rates at DAMA/LIBRA. The entropic prior contains an a priori unknown regularisation factor, β, that describes the strength of our conviction that the profile is approximately Maxwellian. By varying β, we smoothly interpolate between a halo-independent and a halo-dependent analysis, thus exploring the impact of prior information about the DM profile.

  13. Ultra-fast framing camera tube

    Science.gov (United States)

    Kalibjian, Ralph

    1981-01-01

    An electronic framing camera tube features focal plane image dissection and synchronized restoration of the dissected electron line images to form two-dimensional framed images. Ultra-fast framing is performed by first streaking a two-dimensional electron image across a narrow slit, thereby dissecting the two-dimensional electron image into sequential electron line images. The dissected electron line images are then restored into a framed image by a restorer deflector operated synchronously with the dissector deflector. The number of framed images on the tube's viewing screen is equal to the number of dissecting slits in the tube. The distinguishing features of this ultra-fast framing camera tube are the focal plane dissecting slits, and the synchronously-operated restorer deflector which restores the dissected electron line images into a two-dimensional framed image. The framing camera tube can produce image frames having high spatial resolution of optical events in the sub-100 picosecond range.

  14. Evaluation of Seismic Behavior of Steel Braced Frames with Controlled Rocking System and Energy Dissipating Fuses

    Directory of Open Access Journals (Sweden)

    Hassan Amirzehni

    2016-12-01

    Full Text Available The self-centering rocking steel braced frames are new type of seismic lateral-force resisting systems that are developed with aim to limiting structural damages, minimizing residual drifts on systems and creating easy and inexpensive reconstruction capability, after sever earthquakes. In Steel braced frames with controlled rocking system, column bases on seismic resisting frame are not attached to the foundation and the frame allowed to rock freely. The task of restoring the rotated frame to its initial location is on post-tensioned cables, which attaches top of the frame to foundation. The design of post tensioned stands and braced frame members is such that during earthquakes they remain in elastic region. Seismic energy, dissipates by plastic deformations in replaceable elements on each rock of frame. In current research work, the seismic behavior of this type of lateral resisting systems is evaluated. The research conducted on a one bay steel braced frame with controlled rocking system that is analyzed using nonlinear dynamic time history analysis (NLTHA procedure. The frame is subjected to JMA-Kobe and Northridge ground motions records that are scaled to unit, 1.2 and 1.5 times of maximum considered earthquake (MCE ground motion level intensity. Extracted results show that seismic behavior of this type of lateral force resisting systems are so desirable even under MCE ground motion levels. The only anxiety is about occurring fatigue in post-tensioned strands that endangers overall stability of system.

  15. Maximum stellar iron core mass

    Indian Academy of Sciences (India)

    60, No. 3. — journal of. March 2003 physics pp. 415–422. Maximum stellar iron core mass. F W GIACOBBE. Chicago Research Center/American Air Liquide ... iron core compression due to the weight of non-ferrous matter overlying the iron cores within large .... thermal equilibrium velocities will tend to be non-relativistic.

  16. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore. 11 refs., 4 figs

  17. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore

  18. A portable storage maximum thermometer

    International Nuclear Information System (INIS)

    Fayart, Gerard.

    1976-01-01

    A clinical thermometer storing the voltage corresponding to the maximum temperature in an analog memory is described. End of the measurement is shown by a lamp switch out. The measurement time is shortened by means of a low thermal inertia platinum probe. This portable thermometer is fitted with cell test and calibration system [fr

  19. Variance based OFDM frame synchronization

    Directory of Open Access Journals (Sweden)

    Z. Fedra

    2012-04-01

    Full Text Available The paper deals with a new frame synchronization scheme for OFDM systems and calculates the complexity of this scheme. The scheme is based on the computing of the detection window variance. The variance is computed in two delayed times, so a modified Early-Late loop is used for the frame position detection. The proposed algorithm deals with different variants of OFDM parameters including guard interval, cyclic prefix, and has good properties regarding the choice of the algorithm's parameters since the parameters may be chosen within a wide range without having a high influence on system performance. The verification of the proposed algorithm functionality has been performed on a development environment using universal software radio peripheral (USRP hardware.

  20. Neutron spectra unfolding with maximum entropy and maximum likelihood

    International Nuclear Information System (INIS)

    Itoh, Shikoh; Tsunoda, Toshiharu

    1989-01-01

    A new unfolding theory has been established on the basis of the maximum entropy principle and the maximum likelihood method. This theory correctly embodies the Poisson statistics of neutron detection, and always brings a positive solution over the whole energy range. Moreover, the theory unifies both problems of overdetermined and of underdetermined. For the latter, the ambiguity in assigning a prior probability, i.e. the initial guess in the Bayesian sense, has become extinct by virtue of the principle. An approximate expression of the covariance matrix for the resultant spectra is also presented. An efficient algorithm to solve the nonlinear system, which appears in the present study, has been established. Results of computer simulation showed the effectiveness of the present theory. (author)

  1. Predicting the Strength of Online News Frames

    Directory of Open Access Journals (Sweden)

    Hrvoje Jakopović

    2017-10-01

    Full Text Available Framing theory is one of the most significant approaches to understanding media and their potential impact on publics. Leaving aside that fact, the author finds that publicity effects seem to be dispersed and difficult to catch for public relations. This article employs a specific research design, which could be applied to public relations practice, namely with a view to observing correlations between specific media frames and individual frames. The approach is based on the typology of news frames. The author attributes negative, positive and neutral determinants to the types of frames in his empirical research. Online news regarding three transport organizations and the accompanying user comments (identified as negative, positive and neutral are analysed by means of the method of content and sentiment analysis. The author recognizes user comments and reviews as individual frames that take part in the creation of online image. Furthermore, he identifies the types of media frames as well as individual frames manifested as image, and undertakes correlation research in order to establish their prediction potential. The results expose the most frequently used types of media frames concerning the transport domain. The media are keen to report through the attribution of responsibility frame, and after that, through the economic frame and the conflict frame, but, on the other hand, they tend to neglect the human interest frame and the morality frame. The results show that specific types of news frames enable better prediction of user reactions. The economic frame and the human interest frame therefore represent the most predictable types of frame.

  2. Sovereignty Frames and Sovereignty Claims

    OpenAIRE

    Walker, Neil

    2013-01-01

    This essay argues that much of the contemporary confusion and controversy over the meaning and continuing utility of the concept of sovereignty stems from a failure to distinguish between sovereignty as a deep framing device for making sense of the modern legal and political word on the one hand, and the particular claims which are made on behalf of particular institutions, agencies, rules or other entities to possess sovereign authority on the other. The essay begins by providing a basic acc...

  3. Orthogonal Multiwavelet Frames in L2Rd

    Directory of Open Access Journals (Sweden)

    Liu Zhanwei

    2012-01-01

    Full Text Available We characterize the orthogonal frames and orthogonal multiwavelet frames in L2Rd with matrix dilations of the form (Df(x=detAf(Ax, where A is an arbitrary expanding d×d matrix with integer coefficients. Firstly, through two arbitrarily multiwavelet frames, we give a simple construction of a pair of orthogonal multiwavelet frames. Then, by using the unitary extension principle, we present an algorithm for the construction of arbitrarily many orthogonal multiwavelet tight frames. Finally, we give a general construction algorithm for orthogonal multiwavelet tight frames from a scaling function.

  4. Spacetime transformations from a uniformly accelerated frame

    International Nuclear Information System (INIS)

    Friedman, Yaakov; Scarr, Tzvi

    2013-01-01

    We use the generalized Fermi–Walker transport to construct a one-parameter family of inertial frames which are instantaneously comoving to a uniformly accelerated observer. We explain the connection between our approach and that of Mashhoon. We show that our solutions of uniformly accelerated motion have constant acceleration in the comoving frame. Assuming the weak hypothesis of locality, we obtain local spacetime transformations from a uniformly accelerated frame K′ to an inertial frame K. The spacetime transformations between two uniformly accelerated frames with the same acceleration are Lorentz. We compute the metric at an arbitrary point of a uniformly accelerated frame. (paper)

  5. Mars Science Laboratory Frame Manager for Centralized Frame Tree Database and Target Pointing

    Science.gov (United States)

    Kim, Won S.; Leger, Chris; Peters, Stephen; Carsten, Joseph; Diaz-Calderon, Antonio

    2013-01-01

    The FM (Frame Manager) flight software module is responsible for maintaining the frame tree database containing coordinate transforms between frames. The frame tree is a proper tree structure of directed links, consisting of surface and rover subtrees. Actual frame transforms are updated by their owner. FM updates site and saved frames for the surface tree. As the rover drives to a new area, a new site frame with an incremented site index can be created. Several clients including ARM and RSM (Remote Sensing Mast) update their related rover frames that they own. Through the onboard centralized FM frame tree database, client modules can query transforms between any two frames. Important applications include target image pointing for RSM-mounted cameras and frame-referenced arm moves. The use of frame tree eliminates cumbersome, error-prone calculations of coordinate entries for commands and thus simplifies flight operations significantly.

  6. Multiple Maximum Exposure Rates in Computerized Adaptive Testing

    Science.gov (United States)

    Ramon Barrada, Juan; Veldkamp, Bernard P.; Olea, Julio

    2009-01-01

    Computerized adaptive testing is subject to security problems, as the item bank content remains operative over long periods and administration time is flexible for examinees. Spreading the content of a part of the item bank could lead to an overestimation of the examinees' trait level. The most common way of reducing this risk is to impose a…

  7. Nitric-glycolic flowsheet testing for maximum hydrogen generation rate

    Energy Technology Data Exchange (ETDEWEB)

    Martino, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Williams, M. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    The Defense Waste Processing Facility (DWPF) at the Savannah River Site is developing for implementation a flowsheet with a new reductant to replace formic acid. Glycolic acid has been tested over the past several years and found to effectively replace the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the chemical generation of hydrogen and ammonia, allows purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective adjustment of the SRAT/SME rheology, and is favorable with respect to melter flammability. The objective of this work was to perform DWPF Chemical Process Cell (CPC) testing at conditions that would bound the catalytic hydrogen production for the nitric-glycolic flowsheet.

  8. veteran athletes exercise at higher maximum heart rates than

    African Journals Online (AJOL)

    HR responses in different sporting disciplines." All tests were performed in the ... blood pressure (BP) and HR were measured from the right arm while the subjects were in a supine and standing position. Diastolic BP (DBP) was defined as the ...

  9. Efficacy of the Frame and Hu mathematical model for the quantitative analysis of agents influencing growth of chick embryo fibroblasts

    International Nuclear Information System (INIS)

    Korohoda, K.; Czyz, J.

    1994-01-01

    The experiments on the effect of various sera and substratum surface area upon growth of chick embryo fibroblasts-like in secondary cultures are described and discussed on the grounds of a mathematical model for growth of anchorage-dependent cells proposed by Frame and Hu. The model and presented results demonstrate the mutual independence of the effects of agent influencing of rate of cell proliferation (i.e. accelerating or retarding growth) and the agents that modify the limitation of cell proliferation (i.e. maximum cell density at confluence). The model proposed by Frame and Hu due to its relative simplicity offers and easy mode of description and quantitative evaluation of experiments concerning cell growth regulation. It is shown that various sera added at constant concentration significantly modify the rate of cell proliferation with little effect upon the maximum cell density attainable. The cells grew much more slowly in the presence of calf serum than in the presence of chick serum and the addition of iron and zinc complexes to calf serum significantly accelerated cell growth. An increase in the substratum surface area by the addition of glass wool to culture vessels significantly increased cell density per constant volume of medium even when retardation of growth was observed. The results presented point to the need of direct cell counting for estimation of cell growth curves and discussion of effects of agents influencing parameters characterizing cell proliferation. (author). 34 refs, 5 figs, 2 tabs

  10. Maximum power point tracking-based control algorithm for PMSG wind generation system without mechanical sensors

    International Nuclear Information System (INIS)

    Hong, Chih-Ming; Chen, Chiung-Hsing; Tu, Chia-Sheng

    2013-01-01

    Highlights: ► This paper presents MPPT based control for optimal wind energy capture using RBFN. ► MPSO is adopted to adjust the learning rates to improve the learning capability. ► This technique can maintain the system stability and reach the desired performance. ► The EMF in the rotating reference frame is utilized in order to estimate speed. - Abstract: This paper presents maximum-power-point-tracking (MPPT) based control algorithms for optimal wind energy capture using radial basis function network (RBFN) and a proposed torque observer MPPT algorithm. The design of a high-performance on-line training RBFN using back-propagation learning algorithm with modified particle swarm optimization (MPSO) regulating controller for the sensorless control of a permanent magnet synchronous generator (PMSG). The MPSO is adopted in this study to adapt the learning rates in the back-propagation process of the RBFN to improve the learning capability. The PMSG is controlled by the loss-minimization control with MPPT below the base speed, which corresponds to low and high wind speed, and the maximum energy can be captured from the wind. Then the observed disturbance torque is feed-forward to increase the robustness of the PMSG system

  11. On Maximum Entropy and Inference

    Directory of Open Access Journals (Sweden)

    Luigi Gresele

    2017-11-01

    Full Text Available Maximum entropy is a powerful concept that entails a sharp separation between relevant and irrelevant variables. It is typically invoked in inference, once an assumption is made on what the relevant variables are, in order to estimate a model from data, that affords predictions on all other (dependent variables. Conversely, maximum entropy can be invoked to retrieve the relevant variables (sufficient statistics directly from the data, once a model is identified by Bayesian model selection. We explore this approach in the case of spin models with interactions of arbitrary order, and we discuss how relevant interactions can be inferred. In this perspective, the dimensionality of the inference problem is not set by the number of parameters in the model, but by the frequency distribution of the data. We illustrate the method showing its ability to recover the correct model in a few prototype cases and discuss its application on a real dataset.

  12. Maximum Water Hammer Sensitivity Analysis

    OpenAIRE

    Jalil Emadi; Abbas Solemani

    2011-01-01

    Pressure waves and Water Hammer occur in a pumping system when valves are closed or opened suddenly or in the case of sudden failure of pumps. Determination of maximum water hammer is considered one of the most important technical and economical items of which engineers and designers of pumping stations and conveyance pipelines should take care. Hammer Software is a recent application used to simulate water hammer. The present study focuses on determining significance of ...

  13. Maximum Gene-Support Tree

    Directory of Open Access Journals (Sweden)

    Yunfeng Shan

    2008-01-01

    Full Text Available Genomes and genes diversify during evolution; however, it is unclear to what extent genes still retain the relationship among species. Model species for molecular phylogenetic studies include yeasts and viruses whose genomes were sequenced as well as plants that have the fossil-supported true phylogenetic trees available. In this study, we generated single gene trees of seven yeast species as well as single gene trees of nine baculovirus species using all the orthologous genes among the species compared. Homologous genes among seven known plants were used for validation of the finding. Four algorithms—maximum parsimony (MP, minimum evolution (ME, maximum likelihood (ML, and neighbor-joining (NJ—were used. Trees were reconstructed before and after weighting the DNA and protein sequence lengths among genes. Rarely a gene can always generate the “true tree” by all the four algorithms. However, the most frequent gene tree, termed “maximum gene-support tree” (MGS tree, or WMGS tree for the weighted one, in yeasts, baculoviruses, or plants was consistently found to be the “true tree” among the species. The results provide insights into the overall degree of divergence of orthologous genes of the genomes analyzed and suggest the following: 1 The true tree relationship among the species studied is still maintained by the largest group of orthologous genes; 2 There are usually more orthologous genes with higher similarities between genetically closer species than between genetically more distant ones; and 3 The maximum gene-support tree reflects the phylogenetic relationship among species in comparison.

  14. LCLS Maximum Credible Beam Power

    International Nuclear Information System (INIS)

    Clendenin, J.

    2005-01-01

    The maximum credible beam power is defined as the highest credible average beam power that the accelerator can deliver to the point in question, given the laws of physics, the beam line design, and assuming all protection devices have failed. For a new accelerator project, the official maximum credible beam power is determined by project staff in consultation with the Radiation Physics Department, after examining the arguments and evidence presented by the appropriate accelerator physicist(s) and beam line engineers. The definitive parameter becomes part of the project's safety envelope. This technical note will first review the studies that were done for the Gun Test Facility (GTF) at SSRL, where a photoinjector similar to the one proposed for the LCLS is being tested. In Section 3 the maximum charge out of the gun for a single rf pulse is calculated. In Section 4, PARMELA simulations are used to track the beam from the gun to the end of the photoinjector. Finally in Section 5 the beam through the matching section and injected into Linac-1 is discussed

  15. Development and Performance of Bechtel Nevada's Nine-Frame Camera System

    International Nuclear Information System (INIS)

    S. A. Baker; M. J. Griffith; J. L. Tybo

    2002-01-01

    Bechtel Nevada, Los Alamos Operations, has developed a high-speed, nine-frame camera system that records a sequence from a changing or dynamic scene. The system incorporates an electrostatic image tube with custom gating and deflection electrodes. The framing tube is shuttered with high-speed gating electronics, yielding frame rates of up to 5MHz. Dynamic scenes are lens-coupled to the camera, which contains a single photocathode gated on and off to control each exposure time. Deflection plates and drive electronics move the frames to different locations on the framing tube output. A single charge-coupled device (CCD) camera then records the phosphor image of all nine frames. This paper discusses setup techniques to optimize system performance. It examines two alternate philosophies for system configuration and respective performance results. We also present performance metrics for system evaluation, experimental results, and applications to four-frame cameras

  16. Characterization of Oblique Dual Frame Pairs

    DEFF Research Database (Denmark)

    Christensen, Ole; Eldar, Yonina

    2006-01-01

    Given a frame for a subspace W of a Hilbert space H, we consider all possible families of oblique dual frame vectors on an appropriately chosen subspace V. In place of the standard description, which involves computing the pseudoinverse of the frame operator, we develop an alternative characteriz...... for the case of shift-invariant spaces with a single generator. The theory is also adapted to the standard frame setting in which the original and dual frames are defined on the same space. Copyright (C) 2006 Hindawi Publishing Corporation. All rights reserved.......Given a frame for a subspace W of a Hilbert space H, we consider all possible families of oblique dual frame vectors on an appropriately chosen subspace V. In place of the standard description, which involves computing the pseudoinverse of the frame operator, we develop an alternative...

  17. 100-ps framing-camera tube

    International Nuclear Information System (INIS)

    Kalibjian, R.

    1978-01-01

    The optoelectronic framing-camera tube described is capable of recording two-dimensional image frames with high spatial resolution in the <100-ps range. Framing is performed by streaking a two-dimensional electron image across narrow slits. The resulting dissected electron line images from the slits are restored into framed images by a restorer deflector operating synchronously with the dissector deflector. The number of framed images on the tube's viewing screen equals the number of dissecting slits in the tube. Performance has been demonstrated in a prototype tube by recording 135-ps-duration framed images of 2.5-mm patterns at the cathode. The limitation in the framing speed is in the external drivers for the deflectors and not in the tube design characteristics. Faster frame speeds in the <100-ps range can be obtained by use of faster deflection drivers

  18. Mercury's Reference Frames After the MESSENGER Mission

    Science.gov (United States)

    Stark, A.; Oberst, J.; Preusker, F.; Burmeister, S.; Steinbrügge, G.; Hussmann, H.

    2018-05-01

    We provide an overview of Mercury's reference frames based on MESSENGER observations. We discuss the dynamical, the principal-axes, the ellipsoid, as well as the cartographic frame, which was adopted for MESSENGER data products.

  19. Mechanical Energy Change in Inertial Reference Frames

    Science.gov (United States)

    Ghanbari, Saeed

    2016-01-01

    The mechanical energy change of a system in an inertial frame of reference equals work done by the total nonconservative force in the same frame. This relation is covariant under the Galilean transformations from inertial frame S to S', where S' moves with constant velocity relative to S. In the presence of nonconservative forces, such as normal…

  20. Framing, intentions, and trust-choice incompatibility

    NARCIS (Netherlands)

    Keren, G.B.

    2007-01-01

    The present paper examines how framing of messages and the intentions inferred from different—positive vs. negative—framings, interact with the development of trust. Empirical evidence is presented showing that different, logically equivalent, frames are supposedly interpreted as implying different

  1. Inertial reference frames and gravitational forces

    International Nuclear Information System (INIS)

    Santavy, I.

    1981-01-01

    The connection between different definitions of inertial, i.e. fundamental, reference frames and the corresponding characterisation of gravitational fields by gravitational forces are considered from the point of view of their possible interpretation in university introductory courses. The introduction of a special class of reference frames, denoted 'mixed reference frames' is proposed and discussed. (author)

  2. Computable Frames in Computable Banach Spaces

    Directory of Open Access Journals (Sweden)

    S.K. Kaushik

    2016-06-01

    Full Text Available We develop some parts of the frame theory in Banach spaces from the point of view of Computable Analysis. We define computable M-basis and use it to construct a computable Banach space of scalar valued sequences. Computable Xd frames and computable Banach frames are also defined and computable versions of sufficient conditions for their existence are obtained.

  3. Information Leakage from Logically Equivalent Frames

    Science.gov (United States)

    Sher, Shlomi; McKenzie, Craig R. M.

    2006-01-01

    Framing effects are said to occur when equivalent frames lead to different choices. However, the equivalence in question has been incompletely conceptualized. In a new normative analysis of framing effects, we complete the conceptualization by introducing the notion of information equivalence. Information equivalence obtains when no…

  4. Influence of framing on medical decision making

    OpenAIRE

    Feng, Jun; Gong, Jingjing; Huang, Yonghua; Wei, Yazhou; Zhang, Weiwei; Zhang, Yan

    2013-01-01

    Numerous studies have demonstrated the robustness of the framing effect in a variety of contexts, especially in medical decision making. Unfortunately, research is still inconsistent as to how so many variables impact framing effects in medical decision making. Additionally, much attention should be paid to the framing effect not only in hypothetical scenarios but also in clinical experience.

  5. Influence of framing on medical decision making.

    Science.gov (United States)

    Gong, Jingjing; Zhang, Yan; Feng, Jun; Huang, Yonghua; Wei, Yazhou; Zhang, Weiwei

    2013-01-01

    Numerous studies have demonstrated the robustness of the framing effect in a variety of contexts, especially in medical decision making. Unfortunately, research is still inconsistent as to how so many variables impact framing effects in medical decision making. Additionally, much attention should be paid to the framing effect not only in hypothetical scenarios but also in clinical experience.

  6. Influence of framing on medical decision making

    Science.gov (United States)

    Gong, Jingjing; Zhang, Yan; Feng, Jun; Huang, Yonghua; Wei, Yazhou; Zhang, Weiwei

    2013-01-01

    Numerous studies have demonstrated the robustness of the framing effect in a variety of contexts, especially in medical decision making. Unfortunately, research is still inconsistent as to how so many variables impact framing effects in medical decision making. Additionally, much attention should be paid to the framing effect not only in hypothetical scenarios but also in clinical experience. PMID:27034630

  7. Evaluation and the Framing of Race

    Science.gov (United States)

    House, Ernest R.

    2017-01-01

    Racial framing can have strong effects on programs, policies, and even evaluations. Racial framing developed as a justification for the exploitation of minorities and has been a primary causal factor in the persistence of racism. By being aware of its pattern, structure, origins, and how racial framing generates effects, we can significantly…

  8. 10 CFR 710.35 - Time frames.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...

  9. 21 CFR 886.5842 - Spectacle frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Spectacle frame. 886.5842 Section 886.5842 Food... DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5842 Spectacle frame. (a) Identification. A spectacle frame is a device made of metal or plastic intended to hold prescription spectacle lenses worn by a...

  10. Common Frame of Reference and social justice

    NARCIS (Netherlands)

    Hesselink, M.W.; Satyanarayana, R.

    2009-01-01

    The article "Common Frame of Reference and Social Justice" by Martijn W. Hesselink evaluates the Draft Common Frame of Reference (DCFR) of social justice. It discusses the important areas, namely a common frame of Reference in a broad sense, social justice and contract law, private law and

  11. Cooperation, framing and political attitudes

    DEFF Research Database (Denmark)

    Fosgaard, Toke Reinholt; Hansen, Lars Gårn; Wengström, Erik Roland

    This paper shows that political attitudes are linked to cooperative behavior in an incentivized experiment with a large sample randomly drawn from the Danish population. However, this relationship depends on the way the experiment is framed. In the standard game in which subjects give to a public...... good, contributions are the same regardless of political attitudes. In an economically equivalent version, in which subjects take from a public good, left-wingers cooperate significantly more than subjects in the middle or to the right of the political spectrum. Through simulation techniques we find...

  12. Meta framing and polyphonic structures

    DEFF Research Database (Denmark)

    Pedersen, Karsten

    2017-01-01

    in various ways in BT’s 2012 coverage of a doping case involving Riis. In this article I investigate the way in which BT meta frames itself and its own actions in order to show and underline the seriousness with which BT treats sports journalism. The study is part of a recurring Danish project harvesting......The present case study deals with the Danish tabloid BT’s coverage of Cycling team owner Bjarne Riis’s possible knowledge of doping use in his cycling teams. BT sees itself as a sports paper and tries to signal that it takes sports coverage as seriously other kinds of news. We see that reflected...

  13. Generic maximum likely scale selection

    DEFF Research Database (Denmark)

    Pedersen, Kim Steenstrup; Loog, Marco; Markussen, Bo

    2007-01-01

    in this work is on applying this selection principle under a Brownian image model. This image model provides a simple scale invariant prior for natural images and we provide illustrative examples of the behavior of our scale estimation on such images. In these illustrative examples, estimation is based......The fundamental problem of local scale selection is addressed by means of a novel principle, which is based on maximum likelihood estimation. The principle is generally applicable to a broad variety of image models and descriptors, and provides a generic scale estimation methodology. The focus...

  14. Framing Effects: Dynamics and Task Domains

    Science.gov (United States)

    Wang

    1996-11-01

    The author examines the mechanisms and dynamics of framing effects in risky choices across three distinct task domains (i.e., life-death, public property, and personal money). The choice outcomes of the problems presented in each of the three task domains had a binary structure of a sure thing vs a gamble of equal expected value; the outcomes differed in their framing conditions and the expected values, raging from 6000, 600, 60, to 6, numerically. It was hypothesized that subjects would become more risk seeking, if the sure outcome was below their aspiration level (the minimum requirement). As predicted, more subjects preferred the gamble when facing the life-death choice problems than facing the counterpart problems presented in the other two task domains. Subjects' risk preference varied categorically along the group size dimension in the life-death domain but changed more linearly over the expected value dimension in the monetary domain. Framing effects were observed in 7 of 13 pairs of problems, showing a positive frame-risk aversion and negative frame-risk seeking relationship. In addition, two types of framing effects were theoretically defined and empirically identified. A bidirectional framing effect involves a reversal in risk preference, and occurs when a decision maker's risk preference is ambiguous or weak. Four bidirectional effects were observed; in each case a majority of subjects preferred the sure outcome under a positive frame but the gamble under a negative frame. In contrast, a unidirectional framing effect refers to a preference shift due to the framing of choice outcomes: A majority of subjects preferred one choice outcome (either the sure thing or the gamble) under both framing conditions, with positive frame augmented the preference for the sure thing and negative frame augmented the preference for the gamble. These findings revealed some dynamic regularities of framing effects and posed implications for developing predictive and testable

  15. Effects of Data Frame Size Distribution on Wireless Lans | Aneke ...

    African Journals Online (AJOL)

    IEEE 802.11 WLAN is known to achieve relatively small throughput performance compared to the underlying physical layer's transmission rate and this is as a result of large overhead information composed of medium access control header, physical layer preamble information back-off duration control frames (ACK) ...

  16. ORIGINAL ARTICLES Surgical practice in a maximum security prison

    African Journals Online (AJOL)

    Prison Clinic, Mangaung Maximum Security Prison, Bloemfontein. F Kleinhans, BA (Cur) .... HIV positivity rate and the use of the rectum to store foreign objects. ... fruit in sunlight. Other positive health-promoting factors may also play a role,.

  17. Symmetries of collective models in intrinsic frame

    International Nuclear Information System (INIS)

    Gozdz, A.; Pedrak, A.; Szulerecka, A.; Dobrowolski, A.; Dudek, J.

    2013-01-01

    In the paper a very general definition of intrinsic frame, by means of group theoretical methods, is introduced. It allows to analyze nuclear properties which are invariant in respect to the group which defines the intrinsic frame. For example, nuclear shape is a well determined feature in the intrinsic frame defined by the Euclidean group. It is shown that using of intrinsic frame gives an opportunity to consider intrinsic nuclear symmetries which are independent of symmetries observed in the laboratory frame. An importance of the notion of partial symmetries is emphasized. (author)

  18. Extreme Maximum Land Surface Temperatures.

    Science.gov (United States)

    Garratt, J. R.

    1992-09-01

    There are numerous reports in the literature of observations of land surface temperatures. Some of these, almost all made in situ, reveal maximum values in the 50°-70°C range, with a few, made in desert regions, near 80°C. Consideration of a simplified form of the surface energy balance equation, utilizing likely upper values of absorbed shortwave flux (1000 W m2) and screen air temperature (55°C), that surface temperatures in the vicinity of 90°-100°C may occur for dry, darkish soils of low thermal conductivity (0.1-0.2 W m1 K1). Numerical simulations confirm this and suggest that temperature gradients in the first few centimeters of soil may reach 0.5°-1°C mm1 under these extreme conditions. The study bears upon the intrinsic interest of identifying extreme maximum temperatures and yields interesting information regarding the comfort zone of animals (including man).

  19. Finite element simulation of shallow-buried and mining tunnelling in adjacent frame structures

    Directory of Open Access Journals (Sweden)

    Chun-lai Chen

    2014-05-01

    Full Text Available By using three dimensional software MIDAS/GTS, the interactions among structures-soil-tunnel system is considered in this paper, and the working condition of shallow-buried underground excavation is simulated in the foundation of frame structures with the short-pile. The loadings and deformations of structures are studied before and after the tunnelling, and the influences of the following factors, including the horizontal position of tunnel and building, the height of building and the soil property, are analyzed. It is indicated that when the horizontal distance L equals zero (the distance between building axis to the tunnel axis, the building settlement increases gradually and shows a normal distribution during and after the tunnelling. Due to the small stiffness of frame structures with short-pile foundations, the building has large nonuniform settlement. When the distance of excavation is no less than 1.8 times of the thickness of overburden soil, the building settlement becomes stable, and the first principal stress P1 and maximum deformation rate E1 generally show a trend of decrease. With the increasing L, P1 and E1 will decrease accordingly, and the buildings tend to be inclined toward the tunnel. For a relatively larger distance, the building is nearly not affected.

  20. Frame by Frame II: A Filmography of the African American Image, 1978-1994.

    Science.gov (United States)

    Klotman, Phyllis R.; Gibson, Gloria J.

    A reference guide on African American film professionals, this book is a companion volume to the earlier "Frame by Frame I." It focuses on giving credit to African Americans who have contributed their talents to a film industry that has scarcely recognized their contributions, building on the aforementioned "Frame by Frame I,"…

  1. Complex pulsing schemes for high frame rate imaging

    DEFF Research Database (Denmark)

    Misaridis, Thanassis; Fink, Mathias; Jensen, Jørgen Arendt

    2002-01-01

    up to a pulse train. The acoustically generated high time-bandwidth (TB) product waveforms can be compressed by using a filter bank of matched filters one for every beam direction. Matched filtering compresses the pulse train to a single pulse at the scatterer position plus a number of spike axial...... with linear frequency modulation along the transducer elements, that cover the 70% fractional bandwidth of the 7 MHz transducer. The resulted images (after beamforming and matched filtering) show an axial resolution at the same order as in conventional pulse excitation and axial sidelobes down to -45 d...

  2. Space-time encoding for high frame rate ultrasound imaging

    DEFF Research Database (Denmark)

    Misaridis, Thanssis; Jensen, Jørgen Arendt

    2002-01-01

    dynamically focused in both transmit and receive with only two firings. This reduces the problem of motion artifacts. The method has been tested with extensive simulations using Field II. Resolution and SNR are compared with uncoded STA imaging and conventional phased-array imaging. The range resolution...... remains the same for coded STA imaging with four emissions and is slightly degraded for STA imaging with two emissions due to the −55 dB cross-talk between the signals. The additional proposed temporal encoding adds more than 15 dB on the SNR gain, yielding a SNR at the same order as in phased-array...

  3. Frame Rate versus Spatial Quality: Which Video Characteristics Do Matter?

    DEFF Research Database (Denmark)

    Korhonen, Jari; Reiter, Ulrich; Ukhanova, Ann

    2013-01-01

    and temporal quality levels. We also propose simple yet powerful metrics for characterizing spatial and temporal properties of a video sequence, and demonstrate how these metrics can be applied for evaluating the relative impact of spatial and temporal quality on the perceived overall quality....

  4. Message framing in social networking sites.

    Science.gov (United States)

    Kao, Danny Tengti; Chuang, Shih-Chieh; Wang, Sui-Min; Zhang, Lei

    2013-10-01

    Online social networking sites represent significant new opportunities for Internet advertisers. However, results based on the real world cannot be generalized to all virtual worlds. In this research, the moderating effects of need for cognition (NFC) and knowledge were applied to examine the impact of message framing on attitudes toward social networking sites. A total of 216 undergraduates participated in the study. Results reveal that for social networking sites, while high-NFC individuals form more favorable attitudes toward negatively framed messages than positively framed messages, low-NFC individuals form more favorable attitudes toward positively framed messages than negatively framed messages. In addition, low-knowledge individuals demonstrate more favorable attitudes toward negatively framed messages than positively framed messages; however, the framing effect does not differentially affect the attitudes of high-knowledge individuals. Furthermore, the framing effect does not differentially affect the attitudes of high-NFC individuals with high knowledge. In contrast, low-NFC individuals with low knowledge hold more favorable attitudes toward positively framed messages than negatively framed messages.

  5. COMPARING FRAMES, FRAMING COMPARISONS: GREECE/EU FRAMES ON GENDER INEQUALITY IN POLITICS

    OpenAIRE

    Maloutas, Maro Pantelidou

    2016-01-01

    This article intends to present the main similarities and differences between Greece and the EU in respect to the framing of gender inequality in political decision making as a policy issue, based on the ways that the problem is diagnosed. It also aims at the formulation of a hypothesis which argues that beyond the above similarities and differences, which may tint in a different colour measures and policies showing one case more gender sensitive or more «traditional» than the other, there ex...

  6. Frames, operator representations, and open problems

    DEFF Research Database (Denmark)

    Christensen, Ole; Hasannasab, Marzieh

    2018-01-01

    , a topic that has recently attracted considerably interest within harmonic analysis. The goal of the paper is twofold, namely, that experts in operator theory will explore the potential of frames, and that frame theory will benefit from insight provided by the operator theory community.......A frame in a Hilbert space H is a countable collection of elements in H that allows each f ϵ H to be expanded as an (infinite) linear combination of the frame elements. Frames generalize the wellknown orthonormal bases, but provide much more exibility and can often be constructed with properties...... that are not possible for orthonormal bases. We will present the basic facts in frame theory with focus on their operator theoretical characterizations and discuss open problems concerning representations of frames in terms of iterations of a fixed operator. These problems come up in the context of dynamical sampling...

  7. Technological Frame Incongruence, Diffusion, and Noncompliance

    Science.gov (United States)

    Sobreperez, Polly

    The technological frames of reference strand of social shaping of technology theory is used to overlay the issues arising from a case study looking at noncompliance with information systems. A recent review of the theory suggests that although frame content is often addressed, frame structure, the process of framing, and the characteristics and outcomes of frames are largely overlooked. This paper attempts to address this shortfall by applying the indicators identified by case study research to the frames of different groups and using them to highlight differing perceptions and attitudes. In this way, the author suggests that issues surrounding noncompliance should not be dismissed as resistance but instead should be further studied by managers and developers, leading to accommodation of differing views. Further examination of frame incongruence reveals dependence on inefficient or ineffective organizational situations and thus these indicators can be useful in future studies to identify and address procedural, acceptance and cultural issues leading to acts of noncompliance.

  8. Towards a poetics of the cinematographic frame

    Directory of Open Access Journals (Sweden)

    Des O'Rawe

    2011-05-01

    Full Text Available In delineating a poetics of the cinematographic frame, this essay presents a typology of framing styles, and demonstrates ways in which filmmakers use the frame as an expressive resource—and ways in which the frame uses them. The examples discussed are modernist in orientation, and each has a particular association with a city—its history, architecture, and cultural character. Although it is common practice to refer to various—especially, modernist—framing situations as instances of deframing, the essay also enquires into the problematic nature of this term, suggesting alternative visual and cinematographic contexts more amenable to the deconstructive implications of this term. As the boundaries between cinema and the other arts continue to converge and relations between frame, image, and screen become more complex, this essay offers a reassessment of some first principles of film language, especially the aesthetic integrity of the cinematographic frame.

  9. An introduction to finite tight frames

    CERN Document Server

    Waldron, Shayne F D

    2018-01-01

    This textbook is an introduction to the theory and applications of finite tight frames, an area that has developed rapidly in the last decade. Stimulating much of this growth are the applications of finite frames to diverse fields such as signal processing, quantum information theory, multivariate orthogonal polynomials, and remote sensing. Key features and topics: * First book entirely devoted to finite frames * Extensive exercises and MATLAB examples for classroom use * Important examples, such as harmonic and Heisenberg frames, are presented in preliminary chapters, encouraging readers to explore and develop an intuitive feeling for tight frames * Later chapters delve into general theory details and recent research results * Many illustrations showing the special aspects of the geometry of finite frames * Provides an overview of the field of finite tight frames * Discusses future research directions in the field Featuring exercises and MATLAB examples in each chapter, the book is well suited as a textbook ...

  10. Characterization of Oblique Dual Frame Pairs

    Directory of Open Access Journals (Sweden)

    Christensen Ole

    2006-01-01

    Full Text Available Given a frame for a subspace of a Hilbert space , we consider all possible families of oblique dual frame vectors on an appropriately chosen subspace . In place of the standard description, which involves computing the pseudoinverse of the frame operator, we develop an alternative characterization which in some cases can be computationally more efficient. We first treat the case of a general frame on an arbitrary Hilbert space, and then specialize the results to shift-invariant frames with multiple generators. In particular, we present explicit versions of our general conditions for the case of shift-invariant spaces with a single generator. The theory is also adapted to the standard frame setting in which the original and dual frames are defined on the same space.

  11. "Think" versus "feel" framing effects in persuasion.

    Science.gov (United States)

    Mayer, Nicole D; Tormala, Zakary L

    2010-04-01

    Three studies explored think ("I think . . . ") versus feel ("I feel . . . ") message framing effects on persuasion.The authors propose a matching hypothesis, suggesting that think framing will be more persuasive when the target attitude or message recipient is cognitively oriented, whereas feel framing will be more persuasive when the target attitude or message recipient is affectively oriented. Study 1 presented cognitively and affectively oriented individuals with a think- or feel-framed message. Study 2 primed cognitive or affective orientation and then presented a think- or feel-framed message. Study 3 presented male and female participants with an advertisement containing think- or feel-framed arguments. Results indicated that think (feel) framing was more persuasive when the target attitude or recipient was cognitively (affectively) oriented. Moreover, Study 2 demonstrated that this matching effect was mediated by processing fluency. Theoretical and practical implications are discussed.

  12. Analisis Framing dalam Riset Public Relations

    Directory of Open Access Journals (Sweden)

    NARAYANA MAHENDRA PRASTYA

    2016-12-01

    Full Text Available This paper aims to give description about how to use frame analysis in Public Relations (PR research. The author use two framing models: Entman and Pan & Kosicki. The object is organization official statement about particular issue. Frame analysis method rarely used in Public Relations research. This methods commonly use in journalism study, to analyse the news in media. Meanwhile, the key word of framing is the social construction of reality. Organization can make social construction of realty in their official statement. In acacemic term, frame analysis in PR research is useful to know how organization positioned themselves in particular situation. Other benefit is use to evaluat whether the organization frame is conformable with the public opinion or agenda setting media or not. In practical term, frame analysis give benefit for PR practitioner to create the message that can be undserstood by public, also give positive image for organization.

  13. Effect of Various Interface Thicknesses on the Behaviour of Infilled frame Subjected to Lateral Load

    Science.gov (United States)

    Senthil, K.; Muthukumar, S.; Rupali, S.; Satyanarayanan, K. S.

    2018-03-01

    Two dimensional numerical investigations were carried out to study the influence of interface thickness on the behaviour of reinforced concrete frames subjected to in-plane lateral loads using commercial finite element tool SAP 2000. The cement mortar, cork and foam was used as interface material and their effect was studied by varying thicknesses as 6, 8, 10, 14 and 20 mm. The effect of lateral loads on infill masonry wall was also studied by varying arbitrary loads as 10, 20, 40 and 60 kN. The resistance of the frame with cement mortar was found maximum with the interface thickness 10 mm therefore, it is concluded that the maximum influence of interface thickness of 10 mm was found effective. The resistance of integral infill frame with cork and foam interface was found maximum with the interface thickness 6 mm and it is concluded that 6 mm thick interface among the chosen thickness was found effective.

  14. Approximately dual frames in Hilbert spaces and applications to Gabor frames

    OpenAIRE

    Christensen, Ole; Laugesen, Richard S.

    2011-01-01

    Approximately dual frames are studied in the Hilbert space setting. Approximate duals are easier to construct than classical dual frames, and can be tailored to yield almost perfect reconstruction. Bounds on the deviation from perfect reconstruction are obtained for approximately dual frames constructed via perturbation theory. An alternative bound is derived for the rich class of Gabor frames, by using the Walnut representation of the frame operator to estimate the deviation from equality in...

  15. System for memorizing maximum values

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1992-08-01

    The invention discloses a system capable of memorizing maximum sensed values. The system includes conditioning circuitry which receives the analog output signal from a sensor transducer. The conditioning circuitry rectifies and filters the analog signal and provides an input signal to a digital driver, which may be either linear or logarithmic. The driver converts the analog signal to discrete digital values, which in turn triggers an output signal on one of a plurality of driver output lines n. The particular output lines selected is dependent on the converted digital value. A microfuse memory device connects across the driver output lines, with n segments. Each segment is associated with one driver output line, and includes a microfuse that is blown when a signal appears on the associated driver output line.

  16. Remarks on the maximum luminosity

    Science.gov (United States)

    Cardoso, Vitor; Ikeda, Taishi; Moore, Christopher J.; Yoo, Chul-Moon

    2018-04-01

    The quest for fundamental limitations on physical processes is old and venerable. Here, we investigate the maximum possible power, or luminosity, that any event can produce. We show, via full nonlinear simulations of Einstein's equations, that there exist initial conditions which give rise to arbitrarily large luminosities. However, the requirement that there is no past horizon in the spacetime seems to limit the luminosity to below the Planck value, LP=c5/G . Numerical relativity simulations of critical collapse yield the largest luminosities observed to date, ≈ 0.2 LP . We also present an analytic solution to the Einstein equations which seems to give an unboundedly large luminosity; this will guide future numerical efforts to investigate super-Planckian luminosities.

  17. Maximum mutual information regularized classification

    KAUST Repository

    Wang, Jim Jing-Yan

    2014-09-07

    In this paper, a novel pattern classification approach is proposed by regularizing the classifier learning to maximize mutual information between the classification response and the true class label. We argue that, with the learned classifier, the uncertainty of the true class label of a data sample should be reduced by knowing its classification response as much as possible. The reduced uncertainty is measured by the mutual information between the classification response and the true class label. To this end, when learning a linear classifier, we propose to maximize the mutual information between classification responses and true class labels of training samples, besides minimizing the classification error and reducing the classifier complexity. An objective function is constructed by modeling mutual information with entropy estimation, and it is optimized by a gradient descend method in an iterative algorithm. Experiments on two real world pattern classification problems show the significant improvements achieved by maximum mutual information regularization.

  18. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  19. Maximum mutual information regularized classification

    KAUST Repository

    Wang, Jim Jing-Yan; Wang, Yi; Zhao, Shiguang; Gao, Xin

    2014-01-01

    In this paper, a novel pattern classification approach is proposed by regularizing the classifier learning to maximize mutual information between the classification response and the true class label. We argue that, with the learned classifier, the uncertainty of the true class label of a data sample should be reduced by knowing its classification response as much as possible. The reduced uncertainty is measured by the mutual information between the classification response and the true class label. To this end, when learning a linear classifier, we propose to maximize the mutual information between classification responses and true class labels of training samples, besides minimizing the classification error and reducing the classifier complexity. An objective function is constructed by modeling mutual information with entropy estimation, and it is optimized by a gradient descend method in an iterative algorithm. Experiments on two real world pattern classification problems show the significant improvements achieved by maximum mutual information regularization.

  20. Estimating Body Related Soft Biometric Traits in Video Frames

    Directory of Open Access Journals (Sweden)

    Olasimbo Ayodeji Arigbabu

    2014-01-01

    Full Text Available Soft biometrics can be used as a prescreening filter, either by using single trait or by combining several traits to aid the performance of recognition systems in an unobtrusive way. In many practical visual surveillance scenarios, facial information becomes difficult to be effectively constructed due to several varying challenges. However, from distance the visual appearance of an object can be efficiently inferred, thereby providing the possibility of estimating body related information. This paper presents an approach for estimating body related soft biometrics; specifically we propose a new approach based on body measurement and artificial neural network for predicting body weight of subjects and incorporate the existing technique on single view metrology for height estimation in videos with low frame rate. Our evaluation on 1120 frame sets of 80 subjects from a newly compiled dataset shows that the mentioned soft biometric information of human subjects can be adequately predicted from set of frames.

  1. Discursive Framings of Human Rights

    DEFF Research Database (Denmark)

    What does it mean to be a subject of human rights? The status of the subject is closely connected with the form and rhetoric of the framing discourse, and this book investigates the relationship between the status of the subject and the form of human rights discourse, in differing aesthetic...... and social contexts. Historical as well as contemporary declarations of rights have stressed both the protective and political aspects of human rights. But in concrete situations and conflictual moments, the high moral legitimacy of human rights rhetoric has often clouded the actual character of specific...... interventions, and so made it difficult to differentiate between the objects of humanitarian intervention and the subjects of politics. Critically re-examining this opposition – between victims and agents of human rights – through a focus on the ways in which discourses of rights are formed and circulated...

  2. Breaking bad news: Effects of forecasting diagnosis and framing prognosis.

    Science.gov (United States)

    Porensky, Emily K; Carpenter, Brian D

    2016-01-01

    Research to support guidelines for breaking bad news is lacking. This study used an experimental paradigm to test two communication strategies, forecasting bad news and framing prognosis, in the context of cancer. In a 2×2 design, 128 participants received bad news in a hypothetical consultation. A videotaped physician presented diagnostic and prognostic information, varying warning (warning shot vs. no warning), and framing (positive vs. negative). Effects on psychological distress, recall accuracy, and subjective interpretations of the news were assessed. Warning was not associated with lower psychological distress or improved recall. Individuals who heard a positively-framed prognosis had significantly less psychological distress, rated their prognosis better, and were more hopeful than those who heard a negatively-framed prognosis. However, they also showed a trend toward reduced accuracy in recalling prognostic statistics. Results contribute to a growing body of literature exploring optimal approaches for communicating bad news in health care. Although research in clinical settings is needed to bolster results, findings suggest that when providers use positive framing to reduce distress about prognosis, they should also consider ways to overcome potential reductions in recall accuracy, such as repeating statistical information or supplementing with written information. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Maximum Likelihood Approach for RFID Tag Set Cardinality Estimation with Detection Errors

    DEFF Research Database (Denmark)

    Nguyen, Chuyen T.; Hayashi, Kazunori; Kaneko, Megumi

    2013-01-01

    Abstract Estimation schemes of Radio Frequency IDentification (RFID) tag set cardinality are studied in this paper using Maximum Likelihood (ML) approach. We consider the estimation problem under the model of multiple independent reader sessions with detection errors due to unreliable radio...... is evaluated under dierent system parameters and compared with that of the conventional method via computer simulations assuming flat Rayleigh fading environments and framed-slotted ALOHA based protocol. Keywords RFID tag cardinality estimation maximum likelihood detection error...

  4. The influence of head frame distortions on stereotactic localization and targeting

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, H; Hunsche, S; Hoevels, M; Luyken, K; Maarouf, M; Voges, J; Sturm, V [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, 50924 Cologne (Germany)

    2004-09-07

    A strong attachment of a stereotactic head frame to the patient's skull may cause distortions of the head frame. The aim of this work was to identify possible distortions of the head frame, to measure the degree of distortion occurring in clinical practice and to investigate its influence on stereotactic localization and targeting. A model to describe and quantify the distortion of the Riechert-Mundinger (RM) head frame was developed. Distortions were classified as (a) bending and (b) changes from the circular ring shape. Ring shape changes were derived from stereotactic CT scans and frame bending was determined from intraoperative stereotactic x-ray images of patients with implanted {sup 125}I-seeds acting as landmarks. From the examined patient data frame bending was determined to be 0.74 mm {+-} 0.32 mm and 1.30 mm in maximum. If a CT-localizer with a top ring is used, frame bending has no influence on stereotactic CT-localization. In stereotactic x-ray localization, frame bending leads to an overestimation of the z-coordinate by 0.37 mm {+-} 0.16 mm on average and by 0.65 mm in maximum. The accuracy of patient positioning in radiosurgery is not affected by frame bending. But in stereotactic surgery with an RM aiming bow trajectory displacements are expected. These displacements were estimated to be 0.36 mm {+-} 0.16 mm (max. 0.74 mm) at the target point and 0.65 mm {+-} 0.30 mm (max. 1.31 mm) at the entry point level. Changes from the circular ring shape are small and do not compromise the accuracy of stereotactic targeting and localization. The accuracy of CT-localization was found to be close to the resolution limit due to voxel size. Our findings for frame bending of the RM frame could be validated by statistical analysis and by comparison with an independent patient examination. The results depend on the stereotactic system and details of the localizers and instruments and also reflect our clinical practice. Therefore, a generalization is not possible

  5. The Influence of Infill Wall Topology and Seismic Characteristics on the Response and Damage Distribution in Frame Structures

    Directory of Open Access Journals (Sweden)

    Nikos Nanos

    2013-01-01

    Full Text Available This paper identifies the effects of infill wall existence and arrangement in the seismic response of frame structures utilising the global structural damage index after Park/Ang (GDIPA and the maximum interstorey drift ratio (MISDR to express structural seismic response. Five different infill wall topologies of a 10-storey frame structure have been selected and analysed presenting an improved damage distribution model for infill wall bearing frames, hence promoting the use of nonstructural elements as a means of improving frame structural seismic behaviour and highlighting important aspects of structural response, demonstrating the suitability of such element implementation beyond their intended architectural scope.

  6. Predictive 3D search algorithm for multi-frame motion estimation

    NARCIS (Netherlands)

    Lim, Hong Yin; Kassim, A.A.; With, de P.H.N.

    2008-01-01

    Multi-frame motion estimation introduced in recent video standards such as H.264/AVC, helps to improve the rate-distortion performance and hence the video quality. This, however, comes at the expense of having a much higher computational complexity. In multi-frame motion estimation, there exists

  7. Dynamic frame selection for in vivo ultrasound temperature estimation during radiofrequency ablation

    International Nuclear Information System (INIS)

    Daniels, Matthew J; Varghese, Tomy

    2010-01-01

    Minimally invasive therapies such as radiofrequency ablation have been developed to treat cancers of the liver, prostate and kidney without invasive surgery. Prior work has demonstrated that ultrasound echo shifts due to temperature changes can be utilized to track the temperature distribution in real time. In this paper, a motion compensation algorithm is evaluated to reduce the impact of cardiac and respiratory motion on ultrasound-based temperature tracking methods. The algorithm dynamically selects the next suitable frame given a start frame (selected during the exhale or expiration phase where extraneous motion is reduced), enabling optimization of the computational time in addition to reducing displacement noise artifacts incurred with the estimation of smaller frame-to-frame displacements at the full frame rate. A region of interest that does not undergo ablation is selected in the first frame and the algorithm searches through subsequent frames to find a similarly located region of interest in subsequent frames, with a high value of the mean normalized cross-correlation coefficient value. In conjunction with dynamic frame selection, two different two-dimensional displacement estimation algorithms namely a block matching and multilevel cross-correlation are compared. The multi-level cross-correlation method incorporates tracking of the lateral tissue expansion in addition to the axial deformation to improve the estimation performance. Our results demonstrate the ability of the proposed motion compensation using dynamic frame selection in conjunction with the two-dimensional multilevel cross-correlation to track the temperature distribution.

  8. Evaluation of seismic reliability of steel moment resisting frames rehabilitated by concentric braces with probabilistic models

    Directory of Open Access Journals (Sweden)

    Fateme Rezaei

    2017-08-01

    Full Text Available Probability of structure failure which has been designed by "deterministic methods" can be more than the one which has been designed in similar situation using probabilistic methods and models considering "uncertainties". The main purpose of this research was to evaluate the seismic reliability of steel moment resisting frames rehabilitated with concentric braces by probabilistic models. To do so, three-story and nine-story steel moment resisting frames were designed based on resistant criteria of Iranian code and then they were rehabilitated based on controlling drift limitations by concentric braces. Probability of frames failure was evaluated by probabilistic models of magnitude, location of earthquake, ground shaking intensity in the area of the structure, probabilistic model of building response (based on maximum lateral roof displacement and probabilistic methods. These frames were analyzed under subcrustal source by sampling probabilistic method "Risk Tools" (RT. Comparing the exceedance probability of building response curves (or selected points on it of the three-story and nine-story model frames (before and after rehabilitation, seismic response of rehabilitated frames, was reduced and their reliability was improved. Also the main effective variables in reducing the probability of frames failure were determined using sensitivity analysis by FORM probabilistic method. The most effective variables reducing the probability of frames failure are  in the magnitude model, ground shaking intensity model error and magnitude model error

  9. Maximum entropy and Bayesian methods

    International Nuclear Information System (INIS)

    Smith, C.R.; Erickson, G.J.; Neudorfer, P.O.

    1992-01-01

    Bayesian probability theory and Maximum Entropy methods are at the core of a new view of scientific inference. These 'new' ideas, along with the revolution in computational methods afforded by modern computers allow astronomers, electrical engineers, image processors of any type, NMR chemists and physicists, and anyone at all who has to deal with incomplete and noisy data, to take advantage of methods that, in the past, have been applied only in some areas of theoretical physics. The title workshops have been the focus of a group of researchers from many different fields, and this diversity is evident in this book. There are tutorial and theoretical papers, and applications in a very wide variety of fields. Almost any instance of dealing with incomplete and noisy data can be usefully treated by these methods, and many areas of theoretical research are being enhanced by the thoughtful application of Bayes' theorem. Contributions contained in this volume present a state-of-the-art overview that will be influential and useful for many years to come

  10. Pole inflation in Jordan frame supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Saikawa, Ken' ichi [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Yamaguchi, Masahide [Tokyo Institute of Technology, Ookayama (Japan). Dept. of Physics; Yamashita, Yasuho [Kyoto Univ. (Japan). Yukawa Inst. for Theoretical Physics; Yoshida, Daisuke [Montreal Univ., QC (Canada). Dept. of Physics

    2017-09-15

    We investigate inflation models in Jordan frame supergravity, in which an inflaton non-minimally couples to the scalar curvature. By imposing the condition that an inflaton would have the canonical kinetic term in the Jordan frame, we construct inflation models with asymptotically flat potential through pole inflation technique and discuss their relation to the models based on Einstein frame supergravity. We also show that the model proposed by Ferrara et al. has special position and the relation between the Kaehler potential and the frame function is uniquely determined by requiring that scalars take the canonical kinetic terms in the Jordan frame and that a frame function consists only of a holomorphic term (and its anti-holomorphic counterpart) for symmetry breaking terms. Our case corresponds to relaxing the latter condition.

  11. Do framing effects reveal irrational choice?

    Science.gov (United States)

    Mandel, David R

    2014-06-01

    Framing effects have long been viewed as compelling evidence of irrationality in human decision making, yet that view rests on the questionable assumption that numeric quantifiers used to convey the expected values of choice options are uniformly interpreted as exact values. Two experiments show that when the exactness of such quantifiers is made explicit by the experimenter, framing effects vanish. However, when the same quantifiers are given a lower bound (at least) meaning, the typical framing effect is found. A 3rd experiment confirmed that most people spontaneously interpret the quantifiers in standard framing tests as lower bounded and that their interpretations strongly moderate the framing effect. Notably, in each experiment, a significant majority of participants made rational choices, either choosing the option that maximized expected value (i.e., lives saved) or choosing consistently across frames when the options were of equal expected value. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  12. Frames in the Ethiopian Debate on Biofuels

    Directory of Open Access Journals (Sweden)

    Brigitte Portner

    2013-01-01

    Full Text Available Biofuel production, while highly contested, is supported by a number of policies worldwide. Ethiopia was among the first sub-Saharan countries to devise a biofuel policy strategy to guide the associated demand toward sustainable development. In this paper, I discuss Ethiopia’s biofuel policy from an interpretative research position using a frames approach and argue that useful insights can be obtained by paying more attention to national contexts and values represented in the debates on whether biofuel production can or will contribute to sustainable development. To this end, I was able to distinguish three major frames used in the Ethiopian debate on biofuels: an environmental rehabilitation frame, a green revolution frame and a legitimacy frame. The article concludes that actors advocating for frames related to social and human issues have difficulties entering the debate and forming alliances, and that those voices need to be included in order for Ethiopia to develop a sustainable biofuel sector.

  13. Pole inflation in Jordan frame supergravity

    International Nuclear Information System (INIS)

    Saikawa, Ken'ichi; Yamaguchi, Masahide; Yamashita, Yasuho; Yoshida, Daisuke

    2017-09-01

    We investigate inflation models in Jordan frame supergravity, in which an inflaton non-minimally couples to the scalar curvature. By imposing the condition that an inflaton would have the canonical kinetic term in the Jordan frame, we construct inflation models with asymptotically flat potential through pole inflation technique and discuss their relation to the models based on Einstein frame supergravity. We also show that the model proposed by Ferrara et al. has special position and the relation between the Kaehler potential and the frame function is uniquely determined by requiring that scalars take the canonical kinetic terms in the Jordan frame and that a frame function consists only of a holomorphic term (and its anti-holomorphic counterpart) for symmetry breaking terms. Our case corresponds to relaxing the latter condition.

  14. The power and robustness of maximum LOD score statistics.

    Science.gov (United States)

    Yoo, Y J; Mendell, N R

    2008-07-01

    The maximum LOD score statistic is extremely powerful for gene mapping when calculated using the correct genetic parameter value. When the mode of genetic transmission is unknown, the maximum of the LOD scores obtained using several genetic parameter values is reported. This latter statistic requires higher critical value than the maximum LOD score statistic calculated from a single genetic parameter value. In this paper, we compare the power of maximum LOD scores based on three fixed sets of genetic parameter values with the power of the LOD score obtained after maximizing over the entire range of genetic parameter values. We simulate family data under nine generating models. For generating models with non-zero phenocopy rates, LOD scores maximized over the entire range of genetic parameters yielded greater power than maximum LOD scores for fixed sets of parameter values with zero phenocopy rates. No maximum LOD score was consistently more powerful than the others for generating models with a zero phenocopy rate. The power loss of the LOD score maximized over the entire range of genetic parameters, relative to the maximum LOD score calculated using the correct genetic parameter value, appeared to be robust to the generating models.

  15. Frame and Metaphor in Political Games

    OpenAIRE

    Bogost, Ian

    2005-01-01

    This paper offers an approach to analyzing political rhetoric in videogames, and on designing videogames intended to carry ideological bias, based cognitive linguist George Lakoff’s notion of metaphor and frame in political discourse. I argue for two important ways games function in relation to ideological frames, reinforcement and exposition, through examples of art games, political games, and commercial games. Finally, I argue that an explicit design of ideological frames in games is crucia...

  16. Economics and psychology. The framing of decisions

    OpenAIRE

    Schilirò, Daniele

    2016-01-01

    In the Theory of Rational Decision Making the psychological aspects are set aside. This contribution seeks to point out the relevance of psychology into economic decisions. The essay treats the "framing of decisions", which is a pillar of Kahneman's behavioral theory. Framing must be considered a special case of the more general phenomenon of dependency from the representation. The best-known risky choice-framing problem, i.e. the "Asian Disease Problem", is shown where an essential aspect of...

  17. Molecular frame and recoil frame angular distributions in dissociative photoionization of small molecules

    International Nuclear Information System (INIS)

    Lucchese, R R; Carey, R; Elkharrat, C; Houver, J C; Dowek, D

    2008-01-01

    Photoelectron angular distributions in the dipole approximation can be written with respect to several different reference frames. A brief review of the molecular frame and recoil frame are given. Experimentally, one approach for obtaining such angular distributions is through angle-resolved coincidence measurements of dissociative ionization. If the system dissociates into two heavy fragments, then the recoil frame angular distribution can be measured. Computed molecular frame and recoil frame photoelectron angular distributions are compared to experimental data for the Cl 2p ionization of CH 3 Cl.

  18. Journalism Curiosity and Story Telling Frame

    DEFF Research Database (Denmark)

    Grunwald, Ebbe; Rupar, Verica

    2009-01-01

    This comparative study of journalism practices in Australia and Denmark explores the interplay between two concepts relevant for journalism's meaning-making activity: a curiosity seen as an action meant to close an information gap, and a story telling frame seen as a form of structuring information...... the epistemological and organisational dimension of frames relates to the process of  meaning-making. We suggest refining the concept of frame in journalism studies by making a distinction between a frame (an epistemological category) and an angle (a textual organisation category). Our investigation shows...... that this distinction better serves the analysis and understanding of the mechanisms behind journalism in comparative contexts. Udgivelsesdato: December...

  19. Pilotless Frame Synchronization Using LDPC Code Constraints

    Science.gov (United States)

    Jones, Christopher; Vissasenor, John

    2009-01-01

    A method of pilotless frame synchronization has been devised for low- density parity-check (LDPC) codes. In pilotless frame synchronization , there are no pilot symbols; instead, the offset is estimated by ex ploiting selected aspects of the structure of the code. The advantag e of pilotless frame synchronization is that the bandwidth of the sig nal is reduced by an amount associated with elimination of the pilot symbols. The disadvantage is an increase in the amount of receiver data processing needed for frame synchronization.

  20. Frame sequences analysis technique of linear objects movement

    Science.gov (United States)

    Oshchepkova, V. Y.; Berg, I. A.; Shchepkin, D. V.; Kopylova, G. V.

    2017-12-01

    Obtaining data by noninvasive methods are often needed in many fields of science and engineering. This is achieved through video recording in various frame rate and light spectra. In doing so quantitative analysis of movement of the objects being studied becomes an important component of the research. This work discusses analysis of motion of linear objects on the two-dimensional plane. The complexity of this problem increases when the frame contains numerous objects whose images may overlap. This study uses a sequence containing 30 frames at the resolution of 62 × 62 pixels and frame rate of 2 Hz. It was required to determine the average velocity of objects motion. This velocity was found as an average velocity for 8-12 objects with the error of 15%. After processing dependencies of the average velocity vs. control parameters were found. The processing was performed in the software environment GMimPro with the subsequent approximation of the data obtained using the Hill equation.

  1. Maximum entropy principal for transportation

    International Nuclear Information System (INIS)

    Bilich, F.; Da Silva, R.

    2008-01-01

    In this work we deal with modeling of the transportation phenomenon for use in the transportation planning process and policy-impact studies. The model developed is based on the dependence concept, i.e., the notion that the probability of a trip starting at origin i is dependent on the probability of a trip ending at destination j given that the factors (such as travel time, cost, etc.) which affect travel between origin i and destination j assume some specific values. The derivation of the solution of the model employs the maximum entropy principle combining a priori multinomial distribution with a trip utility concept. This model is utilized to forecast trip distributions under a variety of policy changes and scenarios. The dependence coefficients are obtained from a regression equation where the functional form is derived based on conditional probability and perception of factors from experimental psychology. The dependence coefficients encode all the information that was previously encoded in the form of constraints. In addition, the dependence coefficients encode information that cannot be expressed in the form of constraints for practical reasons, namely, computational tractability. The equivalence between the standard formulation (i.e., objective function with constraints) and the dependence formulation (i.e., without constraints) is demonstrated. The parameters of the dependence-based trip-distribution model are estimated, and the model is also validated using commercial air travel data in the U.S. In addition, policy impact analyses (such as allowance of supersonic flights inside the U.S. and user surcharge at noise-impacted airports) on air travel are performed.

  2. Rotating frames in special relativity

    International Nuclear Information System (INIS)

    Strauss, M.

    1979-01-01

    The transformation theory for rotating frames presented in a previous paper is generalized by replacing the usual condition r = R for ωR < c (invariance of radius) by r = Rg(βsub(R)) so that r is now defined for all values of R, 0 <= R <= infinity. This generalization does not affect the kinematic transformation bracetheta, T → bracethetasup(r), bracesup(r) and the result group structure required by the theoretical constraints previously established, provided the old parameter 'r' (=R) is now identified throughout with either r or R; for physical reasons it must be identified with R. The function g, which cannot be fixed by theoretical constraints, determines the degree of geometrical anisotropy in the rotating plane z = const. More specifically, since g enters the expression for the ratio C/D (circumference/diameter) its choice corresponds to the choice of a congruence definition for lengths in radial and tangential directions. While on this (purely geometrical) level g remains undetermined, it can be uniquely determined experimentally on the kinematic level, e.g. by observing in Σsup(ω) the motion of a free particle. Thus the supremacy of kinematics over geometry is explicated by a further instance. At the same time, special relativity theory (SRT) is shown to belong to the class of theories with theoretically unsolvable problems. (author)

  3. Network-based H.264/AVC whole frame loss visibility model and frame dropping methods.

    Science.gov (United States)

    Chang, Yueh-Lun; Lin, Ting-Lan; Cosman, Pamela C

    2012-08-01

    We examine the visual effect of whole frame loss by different decoders. Whole frame losses are introduced in H.264/AVC compressed videos which are then decoded by two different decoders with different common concealment effects: frame copy and frame interpolation. The videos are seen by human observers who respond to each glitch they spot. We found that about 39% of whole frame losses of B frames are not observed by any of the subjects, and over 58% of the B frame losses are observed by 20% or fewer of the subjects. Using simple predictive features which can be calculated inside a network node with no access to the original video and no pixel level reconstruction of the frame, we developed models which can predict the visibility of whole B frame losses. The models are then used in a router to predict the visual impact of a frame loss and perform intelligent frame dropping to relieve network congestion. Dropping frames based on their visual scores proves superior to random dropping of B frames.

  4. Frame Filtering and Skipping for Point Cloud Data Video Transmission

    Directory of Open Access Journals (Sweden)

    Carlos Moreno

    2017-01-01

    Full Text Available Sensors for collecting 3D spatial data from the real world are becoming more important. They are a prime research area topic and have applications in consumer markets, such as medical, entertainment, and robotics. However, a primary concern with collecting this data is the vast amount of information being generated, and thus, needing to be processed before being transmitted. To address the issue, we propose the use of filtering methods and frame skipping. To collect the 3D spatial data, called point clouds, we used the Microsoft Kinect sensor. In addition, we utilized the Point Cloud Library to process and filter the data being generated by the Kinect. Two different computers were used: a client which collects, filters, and transmits the point clouds; and a server that receives and visualizes the point clouds. The client is also checking for similarity in consecutive frames, skipping those that reach a similarity threshold. In order to compare the filtering methods and test the effectiveness of the frame skipping technique, quality of service (QoS metrics such as frame rate and percentage of filter were introduced. These metrics indicate how well a certain combination of filtering method and frame skipping accomplishes the goal of transmitting point clouds from one location to another. We found that the pass through filter in conjunction with frame skipping provides the best relative QoS. However, results also show that there is still too much data for a satisfactory QoS. For a real-time system to provide reasonable end-to-end quality, dynamic compression and progressive transmission need to be utilized.

  5. Effective or ineffective: attribute framing and the human papillomavirus (HPV) vaccine.

    Science.gov (United States)

    Bigman, Cabral A; Cappella, Joseph N; Hornik, Robert C

    2010-12-01

    To experimentally test whether presenting logically equivalent, but differently valenced effectiveness information (i.e. attribute framing) affects perceived effectiveness of the human papillomavirus (HPV) vaccine, vaccine-related intentions and policy opinions. A survey-based experiment (N=334) was fielded in August and September 2007 as part of a larger ongoing web-enabled monthly survey, the Annenberg National Health Communication Survey. Participants were randomly assigned to read a short passage about the HPV vaccine that framed vaccine effectiveness information in one of five ways. Afterward, they rated the vaccine and related opinion questions. Main statistical methods included ANOVA and t-tests. On average, respondents exposed to positive framing (70% effective) rated the HPV vaccine as more effective and were more supportive of vaccine mandate policy than those exposed to the negative frame (30% ineffective) or the control frame. Mixed valence frames showed some evidence for order effects; phrasing that ended by emphasizing vaccine ineffectiveness showed similar vaccine ratings to the negative frame. The experiment finds that logically equivalent information about vaccine effectiveness not only influences perceived effectiveness, but can in some cases influence support for policies mandating vaccine use. These framing effects should be considered when designing messages. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  6. Effective or ineffective: Attribute framing and the human papillomavirus (HPV) vaccine

    Science.gov (United States)

    Bigman, Cabral A.; Cappella, Joseph N.; Hornik, Robert C.

    2010-01-01

    Objectives To experimentally test whether presenting logically equivalent, but differently valenced effectiveness information (i.e. attribute framing) affects perceived effectiveness of the human papillomavirus (HPV) vaccine, vaccine related intentions and policy opinions. Method A survey-based experiment (N= 334) was fielded in August and September 2007 as part of a larger ongoing web-enabled monthly survey, the Annenberg National Health Communication Survey. Participants were randomly assigned to read a short passage about the HPV vaccine that framed vaccine effectiveness information in one of five ways. Afterward, they rated the vaccine and related opinion questions. Main statistical methods included ANOVA and t-tests. Results On average, respondents exposed to positive framing (70% effective) rated the HPV vaccine as more effective and were more supportive of vaccine mandate policy than those exposed to the negative frame (30% ineffective) or the control frame. Mixed valence frames showed some evidence for order effects; phrasing that ended by emphasizing vaccine ineffectiveness showed similar vaccine ratings to the negative frame. Conclusions The experiment finds that logically equivalent information about vaccine effectiveness not only influences perceived effectiveness, but can in some cases influence support for policies mandating vaccine use. Practice implications These framing effects should be considered when designing messages. PMID:20851560

  7. Last Glacial Maximum Salinity Reconstruction

    Science.gov (United States)

    Homola, K.; Spivack, A. J.

    2016-12-01

    It has been previously demonstrated that salinity can be reconstructed from sediment porewater. The goal of our study is to reconstruct high precision salinity during the Last Glacial Maximum (LGM). Salinity is usually determined at high precision via conductivity, which requires a larger volume of water than can be extracted from a sediment core, or via chloride titration, which yields lower than ideal precision. It has been demonstrated for water column samples that high precision density measurements can be used to determine salinity at the precision of a conductivity measurement using the equation of state of seawater. However, water column seawater has a relatively constant composition, in contrast to porewater, where variations from standard seawater composition occur. These deviations, which affect the equation of state, must be corrected for through precise measurements of each ion's concentration and knowledge of apparent partial molar density in seawater. We have developed a density-based method for determining porewater salinity that requires only 5 mL of sample, achieving density precisions of 10-6 g/mL. We have applied this method to porewater samples extracted from long cores collected along a N-S transect across the western North Atlantic (R/V Knorr cruise KN223). Density was determined to a precision of 2.3x10-6 g/mL, which translates to salinity uncertainty of 0.002 gms/kg if the effect of differences in composition is well constrained. Concentrations of anions (Cl-, and SO4-2) and cations (Na+, Mg+, Ca+2, and K+) were measured. To correct salinities at the precision required to unravel LGM Meridional Overturning Circulation, our ion precisions must be better than 0.1% for SO4-/Cl- and Mg+/Na+, and 0.4% for Ca+/Na+, and K+/Na+. Alkalinity, pH and Dissolved Inorganic Carbon of the porewater were determined to precisions better than 4% when ratioed to Cl-, and used to calculate HCO3-, and CO3-2. Apparent partial molar densities in seawater were

  8. Maximum Parsimony on Phylogenetic networks

    Science.gov (United States)

    2012-01-01

    Background Phylogenetic networks are generalizations of phylogenetic trees, that are used to model evolutionary events in various contexts. Several different methods and criteria have been introduced for reconstructing phylogenetic trees. Maximum Parsimony is a character-based approach that infers a phylogenetic tree by minimizing the total number of evolutionary steps required to explain a given set of data assigned on the leaves. Exact solutions for optimizing parsimony scores on phylogenetic trees have been introduced in the past. Results In this paper, we define the parsimony score on networks as the sum of the substitution costs along all the edges of the network; and show that certain well-known algorithms that calculate the optimum parsimony score on trees, such as Sankoff and Fitch algorithms extend naturally for networks, barring conflicting assignments at the reticulate vertices. We provide heuristics for finding the optimum parsimony scores on networks. Our algorithms can be applied for any cost matrix that may contain unequal substitution costs of transforming between different characters along different edges of the network. We analyzed this for experimental data on 10 leaves or fewer with at most 2 reticulations and found that for almost all networks, the bounds returned by the heuristics matched with the exhaustively determined optimum parsimony scores. Conclusion The parsimony score we define here does not directly reflect the cost of the best tree in the network that displays the evolution of the character. However, when searching for the most parsimonious network that describes a collection of characters, it becomes necessary to add additional cost considerations to prefer simpler structures, such as trees over networks. The parsimony score on a network that we describe here takes into account the substitution costs along the additional edges incident on each reticulate vertex, in addition to the substitution costs along the other edges which are

  9. A note on the standard dual frame of a wavelet frame with three-scale

    International Nuclear Information System (INIS)

    Chen Qingjiang; Wei Zongtian; Feng Jinshun

    2009-01-01

    In this paper, it is shown that there exist wavelet frames generated by two functions which have good dual wavelet frames, but for which the standard dual wavelet frame does not consist of wavelets. That is to say, the standard dual wavelet frame cannot be generated by the translations and dilations of a single function. Relation to some physical theories such as entropy and E-infinity theory is also discussed.

  10. When message-frame fits salient cultural-frame, messages feel more persuasive

    OpenAIRE

    Uskul, Ayse K.; Oyserman, Daphna

    2010-01-01

    The present study examines the persuasive effects of tailored health messages comparing those tailored to match (versus not match) both chronic cultural frame and momentarily salient cultural frame. Evidence from two studies (Study 1: n = 72 European Americans; Study 2: n = 48 Asian Americans) supports the hypothesis that message persuasiveness increases when chronic cultural frame, health message tailoring and momentarily salient cultural frame all match. The hypothesis was tested using a me...

  11. News Framing in a Time of Terror

    DEFF Research Database (Denmark)

    Jørndrup, Hanne

    2016-01-01

    the attacks at the Charlie Hebdo office in Paris in January 2015. This article analyses how the Danish television channel DR1 framed the attacks in the newscast from the first shot at Krudttønden and for the following week. Furthermore, the analysis will discuss how the framing of the shooting as a “terror...

  12. Framing effect debiasing in medical decision making.

    Science.gov (United States)

    Almashat, Sammy; Ayotte, Brian; Edelstein, Barry; Margrett, Jennifer

    2008-04-01

    Numerous studies have demonstrated the robustness of the framing effect in a variety of contexts. The present study investigated the effects of a debiasing procedure designed to prevent the framing effect for young adults who made decisions based on hypothetical medical decision-making vignettes. The debiasing technique involved participants listing advantages and disadvantages of each treatment prior to making a choice. One hundred and two undergraduate students read a set of three medical treatment vignettes that presented information in terms of different outcome probabilities under either debiasing or control conditions. The framing effect was demonstrated by the control group in two of the three vignettes. The debiasing group successfully avoided the framing effect for both of these vignettes. These results further support previous findings of the framing effect as well as an effective debiasing technique. This study improved upon previous framing debiasing studies by including a control group and personal medical scenarios, as well as demonstrating debiasing in a framing condition in which the framing effect was demonstrated without a debiasing procedure. The findings suggest a relatively simple manipulation may circumvent the use of decision-making heuristics in patients.

  13. Sustainable food and agriculture: stakeholder's frames

    NARCIS (Netherlands)

    van Gorp, B.; van der Goot, M.J.

    2012-01-01

    Despite its importance, the notion of sustainability is open for discursive struggle. This article's primary objective is to acquire insight into the manner in which the principal stakeholders strategically use frames in their public communication about sustainable food and agriculture. A framing

  14. Teaching the Dynamics of Framing Competitions

    Science.gov (United States)

    Rinke, Eike Mark

    2012-01-01

    Framing theory is one of the most thriving and complex fields of communication theory, and as such it has grown to be an integral part of many political communication, public opinion, and communication theory courses. Part of the complexity stems from scholars' efforts to develop accounts of framing processes that are closer to the "real world" of…

  15. Framing Behaviours in Novice Interaction Designers

    Science.gov (United States)

    Lotz, Nicole; Sharp, Helen; Woodroffe, Mark; Blyth, Richard; Rajah, Dino; Ranganai, Turugare

    2015-01-01

    Framing design problems and solutions has been recognised in design studies as a central designerly activity. Some recent findings with expert designers relate framing practices to problem-solution co-evolution and analogy use, two further widely recognised design strategies. We wanted to understand if interaction design novices also use…

  16. A Framing Primer for Community College Leaders

    Science.gov (United States)

    Nausieda, Ryan

    2014-01-01

    The purpose of this article is to be a tool for community college leaders, as well as campus members, to positively and effectively utilize framing on their campuses. The fictional case of Maggie Pascal at Midwestern Community College illustrates the process of framing the change of a new partnership with Wind Energy Corporation to internal…

  17. Effect of framing on adolescents' decision making.

    Science.gov (United States)

    Chien, Y C; Lin, C; Worthley, J

    1996-12-01

    92 young adolescents were tested using Tversky and Kahneman's (1981) decision problems for framing effects. A notable number of young adolescents tested were not influenced by the context of the decision problems, thus they selected the same response option for positively and negatively framed problems. Parallel information was not available in Tversky and Kahneman's study for adults because they used a between-subjects design. However, for present adolescents who selected different response options for different framing problems, the response pattern exhibited by them resembled the general pattern exhibited by the adults tested in Tversky and Kahneman's study-negative frames led them to accept risk to avoid certain loss; positive frames prevented them from risking what they were certain to gain. Boys and girls were similar in their susceptibility to framing effects as were honors students in mathematics as compared to nonhonors students. Although the positive vs negative framing only influenced some of the young adolescents tested in this study, because the influence was consistent, researchers and educators interested in adolescents' decisions involving risky choices might use framing principles to design and assess cognitive interventions for high-risk behaviors among young adolescents.

  18. Hydraulic Limits on Maximum Plant Transpiration

    Science.gov (United States)

    Manzoni, S.; Vico, G.; Katul, G. G.; Palmroth, S.; Jackson, R. B.; Porporato, A. M.

    2011-12-01

    Photosynthesis occurs at the expense of water losses through transpiration. As a consequence of this basic carbon-water interaction at the leaf level, plant growth and ecosystem carbon exchanges are tightly coupled to transpiration. In this contribution, the hydraulic constraints that limit transpiration rates under well-watered conditions are examined across plant functional types and climates. The potential water flow through plants is proportional to both xylem hydraulic conductivity (which depends on plant carbon economy) and the difference in water potential between the soil and the atmosphere (the driving force that pulls water from the soil). Differently from previous works, we study how this potential flux changes with the amplitude of the driving force (i.e., we focus on xylem properties and not on stomatal regulation). Xylem hydraulic conductivity decreases as the driving force increases due to cavitation of the tissues. As a result of this negative feedback, more negative leaf (and xylem) water potentials would provide a stronger driving force for water transport, while at the same time limiting xylem hydraulic conductivity due to cavitation. Here, the leaf water potential value that allows an optimum balance between driving force and xylem conductivity is quantified, thus defining the maximum transpiration rate that can be sustained by the soil-to-leaf hydraulic system. To apply the proposed framework at the global scale, a novel database of xylem conductivity and cavitation vulnerability across plant types and biomes is developed. Conductivity and water potential at 50% cavitation are shown to be complementary (in particular between angiosperms and conifers), suggesting a tradeoff between transport efficiency and hydraulic safety. Plants from warmer and drier biomes tend to achieve larger maximum transpiration than plants growing in environments with lower atmospheric water demand. The predicted maximum transpiration and the corresponding leaf water

  19. Parametric Study Of Window Frame Geometry

    DEFF Research Database (Denmark)

    Zajas, Jan Jakub; Heiselberg, Per

    2013-01-01

    This paper describes a parametric study on window frame geometry with the goal of designing frames with very good thermal properties. Three different parametric frame models are introduced, deseribed by a number of variables. In the first part of the study, a process of sensitivity analysis...... is conducted to determine which of the parameters describing the frame have the highest impact on its thermal performance. Afterwards, an optimization process is conducted on each frame in order to optimize the design with regard to three objectives: minimizing the thermal transmittance, maxim izing the net...... energy gain factor and minimizing the material use. Since the objectives contradiet each other, it was found that it is not possible to identifY a single solution that satisfies all these goals. lnstead, a compromise between the objectives has to be found....

  20. An introduction to frames and Riesz bases

    CERN Document Server

    Christensen, Ole

    2016-01-01

    This revised and expanded monograph presents the general theory for frames and Riesz bases in Hilbert spaces as well as its concrete realizations within Gabor analysis, wavelet analysis, and generalized shift-invariant systems.  Compared with the first edition, more emphasis is put on explicit constructions with attractive properties.  Based on the exiting development of frame theory over the last decade, this second edition now includes new sections on the rapidly growing fields of LCA groups, generalized shift-invariant systems, duality theory for as well Gabor frames as wavelet frames, and open problems in the field.   Key features include: *Elementary introduction to frame theory in finite-dimensional spaces * Basic results presented in an accessible way for both pure and applied mathematicians * Extensive exercises make the work suitable as a textbook for use in graduate courses * Full proofs includ ed in introductory chapters; only basic knowledge of functional analysis required * Explicit constructi...