WorldWideScience

Sample records for maximum doses tolerated

  1. Maximum tolerable radiation doses recommended by the Israel Advisory Committee on nuclear safety

    International Nuclear Information System (INIS)

    Tadmor, J.; Litai, D.; Lubin, E.

    1978-01-01

    Maximum tolerable doses have been recommended by the Israel Advisory Committee on Nuclear Safety. The recommendations which are based on a comparison with risks tolerated in other human activities, are for doses to radiation workers, for individual members of the population at the fence of a nuclear installation, and for the population at large, for both normal operating and accident conditions. Tolerable whole-body doses and doses to different critical organs are listed

  2. Benefits of the maximum tolerated dose (MTD) and maximum tolerated concentration (MTC) concept in aquatic toxicology

    International Nuclear Information System (INIS)

    Hutchinson, Thomas H.; Boegi, Christian; Winter, Matthew J.; Owens, J. Willie

    2009-01-01

    There is increasing recognition of the need to identify specific sublethal effects of chemicals, such as reproductive toxicity, and specific modes of actions of the chemicals, such as interference with the endocrine system. To achieve these aims requires criteria which provide a basis to interpret study findings so as to separate these specific toxicities and modes of action from not only acute lethality per se but also from severe inanition and malaise that non-specifically compromise reproductive capacity and the response of endocrine endpoints. Mammalian toxicologists have recognized that very high dose levels are sometimes required to elicit both specific adverse effects and present the potential of non-specific 'systemic toxicity'. Mammalian toxicologists have developed the concept of a maximum tolerated dose (MTD) beyond which a specific toxicity or action cannot be attributed to a test substance due to the compromised state of the organism. Ecotoxicologists are now confronted by a similar challenge and must develop an analogous concept of a MTD and the respective criteria. As examples of this conundrum, we note recent developments in efforts to validate protocols for fish reproductive toxicity and endocrine screens (e.g. some chemicals originally selected as 'negatives' elicited decreases in fecundity or changes in endpoints intended to be biomarkers for endocrine modes of action). Unless analogous criteria can be developed, the potentially confounding effects of systemic toxicity may then undermine the reliable assessment of specific reproductive effects or biomarkers such as vitellogenin or spiggin. The same issue confronts other areas of aquatic toxicology (e.g., genotoxicity) and the use of aquatic animals for preclinical assessments of drugs (e.g., use of zebrafish for drug safety assessment). We propose that there are benefits to adopting the concept of an MTD for toxicology and pharmacology studies using fish and other aquatic organisms and the

  3. Maximum tolerated dose in a phase I trial on adaptive dose painting by numbers for head and neck cancer

    International Nuclear Information System (INIS)

    Madani, Indira; Duprez, Fréderic; Boterberg, Tom; Van de Wiele, Christophe; Bonte, Katrien; Deron, Philippe; De Gersem, Werner; Coghe, Marc; De Neve, Wilfried

    2011-01-01

    Purpose: To determine the maximum tolerated dose (MTD) in a phase I trial on adaptive dose-painting-by-numbers (DPBN) for non-metastatic head and neck cancer. Materials and methods: Adaptive intensity-modulated radiotherapy was based on voxel intensity of pre-treatment and per-treatment [ 18 F]fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG-PET) scans. Dose was escalated to a median total dose of 80.9 Gy in the high-dose clinical target volume (dose level I) and 85.9 Gy in the gross tumor volume (dose level II). The MTD would be reached, if ⩾33% of patients developed any grade ⩾4 toxicity (DLT) up to 3 months follow-up. Results: Between February 2007 and August 2009, seven patients at dose level I and 14 at dose level II were treated. All patients completed treatment without interruption. At a median follow-up for surviving patients of 38 (dose level I) and 22 months (dose level II) there was no grade ⩾4 toxicity during treatment and follow-up but six cases of mucosal ulcers at latency of 4–10 months, of which five (36%) were observed at dose level II. Mucosal ulcers healed spontaneously in four patients. Conclusions: Considering late mucosal ulcers as DLT, the MTD of a median dose of 80.9 Gy has been reached in our trial.

  4. Tolerance of the human spinal cord to single dose radiosurgery

    International Nuclear Information System (INIS)

    Ryu, S.; Zhu, G.; Yin, F.-F.; Ajlouni, M.; Kim, J.H.

    2003-01-01

    Tolerance of the spinal cord to the single dose of radiation is not well defined. Although there are cases of human spinal cord tolerance from re-irradiation to the same cord level, the information about the tolerance of human spinal cord to single large dose of radiosurgery is not available. We carried out spinal radiosurgery to treat spinal metastasis and studied the single dose tolerance of the human spinal cord in an ongoing dose escalation paradigm. A total of 39 patients with 48 lesions of spinal metastasis were treated with single dose radiosurgery at Henry Ford Hospital. The radiosurgery dose was escalated from 8 Gy to 16 Gy at 2 Gy increment. The radiation dose was prescribed to periphery of the spinal tumor. The radiation dose to the spinal cord was estimated by computerized dosimetry. The median follow-up time was 10 months (range 6-18 months) from the radiosurgery. The endpoint of the study was to demonstrate the efficacy of the spinal radiosurgery and to determine the tolerance of human spinal cord to single dose radiosurgery. The dose to the spinal cord was generally less than 50 % of the prescribed radiation dose. The volume of the spinal cord that received higher than this dose was less than 20 % of the anterior portion of the spinal cord. Maximum single dose of 8 Gy was delivered to the anterior 20 % of the spinal cord in this dose escalation study. The dose volume histogram will be presented. There was no acute or subacute radiation toxicity detected clinically and radiologically during the maximum follow-up of 20 months. Further dose escalation is in progress. The single tolerance dose of the human spinal cord appears to be at least 8 Gy when it was given to the 20 % of the cord volume, although the duration of follow up is not long enough to detect severe late cord toxicity. This study offers a valuable radiobiological basis of the normal spinal cord tolerance, and opens spinal radiosurgery as a safe treatment for spinal metastasis

  5. Maximum tolerated dose evaluation of the AMPA modulator Org 26576 in healthy volunteers and depressed patients: a summary and method analysis of bridging research in support of phase II dose selection.

    Science.gov (United States)

    Nations, Kari R; Bursi, Roberta; Dogterom, Peter; Ereshefsky, Larry; Gertsik, Lev; Mant, Tim; Schipper, Jacques

    2012-09-01

    A key challenge to dose selection in early central nervous system (CNS) clinical drug development is that patient tolerability profiles often differ from those of healthy volunteers (HVs), yet HVs are the modal population for determining doses to be investigated in phase II trials. Without clear tolerability data from the target patient population, first efficacy trials may include doses that are either too high or too low, creating undue risk for study participants and the development program overall. Bridging trials address this challenge by carefully investigating safety and tolerability in the target population prior to full-scale proof-of-concept trials. Org 26576 is an alpha-amino-3-hydroxy-5-methylisoxazole-4-propionic acid (AMPA) receptor positive allosteric modulator that acts by modulating ionotropic AMPA-type glutamate receptors to enhance glutamatergic neurotransmission. In preparation for phase II efficacy trials in major depressive disorder (MDD), two separate phase I trials were conducted to evaluate safety, tolerability, and pharmacokinetics in HVs and in the target patient population. Both trials were randomized and placebo controlled, and included multiple rising-dose cohorts (HV range 100-400 mg bid; MDD range 100-600 mg bid). HVs (n = 36) and patients with MDD (n = 54) were dosed under similarly controlled conditions in an inpatient facility, HVs for up to 14 days and MDD patients for up to 28 days. Safety, tolerability, and pharmacokinetics were assessed frequently. Despite comparable pharmacokinetic profiles, the maximum tolerated dose (MTD) in depressed patients was 450 mg bid, twice the MTD established in HVs. No clinically relevant safety issues associated with Org 26576 were noted. This article presents safety, tolerability, and pharmacokinetic data from two different populations examined under similar dosing conditions. The important implications of such bridging work in phase II dose selection are discussed, as are study

  6. An overview of the report: Correlation between carcinogenic potency and the maximum tolerated dose: Implications for risk assessment

    International Nuclear Information System (INIS)

    Krewski, D.; Gaylor, D.W.; Soms, A.P.; Szyszkowicz, M.

    1993-01-01

    Current practice in carcinogen bioassay calls for exposure of experimental animals at doses up to and including the maximum tolerated dose (MTD). Such studies have been used to compute measures of carcinogenic potency such as the TD 50 as well as unit risk factors such as q 1 for predicting low-dose risks. Recent studies have indicated that these measures of carcinogenic potency are highly correlated with the MTD. Carcinogenic potency has also been shown to be correlated with indicators of mutagenicity and toxicity. Correlation of the MTDs for rats and mice implies a corresponding correlation in TD 50 values for these two species. The implications of these results for cancer risk assessment are examined in light of the large variation in potency among chemicals known to induce tumors in rodents. 119 refs., 2 figs., 4 tabs

  7. Some thoughts on tolerance, dose, and fractionation in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gahbauer, R.; Goodman, J.; Blue, T.

    1988-01-01

    Unique to boron neutron capture therapy, the tolerance very strongly depends on the boron concentration in normal brain, skin and blood. If one first considers the ideal situation of a 2 KeV beam and a compound clearing from normal tissues and blood, the tolerance dose to epithermal beams relates to the maximum tolerated capture gamma dose and capture high LET dose, H (n,gamma)D and N(n,p) 14 C. The authors can relate this gamma and high LET dose to known clinical experience. Assuming gamma and high LET dose ratios as given by Fairchild and Bond, one may first choose a clearly safe high LET whole brain dose and calculate the unavoidably resulting gamma dose. To a first approximation 500 cGy of high LET dose results in 3,000 cGy gamma dose. One can speculate that this approximates the tolerance of whole brain to the 2 KeV beam with no contributing boron dose if the radiation is fractionated. It would clearly be beyond tolerance in a single fraction where most therapists would be uncomfortable to deliver even one third of the above doses

  8. Maximum permissible dose

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This chapter presents a historic overview of the establishment of radiation guidelines by various national and international agencies. The use of maximum permissible dose and maximum permissible body burden limits to derive working standards is discussed

  9. Regulatory Forum Opinion Piece*: Retrospective Evaluation of Doses in the 26-week Tg.rasH2 Mice Carcinogenicity Studies: Recommendation to Eliminate High Doses at Maximum Tolerated Dose in Future Studies. A Response to the Counterpoints.

    Science.gov (United States)

    Paranjpe, Madhav G; Denton, Melissa D; Vidmar, Tom J; Elbekai, Reem H

    2016-01-01

    We recently conducted a retrospective analysis of data collected from 29 Tg.rasH2 carcinogenicity studies conducted at our facility to determine how successful was the strategy of choosing the high dose of the 26-week studies based on an estimated maximum tolerated dose (MTD). As a result of our publication, 2 counterviews were expressed. Both counterviews illustrate very valid points in their interpretation of our data. In this article, we would like to highlight clarifications based on several points and issues they have raised in their papers, namely, the dose-level selection, determining if MTD was exceeded in 26-week studies, and a discussion on the number of dose groups to be used in the studies. © The Author(s) 2015.

  10. Regulatory Forum Opinion Piece*: Retrospective Evaluation of Doses in the 26-week Tg.rasH2 Mice Carcinogenicity Studies: Recommendation to Eliminate High Doses at Maximum Tolerated Dose (MTD) in Future Studies.

    Science.gov (United States)

    Paranjpe, Madhav G; Denton, Melissa D; Vidmar, Tom J; Elbekai, Reem H

    2015-07-01

    High doses in Tg.rasH2 carcinogenicity studies are usually set at the maximum tolerated dose (MTD), although this dose selection strategy has not been critically evaluated. We analyzed the body weight gains (BWGs), mortality, and tumor response in control and treated groups of 29 Tg.rasH2 studies conducted at BioReliance. Based on our analysis, it is evident that the MTD was exceeded at the high and/or mid-doses in several studies. The incidence of tumors in high doses was lower when compared to the low and mid-doses of both sexes. Thus, we recommend that the high dose in male mice should not exceed one-half of the estimated MTD (EMTD), as it is currently chosen, and the next dose should be one-fourth of the EMTD. Because females were less sensitive to decrements in BWG, the high dose in female mice should not exceed two-third of EMTD and the next dose group should be one-third of EMTD. If needed, a third dose group should be set at one-eighth EMTD in males and one-sixth EMTD in females. In addition, for compounds that do not show toxicity in the range finding studies, a limit dose should be applied for the 26-week carcinogenicity studies. © 2014 by The Author(s).

  11. The irradiation tolerance dose of the proximal vagina

    International Nuclear Information System (INIS)

    Au, Samuel P.; Grigsby, Perry W.

    2003-01-01

    Purpose: The purpose of this investigation was to determine the irradiation tolerance level and complication rates of the proximal vagina to combined external irradiation and low dose rate (LDR) brachytherapy. Also, the mucosal tolerance for fractionated high dose rate (HDR) brachytherapy is further projected based on the biological equivalent dose (BED) of LDR for an acceptable complication rate. Materials and methods: Two hundred seventy-four patients with stages I-IV cervical carcinoma treated with irradiation therapy alone from 1987 to 1997 were retrospectively reviewed for radiation-associated late sequelae of the proximal vagina. All patients received LDR brachytherapy and 95% also received external pelvic irradiation. Follow-up ranged from 15 to 126 months (median, 43 months). The proximal vagina mucosa dose from a single ovoid (single source) or from both ovoids plus the tandem (all sources), together with the external irradiation dose, were used to derive the probability of a complication using the maximum likelihood logistic regression technique. The BED based on the linear-quadratic model was used to compute the corresponding tolerance levels for LDR or HDR brachytherapy. Results: Grades 1 and 2 complications occurred in 10.6% of patients and Grade 3 complications occurred in 3.6%. There were no Grade 4 complications. Complications occurred from 3 to 71 months (median, 7 months) after completion of irradiation, with over 60% occurring in the first year. By logistic regression analysis, both the mucosal dose from a single ovoid or that from all sources, combined with the external irradiation dose, demonstrate a statistically significant fit to the dose response complication curves (both with P=0.016). The single source dose was highly correlated with the all source dose with a cross-correlation coefficient 0.93. The all source dose was approximately 1.4 times the single source dose. Over the LDR brachytherapy dose rate range, the complication rate was

  12. Maximum concentrations at work and maximum biologically tolerable concentration for working materials 1991

    International Nuclear Information System (INIS)

    1991-01-01

    The meaning of the term 'maximum concentration at work' in regard of various pollutants is discussed. Specifically, a number of dusts and smokes are dealt with. The valuation criteria for maximum biologically tolerable concentrations for working materials are indicated. The working materials in question are corcinogeneous substances or substances liable to cause allergies or mutate the genome. (VT) [de

  13. Consideration of the volume dependence of tolerance doses

    International Nuclear Information System (INIS)

    Gremmel, H.; Wendhausen, H.

    1977-01-01

    A general formula for consideration of the dependence of tolerance doses upon volume is obtained by mathematical evaluation of known skin tolerance doses. The validity for different organs is verified using available data of literature. It is recommended to introduce the volume dependence into the Ellis-formula for tolerance doses. (orig.) [de

  14. Safety and maximum tolerated dose of superselective intraarterial cerebral infusion of bevacizumab after osmotic blood-brain barrier disruption for recurrent malignant glioma. Clinical article.

    Science.gov (United States)

    Boockvar, John A; Tsiouris, Apostolos J; Hofstetter, Christoph P; Kovanlikaya, Ilhami; Fralin, Sherese; Kesavabhotla, Kartik; Seedial, Stephen M; Pannullo, Susan C; Schwartz, Theodore H; Stieg, Philip; Zimmerman, Robert D; Knopman, Jared; Scheff, Ronald J; Christos, Paul; Vallabhajosula, Shankar; Riina, Howard A

    2011-03-01

    The authors assessed the safety and maximum tolerated dose of superselective intraarterial cerebral infusion (SIACI) of bevacizumab after osmotic disruption of the blood-brain barrier (BBB) with mannitol in patients with recurrent malignant glioma. A total of 30 patients with recurrent malignant glioma were included in the current study. The authors report no dose-limiting toxicity from a single dose of SIACI of bevacizumab up to 15 mg/kg after osmotic BBB disruption with mannitol. Two groups of patients were studied; those without prior bevacizumab exposure (naïve patients; Group I) and those who had received previous intravenous bevacizumab (exposed patients; Group II). Radiographic changes demonstrated on MR imaging were assessed at 1 month postprocedure. In Group I patients, MR imaging at 1 month showed a median reduction in the area of tumor enhancement of 34.7%, a median reduction in the volume of tumor enhancement of 46.9%, a median MR perfusion (MRP) reduction of 32.14%, and a T2-weighted/FLAIR signal decrease in 9 (47.4%) of 19 patients. In Group II patients, MR imaging at 1 month showed a median reduction in the area of tumor enhancement of 15.2%, a median volume reduction of 8.3%, a median MRP reduction of 25.5%, and a T2-weighted FLAIR decrease in 0 (0%) of 11 patients. The authors conclude that SIACI of mannitol followed by bevacizumab (up to 15 mg/kg) for recurrent malignant glioma is safe and well tolerated. Magnetic resonance imaging shows that SIACI treatment with bevacizumab can lead to reduction in tumor area, volume, perfusion, and T2-weighted/FLAIR signal.

  15. Tolerance of the Brachial Plexus to High-Dose Reirradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Allen M., E-mail: achen5@kumc.edu; Yoshizaki, Taeko; Velez, Maria A.; Mikaeilian, Argin G.; Hsu, Sophia; Cao, Minsong

    2017-05-01

    Purpose: To study the tolerance of the brachial plexus to high doses of radiation exceeding historically accepted limits by analyzing human subjects treated with reirradiation for recurrent tumors of the head and neck. Methods and Materials: Data from 43 patients who were confirmed to have received overlapping dose to the brachial plexus after review of radiation treatment plans from the initial and reirradiation courses were used to model the tolerance of this normal tissue structure. A standardized instrument for symptoms of neuropathy believed to be related to brachial plexus injury was utilized to screen for toxicity. Cumulative dose was calculated by fusing the initial dose distributions onto the reirradiation plan, thereby creating a composite plan via deformable image registration. The median elapsed time from the initial course of radiation therapy to reirradiation was 24 months (range, 3-144 months). Results: The dominant complaints among patients with symptoms were ipsilateral pain (54%), numbness/tingling (31%), and motor weakness and/or difficulty with manual dexterity (15%). The cumulative maximum dose (Dmax) received by the brachial plexus ranged from 60.5 Gy to 150.1 Gy (median, 95.0 Gy). The cumulative mean (Dmean) dose ranged from 20.2 Gy to 111.5 Gy (median, 63.8 Gy). The 1-year freedom from brachial plexus–related neuropathy was 67% and 86% for subjects with a cumulative Dmax greater than and less than 95.0 Gy, respectively (P=.05). The 1-year complication-free rate was 66% and 87%, for those reirradiated within and after 2 years from the initial course, respectively (P=.06). Conclusion: The development of brachial plexus–related symptoms was less than expected owing to repair kinetics and to the relatively short survival of the subject population. Time-dose factors were demonstrated to be predictive of complications.

  16. A study to evaluate safety and tolerability of repeated doses of tirasemtiv in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Shefner, Jeremy M; Watson, Mary Lou; Meng, Lisa; Wolff, Andrew A

    2013-12-01

    Abstract Tirasemtiv is a fast skeletal muscle activator that increases the sensitivity of the sarcomere to calcium, increasing the efficiency of muscle contraction when the muscle is stimulated at submaximal contraction frequencies. A previous study showed single doses of tirasemtiv to be well tolerated and associated with potentially important improvements in a variety of functional outcomes. This study determined safety of tirasemtiv when given at doses up to 500 mg daily for three weeks. Tirasemtiv was given as a single daily dose up to 375 mg for two weeks, with and without concomitant riluzole. In a separate cohort, an ascending dose protocol evaluated a total dose of 500 mg daily given in two divided doses. Safety and tolerability were assessed, as well as measures of function, muscle strength and endurance. Results showed that tirasemtiv was well tolerated, with dizziness the most common adverse event. Tirasemtiv approximately doubled the serum concentration of riluzole. Trends were noted for improvement in ALSFRS-R, Maximum Minute Ventilation, and Nasal Inspiratory Pressure. In conclusion, tirasemtiv is well tolerated and can be given safely with a reduced dose of riluzole. Positive trends in multiple exploratory outcome measures support the further study of this agent in ALS.

  17. Radiation therapy tolerance doses for treatment planning

    International Nuclear Information System (INIS)

    Lyman, J.T.

    1987-01-01

    To adequately plan acceptable dose distributions for radiation therapy treatments it is necessary to ensure that normal structures do not receive unacceptable doses. Acceptable doses are generally those that are below a stated tolerance dose for development of some level of complication. To support the work sponsored by the National Cancer Institute, data for the tolerance of normal tissues or organs to low-LET radiation has been compiled from a number of sources. These tolerance dose data are ostensibly for uniform irradiation of all or part of an organ, and are for either 5% (TD 5 ) or 50% (TD 50 ) complication probability. The ''size'' of the irradiated organ is variously stated in terms of the absolute volume or the fraction of the organ volume irradiated, or the area or the length of the treatment field. The accuracy of these data is questionable. Much of the data represent doses that one or several experienced therapists have estimated could be safely given rather than quantitative analyses of clinical observations. Because these data have been obtained from multiple sources with possible different criteria for the definition of a complication, there are sometimes different values for what is apparently the same end point. 20 refs., 1 fig., 1 tab

  18. Assessment of maximum tolerated dose of a new herbal drug, Semelil (ANGIPARSTM in patients with diabetic foot ulcer: A Phase I clinical trial

    Directory of Open Access Journals (Sweden)

    Heshmat R

    2008-04-01

    Full Text Available Background and the purpose of the study: In many cases of diabetic foot ulcer (DFU management, wound healing is incomplete, and wound closure and epithelial junctional integrity are rarely achieved. Our aim was to evaluate the maximum tolerated dose (MTD and dose-limiting toxicity (DLT of Semelil (ANGIPARSTM, a new herbal compound for wound treatment in a Phase I clinical trial.Methods: In this open label study, six male diabetic patients with a mean age of 57±7.6 years were treated with escalating intravenous doses of Semelil, which started at 2 cc/day to 13.5 cc/day for 28 days. Patients were assessed with a full physical exam; variables which analyzed included age, past history of diabetes and its duration, blood pressure, body temperature, weight, characteristics of DFU, Na, K, liver function test, Complete Blood Count and Differential(CBC & diff, serum amylase, HbA1c, PT, PTT, proteinuria, hematuria, and side effects were recorded. All the measurements were taken at the beginning of treatment, the end of week 2 and week 4. We also evaluated Semelil's side effects at the end of weeks 4 and 8 after ending therapy.Results and major conclusions: Up to the drug dose of 10 cc/day foot ulcer dramatically improved. We did not observe any clinical or laboratory side effects at this or lower dose levels in diabetic patients. With daily dose of 13.5 cc of Semelil we observed phlebitis at the infusion site, which was the only side effect. Therefore, in this study we determined the MTD of Semelil at 10 cc/day, and the only DLT was phlebitis in injection vein. The recommended dose of Semelil I.V. administration for Phase II studies was 4 cc/day.

  19. Encoding Strategy for Maximum Noise Tolerance Bidirectional Associative Memory

    National Research Council Canada - National Science Library

    Shen, Dan

    2003-01-01

    In this paper, the Basic Bidirectional Associative Memory (BAM) is extended by choosing weights in the correlation matrix, for a given set of training pairs, which result in a maximum noise tolerance set for BAM...

  20. SU-D-204-02: BED Consistent Extrapolation of Mean Dose Tolerances

    Energy Technology Data Exchange (ETDEWEB)

    Perko, Z; Bortfeld, T; Hong, T; Wolfgang, J; Unkelbach, J [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: The safe use of radiotherapy requires the knowledge of tolerable organ doses. For experimental fractionation schemes (e.g. hypofractionation) these are typically extrapolated from traditional fractionation schedules using the Biologically Effective Dose (BED) model. This work demonstrates that using the mean dose in the standard BED equation may overestimate tolerances, potentially leading to unsafe treatments. Instead, extrapolation of mean dose tolerances should take the spatial dose distribution into account. Methods: A formula has been derived to extrapolate mean physical dose constraints such that they are mean BED equivalent. This formula constitutes a modified BED equation where the influence of the spatial dose distribution is summarized in a single parameter, the dose shape factor. To quantify effects we analyzed 14 liver cancer patients previously treated with proton therapy in 5 or 15 fractions, for whom also photon IMRT plans were available. Results: Our work has two main implications. First, in typical clinical plans the dose distribution can have significant effects. When mean dose tolerances are extrapolated from standard fractionation towards hypofractionation they can be overestimated by 10–15%. Second, the shape difference between photon and proton dose distributions can cause 30–40% differences in mean physical dose for plans having the same mean BED. The combined effect when extrapolating proton doses to mean BED equivalent photon doses in traditional 35 fraction regimens resulted in up to 7–8 Gy higher doses than when applying the standard BED formula. This can potentially lead to unsafe treatments (in 1 of the 14 analyzed plans the liver mean dose was above its 32 Gy tolerance). Conclusion: The shape effect should be accounted for to avoid unsafe overestimation of mean dose tolerances, particularly when estimating constraints for hypofractionated regimens. In addition, tolerances established for a given treatment modality cannot

  1. Normal tissue tolerance to external beam radiation therapy: Peripheral nerves; Dose de tolerance a l'irradiation des tissus sains: les nerfs peripheriques

    Energy Technology Data Exchange (ETDEWEB)

    Henriques de Figueiredo, B.; Dejean, C.; Sargos, P.; Kantor, G. [Departement de radiotherapie, institut Bergonie, centre regional de lutte contre le cancer, 33 - Bordeaux (France); Huchet, A.; Mamou, N. [Service d' oncologie medicale et de radiotherapie, CHU Saint-Andre, 33 - Bordeaux (France); Loiseau, H. [Service de neurochirurgie, CHU Pellegrin, 33 - Bordeaux (France)

    2010-07-15

    Plexopathies and peripheral neuropathies appear progressively and with several years delay after radiotherapy. These lesions are observed principally after three clinical situations: supraclavicular and axillar irradiations for breast cancer, pelvic irradiations for various pathologies and limb irradiations for soft tissue sarcomas. Peripheral nerves and plexus (brachial and lumbosacral) are described as serial structures and are supposed to receive less than a given maximum dose linked to the occurrence of late injury. Literature data, mostly ancient, define the maximum tolerable dose to a threshold of 60 Gy and highlight also a great influence of fractionation and high fraction doses. For peripheral nerves, most frequent late effects are pain with significant differences of occurrence between 50 and 60 Gy. At last, associated pathologies (diabetes, vascular pathology, neuropathy) and associated treatments have probably to be taken into account as additional factors, which may increase the risk of these late radiation complications. (authors)

  2. An open-label, dose-titration tolerability study of atomoxetine hydrochloride in Japanese adults with attention-deficit/hyperactivity disorder.

    Science.gov (United States)

    Takahashi, Michihiro; Takita, Yasushi; Goto, Taro; Ichikawa, Hironobu; Saito, Kazuhiko; Matsumoto, Hideo; Tanaka, Yasuo

    2011-02-01

    The main purpose of this first atomoxetine study in Japanese adults with attention-deficit/hyperactivity disorder (ADHD) was to investigate the tolerability of an 8-week treatment regimen. This was an open-label, dose escalation study conducted in 45 Japanese patients aged at least 18 years with DSM-IV-defined ADHD. Patients received atomoxetine orally for 8 weeks. Atomoxetine administration was started at 40 mg/day (7 days), and subsequently increased to a maximum dose of 120 mg/day. Tolerability was assessed by discontinuation rate due to adverse events. Adverse events, laboratory tests, vital signs and electrocardiograms were collected. In addition, ADHD symptoms were assessed by using the Japanese version of the Conners' Adult ADHD Rating Scale-Investigator Rated: Screening Version (CAARS-Inv:SV) scores. Thirty-nine patients completed the study period. Atomoxetine was well tolerated with a 6.7% (3/45) discontinuation rate due to nausea, malaise and anorexia. The most commonly reported adverse events were nausea, nasopharyngitis and headache; there were no unexpected safety concerns. No deaths or serious adverse events were reported. Mean CAARS-Inv:SV-J total ADHD symptom scores decreased in a time-dependent manner; the mean change from baseline to endpoint was -15.0 (Patomoxetine was well tolerated in these patients and suggested that atomoxetine at a maximum dose of 120 mg/day would be safe in Japanese ADHD patients. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.

  3. 45 Gy - tolerance dose spinal cord - dogma or the facts?

    International Nuclear Information System (INIS)

    Maciejewski, B.; Hliniak, A.; Danczak-Ginalska, Z.; Meder, M.; Skolyszewski, J.; Reinfuss, M.; Korzeniowski, S.; Peszynski, J.; Jassem, J.

    1993-01-01

    Dose of 45 Gy as a tolerance dose for spinal cord was questioned based on review of clinical data. Some data show that for conventional fractionation with the dose per fraction of less than 2.0 Gy spinal cord tolerance dose may arise up to 50-55 Gy. This was the base for round-table discussion and the importance of clinical and physical risk factors of postirradiation spinal cord injury was discussed and previous diseases of spinal cord, size of dose per fraction and length of irradiated spinal cord were pointed out as high risk factors. It was concluded that from clinical point of view there is no reason and on need to verify and to increase tolerance dose for spinal cord. (author)

  4. A Phase Ib dose-escalation study to evaluate safety and tolerability of the addition of the aminopeptidase inhibitor tosedostat (CHR-2797) to paclitaxel in patients with advanced solid tumours

    NARCIS (Netherlands)

    C.M.L. Herpen (Carla); F.A.L.M. Eskens (Ferry); M.J.A. de Jonge (Maja); I.M.E. Desar (Ingrid); L. Hooftman (Leon); E. Bone (Elisabeth); J.N.H. Timmerbonte (Johanna); J. Verweij (Jaap)

    2010-01-01

    textabstractBackground: This Phase Ib dose-escalating study investigated safety, maximum tolerated dose (MTD), dose-limiting toxicity (DLT), pharmacokinetics (PK) and clinical antitumour activity of tosedostat (CHR-2797), an orally bioavailable aminopeptidase inhibitor, in combination with

  5. A Phase Ib dose-escalation study to evaluate safety and tolerability of the addition of the aminopeptidase inhibitor tosedostat (CHR-2797) to paclitaxel in patients with advanced solid tumours.

    NARCIS (Netherlands)

    Herpen, C.M.L. van; Eskens, F.A.; Jonge, M. de; Desar, I.M.E.; Hooftman, L.; Bone, E.A.; Timmer-Bonte, J.N.H.; Verweij, J.

    2010-01-01

    BACKGROUND: This Phase Ib dose-escalating study investigated safety, maximum tolerated dose (MTD), dose-limiting toxicity (DLT), pharmacokinetics (PK) and clinical antitumour activity of tosedostat (CHR-2797), an orally bioavailable aminopeptidase inhibitor, in combination with paclitaxel. METHODS:

  6. Tolerance doses for treatment planning

    International Nuclear Information System (INIS)

    Lyman, J.T.

    1985-10-01

    Data for the tolerance of normal tissues or organs to (low-LET) radiation has been compiled from a number of sources which are referenced at the end of this document. This tolerance dose data are ostensibly for uniform irradiation of all or part of an organ, and are for either 5% (TD 5 ) or 50% (TD 50 ) complication probability. The ''size'' of the irradiated organ is variously stated in terms of the absolute volume or the fraction of the organ volume irradiated, or the area or the length of the treatment field. The accuracy of these data is questionable. Much of the data represents doses that one or several experienced therapists have estimated could be safely given rather than quantitative analyses of clinical observations. Because these data have been obtained from multiple sources with possible different criteria for the definition of a complication, there are sometimes different values for what is apparently the same endpoint. The data from some sources shows a tendancy to be quantized in 5 Gy increments. This reflects the size of possible round off errors. It is believed that all these data have been accumulated without the benefit of 3-D dose distributions and therefore the estimates of the size of the volume and/or the uniformity of the irradiation may be less accurate than is now possible. 19 refs., 4 figs

  7. Microbial Biofilms: Persisters, Tolerance and Dosing

    Science.gov (United States)

    Cogan, N. G.

    2005-03-01

    Almost all moist surfaces are colonized by microbial biofilms. Biofilms are implicated in cross-contamination of food products, biofouling, medical implants and various human infections such as dental cavities, ulcerative colitis and chronic respiratory infections. Much of current research is focused on the recalcitrance of biofilms to typical antibiotic and antimicrobial treatments. Although the polymer component of biofilms impedes the penetration of antimicrobials through reaction-diffusion limitation, this does not explain the observed tolerance, it merely delays the action of the agent. Heterogeneities in growth-rate also slow the eradication of the bacteria since most antimicrobials are far less effective for non-growing, or slowly growing bacteria. This also does not fully describe biofilm tolerance, since heterogeneities arr primairly a result of nutrient consumption. In this investigation, we describe the formation of `persister' cells which neither grow nor die in the presence of antibiotics. We propose that the cells are of a different phenotype than typical bacterial cells and the expression of the phenotype is regulated by the growth rate and the antibiotic concentration. We describe several experiments which describe the dynamics of persister cells and which motivate a dosing protocol that calls for periodic dosing of the population. We then introduce a mathematical model, which describes the effect of such a dosing regiment and indicates that the relative dose/withdrawal times are important in determining the effectiveness of such a treatment. A reduced model is introduced and the similar behavior is demonstrated analytically.

  8. The tolerance efficiency of Panicum maximum and Helianthus annuus in TNT-contaminated soil and nZVI-contaminated soil.

    Science.gov (United States)

    Jiamjitrpanich, Waraporn; Parkpian, Preeda; Polprasert, Chongrak; Laurent, François; Kosanlavit, Rachain

    2012-01-01

    This study was designed to compare the initial method for phytoremediation involving germination and transplantation. The study was also to determine the tolerance efficiency of Panicum maximum (Purple guinea grass) and Helianthus annuus (Sunflower) in TNT-contaminated soil and nZVI-contaminated soil. It was found that the transplantation of Panicum maximum and Helianthus annuus was more suitable than germination as the initiate method of nano-phytoremediation potting test. The study also showed that Panicum maximum was more tolerance than Helianthus annuus in TNT and nZVI-contaminated soil. Therefore, Panicum maximum in the transplantation method should be selected as a hyperaccumulated plant for nano-phytoremediation potting tests. Maximum tolerance dosage of Panicum maximum to TNT-concentration soil was 320 mg/kg and nZVI-contaminated soil was 1000 mg/kg in the transplantation method.

  9. Pharmacokinetics, Safety and Tolerability of Sacubitril/Valsartan (LCZ696) After Single-Dose Administration in Healthy Chinese Subjects.

    Science.gov (United States)

    Han, Yi; Ayalasomayajula, Surya; Pan, Wei; Yang, Fan; Yuan, Yaozong; Langenickel, Thomas; Hinder, Markus; Kalluri, Sampath; Pal, Parasar; Sunkara, Gangadhar

    2017-02-01

    Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor (ARNI) and has been recently approved in several countries for the treatment of patients with heart failure and reduced ejection fraction. This was the first study conducted to characterise the pharmacokinetics of LCZ696 analytes (pro-drug sacubitril, active neprilysin inhibitor LBQ657 and valsartan) after single-dose administration of LCZ696 in healthy Chinese subjects. In this open-label, randomised, parallel-group study, following screening and baseline evaluation, eligible healthy subjects received single oral doses of LCZ696 50, 100, 200 or 400 mg. The pharmacokinetics, safety and tolerability of LCZ696 were assessed up to 72 h after dosing. A total of 40 healthy male subjects were enrolled, and all completed the study. Following oral administration, LCZ696 delivered systemic exposure to sacubitril, LBQ657 and valsartan with a median time to reach maximum plasma concentration (T max ) ranging from 0.50 to 1.25, 2.00 to 3.00 and 1.50 to 2.50 h, respectively, over the investigated dose range. The mean terminal elimination half-life (T 1/2 ) ranged from 0.89 to 1.35, 8.57 to 9.24 and 5.33 to 7.91 h for sacubitril, LBQ657 and valsartan, respectively. The area under the plasma concentration-time curve from time zero to the time of the last quantifiable concentration (AUC 0-last ), and maximum plasma concentration (C max ) for LBQ657 increased dose proportionally over the entire dose range. Dose linear increase in the exposure was observed across the dose range for sacubitril and valsartan. LCZ696 was safe and well tolerated at all doses in this study. Adverse events of only mild intensity, which required no treatment, were reported in 6 (15 %) subjects. The pharmacokinetic profiles of LCZ696 analytes in Chinese subjects are similar to those reported previously in Caucasian subjects.

  10. Application of organ tolerance dose-constraints in clinical studies in radiation oncology

    International Nuclear Information System (INIS)

    Doerr, Wolfgang; Herrmann, Thomas; Baumann, Michael

    2014-01-01

    In modern radiation oncology, tolerance dose-constraints for organs at risk (OAR) must be considered for treatment planning, but particularly in order to design clinical studies. Tolerance dose tables, however, only address one aspect of the therapeutic ratio of any clinical study, i.e., the limitation of adverse events, but not the desired potential improvement in the tumor effect of a novel treatment strategy. A sensible application of ''tolerance doses'' in a clinical situation requires consideration of various critical aspects addressed here: definition of tolerance dose, specification of an endpoint/symptom, consideration of radiation quality and irradiation protocol, exposed volume and dose distribution, and patient-related factors of radiosensitivity. The currently most comprehensive estimates of OAR radiation tolerance are in the QUANTEC compilations (2010). However, these tolerance dose values must only be regarded as a rough orientation and cannot answer the relevant question for the patients, i.e., if the study can achieve a therapeutic advantage; this can obviously be answered only by the final scientific analysis of the study results. Despite all limitations, the design of clinical studies should currently refer to the QUANTEC values for appreciation of the risk of complications, if needed supplemented by one's own data or further information from the literature. The implementation of a consensus on the safety interests of the patients and on an application and approval process committed to progress in medicine, with transparent quality-assuring requirements with regard to the structural safeguarding of the study activities, plays a central role in clinical research in radiation oncology. (orig.) [de

  11. Measurement and estimation of maximum skin dose to the patient for different interventional procedures

    International Nuclear Information System (INIS)

    Cheng Yuxi; Liu Lantao; Wei Kedao; Yu Peng; Yan Shulin; Li Tianchang

    2005-01-01

    Objective: To determine the dose distribution and maximum skin dose to the patient for four interventional procedures: coronary angiography (CA), hepatic angiography (HA), radiofrequency ablation (RF) and cerebral angiography (CAG), and to estimate the definitive effect of radiation on skin. Methods: Skin dose was measured using LiF: Mg, Cu, P TLD chips. A total of 9 measuring points were chosen on the back of the patient with two TLDs placed at each point, for CA, HA and RF interventional procedures, whereas two TLDs were placed on one point each at the postero-anterior (PA) and lateral side (LAT) respectively, during the CAG procedure. Results: The results revealed that the maximum skin dose to the patient was 1683.91 mGy for the HA procedure with a mean value of 607.29 mGy. The maximum skin dose at the PA point was 959.3 mGy for the CAG with a mean value of 418.79 mGy; While the maximum and the mean doses at the LAT point were 704 mGy and 191.52 mGy, respectively. For the RF procedure the maximum dose was 853.82 mGy and the mean was 219.67 mGy. For the CA procedure the maximum dose was 456.1 mGy and the mean was 227.63 mGy. Conclusion: All the measured dose values in this study are estimated ones which could not provide the accurate maximum value because it is difficult to measure using a great deal of TLDs. On the other hand, the small area of skin exposed to high dose could be missed as the distribution of the dose is successive. (authors)

  12. A Phase I randomized clinical trial testing the safety, tolerability and preliminary pharmacokinetics of the mGluR5 negative allosteric modulator GET 73 following single and repeated doses in healthy volunteers.

    Science.gov (United States)

    Haass-Koffler, Carolina L; Goodyear, Kimberly; Long, Victoria M; Tran, Harrison H; Loche, Antonella; Cacciaglia, Roberto; Swift, Robert M; Leggio, Lorenzo

    2017-11-15

    Preclinical work suggests that the metabotropic glutamate receptor subtype 5 (mGlu5) may represent a novel target to treat neuropsychiatric disorders, including alcohol use disorder and obesity. The goal of this first-in-man study was to evaluate the safety, tolerability and pharmacokinetics (PK) of GET 73 (PubChem SID: 329974174), a novel mGluR5 negative allosteric modulator. This was a double-blind, placebo-controlled, ascending dose, Phase I study conducted in healthy male volunteers in two experiments. GET 73 was administered as single ascending doses (N=48; Experiment 1; 10, 30, 100, 300, 450, 600-mg) or multiple ascending doses (N=32; Experiment 2; 100, 300, 450, 450-mg twice a day). Primary endpoints were the incidence of adverse events (AEs) among drug conditions and drug tolerability. The secondary endpoints were the PK parameters of GET 73 and its metabolite MET 2. Single GET 73 doses of up to 600-mg and repeated ascending doses of up to 450-mg twice/day were safe and well-tolerated. There were no serious or severe AEs. All AEs were mild or moderate in severity. Total GET 73 exposure increased with each increased GET 73 dose. A dose-related increase in mean maximum plasma drug concentration was observed after repeated dosing. Maximum plasma drug concentrations occurred between 0.5 and 2.05h after administration in all groups for both single and repeated doses. This first-in-human study indicates that GET 73, as single or multiple ascending doses, is safe and well-tolerated when administered to healthy male volunteers. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Safety, tolerability, pharmacokinetics and pharmacodynamics of single doses of empagliflozin, a sodium glucose cotransporter 2 (SGLT2) inhibitor, in healthy Japanese subjects.

    Science.gov (United States)

    Sarashina, Akiko; Koiwai, Kazuki; Seman, Leo J; Yamamura, Norio; Taniguchi, Atsushi; Negishi, Takahiro; Sesoko, Shogo; Woerle, Hans J; Dugi, Klaus A

    2013-01-01

    This randomized, placebo-controlled within dose groups, double-blind, single rising dose study investigated the safety, tolerability, pharmacokinetics and pharmacodynamics of 1 mg to 100 mg doses of empagliflozin in 48 healthy Japanese male subjects. Empagliflozin was rapidly absorbed, reaching peak levels in 1.25 to 2.50 h; thereafter, plasma concentrations declined in a biphasic fashion, with mean terminal elimination half-life ranging from 7.76 to 11.7 h. Increase in empagliflozin exposure was proportional to dose. Oral clearance was dose independent and ranged from 140 to 172 mL/min. In the 24 h following 100 mg empagliflozin administration, the mean (%CV) amount of glucose excreted in urine was 74.3 (17.1) g. The amount and the maximum rate of glucose excreted via urine increased with dose of empagliflozin. Nine adverse events, all of mild intensity, were reported by 8 subjects (7 with empagliflozin and 1 with the placebo). No hypoglycemia was reported. In conclusion, 1 mg to 100 mg doses of empagliflozin had a good safety and tolerability profile in healthy Japanese male subjects. Exposure to empagliflozin was dose proportional. The amount and rate of urinary glucose excretion were higher with empagliflozin than with the placebo, and increased with empagliflozin dose.

  14. Maximum likelihood estimation for cytogenetic dose-response curves

    International Nuclear Information System (INIS)

    Frome, E.L.; DuFrain, R.J.

    1986-01-01

    In vitro dose-response curves are used to describe the relation between chromosome aberrations and radiation dose for human lymphocytes. The lymphocytes are exposed to low-LET radiation, and the resulting dicentric chromosome aberrations follow the Poisson distribution. The expected yield depends on both the magnitude and the temporal distribution of the dose. A general dose-response model that describes this relation has been presented by Kellerer and Rossi (1972, Current Topics on Radiation Research Quarterly 8, 85-158; 1978, Radiation Research 75, 471-488) using the theory of dual radiation action. Two special cases of practical interest are split-dose and continuous exposure experiments, and the resulting dose-time-response models are intrinsically nonlinear in the parameters. A general-purpose maximum likelihood estimation procedure is described, and estimation for the nonlinear models is illustrated with numerical examples from both experimental designs. Poisson regression analysis is used for estimation, hypothesis testing, and regression diagnostics. Results are discussed in the context of exposure assessment procedures for both acute and chronic human radiation exposure

  15. Implications of the quadratic cell survival curve and human skin radiation ''tolerance doses'' on fractionation and superfractionation dose selection

    International Nuclear Information System (INIS)

    Douglas, B.G.

    1982-01-01

    An analysis of early published multifraction orthovoltage human acute skin irradiation tolerance isoeffect doses is presented. It indicates that human acute skin radiation reactions may result from the repetition, with each dose fraction, of a cell survival curve of the form: S = e/sup -(αD + βD 2 )/). The analysis also shows no need for an independent proliferation related time factor for skin, for daily treatments of six weeks or less in duration. The value obtained for the constant β/α for orthovoltage irradiation from these data is 2.9 x 10 -3 rad -1 for the cell line determining acute skin tolerance. A radiation isoeffect relationship, based on the quadratic cell survival curve, is introduced for human skin. This relationship has some advantages over the nominal standard dose (NSD). First, its use is not restricted to tolerance level reactions. Second, a modification of the relationship, which is also introduced, may be employed in the selection of doses per treatment when irradiation dose fractions are administered at short intervals where repair of sublethal injury is incomplete

  16. SODIUM BICARBONATE FACILITATES LOW-DOSE ORAL TOLERANCE TO PEANUT IN MICE

    Science.gov (United States)

    Rationale: Oral tolerance specifically inhibits production of allergic IgE antibody and is therefore a potential method for suppressing food allergy. We have previously demonstrated that a single oral dose of one mg is sufficient to induce oral tolerance to egg white but not pean...

  17. Maximum likelihood estimation for cytogenetic dose-response curves

    International Nuclear Information System (INIS)

    Frome, E.L; DuFrain, R.J.

    1983-10-01

    In vitro dose-response curves are used to describe the relation between the yield of dicentric chromosome aberrations and radiation dose for human lymphocytes. The dicentric yields follow the Poisson distribution, and the expected yield depends on both the magnitude and the temporal distribution of the dose for low LET radiation. A general dose-response model that describes this relation has been obtained by Kellerer and Rossi using the theory of dual radiation action. The yield of elementary lesions is kappa[γd + g(t, tau)d 2 ], where t is the time and d is dose. The coefficient of the d 2 term is determined by the recovery function and the temporal mode of irradiation. Two special cases of practical interest are split-dose and continuous exposure experiments, and the resulting models are intrinsically nonlinear in the parameters. A general purpose maximum likelihood estimation procedure is described and illustrated with numerical examples from both experimental designs. Poisson regression analysis is used for estimation, hypothesis testing, and regression diagnostics. Results are discussed in the context of exposure assessment procedures for both acute and chronic human radiation exposure

  18. Maximum likelihood estimation for cytogenetic dose-response curves

    Energy Technology Data Exchange (ETDEWEB)

    Frome, E.L; DuFrain, R.J.

    1983-10-01

    In vitro dose-response curves are used to describe the relation between the yield of dicentric chromosome aberrations and radiation dose for human lymphocytes. The dicentric yields follow the Poisson distribution, and the expected yield depends on both the magnitude and the temporal distribution of the dose for low LET radiation. A general dose-response model that describes this relation has been obtained by Kellerer and Rossi using the theory of dual radiation action. The yield of elementary lesions is kappa(..gamma..d + g(t, tau)d/sup 2/), where t is the time and d is dose. The coefficient of the d/sup 2/ term is determined by the recovery function and the temporal mode of irradiation. Two special cases of practical interest are split-dose and continuous exposure experiments, and the resulting models are intrinsically nonlinear in the parameters. A general purpose maximum likelihood estimation procedure is described and illustrated with numerical examples from both experimental designs. Poisson regression analysis is used for estimation, hypothesis testing, and regression diagnostics. Results are discussed in the context of exposure assessment procedures for both acute and chronic human radiation exposure.

  19. Ocular pharmacokinetics and tolerability of bimatoprost ophthalmic solutions administered once or twice daily in rabbits, and clinical dosing implications

    Science.gov (United States)

    Shen, Jie; Goodkin, Margot L; Tong, Warren; Attar, Mayssa

    2017-01-01

    Purpose Fixed-combination medications can benefit patients requiring multiple agents to lower their intraocular pressure (IOP), but combining agents with complementary mechanisms of action is challenging if their dosing frequency differs. This study compares in vivo pharmacokinetic and ocular tolerability of bimatoprost 0.01% ophthalmic solutions dosed once or twice daily. Reports of twice-daily dosing in glaucoma patients are also reviewed. Methods New Zealand White rabbits were administered bimatoprost 0.01% monotherapy or fixed-combination bimatoprost 0.01%/brimonidine 0.1%, once or twice daily in both eyes for 4 days. Ocular tissues were harvested and analyzed by liquid chromatography-tandem mass spectrometry. The pharmacokinetic parameters calculated included maximum observed concentration, time to maximum concentration, and area under the concentration-time curve. Results Due to extensive metabolism, bimatoprost concentration was below the quantitation limit by 1 hour post-dose in all samples. Bimatoprost acid exposure, however, could be measured up to 6–8 hours post-dose and was similar in the aqueous humor and iris-ciliary body (pharmacological site of action) of animals treated once or twice daily with either bimatoprost 0.01% or fixed-combination bimatoprost 0.01%/brimonidine 0.1%. Increasing dosage frequency in rabbits did not raise the incidence of drug-related conjunctival hyperemia (most common adverse event associated with bimatoprost use in humans), suggesting comparable ocular tolerability of the once- and twice-daily regimens for each formulation. Conclusion Bimatoprost 0.01% administered once or twice daily as monotherapy and in fixed-combination with brimonidine 0.1% in rabbits show similar pharmacokinetic profiles of bimatoprost acid, especially in the iris-ciliary body. Key findings from previous clinical studies suggest that by varying the concentration of benzalkonium chloride (a preservative with corneal penetration-enhancing properties

  20. WE-AB-207B-01: Dose Tolerance for SBRT/SABR

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, J [Johns Hopkins University, Baltimore, MD (United States)

    2016-06-15

    Purpose: Stereotactic body radiation therapy (SBRT) / stereotactic ablative body radiotherapy (SABR) is gaining popularity, but quantitative dose tolerance has still been lacking. To improve this, the April 2016 issue of Seminars in Radiation Oncology will have normal tissue complication probability (NTCP) models for 10 critical structures: optic pathway, cochlea, oral mucosa, esophagus, chestwall, aorta, bronchi, duodenum, small bowel, and spinal cord. Methods: The project included more than 1500 treatments in 1–5 fractions using CyberKnife, Gamma Knife, or LINAC, with 60 authors from 15 institutions. NTCP models were constructed from the 97 grade 2–3 complications, predominantly scored using the common terminology criteria for adverse events (CTCAEv4). Dose volume histogram (DVH) data from each institutional dataset was loaded into the DVH Evaluator software (DiversiLabs, LLC, Huntingdon Valley, Pa) for modeling. The current state of the literature for the critical structures was depicted using DVH Risk Maps: comparative graphs of dose tolerance limits that can include estimated risk levels, reported complications, DVH data for study patients, as well as high- and low-risk dose tolerance limits. Results: For relatively acceptable toxicity like grade 1–3 rib fractures and chestwall pain, the high-risk limits have 50% risk and the low-risk limits have 5% risk. Emami et al (IJROBP 1991 May 15;21(1):109–22) used 50% and 5% risk levels for all structures, whereas this effort used clinically acceptable ranges for each: in structures like aorta or spinal cord where complications must be avoided, the high- and low-risk limits have about 3% and 1% risk, respectively, in this issue of Seminars. These statistically based guidelines can help ensure plan quality for each patient. Conclusion: NTCP for SBRT is now becoming available. Hypofractionated dose tolerance can be dramatically different than extrapolations of conventional fractionation so NTCP analysis of the

  1. WE-AB-207B-01: Dose Tolerance for SBRT/SABR

    International Nuclear Information System (INIS)

    Grimm, J

    2016-01-01

    Purpose: Stereotactic body radiation therapy (SBRT) / stereotactic ablative body radiotherapy (SABR) is gaining popularity, but quantitative dose tolerance has still been lacking. To improve this, the April 2016 issue of Seminars in Radiation Oncology will have normal tissue complication probability (NTCP) models for 10 critical structures: optic pathway, cochlea, oral mucosa, esophagus, chestwall, aorta, bronchi, duodenum, small bowel, and spinal cord. Methods: The project included more than 1500 treatments in 1–5 fractions using CyberKnife, Gamma Knife, or LINAC, with 60 authors from 15 institutions. NTCP models were constructed from the 97 grade 2–3 complications, predominantly scored using the common terminology criteria for adverse events (CTCAEv4). Dose volume histogram (DVH) data from each institutional dataset was loaded into the DVH Evaluator software (DiversiLabs, LLC, Huntingdon Valley, Pa) for modeling. The current state of the literature for the critical structures was depicted using DVH Risk Maps: comparative graphs of dose tolerance limits that can include estimated risk levels, reported complications, DVH data for study patients, as well as high- and low-risk dose tolerance limits. Results: For relatively acceptable toxicity like grade 1–3 rib fractures and chestwall pain, the high-risk limits have 50% risk and the low-risk limits have 5% risk. Emami et al (IJROBP 1991 May 15;21(1):109–22) used 50% and 5% risk levels for all structures, whereas this effort used clinically acceptable ranges for each: in structures like aorta or spinal cord where complications must be avoided, the high- and low-risk limits have about 3% and 1% risk, respectively, in this issue of Seminars. These statistically based guidelines can help ensure plan quality for each patient. Conclusion: NTCP for SBRT is now becoming available. Hypofractionated dose tolerance can be dramatically different than extrapolations of conventional fractionation so NTCP analysis of the

  2. Induction of oral tolerance with micro-doses of ovomucoid depends on the length of the feeding period

    DEFF Research Database (Denmark)

    Kjær, Tanja; Frøkiær, Hanne

    2002-01-01

    Oral administration of antigen induces antigen-specific immunologic tolerance, which is known to be dose-dependent. We studied the influence of continuous oral administration of nanogram and microgram doses of antigen on oral tolerance induction. Mice were continuously exposed to varying doses (1...

  3. Maximum skin dose assessment in interventional cardiology: large area detectors and calculation methods

    International Nuclear Information System (INIS)

    Quail, E.; Petersol, A.

    2002-01-01

    Advances in imaging technology have facilitated the development of increasingly complex radiological procedures for interventional radiology. Such interventional procedures can involve significant patient exposure, although often represent alternatives to more hazardous surgery or are the sole method for treatment. Interventional radiology is already an established part of mainstream medicine and is likely to expand further with the continuing development and adoption of new procedures. Between all medical exposures, interventional radiology is first of the list of the more expansive radiological practice in terms of effective dose per examination with a mean value of 20 mSv. Currently interventional radiology contribute 4% to the annual collective dose, in spite of contributing to total annual frequency only 0.3% but considering the perspectives of this method can be expected a large expansion of this value. In IR procedures the potential for deterministic effects on the skin is a risk to be taken into account together with stochastic long term risk. Indeed, the International Commission on Radiological Protection (ICRP) in its publication No 85, affirms that the patient dose of priority concern is the absorbed dose in the area of skin that receives the maximum dose during an interventional procedure. For the mentioned reasons, in IR it is important to give to practitioners information on the dose received by the skin of the patient during the procedure. In this paper maximum local skin dose (MSD) is called the absorbed dose in the area of skin receiving the maximum dose during an interventional procedure

  4. In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Kropf Siegfried

    2011-09-01

    Full Text Available Abstract Background To assess brachytherapy catheter positioning accuracy and to evaluate the effects of prolonged irradiation time on the tolerance dose of normal liver parenchyma following single-fraction irradiation with 192 Ir. Materials and methods Fifty patients with 76 malignant liver tumors treated by computed tomography (CT-guided high-dose-rate brachytherapy (HDR-BT were included in the study. The prescribed radiation dose was delivered by 1 - 11 catheters with exposure times in the range of 844 - 4432 seconds. Magnetic resonance imaging (MRI datasets for assessing irradiation effects on normal liver tissue, edema, and hepatocyte dysfunction, obtained 6 and 12 weeks after HDR-BT, were merged with 3D dosimetry data. The isodose of the treatment plan covering the same volume as the irradiation effect was taken as a surrogate for the liver tissue tolerance dose. Catheter positioning accuracy was assessed by calculating the shift between the 3D center coordinates of the irradiation effect volume and the tolerance dose volume for 38 irradiation effects in 30 patients induced by catheters implanted in nearly parallel arrangement. Effects of prolonged irradiation were assessed in areas where the irradiation effect volume and tolerance dose volume did not overlap (mismatch areas by using a catheter contribution index. This index was calculated for 48 irradiation effects induced by at least two catheters in 44 patients. Results Positioning accuracy of the brachytherapy catheters was 5-6 mm. The orthogonal and axial shifts between the center coordinates of the irradiation effect volume and the tolerance dose volume in relation to the direction vector of catheter implantation were highly correlated and in first approximation identically in the T1-w and T2-w MRI sequences (p = 0.003 and p p = 0.001 and p = 0.004, respectively. There was a significant shift of the irradiation effect towards the catheter entry site compared with the planned dose

  5. Open-label, dose-titration tolerability study of atomoxetine hydrochloride in Korean, Chinese, and Taiwanese adults with attention-deficit/hyperactivity disorder.

    Science.gov (United States)

    Takahashi, Michihiro; Goto, Taro; Takita, Yasushi; Chung, Sang-Keun; Wang, Yufeng; Gau, Susan Shur-Fen

    2014-03-01

    The primary objective of this study was to assess the overall safety and tolerability of atomoxetine in Korean, Chinese, and Taiwanese adults with attention-deficit/hyperactivity disorder (ADHD). A total of 44 patients aged ≥18 years who met the Conners' Adult ADHD Diagnostic Interview for DSM-IV diagnostic criteria for ADHD were enrolled from China, Korea, and Taiwan. In this open-label, dose-escalation study, patients received atomoxetine orally once daily over a period of eight weeks, starting at 40 mg/day (one week) up to a maximum dosage of 120 mg/day. Tolerability was evaluated by rate of discontinuation due to adverse events. Safety was assessed by recording all adverse events, laboratory tests, vital signs, and electrocardiograms. ADHD symptoms were evaluated by the Conners' Adult ADHD Rating Scale-Investigator Rated: Screening Version (CAARS-Inv:SV) for efficacy assessment. Thirty-four patients (77.3%) completed the study. Atomoxetine was well tolerated with a discontinuation rate of 2.3% (1/44) due to adverse events. The most commonly reported adverse events were nausea, dizziness, and somnolence. The mean change from baseline to endpoint in CAARS-Inv:SV total ADHD symptom score was -12.5 (P atomoxetine clinical trial in adult patients with ADHD in China, Korea, and Taiwan. Atomoxetine was well tolerated in doses of up to 120 mg/day with no unknown safety concerns. Copyright © 2012 Blackwell Publishing Asia Pty Ltd.

  6. Ocular pharmacokinetics and tolerability of bimatoprost ophthalmic solutions administered once or twice daily in rabbits, and clinical dosing implications

    Directory of Open Access Journals (Sweden)

    Shen J

    2017-09-01

    Full Text Available Jie Shen,1 Margot L Goodkin,2 Warren Tong,2 Mayssa Attar3 1Clinical Pharmacology, 2Clinical Development, 3Clinical Pharmacology, Metabolism and Immunology, Allergan plc, Irvine, CA, USA Purpose: Fixed-combination medications can benefit patients requiring multiple agents to lower their intraocular pressure (IOP, but combining agents with complementary mechanisms of action is challenging if their dosing frequency differs. This study compares in vivo pharmacokinetic and ocular tolerability of bimatoprost 0.01% ophthalmic solutions dosed once or twice daily. Reports of twice-daily dosing in glaucoma patients are also reviewed.Methods: New Zealand White rabbits were administered bimatoprost 0.01% monotherapy or fixed-combination bimatoprost 0.01%/brimonidine 0.1%, once or twice daily in both eyes for 4 days. Ocular tissues were harvested and analyzed by liquid chromatography-tandem mass spectrometry. The pharmacokinetic parameters calculated included maximum observed concentration, time to maximum concentration, and area under the concentration-time curve.Results: Due to extensive metabolism, bimatoprost concentration was below the quantitation limit by 1 hour post-dose in all samples. Bimatoprost acid exposure, however, could be measured up to 6–8 hours post-dose and was similar in the aqueous humor and iris-ciliary body (pharmacological site of action of animals treated once or twice daily with either bimatoprost 0.01% or fixed-combination bimatoprost 0.01%/brimonidine 0.1%. Increasing dosage frequency in rabbits did not raise the incidence of drug-related conjunctival hyperemia (most common adverse event associated with bimatoprost use in humans, suggesting comparable ocular tolerability of the once- and twice-daily regimens for each formulation.Conclusion: Bimatoprost 0.01% administered once or twice daily as monotherapy and in fixed-combination with brimonidine 0.1% in rabbits show similar pharmacokinetic profiles of bimatoprost acid

  7. Lack of evidence for increased tolerance of rat spinal cord with decreasing fraction doses below 2 Gy

    International Nuclear Information System (INIS)

    Ang, K.K.; van der Kogel, A.J.; van der Schueren, E.

    1985-01-01

    The radiation tolerance of the spinal cord, both in man and in rats, has been shown to depend strongly on the size of the dose per fraction. With fraction doses down to about 2 Gy, the spinal cord tolerance can be predicted by a modified Ellis formula. More recently alternative isoeffect formulas were based on the linear-quadratic (LQ) model of cell survival where the effect of dose fractionation is characterized by the ratio α/β which varies from tissue to tissue. For the spinal cord, as well as for other late responding tissues, the ratio α/β is small, in contrast to most acutely responding tissues. Both the Ellis-type formula, and to a lesser extent the LQ-model, predict a continuously increasing tolerance dose with decreasing fraction size. From previous experiments on the rat cervical spinal cord with doses per fraction down to about 2 Gy, the ratio α/β was determined to be 1.7 Gy, and the LQ-model would predict a rise in tolerance with a reduction in fraction size to far below 2 Gy. Based on these predictions clinical studies have been initiated assuming a significantly increased tolerance by reduction of fraction size to about 1 Gy. However, in the present experiments no evidence was found for such an increase in tolerance with fraction sizes below 2 Gy

  8. A Fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation

    International Nuclear Information System (INIS)

    Li, Haisen S.; Romeijn, H. Edwin; Dempsey, James F.

    2006-01-01

    We developed an analytical method for determining the maximum acceptable grid size for discrete dose calculation in proton therapy treatment plan optimization, so that the accuracy of the optimized dose distribution is guaranteed in the phase of dose sampling and the superfluous computational work is avoided. The accuracy of dose sampling was judged by the criterion that the continuous dose distribution could be reconstructed from the discrete dose within a 2% error limit. To keep the error caused by the discrete dose sampling under a 2% limit, the dose grid size cannot exceed a maximum acceptable value. The method was based on Fourier analysis and the Shannon-Nyquist sampling theorem as an extension of our previous analysis for photon beam intensity modulated radiation therapy [J. F. Dempsey, H. E. Romeijn, J. G. Li, D. A. Low, and J. R. Palta, Med. Phys. 32, 380-388 (2005)]. The proton beam model used for the analysis was a near mono-energetic (of width about 1% the incident energy) and monodirectional infinitesimal (nonintegrated) pencil beam in water medium. By monodirection, we mean that the proton particles are in the same direction before entering the water medium and the various scattering prior to entrance to water is not taken into account. In intensity modulated proton therapy, the elementary intensity modulation entity for proton therapy is either an infinitesimal or finite sized beamlet. Since a finite sized beamlet is the superposition of infinitesimal pencil beams, the result of the maximum acceptable grid size obtained with infinitesimal pencil beam also applies to finite sized beamlet. The analytic Bragg curve function proposed by Bortfeld [T. Bortfeld, Med. Phys. 24, 2024-2033 (1997)] was employed. The lateral profile was approximated by a depth dependent Gaussian distribution. The model included the spreads of the Bragg peak and the lateral profiles due to multiple Coulomb scattering. The dependence of the maximum acceptable dose grid size on the

  9. Dose-dependent response of Trichoderma harzianum in improving drought tolerance in rice genotypes.

    Science.gov (United States)

    Pandey, Veena; Ansari, Mohammad W; Tula, Suresh; Yadav, Sandep; Sahoo, Ranjan K; Shukla, Nandini; Bains, Gurdeep; Badal, Shail; Chandra, Subhash; Gaur, A K; Kumar, Atul; Shukla, Alok; Kumar, J; Tuteja, Narendra

    2016-05-01

    This study demonstrates a dose-dependent response of Trichoderma harzianum Th-56 in improving drought tolerance in rice by modulating proline, SOD, lipid peroxidation product and DHN / AQU transcript level, and the growth attributes. In the present study, the effect of colonization of different doses of T. harzianum Th-56 strain in rice genotypes were evaluated under drought stress. The rice genotypes treated with increasing dose of T. harzianum strain Th-56 showed better drought tolerance as compared with untreated control plant. There was significant change in malondialdehyde, proline, higher superoxide dismutase level, plant height, total dry matter, relative chlorophyll content, leaf rolling, leaf tip burn, and the number of scorched/senesced leaves in T. harzianum Th-56 treated rice genotypes under drought stress. This was corroborated with altered expression of aquaporin and dehydrin genes in T. harzianum Th-56 treated rice genotypes. The present findings suggest that a dose of 30 g/L was the most effective in improving drought tolerance in rice, and its potential exploitation will contribute to the advancement of rice genotypes to sustain crop productivity under drought stress. Interaction studies of T. harzianum with three aromatic rice genotypes suggested that PSD-17 was highly benefitted from T. harzianum colonization under drought stress.

  10. A fixed-dose combination tablet of gemigliptin and metformin sustained release has comparable pharmacodynamic, pharmacokinetic, and tolerability profiles to separate tablets in healthy subjects.

    Science.gov (United States)

    Park, Sang-In; Lee, Howard; Oh, Jaeseong; Lim, Kyoung Soo; Jang, In-Jin; Kim, Jeong-Ae; Jung, Jong Hyuk; Yu, Kyung-Sang

    2015-01-01

    In type 2 diabetes mellitus, fixed-dose combination (FDC) can provide the complementary benefits of correction of multiple pathophysiologic defects such as dysfunctions in glycemic or metabolic control while improving compliance compared with separate tablets taken together. The objective of the study reported here was to compare the pharmacodynamic (PD), pharmacokinetic (PK), and tolerability profiles of gemigliptin and extended-release metformin (metformin XR) between FDC and separate tablets. A randomized, open-label, single-dose, two-way, two-period, crossover study was conducted in 28 healthy male volunteers. Two FDC tablets of gemigliptin/metformin 25/500 mg or separate tablets of gemigliptin (50 mg ×1) and metformin XR (500 mg ×2) were orally administered in each period. Serial blood samples were collected up to 48 hours post-dose to determine dipeptidyl peptidase 4 (DPP-4) activity using spectrophotometric assay and concentrations of gemigliptin and metformin using tandem mass spectrometry. Geometric mean ratios (GMRs) of FDC to separate tablet formulations and their 90% confidence intervals (CIs) were calculated to compare the PD and PK parameters between the two formulations. Tolerability was assessed throughout the study. The plasma DPP-4 activity-time curves of the FDC and the separate tablets almost overlapped, leading to a GMR (90% CI) of the FDC to separate tablets for the plasma DPP-4 activity and its maximum inhibition of 1.00 (0.97-1.04) and 0.92 (0.82-1.05), respectively. Likewise, all of the GMRs (90% CIs) of FDC to separate tablets for the area under the plasma concentration-time curve and maximum plasma concentration of gemigliptin and metformin fell entirely within the conventional bioequivalence range of 0.80-1.25. Both the FDC and separate tablets were well tolerated. The PD, PK, and tolerability profiles of gemigliptin and metformin XR in FDC and separate tablets were found to be comparable. The FDC tablet of gemigliptin and metformin

  11. Tolerance limits of X-ray image intensity

    International Nuclear Information System (INIS)

    Stargardt, A.; Juran, R.; Brandt, G.A.

    1985-01-01

    Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author)

  12. Temporal Lobe Reactions After Carbon Ion Radiation Therapy: Comparison of Relative Biological Effectiveness–Weighted Tolerance Doses Predicted by Local Effect Models I and IV

    Energy Technology Data Exchange (ETDEWEB)

    Gillmann, Clarissa, E-mail: clarissa.gillmann@med.uni-heidelberg.de [Department of Radiation Oncology and Radiation Therapy, Heidelberg University Hospital, Heidelberg (Germany); Jäkel, Oliver [Department of Radiation Oncology and Radiation Therapy, Heidelberg University Hospital, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg (Germany); Schlampp, Ingmar [Department of Radiation Oncology and Radiation Therapy, Heidelberg University Hospital, Heidelberg (Germany); Karger, Christian P. [Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg (Germany)

    2014-04-01

    Purpose: To compare the relative biological effectiveness (RBE)–weighted tolerance doses for temporal lobe reactions after carbon ion radiation therapy using 2 different versions of the local effect model (LEM I vs LEM IV) for the same patient collective under identical conditions. Methods and Materials: In a previous study, 59 patients were investigated, of whom 10 experienced temporal lobe reactions (TLR) after carbon ion radiation therapy for low-grade skull-base chordoma and chondrosarcoma at Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany in 2002 and 2003. TLR were detected as visible contrast enhancements on T1-weighted MRI images within a median follow-up time of 2.5 years. Although the derived RBE-weighted temporal lobe doses were based on the clinically applied LEM I, we have now recalculated the RBE-weighted dose distributions using LEM IV and derived dose-response curves with Dmax,V-1 cm³ (the RBE-weighted maximum dose in the remaining temporal lobe volume, excluding the volume of 1 cm³ with the highest dose) as an independent dosimetric variable. The resulting RBE-weighted tolerance doses were compared with those of the previous study to assess the clinical impact of LEM IV relative to LEM I. Results: The dose-response curve of LEM IV is shifted toward higher values compared to that of LEM I. The RBE-weighted tolerance dose for a 5% complication probability (TD{sub 5}) increases from 68.8 ± 3.3 to 78.3 ± 4.3 Gy (RBE) for LEM IV as compared to LEM I. Conclusions: LEM IV predicts a clinically significant increase of the RBE-weighted tolerance doses for the temporal lobe as compared to the currently applied LEM I. The limited available photon data do not allow a final conclusion as to whether RBE predictions of LEM I or LEM IV better fit better clinical experience in photon therapy. The decision about a future clinical application of LEM IV therefore requires additional analysis of temporal lobe reactions in a

  13. Tolerability in the elderly population of high-dose alpha lipoic acid: a potential antioxidant therapy for the eye

    Directory of Open Access Journals (Sweden)

    Sarezky D

    2016-09-01

    Full Text Available Daniel Sarezky, Aaishah R Raquib, Joshua L Dunaief, Benjamin J Kim Scheie Eye Institute, Department of Ophthalmology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA Purpose: Alpha lipoic acid (ALA is an antioxidant and iron-chelating supplement that has potential benefits for geographic atrophy in dry age-related macular degeneration as well as other eye diseases. The purpose of this study was to determine the tolerability of ALA in the elderly population. Patients and methods: Fifteen subjects, age ≥65 years, took sequential ALA doses of 600, 800, and 1,200 mg. Each dose was taken once daily with a meal for 5 days. After each dose was taken by the subjects for 5 days, the subjects were contacted by phone, a review of systems was performed, and they were asked if they thought they could tolerate taking that dose of ALA for an extended period of time. Results: The 600 mg dose was well tolerated. At the 800 mg dose, one subject had an intolerable flushing sensation. At the 1,200 mg dose, two subjects had intolerable upper gastrointestinal side effects and one subject had an intolerable flushing sensation. Subjects taking gastrointestinal prophylaxis medications had no upper gastrointestinal side effects. Conclusion: High-dose ALA is not completely tolerated by the elderly. These preliminary data suggest that gastrointestinal prophylaxis may improve tolerability. (ClinicalTrials.gov, NCT02613572. Keywords: age-related macular degeneration, geographic atrophy, antioxidant, gastrointestinal, dietary supplements, lipoic acid

  14. Application of organ tolerance dose-constraints in clinical studies in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Doerr, Wolfgang [Medical University/AKH Vienna, Dept. of Radiation Oncology/Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Comprehensive Cancer Center, Vienna (Austria); Technical University Dresden, Department of Radiotherapy and Radiation Oncology, OncoRay-National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, Dresden (Germany); Task Group ' ' Tolerance Doses' ' of the German Society for Radiation Oncology (DEGRO), Berlin (Germany); Herrmann, Thomas [Task Group ' ' Tolerance Doses' ' of the German Society for Radiation Oncology (DEGRO), Berlin (Germany); Baumann, Michael [Technical University Dresden, Department of Radiotherapy and Radiation Oncology, OncoRay-National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, Dresden (Germany); Task Group ' ' Tolerance Doses' ' of the German Society for Radiation Oncology (DEGRO), Berlin (Germany)

    2014-07-15

    In modern radiation oncology, tolerance dose-constraints for organs at risk (OAR) must be considered for treatment planning, but particularly in order to design clinical studies. Tolerance dose tables, however, only address one aspect of the therapeutic ratio of any clinical study, i.e., the limitation of adverse events, but not the desired potential improvement in the tumor effect of a novel treatment strategy. A sensible application of ''tolerance doses'' in a clinical situation requires consideration of various critical aspects addressed here: definition of tolerance dose, specification of an endpoint/symptom, consideration of radiation quality and irradiation protocol, exposed volume and dose distribution, and patient-related factors of radiosensitivity. The currently most comprehensive estimates of OAR radiation tolerance are in the QUANTEC compilations (2010). However, these tolerance dose values must only be regarded as a rough orientation and cannot answer the relevant question for the patients, i.e., if the study can achieve a therapeutic advantage; this can obviously be answered only by the final scientific analysis of the study results. Despite all limitations, the design of clinical studies should currently refer to the QUANTEC values for appreciation of the risk of complications, if needed supplemented by one's own data or further information from the literature. The implementation of a consensus on the safety interests of the patients and on an application and approval process committed to progress in medicine, with transparent quality-assuring requirements with regard to the structural safeguarding of the study activities, plays a central role in clinical research in radiation oncology. (orig.) [German] In der modernen Radioonkologie muessen Toleranzdosisgrenzen fuer die Risikoorgane (''organs at risk'', OAR) zur Behandlungsplanung, besonders aber zur Gestaltung klinischer Studien, herangezogen werden

  15. Pharmacokinetic properties and tolerability of low-dose SoluMatrix diclofenac.

    Science.gov (United States)

    Desjardins, Paul J; Olugemo, Kemi; Solorio, Daniel; Young, Clarence L

    2015-02-01

    This study compared the pharmacokinetic properties and safety profile of low-dose (18- and 35-mg) diclofenac capsules manufactured using SoluMatrix Fine Particle Technology (Trademark of iCeutica Inc. (Philadelphia, Pennsylvania), and the technology is licensed to Iroko Pharmaceuticals, LLC (Philadelphia, Pennsylvania) for exclusive use in NSAIDs), which produces submicron-sized drug particles with enhanced dissolution properties, to those of diclofenac potassium immediate-release (IR) 50-mg tablets. This Phase 1, single-center, randomized, open-label, single-dose crossover study was conducted in 40 healthy volunteers. Subjects received, in randomized order, SoluMatrix diclofenac 18- or 35-mg capsules in the fasting condition, SoluMatrix diclofenac 35-mg capsules under fed conditions, and diclofenac potassium IR 50-mg tablets under fasting and fed conditions. Pharmacokinetic parameters (T(max), C(max), AUC(0-t), AUC(0-∞)) were calculated from the concentrations of diclofenac in the plasma. Absorption, food effect, and dose proportionality were determined using a mixed-model ANOVA for C(max), AUC(0-t), AUC(0-∞). Tolerability was assessed by recording adverse events, physical examination findings, vital sign measurements: clinical laboratory test results. Overall, 35 healthy volunteers aged 18 to 52 years completed the study. The mean age of the subjects was 33.4 years, and approximately half were men (47.5%). Median T(max) values were similar between the low-dose SoluMatrix diclofenac 35-mg capsules and the diclofenac potassium IR 50-mg tablets (both, ~1.0 hour). The mean maximum plasma concentration (C(max)) after the administration of low-dose SoluMatrix diclofenac 35-mg capsules was 26% lower than that with diclofenac potassium IR 50-mg tablets under fasting conditions (868.72 vs 1194.21 ng/mL). The administration of low-dose SoluMatrix diclofenac 35-mg capsules was associated with a 23% lower overall systemic exposure compared with that of diclofenac

  16. Efficacy and Tolerability of High-Dose Escitalopram in Posttraumatic Stress Disorder.

    Science.gov (United States)

    Qi, Wei; Gevonden, Martin; Shalev, Arieh

    2017-02-01

    Open-label trials suggest that escitalopram (up to 20 mg/d) is an effective treatment for some, but not all posttraumatic stress disorder (PTSD) patients. Higher doses of escitalopram effectively reduced major depression symptoms in patients who had not responded to regular doses. The current study examines the efficacy, tolerability, and adherence to high-dose escitalopram in PTSD. Forty-five PTSD patients received 12 weeks of gradually increasing doses of escitalopram reaching 40 mg daily at 4 weeks. Among those, 12 participants received regular doses of antidepressants at study onset including escitalopram (n = 7). The Clinician-Administered PTSD Scale (CAPS) evaluated PTSD symptoms severity before treatment, at 3 months (upon treatment termination), and at 6 months (maintenance effect). A 20% reduction in CAPS scores was deemed clinically significant. Adverse events and medication adherence were monitored at each clinical session. Linear mixed-models analysis showed a significant reduction of mean CAPS scores (11.5 ± 18.1 points) at 3 months and maintenance of gains by 6 months (F2,34.56 = 8.15, P = 0.001). Eleven participants (34.3%) showed clinically significant improvement at 3 months. Only 9 participants (20%) left the study. There were no serious adverse events and few mild ones with only 2 adverse events (diarrhea, 11.1%; drowsiness, 11.1%) reported by more than 10% of participants. High doses of escitalopram are tolerable and well adhered to in PTSD. Their beneficial effect at a group level is due to a particularly good response in a subset of patients.Variability in prior pharmacological treatment precludes a definite attribution of the results to high doses of escitalopram.

  17. Effect of dose rate on intestinal tolerance in mice. Implications in radiotherapy

    International Nuclear Information System (INIS)

    Wambersie, A.; Stienon-Smoes, M.R.; Octave-Prignot, M.

    1978-01-01

    Effect of dose rate on intestinal tolerance after 60 Co irradiation was studied in BALB/c mice. Intestinal tolerance was assessed from LD50, after selective abdominal irradiation and after total body irradiation. Three dose rates were compared, corresponding to irradiation times of about 15-20 minutes ('acute irradiation' taken as reference), 5-6 hours and 10-15 hours. Irradiations were performed simultaneously, with three telecobaltherapy units, the dose rates being adjusted with lead shields and by increasing the distances. Comparison of the experimental data already published indicates that, for some biological systems and effects, additional dose necessary to reach a given effect when passing from 'acute' to 'continuous low dose rate' irradiation is comparable to that expected when considering only repair of sublethal lesions. For other biological systems and effects, it is necessary to consider, besides repair of sublethal lesions, other mechanisms such as cell distribution and, for tumours, the oxygen effect. A differential effect then appears to be possible. However, as far as the clinical applications are concerned, a general agreement is not yet reached on the exact shape of the iso-effect curves as a function of irradiation time for the effects relevant to radiation therapy [fr

  18. Clinical applicability of biologically effective dose calculation for spinal cord in fractionated spine stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Lee, Seung Heon; Lee, Kyu Chan; Choi, Jinho; Ahn, So Hyun; Lee, Seok Ho; Sung, Ki Hoon; Kil, Se Hee

    2015-01-01

    The aim of the study was to investigate whether biologically effective dose (BED) based on linear-quadratic model can be used to estimate spinal cord tolerance dose in spine stereotactic body radiation therapy (SBRT) delivered in 4 or more fractions. Sixty-three metastatic spinal lesions in 47 patients were retrospectively evaluated. The most frequently prescribed dose was 36 Gy in 4 fractions. In planning, we tried to limit the maximum dose to the spinal cord or cauda equina less than 50% of prescription or 45 Gy 2/2 . BED was calculated using maximum point dose of spinal cord. Maximum spinal cord dose per fraction ranged from 2.6 to 6.0 Gy (median 4.3 Gy). Except 4 patients with 52.7, 56.4, 62.4, and 67.9 Gy 2/2 , equivalent total dose in 2-Gy fraction of the patients was not more than 50 Gy 2/2 (12.1–67.9, median 32.0). The ratio of maximum spinal cord dose to prescription dose increased up to 82.2% of prescription dose as epidural spinal cord compression grade increased. No patient developed grade 2 or higher radiation-induced spinal cord toxicity during follow-up period of 0.5 to 53.9 months. In fractionated spine SBRT, BED can be used to estimate spinal cord tolerance dose, provided that the dose per fraction to the spinal cord is moderate, e.g. < 6.0 Gy. It appears that a maximum dose of up to 45–50 Gy 2/2 to the spinal cord is tolerable in 4 or more fractionation regimen

  19. Tolerance doses of cutaneous and mucosal tissues in ring-necked parakeets (Psittacula krameri) for external beam megavoltage radiation.

    Science.gov (United States)

    Barron, Heather W; Roberts, Royce E; Latimer, Kenneth S; Hernandez-Divers, Stephen; Northrup, Nicole C

    2009-03-01

    Currently used dosages for external-beam megavoltage radiation therapy in birds have been extrapolated from mammalian patients and often appear to provide inadequate doses of radiation for effective tumor control. To determine the tolerance doses of cutaneous and mucosal tissues of normal birds in order to provide more effective radiation treatment for tumors that have been shown to be radiation responsive in other species, ingluvial mucosa and the skin over the ingluvies of 9 ring-necked parakeets (Psittacula krameri) were irradiated in 4-Gy fractions to a total dose of either 48, 60, or 72 Gy using an isocentric cobalt-60 teletherapy unit. Minimal radiation-induced epidermal changes were present in the high-dose group histologically. Neither dose-related acute nor chronic radiation effects could be detected in any group grossly in cutaneous or mucosal tissue over a 9-month period. Radiation doses of 72 Gy in 4-Gy fractions were well tolerated in the small number of ring-necked parakeets in this initial tolerance dose study.

  20. Effect of the Maximum Dose on White Matter Fiber Bundles Using Longitudinal Diffusion Tensor Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Tong; Chapman, Christopher H. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Tsien, Christina [Department of Radiation Oncology, Washington University at St Louis, St Louis, Missouri (United States); Kim, Michelle; Spratt, Daniel E.; Lawrence, Theodore S. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Cao, Yue, E-mail: yuecao@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan (United States)

    2016-11-01

    Purpose: Previous efforts to decrease neurocognitive effects of radiation focused on sparing isolated cortical structures. We hypothesize that understanding temporal, spatial, and dosimetric patterns of radiation damage to whole-brain white matter (WM) after partial-brain irradiation might also be important. Therefore, we carried out a study to develop the methodology to assess radiation therapy (RT)–induced damage to whole-brain WM bundles. Methods and Materials: An atlas-based, automated WM tractography analysis was implemented to quantify longitudinal changes in indices of diffusion tensor imaging (DTI) of 22 major WM fibers in 33 patients with predominantly low-grade or benign brain tumors treated by RT. Six DTI scans per patient were performed from before RT to 18 months after RT. The DTI indices and planned doses (maximum and mean doses) were mapped onto profiles of each of 22 WM bundles. A multivariate linear regression was performed to determine the main dose effect as well as the influence of other clinical factors on longitudinal percentage changes in axial diffusivity (AD) and radial diffusivity (RD) from before RT. Results: Among 22 fiber bundles, AD or RD changes in 12 bundles were affected significantly by doses (P<.05), as the effect was progressive over time. In 9 elongated tracts, decreased AD or RD was significantly related to maximum doses received, consistent with a serial structure. In individual bundles, AD changes were up to 11.5% at the maximum dose locations 18 months after RT. The dose effect on WM was greater in older female patients than younger male patients. Conclusions: Our study demonstrates for the first time that the maximum dose to the elongated WM bundles causes post-RT damage in WM. Validation and correlative studies are necessary to determine the ability and impact of sparing these bundles on preserving neurocognitive function after RT.

  1. Buprenorphine dose induction in non-opioid-tolerant pre-release prisoners.

    Science.gov (United States)

    Vocci, Frank J; Schwartz, Robert P; Wilson, Monique E; Gordon, Michael S; Kinlock, Timothy W; Fitzgerald, Terrence T; O'Grady, Kevin E; Jaffe, Jerome H

    2015-11-01

    In a previously reported randomized controlled trial, formerly opioid-dependent prisoners were more likely to enter community drug abuse treatment when they were inducted in prison onto buprenorphine/naloxone (hereafter called buprenorphine) than when they received counseling without buprenorphine in prison (47.5% vs. 33.7%, p=0.012) (Gordon et al., 2014). In this communication we report on the results of the induction schedule and the adverse event profile seen in pre-release prisoners inducted onto buprenorphine. This paper examines the dose induction procedure, a comparison of the proposed versus actual doses given per week, and side effects reported for 104 adult participants who were randomized to buprenorphine treatment in prison. Self-reported side effects were analyzed using generalized estimated equations to determine changes over time in side effects. Study participants were inducted onto buprenorphine at a rate faster than the induction schedule. Of the 104 (72 males, 32 females) buprenorphine recipients, 64 (37 males, 27 females) remained on medication at release from prison. Nine participants (8.6%) discontinued buprenorphine because of unpleasant opioid side effects. There were no serious adverse events reported during the in-prison phase of the study. Constipation was the most frequent symptom reported (69 percent). Our findings suggest that buprenorphine administered to non-opioid-tolerant adults should be started at a lower, individualized dose than customarily used for adults actively using opioids, and that non-opioid-tolerant pre-release prisoners can be successfully inducted onto therapeutic doses prior to release. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. MAK and BAT values list 2017. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2017-01-01

    The MAK and BAT values list 2017 includes the maximum permissible concentrations at the place of work and biological tolerance values for working materials. The following working materials are covered: carcinogenic working materials, sensitizing materials and aerosols. The report discusses the restriction of exposure peaks, skin resorption, MAK (maximum working place concentration) values during pregnancy, germ cell mutagens and specific working materials. Importance and application of BAT (biological working material tolerance) values, list of materials, carcinogens, biological guide values and reference values are also included.

  3. MAK and BAT values list 2016. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2016-01-01

    The MAK and BAT values list 2016 includes the maximum permissible concentrations at the place of work and biological tolerance values for working materials. The following working materials are covered: carcinogenic working materials, sensitizing materials and aerosols. The report discusses the restriction of exposure peaks, skin resorption, MAK (maximum working place concentration) values during pregnancy, germ cell mutagens and specific working materials. Importance and application of BAT (biological working material tolerance) values, list of materials, carcinogens, biological guide values and reference values are also included.

  4. Radiation tolerance of the cervical spinal cord: incidence and dose-volume relationship of symptomatic and asymptomatic late effects following high dose irradiation of paraspinal tumors

    International Nuclear Information System (INIS)

    Liu, Mitchell C.C.; Munzenrider, John E.; Finkelstein, Dianne; Liebsch, Norbert; Adams, Judy; Hug, Eugen B.

    1997-01-01

    changes was between 2 and 8.5 months after radiation therapy. Two risk factors appeared to have significant impact when all incidences were considered: proton portion of tumor dose > 55 CGE (p=.023), and spinal cord surface dose ≥ 60 CGE (p=.045). For patients receiving 55 CGE to >1.5cc of spinal cord, the risk of developing imaging changes was significantly higher (p=.0074). Age < 40 years was found to be correlated with higher incidence of Lhermitt's syndrome (p=.002). No variable was significant for predicting incidence of sensory or motor deficits. Conclusions: For chordomas and chondrosarcomas of the cervical spine, requiring high radiation doses, the guidelines of limiting maximum spinal cord surface dose to ≤ 64 CGE and maximum spinal cord center dose to ≤ 53 CGE appears safe. For the patients who had been treated within the above tolerance dose, none of them had developed motor deficits. Both a significant dose response relationship as well as volume effect for symptomatic or asymptomatic spinal cord changes were observed. The incidence of 1 patient, who developed motor damage after higher radiation doses to the spinal cord than generally allowed, emphasizes the importance of strict guidelines for critical, normal tissues in high dose, conformal radiation treatment

  5. Safety, tolerability, pharmacokinetics, and pharmacodynamics of novel glucokinase activator HMS5552: results from a first-in-human single ascending dose study

    Directory of Open Access Journals (Sweden)

    Xu HR

    2016-05-01

    Full Text Available Hongrong Xu,1,* Lei Sheng,1,* Weili Chen,1 Fei Yuan,1 Mengjie Yang,1 Hui Li,1 Xuening Li,1 John Choi,2 Guiyu Zhao,2 Tianxin Hu,2 Yongguo Li,2 Yi Zhang,2 Li Chen2 1Department of Clinical Pharmacology, Zhongshan Hospital, Fudan University, Shanghai, 2Department of Clinical Research & Development, Hua Medicine, Shanghai, People’s Republic of China *These authors have contributed equally to this work Background: HMS5552, a novel fourth-generation glucokinase (GK activator, has demonstrated promising effects on glycemic control in preclinical models of type 2 diabetes. This single ascending dose study was conducted to investigate the safety, tolerability, pharmacokinetics (PK, and pharmacodynamics (PD of HMS5552 during its first-in-human exposure.Methods: Sixty healthy subjects were enrolled. In each of six dose-cohorts (5, 10, 15, 25, 35, and 50 mg, ten subjects were randomized with eight subjects receiving the same cohort-dose of HMS5552 and two receiving placebo. Plasma HMS5552 exposure, glucose, and insulin were measured repeatedly during fasting and after a standardized meal. Assessment included safety, PK, and PD endpoints.Results: HMS5552 showed dose-proportional increases in area under the curve 0 to the last quantifiable concentration (AUC0–t and maximum plasma concentration (Cmax. Slopes estimated by linear regression for AUC0–t and Cmax were ~1.0 (0.932 and 0.933, respectively. Geometric mean elimination half-life ranged from 4.48 to 7.51 hours and apparent clearance ranged from 11.5 to 13.1 L/h across all doses. No significant sex effect was observed in PK parameters. HMS5552 also demonstrated dose-related PD responses in terms of maximum glucose change from baseline (% and mean glucose area under effect curve 0–4 hours change from baseline (% (P<0.001. Fifteen adverse events were reported by nine subjects (ten with HMS5552 and five with the placebo. All adverse events were mild in intensity and resolved without any treatment

  6. Savannah River Site radioiodine atmospheric releases and offsite maximum doses

    International Nuclear Information System (INIS)

    Marter, W.L.

    1990-01-01

    Radioisotopes of iodine have been released to the atmosphere from the Savannah River Site since 1955. The releases, mostly from the 200-F and 200-H Chemical Separations areas, consist of the isotopes, I-129 and 1-131. Small amounts of 1-131 and 1-133 have also been released from reactor facilities and the Savannah River Laboratory. This reference memorandum was issued to summarize our current knowledge of releases of radioiodines and resultant maximum offsite doses. This memorandum supplements the reference memorandum by providing more detailed supporting technical information. Doses reported in this memorandum from consumption of the milk containing the highest I-131 concentration following the 1961 1-131 release incident are about 1% higher than reported in the reference memorandum. This is the result of using unrounded 1-131 concentrations of I-131 in milk in this memo. It is emphasized here that this technical report does not constitute a dose reconstruction in the same sense as the dose reconstruction effort currently underway at Hanford. This report uses existing published data for radioiodine releases and existing transport and dosimetry models

  7. Phase I dose-escalation study to examine the safety and tolerability of LY2603618, a checkpoint 1 kinase inhibitor, administered 1 day after pemetrexed 500 mg/m(2) every 21 days in patients with cancer.

    Science.gov (United States)

    Weiss, Glen J; Donehower, Ross C; Iyengar, Tara; Ramanathan, Ramesh K; Lewandowski, Karen; Westin, Eric; Hurt, Karla; Hynes, Scott M; Anthony, Stephen P; McKane, Scott

    2013-02-01

    This phase I study aims at assessing the safety and tolerability of LY2603618, a selective inhibitor of Checkpoint Kinase 1, in combination with pemetrexed and determining the maximum tolerable dose and the pharmacokinetic parameters. This was an open-label, multicenter, dose-escalation study in patients with advanced solid tumors. Increasing doses of LY2603618 (40-195 mg/m(2)) were combined with 500 mg/m(2) of pemetrexed. LY2603618 was administered on Days 1 and 9 and pemetrexed on Day 8 in a 28-day cycle. For all subsequent 21-day cycles, pemetrexed was administered on Day 1 and LY2603618 on Day 2. Antitumor activity was evaluated as per Response Evaluation Criteria in Solid Tumors 1.0. A total of 31 patients were enrolled into six cohorts (three at 40 mg/m(2) over 4.5-hour infusion, 1-hour infusion in subsequent cohorts: three each at 40 mg/m(2), 70 mg/m(2), and 195 mg/m(2); 13 at 105 mg/m(2); six at 150 mg/m(2)). Four patients experienced a dose-limiting toxicity: diarrhea (105 mg/m(2)); reversible infusion-related reaction (150 mg/m(2)); thrombocytopenia (195 mg/m(2)); and fatigue (195 mg/m(2)). The maximum tolerated dose was defined as 150 mg/m(2). The pharmacokinetic data demonstrated that the exposure of LY2603618 increased in a dose-dependent manner, displayed a suitable half-life for maintaining required human exposures while minimizing the intra- and inter-cycle accumulation, and was unaffected by the pemetrexed administration. The pharmacokinetic-defined biologically efficacious dose was achieved at doses ≥105 mg/m(2). LY2603618 administered approximately 24 h after pemetrexed showed acceptable safety and pharmacokinetic profiles.

  8. Prediction of the maximum dosage to man from the fallout of nuclear devices V. Estimation of the maximum dose from internal emitters in aquatic food supply

    International Nuclear Information System (INIS)

    Tamplin, A.R.; Fisher, H.L.; Chapman, W.H.

    1968-01-01

    A method is described for estimating the maximum internal dose that could result from the radionuclides released to an aquatic environment. By means of this analysis one can identify the nuclides that could contribute most to the internal dose, and determine the contribution of each nuclide to the total dose. The calculations required to estimate the maximum dose to an infant's bone subsequent to the construction of a sea-level canal are presented to illustrate the overall method. The results are shown to serve the basic aims of preshot rad-safe analysis and of guidance for postshot documentation. The usefulness of the analysis in providing guidance for device design is further pointed out. (author)

  9. Sodium phenylbutyrate in Huntington's disease: a dose-finding study.

    Science.gov (United States)

    Hogarth, Penelope; Lovrecic, Luca; Krainc, Dimitri

    2007-10-15

    Transcriptional dysregulation in Huntington's disease (HD) is mediated in part by aberrant patterns of histone acetylation. We performed a dose-finding study in human HD of sodium phenylbutyrate (SPB), a histone deacetylase inhibitor that ameliorates the HD phenotype in animal models. We used a dose-escalation/de-escalation design, using prespecified toxicity criteria and standard clinical and laboratory safety measures. The maximum tolerated dose was 15 g/day. At higher doses, toxicity included vomiting, lightheadedness, confusion, and gait instability. We saw no significant laboratory or electrocardiographic abnormalities. Gene expression changes in blood suggested an inverse dose-response. In conclusion, SPB at 12 to 15 g/day appears to be safe and well-tolerated in human HD. 2007 Movement Disorder Society

  10. Calculate the maximum expected dose for technical radio physicists a cobalt machine

    International Nuclear Information System (INIS)

    Avila Avila, Rafael; Perez Velasquez, Reytel; Gonzalez Lapez, Nadia

    2009-01-01

    Considering the daily operations carried out by technicians Radiophysics Medical Service Department of Radiation Oncology Hospital V. General Teaching I. Lenin in the city of Holguin, during a working week (Between Monday and Friday) as an important element in calculating the maximum expected dose (MDE). From the exponential decay law which is subject the source activity, we propose corrections to the cumulative doses in the weekly period, leading to obtaining a formula which takes into a cumulative dose during working days and sees no dose accumulation of rest days (Saturday and Sunday). The estimate factor correction is made from a power series expansion convergent is truncated at the n-th term coincides with the week period for which you want to calculate the dose. As initial condition is adopted ambient dose equivalent rate as a given, which allows estimate MDE in the moments after or before this. Calculations were proposed use of an Excel spreadsheet that allows simple and accessible processing the formula obtained. (author)

  11. Application of maximum values for radiation exposure and principles for the calculation of radiation doses

    International Nuclear Information System (INIS)

    2007-08-01

    The guide presents the definitions of equivalent dose and effective dose, the principles for calculating these doses, and instructions for applying their maximum values. The limits (Annual Limit on Intake and Derived Air Concentration) derived from dose limits are also presented for the purpose of monitoring exposure to internal radiation. The calculation of radiation doses caused to a patient from medical research and treatment involving exposure to ionizing radiation is beyond the scope of this ST Guide

  12. MAK and BAT values list 2015. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2015-01-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2015 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  13. MAK and BAT values list 2014. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2014-01-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2014 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  14. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    Science.gov (United States)

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  15. A Phase I Study of the Safety and Pharmacokinetics of Higher-Dose Icotinib in Patients With Advanced Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Liu, Jian; Wu, Lihua; Wu, Guolan; Hu, Xingjiang; Zhou, Huili; Chen, Junchun; Zhu, Meixiang; Xu, Wei; Tan, Fenlai; Ding, Lieming; Wang, Yinxiang; Shentu, Jianzhong

    2016-11-01

    This phase I study evaluated the maximum tolerated dose, dose-limiting toxicities, safety, pharmacokinetics, and efficacy of icotinib with a starting dose of 250 mg in pretreated, advanced non-small cell lung cancer patients. We observed a maximum tolerated dose of 500 mg with a favorable pharmacokinetics profile and antitumor activity.These findings provide clinicians with evidence for application of higher-dose icotinib. Icotinib, an oral epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor, has shown favorable tolerability and antitumor activity at 100-200 mg in previous studies without reaching the maximum tolerated dose (MTD). In July 2011, icotinib was approved by the China Food and Drug Administration at a dose of 125 mg three times daily for the treatment of patients with locally advanced or metastatic non-small cell lung cancer (NSCLC) after failure of at least one platinum-based chemotherapy regimen. This study investigated the MTD, tolerability, and pharmacokinetics of higher-dose icotinib in patients with advanced NSCLC. Twenty-six patients with advanced NSCLC were treated at doses of 250-625 mg three times daily The EGFR mutation test was not mandatory in this study. Twenty-four (92.3%) of 26 patients experienced at least one adverse event (AE); rash (61.5%), diarrhea (23.1%), and oral ulceration (11.5%) were most frequent AEs. Dose-limiting toxicities were seen in 2 of 6 patients in the 625-mg group, and the MTD was established at 500 mg. Icotinib was rapidly absorbed and eliminated. The amount of time that the drug was present at the maximum concentration in serum (T max ) ranged from 1 to 3 hours (1.5-4 hours) after multiple doses. The t 1/2 was similar after single- and multiple-dose administration (7.11 and 6.39 hours, respectively). A nonlinear relationship was observed between dose and drug exposure. Responses were seen in 6 (23.1%) patients, and 8 (30.8%) patients had stable disease. This study demonstrated that higher-dose

  16. Estimation of maximum credible atmospheric radioactivity concentrations and dose rates from nuclear tests

    International Nuclear Information System (INIS)

    Telegadas, K.

    1979-01-01

    A simple technique is presented for estimating maximum credible gross beta air concentrations from nuclear detonations in the atmosphere, based on aircraft sampling of radioactivity following each Chinese nuclear test from 1964 to 1976. The calculated concentration is a function of the total yield and fission yield, initial vertical radioactivity distribution, time after detonation, and rate of horizontal spread of the debris with time. calculated maximum credible concentrations are compared with the highest concentrations measured during aircraft sampling. The technique provides a reasonable estimate of maximum air concentrations from 1 to 10 days after a detonation. An estimate of the whole-body external gamma dose rate corresponding to the maximum credible gross beta concentration is also given. (author)

  17. Quantitative in vivo assessment of radiation injury of the liver using Gd-EOB-DTPA enhanced MRI: tolerance dose of small liver volumes

    Directory of Open Access Journals (Sweden)

    Pech Maciej

    2011-04-01

    Full Text Available Abstract Backround Hepatic radiation toxicity restricts irradiation of liver malignancies. Better knowledge of hepatic tolerance dose is favourable to gain higher safety and to optimize radiation regimes in radiotherapy of the liver. In this study we sought to determine the hepatic tolerance dose to small volume single fraction high dose rate irradiation. Materials and methods 23 liver metastases were treated by CT-guided interstitial brachytherapy. MRI was performed 3 days, 6, 12 and 24 weeks after therapy. MR-sequences were conducted with T1-w GRE enhanced by hepatocyte-targeted Gd-EOB-DTPA. All MRI data sets were merged with 3D-dosimetry data. The reviewer indicated the border of hypointensity on T1-w images (loss of hepatocyte function or hyperintensity on T2-w images (edema. Based on the volume data, a dose-volume-histogram was calculated. We estimated the threshold dose for edema or function loss as the D90, i.e. the dose achieved in at least 90% of the pseudolesion volume. Results At six weeks post brachytherapy, the hepatocyte function loss reached its maximum extending to the former 9.4Gy isosurface in median (i.e., ≥9.4Gy dose exposure led to hepatocyte dysfunction. After 12 and 24 weeks, the dysfunctional volume had decreased significantly to a median of 11.4Gy and 14Gy isosurface, respectively, as a result of repair mechanisms. Development of edema was maximal at six weeks post brachytherapy (9.2Gy isosurface in median, and regeneration led to a decrease of the isosurface to a median of 11.3Gy between 6 and 12 weeks. The dose exposure leading to hepatocyte dysfunction was not significantly different from the dose provoking edema. Conclusion Hepatic injury peaked 6 weeks after small volume irradiation. Ongoing repair was observed up to 6 months. Individual dose sensitivity may differ as demonstrated by a relatively high standard deviation of threshold values in our own as well as all other published data.

  18. Evaluation of dose components for healthy tissue tolerance studies on dogs at the HFR Petten

    International Nuclear Information System (INIS)

    Watkins, P.; Moss, R.L.; Siefert, A.; Huiskamp, R.; Gavin, P.; Konijnenberg, M.

    1993-01-01

    Before the start of clinical trails of BNCT on glioma patients at the Petten reactor, certain preconditions must be determined. In particular the tolerance of healthy brain tissue exposed to the epithermal neutron beam requires investigation. In these studies, beagle dogs have been subjected to different levels of irradiation and 10 B, the latter in the form of BSH. To support this work a treatment planning tool is being developed to predict the various dose components within the treatment volume. A Monte Carlo code, MCNP, has been used to simulate the particle transport and to predict the different dose rate distributions. The doses rates generated by MCNP are manipulated with a processing code, TREAT, to give irradiation times, peak dose positions and to display the required data in a graphical format. This paper explains the basic methodology used in the system and a practical case is presented for one of the healthy tissue tolerance dogs. Doses, both physical and RBE weighted, have been produced for pre-treatment planning studies

  19. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Y; Yu, J; Xiao, Y [Thomas Jefferson University Hospital, Philadelphia, PA (United States)

    2015-06-15

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematical model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant.

  20. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    International Nuclear Information System (INIS)

    Gong, Y; Yu, J; Xiao, Y

    2015-01-01

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematical model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant

  1. Melatonin for Sleep in Children with Autism: A Controlled Trial Examining Dose, Tolerability, and Outcomes

    Science.gov (United States)

    Malow, Beth; Adkins, Karen W.; McGrew, Susan G.; Wang, Lily; Goldman, Suzanne E.; Fawkes, Diane; Burnette, Courtney

    2012-01-01

    Supplemental melatonin has shown promise in treating sleep onset insomnia in children with autism spectrum disorders (ASD). Twenty-four children, free of psychotropic medications, completed an open-label dose-escalation study to assess dose-response, tolerability, safety, feasibility of collecting actigraphy data, and ability of outcome measures…

  2. Paralysis following stereotactic spinal irradiation in pigs suggests a tolerance constraint for single-session irradiation of the spinal nerve

    International Nuclear Information System (INIS)

    Medin, Paul M.; Foster, Ryan D.; Kogel, Albert J. van der; Meyer, Jeffrey; Sayre, James W.; Huang, Hao; Öz, Orhan K.

    2013-01-01

    Background and purpose: Paralysis observed during a study of vertebral bone tolerance to single-session irradiation led to further study of the dose-related incidence of motor peripheral neuropathy. Materials and methods: During a bone tolerance study, cervical spinal nerves of 15 minipigs received bilateral irradiation to levels C5–C8 distributed into three dose groups with mean maximum spinal nerve doses of 16.9 ± 0.3 Gy (n = 5), 18.7 ± 0.5 Gy (n = 5), and 24.3 ± 0.8 Gy (n = 5). Changes developing in the gait of the group of pigs receiving a mean maximum dose of 24.3 Gy after 10–15 weeks led to the irradiation of two additional animals. They received mean maximum dose of 24.9 ± 0.2 Gy (n = 2), targeted to the left spinal nerves of C5–C8. The followup period was one year. Histologic sections from spinal cords and available spinal nerves were evaluated. MR imaging was performed on pigs in the 24.9 Gy group. Results: No pig that received a maximum spinal nerve point dose ⩽19.0 Gy experienced a change in gait while all pigs that received ⩾24.1 Gy experienced paralysis. Extensive degeneration and fibrosis were observed in irradiated spinal nerves of the 24.9 Gy animals. All spinal cord sections were normal. Irradiated spinal nerve regions showed increased thickness and hypointensity on MR imaging. Conclusion: The single-session tolerance dose of the cervical spinal nerves lies between 19.0 and 24.1 Gy for this model

  3. Normal tissue tolerance to external beam radiation therapy: The stomach; Dose de tolerance a l'irradiation des tissus sains: l'estomac

    Energy Technology Data Exchange (ETDEWEB)

    Oberdiac, P. [Service de radiotherapie, hopital de Bellevue, CHU de Saint-Etienne, 42 - Saint-Etienne (France); Mineur, L. [Unite d' oncologie digestive et radiotherapie, institut Sainte-Catherine, 84 - Avignon (France)

    2010-07-15

    In the following article, we will discuss general issues relating to acute and late gastric's radiation toxicities. The tolerance of the stomach to complete or partial organ irradiation is more un-appreciated than for most other organs. We consulted the Medline database via PubMed and used the key words gastric - radiotherapy - toxicity. Currently, 60 Gy or less is prescribed in gastric radiation therapy. Acute clinical toxicity symptoms are predominantly nausea and vomiting. Although there is a general agreement that the whole stomach tolerance is for doses of 40 to 45 Gy without unacceptable complication, it is well established that a stomach dose of 35 Gy increases the risk of ulcer complications. (authors)

  4. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  5. Application of maximum values for radiation exposure and principles for the calculation of radiation dose

    International Nuclear Information System (INIS)

    2000-01-01

    The guide sets out the mathematical definitions and principles involved in the calculation of the equivalent dose and the effective dose, and the instructions concerning the application of the maximum values of these quantities. further, for monitoring the dose caused by internal radiation, the guide defines the limits derived from annual dose limits (the Annual Limit on Intake and the Derived Air Concentration). Finally, the guide defines the operational quantities to be used in estimating the equivalent dose and the effective dose, and also sets out the definitions of some other quantities and concepts to be used in monitoring radiation exposure. The guide does not include the calculation of patient doses carried out for the purposes of quality assurance

  6. Application of maximum values for radiation exposure and principles for the calculation of radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The guide sets out the mathematical definitions and principles involved in the calculation of the equivalent dose and the effective dose, and the instructions concerning the application of the maximum values of these quantities. further, for monitoring the dose caused by internal radiation, the guide defines the limits derived from annual dose limits (the Annual Limit on Intake and the Derived Air Concentration). Finally, the guide defines the operational quantities to be used in estimating the equivalent dose and the effective dose, and also sets out the definitions of some other quantities and concepts to be used in monitoring radiation exposure. The guide does not include the calculation of patient doses carried out for the purposes of quality assurance.

  7. Studies on the establishment of maximum permissible exposure dose for reference Korean

    International Nuclear Information System (INIS)

    Kim, Y.J.; Lee, K.S.; Chun, K.C.; Kim, C.B.; Chung, K.H.; Kim, S.L.; Kim, M.J.

    1981-01-01

    In order to establish the Reference Korean and maximum permissible exposure dose of Reference Korean, for the first year a total of 9,758 males and 7,019 females were surveyed for the height, weight, a body surface area, and a total of 879 individuals of 180 households located in different 30 localities were analyzed for food consumption and a total of radioactive substances (β-ray) contained in food per capita per day. In this report the external and internal exposure dose were also estimated on the basis of data mostly published in other country as well as in Korea in part

  8. Hazards and maximum permissible doses of radiation for man

    International Nuclear Information System (INIS)

    Walinder, G.

    1977-11-01

    Maximum permissible dose levels are primarely based on risks for genetic damage and cancer. The reason for this is the observation that such late effects of radiation seem to arise even after doses that are to low to give rise to acute effects. In contrast to the tumour incidence found in irradiated human populations no genetic effects of radiation have been observed in man. This does not mean that genetic effects have not been induced but that it has been impossible to find an increase or to discern them among all the congenital defects, that can not be ascribed to the irradiation. As a consequence, the radiological risk estimation has been concentrated on the hazard of malignant diseases. Tumour risks are generally expressed as excess rates of incidence and mortality per million persons per rem. These figures are, however, not obtained from direct epidemiological observations but have been calculated from such data under the assumption of a linear relationship between effect and radiation dose. This formal extrapolation of observed data involves an uncertainty which, of course, is proportionately greater for the calculated effects in the millirem range. However, although the calculated tumour risks can not be said to be founded on direct scientific evidence, there are scientific reasons to believe that the figures derived from the formal extrapolations constitute an upper limit of possible ri02050

  9. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  10. A Phase I Dose-Escalation Study of Antibody BI-505 in Relapsed/Refractory Multiple Myeloma

    DEFF Research Database (Denmark)

    Hansson, Markus; Gimsing, Peter; Badros, Ashraf

    2015-01-01

    PURPOSE: This multicenter, first-in-human study evaluated safety, tolerability, pharmacokinetics, and pharmacodynamics of BI-505, a human anti-ICAM-1 monoclonal antibody, in advanced relapsed/refractory multiple myeloma patients. EXPERIMENTAL DESIGN: BI-505 was given intravenously, every 2 weeks...... generally mild to moderate, and those attributed to study medication were mostly limited to the first dose and manageable with premedication and slower infusion. No maximum tolerated dose was identified. BI-505's half-life increased with dose while clearance decreased, suggesting target-mediated clearance...

  11. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  12. Evaluating the maximum patient radiation dose in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, M.; Chida, K.; Sato, T.; Oosaka, H.; Tosa, T.; Kadowaki, K.

    2011-01-01

    Many of the X-ray systems that are used for cardiac interventional radiology provide no way to evaluate the patient maximum skin dose (MSD). The authors report a new method for evaluating the MSD by using the cumulative patient entrance skin dose (ESD), which includes a back-scatter factor and the number of cine-angiography frames during percutaneous coronary intervention (PCI). Four hundred consecutive PCI patients (315 men and 85 women) were studied. The correlation between the cumulative ESD and number of cine-angiography frames was investigated. The irradiation and overlapping fields were verified using dose-mapping software. A good correlation was found between the cumulative ESD and the number of cine-angiography frames. The MSD could be estimated using the proportion of cine-angiography frames used for the main angle of view relative to the total number of cine-angiography frames and multiplying this by the cumulative ESD. The average MSD (3.0±1.9 Gy) was lower than the average cumulative ESD (4.6±2.6 Gy). This method is an easy way to estimate the MSD during PCI. (authors)

  13. Effect of x-ray low doses on tolerance to salinity in Latuca Sativa plantules

    International Nuclear Information System (INIS)

    Ramirez Fernandez, R.; Gonzalez Nunez, L.M.; Perez Talavera, S.

    1998-01-01

    The work presents the effect of different radiation doses (ranging from 50 to 200 Gy) applied on irradiated lettuce seeds in a ray source for surface therapy, with a working regime of 30 k and 10 m and a dose rate of 12,9 Gy/mins on the germination and growth of plantules in the presence or absence of salinity. The results indicated meaningful differences in the magnitude of the stimulation effect and the doses that caused it for normal conditions, as well as substantial increments in plantules tolerance from irradiated seeds

  14. Change in the alpha criterion policy: variable based on the maximum individual dose function

    International Nuclear Information System (INIS)

    Freitas Acosta Perez, C. de; Sordi, G.M.A.A.

    2006-01-01

    The Alpha value is an extremely important criterion because it determines the time that a country takes to achieve its proposals in order to decrease the workers doses involved with ionizing radiation sources. Currently the countries adopt a single value for alpha based on the annual gross national product, GNP, per capita. The aim of this paper is to show that the selection of a curve for the alpha in place of a single value would be more efficient. This curve would provide alpha values that would will be constraints to the biggest individual doses presented in each optimization process as applied both to designs and to operations. These maximum individual doses would represent the dose distribution among the workers team. To build the curve, the alpha values suggested are not based on the GNP per capita but on a distribution function of the maximum individual doses and on the time necessary to reach the proposal of 1/10 of the annual dose limit foreseen in the sequential optimization processes, that is to reach the region where the individual doses are considered acceptable. So, the differential equations will be - d X/dS =α(H m ax). To clarify our sight about the alpha value we started using the uranium mine example presented in ICRP publication 55, adopting the decision-aiding technique known as extended cost-benefit. for right. Then we used the same example in a hypothetical curve with portions: constant, linear, quadratic and exponential. Eventually we discussed briefly the different shapes of the curves that the alpha value can assume in function of the individual doses. Each of these shapes can correspond to the so called 'risk neutral attitude', 'risk adverse attitude' or 'risk prone attitude' suggested in the appendix B of the ICRP publication 55

  15. Clinical pharmacokinetics of Icotinib, an anti-cancer drug: evaluation of dose proportionality, food effect, and tolerability in healthy subjects.

    Science.gov (United States)

    Liu, Dongyang; Jiang, Ji; Zhang, Li; Tan, Fenlai; Wang, Yingxiang; Zhang, Don; Hu, Pei

    2014-04-01

    Icotinib, an oral epidermal growth factor receptor tyrosine kinase inhibitor, has proved effectiveness in xenografted nude mice. Purpose of the present studies was to investigate tolerability and pharmacokinetics of Icotinib in healthy subjects for the first time, including dose proportionality, food effect, and tolerability. Two studies were conducted in total of 22 healthy subjects: a randomized, two-Latin-square crossover, dose proportional study (n = 12) and a randomized two-way crossover food-effect study (n = 10). Plasma concentration of Icotinib reached peak at a median Tmax of 0.75-3.5 h after single dose and then declined with a mean t1/2β of 6.02-7.83 h. Over the dose range of 100-600 mg, AUC values were proportional to dose and Cmax showed a slight saturation when dose increases. Only 0.2 % of the dose was excreted through kidney in unchanged Icotinib. After dosing 400 mg of Icotinib with high-fat and high-calorie meal, mean Cmax and AUC were significantly increased by 59 and 79 %, respectively. Three subjects experienced four adverse events (rash, increase in AST and ALT, and external injury). Rash and increased levels of AST and ALT were considered as drug-related. No serious adverse events were reported. The current work demonstrated that Icotinib was well tolerated in healthy male subjects (n = 22) over the dose range of 100-600 mg with or without food. Icotinib exposure, expressed in AUC, was proportionally increased with dose over the above dose range. Food intake significantly increased the absorption and exposure of Icotinib in healthy subjects.

  16. The effect of small radiation doses on the rat spinal cord: the concept of partial tolerance

    International Nuclear Information System (INIS)

    Ang, K.K.; Van Der Kogel, A.J.; Van Der Schueren, E.

    1983-01-01

    To evaluate the tolerance of the rat spinal cord to small radiation doses per fraction, an increasing number of fractions is required for induction of paralysis. The assessment of doses of 1-2 Gy, as used in the clinic, would require that over 100 fractions be given. The validity of replacing part of a fractionated irradiation of the spinal cord by a single large dose has been tested. Fractionated irradiation doses with 18 MeV X rays were followed by a ''top-up'' dose of 15 Gy as a single treatment. This is the fraction size of a treatment with two irradiation doses leading to paralysis in 50% of the animals (ED 50). Fractionated treatments were carried out with 2, 5, 10 and 20 fractions followed by the top-up dose of 15 Gy. the isoeffect curve, as a function of the number of fractions, has the same slope as experiments performed without top-up dose. The results show that the quality and quantity of cellular repair is not modified when part of a multifractionated exposure is replaced by a larger top-dose. An important consequence of this finding is, that in treatments with unequal fraction sizes, the partial tolerances can simply be added. Since a top-up dose can replace a sizable number of irradiation treatments, its application will allow investigations of the extent of sublethal damage repair for fraction sizes as low as 1 Gy

  17. SU-F-T-113: Inherent Functional Dependence of Spinal Cord Doses of Variable Irradiated Volumes in Spine SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Ma, L; Braunstein, S; Chiu, J [University of California San Francisco, San Francisco, CA (United States); Sahgal, A [Sunnybrook Health Sciences Center, University of Toronto, Toronto, Ontario (Canada)

    2016-06-15

    Purpose: Spinal cord tolerance for SBRT has been recommended for the maximum point dose level or at irradiated volumes such as 0.35 mL or 10% of contoured volumes. In this study, we investigated an inherent functional relationship that associates these dose surrogates for irradiated spinal cord volumes of up to 3.0 mL. Methods: A hidden variable termed as Effective Dose Radius (EDR) was formulated based on a dose fall-off model to correlate dose at irradiated spinal cord volumes ranging from 0 mL (point maximum) to 3.0 mL. A cohort of 15 spine SBRT cases was randomly selected to derive an EDR-parameterized formula. The mean prescription dose for the studied cases was 21.0±8.0 Gy (range, 10–40Gy) delivered in 3±1 fractions with target volumes of 39.1 ± 70.6 mL. Linear regression and variance analysis were performed for the fitting parameters of variable EDR values. Results: No direct correlation was found between the dose at maximum point and doses at variable spinal cord volumes. For example, Pearson R{sup 2} = 0.643 and R{sup 2}= 0.491 were obtained when correlating the point maximum dose with the spinal cord dose at 1 mL and 3 mL, respectively. However, near perfect correlation (R{sup 2} ≥0.99) was obtained when corresponding parameterized EDRs. Specifically, Pearson R{sup 2}= 0.996 and R{sup 2} = 0.990 were obtained when correlating EDR (maximum point dose) with EDR (dose at 1 mL) and EDR(dose at 3 mL), respectively. As a result, high confidence level look-up tables were established to correlate spinal cord doses at the maximum point to any finite irradiated volumes. Conclusion: An inherent functional relationship was demonstrated for spine SBRT. Such a relationship unifies dose surrogates at variable cord volumes and proves that a single dose surrogate (e.g. point maximum dose) is mathematically sufficient in constraining the overall spinal cord dose tolerance for SBRT.

  18. RBE/absorbed dose relationship of d(50)-Be neutrons determined for early intestinal tolerance in mice

    International Nuclear Information System (INIS)

    Gueulette, J.; Wambersie, A.

    1978-01-01

    RBE/absorbed dose relationship of d(50)-Be neutrons (ref.: 60 Co) was determined using intestinal tolerance in mice (LD50) after single and fractionated irradiation. RBE is 1.8 for a single fraction (about 1000 rad 60 Co dose); it increases when decreasing dose and reaches the plateau value of 2.8 for a 60 Co dose of about 200 rad. This RBE value is used for the clinical applications with the cyclotron 'Cyclone' at Louvain-la-Neuve [fr

  19. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Liebsch, N.J.; O'Farrel, D.; Finkelstein, D.; Efird, J.; Munzenrider, J.E.

    1997-01-01

    Purpose: The aim of this study was to analyze the long-term incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Methods and Materials: Between 1974 and 1995, 367 patients with chordomas (n = 195) and chondrosarcomas (n = 172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. Following 3D treatment planning with delineation of target volumes and critical nontarget structures dose distributions and dose-volume histograms were calculated. Radiotherapy was given an 1.8 Gy or CGE (=Cobalt Gray Equivalent) dose per fraction, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Results: Follow-up time ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem toxicity was observed in 17 of 367 patients attributable to treatment, resulting in death of three patients. Actuarial rates of 5 and 10-year high-grade toxicity-free survival were 94 and 88%, respectively. Increased risk of brainstem toxicity was significantly associated with maximum dose to brainstem, volume of brainstem receiving ≥50 CGE, ≥55 CGE, and ≥60 CGE, number of surgical procedures, and prevalence of diabetes or high blood pressure. Multivariate analysis identified three independent factors as important prognosticators: number of surgical procedures (p < 0.001), volume of the brainstem receiving 60 CGE (p < 0.001), and prevalence of diabetes (p < 0.01). Conclusions: Tolerance of brainstem to fractionated radiotherapy appears to be a steep function of tissue volume included in high dose regions rather than the maximum dose of brainstem alone. In addition, presence of predisposing factors as well as extent of surgical manipulation can significantly lower brainstem tolerance in the individual patient

  20. An accelerated dose escalation with a grass pollen allergoid is safe and well-tolerated: a randomized open label phase II trial.

    Science.gov (United States)

    Chaker, A M; Al-Kadah, B; Luther, U; Neumann, U; Wagenmann, M

    2015-01-01

    The number of injections in the dose escalation of subcutaneous immunotherapy (SCIT) is small for some currently used hypoallergenic allergoids, but can still be inconvenient to patients and can impair compliance. The aim of this trial was to compare safety and tolerability of an accelerated to the conventional dose escalation scheme of a grass pollen allergoid. In an open label phase II trial, 122 patients were 1:1 randomized for SCIT using a grass pollen allergoid with an accelerated dose escalation comprising only 4 weekly injections (Group I) or a conventional dose escalation including 7 weekly injections (Group II). Safety determination included the occurrence of local and systemic adverse events. Tolerability was assessed by patients and physicians. Treatment-related adverse events were observed in 22 (36.1 %) patients in Group I and 15 (24.6 %) in Group II. Local reactions were reported by 18 patients in Group I and 11 in Group II. Five Grade 1 systemic reactions (WAO classification) were observed in Group I and 2 in Group II. Grade 2 reactions occurred 3 times in Group I and 2 times in Group II. Tolerability was rated as "good" or "very good" by 53 (86.9 %) patients in Group I and 59 (100 %) in Group II by investigators. Forty-eight patients in Group I (80.0 %) and 54 in Group II (91.5 %) rated tolerability as "good" or "very good". The dose escalation of a grass pollen allergoid can be accelerated with safety and tolerability profiles comparable to the conventional dose escalation.

  1. ZD0473 pharmacokinetics in Japanese patients: a Phase I dose-escalation study.

    Science.gov (United States)

    Murakami, H; Tamura, T; Yamada, Y; Yamamoto, N; Ueda, Y; Shimoyama, T; Saijo, N

    2002-12-01

    ZD0473 is new platinum agent that was rationally designed to circumvent platinum resistance and reduce the potential for nephro-and neurotoxicity. This Phase I dose-escalating study investigated the pharmacokinetics, tolerability and efficacy of ZD0473 in Japanese patients with solid, refractory tumours. ZD0473 was administered as a 1-h intravenous infusion every 3 weeks. Nine patients received a total of 16 cycles of ZD0473 (median 1 cycle/patient), with 3 patients treated at each of 3 doses (60, 90, 120 mg/m2). The maximum plasma concentration (C(max)) and the area under the concentration-time curve to infinity (AUC(0-infinity)) increased with dose in a linear fashion for both total platinum and ZD0473 in plasma ultrafiltrate, suggesting that the pharmacokinetics of ZD0473 are linear. Haematological and non-haematological toxicities such as nausea and vomiting were mild (grade 1 or 2) and transient. No clinically significant nephro-, oto- or neurotoxicity was observed. Dose-limiting toxicity (DLT) was not observed and the maximum tolerated dose (MTD) was not identified. ZD0473 treatment showed evidence of disease stabilisation in 3 patients (33%). In conclusion, ZD0473 appears to have linear pharmacokinetics, and an acceptable tolerability profile at doses up to 120 mg/m2 in Japanese patients with refractory solid malignancies. Following evaluation of the data from all the Western trials, the ZD0473 development programme changed and this Japanese trial was stopped.

  2. Dose escalation of a curcuminoid formulation

    Directory of Open Access Journals (Sweden)

    Crowell James

    2006-03-01

    Full Text Available Abstract Background Curcumin is the major yellow pigment extracted from turmeric, a commonly-used spice in India and Southeast Asia that has broad anticarcinogenic and cancer chemopreventive potential. However, few systematic studies of curcumin's pharmacology and toxicology in humans have been performed. Methods A dose escalation study was conducted to determine the maximum tolerated dose and safety of a single dose of standardized powder extract, uniformly milled curcumin (C3 Complex™, Sabinsa Corporation. Healthy volunteers were administered escalating doses from 500 to 12,000 mg. Results Seven of twenty-four subjects (30% experienced only minimal toxicity that did not appear to be dose-related. No curcumin was detected in the serum of subjects administered 500, 1,000, 2,000, 4,000, 6,000 or 8,000 mg. Low levels of curcumin were detected in two subjects administered 10,000 or 12,000 mg. Conclusion The tolerance of curcumin in high single oral doses appears to be excellent. Given that achieving systemic bioavailability of curcumin or its metabolites may not be essential for colorectal cancer chemoprevention, these findings warrant further investigation for its utility as a long-term chemopreventive agent.

  3. Safety and tolerability of ibrutinib monotherapy in Japanese patients with relapsed/refractory B cell malignancies.

    Science.gov (United States)

    Tobinai, Kensei; Ogura, Michinori; Ishizawa, Kenichi; Suzuki, Tatsuya; Munakata, Wataru; Uchida, Toshiki; Aoki, Tomohiro; Morishita, Takanobu; Ushijima, Yoko; Takahara, Satoko

    2016-01-01

    In this phase I dose-escalation study we evaluated the safety, tolerability, pharmacokinetics, and antitumor activity of ibrutinib, an oral covalent inhibitor of Bruton's tyrosine kinase (BTK, in Japanese patients with relapsed/refractory B cell malignancies (RRBCM). Fifteen patients aged 42-78 years were enrolled to one of three cohorts. Cohort 1 (n = 3) consisted of two phases, a single-dose (140 and 280 mg) phase and a multiple-dose (420 mg) phase of ibrutinib; cohort 2 (n = 6) included multiple doses of ibrutinib 560 mg; and cohort 3 (n = 6) included only patients with chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL) dosed at ibrutinib 420 mg. One patient (CLL/SLL cohort) experienced grade 3 pneumonia and sepsis, which were considered dose-limiting toxicities. No deaths were reported. The most common (≥ 20% patients) adverse events were neutropenia, anemia, nasopharyngitis, increased bilirubin, and rash. Dose-dependent increase in maximum plasma concentration and area under the concentration from 0 to the last quantifiable time was observed, while time to reach maximum plasma concentration and elimination half-life was similar between doses. The overall response rate was 73.3% (11/15) for all cohorts combined. Overall, ibrutinib (420 and 560 mg) was tolerable with acceptable safety profiles and effective for Japanese patients with RRBCM including CLL/SLL. NCT01704963.

  4. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  5. Efficacy, safety and tolerability of escitalopram in doses up to 50 mg in Major Depressive Disorder (MDD: an open-label, pilot study

    Directory of Open Access Journals (Sweden)

    Crawford Gordon M

    2011-03-01

    Full Text Available Abstract Background Escitalopram is licensed for use at doses up to 20 mg but is used clinically at higher doses. There is limited published data at higher doses and none in the treatment of Major Depressive Disorder (MDD. Methods This open-label, pilot study was designed to investigate the efficacy, safety and tolerability of escitalopram in doses up to 50 mg in MDD. It was conducted in 60 primary care patients with MDD who had not responded to adequate treatment with citalopram. Patients were treated with escalating doses of escitalopram up to 50 mg for up to 32 weeks until they achieved remission (Montgomery-Asberg Depression Rating Scale [MADRS] ≤8 or failed to tolerate the dose. Results Forty-two patients (70% completed the study. Twenty-one patients (35% achieved remission with 8 of the 21 patients (38% needing the 50 mg dose to achieve remission. Median time to remission was 24 weeks and median dose in remission was 30 mg. No significant safety issues were identified although tolerability appeared to decline above a dose of 40 mg with 26% of patients unable to tolerate 50 mg. Twelve (20% patients had adverse events leading to discontinuation. The most common adverse events were headache (35%, nausea, diarrhoea and nasopharyngitis (all 25%. Minor mean weight gain was found during the study, which did not appear to be dose-related. Half of the patients who completed the study chose to continue treatment with escitalopram rather than taper down the dose at 32 weeks. Conclusions Dose escalation with escitalopram above 20 mg may have a useful role in the management of patients with MDD, although further studies are needed to confirm this finding. Trial Registration ClinicalTrials.gov: NCT00785434

  6. Evaluation of preclinical single and multiple dose toxicity and efficacy of 213 Bi-labeled plasminogen activator inhibitor 2 for breast and prostate cancer

    International Nuclear Information System (INIS)

    Rizvi, S.; Li, Y.; Allen, B.; Littlejohn, T.; Ranson, M.; Links, M.; Irving, D.; Andrews, J.

    2003-01-01

    The aim of the study was to evaluate the single and multiple dose toxicity (maximum tolerated dose or MTD) regimes for 213 Bi-labeled PAI2. Dose range of 2-8 mCi/kg was used for the single dose toxicity studies. It was found that end point (20% weight loss and/or distressed behaviour) was not reached for the highest dose either with single or multiple dose injections. For multiple dose toxicity studies, the dose levels ranged between 0.4 - 2 mCi/kg, and were administered daily for 5 days. The highest level tested (2mCi/kg/day x 5) was the maximum tolerated dose as 3/6 mice succumbed to the endpoints. However, histological examination of major organs showed no adverse morphological changes. From these toxicity studies, we concluded that either a dose of 1.6mCi/kg of 213 Bi-PAI2 per day for 5 days or a single injection of 8 mCi/kg can be administered without reaching the endpoints. These dose levels were used for efficacy trials. The efficacy studies were conducted to examine if the 1.6mCi/kgday x 5 multiple dose schedule (sub-maximum tolerated dose) showed efficacy against established and early stage human breast and prostate tumours in mice. Statistical analyses of the data indicate a significant tumour growth rate delay and increased time to reach tumour size endpoint for alpha-PAI2 treatment compared to control tumours, in both pre-tumour stage and established tumour models

  7. Efficacy and Tolerability of Fixed-Dose Combination of Dexketoprofen and Dicyclomine Injection in Acute Renal Colic

    Directory of Open Access Journals (Sweden)

    A. Porwal

    2012-01-01

    Full Text Available Objective. To evaluate the efficacy and tolerability of a fixed-dose combination of dexketoprofen and dicyclomine (DXD injection in patients with acute renal colic. Patients and Methods. Two hundred and seventeen patients were randomized to receive either DXD (n=109 or fixed-dose combination of diclofenac and dicyclomine injection (DLD; n=108, intramuscularly. Pain intensity (PI was self-evaluated by patients on visual analogue scale (VAS at baseline and at 1, 2, 4, 6, and 8 hours. Efficacy parameters were proportion of responders, difference in PI (PID at 8 hours, and sum of analogue of pain intensity differences (SAPID. Tolerability was assessed by patients and physicians. Results. DXD showed superior efficacy in terms of proportion of responders (98.17% versus 81.48; P<0.0001, PID at 8 hours (P=0.002, and SAPID0–8 hours (P=0.004. The clinical global impression for change in pain was significantly better for DXD than DLD. The incidence of adverse events was comparable in both groups. However, global assessment of tolerability was rated significantly better for DXD. Conclusion. DXD showed superior efficacy and tolerability than DLD in patients clinically diagnosed to be suffering from acute renal colic.

  8. Efficacy and Tolerability of Fixed-Dose Combination of Dexketoprofen and Dicyclomine Injection in Acute Renal Colic

    Science.gov (United States)

    Porwal, A.; Mahajan, A. D.; Oswal, D. S.; Erram, S. S.; Sheth, D. N.; Balamurugan, S.; Kamat, V.; Enadle, R. P.; Badadare, A.; Bhatnagar, S. K.; Walvekar, R. S.; Dhorepatil, S.; Naik, R. C.; Basu, I.; Kshirsagar, S. N.; Keny, J. V.; Sengupta, S.

    2012-01-01

    Objective. To evaluate the efficacy and tolerability of a fixed-dose combination of dexketoprofen and dicyclomine (DXD) injection in patients with acute renal colic. Patients and Methods. Two hundred and seventeen patients were randomized to receive either DXD (n = 109) or fixed-dose combination of diclofenac and dicyclomine injection (DLD; n = 108), intramuscularly. Pain intensity (PI) was self-evaluated by patients on visual analogue scale (VAS) at baseline and at 1, 2, 4, 6, and 8 hours. Efficacy parameters were proportion of responders, difference in PI (PID) at 8 hours, and sum of analogue of pain intensity differences (SAPID). Tolerability was assessed by patients and physicians. Results. DXD showed superior efficacy in terms of proportion of responders (98.17% versus 81.48; P < 0.0001), PID at 8 hours (P = 0.002), and SAPID0–8 hours (P = 0.004). The clinical global impression for change in pain was significantly better for DXD than DLD. The incidence of adverse events was comparable in both groups. However, global assessment of tolerability was rated significantly better for DXD. Conclusion. DXD showed superior efficacy and tolerability than DLD in patients clinically diagnosed to be suffering from acute renal colic. PMID:22577544

  9. Radiobiological restrictions and tolerance doses of repeated single-fraction hdr-irradiation of intersecting small liver volumes for recurrent hepatic metastases

    Directory of Open Access Journals (Sweden)

    Wust Peter

    2010-05-01

    Full Text Available Abstract Background To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice. Methods Twenty patients with liver metastases were treated repeatedly (2 - 4 times at identical or intersecting locations by CT-guided interstitial brachytherapy with varying time intervals. Magnetic resonance imaging using the hepatocyte selective contrast media Gd-BOPTA was performed before and after treatment to determine the volume of hepatocyte function loss (called pseudolesion, and the last acquired MRI data set was merged with the dose distributions of all administered brachytherapies. We calculated the BED (biologically equivalent dose for a single dose d = 2 Gy for different α/β values (2, 3, 10, 20, 100 based on the linear-quadratic model and estimated the tolerance dose for liver parenchyma D90 as the BED exposing 90% of the pseudolesion in MRI. Results The tolerance doses D90 after repeated brachytherapy sessions were found between 22 - 24 Gy and proved only slightly dependent on α/β in the clinically relevant range of α/β = 2 - 10 Gy. Variance analysis showed a significant dependency of D90 with respect to the intervals between the first irradiation and the MRI control (p 90 and the pseudolesion's volume. No symptoms of liver dysfunction or other toxic effects such as abscess formation occurred during the follow-up time, neither acute nor on the long-term. Conclusions Inactivation of liver parenchyma occurs at a BED of approx. 22 - 24 Gy corresponding to a single dose of ~10 Gy (α/β ~ 5 Gy. This tolerance dose is consistent with the large potential to treat oligotopic and/or recurrent liver metastases by CT-guided HDR brachytherapy without radiation-induced liver disease (RILD. Repeated small volume irradiation may be applied safely within the limits of this study.

  10. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    Science.gov (United States)

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  11. Normal tissue tolerance to external beam radiation therapy: Peripheral nerves

    International Nuclear Information System (INIS)

    Henriques de Figueiredo, B.; Dejean, C.; Sargos, P.; Kantor, G.; Huchet, A.; Mamou, N.; Loiseau, H.

    2010-01-01

    Plexopathies and peripheral neuropathies appear progressively and with several years delay after radiotherapy. These lesions are observed principally after three clinical situations: supraclavicular and axillar irradiations for breast cancer, pelvic irradiations for various pathologies and limb irradiations for soft tissue sarcomas. Peripheral nerves and plexus (brachial and lumbosacral) are described as serial structures and are supposed to receive less than a given maximum dose linked to the occurrence of late injury. Literature data, mostly ancient, define the maximum tolerable dose to a threshold of 60 Gy and highlight also a great influence of fractionation and high fraction doses. For peripheral nerves, most frequent late effects are pain with significant differences of occurrence between 50 and 60 Gy. At last, associated pathologies (diabetes, vascular pathology, neuropathy) and associated treatments have probably to be taken into account as additional factors, which may increase the risk of these late radiation complications. (authors)

  12. Dose assessment around TR-2 reactor due to maximum credible accident

    International Nuclear Information System (INIS)

    Turgut, M. H.; Adalioglu, U.; Aytekin, A.

    2001-01-01

    The revision of safety analysis report of TR-2 research reactor had been initiated in 1995. The whole accident analysis and accepted scenario for maximum credible accident has been revised according to the new safety concepts and the impact to be given to the environment due to this scenario has been assessed. This paper comprises all results of these calculations. The accepted maximum credible accident scenario is the partial blockage of the whole reactor core which resulted in the release of 25% of the core inventory. The DOSER code which uses very conservative modelling of atmospheric distributions were modified for the assessment calculations. Pasquill conditions based on the local weather observations, topography, and building affects were considered. The thyroid and whole body doses for 16 sectors and up to 10 km of distance around CNAEM were obtained. Release models were puff and a prolonged one of two hours of duration. Release fractions for the active isotopes were chosen from literature which were realistic

  13. A fixed-dose combination tablet of gemigliptin and metformin sustained release has comparable pharmacodynamic, pharmacokinetic, and tolerability profiles to separate tablets in healthy subjects

    Directory of Open Access Journals (Sweden)

    Park SI

    2015-02-01

    Full Text Available Sang-In Park,1,* Howard Lee,1,2,* Jaeseong Oh,1 Kyoung Soo Lim,3 In-Jin Jang,1 Jeong-Ae Kim,4 Jong Hyuk Jung,4 Kyung-Sang Yu1 1Department of Clinical Pharmacology and Therapeutics, Seoul National University College of Medicine and Hospital, Seoul, 2Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Clinical Trials Center, Seoul National University Hospital, Seoul, 3Department of Clinical Pharmacology and Therapeutics, CHA University School of Medicine and CHA Bundang Medical Center, Seongnam, 4LG Life Sciences, Ltd, Seoul, Republic of Korea *These authors contributed equally to this work Background: In type 2 diabetes mellitus, fixed-dose combination (FDC can provide the complementary benefits of correction of multiple pathophysiologic defects such as dysfunctions in glycemic or metabolic control while improving compliance compared with separate tablets taken together. The objective of the study reported here was to compare the pharmacodynamic (PD, pharmacokinetic (PK, and tolerability profiles of gemigliptin and extended-release metformin (metformin XR between FDC and separate tablets.Methods: A randomized, open-label, single-dose, two-way, two-period, crossover study was conducted in 28 healthy male volunteers. Two FDC tablets of gemigliptin/metformin 25/500 mg or separate tablets of gemigliptin (50 mg ×1 and metformin XR (500 mg ×2 were orally administered in each period. Serial blood samples were collected up to 48 hours post-dose to determine dipeptidyl peptidase 4 (DPP-4 activity using spectrophotometric assay and concentrations of gemigliptin and metformin using tandem mass spectrometry. Geometric mean ratios (GMRs of FDC to separate tablet formulations and their 90% confidence intervals (CIs were calculated to compare the PD and PK parameters between the two formulations. Tolerability was assessed throughout the study.Results: The plasma DPP-4 activity

  14. Tolerance to the Diuretic Effects of Cannabinoids and Cross-Tolerance to a κ-Opioid Agonist in THC-Treated Mice.

    Science.gov (United States)

    Chopda, Girish R; Parge, Viraj; Thakur, Ganesh A; Gatley, S John; Makriyannis, Alexandros; Paronis, Carol A

    2016-08-01

    Daily treatment with cannabinoids results in tolerance to many, but not all, of their behavioral and physiologic effects. The present studies investigated the effects of 7-day exposure to 10 mg/kg daily of Δ(9)-tetrahydrocannabinol (THC) on the diuretic and antinociceptive effects of THC and the synthetic cannabinoid AM4054. Comparison studies determined diuretic responses to the κ-opioid agonist U50,488 and furosemide. After determination of control dose-response functions, mice received 10 mg/kg daily of THC for 7 days, and dose-response functions were re-determined 24 hours, 7 days, or 14 days later. THC and AM4054 had biphasic diuretic effects under control conditions with maximum effects of 30 and 35 ml/kg of urine, respectively. In contrast, antinociceptive effects of both drugs increased monotonically with dose to >90% of maximal possible effect. Treatment with THC produced 9- and 7-fold rightward shifts of the diuresis and antinociception dose-response curves for THC and, respectively, 7- and 3-fold rightward shifts in the AM4054 dose-response functions. U50,488 and furosemide increased urine output to >35 ml/kg under control conditions. The effects of U50,488 were attenuated after 7-day treatment with THC, whereas the effects of furosemide were unaltered. Diuretic effects of THC and AM4054 recovered to near-baseline levels within 14 days after stopping daily THC injections, whereas tolerance to the antinociceptive effects persisted longer than 14 days. The tolerance induced by 7-day treatment with THC was accompanied by a 55% decrease in the Bmax value for cannabinoid receptors (CB1). These data indicate that repeated exposure to THC produces similar rightward shifts in the ascending and descending limbs of cannabinoid diuresis dose-effect curves and to antinociceptive effects while resulting in a flattening of the U50,488 diuresis dose-effect function. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  15. Reirradiation tolerance of the rat heart

    International Nuclear Information System (INIS)

    Wondergem, Jan; Ravels, Frank J.M. van; Reijnart, Ivonne W.C.; Strootman, Erwin G.

    1996-01-01

    Purpose: To investigate the influence of reirradiation on the tolerance of the heart after a previous irradiation treatment. Methods and Materials: Female Wistar rats were locally irradiated to the thorax. Development of cardiac function loss was studied with the ex vivo working rat heart preparation. To compare the retreatment experiments, initial, and reirradiation doses were expressed as the percentage of the extrapolated tolerance dose (ETD). Results: Local heart irradiation with a single dose led to a dose-dependent and progressive decrease in cardiac function. The progressive nature of irradiation-induced heart disease is shown to affect the outcome of the retreatment, depending on both the time interval between subsequent doses and the size of the initial dose. The present data demonstrate that hearts are capable of repairing a large part of the initial dose of 10 Gy within the first 24 h. However, once biological damage as a result of the first treatment is fixed, the heart does not show any long-term recovery. At intervals up to 6 months between an initial treatment with 10 Gy and subsequent reirradiation, the reirradiation tolerance dose slightly decreased from 74% of the ETD ref (at 24-h interval) to 68% of the ETD ref (at 6-month interval). Between 6 and 9 months, reirradiation tolerance dose dropped more even to 43% of the ETD ref . Treatment of the heart with an initial dose of 17.5 Gy, instead of 10 Gy, 6 months prior to reirradiation, also led to a further decrease of the reirradiation tolerance dose ( ref ). Conclusions: The outcome of the present study shows a decreased tolerance of the heart to reirradiation at long time intervals (interval > 6 months). This has clinical implications for the estimation of reirradiation tolerance in patients whose mediastinum has to be reirradiated a long time after a first irradiation course

  16. Neutron spectrum and dose-equivalent in shuttle flights during solar maximum

    Energy Technology Data Exchange (ETDEWEB)

    Keith, J E; Badhwar, G D; Lindstrom, D J [National Aeronautics and Space Administration, Houston, TX (United States). Lyndon B. Johnson Space Center

    1992-01-01

    This paper presents unambiguous measurements of the spectrum of neutrons found in spacecraft during spaceflight. The neutron spectrum was measured from thermal energies to about 10 MeV using a completely passive system of metal foils as neutron detectors. These foils were exposed to the neutron flux bare, covered by thermal neutron absorbers (Gd) and inside moderators (Bonner spheres). This set of detectors was flown on three U.S. Space Shuttle flights, STS-28, STS-36 and STS-31, during the solar maximum. We show that the measurements of the radioactivity of these foils lead to a differential neutron energy spectrum in all three flights that can be represented by a power law, J(E){approx equal}E{sup -0.765} neutrons cm{sup -2} day {sup -1} MeV{sup -1}. We also show that the measurements are even better represented by a linear combination of the terrestrial neutron albedo and a spectrum of neutrons locally produced in a aluminium by protons, computed by a previous author. We use both approximations to the neutron spectrum to produce a worst case and most probable case for the neutron spectra and the resulting dose-equivalents, computed using ICRP-51 neutron fluence-dose conversion tables. We compare these to the skin dose-equivalents due to charged particles during the same flights. (author).

  17. IDEAL-CRT: A Phase 1/2 Trial of Isotoxic Dose-Escalated Radiation Therapy and Concurrent Chemotherapy in Patients With Stage II/III Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Landau, David B., E-mail: david.landau@kcl.ac.uk [Guy' s & St. Thomas' NHS Trust, King' s College London, London (United Kingdom); Hughes, Laura [Cancer Research UK and UCL Cancer Trials Centre, London (United Kingdom); Baker, Angela [Clatterbridge Cancer Centre, Bebington (United Kingdom); Bates, Andrew T. [Southampton General Hospital, Southampton (United Kingdom); Bayne, Michael C. [Poole Hospital, Poole (United Kingdom); Counsell, Nicholas [Cancer Research UK and UCL Cancer Trials Centre, London (United Kingdom); Garcia-Alonso, Angel [North Wales Cancer Centre, Rhyl (United Kingdom); Harden, Susan V. [Addenbrookes Hospital, Cambridge (United Kingdom); Hicks, Jonathan D. [Beatson West of Scotland Cancer Centre, Glasgow (United Kingdom); Hughes, Simon R. [Guy' s & St. Thomas' NHS Trust, King' s College London, London (United Kingdom); Illsley, Marianne C. [Royal Surrey County Hospital, Guilford (United Kingdom); Khan, Iftekhar [Cancer Research UK and UCL Cancer Trials Centre, London (United Kingdom); Laurence, Virginia [Poole Hospital, Poole (United Kingdom); Malik, Zafar; Mayles, Helen; Mayles, William Philip M. [Clatterbridge Cancer Centre, Bebington (United Kingdom); Miles, Elizabeth [Mount Vernon Hospital, Middlesex (United Kingdom); Mohammed, Nazia [Beatson West of Scotland Cancer Centre, Glasgow (United Kingdom); Ngai, Yenting [Cancer Research UK and UCL Cancer Trials Centre, London (United Kingdom); Parsons, Emma [Mount Vernon Hospital, Middlesex (United Kingdom); and others

    2016-08-01

    Purpose: To report toxicity and early survival data for IDEAL-CRT, a trial of dose-escalated concurrent chemoradiotherapy (CRT) for non-small cell lung cancer. Patients and Methods: Patients received tumor doses of 63 to 73 Gy in 30 once-daily fractions over 6 weeks with 2 concurrent cycles of cisplatin and vinorelbine. They were assigned to 1 of 2 groups according to esophageal dose. In group 1, tumor doses were determined by an experimental constraint on maximum esophageal dose, which was escalated following a 6 + 6 design from 65 Gy through 68 Gy to 71 Gy, allowing an esophageal maximum tolerated dose to be determined from early and late toxicities. Tumor doses for group 2 patients were determined by other tissue constraints, often lung. Overall survival, progression-free survival, tumor response, and toxicity were evaluated for both groups combined. Results: Eight centers recruited 84 patients: 13, 12, and 10, respectively, in the 65-Gy, 68-Gy, and 71-Gy cohorts of group 1; and 49 in group 2. The mean prescribed tumor dose was 67.7 Gy. Five grade 3 esophagitis and 3 grade 3 pneumonitis events were observed across both groups. After 1 fatal esophageal perforation in the 71-Gy cohort, 68 Gy was declared the esophageal maximum tolerated dose. With a median follow-up of 35 months, median overall survival was 36.9 months, and overall survival and progression-free survival were 87.8% and 72.0%, respectively, at 1 year and 68.0% and 48.5% at 2 years. Conclusions: IDEAL-CRT achieved significant treatment intensification with acceptable toxicity and promising survival. The isotoxic design allowed the esophageal maximum tolerated dose to be identified from relatively few patients.

  18. A Phase I Trial of High-Dose Lenalidomide and Melphalan as Conditioning for Autologous Stem Cell Transplantation in Relapsed or Refractory Multiple Myeloma.

    Science.gov (United States)

    Mark, Tomer M; Guarneri, Danielle; Forsberg, Peter; Rossi, Adriana; Pearse, Roger; Perry, Arthur; Pekle, Karen; Tegnestam, Linda; Greenberg, June; Shore, Tsiporah; Gergis, Usama; Mayer, Sebastian; Van Besien, Koen; Ely, Scott; Jayabalan, David; Sherbenou, Daniel; Coleman, Morton; Niesvizky, Ruben

    2017-06-01

    Autologous stem cell transplantation (ASCT) conditioned with high-dose chemotherapy has long been established as the standard of care for eligible patients with newly diagnosed multiple myeloma. Despite recent therapeutic advances, high-dose melphalan (HDM) remains the chemotherapy regimen of choice in this setting. Lenalidomide (LEN) in combination with low-dose dexamethasone is recognized as a standard of care for patients with relapsed or refractory multiple myeloma (RRMM), and there is growing support for the administration of LEN as maintenance therapy post-ASCT. In view of the above, the present phase I clinical trial was designed to evaluate the safety and tolerability of high-dose LEN (HDLEN) in patients with RRMM, and to determine the maximum tolerated dose of HDLEN when added to HDM before ASCT. Despite administering HDLEN at doses of up to 350 mg/day, the maximum tolerated dose could not be determined, owing to an insufficient number of dose-limiting toxicities in the 21 patients enrolled in the trial. Conditioning with HDLEN plus HDM was associated with a favorable tolerability profile. Adverse events following ASCT were as expected with HDM. Median progression-free and overall survival were 10 months and 22 months, respectively, in this population of heavily pretreated patients. Our findings suggest that HDLEN in combination with HDM may offer significant potential as a conditioning regimen before ASCT in patients with RRMM. These preliminary findings are now being evaluated further in an ongoing phase II clinical trial. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  19. Dose-volume complication analysis for visual pathway structures of patients with advanced paranasal sinus tumors

    International Nuclear Information System (INIS)

    Martel, Mary Kaye; Sandler, Howard M.; Cornblath, Wayne T.; Marsh, Lon H.; Hazuka, Mark B.; Roa, Wilson H.; Fraass, Benedict A.; Lichter, Allen S.

    1997-01-01

    Purpose: The purpose of the present work was to relate dose and volume information to complication data for visual pathway structures in patients with advanced paranasal sinus tumors. Methods and Materials: Three-dimensional (3D) dose distributions for chiasm, optic nerve, and retina were calculated and analyzed for 20 patients with advanced paranasal sinus malignant tumors. 3D treatment planning with beam's eye view capability was used to design beam and block arrangements, striving to spare the contralateral orbit (to lessen the chance of unilateral blindness) and frequently the ipsilateral orbit (to help prevent bilateral blindness). Point doses, dose-volume histogram analysis, and normal tissue complication probability (NTCP) calculations were performed. Published tolerance doses that indicate significant risk of complications were used as guidelines for analysis of the 3D dose distributions. Results: Point doses, percent volume exceeding a specified published tolerance dose, and NTCP calculations are given in detail for patients with complications versus patients without complications. Two optic nerves receiving maximum doses below the published tolerance dose sustained damage (mild vision loss). Three patients (of 13) without optic nerve sparing and/or chiasm sparing had moderate or severe vision loss. Complication data, including individual patient analysis to estimate overall risk for loss of vision, are given. Conclusion: 3D treatment planning techniques were used successfully to provide bilateral sparing of the globe for most patients. It was more difficult to spare the optic nerves, especially on the ipsilateral side, when prescription dose exceeded the normal tissue tolerance doses. NTCP calculations may be useful in assessing complication risk better than point dose tolerance criteria for the chiasm, optic nerve, and retina. It is important to assess the overall risk of blindness for the patient in addition to the risk for individual visual pathway

  20. Early Mucosal Reactions During and After Head-and-Neck Radiotherapy: Dependence of Treatment Tolerance on Radiation Dose and Schedule Duration

    International Nuclear Information System (INIS)

    Fenwick, John D.; Lawrence, Geoff P.; Malik, Zafar; Nahum, Alan E.; Mayles, W. Philip M.

    2008-01-01

    Purpose: To more precisely localize the dose-time boundary between head-and-neck radiotherapy schedules inducing tolerable and intolerable early mucosal reactions. Methods and Materials: Total cell-kill biologically effective doses (BED CK ) have been calculated for 84 schedules, including incomplete repair effects, but making no other corrections for the effect of schedule duration T. [BED CK ,T] scatterplots are graphed, overlying BED CKboundary (T) curves on the plots and using discriminant analysis to optimize BED CKboundary (T) to best represent the boundary between the tolerable and intolerable schedules. Results: More overlap than expected is seen between the tolerable and intolerable treatments in the 84-schedule [BED CK ,T] scatterplot, but this was largely eliminated by removing gap and tolerated accelerating schedules from the plot. For the remaining 57 predominantly regular schedules, the BED CKboundary (T) boundary increases with increasing T (p = 0.0001), curving upwards significantly nonlinearly (p = 0.00007) and continuing to curve beyond 15 days (p = 0.035). The regular schedule BED CKboundary (T) boundary does not describe tolerability well for accelerating schedules (p = 0.002), with several tolerated accelerating schedules lying above the boundary where regular schedules would be intolerable. Gap schedule tolerability also is not adequately described by the regular schedule boundary (p = 0.04), although no systematic offset exists between the regular boundary and the overall gap schedule tolerability pattern. Conclusions: All schedules analyzed (regular, gap, and accelerating) with BED CK values below BED CKboundary (T)=69.5x(T/32.2)/sin((T/32.2) (radians) )-3.5Gy 10 (forT≤50 days) are tolerable, and many lying above the boundary are intolerable. The accelerating schedules analyzed were tolerated better overall than are the regular schedules with similar [BED CK ,T] values.

  1. Short-term digestive tolerance of different doses of NUTRIOSE®FB, a food dextrin, in adult men

    NARCIS (Netherlands)

    Heuvel, E.G.H.M. van den; Wils, D.; Pasman, W.J.; Bakker, M.; Saniez, M.-H.; Kardinaal, A.F.M.

    2004-01-01

    Objective: To determine the tolerance of increasing dosages of an incompletely hydrolysed and/or incompletely absorbed food dextrin coming from wheat starch, NUTRIOSE®FB, at daily levels of 10 and 15 g up to 60 and 80 g, respectively. Design: A randomized, double-blind, multiple dose,

  2. Similar efficacy and tolerability of double-dose chloroquine and artemether-lumefantrine for treatment of Plasmodium falciparum infection in Guinea-Bissau: a randomized trial

    DEFF Research Database (Denmark)

    Ursing, Johan; Kofoed, Poul-Erik; Rodrigues, Amabelia

    2011-01-01

    In 2008, Guinea-Bissau introduced artemether-lumefantrine for treatment of uncomplicated malaria. Previously, 3 times the standard dose of chloroquine, that was probably efficacious against Plasmodium falciparum with the resistance-associated chloroquine-resistance transporter (pfcrt) 76T allele,......, was routinely used. The present study compared the efficacy and tolerability of a double standard dose of chloroquine with the efficacy and tolerability of artemether-lumefantrine.......In 2008, Guinea-Bissau introduced artemether-lumefantrine for treatment of uncomplicated malaria. Previously, 3 times the standard dose of chloroquine, that was probably efficacious against Plasmodium falciparum with the resistance-associated chloroquine-resistance transporter (pfcrt) 76T allele...

  3. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Munzenrider, J.E.; Liebsch, N.J.; O'Farrell, D.; Efird, J.; Daly, W.; Suit, H.D.

    1996-01-01

    Purpose/Objective: Brainstem tolerance to inhomogenous radiation doses applied by modern conformal radiotherapy has not yet been examined. The aim of this study was to analyse the incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Materials and Methods: Between 1974 and 1995, 367 patients with chordomas (n=195) and chondrosarcomas (n=172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. All patients had previously undergone biopsy, subtotal or total tumor removal. 104 patients had two or more surgical procedures before radiotherapy. Following 3D treatment planning with delineation of target volumes and critical non-target structures, dose distributions and dose volume histograms were calculated [at the time of treatment delivery]. Radiotherapy was given once a day, 1.8 Gy or CGE (Cobalt Gy Equivalent: Proton Gy X 1.1) per fraction, 5 fractions per week, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Dose distributions were developed to limit dose to brainstem surface and center; current plans limit dose to surface and center to ≤64 CGE and ≤53 CGE, respectively. Brainstem toxicity was scored according to the RTOG grading system. Results: Follow-up ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem symptoms, attributable to the treatment, developed in 17 of 282 patients with local tumor control (6.0%), resulting in death of three patients. The mean time to onset of symptoms was 17 months (range: 4.5 to 177 months). These symptoms appeared in 89.5% within 3 years. Grading of the brainstem toxicity is listed in table 1. Actuarial rates of 5 and 10 year toxicity free survival were 87% and 82% respectively. Increased risk of brainstem toxicity was significantly associated with maximum brainstem dose

  4. Radiation therapy and concurrent fixed dose amifostine with escalating doses of twice-weekly gemcitabine in advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Yavuz, A. Aydin; Aydin, Fazil; Yavuz, Melek N.; Ilis, Esra; Ozdemir, Feyyaz

    2001-01-01

    Purpose: To determine the maximum tolerated dose (MTD) and dose-limiting toxicity (DLT) of twice-weekly gemcitabine (TW-G) when administered in conjunction with fixed dose amifostine (A) during external radiotherapy (RT) in patients with advanced pancreatic cancer. Methods and Materials: Ten patients with previously untreated, locally advanced, or asymptomatic-metastatic pancreatic adenocarcinoma were enrolled in this study. RT was delivered by using the standard four-field technique (1.8 Gy daily fractions, 45 Gy followed by a boost of 5.4 Gy, in 5-1/2 weeks). The starting dose of TW-G was 60 mg/m 2 (i.v., 30-min infusion), which is equal to the upper limit of previously reported MTD of TW-G when given without A during RT. A was given just before the TW-G, at a fixed dose of 340 mg/m 2 (i.v., rapid infusion). TW-G doses were escalated by 30-mg/m 2 increments in successive cohorts of 3 to 6 additional patients until DLT was observed. Toxicities were graded using the Radiation Therapy Oncology Group and National Cancer Institute Common Toxicity Criteria, version 2.0. Results: In general, therapy was well tolerated in patients treated at the first two dose levels of 60 mg/m 2 and 90 mg/m 2 . The DLT of TW-G given in conjunction with A during RT were neutropenia, thrombocytopenia, and nausea/vomiting at the dose level of 120 mg/m 2 . Of the 10 patients eligible for a median follow-up of 10 months, 5 remain alive; 1 complete responder, 3 partial responders, and 1 with stable disease. Conclusion: A dose of TW-G at a level of 90 mg/m 2 produced tolerable toxicity and it may possess significant activity when delivered in conjunction with 340 mg/m 2 dose of A during RT of the upper abdomen. Due to the higher MTD of TW-G seen in our study, we consider that the A supplementation may optimize the therapeutic index of TW-G-based chemoradiotherapy protocols in patients with pancreatic carcinoma

  5. Pegylated Long-Acting Human Growth Hormone Possesses a Promising Once-Weekly Treatment Profile, and Multiple Dosing Is Well Tolerated in Adult Patients with Growth Hormone Deficiency

    DEFF Research Database (Denmark)

    Søndergaard, Esben; Klose, Marianne Christina; Hansen, Mette

    2011-01-01

    Background: Recombinant human GH (rhGH) replacement therapy in children and adults currently requires daily sc injections for several years or lifelong, which may be both inconvenient and distressing for patients. NNC126-0083 is a pegylated rhGH developed for once-weekly administration. Objectives......: Our objective was to evaluate the safety, tolerability, pharmacokinetics, and pharmacodynamics of multiple doses of NNC126-0083 in adult patients with GH deficiency (GHD). Subjects and Methods: Thirty-three adult patients with GHD, age 20-65 yr, body mass index 18.5-35.0 kg/m(2), and glycated...... to 240 h after the third dosing. Physical examination, antibodies, and local tolerability were assessed. Results: NNC126-0083 was well tolerated with no difference in local tolerability compared with placebo and with no signs of lipoatrophy. A more than dose-proportional exposure was observed...

  6. Repeated dose studies with pure Epigallocatechin-3-gallate demonstrated dose and route dependant hepatotoxicity with associated dyslipidemia.

    Science.gov (United States)

    Ramachandran, Balaji; Jayavelu, Subramani; Murhekar, Kanchan; Rajkumar, Thangarajan

    2016-01-01

    EGCG (Epigallocatechin-3-gallate) is the major active principle catechin found in green tea. Skepticism regarding the safety of consuming EGCG is gaining attention, despite the fact that it is widely being touted for its potential health benefits, including anti-cancer properties. The lack of scientific data on safe dose levels of pure EGCG is of concern, while EGCG has been commonly studied as a component of GTE (Green tea extract) and not as a single active constituent. This study has been carried out to estimate the maximum tolerated non-toxic dose of pure EGCG and to identify the treatment related risk factors. In a fourteen day consecutive treatment, two different administration modalities were compared, offering an improved [i.p (intraperitoneal)] and limited [p.o (oral)] bioavailability. A trend of dose and route dependant hepatotoxicity was observed particularly with i.p treatment and EGCG increased serum lipid profile in parallel to hepatotoxicity. Fourteen day tolerable dose of EGCG was established as 21.1 mg/kg for i.p and 67.8 mg/kg for p.o. We also observed that, EGCG induced effects by both treatment routes are reversible, subsequent to an observation period for further fourteen days after cessation of treatment. It was demonstrated that the severity of EGCG induced toxicity appears to be a function of dose, route of administration and period of treatment.

  7. Single- and multiple-dose pharmacokinetics and absolute bioavailability of tedizolid.

    Science.gov (United States)

    Flanagan, Shawn; Fang, Edward; Muñoz, Kelly A; Minassian, Sonia L; Prokocimer, Philippe G

    2014-09-01

    Tedizolid phosphate is a novel antibacterial under investigation for the treatment of gram-positive infections. This study was conducted to assess the pharmacokinetics, safety, and tolerability of intravenous tedizolid phosphate as well as the oral bioavailability of tedizolid phosphate. Double-blind, single-ascending dose, multiple-dose pharmacokinetics study, as well as tolerability and open-label crossover studies. Single center in the United States (Covance Clinical Research Unit, Madison, WI) between September 2009 and January 2010. Ninety healthy volunteers. Single intravenous (IV) doses of tedizolid phosphate 50 mg (lead-in) and 100-400 mg. Single oral and IV dose of tedizolid phosphate 200 mg in crossover fashion. Multiple IV doses of tedizolid phosphate 200 and 300 mg for up to 7 days. A dose-dependent increase was observed in the maximum plasma concentration (1.2-5.1 μg/ml) and the area under the concentration-time curve (17.4-58.7 μg × hr/ml) of tedizolid (the microbiologically active moiety of tedizolid phosphate) after single IV doses of tedizolid phosphate 100-400 mg. Administration of IV tedizolid phosphate 200 mg once/day for 7 days resulted in minimal (28%) tedizolid accumulation. The absolute oral bioavailability of tedizolid after a single 200-mg dose of tedizolid phosphate was 91%; pharmacokinetic parameters of tedizolid were similar with oral and IV administration. Treatment-related adverse events occurred in 41% of subjects. Most adverse events were related to infusion site and became more frequent with multiple dosing. In an additional 3-day tolerability study, IV tedizolid phosphate 200 mg and placebo were similarly tolerated, based on visual infusion phlebitis scores. These results from a population of healthy volunteers support once/day dosing of tedizolid phosphate 200 mg with both the oral and IV formulations, without the need for dose adjustment when switching administration routes. © 2014 Cubist Pharmaceuticals. Pharmacotherapy

  8. In vivo assessment of the gastric mucosal tolerance dose after single fraction, small volume irradiation of liver malignancies by computed tomography-guided, high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Streitparth, Florian; Pech, Maciej; Boehmig, Michael; Ruehl, Ricarda; Peters, Nils; Wieners, Gero; Steinberg, Johannes; Lopez-Haenninen, Enrique; Felix, Roland; Wust, Peter; Ricke, Jens

    2006-01-01

    Purpose: The aim of this study was to assess the tolerance dose of gastric mucosa for single-fraction computed tomography (CT)-guided, high-dose-rate (HDR) brachytherapy of liver malignancies. Methods and Materials: A total of 33 patients treated by CT-guided HDR brachytherapy of liver malignancies in segments II and/or III were included. Dose planning was performed upon a three-dimensional CT data set acquired after percutaneous applicator positioning. All patients received gastric protection post-treatment. For further analysis, the contours of the gastric wall were defined in every CT slice using Brachyvision Software. Dose-volume histograms were calculated for each treatment and correlated with clinical data derived from questionnaires assessing Common Toxicity Criteria (CTC). All patients presenting symptoms of upper GI toxicity were examined endoscopically. Results: Summarizing all patients the minimum dose applied to 1 ml of the gastric wall (D 1ml ) ranged from 6.3 to 34.2 Gy; median, 14.3 Gy. Toxicity was present in 18 patients (55%). We found nausea in 16 (69%), emesis in 9 (27%), cramping in 13 (39%), weight loss in 12 (36%), gastritis in 4 (12%), and ulceration in 5 patients (15%). We found a threshold dose D 1ml of 11 Gy for general gastric toxicity and 15.5 Gy for gastric ulceration verified by an univariate analysis (p = 0.01). Conclusions: For a single fraction, small volume irradiation we found in the upper abdomen a threshold dose D 1ml of 15.5 Gy for the clinical endpoint ulceration of the gastric mucosa. This in vivo assessment is in accordance with previously published tolerance data

  9. Liposomal bupivacaine as a single-injection peripheral nerve block: a dose-response study.

    Science.gov (United States)

    Ilfeld, Brian M; Malhotra, Nisha; Furnish, Timothy J; Donohue, Michael C; Madison, Sarah J

    2013-11-01

    Currently available local anesthetics approved for single-injection peripheral nerve blocks have a maximum duration of fashion. The end points included the maximum voluntary isometric contraction (MVIC) of the quadriceps femoris muscle and tolerance to cutaneous electrical current in the femoral nerve distribution. Measurements were performed from baseline until quadriceps MVIC returned to 80% of baseline bilaterally. There were statistically significant dose responses in MVIC (0.09%/mg, SE = 0.03, 95% confidence interval [CI], 0.04-0.14, P = 0.002) and tolerance to cutaneous current (-0.03 mA/mg, SE = 0.01, 95% CI, -0.04 to -0.02, P 40 mg, tolerance to cutaneous current did not return to within 20% above baseline until after 24 hours in 100% of subjects (95% CI, 56%-100%). MVIC did not consistently return to within 20% of baseline until after 24 hours in 90% of subjects (95% CI, 54%-100%). Motor block duration was not correlated with bupivacaine dose (0.06 hour/mg, SE = 0.14, 95% CI, -0.27 to 0.39, P = 0.707). The results of this investigation suggest that deposition of a liposomal bupivacaine formulation adjacent to the femoral nerve results in a partial sensory and motor block of >24 hours for the highest doses examined. However, the high variability of block magnitude among subjects and inverse relationship of dose and response magnitude attests to the need for a phase 3 study with a far larger sample size, and that these results should be viewed as suggestive, requiring confirmation in a future trial.

  10. Repeated dose studies with pure Epigallocatechin-3-gallate demonstrated dose and route dependant hepatotoxicity with associated dyslipidemia

    Directory of Open Access Journals (Sweden)

    Balaji Ramachandran

    Full Text Available EGCG (Epigallocatechin-3-gallate is the major active principle catechin found in green tea. Skepticism regarding the safety of consuming EGCG is gaining attention, despite the fact that it is widely being touted for its potential health benefits, including anti-cancer properties. The lack of scientific data on safe dose levels of pure EGCG is of concern, while EGCG has been commonly studied as a component of GTE (Green tea extract and not as a single active constituent. This study has been carried out to estimate the maximum tolerated non-toxic dose of pure EGCG and to identify the treatment related risk factors. In a fourteen day consecutive treatment, two different administration modalities were compared, offering an improved [i.p (intraperitoneal] and limited [p.o (oral] bioavailability. A trend of dose and route dependant hepatotoxicity was observed particularly with i.p treatment and EGCG increased serum lipid profile in parallel to hepatotoxicity. Fourteen day tolerable dose of EGCG was established as 21.1 mg/kg for i.p and 67.8 mg/kg for p.o. We also observed that, EGCG induced effects by both treatment routes are reversible, subsequent to an observation period for further fourteen days after cessation of treatment. It was demonstrated that the severity of EGCG induced toxicity appears to be a function of dose, route of administration and period of treatment. Keywords: EGCG, Green tea, Serum lipids, Dose dependant toxicity, Route dependant toxicity, Liver toxicity, Dyslipidemia

  11. Spinal cord tolerance to single-session uniform irradiation in pigs: Implications for a dose-volume effect

    International Nuclear Information System (INIS)

    Medin, Paul M.; Foster, Ryan D.; Kogel, Albert J. van der; Sayre, James W.; McBride, William H.; Solberg, Timothy D.

    2013-01-01

    Background and purpose: This study was performed to test the hypothesis that spinal cord radiosensitivity is significantly modified by uniform versus laterally non-uniform dose distributions. Materials and methods: A uniform dose distribution was delivered to a 4.5–7.0 cm length of cervical spinal cord in 22 mature Yucatan minipigs for comparison with a companion study in which a laterally non-uniform dose was given [1]. Pigs were allocated into four dose groups with mean maximum spinal cord doses of 17.5 ± 0.1 Gy (n = 7), 19.5 ± 0.2 Gy (n = 6), 22.0 ± 0.1 Gy (n = 5), and 24.1 ± 0.2 Gy (n = 4). The study endpoint was motor neurologic deficit determined by a change in gait within one year. Spinal cord sections were stained with a Luxol fast blue/periodic acid Schiff combination. Results: Dose–response curves for uniform versus non-uniform spinal cord irradiation were nearly identical with ED 50 ’s (95% confidence interval) of 20.2 Gy (19.1–25.8) and 20.0 Gy (18.3–21.7), respectively. No neurologic change was observed for either dose distribution when the maximum spinal cord dose was ⩽17.8 Gy while all animals experienced deficits at doses ⩾21.8 Gy. Conclusion: No dose-volume effect was observed in pigs for the dose distributions studied and the endpoint of motor neurologic deficit; however, partial spinal cord irradiation resulted in less debilitating neurologic morbidity and histopathology

  12. Anthropomorphic chest phantom imaging – The potential for dose creep in computed radiography

    International Nuclear Information System (INIS)

    Ma, W.K.; Hogg, P.; Tootell, A.; Manning, D.; Thomas, N.; Kane, T.; Kelly, J.; McKenzie, M.; Kitching, J.

    2013-01-01

    For film-based radiography the operator had to be exact in the selection of acquisition parameters or the image could easily become under- or over-exposed. By contrast, digital technology allows for a much greater tolerance of acquisition factor selection which would still give an image of acceptable diagnostic quality. In turn this greater tolerance allows for the operator to increase effective dose for little or no penalty in image quality. The purpose of this article is to determine how image quality and lesion visibility vary with effective dose (E) in order to identify how much overexposure could be tolerated within the radiograph. Using an anthropomorphic chest phantom with ground glass lesions we determined how perceptual image quality and E varied over a wide range of acquisition conditions. Perceptual image quality comprised of image quality and lesion visibility. E was calculated using Monte Carlo method; image quality was determined using a two alternative forced choice (2AFC) method and the quality criteria were partly informed from European guidelines. Five clinicians with significant experience in image reading scored the images for quality (intraclass correlation coefficient 0.869). Image quality and lesion visibility had a close correlation (R 2 > 0.8). The tolerance for over-exposure, whilst still acquiring an image of acceptable quality, increases with decreasing kV and increasing source to image distance (SID). The maximum over-exposure factor (ratio of maximum E to minimum E that produce images of acceptable quality) possible was 139 (at 125 cm and 60 kV). Given the phantom had characteristics similar to the human thorax we propose that that potential for overexposure in a human whilst still obtaining an image of acceptable perceptual image quality is very high. Further research into overexposure tolerance and dose creep should be undertaken

  13. Effect of low dose of X rays about the tolerance to the salinity and the agricultural yield in cultivations of economic importance for Cuba

    International Nuclear Information System (INIS)

    Ramirez Fernandez, Ramiro; Gonzalez Nunnez, Luis Manuel; Garcia Rodriguez, Blanca; Licea Castro, Luis; Porras Leon, Elia

    1999-01-01

    The effect of low dose of X rays on rice and lettuce plant salt tolerance and on the agricultural yield in plants of cucumber and tomato was studied. The results showed a meaningful increase in the tolerance of the plants to salt stress in both crops for some of the applied dose and were determined the better doses for the increment of the crop yield of the studied varieties. Also was carried out an analysis of regression that showed a high correlation between the variables of the growth and the agricultural yield and on this base it is discussed the possibility of selecting the stimulant dose range during the early plants growth stages

  14. Influence of Routine MV CBCT Usage on Dose Distribution in Pelvic Radiotherapy

    International Nuclear Information System (INIS)

    Faj, D.; Kasabasic, M.; Ivkovic, A.; Tomas, I.; Jurkovic, S.

    2013-01-01

    The pelvic radiotherapy is a standard treatment for patients with cervical, uterine and rectal carcinomas. During radiation treatment open tabletop device or bellyboard is used to reduce the side effects of healthy surrounding tissue. Patients are continually adjusting to the bellyboard during the treatment which causes geometrical and dosage uncertainties and influences the results of the treatment. Therefore, to reduce these uncertainties, megavoltage cone-beam computed tomography (MV CBCT) system is used. The objective of this research was to evaluate the image acquisition dose delivered to patients from MV CBCT. MV CBCT imaging was simulated on 15 patients using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The influence of the routine MV CBCT usage on treatment plan was investigated by analyzing the changes in dose volume histograms, mean values and maximum doses in the planning volumes. Simulations have shown that daily usage of MV CBCT causes differences in the dose volume histograms. Moreover, for every patient mean value exceeded prescribed tolerance (±1% of the prescribed dose) and maximum value exceeded recommended maximum of 107% of the prescribed dose. The results have shown that MV CBCT dose to the patient should be a part of the RT plan.(author)

  15. Effects of first-dose volume and exercise on the efficacy and tolerability of bowel preparations for colonoscopy in Chinese people

    Directory of Open Access Journals (Sweden)

    Qin Y

    2016-04-01

    Full Text Available Ying Qin, Wei Liu, Songbai Lin, Xiangfeng Li International Medical Services, Peking Union Medical College Hospital, Beijing, People’s Republic of China Aim: This study was designed to compare the efficacy and tolerability of bowel preparations with and without the higher first-dose volume of polyethylene glycol (PEG solution or exercise after drinking PEG solution in Chinese people. Methods: A total of 330 participants who had a colonoscopy done in Peking Union Medical College Hospital were randomly and evenly assigned to three groups. Participants in Group A ingested 1 L PEG solution and then ingested 2 L PEG solution at a rate of 250 mL every 15 minutes. Participants in Group B ingested 3 L PEG solution at a rate of 250 mL every 15 minutes and then exercised more than 10 minutes after ingesting each liter of PEG solution. Participants in Group C ingested 3 L PEG solution at a rate of 250 mL every 15 minutes. Experienced gastrointestinal endoscopists rated the efficacy of bowel preparations based on the Boston Bowel Preparation Scale score. A questionnaire regarding participants’ symptoms associated with bowel preparations was administered to evaluate participants’ tolerability. Results: The three groups had insignificant difference in the percentages of participants’ symptoms including dizziness, nausea, stomach ache, bloating, and asthenia. However, the percentages of participants having hunger sensation, sleep disturbance, and anal discomfort were significantly higher in groups with the higher first-dose volume of PEG solution or exercise after drinking PEG solution than without them. The three groups had insignificant difference in the Boston Bowel Preparation Scale score. Conclusion: Whether to add the higher first-dose volume of PEG solution and exercise after drinking PEG solution or not, all participants achieved a similar quality of bowel preparations. Bowel preparations without the additional first-dose volume of PEG

  16. High lenticular tolerance to ultraviolet radiation-B by pigmented guinea-pig; application of a safety limit strategy for UVR-induced cataract.

    Science.gov (United States)

    Mody, Vino C; Kakar, Manoj; Söderberg, Per G; Löfgren, Stefan

    2012-05-01

    The purpose of this study was to determine a threshold measure, maximum tolerable dose (MTD), for avoidance of UVR-B-induced cataract in the pigmented guinea-pig. Thirty pupil-dilated anesthetized young female guinea-pigs, divided into five equal groups, received between 0 and 84.9 kJ/m(2) unilateral UVR-B. Lens extraction and in vitro lens photography occurred 24 hr after exposure. Measurement of intensity of lens light scattering served as quantifying tool for the degree of cataract. Data analysis included regression, using a second order polynomial model. The applied MTD concept was based on the UVR-B dose-response curve obtained for the pigmented guinea-pig. A smaller number of pigmented guinea-pigs, pigmented rats and albino rats underwent morphometric analysis of the anterior segment geometry. All eyes exposed to UVR-B developed cataract in the anterior subcapsular region. MTD for avoidance of UVR-B-induced cataract was 69.0 kJ/m(2) in the pigmented guinea-pig. Iris was considerably thicker in the guinea-pig than in the rats. Lens blockage by the dilated iris was lowest in the guinea-pig. Maximum tolerable dose for avoidance of UVR-B-induced cataract in the pigmented guinea-pig was 69.0 kJ/m(2), over 10-fold higher than the threshold 5 kJ/m(2) obtained by Pitts et al. in the pigmented rabbit. Maximum tolerable dose is an appropriate method for estimation of toxicity for UVR-B-induced cataract in the guinea-pig. The pigmented guinea-pig is significantly less sensitive to UVR-B exposure than the pigmented rabbit and pigmented rat. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  17. The consequences of a reduction in the administratively applied maximum annual dose equivalent level for an individual in a group of occupationally exposed workers

    International Nuclear Information System (INIS)

    Harrison, N.T.

    1980-02-01

    An analysis is described for predicting the consequences of a reduction in the administratively applied maximum dose equivalent level to individuals in a group of workers occupationally exposed to ionising radiations, for the situation in which no changes are made to the working environment. This limitation of the maximum individual dose equivalent is accommodated by allowing the number of individuals in the working group to increase. The derivation of the analysis is given, together with worked examples, which highlight the important assumptions that have been made and the conclusions that can be drawn. The results are obtained in the form of the capacity of the particular working environment to accommodate the limitation of the maximum individual dose equivalent, the increase in the number of workers required to carry out the productive work and any consequent increase in the occupational collective dose equivalent. (author)

  18. Neo-adjuvant radiotherapy focused by Cyberknife in the breast cancer: phase one test of Cyberneo dose escalation; Radiotherapie neoadjuvante focalisee par Cyberknife dans le cancer du sein: essai de phase I d'escalade de dose Cyberneo

    Energy Technology Data Exchange (ETDEWEB)

    Bondiau, P.Y.; Courdi, A.; Lallemand, M.; Peyrote, I.; Chapellier, C.; Ferrero, J.M

    2007-11-15

    The principal evaluation criterion is the maximum tolerated dose ( limiting dose if toxicity {>=} grade 3, recommended if toxicity {<=} 2). The deep cutaneous toxicity is evaluated by two independent observers by colorimetry, macro photographs and video capillaroscopy. The secondary evaluation criteria are the easiness of surgery, the therapeutical effect evaluated on the surgery piece (Sataloff classification) and the measurement of the quality of life. (N.C.)

  19. Radiation tolerance of the spinal cord previously-damaged by tumor operation: long term neurological improvement and time-dose-volume relationships after irradiation of intraspinal gliomas

    International Nuclear Information System (INIS)

    Kopelson, G.

    1982-01-01

    Of 26 patients with intramedullary spinal cord gliomas (9 astrocytomas, 5 glioblastomas, 12 ependymomas) seen at the Massachusetts General Hospital from 1962-1980, 24 were irradiated (21 initially and 3 after post-surgical recurrence). Those 19 patients who survived at least 1 year after completion of irradiation were evaluated for post-irradiation neurological changes.No patient developed radiation myelopathy. Return to a permanently and completely normal neurological status occured for 33/51 (65%) of pre-irradiation neurological deficits. The major cause of post-irradiation neurological deterioration was tumor recurrence. Although 18/19 patients had their thoracic or lumbar spinal cords irradiated, each with field sizes greater than 10 cm, spinal cord doses approaching, equalling, or occasionally exceeding various definitions of spinal cord tolerance were tolerated well without evidence of radiation myelopathy. Spinal cords of patients with intramedullary gliomas, often with major neurological deficits prior to irradiation, may be treated safely to doses approaching or equalling spinal cord tolerance levels. These doses are expected to locally control most ependymomas and astrocytomas without an increased radiation myelopathy. Caution should be observed if doses higher than this are contemplated in an attempt to cure glioblastoma, because the 5% tolerance level of the damaged spinal remains to be defined

  20. Safety, efficacy and pharmacokinetics of neratinib (HKI-272) in Japanese patients with advanced solid tumors: a Phase 1 dose-escalation study.

    Science.gov (United States)

    Ito, Yoshinori; Suenaga, Mitsukuni; Hatake, Kiyohiko; Takahashi, Shunji; Yokoyama, Masahiro; Onozawa, Yusuke; Yamazaki, Kentaro; Hironaka, Shuichi; Hashigami, Kiyoshi; Hasegawa, Hirotaka; Takenaka, Nobuko; Boku, Narikazu

    2012-04-01

    Neratinib (HKI-272), a potent, irreversible, small-molecule, orally administered, pan-ErbB inhibitor that blocks signal transduction via inhibition of three epidermal growth factor receptors [ErbB1, ErbB2 (Her2) and ErbB4], is being developed for the treatment of solid tumors, including breast cancer. This Phase 1 dose-escalation study assessed the safety, tolerability, maximum-tolerated dose, antitumor activity and pharmacokinetics of neratinib in Japanese patients with advanced solid tumors. Patients received neratinib 80, 160, 240 or 320 mg orally; each patient enrolled in only one dose cohort. Patients received a single dose in week 1, followed by daily continuous doses. Blood samples collected were on days 1 and 21 for pharmacokinetic analyses. Twenty-one patients were enrolled (3 breast cancer; 17 colorectal cancer; 1 gastric cancer). Neratinib-related adverse events (all grades) included diarrhea (20 patients), fatigue (14 patients), nausea and abdominal pain (9 patients each) and anorexia (8 patients). Grade ≥3 neratinib-related adverse events in two or more patients were diarrhea and anorexia (two patients each). Dose-limiting toxicities were diarrhea and anorexia (two patients, 320 mg dose). The maximum-tolerated dose and recommended dose was neratinib 240 mg once daily. Of 21 evaluable patients, 2 with breast cancer had partial response, 3 had stable disease ≥24 weeks, 7 had stable disease ≥16 weeks and 9 had progressive disease. Pharmacokinetic analyses indicated that neratinib exposures increased with dose. The safety, efficacy and pharmacokinetic profiles of neratinib are consistent with those reported for non-Japanese patients and warrant further investigation of neratinib in Japanese patients with solid tumors.

  1. Tolerance of Glyphosate-Resistant Maize to Glyphosate Plus MCPA Amine Is Influenced by Dose and Timing

    Directory of Open Access Journals (Sweden)

    Nader Soltani

    2015-01-01

    Full Text Available There is little information on tolerance of glyphosate-resistant maize to glyphosate plus MCPA amine as influenced by dose and timing under Ontario environmental conditions. A total of seven field trials were conducted at various locations in Ontario, Canada, in 2011–2013 to evaluate tolerance of field maize to tank mixes of glyphosate (900 g a.e./ha plus MCPA amine (79, 158, 315, 630, 1260, 2520, or 5040 g a.e./ha at either the 4- or 8-leaf stage. The predicted dose of MCPA amine that caused 5, 10, and 20% injury was 339, 751, and 1914 g a.e./ha when applied to 4-leaf maize but only 64, 140, and 344 g a.e./ha when applied to 8-leaf maize, respectively. The predicted dose of MCPA amine that caused 5, 10, and 20% reduction in shoot dry weight of maize was 488, 844, and 1971 g a.e./ha when applied to 4-leaf maize and only 14, 136, and 616 g a.e./ha when applied to 8-leaf maize, respectively. The predicted dose of MCPA amine that caused 5, 10, and 20% yield reduction was 2557, 4247, and >5040 g a.e./ha when applied to 4-leaf maize and 184, 441, and 1245 g a.e./ha when applied to 8-leaf maize, respectively. Based on these results, glyphosate plus MCPA amine applied at the manufacturer’s recommended dose of 630 g a.e./ha applied to 4-leaf maize has potential to cause injury but the injury is transient with no significant reduction in yield. However, when glyphosate plus MCPA amine is applied to 8-leaf maize it has the potential to cause significant injury and yield loss in maize.

  2. Dose prescription in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gupta, N.M.S.; Gahbauer, R.A.; Blue, T.E.; Wambersie, A.

    1994-01-01

    The purpose of this paper is to address some aspects of the many considerations that need to go into a dose prescription in boron neutron capture therapy (BNCT) for brain tumors; and to describe some methods to incorporate knowledge from animal studies and other experiments into the process of dose prescription. Previously, an algorithm to estimate the normal tissue tolerance to mixed high and low linear energy transfer radiations in BNCT was proposed. The authors have developed mathematical formulations and computational methods to represent this algorithm. Generalized models to fit the central axis dose rate components for an epithermal neutron field were also developed. These formulations and beam fitting models were programmed into spreadsheets to simulate two treatment techniques which are expected to be used in BNCT: a two-field bilateral scheme and a single-field treatment scheme. Parameters in these spreadsheets can be varied to represent the fractionation scheme used, the 10 B microdistribution in normal tissue, and the ratio of 10 B in tumor to normal tissue. Most of these factors have to be determined for a given neutron field and 10 B compound combination from large animal studies. The spreadsheets have been programmed to integrate all of the treatment-related information and calculate the location along the central axis where the normal tissue tolerance is exceeded first. This information is then used to compute the maximum treatment time allowable and the maximum tumor dose that may be delivered for a given BNCT treatment. The effect of different treatment variables on the treatment time and tumor dose has been shown to be very significant. It has also been shown that the location of D max shifts significantly, depending on some of the treatment variables-mainly the fractionation scheme used. These results further emphasize the fact that dose prescription in BNCT is very complicated and nonintuitive. 11 refs., 6 figs., 3 tabs

  3. Characterization and optimization of the RA-3 experimental dosimetry for normal sheep lung radio-tolerance study

    International Nuclear Information System (INIS)

    Soto, M.S.; Gonzalez, S.J.; Thorp, Silvia I.; Pozzi, Emiliano; Gadan, M.; Miller, Marcelo; Farias, R.

    2009-01-01

    In the spirit of the novel technique proposed by the University of Pavia group (Italy) to irradiate an isolated organ using BNCT, the Comision Nacional de Energia Atomica (CNEA) in collaboration with the Fundacion Favaloro has initiated a project that aims to investigate the feasibility of BNCT for ex-situ treatment of diffuse metastatic disease in the lungs. The present work was carried out in the framework of the undergoing experimental study of the radio tolerance of normal sheep lung. With the purpose of characterizing and optimizing the resulting experimental dosimetry in normal lung subjected to neutron irradiation in the BNCT facility of the RA-3 reactor (CNEA), we have performed a series of experiments to find the optimum configuration of the container-lung system deriving a dose distribution preferentially uniform throughout the organ. Once the optimal set-up was established, we measured the total gamma dose rate and estimated the irradiation time compatible with the maximum tolerable dose of normal lung resulting from previous studies in rats. This estimation was performed using RBE, CBE and tolerance dose values derived from radiobiological studies with BNCT. In parallel with the experimental characterization, we built two different computational models of the container-lung system to perform Monte Carlo simulation with MCNP and Treatment Planning System NCTPlan. (author)

  4. A Detailed Dosimetric Analysis of Spinal Cord Tolerance in High-Dose Spine Radiosurgery.

    Science.gov (United States)

    Katsoulakis, Evangelia; Jackson, Andrew; Cox, Brett; Lovelock, Michael; Yamada, Yoshiya

    2017-11-01

    Dose-volume tolerance of the spinal cord (SC) in spinal stereotactic radiosurgery (SRS) is difficult to define because radiation myelitis rates are low, and published reports document cases of myelopathy but do not account for the total number of patients treated at given dose-volume combinations who do not have myelitis. This study reports SC toxicity from single-fraction spinal SRS and presents a comprehensive atlas of the incidence of adverse events to examine dose-volume predictors. A prospective database of all patients undergoing single-fraction spinal SRS at our institution between 2004 and 2011 was reviewed. SC toxicity was defined by clinical myelitis with accompanying magnetic resonance imaging (MRI) signal changes that were not attributable to tumor progression. Dose-volume histogram (DVH) atlases were created for these endpoints. Rates of adverse events with 95% confidence limits and probabilities that rates of adverse events were 13.33 Gy, and minimum doses to the hottest 0.1, 0.2, 0.5, and 1 cc were >10.66, 10.9, and 8 Gy, respectively; however, both myelitis cases occurred below the 34th percentile for Dmax and there were 194 DVHs in total with Dmax >13.33 Gy. A median SC Dmax of 13.85 Gy is safe and supports that a Dmax limit of 14 Gy carries a low <1% rate of myelopathy. No dose-volume thresholds or relationships between SC dose and myelitis were apparent. This is the largest study examining dosimetric data and radiation-induced myelitis in de novo spine SRS. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Inefficacy of high-dose transdermal fentanyl in a patient with neuropathic pain, a case report.

    NARCIS (Netherlands)

    Bleeker, C.P.; Bremer, R.; Dongelmans, D.A.; Dongen, R.T.M. van; Crul, B.J.P.

    2001-01-01

    Pain partially responsive to opioids can lead to rapid escalating dosages due to tolerance development. In this report the case of a 58-year-old female with neuropathic pain using increasing transdermal (TTS) fentanyl dosages to a maximum dose of 3400 microg/h resulting in fentanyl plasma levels of

  6. The individual tolerance concept is not the sole explanation for the probit dose-effect model

    Energy Technology Data Exchange (ETDEWEB)

    Newman, M.C.; McCloskey, J.T.

    2000-02-01

    Predominant methods for analyzing dose- or concentration-effect data (i.e., probit analysis) are based on the concept of individual tolerance or individual effective dose (IED, the smallest characteristic dose needed to kill an individual). An alternative explanation (stochasticity hypothesis) is that individuals do not have unique tolerances: death results from stochastic processes occurring similarly in all individuals. These opposing hypotheses were tested with two types of experiments. First, time to stupefaction (TTS) was measured for zebra fish (Brachydanio rerio) exposed to benzocaine. The same 40 fish were exposed during five trials to test if the same order for TTS was maintained among trials. The IED hypothesis was supported with a minor stochastic component being present. Second, eastern mosquitofish (Gambusia holbrooki) were exposed to sublethal or lethal NaCl concentrations until a large portion of the lethally exposed fish died. After sufficient time for recovery, fish sublethally exposed and fish surviving lethal exposure were exposed simultaneously to lethal NaCl concentrations. No statistically significant effect was found of previous exposure on survival time but a large stochastic component to the survival dynamics was obvious. Repetition of this second type of test with pentachlorophenol also provided no support for the IED hypothesis. The authors conclude that neither hypothesis alone was the sole or dominant explanation for the lognormal (probit) model. Determination of the correct explanation (IED or stochastic) or the relative contributions of each is crucial to predicting consequences to populations after repeated or chronic exposures to any particular toxicant.

  7. Phase I dose escalation, pharmacokinetic and pharmacodynamic study of naptumomab estafenatox alone in patients with advanced cancer and with docetaxel in patients with advanced non-small-cell lung cancer

    DEFF Research Database (Denmark)

    Borghaei, Hossein; Alpaugh, Katherine; Hedlund, Gunnar

    2009-01-01

    recognizing the tumor-associated antigen 5T4. PATIENTS AND METHODS: Patients with non-small-cell lung cancer (NSCLC), pancreatic cancer (PC), and renal cell cancer (RCC) received 5 daily boluses of ABR-217620 (3-month cycles) in escalating doses to determine the maximum-tolerated dose (MTD; ABR-217620 dose...

  8. MAK and BAT values list 2017. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2017. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-08-01

    The MAK and BAT values list 2017 includes the maximum permissible concentrations at the place of work and biological tolerance values for working materials. The following working materials are covered: carcinogenic working materials, sensitizing materials and aerosols. The report discusses the restriction of exposure peaks, skin resorption, MAK (maximum working place concentration) values during pregnancy, germ cell mutagens and specific working materials. Importance and application of BAT (biological working material tolerance) values, list of materials, carcinogens, biological guide values and reference values are also included.

  9. Phase 1 Dose Escalation Study of Accelerated Radiation Therapy With Concurrent Chemotherapy for Locally Advanced Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kelsey, Chris R., E-mail: christopher.kelsey@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Das, Shiva [Department of Radiation Oncology, University of North Carolina School of Medicine, Chapel Hill, North Carolina (United States); Gu, Lin [Department of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina (United States); Dunphy, Frank R.; Ready, Neal E. [Division of Medical Oncology, Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States); Marks, Lawrence B. [Department of Radiation Oncology, University of North Carolina School of Medicine, Chapel Hill, North Carolina (United States)

    2015-12-01

    Purpose: To determine the maximum tolerated dose of radiation therapy (RT) given in an accelerated fashion with concurrent chemotherapy using intensity modulated RT. Methods and Materials: Patients with locally advanced lung cancer (non-small cell and small cell) with good performance status and minimal weight loss received concurrent cisplatin and etoposide with RT. Intensity modulated RT with daily image guidance was used to facilitate esophageal avoidance and delivered using 6 fractions per week (twice daily on Fridays with a 6-hour interval). The dose was escalated from 58 Gy to a planned maximum dose of 74 Gy in 4 Gy increments in a standard 3 + 3 trial design. Dose-limiting toxicity (DLT) was defined as acute grade 3-5 nonhematologic toxicity attributed to RT. Results: A total of 24 patients were enrolled, filling all dose cohorts, all completing RT and chemotherapy as prescribed. Dose-limiting toxicity occurred in 1 patient at 58 Gy (grade 3 esophagitis) and 1 patient at 70 Gy (grade 3 esophageal fistula). Both patients with DLTs had large tumors (12 cm and 10 cm, respectively) adjacent to the esophagus. Three additional patients were enrolled at both dose cohorts without further DLT. In the final 74-Gy cohort, no DLTs were observed (0 of 6). Conclusions: Dose escalation and acceleration to 74 Gy with intensity modulated RT and concurrent chemotherapy was tolerable, with a low rate of grade ≥3 acute esophageal reactions.

  10. Short-term digestive tolerance of different doses of NUTRIOSE FB, a food dextrin, in adult men.

    Science.gov (United States)

    van den Heuvel, E G H M; Wils, D; Pasman, W J; Bakker, M; Saniez, M-H; Kardinaal, A F M

    2004-07-01

    To determine the tolerance of increasing dosages of an incompletely hydrolysed and/or incompletely absorbed food dextrin coming from wheat starch, NUTRIOSE FB, at daily levels of 10 and 15 g up to 60 and 80 g, respectively. A randomized, double-blind, multiple dose, placebo-controlled, combined crossover and parallel trial. The metabolic ward of TNO Nutrition and Food Research. A total of 20 healthy men (age 31.7 +/- 9.1 y; BMI 24.5 +/- 2.9 kg/m2). One group of 10 subjects consumed on top of their diet 10, 30 and 60 g of NUTRIOSE FB or maltodextrin (placebo) daily. The other group of 10 subjects consumed 15, 45 and 80 g daily. Each dose was consumed for 7 days. Compared with placebo, flatulence occurred more frequently over the last 6 days on 30, 60 or 80 g/day of NUTRIOSE FB (P FB, the frequency of flatulence was even higher (P FB, the frequency of defecation decreased (P FB (P FB resulted in diarrhoea. Compared to baseline levels, breath H2 excretion, which was only measured after a week with 10 and 15 g of NUTRIOSE FB daily, increased (P FB is a fermentable carbohydrate and is well tolerated up to a dose of 45 g daily. Higher daily dosages (60 and 80 g) may result in flatulence, but does not result in diarrhoea. TNO Nutrition and Food Research was assigned by Roquette Frères to perform the study.

  11. A Phase 1, Single-center, Double-blind, Placebo-controlled Study in Healthy Subjects to Assess the Safety, Tolerability, Clinical Effects, and Pharmacokinetics-Pharmacodynamics of Intravenous Cyclopropyl-methoxycarbonylmetomidate (ABP-700) after a Single Ascending Bolus Dose.

    Science.gov (United States)

    Struys, Michel M R F; Valk, Beatrijs I; Eleveld, Douglas J; Absalom, Anthony R; Meyer, Peter; Meier, Sascha; den Daas, Izaak; Chou, Thomas; van Amsterdam, Kai; Campagna, Jason A; Sweeney, Steven P

    2017-07-01

    Cyclopropyl-methoxycarbonylmetomidate (ABP-700) is a new "soft" etomidate analog. The primary objectives of this first-in-human study were to describe the safety and efficacy of ABP-700 and to determine its maximum tolerated dose. Secondary objectives were to characterize the pharmacokinetics of ABP-700 and its primary metabolite (cyclopropyl-methoxycarbonyl acid), to assess the clinical effects of ABP-700, and to investigate the dose-response and pharmacokinetic/pharmacodynamic relationships. Sixty subjects were divided into 10 cohorts and received an increasing, single bolus of either ABP-700 or placebo. Safety was assessed by clinical laboratory evaluations, infusion-site reactions, continuous monitoring of vital signs, physical examination, adverse event monitoring, and adrenocorticotropic hormone stimulation testing. Clinical effects were assessed with modified observer's assessment of alertness/sedation and Bispectral Index monitoring. Pharmacokinetic parameters were calculated. Stopping criteria were met at 1.00 mg/kg dose. No serious adverse events were reported. Adverse events were dose-dependent and comprised involuntary muscle movement, tachycardia, and ventilatory effects. Adrenocorticotropic hormone stimulation evoked a physiologic cortisol response in all subjects, no different from placebo. Pharmacokinetics were dose-proportional. A three-compartment pharmacokinetic model described the data well. A rapid onset of anesthesia/sedation after bolus administration and also a rapid recovery were observed. A quantitative concentration-effect relationship was described for the modified observer's assessment of alertness/sedation and Bispectral Index. This first-in-human study of ABP-700 shows that ABP-700 was safe and well tolerated after single-bolus injections up to 1.00 mg/kg. Bolus doses of 0.25 and 0.35 mg/kg were found to provide the most beneficial clinical effect versus side-effect profile.

  12. Maximum likelihood estimation of dose-response parameters for therapeutic operating characteristic (TOC) analysis of carcinoma of the nasopharynx

    International Nuclear Information System (INIS)

    Metz, C.E.; Tokars, R.P.; Kronman, H.B.; Griem, M.L.

    1982-01-01

    A Therapeutic Operating Characteristic (TOC) curve for radiation therapy plots, for all possible treatment doses, the probability of tumor ablation as a function of the probability of radiation-induced complication. Application of this analysis to actual therapeutic situation requires that dose-response curves for ablation and for complication be estimated from clinical data. We describe an approach in which ''maximum likelihood estimates'' of these dose-response curves are made, and we apply this approach to data collected on responses to radiotherapy for carcinoma of the nasopharynx. TOC curves constructed from the estimated dose-response curves are subject to moderately large uncertainties because of the limitations of available data.These TOC curves suggest, however, that treatment doses greater than 1800 rem may substantially increase the probability of tumor ablation with little increase in the risk of radiation-induced cervical myelopathy, especially for T1 and T2 tumors

  13. Multiple dose study of the combined radiosensitizers Ro 03-8799 (pimonidazole) and SR 2508 (etanidazole)

    International Nuclear Information System (INIS)

    Bleehen, N.M.; Newman, H.F.; Maughan, T.S.; Workman, P.

    1989-01-01

    The hypoxic cell radiosensitizers Ro 03-8799 and SR 2508 have different clinical toxicities. The former produces an acute but transient central nervous system syndrome, whereas the latter produces cumulative peripheral neuropathy. Following single dose studies, an escalating multiple dose schedule using both drugs in combination showed no unexpected adverse reactions at lower doses. This study identifies the clinical tolerance and pharmacokinetics when doses in the region of the maximal tolerated dose are given to 26 patients receiving infusions of 0.75 g/m2 Ro 03-8799 and 2 g/m2 SR 2508 three times per week. At 15 doses, 3/4 patients experienced WHO grade 2 peripheral neuropathy, whereas at 12 doses 1/9 developed grade 2 and 6/9 developed grade 1 neuropathies. This represents a lower dose of SR 2508 than can be given alone suggesting that some interaction between the two drugs does exist in terms of chronic peripheral neurotoxicity. Pharmacokinetic studies show no adverse interactions between the two drugs and minimal inter-patient variation. From bivariate analysis, cumulative AUC for Ro 03-8799 has the most significant correlation with the development of peripheral neuropathy. Tumor drug concentrations normalized to the administered dose show mean values of 34 micrograms/g Ro 03-8799 and 76 micrograms/g SR 2508 30 minutes after infusion. These could be expected to produce a single dose sensitizer enhancement ratio of 1.5. The combination of the two sensitizers at the maximum tolerable dose may be expected to give an increased therapeutic efficacy over either drug alone

  14. Safety, tolerability and pharmacokinetics of doravirine, a novel HIV non-nucleoside reverse transcriptase inhibitor, after single and multiple doses in healthy subjects.

    Science.gov (United States)

    Anderson, Matt S; Gilmartin, Jocelyn; Cilissen, Caroline; De Lepeleire, Inge; Van Bortel, Luc; Dockendorf, Marissa F; Tetteh, Ernestina; Ancona, June K; Liu, Rachael; Guo, Ying; Wagner, John A; Butterton, Joan R

    2015-01-01

    Doravirine is a novel non-nucleoside inhibitor of HIV-1 reverse transcriptase with potent activity against wild-type virus (95% inhibitory concentration 19 nM, 50% human serum). Doravirine has low potential to cause drug-drug interactions since it is primarily eliminated by oxidative metabolism and does not inhibit or significantly induce drug-metabolizing enzymes. The pharmacokinetics and safety of doravirine were investigated in two double-blind, dose-escalation studies in healthy males. Thirty-two subjects received single doses of doravirine (6-1,200 mg) or matching placebo tablets; 40 subjects received doravirine (30-750 mg) or matching placebo tablets once daily for 10 days. In addition, the effect of doravirine (120 mg for 14 days) on single-dose pharmacokinetics of the CYP3A substrate midazolam was evaluated (10 subjects). The maximum plasma concentration (Cmax) of doravirine was achieved within 1-5 h with an apparent terminal half-life of 12-21 h. Consistent with single-dose pharmacokinetics, steady state was achieved after approximately 7 days of once daily administration, with accumulation ratios (day 10/day 1) of 1.1-1.5 in the area under the plasma concentration-time curve during the dosing interval (AUC0-24 h), Cmax and trough plasma concentration (C24 h). All dose levels produced C24 h>19 nM. Administration of 50 mg doravirine with a high-fat meal was associated with slight elevations in AUC time zero to infinity (AUC0-∞) and C24 h with no change in Cmax. Midazolam AUC0-∞ was slightly reduced by coadministration of doravirine (geometric mean ratio 0.82, 90% CI 0.70, 0.97). There was no apparent relationship between adverse event frequency or intensity and doravirine dose. No rash or significant central nervous system events other than headache were reported. Doravirine is generally well tolerated in single doses up to 1,200 mg and multiple doses up to 750 mg once daily for up to 10 days, with a pharmacokinetic profile supportive of once

  15. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  16. Volume correction factor in time dose relationships in brachytherapy

    International Nuclear Information System (INIS)

    Supe, S.J.; Sasane, J.B.

    1987-01-01

    Paterson's clinical data about the maximum tolerance doses for various volumes of interstitial implants with Ra-226 delivered in seven days was made use of in deriving volume correction factors for TDF and CRE concepts respectively for brachytherapy. The derived volume correction factors for TDF and for CRE differ fromthe one assumed for CRE by Kirk et al. and implied for TDF by Goitein. A normalising volume of 70 cc has been suggested for both CRE and TDF concepts for brachytherapy. A table showing the volume corrected TDF is presented for various volumes and dose rates for continuous irradiation. The use of this table is illustrated with examples. (orig.) [de

  17. Optimizing bevacizumab dosing in glioblastoma: less is more.

    Science.gov (United States)

    Ajlan, Abdulrazag; Thomas, Piia; Albakr, Abdulrahman; Nagpal, Seema; Recht, Lawrence

    2017-10-01

    Compared to traditional chemotherapies, where dose limiting toxicities represent the maximum possible dose, monoclonal antibody therapies are used at doses well below maximum tolerated dose. However, there has been little effort to ascertain whether there is a submaximal dose at which the efficacy/complication ratio is maximized. Thus, despite the general practice of using Bevacizumab (BEV) at dosages of 10 mg/kg every other week for glioma patients, there has not been much prior work examining whether the relatively high complication rates reported with this agent can be decreased by lowering the dose without impairing efficacy. We assessed charts from 80 patients who received BEV for glioblastoma to survey the incidence of complications relative to BEV dose. All patients were treated with standard upfront chemoradiation. The toxicity was graded based on the NCI CTCAE, version 4.03. The rate of BEV serious related adverse events was 12.5% (n = 10/80). There were no serious adverse events (≥grade 3) when the administered dose was (<3 mg/kg/week), compared to a 21% incidence in those who received higher doses (≥3 mg/kg/week) (P < 0.01). Importantly, the three patient deaths attributable to BEV administration occurred in patients receiving higher doses. Patients who received lower doses also had a better survival rate, although this did not reach statistical significance [median OS 39 for low dose group vs. 17.3 for high dose group (P = 0.07)]. Lower rates of serious BEV related toxicities are noted when lower dosages are used without diminishing positive clinical impact. Further work aimed at optimizing BEV dosage is justified.

  18. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  19. An iterative method applied to optimize the design of PIN photodiodes for enhanced radiation tolerance and maximum light response

    International Nuclear Information System (INIS)

    Cedola, A.P.; Cappelletti, M.A.; Casas, G.; Peltzer y Blanca, E.L.

    2011-01-01

    An iterative method based on numerical simulations was developed to enhance the proton radiation tolerance and the responsivity of Si PIN photodiodes. The method allows to calculate the optimal values of the intrinsic layer thickness and the incident light wavelength, in function of the light intensity and the maximum proton fluence to be supported by the device. These results minimize the effects of radiation on the total reverse current of the photodiode and maximize its response to light. The implementation of the method is useful in the design of devices whose operation point should not suffer variations due to radiation.

  20. Tolerance of rat spinal cord to continuous interstitial irradiation

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Ruifrok, Arnout C.C.; Schalkwijk, Lia J.M.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1998-01-01

    Purpose: To study the kinetics of repair in rat spinal cord during continuous interstitial irradiation at different dose rates and to investigate the impact of a rapid dose fall off over the spinal cord thickness. Material and Methods: Two parallel catheters were inserted on each side of the vertebral bodies from the level of T 10 to L 4 . These catheters were afterloaded with two 192 Ir- wires of 4 cm length each (activity 1 - 10 mCi/cm) or connected to the HDR- microSelectron. Experiments have been carried out to obtain complete dose response curves at 7 different dose rates: 0.53, 0.90, 1.64, 2.56, 4.4, 9.9 and 120 Gy/h. Paralysis of the hindlegs after 5 - 6 months and histopathological examination of the spinal cord of each animal were used as experimental endpoints. Results: The distribution of the histological damage was a good reflection of the rapid dose fall - off over the spinal cord, with white matter necrosis or demyelination predominantly seen in the dorsal tracts of the spinal cord or dorsal roots. With each reduction of the dose rate, spinal cord tolerance was significantly increased, with a maximum dose rate factor of 4.3 if the dose rate was reduced from 120 Gy/h to 0.53 Gy/h (ED 50 of 17.3 Gy and 75.0 Gy, respectively). Estimates of the repair parameters using different types of analysis are presented. For the direct analysis the best fit of the data was obtained if a biexponential function for repair was used. For the 100% dose prescribed at the ventral side of the spinal cord the (α(β)) ratio is 1.8 Gy (0.8 - 2.8) and two components of repair are observed: a slow component of repair of 2.44 h (1.18 - ∞) and a fast component of 0.15 h (0.02 - ∞). The proportion of the damage repaired with the slow component is 0.59 (0.18 - 1). For the maximum of 150% of the prescribed dose at the dorsal side of the spinal cord the (α(β)) ratio is 2.7 Gy (1.5 - 4.4); the two components for the kinetics of repair remain the same. Conclusions: Spinal cord

  1. Normal tissue tolerance to external beam radiation therapy: Cardiac structures; Dose de tolerance des tissus sains: le coeur

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France); Giraud, P. [Universite Rene-Descartes Paris 5, 75 - Paris (France); Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, 75 - Paris (France); Belkacemi, Y. [Faculte de medecine de Creteil, universite Paris 12, 94 - Creteil (France); Service d' oncologie-radiotherapie, CHU Henri-Mondor, 94 - Creteil (France)

    2010-07-15

    Radiation thoracic tumors may be associated with cardiac toxicity because of the central position of the heart in the thorax. The present review aims to describe the cardiotoxicity during radiotherapy of different tumor sites most associated with this complication and the risk factors of cardiotoxicity during radiation therapy. Medline literature searches were performed using the following cardiac - heart - radiotherapy - toxicity - cardiotoxicity - breast cancer - lymphoma. Cardiac toxicity after breast cancer and mediastinal lymphoma is the most reported radiation-induced complication. The most frequent clinical complications are pericarditis, congestive heart failure, and heart infarction. These events are mostly asymptomatic. Thus clinicians have to give particular attention to these complications. Anthracycline treatment is a major risk factor for additional cardiotoxicity during radiotherapy with a synergistic effect. Correction of cardiovascular risk is an important point of the prevention of heart complications. Total dose delivered to the planned target volume (PTV), the dose per fraction and the irradiated volume were correlated to the risk of cardiotoxicity. Volume of heart receiving 35 Gy must be inferior to 30% and dose per fraction should not exceed 2 Gy when dose of prescription exceeds 30 Gy. Maximum heart distance (maximal thickness of heart irradiated) must be less than 1 cm during irradiation of breast cancer. Modern irradiation techniques seem to be associated with a limited risk of heart complication. The use of anthracycline, other cardio-toxic chemotherapies and targeted therapies should incite for great caution by performing a careful treatment planning and optimisation. (authors)

  2. MAK and BAT values list 2015. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2015. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-11-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2015 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  3. MAK and BAT values list 2014. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2014. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-11-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2014 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  4. MAK and BAT values list 2013. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2013. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2013 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  5. Effect of a simple dose-escalation schedule on tramadol tolerability : assessment in the clinical setting.

    Science.gov (United States)

    Tagarro, I; Herrera, J; Barutell, C; Díez, M C; Marín, M; Samper, D; Busquet, C; Rodríguez, M J

    2005-01-01

    To assess the effect of a very simple dose-escalation schedule on tramadol tolerability in clinical practice. This schedule consists of starting treatment with sustained-release tramadol 50mg twice daily, and escalating the dose around 7 days later to 100mg twice daily. Data from 1925 outpatients with non-malignant chronic pain were collected in this multicentre, prospective, comparative, non-randomised, open, observational study. A total of 1071 patients (55.6%) were included in the dose-escalation group (50mg group) and 854 patients (44.4%) in the control group (sustained-release tramadol 100mg twice daily; 100mg group). The proportion of patients who interrupted tramadol treatment due to the occurrence of adverse reactions was significantly lower in the 50mg group (5.6%) than in the 100mg group (12.6%) [p = 0.001]. In line with this, the proportion of patients who experienced at least one adverse reaction was significantly lower in the 50mg group (18.4%) than in the 100mg group (30.4%) [p = 0.001] and, interestingly, the two most frequently reported adverse reactions, nausea and dizziness, were found with a significantly lower frequency in the 50mg group (p < 0.001). Multivariate analysis showed that the risk of safety-related treatment cessations was 2.3 times higher in the 100mg group than in the 50mg group, and 2.2 times higher in females than in males. The two treatments were equally effective in reducing pain intensity (p = 0.121), measured as a reduction in pain score obtained by means of a visual analogue scale. The instauration of tramadol treatment, starting with sustained-release 50mg capsules twice daily and escalating the dose some days later to 100mg twice daily, was shown to be an effective and easy way to improve tramadol tolerability in clinical practice, whilst maintaining its analgesic efficacy.

  6. Normal tissue tolerance to external beam radiation therapy: Larynx and pharynx; Dose de tolerance a l'irradiation des tissus sains: larynx et pharynx

    Energy Technology Data Exchange (ETDEWEB)

    Debelleix, C. [Service de radiotherapie, centre hospitalier Dax-Cote d' Argent, 40 - Dax (France); Service de radiotherapie, hopital Saint-Andre, CHU de Bordeaux, 33 - Bordeaux (France); Pointreau, Y.; Calais, G. [Service de radiotherapie, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau, CHU de Tours, 37 - Tours (France); Universite Francois-Rabelais, 37 - Tours (France); Pointreau, Y. [CNRS, UMR 6239 Genetique, immunotherapie, chimie et cancer, 37 - Tours (France); Laboratoire de pharmacologie-toxicologie, CHRU de Tours, 37 - Tours (France); Lafond, C.; Denis, F. [Centre Jean-Bernard, clinique Victor-Hugo, 72 - Le Mans (France); Bourhis, J.H. [Institut Gustave-Roussy, 94 - Villejuif (France)

    2010-07-15

    For head and neck cancers, the radiation dose usually needed to sterilize a macroscopic tumour is at least 70 Gy in conventional fractionation. In the larynx, this dose level enables optimal tumour control while exposing the patient to a limited risk of severe complications. For oropharynx and nasopharynx tumors, it is sometimes possible to limit the dose received by the larynx according to the extent of the primary lesion. Thus, if the tumour constraints permit, the maximum dose to the larynx must be less than 63 to 66 Gy. To reduce the risk of laryngeal edema, it is recommended if possible to limit the mean non-involved larynx dose to 40 to 45 Gy. In the pharynx, literature's data suggested to minimize the volume of the pharyngeal constrictor muscles receiving a dose greater than or equal to 60 Gy. Limiting the volume receiving a dose greater than or equal to 50 Gy reduces the risk of dysphagia. These dose constraints should be tailored to each patient taking into account the extent of the initial primary lesion, the possible addition of chemotherapy or a modified fractionation radiotherapy. (authors)

  7. A phase I study of amrubicin and fixed dose of irinotecan (CPT-11) in relapsed small cell lung cancer: Japan multinational trial organization LC0303.

    Science.gov (United States)

    Kawahara, Masaaki; Kubo, Akihito; Komuta, Kiyoshi; Fujita, Yuka; Sasaki, Yoshiaki; Fukushima, Masanori; Daimon, Takashi; Furuse, Kiyoyuki; Mishima, Michiaki; Mio, Tadashi

    2012-12-01

    To determine the maximum tolerated dose of amrubicin (AMR) with a fixed dose of irinotecan (CPT-11). Patients having pathologically proven small cell lung cancer (SCLC) relapsed after one or two chemotherapies, and Eastern Cooperative Oncology Group performance status of 0 to 2 were eligible for the study. CPT-11 was delivered as 50 mg/m2 on days 1 and 8, every 21 days. AMR was delivered on day 1. Doses of AMR were level 1: 80 mg/m2, level 2: 90 mg/m2, and level 3: 100 mg/m2. Dose elevation was determined using the modified continuous reassessment method. Tolerability was assessed after the first cycle. Another two cycles were conducted when disease progression or unacceptable toxicities were not observed. Eighteen patients (mean age: 66.3 years) were enrolled. A total of 40 courses were conducted. Grade 3/4 toxicities of the first cycle were leukocytopenia: 11 (61%, grade 3/4: 8/3); neutropenia: 15 (83%, grade 3/4: 6/9); and thrombocytopenia: three (17%, grade 3/4: 2/1). Other grade 3 toxicities observed were febrile neutropenia, one; infection, three; diarrhea, one; and dyspnea, one. Dose-limiting toxicity was observed in two of six patients at level 2 (neutropenia and febrile neutropenia) and in one of six at level 3 (thrombocytopenia and infection). The maximum tolerated dose was level 3, and so, the recommended dose for phase II trials was judged to be 90 mg/m2. Objective response was obtained in four of eight patients who were able to evaluate responses. Median survival time was 13 months, with 68% at 1-year survival rate. This combination was well tolerated and showed encouraging activities in SCLC. Randomized phase II trials are being planned in chemonaive SCLC.

  8. Phase I dose escalation safety study of nanoparticulate paclitaxel (CTI 52010) in normal dogs.

    Science.gov (United States)

    Axiak, Sandra M; Selting, Kim A; Decedue, Charles J; Henry, Carolyn J; Tate, Deborah; Howell, Jahna; Bilof, K James; Kim, Dae Y

    2011-01-01

    Paclitaxel is highly effective in the treatment of many cancers in humans, but cannot be routinely used in dogs as currently formulated due to the exquisite sensitivity of this species to surfactant-solubilizing agents. CTI 52010 is a formulation of nanoparticulate paclitaxel consisting of drug and normal saline. Our objectives were to determine the maximally tolerated dose, dose-limiting toxicities, and pharmacokinetics of CTI 52010 administered intravenously to normal dogs. Three normal adult hound dogs were evaluated by physical examination, complete blood count, chemistry profile, and urinalysis. Dogs were treated with staggered escalating dosages of CTI 52010 with a 28-day washout. All dogs were treated with a starting dosage of 40 mg/m(2), and subsequent dosages were escalated at 50% (dog 1), 100% (dog 2), or 200% (dog 3) with each cycle, to a maximum of 240 mg/m(2). Dogs were monitored by daily physical assessment and weekly laboratory evaluation. Standard criteria were used to grade adverse events. Plasma was collected at regular intervals to determine pharmacokinetics. Dogs were euthanized humanely, and necropsy was performed one week after the last treatment. The dose-limiting toxicity was grade 4 neutropenia and the maximum tolerated dosage was 120 mg/m(2). Grade 1-2 gastrointestinal toxicity was noted at higher dosages. Upon post mortem evaluation, no evidence of organ (liver, kidney, spleen) toxicity was noted. CTI 52010 was well tolerated when administered intravenously to normal dogs. A starting dosage for a Phase I/II trial in tumor-bearing dogs is 80 mg/m(2).

  9. Orchid flowers tolerance to gamma-radiation

    International Nuclear Information System (INIS)

    Kikuchi, Olivia Kimiko

    2000-01-01

    Cut flowers are fresh goods that may be treated with fumigants such as methyl bromide to meet the needs of the quarantine requirements of importing countries. Irradiation is a non-chemical alternative to substitute the methyl bromide treatment of fresh products. In this research, different cut orchids were irradiated to examine their tolerance to gamma-rays. A 200 Gy dose did inhibit the Dendrobium palenopsis buds from opening, but did not cause visible damage to opened flowers. Doses of 800 and 1000 Gy were damaging because they provoked the flowers to drop from the stem. Cattleya irradiated with 750 Gy did not show any damage, and were therefore eligible for the radiation treatment. Cymbidium tolerated up to 300 Gy and above this dose dropped prematurely. On the other hand, Oncydium did not tolerate doses above 150 Gy.(author)

  10. Orchid flowers tolerance to gamma-radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Olivia Kimiko E-mail: okikuchi@net.ipen.br

    2000-03-01

    Cut flowers are fresh goods that may be treated with fumigants such as methyl bromide to meet the needs of the quarantine requirements of importing countries. Irradiation is a non-chemical alternative to substitute the methyl bromide treatment of fresh products. In this research, different cut orchids were irradiated to examine their tolerance to gamma-rays. A 200 Gy dose did inhibit the Dendrobium palenopsis buds from opening, but did not cause visible damage to opened flowers. Doses of 800 and 1000 Gy were damaging because they provoked the flowers to drop from the stem. Cattleya irradiated with 750 Gy did not show any damage, and were therefore eligible for the radiation treatment. Cymbidium tolerated up to 300 Gy and above this dose dropped prematurely. On the other hand, Oncydium did not tolerate doses above 150 Gy.(author)

  11. The Radiation Dose-Response of the Human Spinal Cord

    International Nuclear Information System (INIS)

    Schultheiss, Timothy E.

    2008-01-01

    Purpose: To characterize the radiation dose-response of the human spinal cord. Methods and Materials: Because no single institution has sufficient data to establish a dose-response function for the human spinal cord, published reports were combined. Requisite data were dose and fractionation, number of patients at risk, number of myelopathy cases, and survival experience of the population. Eight data points for cervical myelopathy were obtained from five reports. Using maximum likelihood estimation correcting for the survival experience of the population, estimates were obtained for the median tolerance dose, slope parameter, and α/β ratio in a logistic dose-response function. An adequate fit to thoracic data was not possible. Hyperbaric oxygen treatments involving the cervical cord were also analyzed. Results: The estimate of the median tolerance dose (cervical cord) was 69.4 Gy (95% confidence interval, 66.4-72.6). The α/β = 0.87 Gy. At 45 Gy, the (extrapolated) probability of myelopathy is 0.03%; and at 50 Gy, 0.2%. The dose for a 5% myelopathy rate is 59.3 Gy. Graphical analysis indicates that the sensitivity of the thoracic cord is less than that of the cervical cord. There appears to be a sensitizing effect from hyperbaric oxygen treatment. Conclusions: The estimate of α/β is smaller than usually quoted, but values this small were found in some studies. Using α/β = 0.87 Gy, one would expect a considerable advantage by decreasing the dose/fraction to less than 2 Gy. These results were obtained from only single fractions/day and should not be applied uncritically to hyperfractionation

  12. Theoretical considerations for SRAM total-dose hardening

    International Nuclear Information System (INIS)

    Francis, P.; Flandre, D.; Colinge, J.P.

    1995-01-01

    The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented

  13. Effects of Minimum and Maximum Doses of Furosemide on Fractional Shortening Parameter in Echocardiography of the New Zealand White Rabbit

    Directory of Open Access Journals (Sweden)

    Roham Vali, Mohammad Nasrollahzadeh Masouleh* and Siamak Mashhady Rafie1

    2013-04-01

    Full Text Available There is no data on the effect of maximum and minimum doses of furosemide on heart's work performance and amount of fractional shortening (FS in echocardiography of rabbit. This study was designed to validate probability of the mentionable effect. Twenty-four healthy female New Zealand white rabbits were divided into four equal groups. Maximum and minimum doses of furosemide were used for the first and second groups and the injection solution for the third and fourth groups was sodium chloride 0.9% which had the same calculated volumes of furosemide for the first two groups, respectively. The left ventricle FS in statutory times (0, 2, 5, 15, 30 minutes was determined by echocardiography. Measurements of Mean±SD, maximum and minimum amounts for FS values in all groups before injection and in statutory times were calculated. Statistical analysis revealed non-significant correlation between the means of FS. The results of this study showed that furosemide can be used as a diuretic agent for preparing a window approach in abdominal ultrasonography examination with no harmful effect on cardiac function.

  14. Brachial plexus dose tolerance in head and neck cancer patients treated with sequential intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Thomas, Tarita O; Refaat, Tamer; Choi, Mehee; Bacchus, Ian; Sachdev, Sean; Rademaker, Alfred W; Sathiaseelan, Vythialingam; Karagianis, Achilles; Mittal, Bharat B

    2015-01-01

    We aimed to study the radiation induced brachial plexopathy in patients with head and neck squamous cell carcinoma (HNSCC) treated with Sequential Intensity Modulated Radiation Therapy (S-IMRT). This IRB approved study included 68 patients with HNSCC treated consecutively. Detailed dose volume histogram data was generated for ipsilateral and contralateral brachial plexus (BP) volumes receiving a specified dose (Vds) i.e. V50-V75 and dose in Gray covering specified percent of BP volume (Dvs) i.e. D5-D30 and maximum point doses (Dmax). To assess BP injury all patients’ charts were reviewed in detail for sign and symptoms of BP damage. Post-hoc comparisons were done using Tukey-Kramer method to account for multiple significance testing. The mean and maximum doses to BP were significantly different (p < .05) based on tumor site, nodal status and tumor stage. The mean volume to the ipsilateral BP for V50, V60, V70, and V75 were 7.01 cc, 4.37 cc, 1.47 cc and 0.24 cc, respectively. The mean dose delivered to ≤5% of ipsilateral BP was 68.70 Gy (median 69.5Gy). None of the patients had acute or late brachial plexopathy or any other significant neurological complications, with a minimum follow up of two years (mean 54 months). In this study cohort, at a minimum of two-years follow up, the mean dose of 68.7Gy, a median dose to 69.5Gy to ≤5% of ipsilateral BP, and a median Dmax of 72.96Gy did not result in BP injury when patients were treated with S-IMRT technique. However, longer follow up is needed

  15. Individualized Dose Prescription for Hypofractionation in Advanced Non-Small-Cell Lung Cancer Radiotherapy: An in silico Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Aswin L.; Troost, Esther G.C.; Huizenga, Henk; Kaanders, Johannes H.A.M. [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Bussink, Johan, E-mail: j.bussink@rther.umcn.nl [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands)

    2012-08-01

    Purpose: Local tumor control and outcome remain poor in patients with advanced non-small-cell lung cancer (NSCLC) treated by external beam radiotherapy. We investigated the therapeutic gain of individualized dose prescription with dose escalation based on normal tissue dose constraints for various hypofractionation schemes delivered with intensity-modulated radiation therapy. Methods and Materials: For 38 Stage III NSCLC patients, the dose level of an existing curative treatment plan with standard fractionation (66 Gy) was rescaled based on dose constraints for the lung, spinal cord, esophagus, brachial plexus, and heart. The effect on tumor total dose (TTD) and biologic tumor effective dose in 2-Gy fractions (TED) corrected for overall treatment time (OTT) was compared for isotoxic and maximally tolerable schemes given in 15, 20, and 33 fractions. Rescaling was accomplished by altering the dose per fraction and/or the number of fractions while keeping the relative dose distribution of the original treatment plan. Results: For 30 of the 38 patients, dose escalation by individualized hypofractionation yielded therapeutic gain. For the maximally tolerable dose scheme in 33 fractions (MTD{sub 33}), individualized dose escalation resulted in a 2.5-21% gain in TTD. In the isotoxic schemes, the number of fractions could be reduced with a marginal increase in TED. For the maximally tolerable dose schemes, the TED could be escalated up to 36.6%, and for all patients beyond the level of the isotoxic and the MTD{sub 33} schemes (range, 3.3-36.6%). Reduction of the OTT contributed to the therapeutic gain of the shortened schemes. For the maximally tolerable schemes, the maximum esophageal dose was the dominant dose-limiting constraint in most patients. Conclusions: This modeling study showed that individualized dose prescription for hypofractionation in NSCLC radiotherapy, based on scaling of existing treatment plans up to normal tissue dose constraints, enables dose

  16. An FDA oncology analysis of CD3 bispecific constructs and first-in-human dose selection.

    Science.gov (United States)

    Saber, Haleh; Del Valle, Pedro; Ricks, Tiffany K; Leighton, John K

    2017-11-01

    We retrospectively examined the nonclinical studies conducted with 17 CD3 bispecific constructs in support of first-in-human (FIH) trials in oncology. We also collected information on the design of dose-finding clinical trials. Sponsors have used different MABEL approaches for FIH dose selection. To better assess acceptable approaches, FIH doses were computed from nonclinical studies and compared to the maximum tolerated doses (MTDs) in patients, to the highest human doses (HHDs) when an MTD was not identified, or to the recommended human dose (RHD) for blinatumomab. We concluded that approaches based on receptor occupancy, highest non-severely toxic dose, or no-observed adverse effect level are not acceptable for selecting the FIH dose as they resulted in doses close to or above the MTDs, HHDs, or the RHD. A FIH dose corresponding to 10%-30% pharmacologic activity (PA) was an acceptable approach. A FIH dose corresponding to 50% PA was acceptable for all except one construct, potentially due to its biological or structural properties. The most common toxicities in animals and patients were those related to cytokine release. Doses were better tolerated when intra-animal or intra-patient dose escalation was used. Exposing naïve patients to an MTD achieved with intra-patient dose escalation design may be unsafe. Published by Elsevier Inc.

  17. Biochemical Tolerance During Low Dose Propylene Glycol Exposure in Neonates: A Formulation-Controlled Evaluation

    Directory of Open Access Journals (Sweden)

    Aida Kulo

    2012-07-01

    Full Text Available Background and purpose of the study: Propylene glycol (PG is a frequently co-administered solvent in formulations administered to neonates, but reports on its (intolerance are limited. We aimed to report on renal, metabolic and hepatic tolerance before, during and following intravenous (iv PG-paracetamol exposure and compared these data with similar datasets reported in literature on neonates exposed to PG without paracetamol or paracetamol without PG.Methods: Renal (diuresis, creatinemia, sodium, metabolic (Base Excess, Anion Gap, lactate, bicarbonate and hepatic (liver enzymes, bilirubinemia indicators before, during and following iv paracetamol-PG exposure in neonates as included in the PARANEO (paracetamol in neonates study (intra-individual trends, ANOVA were collected and analysed.Comparison with observations collected in cases exposed to either iv phenobarbital-PG or iv paracetamol-mannitol (inter-individual comparison, Mann Whitney-U test were made. Results: PG exposure (median 34.1 mg/kg/24 h did not affect postnatal renal, metabolic and hepatic adaptations in 60 cases exposed to paracetamol-PG. These indicators were similar when compared to 29 cases exposed to phenobarbital- PG or 172 cases exposed to paracetamol-mannitol.Major conclusion: Based on observations in 89 neonates, low dose PG exposure was tolerated well. Studies on PG pharmacokinetics and its covariates are needed to estimate the upper level of PG tolerance in neonates.

  18. Estimated radiological doses to the maximumly exposed individual and downstream populations from releases of tritium, strontium-90, ruthenium-106, and cesium-137 from White Oak Dam

    International Nuclear Information System (INIS)

    Little, C.A.; Cotter, S.J.

    1980-01-01

    Concentrations of tritium, 90 Sr, 106 Ru, and 137 Cs in the Clinch River for 1978 were estimated by using the known 1978 releases of these nuclides from the White Oak Dam and diluting them by the integrated annual flow rate of the Clinch River. Estimates of 50-year dose commitment to a maximumly exposed individual were calculated for both aquatic and terestrial pathways of exposure. The maximumly exposed individual was assumed to reside at the mouth of White Oak Creek where it enters the Clinch River and obtain all foodstuffs and drinking water at that location. The estimated total-body dose from all pathways to the maximumly exposed individual as a result of 1978 releases was less than 1% of the dose expected from natural background. Using appropriate concentrations of to subject radionuclides diluted downstream, the doses to populations residing at Harriman, Kingston, Rockwood, Spring City, Soddy-Daisy, and Chattanooga were calculated for aquatic exposure pathways. The total-body dose estimated for aquatic pathways for the six cities was about 0.0002 times the expected dose from natural background. For the pathways considered in this report, the nuclide which contributed the largest fraction of dose was 90 Sr. The largest dose delivered by 90 Sr was to the bone of the subject individual or community

  19. Efficacy and tolerability of a high loading dose (25,000 IU weekly) vitamin D3 supplementation in obese children with vitamin D insufficiency/deficiency

    NARCIS (Netherlands)

    Radhakishun, Nalini N E; van Vliet, Mariska; Poland, Dennis C W; Weijer, Olivier; Beijnen, Jos H; Brandjes, Dees P M; Diamant, Michaela; von Rosenstiel, Ines A

    2014-01-01

    BACKGROUND: The recommended dose of vitamin D supplementation of 400 IU/day might be inadequate to treat obese children with vitamin D insufficiency. Therefore, we tested the efficacy and tolerability of a high loading dose vitamin D3 supplementation of 25,000 IU weekly in multiethnic obese

  20. The ICRP Proposed Maximum Public Dose Constraints of o.3 mSv/y: a Major Issue for the Nuclear Industry

    International Nuclear Information System (INIS)

    Saint-Pierre, S.; Coates, R.

    2004-01-01

    The International Commission on Radiological Protection (ICRP) is currently developing a new set of Recommendations on Radiological Protection. A value of 0.3mSv/y for the maximum public dose constraint has been discussed by ICRP. This value represents a major concern for the nuclear industry at large. The primary issue arises from the lack of any new scientific evidence on public health effects from ionising radiation to support, in practice, the proposed reduction by about a factor of 3 (from 1 to 0.3 mSv/y) of the upper bound value for public dose impact from a nuclear activity or site. Such a change would create a de facto limit on public exposure from specific sources at a dose level of about one tenth of average natural background and an even smaller fraction of the typical range of background exposures and exposures from medical sources. This cannot be justified on public health grounds. The WNA supports ICRP's renewed intention, as expressed at the NEA-ICRP Stakeholder Forum in Lanzarote (April 2003), to retain the concept of a public dose limit at 1 mSv/y. We strongly believe that the current system comprising of the dose limit and the ALARA Principle provides the necessary flexibility and tools for regulators to address all situations in all countries. The WNA consider that the question of setting an upper bound dose constraint (below 1 mSv/y) at the country/site specific level is best left for discussion and agreement between the local stakeholders rather than at an international level. When considering the potential practical implications of a maximum dose constraint, it is important to look beyond the very low off-site dose impacts (on the public) resulting from annual routine radioactive discharges of nuclear industrial sites. There are many off-site and on-site practical situations, related to public exposures (both workers and the public) and worker classification as well as activities such transportation, decommissioning and site remediation, for

  1. The ICRP Proposed Maximum Public Dose Constraints of o.3 mSv/y: a Major Issue for the Nuclear Industry

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Pierre, S.; Coates, R.

    2004-07-01

    The International Commission on Radiological Protection (ICRP) is currently developing a new set of Recommendations on Radiological Protection. A value of 0.3mSv/y for the maximum public dose constraint has been discussed by ICRP. This value represents a major concern for the nuclear industry at large. The primary issue arises from the lack of any new scientific evidence on public health effects from ionising radiation to support, in practice, the proposed reduction by about a factor of 3 (from 1 to 0.3 mSv/y) of the upper bound value for public dose impact from a nuclear activity or site. Such a change would create a de facto limit on public exposure from specific sources at a dose level of about one tenth of average natural background and an even smaller fraction of the typical range of background exposures and exposures from medical sources. This cannot be justified on public health grounds. The WNA supports ICRP's renewed intention, as expressed at the NEA-ICRP Stakeholder Forum in Lanzarote (April 2003), to retain the concept of a public dose limit at 1 mSv/y. We strongly believe that the current system comprising of the dose limit and the ALARA Principle provides the necessary flexibility and tools for regulators to address all situations in all countries. The WNA consider that the question of setting an upper bound dose constraint (below 1 mSv/y) at the country/site specific level is best left for discussion and agreement between the local stakeholders rather than at an international level. When considering the potential practical implications of a maximum dose constraint, it is important to look beyond the very low off-site dose impacts (on the public) resulting from annual routine radioactive discharges of nuclear industrial sites. There are many off-site and on-site practical situations, related to public exposures (both workers and the public) and worker classification as well as activities such transportation, decommissioning and site remediation

  2. [Value of early application of different doses of amino acids in parenteral nutrition among preterm infants].

    Science.gov (United States)

    Liu, Zhi-Juan; Liu, Guo-Sheng; Chen, Yong-Ge; Zhang, Hui-Li; Wu, Xue-Fen

    2015-01-01

    To study the short-term response and tolerance of different doses of amino acids in parenteral nutrition among preterm infants. This study included 86 preterm infants who had a birth weight between 1 000 to 2 000 g and were admitted to the hospital within 24 hours of birth between March 2013 and June 2014. According to the early application of different doses of amino acids, they were randomized into low-dose group (n=29, 1.0 g/kg per day with an increase of 1.0 g/kg daily and a maximum of 3.5 g/kg per day), medium-dose group (n=28, 2.0 g/kg per day with an increase of 1.0 g/kg daily and a maximum of 3.7 g/kg per day), and high-dose group (n=29, 3.0 g/kg per day with an increase of 0.5-1.0 g/kg daily and a maximum of 4.0 g/kg per day). Other routine parenteral nutrition and enteral nutrition support were also applied. The maximum weight loss was lower and the growth rate of head circumference was greater in the high-dose group than in the low-dose group (Pnutrition, shorter duration of hospital stay, and less hospital cost than those in the low-dose group (P0.05). Parenteral administration of high-dose amino acids in preterm infants within 24 hours after birth can improve the short-term nutritional status of preterm infants, but there is a transient increase in BUN level.

  3. Overcoming beta-agonist tolerance: high dose salbutamol and ipratropium bromide. Two randomised controlled trials

    Directory of Open Access Journals (Sweden)

    Haney Sarah

    2007-03-01

    Full Text Available Abstract Background Asthmatics treated with long-acting beta-agonists have a reduced bronchodilator response to moderate doses of inhaled short acting beta-agonists during acute bronchoconstriction. It is not known if the response to higher doses of nebulised beta-agonists or other bronchodilators is impaired. We assessed the effect of long-acting beta-agonist treatment on the response to 5 mg nebulised salbutamol and to ipratropium bromide. Methods Two double-blind, placebo-controlled, crossover studies of inhaled formoterol 12 μg twice daily in patients with asthma. High-dose salbutamol: 36 hours after the last dose of 1 week of formoterol or placebo treatment, 11 subjects inhaled methacholine to produce a 20% fall in FEV1. Salbutamol 5 mg was then administered via nebuliser and the FEV1 was monitored for 20 minutes. Ipratropium: 36 hours after the last dose of 1 week of formoterol or placebo treatment, 11 subjects inhaled 4.5% saline to produce a 20% fall in FEV1. Salbutamol 200 μg or ipratropium bromide 40 μg was then inhaled and the FEV1 was monitored for 30 minutes. Four study arms compared the response to each bronchodilator after formoterol and placebo. Analyses compared the area under the bronchodilator response curves, adjusting for changes in pre-challenge FEV1, dose of provocational agent and FEV1 fall during the challenge procedure. Results The response to nebulised salbutamol was 15% lower after formoterol therapy compared to placebo (95% confidence 5 to 25%, p = 0.008. The response to ipratropium was unchanged. Conclusion Long-acting beta-agonist treatment induces tolerance to the bronchodilator effect of beta-agonists, which is not overcome by higher dose nebulised salbutamol. However, the bronchodilator response to ipratropium bromide is unaffected.

  4. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    International Nuclear Information System (INIS)

    Cao, Y.; Leroux, P.; De Cock, W.; Steyaert, M.

    2011-01-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma (ΔΣ) TDC structure is proposed. The converter, implemented in 0.13 μm, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm 2 . Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g m biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  5. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Y. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Leroux, P. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); ICT-RELIC Div., Katholieke Hogeschool Kempen, B-2440 Geel (Belgium); De Cock, W. [SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Steyaert, M. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium)

    2011-07-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma ({Delta}{Sigma}) TDC structure is proposed. The converter, implemented in 0.13 {mu}m, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm{sup 2}. Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g{sub m} biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  6. Dry powder dosing in liquid vehicles: ocular tolerance and scintigraphic evaluation of a perfluorocarbon suspension.

    Science.gov (United States)

    Zhu, Y; Wilson, C G; Meadows, D; Olejnik, O; Frier, M; Washington, N; Musson, R

    1999-11-30

    The ocular tolerance and precorneal disposition of 99mTc-labelled sterile carbon-perfluorodecalin (PFD) and carbon-aqueous suspensions were examined in a cohort of healthy volunteers. Formulations were prepared in PFD or saline using charcoal particles, radiolabelled with [99mTc]diethylenetriaminepentaacetic acid (DTPA) under GMP conditions. Colloidal silicon dioxide was used as a suspending agent. Ocular tolerance was examined following the instillation of each formulation to the eyes of 12 volunteers. The precorneal distribution of both formulations in man was monitored using gamma scintigraphy. Dynamic and static data acquisitions were taken over a period of 150 min after dosing. Carbon particulates suspended in PFD did not show any irritation to the eye. Administration of PFD formulation in man produced a significant increase in ocular retention over a saline formulation (mean residence time (MRT)=157+/-42 and 0.29+/-0.08 min, respectively, P=0.0001). Distribution of the carbon in man followed the same pattern as in a previous reported study in animals. The carbon deposited uniformly along the lid margin in the case of the PFD vehicle, whereas it agglomerated following dosing in the saline vehicle and was ejected from the eye. The novel non-aqueous vehicle system is able to significantly improve the ocular retention of charcoal particles in man and provides a unique distribution of the particles in the eye, which suggests a potential for the PFD system for the treatment of periocular diseases.

  7. Oral Tolerance: Therapeutic Implications for Autoimmune Diseases

    Directory of Open Access Journals (Sweden)

    Ana M. C. Faria

    2006-01-01

    Full Text Available Oral tolerance is classically defined as the suppression of immune responses to antigens (Ag that have been administered previously by the oral route. Multiple mechanisms of tolerance are induced by oral Ag. Low doses favor active suppression, whereas higher doses favor clonal anergy/deletion. Oral Ag induces Th2 (IL-4/IL-10 and Th3 (TGF-β regulatory T cells (Tregs plus CD4+CD25+ regulatory cells and LAP+T cells. Induction of oral tolerance is enhanced by IL-4, IL-10, anti-IL-12, TGF-β, cholera toxin B subunit (CTB, Flt-3 ligand, anti-CD40 ligand and continuous feeding of Ag. In addition to oral tolerance, nasal tolerance has also been shown to be effective in suppressing inflammatory conditions with the advantage of a lower dose requirement. Oral and nasal tolerance suppress several animal models of autoimmune diseases including experimental allergic encephalomyelitis (EAE, uveitis, thyroiditis, myasthenia, arthritis and diabetes in the nonobese diabetic (NOD mouse, plus non-autoimmune diseases such as asthma, atherosclerosis, colitis and stroke. Oral tolerance has been tested in human autoimmune diseases including MS, arthritis, uveitis and diabetes and in allergy, contact sensitivity to DNCB, nickel allergy. Positive results have been observed in phase II trials and new trials for arthritis, MS and diabetes are underway. Mucosal tolerance is an attractive approach for treatment of autoimmune and inflammatory diseases because of lack of toxicity, ease of administration over time and Ag-specific mechanism of action. The successful application of oral tolerance for the treatment of human diseases will depend on dose, developing immune markers to assess immunologic effects, route (nasal versus oral, formulation, mucosal adjuvants, combination therapy and early therapy.

  8. Normal tissue tolerance to external beam radiation therapy: Esophagus; Dose de tolerance a l'irradiation des tissus sains: l'oesophage

    Energy Technology Data Exchange (ETDEWEB)

    Bera, G.; Pointreau, Y. [Clinique d' oncologie-radiotherapie, centre Henry-S.-Kaplan, hopital Bretonneau, CHU de Tours, 37 - Tours (France); Denis, F.; Dupuis, O. [Centre Jean-Bernard, clinique Victor-Hugo, 72 - Le-Mans (France); Orain, I. [Service d' anatomie et cytologie pathologiques, hopital Trousseau, CHU de Tours, 37 - Tours (France); Crehange, G. [Departement de radiotherapie, centre Georges-Francois-Leclerc, 21 - Dijon (France)

    2010-07-15

    The esophagus is a musculo-membranous tube through which food passes from the pharynx to the stomach. Due to its anatomical location, it can be exposed to ionizing radiation in many external radiotherapy indications. Radiation-induced esophageal mucositis is clinically revealed by dysphagia and odynophagia, and usually begins 3 to 4 weeks after the start of radiation treatment. With the rise of multimodality treatments (e.g., concurrent chemoradiotherapy, dose escalation and accelerated fractionation schemes), esophageal toxicity has become a significant dose-limiting issue. Understanding the predictive factors of esophageal injury may improve the optimal delivery of treatment plans. It may help to minimize the risks, hence increasing the therapeutic ratio. Based on a large literature review, our study describes both early and late radiation-induced esophageal injuries and highlights some of the predictive factors for cervical and thoracic esophagus toxicity. These clinical and dosimetric parameters are numerous but none is consensual. The large number of dosimetric parameters strengthens the need of an overall analysis of the dose/volume histograms. The data provided is insufficient to recommend their routine use to prevent radiation-induced esophagitis. Defining guidelines for the tolerance of the esophagus to ionizing radiation remains essential for a safe and efficient treatment. (authors)

  9. A novel dose uncertainty model and its application for dose verification

    International Nuclear Information System (INIS)

    Jin Hosang; Chung Heetaek; Liu Chihray; Palta, Jatinder; Suh, Tae-Suk; Kim, Siyong

    2005-01-01

    Based on statistical approach, a novel dose uncertainty model was introduced considering both nonspatial and spatial dose deviations. Non-space-oriented uncertainty is mainly caused by dosimetric uncertainties, and space-oriented dose uncertainty is the uncertainty caused by all spatial displacements. Assuming these two parts are independent, dose difference between measurement and calculation is a linear combination of nonspatial and spatial dose uncertainties. Two assumptions were made: (1) the relative standard deviation of nonspatial dose uncertainty is inversely proportional to the dose standard deviation σ, and (2) the spatial dose uncertainty is proportional to the gradient of dose. The total dose uncertainty is a quadratic sum of the nonspatial and spatial uncertainties. The uncertainty model provides the tolerance dose bound for comparison between calculation and measurement. In the statistical uncertainty model based on a Gaussian distribution, a confidence level of 3σ theoretically confines 99.74% of measurements within the bound. By setting the confidence limit, the tolerance bound for dose comparison can be made analogous to that of existing dose comparison methods (e.g., a composite distribution analysis, a γ test, a χ evaluation, and a normalized agreement test method). However, the model considers the inherent dose uncertainty characteristics of the test points by taking into account the space-specific history of dose accumulation, while the previous methods apply a single tolerance criterion to the points, although dose uncertainty at each point is significantly different from others. Three types of one-dimensional test dose distributions (a single large field, a composite flat field made by two identical beams, and three-beam intensity-modulated fields) were made to verify the robustness of the model. For each test distribution, the dose bound predicted by the uncertainty model was compared with simulated measurements. The simulated

  10. Microbiological efficacy and tolerability of a single-dose regimen of 1 g of ceftriaxone in men with gonococcal urethritis.

    Science.gov (United States)

    Ito, Shin; Yasuda, Mitsuru; Hatazaki, Kyoko; Mizutani, Kosuke; Tsuchiya, Tomohiro; Yokoi, Shigeaki; Nakano, Masahiro; Deguchi, Takashi

    2016-09-01

    We treated men with gonococcal urethritis with a single-dose regimen of 1 g of ceftriaxone, which is recommended as the first-line treatment for gonorrhoea in Japan, to determine its microbiological outcomes and tolerability. We enrolled 255 men with gonococcal urethritis and treated them with a single-dose regimen of 1 g of ceftriaxone. We evaluated its microbiological outcomes and tolerability. We also determined ceftriaxone MICs for pretreatment isolates of Neisseria gonorrhoeae collected from the patients. The microbiological efficacy of the ceftriaxone regimen, which was determined between 5 and 9 days after treatment in 111 men based on the Japanese guideline for clinical research on antimicrobial agents in urogenital infections, was 100%. In the 194 men who returned to the clinic between 2 and 41 days after treatment, 191 (98.5%; 95% CI 96.8%-100%) were negative for N. gonorrhoeae after treatment. Ceftriaxone MICs determined for 136 pretreatment isolates obtained from these 194 men ranged from 0.001 to 0.25 mg/L. One isolate persisting after treatment exhibited a ceftriaxone MIC of 0.008 mg/L. For two isolates persisting after treatment, ceftriaxone MICs were not determined. Seven adverse events were observed in 7 (3.2%) of the 220 men treated with the ceftriaxone regimen. Four men had diarrhoea classified as grade 1. Three had urticaria during ceftriaxone administration, with one event classified as grade 1 and two events classified as grade 3. A single-dose regimen of 1 g of ceftriaxone was microbiologically effective against gonococcal urethritis and was safe and tolerable. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Two-dose-level confirmatory study of the pharmacokinetics and tolerability of everolimus in Chinese patients with advanced solid tumors

    Directory of Open Access Journals (Sweden)

    Jappe Annette

    2011-01-01

    Full Text Available Abstract Background This phase I, randomized, multicenter, open-label study investigated the pharmacokinetics, safety, and efficacy of the oral mammalian target of rapamycin inhibitor everolimus in Chinese patients with advanced solid tumors. Methods A total of 24 patients with advanced breast cancer (n = 6, gastric cancer (n = 6, non-small cell lung cancer (n = 6, or renal cell carcinoma (n = 6 who were refractory to/unsuitable for standard therapy were randomized 1:1 to oral everolimus 5 or 10 mg/day. Primary end points were pharmacokinetic parameters and safety and tolerability. Pharmacokinetic 24-h profiles were measured on day 15; trough level was measured on days 2, 8, 15, 16, and 22. Tolerability was assessed continuously. This final analysis was performed after all patients had received 6 months of study drug or had discontinued. Results Everolimus was absorbed rapidly; median Tmax was 3 h (range, 1-4 and 2 h (range, 0.9-6 in the 5 and 10 mg/day groups, respectively. Pharmacokinetic parameters increased dose proportionally from the 5 and 10 mg/day doses. Steady-state levels were achieved by day 8 or earlier. The most common adverse events suspected to be related to everolimus therapy were increased blood glucose (16.7% and 41.7% and fatigue (16.7% and 33.3% in the everolimus 5 and 10 mg/day dose cohorts, respectively. Best tumor response was stable disease in 10 (83% and 6 (50% patients in the 5 and 10 mg/day groups, respectively. Conclusions Everolimus 5 or 10 mg/day was well tolerated in Chinese patients with advanced solid tumors. The observed safety and pharmacokinetic profile of everolimus from this study were consistent with previous studies. Trial registration Chinese Health Authorities 2008L09346

  12. Dose effect comparisons between HFR and BMRR irradiated dogs with respect to healthy tissue tolerance

    International Nuclear Information System (INIS)

    Huiskamp, R.; Philipp, K.H.I.; Gavin, P.R.; Wheeler, F.J.; Siefert, A.

    1993-01-01

    Epithermal neutron beams are being developed for the application of boron neutron capture therapy (BNCT) of deep seated tumors, like glioblastoma and astrocytomas, through the intact skin. Epithermal neutrons will be moderated by the tissue mass between skin and tumour to produce the thermal neutrons necessary for the 10 B(n,α) 7 Li reaction in the target tissue. Although the neutron capture cross-sections of elements in normal tissue are several orders of magnitude lower that for boron, the high abundance of hydrogen and nitrogen will cause a significant contribution to the total absorbed radiation dose through the 1 H(n,γ) 2 H and the 14 N(n,p) 14 C reaction, respectively. Due to inevitable incomplete filtration, an epithermal beam will also contain a fast neutron component, i.e. neutrons with energies ≥ 10 keV, and a γ-photon component originating from the reactor and produced in structural and filter materials. Therefore, the resultant radiation consists of a complex of low and high LET radiation of which the constitutents vary rapidly with depth in tissue. Based on the ongoing canine healthy tissue tolerance study at the Brookhaven Medical Research Reactor (BMRR) using the epithermal beam without BSH, the relative biological effectiveness (RBE) of the fast neutron beam component has been determined for skin reactions. In addition, a open-quotes compound factorclose quotes, i.e geometry x RBE, for the 10 B(n,α) 7 Li reaction was derived for dogs irradiated at the BMRR with the epithermal beam and BSH (Gavin et al.). Currently, a healthy tissue tolerance study with BSH is being carried out at the HB11 epithermal beam of the High Flux Reactor at Petten. The present paper describes preliminary dose effect comparisons between High Flux Reactor (HFR) and BMRR irradiated dogs with respect to healthy tissue tolerance in order to refine the BSH compound factors and the fast neutron RBE for skin and brain

  13. Reversal of oxycodone and hydrocodone tolerance by diazepam.

    Science.gov (United States)

    Gonek, Maciej; Akbarali, Hamid I; Henderson, Graeme; Dewey, William L

    2017-11-01

    The Centers for Disease Control has declared opioid abuse to be an epidemic. Overdose deaths are largely assumed to be the result of excessive opioid consumption. In many of these cases, however, opioid abusers are often polydrug abusers. Benzodiazepines are one of the most commonly co-abused substances and pose a significant risk to opioid users. In 2016, the FDA required boxed warnings - the FDA's strongest warning - for prescription opioid analgesics and benzodiazepines about the serious risks associated with using these medications at the same time. The point of our studies was to evaluate the interactions between these two classes of drugs. We investigated whether diazepam adds to the depressant effects of opioids or do they alter the levels of tolerance to opioids. In the present study, we have found that the antinociceptive tolerance that developed to repeated administration of oxycodone was reversed by an acute dose of diazepam. Antinociceptive tolerance to hydrocodone was also reversed by acute injection of diazepam; however, a fourfold higher dose of diazepam was required when compared to reversal of oxycodone-induced tolerance. These doses of diazepam did not potentiate the acute antinociceptive effect of either opioid. The same dose of diazepam that reversed oxycodone antinociceptive tolerance also reversed oxycodone locomotor tolerance while having no potentiating effects. These studies show that diazepam does not potentiate the acute effect of prescription opioids but reverses the tolerance developed after chronic administration of the drugs. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Pre-operative combined 5-FU, low dose leucovorin, and sequential radiation therapy for unresectable rectal cancer

    International Nuclear Information System (INIS)

    Minsky, B.D.; Cohen, A.M.; Kemeny, N.; Enker, W.E.; Kelsen, D.P.; Schwartz, G.; Saltz, L.; Dougherty, J.; Frankel, J.; Wiseberg, J.

    1993-01-01

    The authors performed a Phase 1 trial to determine the maximum tolerated dose of combined pre-operative radiation (5040 cGy) and 2 cycles (bolus daily x 5) of 5-FU and low dose LV (20 mg/m2), followed by surgery and 10 cycles of post-operative LV/5-FU in patients with unresectable primary or recurrent rectal cancer. Twelve patients were entered. The initial dose of 5-FU was 325 mg/m2. 5-FU was to be escalated while the LV remained constant at 20 mg/m2. Chemotherapy began on day 1 and radiation on day 8. The post-operative chemotherapy was not dose escalated; 5-FU: 425 mg/m2 and LV: 20 mg/m2. The median follow-up was 14 months (7--16 months). Following pre-operative therapy, the resectability rate with negative margins was 91% and the pathologic complete response rate was 9%. For the combined modality segment (preoperative) the incidence of any grade 3+ toxicity was diarrhea: 17%, dysuria: 8%, mucositis: 8%, and erythema: 8%. The median nadir counts were WBC: 3.1, HGB: 8.8, and PLT: 153000. The maximum tolerated dose of 5-FU for pre-operative combined LV/5-FU/RT was 325 mg/m2 with no escalation possible. Therefore, the recommended dose was less than 325 mg/m2. Since adequate doses of 5-FU to treat systemic disease could not be delivered until at least 3 months (cycle 3) following the start of therapy, the authors do not recommend that this 5-FU, low dose LV, and sequential radiation therapy regimen be used as presently designed. However, given the 91% resectability rate they remain encouraged with this approach. 31 refs., 1 fig., 2 tabs

  15. Effectiveness and gastrointestinal tolerability during conversion and titration with once-daily OROS® hydromorphone extended release in opioid-tolerant patients with chronic low back pain

    Science.gov (United States)

    Hale, Martin E; Nalamachu, Srinivas R; Khan, Arif; Kutch, Michael

    2013-01-01

    Purpose To describe the efficacy and safety of hydromorphone extended-release tablets (OROS hydromorphone ER) during dose conversion and titration. Patients and methods A total of 459 opioid-tolerant adults with chronic moderate to severe low back pain participated in an open-label, 2- to 4-week conversion/titration phase of a double-blind, placebo-controlled, randomized withdrawal trial, conducted at 70 centers in the United States. Patients were converted to once-daily OROS hydromorphone ER at 75% of the equianalgesic dose of their prior total daily opioid dose (5:1 conversion ratio), and titrated as frequently as every 3 days to a maximum dose of 64 mg/day. The primary outcome measure was change in pain intensity numeric rating scale; additional assessments included the Patient Global Assessment and the Roland–Morris Disability Questionnaire scores. Safety assessments were performed at each visit and consisted of recording and monitoring all adverse events (AEs) and serious AEs. Results Mean (standard deviation) final daily dose of OROS hydromorphone ER was 37.5 (17.8) mg. Mean (standard error of the mean [SEM]) numeric rating scale scores decreased from 6.6 (0.1) at screening to 4.3 (0.1) at the final titration visit (mean [SEM] change, −2.3 [0.1], representing a 34.8% reduction). Mean (SEM) change in Patient Global Assessment was −0.6 (0.1), and mean change (SEM) in the Roland–Morris Disability Questionnaire was −2.8 (0.3). Patients achieving a stable dose showed greater improvement than patients who discontinued during titration for each of these measures (P < 0.001). Almost 80% of patients achieving a stable dose (213/268) had a ≥30% reduction in pain. Commonly reported AEs were constipation (15.4%), nausea (11.9%), somnolence (8.7%), headache (7.8%), and vomiting (6.5%); 13.0% discontinued from the study due to AEs. Conclusion The majority of opioid-tolerant patients with chronic low back pain were successfully converted to effective doses of

  16. Disinfestation of agricultural products with electron beams and their radiation tolerance

    International Nuclear Information System (INIS)

    Hayashi, Toru

    1996-01-01

    Some agricultural products contaminated with insect pests are fumigated with methyl bromide for quarantine purposes. However, the use of methyl bromide is preferably restricted because of its ozone depleting effect. Therefore, establishing alternative quarantine techniques is highly desirable; one such technique is exposure to ionizing radiation. Few data are available on the effects of radiation on insect pests other than fruit flies and stored-product insects and on the radiation tolerance of host commodities. Radiation technology as an alternative to methyl bromide fumigation will be used to inactivate not only insects but also mites, spider mites, thrips, nematodes, scales, mealybugs and thrips contaminating fruits, grains, cut flowers, vegetables, timbers, seedlings and seeds. In order to collect data on the effects of irradiation on pests and host commodities, IAEA and FAO have conducted an international project, 'FAO/IAEA Coordinated Research Programme on Irradiation as a Quarantine Treatment of Mites, Nematodes and Insects other than Fruit Fly' since 1992. The project determines the minimum doses necessary to inactivate pests and the maximum doses host commodities tolerate. All pests except nematodes can be inactivated at doses 400Gy or lower. Various varieties of cut flowers and herbs are tolerant to 400Gy of radiation, although some flowers and herbs such as chrysanthemum, rose, lily, calla, anthurium, sweet pea, iris, dill, basil and arugula are intolerant to 200Gy of radiation. Japanese research project on treatment of cut flowers with electron beams carried out mainly by Yokohama Plant Protection Station greatly contributes to these conclusions. Aqueous solution (2%) of sucrose, glucose, fructose or maltose prevents radiation-induced detrimental effects of radiation on chrysanthemums. Sugars reduce radiation-induced physiological deterioration of chrysanthemums. (author)

  17. Normal tissue tolerance to external beam radiation therapy: Adult bone; Dose de tolerance a l'irradiation des tissus sains: l'os chez l'adulte

    Energy Technology Data Exchange (ETDEWEB)

    Sargos, P.; Mamou, N.; Dejean, C.; Henriques de Figueiredo, B.; Kantor, G. [Departement de radiotherapie, Centre regional de lutte contre le cancer, institut Bergonie, 33 - Bordeaux (France); Huchet, A. [Departement de radiotherapie, hopital Saint-Andre, 33 - Bordeaux (France); Italiano, A. [Service d' oncologie medicale, Centre regional de lutte contre le cancer, institut Bergonie, 33 - Bordeaux (France)

    2010-07-15

    Radiation tolerance for bone tissue has been mostly evaluated with regard to bone fracture. Main circumstances are mandibula osteoradionecrosis, hip and costal fracture, and patent or radiologic fractures in the treated volume. After radiation therapy of bone metastasis, the analysis of related radiation fracture is difficult to individualize from a pathologic fracture. Frequency of clinical fracture is less than 5% in the large series or cohorts and is probably under-evaluated for the asymptomatic lesions. Women older than 50 years and with osteoporosis are probably the main population at risk. Dose-effect relations are difficult to qualify in older series. Recent models evaluating radiations toxicity on diaphysa suggest an important risk after 60 Gy, for high dose-fraction and for a large volume. (authors)

  18. Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures

    Science.gov (United States)

    Journy, N; Sinno-Tellier, S; Maccia, C; Le Tertre, A; Pirard, P; Pagès, P; Eilstein, D; Donadieu, J; Bar, O

    2012-01-01

    Objective The study aimed to characterise the factors related to the X-ray dose delivered to the patient's skin during interventional cardiology procedures. Methods We studied 177 coronary angiographies (CAs) and/or percutaneous transluminal coronary angioplasties (PTCAs) carried out in a French clinic on the same radiography table. The clinical and therapeutic characteristics, and the technical parameters of the procedures, were collected. The dose area product (DAP) and the maximum skin dose (MSD) were measured by an ionisation chamber (Diamentor; Philips, Amsterdam, The Netherlands) and radiosensitive film (Gafchromic; International Specialty Products Advanced Materials Group, Wayne, NJ). Multivariate analyses were used to assess the effects of the factors of interest on dose. Results The mean MSD and DAP were respectively 389 mGy and 65 Gy cm−2 for CAs, and 916 mGy and 69 Gy cm−2 for PTCAs. For 8% of the procedures, the MSD exceeded 2 Gy. Although a linear relationship between the MSD and the DAP was observed for CAs (r=0.93), a simple extrapolation of such a model to PTCAs would lead to an inadequate assessment of the risk, especially for the highest dose values. For PTCAs, the body mass index, the therapeutic complexity, the fluoroscopy time and the number of cine frames were independent explanatory factors of the MSD, whoever the practitioner was. Moreover, the effect of technical factors such as collimation, cinematography settings and X-ray tube orientations on the DAP was shown. Conclusion Optimising the technical options for interventional procedures and training staff on radiation protection might notably reduce the dose and ultimately avoid patient skin lesions. PMID:22457404

  19. Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Zanca, F., E-mail: Federica.Zanca@med.kuleuven.be [Department of Radiology, Leuven University Center of Medical Physics in Radiology, UZ Leuven, Herestraat 49, 3000 Leuven, Belgium and Imaging and Pathology Department, UZ Leuven, Herestraat 49, Box 7003 3000 Leuven (Belgium); Jacobs, A. [Department of Radiology, Leuven University Center of Medical Physics in Radiology, UZ Leuven, Herestraat 49, 3000 Leuven (Belgium); Crijns, W. [Department of Radiotherapy, UZ Leuven, Herestraat 49, 3000 Leuven (Belgium); De Wever, W. [Imaging and Pathology Department, UZ Leuven, Herestraat 49, Box 7003 3000 Leuven, Belgium and Department of Radiology, UZ Leuven, Herestraat 49, 3000 Leuven (Belgium)

    2014-07-15

    Purpose: To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. Methods: Data from 50 patients with lung lesions who underwent a CT fluoroscopy-guided biopsy were collected. The CT protocol consisted of a low-kilovoltage (80 kV) protocol used in combination with an algorithm for dose reduction to the radiology staff during the interventional procedure, HandCare (HC). MSD was assessed during each intervention using EBT2 gafchromic films positioned on patient skin. Lesion size, position, total fluoroscopy time, and patient-effective diameter were registered for each patient. Dose rates were also estimated at the surface of a normal-size anthropomorphic thorax phantom using a 10 cm pencil ionization chamber placed at every 30°, for a full rotation, with and without HC. Measured MSD was compared with MSD values estimated from the phantom measurements and with the cumulative CTDIvol of the procedure. Results: The median measured MSD was 141 mGy (range 38–410 mGy) while the median cumulative CTDIvol was 72 mGy (range 24–262 mGy). The ratio between the MSD estimated from phantom measurements and the measured MSD was 0.87 (range 0.12–4.1) on average. In 72% of cases the estimated MSD underestimated the measured MSD, while in 28% of the cases it overestimated it. The same trend was observed for the ratio of cumulative CTDIvol and measured MSD. No trend was observed as a function of patient size. Conclusions: On average, estimated MSD from dose rate measurements on phantom as well as from CTDIvol of patient examinations underestimates the measured value of MSD. This can be attributed to deviations of the patient's body habitus from the standard phantom size and to patient positioning in the gantry during the procedure.

  20. Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies

    International Nuclear Information System (INIS)

    Zanca, F.; Jacobs, A.; Crijns, W.; De Wever, W.

    2014-01-01

    Purpose: To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. Methods: Data from 50 patients with lung lesions who underwent a CT fluoroscopy-guided biopsy were collected. The CT protocol consisted of a low-kilovoltage (80 kV) protocol used in combination with an algorithm for dose reduction to the radiology staff during the interventional procedure, HandCare (HC). MSD was assessed during each intervention using EBT2 gafchromic films positioned on patient skin. Lesion size, position, total fluoroscopy time, and patient-effective diameter were registered for each patient. Dose rates were also estimated at the surface of a normal-size anthropomorphic thorax phantom using a 10 cm pencil ionization chamber placed at every 30°, for a full rotation, with and without HC. Measured MSD was compared with MSD values estimated from the phantom measurements and with the cumulative CTDIvol of the procedure. Results: The median measured MSD was 141 mGy (range 38–410 mGy) while the median cumulative CTDIvol was 72 mGy (range 24–262 mGy). The ratio between the MSD estimated from phantom measurements and the measured MSD was 0.87 (range 0.12–4.1) on average. In 72% of cases the estimated MSD underestimated the measured MSD, while in 28% of the cases it overestimated it. The same trend was observed for the ratio of cumulative CTDIvol and measured MSD. No trend was observed as a function of patient size. Conclusions: On average, estimated MSD from dose rate measurements on phantom as well as from CTDIvol of patient examinations underestimates the measured value of MSD. This can be attributed to deviations of the patient's body habitus from the standard phantom size and to patient positioning in the gantry during the procedure

  1. Dataset for Phase I randomized clinical trial for safety and tolerability of GET 73 in single and repeated ascending doses including preliminary pharmacokinetic parameters

    Directory of Open Access Journals (Sweden)

    Carolina L. Haass-Koffler

    2017-12-01

    Full Text Available The data in this article outline the methods used for the administration of GET 73 in the first time-in-human manuscript entitled “Phase I randomized clinical trial for the safety, tolerability and preliminary pharmacokinetics of the mGluR5 negative allosteric modulator GET 73 following single and repeated doses in healthy male volunteers” (Haass-Koffler et al., 2017 [1]. Data sets are provided in two different manners. The first series of tables provided includes procedural information about the experiments conducted. The next series of tables provided includes Pharmacokinetic (PK parameters for GET 73 and its main metabolite MET 2. This set of data is comprised by two experiments: Experiment 1 references a single ascending dose administration of GET 73 and Experiment 2 references a repeated ascending dose administration of GET 73. Keywords: Glutamate receptor subtype 5 (mGlu5, Allosteric modulator, GET 73, Safety, Tolerability

  2. 77 FR 3617 - Etoxazole; Pesticide Tolerances

    Science.gov (United States)

    2012-01-25

    ... similar doses, indicating that systemic effects (mainly liver effects) occur at similar dose levels... chromatography/mass selective detection (GC/MSD) methods) are available to enforce the tolerance expression. The...

  3. Haloperidol Disrupts Opioid-Antinociceptive Tolerance and Physical Dependence

    Science.gov (United States)

    Yang, Cheng; Chen, Yan; Tang, Lei

    2011-01-01

    Previous studies from our laboratory and others have implicated a critical role of Ca2+/calmodulin-dependent protein kinase II (CaMKII) in opioid tolerance and dependence. Translational research targeting the CaMKII pathway is challenging, if not impossible, because of a lack of selective inhibitors. We discovered in a preliminary study that haloperidol, a butyrophenone antipsychotic drug, inhibited CaMKII, which led us to hypothesize that haloperidol can attenuate opioid tolerance and dependence by inhibiting CaMKII. The hypothesis was tested in two rodent models of opioid tolerance and dependence. Pretreatment with haloperidol (0.2–1.0 mg/kg i.p.) prevented the development of morphine tolerance and dependence in a dose-dependent manner. Short-term treatment with haloperidol (0.06–0.60 mg/kg i.p.) dose-dependently reversed the established morphine-antinociceptive tolerance and physical dependence. Correlating with behavioral effects, pretreatment or short-term treatment with haloperidol dose-dependently inhibited morphine-induced up-regulation of supraspinal and spinal CaMKIIα activity. Moreover, haloperidol given orally was also effective in attenuating morphine-induced CaMKIIα activity, antinociceptive tolerance, and physical dependence. Taken together, these data suggest that haloperidol attenuates opioid tolerance and dependence by suppressing CaMKII activity. Because haloperidol is a clinically used drug that can be taken orally, we propose that the drug may be of use in attenuating opioid tolerance and dependence. PMID:21436292

  4. Amino acid tolerance test using L-β-phenylalanine-125I

    International Nuclear Information System (INIS)

    Hafiez, A.A.; Megahed, Y.M.; Ismail, A.A.; Abdel-Wahab, M.F.; Khater, R.A.

    1978-01-01

    An amino acid tolerance test is described. L-β-phenylalanine- 125 I was used as representative of L-amino acids. The change in radioactivity of the blood after giving a test dose of tagged L-β-phenylalanine was also investigated. L-β-phenylalanine- 125 I tolerance curves were found to be irreproducible when the test dose was given without a carrier. The addition of 2.5 g untagged phenylalanine as a carrier to the test dose allowed a reproducible and precise type of tolerance curves. Metformin in a dose of 0.5 g t.d.s. for three days induced an inhibitory effect on amino acid absorption in normal persons. (author)

  5. Phase I trial of hydroxychloroquine with dose-intense temozolomide in patients with advanced solid tumors and melanoma.

    Science.gov (United States)

    Rangwala, Reshma; Leone, Robert; Chang, Yunyoung C; Fecher, Leslie A; Schuchter, Lynn M; Kramer, Amy; Tan, Kay-See; Heitjan, Daniel F; Rodgers, Glenda; Gallagher, Maryann; Piao, Shengfu; Troxel, Andrea B; Evans, Tracey L; DeMichele, Angela M; Nathanson, Katherine L; O'Dwyer, Peter J; Kaiser, Jonathon; Pontiggia, Laura; Davis, Lisa E; Amaravadi, Ravi K

    2014-08-01

    Blocking autophagy with hydroxychloroquine (HCQ) augments cell death associated with alkylating chemotherapy in preclinical models. This phase I study evaluated the maximum tolerated dose (MTD), safety, preliminary activity, pharmacokinetics, and pharmacodynamics of HCQ in combination with dose-intense temozolomide (TMZ) in patients with advanced solid malignancies. Forty patients (73% metastatic melanoma) were treated with oral HCQ 200 to 1200 mg daily with dose-intense oral TMZ 150 mg/m (2) daily for 7/14 d. This combination was well tolerated with no recurrent dose-limiting toxicities observed. An MTD was not reached for HCQ and the recommended phase II dose was HCQ 600 mg twice daily combined with dose-intense TMZ. Common toxicities included grade 2 fatigue (55%), anorexia (28%), nausea (48%), constipation (20%), and diarrhea (20%). Partial responses and stable disease were observed in 3/22 (14%) and 6/22 (27%) patients with metastatic melanoma. In the final dose cohort 2/6 patients with refractory BRAF wild-type melanoma had a near complete response, and prolonged stable disease, respectively. A significant accumulation in autophagic vacuoles (AV) in peripheral blood mononuclear cells was observed in response to combined therapy. Population pharmacokinetics (PK) modeling, individual PK simulations, and PK-pharmacodynamics (PD) analysis identified a threshold HCQ peak concentration that predicts therapy-associated AV accumulation. This study indicates that the combination of high-dose HCQ and dose-intense TMZ is safe and tolerable, and is associated with autophagy modulation in patients. Prolonged stable disease and responses suggest antitumor activity in melanoma patients, warranting further studies of this combination, or combinations of more potent autophagy inhibitors and chemotherapy in melanoma.

  6. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  7. [Fixed-dose combination fluticasone propionate/formoterol for the treatment of asthma: a review of its pharmacology, efficacy and tolerability].

    Science.gov (United States)

    Quintano Jiménez, J A; Ginel Mendoza, L; Entrenas Costa, L M; Polo García, J

    2016-02-01

    The fixed-dose combination fluticasone propionate/formoterol (FPF) is a novel combination of a widely known and used inhaled glucocorticoid (IGC) and a long-acting β2-adrenergic agonist (LABA), available for the first time in a single device. This fixed-dose combination of FPF has a demonstrated efficacy and safety profile in clinical trials compared with its individual components and other fixed-dose combinations of IGC/LABA and is indicated for the treatment of persistent asthma in adults and adolescents. FPF is available in a wide range of doses that can adequately cover the therapeutic steps recommended by treatment guidelines, constituting a fixed-dose combination of GCI/LABA that is effective, rapid, well tolerated and with a reasonable acquisition cost. Various assessment agencies of the Spanish Autonomous Communities consider this combination to be an appropriate alternative therapy for asthma in the primary care setting. Copyright © 2016 Elsevier España, S.L.U. y Sociedad Española de Medicina Rural y Generalista (SEMERGEN). All rights reserved.

  8. Single- and Multiple-Dose Study To Determine the Safety, Tolerability, Pharmacokinetics, and Food Effect of Oral MRX-I versus Linezolid in Healthy Adult Subjects.

    Science.gov (United States)

    Eckburg, Paul B; Ge, Yigong; Hafkin, Barry

    2017-04-01

    A multipart phase 1 study was conducted to determine the safety, tolerability, pharmacokinetics, and food effect of the novel oral oxazolidinone, MRX-I, in healthy adults, as well as the tolerability of longer-term exposure of both oral MRX-I and linezolid. Thirty subjects in part 1 received single ascending doses of MRX-I or placebo under fasting or fed condition in a double-blind crossover design. Twelve subjects in part 2 received MRX-I at 800 mg every 12 h (q12h) for 14 days in a double-blind, placebo-controlled design. In part 3, 24 subjects were randomized to receive 28 days of MRX-I at 800 mg q12h or oral linezolid at 600 mg q12h for 28 days in a double-blind, double-dummy design. Oral MRX-I was associated with a greater bioavailability and exposure when administered with food, and minimal accumulation of MRX-I occurred after multiple-dose administration. Oral MRX-I was well tolerated at single doses of up to 1,200 and 800 mg q12h for up to 28 days; all adverse events were mild to moderate in severity, and there was no drug discontinuation due to adverse events. These data support further clinical development of oral MRX-I in the treatment of resistant Gram-positive bacterial infections. Copyright © 2017 American Society for Microbiology.

  9. Tolerance and efficacy of a low dose of the calcimimetic agent cinacalcet in controlling moderate to severe secondary hyperparathyroidism in hemodialysis patients.

    Science.gov (United States)

    Bashir, Salah O; Omer, Hayder A; Aamer, Mahmoud A; Somialy, Rashid; Morsy, Mohamed D

    2015-11-01

    Secondary hyperparathyroidism is almost a constant feature in chronic kidney disease (CKD) patients maintained on hemodialysis (HD). Calcimimetic agents appear to offer an alternative to surgery in controlling secondary hyperparathyroidism in these patients. Recent studies provide conflicting data on the benefits, efficacy and tolerance of cinacalcet as first-line therapy for the treatment of secondary hyperparathyroidism in CKD. This study was designed to investigate the efficacy and tolerance of a low dose of the calcimimetic agent cinacalcet in patients on long-term HD having moderate to severe secondary hyperparathyroidism. Twenty five adult male patients on HD for more than three years were included in the study. All had moderate to severe secondary hyperparathyroidism with serum intact parathyroid hormone (iPTH) >50 pmol/L, resistant to conventional treatment. We used the targets of Chronic Kidney Disease: Outcomes Quality Initiative (K/DOQI) clinical guidelines as optimal target of serum iPTH, calcium and phosphate. Patients were administered cinacalcet as a single oral daily dose of 30 mg and were followed-up for six months. Cinacalcet treatment for six months resulted in a significant reduction in the serum phosphate and iPTH levels while the serum calcium levels remained unchanged. Thirty-six percent of the patients attained the recommended serum iPTH levels, 40% achieved significant reduction of the serum iPTH levels and 24% showed no favorable response. Only one patient dropped out because of severe gastrointestinal symptoms. Our results suggest that treatment of CKD patients, having moderate to severe secondary hyperparathyroidism, with low-dose cinacalcet is effective and well tolerated.

  10. Pesticide tolerant and phosphorus solubilizing Pseudomonas sp. strain SGRAJ09 isolated from pesticides treated Achillea clavennae rhizosphere soil.

    Science.gov (United States)

    Rajasankar, R; Manju Gayathry, G; Sathiavelu, A; Ramalingam, C; Saravanan, V S

    2013-05-01

    In this study, an attempt was made to identify an effective phosphate solubilizing bacteria from pesticide polluted field soil. Based on the formation of solubilization halo on Pikovskaya's agar, six isolates were selected and screened for pesticide tolerance and phosphate (P) solubilization ability through liquid assay. The results showed that only one strain (SGRAJ09) obtained from Achillea clavennae was found to tolerate maximum level of the pesticides tested and it was phylogenetically identified as Pseudomonas sp. It possessed a wide range of pesticide tolerance, ranging from 117 μg mL(-1) for alphamethrin to 2,600 μg mL(-1) for endosulfan. The available P concentrations increased with the maximum and double the maximum dose of monocrotophos and imidacloprid, respectively. On subjected to FT-IR and HPLC analysis, the presence of organic acids functional group in the culture broth and the production of gluconic acid as dominant acid aiding the P solubilization were identified. On comparison with control broth, monocrotophos and imidacloprid added culture broth showed quantitatively high organic acids production. In addition to gluconic acid production, citric and acetic acids were also observed in the pesticide amended broth. Furthermore, the Pseudomonas sp. strain SGRAJ09 possessed all the plant growth promoting traits tested. In presence of monocrotophos and imidacloprid, its plant growth promoting activities were lower than that of the pesticides unamended treatment.

  11. Tolerance to and cross tolerance between ethanol and nicotine.

    Science.gov (United States)

    Collins, A C; Burch, J B; de Fiebre, C M; Marks, M J

    1988-02-01

    Female DBA mice were subjected to one of four treatments: ethanol-containing or control diets, nicotine (0.2, 1.0, 5.0 mg/kg/hr) infusion or saline infusion. After removal from the liquid diets or cessation of infusion, the animals were challenged with an acute dose of ethanol or nicotine. Chronic ethanol-fed mice were tolerant to the effects of ethanol on body temperature and open field activity and were cross tolerant to the effects of nicotine on body temperature and heart rate. Nicotine infused animals were tolerant to the effects of nicotine on body temperature and rotarod performance and were cross tolerant to the effects of ethanol on body temperature. Ethanol-induced sleep time was decreased in chronic ethanol- but not chronic nicotine-treated mice. Chronic drug treatment did not alter the elimination rate of either drug. Chronic ethanol treatment did not alter the number or affinity of brain nicotinic receptors whereas chronic nicotine treatment elicited an increase in the number of [3H]-nicotine binding sites. Tolerance and cross tolerance between ethanol and nicotine is discussed in terms of potential effects on desensitization of brain nicotinic receptors.

  12. Biphasic Effect of Curcumin on Morphine Tolerance: A Preliminary Evidence from Cytokine/Chemokine Protein Array Analysis

    Directory of Open Access Journals (Sweden)

    Jui-An Lin

    2011-01-01

    Full Text Available The aim of this study was to evaluate the effect of curcumin on morphine tolerance and the corresponding cytokine/chemokine changes. Male ICR mice were made tolerant to morphine by daily subcutaneous injection for 7 days. Intraperitoneal injections of vehicle, low-dose or high-dose curcumin were administered 15 min after morphine injection, either acutely or chronically for 7 days to test the effect of curcumin on morphine-induced antinociception and development of morphine tolerance. On day 8, cumulative dose-response curves were generated and the 50% of maximal analgesic dose values were calculated and compared among groups. Corresponding set of mice were used for analyzing the cytokine responses by antibody-based cytokine protein array. Acute, high-dose curcumin enhanced morphine-induced antinociception. While morphine tolerance was attenuated by administration of low-dose curcumin following morphine injections for 7 days, it was aggravated by chronic high-dose curcumin following morphine injection, suggesting a biphasic effect of curcumin on morphine-induced tolerance. Of the 96 cytokine/chemokines analyzed by mouse cytokine protein array, 14 cytokines exhibited significant changes after the different 7-day treatments. Mechanisms for the modulatory effects of low-dose and high-dose curcumin on morphine tolerance were discussed. Even though curcumin itself is a neuroprotectant and low doses of the compound serve to attenuate morphine tolerance, high-doses of curcumin might cause neurotoxicity and aggravate morphine tolerance by inhibiting the expression of antiapoptotic cytokines and neuroprotective factors. Our results indicate that the effect of curcumin on morphine tolerance may be biphasic, and therefore curcumin should be used cautiously.

  13. Safety, tolerability, and pharmacokinetics of single oral doses of tofacitinib, a Janus kinase inhibitor, in healthy volunteers.

    Science.gov (United States)

    Krishnaswami, Sriram; Boy, Mary; Chow, Vincent; Chan, Gary

    2015-03-01

    Tofacitinib is an oral Janus kinase inhibitor. This randomized, double-blind, parallel-group, placebo-controlled study was the first evaluation of tofacitinib in humans. The objectives were to characterize the safety and tolerability, pharmacokinetics (PK), and pharmacodynamics of escalating single tofacitinib doses in healthy subjects. Tofacitinib (0.1, 0.3, 1, 3, 10, 30, 60, and 100 mg) or placebo was administered as oral powder for constitution. For each dose, 7-9 subjects were randomized to tofacitinib and 3-5 subjects to placebo. Ninety-five males and females (age range 19-45) completed the study. Forty-nine treatment-emergent all-causality adverse events (AEs) were observed; nausea and headache were the most frequently reported. Tofacitinib PK was characterized by rapid absorption (time to peak serum concentration [Tmax ] 0.5-1 hour), rapid elimination (mean terminal half-lives 2.3-3.1 hours), and dose-proportional systemic exposures (peak serum concentration [Cmax ] and area under the serum concentration-time curve from time zero to infinity [AUC0-∞ ]). No appreciable correlation was observed between tofacitinib dose and lymphocyte subset counts. Single-dose tofacitinib up to 100 mg in healthy subjects had a safety profile of mostly mild AEs, and no deaths, serious AEs, severe AEs or discontinuations due to AEs. © 2014, The American College of Clinical Pharmacology.

  14. Stereotactic Body Radiation Therapy Boost After Concurrent Chemoradiation for Locally Advanced Non-Small Cell Lung Cancer: A Phase 1 Dose Escalation Study

    Energy Technology Data Exchange (ETDEWEB)

    Hepel, Jaroslaw T., E-mail: jhepel@lifespan.org [Department of Radiation Oncology, Rhode Island Hospital, Brown University, Providence, Rhode Island (United States); Department of Radiation Oncology, Tufts Medical Center, Tufts University, Boston, Massachusetts (United States); Leonard, Kara Lynne [Department of Radiation Oncology, Rhode Island Hospital, Brown University, Providence, Rhode Island (United States); Department of Radiation Oncology, Tufts Medical Center, Tufts University, Boston, Massachusetts (United States); Safran, Howard [Division of Medical Oncology, Rhode Island Hospital, Brown University, Providence, Rhode Island (United States); Division of Medical Oncology, Miriam Hospital, Brown University, Providence, Rhode Island (United States); Ng, Thomas [Division of Thoracic Surgery, Rhode Island Hospital, Brown University, Providence, Rhode Island (United States); Taber, Angela [Division of Medical Oncology, Miriam Hospital, Brown University, Providence, Rhode Island (United States); Khurshid, Humera; Birnbaum, Ariel [Division of Medical Oncology, Rhode Island Hospital, Brown University, Providence, Rhode Island (United States); Wazer, David E.; DiPetrillo, Thomas [Department of Radiation Oncology, Rhode Island Hospital, Brown University, Providence, Rhode Island (United States); Department of Radiation Oncology, Tufts Medical Center, Tufts University, Boston, Massachusetts (United States)

    2016-12-01

    Purpose: Stereotactic body radiation therapy (SBRT) boost to primary and nodal disease after chemoradiation has potential to improve outcomes for advanced non-small cell lung cancer (NSCLC). A dose escalation study was initiated to evaluate the maximum tolerated dose (MTD). Methods and Materials: Eligible patients received chemoradiation to a dose of 50.4 Gy in 28 fractions and had primary and nodal volumes appropriate for SBRT boost (<120 cc and <60 cc, respectively). SBRT was delivered in 2 fractions after chemoradiation. Dose was escalated from 16 to 28 Gy in 2 Gy/fraction increments, resulting in 4 dose cohorts. MTD was defined when ≥2 of 6 patients per cohort experienced any treatment-related grade 3 to 5 toxicity within 4 weeks of treatment or the maximum dose was reached. Late toxicity, disease control, and survival were also evaluated. Results: Twelve patients (3 per dose level) underwent treatment. All treatment plans met predetermined dose-volume constraints. The mean age was 64 years. Most patients had stage III disease (92%) and were medically inoperable (92%). The maximum dose level was reached with no grade 3 to 5 acute toxicities. At a median follow-up time of 16 months, 1-year local-regional control (LRC) was 78%. LRC was 50% at <24 Gy and 100% at ≥24 Gy (P=.02). Overall survival at 1 year was 67%. Late toxicity (grade 3-5) was seen in only 1 patient who experienced fatal bronchopulmonary hemorrhage (grade 5). There were no predetermined dose constraints for the proximal bronchial-vascular tree (PBV) in this study. This patient's 4-cc PBV dose was substantially higher than that received by other patients in all 4 cohorts and was associated with the toxicity observed: 20.3 Gy (P<.05) and 73.5 Gy (P=.07) for SBRT boost and total treatment, respectively. Conclusions: SBRT boost to both primary and nodal disease after chemoradiation is feasible and well tolerated. Local control rates are encouraging, especially at doses ≥24

  15. Validation of calculated tissue maximum ratio obtained from measured percentage depth dose (PPD) data for high energy photon beam ( 6 MV and 15 MV)

    International Nuclear Information System (INIS)

    Osei, J.E.

    2014-07-01

    During external beam radiotherapy treatments, high doses are delivered to the cancerous cell. Accuracy and precision of dose delivery are primary requirements for effective and efficiency in treatment. This leads to the consideration of treatment parameters such as percentage depth dose (PDD), tissue air ratio (TAR) and tissue phantom ratio (TPR), which show the dose distribution in the patient. Nevertheless, tissue air ratio (TAR) for treatment time calculation, calls for the need to measure in-air-dose rate. For lower energies, measurement is not a problem but for higher energies, in-air measurement is not attainable due to the large build-up material required for the measurement. Tissue maximum ratio (TMR) is the quantity required to replace tissue air ratio (TAR) for high energy photon beam. It is known that tissue maximum ratio (TMR) is an important dosimetric function in radiotherapy treatment. As the calculation methods used to determine tissue maximum ratio (TMR) from percentage depth dose (PDD) were derived by considering the differences between TMR and PDD such as geometry and field size, where phantom scatter or peak scatter factors are used to correct dosimetric variation due to field size difference. The purpose of this study is to examine the accuracy of calculated tissue maximum ratio (TMR) data with measured TMR values for 6 MV and 15 MV photon beam at Sweden Ghana Medical Centre. With the help of the Blue motorize water phantom and the Omni pro-Accept software, Pdd values from which TMRs are calculated were measured at 100 cm source-to-surface distance (SSD) for various square field sizes from 5x5 cm to 40x40 cm and depth of 1.5 cm to 25 cm for 6 MV and 15 MV x-ray beam. With the same field sizes, depths and energies, the TMR values were measured. The validity of the calculated data was determined by making a comparison with values measured experimentally at some selected field sizes and depths. The results show that; the reference depth of maximum

  16. Pharmacokinetics and safety of fentanyl sublingual spray and fentanyl citrate intravenous: a single ascending dose study in opioid-naïve healthy volunteers.

    Science.gov (United States)

    Rauck, Richard; Oh, D Alexander; Parikh, Neha; Koch, Christian; Singla, Neil; Yu, Jin; Nalamachu, Srinivas; Vetticaden, Santosh

    2017-11-01

    Fentanyl sublingual spray offers rapid pain relief in opioid-tolerant cancer patients, and may be useful in acute or post-operative pain. Both opioid-naïve and non-tolerant patients are likely to receive opioids in these settings. Understanding the relationship between systemic exposure of fentanyl sublingual spray and effects on respiratory function in opioid-naïve or non-tolerant populations is important to ensure patient safety. This study evaluated single-dose fentanyl sublingual spray in opioid-naïve participants. Participants were randomized to receive single-dose fentanyl sublingual spray (100, 200, 400, 600, 800 mcg) or fentanyl citrate IV in one of five cohorts. Dosing occurred following a 10-h fast, with fasting continuing for 4 h post-dose. Dose proportionality was assessed using analysis of variance and linear regression techniques. PK assessments and safety monitoring were performed through 24 h post-dose. Safety assessments, including adverse event (AE) monitoring, occurred from dosing through Day 7. Fifty participants (19-53 years) received fentanyl sublingual spray or fentanyl citrate IV. Mean maximum plasma concentrations were reached between 0.27-0.60 h post-dose for fentanyl sublingual spray. Peak (C max ) and total (AUC 0- t , AUC 0-∞ ) fentanyl exposures increased in a linear, but more than dose-proportional manner, with higher doses. The most common AEs were somnolence, nausea, and vomiting. All AEs were mild or moderate in severity. Doses at 400, 600, and 800 mcg were associated with nausea and vomiting, requiring pharmacologic intervention. Hypoxia episodes requiring nasal cannula oxygenation were observed with 600mcg and 800mcg doses. Overall, single-dose fentanyl sublingual spray (100-800 mcg) was generally well tolerated, with greater incidences of AEs (e.g. nausea, vomiting, hypoxia) at higher doses. Doses up to 200 mcg may be safely administered to healthy opioid-naïve individuals with routine monitoring; doses

  17. [Comparative study on the tolerance and efficacy of high doses of metoclopramide and clebopride in vomiting induced by cisplatin].

    Science.gov (United States)

    Martín, M; Díaz-Rubio, E

    1989-06-10

    Forty-one patients treated with cisplatin (100-120 mg/m2), alone or associated with vindesine (3 mg/m2), were included in a randomized crossover pilot study which compared 3 different doses of intravenous clebopride with intravenous metoclopramide. The patients were randomly assigned to receive clebopride in the first chemotherapy course in one of the three dose levels used (0.5 mg/kg, 21 patients; 0.75 mg/kg, 11 patients; 1 mg/kg, 10 patients) or metoclopramide (10 mg/kg). In the second course of the same chemotherapy the patients received the alternative antiemetic, and thus each patient was his own control. The total dose of both antiemetic drugs was infused in 5 intravenous fractions given every 2 hours. The antiemetic activity of clebopride was moderately lower to that of metoclopramide with the first two tested doses (overall doses of 0.5 and 0.75 mg/kg) and similar with the last dose (1 mg/kg). Clebopride was reasonably well tolerated at the used dosages, inducing sedation in 20% of cases (versus 24% with metoclopramide) and diarrhea in 37% (versus 20% with metoclopramide). Extrapyramidal reactions developed in 17% of the courses which included metoclopramide and in none including clebopride. This difference was statistically significant.

  18. [MAXIMUM SINGLE DOSE OF COLLOIDAL SILVER NEGATIVELY AFFECTS ERYTHROPOIESIS IN VITRO].

    Science.gov (United States)

    Tishevskayal, N V; Zakharovl, Y M; Bolotovl, A A; Arkhipenko, Yu V; Sazontova, T G

    2015-01-01

    Erythroblastic islets (EI) of rat bone marrow were cultured for 24 h in the presence of silver nanoparticles (1.07 · 10(-4) mg/ml; 1.07 · 10(-3) mg/ml; and 1.07 · 10(-2) mg/mL). The colloidal silver at 1.07 · 10(-3) mg/ml concentration inhibited the formation of new Elby disrupting contacts of bone marrow macrophages with CFU-E (erythropoiesis de novo) by 65.3% (p Colloidal silver nanoparticles suppressed the reconstruction of erythropoiesis and inhibited the formation of new EI by disrupting contacts of CFU-E and central macrophages with matured erythroidal "crown" (erythropoiesis de repeto). The colloidal silver concentration of 1.07 · 10(-3) mg/ml in the culture medium also reduced the number of self-reconstructing EI by 67.5% (p colloidal silver reduced this value by 93.7% (p Silver nanoparticles retarded maturation of erythroid cells at the stage of oxiphylic normoblast denucleation: 1.07 · 10(-3) mg/ml colloidal silver increased the number of mature El by 53% (p colloidal silver in concentration equivalent to the maximum single dose is related to the effect of silver nanoparticles rather than glycerol present in the colloidal suspension.

  19. Feasibility of extreme dose escalation for glioblastoma multiforme using 4π radiotherapy

    International Nuclear Information System (INIS)

    Nguyen, Dan; Rwigema, Jean-Claude M; Yu, Victoria Y; Kaprealian, Tania; Kupelian, Patrick; Selch, Michael; Lee, Percy; Low, Daniel A; Sheng, Ke

    2014-01-01

    Glioblastoma multiforme (GBM) frequently recurs at the same location after radiotherapy. Further dose escalation using conventional methods is limited by normal tissue tolerance. 4π non-coplanar radiotherapy has recently emerged as a new potential method to deliver highly conformal radiation dose using the C-arm linacs. We aim to study the feasibility of very substantial GBM dose escalation while maintaining normal tissue tolerance using 4π. 11 GBM patients previously treated with volumetric modulated arc therapy (VMAT/RapidArc) on the NovalisTx™ platform to a prescription dose of either 59.4 Gy or 60 Gy were included. All patients were replanned with 30 non-coplanar beams using a 4π radiotherapy platform, which inverse optimizes both beam angles and fluence maps. Four different prescriptions were used including original prescription dose and PTV (4πPTV PD ), 100 Gy to the PTV and GTV (4πPTV 100Gy ), 100 Gy to the GTV only while maintaining prescription dose to the rest of the PTV (4πGTV 100Gy ), and a 5 mm margin expansion plan (4πPTV PD+5mm ). OARs included in the study are the normal brain (brain – PTV), brainstem, chiasm, spinal cord, eyes, lenses, optical nerves, and cochleae. The 4π plans resulted in superior dose gradient indices, as indicated by >20% reduction in the R50, compared to the clinical plans. Among all of the 4π cases, when compared to the clinical plans, the maximum and mean doses were significantly reduced (p < 0.05) by a range of 47.01-98.82% and 51.87-99.47%, respectively, or unchanged (p > 0.05) for all of the non-brain OARs. Both the 4πPTV PD and 4π GTV 100GY plans reduced the mean normal brain mean doses. 4π non-coplanar radiotherapy substantially increases the dose gradient outside of the PTV and better spares critical organs. Dose escalation to 100 Gy to the GTV or additional margin expansion while meeting clinical critical organ dose constraints is feasible. 100 Gy to the PTV result in higher normal brain doses but may

  20. Commercialization of radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Choi, Young Soo; Kim, Sun Ku; Lee, Jong Min; Cha, Bung Hun; Lee, Nam Ho; Byun, Eiy Gyo; Yoo, Seun Wook; Choi, Bum Ki; Yoon, Sung Up; Kim, Hyun Gun; Sin, Jeong Hun; So, Suk Il

    1999-12-01

    In this project, radiation tolerant camera which tolerates 10{sup 6} - 10{sup 8} rad total dose is developed. In order to develop radiation tolerant camera, radiation effect of camera components was examined and evaluated, and camera configuration was studied. By the result of evaluation, the components were decided and design was performed. Vidicon tube was selected to use by image sensor and non-browning optics and camera driving circuit were applied. The controller needed for CCTV camera system, lens, light, pan/tilt controller, was designed by the concept of remote control. And two type of radiation tolerant camera were fabricated consider to use in underwater environment or normal environment. (author)

  1. Commercialization of radiation tolerant camera

    International Nuclear Information System (INIS)

    Lee, Yong Bum; Choi, Young Soo; Kim, Sun Ku; Lee, Jong Min; Cha, Bung Hun; Lee, Nam Ho; Byun, Eiy Gyo; Yoo, Seun Wook; Choi, Bum Ki; Yoon, Sung Up; Kim, Hyun Gun; Sin, Jeong Hun; So, Suk Il

    1999-12-01

    In this project, radiation tolerant camera which tolerates 10 6 - 10 8 rad total dose is developed. In order to develop radiation tolerant camera, radiation effect of camera components was examined and evaluated, and camera configuration was studied. By the result of evaluation, the components were decided and design was performed. Vidicon tube was selected to use by image sensor and non-browning optics and camera driving circuit were applied. The controller needed for CCTV camera system, lens, light, pan/tilt controller, was designed by the concept of remote control. And two type of radiation tolerant camera were fabricated consider to use in underwater environment or normal environment. (author)

  2. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  3. Dose escalation of cisplatin with 5-fluorouracil in concurrent chemoradiotherapy for esophageal carcinoma

    International Nuclear Information System (INIS)

    Lin Qiang; Gao Xianshu; Qiao Xueying; Zhou Zhiguo; Zhang Jun; Yang Xiangran; Wan Xin

    2006-01-01

    Objective: To define the maximum-tolerated dose (MTD) and observe the side effect of escalating cisplatin with 5-fluorouracil in concurrent chemoradiotherapy for esophageal carcinoma in Chinese, with toxicity studied. Methods: Previously untreated fifteen Chinese patients suffering from esophageal carcinoma received conventional fractionation radiotherapy, with 5 daily fractions of 2.0 Gy per week. The total radiation dose was 60 Gy. Concurrent chemotherapy dose escalation was given by the relatively safe and kidney-sparing modified Fibonacci sequence. The starting dose was cisplatin 37.5 mg/m 2 D1 and 5-fluorouracil 500 mg/m 2 D1-5, respectively. This regimen was repeated 4 times every 28 days. Escalation dose was cisplatin 7.5 mg/m 2 and 5- fluorouracil 100 mg/m 2 . Every. cohort contained at least 3 patients. If no dose-limiting toxicity(DLT) was observed, the next dose level was opened for entry. These courses were repeated until DLT appeared. MTD was declared as one dose level below which DLT appeared. Results: DLT was defined as grade 3 radiation-induced esophagitis at the level of cisplatin 60 mg/m2, 5-fluorouracil 700 mg/m 2 . MTD was defined as cisplatin 52.5 mg/m 2 , 5- fiuorouracil 700 mg/m 2 . The major side effect were radiation-induced esophagitis, leucopenia, nausea, vomiting and anorexia. Conclusion: Maximun tolerated dose of cisplatin with 5-fiuorouracil in concurrent ehemoradiotherapy in the Chinese people with esophageal carcinoma were eisplatin 52.5 mg/m2 D1,5-fluorouracil 700 mg/m 2 D1-5, repeated 4 times every 28 days. (authors)

  4. EPR spectrum deconvolution and dose assessment of fossil tooth enamel using maximum likelihood common factor analysis

    International Nuclear Information System (INIS)

    Vanhaelewyn, G.; Callens, F.; Gruen, R.

    2000-01-01

    In order to determine the components which give rise to the EPR spectrum around g = 2 we have applied Maximum Likelihood Common Factor Analysis (MLCFA) on the EPR spectra of enamel sample 1126 which has previously been analysed by continuous wave and pulsed EPR as well as EPR microscopy. MLCFA yielded agreeing results on three sets of X-band spectra and the following components were identified: an orthorhombic component attributed to CO - 2 , an axial component CO 3- 3 , as well as four isotropic components, three of which could be attributed to SO - 2 , a tumbling CO - 2 and a central line of a dimethyl radical. The X-band results were confirmed by analysis of Q-band spectra where three additional isotropic lines were found, however, these three components could not be attributed to known radicals. The orthorhombic component was used to establish dose response curves for the assessment of the past radiation dose, D E . The results appear to be more reliable than those based on conventional peak-to-peak EPR intensity measurements or simple Gaussian deconvolution methods

  5. Tolerance of cut flowers to gamma-radiation

    International Nuclear Information System (INIS)

    Kikuchi, O.K.; Wiendl, F.M.; Arthur, V.

    1999-01-01

    Cut flowers were gamma-irradiated with doses of 0, 200, 400, 600, and 1000 Gy. Dianthuscaryophyllus (Caryophyllaceae), Gypsophila paniculata (Caryophyllaceae), Freesia sp (Iridaceae), Limonium sinuatum Mill. (Plumbaginaceae), L. latifolium Kuntze (Plumbaginaceae), Narcissus tazetta L. (Amaryllidaceae), Helichrysum bracteatum Andr. (Compositae) and Rhodanthe manglesii Lindl (Compositae) were tolerant up to 1000 Gy, without visible negative changes after irradiation and during the vase-life. Callistephus chinensis (Compositae) and Lilium longiflorum Thunb. (Liliaceae) were moderately tolerant, but were modified by high doses. Anthurium sp (Araceae), Strelitzia sp (Musaceae), Matthiola incana R. Br. (Cruciferae), Aechmea distichanta (Bromeliaceae), Consolida ajacis Niew (Ranunculaceae), Ranunculus sp (Ranunculaceae), Dendrobium phalenopsis (Orchidaceae) and Gerbera sp (Compositae) were not tolerant to a dose of 200 Gy. The most adequate flowers to be submitted to irradiation treatment for disinfestation purpose were those of the Caryophillaceae family and those which can be used as dried flowers, such as members of the Rhodanthe, Helichrysum and Limmonium genera. (author)

  6. Phase I dose-escalation and pharmacokinetic study (TED 11576) of cabazitaxel in Japanese patients with castration-resistant prostate cancer.

    Science.gov (United States)

    Mukai, Hirofumi; Takahashi, Shunji; Nozawa, Masahiro; Onozawa, Yusuke; Miyazaki, Jun; Ohno, Keiji; Suzuki, Kazuhiro

    2014-04-01

    The purpose of the study is to analyze the pharmacokinetic (PK) profile of cabazitaxel and evaluate its safety and tolerability as a 1-h IV infusion every 3 weeks in Japanese patients with castration-resistant prostate cancer (CRPC). Seventeen patients were treated with cabazitaxel at doses of 20 and 25 mg/m(2) for PK analyses. Dose escalation was performed only in the absence of dose-limiting toxicity (DLT). The maximum tolerated dose (MTD) was the highest dose at which less than 33 % of the patients developed DLT. Cabazitaxel exhibited a triphasic elimination profile with a long terminal half-life of 116 ± 29.0 or 113 ± 28.0 h after IV infusion of 20 or 25 mg/m(2) cabazitaxel, respectively. The major differences in the PK parameters of cabazitaxel and docetaxel were cabazitaxel's fairly high clearance rate, representing approximately half the hepatic flow, and its large volume of distribution at steady-state conditions. No DLT was observed during Cycle 1. Mild-to-moderate hematological adverse events (AEs), including neutropenia, and other AEs typically associated with taxanes were observed; all AEs were manageable. Cabazitaxel at 25 mg/m(2) every 3 weeks was selected as the MTD in Japanese patients. The PK parameters of cabazitaxel in Japanese CRPC patients were comparable with those previously determined in Caucasian subjects. The safety and tolerability of cabazitaxel were also comparable in both ethnic populations.

  7. Production and bromatologic composition of grass-mombaça (Panicum maximum Jacq., submitted to different sources and doses of acidity corrective / Produção e composição bromatológica da forragem do capim-mombaça (Panicum maximum Jacq., submetidos a diferentes fontes e doses de corretivo de acidez

    Directory of Open Access Journals (Sweden)

    Francisco Maximino Fernandes

    2010-04-01

    Full Text Available The experiment was carried in protected (greenhouse atmosphere, in University of Engineering, UNESP of Ilha Solteira-SP, with the objective of evaluating sources (limestone and calcium silicate slag and doses (0,0 – 0,5 – 1,0 – 1,5 – 2,0 times the recommended dose of corrective in the bromatologic composition, tillering and production of dry matter of the grass mombaça (Panicum maximum Jacq.. The lineation was completely randomized design, with four repetitions. It was evaluated the tiller number, the production of dry matter, the gross protein, neutral detergent fiber (NDF and acid detergent fiber (ADF. The corrective influenced the tillering in almost all of the countings. The limestone provided larger production of dry matter in the doses of 1,5 and 2,0 times the recommended dose. The bromatologic composition of the forage was not influenced by the corrective and doses.O experimento foi conduzido em ambiente protegido (estufa, na Faculdade de Engenharia, UNESP de Ilha Solteira, com o objetivo de avaliar fontes (calcário e escória silicatada e doses (0,0 – 0,5 – 1,0 – 1,5 – 2,0 vezes a dose recomendada de corretivos na composição bromatológica, perfilhamento e produção de matéria seca do capim-mombaça (Panicum maximum Jacq.. O delineamento experimental utilizado foi inteiramente casualizado, com quatro repetições. Avaliou-se o número de perfilhos, a produção de matéria seca e os teores de proteína bruta (PB, fibra em detergente neutro (FDN e fibra em detergente ácido (FDA. Os corretivos influenciaram o perfilhamento em quase todas as contagens. O calcário proporcionou maior produção de matéria seca nas doses de 1,5 e 2,0 vezes a dose recomendada. A composição bromatológica da forragem não foi influenciada pelos corretivos e doses utilizadas.

  8. An increased rectal maximum tolerable volume and long anal canal are associated with poor short-term response to biofeedback therapy for patients with anismus with decreased bowel frequency and normal colonic transit time.

    Science.gov (United States)

    Rhee, P L; Choi, M S; Kim, Y H; Son, H J; Kim, J J; Koh, K C; Paik, S W; Rhee, J C; Choi, K W

    2000-10-01

    Biofeedback is an effective therapy for a majority of patients with anismus. However, a significant proportion of patients still failed to respond to biofeedback, and little has been known about the factors that predict response to biofeedback. We evaluated the factors associated with poor response to biofeedback. Biofeedback therapy was offered to 45 patients with anismus with decreased bowel frequency (less than three times per week) and normal colonic transit time. Any differences in demographics, symptoms, and parameters of anorectal physiologic tests were sought between responders (in whom bowel frequency increased up to three times or more per week after biofeedback) and nonresponders (in whom bowel frequency remained less than three times per week). Thirty-one patients (68.9 percent) responded to biofeedback and 14 patients (31.1 percent) did not. Anal canal length was longer in nonresponders than in responders (4.53 +/- 0.5 vs. 4.08 +/- 0.56 cm; P = 0.02), and rectal maximum tolerable volume was larger in nonresponders than in responders. (361 +/- 87 vs. 302 +/- 69 ml; P = 0.02). Anal canal length and rectal maximum tolerable volume showed significant differences between responders and nonresponders on multivariate analysis (P = 0.027 and P = 0.034, respectively). This study showed that a long anal canal and increased rectal maximum tolerable volume are associated with poor short-term response to biofeedback for patients with anismus with decreased bowel frequency and normal colonic transit time.

  9. 40 CFR 180.422 - Tralomethrin; tolerances for residues.

    Science.gov (United States)

    2010-07-01

    ...-handling establishments, including food service, manufacturing, and processing establishments, such as... shall be limited to a maximum of 0.06 percent active ingredient. Contamination of food and food-contact...) PESTICIDE PROGRAMS TOLERANCES AND EXEMPTIONS FOR PESTICIDE CHEMICAL RESIDUES IN FOOD Specific Tolerances...

  10. Dose escalation of the hypoxic cell sensitizer etanidazole combined with ifosfamide, carboplatin, etoposide, and autologous hematopoietic stem cell support.

    Science.gov (United States)

    Elias, A D; Wheeler, C; Ayash, L J; Schwartz, G; Ibrahim, J; Mills, L; McCauley, M; Coleman, N; Warren, D; Schnipper, L; Antman, K H; Teicher, B A; Frei, E

    1998-06-01

    Multiple mechanisms of drug resistance contribute to treatment failure. Although high-dose therapy attempts to overwhelm these defenses pharmacologically, this approach is only successful in a fraction of treated patients. Many drug resistance mechanisms are shared between malignant and normal cells, but the expression of various drug resistance mechanisms associated with hypoxia is largely confined to tumor tissue. Thus, reversal of this mechanism is likely to provide a therapeutic advantage to the host. This study was designed to define the dose-limiting toxicities and maximum tolerated dose of etanidazole when it is given concurrently with high-dose ifosfamide, carboplatin, and etoposide (ICE), with hematopoietic stem cell support. The maximum tolerated doses of high-dose ICE were administered concurrently with dose escalations of etanidazole, a hypoxic cell sensitizer. All agents were given by 96-h continuous i.v. infusion beginning on day -7. Mesna uroprotection was provided. Autologous marrow and cytokine mobilized peripheral blood progenitor cells were reinfused on day 0. Granulocyte colony-stimulating factor was administered following reinfusion until the granulocytes recovered to > 1000/microliter. Fifty-five adults with advanced malignancies were enrolled in cohorts of five to nine patients. Four dose levels of etanidazole between 3 and 5.5 g/m2/day (12, 16, 20, and 22 g/m2 total doses) and two doses of carboplatin (1600 and 1800 mg/m2 total doses) were evaluated. Seven patients died of organ toxicity (13%); two each from veno-occlusive disease of liver and sepsis; and one each from sudden death, renal failure, and refractory thrombocytopenic hemorrhage. Five deaths occurred at the top dose level. One additional patient suffered a witnessed cardiorespiratory arrest from ventricular fibrillation and was resuscitated. Dose-dependent and largely reversible peripheral neuropathy was observed consisting of two syndromes: severe cramping myalgic/neuralgic pain

  11. Attenuation of morphine tolerance and dependence by thymoquinone in mice

    Directory of Open Access Journals (Sweden)

    Hossein Hosseinzadeh

    2016-01-01

    Full Text Available Objectives: Dependence and tolerance are major restricting factors in the clinical use of opioid analgesics. In the present study, the effects of thymoquinone, the major constituent of Nigella sativa seeds, on morphine dependence and tolerance were investigated in mice. Materials and Methods: Male adult NMRI mice were made tolerant and dependent by repeated injections of morphine (50, 50, and 75 mg/kg, i.p. on 9 a.m., 1 p.m., and 5 p.m., respectively during a 3-day administration schedule. The hot-plate test was used to assess tolerance to the analgesic effects of morphine. Naloxone (2 mg/kg, i.p. was injected to precipitate withdrawal syndrome in order to assess the morphine dependence. To evaluate the effects of thymoquinone on tolerance and dependence to morphine, different single or repeated doses of thymoquinone were administered in mice. Rotarod was used to assess the motor coordination. Results: Administration of single or repeated doses of thymoquinone (20 and 40 mg/kg, i.p. significantly decreased the number of jumps in morphine dependent animals. Repeated administration of thymoquinone (20 and 40 mg/kg, for 3 days and also single injection of thymoquinone (40 mg/kg, on the fourth day attenuated tolerance to the analgesic effect of morphine. None of the thymoquinone doses (10, 20, and 40 mg/kg produced any antinociceptive effects on their own. Motor coordination of animals was impaired by the high dose of thymoquinone (40 mg/kg. Conclusion: Based on these results, it can be concluded that thymoquinone prevents the development of tolerance and dependence to morphine.

  12. HDR- and LDR-interstitial irradiation (IRT) in rat spinal cord: the effect of decreasing the dose rate and the impact of a rapid dose fall off over the spinal cord

    International Nuclear Information System (INIS)

    Pop, L.A.M.; Plas, M. van der; Hanssen, A.E.J.; Kogel, A.J. van der

    1996-01-01

    Introduction: Detailed knowledge of radiobiological parameters of the different tissues involved are warranted before HDR- and recently PDR-brachytherapy can be successfully introduced in clinical practice as an alternative to LDR- brachytherapy. The purpose of this study is to determine the α/β ratio and half time of repair of rat spinal cord during continuous irradiation at different dose rates and to investigate the impact of a rapid dose fall off over the spinal cord thickness. Material and methods: Two parallel catheters are inserted on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters were afterloaded with two 192 Ir- wires of 4 cm length each (activity 1- 10 mCi/cm) or connected to the HDR-microSelectron. Serial experiments have been carried out to obtain complete dose response curves at 5 different dose rates, resp. 0.5, 0.9, 1.6, 2.6 and 120 Gy/h. Paralysis of the hindlegs after 5-6 months and histopathological examination of the spinal cord of each animal are used as experimental endpoints. Dose-volume histograms of each irradiated rat have been analysed to evaluate the correlation between dose distribution and biological response and the histopathological damage seen. Results: The distribution of the histological damage was a good reflection of the rapid dose fall-off over the spinal cord, with white matter necrosis or demyelination predominantly seen in the dorsal tracts of the spinal cord or dorsal roots. With each reduction of the dose rate, spinal cord tolerance was significantly increased, with a maximum dose rate factor of 4.3 if the dose rate was reduced from 120 Gy/h to 0.53 Gy/h. Estimates of the repair parameters using different types of analysis revealed an α/β ratio of 2.44 Gy and a (mono- exponential) half time of repair (=t (1(2)) ) of 1.43 hours; for the maximum of 150 % of the prescribed dose these values were 3.67 Gy and 1.43 hours respectively. Conclusions: Spinal cord radiation tolerance is

  13. 75 FR 53586 - Bifenazate; Pesticide Tolerances

    Science.gov (United States)

    2010-09-01

    ... characterized and were seen at dose(s) that produce evidence of overt systemic toxicity. These effects included... system, and these findings may be due to secondary effect of overt systemic toxicity. Further, there is... Adequate enforcement methodology is available to enforce the tolerance expression. High-performance liquid...

  14. Pharmacokinetics, Safety and Tolerability of Melissa officinalis Extract which Contained Rosmarinic Acid in Healthy Individuals: A Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Moeko Noguchi-Shinohara

    Full Text Available The aim of this study was to evaluate the safety, tolerability and pharmacokinetics of single dose of Melissa officinalis extract which contained rosmarinic acid, including food-effects in healthy individuals. A total of eleven healthy individuals were randomly assigned to treatment arms in the two studies [Study 1 (fasted state and Study 2 (fed state]. Rosmarinic acid in serum was measured by a coulometric detection method using High-Performance Liquid Chromatography electrochemical detector. The serum concentration of total rosmarinic acid peaked at 1 hour after administration of Melissa officinalis extract containing 500mg rosmarinic acid in fasted state, with a maximum serum concentration 162.20 nmol/ L. The area under the curve for intact rosmarinic acid was calculated from the serum concentration-time profile to be 832.13 nmol • hour/ L. Food intake increases area under the curve and delayed time at which the maximum serum concentration. Rosmarinic acid supplementation did not affect liver, kidney, or blood cell function parameters. No adverse event was reported by any of the participants due to the study treatment. Single dose of Melissa officinalis extract containing 500 mg rosmarinic acid appears to be safe and tolerable in healthy individuals. Food intake increased the exposure of rosmarinic acid and delayed absorption of rosmarinic acid in healthy individuals.

  15. Irradiation of meningioma: a prototype circumscribed tumor for planning high-dose irradiation of the brain

    International Nuclear Information System (INIS)

    Friedman, M.

    1977-01-01

    The purpose of this report is to provide specific data concerning the radiation dose required to destroy meningioma, and to demonstrate that radiation doses much greater than the alleged tolerance dose, can be administered to the brain in some patients. Most meninglomas are not responsive to irradiation, but, some surgically incurable lesions benefit from irradiation with radically high doses to small volumes of tissue. The arrest of 7 of 12 consecutive meningiomas in adults for periods of 2 to 17 years following maximum tumor doses up to 8800 R in 40 days is reported in this paper. All patients, when irradiated, had active tumor in the form of inoperable primary tumor, recurrence, or known postoperative residual tumor. Three of the successful results were achieved with orthovoltage radiation. The incidence of brain damage may be acceptable to the patient when it is related to arrest of tumor growth but he must be forewarned of possible brain damage. The factors influencing the radioresponsiveness of meningioma are: the required tumor lethal dose, histology and vascularity of the tumor, anatomical site in the brain, treatment technique for each tumor site, small size of the treated volume, growth rate of the tumor, displacement of normal brain tissue by tumor, inherent individual variations of tumor and normal tissues, quality of the radiation, and tolerance of normal brain tissues. The role of these factors is discussed in the light of modern radiobiological concepts

  16. Pharmacokinetics, pharmacodynamics, and tolerability of verinurad, a selective uric acid reabsorption inhibitor, in healthy adult male subjects

    Directory of Open Access Journals (Sweden)

    Shen Z

    2017-07-01

    Full Text Available Zancong Shen,1 Michael Gillen,2 Jeffrey N Miner,1 Gail Bucci,1 David M Wilson,1 Jesse W Hall1 1Ardea Biosciences, Inc., San Diego, CA, 2AstraZeneca, Gaithersburg, MD, USA Purpose: Verinurad (RDEA3170 is a selective uric acid reabsorption inhibitor in clinical development for the treatment of gout and asymptomatic hyperuricemia. The aim of this study was to evaluate the pharmacokinetics, pharmacodynamics, and tolerability of verinurad in healthy adult males.Subjects and methods: This was a Phase I, randomized, double-blind, placebo-controlled, single and multiple ascending dose study. Panels of eight male subjects received a single oral dose of verinurad or placebo in either a fasted or fed state; panels of 10–12 male subjects received ascending doses of once-daily verinurad or placebo in a fasted state for 10 days. Serial blood and urine samples were assayed for verinurad and uric acid. Safety was assessed by adverse event (AE reports, laboratory tests, vital signs, and electrocardiograms (ECGs.Results: A total of 81 adult males completed the study. Following single doses of verinurad, maximum observed plasma concentration (Cmax and area under the plasma concentration–time curve (AUC increased in a dose-proportional manner; Cmax occurred at 0.5–0.75 hours and 1.25 hours in the fasted and fed states, respectively. Food decreased AUC by 23% and Cmax by 37%-53%. There was a modest accumulation of verinurad following multiple daily doses. Verinurad reduced serum urate levels by up to 62% (40 mg, single dose and 61% (10 mg, multiple dose. The increase in urinary excretion of uric acid was greatest in the first 6 hours after dosing and was still evident ≥24 hours for verinurad doses ≥2 mg. Verinurad was well tolerated at all doses. No serious AEs, severe AEs, discontinuations due to AEs, or clinically significant laboratory or ECG abnormalities were reported.Conclusion: Single and multiple doses of verinurad were well tolerated

  17. [Doses to organs at risk in conformational and stereotactic body radiation therapy: Liver].

    Science.gov (United States)

    Debbi, K; Janoray, G; Scher, N; Deutsch, É; Mornex, F

    2017-10-01

    The liver is an essential organ that ensures many vital functions such as metabolism of bilirubin, glucose, lipids, synthesis of coagulation factors, destruction of many toxins, etc. The hepatic parenchyma can be irradiated during the management of digestive tumors, right basithoracic, esophagus, abdomen in toto or TBI. In addition, radiotherapy of the hepatic area, which is mainly stereotactic, now occupies a central place in the management of primary or secondary hepatic tumors. Irradiation of the whole liver, or part of it, may be complicated by radiation-induced hepatitis. It is therefore necessary to respect strict dosimetric constraints both in stereotactic and in conformational irradiation in order to limit the undesired irradiation of the hepatic parenchyma which may vary according to the treatment techniques, the basic hepatic function or the lesion size. The liver is an organ with a parallel architecture, so the average tolerable dose in the whole liver should be considered rather than the maximum tolerable dose at one point. The purpose of this article is to propose a development of dose recommendations during conformation or stereotactic radiotherapy of the liver. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  18. Phase I dose escalation safety study of nanoparticulate paclitaxel (CTI 52010 in normal dogs

    Directory of Open Access Journals (Sweden)

    Axiak SM

    2011-10-01

    Full Text Available Sandra M Axiak1, Kim A Selting1, Charles J Decedue2, Carolyn J Henry1,3, Deborah Tate1, Jahna Howell2, K James Bilof1, Dae Y Kim4 1Department of Veterinary Medicine and Surgery, University of Missouri, Columbia, MO, USA; 2CritiTech Inc, Lawrence, KS, USA; 3Department of Internal Medicine, Division of Hematology and Oncology; 4Department of Veterinary Pathobiology, University of Missouri, Columbia, MO, USA Background: Paclitaxel is highly effective in the treatment of many cancers in humans, but cannot be routinely used in dogs as currently formulated due to the exquisite sensitivity of this species to surfactant-solubilizing agents. CTI 52010 is a formulation of nanoparticulate paclitaxel consisting of drug and normal saline. Our objectives were to determine the maximally tolerated dose, dose-limiting toxicities, and pharmacokinetics of CTI 52010 administered intravenously to normal dogs. Methods: Three normal adult hound dogs were evaluated by physical examination, complete blood count, chemistry profile, and urinalysis. Dogs were treated with staggered escalating dosages of CTI 52010 with a 28-day washout. All dogs were treated with a starting dosage of 40 mg/m2, and subsequent dosages were escalated at 50% (dog 1, 100% (dog 2, or 200% (dog 3 with each cycle, to a maximum of 240 mg/m2. Dogs were monitored by daily physical assessment and weekly laboratory evaluation. Standard criteria were used to grade adverse events. Plasma was collected at regular intervals to determine pharmacokinetics. Dogs were euthanized humanely, and necropsy was performed one week after the last treatment. Results: The dose-limiting toxicity was grade 4 neutropenia and the maximum tolerated dosage was 120 mg/m2. Grade 1–2 gastrointestinal toxicity was noted at higher dosages. Upon post mortem evaluation, no evidence of organ (liver, kidney, spleen toxicity was noted. Conclusion: CTI 52010 was well tolerated when administered intravenously to normal dogs. A starting

  19. Pharmacokinetics and tolerability of the new second-generation nonnucleoside reverse- transcriptase inhibitor KM-023 in healthy subjects

    Directory of Open Access Journals (Sweden)

    Cha YJ

    2014-09-01

    Full Text Available Yu-Jung Cha,1,* Kyoung Soo Lim,2,* Min-Kyu Park,1 Stephen Schneider,3 Brian Bray,3 Myung-Chol Kang,3 Jae-Yong Chung,1 Seo Hyun Yoon,1 Joo-Youn Cho,1 Kyung-Sang Yu11Department of Clinical Pharmacology and Therapeutics, Seoul National University College of Medicine and Hospital, Seoul, South Korea; 2Department of Clinical Pharmacology and Therapeutics, CHA University School of Medicine and CHA Bundang Medical Center, Seongnam, South Korea; 3Kainos Medicine USA Inc., Morrisville, NC, USA *These authors contributed equally to this workBackground: KM-023 is a new second-generation nonnucleoside reverse-transcriptase inhibitor that is under development for the treatment of human immunodeficiency virus (HIV type 1 infection. Objective: This study determined KM-023 tolerability and pharmacokinetic characteristics in healthy subjects. Materials and methods: A randomized, double-blinded, placebo-controlled, dose-escalation study was conducted in 80 healthy South Korean male volunteers. The subjects were allocated to single- or multiple-dose (once daily for 7 days groups that received 75, 150, 300, or 600 mg drug or placebo in a 4:1 ratio. Safety and pharmacokinetic assessments were performed during the study. Plasma and urine concentrations were quantified using liquid chromatography–tandem mass spectrometry. Results: The average maximum concentration (Cmax and area under the concentration–time curve from time 0 to infinity (AUC∞ values of KM-023 for the 75–600 mg doses in the single-dose study ranged from 440.2 ng/mL to 1,245.4 ng/mL and 11,142.4 ng • h/mL to 33,705.6 ng • h/mL, respectively. Values of the mean Cmax at a steady state and AUC within the dosing interval ranged from 385.1 ng/mL to 1,096.7 ng/mL and 3,698.9 ng • h/mL to 10,232.6 ng • h/mL, respectively, following 75–600 mg doses in the multiple-dose study. Dose proportionality was not observed for KM-023. KM-023 showed a 0.6-fold accumulation after multiple doses in the 600

  20. Tolerance of cranial nerves of the cavernous sinus to radiosurgery

    International Nuclear Information System (INIS)

    Tishler, R.B.; Loeffler, J.S.; Alexander, E. III; Kooy, H.M.; Lunsford, L.D.; Duma, C.; Flickinger, J.C.

    1993-01-01

    Stereotactic radiosurgery is becoming a more accepted treatment option for benign, deep seated intracranial lesions. However, little is known about the effects of large single fractions of radiation on cranial nerves. This study was undertaken to assess the effect of radiosurgery on the cranial nerves of the cavernous sinus. The authors examined the tolerance of cranial nerves (II-VI) following radiosurgery for 62 patients (42/62 with meningiomas) treated for lesions within or near the cavernous sinus. Twenty-nine patients were treated with a modified 6 MV linear accelerator (Joint Center for Radiation Therapy) and 33 were treated with the Gamma Knife (University of Pittsburgh). Three-dimensional treatment plans were retrospectively reviewed and maximum doses were calculated for the cavernous sinus and the optic nerve and chiasm. Median follow-up was 19 months (range 3-49). New cranial neuropathies developed in 12 patients from 3-41 months following radiosurgery. Four of these complications involved injury to the optic system and 8 (3/8 transient) were the result of injury to the sensory or motor nerves of the cavernous sinus. There was no clear relationship between the maximum dose to the cavernous sinus and the development of complications for cranial nerves III-VI over the dose range used (1000-4000 cGy). For the optic apparatus, there was a significantly increased incidence of complications with dose. Four of 17 patients (24%) receiving greater than 800 cGy to any part of the optic apparatus developed visual complications compared with 0/35 who received less than 800 cGy (p = 0.009). Radiosurgery using tumor-controlling doses of up to 4000 cGy appears to be a relatively safe technique in treating lesions within or near the sensory and motor nerves (III-VI) of the cavernous sinus. The dose to the optic apparatus should be limited to under 800 cGy. 21 refs., 4 tabs

  1. Axitinib in combination with pembrolizumab in patients with advanced renal cell cancer: a non-randomised, open-label, dose-finding, and dose-expansion phase 1b trial.

    Science.gov (United States)

    Atkins, Michael B; Plimack, Elizabeth R; Puzanov, Igor; Fishman, Mayer N; McDermott, David F; Cho, Daniel C; Vaishampayan, Ulka; George, Saby; Olencki, Thomas E; Tarazi, Jamal C; Rosbrook, Brad; Fernandez, Kathrine C; Lechuga, Mariajose; Choueiri, Toni K

    2018-03-01

    Previous studies combining PD-1 checkpoint inhibitors with tyrosine kinase inhibitors of the VEGF pathway have been characterised by excess toxicity, precluding further development. We hypothesised that axitinib, a more selective VEGF inhibitor than others previously tested, could be combined safely with pembrolizumab (anti-PD-1) and yield antitumour activity in patients with treatment-naive advanced renal cell carcinoma. In this ongoing, open-label, phase 1b study, which was done at ten centres in the USA, we enrolled patients aged 18 years or older who had advanced renal cell carcinoma (predominantly clear cell subtype) with their primary tumour resected, and at least one measureable lesion, Eastern Cooperative Oncology Group performance status 0-1, controlled hypertension, and no previous systemic therapy for renal cell carcinoma. Eligible patients received axitinib plus pembrolizumab in a dose-finding phase to estimate the maximum tolerated dose, and additional patients were enrolled into a dose-expansion phase to further establish safety and determine preliminary efficacy. Axitinib 5 mg was administered orally twice per day with pembrolizumab 2 mg/kg given intravenously every 3 weeks. We assessed safety in all patients who received at least one dose of axitinib or pembrolizumab; antitumour activity was assessed in all patients who received study treatment and had an adequate baseline tumour assessment. The primary endpoint was investigator-assessed dose-limiting toxicity during the first two cycles (6 weeks) to estimate the maximum tolerated dose and recommended phase 2 dose. This study is registered with ClinicalTrials.gov, number NCT02133742. Between Sept 23, 2014, and March 25, 2015, we enrolled 11 patients with previously untreated advanced renal cell carcinoma to the dose-finding phase and between June 3, 2015, and Oct 13, 2015, we enrolled 41 patients to the dose-expansion phase. All 52 patients were analysed together. No unexpected toxicities were

  2. Phase I dose-escalation study of the c-Met tyrosine kinase inhibitor SAR125844 in Asian patients with advanced solid tumors, including patients with MET-amplified gastric cancer

    OpenAIRE

    Shitara, Kohei; Kim, Tae Min; Yokota, Tomoya; Goto, Masahiro; Satoh, Taroh; Ahn, Jin-Hee; Kim, Hyo Song; Assadourian, Sylvie; Gomez, Corinne; Harnois, Marzia; Hamauchi, Satoshi; Kudo, Toshihiro; Doi, Toshihido; Bang, Yung-Jue

    2017-01-01

    SAR125844 is a potent and selective inhibitor of the c-Met kinase receptor. This was an open-label, phase I, multicenter, dose-escalation, and dose-expansion trial of SAR125844 in Asian patients with solid tumors, a subgroup of whom had gastric cancer and MET amplification (NCT01657214). SAR125844 was administered by intravenous infusion (260–570 mg/m2) on days 1, 8, 15, and 22 of each 28-day cycle. Objectives were to determine the maximum tolerated dose (MTD) and to evaluate SAR125844 safety...

  3. Indexes of carbohydrate exchange (CE) and results of toleration test to glucose after effect of low dose of ionizing radiation in late periods

    International Nuclear Information System (INIS)

    Akhmetov, E.A.

    1997-01-01

    The indexes of tolerance test to glucose and values of generalized criterion (GC) being information index of CE system status were determined for 100 liquidators of Chernobyl accident with purpose of study of carbohydrate exchange (CE) status. Analysis of these mean values was carried out according to participation data in liquidation works, exposition duration, rate of radioactive contamination of zone, absorbed dose of external irradiation and age of examined persons. Contribution of each studied components of radiation factor on CE status is estimated. It is determined that both the absorbed dose and the exposition duration are main factors influencing on CE. In examined group there were 32 men with disorders of CE , 20 of them (GC=18.33±0.48) were placed to group of higher risk, 9 men have high tolerance of organism to glucose (GC=32.84±1.37) and 3 men have diabetes of II type (GC=68.6±2.16). Frequency of cases of liquidators' of Chernobyl accident CE disorders allows to made conclusion that ills have dis-function of endocrine section of pancreas

  4. Caffeine tolerance: behavioral, electrophysiological and neurochemical evidence

    International Nuclear Information System (INIS)

    Chou, D.T.; Khan, S.; Forde, J.; Hirsh, K.R.

    1985-01-01

    The development of tolerance to the stimulatory action of caffeine upon mesencephalic reticular neurons and upon spontaneous locomotor activity was evaluated in rats after two weeks of chronic exposure to low doses of caffeine (5-10 mg/kg/day via their drinking water). These doses are achievable through dietary intake of caffeine-containing beverages in man. Concomitant measurement of [ 3 H]-CHA binding in the mesencephalic reticular formation was also carried out in order to explore the neurochemical basis of the development of tolerance. Caffeine, 2.5 mg/kg i.v., markedly increased the firing rate of reticular neurons in caffeine naive rats but failed to modify the neuronal activity in a group exposed chronically to low doses of caffeine. In addition, in spontaneous locomotor activity studies, the data show a distinct shift to the right of the caffeine dose-response curve in caffeine pretreated rats. These results clearly indicate that tolerance develops to the stimulatory action of caffeine upon the reticular formation at the single neuronal activity level as well as upon spontaneous locomotor activity. Furthermore, in chronically caffeine exposed rats, an increase in the number of binding sites for [ 3 H]-CHA was observed in reticular formation membranes without any change in receptor affinity. 28 references, 4 figures

  5. Oral sodium phenylbutyrate in patients with recurrent malignant gliomas: a dose escalation and pharmacologic study.

    Science.gov (United States)

    Phuphanich, Surasak; Baker, Sharyn D; Grossman, Stuart A; Carson, Kathryn A; Gilbert, Mark R; Fisher, Joy D; Carducci, Michael A

    2005-04-01

    We determined the maximum tolerated dose (MTD), toxicity profile, pharmacokinetic parameters, and preliminary efficacy data of oral sodium phenylbutyrate (PB) in patients with recurrent malignant gliomas. Twenty-three patients with supratentorial recurrent malignant gliomas were enrolled on this dose escalation trial. Four dose levels of PB were studied: 9, 18, 27, and 36 g/day. Data were collected to assess toxicity, response, survival, and pharmacokinetics. All PB doses of 9, 18, and 27 g/day were well tolerated. At 36 g/day, two of four patients developed dose-limiting grade 3 fatigue and somnolence. At the MTD of 27 g/day, one of seven patients developed reversible grade 3 somnolence. Median survival from time of study entry was 5.4 months. One patient had a complete response for five years, and no partial responses were noted, which yielded an overall response rate of 5%. Plasma concentrations of 706, 818, 1225, and 1605 muM were achieved with doses of 9, 18, 27, and 36 g/day, respectively. The mean value for PB clearance in this patient population was 22 liters/h, which is significantly higher than the 16 liters/h reported in patients with other malignancies who were not receiving P450 enzyme-inducing anticonvulsant drugs (P = 0.038). This study defines the MTD and recommended phase 2 dose of PB at 27 g/day for heavily pretreated patients with recurrent gliomas. The pharmacology of PB appears to be affected by concomitant administration of P450-inducing anticonvulsants.

  6. In vivo assessment of the tolerance dose of small liver volumes after single-fraction HDR irradiation

    International Nuclear Information System (INIS)

    Ricke, Jens; Seidensticker, Max; Luedemann, Lutz; Pech, Maciej; Wieners, Gero; Hengst, Susanne; Mohnike, Konrad; Cho, Chie Hee; Lopez Haenninen, Enrique; Al-Abadi, Hussain; Felix, Roland; Wust, Peter

    2005-01-01

    Purpose: To prospectively assess a dose-response relationship for small volumes of liver parenchyma after single-fraction irradiation. Methods and Materials: Twenty-five liver metastases were treated by computed tomography (CT)-guided interstitial brachytherapy. Magnetic resonance imaging was performed 1 day before and 3 days and 6, 12, and 24 weeks after therapy. MR sequences included T1-w gradient echo (GRE) enhanced by hepatocyte-targeted gadobenate dimeglumine. All MRI data sets were merged with 3D dosimetry data and evaluated by two radiologists. The reviewers indicated the border of hyperintensity on T2-w images (edema) or hypointensity on T1-w images (loss of hepatocyte function). Based on the total 3D data, a dose-volume histogram was calculated. We estimated the threshold dose for either edema or function loss as the D 90 , i.e., the dose achieved in at least 90% of the pseudolesion volume. Results: Between 3 days and 6 weeks, the extension of the edema increased significantly from the 12.9 Gy isosurface to 9.9 Gy (standard deviation [SD], 3.3 and 2.6). No significant change was detected between 6 and 12 weeks. After 24 weeks, the edematous tissue had shrunk significantly to 14.7 Gy (SD, 4.2). Three days postbrachytherapy, the D 90 for hepatocyte function loss reached the 14.9 Gy isosurface (SD, 3.9). At 6 weeks, the respective zone had increased significantly to 9.9 Gy (SD, 2.3). After 12 and 24 weeks, the dysfunction volume had decreased significantly to the 11.9 Gy and 15.2 Gy isosurface, respectively (SD, 3 and 4.1). Conclusions: The 95% interval from 7.6 to 12.2 Gy found as the minimal hepatocyte tolerance after 6 weeks accounts for the radiobiologic variations found in CT-guided brachytherapy, including heterogeneous dose rates by variable catheter arrays

  7. Chronic administration of the HNO donor Angeli's salt does not lead to tolerance, cross-tolerance, or endothelial dysfunction: comparison with GTN and DEA/NO.

    Science.gov (United States)

    Irvine, Jennifer C; Kemp-Harper, Barbara K; Widdop, Robert E

    2011-05-01

    Nitroxyl (HNO) displays distinct pharmacology to its redox congener nitric oxide (NO(•)) with therapeutic potential in the treatment of heart failure. It remains unknown if HNO donors are resistant to tolerance development following chronic in vivo administration. Wistar-Kyoto rats received a 3-day subcutaneous infusion of one of the NO(•) donors, glyceryl trinitrate (GTN) or diethylamine/NONOate (DEA/NO), or the HNO donor Angeli's salt (AS). GTN infusion (10 μg/kg/min) resulted in significantly blunted depressor responses to intravenous bolus doses of GTN, demonstrating tolerance development. By contrast, infusion with AS (20 μg/kg/min) or DEA/NO (2 μg/kg/min) did not alter their subsequent depressor responses. Similarly, ex vivo vasorelaxation responses in isolated aortae revealed that GTN infusion elicited a significant 6-fold decrease in the sensitivity to GTN and reduction in the maximum response to acetylcholine (ACh). Chronic infusion of AS or DEA/NO had no effect on subsequent vasorelaxation responses to themselves or to ACh. No functional cross-tolerance between nitrovasodilators was evident, either in vivo or ex vivo, although an impaired ability of a nitrovasodilator to increase tissue cGMP content was not necessarily indicative of a reduced functional response. In conclusion, HNO donors may represent novel therapies for cardiovascular disease with therapeutic potential over clinically used organic nitrates.

  8. Oxycodone recycling: a novel hypothesis of opioid tolerance development in humans.

    Science.gov (United States)

    Linares, Oscar A; Fudin, Jeffrey; Schiesser, William E; Linares, Annemarie Daly; Boston, Raymond C

    2014-09-01

    We hypothesize that oxycodone (OC) recycling promotes sustained synaptic OC content, which prolongs OC's exposure to local μ-opioid receptors (μORs). In that way, OC recycling gives rise to OC tolerance in humans. To pilot test our hypothesis, we developed a whole-body OC mass transport tolerance recovery model. The model derived quantifiable measure of tolerance is TΩ. TΩ estimates OC's tolerance recovery in days; It is defined as the rate of recovery of OC's pharmacologic response after OC is stopped. We studied a random sample of five opioid intolerant healthy male subjects with no history of opioid or illicit drug use, or comorbidities in silico. Subjects were age 24.5 ± 2.3 yr (all values mean ± SD), weight 93 ± 20 kg, and CYP2D6 EM phenotype. Each subject was studied under two experimental conditions: (1) administration of a single oral dose of OC 12 ± 7 mg; and, after complete washout of OC from the intravascular pool, (2) administration of repetitive oral OC doses every 4h for 5 half-lives (t1/2 = 4.5h)-after which time steady-state was assumed. Repetitive OC dose TΩ fell 61% compared to single OC dose TΩ (5.2 ± 1.1 vs. 3.5 ± 0.7 days, p = 0.001). The fall in TΩ was associated with a significant 3-fold increase in extravascular OC content, which was accompanied by 2-fold increase in OC spillover from the extravascular pool, into the intravascular pool. Thus, the model predicted that a single dose of orally administered OC could give rise to tolerance. This is consistent with the widely held view of acute opioid tolerance. In addition, the dynamic changes accompanying repetitive OC dosing suggested that local unbound OC gave rise to both higher extravascular OC content and increased OC spillover. This reflects that OC stimulated endocytosis of μORs was accompanied by a reduction in the availability OC responsive neuroeffector cell surface μOR binding sites. We conclude that our hypothesis extends current concepts of opioid tolerance

  9. Disulfonated tetraphenyl chlorin (TPCS2a)-induced photochemical internalisation of bleomycin in patients with solid malignancies: a phase 1, dose-escalation, first-in-man trial.

    Science.gov (United States)

    Sultan, Ahmed A; Jerjes, Waseem; Berg, Kristian; Høgset, Anders; Mosse, Charles A; Hamoudi, Rifat; Hamdoon, Zaid; Simeon, Celia; Carnell, Dawn; Forster, Martin; Hopper, Colin

    2016-09-01

    Photochemical internalisation, a novel minimally invasive treatment, has shown promising preclinical results in enhancing and site-directing the effect of anticancer drugs by illumination, which initiates localised chemotherapy release. We assessed the safety and tolerability of a newly developed photosensitiser, disulfonated tetraphenyl chlorin (TPCS2a), in mediating photochemical internalisation of bleomycin in patients with advanced and recurrent solid malignancies. In this phase 1, dose-escalation, first-in-man trial, we recruited patients (aged ≥18 to internalisation were either local, resulting from the local inflammatory process, or systemic, mostly as a result of the skin-photosensitising effect of TPCS2a. The most common grade 3 or worse adverse events were unexpected higher transient pain response (grade 3) localised to the treatment site recorded in nine patients, and respiratory failure (grade 4) noted in two patients. One dose-limiting toxicity was reported in the 1·0 mg/kg cohort (skin photosensitivity [grade 2]). Dose-limiting toxicities were reported in two of three patients at a TPCS2a dose of 1·5 mg/kg (skin photosensitivity [grade 3] and wound infection [grade 3]); thus, the maximum tolerated dose of TPCS2a was 1·0 mg/kg. Administration of TPCS2a was found to be safe and tolerable by all patients. No deaths related to photochemical internalisation treatment occurred. TPCS2a-mediated photochemical internalisation of bleomycin is safe and tolerable. We identified TPCS2a 0·25 mg/kg as the recommended treatment dose for future trials. PCI Biotech. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. TOLERANCE SENSITIVITY ANALYSIS: THIRTY YEARS LATER

    Directory of Open Access Journals (Sweden)

    Richard E. Wendell

    2010-12-01

    Full Text Available Tolerance sensitivity analysis was conceived in 1980 as a pragmatic approach to effectively characterize a parametric region over which objective function coefficients and right-hand-side terms in linear programming could vary simultaneously and independently while maintaining the same optimal basis. As originally proposed, the tolerance region corresponds to the maximum percentage by which coefficients or terms could vary from their estimated values. Over the last thirty years the original results have been extended in a number of ways and applied in a variety of applications. This paper is a critical review of tolerance sensitivity analysis, including extensions and applications.

  11. Deconstructing tolerance with clobazam

    Science.gov (United States)

    Wechsler, Robert T.; Sankar, Raman; Montouris, Georgia D.; White, H. Steve; Cloyd, James C.; Kane, Mary Clare; Peng, Guangbin; Tworek, David M.; Shen, Vivienne; Isojarvi, Jouko

    2016-01-01

    Objective: To evaluate potential development of tolerance to adjunctive clobazam in patients with Lennox-Gastaut syndrome. Methods: Eligible patients enrolled in open-label extension study OV-1004, which continued until clobazam was commercially available in the United States or for a maximum of 2 years outside the United States. Enrolled patients started at 0.5 mg·kg−1·d−1 clobazam, not to exceed 40 mg/d. After 48 hours, dosages could be adjusted up to 2.0 mg·kg−1·d−1 (maximum 80 mg/d) on the basis of efficacy and tolerability. Post hoc analyses evaluated mean dosages and drop-seizure rates for the first 2 years of the open-label extension based on responder categories and baseline seizure quartiles in OV-1012. Individual patient listings were reviewed for dosage increases ≥40% and increasing seizure rates. Results: Data from 200 patients were included. For patients free of drop seizures, there was no notable change in dosage over 24 months. For responder groups still exhibiting drop seizures, dosages were increased. Weekly drop-seizure rates for 100% and ≥75% responders demonstrated a consistent response over time. Few patients had a dosage increase ≥40% associated with an increase in seizure rates. Conclusions: Two-year findings suggest that the majority of patients do not develop tolerance to the antiseizure actions of clobazam. Observed dosage increases may reflect best efforts to achieve seizure freedom. It is possible that the clinical development of tolerance to clobazam has been overstated. ClinicalTrials.gov identifier: NCT00518713 and NCT01160770. Classification of evidence: This study provides Class III evidence that the majority of patients do not develop tolerance to clobazam over 2 years of treatment. PMID:27683846

  12. Tolerance of human skin applying pulsed brachytherapy with large afterloading moulds

    International Nuclear Information System (INIS)

    Fritz, Peter; Hensley, Frank W.; Berns, Christiane; Schraube, Peter; Wannenmacher, Michael

    1995-01-01

    Purpose: The concept of pulsed brachytherapy suggested by Brenner and Hall requires an unusual fractionation scheme. The effectiveness and sequelae of this new irradiation method was observed on patients with disseminated cutaneous metastases of breast cancer. Materials and Methods: A flexible, re-usable skin mould (weight 110 g) was developed for use with a PDR afterload. An array of 18 parallel catheters (2 mm diameter) at equal distances of 10 mm was constructed by fixation of the catheters in a plastic wire mesh. The array is sewn between two foam rubber slabs of 5 mm thickness to provide a defined constant distance to the skin. Irradiations are performed up to a maximum field size of 17 x 23,5 cm 2 with a nominal 37 GBq Ir-192 source in pulses of 1 Gy per hour at the skin surface. The dose distribution is geometrically optimized to provide a homogeneous skin dose (100±10%). The 80% dose level lies at 5 mm below the skin surface. 20 patients suffering from cutaneous metastases at the thoracic wall were treated with 22 fields (area irradiated: 100-919 cm 2 ) at total doses of 40 to 50 Gy applying two PDR courses with a pause of 4 to 6 weeks. 12 of the fields were previously irradiated with external beam therapy to doses of 40 to 60 Gy at 7 to 22 months in advance. Results: Complete remissions (CR) were achieved in 21 out of 22 fields. (18(20)) patients were free of relapse at the time of death or evaluation. Pre-irradiated fields (n=12): follow-up times 6-21,5 months (median: 11,5 months). CR: (11(12)) fields. Recurrencies:(2(12)) fields. Maximum degree of early skin reactions: marked erythema: (8(12)) fields; epitheliolysis (>50% field size): (4(12)) fields. Intermediate skin reactions after minimum follow-up of 6 months: pigmentation/atrophy: (8(12)) fields; marked teleangiectasia: (3(12)) fields; small skin necrosis:(1(12)) fields. Newly irradiated fields (n=11): follow-up: 6-13,5 months (median:8 month). CR: (11(11)) fields. Recurrencies:(0(11)) fields

  13. Effects of exendin-4 on glucose tolerance, insulin secretion, and beta-cell proliferation depend on treatment dose, treatment duration and meal contents

    International Nuclear Information System (INIS)

    Arakawa, Masayuki; Ebato, Chie; Mita, Tomoya; Hirose, Takahisa; Kawamori, Ryuzo; Fujitani, Yoshio; Watada, Hirotaka

    2009-01-01

    Beta-cell proliferation is regulated by various metabolic demands including peripheral insulin resistance, obesity, and hyperglycemia. In addition to enhancement of glucose-induced insulin secretion, agonists for glucagon-like peptide-1 receptor (GLP-1R) stimulate proliferation and inhibit apoptosis of beta-cells, thereby probably preserve beta-cell mass. To evaluate the beta-cell preserving actions of GLP-1R agonists, we assessed the acute and chronic effects of exendin-4 on beta-cell proliferation, mass and glucose tolerance in C57BL/6J mice under various conditions. Short-term administration of high-dose exendin-4 transiently stimulated beta-cell proliferation. Comparative transcriptomic analysis showed upregulation of IGF-1 receptor and its downstream effectors in islets. Treatment of mice with exendin-4 daily for 4 weeks (long-term administration) and feeding high-fat diet resulted in significant inhibition of weight gain and improvement of glucose tolerance with reduced insulin secretion and beta-cell mass. These findings suggest that long-term GLP-1 treatment results in insulin sensitization of peripheral organs, rather than enhancement of beta-cell proliferation and function, particularly when animals are fed high-fat diet. Thus, the effects of exendin-4 on glucose tolerance, insulin secretion, and beta-cell proliferation largely depend on treatment dose, duration of treatment and meal contents. While GLP-1 enhances proliferation of beta-cells in some diabetic mice models, our results suggest that GLP-1 stimulates beta-cell growth only when expansion of beta-cell mass is required to meet metabolic demands.

  14. Effects of exendin-4 on glucose tolerance, insulin secretion, and beta-cell proliferation depend on treatment dose, treatment duration and meal contents

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Masayuki; Ebato, Chie; Mita, Tomoya [Department of Medicine, Metabolism and Endocrinology, Juntendo University School of Medicine, Tokyo (Japan); Hirose, Takahisa [Department of Medicine, Metabolism and Endocrinology, Juntendo University School of Medicine, Tokyo (Japan); Center for Therapeutic Innovations in Diabetes, Juntendo University School of Medicine, Tokyo (Japan); Kawamori, Ryuzo [Department of Medicine, Metabolism and Endocrinology, Juntendo University School of Medicine, Tokyo (Japan); Center for Therapeutic Innovations in Diabetes, Juntendo University School of Medicine, Tokyo (Japan); Center for Beta Cell Biology and Regeneration, Juntendo University School of Medicine, Tokyo (Japan); Sportology Center, Juntendo University School of Medicine, Tokyo (Japan); Fujitani, Yoshio, E-mail: fujitani@juntendo.ac.jp [Department of Medicine, Metabolism and Endocrinology, Juntendo University School of Medicine, Tokyo (Japan); Center for Therapeutic Innovations in Diabetes, Juntendo University School of Medicine, Tokyo (Japan); Watada, Hirotaka, E-mail: hwatada@juntendo.ac.jp [Department of Medicine, Metabolism and Endocrinology, Juntendo University School of Medicine, Tokyo (Japan); Sportology Center, Juntendo University School of Medicine, Tokyo (Japan)

    2009-12-18

    Beta-cell proliferation is regulated by various metabolic demands including peripheral insulin resistance, obesity, and hyperglycemia. In addition to enhancement of glucose-induced insulin secretion, agonists for glucagon-like peptide-1 receptor (GLP-1R) stimulate proliferation and inhibit apoptosis of beta-cells, thereby probably preserve beta-cell mass. To evaluate the beta-cell preserving actions of GLP-1R agonists, we assessed the acute and chronic effects of exendin-4 on beta-cell proliferation, mass and glucose tolerance in C57BL/6J mice under various conditions. Short-term administration of high-dose exendin-4 transiently stimulated beta-cell proliferation. Comparative transcriptomic analysis showed upregulation of IGF-1 receptor and its downstream effectors in islets. Treatment of mice with exendin-4 daily for 4 weeks (long-term administration) and feeding high-fat diet resulted in significant inhibition of weight gain and improvement of glucose tolerance with reduced insulin secretion and beta-cell mass. These findings suggest that long-term GLP-1 treatment results in insulin sensitization of peripheral organs, rather than enhancement of beta-cell proliferation and function, particularly when animals are fed high-fat diet. Thus, the effects of exendin-4 on glucose tolerance, insulin secretion, and beta-cell proliferation largely depend on treatment dose, duration of treatment and meal contents. While GLP-1 enhances proliferation of beta-cells in some diabetic mice models, our results suggest that GLP-1 stimulates beta-cell growth only when expansion of beta-cell mass is required to meet metabolic demands.

  15. A comparison of the development of tolerance to ethanol and cross-tolerance to nicotine after chronic ethanol treatment in long- and short-sleep mice.

    Science.gov (United States)

    de Fiebre, C M; Collins, A C

    1993-09-01

    Previous studies have shown that inbred mouse strains differ in the development of tolerance to both nicotine and ethanol, indicating that genetic factors regulate tolerance development. Those mouse strains that are most sensitive to an acute challenge dose of either drug develop the most tolerance to that drug. The ethanol-sensitive long-sleep (LS) mice are more sensitive to several behavioral and physiological effects of nicotine than are the ethanol-resistant short-sleep (SS) mice. The experiments reported here assessed whether the LS and SS mice develop tolerance to ethanol after chronic treatment with ethanol-containing liquid diets and whether cross-tolerance to nicotine also developed. Tolerance and cross-tolerance were measured by assessing the effects of acute challenge doses of drug on Y-maze crossing and rearing activities, heart rate and body temperature. The LS mice developed tolerance to ethanol's effects on three of the four measures and were cross-tolerant to nicotine on all of the measures. In contrast, the SS mice developed tolerance to ethanol for only two of the measures, but failed to develop cross-tolerance to any action of nicotine. These findings support the hypothesis that ethanol and nicotine share sites of action and that common genes regulate responses to these two drugs. Evidence suggests that tolerance to nicotine may be related to an up-regulation of brain nicotinic receptors, at least in some inbred mouse strains, but chronic ethanol treatment did not reproducibly change either [3H]nicotine or alpha-[125I]bungarotoxin binding. Therefore, other mechanisms must underlie the tolerance and cross-tolerance that was seen.

  16. Oral sodium phenylbutyrate in patients with recurrent malignant gliomas: A dose escalation and pharmacologic study1

    Science.gov (United States)

    Phuphanich, Surasak; Baker, Sharyn D.; Grossman, Stuart A.; Carson, Kathryn A.; Gilbert, Mark R.; Fisher, Joy D.; Carducci, Michael A.

    2005-01-01

    We determined the maximum tolerated dose (MTD), toxicity profile, pharmacokinetic parameters, and preliminary efficacy data of oral sodium phenylbutyrate (PB) in patients with recurrent malignant gliomas. Twenty-three patients with supratentorial recurrent malignant gliomas were enrolled on this dose escalation trial. Four dose levels of PB were studied: 9, 18, 27, and 36 g/day. Data were collected to assess toxicity, response, survival, and pharmacokinetics. All PB doses of 9, 18, and 27 g/day were well tolerated. At 36 g/day, two of four patients developed dose-limiting grade 3 fatigue and somnolence. At the MTD of 27 g/day, one of seven patients developed reversible grade 3 somnolence. Median survival from time of study entry was 5.4 months. One patient had a complete response for five years, and no partial responses were noted, which yielded an overall response rate of 5%. Plasma concentrations of 706, 818, 1225, and 1605 μM were achieved with doses of 9, 18, 27, and 36 g/day, respectively. The mean value for PB clearance in this patient population was 22 liters/h, which is significantly higher than the 16 liters/h reported in patients with other malignancies who were not receiving P450 enzyme–inducing anticonvulsant drugs (P = 0.038). This study defines the MTD and recommended phase 2 dose of PB at 27 g/day for heavily pretreated patients with recurrent gliomas. The pharmacology of PB appears to be affected by concomitant administration of P450-inducing anticonvulsants. PMID:15831235

  17. Increased interleukin-1β levels following low dose MDMA induces tolerance against the 5-HT neurotoxicity produced by challenge MDMA

    Science.gov (United States)

    2011-01-01

    Background Preconditioning is a phenomenon by which tolerance develops to injury by previous exposure to a stressor of mild severity. Previous studies have shown that single or repeated low dose MDMA can attenuate 5-HT transporter loss produced by a subsequent neurotoxic dose of the drug. We have explored the mechanism of delayed preconditioning by low dose MDMA. Methods Male Dark Agouti rats were given low dose MDMA (3 mg/kg, i.p.) 96 h before receiving neurotoxic MDMA (12.5 mg/kg, i.p.). IL-1β and IL1ra levels and 5-HT transporter density in frontal cortex were quantified at 1 h, 3 h or 7 days. IL-1β, IL-1ra and IL-1RI were determined between 3 h and 96 h after low dose MDMA. sIL-1RI combined with low dose MDMA or IL-1β were given 96 h before neurotoxic MDMA and toxicity assessed 7 days later. Results Pretreatment with low dose MDMA attenuated both the 5-HT transporter loss and elevated IL-1β levels induced by neurotoxic MDMA while producing an increase in IL-1ra levels. Low dose MDMA produced an increase in IL-1β at 3 h and in IL-1ra at 96 h. sIL-1RI expression was also increased after low dose MDMA. Coadministration of sIL-1RI (3 μg, i.c.v.) prevented the protection against neurotoxic MDMA provided by low dose MDMA. Furthermore, IL-1β (2.5 pg, intracortical) given 96 h before neurotoxic MDMA protected against the 5-HT neurotoxicity produced by the drug, thus mimicking preconditioning. Conclusions These results suggest that IL-1β plays an important role in the development of delayed preconditioning by low dose MDMA. PMID:22114930

  18. Increased interleukin-1β levels following low dose MDMA induces tolerance against the 5-HT neurotoxicity produced by challenge MDMA

    Directory of Open Access Journals (Sweden)

    Mayado Andrea

    2011-11-01

    Full Text Available Abstract Background Preconditioning is a phenomenon by which tolerance develops to injury by previous exposure to a stressor of mild severity. Previous studies have shown that single or repeated low dose MDMA can attenuate 5-HT transporter loss produced by a subsequent neurotoxic dose of the drug. We have explored the mechanism of delayed preconditioning by low dose MDMA. Methods Male Dark Agouti rats were given low dose MDMA (3 mg/kg, i.p. 96 h before receiving neurotoxic MDMA (12.5 mg/kg, i.p.. IL-1β and IL1ra levels and 5-HT transporter density in frontal cortex were quantified at 1 h, 3 h or 7 days. IL-1β, IL-1ra and IL-1RI were determined between 3 h and 96 h after low dose MDMA. sIL-1RI combined with low dose MDMA or IL-1β were given 96 h before neurotoxic MDMA and toxicity assessed 7 days later. Results Pretreatment with low dose MDMA attenuated both the 5-HT transporter loss and elevated IL-1β levels induced by neurotoxic MDMA while producing an increase in IL-1ra levels. Low dose MDMA produced an increase in IL-1β at 3 h and in IL-1ra at 96 h. sIL-1RI expression was also increased after low dose MDMA. Coadministration of sIL-1RI (3 μg, i.c.v. prevented the protection against neurotoxic MDMA provided by low dose MDMA. Furthermore, IL-1β (2.5 pg, intracortical given 96 h before neurotoxic MDMA protected against the 5-HT neurotoxicity produced by the drug, thus mimicking preconditioning. Conclusions These results suggest that IL-1β plays an important role in the development of delayed preconditioning by low dose MDMA.

  19. Maximum likelihood as a common computational framework in tomotherapy

    International Nuclear Information System (INIS)

    Olivera, G.H.; Shepard, D.M.; Reckwerdt, P.J.; Ruchala, K.; Zachman, J.; Fitchard, E.E.; Mackie, T.R.

    1998-01-01

    Tomotherapy is a dose delivery technique using helical or axial intensity modulated beams. One of the strengths of the tomotherapy concept is that it can incorporate a number of processes into a single piece of equipment. These processes include treatment optimization planning, dose reconstruction and kilovoltage/megavoltage image reconstruction. A common computational technique that could be used for all of these processes would be very appealing. The maximum likelihood estimator, originally developed for emission tomography, can serve as a useful tool in imaging and radiotherapy. We believe that this approach can play an important role in the processes of optimization planning, dose reconstruction and kilovoltage and/or megavoltage image reconstruction. These processes involve computations that require comparable physical methods. They are also based on equivalent assumptions, and they have similar mathematical solutions. As a result, the maximum likelihood approach is able to provide a common framework for all three of these computational problems. We will demonstrate how maximum likelihood methods can be applied to optimization planning, dose reconstruction and megavoltage image reconstruction in tomotherapy. Results for planning optimization, dose reconstruction and megavoltage image reconstruction will be presented. Strengths and weaknesses of the methodology are analysed. Future directions for this work are also suggested. (author)

  20. Clinical study of a new therapy for nerve agent poisoning: Ascending dose tolerance study of HI-6 + atropine

    Energy Technology Data Exchange (ETDEWEB)

    Clement, J.G.; Bailey, D.G.; Madill, H.D.; Spence, J.D.

    1993-05-13

    HI-6 was rapidly absorbed from an IM injection site. Maximum HI-6 plasma concentrations of 1.88, 4.96, 8.31 15.0 ug/ml were found 28-36 min after administration and maintained above 4 ug/ml concentration for 0, 39, 112 172.5 min following administration of 62.5, 125, 250 or 500 mg HI-6 + atropine (2 mg), respectively. The calculated half life of HI-6 was 78.2 min following 62.5 mg HI-6 + atropine dose and approximately 64-67 min following 125-500 mg HI-6 + atropine doses. Approximately 50 % of the total dose of HI-6 was eliminated unchanged in the urine. There were significant changes (p < 0.05) in AST, CPK, creatinine and gamma GT following the 500 mg HI-6 + atropine dose but they were not considered to be clinically significant. Urinalysis, hematology and semen analysis over the 24 hr observation period was uneventful. There were no clinically significant changes in heart rate or ECG trace, respiration or blood pressure, visual and mental acuity following HI-6 + atropine.

  1. 76 FR 22045 - Fluopicolide; Pesticide Tolerances

    Science.gov (United States)

    2011-04-20

    ... regulation establishes tolerances for residues of fluopicolide and its metabolites in or on multiple... occurred at dose levels where significant maternal toxicity (severe body weight gain decrements and...

  2. Effectiveness and tolerance of long-term malaria prophylaxis with mefloquine. Need for a better dosing regimen.

    Science.gov (United States)

    Lobel, H O; Bernard, K W; Williams, S L; Hightower, A W; Patchen, L C; Campbell, C C

    1991-01-16

    To measure the effectiveness and tolerance of long-term malaria prophylaxis with mefloquine, the incidence of Plasmodium falciparum malaria and of adverse reactions was compared in Peace Corps volunteers in West Africa who took mefloquine every 2 weeks and in volunteers who took chloroquine phosphate weekly. Mefloquine was only 63% more effective than chloroquine; the monthly incidence of P falciparum infections was one case per 100 volunteers who took mefloquine and 2.7 cases per 100 volunteers who took chloroquine. Using daily proguanil (chloroguanide) hydrochloride in addition to chloroquine did not provide additional protection. All mefloquine prophylaxis failures occurred during the second week of the every-2-weeks dosing regimen in volunteers who had used mefloquine for more than 2 months. Blood concentrations of mefloquine were lower during the second week of the alternate-week regimen than during the first week, suggesting that blood levels are too low during the second week to suppress parasitemia. No serious adverse reactions were observed. The results indicate that a dosing regimen of 250 mg of mefloquine weekly should be considered for travelers to areas with chloroquine-resistant P falciparum malaria.

  3. Dietary lecithin potentiates thermal tolerance and cellular stress protection of milk fish (Chanos Chanos) reared under low dose endosulfan-induced stress.

    Science.gov (United States)

    Kumar, Neeraj; Minhas, P S; Ambasankar, K; Krishnani, K K; Rana, R S

    2014-12-01

    Endosulfan is an organochlorine pesticide commonly found in aquatic environments that has been found to reduce thermal tolerance of fish. Lipotropes such as the food additive, Lecithin has been shown to improve thermal tolerance in fish species. This study was conducted to evaluate the role of lipotropes (lecithin) for enhancing the thermal tolerance of Chanos chanos reared under sublethal low dose endosulfan-induced stress. Two hundred and twenty-five fish were distributed randomly into five treatments, each with three replicates. Four isocaloric and isonitrogenous diets were prepared with graded levels of lecithin: normal water and fed with control diet (En0/L0), endosulfan-treated water and fed with control diet (En/L0), endosulfan-treated water and fed with 1% (En/L1%), 1.5% (En/L 1.5%) and 2% (En/L 2%) lecithin supplemented feed. The endosulfan in treated water was maintained at the level of 1/40th of LC50 (0.52ppb). At the end of the five weeks, critical temperature maxima (CTmax), lethal temperature maxima (LTmax), critical temperature minima (CTmin) and lethal temperature minima (LTmin) were Determined. There was a significant (Plecithin on temperature tolerance (CTmax, LTmax, CTmin and LTmin) of the groups fed with 1, 1.5 and 2% lecithin-supplemented diet compared to control and endosulfan-exposed groups. Positive correlations were observed between CT max and LTmax (R(2)=0.934) as well as between CTmin and LTmin (R(2)=0.9313). At the end of the thermal tolerance study, endosulfan-induced changes in cellular stress enzymes (Catalase, SOD and GST in liver and gill and neurotansmitter enzyme, brain AChE) were significantly (plecithin. We herein report the role of lecithin in enhancing the thermal tolerance and protection against cellular stress in fish exposed to an organochlorine pesticide. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Skin dose variation: influence of energy

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: This research aimed to quantitatively evaluate the differences in percentage dose of maximum for 6MV and 18MV x-ray beams within the first lcm of interactions. Thus provide quantitative information regarding the basal, dermal and subcutaneous dose differences achievable with these two types of high-energy x-ray beams. Percentage dose of maximum build up curves are measured for most clinical field sizes using 6MV and 18MV x-ray beams. Calculations are performed to produce quantitative results highlighting the percentage dose of maximum differences delivered to various depths within the skin and subcutaneous tissue region by these two beams Results have shown that basal cell layer doses are not significantly different for 6MV and 18Mv x-ray beams At depths beyond the surface and basal cell layer there is a measurable and significant difference in delivered dose. This variation increases to 20% of maximum and 22% of maximum at Imm and 1cm depths respectively. The percentage variations are larger for smaller field sizes where the photon in phantom component of the delivered dose is the most significant contributor to dose By producing graphs or tables of % dose differences in the build up region we can provide quantitative information to the oncologist for consideration (if skin and subcutaneous tissue doses are of importance) during the beam energy selection process for treatment. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  5. Radiation tolerance of the WorldFIP fieldbus interface

    CERN Document Server

    Wijnands, Thijs

    2006-01-01

    This paper summarises on radiation tests on the main components for the WorldFIP fieldbus interface. The chipset based on 0.6 \\mu­m technology has a total dose tolerance of 100 Gy (Co-60) and in standalone mode, no functional interrupts from single events have been observed during proton irradiation (60 MeV). The chipset based on 0.5 \\mu­m technology has a total dose tolerance of 150 Gy (Co-60) but shows a sharp increase in the single event cross section after a dose of 70 Gy. Finally, it was found that the chipset based on 0.5 \\mu­m technology operates reliable in standalone mode in a magnetic field up to 4.6 kGauss.

  6. A systematic methodology review of phase I radiation dose escalation trials

    International Nuclear Information System (INIS)

    Pijls-Johannesma, Madelon; Mastrigt, Ghislaine van; Hahn, Steve M.; De Ruysscher, Dirk; Baumert, Brigitta G.; Lammering, Guido; Buijsen, Jeroen; Bentzen, Soren M.; Lievens, Yolande; Kramar, Andrew; Lambin, Philippe

    2010-01-01

    Background and purpose: The purpose of this review is to evaluate the methodology used in published phase I radiotherapy (RT) dose escalation trials. A specific emphasis was placed on the frequency of reporting late complications as endpoint. Materials and methods: We performed a systematic literature review using a predefined search strategy to identify all phase I trials reporting on external radiotherapy dose escalation in cancer patients. Results: Fifty-three trials (phase I: n = 36, phase I-II: n = 17) fulfilled the inclusion criteria. Of these, 20 used a modified Fibonacci design for the RT dose escalation, but 32 did not specify a design. Late toxicity was variously defined as >3 months (n = 43) or > 6 months (n = 3) after RT, or not defined (n = 7). In only nine studies the maximum tolerated dose (MTD) was related to late toxicity, while only half the studies reported the minimum follow-up period for dose escalation (n = 26). Conclusion: In phase I RT trials, late complications are often not taken into account and there is currently no consensus on the methodology used for radiation dose escalation studies. We therefore propose a decision-tree algorithm which depends on the endpoint selected and whether a validated early surrogate endpoint is available, in order to choose the most appropriate study design.

  7. Pharmacokinetics, Dose Proportionality, and Bioavailability of Bazedoxifene in Healthy Postmenopausal Women.

    Science.gov (United States)

    McKeand, William

    2017-09-01

    Bazedoxifene is a selective estrogen receptor modulator that has estrogen agonist effects on bone and lipid metabolism while having neutral or estrogen antagonist effects on the breast and endometrium. The present report describes findings from 3 Phase I clinical studies that evaluated the single-dose pharmacokinetics (study 1; n = 84), multiple-dose pharmacokinetics (study 2; n = 23), and absolute bioavailability (study 3; n = 18) of bazedoxifene. All 3 studies enrolled healthy postmenopausal women who were either naturally postmenopausal or had undergone bilateral oophorectomy at least 6 months before the start of the study. Study 1 showed that unconjugated and total (unconjugated and conjugated) bazedoxifene levels increased proportionally with ascending oral doses of bazedoxifene (through the dose range of 5-120 mg). Evaluation with or without food intake was conducted at the 10-mg dose, with no clinically relevant effect on pharmacokinetic parameters. Study 2 showed that bazedoxifene achieved steady state in 1 week and exhibited linear pharmacokinetics in doses of 5 to 40 mg with no unexpected accumulation over the dose range. In accordance with a linear pharmacokinetic profile, mean maximum plasma concentration values increased with increasing dose, with values of 1.6, 6.2, and 12.5 ng/mL for the 5-, 20-, and 40-mg doses, respectively. In study 3, tablet and capsule formulations of bazedoxifene formulations had an estimated oral bioavailability of ~6%. The clearance of bazedoxifene was 0.4 (0.1) L/h/kg based on intravenous administration. The oral formulations had comparable exposure profiles with respect to AUC and AUC0-t, and the 90% CIs for these values were within the bioequivalence limits of 80% to 125%. Bazedoxifene was safe and well tolerated in all 3 studies. These pharmacokinetic evaluations in healthy postmenopausal women found that bazedoxifene displayed linear pharmacokinetics with doses ranging from 5 to 40 mg, with no unexpected accumulation

  8. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Froehlich, Georgina; Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor

    2010-01-01

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D min ) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D r ) and urethra (D u ), dose to volume of 2 cm 3 of the rectum (D 2ccm ), and 0.1 cm 3 and 1% of the urethra (D 0.1ccm and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V p ) was 27.1 cm 3 . The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D min was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D 2ccm = 49% for the rectum, D 0.1ccm = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D r , D 2ccm ) = 0.69, R(D u , D 0.1ccm ) = 0.64, R(D u , D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric

  9. Dosimetric evaluation of high-dose-rate interstitial brachytherapy boost treatments for localized prostate cancer.

    Science.gov (United States)

    Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor

    2010-07-01

    To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.

  10. The linear sizes tolerances and fits system modernization

    Science.gov (United States)

    Glukhov, V. I.; Grinevich, V. A.; Shalay, V. V.

    2018-04-01

    The study is carried out on the urgent topic for technical products quality providing in the tolerancing process of the component parts. The aim of the paper is to develop alternatives for improving the system linear sizes tolerances and dimensional fits in the international standard ISO 286-1. The tasks of the work are, firstly, to classify as linear sizes the elements additionally linear coordinating sizes that determine the detail elements location and, secondly, to justify the basic deviation of the tolerance interval for the element's linear size. The geometrical modeling method of real details elements, the analytical and experimental methods are used in the research. It is shown that the linear coordinates are the dimensional basis of the elements linear sizes. To standardize the accuracy of linear coordinating sizes in all accuracy classes, it is sufficient to select in the standardized tolerance system only one tolerance interval with symmetrical deviations: Js for internal dimensional elements (holes) and js for external elements (shafts). The main deviation of this coordinating tolerance is the average zero deviation, which coincides with the nominal value of the coordinating size. Other intervals of the tolerance system are remained for normalizing the accuracy of the elements linear sizes with a fundamental change in the basic deviation of all tolerance intervals is the maximum deviation corresponding to the limit of the element material: EI is the lower tolerance for the of the internal elements (holes) sizes and es is the upper tolerance deviation for the outer elements (shafts) sizes. It is the sizes of the material maximum that are involved in the of the dimensional elements mating of the shafts and holes and determine the fits type.

  11. 78 FR 60715 - Sedaxane; Pesticide Tolerances

    Science.gov (United States)

    2013-10-02

    ... 28-day dermal study did not show systemic toxicity at the limit dose of 1,000 milligrams/kilogram/day... Enforcement Methodology Adequate enforcement methodology is available to enforce the tolerance expression. A...

  12. Field size and dose distribution of electron beam

    International Nuclear Information System (INIS)

    Kang, Wee Saing

    1980-01-01

    The author concerns some relations between the field size and dose distribution of electron beams. The doses of electron beams are measured by either an ion chamber with an electrometer or by film for dosimetry. We analyzes qualitatively some relations; the energy of incident electron beams and depths of maximum dose, field sizes of electron beams and depth of maximum dose, field size and scatter factor, electron energy and scatter factor, collimator shape and scatter factor, electron energy and surface dose, field size and surface dose, field size and central axis depth dose, and field size and practical range. He meets with some results. They are that the field size of electron beam has influence on the depth of maximum dose, scatter factor, surface dose and central axis depth dose, scatter factor depends on the field size and energy of electron beam, and the shape of the collimator, and the depth of maximum dose and the surface dose depend on the energy of electron beam, but the practical range of electron beam is independent of field size

  13. High-Dose Atomoxetine Treatment of ADHD in Youths with Limited Response to Standard Doses

    Science.gov (United States)

    Kratochvil, Christopher J.; Michelson, David; Newcorn, Jeffrey H.; Weiss, Margaret D.; Busner, Joan; Moore, Rodney J.; Ruff, Dustin D.; Ramsey, Janet; Dickson, Ruth; Turgay, Atilla; Saylor, Keith E.; Luber, Stephen; Vaughan, Brigette; Allen, Albert J.

    2007-01-01

    Objective: To assess the utility and tolerability of higher than standard atomoxetine doses to treat attention-deficit/hyperactivity disorder (ADHD). Method: Two randomized, double-blind trials of atomoxetine nonresponders ages 6 to 16 years were conducted comparing continued treatment with same-dose atomoxetine to treatment using greater than…

  14. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    LENUS (Irish Health Repository)

    Bratland, Ase

    2011-04-08

    Abstract Background In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Findings Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. Conclusions When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile. Trial registration ClinicalTrials.gov: NCT00455351

  15. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Bratland, Åse; Dueland, Svein; Hollywood, Donal; Flatmark, Kjersti; Ree, Anne H

    2011-01-01

    In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile.

  16. State of art in radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Choi; Young Soo; Kim, Seong Ho; Cho, Jae Wan; Kim, Chang Hoi; Seo, Young Chil

    2002-02-01

    Working in radiation environment such as nuclear power plant, RI facility, nuclear fuel fabrication facility, medical center has to be considered radiation exposure, and we can implement these job by remote observation and operation. However the camera used for general industry is weakened at radiation, so radiation-tolerant camera is needed for radiation environment. The application of radiation-tolerant camera system is nuclear industry, radio-active medical, aerospace, and so on. Specially nuclear industry, the demand is continuous in the inspection of nuclear boiler, exchange of pellet, inspection of nuclear waste. In the nuclear developed countries have been an effort to develop radiation-tolerant cameras. Now they have many kinds of radiation-tolerant cameras which can tolerate to 10{sup 6}-10{sup 8} rad total dose. In this report, we examine into the state-of-art about radiation-tolerant cameras, and analyze these technology. We want to grow up the concern of developing radiation-tolerant camera by this paper, and upgrade the level of domestic technology.

  17. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  18. Dataset for Phase I randomized clinical trial for safety and tolerability of GET 73 in single and repeated ascending doses including preliminary pharmacokinetic parameters.

    Science.gov (United States)

    Haass-Koffler, Carolina L; Goodyear, Kimberly; Long, Victoria M; Tran, Harrison H; Loche, Antonella; Cacciaglia, Roberto; Swift, Robert M; Leggio, Lorenzo

    2017-12-01

    The data in this article outline the methods used for the administration of GET 73 in the first time-in-human manuscript entitled "Phase I randomized clinical trial for the safety, tolerability and preliminary pharmacokinetics of the mGluR5 negative allosteric modulator GET 73 following single and repeated doses in healthy male volunteers" (Haass-Koffler et al., 2017) [1]. Data sets are provided in two different manners. The first series of tables provided includes procedural information about the experiments conducted. The next series of tables provided includes Pharmacokinetic (PK) parameters for GET 73 and its main metabolite MET 2. This set of data is comprised by two experiments: Experiment 1 references a single ascending dose administration of GET 73 and Experiment 2 references a repeated ascending dose administration of GET 73.

  19. Poor Safety and Tolerability Hamper Reaching a Potentially Therapeutic Dose in the Use of Thalidomide for Alzheimer's Disease: Results from a Double-Blind, Placebo-Controlled Trial.

    Science.gov (United States)

    Decourt, Boris; Drumm-Gurnee, Denise; Wilson, Jeffrey; Jacobson, Sandra; Belden, Christine; Sirrel, Sherye; Ahmadi, Michael; Shill, Holly; Powell, Jessica; Walker, Aaron; Gonzales, Amanda; Macias, Mimi; Sabbagh, Marwan N

    2017-01-01

    To date there is no cure for Alzheimer's disease (AD). After amyloid beta immunotherapies have failed to meet primary endpoints of slowing cognitive decline in AD subjects, the inhibition of the beta-secretase BACE1 appears as a promising therapeutic approach. Pre-clinical data obtained in APP23 mice suggested that the anti-cancer drug thalidomide decreases brainBACE1 and Aβ levels. This prompted us to develop an NIH-supported Phase IIa clinical trial to test the potential of thalidomide for AD. We hypothesized that thalidomide can decrease or stabilize brain amyloid deposits, which would result in slower cognitive decline in drug- versus placebo-treated subjects. This was a 24-week, randomized, double-blind, placebo-controlled, parallel group study with escalating dose regimen of thalidomide with a target dose of 400mg daily in patients with mild to moderate AD. The primary outcome measures were tolerability and cognitive performance assessed by a battery of tests. A total of 185 subjects have been pre-screened, out of which25 were randomized. Mean age of the sample at baseline was 73.64 (±7.20) years; mean education was 14.24 (±2.3) years; mean MMSE score was 21.00 (±5.32); and mean GDS score was 2.76 (±2.28).Among the 25 participants, 14 (56%) terminated early due to adverse events, dramatically decreasing the power of the study. In addition, those who completed the study (44%) never reached the estimated therapeutic dose of 400 mg/day thalidomide because of reported adverse events. The cognitive data showed no difference between the treated and placebo groups at the end of the trial. This study demonstrates AD patients have poor tolerability for thalidomide, and are unable to reach a therapeutic dose felt to be sufficient to have effects on BACE1. Because of poor tolerability, this study failed to demonstrate a beneficial effect on cognition. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  20. Single-dose pharmacokinetics and tolerability of oral delta-9- tetrahydrocannabinol in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Joerger, Markus; Wilkins, Justin; Fagagnini, Stefania; Baldinger, Reto; Brenneisen, Rudolf; Schneider, Ursula; Goldman, Bea; Weber, Markus

    2012-06-01

    Cannabinoids exert neuroprotective and symptomatic effects in amyotrophic lateral sclerosis (ALS). We assessed the pharmacokinetics (PK) and tolerability of delta-9-tetrahydrocannabinol (THC) in ALS patients. Nine patients received THC single oral doses of 5mg and 10mg, separated by a wash-out period of two weeks. Blood samples for the determination of THC, 11-nor-9-carboxy-THC (THC-COOH) and hydroxy-THC (THC-OH) were taken up to 8 hours after intake. Adverse events were assessed by visual analogue scales (VAS). Plasma concentrations of the active metabolite THC-OH were submitted to sequential pharmacokinetic-pharmacodynamic population modeling on individual heart rate as a proxy for THC's cardiovasculatory effects. Drowsiness, euphoria, orthostasis, sleepiness, vertigo and weakness were significantly more frequent in patients receiving 10mg compared to 5 mg THC. A marked interindividual variability was found for the absorption of oral THC (84%) and elimination of THC-COOH (45%). PK data did not support any clinically relevant deviation from linear PK in the investigated range of concentrations. Plasma concentrations of THC-OH were positively correlated with the individual heart rate. An E(max-model) was successfully fitted to individual heart rate, with a THC-OH plasma concentration of 3.2 x 10(-4) μmol/L for EC(50) and an E(max) of 93 bpm for heart rate. The higher 10mg dose of THC was dose-limiting in patients with ALS. High interindividual PK variability requires individuell titration of THC for potential therapeutic use in patients with ALS.

  1. Effectiveness and gastrointestinal tolerability during conversion and titration with once-daily OROS® hydromorphone extended release in opioid-tolerant patients with chronic low back pain

    Directory of Open Access Journals (Sweden)

    Hale ME

    2013-05-01

    Full Text Available Martin E Hale,1 Srinivas R Nalamachu,2 Arif Khan,3 Michael Kutch4,* 1Gold Coast Research, LLC, Weston, FL, USA; 2International Clinical Research Institute, Overland Park, KS, USA; 3MedNorthwest Clinical Research Center, Bellevue, WA, USA; Duke University Medical Center, Durham, NC, USA; 4Applied Clinical Intelligence, LLC, Bala Cynwyd, PA, USA *Affiliation at the time this work was completed. Michael Kutch is currently affiliated with Cytel Inc, Chesterbrook, PA, USA Purpose: To describe the efficacy and safety of hydromorphone extended-release tablets (OROS hydromorphone ER during dose conversion and titration. Patients and methods: A total of 459 opioid-tolerant adults with chronic moderate to severe low back pain participated in an open-label, 2- to 4-week conversion/titration phase of a double-blind, placebo-controlled, randomized withdrawal trial, conducted at 70 centers in the United States. Patients were converted to once-daily OROS hydromorphone ER at 75% of the equianalgesic dose of their prior total daily opioid dose (5:1 conversion ratio, and titrated as frequently as every 3 days to a maximum dose of 64 mg/day. The primary outcome measure was change in pain intensity numeric rating scale; additional assessments included the Patient Global Assessment and the Roland–Morris Disability Questionnaire scores. Safety assessments were performed at each visit and consisted of recording and monitoring all adverse events (AEs and serious AEs. Results: Mean (standard deviation final daily dose of OROS hydromorphone ER was 37.5 (17.8 mg. Mean (standard error of the mean [SEM] numeric rating scale scores decreased from 6.6 (0.1 at screening to 4.3 (0.1 at the final titration visit (mean [SEM] change, -2.3 [0.1], representing a 34.8% reduction. Mean (SEM change in Patient Global Assessment was -0.6 (0.1, and mean change (SEM in the Roland–Morris Disability Questionnaire was -2.8 (0.3. Patients achieving a stable dose showed greater improvement

  2. New approach for food allergy management using low-dose oral food challenges and low-dose oral immunotherapies.

    Science.gov (United States)

    Yanagida, Noriyuki; Okada, Yu; Sato, Sakura; Ebisawa, Motohiro

    2016-04-01

    A number of studies have suggested that a large subset of children (approximately 70%) who react to unheated milk or egg can tolerate extensively heated forms of these foods. A diet that includes baked milk or egg is well tolerated and appears to accelerate the development of regular milk or egg tolerance when compared with strict avoidance. However, the indications for an oral food challenge (OFC) using baked products are limited for patients with high specific IgE values or large skin prick test diameters. Oral immunotherapies (OITs) are becoming increasingly popular for the management of food allergies. However, the reported efficacy of OIT is not satisfactory, given the high frequency of symptoms and requirement for long-term therapy. With food allergies, removing the need to eliminate a food that could be consumed in low doses could significantly improve quality of life. This review discusses the importance of an OFC and OIT that use low doses of causative foods as the target volumes. Utilizing an OFC or OIT with a low dose as the target volume could be a novel approach for accelerating the tolerance to causative foods. Copyright © 2015 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  3. 78 FR 46267 - Trifluralin; Pesticide Tolerance

    Science.gov (United States)

    2013-07-31

    ...), trifluralin was tested up to the limit dose (1000 mg/kg/day) and caused no systemic toxicity. Handler exposure... detection (ECD)) is available to enforce the tolerance expression. The method may be requested from: Chief...

  4. SU-E-T-348: Effect of Treatment Table and Immobilization Devices On Surface Dose When Using a GRID Technique

    Energy Technology Data Exchange (ETDEWEB)

    Gajdos, S; Donaghue, J [Akron General Medical Center, Akron, OH (United States)

    2015-06-15

    Purpose: To determine the increase of surface dose of MLC-designed GRID therapy in the presence of immobilization devices and treatment table. Methods: To create a GRID field, our facility utilizes an MLC consisting of four millimeter wide leaves. The field is designed to have aperture sizes of 0.8 cm X 0.8 cm with inter-aperture distance of 3.2 cm. Gafchromic EBT3 film was placed between the surface of a solid water phantom and the immobilization device. The treatment table was also present within the beam path. The devices consist of carbon fiber exterior shell. A piece of film was also placed at maximal depth for the photon energy of 10 MV. Image files were converted to dose per a calibration curve based on the selected red channel. The surface dose to maximum dose was established by comparing the ratio of seven centrally located aperture regions-of-interest and four adjacent inter-aperture regions-of-interest were measured with the available software tools. Results: With no devices present in beam path, the ratio of surface dose to maximum dose was 11.5% ± 0.3% for aperture region and 7.0% ± 0.1% for inter-aperture region. When devices are present, the ratio of surface dose to maximum dose was 45.2% ± 0.5% and 33.8% ± 1.1%, respectively. Due to the presence of devices, the surface dose increases in aperture region by 3.8 times or in the inter-aperture region by 4.7 times. Conclusion: The purpose of using GRID technique is to deliver a single fractional dose in range of 15–20 Gy to a bulky lesion while also preserving skin tolerance. The increase of surface dose due to devices placed in beam path may increase the chance of skin toxicity in GRID therapy. Care should be used to determine best manageable patient immobilization while considering skin dose especially for posteriorly located lesions.

  5. Phase I dose escalation pharmacokinetic assessment of intravenous humanized anti-MUC1 antibody AS1402 in patients with advanced breast cancer.

    Science.gov (United States)

    Pegram, Mark D; Borges, Virginia F; Ibrahim, Nuhad; Fuloria, Jyotsna; Shapiro, Charles; Perez, Susan; Wang, Karen; Schaedli Stark, Franziska; Courtenay Luck, Nigel

    2009-01-01

    . Repeated iv administration of AS1402 was well tolerated, with a maximum tolerated dose (MTD) exceeding 16 mg/kg, the highest dose administered in this study. The half-life and exposure of AS1402 were such that weekly dosing could achieve plasma concentrations corresponding to the maximal ADCC activity observed in vitro. A phase II study is ongoing to evaluate the clinical activity of AS1402 in patients with advanced breast cancer. ClinicalTrials.gov Identifier: NCT00096057.

  6. Inducing rat brain CYP2D with nicotine increases the rate of codeine tolerance; predicting the rate of tolerance from acute analgesic response.

    Science.gov (United States)

    McMillan, Douglas M; Tyndale, Rachel F

    2017-12-01

    Repeated opioid administration produces analgesic tolerance, which may lead to dose escalation. Brain CYP2D metabolizes codeine to morphine, a bioactivation step required for codeine analgesia. Higher brain, but not liver, CYP2D is found in smokers and nicotine induces rat brain, but not liver, CYP2D expression and activity. Nicotine induction of rat brain CYP2D increases acute codeine conversion to morphine, and analgesia, however the role of brain CYP2D on the effects of repeated codeine exposure and tolerance is unknown. Rats were pretreated with nicotine (brain CYP2D inducer; 1mg/kg subcutaneously) or vehicle (saline; 1ml/kg subcutaneously). Codeine (40-60mg/kg oral-gavage) or morphine (20-30mg/kg oral-gavage) was administered daily and analgesia was assessed daily using the tail-flick reflex assay. Nicotine (versus saline) pretreatment increased acute codeine analgesia (1.32-fold change in AUC 0-60 min ; pnicotine did not alter acute morphine analgesia (1.03-fold; p>0.8), or the rate of morphine tolerance (8.1%/day versus 7.6%; p>0.9). The rate of both codeine and morphine tolerance (loss in peak analgesia from day 1 to day 4) correlated with initial analgesic response on day 1 (R=0.97, p<001). Increasing brain CYP2D altered initial analgesia and subsequent rate of tolerance. Variation in an individual's initial response to analgesic (e.g. high initial dose, smoking) may affect the rate of tolerance, and thereby the risk for dose escalation and/or opioid dependence. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Dose-volume based ranking of incident beam direction and its utility in facilitating IMRT beam placement

    International Nuclear Information System (INIS)

    Schreibmann, Eduard; Xing Lei

    2005-01-01

    Purpose: Beam orientation optimization in intensity-modulated radiation therapy (IMRT) is computationally intensive, and various single beam ranking techniques have been proposed to reduce the search space. Up to this point, none of the existing ranking techniques considers the clinically important dose-volume effects of the involved structures, which may lead to clinically irrelevant angular ranking. The purpose of this work is to develop a clinically sensible angular ranking model with incorporation of dose-volume effects and to show its utility for IMRT beam placement. Methods and Materials: The general consideration in constructing this angular ranking function is that a beamlet/beam is preferable if it can deliver a higher dose to the target without exceeding the tolerance of the sensitive structures located on the path of the beamlet/beam. In the previously proposed dose-based approach, the beamlets are treated independently and, to compute the maximally deliverable dose to the target volume, the intensity of each beamlet is pushed to its maximum intensity without considering the values of other beamlets. When volumetric structures are involved, the complication arises from the fact that there are numerous dose distributions corresponding to the same dose-volume tolerance. In this situation, the beamlets are not independent and an optimization algorithm is required to find the intensity profile that delivers the maximum target dose while satisfying the volumetric constraints. In this study, the behavior of a volumetric organ was modeled by using the equivalent uniform dose (EUD). A constrained sequential quadratic programming algorithm (CFSQP) was used to find the beam profile that delivers the maximum dose to the target volume without violating the EUD constraint or constraints. To assess the utility of the proposed technique, we planned a head-and-neck and abdominal case with and without the guidance of the angular ranking information. The qualities of the

  8. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline.

    Science.gov (United States)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören; Nordvall, S Lennart; Pedroletti, Christophe; Bengtsson, Thomas; Johannes-Hellberg, Ingegerd; Rosenborg, Johan

    2004-10-01

    To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis) 4.5 microg (F4.5) or terbutaline (Bricanyl) 500 microg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. Formoterol and terbutaline had significant beta2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration and PR interval, the systemic effects were significantly more pronounced with terbutaline than with formoterol. Thus, mean minimum plasma potassium, was suppressed from 3.56 (95% confidence interval, CI: 3.48-3.65) mmol l(-1) on the day of no treatment to 2.98 (CI: 2.90-3.08) after 10 x F4.5 and 2.70 (CI: 2.61-2.78) mmol l(-1) after 10 x T500, and maximum Q-Tc (heart rate corrected Q-T interval [Bazett's formula]) was prolonged from 429 (CI: 422-435) ms on the day of no treatment, to 455 (CI: 448-462) ms after 10 x F4.5 and 470 (CI: 463-476) ms after 10 x T500. Estimates of relative dose potency indicated that F4.5 microg had the same systemic activity as the clinically less effective dose of 250 microg terbutaline. The duration of systemic effects differed marginally between treatments. Spontaneously reported adverse events (most frequently tremor) were fewer with formoterol (78% of the children) than with terbutaline (95%). A serious adverse event occurred after inhalation of 45 microg formoterol over the 1 h dosing time, that prompted the extension of dosing time to 2.5 h. Multiple inhalations over 2.5 h of

  9. Phase I trial of split-dose induction docetaxel, cisplatin, and 5-fluorouracil (TPF chemotherapy followed by curative surgery combined with postoperative radiotherapy in patients with locally advanced oral and oropharyngeal squamous cell cancer (TISOC-1

    Directory of Open Access Journals (Sweden)

    Oertel Katrin

    2012-10-01

    Full Text Available Abstract Background Induction chemotherapy (ICT with docetaxel, cisplatin and fluorouracil (TPF followed by radiotherapy is an effective treatment option for unresectable locally advanced head and neck cancer. This phase I study was designed to investigate the safety and tolerability of a split-dose TPF ICT regimen prior to surgery for locally advanced resectable oral and oropharyngeal cancer. Methods Patients received TPF split on two dosages on day 1 and 8 per cycle for one or three 3-week cycles prior to surgery and postoperative radiotherapy or radiochemotherapy. Docetaxel was escalated in two dose levels, 40 mg/m2 (DL 0 and 30 mg/m2 (DL −1, plus 40 mg/m2 cisplatin and 2000 mg/m2 fluorouracil per week using a 3 +3 dose escalation algorithm. Results Eighteen patients were enrolled and were eligible for toxicity and response. A maximum tolerated dose of 30 mg/m2 docetaxel per week was reached. The most common grade 3+ adverse event was neutropenia during ICT in 10 patients. Surgery reached R0 resection in all cases. Nine patients (50% showed complete pathologic regression. Conclusions A split-dose regime of TPF prior to surgery is feasible, tolerated and merits additional investigation in a phase II study with a dose of 30 mg/m docetaxel per week. Trial registration number NCT01108042 (ClinicalTrials.gov Identifier

  10. Comparsion of maximum viscosity and viscometric method for identification of irradiated sweet potato starch

    International Nuclear Information System (INIS)

    Yi, Sang Duk; Yang, Jae Seung

    2000-01-01

    A study was carried out to compare viscosity and maximum viscosity methods for the detection of irradiated sweet potato starch. The viscosity of all samples decreased by increasing stirring speeds and irradiation doses. This trend was similar for maximum viscosity. Regression coefficients and expressions of viscosity and maximum viscosity with increasing irradiation dose were 0.9823 (y=335.02e -0. 3 366x ) at 120 rpm and 0.9939 (y =-42.544x+730.26). This trend in viscosity was similar for all stirring speeds. Parameter A, B and C values showed a dose dependent relation and were a better parameter for detecting irradiation treatment than maximum viscosity and the viscosity value it self. These results suggest that the detection of irradiated sweet potato starch is possible by both the viscometric and maximum visosity method. Therefore, the authors think that the maximum viscosity method can be proposed as one of the new methods to detect the irradiation treatment for sweet potato starch

  11. Plant Distribution Data Show Broader Climatic Limits than Expert-Based Climatic Tolerance Estimates.

    Directory of Open Access Journals (Sweden)

    Caroline A Curtis

    Full Text Available Although increasingly sophisticated environmental measures are being applied to species distributions models, the focus remains on using climatic data to provide estimates of habitat suitability. Climatic tolerance estimates based on expert knowledge are available for a wide range of plants via the USDA PLANTS database. We aim to test how climatic tolerance inferred from plant distribution records relates to tolerance estimated by experts. Further, we use this information to identify circumstances when species distributions are more likely to approximate climatic tolerance.We compiled expert knowledge estimates of minimum and maximum precipitation and minimum temperature tolerance for over 1800 conservation plant species from the 'plant characteristics' information in the USDA PLANTS database. We derived climatic tolerance from distribution data downloaded from the Global Biodiversity and Information Facility (GBIF and corresponding climate from WorldClim. We compared expert-derived climatic tolerance to empirical estimates to find the difference between their inferred climate niches (ΔCN, and tested whether ΔCN was influenced by growth form or range size.Climate niches calculated from distribution data were significantly broader than expert-based tolerance estimates (Mann-Whitney p values << 0.001. The average plant could tolerate 24 mm lower minimum precipitation, 14 mm higher maximum precipitation, and 7° C lower minimum temperatures based on distribution data relative to expert-based tolerance estimates. Species with larger ranges had greater ΔCN for minimum precipitation and minimum temperature. For maximum precipitation and minimum temperature, forbs and grasses tended to have larger ΔCN while grasses and trees had larger ΔCN for minimum precipitation.Our results show that distribution data are consistently broader than USDA PLANTS experts' knowledge and likely provide more robust estimates of climatic tolerance, especially for

  12. Effectiveness and tolerability of fixed-dose combination enalapril plus nitrendipine in hypertensive patients: results of the 3-month observational, post-marketing, multicentre, prospective CENIT study.

    Science.gov (United States)

    Sierra, Alejandro de la; Roca-Cusachs, Alejandro; Redón, Josep; Marín, Rafael; Luque, Manuel; Figuera, Mariano de la; Garcia-Garcia, Margarida; Falkon, Liliana

    2009-01-01

    Monotherapy with any class of antihypertensive drug effectively controls blood pressure (BP) in only about 50% of patients. Consequently, the majority of patients with hypertension require combined therapy with two or more medications. This study aimed to evaluate the effectiveness (systolic BP [SBP]/diastolic BP [DBP] control) and tolerability of the fixed-dose combination enalapril/nitrendipine 10 mg/20 mg administered as a single daily dose in hypertensive patients. This was a post-authorization, multicentre, prospective, observational study conducted in primary care with a 3-month follow-up. Patients throughout Spain with uncontrolled hypertension (> or =140/90 mmHg for patients without diabetes mellitus, or > or =130/85 mmHg for patients with diabetes) on monotherapy or with any combination other than enalapril + nitrendipine, or who were unable to tolerate their previous antihypertensive therapy, were recruited. Change from previous to study treatment was according to usual clinical practice. BP was measured once after 5 minutes of rest in the sitting position. Therapeutic response was defined as follows: 'controlled' meant controlled BP ( or =20 mmHg and in DBP of > or =10 mmHg. The main laboratory test parameters were documented at baseline and after 3 months. Patients aged >65 years, with diabetes, with isolated systolic hypertension (ISH; SBP > or =140 mmHg for patients without diabetes, SBP > or =130 mmHg for patients with diabetes) and who were obese (body mass index [BMI] > or =30 kg/m2) were analysed separately. Of 6537 patients included, 5010 and 6354 patients were assessed in effectiveness and tolerability analyses, respectively. In the tolerability analysis population, there were 3023 men (47.6%) and 3321 women (52.4%). The mean (+/- SD) age of the tolerability analysis group was 62.8 (+/- 10.7) years. A total of 71.1% of the patients presented at least one clinical cardiovascular risk factor other than hypertension, with the most frequent being

  13. Single- and multiple-dose pharmacokinetics, pharmacodynamics, and safety of apixaban in healthy Chinese subjects

    Directory of Open Access Journals (Sweden)

    Cui Y

    2013-12-01

    Full Text Available Yimin Cui,1 Yan Song,2 Jessie Wang,2 Zhigang Yu,2 Alan Schuster,2 Yu Chen Barrett,2 Charles Frost2 1Peking University First Hospital, Beijing, People's Republic of China; 2Bristol-Myers Squibb, Princeton, NJ, USA Background: The pharmacokinetics (PK, pharmacodynamics (PD, and safety of apixaban were assessed in healthy Chinese subjects in this randomized, placebo-controlled, double-blind, single-sequence, single- and multiple-dose study. Subjects and methods: Eighteen subjects 18–45 years of age were randomly assigned (2:1 ratio to receive apixaban or matched placebo. Subjects received a single 10 mg dose of apixaban or placebo on day 1, followed by 10 mg apixaban or placebo twice daily for 6 days (days 4–9. The PK and PD of apixaban were assessed by collecting plasma samples for 72 hours following the dose on day 1 and the morning dose on day 9, and measuring apixaban concentration and anti-Xa activity. Safety was assessed via physical examinations, vital sign measurements, electrocardiograms, and clinical laboratory evaluations. Results: PK analysis showed similar characteristics of apixaban after single and multiple doses, including a median time to maximum concentration of ~3 hours, mean elimination half-life of ~11 hours, and renal clearance of ~1.2 L/hour. The accumulation index was 1.7, consistent with twice-daily dosing and the observed elimination half-life. Single-dose data predict multiple-dose PK, therefore apixaban PK are time-independent. The relationship between anti-Xa activity and plasma apixaban concentrations appears to be linear. Apixaban was safe and well tolerated, with no bleeding-related adverse events reported. Conclusion: Apixaban was safe and well tolerated in healthy Chinese subjects. Apixaban PK and PD were predictable and consistent with findings from previous studies in Asian and non-Asian subjects. The administration of apixaban does not require any dose modification based on race. Keywords: apixaban, oral

  14. Radiation tolerance of NPN bipolar technology with 30 GHz Ft

    International Nuclear Information System (INIS)

    Flament, O.; Synold, S.; Pontcharra, J. de; Niel, S.

    1999-01-01

    The ionizing dose and neutron radiation tolerance of Si QSA bipolar technology has been investigated. The transistors exhibit good radiation tolerance up to 100 krad and 5 10 13 n/cm 2 without any special fabrication steps to harden the technology to the studied effects. (authors)

  15. Dual specific oral tolerance induction using interferon gamma for IgE-mediated anaphylactic food allergy and the dissociation of local skin allergy and systemic oral allergy: tolerance or desensitization?

    Science.gov (United States)

    Noh, G; Jang, E H

    2014-01-01

    Specific oral tolerance induction (SOTI) for IgE-mediated food allergy (IFA) can be successfully achieved using interfero gamma (classic SOTI). In this study, a tolerable dose was introduced during tolerance induction with interferon gamma (dual SOTI), and its effectiveness was evaluated. The study population comprised 25 IFA patients. Blood samples were taken for analysis, including complete blood count with differential counts of eosinophils, serum total IgE levels, and specific IgE for allergenic foods. Skin prick tests were conducted with the allergens. Oral food challenges were performed to diagnose IFA. Ten patients received dual SOTI, 5 received classic SOTI, 5 received SOTI without interferon gamma (original SOTI), and 5 were not treated (controls). Patients treated with dual SOTI and classic SOTI using interferon gamma became tolerant to the allergenic food. The tolerable dose was introduced successfully in dual SOTI. It was difficult to proceed with the same dosing protocol used for classic SOTI in cases treated with original SOTI. Following dual SOTI, the systemic reaction to oral intake subsided, but the local skin reaction to contact with the allergenic food persisted. Dual SOTI is an improved protocol for SOTI using interferon gamma for IFA.The local skin reaction and systemic reaction to oral intake were dissociated following dual SOTI. In cases of food allergy, tolerance appears to result from desensitization to allergens.

  16. Role of adenosine receptors in caffeine tolerance

    International Nuclear Information System (INIS)

    Holtzman, S.G.; Mante, S.; Minneman, K.P.

    1991-01-01

    Caffeine is a competitive antagonist at adenosine receptors. Receptor up-regulation during chronic drug treatment has been proposed to be the mechanism of tolerance to the behavioral stimulant effects of caffeine. This study reassessed the role of adenosine receptors in caffeine tolerance. Separate groups of rats were given scheduled access to drinking bottles containing plain tap water or a 0.1% solution of caffeine. Daily drug intake averaged 60-75 mg/kg and resulted in complete tolerance to caffeine-induced stimulation of locomotor activity, which could not be surmounted by increasing the dose of caffeine. 5'-N-ethylcarboxamidoadenosine (0.001-1.0 mg/kg) dose dependently decreased the locomotor activity of caffeine-tolerant rats and their water-treated controls but was 8-fold more potent in the latter group. Caffeine (1.0-10 mg/kg) injected concurrently with 5-N-ethylcarboxamidoadenosine antagonized the decreases in locomotor activity comparably in both groups. Apparent pA2 values for tolerant and control rats also were comparable: 5.05 and 5.11. Thus, the adenosine-antagonist activity of caffeine was undiminished in tolerant rats. The effects of chronic caffeine administration on parameters of adenosine receptor binding and function were measured in cerebral cortex. There were no differences between brain tissue from control and caffeine-treated rats in number and affinity of adenosine binding sites or in receptor-mediated increases (A2 adenosine receptor) and decreases (A1 adenosine receptor) in cAMP accumulation. These results are consistent with theoretical arguments that changes in receptor density should not affect the potency of a competitive antagonist. Experimental evidence and theoretical considerations indicate that up-regulation of adenosine receptors is not the mechanism of tolerance to caffeine-induced stimulation of locomotor activity

  17. Role of adenosine receptors in caffeine tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Holtzman, S.G.; Mante, S.; Minneman, K.P. (Emory Univ. School of Medicine, Atlanta, GA (USA))

    1991-01-01

    Caffeine is a competitive antagonist at adenosine receptors. Receptor up-regulation during chronic drug treatment has been proposed to be the mechanism of tolerance to the behavioral stimulant effects of caffeine. This study reassessed the role of adenosine receptors in caffeine tolerance. Separate groups of rats were given scheduled access to drinking bottles containing plain tap water or a 0.1% solution of caffeine. Daily drug intake averaged 60-75 mg/kg and resulted in complete tolerance to caffeine-induced stimulation of locomotor activity, which could not be surmounted by increasing the dose of caffeine. 5'-N-ethylcarboxamidoadenosine (0.001-1.0 mg/kg) dose dependently decreased the locomotor activity of caffeine-tolerant rats and their water-treated controls but was 8-fold more potent in the latter group. Caffeine (1.0-10 mg/kg) injected concurrently with 5-N-ethylcarboxamidoadenosine antagonized the decreases in locomotor activity comparably in both groups. Apparent pA2 values for tolerant and control rats also were comparable: 5.05 and 5.11. Thus, the adenosine-antagonist activity of caffeine was undiminished in tolerant rats. The effects of chronic caffeine administration on parameters of adenosine receptor binding and function were measured in cerebral cortex. There were no differences between brain tissue from control and caffeine-treated rats in number and affinity of adenosine binding sites or in receptor-mediated increases (A2 adenosine receptor) and decreases (A1 adenosine receptor) in cAMP accumulation. These results are consistent with theoretical arguments that changes in receptor density should not affect the potency of a competitive antagonist. Experimental evidence and theoretical considerations indicate that up-regulation of adenosine receptors is not the mechanism of tolerance to caffeine-induced stimulation of locomotor activity.

  18. Spinal Cord Tolerance to Reirradiation With Single-Fraction Radiosurgery: A Swine Model

    Energy Technology Data Exchange (ETDEWEB)

    Medin, Paul M., E-mail: Paul.medin@utsouthwestern.edu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Foster, Ryan D. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Kogel, Albert J. van der [Department of Radiation Oncology, Radboud University Medical Center Nijmegen, Nijmegen (Netherlands); Sayre, James W. [Department of Biostatistics and Radiology, University of California Los Angeles, Los Angeles, California (United States); McBride, William H. [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Solberg, Timothy D. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2012-07-01

    Purpose: This study was performed to determine swine spinal cord tolerance to single-fraction, partial-volume irradiation 1 year after receiving uniform irradiation to 30 Gy in 10 fractions. Methods and Materials: A 10-cm length of spinal cord (C3-T1) was uniformly irradiated to 30 Gy in 10 consecutive fractions and reirradiated 1 year later with a single radiosurgery dose centered within the previously irradiated segment. Radiosurgery was delivered to a cylindrical volume approximately 5 cm in length and 2 cm in diameter, which was positioned laterally to the cervical spinal cord, resulting in a dose distribution with the 90%, 50%, and 10% isodose lines traversing the ipsilateral, central, and contralateral spinal cord, respectively. Twenty-three pigs were stratified into six dose groups with mean maximum spinal cord doses of 14.9 {+-} 0.1 Gy (n = 2), 17.1 {+-} 0.3 Gy (n = 3), 19.0 {+-} 0.1 Gy (n = 5), 21.2 {+-} 0.1 Gy (n = 5), 23.4 {+-} 0.2 Gy (n = 5), and 25.4 {+-} 0.4 Gy (n = 3). The mean percentage of spinal cord volumes receiving {>=}10 Gy for the same groups were 34% {+-} 1%, 40% {+-} 1%, 46% {+-} 3%, 52% {+-} 1%, 56 {+-} 3%, and 57% {+-} 1%. The study endpoint was motor neurologic deficit as determined by a change in gait during a 1- year follow-up period. Results: A steep dose-response curve was observed with a 50% incidence of paralysis (ED{sub 50}) for the maximum point dose of 19.7 Gy (95% confidence interval, 17.4-21.4). With two exceptions, histology was unremarkable in animals with normal neurologic status, while all animals with motor deficits showed some degree of demyelination and focal white matter necrosis on the irradiated side, with relative sparing of gray matter. Histologic comparison with a companion study of de novo irradiated animals revealed that retreatment responders had more extensive tissue damage, including infarction of gray matter, only at prescription doses >20 Gy. Conclusion: Pigs receiving spinal radiosurgery 1 year after

  19. BAYESIAN DATA AUGMENTATION DOSE FINDING WITH CONTINUAL REASSESSMENT METHOD AND DELAYED TOXICITY

    Science.gov (United States)

    Liu, Suyu; Yin, Guosheng; Yuan, Ying

    2014-01-01

    A major practical impediment when implementing adaptive dose-finding designs is that the toxicity outcome used by the decision rules may not be observed shortly after the initiation of the treatment. To address this issue, we propose the data augmentation continual re-assessment method (DA-CRM) for dose finding. By naturally treating the unobserved toxicities as missing data, we show that such missing data are nonignorable in the sense that the missingness depends on the unobserved outcomes. The Bayesian data augmentation approach is used to sample both the missing data and model parameters from their posterior full conditional distributions. We evaluate the performance of the DA-CRM through extensive simulation studies, and also compare it with other existing methods. The results show that the proposed design satisfactorily resolves the issues related to late-onset toxicities and possesses desirable operating characteristics: treating patients more safely, and also selecting the maximum tolerated dose with a higher probability. The new DA-CRM is illustrated with two phase I cancer clinical trials. PMID:24707327

  20. Critical Dose of Internal Organs Internal Exposure - 13471

    Energy Technology Data Exchange (ETDEWEB)

    Grigoryan, G.; Amirjanyan, A. [Nuclear and Radiation Safety Centre (Armenia); Grigoryan, N. [Yerevan State Medical University 4Tigran Mets,375010 Yerevan (Armenia)

    2013-07-01

    The health threat posed by radionuclides has stimulated increased efforts to developed characterization on the biological behavior of radionuclides in humans in all ages. In an effort motivated largely by the Chernobyl nuclear accident, the International Commission on Radiological Protection (ICRP) is assembling a set of age specific biokinetic models for environmentally important radioelements. Radioactive substances in the air, mainly through the respiratory system and digestive tract, is inside the body. Radioactive substances are unevenly distributed in various organs and tissues. Therefore, the degree of damage will depend not only on the dose of radiation have but also on the critical organ, which is the most accumulation of radioactive substances, which leads to the defeat of the entire human body. The main objective of radiation protection, to avoid exceeding the maximum permissible doses of external and internal exposure of a person to prevent the physical and genetic damage people. The maximum tolerated dose (MTD) of radiation is called a dose of radiation a person in uniform getting her for 50 years does not cause changes in the health of the exposed individual and his progeny. The following classification of critical organs, depending on the category of exposure on their degree of sensitivity to radiation: First group: the whole body, gonads and red bone marrow; Second group: muscle, fat, liver, kidney, spleen, gastrointestinal tract, lungs and lens of the eye; The third group: bone, thyroid and skin; Fourth group: the hands, forearms, feet. MTD exposure whole body, gonads and bone marrow represent the maximum exposures (5 rem per year) experienced by people in their normal activities. The purpose of this article is intended dose received from various internal organs of the radionuclides that may enter the body by inhalation, and gastrointestinal tract. The biokinetic model describes the time dependent distribution and excretion of different

  1. B cells in operational tolerance.

    Science.gov (United States)

    Chesneau, M; Danger, R; Soulillou, J-P; Brouard, S

    2018-02-16

    Transplantation is currently the therapy of choice for endstage organ failure even though it requires long-term immunosuppresive therapy, with its numerous side effects, for acceptance of the transplanted organ. In rare cases however, patients develop operational tolerance, that is, graft survival without immunosuppression. Studies conducted on these patients reveal genetic, phenotypic, and functional signatures. They provide a better understanding of the immunological mechanisms involved in operational tolerance and define biomarkers that could be used to adapt immunosuppressive treatment to the individual, safely reduce immunosuppression doses, and ideally and safely guide immunosuppression withdrawal. This review summarizes studies that suggest a role for B cells as biomarkers of operational tolerance and discusses the use of B cells as a predictive tool for immunologic risk. Copyright © 2018. Published by Elsevier Inc.

  2. Morphine tolerance offers protection from radiogenic performance deficits

    International Nuclear Information System (INIS)

    Mickley, G.A.; Stevens, K.E.; Burrows, J.M.; White, G.A.; Gibbs, G.L.

    1983-01-01

    When rats are exposed to a sufficiently large dose of ionizing radiation they exhibit lethargy, hypokinesia, and deficits in performance. These and other behavioral changes parallel those often observed in this species after a large dose of morphine. Since the release of endogenous opiates has been implicated in some stress reactions, we sought to determine if they might play a part in radiogenic behavioral deficits. Rats were trained to criterion on a signaled avoidance task. Some subjects were then implanted with a pellet containing 75 mg of morphine. Other animals received placebo implants. Over a number of days, morphine tolerance was evaluated by measurement of body temperature changes. Prior to 2500 rad 60 Co exposure or sham irradiation, morphine (or placebo) pellets were removed. Twenty-four hours later rats were retested to assess their performance on the avoidance task. Morphine-tolerant subjects performed significantly better than the irradiated placebo-implanted group and no differently than morphine-tolerant/sham-irradiated animals. Morphine tolerance seems to provide a degree of behavioral radiation resistance. These data are consistent with the hypothesis that endogenous opiate hyperexcretion may play some part in the behavioral deficits often observed after irradiation

  3. Improvement of CMOS VLSI rad tolerance by processing technics

    International Nuclear Information System (INIS)

    Guyomard, D.; Desoutter, I.

    1986-01-01

    The following study concerns the development of integrated circuits for fields requiring only relatively low radiation tolerance levels, and especially for the civil spatial district area. Process modifications constitute our basic study. They have been carried into effects. Our work and main results are reported in this paper. Well known 2.5 and 3 μm CMOS technologies are under our concern. A first set of modifications enables us to double the cumulative dose tolerance of a 4 Kbit SRAM, keeping at the same time the same kind of damage. We obtain memories which tolerate radiation doses as high as 16 KRad(Si). Repetitivity of the results, linked to the quality assurance of this specific circuit, is reported here. A second set of modifications concerns the processing of gate array. In particular, the choice of the silicon substrate type, (epitaxy substrate), is under investigation. On the other hand, a complete study of a test vehicule allows us to accurately measure the rad tolerance of various components of the Cell library [fr

  4. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6–11 years-old than cumulative high doses of inhaled terbutaline

    Science.gov (United States)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören; Nordvall, S Lennart; Pedroletti, Christophe; Bengtsson, Thomas; Johannes-Hellberg, Ingegerd; Rosenborg, Johan

    2004-01-01

    Objectives To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. Methods Twenty boys and girls (6–11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis®) 4.5 µg (F4.5) or terbutaline (Bricanyl®) 500 µg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler®) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. Results Formoterol and terbutaline had significant β2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration and PR interval, the systemic effects were significantly more pronounced with terbutaline than with formoterol. Thus, mean minimum plasma potassium, was suppressed from 3.56 (95% confidence interval, CI: 3.48–3.65) mmol l−1 on the day of no treatment to 2.98 (CI: 2.90–3.08) after 10 × F4.5 and 2.70 (CI: 2.61–2.78) mmol l−1 after 10 × T500, and maximum Q-Tc (heart rate corrected Q-T interval [Bazett's formula]) was prolonged from 429 (CI: 422–435) ms on the day of no treatment, to 455 (CI: 448–462) ms after 10 × F4.5 and 470 (CI: 463–476) ms after 10 × T500. Estimates of relative dose potency indicated that F4.5 µg had the same systemic activity as the clinically less effective dose of 250 µg terbutaline. The duration of systemic effects differed marginally between treatments. Spontaneously reported adverse events (most frequently tremor) were fewer with formoterol (78% of the children) than with terbutaline (95%). A serious adverse event occurred after inhalation of 45 µg formoterol over the 1 h dosing time, that prompted the extension of dosing time to 2.5 h

  5. Tolerance of retroperitoneal structures to intraoperative radiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.; Terrill, R.

    1982-01-01

    In conjunction with the clinical development of intraoperative radiotherapy, a study was undertaken in dogs to define the tolerance of normal anatomic structures in the retroperitoneum to radiation delivered during operation. Twenty adult dogs were subjected to laparotomy and intraoperative 11 MeV electron irradiation in single doses ranging from 0.to 5000 rad. Animals were followed regularly with clinical observation, blood count, serum chemistries, pyelography, and angiography. Animals were sacrificed and autopsied at regular intervals up to 12 months following treatment to assess radiation-induced complications or tissue damage. Irradiation field in all dogs consisted of a 4 X 15 cm rectangle extending in the retroperitoneum from the level of the renal vessels to the bifurcation of aorta and vena cava. The field included aorta, vena cava, inferior portion of left kidney, and distal portion of left ureter. No complications or histologic changes occurred in any animal given doses of 2000 rad, with a follow-up in excess of 18 months. A dose of 3000 rad was well tolerated, except for left ureteral occlusion in one animal. Mild vascular fibrosis was present inthe aorta and vena cava, and significant ureteral fibrosis developed by six months after doses of 4000 or 5000 rad. All animals that received 5000 rad died of radiation-related complications, including ureteral obstruction and rectal perforation. It was concluded that major vessels tolerate intraoperative irradiation well up to and including 3000 rad and that no clinically significant vascular problems develop after 4000 and 5000 rad, although some fibrosis does occur. The ureter and kidney appear to be the most radiosensitive structures inthe retroperitoneum, showing progressive changes at 300 rad or greater and showing the potential for serious complications after doses of 4000 rad or more

  6. Sensitivity of dose-finding studies to observation errors.

    Science.gov (United States)

    Zohar, Sarah; O'Quigley, John

    2009-11-01

    The purpose of Phase I designs is to estimate the MTD (maximum tolerated dose, in practice a dose with some given acceptable rate of toxicity) while, at the same time, minimizing the number of patients treated at doses too far removed from the MTD. Our purpose here is to investigate the sensitivity of conclusions from dose-finding designs to recording or observation errors. Certain toxicities may go undetected and, conversely, certain non-toxicities may be incorrectly recorded as dose-limiting toxicities. Recording inaccuracies would be expected to have an influence on final and within trial recommendations and, in this paper, we study in greater depth this question. We focus, in particular on three designs used currently; the standard '3+3' design, the grouped up-and-down design [M. Gezmu, N. Flournoy, Group up-and-down designs for dose finding. Journal of Statistical Planning and Inference 2006; 136 (6): 1749-1764.] and the continual reassessment method (CRM, [J. O'Quigley, M. Pepe, L. Fisher, Continual reassessment method: a practical design for phase 1 clinical trials in cancer. Biometrics 1990; 46 (1): 33-48.]). A non-toxicity incorrectly recorded as a toxicity (error of first kind) has a greater influence in general than the converse (error of second kind). These results are illustrated via figures which suggest that the standard '3+3' design in particular is sensitive to errors of the second kind. Such errors can have a very important impact on drug development in that, if carried through to the Phase 2 and Phase 3 studies, we can significantly increase the probability of failure to detect efficacy as a result of having delivered an inadequate dose.

  7. Onset of efficacy and tolerability following the initiation dosing of long-acting paliperidone palmitate: post-hoc analyses of a randomized, double-blind clinical trial

    Directory of Open Access Journals (Sweden)

    Fu Dong-Jing

    2011-05-01

    Full Text Available Abstract Background Paliperidone palmitate is a long-acting injectable atypical antipsychotic for the acute and maintenance treatment of adults with schizophrenia. The recommended initiation dosing regimen is 234 mg on Day 1 and 156 mg on Day 8 via intramuscular (deltoid injection; followed by 39 to 234 mg once-monthly thereafter (deltoid or gluteal. These post-hoc analyses addressed two commonly encountered clinical issues regarding the initiation dosing: the time to onset of efficacy and the associated tolerability. Methods In a 13-week double-blind trial, 652 subjects with schizophrenia were randomized to paliperidone palmitate 39, 156, or 234 mg (corresponding to 25, 100, or 150 mg equivalents of paliperidone, respectively or placebo (NCT#00590577. Subjects randomized to paliperidone palmitate received 234 mg on Day 1, followed by their randomized fixed dose on Day 8, and monthly thereafter, with no oral antipsychotic supplementation. The onset of efficacy was defined as the first timepoint where the paliperidone palmitate group showed significant improvement in the Positive and Negative Syndrome Scale (PANSS score compared to placebo (Analysis of Covariance [ANCOVA] models and Last Observation Carried Forward [LOCF] methodology without adjusting for multiplicity using data from the Days 4, 8, 22, and 36 assessments. Adverse event (AE rates and relative risks (RR with 95% confidence intervals (CI versus placebo were determined. Results Paliperidone palmitate 234 mg on Day 1 was associated with greater improvement than placebo on Least Squares (LS mean PANSS total score at Day 8 (p = 0.037. After the Day 8 injection of 156 mg, there was continued PANSS improvement at Day 22 (p ≤ 0.007 vs. placebo and Day 36 (p Conclusions Significantly greater symptom improvement was observed by Day 8 with paliperidone palmitate (234 mg on Day 1 compared to placebo; this effect was maintained after the 156 mg Day 8 injection, with a trend towards a dose

  8. 78 FR 13257 - Pyraflufen-ethyl; Pesticide Tolerances

    Science.gov (United States)

    2013-02-27

    .... months). No dermal or systemic toxicity was seen at the limit dose (1,000 mg/kg/day). [[Page 13260... enforcement methodology (gas chromatography-mass spectrometry (GC/MS)) is available to enforce the tolerance...

  9. Hematopoietic tissue repair under chronic low daily dose irradiation

    International Nuclear Information System (INIS)

    Seed, T.M.

    1994-01-01

    The capacity of the hematopoietic system to repair constantly accruing cellular damage under chronic, low daily dose gamma irradiation is essential for the maintenance of a functional hematopoietic system, and, in turn, long term survival. In certain individuals, however, such continuous cycles of damage and repair provide an essential inductive environment for selected types of hematopathologies, e.g., myeloid leukemia (ML). We have been studying temporal and causal relationships between hematopoietic capacity, associated repair functions, and propensities for hematologic disease in canines under variable levels of chronic radiation stress (0.3-26.3 cGy d -1 ). Results indicate that the maximum exposure rate tolerated by the hematopoietic system is highly individual-specific and is based largely on the degree to which repair capacity, and, in turn, hematopoietic restoration, is augmented under chronic exposure. In low-tolerance individuals (prone to aplastic anemia, subgroup (1), the failure to augment basic m-pair functions seemingly results in a progressive accumulation of genetic and cellular damage within vital progenitorial marrow compartments particularly marked within erythroid compartments. that results in loss of reproductive capacity and ultimately in collapse of the hematopoietic system. The high-tolerance individuals (radioaccomodated and either prone- or not prone to ML, subgroup 2 ampersand 3 appear to minimize the accumulating damage effect of daily exposures by extending repair functions, which preserves reproductive integrity and fosters regenerative hematopoietic responses. As the strength of the regenerative response manifests the extent of repair augmentation, the relatively strong response of high- tolerance individuals progressing to patent ML suggests an insufficiency of repair quality rather than repair quantity

  10. Do laboratory salinity tolerances of freshwater animals correspond with their field salinity?

    Energy Technology Data Exchange (ETDEWEB)

    Kefford, Ben J.; Papas, Phil J.; Metzeling, Leon; Nugegoda, Dayanthi

    2004-06-01

    The degree to which laboratory derived measures of salinity tolerance reflect the field distributions of freshwater biota is uncertain. In this paper we compare laboratory-derived acute salinity tolerance (LC{sub 50} values) of freshwater macroinvertebrates (range 5.5-76 mS/cm) and fish (range 2.7-82 mS/cm) from southeastern Australia with the salinity from which they have been collected in the field. Only 4% of the macroinvertebrates were collected at salinity levels substantially higher than their 72-h LC{sub 50} obtained from directly transferring animals from low salinity water to the water they were tested (direct transfer LC{sub 50}). This LC{sub 50} value was correlated with the maximum salinity at which a species had been collected. For common macroinvertebrates, the maximum field salinity was approximated by the direct transfer 72-h LC{sub 50}. For adult freshwater fish, 21% of species were collected at salinities substantially greater than their acute direct transfer LC{sub 50} and there was a weak relationship between these two variables. Although there was a weak correlation between the direct transfer LC{sub 50} of early life stages of freshwater fish and the maximum field salinity, 58% of the field distribution were in higher than their LC{sub 50} values. In contrast, LC{sub 50} determined from experiments that acclimated adult fish to higher salinity (slow acclimation) provided a better indication of the field distribution: with only one fish species (7%) being in conflict with their maximum field salinity and a strong positive relationship between these variables. This study shows that laboratory measures of acute salinity tolerance can reflect the maximum salinity that macroinvertebrate and fish species inhabit and are consistent with some anecdotal observations from other studies. - Acute laboratory salinity tolerances relate to maximum salinity where organisms occur in nature.

  11. Do laboratory salinity tolerances of freshwater animals correspond with their field salinity?

    International Nuclear Information System (INIS)

    Kefford, Ben J.; Papas, Phil J.; Metzeling, Leon; Nugegoda, Dayanthi

    2004-01-01

    The degree to which laboratory derived measures of salinity tolerance reflect the field distributions of freshwater biota is uncertain. In this paper we compare laboratory-derived acute salinity tolerance (LC 50 values) of freshwater macroinvertebrates (range 5.5-76 mS/cm) and fish (range 2.7-82 mS/cm) from southeastern Australia with the salinity from which they have been collected in the field. Only 4% of the macroinvertebrates were collected at salinity levels substantially higher than their 72-h LC 50 obtained from directly transferring animals from low salinity water to the water they were tested (direct transfer LC 50 ). This LC 50 value was correlated with the maximum salinity at which a species had been collected. For common macroinvertebrates, the maximum field salinity was approximated by the direct transfer 72-h LC 50 . For adult freshwater fish, 21% of species were collected at salinities substantially greater than their acute direct transfer LC 50 and there was a weak relationship between these two variables. Although there was a weak correlation between the direct transfer LC 50 of early life stages of freshwater fish and the maximum field salinity, 58% of the field distribution were in higher than their LC 50 values. In contrast, LC 50 determined from experiments that acclimated adult fish to higher salinity (slow acclimation) provided a better indication of the field distribution: with only one fish species (7%) being in conflict with their maximum field salinity and a strong positive relationship between these variables. This study shows that laboratory measures of acute salinity tolerance can reflect the maximum salinity that macroinvertebrate and fish species inhabit and are consistent with some anecdotal observations from other studies. - Acute laboratory salinity tolerances relate to maximum salinity where organisms occur in nature

  12. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  13. Dose optimization in simulated permanent interstitial implant of prostate brachytherapy

    International Nuclear Information System (INIS)

    Faria, Fernando Pereira de

    2006-01-01

    Any treatment of cancer that uses some modality of radiotherapy is planned before being executed. In general the goal in radiotherapy is to irradiate the target to be treated minimizing the incidence of radiation in healthy surrounding tissues. The planning differ among themselves according to the modality of radiotherapy, the type of cancer and where it is located. This work approaches the problem of dose optimization for the planning of prostate cancer treatment through the modality of low dose-rate brachytherapy with Iodine 125 or Palladium 103 seeds. An algorithm for dose calculation and optimization was constructed to find the seeds configuration that better fits the relevant clinical criteria such as as the tolerated dose by the urethra and rectum and the desired dose for prostate. The algorithm automatically finds this configuration from the prostate geometry established in two or three dimensions by using images of ultrasound, magnetic resonance or tomography and from the establishment of minimum restrictions to the positions of the seeds in the prostate and needles in a template. Six patterns of seeds distribution based on clinical criteria were suggested and tested in this work. Each one of these patterns generated a space of possible seeds configurations for the prostate tested by the dose calculation and optimization algorithm. The configurations that satisfied the clinical criteria were submitted to a test according to an optimization function suggested in this work. The configuration that produced maximum value for this function was considered the optimized one. (author)

  14. Is the dose distribution distorted in IMRT and RapidArc treatment when patient plans are swapped across beam‐matched machines?

    Science.gov (United States)

    Radha, Chandrasekaran Anu; Subramani, Vendhan; Gunasekaran, Madhan Kumar

    2016-01-01

    The purpose of this study is to evaluate the degree of dose distribution distortion in advanced treatments like IMRT and RapidArc when patient plans are swapped across dosimetrically equivalent so‐called “beam‐matched” machines. For this purpose the entire work is divided into two stages. At forefront stage all basic beam properties of 6 MV X‐rays like PDD, profiles, output factors, TPR20/10 and MLC transmission of two beam‐matched machines — Varian Clinac iX and Varian 600 C/D Unique — are compared and evaluated for differences. At second stage 40 IMRT and RapidArc patient plans from the pool of head and neck (H&N) and pelvis sites are selected for the study. The plans are swapped across the machines for dose recalculation and the DVHs of target and critical organs are evaluated for dose differences. Following this, the accuracy of the beam‐matching at the TPS level for treatments like IMRT and RapidArc are compared. On PDD, profile (central 80%) and output factor comparison between the two machines, a maximum percentage disagreement value of −2.39%,−2.0% and −2.78%, respectively, has been observed. The maximum dose difference observed at volumes in IMRT and RapidArc treatments for H&N dose prescription of 69.3 Gy/33 fractions is 0.88 Gy and 0.82 Gy, respectively. Similarly, for pelvis, with a dose prescription of 50 Gy/25 fractions, a maximum dose difference of 0.55 Gy and 0.53 Gy is observed at volumes in IMRT and RapidArc treatments, respectively. Overall results of the swapped plans between two machines' 6 MV X‐rays are well within the limits of accepted clinical tolerance. PACS number(s): 87.56.bd PMID:27685106

  15. Tolerance and immunity in mice infected with herpes simplex virus: studies on the mechanism of tolerance to delayed-type hypersensitivity.

    Science.gov (United States)

    Nash, A A; Phelan, J; Gell, P G; Wildy, P

    1981-06-01

    Tolerance to delayed-type hypersensitivity is produced in mice following an intravenous injection of herpes simplex virus. This form of tolerance is produced early on, following simultaneous injections of virus subcutaneously and intravenously, and is long lasting (greater than 100 days). The early tolerance mechanism is resistant to high doses of cyclophosphamide and is not transferable by serum or spleen cells taken after 7 days. However, spleen cells taken at 14 days onwards inhibit the induction of delayed hypersensitivity when transferred to normal syngeneic recipients. These cells are T lymphocytes and are specific for the herpes type used in the induction.

  16. An FMEA evaluation of intensity modulated radiation therapy dose delivery failures at tolerance criteria levels.

    Science.gov (United States)

    Faught, Jacqueline Tonigan; Balter, Peter A; Johnson, Jennifer L; Kry, Stephen F; Court, Laurence E; Stingo, Francesco C; Followill, David S

    2017-11-01

    The objective of this work was to assess both the perception of failure modes in Intensity Modulated Radiation Therapy (IMRT) when the linac is operated at the edge of tolerances given in AAPM TG-40 (Kutcher et al.) and TG-142 (Klein et al.) as well as the application of FMEA to this specific section of the IMRT process. An online survey was distributed to approximately 2000 physicists worldwide that participate in quality services provided by the Imaging and Radiation Oncology Core - Houston (IROC-H). The survey briefly described eleven different failure modes covered by basic quality assurance in step-and-shoot IMRT at or near TG-40 (Kutcher et al.) and TG-142 (Klein et al.) tolerance criteria levels. Respondents were asked to estimate the worst case scenario percent dose error that could be caused by each of these failure modes in a head and neck patient as well as the FMEA scores: Occurrence, Detectability, and Severity. Risk probability number (RPN) scores were calculated as the product of these scores. Demographic data were also collected. A total of 181 individual and three group responses were submitted. 84% were from North America. Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5 to 45 yr (average 18 yr). A total of 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems, and linear accelerator manufacturers were represented. All failure modes received widely varying scores ranging from 1 to 10 for occurrence, at least 1-9 for detectability, and at least 1-7 for severity. Ranking failure modes by RPN scores also resulted in large variability, with each failure mode being ranked both most risky (1st) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity

  17. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  18. Preclinical investigation of tolerance and antitumour activity of new fluorodeoxyglucose-coupled chlorambucil alkylating agents.

    Science.gov (United States)

    Miot-Noirault, Elisabeth; Reux, Bastien; Debiton, Eric; Madelmont, Jean-Claude; Chezal, Jean-Michel; Coudert, Pascal; Weber, Valérie

    2011-06-01

    Our strategy is to increase drug accumulation in target tumour cells using specific "vectors" tailored to neoplastic tissue characteristics, which ideally are not found in healthy tissues. The aim of this work was to use 2-fluoro-2-deoxyglucose (FDG) as a drug carrier, in view of its well-known accumulation by most primary and disseminated human tumours. We had previously selected two FDG-cytotoxic conjugates of chlorambucil (CLB), i.e. compounds 21a and 40a, on the basis of their in vitro profiles. Here we investigated the antitumour profile and tolerance of these compounds in vitro and in vivo in two murine cell lines of solid tumours. In vitro, we found that micromolar concentrations of compounds 21a and 40a inhibited proliferation of B16F0 and CT-26 cell lines. Interestingly, compounds 21a and 40a were found to act at different levels in the cell cycle: S and subG1 accumulation for 21a and G2 accumulation for 40a. In vivo, a single-dose-finding study to select the Maximum Tolerated Dose (MTD) by the intraperitoneal route (IP) showed that the two peracetylated glucoconjugates of CLB were less toxic than CLB itself. When given to tumour-bearing mice (melanoma and colon carcinoma models), according to a "q4d × 3" schedule (i.e., three doses at 4-day intervals) both compounds demonstrated a promising antitumour activity, with Log Cell Kill (LCK) values higher than 1.3 in both B16F0 and CT-26 models. Hence compounds 21a and 40a are good candidates for further works to develop new highly active antineoplastic compounds.

  19. Attenuation of a radiation-induced conditioned taste aversion after the development of ethanol tolerance

    International Nuclear Information System (INIS)

    Hunt, W.A.; Rabin, B.M.

    1988-01-01

    An attempt to reduce a radiation-induced conditioned taste aversion (CTA) was undertaken by rendering animals tolerant to ethanol. Ethanol tolerance, developed over 5 days, was sufficient to block a radiation-induced taste aversion, as well as an ethanol-induced CTA. Several intermittent doses of ethanol, which did not induce tolerance but removed the novelty of the conditioning stimulus, blocked an ethanol-induced CTA but not the radiation-induced CTA. A CTA induced by doses of radiation up to 500 rads was attenuated. These data suggest that radioprotection developing in association with ethanol tolerance is a result of a physiological response to the chronic presence of ethanol not to the ethanol itself

  20. A phase I/II trial of intensity modulated radiation (IMRT) dose escalation with concurrent fixed-dose rate gemcitabine (FDR-G) in patients with unresectable pancreatic cancer.

    Science.gov (United States)

    Ben-Josef, Edgar; Schipper, Mathew; Francis, Isaac R; Hadley, Scott; Ten-Haken, Randall; Lawrence, Theodore; Normolle, Daniel; Simeone, Diane M; Sonnenday, Christopher; Abrams, Ross; Leslie, William; Khan, Gazala; Zalupski, Mark M

    2012-12-01

    Local failure in unresectable pancreatic cancer may contribute to death. We hypothesized that intensification of local therapy would improve local control and survival. The objectives were to determine the maximum tolerated radiation dose delivered by intensity modulated radiation with fixed-dose rate gemcitabine (FDR-G), freedom from local progression (FFLP), and overall survival (OS). Eligibility included pathologic confirmation of adenocarcinoma, radiographically unresectable, performance status of 0-2, absolute neutrophil count of ≥ 1,500/mm(3), platelets ≥ 100,000/mm(3), creatinine CRM (Time-to-Event Continual Reassessment Method) with the target dose-limiting toxicity (DLT) rate set to 0.25. Fifty patients were accrued. DLTs were observed in 11 patients: G3/4 anorexia, nausea, vomiting, and/or dehydration (7); duodenal bleed (3); duodenal perforation (1). The recommended dose is 55 Gy, producing a probability of DLT of 0.24. The 2-year FFLP is 59% (95% confidence interval [CI]: 32-79). Median and 2-year overall survival are 14.8 months (95% CI: 12.6-22.2) and 30% (95% CI 17-45). Twelve patients underwent resection (10 R0, 2 R1) and survived a median of 32 months. High-dose radiation therapy with concurrent FDR-G can be delivered safely. The encouraging efficacy data suggest that outcome may be improved in unresectable patients through intensification of local therapy. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Results of a Phase I trial of concurrent chemotherapy and escalating doses of radiation for unresectable non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Schild, Steven E.; McGinnis, William L.; Graham, David; Hillman, Shauna; Fitch, Tom R.; Northfelt, Donald; Garces, Yolanda I.; Shahidi, Homayoon; Tschetter, Loren K.; Schaefer, Paul L.; Adjei, Alex; Jett, James

    2006-01-01

    Purpose: This trial was performed to determine the maximum tolerated dose (MTD) of radiation that can be administered with carboplatin and paclitaxel. Methods and Materials: This trial included 15 patients with unresectable non-small-cell lung cancer. Paclitaxel (50 mg/m 2 ) and carboplatin (area under the curve = 2) were given weekly during radiation therapy (RT). The RT included 2 Gy daily to an initial dose of 70 Gy, and the dose was increased in 4 Gy increments until determining the MTD. The MTD was defined as the highest safely tolerated dose where at most 1 patient of 6 experienced dose-limiting toxicity (DLT) with the next higher dose having at least 2 of 6 patients experiencing DLT. Three-dimensional treatment planning techniques were used without prophylactic nodal RT. Results: Two patients were not evaluable because they did not receive therapy according to the protocol. No DLTs occurred in the 3 patients who received 70 Gy, 1 DLT occurred in the 6 patients who received 74 Gy, and 2 DLTs occurred in the 4 patients who received 78 Gy. The DLTs included Grade 3 pneumonitis (n = 2) and Grade 4 pneumonitis (n = 1). There have been 3 deaths during follow-up ranging from 14 to 38 months (median, 28 months). Conclusions: The MTD of the RT was 74 Gy with weekly carboplatin and paclitaxel. The Phase II portion of this trial is currently under way. The goal is to improve local control and survival with higher doses of RT delivered with this combined modality approach

  2. A Comparison of Four Indices for Combining Distance and Dose Differences

    International Nuclear Information System (INIS)

    Thomas, Simon J.; Cowley, Ian R.

    2012-01-01

    Purpose: When one is comparing two dose distributions, a number of methods have been published to combine dose difference and distance to agreement into a single measure. Some have been defined as pass/fail indices and some as numeric indices. We show that the pass/fail indices can all be used to derive numeric indices, and we compare the results of using these indices to evaluate one-dimensional (1D) and three-dimensional (3D) dose distributions, with the aim of selecting the most appropriate index for use in different circumstances. Methods and Materials: The indices compared are the gamma index, the kappa index, the index in International Commission on Radiation Units and Measurements Report 83, and a box index. Comparisons are made for 1D and 3D distributions. The 1D distribution is chosen to have a variety of dose gradients. The 3D distribution is taken from a clinical treatment plan. The effect of offsetting distributions by known distances and doses is studied. Results: The International Commission on Radiation Units and Measurements Report 83 index causes large discontinuities unless the dose gradient cutoff is set to equal the ratio of the dose tolerance to the distance tolerance. If it is so set, it returns identical results to the kappa index. Where the gradient is very high or very low, all the indices studied in this article give similar results for the same tolerance values. For moderate gradients, they differ, with the box index being the least strict, followed by the gamma index, and with the kappa index being the most strict. Conclusions: If the clinical tolerances are much greater than the uncertainties of the measuring system, the kappa index should be used, with tolerance values determined by the clinical tolerances. In cases where the uncertainties of the measuring system dominate, the box index will be best able to determine errors in the delivery system.

  3. Pharmacology of ayahuasca administered in two repeated doses.

    Science.gov (United States)

    Dos Santos, Rafael G; Grasa, Eva; Valle, Marta; Ballester, Maria Rosa; Bouso, José Carlos; Nomdedéu, Josep F; Homs, Rosa; Barbanoj, Manel J; Riba, Jordi

    2012-02-01

    Ayahuasca is an Amazonian tea containing the natural psychedelic 5-HT(2A/2C/1A) agonist N,N-dimethyltryptamine (DMT). It is used in ceremonial contexts for its visionary properties. The human pharmacology of ayahuasca has been well characterized following its administration in single doses. To evaluate the human pharmacology of ayahuasca in repeated doses and assess the potential occurrence of acute tolerance or sensitization. In a double-blind, crossover, placebo-controlled clinical trial, nine experienced psychedelic drug users received PO the two following treatment combinations at least 1 week apart: (a) a lactose placebo and then, 4 h later, an ayahuasca dose; and (b) two ayahuasca doses 4 h apart. All ayahuasca doses were freeze-dried Amazonian-sourced tea encapsulated to a standardized 0.75 mg DMT/kg bodyweight. Subjective, neurophysiological, cardiovascular, autonomic, neuroendocrine, and cell immunity measures were obtained before and at regular time intervals until 12 h after first dose administration. DMT plasma concentrations, scores in subjective and neurophysiological variables, and serum prolactin and cortisol were significantly higher after two consecutive doses. When effects were standardized by plasma DMT concentrations, no differences were observed for subjective, neurophysiological, autonomic, or immunological effects. However, we observed a trend to reduced systolic blood pressure and heart rate, and a significant decrease for growth hormone (GH) after the second ayahuasca dose. Whereas there was no clear-cut tolerance or sensitization in the psychological sphere or most physiological variables, a trend to lower cardiovascular activation was observed, together with significant tolerance to GH secretion.

  4. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  5. Is the maximum permissible radiation burden for the population indeed permissible

    International Nuclear Information System (INIS)

    Renesse, R.L. van.

    1975-01-01

    It is argued that legislation based on the ICRP doses will, under economical influences, lead to a situation where the population is exposed to radiation doses near the maximum permissible dose. Due to cumulative radiation effects, this will introduce unacceptable health risks. Therefore, it will be necessary to lower the legal dose limit of 170 millrem per year per person by a factor 10 to 20

  6. Influence of irradiation upon neonative tolerance state induced in rabbit

    International Nuclear Information System (INIS)

    Servant, P.; Marquer, C.

    An attempt was made to determine the effect of whole-body irradiation on the establishment of a state of tolerance in new-born rabbits by the intraperitoneal injection of 1mg of human serum albumin. Simultaneous irradiation (doses of 200, 150, 100 rads) and antigen injections inhibited the establishment of this tolerance [fr

  7. A Phase I Dose-Escalation Study (ISIDE-BT-1) of Accelerated IMRT With Temozolomide in Patients With Glioblastoma

    International Nuclear Information System (INIS)

    Morganti, Alessio G.; Balducci, Mario; Salvati, Maurizio; Esposito, Vincenzo; Romanelli, Pantaleo; Ferro, Marica; Calista, Franco; Digesu, Cinzia; Macchia, Gabriella; Ianiri, Massimo; Deodato, Francesco; Cilla, Savino; Piermattei, Angelo M.P.; Valentini, Vincenzo; Cellini, Numa; Cantore, Gian Paolo

    2010-01-01

    Purpose: To determine the maximum tolerated dose (MTD) of fractionated intensity-modulated radiotherapy (IMRT) with temozolomide (TMZ) in patients with glioblastoma. Methods and Materials: A Phase I clinical trial was performed. Eligible patients had surgically resected or biopsy-proven glioblastoma. Patients started TMZ (75 mg/day) during IMRT and continued for 1 year (150-200 mg/day, Days 1-5 every 28 days) or until disease progression. Clinical target volume 1 (CTV1) was the tumor bed ± enhancing lesion with a 10-mm margin; CTV2 was the area of perifocal edema with a 20-mm margin. Planning target volume 1 (PTV1) and PTV2 were defined as the corresponding CTV plus a 5-mm margin. IMRT was delivered in 25 fractions over 5 weeks. Only the dose for PTV1 was escalated (planned dose escalation: 60 Gy, 62.5 Gy, 65 Gy) while maintaining the dose for PTV2 (45 Gy, 1.8 Gy/fraction). Dose limiting toxicities (DLT) were defined as any treatment-related nonhematological adverse effects rated as Grade ≥3 or any hematological toxicity rated as ≥4 by Radiation Therapy Oncology Group (RTOG) criteria. Results: Nineteen consecutive glioblastoma were treated with step-and-shoot IMRT, planned with the inverse approach (dose to the PTV1: 7 patients, 60 Gy; 6 patients, 62.5 Gy; 6 patients, 65 Gy). Five coplanar beams were used to cover at least 95% of the target volume with the 95% isodose line. Median follow-up time was 23 months (range, 8-40 months). No patient experienced DLT. Grade 1-2 treatment-related neurologic and skin toxicity were common (11 and 19 patients, respectively). No Grade >2 late neurologic toxicities were noted. Conclusion: Accelerated IMRT to a dose of 65 Gy in 25 fractions is well tolerated with TMZ at a daily dose of 75 mg.

  8. A new reversible and potent P2Y12 receptor antagonist (ACT-246475): tolerability, pharmacokinetics, and pharmacodynamics in a first-in-man trial.

    Science.gov (United States)

    Baldoni, Daniela; Bruderer, Shirin; Krause, Andreas; Gutierrez, Marcello; Gueret, Pierre; Astruc, Béatrice; Dingemanse, Jasper

    2014-11-01

    ACT-246475 is a new reversible, selective, and potent antagonist of the platelet P2Y12 receptor. This study was a first-in-man trial investigating the tolerability, pharmacokinetics, and pharmacodynamics of single oral doses of ACT-246475 and its di-ester prodrug (ACT-281959) in healthy males. The study had a double-blind, randomized, ascending single-dose design with an oral formulation F1 (i.e., ACT-281959 or placebo) (Part I) and an open-label, randomized, 3-period, crossover design comparing exploratory formulations of ACT-281959 (F2) 70 mg and ACT-246475 (dF) 50 mg to F1 70 mg (Part II). In Part I, doses up to 1,000 mg were tested in 40 healthy subjects. Nine healthy subjects were enrolled in Part II. Standard safety parameters, inhibition of platelet aggregation, and ACT-246475 plasma concentrations were measured. Non-compartmental pharmacokinetic analysis was performed. All doses and formulations were well tolerated. The most frequent adverse event was headache, whereas no events of bleeding or dyspnea were reported. In Part I, ACT-246475 area under the plasma concentration-time curve (AUC) increased dose-proportionally whereas maximum plasma concentration (C max) was less than dose-proportional. The highest C max [geometric mean (95 % CI)] at 1,000 mg was 13.8 (9.7, 19.5) pmol/mL at 4.5 h post-dose, terminal half-life (t ½) was ~10 h. ACT-246475 C max and AUC0-∞ ratios of geometric means (90 % CI) using F1 as reference, for F2 were 8.5 (5.42, 13.35) and 3.4 (2.40, 4.82), respectively, and for dF 2.2 (1.42, 3.49) and 1.5 (1.07, 2.16), respectively. Mean peak platelet inhibition was 31.0 % after F1 (1,000 mg) and 47.8 % after F2. Oral doses of ACT-281959 and ACT-246475 were well tolerated. Platelet inhibition correlated with ACT-246475 exposure. Exploratory formulations enhanced the bioavailability and antiplatelet effect of ACT-246475.

  9. The influence of dose fractionation and dose rate on normal tissue responses

    International Nuclear Information System (INIS)

    Barendsen, G.W.

    1982-01-01

    An analysis of responses of a variety of normal tissues in animals to fractionated irradiations has been made with the aim of developing a formalism for the prediction of tolerance doses as a function of the dose per fraction and the overall treatment time. An important feature of the formalism is that it is directly based on radiological insights and therefore provides a logical concept to account for the diversity of tissue responses. (Auth.)

  10. Estimating winter survival of winter wheat by simulations of plant frost tolerance

    NARCIS (Netherlands)

    Bergjord Olsen, A.K.; Persson, T.; Wit, de A.; Nkurunziza, L.; Sindhøj, E.; Eckersten, H.

    2018-01-01

    Based on soil temperature, snow depth and the grown cultivar's maximum attainable level of frost tolerance (LT50c), the FROSTOL model simulates development of frost tolerance (LT50) and winter damage, thereby enabling risk calculations for winter wheat survival. To explore the accuracy of this

  11. Tissue tolerance under the combination treatment of maxillary cancer

    Energy Technology Data Exchange (ETDEWEB)

    Egawa, J [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Ono, I; Suzuki, K; Takeda, C; Ebihara, S

    1977-06-01

    The tissue tolerance doses of the maxillary sinus structures were estimated when they were subjected to treatment for maxillary cancer by the usual combination of surgery, radiotherapy, and regional arterial infusion of 5-fluorouracil. Equivalent single dose calculation was applied with irreversible tissue damage as an indicator. The retardation of epithelialization of the maxillary sinus operated upon appeared to be correlated with the dose delivered. The study indicated that 2,200 rad expressed by equivalent single dose is a safe dose level for sufficient epithelialization. The safety dose level for the bony structure, exposed by surgery, seemed to be at 1,800 rad.

  12. 76 FR 18899 - Indaziflam; Pesticide Tolerances

    Science.gov (United States)

    2011-04-06

    ... were generally observed in the available subchronic and chronic studies. No systemic toxicity was... limited to doses that also caused systemic toxicity in the adult. In the rat developmental toxicity study... to enforce the tolerance expression. The method is able to determine, separately, residues of...

  13. Phase I dose escalation clinical trial of phenylbutyrate sodium administered twice daily to patients with advanced solid tumors.

    Science.gov (United States)

    Camacho, Luis H; Olson, Jon; Tong, William P; Young, Charles W; Spriggs, David R; Malkin, Mark G

    2007-04-01

    Phenylbutyrate (PBA), and its metabolite phenylacetate (PAA), induce growth inhibition and cellular differentiation in multiple tumor models. However, despite their potential anti-cancer properties, several pharmacodynamic aspects remain unknown. We conducted a dose escalating trial to evaluate twice-daily intravenous PBA infusions for two consecutive weeks (Monday through Friday) every month at five dose levels (60-360 mg/kg/day). Twenty-one patients with the following malignancies were treated: colon carcinoma 4, non-small cell lung carcinoma 4; anaplastic astrocytoma 3, glioblastoma multiforme 3, bladder carcinoma 2, sarcoma 2, and ovarian carcinoma, rectal hemangiopericytoma, and pancreatic carcinoma 1 each. Conversion of PBA to PAA and phenylacetylglutamine (PAG) was documented without catabolic saturation. Plasma content of PBA > or =1 mM was documented for only 3 h following each dose at the top two dosages. The therapy was well tolerated overall. Common adverse effects included grade 1 nausea/vomiting, fatigue, and lightheadedness. Dose limiting toxicities were short-term memory loss, sedation, confusion, nausea, and vomiting. Two patients with anaplastic astrocytoma and a patient with glioblastoma remained stable without tumor progression for 5, 7, and 4 months respectively. Administration of PBA in a twice-daily infusion schedule is safe. The maximum tolerated dose is 300 mg/kg/day. Study designs with more convenient treatment schedules and specific molecular correlates may help to further delineate the mechanism of action of this compound. Future studies evaluating PBA's ability to induce histone acetylation and cell differentiation alone or in combination with other anti-neoplastics are recommended.

  14. An analysis of tolerance levels in IMRT quality assurance procedures

    International Nuclear Information System (INIS)

    Basran, Parminder S.; Woo, Milton K.

    2008-01-01

    Increased use of intensity modulated radiation therapy (IMRT) has resulted in increased efforts in patient quality assurance (QA). Software and detector systems intended to streamline the IMRT quality assurance process often report metrics, such as percent discrepancies between measured and computed doses, which can be compared to benchmark or threshold values. The purpose of this work is to examine the relationships between two different types of IMRT QA processes in order to define, or refine, appropriate tolerances values. For 115 IMRT plans delivered in a 3 month period, we examine the discrepancies between (a) the treatment planning system (TPS) and results from a commercial independent monitor unit (MU) calculation program; (b) TPS and results from a commercial diode-array measurement system; and (c) the independent MU calculation and the diode-array measurements. Statistical tests were performed to assess significance in the IMRT QA results for different disease site and machine models. There is no evidence that the average total dose discrepancy in the monitor unit calculation depends on the disease site. Second, the discrepancies in the two IMRT QA methods are independent: there is no evidence that a better --or worse--monitor unit validation result is related to a better--or worse--diode-array measurement result. Third, there is marginal benefit in repeating the independent MU calculation with a more suitable dose point, if the initial IMRT QA failed a certain tolerance. Based on these findings, the authors conclude at some acceptable tolerances based on disease site and IMRT QA method. Specifically, monitor unit validations are expected to have a total dose discrepancy of 3% overall, and 5% per beam, independent of disease site. Diode array measurements are expected to have a total absolute dose discrepancy of 3% overall, and 3% per beam, independent of disease site. The percent of pixels exceeding a 3% and 3 mm threshold in a gamma analysis should be

  15. Re-irradiation tolerance in the rat spinal cord

    International Nuclear Information System (INIS)

    Shun Wong, C.; Poon, J.K.; Hill, R.P.

    1993-01-01

    The influence of the level of initial radiation damage on the long term recovery and re-irradiation tolerance in the rat spinal cord was investigated. Rats were irradiated with 0, 10, 20, 30 and 36 daily fractions of 2.15 Gy initially representing 0, 25, 50, 75 and 90% of cord tolerance. After an interval of 20 weeks, retreatments were given using graded single doses of X-ray. The end-point was paralysis of the forelimbs due to white matter necrosis. Latent times to paralysis were inversely proportional to the level of initial injury and retreatment doses. The retreatment ED 50 s were 19.0, 17.0, 15.7, 14.0 and 11.8 Gy for the control animals and animals irradiated initially with 10. 20, 30 and 36 fractions of 2.15 Gy respectively. Using the extrapolated response dose (ERD) concept, α/β of 3.0 Gy, the retreatment of ED 50 s in % ERD were 81, 70, 58 and 42% after initial doses of 25, 50, 75 and 90% ERD respectively. The level of initial injury appeared to influence the proportion of residual injury. For an initial injury of 25 and 90% of ERD, the respective residual injury was 74 and 65% of the initial damage; for an initial injury of 50 and 75% ERD, the residual injury decreased to 59 and 57% respectively. It is concluded that there was significant long-term recovery in the rat spinal cord, and that the level of initial radiation damage influenced both the treatment tolerance and the time expression of injury. (author). tabs

  16. Influence of salicylic acid pre-treatment on cadmium tolerance and ...

    African Journals Online (AJOL)

    Dose-dependent changes in cadmium (Cd) tolerance, non-protein thiol (NP-SH) production and their relationship were investigated in sixteen-day-old flax (Linum usitatissimum L.) seedlings derived from seeds pre-soaked with various salicylic acid (SA) doses and grown hydroponically under increased Cd concentrations ...

  17. Patient doses in digital cardiac imaging

    International Nuclear Information System (INIS)

    Huda, W.; Ogden, K.M.; Roskopf, M.L.; Phadke, K.

    2001-01-01

    In this pilot study, we obtained estimates of entrance skin doses and the corresponding effective doses to patients undergoing digital cardiac imaging procedures on a GE Advantx LC/LP Plus system. Data were obtained for six patients undergoing diagnostic examinations and six patients who had interventional procedures. For each patient examination, radiographic techniques for fluoroscopic and digital cine imaging were recorded, together with the irradiation geometry. The projection with the highest exposure resulted in an average skin dose of 0.64 ± 0.41 Gy (maximum of 1.6 Gy). The average patient skin doses taking into account overlapping projections was 1.1 ± 0.8 Gy (maximum of 3.0 Gy). The exposure area product (EAP) incident on the patient was converted into the energy imparted to the patient and the corresponding effective dose. The average patient effective dose was 28 ± 14 mSv (maximum 62 mSv), with the resultant average fatal cancer risk estimated to be of the order of 8x10 -3 . Average doses for interventional procedures in cardiac imaging are higher than those associated with diagnostic examinations by approximately 50%. (author)

  18. Spinal Cord Tolerance in the Age of Spinal Radiosurgery: Lessons From Preclinical Studies

    International Nuclear Information System (INIS)

    Medin, Paul M.; Boike, Thomas P.

    2011-01-01

    Clinical implementation of spinal radiosurgery has increased rapidly in recent years, but little is known regarding human spinal cord tolerance to single-fraction irradiation. In contrast, preclinical studies in single-fraction spinal cord tolerance have been ongoing since the 1970s. The influences of field length, dose rate, inhomogeneous dose distributions, and reirradiation have all been investigated. This review summarizes literature regarding single-fraction spinal cord tolerance in preclinical models with an emphasis on practical clinical significance. The outcomes of studies that incorporate uniform irradiation are surprisingly consistent among multiple small- and large-animal models. Extensive investigation of inhomogeneous dose distributions in the rat has demonstrated a significant dose-volume effect while preliminary results from one pig study are contradictory. Preclinical spinal cord dose-volume studies indicate that dose distribution is more critical than the volume irradiated suggesting that neither dose-volume histogram analysis nor absolute volume constraints are effective in predicting complications. Reirradiation data are sparse, but results from guinea pig, rat, and pig studies are consistent with the hypothesis that the spinal cord possesses a large capacity for repair. The mechanisms behind the phenomena observed in spinal cord studies are not readily explained and the ability of dose response models to predict outcomes is variable underscoring the need for further investigation. Animal studies provide insight into the phenomena and mechanisms of radiosensitivity but the true significance of animal studies can only be discovered through clinical trials.

  19. 78 FR 20461 - Flumioxazin; Pesticide Tolerances

    Science.gov (United States)

    2013-04-05

    ... offspring were observed at doses lower than those that caused parental/systemic toxicity, and because the reproductive effects in offspring were considered to be more severe than the parental/systemic effects. 3... available to enforce the tolerance expression. The method may be requested from: Chief, Analytical Chemistry...

  20. Application of ICRP recommendations relevant to internal dose

    International Nuclear Information System (INIS)

    Cowser, K.E.; Snyder, W.S.; Struxness, E.G.

    1969-01-01

    The intent of this paper is to review several of the basic concepts of radiation protection (with emphasis on internal dose) currently recommended by the International Commission on radiological Protection (ICRP), to summarize the assumptions and methods used in the calculation of internal dose, and to illustrate by example the practical application of the pertinent guidelines. Two broad subject areas are considered: (1) standards of radiation protection and (2) bases of internal dose estimation. Topics discussed within the framework of radiation protection standards include maximum permissible dose, categories of radiation exposure, maximum permissible dose commitment, simultaneous internal and external exposure, multiple organ exposure, and size of the exposed group. Discussion of internal dose estimation is limited to selected items that include the body burden of radionuclides and the calculation of absorbed dose, the dose equivalent, the derivation of maximum permissible concentration (MPC), the relationship of stable element intake to the MPC, and short term and chronic exposure situations. (author)

  1. Application of ICRP recommendations relevant to internal dose

    Energy Technology Data Exchange (ETDEWEB)

    Cowser, K E; Snyder, W S; Struxness, E G [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1969-07-01

    The intent of this paper is to review several of the basic concepts of radiation protection (with emphasis on internal dose) currently recommended by the International Commission on radiological Protection (ICRP), to summarize the assumptions and methods used in the calculation of internal dose, and to illustrate by example the practical application of the pertinent guidelines. Two broad subject areas are considered: (1) standards of radiation protection and (2) bases of internal dose estimation. Topics discussed within the framework of radiation protection standards include maximum permissible dose, categories of radiation exposure, maximum permissible dose commitment, simultaneous internal and external exposure, multiple organ exposure, and size of the exposed group. Discussion of internal dose estimation is limited to selected items that include the body burden of radionuclides and the calculation of absorbed dose, the dose equivalent, the derivation of maximum permissible concentration (MPC), the relationship of stable element intake to the MPC, and short term and chronic exposure situations. (author)

  2. A reversible albumin-binding growth hormone derivative is well tolerated and possesses a potential once-weekly treatment profile.

    Science.gov (United States)

    Rasmussen, Michael Højby; Olsen, Minna W Brændholt; Alifrangis, Lene; Klim, Søren; Suntum, Mette

    2014-10-01

    Human growth hormone (hGH) replacement therapy currently requires daily sc injections for years/lifetime, which may be both inconvenient and distressing for patients. NNC0195-0092 is a novel hGH derivative intended for once-weekly treatment of GH deficiency. A noncovalent albumin binding moiety is attached to the hGH backbone. Clearance is reduced as a consequence of a reversible binding to circulating serum albumin, which prolongs the pharmacodynamic (PD) effect. To evaluate safety, local tolerability, pharmacokinetics (PK), and pharmacodynamics (PD) of a single dose (SD) and multiple doses (MD) of NNC0195-0092. Randomized, single-center, placebo-controlled, double-blind, SD/MD, dose-escalation trial of 105 healthy male subjects. NNC0195-0092 sc administration: Five cohorts of eight subjects received one dose of NNC0195-0092 (0.01-0.32 mg/kg) (n = 6) or placebo (n = 2). Sixteen subjects (equal numbers of Japanese and non-Asian) received once-weekly doses of NNC0195-0092 (0.02-0.24 mg/kg; n=12) or placebo (n=4) for 4 weeks. Blood samples were drawn for assessment of safety, PK, IGF-1, and IGF binding protein 3 profiles and anti-drug antibodies. SD and MD of NNC0195-0092 were well tolerated at all dose levels. No safety concerns or local tolerability issues were identified. A dose-dependent IGF-1 response was observed. IGF-1 profiles suggest that NNC0195-0092 may be suitable for once-weekly dosing, with a clinically relevant dose ≤0.08 mg/kg/week. No differences in PK and PD were observed between Japanese and non-Asian subjects. SD and MD of NNC0195-0092 administered to healthy Japanese and non-Asian male subjects were well tolerated at all doses. The present trial suggests that NNC0195-0092 has the potential for an efficacious, well-tolerated, once-weekly GH treatment.

  3. Tolerance of snakes to hypergravity

    Science.gov (United States)

    Lillywhite, H. B.; Ballard, R. E.; Hargens, A. R.

    1996-01-01

    Sensitivity of carotid blood flow to increased gravitational force acting in the head-to-tail direction(+Gz) was studied in diverse species of snakes hypothesized to show adaptive variation of response. Tolerance to increased gravity was measured red as the maximum graded acceleration force at which carotid blood flow ceased and was shown to vary according to gravitational adaptation of species defined by their ecology and behavior. Multiple regression analysis showed that gravitational habitat, but not body length, had a significant effect on Gz tolerance. At the extremes, carotid blood flow decreased in response to increasing G force and approached zero near +1 Gz in aquatic and ground-dwelling species, whereas in climbing species carotid flow was maintained at forces in excess of +2 Gz. Tolerant (arboreal) species were able to withstand hypergravic forces of +2 to +3 Gz for periods up to 1 h without cessation of carotid blood flow or loss of body movement and tongue flicking. Data suggest that the relatively tight skin characteristic of tolerant species provides a natural antigravity suit and is of prime importance in counteracting Gz stress on blood circulation.

  4. A fixed-dose approach to conducting emamectin benzoate tolerance assessments on field-collected sea lice, Lepeophtheirus salmonis.

    Science.gov (United States)

    Whyte, S K; Westcott, J D; Elmoslemany, A; Hammell, K L; Revie, C W

    2013-03-01

    In New Brunswick, Canada, the sea louse, Lepeophtheirus salmonis, poses an on-going management challenge to the health and productivity of commercially cultured Atlantic salmon, Salmo salar. While the in-feed medication, emamectin benzoate (SLICE® ; Merck), has been highly effective for many years, evidence of increased tolerance has been observed in the field since late 2008. Although bioassays on motile stages are a common tool to monitor sea lice sensitivity to emamectin benzoate in field-collected sea lice, they require the collection of large numbers of sea lice due to inherent natural variability in the gender and stage response to chemotherapeutants. In addition, sensitive instruments such as EC(50) analysis may be unnecessarily complex to characterize susceptibility subsequent to a significant observed decline in efficacy. This study proposes an adaptation of the traditional, dose-response format bioassay to a fixed-dose method. Analysis of 657 bioassays on preadult and adult stages of sea lice over the period 2008-2011 indicated a population of sea lice in New Brunswick with varying degrees of susceptibility to emamectin benzoate. A seasonal and spatial effect was observed in the robustness of genders and stages of sea lice, which suggest that mixing different genders and stages of lice within a single bioassay may result in pertinent information being overlooked. Poor survival of adult female lice in bioassays, particularly during May/June, indicates it may be prudent to consider excluding this stage from bioassays conducted at certain times of the year. This work demonstrates that fixed-dose bioassays can be a valuable technique in detecting reduced sensitivity in sea lice populations with varying degrees of susceptibility to emamectin benzoate treatments. © 2013 Blackwell Publishing Ltd.

  5. Detecting the heavy metal tolerance level in ectomycorrhizal fungi in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Ray, P.; Tiwari, R.; Reddy, U.G.; Adholeya, A. [India Habitat Center, New Delhi (India). Energy & Resources Institute

    2005-04-01

    Eight isolates of ectomycorrhizal fungi namely, Laccaria fraterna (EM-1083), Laccaria laccata (EM-1191), Pisolithus tinctorius (EM-1081), Pisolithus tinctorius (EM-1293), Scleroderma cepa (EM-1233), Scleroderma flavidum (EM-1235), Scleroderma verucosum, (EM-1283) and Hysterangium incarceratum (EM-1185) were grown on specially designed cocktail media prepared by adding various concentrations of different heavy metals namely Al, As, Cd, Cr, Ni and Pb. The heavy metals were selected keeping in view their relative abundance in coal ash and potential toxicity. The fungal isolates were grown on such designed cocktail media. The colony diameter was used for the measurement of the fungal growth. Total heavy metal accumulated in the mycelia was assayed by atomic absorption spectrophotometry. In relation to metal tolerance ability in general, Hysterangium incarceratum (EM-1185) showed maximum tolerance with respect to growth, Laccaria fraterna (EM-1083) and Pisolithus tinctorius (EM-1293) also showed considerable tolerance to the heavy metals tested. In relation to metal uptake in particular, Pisolithus tinctorius (EM-1293), has reported maximum uptake of Al (34642.58 ppm), Cd (302.12 ppm) and Pb (3501.96 ppm). In Laccaria fraterna (EM-1083), As (130.57 ppm) and Cr (402.38 ppm) uptake was recorded maximum; and Hysterangium incarceratum (EM-1185) has recorded maximum Ni (2648.59 ppm) uptake among the three suitable isolates documented here.

  6. Assessment of diurnal systemic dose of agrochemicals in regulatory toxicity testing--an integrated approach without additional animal use.

    Science.gov (United States)

    Saghir, Shakil A; Bartels, Michael J; Rick, David L; McCoy, Alene T; Rasoulpour, Reza J; Ellis-Hutchings, Robert G; Sue Marty, M; Terry, Claire; Bailey, Jason P; Billington, Richard; Bus, James S

    2012-07-01

    Integrated toxicokinetics (TK) data provide information on the rate, extent and duration of systemic exposure across doses, species, strains, gender, and life stages within a toxicology program. While routine for pharmaceuticals, TK assessments of non-pharmaceuticals are still relatively rare, and have never before been included in a full range of guideline studies for a new agrochemical. In order to better understand the relationship between diurnal systemic dose (AUC(24h)) and toxicity of agrochemicals, TK analyses in the study animals is now included in all short- (excluding acute), medium- and long-term guideline mammalian toxicity studies including reproduction/developmental tests. This paper describes a detailed procedure for the implementation of TK in short-, medium- and long-term regulatory toxicity studies, without the use of satellite animals, conducted on three agrochemicals (X11422208, 2,4-D and X574175). In these studies, kinetically-derived maximum doses (KMD) from short-term studies instead of, or along with, maximum tolerated doses (MTD) were used for the selection of the high dose in subsequent longer-term studies. In addition to leveraging TK data to guide dose level selection, the integrated program was also used to select the most appropriate method of oral administration (i.e., gavage versus dietary) of test materials for rat and rabbit developmental toxicity studies. The integrated TK data obtained across toxicity studies (without the use of additional/satellite animals) provided data critical to understanding differences in response across doses, species, strains, sexes, and life stages. Such data should also be useful in mode of action studies and to improve human risk assessments. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Tissue tolerance under the combination treatment of maxillary cancer

    International Nuclear Information System (INIS)

    Egawa, Jun; Ono, Isamu; Suzuki, Kunio; Takeda, Chisato; Ebihara, Satoshi.

    1977-01-01

    The tissue tolerance doses of the maxillary sinus structures were estimated when they were subjected to treatment for maxillary cancer by the usual combination of surgery, radiotherapy and regional arterial infusion of 5-fluorouracil. Equivalent single dose calculation was applied with irreversible tissue damage as an indicator. The retardation of epithelialization of the maxillary sinus operated upon appeared to be correlated with the dose delivered. The study indicated that 2,200 rad expressed by equivalent single dose is a safe dose level for sufficient epithelialization. The safety dose level for the bony structure, exposed by surgery, seemed to be at 1,800 rad. (auth.)

  8. Considerations on absorbed dose estimates based on different β-dose point kernels in internal dosimetry

    International Nuclear Information System (INIS)

    Uchida, Isao; Yamada, Yasuhiko; Yamashita, Takashi; Okigaki, Shigeyasu; Oyamada, Hiyoshimaru; Ito, Akira.

    1995-01-01

    In radiotherapy with radiopharmaceuticals, more accurate estimates of the three-dimensional (3-D) distribution of absorbed dose is important in specifying the activity to be administered to patients to deliver a prescribed absorbed dose to target volumes without exceeding the toxicity limit of normal tissues in the body. A calculation algorithm for the purpose has already been developed by the authors. An accurate 3-D distribution of absorbed dose based on the algorithm is given by convolution of the 3-D dose matrix for a unit cubic voxel containing unit cumulated activity, which is obtained by transforming a dose point kernel into a 3-D cubic dose matrix, with the 3-D cumulated activity distribution given by the same voxel size. However, beta-dose point kernels affecting accurate estimates of the 3-D absorbed dose distribution have been different among the investigators. The purpose of this study is to elucidate how different beta-dose point kernels in water influence on the estimates of the absorbed dose distribution due to the dose point kernel convolution method by the authors. Computer simulations were performed using the MIRD thyroid and lung phantoms under assumption of uniform activity distribution of 32 P. Using beta-dose point kernels derived from Monte Carlo simulations (EGS-4 or ACCEPT computer code), the differences among their point kernels gave little differences for the mean and maximum absorbed dose estimates for the MIRD phantoms used. In the estimates of mean and maximum absorbed doses calculated using different cubic voxel sizes (4x4x4 mm and 8x8x8 mm) for the MIRD thyroid phantom, the maximum absorbed doses for the 4x4x4 mm-voxel were estimated approximately 7% greater than the cases of the 8x8x8 mm-voxel. They were found in every beta-dose point kernel used in this study. On the other hand, the percentage difference of the mean absorbed doses in the both voxel sizes for each beta-dose point kernel was less than approximately 0.6%. (author)

  9. Pharmacokinetics of surotomycin from phase 1 single and multiple ascending dose studies in healthy volunteers.

    Science.gov (United States)

    Chandorkar, Gurudatt; Zhan, Qiao; Donovan, Julie; Rege, Shruta; Patino, Hernando

    2017-03-28

    Surotomycin, a novel, orally administered, cyclic, lipopeptide antibacterial in development for the treatment of Clostridium difficile-associated diarrhea, has demonstrated minimal intestinal absorption in animal models. Safety, tolerability, and plasma pharmacokinetics of single and multiple ascending oral doses (SAD/MAD) of surotomycin in healthy volunteers were characterized in two randomized, double-blind, placebo-controlled, phase 1 studies. Participants were sequentially enrolled into one of four SAD (500, 1000, 2000, 4000 mg surotomycin) or three MAD (250, 500, 1000 mg surotomycin twice/day for 14 days) cohorts. Ten subjects were randomized 4:1 into each cohort to receive surotomycin or placebo. Surotomycin plasma concentrations rose as dose increased (maximum plasma concentration [C max ]: 10.5, 21.5, 66.6, and 86.7 ng/mL). Systemic levels were generally low, with peak median surotomycin plasma concentrations observed 6-12 h after the first dose. In the MAD study, surotomycin plasma concentrations were higher on day 14 (C max : 25.5, 37.6, and 93.5 ng/mL) than on day 1 (C max : 6.8, 11.0, and 21.1 ng/mL for increasing doses), indicating accumulation. In the SAD study, <0.01% of the administered dose was recovered in urine. Mean surotomycin stool concentration from the 1000 mg MAD cohort was 6394 μg/g on day 5. Both cohorts were well tolerated with all adverse events reported as mild to moderate. Both SAD and MAD studies of surotomycin demonstrated minimal systemic exposure, with feces the primary route of elimination following oral administration; consistent with observations with similar compounds, such as fidaxomicin. Results of these phase 1 studies support the continued clinical development of surotomycin for the treatment of Clostridium difficile-associated diarrhea. NCT02835118 and NCT02835105 . Retrospectively registered, July 13 2016.

  10. Hemodynamic mechanisms underlying the incomplete tolerance to caffeine's pressor effects.

    Science.gov (United States)

    Farag, Noha H; Vincent, Andrea S; McKey, Barbara S; Whitsett, Thomas L; Lovallo, William R

    2005-06-01

    Blood pressure (BP) and cardiovascular hemodynamics were assessed at baseline and after caffeine administration in a 4-week, placebo-controlled, double-blind, randomized, crossover trial of caffeine tolerance formation. Half of the subjects developed tolerance to the pressor effect of caffeine, whereas the other half continued to show increases in BP after caffeine ingestion (F = 16.7, p <0.0001). In the subjects who did not develop tolerance, peripheral resistance increased incrementally as the daily dose of caffeine increased (F = 2.8, p = 0.05).

  11. Temperature tolerance of young-of-the-year cisco, Coregonus artedii

    Science.gov (United States)

    Edsall, Thomas A.; Colby, Peter J.

    1970-01-01

    Young-of-the-year ciscoes (Coregonus artedii) acclimated to 2, 5, 10, 20 and 25 C and tested for tolerance to high and low temperatures provide the first detailed description of the thermal tolerance of coregonids in North America. The upper ultimate lethal temperature of the young ciscoes was 26 C (6 C higher than the maximum sustained temperature tolerated by adult ciscoes in nature) and the ultimate lower lethal temperature approached 0 C (near that commonly tolerated in nature by adult ciscoes). The temperature of 26 C is slightly higher than the lowest ultimate upper lethal temperature recorded for North American freshwater fishes; however, published information on the depth distributions of fishes in the Great Lakes suggests that some of the other coregonids may be less tolerant of high temperatures than the cisco.

  12. Georgia fishery study: implications for dose calculations

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1983-01-01

    Fish consumption will contribute a major portion of the estimated individual and population doses from L-Reactor liquid releases and Cs-137 remobilization in Steel Creek. It is therefore important that the values for fish consumption used in dose calculations be as realistic as possible. Since publication of the L-Reactor Environmental Information Document (EID), data have become available on sport fishing in the Savannah River. These data provide SRP with site-specific sport fish harvest and consumption values for use in dose calculations. The Georgia fishery data support the total population fish consumption and calculated dose reported in the EID. The data indicate, however, that both the EID average and maximum individual fish consumption have been underestimated, although each to a different degree. The average fish consumption value used in the EID is approximately 3% below the lower limit of the fish consumption range calculated using the Georgia data. A fish consumption value of 11.3 kg/yr should be used to recalculate dose to the average individual from L-Reactor restart. Maximum fish consumption in the EID has been underestimated by approximately 60%, and doses to the maximum individual should also be recalculated. Future dose calculations should utilize an average fish consumption value of 11.3 kg/yr, and a maximum fish consumption value of 34 kg/yr

  13. Fault tolerance based on serial communication of FPGA

    International Nuclear Information System (INIS)

    Peng Jing; Fang Zongliang; Xu Quanzhou; Hu Jiewei; Ma Guizhen

    2012-01-01

    There maybe appear mistake in serial communication. This paper was described the intellectual detector of γ dose ratemeter communication with FPGA. The software of FPGA designed the code about fault tolerance, prevented mistake effectively. (authors)

  14. The DESCARTES-Nantes survey of kidney transplant recipients displaying clinical operational tolerance identifies 35 new tolerant patients and 34 almost tolerant patients.

    Science.gov (United States)

    Massart, Annick; Pallier, Annaïck; Pascual, Julio; Viklicky, Ondrej; Budde, Klemens; Spasovski, Goce; Klinger, Marian; Sever, Mehmet Sukru; Sørensen, Søren Schwartz; Hadaya, Karine; Oberbauer, Rainer; Dudley, Christopher; De Fijter, Johan W; Yussim, Alexander; Hazzan, Marc; Wekerle, Thomas; Berglund, David; De Biase, Consuelo; Pérez-Sáez, María José; Mühlfeld, Anja; Orlando, Giuseppe; Clemente, Katia; Lai, Quirino; Pisani, Francesco; Kandus, Aljosa; Baas, Marije; Bemelman, Frederike; Ponikvar, Jadranka Buturovic; Mazouz, Hakim; Stratta, Piero; Subra, Jean-François; Villemain, Florence; Hoitsma, Andries; Braun, Laura; Cantarell, Maria Carmen; Colak, Hulya; Courtney, Aisling; Frasca, Giovanni Maria; Howse, Matthew; Naesens, Maarten; Reischig, Tomas; Serón, Daniel; Seyahi, Nurhan; Tugmen, Cem; Alonso Hernandez, Angel; Beňa, Luboslav; Biancone, Luigi; Cuna, Vania; Díaz-Corte, Carmen; Dufay, Alexandre; Gaasbeek, André; Garnier, Arnaud; Gatault, Philippe; Gentil Govantes, Miguel Angel; Glowacki, François; Gross, Oliver; Hurault de Ligny, Bruno; Huynh-Do, Uyen; Janbon, Bénédicte; Jiménez Del Cerro, Luis Antonio; Keller, Frieder; La Manna, Gaetano; Lauzurica, Ricardo; Le Monies De Sagazan, Hervé; Thaiss, Friedrich; Legendre, Christophe; Martin, Séverine; Moal, Marie-Christine; Noël, Christian; Pillebout, Evangeline; Piredda, Gian Benedetto; Puga, Ana Ramírez; Sulowicz, Wladyslaw; Tuglular, Serhan; Prokopova, Michaela; Chesneau, Mélanie; Le Moine, Alain; Guérif, Pierrick; Soulillou, Jean-Paul; Abramowicz, Marc; Giral, Magali; Racapé, Judith; Maggiore, Umberto; Brouard, Sophie; Abramowicz, Daniel

    2016-06-01

    Kidney recipients maintaining a prolonged allograft survival in the absence of immunosuppressive drugs and without evidence of rejection are supposed to be exceptional. The ERA-EDTA-DESCARTES working group together with Nantes University launched a European-wide survey to identify new patients, describe them and estimate their frequency for the first time. Seventeen coordinators distributed a questionnaire in 256 transplant centres and 28 countries in order to report as many 'operationally tolerant' patients (TOL; defined as having a serum creatinine <1.7 mg/dL and proteinuria <1 g/day or g/g creatinine despite at least 1 year without any immunosuppressive drug) and 'almost tolerant' patients (minimally immunosuppressed patients (MIS) receiving low-dose steroids) as possible. We reported their number and the total number of kidney transplants performed at each centre to calculate their frequency. One hundred and forty-seven questionnaires were returned and we identified 66 TOL (61 with complete data) and 34 MIS patients. Of the 61 TOL patients, 26 were previously described by the Nantes group and 35 new patients are presented here. Most of them were noncompliant patients. At data collection, 31/35 patients were alive and 22/31 still operationally tolerant. For the remaining 9/31, 2 were restarted on immunosuppressive drugs and 7 had rising creatinine of whom 3 resumed dialysis. Considering all patients, 10-year death-censored graft survival post-immunosuppression weaning reached 85% in TOL patients and 100% in MIS patients. With 218 913 kidney recipients surveyed, cumulative incidences of operational tolerance and almost tolerance were estimated at 3 and 1.5 per 10 000 kidney recipients, respectively. In kidney transplantation, operational tolerance and almost tolerance are infrequent findings associated with excellent long-term death-censored graft survival. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  15. Low-dose oral tolerance due to antigen in the diet suppresses differentially the cholera toxin-adjuvantized IgE, IgA and IgG response

    DEFF Research Database (Denmark)

    Christensen, Hanne Risager; Kjær, Tanja; Frøkiær, Hanne

    2003-01-01

    Background: Cholera toxin (CT) is used as a mucosal adjuvant amongst other applications for studying food allergy because oral administration of antigen with CT induces an antigen-specific type 2 response, including IgE and IgA production. Priorly established oral tolerance due to antigen...... soy-trypsin inhibitor (KSTI) (F0 mice) and mice fed a soy-free diet (F2 mice) were orally immunized with KSTI and CT. KSTI-specific serum IgG1, IgG2a, IgA and IgE and fecal IgA were monitored. KSTI-stimulated cell proliferation and interleukin (IL)-6 production were determined. Results: The anti...... immunizations. However, cell proliferation and IL-6 production were clearly suppressed even after five immunizations. Conclusions: Priorly established low-dose oral tolerance considerably suppressed the CT-adjuvantized KSTI-specific IgE, IgA and cellular immune response but only weakly and transiently the Ig...

  16. Relative bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension.

    Science.gov (United States)

    Clemens, Pamela L; Cloyd, James C; Kriel, Robert L; Remmel, Rory P

    2007-01-01

    Maintenance of effective drug concentrations is essential for adequate treatment of epilepsy. Some antiepileptic drugs can be successfully administered rectally when the oral route of administration is temporarily unavailable. Oxcarbazepine is a newer antiepileptic drug that is rapidly converted to a monohydroxy derivative, the active compound. This study aimed to characterise the bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension using a randomised, crossover design in ten healthy volunteers. Two subjects received 300 mg doses of oxcarbazepine suspension via rectal and oral routes and eight received 450 mg doses. A washout period of at least 2 weeks elapsed between doses. The rectal dose was diluted 1:1 with water. Blood samples and urine were collected for 72 hours post-dose. Adverse effects were assessed at each blood collection time-point using a self-administered questionnaire. Plasma was assayed for oxcarbazepine and monohydroxy derivative; urine was assayed for monohydroxy derivative and monohydroxy derivative-glucuronide. Maximum plasma concentration (C(max)) and time to reach C(max) (t(max)) were obtained directly from the plasma concentration-time curves. The areas under the concentration-time curve (AUCs) were determined via non-compartmental analysis. Relative bioavailability was calculated and the C(max) and AUCs were compared using Wilcoxon signed-rank tests. Mean relative bioavailability calculated from plasma AUCs was 8.3% (SD 5.5%) for the monohydroxy derivative and 10.8% (SD 7.3%) for oxcarbazepine. Oxcarbazepine and monohydroxy derivative C(max) and AUC values were significantly lower following rectal administration (p effects were headache and fatigue with no discernible differences between routes. Monohydroxy derivative bioavailability following rectal administration of oxcarbazepine suspension is significantly lower than following oral administration, most likely because of poor oxcarbazepine water

  17. Dose-to-medium vs. dose-to-water: Dosimetric evaluation of dose reporting modes in Acuros XB for prostate, lung and breast cancer

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-12-01

    Full Text Available Purpose: Acuros XB (AXB dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS. The AXB can report the absorbed dose in two modes: dose-to-water (Dw and dose-to-medium (Dm. The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four groups of patients (prostate cancer, stereotactic body radiation therapy (SBRT lung cancer, left breast cancer, and right breast cancer were selected for this study, and each group consisted of 5 cases. The treatment plans of all cases were generated in the Eclipse TPS. For each case, treatment plans were computed using AXB_Dw and AXB_Dm for identical beam arrangements. Dosimetric evaluation was done by comparing various dosimetric parameters in the AXB_Dw plans with that of AXB_Dm plans for the corresponding patient case. Results: For the prostate cancer, the mean planning target volume (PTV dose in the AXB_Dw plans was higher by up to 1.0%, but the mean PTV dose was within ±0.3% for the SBRT lung cancer. The analysis of organs at risk (OAR results in the prostate cancer showed that AXB_Dw plans consistently produced higher values for the bladder and femoral heads but not for the rectum. In the case of SBRT lung cancer, a clear trend was seen for the heart mean dose and spinal cord maximum dose, with AXB_Dw plans producing higher values than the AXB_Dm plans. However, the difference in the lung doses between the AXB_Dm and AXB_Dw plans did not always produce a clear trend, with difference ranged from -1.4% to 2.9%. For both the left and right breast cancer, the AXB_Dm plans produced higher maximum dose to the PTV for all cases. The evaluation of the maximum dose to the skin showed higher values in the AXB_Dm plans for all 5 left breast cancer cases, whereas only 2 cases had higher maximum dose to the skin in the AXB_Dm plans for the right breast cancer

  18. 77 FR 25904 - Acequinocyl; Pesticide Tolerances

    Science.gov (United States)

    2012-05-02

    ... for parental males was 58.9/69.2 mg/kg/ day, based on hemorrhagic effects. The offspring systemic... effects because they were observed at very high doses and in the presence of more severe systemic effects... to enforce the tolerance expression. The methods may be requested from: Chief, Analytical Chemistry...

  19. Modeling Tolerance Development for the Effect on Heart Rate of the Selective S1P1 Receptor Modulator Ponesimod.

    Science.gov (United States)

    Lott, Dominik; Lehr, Thorsten; Dingemanse, Jasper; Krause, Andreas

    2017-09-15

    Ponesimod is a selective sphingosine-1-phosphate-1 (S1P 1 ) receptor modulator currently under investigation for the treatment of multiple sclerosis. S1P receptor modulators reduce heart rate following treatment initiation. This effect disappears with repeated dosing, enabling development of innovative uptitration regimens to optimize patient safety. There are currently no published pharmacokinetic/pharmacodynamic models describing the heart rate reduction of S1P receptor modulators in humans. The model developed here provides quantification of this effect for ponesimod. A direct-effect I max model with estimated maximum reduction of 45%, tolerance development, and circadian variation best described this effect. The pooled data from nine clinical studies enabled characterization of interindividual variability. The model was used to simulate different treatment regimens to compare the effect of high initial doses vs. gradual uptitration with respect to the occurrence of bradycardia. The results indicate a better safety profile when using gradual uptitration. The model allows studying dosing regimens not clinically tested in silico. © 2017 American Society for Clinical Pharmacology and Therapeutics.

  20. A theory of drug tolerance and dependence I: a conceptual analysis.

    Science.gov (United States)

    Peper, Abraham

    2004-08-21

    A mathematical model of drug tolerance and its underlying theory is presented. The model extends a first approach, published previously. The model is essentially more complex than the generally used model of homeostasis, which is demonstrated to fail in describing tolerance development to repeated drug administrations. The model assumes the development of tolerance to a repeatedly administered drug to be the result of a regulated adaptive process. The oral detection and analysis of exogenous substances is proposed to be the primary stimulus for the mechanism of drug tolerance. Anticipation and environmental cues are in the model considered secondary stimuli, becoming primary only in dependence and addiction or when the drug administration bypasses the natural-oral-route, as is the case when drugs are administered intravenously. The model considers adaptation to the effect of a drug and adaptation to the interval between drug taking autonomous tolerance processes. Simulations with the mathematical model demonstrate the model's behavior to be consistent with important characteristics of the development of tolerance to repeatedly administered drugs: the gradual decrease in drug effect when tolerance develops, the high sensitivity to small changes in drug dose, the rebound phenomenon and the large reactions following withdrawal in dependence. The mathematical model verifies the proposed theory and provides a basis for the implementation of mathematical models of specific physiological processes. In addition, it establishes a relation between the drug dose at any moment, and the resulting drug effect and relates the magnitude of the reactions following withdrawal to the rate of tolerance and other parameters involved in the tolerance process. The present paper analyses the concept behind the model. The next paper discusses the mathematical model.

  1. External Beam Radiotherapy of Recurrent Glioma: Radiation Tolerance of the Human Brain

    Energy Technology Data Exchange (ETDEWEB)

    Sminia, Peter, E-mail: p.sminia@vumc.nl [Department of Radiation Oncology, Radiobiology Section, VU University Medical Center, De Boelelaan 1117, P.O. Box 7057, Amsterdam (Netherlands); Mayer, Ramona [EBG MedAustron GmbH., Viktor Kaplan-Strasse 2, A-2700, Wiener Neustadt (Austria)

    2012-04-05

    Malignant gliomas relapse in close proximity to the resection site, which is the postoperatively irradiated volume. Studies on re-irradiation of glioma were examined regarding radiation-induced late adverse effects (i.e., brain tissue necrosis), to obtain information on the tolerance dose and treatment volume of normal human brain tissue. The studies were analyzed using the linear-quadratic model to express the re-irradiation tolerance in cumulative equivalent total doses when applied in 2 Gy fractions (EQD2{sub cumulative}). Analysis shows that the EQD2{sub cumulative} increases from conventional re-irradiation series to fractionated stereotactic radiotherapy (FSRT) to LINAC-based stereotactic radiosurgery (SRS). The mean time interval between primary radiotherapy and the re-irradiation course was shortened from 30 months for conventional re-irradiation to 17 and 10 months for FSRT and SRS, respectively. Following conventional re-irradiation, radiation-induced normal brain tissue necrosis occurred beyond an EQD2{sub cumulative} around 100 Gy. With increasing conformality of therapy, the smaller the treatment volume is, the higher the radiation dose that can be tolerated. Despite the dose escalation, no increase in late normal tissue toxicity was reported. On basis of our analysis, the use of particle therapy in the treatment of recurrent gliomas, because of the optimized physical dose distribution in the tumour and surrounding healthy brain tissue, should be considered for future clinical trials.

  2. External Beam Radiotherapy of Recurrent Glioma: Radiation Tolerance of the Human Brain

    Directory of Open Access Journals (Sweden)

    Peter Sminia

    2012-04-01

    Full Text Available Malignant gliomas relapse in close proximity to the resection site, which is the postoperatively irradiated volume. Studies on re-irradiation of glioma were examined regarding radiation-induced late adverse effects (i.e., brain tissue necrosis, to obtain information on the tolerance dose and treatment volume of normal human brain tissue. The studies were analyzed using the linear-quadratic model to express the re-irradiation tolerance in cumulative equivalent total doses when applied in 2 Gy fractions (EQD2cumulative. Analysis shows that the EQD2cumulative increases from conventional re-irradiation series to fractionated stereotactic radiotherapy (FSRT to LINAC-based stereotactic radiosurgery (SRS. The mean time interval between primary radiotherapy and the re-irradiation course was shortened from 30 months for conventional re-irradiation to 17 and 10 months for FSRT and SRS, respectively. Following conventional re-irradiation, radiation-induced normal brain tissue necrosis occurred beyond an EQD2cumulative around 100 Gy. With increasing conformality of therapy, the smaller the treatment volume is, the higher the radiation dose that can be tolerated. Despite the dose escalation, no increase in late normal tissue toxicity was reported. On basis of our analysis, the use of particle therapy in the treatment of recurrent gliomas, because of the optimized physical dose distribution in the tumour and surrounding healthy brain tissue, should be considered for future clinical trials.

  3. Limits of dose escalation in lung cancer: a dose-volume histogram analysis comparing coplanar and non-coplanar techniques

    Energy Technology Data Exchange (ETDEWEB)

    Derycke, S; Van Duyse, B; Schelfhout, J; De Neve, W

    1995-12-01

    To evaluate the feasibility of dose escalation in radiotherapy of inoperable lung cancer, a dose-volume histogram analysis was performed comparing standard coplanar (2D) with non-coplanar (3D) beam arrangements on a non-selected group of 20 patients planned by Sherouse`s GRATISTM 3D-planning system. Serial CT-scanning was performed and 2 Target Volumes (Tvs) were defined. Gross Tumor Volume (GTV) defined a high-dose Target Volume (TV-1). GTV plus location of node stations with > 10% probability of invasion (Minet et al.) defined an intermediate-dose Target Volume (TV-2). However, nodal regions which are incompatible with cure were excluded from TV-2. These are ATS-regions 1, 8, 9 and 14 all left and right as well as heterolateral regions. For 3D-planning, Beam`s Eye View selected (by an experienced planner) beam arrangements were optimised using Superdot, a method of target dose-gradient annihilation developed by Sherouse. A second 3D-planning was performed using 4 beam incidences with maximal angular separation. The linac`s isocenter for the optimal arrangement was located at the geometrical center of gravity of a tetraheder, the tetraheder`s comers being the consecutive positions of the virtual source. This ideal beam arrangement was approximated as close as possible, taking into account technical limitations (patient-couch-gantry collisions). Criteria for tolerance were met if no points inside the spinal cord exceeded 50 Gy and if at least 50% of the lung volume received less than 20Gy. If dose regions below 50 Gy were judged acceptable at TV-2, 2D- as well as 3D-plans allow safe escalation to 80 Gy at TV-1. When TV-2 needed to be encompassed by isodose surfaces exceeding 50Gy, 3D-plans were necessary to limit dose at the spinal cord below tolerance. For large TVs dose is limited by lung tolerance for 3D-plans. An analysis (including NTCP-TCP as cost functions) of rival 3D-plans is being performed.

  4. Analysis and optimization of fault-tolerant embedded systems with hardened processors

    DEFF Research Database (Denmark)

    Izosimov, Viacheslav; Polian, Ilia; Pop, Paul

    2009-01-01

    In this paper we propose an approach to the design optimization of fault-tolerant hard real-time embedded systems, which combines hardware and software fault tolerance techniques. We trade-off between selective hardening in hardware and process reexecution in software to provide the required levels...... of fault tolerance against transient faults with the lowest-possible system costs. We propose a system failure probability (SFP) analysis that connects the hardening level with the maximum number of reexecutions in software. We present design optimization heuristics, to select the fault......-tolerant architecture and decide process mapping such that the system cost is minimized, deadlines are satisfied, and the reliability requirements are fulfilled....

  5. Phase I study of twice-weekly gemcitabine and concomitant external-beam radiotherapy in patients with adenocarcinoma of the pancreas

    International Nuclear Information System (INIS)

    Pipas, J. Marc; Mitchell, Sandra E.; Barth, Richard J.; Vera-Gimon, Raul; Rathmann, Joerg; Meyer, Louise P.; Wagman, Richard S.; Lewis, Lionel D.; McDonnell, Carol; Colacchio, Thomas A.; Perez, Raymond P.

    2001-01-01

    Purpose: To determine the maximum tolerated dose and dose-limiting toxicity associated with twice-weekly gemcitabine and concomitant external-beam radiotherapy in patients with adenocarcinoma of the pancreas. Methods and Materials: Twenty-one patients with biopsy-proven adenocarcinoma of the pancreas were treated with external-beam radiotherapy to a dose of 50.4 Gy in 28 fractions, concurrent with gemcitabine, infused over 30 min before irradiation on a Monday and Thursday schedule. The dose of gemcitabine was escalated in 5 cohorts of 3-6 patients each. Initial gemcitabine dose was 10 mg/m 2 , with dose escalation until dose-limiting toxicity was observed. Results: The maximum tolerated dose of gemcitabine was 50 mg/m 2 , when given in a twice-weekly schedule with radiation. Dose-limiting toxicity was seen in 2 patients at 60 mg/m 2 , and consisted of severe upper gastrointestinal bleeding approximately 1 month after completion of treatment. Six patients had radiographic evidence of response to treatment, and 5 of these underwent complete surgical resection. Three patients who underwent complete resection had been deemed to have unresectable tumors before enrollment on trial. Four patients are alive, including 2 without evidence of disease more than 1 year after resection. Conclusion: The combination of external-beam radiation and twice-weekly gemcitabine at a dose of 50 mg/m 2 is well tolerated and shows promising activity for the treatment of pancreatic cancer. Our data suggest a higher maximum tolerated dose and different dose-limiting toxicity than previously reported. Further investigation of this regimen is warranted

  6. Process variation in electron beam sterilization

    International Nuclear Information System (INIS)

    Beck, Jeffrey A.

    2012-01-01

    The qualification and control of electron beam sterilization can be improved by the application of proven statistical analysis techniques such as Analysis of Variance (ANOVA) and Statistical Tolerance Limits. These statistical techniques can be useful tools in: •Locating and quantifying the minimum and maximum absorbed dose in a product. •Estimating the expected process maximum dose, given a minimum sterilizing dose. •Setting a process minimum dose target, based on an allowance for random measurement and process variation. •Determining the dose relationship between a reference dosimeter and process minimum and maximum doses. This study investigates and demonstrates the application of these tools in qualifying electron beam sterilization, and compares the conclusions obtained with those obtained using practices recommended in Guide for Process Control in Radiation Sterilization. The study supports the following conclusions for electron beam processes: 1.ANOVA is a more effective tool for evaluating the equivalency of absorbed doses than methods suggested in . 2.Process limits computed using statistical tolerance limits more accurately reflect actual process variability than the AAMI method, which applies +/−2 sample standard deviations (s) regardless of sample size. 3.The use of reference dose ratios lends itself to qualification using statistical tolerance limits. The current AAMI recommended approach may result in an overly optimistic estimate of the reference dose adjustment factor, as it is based on application of +/−2(s) tolerances regardless of sample size.

  7. Determination of the maximum individual dose exposure resulting from a hypothetical LEU plate-melt accident

    International Nuclear Information System (INIS)

    Abdelhady, Amr

    2013-01-01

    Highlights: ► Studying the radioactive release results from hypothetical plate-melt accident. ► Hotspot code was used to study the dose distributions around the reactor. ► A 90% decrease in the received dose in proper operation of filtration. ► The received dose is lower than the annual permissible dose after filtration. - Abstract: The objective of this study was to provide an estimate of the potential impact of accidental radioactive release from the testing cell of the Egyptian second research reactor ETRR-2 on the dose level of public around the reactor. The assessment was performed for two cases: an evaluation of the impact that accidental release has on the dose that would be received by public around the reactor in case of proper operation of testing cell filtration system; and an assessment of the potential dose in case of loss of testing cell filtration system. The results show that the filtration system has a great role in decreasing the dose received by an individual located outside the reactor to a dose level lower than the annual permissible dose

  8. Gemcitabine and paclitaxel associated pneumonitis in non-small cell lung cancer: report of a phase I/II dose-escalating study.

    Science.gov (United States)

    Thomas, A L; Cox, G; Sharma, R A; Steward, W P; Shields, F; Jeyapalan, K; Muller, S; O'Byrne, K J

    2000-12-01

    The aim of this phase I/II dose escalating study was to establish the maximum tolerated dose (MTD) of gemcitabine and paclitaxel given in combination in non-small cell lung cancer (NSCLC). 12 patients with stage IIIB and IV NSCLC received paclitaxel administered intravenously over 1 h followed by gemcitabine given over 30 min on days 1, 8 and 15 every 28 days. Pneumonitis was the principal side-effect observed with 4 patients affected. Of these, 1 experienced grade 3 toxicity after one cycle of treatment and the others had grade 2 toxicity. All 4 cases responded to prednisolone. No other significant toxicities were observed. Of the 8 evaluable patients, 3 had a partial response and 2 had minor responses. The study was discontinued due to this dose-limiting toxicity. The combination of paclitaxel and gemcitabine shows promising antitumour activity in NSCLC, however, this treatment schedule may predispose to pneumonitis.

  9. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  10. Long-term tolerance and outcomes for dose escalation in early salvage post-prostatectomy radiation therapy

    International Nuclear Information System (INIS)

    Safdieh, Joseph; Schwartz, David; Weiner, Joseph; Weiss, Jeffrey P.; Madeb, Isaac; Rotman, Marvin; Schreiber, David; Rineer, Justin

    2014-01-01

    To study the long-term outcomes and tolerance in our patients who received dose escalated radiotherapy in the early salvage post-prostatectomy setting. The medical records of 54 consecutive patients who underwent radical prostatectomy subsequently followed by salvage radiation therapy (SRT) to the prostate bed between 2003-2010 were analyzed. Patients included were required to have a pre-radiation prostate specific antigen level (PSA) of 2 ng/mL or less. The median SRT dose was 70.2 Gy. Biochemical failure after salvage radiation was defined as a PSA level >0.2 ng/mL. Biochemical control and survival endpoints were analyzed using the Kaplan-Meier method. Univariate and multivariate Cox regression analysis were used to identify the potential impact of confounding factors on outcomes. The median pre-SRT PSA was 0.45 ng/mL and the median follow-up time was 71 months. The 4- and 7-year actuarial biochemical control rates were 75.7% and 63.2%, respectively. The actuarial 4- and 7-year distant metastasis-free survival was 93.7% and 87.0%, respectively, and the actuarial 7-year prostate cancer specific survival was 94.9%. Grade 3 late genitourinary toxicity developed in 14 patients (25.9%), while grade 4 late genitourinary toxicity developed in 2 patients (3.7%). Grade 3 late gastrointestinal toxicity developed in 1 patient (1.9%), and grade 4 late gastrointestinal toxicity developed in 1 patient (1.9%). In this series with long-term follow-up, early SRT provided outcomes and toxicity profiles similar to those reported from the three major randomized trials studying adjuvant radiation therapy.

  11. Heat tolerance in wheat

    DEFF Research Database (Denmark)

    Sharma, Dew Kumari

    As a consequence of global climate change, heat stress together with other abiotic stresses will remain an important determinant of future food security. Wheat (Triticum aestivum L.) is the third most important crop of the world feeding one third of the world population. Being a crop of temperate...... climate, wheat is sensitive to heat stress. We need to understand how our crops will perform in these changing climatic conditions and how we can develop varieties, which are more tolerant. The PhD study focussed on understanding heat tolerance in wheat with a combined approach of plant physiology...... and quantitative genetics in particular, plant phenotyping based quantitative trait loci (QTL) discovery for a physiological trait under heat stress. Chlorophyll a fluorescence trait, Fv/Fm was used as a phenotyping tool, as it reflects the effect of heat stress on maximum photochemical efficiency of photosystem...

  12. Single-dose and multiple-dose pharmacokinetics and dose proportionality of intravenous and intramuscular HPβCD-diclofenac (Dyloject) compared with other diclofenac formulations.

    Science.gov (United States)

    Mermelstein, Fred; Hamilton, Douglas A; Wright, Curtis; Lacouture, Peter G; Ramaiya, Atulkumar; Carr, Daniel B

    2013-10-01

    To evaluate single- and repeated-dose pharmacokinetics (PK) and dose proportionality of hydroxypropyl-β-cyclodextrin (HPβCD)-diclofenac compared with Voltarol after intravenous (IV) and intramuscular (IM) administration. Study 1: Single-dose randomized four-way crossover study. Study 2: Multiple-dose randomized three-way crossover study. Clinical research center. Healthy adult volunteers. Study 1: Subjects received HPβCD-diclofenac and Voltarol, IV and IM, with a 5-day washout between treatment periods. Study 2: Subjects received two doses of IV HPβCD-diclofenac and oral Cataflam once every 6 hours for four doses with a 48-hour washout period between treatment periods. Study 1: IV HPβCD-diclofenac had a higher peak plasma concentration (Cmax ) and earlier time to reach maximum plasma concentration (Tmax ), but equivalent plasma exposure (area under the curve from time zero to t [AUC0-t ]) to IV Voltarol. The geometric mean ratio of HPβCD-diclofenac (IV) to Voltarol (IV) for AUC0-t was 106.27%. The geometric mean ratio of HPβCD-diclofenac (IM) to Voltarol (IM) for AUC0-t was 110.91%. The geometric mean ratio of HPβCD-diclofenac (IV) to HPβCD-diclofenac (IM) for AUC0-t was 101.25%. The geometric mean ratio of HPβCD-diclofenac (IM) to Voltarol (IV) for AUC0-t was 104.96%. Study 2: Cmax for diclofenac was 2904 and 6031 ng/ml after the first IV dose of 18.75 and 37.5 mg HPβCD-diclofenac, respectively, and was 3090 and 5617 ng/ml after the fourth dose, indicating no accumulation. Plasma exposures to 18.75 mg (866 ng·hour/ml) and 37.5 mg (1843 ng·hour/ml) IV HPβCD-diclofenac bracketed that of oral Cataflam 50 mg (1473 ng·hour/ml). Study 1: Bioavailability in terms of AUC after IV administration was equivalent for HPβCD-diclofenac compared with Voltarol and after IM administration of HPβCD-diclofenac and Voltarol. Bioavailability in terms of AUC after IM administration of HPβCD-diclofenac was equivalent to IV administration of HP

  13. Patient radiation doses from neuroradiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Roman, M J; Abreu-Luis, J; Hernandez-Armas, J [Servicio de Fisica Medica, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain); Prada-Martinez, E [Servicio de Radiodiagnostico, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain)

    2001-03-01

    Following the presentation of radiation-induced deterministic effects by some patients undergoing neuroradiological procedures during successive sessions, such as temporary epilation, in the 'Hospital Universitario de Canarias', measurements were made of dose to patients. The maximum dose-area product measured by ionization chamber during these procedures was 39617 cGy.cm{sup 2} in a diagnostic of aneurysm and the maximum dose to the skin measured by thermoluminescent dosemeters (TLDs) was 462.53 mGy. This can justify certain deterministic effects but it is unlikely that the patients will suffer serious effects from this skin dose. Also, measurements were made of effective dose about two usual procedures, embolisation of tumour und embolisation of aneurysm. These procedures were reproduced with an anthropomorphic phantom Rando and doses were measured with TLDs. Effective doses obtained were 3.79 mSv and 4.11 mSv, respectively. The effective dose valued by the program EFFDOSE was less than values measured with TLDs. (author)

  14. Patient radiation doses from neuroradiology procedures

    International Nuclear Information System (INIS)

    Garcia-Roman, M.J.; Abreu-Luis, J.; Hernandez-Armas, J.; Prada-Martinez, E.

    2001-01-01

    Following the presentation of radiation-induced deterministic effects by some patients undergoing neuroradiological procedures during successive sessions, such as temporary epilation, in the 'Hospital Universitario de Canarias', measurements were made of dose to patients. The maximum dose-area product measured by ionization chamber during these procedures was 39617 cGy.cm 2 in a diagnostic of aneurysm and the maximum dose to the skin measured by thermoluminescent dosemeters (TLDs) was 462.53 mGy. This can justify certain deterministic effects but it is unlikely that the patients will suffer serious effects from this skin dose. Also, measurements were made of effective dose about two usual procedures, embolisation of tumour und embolisation of aneurysm. These procedures were reproduced with an anthropomorphic phantom Rando and doses were measured with TLDs. Effective doses obtained were 3.79 mSv and 4.11 mSv, respectively. The effective dose valued by the program EFFDOSE was less than values measured with TLDs. (author)

  15. Radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Cohnen, M.; Kemper, J.; Moedder, U.; Moebes, O.; Pawelzik, J.

    2002-01-01

    The aim of this study was to compare radiation exposure in panoramic radiography (PR), dental CT, and digital volume tomography (DVT). An anthropomorphic Alderson-Rando phantom and two anatomical head phantoms with thermoluminescent dosimeters fixed at appropriate locations were exposed as in a dental examination. In PR and DVT, standard parameters were used while variables in CT included mA, pitch, and rotation time. Image noise was assessed in dental CT and DVT. Radiation doses to the skin and internal organs within the primary beam and resulting from scatter radiation were measured and expressed as maximum doses in mGy. For PR, DVT, and CT, these maximum doses were 0.65, 4.2, and 23 mGy. In dose-reduced CT protocols, radiation doses ranged from 10.9 to 6.1 mGy. Effective doses calculated on this basis showed values below 0.1 mSv for PR, DVT, and dose-reduced CT. Image noise was similar in DVT and low-dose CT. As radiation exposure and image noise of DVT is similar to low-dose CT, this imaging technique cannot be recommended as a general alternative to replace PR in dental radiology. (orig.)

  16. Phase I dose-finding study of cabazitaxel administered weekly in patients with advanced solid tumours

    International Nuclear Information System (INIS)

    Fumoleau, Pierre; Trigo, Jose Manuel; Isambert, Nicolas; Sémiond, Dorothée; Gupta, Sunil; Campone, Mario

    2013-01-01

    Cabazitaxel is approved in patients with metastatic hormone-refractory prostate cancer previously treated with a docetaxel-containing regimen. This study evaluated a weekly cabazitaxel dosing regimen. Primary objectives were to report dose-limiting toxicities (DLTs) and to determine the maximum tolerated dose (MTD). Efficacy, safety and pharmacokinetics were secondary objectives. Cabazitaxel was administered weekly (1-hour intravenous infusion at 1.5–12 mg/m2 doses) for the first 4 weeks of a 5-week cycle in patients with solid tumours. Monitoring of DLTs was used to determine the MTD and the recommended weekly dose. Thirty-one patients were enrolled. Two of six patients experienced DLTs at 12 mg/m 2 , which was declared the MTD. Gastrointestinal disorders were the most common adverse event. Eight patients developed neutropenia (three ≥ Grade 3); one occurrence of febrile neutropenia was reported. There were two partial responses (in breast cancer) and 13 patients had stable disease (median duration of 3.3 months). Increases in C max and AUC 0–t were dose proportional for the 6–12 mg/m 2 doses. The MTD of weekly cabazitaxel was 12 mg/m 2 and the recommended weekly dose was 10 mg/m 2 . The observed safety profile and antitumour activity of cabazitaxel were consistent with those observed with other taxanes in similar dosing regimens. The study was registered with ClinicalTrials.gov as http://www.clinicaltrials.gov/ct2/show/NCT01755390

  17. The survey of the surface doses of the dental x-ray machines

    International Nuclear Information System (INIS)

    Lee, Jae Seo; Kang, Byung Cheol; Yoon, Suk Ja

    2005-01-01

    The purpose of this study was to investigate variability of doses with same exposure parameters and evaluate radiographic density according to the variability of doses. Twenty-eight MAX-GLS (Shinhung Co, Seoul, Korea), twenty-one D-60-S (DongSeo Med, Seoul, Korea), and eleven REX-601 (Yoshida Dental MFG, Tokyo, Japan) dental x-ray machines were selected for this study. Surface doses were measured under selected combinations of tube voltage, tube current, exposure time, and constant distance 42 cm from the focal spot to the surface of the Multi-O-meter (Unfors Instrument, Billdal, Sweden). Radiographic densities were measured on the films at maximum, minimum and mean surface doses of each brand of x-ray units. With MAX-GLS, the maximum surface doses were thirteen to fourteen times as much as the minimum surfaces doses. With D-60-S, the maximum surface doses were three to eight times as much as the minimum surface doses. With REX-601, the maximum surface doses were six to ten times as much as the minimum surface doses. The differences in radiographic densities among maximum, mean, and minimum doses were significant (p<0.01). The surface exposure doses of each x-ray machine at the same exposure parameters were different within the same manufacturer's machines.

  18. Pharmacokinetic and tolerability of i.m. disodium clodronate 200 mg/lidocaine 1%, given twice monthly, in comparison with i.m. disodium clodronate 100 mg/lidocaine 1%, given weekly, in healthy postmenopausal female patients.

    Science.gov (United States)

    Radicioni, Milko; Cremonesi, Giovanni; Baraldi, Enrica; Leuratti, Chiara; Mariotti, Fabrizia

    2013-04-01

    Clodronate is a bisphosphonate effective in the prevention and treatment of osteoporosis in postmenopausal women. Non-adherence to bisphosphonates, however, is a major issue in clinical practice. Simplifying dose regimens may increase compliance. To assess bioequivalence between an intramuscular (i.m.) clodronate 200 mg/lidocaine 1% twice-a-month formulation and a clodronate 100 mg/lidocaine 1% weekly formulation in 32 postmenopausal women. In this double-blind, randomized, two-way crossover study, test and reference formulations were administered in single dose, with a 2-week wash-out between administrations. The primary endpoint was clodronic acid cumulative excretion in the first 24 hours after injection (Xu0-24h). Cumulative excretion in the 72 hours post-dose (Xu0-72h) and maximum excretion rate (Ratemax) were also evaluated. Bioequivalence was assumed if the 90% confidence intervals (CIs) of the geometric means ratios of the dose-normalized parameters were within the 80.00 - 125.00% range. Local tolerability was evaluated. Mean Xu0-24h values were 114.03 ±23.13 mg and 55.22 ±9.73 mg for clodronate 200 mg and 100 mg. The 90% CIs for dose-normalized Xu0-24h, Xu0-72h and Ratemax ere 95 -110%, 94 -107% and 95 - 113%. Local tolerability of both treatments was good. The differences in pain intensity between formulations were not sigificantly different at most assessment times. Headache was the only treatment-related adverse event. Bioequivalence of the two formulations was confirmed in terms of dose-normalized rate and amount of clodronic acid excretion. This result, together with the favorable tolerability of the novel 200 mg formulation, suggests the possibility of reducing the number of i.m. administrations from once-a-week to twice-a-month.

  19. Bronchial mucosal tolerance following high dose rate endobronchial brachytherapy: clinical and laboratory correlates in late complication assessment of fatal hemoptysis

    International Nuclear Information System (INIS)

    Chen, Y.Y.; McDonald, S.; Nakamura, C.; Philips, A.; Ojomo, Karanita; Hernady, E.; Williams, J. P.; Smudzin, T.; Johnstone, D.; Feins, R.; Speiser, B.L.; Rubin, P.

    1996-01-01

    Purpose: This study reviews treatment related late complications following high dose rate endobronchial brachytherapy (HDR-EB) for primary lung cancers. Radiation dose contribution from HDR-EB treatment alone, or combined HDR-EB and external beam (EBRT) were analyzed in relation to the linear representation of the tracheobronchial anatomy. Results were presented in a dose volume histogram (DVH) analysis for the risk estimate of late complications from HDR-EB. Bronchial mucosal tolerance is estimated from the clinical experience study and histopathologic changes in laboratory animals treated with HDR-EB. Methods: 1.) There were forty one patients with primary lung cancer received HDR-EB as part of the radiation treatment between December 1990 and June 1994. Six of these developed late complications manifested as either fatal hemoptysis or endobronchial deposition of fibrinous material/bronchial stenosis. Treatment planning films were reviewed to map the volume treated with HDR-EB and EBRT along the tracheobronchial segments. DVH was constructed and compared for patients with and without late complications. Other clinical parameters of interest which were analyzed included: dose per fraction, EBRT total dose, HDR total dose, combined EBRT and HDR total dose, number of catheters per treatment, and points of prescriptions for HDR-EB. 2.) Forty four New Zealand White rabbits underwent HDR-EB of the major airway to a treatment length of 2 cm (1 cm above and below the carina) to a single fraction dose of 10 Gy, 30 Gy, or 50 Gy. Histopathologic changes were examined at 7, 14, 28, and 56 days post-treatment and compared with the control rabbits which received no irradiation. Results: 1.) The late complication rate is 14.5% with three patients developing fibrinous deposits/bronchial stenosis and four patients who experienced fatal hemoptysis in a total of six patients. There is a significant difference in DVH of HDR-EB treatment in the tracheobronchial high dose region

  20. Normal tissue tolerance to external beam radiation therapy: The stomach

    International Nuclear Information System (INIS)

    Oberdiac, P.; Mineur, L.

    2010-01-01

    In the following article, we will discuss general issues relating to acute and late gastric's radiation toxicities. The tolerance of the stomach to complete or partial organ irradiation is more un-appreciated than for most other organs. We consulted the Medline database via PubMed and used the key words gastric - radiotherapy - toxicity. Currently, 60 Gy or less is prescribed in gastric radiation therapy. Acute clinical toxicity symptoms are predominantly nausea and vomiting. Although there is a general agreement that the whole stomach tolerance is for doses of 40 to 45 Gy without unacceptable complication, it is well established that a stomach dose of 35 Gy increases the risk of ulcer complications. (authors)

  1. A Phase I study of bizelesin (NSC 615291) in patients with advanced solid tumors.

    Science.gov (United States)

    Pitot, Henry C; Reid, Joel M; Sloan, Jeff A; Ames, Matthew M; Adjei, Alex A; Rubin, Joseph; Bagniewski, Pamela G; Atherton, Pamela; Rayson, Daniel; Goldberg, Richard M; Erlichman, Charles

    2002-03-01

    To evaluate the toxicities, characterize the pharmacokinetics, and determine the maximum-tolerated dose of bizelesin administered once every 4 weeks. Patients with advanced solid tumors received escalating doses of bizelesin as an i.v. push every 4 weeks. Pharmacokinetic studies were performed with the first treatment cycle. Nineteen eligible patients received a total of 54 courses of bizelesin at doses ranging from 0.1 to 1 microg/m(2). Dose-limiting toxicity of neutropenia was seen in 2 of 4 patients treated at the 1 microg/m(2) dose level. Nonhematological toxicity was generally mild with maximum toxicity being dose. The area under the concentration time curve increased in proportion to administered dose, and the clearance remained constant over the dose range studied. Correlation analysis demonstrated relationships between dose and area under the concentration with cycle 1 hematological parameters, including absolute neutrophil and leukocyte nadirs. Bizelesin administered every 4 weeks as an i.v. push is well tolerated with dose-limiting toxicity of neutropenia. The maximum-tolerated dose (and recommended Phase II dose) is 0.8 microg/m(2) administered once every 4 weeks.

  2. SU-E-T-202: Impact of Monte Carlo Dose Calculation Algorithm On Prostate SBRT Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Venencia, C; Garrigo, E; Cardenas, J; Castro Pena, P [Instituto de Radioterapia - Fundacion Marie Curie, Cordoba (Argentina)

    2014-06-01

    Purpose: The purpose of this work was to quantify the dosimetric impact of using Monte Carlo algorithm on pre calculated SBRT prostate treatment with pencil beam dose calculation algorithm. Methods: A 6MV photon beam produced by a Novalis TX (BrainLAB-Varian) linear accelerator equipped with HDMLC was used. Treatment plans were done using 9 fields with Iplanv4.5 (BrainLAB) and dynamic IMRT modality. Institutional SBRT protocol uses a total dose to the prostate of 40Gy in 5 fractions, every other day. Dose calculation is done by pencil beam (2mm dose resolution), heterogeneity correction and dose volume constraint (UCLA) for PTV D95%=40Gy and D98%>39.2Gy, Rectum V20Gy<50%, V32Gy<20%, V36Gy<10% and V40Gy<5%, Bladder V20Gy<40% and V40Gy<10%, femoral heads V16Gy<5%, penile bulb V25Gy<3cc, urethra and overlap region between PTV and PRV Rectum Dmax<42Gy. 10 SBRT treatments plans were selected and recalculated using Monte Carlo with 2mm spatial resolution and mean variance of 2%. DVH comparisons between plans were done. Results: The average difference between PTV doses constraints were within 2%. However 3 plans have differences higher than 3% which does not meet the D98% criteria (>39.2Gy) and should have been renormalized. Dose volume constraint differences for rectum, bladder, femoral heads and penile bulb were les than 2% and within tolerances. Urethra region and overlapping between PTV and PRV Rectum shows increment of dose in all plans. The average difference for urethra region was 2.1% with a maximum of 7.8% and for the overlapping region 2.5% with a maximum of 8.7%. Conclusion: Monte Carlo dose calculation on dynamic IMRT treatments could affects on plan normalization. Dose increment in critical region of urethra and PTV overlapping region with PTV could have clinical consequences which need to be studied. The use of Monte Carlo dose calculation algorithm is limited because inverse planning dose optimization use only pencil beam.

  3. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Hermann, E-mail: hermann.fuchs@meduniwien.ac.at [Department of Radiation Oncology, Division of Medical Radiation Physics, Medical University of Vienna/AKH Vienna, Vienna 1090, Austria and Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna 1090 (Austria); Alber, Markus [Department for Oncology, Aarhus University Hospital, Aarhus 8000 (Denmark); Schreiner, Thomas [PEG MedAustron, Wiener Neustadt 2700 (Austria); Georg, Dietmar [Department of Radiation Oncology, Division of Medical Radiation Physics, Medical University of Vienna/AKH Vienna, Vienna 1090 (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna 1090 (Austria); Comprehensive Cancer Center, Medical University of Vienna/AKH Vienna, Vienna 1090 (Austria)

    2015-09-15

    Purpose: Helium ions ({sup 4}He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed and integrated into the treatment planning system Hyperion. Methods: Current knowledge on RBE of {sup 4}He together with linear energy transfer considerations motivated an empirical depth-dependent “zonal” RBE model. In the plateau region, a RBE of 1.0 was assumed, followed by an increasing RBE up to 2.8 at the Bragg-peak region, which was then kept constant over the fragmentation tail. To account for a variable proton RBE, the same model concept was also applied to protons with a maximum RBE of 1.6. Both RBE models were added to a previously developed pencil beam algorithm for physical dose calculation and included into the treatment planning system Hyperion. The implementation was validated against Monte Carlo simulations within a water phantom using γ-index evaluation. The potential benefits of {sup 4}He based treatment plans were explored in a preliminary treatment planning comparison (against protons) for four treatment sites, i.e., a prostate, a base-of-skull, a pediatric, and a head-and-neck tumor case. Separate treatment plans taking into account physical dose calculation only or using biological modeling were created for protons and {sup 4}He. Results: Comparison of Monte Carlo and Hyperion calculated doses resulted in a γ{sub mean} of 0.3, with 3.4% of the values above 1 and γ{sub 1%} of 1.5 and better. Treatment plan evaluation showed comparable planning target volume coverage for both particles, with slightly increased coverage for {sup 4}He. Organ at risk (OAR) doses were generally reduced using {sup 4}He, some by more than to 30%. Improvements of {sup 4}He over protons were more pronounced for treatment plans taking biological effects into account. All

  4. Sensitization or tolerance to Mycobacterium leprae antigen by route of injection

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, C.C.; Walker, L.L.; Van Landingham, R.M.; Ye, S.Z.

    1982-11-01

    Aqueous suspensions of heat-killed Mycobacterium leprae in a dose of 10(7) organisms were highly immunogenic when injected intradermally (i.d.). The same dose of bacteria did not sensitize when given intraperitoneally (i.p.) or intravenously (i.v.), and did so only minimally at best when given subcutaneously. The i.d. route was the most immunogenic for sheep erythrocytes also. M. leprae injected i.p. or i.v. stimulated immune tolerance to M. leprae challenge i.d. In older mice (greater than or equal to 8 weeks), the i.v. injections gave more complete tolerance. Mice that had been rendered tolerant by i.v. injections maintained their tolerance for at least 168 days. Prior UV irradiation of intact mice prevented sensitization by the i.d. route. In normal mice, living M. bovis BCG given i.d. produced good sensitization to M. leprae. Mice that had been made tolerant by i.v. injection of M. leprae could be partially sensitized to M. leprae by i.d. immunization with BCG; mixtures of living BCG and heat-killed M. leprae were no more effective than BCG alone. These findings appear to have relevance to the pathogenesis of lepromatous leprosy and its immunoprophylaxis.

  5. Sensitization or tolerance to Mycobacterium leprae antigen by route of injection

    International Nuclear Information System (INIS)

    Shepard, C.C.; Walker, L.L.; Van Landingham, R.M.; Ye, S.Z.

    1982-01-01

    Aqueous suspensions of heat-killed Mycobacterium leprae in a dose of 10(7) organisms were highly immunogenic when injected intradermally (i.d.). The same dose of bacteria did not sensitize when given intraperitoneally (i.p.) or intravenously (i.v.), and did so only minimally at best when given subcutaneously. The i.d. route was the most immunogenic for sheep erythrocytes also. M. leprae injected i.p. or i.v. stimulated immune tolerance to M. leprae challenge i.d. In older mice (greater than or equal to 8 weeks), the i.v. injections gave more complete tolerance. Mice that had been rendered tolerant by i.v. injections maintained their tolerance for at least 168 days. Prior UV irradiation of intact mice prevented sensitization by the i.d. route. In normal mice, living M. bovis BCG given i.d. produced good sensitization to M. leprae. Mice that had been made tolerant by i.v. injection of M. leprae could be partially sensitized to M. leprae by i.d. immunization with BCG; mixtures of living BCG and heat-killed M. leprae were no more effective than BCG alone. These findings appear to have relevance to the pathogenesis of lepromatous leprosy and its immunoprophylaxis

  6. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1996-01-01

    The guide presents the principles to be applied in calculating the equivalent dose and the effective dose, instructions on application of the maximum values for radiation exposure, and instruction on monitoring of radiation exposure. In addition, the measurable quantities to be used in monitoring the radiation exposure are presented. (2 refs.)

  7. Application of a Monte Carlo linac model in routine verifications of dose calculations

    International Nuclear Information System (INIS)

    Linares Rosales, H. M.; Alfonso Laguardia, R.; Lara Mas, E.; Popescu, T.

    2015-01-01

    The analysis of some parameters of interest in Radiotherapy Medical Physics based on an experimentally validated Monte Carlo model of an Elekta Precise lineal accelerator, was performed for 6 and 15 Mv photon beams. The simulations were performed using the EGSnrc code. As reference for simulations, the optimal beam parameters values (energy and FWHM) previously obtained were used. Deposited dose calculations in water phantoms were done, on typical complex geometries commonly are used in acceptance and quality control tests, such as irregular and asymmetric fields. Parameters such as MLC scatter, maximum opening or closing position, and the separation between them were analyzed from calculations in water. Similarly simulations were performed on phantoms obtained from CT studies of real patients, making comparisons of the dose distribution calculated with EGSnrc and the dose distribution obtained from the computerized treatment planning systems (TPS) used in routine clinical plans. All the results showed a great agreement with measurements, finding all of them within tolerance limits. These results allowed the possibility of using the developed model as a robust verification tool for validating calculations in very complex situation, where the accuracy of the available TPS could be questionable. (Author)

  8. Phase I dose-finding study of sorafenib with FOLFOX4 as first-line treatment in patients with unresectable locally advanced or metastatic gastric cancer.

    Science.gov (United States)

    Chi, Yihebali; Yang, Jianliang; Yang, Sheng; Sun, Yongkun; Jia, Bo; Shi, Yuankai

    2015-06-01

    To determine the maximum tolerated dose (MTD), dose-limiting toxicity (DLT) and efficacy of sorafenib in combination with FOLFOX4 (oxaliplatin/leucovorin (LV)/5-fluorouracil) as first-line treatment for advanced gastric cancer, we performed a phase I dose-finding study in nine evaluable patients with unresectable locally advanced or metastatic gastric cancer or gastroesophageal junction adenocarcinoma. According to modified Fibonacci method, the design of this study was to guide elevation of the sorafenib dosage to the next level (from 200 mg twice daily to 400 mg twice daily and then, if tolerated, 600 mg twice daily). If the patient achieved complete response (CR), partial response (PR) or stable disease (SD) after eight cycles of treatment, combination chemotherapy was scheduled to be discontinued and sorafenib monotherapy continued at the original dose until either disease progression or unacceptable toxicity. In sorafenib 200 mg twice daily group, DLT was observed in 1 of 6 patients, and in 400 mg twice daily group, it was observed in 2 of 3 patients. Seven of 9 (77.8%) evaluable patients achieved PR, with a median overall survival (OS) of 11.8 [95% confidence interval (CI): 8.9-14.7] months. Common adverse effects include hand-foot syndrome, leukopenia, neutropenia, anorexia, and nausea. Twice-daily dosing of sorafenib 200 mg in combination with FOLFOX4 was proven effective and safe for the treatment of advanced gastric cancer, and could be an appropriate dosage for subsequent phase II clinical studies.

  9. Dose Constraints to Prevent Radiation-Induced Brachial Plexopathy in Patients Treated for Lung Cancer

    International Nuclear Information System (INIS)

    Amini, Arya; Yang Jinzhong; Williamson, Ryan; McBurney, Michelle L.; Erasmus, Jeremy; Allen, Pamela K.; Karhade, Mandar; Komaki, Ritsuko; Liao, Zhongxing; Gomez, Daniel; Cox, James; Dong, Lei; Welsh, James

    2012-01-01

    Purpose: As the recommended radiation dose for non-small-cell lung cancer (NSCLC) increases, meeting dose constraints for critical structures like the brachial plexus becomes increasingly challenging, particularly for tumors in the superior sulcus. In this retrospective analysis, we compared dose-volume histogram information with the incidence of plexopathy to establish the maximum dose tolerated by the brachial plexus. Methods and Materials: We identified 90 patients with NSCLC treated with definitive chemoradiation from March 2007 through September 2010, who had received >55 Gy to the brachial plexus. We used a multiatlas segmentation method combined with deformable image registration to delineate the brachial plexus on the original planning CT scans and scored plexopathy according to Common Terminology Criteria for Adverse Events version 4.03. Results: Median radiation dose to the brachial plexus was 70 Gy (range, 56–87.5 Gy; 1.5–2.5 Gy/fraction). At a median follow-up time of 14.0 months, 14 patients (16%) had brachial plexopathy (8 patients [9%] had Grade 1, and 6 patients [7%] had Grade ≥2); median time to symptom onset was 6.5 months (range, 1.4–37.4 months). On multivariate analysis, receipt of a median brachial plexus dose of >69 Gy (odds ratio [OR] 10.091; 95% confidence interval [CI], 1.512–67.331; p = 0.005), a maximum dose of >75 Gy to 2 cm 3 of the brachial plexus (OR, 4.909; 95% CI, 0.966–24.952; p = 0.038), and the presence of plexopathy before irradiation (OR, 4.722; 95% CI, 1.267–17.606; p = 0.021) were independent predictors of brachial plexopathy. Conclusions: For lung cancers near the apical region, brachial plexopathy is a major concern for high-dose radiation therapy. We developed a computer-assisted image segmentation method that allows us to rapidly and consistently contour the brachial plexus and establish the dose limits to minimize the risk of brachial plexopathy. Our results could be used as a guideline in future

  10. Tolerance of edible flowers to gamma irradiation

    International Nuclear Information System (INIS)

    Koike, Amanda C.R.; Araujo, Michel M.; Costa, Helbert S.F.; Almeida, Mariana C.; Villavicencio, Anna Lucia C.H.

    2011-01-01

    People have been eating flowers and using them in culinary creations for hundreds of years. Edible flowers are increasingly being used in meals as an ingredient in salads or garnish, entrees, drinks and desserts. The irradiation process is an alternative method that can be used in disinfestation of food and flowers, using doses that do not damage the product. The sensitivity of flowers to irradiation varies from species to species. In the present research was irradiated with doses up to 1 kGy some edible flowers to examine their physical tolerance to gamma-rays. Furthermore, high doses gamma irradiation causes petal withering, browning process and injury in edible flowers. (author)

  11. Tolerance of edible flowers to gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Amanda C.R.; Araujo, Michel M.; Costa, Helbert S.F.; Almeida, Mariana C.; Villavicencio, Anna Lucia C.H., E-mail: ackoike@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil)

    2011-07-01

    People have been eating flowers and using them in culinary creations for hundreds of years. Edible flowers are increasingly being used in meals as an ingredient in salads or garnish, entrees, drinks and desserts. The irradiation process is an alternative method that can be used in disinfestation of food and flowers, using doses that do not damage the product. The sensitivity of flowers to irradiation varies from species to species. In the present research was irradiated with doses up to 1 kGy some edible flowers to examine their physical tolerance to gamma-rays. Furthermore, high doses gamma irradiation causes petal withering, browning process and injury in edible flowers. (author)

  12. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54-56 Gy given in 9-7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size.

    Science.gov (United States)

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-04-22

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003-2008, 41 patients with 42 lung tumors were treated with SBRT to 54-56 Gy in 9-7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16-48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10-55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures.

  13. Ethanol Reversal of Tolerance to the Respiratory Depressant Effects of Morphine

    Science.gov (United States)

    Hill, Rob; Lyndon, Abi; Withey, Sarah; Roberts, Joanne; Kershaw, Yvonne; MacLachlan, John; Lingford-Hughes, Anne; Kelly, Eamonn; Bailey, Chris; Hickman, Matthew; Henderson, Graeme

    2016-01-01

    Opioids are the most common drugs associated with unintentional drug overdose. Death results from respiratory depression. Prolonged use of opioids results in the development of tolerance but the degree of tolerance is thought to vary between different effects of the drugs. Many opioid addicts regularly consume alcohol (ethanol), and post-mortem analyses of opioid overdose deaths have revealed an inverse correlation between blood morphine and ethanol levels. In the present study, we determined whether ethanol reduced tolerance to the respiratory depressant effects of opioids. Mice were treated with opioids (morphine, methadone, or buprenorphine) for up to 6 days. Respiration was measured in freely moving animals breathing 5% CO2 in air in plethysmograph chambers. Antinociception (analgesia) was measured as the latency to remove the tail from a thermal stimulus. Opioid tolerance was assessed by measuring the response to a challenge dose of morphine (10 mg/kg i.p.). Tolerance developed to the respiratory depressant effect of morphine but at a slower rate than tolerance to its antinociceptive effect. A low dose of ethanol (0.3 mg/kg) alone did not depress respiration but in prolonged morphine-treated animals respiratory depression was observed when ethanol was co-administered with the morphine challenge. Ethanol did not alter the brain levels of morphine. In contrast, in methadone- or buprenorphine-treated animals no respiratory depression was observed when ethanol was co-administered along with the morphine challenge. As heroin is converted to morphine in man, selective reversal of morphine tolerance by ethanol may be a contributory factor in heroin overdose deaths. PMID:26171718

  14. PRODUTIVIDADE DE CAPIM-MOMBAÇA (Panicum maximum, COM DIFERENTES DOSES DE BIOFERTILIZANTE / MOMBAÇA GRASS PRODUCTIVITY (Panicum maximum, WITH DIFFERENT DOSES OF BIOFERTILIZER

    Directory of Open Access Journals (Sweden)

    A. Simonetti

    2016-03-01

    Full Text Available O presente estudo teve por objetivo verificar a influência da aplicação do dejeto de bovino leiteiro tratados em biodigestores anaeróbios, na forma de biofertilizante, sobre a produtividade da capim Mombaça, em condições de sequeiro.  O trabalho foi conduzido no Instituto de Biotecnologia – IBIOTEC, pertencente à UNIARA, Araraquara – SP. Para obtenção do biofertilizante, foi feita a diluição dos dejetos em água e armazenado em um biodigestor modelo indiano de fibra de vidro com capacidade útil de 1000 L, instalado no referido instituto. As fertilizações foram feitas a lanço após cada rebaixamento das parcelas. O delineamento utilizado foi em blocos casualizados, com quatro tratamentos e quatro repetições, com diferentes doses do biofertilizante, sendo: 0; 50m³; 100m³ e 200m³/ha-1.  As variáveis avaliadas foram: altura, produção por hectare (matéria seca e matéria verde, e qualidade bromatológica. Foram observados que os tratamentos que receberam a maior dosagem de biofertilizante, apresentaram maiores valores para produtividade Matéria Seca, Matéria Verde e teor de proteína. Conclui-se que a aplicação de biofertilizante é benéfico ao sistema de pastagem, porém suas doses devem ser estudadas e a sua resposta na produção pode obtidas a longo prazo.

  15. Pharmacokinetics and tolerability of a higher rifampin dose versus the standard dose in pulmonary tuberculosis patients.

    NARCIS (Netherlands)

    Ruslami, R.; Nijland, H.M.J.; Alisjahbana, B.; Parwati, I.; Crevel, R. van; Aarnoutse, R.E.

    2007-01-01

    Rifampin is a key drug for tuberculosis (TB) treatment. The available data suggest that the currently applied 10-mg/kg of body weight dose of rifampin may be too low and that increasing the dose may shorten the treatment duration. A double-blind randomized phase II clinical trial was performed to

  16. Anilofos tolerance and its mineralization by the cyanobacterium Synechocystis sp. strain PUPCCC 64.

    Directory of Open Access Journals (Sweden)

    D P Singh

    Full Text Available This study deals with anilofos tolerance and its mineralization by the common rice field cyanobacterium Synechocystis sp. strain PUPCCC 64. The organism tolerated anilofos up to 25 mg L(-1. The herbicide caused inhibitory effects on photosynthetic pigments of the test organism in a dose-dependent manner. The organism exhibited 60, 89, 96, 85 and 79% decrease in chlorophyll a, carotenoids, phycocyanin, allophycocyanin and phycoerythrin, respectively, in 20 mg L(-1 anilofos on day six. Activities of superoxide dismutase, catalase and peroxidase increased by 1.04 to 1.80 times over control cultures in presence of 20 mg L(-1 anilofos. Glutathione content decreased by 26% while proline content was unaffected by 20 mg L(-1 anilofos. The test organism showed intracellular uptake and metabolized the herbicide. Uptake of herbicide by test organism was fast during initial six hours followed by slow uptake until 120 hours. The organism exhibited maximum anilofos removal at 100 mg protein L(-1, pH 8.0 and 30°C. Its growth in phosphate deficient basal medium in the presence of anilofos (2.5 mg L(-1 indicated that herbicide was used by the strain PUPCCC 64 as a source of phosphate.

  17. Influence of the Target Vessel on the Location and Area of Maximum Skin Dose during Percutaneous Coronary Intervention

    International Nuclear Information System (INIS)

    Chida, K.; Fuda, K.; Kagaya, Y.; Saito, H.; Takai, Y.; Kohzuki, M.; Takahash i, S.; Yamada, S.; Zuguchi, M.

    2007-01-01

    Background: A number of cases involving radiation-associated patient skin injury attributable to percutaneous coronary intervention (PCI) have been reported. Knowledge of the location and area of the patient's maximum skin dose (MSD) in PCI is necessary to reduce the risk of skin injury. Purpose: To determine the location and area of the MSD in PCI, and separately analyze the effects of different target vessels. Material and Methods: 197 consecutive PCI procedures were studied, and the location and area of the MSD were calculated by a skin-dose mapping software program: Caregraph. The target vessels of the PCI procedures were divided into four groups based on the American Heart Association (AHA) classification. Results: The sites of the MSD for AHA no.1-3, AHA no.4, and AHA no.11-15 were located mainly on the right back skin, the lower right or center back skin, and the upper back skin areas, respectively, whereas the MSD sites for the AHA no. 5-10 PCI were widely spread. The MSD area for the AHA no. 4 PCI was larger than that for the AHA no. 11-15 PCI (P<0.0001). Conclusion: Although the radiation associated with PCI can be widely spread and variable, we observed a tendency regarding the location and area of the MSD when we separately analyzed the data for different target vessels. We recommend the use of a smaller radiation field size and the elimination of overlapping fields during PCI

  18. 78 FR 32146 - Triforine; Pesticide Tolerances

    Science.gov (United States)

    2013-05-29

    ... America Holding Corporation requested these tolerances under the Federal Food, Drug, and Cosmetic Act... in the liver and hematopoietic system following repeated oral dosing, and the dog is the most... UFA = 10x mg/kg/day. (dog) UFH = 10x cPAD = 0.22 mg/kg/ LOAEL = 120 mg/kg/day, based on FQPA SF = 1x...

  19. Dose distributions of pendulum fields in the field border plane

    International Nuclear Information System (INIS)

    Schrader, R.

    1986-01-01

    Calculations (program SIDOS-U2) and LiF measurements taken in a cylindric water phantom are used to investigate the isodose distributions of different pendulum irradiation methods (Co-60) in a plane which is parallel to the central ray plane and crosses the field borders at the depth of the axis. The dose values compared to the maximum values of the central ray plane are completely different for each pendulum method. In case of monoaxial pendulum methods around small angles, the maximum dose value found in the border plane is less than 50% of the dose in the central ray plane. The relative maximum of the border plane moves to tissues laying in a greater depth. In case of bi-axial methods, the maximum value of the border plane can be much more than 50% of the maximum dose measured in the central ray plane. (orig.) [de

  20. The time course of ethanol tolerance: associative learning

    Directory of Open Access Journals (Sweden)

    J.L.O. Bueno

    2007-11-01

    Full Text Available The effect of different contextual stimuli on different ethanol-induced internal states was investigated during the time course of both the hypothermic effect of the drug and of drug tolerance. Minimitters were surgically implanted in 16 Wistar rats to assess changes in their body temperature under the effect of ethanol. Rat groups were submitted to ethanol or saline trials every other day. The animals were divided into two groups, one receiving a constant dose (CD of ethanol injected intraperitoneally, and the other receiving increasing doses (ID during the 10 training sessions. During the ethanol training sessions, conditioned stimuli A (tone and B (buzzer were presented at "state +" (35 min after drug injection and "state -" (170 min after drug injection, respectively. Conditioned stimuli C (bip and D (white noise were presented at moments equivalent to stimuli A and B, respectively, but during the saline training sessions. All stimuli lasted 15 min. The CD group, but not the ID group, developed tolerance to the hypothermic effect of ethanol. Stimulus A (associated with drug "state +" induced hyperthermia with saline injection in the ID group. Stimulus B (associated with drug "state -" reduced ethanol tolerance in the CD group and modulated the hypothermic effect of the drug in the ID group. These results indicate that contextual stimuli acquire modulatory conditioned properties that are associated with the time course of both the action of the drug and the development of drug tolerance.

  1. Chronic ethanol or nicotine treatment results in partial cross-tolerance between these agents.

    Science.gov (United States)

    Burch, J B; de Fiebre, C M; Marks, M J; Collins, A C

    1988-01-01

    Female DBA/2Ibg mice were treated chronically (21 days) with ethanol- or dextrin-containing liquid diets or infused chronically with nicotine (8 mg/kg/h) or saline for 10 days. The responses of these animals to challenge doses of ethanol (2.5 g/kg) or nicotine (1 or 2 mg/kg) were measured using a test battery consisting of respiration rate, acoustic startle response, Y-maze crosses and rears, heart rate and body temperature. Chronic ethanol-treated animals were tolerant to the effects elicited by a challenge dose of ethanol on four of the six measures and were cross-tolerant to nicotine's effects on the acoustic startle test. Chronic nicotine-treated animals were tolerant to nicotine's effects on five of the six measures and cross-tolerant to ethanol's effects on heart rate and body temperature. Thus, partial cross-tolerance between ethanol and nicotine exists. Chronic nicotine treatment resulted in significant increases in L-[3H]-nicotine binding in six of seven brain regions and in alpha-[125I]-bungarotoxin binding in three of seven brain regions. Chronic ethanol treatment failed to alter the binding of either ligand. Therefore, the cross-tolerance that develops between ethanol and nicotine is not totally dependent on alterations in the number of brain nicotinic receptors.

  2. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  3. Temperature-stress resistance and tolerance along a latitudinal cline in North American Arabidopsis lyrata.

    Directory of Open Access Journals (Sweden)

    Guillaume Wos

    Full Text Available The study of latitudinal gradients can yield important insights into adaptation to temperature stress. Two strategies are available: resistance by limiting damage, or tolerance by reducing the fitness consequences of damage. Here we studied latitudinal variation in resistance and tolerance to frost and heat and tested the prediction of a trade-off between the two strategies and their costliness. We raised plants of replicate maternal seed families from eight populations of North American Arabidopsis lyrata collected along a latitudinal gradient in climate chambers and exposed them repeatedly to either frost or heat stress, while a set of control plants grew under standard conditions. When control plants reached maximum rosette size, leaf samples were exposed to frost and heat stress, and electrolyte leakage (PEL was measured and treated as an estimate of resistance. Difference in maximum rosette size between stressed and control plants was used as an estimate of tolerance. Northern populations were more frost resistant, and less heat resistant and less heat tolerant, but-unexpectedly-they were also less frost tolerant. Negative genetic correlations between resistance and tolerance to the same and different thermal stress were generally not significant, indicating only weak trade-offs. However, tolerance to frost was consistently accompanied by small size under control conditions, which may explain the non-adaptive latitudinal pattern for frost tolerance. Our results suggest that adaptation to frost and heat is not constrained by trade-offs between them. But the cost of frost tolerance in terms of plant size reduction may be important for the limits of species distributions and climate niches.

  4. Tolerability, safety and efficacy of Iloprost infusion without peristaltic pump in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    S. Tosi

    2011-09-01

    Full Text Available Objective. To evaluate safety, tolerability and efficacy on Raynaud’s phenomenon (Rp of iloprost infusion without peristaltic pump in patients with systemic sclerosis (SSc. Patients and methods. The inclusion criteria were diagnosis of SSc, age between 18 and 65 years, presence of Rp, and absence of any controindication to the use of iloprost. The treatment was carried out in a day hospital setting and consisted first of 5 consecutive days of iloprost infusion (from an initial dose of 1.0 ng/Kg/min up to 2 ng/kg/min, and then of 2 days of infusions at the maximum possible dose every 45 days for one year. All of the adverse events were carefully recorded and the changes in the Rp were measured by a 5 grade scale (worsened, unmodified, slightly improved, very improved, disappeared. Results. Thirty-eight SSc patients (all females, mean age 49 years (range 18.5-65, disease duration 1.5 years (range 0.5-10.8 were enrolled in the study. During the first cycle of therapy, 14 avderse events occurred in 11 (28.9% patients and during the next cycles, 3 adverse events were seen in 3 (7.9% patients. In all of the cases they were mild and transient. Rp was considered very improved in 15 (39.5% patients, slightly improved in 13 (34.2%, unmodified in 8 (21% and worse in 2 (5.2%. Discussion. In this study intravenous iloprost without peristaltic pump proved to be safe, well tolerated, and as effective as traditional infusion through peristaltic pump in improving Rp in patients with SSc.

  5. A Phase I/II Trial of Intensity Modulated Radiation (IMRT) Dose Escalation With Concurrent Fixed-dose Rate Gemcitabine (FDR-G) in Patients With Unresectable Pancreatic Cancer

    International Nuclear Information System (INIS)

    Ben-Josef, Edgar; Schipper, Mathew; Francis, Isaac R.; Hadley, Scott; Ten-Haken, Randall; Lawrence, Theodore; Normolle, Daniel; Simeone, Diane M.; Sonnenday, Christopher; Abrams, Ross; Leslie, William; Khan, Gazala; Zalupski, Mark M.

    2012-01-01

    Purpose: Local failure in unresectable pancreatic cancer may contribute to death. We hypothesized that intensification of local therapy would improve local control and survival. The objectives were to determine the maximum tolerated radiation dose delivered by intensity modulated radiation with fixed-dose rate gemcitabine (FDR-G), freedom from local progression (FFLP), and overall survival (OS). Methods and Materials: Eligibility included pathologic confirmation of adenocarcinoma, radiographically unresectable, performance status of 0-2, absolute neutrophil count of ≥1500/mm 3 , platelets ≥100,000/mm 3 , creatinine 2 /100 min intravenously) was given on days −22 and −15, 1, 8, 22, and 29. Intensity modulated radiation started on day 1. Dose levels were escalated from 50-60 Gy in 25 fractions. Dose-limiting toxicity was defined as gastrointestinal toxicity grade (G) ≥3, neutropenic fever, or deterioration in performance status to ≥3 between day 1 and 126. Dose level was assigned using TITE-CRM (Time-to-Event Continual Reassessment Method) with the target dose-limiting toxicity (DLT) rate set to 0.25. Results: Fifty patients were accrued. DLTs were observed in 11 patients: G3/4 anorexia, nausea, vomiting, and/or dehydration (7); duodenal bleed (3); duodenal perforation (1). The recommended dose is 55 Gy, producing a probability of DLT of 0.24. The 2-year FFLP is 59% (95% confidence interval [CI]: 32-79). Median and 2-year overall survival are 14.8 months (95% CI: 12.6-22.2) and 30% (95% CI 17-45). Twelve patients underwent resection (10 R0, 2 R1) and survived a median of 32 months. Conclusions: High-dose radiation therapy with concurrent FDR-G can be delivered safely. The encouraging efficacy data suggest that outcome may be improved in unresectable patients through intensification of local therapy.

  6. Occupational dose assessment in interventional cardiology in Serbia

    International Nuclear Information System (INIS)

    Kaljevic, J.; Ciraj-Bjelac, O.; Stankovic, J.; Arandjic, D.; Bozovic, P.; Antic, V.

    2016-01-01

    The objective of this work is to assess the occupational dose in interventional cardiology in a large hospital in Belgrade, Serbia. A double-dosimetry method was applied for the estimation of whole-body dose, using thermoluminescent dosemeters, calibrated in terms of the personal dose equivalent H p (10). Besides the double-dosimetry method, eye dose was also estimated by means of measuring ambient dose equivalent, H*(10), and doses per procedure were reported. Doses were assessed for 13 physicians, 6 nurses and 10 radiographers, for 2 consequent years. The maximum annual effective dose assessed was 4.3, 2.1 and 1.3 mSv for physicians, nurses and radiographers, respectively. The maximum doses recorded by the dosemeter worn at the collar level (over the apron) were 16.8, 11.9 and 4.5 mSv, respectively. This value was used for the eye lens dose assessment. Estimated doses are in accordance with or higher than annual dose limits for the occupational exposure. (authors)

  7. A study on the variation of bladder and rectal doses with respiration in intracavitary brachytherapy for cervix cancer

    Directory of Open Access Journals (Sweden)

    Singh Karuna

    2010-04-01

    Full Text Available Purpose: In cervical intracavitary brachytherapy, it is mandatory to evaluate if the doses to bladder and rectum are within tolerance limits. In this study, an effort has been made to evaluate the effect of respiration on the doses to bladder and rectum in patients undergoing brachytherapy.Material and methods: Fifteen patients with cervix cancer treated with concurrent chemoradiation followed by intracavitary brachytherapy were included in this study. At the time of brachytherapy, all patients underwent 4D computed tomography (CT imaging. Five out of fifteen patients were scanned with empty bladder while the rest had full bladder during sectional imaging. Four sets of pelvic CT image datasets with applicators in place were acquired at equal interval in a complete respiratory cycle. Treatment plans were generated for all the CT datasets on a PlatoTM Sunrise planning system. A dose of 7 Gy was prescribed to Point A. Doses to ICRU (Report No.38 bladder (IBRP and rectal (IRRP reference points were calculated in all the CT datasets.Results: The mean of maximum dose to IBRP at four different respiratory phases for full and empty bladder were 53.38 ± 19.20%, 55.75 ± 16.71%, 56.13 ± 17.70%, 57.50 ± 17.48% and 60.93 ± 15.18%, 60.29 ± 16.28%, 60.86 ± 15.90%, 60.82 ± 15.42% of the prescribed dose respectively. Similarly, maximum dose to IRRP for full and empty bladder were 55.50 ± 18.66%, 57.38 ± 14.81%, 58.00 ± 14.97%, 58.38 ± 17.28% and 71.96 ± 6.90%, 71.58 ± 7.52%, 68.92 ± 6.21%, 71.45 ± 7.16% respectively.Conclusions: Our study shows that respiration affects the dose distribution to the bladder and rectum in intracavitary brachytherapy of cervix cancer. It is advisable to reduce the critical organ dose to account for the dose variation introduced by respiratory motion.

  8. Noise tolerant dendritic lattice associative memories

    Science.gov (United States)

    Ritter, Gerhard X.; Schmalz, Mark S.; Hayden, Eric; Tucker, Marc

    2011-09-01

    Linear classifiers based on computation over the real numbers R (e.g., with operations of addition and multiplication) denoted by (R, +, x), have been represented extensively in the literature of pattern recognition. However, a different approach to pattern classification involves the use of addition, maximum, and minimum operations over the reals in the algebra (R, +, maximum, minimum) These pattern classifiers, based on lattice algebra, have been shown to exhibit superior information storage capacity, fast training and short convergence times, high pattern classification accuracy, and low computational cost. Such attributes are not always found, for example, in classical neural nets based on the linear inner product. In a special type of lattice associative memory (LAM), called a dendritic LAM or DLAM, it is possible to achieve noise-tolerant pattern classification by varying the design of noise or error acceptance bounds. This paper presents theory and algorithmic approaches for the computation of noise-tolerant lattice associative memories (LAMs) under a variety of input constraints. Of particular interest are the classification of nonergodic data in noise regimes with time-varying statistics. DLAMs, which are a specialization of LAMs derived from concepts of biological neural networks, have successfully been applied to pattern classification from hyperspectral remote sensing data, as well as spatial object recognition from digital imagery. The authors' recent research in the development of DLAMs is overviewed, with experimental results that show utility for a wide variety of pattern classification applications. Performance results are presented in terms of measured computational cost, noise tolerance, classification accuracy, and throughput for a variety of input data and noise levels.

  9. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    International Nuclear Information System (INIS)

    Rahimi, Asal; Thomas, Kimberly; Spangler, Ann; Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha; Seiler, Stephen; Albuquerque, Kevin; Stevenson, Stella; Goudreau, Sally; Garwood, Dan; Haley, Barbara; Euhus, David; Heinzerling, John; Ding, Chuxiong; Gao, Ang; Ahn, Chul; Timmerman, Robert

    2017-01-01

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for

  10. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, Asal, E-mail: asal.rahimi@utsouthwestern.edu [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Thomas, Kimberly; Spangler, Ann [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha [Department of Surgery, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Seiler, Stephen [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Albuquerque, Kevin; Stevenson, Stella [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Goudreau, Sally [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Garwood, Dan [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Haley, Barbara [Department of Medical Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Euhus, David [Department of Surgery, Johns Hopkins University, Baltimore, Maryland (United States); Heinzerling, John [Department of Radiation Oncology, Levine Cancer Institute, Charlotte, North Carolina (United States); Ding, Chuxiong [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Gao, Ang; Ahn, Chul [Department of Statistics, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Timmerman, Robert [University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2017-05-01

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for

  11. Hardness, function, emotional well-being, satisfaction and the overall sexual experience in men using 100-mg fixed-dose or flexible-dose sildenafil citrate.

    Science.gov (United States)

    Ströberg, P; Kaminetsky, J C; Park, N C; Goldfischer, E R; Creanga, D L; Stecher, V J

    2010-01-01

    The prescribing information for sildenafil citrate (VIAGRA, Pfizer, New York, NY, USA) recommends flexible dosing (50 mg initially, adjusted to 100 or 25 mg based on effectiveness and tolerability) in most men with erectile dysfunction (ED). In many men, however, 100 mg may be the most appropriate initial dose because it would reduce the need for titration and could prevent discouragement and treatment abandonment should 50 mg be insufficient. Results of two previously published double-blind, placebo-controlled sildenafil trials of similar design except for a fixed-dose vs flexible-dose regimen were analyzed. Relative to the flexible-dose, approximately one-third more men were satisfied with an initial and fixed dose of 100 mg. In addition, tolerability was similar, and improvements from baseline in outcomes on validated, ED-specific, patient-reported questionnaires were either similar (erectile function and the percentage of completely hard and fully rigid erections) or greater (emotional well-being and the overall sexual experience). The similarity in outcomes is not surprising given that almost 90% of the men in the flexible-dose trial titrated to 100 mg after 2 weeks. These data suggest prescription of an initial dose of 100 mg for men with ED, except in those for whom it is inappropriate.

  12. Relationship between sodium influx and salt tolerance of nitrogen-fixing cyanobacteria

    Energy Technology Data Exchange (ETDEWEB)

    Apte, S.K.; Reddy, B.R.; Thomas, J.

    1987-08-01

    The relationship between sodium uptake and cyanobacterial salt (NaCl) tolerance has been examined in two filamentous, heterocystous, nitrogen-fixing species of Anabaena. During diazotrophic growth at neutral pH of the growth medium, Anabaena sp. strain L-31, a freshwater strain, showed threefold higher uptake of Na+ than Anabaena torulosa, a brackish-water strain, and was considerably less salt tolerant (50% lethal dose of NaCl, 55 mM) than the latter (50% lethal dose of NaCl, 170 mM). Alkaline pH or excess K+ (more than 25 mM) in the medium causes membrane depolarization and inhibits Na+ influx in both cyanobacteria (S.K. Apte and J. Thomas, Eur. J. Biochem. 154:395-401, 1986). The presence of nitrate or ammonium in the medium caused inhibition of Na+ influx accompanied by membrane depolarization. These experimental manipulations affecting Na+ uptake demonstrated a good negative correlation between Na+ influx and salt tolerance. All treatments which inhibited Na+ influx (such as alkaline pH, K+ above 25 mM, NO3-, and NH4+), enhanced salt tolerance of not only the brackish-water but also the freshwater cyanobacterium. The results indicate that curtailment of Na+ influx, whether inherent or effected by certain environmental factors (e.g., combined nitrogen, alkaline pH), is a major mechanism of salt tolerance in cyanobacteria. (Refs. 27)

  13. Maximum entropy technique in the doublet structure analysis

    International Nuclear Information System (INIS)

    Belashev, B.Z.; Panebrattsev, Yu.A.; Shakhaliev, Eh.I.; Soroko, L.M.

    1998-01-01

    The Maximum Entropy Technique (MENT) for solution of the inverse problems is explained. The effective computer program for resolution of the nonlinear equations system encountered in the MENT has been developed and tested. The possibilities of the MENT have been demonstrated on the example of the MENT in the doublet structure analysis of noisy experimental data. The comparison of the MENT results with results of the Fourier algorithm technique without regularization is presented. The tolerant noise level is equal to 30% for MENT and only 0.1% for the Fourier algorithm

  14. Diode laser trans - scleral cyclo - ablation as a primary surgical treatment for primary open - angle glaucoma after maximum tolerated medical therapy

    International Nuclear Information System (INIS)

    Mahmood, K.; Khan, M.T.; Butt, J.B.Y.

    2011-01-01

    The incidence rate and prevalence of glaucoma in Pakistan is similar to that of other dark - colored population countries. Primary trabeculectomy is still a preferred surgical approach. Diode laser is widely accepted as the therapy of choice in severe glaucoma cases. The purpose of this study was to deter-mine the role of Diode Laser Transscleral Cyclo-ablation as a primary surgical treatment option in Primary Open Angle Glaucoma after maximum tolerated medical therapy. This quasi - experimental study was con-ducted at Layton Rahmatullah Benevolent Trust Free Eye Care and Cancer Hospital, Lahore. Sixty patients fulfilling the inclusion criteria were selected from the Glaucoma unit for this study. 25 - 30 burns of Diode Laser were applied to 270 degrees avoiding 3 and 9 O clock positions, 1.5 mm posterior to the limbus. Laser was set at duration of 1 second and power between 1000 and 1500 mw. Patients were followed up for a period of one year. Results: Out of a total of 60 eyes with mean age 52.73 +- 7.40 years, 36 (60%) were male and 24 (40%) were female. The mean pre-operative Intra Ocular Pressure IOP was 41.0 +- 7.0 mmHg (The pre-operative IOP ranged from 28 mmHg to 60 mmHg). The mean post-operative IOP was 18.97 mmHg on day one, 16.75 mmHg at 1 week, 15.68 mmHg at 1 month, 15.00 mmHg at 6 months and by the end of a year it was about 14.15 mmHg (The post-operative IOP ranged from 6 mmHg to 52 mmHg). There was a significant drop of more than 50% of post-operative IOP as compared to pre-operative IOP. Conclusion: Diode Laser Transscleral Cycloablation is a practical, rapid, well - tolerated procedure that provides a significant lowering of intraocular pressure with few complications and can considered as alternative treatment in POAG if medical therapy fails. (author)

  15. Exercise (effort) tolerance and factors affecting this tolerance for liquidators of consequences of the ChNPP accident

    International Nuclear Information System (INIS)

    Khomazyuk, I.N.

    1992-01-01

    Physical efficiency and factors affecting it for persons exposed to irradiation (the radiation dose being in the range up to 0.75 Gy) has been studied. 670 participants of liquidating the consequences of ChNPP accident have been examined. Depending on the radiation doses to which the people have been exposed the liquidators have been subdivided into 4 groups: for the 1st group the radiation doses ranging from 0.25 to 0.75 Gy; for the 2nd group the radiation doses ranging from 0.10 to 0.24 Gy; for the 3rd group the radiation doses ranging from 0.05 to 0.10 Gy; for the 4th group the radiation dose being up to 0.05 Gy. The physical load was ensured with veloergometer. The results have made it possible to estimate one of the basic health criterion for liquidators of consequences of ChNPP accident (i.e. exercise (effort) tolerance). No direct relationship of the exercise magnitude and the radiation dose within the range up to 0.75 Gy and the irradiation time have been observed. The correlation of the exercise magnitude with due account to age has been provided. 15 refs.; 2 tabs

  16. Safety, tolerability, and cerebrospinal fluid penetration of ursodeoxycholic Acid in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Parry, Gareth J; Rodrigues, Cecilia M P; Aranha, Marcia M; Hilbert, Sarah J; Davey, Cynthia; Kelkar, Praful; Low, Walter C; Steer, Clifford J

    2010-01-01

    Amyotrophic lateral sclerosis is a progressive degenerative disease, which typically leads to death in 3 to 5 years. Neuronal cell death offers a potential target for therapeutic intervention. Ursodeoxycholic acid is a cytoprotective, endogenous bile acid that has been shown to be neuroprotective in experimental Huntington and Alzheimer diseases, retinal degeneration, and ischemic and hemorrhagic stroke. The objective of this research was to study the safety and the tolerability of ursodeoxycholic acid in amyotrophic lateral sclerosis and document effective and dose-dependent cerebrospinal fluid penetration. Eighteen patients were randomly assigned to receive ursodeoxycholic acid at doses of 15, 30, and 50 mg/kg of body weight per day. Serum and cerebrospinal fluid were obtained for analysis after 4 weeks of treatment. Treatment-emergent clinical and laboratory events were monitored weekly. Our data indicated that ursodeoxycholic acid is well tolerated by all subjects at all doses. We also showed that ursodeoxycholic acid is well absorbed after oral administration and crosses the blood-brain barrier in a dose-dependent manner. These results show excellent safety and tolerability of ursodeoxycholic acid. The drug penetrates the cerebrospinal fluid in a dose-dependent manner. A large, placebo-controlled clinical trial is needed to assess the efficacy of ursodeoxycholic acid in treating amyotrophic lateral sclerosis.

  17. The H3 antagonist ABT-288 is tolerated at significantly higher exposures in subjects with schizophrenia than in healthy volunteers.

    Science.gov (United States)

    Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Gertsik, Lev; Dutta, Sandeep

    2014-06-01

    ABT-288 is a potent and selective H3 receptor antagonist with procognitive effects in several preclinical models. In previous studies, 3 mg once daily was the maximal tolerated dose in healthy volunteers. This study characterized the safety, tolerability and pharmacokinetics of ABT-288 in stable subjects with schizophrenia. This was a randomized, double-blind, placebo-controlled, dose-escalating study of ABT-288 (10 dose levels, from 1 to 60 mg once daily for 14 days) in stable subjects with schizophrenia treated with an atypical antipsychotic. In each dose group, five to seven and two to three participants were assigned to ABT-288 and placebo, respectively. Of the 67 participants enrolled, nine participants (on ABT-288) were prematurely discontinued, in seven of these due to adverse events. ABT-288 was generally safe and tolerated at doses up to 45 mg once daily. The most common adverse events, in decreasing frequency (from 31 to 5%), were abnormal dreams, headache, insomnia, dizziness, somnolence, dysgeusia, dry mouth, psychotic disorder, parosmia and tachycardia. Adverse events causing early termination were psychotic events (four) and increased creatine phosphokinase, pyrexia and insomnia (one each). The half-life of ABT-288 ranged from 28 to 51 h, and steady state was achieved by day 12 of dosing. At comparable multiple doses, ABT-288 exposure in subjects with schizophrenia was 45% lower than that previously observed in healthy subjects. At trough, ABT-288 cerebrospinal fluid concentrations were 40% of the total plasma concentrations. ABT-288 was tolerated at a 15-fold higher dose and 12-fold higher exposures in subjects with schizophrenia than previously observed in healthy volunteers. The greater ABT-288 tolerability was not due to limited brain uptake. © 2013 The British Pharmacological Society.

  18. A phase I open-label dose-escalation study of the anti-HER3 monoclonal antibody LJM716 in patients with advanced squamous cell carcinoma of the esophagus or head and neck and HER2-overexpressing breast or gastric cancer.

    Science.gov (United States)

    Reynolds, Kerry Lynn; Bedard, Philippe L; Lee, Se-Hoon; Lin, Chia-Chi; Tabernero, Josep; Alsina, Maria; Cohen, Ezra; Baselga, José; Blumenschein, George; Graham, Donna M; Garrido-Laguna, Ignacio; Juric, Dejan; Sharma, Sunil; Salgia, Ravi; Seroutou, Abdelkader; Tian, Xianbin; Fernandez, Rose; Morozov, Alex; Sheng, Qing; Ramkumar, Thiruvamoor; Zubel, Angela; Bang, Yung-Jue

    2017-09-12

    Human epidermal growth factor receptor 3 (HER3) is important in maintaining epidermal growth factor receptor-driven cancers and mediating resistance to targeted therapy. A phase I study of anti-HER3 monoclonal antibody LJM716 was conducted with the primary objective to identify the maximum tolerated dose (MTD) and/or recommended dose for expansion (RDE), and dosing schedule. Secondary objectives were to characterize safety/tolerability, pharmacokinetics, pharmacodynamics, and preliminary antitumor activity. This open-label, dose-finding study comprised dose escalation, followed by expansion in patients with squamous cell carcinoma of the head and neck or esophagus, and HER2-overexpressing metastatic breast cancer or gastric cancer. During dose escalation, patients received LJM716 intravenous once weekly (QW) or every two weeks (Q2W), in 28-day cycles. An adaptive Bayesian logistic regression model was used to guide dose escalation and establish the RDE. Exploratory pharmacodynamic tumor studies evaluated modulation of HER3 signaling. Patients received LJM716 3-40 mg/kg QW and 20 mg/kg Q2W (54 patients; 36 patients at 40 mg/kg QW). No dose-limiting toxicities (DLTs) were reported during dose-escalation. One patient experienced two DLTs (diarrhea, hypokalemia [both grade 3]) in the expansion phase. The RDE was 40 mg/kg QW, providing drug levels above the preclinical minimum effective concentration. One patient with gastric cancer had an unconfirmed partial response; 17/54 patients had stable disease, two lasting >30 weeks. Down-modulation of phospho-HER3 was observed in paired tumor samples. LJM716 was well tolerated; the MTD was not reached, and the RDE was 40 mg/kg QW. Further development of LJM716 is ongoing. Clinicaltrials.gov registry number NCT01598077 (registered on 4 May, 2012).

  19. Pharmacokinetics and tolerability of DA-8031, a novel selective serotonin reuptake inhibitor for premature ejaculation in healthy male subjects

    Directory of Open Access Journals (Sweden)

    Shin D

    2017-03-01

    Full Text Available Dongseong Shin,1 SeungHwan Lee,2 Sojeong Yi,2 Seo Hyun Yoon,2 Joo-Youn Cho,2 Mi Young Bahng,3 In-Jin Jang,2 Kyung-Sang Yu2 1Clinical Trials Center, Gachon University Gil Medical Center, Incheon, 2Department of Clinical Pharmacology and Therapeutics, Seoul National University College of Medicine and Hospital, 3Department of Product Development, Dong-A ST, Seoul, Korea Objective: DA-8031 is a selective serotonin reuptake inhibitor under development for the treatment of premature ejaculation. This is the first-in-human study aimed at evaluating the pharmacokinetics and tolerability of DA-8031 and its metabolites (M1, M2, M4, and M5 in the plasma and urine after administration of a single oral dose in healthy male subjects.Methods: A dose block-randomized, double-blind, placebo-controlled, single ascending dose study was conducted. Subjects received either placebo or a single dose of DA-8031 at 5, 10, 20, 40, 60, 80, or 120 mg. DA-8031 and its four metabolites were analyzed in the plasma and urine for pharmacokinetic evaluation. The effect of genetic polymorphisms of cytochrome-P450 (CYP enzymes on the pharmacokinetics of DA-8031 was evaluated.Results: After a single dose, plasma DA-8031 reached the maximum concentration at a median of 2–3 h and was eliminated with terminal elimination half-life of 17.9–28.7 h. The mean renal clearance was 3.7–5.6 L/h. Dose-proportional pharmacokinetics was observed over the dose range of 20–80 mg. Among the metabolites, M4 had the greatest plasma concentration, followed by M5 and M1. Subjects with CYP2D6 intermediate metabolizer had significantly greater dose-normalized Cmax and AUC0–t of DA-8031 as well as smaller metabolic ratios than those subjects with CYP2D6 extensive metabolizer. The most common adverse events were nausea, dizziness, and headache, and no serious adverse events were reported.Conclusion: In conclusion, the systemic exposure of DA-8031 was increased proportionally to the dose within 20

  20. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  1. A phase I study with neratinib (HKI-272), an irreversible pan ErbB receptor tyrosine kinase inhibitor, in patients with solid tumors.

    Science.gov (United States)

    Wong, Kwok-K; Fracasso, Paula M; Bukowski, Ronald M; Lynch, Thomas J; Munster, Pamela N; Shapiro, Geoffrey I; Jänne, Pasi A; Eder, Joseph P; Naughton, Michael J; Ellis, Matthew J; Jones, Suzanne F; Mekhail, Tarek; Zacharchuk, Charles; Vermette, Jennifer; Abbas, Richat; Quinn, Susan; Powell, Christine; Burris, Howard A

    2009-04-01

    The dose-limiting toxicities, maximum tolerated dose, pharmacokinetic profile, and preliminary antitumor activity of neratinib (HKI-272), an irreversible pan ErbB inhibitor, were determined in patients with advanced solid tumors. Neratinib was administered orally as a single dose, followed by a 1-week observation period, and then once daily continuously. Planned dose escalation was 40, 80, 120, 180, 240, 320, 400, and 500 mg. For pharmacokinetic analysis, timed blood samples were collected after administration of the single dose and after the first 14 days of continuous daily administration. Dose-limiting toxicity was grade 3 diarrhea, which occurred in one patient treated with 180 mg and in four patients treated with 400 mg neratinib; hence, the maximum tolerated dose was determined to be 320 mg. Other common neratinib-related toxicities included nausea, vomiting, fatigue, and anorexia. Exposure to neratinib was dose dependent, and the pharmacokinetic profile of neratinib supports a once-a-day dosing regimen. Partial response was observed for 8 (32%) of the 25 evaluable patients with breast cancer. Stable disease >or=24 weeks was observed in one evaluable breast cancer patient and 6 (43%) of the 14 evaluable non-small cell lung cancer patients. The maximum tolerated dose of once-daily oral neratinib is 320 mg. The most common neratinib-related toxicity was diarrhea. Antitumor activity was observed in patients with breast cancer who had previous treatment with trastuzumab, anthracyclines, and taxanes, and tumors with a baseline ErbB-2 immunohistochemical staining intensity of 2+ or 3+. The antitumor activity, tolerable toxicity profile, and pharmacokinetic properties of neratinib warrant its further evaluation.

  2. Realization of 3D evaluation algorithm in dose-guided radiotherapy

    International Nuclear Information System (INIS)

    Wang Yu; Li Gui; Wang Dong; Wu Yican; FDS Team

    2012-01-01

    3D evaluation algorithm instead of 2D evaluation method of clinical dose verification is highly needed for dose evaluation in Dose-guided Radiotherapy. 3D evaluation algorithm of three evaluation methods, including Dose Difference, Distance-To-Agreement and 7 Analysis, was realized by the tool of Visual C++ according to the formula. Two plans were designed to test the algorithm, plan 1 was radiation on equivalent water using square field for the verification of the algorithm's correctness; plan 2 was radiation on the emulation head phantom using conformal field for the verification of the algorithm's practicality. For plan 1, the dose difference, in the tolerance range has a pass rate of 100%, the Distance-To-Agreement and 7 analysis was of a pass rate of 100% in the tolerance range, and a pass rate of 99±1% at the boundary of range. For plan 2, the pass rate of algorithm were 88.35%, 100%, 95.07% for the three evaluation methods, respectively. It can be concluded that the 3D evaluation algorithm is feasible and could be used to evaluate 3D dose distributions in Dose-guided Radiotherapy. (authors)

  3. Dose titration to reduce dipyridamole-related headache.

    Science.gov (United States)

    Chang, Yeu-Jhy; Ryu, Shan-Jin; Lee, Tsong-Hai

    2006-01-01

    Combination of low-dose aspirin and modified-release dipyridamole (ASA+MR-DP) provides a significantly increased benefit in stroke prevention over aspirin alone. However, headaches were reported in more patients receiving dipyridamole-containing agents than in those receiving placebo. We undertook a randomized, double-blind, placebo-controlled trial to evaluate which dosing regimens of ASA+MR-DP have better tolerance. This trial randomized 146 patients with a history of ischemic cerebrovascular disease into three groups: placebo (days 1-28), reduced dose (placebo on days 1-4, ASA+MR-DP once daily before bed during days 5-14, and b.i.d. on days 15-28), and regular dose (placebo on days 1-4, and ASA+MR-DP b.i.d. on days 5-28). Using Chinese diary card, headache was assessed as mean cumulated headache (Sigma frequency x intensity/occurrence days x study days) over the study period, and was graded 0-4 according to Cancer Therapy Evaluation Program, Common Toxicity Criteria, Version 2.0. Intent-to-treat patients after randomization was 46 in placebo group, 45, reduced dose, and 49, regular dose. Among commonly reported adverse effects, headache of any grade occurred significantly more in the regular dose group (38.8%), as compared to the other two groups (p < 0.05). Mean cumulated headache was higher (p < 0.05) in the regular dose group than in the reduced group during days 5-14. Of 27 patients who dropped out, 15 (55.6%) were due to headache, which was substantially more in regular dose (8, 53.3%), though the difference was statistically insignificant. Initial reduced dose treatment with ASA+MR-DP may cause fewer headaches than regular dosing, and seems better tolerated by those susceptible to phosphodiesterase inhibitor-induced headache. Copyright 2006 S. Karger AG, Basel.

  4. Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine

    International Nuclear Information System (INIS)

    Arumugam, Sankar; Xing, Aitang; Goozee, Gary; Holloway, Lois

    2013-01-01

    Independent monitor unit verification of intensity-modulated radiation therapy (IMRT) plans requires detailed 3-dimensional (3D) dose verification. The aim of this study was to investigate using a 3D dose engine in a second commercial treatment planning system (TPS) for this task, facilitated by in-house software. Our department has XiO and Pinnacle TPSs, both with IMRT planning capability and modeled for an Elekta-Synergy 6 MV photon beam. These systems allow the transfer of computed tomography (CT) data and RT structures between them but do not allow IMRT plans to be transferred. To provide this connectivity, an in-house computer programme was developed to convert radiation therapy prescription (RTP) files as generated by many planning systems into either XiO or Pinnacle IMRT file formats. Utilization of the technique and software was assessed by transferring 14 IMRT plans from XiO and Pinnacle onto the other system and performing 3D dose verification. The accuracy of the conversion process was checked by comparing the 3D dose matrices and dose volume histograms (DVHs) of structures for the recalculated plan on the same system. The developed software successfully transferred IMRT plans generated by 1 planning system into the other. Comparison of planning target volume (TV) DVHs for the original and recalculated plans showed good agreement; a maximum difference of 2% in mean dose, − 2.5% in D95, and 2.9% in V95 was observed. Similarly, a DVH comparison of organs at risk showed a maximum difference of +7.7% between the original and recalculated plans for structures in both high- and medium-dose regions. However, for structures in low-dose regions (less than 15% of prescription dose) a difference in mean dose up to +21.1% was observed between XiO and Pinnacle calculations. A dose matrix comparison of original and recalculated plans in XiO and Pinnacle TPSs was performed using gamma analysis with 3%/3 mm criteria. The mean and standard deviation of pixels passing

  5. The continual reassessment method: comparison of Bayesian stopping rules for dose-ranging studies.

    Science.gov (United States)

    Zohar, S; Chevret, S

    2001-10-15

    The continual reassessment method (CRM) provides a Bayesian estimation of the maximum tolerated dose (MTD) in phase I clinical trials and is also used to estimate the minimal efficacy dose (MED) in phase II clinical trials. In this paper we propose Bayesian stopping rules for the CRM, based on either posterior or predictive probability distributions that can be applied sequentially during the trial. These rules aim at early detection of either the mis-choice of dose range or a prefixed gain in the point estimate or accuracy of estimated probability of response associated with the MTD (or MED). They were compared through a simulation study under six situations that could represent the underlying unknown dose-response (either toxicity or failure) relationship, in terms of sample size, probability of correct selection and bias of the response probability associated to the MTD (or MED). Our results show that the stopping rules act correctly, with early stopping by using the two first rules based on the posterior distribution when the actual underlying dose-response relationship is far from that initially supposed, while the rules based on predictive gain functions provide a discontinuation of inclusions whatever the actual dose-response curve after 20 patients on average, that is, depending mostly on the accumulated data. The stopping rules were then applied to a data set from a dose-ranging phase II clinical trial aiming at estimating the MED dose of midazolam in the sedation of infants during cardiac catheterization. All these findings suggest the early use of the two first rules to detect a mis-choice of dose range, while they confirm the requirement of including at least 20 patients at the same dose to reach an accurate estimate of MTD (MED). A two-stage design is under study. Copyright 2001 John Wiley & Sons, Ltd.

  6. A double-blind, placebo-controlled, randomised, parallel-group, dose-escalating, repeat dose study in healthy volunteers to evaluate the safety, tolerability, pharmacodynamic effects and pharmacokinetics of the once daily rectal application of NRL001 suppositories for 14 days.

    Science.gov (United States)

    Bell, D; Duffin, A; Jacobs, A; Pediconi, C; Gruss, H J

    2014-03-01

    The 1R,2S stereoisomer of methoxamine hydrochloride, NRL001, is a highly selective α1-adrenoceptor agonist being developed for the local treatment of non-structural faecal incontinence caused by weak internal anal sphincter tone. This study investigated the steady state pharmacokinetics (PK) and safety of 2 g rectal suppositories containing NRL001 in different strengths (7.5, 10, 12.5 or 15 mg). Healthy volunteers aged 18-45 years received 14 daily doses of NRL001 2 g suppositories or matching placebo. In each dose group nine participants received NRL001 and three received placebo. Blood samples to determine NRL001 concentrations were taken on Days 1, 7 and 14. Cardiovascular parameters were collected via electrocardiograms, Holter monitoring (three lead Holter monitor) and vital signs. Forty-eight volunteers were enrolled; 43 completed the study and were included in the PK analysis population. AUC and Cmax broadly increased with increasing dose, Tmax generally occurred between 4.0 and 5.0 h. Although the data did not appear strongly dose proportional, dose proportionality analysis did not provide evidence against dose proportionality as the log(dose) coefficients were not significantly < 1. NRL001 did not accumulate over time for any dose. Increasing NRL001 concentrations were related to changes in vital sign variables, most notably decreased heart rate. The most commonly reported adverse events (AEs) in the active treatment groups were paraesthesia and piloerection. Treatment with NRL001 was generally well tolerated over 14 days once daily dosing and plasma NRL001 did not accumulate over time. Treatment was associated with changes in vital sign variables, most notably decreased heart rate. AEs commonly reported with NRL001 treatment were events indicative of a systemic α-adrenergic effect. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  7. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54–56 Gy given in 9–7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-01-01

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003–2008, 41 patients with 42 lung tumors were treated with SBRT to 54–56 Gy in 9–7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16–48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10–55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures

  8. Tolerance and withdrawal from prolonged opioid use in critically ill children.

    Science.gov (United States)

    Anand, Kanwaljeet J S; Willson, Douglas F; Berger, John; Harrison, Rick; Meert, Kathleen L; Zimmerman, Jerry; Carcillo, Joseph; Newth, Christopher J L; Prodhan, Parthak; Dean, J Michael; Nicholson, Carol

    2010-05-01

    After prolonged opioid exposure, children develop opioid-induced hyperalgesia, tolerance, and withdrawal. Strategies for prevention and management should be based on the mechanisms of opioid tolerance and withdrawal. Relevant manuscripts published in the English language were searched in Medline by using search terms "opioid," "opiate," "sedation," "analgesia," "child," "infant-newborn," "tolerance," "dependency," "withdrawal," "analgesic," "receptor," and "individual opioid drugs." Clinical and preclinical studies were reviewed for data synthesis. Mechanisms of opioid-induced hyperalgesia and tolerance suggest important drug- and patient-related risk factors that lead to tolerance and withdrawal. Opioid tolerance occurs earlier in the younger age groups, develops commonly during critical illness, and results more frequently from prolonged intravenous infusions of short-acting opioids. Treatment options include slowly tapering opioid doses, switching to longer-acting opioids, or specifically treating the symptoms of opioid withdrawal. Novel therapies may also include blocking the mechanisms of opioid tolerance, which would enhance the safety and effectiveness of opioid analgesia. Opioid tolerance and withdrawal occur frequently in critically ill children. Novel insights into opioid receptor physiology and cellular biochemical changes will inform scientific approaches for the use of opioid analgesia and the prevention of opioid tolerance and withdrawal.

  9. Bone and marrow dose modeling

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    2004-01-01

    Nuclear medicine therapy is being used increasingly in the treatment of cancer (thyroid, leukemia/lymphoma with RIT, primary and secondary bone malignancies, and neuroblastomas). In all cases it is marrow toxicity that limits the amount of treatment that can be administered safely. Marrow dose calculations are more difficult than for many major organs because of the intricate association of bone and soft tissue elements. In RIT, there appears to be no consensus on how to calculate that dose accurately, or of individual patients ability to tolerate planned therapy. Available dose models are designed after an idealized average, healthy individual. Patient-specific methods are applied in evaluation of biokinetic data, and need to be developed for treatment of the physical data (dose conversion factors) as well: age, prior patient therapy, disease status. Contributors to marrow dose: electrons and photons

  10. Comparison of once-daily versus twice-daily dosing of valsartan in patients with chronic stable heart failure

    Directory of Open Access Journals (Sweden)

    Inder S Anand

    2010-06-01

    Full Text Available Inder S Anand1, Anita Deswal2, Dean J Kereiakes3, Das Purkayastha4, Dion H Zappe41Veterans Administration Medical Center, Minneapolis, MN, USA; 2Michael E DeBakey VA Medical Center, Houston, TX, USA; 3The Christ Hospital Heart and Vascular Center, Cincinnati, OH, USA; 4Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA; Clinical trial registration information: www.clinicaltrials.gov/ct2/show/NC T00294086 Unique identification number: NC T00294086Background: The safety of once-daily (qd dosing of valsartan in heart failure (HF patients is not known. Hypothesis: This 10-week, double-blind trial examined the relative safety and efficacy of valsartan administered qd versus twice-daily (bid.Methods: HF patients (NYHA class II–III receiving diuretics (87%, angiotensin-converting enzyme inhibitors (98%, beta-blockers (92%, aldosterone antagonists (25%, or digoxin (32% were randomized to valsartan 40 mg bid (n = 60 or 80 mg qd (n = 55 and titrated to a maximum dose of 320 mg/day; doubling the dose every 2 weeks. Clinical and biochemical parameters were measured at Weeks 2, 4, 6, and 10.Results: The average dose of valsartan at the end of study was 245 mg in the bid group vs 256 mg in the qd group (P = NS. Similar proportions of patients tolerated qd vs bid dosing (bid 67% vs qd 68%. Outcome measures including reduction in blood pressure, incidence of hypotension, renal impairment, orthostatic dizziness or fatigue, changes in serum K+, creatinine, cystatin-C, and estimated glomerular filtration rate were similar between the 2 groups at all time-points. Brain natriuretic peptide levels decreased and plasma renin activity increased from baseline by the same amount in both groups at all time-points.Conclusion: Valsartan administered qd has a similar safety and tolerability profile with comparable 24-hour RAAS blockade, as assessed by increases in PRA, as bid dosing in patients with moderate to severe (NYHA class II–III heart failure

  11. Dose distribution at junctional area abutting X-ray and electron fields

    International Nuclear Information System (INIS)

    Yang, Kwang Mo

    2004-01-01

    For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1 Gy) were exposes to 8 cm depth and surface(SSD 100 cm) of phantom. The dose distribution to the junction line between photon(10 x 10 cm field with block) and electron(15 cm x 15 cm field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  12. Medium doses of daily vitamin D decrease falls and higher doses of daily vitamin D3 increase falls: A randomized clinical trial.

    Science.gov (United States)

    Smith, Lynette M; Gallagher, J Christopher; Suiter, Corinna

    2017-10-01

    Falls are a serious health problem in the aging population. Because low levels of vitamin D have been associated with increased fall rates, many trials have been performed with vitamin D; two meta-analyses showed either a small effect or no effect of vitamin D on falls. We conducted a study of the effect of vitamin D on serum 25 hydroxyvitamin D (25OHD) and data on falls was collected as a secondary outcome. In a 12-month double blind randomized placebo trial, elderly women, mean age 66 years, were randomized to one of seven daily oral doses of vitamin D or placebo. The main inclusion criterion for study was a baseline serum 25OHDvitamin D on falls followed a U-shaped curve whether analyzed by dose or serum 25OHD levels. There was no decrease in falls on low vitamin D doses 400, 800 IU, a significant decrease on medium doses 1600, 2400,3200 IU (p=0.020) and no decrease on high doses 4000, 4800 IU compared to placebo (p=0.55). When compared to 12-month serum 25OHD quintiles, the faller rate was 60% in the lowest quintile <25ng/ml (<50nmol/L), 21% in the low middle quintile 32-38ng/ml (80-95nmo/L), 72% in the high middle quintile 38-46ng/ml (95-115nmo/L) and 45% in the highest quintile 46-66ng/ml (115-165nmol/L). In the subgroup with a fall history, fall rates were 68% on low dose, 27% on medium doses and 100% on higher doses. Fall rates on high doses were increased compared to medium doses (Odds Ratio 5.6.95% CI: 2.1-14.8). In summary, the maximum decrease in falls corresponds to a 12- month serum 25OHD of 32-38ng/ml (80-95nmol/L) and faller rates increase as serum 25OHD exceed 40-45ng/ml (100-112.5nmol/L). The Tolerable upper limit (TUL) recently increased in 2010 from 2000 to 4000 IU/day may need to be reduced in elderly women especially in those with a fall history. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    ICRP introduced the concept of Effective Dose Equivalent H(sub)E and fixed the basic limits of radiation exposure in terms of H(sub)I. As H(sub)E cannot be measured, ICRP stated that with external exposure to penetrating radiation the limitation of the Dose Equivalent Index H(sub)I would afford at least as good a level of protection. However, difficulties arise in measuring H(sub)I and in calibrating instruments in terms of H(sub)I, since the height and location of the dose equivalent maximum in the sphere which is the phantom used in the definition of H(sub)I, depend on the energy and the angular distribution of the incident radiation. That is, H(sub)I is not an additive quantity relative to the partial H(sub)I(sub)i-values of the different energy and angular components. Hence, 1) the distribution of dose equivalent in the sphere must be measured in full for a determination of H(sub)I, and 2) it is not possible to calibrate an instrument which does not exhibit the scattering and absorption properties of the sphere, consistently for arbitrary radiation fields in terms of H(sub)I. Thus the calibration in an unidirectional beam would infer an uncertainty which may amount to a factor of up to 4. This would hardly be tolerable as a base for radiation protection provisions. An alternative is to introduce operational quantities which are additive, e.g. 1) the sum of maxima of the dose equivalent distributions in the sphere produced by different radiation components, and 2) the mean dose equivalent in the sphere. Their relation to H(sub)E for different types of radiation and consequences on secondary limits are discussed. (H.K.)

  14. Phase 1 study of the investigational Aurora A kinase inhibitor alisertib (MLN8237) in East Asian cancer patients: pharmacokinetics and recommended phase 2 dose.

    Science.gov (United States)

    Venkatakrishnan, Karthik; Kim, Tae Min; Lin, Chia-Chi; Thye, Lim Soon; Chng, Wee Joo; Ma, Brigette; Chen, Ming Huang; Zhou, Xiaofei; Liu, Hua; Kelly, Virginia; Kim, Won Seog

    2015-08-01

    This phase 1 study assessed the pharmacokinetics (PK), maximum tolerated dose (MTD)/recommended phase 2 dose (RP2D), safety, and preliminary efficacy of the investigational Aurora A kinase inhibitor, alisertib, in East Asian patients with advanced solid tumors or lymphomas. Patients received alisertib twice-daily (BID) for 7 days in 21-day cycles. Doses were escalated (3 + 3) from 30 mg BID based on cycle 1 dose-limiting toxicities (DLTs) until the MTD, followed by expansion for PK/safety characterization. Thirty-six patients (61 % Chinese, 36 % Korean, 3 % Malay) received alisertib (30 mg BID, n = 30; 40 mg BID, n = 6; median, 2.5 cycles). Alisertib exposures increased approximately dose proportionally, and mean half-life was 16 h. Geometric mean apparent oral clearance (2.65 L/h) was 40 % lower than previous estimates in Western patients, resulting in approximately 70 % higher mean dose-normalized, steady-state exposures (735 nM*h/mg) in East Asian patients. Two patients experienced DLTs at 40 mg BID (grade 3 stomatitis; grade 4 neutropenia); the MTD/RP2D was 30 mg BID. Common toxicities (grade ≥3 at RP2D) were neutropenia (50 %), diarrhea (13 %), and stomatitis (10 %). One patient with extranodal T-/NK-cell lymphoma (nasal type) achieved a partial response and 18 (51 %) had stable disease. The MTD/RP2D of alisertib in East Asian patients (30 mg BID) was lower than in Western patients (50 mg BID), consistent with higher systemic exposures in the East Asian population. Alisertib was generally well tolerated and showed signs of antitumor activity in East Asian cancer patients.

  15. Kaempferol Promotes Transplant Tolerance by Sustaining CD4+FoxP3+ Regulatory T Cells in the Presence of Calcineurin Inhibitor.

    Science.gov (United States)

    Zeng, Y Q; Liu, X S; Wu, S; Zou, C; Xie, Q; Xu, S M; Jin, X W; Li, W; Zhou, A; Dai, Z

    2015-07-01

    Calcineurin inhibitor cyclosporine is widely used as an immunosuppressant in clinic. However, mounting evidence has shown that cyclosporine hinders tolerance induction by dampening Tregs. Therefore, it is of paramount importance to overcome this pitfall. Kaempferol was reported to inhibit DC function. Here, we found that kaempferol delayed islet allograft rejection. Combination of kaempferol and low-dose, but not high-dose, of cyclosporine induced allograft tolerance in majority of recipient mice. Although kaempferol plus either dose of cyclosporine largely abrogated proliferation of graft-infiltrating T cells and their CTL activity, both proliferation and CTL activity in mice treated with kaempferol plus low-dose, but not high-dose, cyclosporine reemerged rapidly upon treatment withdrawal. Kaempferol increased CD4+FoxP3+ Tregs both in transplanted mice and in vitro, likely by suppressing DC maturation and their IL-6 expression. Reduction in Tregs by low dose of cyclosporine was reversed by kaempferol. Kaempferol-induced Tregs exhibited both allospecific and non-allospecific suppression. Administering IL-6 abrogated allograft tolerance induced by kaempferol and cyclosporine via diminishing CD4+FoxP3+ Tregs. Thus, for the first time, we demonstrated that kaempferol promotes transplant tolerance in the presence of low dose of cyclosporine, which allows for sufficient Treg generation while minimizing side effects, resulting in much-needed synergy between kaempferol and cyclosporine. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  16. The true bladder dose: on average thrice higher than the ICRU reference

    International Nuclear Information System (INIS)

    Barillot, I.; Horiot, J.C.; Maingon, P.; Bone-Lepinoy, M.C.; D'Hombres, A.; Comte, J.; Delignette, A.; Feutray, S.; Vaillant, D.

    1996-01-01

    The aim of this study is to compare ICRU dose to doses at the bladder base located from ultrasonography measurements. Since 1990, the dose delivered to the bladder during utero-vaginal brachytherapy was systematically calculated at 3 or 4 points representative of bladder base determined with ultrasonography. The ICRU Reference Dose (IRD) from films, the Maximum Dose (Dmax), the Mean Dose (Dmean) representative of the dose received by a large area of bladder mucosa, the Reference Dose Rate (RDR) and the Mean Dose Rate (MDR) were recorded. Material: from 1990 to 1994, 198 measurements were performed in 152 patients. 98 patients were treated for cervix carcinomas, 54 for endometrial carcinomas. Methods: Bladder complications were classified using French Italian Syllabus. The influence of doses and dose rates on complications were tested using non parametric t test. Results: On average IRD is 21 Gy +/- 12 Gy, Dmax is 51Gy +/- 21Gy, Dmean is 40 Gy +/16 Gy. On average Dmax is thrice higher than IRD and Dmean twice higher than IRD. The same results are obtained for cervix and endometrium. Comparisons on dose rates were also performed: MDR is on average twice higher than RDR (RDR 48 cGy/h vs MDR 88 cGy/h). The five observed complications consist of incontinence only (3 G1, 1G2, 1G3). They are only statistically correlated with RDR p=0.01 (46 cGy/h in patients without complications vs 74 cGy/h in patients with complications). However the full responsibility of RT remains doubtful and should be shared with surgery in all cases. In summary: Bladder mucosa seems to tolerate well much higher doses than previous recorded without increased risk of severe sequelae. However this finding is probably explained by our efforts to spare most of bladder mucosa by 1 deg. ) customised external irradiation therapy (4 fields, full bladder) 2 deg. ) reproduction of physiologic bladder filling during brachytherapy by intermittent clamping of the Foley catheter

  17. Radiation doses to normal tissues during craniospinal irradiation ...

    African Journals Online (AJOL)

    Mohamed Farouk Mostafa

    2011-10-15

    Oct 15, 2011 ... not in the center of the brain as this shows lower doses to eyes and lenses. ª 2011 Alexandria .... dose plan function was used to check the dose coverage of the .... maximum dose received by the right and left lens were listed.

  18. Tolerability and safety of antifungal drugs

    Directory of Open Access Journals (Sweden)

    Francesco Scaglione

    2013-08-01

    Full Text Available When treating critically ill patients, as those with fungal infections, attention should be focused on the appropriate use of drugs, especially in terms of dose, safety, and tolerability. The fungal infection itself and the concomitant physiological disorders concur to increase the risk of mortality in these patients, therefore the use of any antifungal agent should be carefully evaluated, considering both the direct action on the target fungus and the adverse effects eventually caused. Among antifungal drugs, echinocandins have the greatest tolerability. In fact, unlike amphotericin B, showing nephrotoxicity, and azoles, which are hepatotoxic, the use of echinocandins doesn’t result in major adverse events.http://dx.doi.org/10.7175/rhc.v4i2s.873

  19. Curcumin Attenuates Opioid Tolerance and Dependence by Inhibiting Ca2+/Calmodulin-Dependent Protein Kinase II α Activity

    Science.gov (United States)

    Hu, Xiaoyu; Huang, Fang; Szymusiak, Magdalena

    2015-01-01

    Chronic use of opioid analgesics has been hindered by the development of opioid addiction and tolerance. We have reported that curcumin, a natural flavonoid from the rhizome of Curcuma longa, attenuated opioid tolerance, although the underlying mechanism remains unclear. In this study, we tested the hypothesis that curcumin may inhibit Ca2+/calmodulin-dependent protein kinase II α (CaMKIIα), a protein kinase that has been previously proposed to be critical for opioid tolerance and dependence. In this study, we used state-of-the-art polymeric formulation technology to produce poly(lactic-co-glycolic acid) (PLGA)-curcumin nanoparticles (nanocurcumin) to overcome the drug’s poor solubility and bioavailability, which has made it extremely difficult for studying in vivo pharmacological actions of curcumin. We found that PLGA-curcumin nanoparticles reduced the dose requirement by 11- to 33-fold. Pretreatment with PLGA-curcumin (by mouth) prevented the development of opioid tolerance and dependence in a dose-dependent manner, with ED50 values of 3.9 and 3.2 mg/kg, respectively. PLGA-curcumin dose-dependently attenuated already-established opioid tolerance (ED50 = 12.6 mg/kg p.o.) and dependence (ED50 = 3.1 mg/kg p.o.). Curcumin or PLGA-curcumin did not produce antinociception by itself or affect morphine (1–10 mg/kg) antinociception. Moreover, we found that the behavioral effects of curcumin on opioid tolerance and dependence correlated with its inhibition of morphine-induced CaMKIIα activation in the brain. These results suggest that curcumin may attenuate opioid tolerance and dependence by suppressing CaMKIIα activity. PMID:25515789

  20. Tolerance of canine portal vein anastomosis to intraoperative X-irradiation

    International Nuclear Information System (INIS)

    Ohara, K.; Takeshima, T.

    1987-01-01

    Tolerance of surgical portal vein anatomosis to intraoperative radiation therapy (IORT) was studied in dogs after single doses of zero, 10, 20 and 40 Gy (290 kVp X-rays). Portal venography was performed prior to IORT and before sacrificing. The dogs were sacrificed 3 and 12 months respectively after irradiation. Portal venography revealed no radiation induced anastomotic stenosis. Autopys disclosed macroscopic periportal fibrosis in all dogs, independent of radiation dose and observation periods. Microscopically, the three tunicas of the vein did not show any pathological changes after any dose level. (orig.)

  1. MAK- and BAT values list 2003. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2003. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The importance, application and derivation of the maximum concentrations at the workplace is explained. A material's list contains the presently valid maximum concentration values supplemented by a list of materials for which no such values were determined as yet. Furthermore there is a list of working materials clearly identified as carcinogenic, and of working materials with a sensitizing effect, aerosols and some specific working materials are discussed. Finally, the importance and the application of biological tolerance values is explained, supplemented by a materials list. (orig.) [German] In der vorliegenden neuesten Ausgabe werden erneut Bedeutung, Benutzung und Ableitung der MAK-Werte (maximale Arbeitsplatzkonzentrationen) erlaeutert. Eine Stoffliste enthaelt die derzeit gueltigen MAK-Werte, ergaenzt durch eine Aufzaehlung von Stoffen, fuer die noch keine MAK-Werte aufgestellt werden koennen. Es folgt eine Auflistung der Arbeitsstoffe, die bereits eindeutig als krebserregend ausgewiesen wurden, sowie der sensibilisierenden Arbeitsstoffe, Aerosole und einige besondere Arbeitsstoffe. Abschliessend wird die Bedeutung und Benutzung der BAT-Werte erlaeutert, ergaenzt durch eine Stoffliste. (orig.)

  2. Hardness, function, emotional well-being, satisfaction and the overall sexual experience in men using 100-mg fixed-dose or flexible-dose sildenafil citrate

    Science.gov (United States)

    Ströberg, P; Kaminetsky, J C; Park, N C; Goldfischer, E R; Creanga, D L; Stecher, V J

    2010-01-01

    The prescribing information for sildenafil citrate (VIAGRA, Pfizer, New York, NY, USA) recommends flexible dosing (50 mg initially, adjusted to 100 or 25 mg based on effectiveness and tolerability) in most men with erectile dysfunction (ED). In many men, however, 100 mg may be the most appropriate initial dose because it would reduce the need for titration and could prevent discouragement and treatment abandonment should 50 mg be insufficient. Results of two previously published double-blind, placebo-controlled sildenafil trials of similar design except for a fixed-dose vs flexible-dose regimen were analyzed. Relative to the flexible-dose, approximately one-third more men were satisfied with an initial and fixed dose of 100 mg. In addition, tolerability was similar, and improvements from baseline in outcomes on validated, ED-specific, patient-reported questionnaires were either similar (erectile function and the percentage of completely hard and fully rigid erections) or greater (emotional well-being and the overall sexual experience). The similarity in outcomes is not surprising given that almost 90% of the men in the flexible-dose trial titrated to 100 mg after 2 weeks. These data suggest prescription of an initial dose of 100 mg for men with ED, except in those for whom it is inappropriate. PMID:20596083

  3. Safety, tolerability, and preliminary activity of CUDC-907, a first-in-class, oral, dual inhibitor of HDAC and PI3K, in patients with relapsed or refractory lymphoma or multiple myeloma: an open-label, dose-escalation, phase 1 trial.

    Science.gov (United States)

    Younes, Anas; Berdeja, Jesus G; Patel, Manish R; Flinn, Ian; Gerecitano, John F; Neelapu, Sattva S; Kelly, Kevin R; Copeland, Amanda R; Akins, Amy; Clancy, Myles S; Gong, Lucy; Wang, Jing; Ma, Anna; Viner, Jaye L; Oki, Yasuhiro

    2016-05-01

    Treatment options for patients with relapsed or refractory lymphoma and multiple myeloma are limited. CUDC-907 is an oral, first-in-class, small molecule that is designed to inhibit both histone deacetylase (HDAC) and PI3K enzymes, which are members of common oncogenic pathways in haematological malignancies. We aimed to assess overall safety and preliminary activity in this dose-escalation study of CUDC-907 monotherapy in patients with relapsed or refractory lymphoma and multiple myeloma. This open-label, first-in-man, phase 1 trial recruited adult patients (aged ≥18 years) with lymphoma or multiple myeloma who were refractory to or had relapsed after two or more previous regimens, from four US cancer centres. CUDC-907 was orally administered in a standard 3 + 3 dose-escalation design at four different dosing schedules, to which participants were sequentially assigned as follows: once daily, intermittently (twice or three times weekly; simultaneous enrolment), and daily for 5 days followed by a 2-day break (5/2), in 21-day cycles. Dosing started at 30 mg for the once-daily schedule and 60 mg for other schedules, escalating in 30 mg increments. Patients continued to receive CUDC-907 until disease progression or until other treatment discontinuation criteria were met. The primary objective was to determine the maximum tolerated dose (MTD) and recommended phase 2 dose, assessed in patients who received at least 66% of cycle 1 doses without modification and those who had a dose-limiting toxicity (DLT) in cycle 1 irrespective of dose modification. We assessed safety in all patients who received at least one dose of study drug. This ongoing trial is registered at ClinicalTrials.gov, number NCT01742988. Between Jan 23, 2013, and July 27, 2015, we enrolled 44 patients, of whom ten were sequentially assigned to CUDC-907 once-daily (MTD 60 mg), 12 to twice-weekly (MTD 150 mg), 15 to three-times-weekly (MTD 150 mg), and seven to the 5/2 dosing schedule (MTD 60 mg). 37

  4. Radiation tolerance of the pig kidney: a model for determining overall time and fraction factors for preserving renal function

    International Nuclear Information System (INIS)

    Hopewell, J.W.

    1975-01-01

    The Ellis Nominal Standard Dose system has attracted clinical interest for estimating irregular treatment schedules in radiotherapy. This study attempts to examine the system applied to renal tolerance in swine by looking for some regular relationship between time, dose, and fractionation. Also examined was renal function up to two years after treatment. These data indicate that renal tolerance may not be predictable by any simple mathematical expression

  5. Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    Science.gov (United States)

    Miften, Moyed; Olch, Arthur; Mihailidis, Dimitris; Moran, Jean; Pawlicki, Todd; Molineu, Andrea; Li, Harold; Wijesooriya, Krishni; Shi, Jie; Xia, Ping; Papanikolaou, Nikos; Low, Daniel A

    2018-04-01

    Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review aimed at improving the understanding and consistency of these processes as well as recommendations for methodologies and tolerance limits in patient-specific IMRT QA. The performance of the dose difference/distance-to-agreement (DTA) and γ dose distribution comparison metrics are investigated. Measurement methods are reviewed and followed by a discussion of the pros and cons of each. Methodologies for absolute dose verification are discussed and new IMRT QA verification tools are presented. Literature on the expected or achievable agreement between measurements and calculations for different types of planning and delivery systems are reviewed and analyzed. Tests of vendor implementations of the γ verification algorithm employing benchmark cases are presented. Operational shortcomings that can reduce the γ tool accuracy and subsequent effectiveness for IMRT QA are described. Practical considerations including spatial resolution, normalization, dose threshold, and data interpretation are discussed. Published data on IMRT QA and the clinical experience of the group members are used to develop guidelines and recommendations on tolerance and action limits for IMRT QA. Steps to check failed IMRT QA plans are outlined. Recommendations on delivery methods, data interpretation, dose normalization, the use of γ analysis routines and choice of tolerance limits for IMRT QA are made with focus on detecting differences between calculated and measured doses via the use of robust analysis methods and an in-depth understanding of IMRT verification metrics. The recommendations are intended to improve the IMRT QA process and establish consistent, and comparable IMRT QA

  6. Comparative bioavailability and tolerability of a single 20-mg dose of two fluoxetine hydrochloride dispersible tablet formulations in fasting, healthy Chinese male volunteers: an open-label, randomized-sequence, two-period crossover study.

    Science.gov (United States)

    Shi, Shaojun; Liu, Yani; Wu, Jianhong; Li, Zhongfang; Zhao, Yan; Zhong, Dafang; Zeng, Fandian

    2010-10-01

    The proprietary formulation of fluoxetine hydrochloride is an antidepressant of the selective serotonin reuptake inhibitor class. Pharmacokinetic studies investigating the bioequivalence of generic and branded formulations are needed to market generic fluoxetine in China. The aim of this study was to compare the bioavailability and tolerability of the proposed generic formulation with the established reference formulation of fluoxetine hydrochloride 20 mg in a fasting, healthy Chinese male population. This 10-week, open-label, randomized-sequence, single-dose, 2-period crossover study was conducted in healthy native Han Chinese male volunteers. Eligible subjects were randomly assigned in a 1:1 ratio to receive a single 20-mg dose of the test or reference formulation, followed by a 35-day washout period and administration of the alternate formulation. Doses were administered after a 12-hour overnight fast. For analysis of pharmacokinetic properties (including C(max), T(max), AUC(0-t), AUC(0-∞), and t(½)), blood samples were obtained over a 672-hour period after dosing. Plasma concentrations of fluoxetine and its active metabolite, norfluoxetine, were analyzed using a validated LC-MS/MS method. The formulations were to be considered bioequivalent if the ln-transformed ratios (test/ reference) of C(max) and AUC were within the predetermined bioequivalence range of 80% to 125%, as established by the US Food and Drug Administration, and if the P values were fasting, healthy Chinese male volunteers. Both formulations appeared to be well tolerated. Copyright © 2010 Excerpta Medica Inc. All rights reserved.

  7. Hyperfractionated abdominal radiotherapy in children. Efficacy and tolerance in 13 cases

    International Nuclear Information System (INIS)

    Lagrange, J.L.; Roullet, B.; Cosset, J.M.; Sarrazin, D.; Lemerle, J.

    1984-01-01

    The experience at IGR has shown that hyperfractionation, especially abdominal has been well tolerated in adult patients. This finding led to employ this technic in the pediatric population who had failed standard treatment. An experience with hyperfractionated radiotherapy of the abdomen and liver in children, is reported. The children were treated 4 days per week, receiving 5 fractions daily of 0.7 Gy, with a 2 hours interval between each treatment. A total dose of 28 Gy was delivered in 40 fractions over 12 days. A second course of irradiation was delivered in 5 patients, 3 with abdominal treatment and 2 with liver irradiation. The vital organs were shielded with blocks at normal dose tolerance levels. The results are encouraging since an immediate efficacy was observed in 8 of 13 patients. Long term survivals were observed in 4 patients with nephroblastomas and 1 patient with a hepatoblastoma. On the other hand acute gastrointestinal tolerance seemed less good in the children than previously observed in the adults. Five radiation hepatitis appeared, immediately after the irradiation, whom four children irradiated to the entire abdomen [fr

  8. Tolerance and withdrawal to anticonvulsant action of clonazepam: role of nitric oxide.

    Science.gov (United States)

    Gupta, N; Bhargava, V K; Pandhi, P

    2000-05-01

    The use of clonazepam in the long-term treatment of epilepsy is greatly inhibited by its capacity to induce tolerance and dependence. A means of preventing or minimizing the tolerance and dependence inducing properties is required. Here the role of nitric oxide in preventing the development of tolerance and withdrawal hyperexcitability was studied. In Wistar rats, clonazepam at a dose of 0.25 mg/kg i.p. twice daily produced tolerance to its anticonvulsant action in 28 days. After sudden cessation of therapy it produced hyperexcitability. Tolerance was shown by a decrease in seizure threshold to near control value while withdrawal hyperexcitability was evidenced by a significant decrease in seizure threshold below the control value. L-Arginine (a donor of nitric oxide) and N omega-nitro-L-arginine (an inhibitor of nitric oxide synthase) were given in doses of 150 mg/kg and 8 mg/kg, respectively on day 1, 3, 7, 14, 21 and 28 with clonazepam. Withdrawal hyperexcitability was seen on day 1, 2 and 4 after cessation of drug therapy. Electroshock was used as a model of epilepsy and seizure thresholds were determined by an up and down method of Kimball et al. L-Arginine was found to inhibit the development tolerance as well as withdrawal hyperexcitability when administered with clonazepam while N omega-L-arginine did not prevent either the development of tolerance or withdrawal hyperexcitability in the electroshock model. In the PTZ model, however, L-arginine had no effect on the anticonvulsant action and withdrawal hyperexcitability while inhibition of nitric oxide synthesis prevented withdrawal hyperexcitability in PTZ-induced seizures.

  9. Late effects of radiation on the lumbar spinal cord of guinea pigs: Re-treatment tolerance

    International Nuclear Information System (INIS)

    Mason, K.A.; Withers, H.R.; Chiang, Chi-Shiun

    1993-01-01

    Using a guinea pig model of lumbar myelopathy, various factors affecting the tolerance of spinal cord to irradiation were assessed: (a) extent of initial injury; (b) time interval between priming and test doses; and (c) animal age at the time of initial radiation treatment. A 3 cm section of lumbar spinal cord of guinea pigs was irradiated with fractionated doses of 4.5 Gy gamma rays given as 9 fractions per week. Guinea pigs were primed with 9 x 4.5 Gy in 7 days which is 60% of the ED 50 for a continuous course of treatment. After 28 or 40 weeks, animal were retreated with 6-14 fractions of 4.5 Gy. Animals were observed for 2 years following the priming dose and both the incidence and latency of myelopathy recorded. Young adult guinea pigs (8 wk old) showed both a decreased radiation tolerance and latency compared to old individuals (40 wk old). At 28 or 40 wk after 9 x 4.5 Gy, only about 8% of the initial injury was remembered in young adult guinea pigs. The amount of residual injury was dependent on the initial damage as a proportion of the tolerance dose. The spinal cord shows a greater capacity for long-term recovery than generally appreciated and re-treatment doses clinically prescribed may be lower than necessary. 8 refs., 3 figs., 2 tabs

  10. Phase I clinical studies of the advanced glycation end-product (AGE)-breaker TRC4186: safety, tolerability and pharmacokinetics in healthy subjects.

    Science.gov (United States)

    Chandra, Kumar P; Shiwalkar, Ajay; Kotecha, Jignesh; Thakkar, Purav; Srivastava, Ambrish; Chauthaiwale, Vijay; Sharma, Sanjay K; Cross, Maurice R; Dutt, Chaitanya

    2009-01-01

    -blind, placebo-controlled, single-dose, dose-ascending study in elderly male and female subjects at a dose of TRC4186 500 mg followed by TRC4186 1000 mg after a 7-day washout period. The safety and tolerability of TRC4186 were assessed by considering adverse events (AEs), ECG findings, vital signs and laboratory investigation results. TRC4186 was rapidly absorbed, with maximum plasma concentrations (C(max)) attained within 1-4 hours. C(max) and area under the plasma concentration-time curve (AUC) were dose proportional over the range 250-2500 mg for a single dose and 500-2000 mg for multiple doses with twice-daily administration. Steady-state conditions were attained within 6 days at different dose levels. C(max) and AUC were not affected by age, sex, race or type of formulation. The tablet formulation of TRC4186 was bioequivalent with the solution form of the drug under fasting conditions and systemic availability of the tablet formulation was reduced by 40% when administered under fed conditions. Terminal elimination and renal clearance in the elderly male (age 69.1 +/- 6.0 years) were not significantly different compared with younger subjects (age 31 +/- 8.6 years). TRC4186 was safe and well tolerated when administered orally with either a single or multiple doses across the different ages, sexes, races and formulations studied. A dose-proportional increase in plasma TRC4186 concentration was seen, with steady state being achieved within 6 days.

  11. Dose estimates in Japan following the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Togawa, Orihiko; Homma, Toshimitsu; Iijima, Toshinori; Midorikawa, Yuji.

    1988-02-01

    Estimates have been made of the maximum individual doses and the collective doses in Japan following the Chernobyl reactor accident. Based on the measured data of ground deposition and radionuclide concentrations in air, raw milk, milk on sale and leafy vegetables, the doses from some significant radionuclides were calculated for 5 typical exposure pathways; cloudshine, groundshine, inhalation, ingestion of milk and leafy vegetables. The maximum effective dose equivalents for hypothetical individuals were calculated to be 1.8 mrem for adults, 3.7 mrem for children and 6.0 mrem for infants. The collective effective dose equivalent in Japan was estimated to be 5.8 x 10 4 man · rem; 0.50 mrem of the average dose per capita. (author)

  12. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  13. Robot-borne fault tolerant calculators for nuclear use

    International Nuclear Information System (INIS)

    Giraud, A.; Robiolle, M.

    1995-01-01

    The use of robots has become a necessity in civil nuclear industry. Electronic systems of such robots must tolerate cumulative ionizing radiation dose effects. Today's objective is to reach a 3 kGy dose resistance. Difficulties and costs involved during on-site maintenance imply to warrant at least one functioning mode in the case of system failure. To improve the behaviour of robot-borne systems, the CEA Department for Nuclear Engineering Studies (DEIN) has developed a method for the selection of industrial electronic components and has built computer architectures which allows to break free from some cumulative dose sensitive parameters. This paper presents the MICADO and CADMOS architectures developed at the DEIN. (J.S.). 15 refs., 5 figs

  14. Super-low dose endotoxin pre-conditioning exacerbates sepsis mortality.

    Science.gov (United States)

    Chen, Keqiang; Geng, Shuo; Yuan, Ruoxi; Diao, Na; Upchurch, Zachary; Li, Liwu

    2015-04-01

    Sepsis mortality varies dramatically in individuals of variable immune conditions, with poorly defined mechanisms. This phenomenon complements the hypothesis that innate immunity may adopt rudimentary memory, as demonstrated in vitro with endotoxin priming and tolerance in cultured monocytes. However, previous in vivo studies only examined the protective effect of endotoxin tolerance in the context of sepsis. In sharp contrast, we report herein that pre-conditionings with super-low or low dose endotoxin lipopolysaccharide (LPS) cause strikingly opposite survival outcomes. Mice pre-conditioned with super-low dose LPS experienced severe tissue damage, inflammation, increased bacterial load in circulation, and elevated mortality when they were subjected to cecal-ligation and puncture (CLP). This is in opposite to the well-reported protective phenomenon with CLP mice pre-conditioned with low dose LPS. Mechanistically, we demonstrated that super-low and low dose LPS differentially modulate the formation of neutrophil extracellular trap (NET) in neutrophils. Instead of increased ERK activation and NET formation in neutrophils pre-conditioned with low dose LPS, we observed significantly reduced ERK activation and compromised NET generation in neutrophils pre-conditioned with super-low dose LPS. Collectively, our findings reveal a novel mechanism potentially responsible for the dynamic programming of innate immunity in vivo as it relates to sepsis risks.

  15. Super-low Dose Endotoxin Pre-conditioning Exacerbates Sepsis Mortality

    Directory of Open Access Journals (Sweden)

    Keqiang Chen

    2015-04-01

    Full Text Available Sepsis mortality varies dramatically in individuals of variable immune conditions, with poorly defined mechanisms. This phenomenon complements the hypothesis that innate immunity may adopt rudimentary memory, as demonstrated in vitro with endotoxin priming and tolerance in cultured monocytes. However, previous in vivo studies only examined the protective effect of endotoxin tolerance in the context of sepsis. In sharp contrast, we report herein that pre-conditioning with super-low or low dose endotoxin lipopolysaccharide (LPS cause strikingly opposite survival outcomes. Mice pre-conditioned with super-low dose LPS experienced severe tissue damage, inflammation, increased bacterial load in circulation, and elevated mortality when they were subjected to cecal-ligation and puncture (CLP. This is in contrast to the well-reported protective phenomenon with CLP mice pre-conditioned with low dose LPS. Mechanistically, we demonstrated that super-low and low dose LPS differentially modulate the formation of neutrophil extracellular trap (NET in neutrophils. Instead of increased ERK activation and NET formation in neutrophils pre-conditioned with low dose LPS, we observed significantly reduced ERK activation and compromised NET generation in neutrophils pre-conditioned with super-low dose LPS. Collectively, our findings reveal a mechanism potentially responsible for the dynamic programming of innate immunity in vivo as it relates to sepsis risks.

  16. A phase I dose-escalation study of lenalidomide in combination with gemcitabine in patients with advanced pancreatic cancer.

    Directory of Open Access Journals (Sweden)

    Gustav J Ullenhag

    Full Text Available Lenalidomide have both immunomodulatory and anti-angiogenic properties which could confer anti-cancer effects. The aim of this study was to assess the feasibility of combining lenalidomide with the standard treatment gemcitabine in pancreatic cancer patients with advanced disease.Eligible patients had locally advanced or metastatic adenocarcinoma of the pancreas. Patients received lenalidomide days 1-21 orally and gemcitabine 1000 mg/m2 intravenously (days 1, 8 and 15, each 28 day cycle. Three cohorts of lenalidomide were examined (Cohort I = 15 mg, Cohort II = 20 mg and Cohort III = 25 mg daily. The maximum tolerated dose (MTD of lenalidomide given in combination with gemcitabine was defined as the highest dose level at which no more than one out of four (25% subjects experiences a dose-limiting toxicity (DLT. Patients should also be able to receive daily low molecular weight heparin (LMWH (e.g. dalteparin 5000 IU s.c. daily as a prophylactic anticoagulant for venous thromboembolic events (VTEs. Twelve patients (n = 4, n = 3 and n = 5 in cohort I, II and III, respectively were enrolled in this study.Median duration of treatment was 11 weeks (range 1-66, and median number of treatment cycles were three (range 1-14. The only DLT was a cardiac failure grade 3 in cohort III. Frequent treatment-related adverse events (AEs (all grades included neutropenia, leucopenia and fatigue (83% each, but there was no febrile neutropenia; thrombocytopenia (75%; dermatological toxicity (75%; diarrhea and nausea (42% each; and neuropathy (42%.This phase I study demonstrates the feasibility of the combination of lenalidomide and gemcitabine as first-line treatment in patients with advanced pancreatic cancer. The tolerability profile demonstrated in the dose escalation schedule of lenalidomide suggests the dosing of lenalidomide to be 25 mg daily on days 1-21 with standard dosing of gemcitabine and merits further evaluation in a phase II trial.ClinicalTrials.gov NCT

  17. Center of cancer systems biology second annual workshop--tumor metronomics: timing and dose level dynamics.

    Science.gov (United States)

    Hahnfeldt, Philip; Hlatky, Lynn; Klement, Giannoula Lakka

    2013-05-15

    Metronomic chemotherapy, the delivery of doses in a low, regular manner so as to avoid toxic side effects, was introduced over 12 years ago in the face of substantial clinical and preclinical evidence supporting its tumor-suppressive capability. It constituted a marked departure from the classic maximum-tolerated dose (MTD) strategy, which, given its goal of rapid eradication, uses dosing sufficiently intense to require rest periods between cycles to limit toxicity. Even so, upfront tumor eradication is frequently not achieved with MTD, whereupon a de facto goal of longer-term tumor control is often pursued. As metronomic dosing has shown tumor control capability, even for cancers that have become resistant to the same drug delivered under MTD, the question arises whether it may be a preferable alternative dosing approach from the outset. To date, however, our knowledge of the coupled dynamics underlying metronomic dosing is neither sufficiently well developed nor widely enough disseminated to establish its actual potential. Meeting organizers thus felt the time was right, armed with new quantitative approaches, to call a workshop on "Tumor Metronomics: Timing and Dose Level Dynamics" to explore prospects for gaining a deeper, systems-level appreciation of the metronomics concept. The workshop proved to be a forum in which experts from the clinical, biologic, mathematical, and computational realms could work together to clarify the principles and underpinnings of metronomics. Among other things, the need for significant shifts in thinking regarding endpoints to be used as clinical standards of therapeutic progress was recognized. ©2013 AACR.

  18. Dose-volume considerations in stereotaxic brain radiation therapy

    International Nuclear Information System (INIS)

    Houdek, P.V.; Schwade, J.G.; Pisciotta, V.J.; Medina, A.J.; Lewin, A.A.; Abitbol, A.A.; Serago, C.F.

    1988-01-01

    Although brain radiation therapy experience suggests that a gain in the therapeutic ratio may be achieved by optimizing the dose-volume relationship, no practical system for quantitative assessment of dose-volume data has been developed. This presentation describes the rationale for using the integral dose function for this purpose and demonstrates that with the use of a conventional treatment planning computer and a series of computed tomographic scans, first-order optimization of the dose-volume function can be accomplished in two steps: first, high-dose volume is minimized by selecting an appropriate treatment technique and tumor margin, and then dosage is maximized by calculating the brain tolerance dose as a function of the irradiated volume

  19. Response of human lymphocytes to low gamma ray doses

    International Nuclear Information System (INIS)

    Vega Carrillo, HR; Banuelos Valenzuela, R; Manzanares Acuna, E; Sanchez-Rodriguez, S.H

    2001-01-01

    Radiation and non-radiation workers lymphocytes were exposed to a low strength gamma-ray field to determine heat shock protein expression in function of radiation dose. Protein identification was carried out using mAb raised against Hsp25, Hsp60, Hsp70 and Hsp90; from these, only Hsp70 protein was detected before and after lymphocyte irradiation. In all cases, an increasing trend of relative amounts of Hsp70 in function to irradiation time was observed. After 70.5 mGy gamma-ray dose, radiation worker's lymphocytes expressed more Hsp70 protein, than non-radiation workers' lymphocytes, indicating a larger tolerance to gamma rays (gamma tolerance), due to an adaptation process developed by their labor condition (Au)

  20. Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Adkison, Jarrod B.; McHaffie, Derek R.; Bentzen, Soren M.; Patel, Rakesh R.; Khuntia, Deepak [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Petereit, Daniel G. [Department of Radiation Oncology, John T. Vucurevich Regional Cancer Care Institute, Rapid City Regional Hospital, Rapid City, SD (United States); Hong, Theodore S.; Tome, Wolfgang [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Ritter, Mark A., E-mail: ritter@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States)

    2012-01-01

    Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose

  1. Influence of intravenous opioid dose on postoperative ileus.

    Science.gov (United States)

    Barletta, Jeffrey F; Asgeirsson, Theodor; Senagore, Anthony J

    2011-07-01

    Intravenous opioids represent a major component in the pathophysiology of postoperative ileus (POI). However, the most appropriate measure and threshold to quantify the association between opioid dose (eg, average daily, cumulative, maximum daily) and POI remains unknown. To evaluate the relationship between opioid dose, POI, and length of stay (LOS) and identify the opioid measure that was most strongly associated with POI. Consecutive patients admitted to a community teaching hospital who underwent elective colorectal surgery by any technique with an enhanced-recovery protocol postoperatively were retrospectively identified. Patients were excluded if they received epidural analgesia, developed a major intraabdominal complication or medical complication, or had a prolonged workup prior to surgery. Intravenous opioid doses were quantified and converted to hydromorphone equivalents. Classification and regression tree (CART) analysis was used to determine the dosing threshold for the opioid measure most associated with POI and define high versus low use of opioids. Risk factors for POI and prolonged LOS were determined through multivariate analysis. The incidence of POI in 279 patients was 8.6%. CART analysis identified a maximum daily intravenous hydromorphone dose of 2 mg or more as the opioid measure most associated with POI. Multivariate analysis revealed maximum daily hydromorphone dose of 2 mg or more (p = 0.034), open surgical technique (p = 0.045), and days of intravenous narcotic therapy (p = 0.003) as significant risk factors for POI. Variables associated with increased LOS were POI (p POI and prolonged LOS, particularly when the maximum hydromorphone dose per day exceeds 2 mg. Clinicians should consider alternative, nonopioid-based pain management options when this occurs.

  2. Single-dose and steady-state pharmacokinetics of tenofovir disoproxil fumarate in human immunodeficiency virus-infected children.

    Science.gov (United States)

    Hazra, Rohan; Balis, Frank M; Tullio, Antonella N; DeCarlo, Ellen; Worrell, Carol J; Steinberg, Seth M; Flaherty, John F; Yale, Kitty; Poblenz, Marianne; Kearney, Brian P; Zhong, Lijie; Coakley, Dion F; Blanche, Stephane; Bresson, Jean Louis; Zuckerman, Judith A; Zeichner, Steven L

    2004-01-01

    Tenofovir disoproxil fumarate (DF) is a potent nucleotide analog reverse transcriptase inhibitor approved for the treatment of human immunodeficiency virus (HIV)-infected adults. The single-dose and steady-state pharmacokinetics of tenofovir were evaluated following administration of tenofovir DF in treatment-experienced HIV-infected children requiring a change in antiretroviral therapy. Using increments of tenofovir DF 75-mg tablets, the target dose was 175 mg/m(2); the median administered dose was 208 mg/m(2). Single-dose pharmacokinetics were evaluated in 18 subjects, and the geometric mean area under the concentration-time curve from 0 h to infinity (AUC(0- infinity )) was 2,150 ng. h/ml and the geometric mean maximum concentration (C(max)) was 266 ng/ml. Subsequently, other antiretrovirals were added to each patient's regimen based upon treatment history and baseline viral resistance results. Steady-state pharmacokinetics were evaluated in 16 subjects at week 4. The steady-state, geometric mean AUC for the 24-h dosing interval was 2,920 ng. h/ml and was significantly higher than the AUC(0- infinity ) after the first dose (P = 0.0004). The geometric mean C(max) at steady state was 302 ng/ml. Tenofovir DF was generally very well tolerated. Steady-state tenofovir exposures in children receiving tenofovir DF-containing combination antiretroviral therapy approached values seen in HIV-infected adults (AUC, approximately 3,000 ng. h/ml; C(max), approximately 300 ng/ml) treated with tenofovir DF at 300 mg.

  3. Comparative study of eye dose and chest dose received during radiopharmaceutical production processes

    International Nuclear Information System (INIS)

    Chindarkar, A.S.; Chavan, S.V.; Sawant, D.K.; Sahoo, L.; Gopalakrishnan, R.K.; Sneha, C.; Sachdev, S.S.; Dey, A.C.

    2018-01-01

    Radiopharmaceutical laboratory, BRIT, Vashi produces different radiopharmaceuticals of 131 I, 153 Sm, 99 Mo/ 99m Tc and 177 Lu. Principle gamma energies of these isotopes vary from 103 to 740 KeV and their maximum beta energies vary from 384 to 1214 KeV. In the light of the revised eye lens dose limit recommended in IAEA Basic Safety Standard Interim Edition No. GSR Part 3 (IAEA-2011), the study of radiation dose for eye lens was carried out using CaSO 4 : Dy based Thermo luminescence dosimeter (TLD). This TLD was worn at center of the forehead to measure eye lens dose. This TLD dose was then compared with chest TLD dose to deduce any correlation between these TLD doses. These TLD doses were assessed on quarterly basis. Eight quarter data of these TLD doses were compared

  4. Radiation tolerant design - theory and practice for proximity sensing

    International Nuclear Information System (INIS)

    Sharp, R.E.; Pater, S.L.; Cook, J.

    1999-01-01

    This paper provides a description of the radiation tolerant design process used to develop a range of proximity detectors with guaranteed total dose lifetime. It also describes some of the applications in which the detectors are being used and the benefits gained by plant operators. (authors)

  5. SU-G-201-14: Is Maximum Skin Dose a Reliable Metric for Accelerated Partial Breast Irradiation with Brachytherapy?

    International Nuclear Information System (INIS)

    Park, S; Ragab, O; Patel, S; Demanes, J; Kamrava, M; Kim, Y

    2016-01-01

    Purpose: To evaluate the reliability of the maximum point dose (Dmax) to the skin surface as a dosimetric constraint, we investigated the correlation between Dmax at the skin surface and dose metrics at various definitions of skin thickness. Methods: 42 patients treated with APBI using a Strut Adjusted Volume Implant (SAVI) applicator between 2010 and 2014 were retrospectively reviewed. Target (PTV-EVAL) and organs at risk (OARs: skin, lung, and ribs) were delineated on a CT following NSABP B-39 guidelines. Six skin structures were contoured: a rind 3cm external to the body surface and 1, 2, 3, 4, and 5mm thick rinds deep to the body surface. Inverse planning simulated annealing optimization was used to deliver 32–34Gy in 8-10 fractions to the target while minimizing OAR doses. Dmax, D0.1cc, D1.0cc, and D2.0cc to the various skin structures were calculated. Linear regressions between the metrics were evaluated using the coefficient of determination (R"2). Results: The average±SD PTV-EVAL volume and cavity-to-skin distances were 71.1±28.5cc and 6.9±5.0mm. The target V90 and V95 were 97.3±2.3% and 95.1±3.2%. The Dmax to the skin structures were 78.7±10.2% (skin surface), 82.2±10.7% (skin-1mm), 89.4±12.6% (skin-2mm), 97.9±15.4% (skin-3mm), 114.1±32.5% (skin-4mm), and 157.0±85.3% (skin-5mm). Linear regression analysis showed D1.0cc and D2.0cc to the skin 1mm and Dmax to the skin-4mm and 5mm were poorly correlated with other metrics (R"2=0.413±0.204). Dmax to the skin surface was well correlated (R"2=0.910±0.047) and D1.0cc to the skin-3mm was strongly correlated with all subsurface skin layers (R"2=0.935±0.050). Conclusion: Dmax to the skin surface is a relevant metric for breast skin dose. Contouring discontinuities in the skin with a 1mm subsurface rind and the active dwells in the skin 4 and 5mm introduced significant variations in skin DVH. D0.1cc, D1.0cc, and D2.0cc to a 3mm skin rind are more robust metrics in breast brachytherapy.

  6. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  7. Exploratory study to evaluate tolerability, safety, and activity of Ashwagandha (Withania somnifera in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Ashwinikumar A Raut

    2012-01-01

    Full Text Available Ashwagandha (Withania somnifera (WS, a "rasayana" drug, is recommended for balavardhan and mamsavardhan. The study was intended to evaluate dose-related tolerability, safety, and activity of WS formulation in normal individuals. The design was prospective, open-labeled, variable doses in volunteers. Eighteen apparently healthy volunteers (12M:6F, age:18-30 years, and BMI: 19-30 were enrolled. After baseline investigations, they received WS capsules (Rx (aqueous extract, 8:1 daily in two divided doses with increase in daily dosage every 10 days for 30 days (750 mg/day x10 days, 1 000 mg/day x 10 days, 1 250 mg/day x 10 days. Volunteers were assessed for symptoms/signs, vital functions, hematological and biochemical organ function tests. Muscle activity was measured by hand grip strength, quadriceps strength, and back extensor force. Exercise tolerance was determined using cycle ergometry. Lean body weight and fat% were computed from skin fold thickness measurement. Adverse events were recorded, as volunteered by the subjects. Repeated measures ANOVA, McNemar′s test, and paired t test were employed. All but one volunteer tolerated WS without any adverse event. One volunteer showed increased appetite, libido, and hallucinogenic effects with vertigo at the lowest dose and was withdrawn from study. In six subjects, improvement in quality of sleep was found. Organ function tests were in normal range before and after the intervention. Reduction in total- and LDL- cholesterol and increase of strength in muscle activity was significant. Total body fat percentage showed a reduction trend. WS, in escalated dose, was tolerated well. The formulation appeared safe and strengthened muscle activity. In view of its traditional Rasayana use, further studies are planned to evaluate potential of this drug in patients of sarcopenia.

  8. Oral glucose tolerance test performance in olanzapine-treated schizophrenia-spectrum patients is predicted by BMI and triglycerides but not olanzapine dose or duration.

    Science.gov (United States)

    Guina, Jeffrey; Roy, Sayon; Gupta, Ankur; Langleben, Daniel D; Elman, Igor

    2017-07-01

    Olanzapine, an atypical antipsychotic, is associated with glucoregulatory abnormalities, but the nature of this link is not fully elucidated. This is the first olanzapine oral glucose tolerance test (oGTT) study to consider treatment dose and duration, and to compare complementary indices respectively assessing insulin sensitivity (Matsuda index) and resistance (homeostasis model assessment). Body mass index (BMI), body composition, plasma lipids, and oGTT were measured in olanzapine-treated nondiabetic patients with DSM-IV-TR diagnosis of schizophrenia or schizoaffective disorder (n = 35). While only one previously undiagnosed participant met diabetes criteria based on fasting plasma glucose alone (≥126 mg/dL), seven were diagnosed with oGTT (2-hr plasma glucose ≥200 mg/dL). Multiple regression analyses revealed that the Matsuda index correlated with BMI (p triglycerides (p = 0.01), but not with age, olanzapine dose, olanzapine treatment duration, or plasma cholesterol. Homeostasis model assessment and fasting plasma glucose correlated with triglycerides only (p triglycerides may be implicated in olanzapine-related glucoregulatory abnormalities. The lack of correlation between glucoregulatory abnormalities and olanzapine dose or treatment duration suggests preexisting metabolic disturbances and/or disturbances arising early in the course of treatment. Clinicians prescribing antipsychotics should consider oGTT, especially in patients with obesity and/or hypertriglyceridemia. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Skin dose estimation due to a contamination by a radionuclide β emitter: are doses equivalent good estimator of protection quantities?

    International Nuclear Information System (INIS)

    Bourgois, L.

    2011-01-01

    When handling radioactive β emitters, measurements in terms of personal dose equivalents H p (0.07) are used to estimate the equivalent dose limit to skin or extremities given by regulations. First of all, analytical expressions for individual dose equivalents H p (0.07) and equivalent doses to the extremities H skin are given for a point source and for contamination with a radionuclide β emitter. Second of all, operational quantities and protection quantities are compared. It is shown that in this case the operational quantities significantly overstate the protection quantities. For a skin contamination the ratio between operational quantities and protection quantities is 2 for a maximum β energy of 3 MeV and 90 for a maximum β energy of 150 keV. (author)

  10. Dose calibrators quality controls in Switzerland: six years of experience

    International Nuclear Information System (INIS)

    Bochud, F.; Spring, Ph.; Baechler, S.; Twerenbold, D.; Linder, R.; Leibundgut, F.

    2006-01-01

    In Switzerland, the legal use of open radioactive sources in nuclear medicine and the general requirements for quality controls are defined in a federal ordinance. The metrological traceability is guaranteed through a directive of the Swiss metrological office (M.E.T.A.S.) that requires each instrument to be monitored at least once a year through either a verification or an intercomparison. The verification is performed onsite by an accredited laboratory with a set of three gamma sources (Co-57, Cs-137 and Co-60) and - if applicable - a beta source (Sr-90/Y- 90). The intercomparison is made through conventional mail. A source of I-131 or Tc- 99 m is measured both in the nuclear medicine department and in an accredited laboratory. The maximum tolerated error is 10% for gamma sources and 20% for beta sources. This methodology guarantees that the instruments have a correct response for most of the energy range used in practice. Not all nuclides are systematically probed and manufacturers are ultimately responsible for the calibration factors. The precision of the measurements performed in Switzerland is satisfactory with only about 6% of the measurements out of the tolerances. This monitoring also allowed us to improve the skills of the personnel and update the park of instruments by getting rid of dose calibrators displaying old units. (authors)

  11. Dose calibrators quality controls in Switzerland: six years of experience

    Energy Technology Data Exchange (ETDEWEB)

    Bochud, F.; Spring, Ph.; Baechler, S. [Institut Universitaire de Radiophysique Appliquee, Lausanne (Switzerland); Twerenbold, D. [METAS, Lindenweg 50, Bern-Wabern (Switzerland); Linder, R. [Bundesamt fur Gesundheit, Abteilung Strahlenschutz, Bern (Switzerland); Leibundgut, F. [Raditec radiation and technology, Schoftland (Switzerland)

    2006-07-01

    In Switzerland, the legal use of open radioactive sources in nuclear medicine and the general requirements for quality controls are defined in a federal ordinance. The metrological traceability is guaranteed through a directive of the Swiss metrological office (M.E.T.A.S.) that requires each instrument to be monitored at least once a year through either a verification or an intercomparison. The verification is performed onsite by an accredited laboratory with a set of three gamma sources (Co-57, Cs-137 and Co-60) and - if applicable - a beta source (Sr-90/Y- 90). The intercomparison is made through conventional mail. A source of I-131 or Tc- 99 m is measured both in the nuclear medicine department and in an accredited laboratory. The maximum tolerated error is 10% for gamma sources and 20% for beta sources. This methodology guarantees that the instruments have a correct response for most of the energy range used in practice. Not all nuclides are systematically probed and manufacturers are ultimately responsible for the calibration factors. The precision of the measurements performed in Switzerland is satisfactory with only about 6% of the measurements out of the tolerances. This monitoring also allowed us to improve the skills of the personnel and update the park of instruments by getting rid of dose calibrators displaying old units. (authors)

  12. 76 FR 5696 - Fluazifop-P-butyl; Pesticide Tolerances

    Science.gov (United States)

    2011-02-02

    ...: This regulation establishes tolerances for residues of fluazifop-P-butyl in or on multiple commodities... based on maternal body weight gain decrement during GD 7- 16. Incidental oral intermediate- NOAEL= 0.74....0 and 2% at 200 mg dose.) mg/kg/day based on fetal UFA = 10x weight decrement, UFH = 10x hydroureter...

  13. A Randomized Dose-Ranging Study of Neuropeptide Y in Patients with Posttraumatic Stress Disorder.

    Science.gov (United States)

    Sayed, Sehrish; Van Dam, Nicholas T; Horn, Sarah R; Kautz, Marin M; Parides, Michael; Costi, Sara; Collins, Katherine A; Iacoviello, Brian; Iosifescu, Dan V; Mathé, Aleksander A; Southwick, Steven M; Feder, Adriana; Charney, Dennis S; Murrough, James W

    2018-01-01

    Anxiety and trauma-related disorders are among the most prevalent and disabling medical conditions in the United States, and posttraumatic stress disorder in particular exacts a tremendous public health toll. We examined the tolerability and anxiolytic efficacy of neuropeptide Y administered via an intranasal route in patients with posttraumatic stress disorder. Twenty-six individuals were randomized in a cross-over, single ascending dose study into 1 of 5 cohorts: 1.4 mg (n=3), 2.8 mg (n=6), 4.6 mg (n=5), 6.8 mg (n=6), and 9.6 mg (n=6). Each individual was dosed with neuropeptide Y or placebo on separate treatment days 1 week apart in random order under double-blind conditions. Assessments were conducted at baseline and following a trauma script symptom provocation procedure subsequent to dosing. Occurrence of adverse events represented the primary tolerability outcome. The difference between treatment conditions on anxiety as measured by the Beck Anxiety Inventory and the State-Trait Anxiety Inventory immediately following the trauma script represented efficacy outcomes. Twenty-four individuals completed both treatment days. Neuropeptide Y was well tolerated up to and including the highest dose. There was a significant interaction between treatment and dose; higher doses of neuropeptide Y were associated with a greater treatment effect, favoring neuropeptide Y over placebo on Beck Anxiety Inventory score (F1,20=4.95, P=.038). There was no significant interaction for State-Trait Anxiety Inventory score. Our study suggests that a single dose of neuropeptide Y is well tolerated up to 9.6 mg and may be associated with anxiolytic effects. Future studies exploring the safety and efficacy of neuropeptide Y in stress-related disorders are warranted. The reported study is registered at: http://clinicaltrials.gov (ID: NCT01533519). © The Author(s) 2017. Published by Oxford University Press on behalf of CINP.

  14. Simulation of aspheric tolerance with polynomial fitting

    Science.gov (United States)

    Li, Jing; Cen, Zhaofeng; Li, Xiaotong

    2018-01-01

    The shape of the aspheric lens changes caused by machining errors, resulting in a change in the optical transfer function, which affects the image quality. At present, there is no universally recognized tolerance criterion standard for aspheric surface. To study the influence of aspheric tolerances on the optical transfer function, the tolerances of polynomial fitting are allocated on the aspheric surface, and the imaging simulation is carried out by optical imaging software. Analysis is based on a set of aspheric imaging system. The error is generated in the range of a certain PV value, and expressed as a form of Zernike polynomial, which is added to the aspheric surface as a tolerance term. Through optical software analysis, the MTF of optical system can be obtained and used as the main evaluation index. Evaluate whether the effect of the added error on the MTF of the system meets the requirements of the current PV value. Change the PV value and repeat the operation until the acceptable maximum allowable PV value is obtained. According to the actual processing technology, consider the error of various shapes, such as M type, W type, random type error. The new method will provide a certain development for the actual free surface processing technology the reference value.

  15. Optimization of tolerability and efficacy of the novel dual amylin and calcitonin receptor agonist KBP-089 through dose escalation and combination with a GLP-1 analog

    DEFF Research Database (Denmark)

    Gydesen, Sofie; Andreassen, Kim Vietz; Hjuler, Sara Toftegaard

    2017-01-01

    , and the following treatment with 2.5, 10, and 40 µg/kg resulted in an ~15% vehicle-corrected weight loss, a corresponding reduction in adipose tissue (AT), and, in all treatment groups, improved oral glucose tolerance (P weight evenly with no significant...... second day obtained equal weight loss at study end, albeit with an uneven reduction in both food intake and body weight in rats dosed every second day. In a 4-fold dose escalation, KBP-089 induced a transient reduction in food intake at every escalation step, with reducing magnitude over time...... reduction in food intake at either escalation step. KBP-089 (1.25 µg/kg) and liraglutide (50 µg/kg) reduced 24-h food intake by 29% and 37% compared with vehicle, respectively; however, when they were combined, 24-h food intake was reduced by 87%. Chronically, KBP-089 (1.25 µg/kg) and liraglutide (50 µg...

  16. A Phase I/II Trial of Intensity Modulated Radiation (IMRT) Dose Escalation With Concurrent Fixed-dose Rate Gemcitabine (FDR-G) in Patients With Unresectable Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Josef, Edgar, E-mail: edgar.ben-josef@uphs.upenn.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Schipper, Mathew [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Francis, Isaac R. [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Hadley, Scott; Ten-Haken, Randall; Lawrence, Theodore; Normolle, Daniel [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Simeone, Diane M.; Sonnenday, Christopher [Department of Surgery, University of Michigan, Ann Arbor, Michigan (United States); Abrams, Ross [Department of Radiation Oncology, Rush Medical Center, Chicago, Illinois (United States); Leslie, William [Division of Hematology Oncology, Department of Internal Medicine, Rush Medical Center, Chicago, Illinois (United States); Khan, Gazala; Zalupski, Mark M. [Division of Hematology Oncology, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States)

    2012-12-01

    Purpose: Local failure in unresectable pancreatic cancer may contribute to death. We hypothesized that intensification of local therapy would improve local control and survival. The objectives were to determine the maximum tolerated radiation dose delivered by intensity modulated radiation with fixed-dose rate gemcitabine (FDR-G), freedom from local progression (FFLP), and overall survival (OS). Methods and Materials: Eligibility included pathologic confirmation of adenocarcinoma, radiographically unresectable, performance status of 0-2, absolute neutrophil count of {>=}1500/mm{sup 3}, platelets {>=}100,000/mm{sup 3}, creatinine <2 mg/dL, bilirubin <3 mg/dL, and alanine aminotransferase/aspartate aminotransferase {<=}2.5 Multiplication-Sign upper limit of normal. FDR-G (1000 mg/m{sup 2}/100 min intravenously) was given on days -22 and -15, 1, 8, 22, and 29. Intensity modulated radiation started on day 1. Dose levels were escalated from 50-60 Gy in 25 fractions. Dose-limiting toxicity was defined as gastrointestinal toxicity grade (G) {>=}3, neutropenic fever, or deterioration in performance status to {>=}3 between day 1 and 126. Dose level was assigned using TITE-CRM (Time-to-Event Continual Reassessment Method) with the target dose-limiting toxicity (DLT) rate set to 0.25. Results: Fifty patients were accrued. DLTs were observed in 11 patients: G3/4 anorexia, nausea, vomiting, and/or dehydration (7); duodenal bleed (3); duodenal perforation (1). The recommended dose is 55 Gy, producing a probability of DLT of 0.24. The 2-year FFLP is 59% (95% confidence interval [CI]: 32-79). Median and 2-year overall survival are 14.8 months (95% CI: 12.6-22.2) and 30% (95% CI 17-45). Twelve patients underwent resection (10 R0, 2 R1) and survived a median of 32 months. Conclusions: High-dose radiation therapy with concurrent FDR-G can be delivered safely. The encouraging efficacy data suggest that outcome may be improved in unresectable patients through intensification of local

  17. A dose escalation study of concurrent chemoradiation therapy with nedaplatin for cervical cancer

    International Nuclear Information System (INIS)

    Hatae, Masayuki; Takahashi, Takeshi; Kodama, Shoji

    2005-01-01

    Doses of nedaplatin (CDGP) were established for concurrent chemoradiation therapy (CCRT) for cervical cancer, and a collaborative dose escalation study involving 8 hospitals was conducted to investigate the safety and efficacy of this therapy. Radiotherapy was performed according to the standard treatment described in the Regulations of Cervical Carcinoma Treatment. CDGP at 80 mg/m 2 as Level 1 or at 90 mg/m 2 as Level 2 was administered on Days 1 and 29 of treatment. Dose-limiting toxicity (DLT) was observed in 1 of 6 patients receiving 80 mg/m 2 of CDGP and in all 2 patients receiving 90 mg/m 2 of CDGP; therefore, Level 2 was regarded as the maximum tolerated dose (MTD), and Level 1 as the recommended dose. DLT signs consisted of delayed improvement in the leukocyte count in 2 patients and anorexia in 1 patient, suggesting that delayed improvement in the leukocyte count is the main DLT of this combination therapy. The main side effects were digestive disorders such as nausea and anorexia and bone marrow suppression, such as leukopenia, neutropenia, and thrombopenia. Side effects in the Level 1 group were more mild than in the Level 2 group. The efficacy was partial response (PR) or better in all patients. The complete response (CR) rates were 60% (6/10) in the Level 1 group and 50% (1/2) in the Level 2 group; there was no marked difference between the two groups. These results suggest that CCRT involving administration CDGP at 80 mg/m 2 on Days 1 and 29 is safe and effective. (author)

  18. Tolerance to Gamma Radiation in the Tardigrade Hypsibius dujardini from Embryo to Adult Correlate Inversely with Cellular Proliferation.

    Directory of Open Access Journals (Sweden)

    Eliana Beltrán-Pardo

    Full Text Available Tardigrades are highly tolerant to desiccation and ionizing radiation but the mechanisms of this tolerance are not well understood. In this paper, we report studies on dose responses of adults and eggs of the tardigrade Hypsibius dujardini exposed to gamma radiation. In adults the LD50/48h for survival was estimated at ~ 4200 Gy, and doses higher than 100 Gy reduced both fertility and hatchability of laid eggs drastically. We also evaluated the effect of radiation (doses 50 Gy, 200 Gy, 500 Gy on eggs in the early and late embryonic stage of development, and observed a reduced hatchability in the early stage, while no effect was found in the late stage of development. Survival of juveniles from irradiated eggs was highly affected by a 500 Gy dose, both in the early and the late stage. Juveniles hatched from eggs irradiated at 50 Gy and 200 Gy developed into adults and produced offspring, but their fertility was reduced compared to the controls. Finally we measured the effect of low temperature during irradiation at 4000 Gy and 4500 Gy on survival in adult tardigrades, and observed a slight delay in the expressed mortality when tardigrades were irradiated on ice. Since H. dujardini is a freshwater tardigrade with lower tolerance to desiccation compared to limno-terrestrial tardigrades, the high radiation tolerance in adults, similar to limno-terrestrial tardigrades, is unexpected and seems to challenge the idea that desiccation and radiation tolerance rely on the same molecular mechanisms. We suggest that the higher radiation tolerance in adults and late stage embryos of H. dujardini (and in other studied tardigrades compared to early stage embryos may partly be due to limited mitotic activity, since tardigrades have a low degree of somatic cell division (eutely, and dividing cells are known to be more sensitive to radiation.

  19. A Review Of Fault Tolerant Scheduling In Multicore Systems

    Directory of Open Access Journals (Sweden)

    Shefali Malhotra

    2015-05-01

    Full Text Available Abstract In this paper we have discussed about various fault tolerant task scheduling algorithm for multi core system based on hardware and software. Hardware based algorithm which is blend of Triple Modulo Redundancy and Double Modulo Redundancy in which Agricultural Vulnerability Factor is considered while deciding the scheduling other than EDF and LLF scheduling algorithms. In most of the real time system the dominant part is shared memory.Low overhead software based fault tolerance approach can be implemented at user-space level so that it does not require any changes at application level. Here redundant multi-threaded processes are used. Using those processes we can detect soft errors and recover from them. This method gives low overhead fast error detection and recovery mechanism. The overhead incurred by this method ranges from 0 to 18 for selected benchmarks. Hybrid Scheduling Method is another scheduling approach for real time systems. Dynamic fault tolerant scheduling gives high feasibility rate whereas task criticality is used to select the type of fault recovery method in order to tolerate the maximum number of faults.

  20. Predicted allowable doses to normal organs for biologically targeted radiotherapy

    International Nuclear Information System (INIS)

    O'Donoghue, J.A.; Wheldon, T.E.; Western Regional Hospital Board, Glasgow

    1988-01-01

    The authors have used Dale's extension to the ''linear quadratic'' (LQ) model (Dale, 1985) to evaluate ''equivalent doses'' in cases involving exponentially decaying dose rates. This analysis indicates that the dose-rate effect will be a significant determinant of allowable doses to organs such as liver, kidney and lung. These organ tolerance doses constitute independent constraints on the therapeutic intensity of biologically targeted radiotherapy in exactly the same way as for conventional external beam radiotherapy. In the context of marrow rescue they will in all likelihood constitute the dose-limiting side-effects and thus be especially important. (author)

  1. Quantum money with nearly optimal error tolerance

    Science.gov (United States)

    Amiri, Ryan; Arrazola, Juan Miguel

    2017-06-01

    We present a family of quantum money schemes with classical verification which display a number of benefits over previous proposals. Our schemes are based on hidden matching quantum retrieval games and they tolerate noise up to 23 % , which we conjecture reaches 25 % asymptotically as the dimension of the underlying hidden matching states is increased. Furthermore, we prove that 25 % is the maximum tolerable noise for a wide class of quantum money schemes with classical verification, meaning our schemes are almost optimally noise tolerant. We use methods in semidefinite programming to prove security in a substantially different manner to previous proposals, leading to two main advantages: first, coin verification involves only a constant number of states (with respect to coin size), thereby allowing for smaller coins; second, the reusability of coins within our scheme grows linearly with the size of the coin, which is known to be optimal. Last, we suggest methods by which the coins in our protocol could be implemented using weak coherent states and verified using existing experimental techniques, even in the presence of detector inefficiencies.

  2. Pharmacokinetics, pharmacodynamics, tolerability, and safety of exenatide in Japanese patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Kothare, Prajakti A; Linnebjerg, Helle; Isaka, Yoshitaka; Uenaka, Kazunori; Yamamura, Ayuko; Yeo, Kwee Poo; de la Peña, Amparo; Teng, Choo Hua; Mace, Kenneth; Fineman, Mark; Shigeta, Hirofumi; Sakata, Yukikuni; Irie, Shin

    2008-12-01

    In this single-blind, parallel, placebo-controlled study, the pharmacokinetics, pharmacodynamics, tolerability, and safety of subcutaneous exenatide were evaluated in 40 Japanese patients with type 2 diabetes. Patients were allocated to 4 groups and randomized to receive exenatide (n = 8/group) or placebo (n = 2/group), with all receiving placebo on day 1. On day 2, patients received single-dose exenatide (2.5 microg [group A] or 5 microg [groups B, C, and D]) or placebo and then bid on days 3 to 5. On days 6 to 10, groups A and B continued on 2.5 and 5 microg bid; groups C and D received 10 and 15 microg bid, respectively. The last dose was given on the morning of day 10. All adverse events were mild or moderate in severity. Exenatide was generally well tolerated up to 10 microg. Exenatide was well absorbed with a median t(max) of 1.5 hours and mean t((1/2)) of 1.6 hours; exposure increased with dose. Up to 10 microg, exenatide reduced postprandial glucose concentrations in a dose-dependent fashion compared with placebo; decreases were similar for 10 and 15 microg. An E(max) model demonstrated that doses higher than 2.5 microg were necessary for adequate glycemic response. Based on tolerability and pharmacokinetic/pharmacodynamic relationships, 5 and 10 microg exenatide may be considered for further clinical development in Japanese patients with type 2 diabetes.

  3. Dissipation of excess photosynthetic energy contributes to salinity tolerance: a comparative study of salt-tolerant Ricinus communis and salt-sensitive Jatropha curcas.

    Science.gov (United States)

    Lima Neto, Milton C; Lobo, Ana K M; Martins, Marcio O; Fontenele, Adilton V; Silveira, Joaquim Albenisio G

    2014-01-01

    The relationships between salt tolerance and photosynthetic mechanisms of excess energy dissipation were assessed using two species that exhibit contrasting responses to salinity, Ricinus communis (tolerant) and Jatropha curcas (sensitive). The salt tolerance of R. communis was indicated by unchanged electrolyte leakage (cellular integrity) and dry weight in leaves, whereas these parameters were greatly affected in J. curcas. The leaf Na+ content was similar in both species. Photosynthesis was intensely decreased in both species, but the reduction was more pronounced in J. curcas. In this species biochemical limitations in photosynthesis were more prominent, as indicated by increased C(i) values and decreased Rubisco activity. Salinity decreased both the V(cmax) (in vivo Rubisco activity) and J(max) (maximum electron transport rate) more significantly in J. curcas. The higher tolerance in R. communis was positively associated with higher photorespiratory activity, nitrate assimilation and higher cyclic electron flow. The high activity of these alternative electron sinks in R. communis was closely associated with a more efficient photoprotection mechanism. In conclusion, salt tolerance in R. communis, compared with J. curcas, is related to higher electron partitioning from the photosynthetic electron transport chain to alternative sinks. Copyright © 2013 Elsevier GmbH. All rights reserved.

  4. SU-F-T-301: Planar Dose Pass Rate Inflation Due to the MapCHECK Measurement Uncertainty Function

    International Nuclear Information System (INIS)

    Bailey, D; Spaans, J; Kumaraswamy, L; Podgorsak, M

    2016-01-01

    Purpose: To quantify the effect of the Measurement Uncertainty function on planar dosimetry pass rates, as analyzed with Sun Nuclear Corporation analytic software (“MapCHECK” or “SNC Patient”). This optional function is toggled on by default upon software installation, and automatically increases the user-defined dose percent difference (%Diff) tolerance for each planar dose comparison. Methods: Dose planes from 109 IMRT fields and 40 VMAT arcs were measured with the MapCHECK 2 diode array, and compared to calculated planes from a commercial treatment planning system. Pass rates were calculated within the SNC analytic software using varying calculation parameters, including Measurement Uncertainty on and off. By varying the %Diff criterion for each dose comparison performed with Measurement Uncertainty turned off, an effective %Diff criterion was defined for each field/arc corresponding to the pass rate achieved with MapCHECK Uncertainty turned on. Results: For 3%/3mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.8–1.1% average, depending on plan type and calculation technique, for an average pass rate increase of 1.0–3.5% (maximum +8.7%). For 2%, 2 mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.7–1.2% average, for an average pass rate increase of 3.5–8.1% (maximum +14.2%). The largest increases in pass rate are generally seen with poorly-matched planar dose comparisons; the MapCHECK Uncertainty effect is markedly smaller as pass rates approach 100%. Conclusion: The Measurement Uncertainty function may substantially inflate planar dose comparison pass rates for typical IMRT and VMAT planes. The types of uncertainties incorporated into the function (and their associated quantitative estimates) as described in the software user’s manual may not accurately estimate realistic measurement uncertainty for the user’s measurement conditions. Pass rates listed in published

  5. SU-F-T-301: Planar Dose Pass Rate Inflation Due to the MapCHECK Measurement Uncertainty Function

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, D [Northside Hospital Cancer Institute, Atlanta, GA (United States); Spaans, J; Kumaraswamy, L; Podgorsak, M [Roswell Park Cancer Institute, Buffalo, NY (United States)

    2016-06-15

    Purpose: To quantify the effect of the Measurement Uncertainty function on planar dosimetry pass rates, as analyzed with Sun Nuclear Corporation analytic software (“MapCHECK” or “SNC Patient”). This optional function is toggled on by default upon software installation, and automatically increases the user-defined dose percent difference (%Diff) tolerance for each planar dose comparison. Methods: Dose planes from 109 IMRT fields and 40 VMAT arcs were measured with the MapCHECK 2 diode array, and compared to calculated planes from a commercial treatment planning system. Pass rates were calculated within the SNC analytic software using varying calculation parameters, including Measurement Uncertainty on and off. By varying the %Diff criterion for each dose comparison performed with Measurement Uncertainty turned off, an effective %Diff criterion was defined for each field/arc corresponding to the pass rate achieved with MapCHECK Uncertainty turned on. Results: For 3%/3mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.8–1.1% average, depending on plan type and calculation technique, for an average pass rate increase of 1.0–3.5% (maximum +8.7%). For 2%, 2 mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.7–1.2% average, for an average pass rate increase of 3.5–8.1% (maximum +14.2%). The largest increases in pass rate are generally seen with poorly-matched planar dose comparisons; the MapCHECK Uncertainty effect is markedly smaller as pass rates approach 100%. Conclusion: The Measurement Uncertainty function may substantially inflate planar dose comparison pass rates for typical IMRT and VMAT planes. The types of uncertainties incorporated into the function (and their associated quantitative estimates) as described in the software user’s manual may not accurately estimate realistic measurement uncertainty for the user’s measurement conditions. Pass rates listed in published

  6. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

    Energy Technology Data Exchange (ETDEWEB)

    Gerard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, Francois; Aletti, Pierre [Research Center for Automatic Control (CRAN), Nancy University, CNRS, 54516 Vandoeuvre-les-Nancy (France); Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France) and DOSIsoft SA, 94230 Cachan (France); Research Laboratory for Innovative Processes (ERPI), Nancy University, EA 3767, 5400 Nancy Cedex (France); Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France); DOSIsoft SA, 94230 Cachan (France); Research Center for Automatic Control (CRAN), Nancy University, CNRS, 54516 Vandoeuvre-les-Nancy, France and Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France)

    2009-04-15

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculating a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should

  7. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC).

    Science.gov (United States)

    Gérard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, François; Aletti, Pierre

    2009-04-01

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short-term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center (+/- 4% of deviation between the calculated and measured doses) by calculating a control process capability (C(pc)) index. The C(pc) index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short-term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the

  8. Gamma irradiation facilities for radiation tolerance assessment of components and systems at SCK.CEN

    International Nuclear Information System (INIS)

    Coenen, S.; Decreton, M.

    1999-01-01

    This paper presents the different gamma irradiation facilities available at SCK-CEN (Mol, Belgium). With gamma dose rates ranging from 1 Gy/h up to 50 kGy/h, extensive environmental control and on-line instrumentation possibilities, they offer ideal test environments for the radiation tolerance assessment of components and systems for many applications where radiation tolerance is a concern. (authors)

  9. 78 FR 6213 - Styrene-2-Ethylhexyl Acrylate Copolymer; Tolerance Exemption

    Science.gov (United States)

    2013-01-30

    ...This regulation establishes an exemption from the requirement of a tolerance for residues of 2-propenoic acid, 2-ethylhexyl ester, polymer with ethenylbenzene; also known as styrene-2-ethylhexyl acrylate copolymer when used as an inert ingredient in a pesticide chemical formulation. H. B. Fuller Company submitted a petition to EPA under the Federal Food, Drug, and Cosmetic Act (FFDCA), requesting an exemption from the requirement of a tolerance. This regulation eliminates the need to establish a maximum permissible level for residues of 2-propenoic acid, 2-Ethylhexyl Ester, Polymer with Ethenylbenzene on food or feed commodities.

  10. The small-molecule TNF-α inhibitor, UTL-5g, delays deaths and increases survival rates for mice treated with high doses of cisplatin.

    Science.gov (United States)

    Shaw, Jiajiu; Media, Joseph; Chen, Ben; Valeriote, Fredrick

    2013-09-01

    UTL-5g is a novel small-molecule chemoprotector that lowers hepatotoxicity, nephrotoxicity, and myelotoxicity induced by cisplatin through TNF-α inhibition among other factors. The objective of this study was to investigate whether UTL-5g can reduce the overall acute toxicity of cisplatin and increase cisplatin tolerability in mice. BDF1 female mice were treated individually with UTL-5g (suspended in Ora-Plus) by oral gavage at 60 mg/kg, 30 min before i.p. injection of cisplatin at 10, 15, and 20 mg/kg, respectively, on Day 0. Starting from Day 1, individual mice were again treated daily by the same dose of UTL-5g for 4 consecutive days. Survivals and body weights were monitored. UTL-5g treatment increased the survival rate and delayed the time to death for mice treated with 150 % of the maximum tolerated dose (MTD) of cisplatin (15 mg/kg). Likewise, at 200 % of the MTD of cisplatin (20 mg/kg), treatment of UTL-5g increased the survival rate and delayed the time to death. Treatment of UTL-5g did not have a significant effect on weight loss induced by cisplatin, indicating that body weight may not be a sensitive-enough measure for chemoprotection of UTL-5g against cisplatin. In summary, UTL-5g delayed deaths and increased survival rates of mice treated by high doses of cisplatin, indicating that UTL-5g is capable of reducing the overall acute toxicity of cisplatin and increased cisplatin tolerability in mice; this is in line with the specific chemoprotective effects of UTL-5g previously reported. Further investigation of UTL-5g in combination with cisplatin is warranted.

  11. Considerations on the establishment of maximum permissible exposure of man

    International Nuclear Information System (INIS)

    Jacobi, W.

    1974-01-01

    An attempt is made in the information lecture to give a quantitative analysis of the somatic radiation risk and to illustrate a concept to fix dose limiting values. Of primary importance is the limiting values. Of primary importance is the limiting value of the radiation exposure to the whole population. By consequential application of the risk concept, the following points are considered: 1) Definition of the risk for radiation late damages (cancer, leukemia); 2) relationship between radiation dose and thus caused radiation risk; 3) radiation risk and the dose limiting values at the time; 4) criteria for the maximum acceptable radiation risk; 5) limiting value which can be expected at the time. (HP/LH) [de

  12. Tolerance analysis in manufacturing using process capability ratio with measurement uncertainty

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Mansourvar, Zahra; Hansen, Hans Nørgaard

    2017-01-01

    . In this paper, a new statistical analysis was applied to manufactured products to assess achieved tolerances when the process is known while using capability ratio and expanded uncertainty. The analysis has benefits for process planning, determining actual precision limits, process optimization, troubleshoot......Tolerance analysis provides valuable information regarding performance of manufacturing process. It allows determining the maximum possible variation of a quality feature in production. Previous researches have focused on application of tolerance analysis to the design of mechanical assemblies...... malfunctioning existing part. The capability measure is based on a number of measurements performed on part’s quality variable. Since the ratio relies on measurements, elimination of any possible error has notable negative impact on results. Therefore, measurement uncertainty was used in combination with process...

  13. Dose-volume correlation in radiation-related late small-bowel complication

    International Nuclear Information System (INIS)

    Letschert, J.G.J.; Lebesque, J.V.; Boer, R.W. de; hart, A.A.M.; Barteling, H.

    1990-01-01

    The effects of the volume of irradiated small bowel on late small-bowel tolerance was studied, taking into account the equivalent total dose ant type of pre-irradiation surgical procedure. A method was developed to estimate small-bowel volumes in the high-bowel volumes were measured for three-field and AP-PA pelvic treatments (165 cm 3 and 400 cm 3 , respectively), extended AP-PA treatment of para-aortic and iliac nodes (1000 cm 3 ). In a retrospective study of 111 patientst irradiated after surgery for rectal or recto-sigmoid cancer to a dose of 45-50 Gy in 5 weeks, extended AP-PA pelvic treatment (n = 27) resulted in a high incidence of severe small-bowel complications (37%), whereas for limited (three-field) pelvic treatment (n = 84) the complication rate was 6%. These complication data together with data from the literature on postoperative radiation-related small-bowel complications were analysed using the maximum likelihood method to fit the data to the logistic form of the dose-response relation, taking the volume effect into account by a power law. The analysis indicated that the incidence of radiation-related small-bowel compllications was higher after rectal surgery than after other types of surgery, which might be explained by the development of more adhesions. For both types of surgery a volume exponent of the power-law of 0.26 ± 0.05 was established. This means that if the small-bowel volume is increased by a factor of 2, the total dose has to be reduced by 17% for the same incidence of small-bowel complications. (author). 45 refs.; 6 figs.; 4 tabs

  14. Optimization of dose distributions for adjuvant locoregional radiotherapy of gastric cancer by IMRT

    International Nuclear Information System (INIS)

    Lohr, F.; Dobler, B.; Mai, S.; Hermann, B.; Tiefenbacher, U.; Wieland, P.; Steil, V.; Wenz, F.

    2003-01-01

    Background and Purpose: Locoregional relapse is a problem frequently encountered with advanced gastric cancer. Data from the randomized Intergroup trial 116 suggest effectiveness of adjuvant radiochemotherapy, albeit with significant toxicity. The potential of intensity-modulated radiotherapy (IMRT) to reduce toxicity by significantly reducing maximum and median doses to organs at risk while still applying sufficient dose to the target volume in the upper abdomen was studied. Patient and Methods: For a typical configuration of target volumes and organs, a step-and-shoot IMRT plan (eight beam orientations), developed as a class solution for treatment of tumors in the upper abdomen (Figures 1 to 3), a conventional plan, a combination of the conventional plan with a kidney-sparing boost plan, and a conventional plan with noncoplanar ap and pa fields for improved kidney sparing were compared with respect to coverage of target volume and dose to organs at risk with a dose of 45 Gy delivered as the median dose to the target volume. Results: When using the conventional three-dimensionally planned box techniques, the right kidney could be kept below tolerance, but median dose to the left kidney amounted to between 14.8 and 26.9 Gy, depending on the plan. IMRT reduced the median dose to the left kidney to 10.5 Gy, while still keeping the dose to the right kidney 90% of prescription dose were delivered to > 90% of target volume with IMRT (Table 1). Conclusion: IMRT has the potential to deliver efficient doses to target volumes in the upper abdomen, while delivering dose to organs at risk in a more advantageous fashion than a conventional technique. For clinical implementation, the possibility of extensive organ motion in the upper abdomen has to be taken into account for treatment planning and patient positioning. The multitude of potential risks related to its application has to be the subject of thorough follow-up and further studies. (orig.)

  15. Estimation of eye lens doses received by pediatric interventional cardiologists.

    Science.gov (United States)

    Alejo, L; Koren, C; Ferrer, C; Corredoira, E; Serrada, A

    2015-09-01

    Maximum Hp(0.07) dose to the eye lens received in a year by the pediatric interventional cardiologists has been estimated. Optically stimulated luminescence dosimeters were placed on the eyes of an anthropomorphic phantom, whose position in the room simulates the most common irradiation conditions. Maximum workload was considered with data collected from procedures performed in the Hospital. None of the maximum values obtained exceed the dose limit of 20 mSv recommended by ICRP. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Modulation of morphine antinociceptive tolerance and physical dependence by co-administration of simvastatin.

    Science.gov (United States)

    Mansouri, Mohammad Taghi; Khodayar, Mohammad Javad; Tabatabaee, Amirhossein; Ghorbanzadeh, Behnam; Naghizadeh, Bahareh

    2015-10-01

    Statins, 3-hydroxy-3-methylglutaryl co-enzyme A (HMG-CoA) reductase inhibitors, are widely used in the management of different diseases beyond their primary indication for lowering cholesterol. Previous studies have demonstrated the neuroprotective effects of simvastatin in different animal models. In the present study, we examined the effects of simvastatin (30, 60, 100 and 300mg/kg, p.o.) on the development and expression of morphine-induced tolerance and dependence in mice. For the induction of morphine tolerance and dependence, mice were twice daily treated with morphine (10mg/kg, s.c.) for 5 consecutive days. Tolerance was evaluated by the hot-plate test and physical dependence by naloxone challenge, on the sixth day. The results showed that oral administration of simvastatin produced antinociceptive activity in a dose-dependent way. Co-administration of simvastatin with morphine did not affect the acute morphine-induced analgesia (10mg/kg, s.c.). However, repeated co-administration of simvastatin with morphine significantly attenuated the development of tolerance to the analgesic effect of morphine and inhibited the naloxone (5mg/kg, s.c.)-precipitated withdrawal signs (jumping and body weight loss). Also, simvastatin at doses of 100 and 300mg/kg attenuated the expression of morphine-induced tolerance and dependence. These data indicated that, while simvastatin can alleviate both development and expression of morphine-induced tolerance, it cannot enhance morphine-induced antinociception. Taken together, simvastatin may be used as an adjutant therapeutic agent in combination with morphine and or other opioids in patients with severe chronic pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Improved metabolic control in tetrahydrobiopterin (BH4), responsive phenylketonuria with sapropterin administered in two divided doses vs. a single daily dose.

    Science.gov (United States)

    Kör, Deniz; Yılmaz, Berna Şeker; Bulut, Fatma Derya; Ceylaner, Serdar; Mungan, Neslihan Önenli

    2017-07-26

    Phenylketonuria (PKU) often requires a lifelong phenylalanine (Phe)-restricted diet. Introduction of 6R-tetrahydrobiopterin (BH4) has made a huge difference in the diets of patients with PKU. BH4 is the co-factor of the enzyme phenylalanine hydroxylase (PAH) and improves PAH activity and, thus, Phe tolerance in the diet. A limited number of published studies suggest a pharmacodynamic profile of BH4 more suitable to be administered in divided daily doses. After a 72-h BH4 loading test, sapropterin was initiated in 50 responsive patients. This case-control study was conducted by administering the same daily dose of sapropterin in group 1 (n=24) as a customary single dose or in two divided doses in group 2 (n=26) over 1 year. Mean daily consumption of Phe increased significantly after the first year of BH4 treatment in group 2 compared to group 1 (p<0.05). At the end of the first year of treatment with BH4, another dramatic difference observed between the two groups was the ability to transition to a Phe-free diet. Eight patients from group 2 and two from group 1 could quit dietary restriction. When given in two divided daily doses, BH4 was more efficacious than a single daily dose in increasing daily Phe consumption, Phe tolerance and the ability to transition to a Phe-unrestricted diet at the end of the first year of treatment.

  18. Phase I study of continuous MKC-1 in patients with advanced or metastatic solid malignancies using the modified Time-to-Event Continual Reassessment Method (TITE-CRM) dose escalation design.

    Science.gov (United States)

    Tevaarwerk, Amye; Wilding, George; Eickhoff, Jens; Chappell, Rick; Sidor, Carolyn; Arnott, Jamie; Bailey, Howard; Schelman, William; Liu, Glenn

    2012-06-01

    MKC-1 is an oral cell-cycle inhibitor with broad antitumor activity in preclinical models. Clinical studies demonstrated modest antitumor activity using intermittent dosing schedule, however additional preclinical data suggested continuous dosing could be efficacious with additional effects against the mTor/AKT pathway. The primary objectives were to determine the maximum tolerated dose (MTD) and response of continuous MKC-1. Secondary objectives included characterizing the dose limiting toxicities (DLTs) and pharmacokinetics (PK). Patients with solid malignancies were eligible, if they had measurable disease, ECOG PS ≤1, and adequate organ function. Exclusions included brain metastases and inability to receive oral drug. MKC-1 was dosed twice daily, continuously in 28-day cycles. Other medications were eliminated if there were possible drug interactions. Doses were assigned using a TITE-CRM algorithm following enrollment of the first 3 pts. Disease response was assessed every 8 weeks. Between 5/08-9/09, 24 patients enrolled (15 M/9 F, median 58 years, range 44-77). Patients 1-3 received 120 mg/d of MKC-1; patients 4-24 were dosed per the TITE-CRM algorithm: 150 mg [n = 1], 180 [2], 200 [1], 230 [1], 260 [5], 290 [6], 320 [5]. The median time on drug was 8 weeks (range 4-28). The only DLT occurred at 320 mg (grade 3 fatigue). Stable disease occurred at 150 mg/d (28 weeks; RCC) and 320 mg/d (16 weeks; breast, parotid). Escalation halted at 320 mg/d. Day 28 pharmacokinetics indicated absorption and active metabolites. Continuous MKC-1 was well-tolerated; there were no RECIST responses, although clinical benefit occurred in 3/24 pts. Dose escalation stopped at 320 mg/d, and this is the MTD as defined by the CRM dose escalation algorithm; this cumulative dose/cycle exceeds that determined from intermittent dosing studies. A TITE-CRM allowed for rapid dose escalation and was able to account for late toxicities with continuous dosing via a modified algorithm.

  19. Integral dose and evaluation of irradiated tissue volume

    International Nuclear Information System (INIS)

    Sivachenko, T.P.; Kalina, V.K.; Belous, A.K.; Gaevskij, V.I.

    1984-01-01

    Two parameters having potentialities of radiotherapy planning improvement are under consideration. One of these two parameters in an integral dose. An efficiency of application of special tables for integral dose estimation is noted. These tables were developed by the Kiev Physician Improvement Institute and the Cybernetics Institute of the Ukrainian SSR Academy of Science. The meaning of the term of ''irradiated tissue volume'' is specified, and the method of calculation of the irradiated tissue effective mass is considered. It is possible to evaluate with higher accuracy tolerance doses taking into account the irradiated mass

  20. Maximum permissible concentration (MPC) values for spontaneously fissioning radionuclides

    International Nuclear Information System (INIS)

    Ford, M.R.; Snyder, W.S.; Dillman, L.T.; Watson, S.B.

    1976-01-01

    The radiation hazards involved in handling certain of the transuranic nuclides that exhibit spontaneous fission as a mode of decay were reaccessed using recent advances in dosimetry and metabolic modeling. Maximum permissible concentration (MPC) values in air and water for occupational exposure (168 hr/week) were calculated for 244 Pu, 246 Cm, 248 Cm, 250 Cf, 252 Cf, 254 Cf, /sup 254m/Es, 255 Es, 254 Fm, and 256 Fm. The half-lives, branching ratios, and principal modes of decay of the parent-daughter members down to a member that makes a negligible contribution to the dose are given, and all daughters that make a significant contribution to the dose to body organs following inhalation or ingestion are included in the calculations. Dose commitments for body organs are also given