WorldWideScience

Sample records for maxillary angled implants

  1. The single-tooth implant treatment of congenitally missing maxillary lateral incisors using angled abutments: A clinical report

    Directory of Open Access Journals (Sweden)

    Suleyman Hakan Tuna

    2009-01-01

    Full Text Available The maxillary lateral incisor is the second most common congenitally absent tooth. There are several treatment options for replacing the missing maxillary lateral incisor, including canine substitution, tooth-supported restoration, or single-tooth implant. Dental implants are an appropriate treatment option for replacing missing maxillary lateral incisor teeth in adolescents when their dental and skeletal development is complete. This case report presents the treatment of a patient with congenitally missing maxillary lateral incisors using dental implants with angled abutments.

  2. Implant angulation: 2-year retrospective analysis on the influence of dental implant angle insertion on marginal bone resorption in maxillary and mandibular osseous onlay grafts.

    Science.gov (United States)

    Ramaglia, Luca; Toti, Paolo; Sbordone, Carolina; Guidetti, Franco; Martuscelli, Ranieri; Sbordone, Ludovico

    2015-05-01

    The purpose of this study was to determine the existence of correlations between marginal peri-implant linear bone loss and the angulation of implants in maxillary and mandibular augmented areas over the course of a 2-year survey. Dependent variables described the sample of the present retrospective chart review. By using three-dimensional radiographs, input variables, describing the implant angulation (buccal-lingual angle [φ] and mesial-distal angle [θ]) were measured; outcome variables described survival rate and marginal bone resorption (MBR) around dental implants in autogenous grafts (10 maxillae and 14 mandibles). Pairwise comparisons and linear correlation coefficient were computed. The peri-implant MBR in maxillary buccal and palatal areas appeared less intensive in the presence of an increased angulation of an implant towards the palatal side. Minor MBR was recorded around mandibular dental implants positioned at a right angle and slightly angulated towards the mesial. Resorption in buccal areas may be less intensive as the angulation of placed implants increases towards the palatal area in the maxilla, whereas for the mandible, a greater inclination towards the lingual area could be negative. In the mandibular group, when the implant was slightly angulated in the direction of the distal area, bone resorption seemed to be more marked in the buccal area. In the planning of dental implant placement in reconstructed alveolar bone with autograft, the extremely unfavourable resorption at the buccal aspect should be considered; this marginal bone loss seemed to be very sensitive to the angulation of the dental implant.

  3. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  4. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient

  5. Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Tomita, Akiko; Mizuno, Yoko; Maeda, Yoshinobu

    2016-01-01

    As maxillary implant overdentures are being increasingly used in clinical practice, prosthodontic complications related to these dentures are also reported more often. The purpose of this study was to examine the influence of palatal coverage and implant distribution on the shear strain of maxillary implant overdentures. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar areas was fabricated. Two kinds of experimental overdentures, with and without palatal coverage, were also fabricated, and two strain gauges were attached at the midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain in each denture was compared by analysis of variance (P = .05). In all situations, the shear strain in palateless dentures was significantly higher than in dentures with palate on both sides (P overdentures exhibited much higher strain than overdentures with palate regardless of the implant distribution; this may cause more prosthodontic and implant complications. The most favorable configuration to prevent complications in maxillary implant overdentures was palatal coverage that was supported by more than four widely distributed implants.

  6. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  7. Progressive immediate loading of a perforated maxillary sinus dental implant: a case report

    Directory of Open Access Journals (Sweden)

    Al-Juboori MJ

    2015-01-01

    Full Text Available Mohammed Jasim Al-Juboori Department of Oral Surgery, MAHSA University, Kuala Lumpur, Malaysia Abstract: The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement. Keywords: progressive implant loading, resonance frequency analysis, implant stability, provisional crown, bone density, maxillary sinus

  8. Evaluation the success of osseointegrated implants in maxillary sinus grafts

    Directory of Open Access Journals (Sweden)

    Rubens Eduardo Gigli

    2008-01-01

    Full Text Available Objective: To analyze implants placed in maxillary sinus grafts with biomaterial of bovine origin and platelet-rich plasma, observing bone neoformation and the clinical and histologic success rate presented.Methods: Analysis of the clinical findings was based on 36 maxillary sinus grafts with 101 implants placed in 30 patients with a mean age of 47 years, and the histologic analysis, based on nine samples of the 36 grafts performed, with a mean interval of 7.5 months time of the graft, the majority of patients being men with a mean age of 42 years. Results: Clinically, 91 implants placed were osseointegrated.Conclusion: Based on the results presented, it was concluded that when implants are placed in the maxillary sinus region grafted with biomaterial, they present a high success rate. ISRCTN24003246

  9. Maxillary overdentures retained by splinted and unsplinted implants : A retrospective study

    NARCIS (Netherlands)

    Narhi, TO; Hevinga, M; Voorsmit, RACA; Kalk, W

    2001-01-01

    The purpose of this retrospective study was to evaluate the clinical performance of and patients' satisfaction with maxillary overdentures retained by splinted and unsplinted implants. Patients who had been treated with maxillary implant-retained overdentures because of functional problems with

  10. Maxillary implant-retained partial overdenture with Dolder bar attachment: a clinical report.

    Science.gov (United States)

    Kim, Hyeongil; Buhite, Robert J; Monaco, Edward A

    2015-03-01

    This article describes a technique for maintaining a maxillary Kennedy III partial removable dental prosthesis design in a patient who had non-restorable failing abutments by replacing the abutments with dental implants. Two implants were placed immediately after extraction of the abutment teeth in the anterior maxilla. After the implants were fully integrated, a Dolder bar attachment was fitted onto the implants. A new maxillary partial removable dental prosthesis was fabricated using the implants and the remaining natural teeth as abutments to restore function and esthetics. With the aid of dental implants, this Kennedy III maxillary removable dental prosthesis design could provide additional retention and support by promoting cross-arch stability and tissue, implant and tooth support. The patient's satisfaction was significantly increased.

  11. Effect of Attachment Type on Denture Strain in Maxillary Implant Overdentures: Part 1. Overdenture with Palate.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    This study examined the effects of attachments on strain in maxillary implant overdentures supported by two or four implants. A maxillary edentulous model with implants inserted into anterior, premolar, and molar areas was fabricated, and three types of unsplinted attachments-ball, locator, and magnet-were set on the implants distributed under various conditions. Maxillary experimental dentures were fabricated, and two strain gauges were attached at the anterior midline on the labial and palatal sides. A vertical occlusal load of 98 N was applied and shear strain of the dentures was measured. On both sides, magnet attachments resulted in the lowest shear strain, while ball attachments resulted in the highest shear strain under most conditions. However, differences in shear strain among the three attachment types were not significant when supported by four implants, especially molar implants. Shear strain of the maxillary implant overdenture was lowest when using magnet attachments. Magnet attachments mounted on four implants are recommended to prevent denture complications when using maxillary implant overdentures.

  12. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    Science.gov (United States)

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

    Science.gov (United States)

    Rutkunas, Vygandas; Mizutani, Hiroshi; Peciuliene, Vytaute; Bendinskaite, Ruta; Linkevicius, Tomas

    2008-01-01

    Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could potentially influence the outcomes. The articles from 1985 to 2007 related to the topic were identified in the online MEDLINE/Pubmed and other databases and manually. Primary articles were scanned, and irrelevant studies were excluded from the further review process. Potentially relevant titles and abstracts were provisionally included for consideration on the basis of full text articles. Full text articles were obtained from on-line and printed sources. The data from the studies were extracted and reviewed. The study has failed to identify any prospective satisfying inclusion/exclusion criteria RCT reporting on maxillary bone resorption. The number of maxillary complete denture relining incidences per patient was constantly increasing during the 10-year period. Maxillary complete denture remake incidences comprised 16-33 % of the number of patients followed during the 10-year period. Comparing patient satisfaction with upper dentures at the baseline and after two years, no decrease in satisfaction was noticed. There is no evidence that maxillary ridge resorption is accelerated with certain types of two-implant supported mandibular overdenture attachments. Most common complication for the maxilla - prosthetic maintenance. There is a risk of decreased patient satisfaction with bar-supported mandibular overdenture. Further studies are needed to provide evidence for the maxillary complete denture outcome with two-implant supported mandibular overdentures.

  14. The edentulous mandible opposing maxillary natural teeth: treatment considerations utilizing implant overdentures.

    Science.gov (United States)

    Winkler, S; Monasky, G E

    1993-01-01

    The restoration of the edentulous mandible opposing all or part of the maxillary natural dentition with implant overdentures is described. There are many situations in which the maxillary teeth opposing an edentulous mandible can and should be retained. Mandibular implant overdentures can be utilized as long as health considerations, morphologic features of the resorbed mandible, and maxillomandibular jaw relationships are satisfactory.

  15. Nasolabial and Interincisal Angle Evaluation in Anterior Maxillary Distraction Osteogenesis: A Case Study

    Directory of Open Access Journals (Sweden)

    Tojan Chacko Thekkekara

    2014-01-01

    Full Text Available Maxillary hypoplasia is a common developmental problem in cleft lip and palate deformities. These deformities have traditionally been corrected by means of orthognathic surgery. Management of skeletal deformities in the maxillofacial region has been a challenge for maxillofacial surgeons and orthodontists. Distraction osteogenesis (DO is a surgical technique that uses body′s own repairing mechanisms for optimal reconstruction of the hard and soft tissues. We present four cases of anterior maxillary distraction osteogenesis with tooth-borne distraction device— Hyrax, which were analyzed retrospectively using cephalometrics. Changes in nasolabial angle and interincisal angle after distraction of anterior maxillary segment were studied to conclude that there was no much change in the the nasolabial angle while the interincisal angle showed marked improvement.

  16. Removal of a Dental Implant Displaced into the Maxillary Sinus by Means of the Bone Lid Technique

    Directory of Open Access Journals (Sweden)

    Pietro Fusari

    2013-01-01

    Full Text Available Background. Rehabilitation of edentulous jaws with implant-supported prosthesis has become a common practice among oral surgeons in the last three decades. This therapy presents a very low incidence of complications. One of them is the displacement of dental implants into the maxillary sinus. Dental implants, such as any other foreign body into the maxillary sinus, should be removed in order to prevent sinusitis. Methods. In this paper, we report a case of dental implant migrated in the maxillary sinus and removed by means of the bone lid technique. Results and Conclusion. The migration of dental implants into the maxillary sinus is rarely reported. Migrated implants should be considered for removal in order to prevent possible sinusal diseases. The implant has been removed without any complications, confirming the bone lid technique to be safe and reliable.

  17. Maxillary implant-supported overdentures opposed by (partial) natural dentitions : A 5-year prospective case series study

    NARCIS (Netherlands)

    Boven, G. C.; Slot, J. W. A.; Raghoebar, G. M.; Vissink, A.; Meijer, H. J. A.

    2017-01-01

    The aim of this study was to assess the 5-year treatment outcome of maxillary implant-retained overdentures opposed by natural antagonistic teeth. Fifty consecutive patients received maxillary overdentures supported by six dental implants. Implants were placed in the anterior region, if enough bone

  18. The influence of erupting lateral teeth on maxillary anterior crowding in two Angle Class I maloclussion cases with high and low angles

    Directory of Open Access Journals (Sweden)

    Hiroshi Ueda

    2016-01-01

    Full Text Available Two cases of anterior crowding, both Skeletal Class I and Angle Class I maloclussion, one being low angle and the other high angle respectively, respectively, were treated and evaluated to ascertain whether or not there is a relationship among disproportionate mesial axial angulation of the maxillary lateral teeth and the Frankfurt Horizontal-Functional Occlusal plane, therefore generating maxillary anterior crowding. Both cases were Japanese boys, the first one aged 9 years 10 months with chief complaint being anterior crowding and the second case aged 7 years and 8 months complaining of inadequate space for satisfying canine eruption. During and after the second stage of orthodontic treatment on both cases, several radiographic analysis were performed to assess treatment progress and retention; from these radiographs, it was noticed among other findings that in the high-angle case, the axial angulations of the maxillary lateral incisors were markedly smaller than in the low-angle case, thus indicating mesial tipping in the upper dental arch. This decreased mesial axial angulation of the lateral teeth observed at high angles may potentially cause maxillary space deficiency.

  19. Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 1. Overdenture with Palate.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Implant overdentures with attachments have been used in clinical practice and the effect of attachments on implant strain has been frequently reported. However, most studies have focused on mandibular overdentures; there are few reports on maxillary overdentures. The purpose of this study was to examine the influence of attachment type on implant strain in maxillary overdentures under various implant configurations. A maxillary edentulous model with implants and experimental overdentures were fabricated. Four strain gauges were attached to each implant, positioned in anterior, premolar, and molar areas. Three types of unsplinted attachments-ball, locator, and magnet-were set on the implants under various implant configurations. A vertical occlusal load of 98 N was applied through the mandibular complete denture, and implant strain was compared using the Kruskal-Wallis test. Ball attachments caused the greatest amount of strain, while magnet attachments caused the least amount under all conditions. For all attachments, two anterior implants caused significantly more strain than four implants (P magnet attachments are recommended to reduce implant stress. Using only two implants, especially two anterior implants, is not recommended regardless of attachment type.

  20. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  1. Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Surgical Outcomes of a Randomized Controlled Trial.

    Science.gov (United States)

    Ma, Sunyoung; Tawse-Smith, Andrew; De Silva, Rohana K; Atieh, Momen A; Alsabeeha, Nabeel H M; Payne, Alan G T

    2016-06-01

    The surgical placement of four maxillary implants for overdentures may not be obligatory when opposing mandibular two-implant overdentures. To determine 10-year surgical outcomes and implant success of three narrow diameter implants in edentulous maxillae with conventional loading. Forty participants with mandibular two-implant overdentures were randomly allocated for surgery for maxillary overdentures. Using osteotomes, three implants of similar systems were placed with a one-stage procedure and 12-week loading with splinted and unsplinted prosthodontic designs. Marginal bone and stability measurements were done at surgery, 12 weeks, 1-, 2-, 5-, 7-, 10 years. One hundred seventeen implants were placed in 39 participants, with 35 being seen at 1 year; 29 at 2 years; 28 at 5 years; 26 at 7 years; and 23 (59%) at 10 years. Marginal bone loss was 1.35 mm between surgery and 12 weeks; 0.36 mm between 12 weeks and 1 year; 0.48 mm between 1 and 5 years; and 0.22 mm between 5 and 10 years. Implant stability quotients were 56.05, 57.54, 60.88, 58.80, 61.17 at surgery, 12 weeks, 1 year, 5 years, and 10 years. Four-field tables by implant showed success rates of 82% at 1 year; 69.2% at 2 years; 66.7% at 5 years; 61.5% at 7 years; 51.3% at 10 years. Data showed no differences between surgical technique, systems, or prosthodontic designs. Surgical placement with osteotomes of three narrow diameter implants for maxillary overdentures, opposing mandibular two-implant overdentures, is an acceptable approach, subject to strict patient selection. Implant success is independent of prosthodontic design. © 2015 Wiley Periodicals, Inc.

  2. Maxillary sinus function after sinus lifts for the insertion of dental implants

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; Boering, G; VanWeissenbruch, R

    Purpose: The influence of bone augmentation of the floor of the maxillary sinus for the insertion of denial implants on sinus function has not been well investigated, In this study, the influence of the sinus lift on the development of maxillary sinus pathology was evaluated using generally accepted

  3. Success of Unsplinted Implant-Retained Removable Mandibular and Maxillary Overdentures: A Retrospective Study of Consecutive Cases.

    Science.gov (United States)

    Strong, Samuel M

    2015-01-01

    Implant-retained overdentures have been provided on both splinted and freestanding implants. For the mandible, a long history shows that both approaches can be successful over the long term. For the maxilla, many clinicians prefer to splint the implants because of concerns about softer bone quality and insufficient data supporting the use of freestanding overdenture abutments. However, a few investigations have found survival rates for unsplinted maxillary overdentures to be comparable to those for splinted ones. The present study analyzed records of consecutive patients who were treated with unsplinted maxillary and mandibular overdentures and followed for 4 to 107 months. A total of 31 overdentures were identified, 15 maxillary and 16 mandibular, supported by 129 implants. All the overdentures, along with all the implants, survived throughout the follow-up period.

  4. Maxillary "All-On-Four" treatment using zygomatic implants. A mechanical analysis.

    Science.gov (United States)

    de Moraes, P H; Olate, S; Nóbilo, M de Arruda; Asprino, L; de Moraes, M; Barbosa, J de Albergaría

    2016-04-01

    Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Maxillary Implant-Supported Fixed Prosthesis: A Survey of Reviews and Key Variables for Treatment Planning.

    Science.gov (United States)

    Gallucci, German O; Avrampou, Marianna; Taylor, James C; Elpers, Julie; Thalji, Ghadeer; Cooper, Lyndon F

    2016-01-01

    This review was conducted to provide information to support the establishment of clinical guidelines for the treatment of maxillary edentulism using implant-supported fixed dental prostheses. Initial efforts were directed toward a systematic review with a defined PICO question: "For maxillary edentulous patients with dental implants treated using a fixed prosthesis, what is the impact of prosthesis design on prosthesis survival and complications?" Following a title search of more than 3,000 titles identified by electronic search of PubMed, 180 articles were identified that addressed the clinical evaluation of maxillary dental implant prostheses. The broad methodologic heterogeneity and clinical variation among reports precluded this approach for a systematic review. The information was extracted using a standardized extraction table by two pairs of investigators, and the reported outcomes were then summarized according to reported outcomes for implant prostheses supported by four, six, or eight implants using unitary or segmented prostheses. This review indicated that high prosthetic survival is observed using all approaches. The advantages of using fewer implants and a unitary prosthesis are revealed in the surgical phases, and complications commonly involve the fracture or detachment of acrylic teeth and reduced access for proper oral hygiene and related biologic complications. Using six implants typically involved grafting of posterior regions with advantages of reduced cantilevers and redundancy of implant support. Reduced prosthesis survival in these cases was associated with poor implant distribution. Segmented prostheses supported by six or more implants offered greater prosthetic survival, perhaps due to posterior implant placement. Advantages of a segmented prosthesis included pragmatic issues of accommodating divergent implants, attaining passive fit, combining prosthetic materials, and relative simplicity of repair. The existing literature demonstrated

  6. Nonsurgical management of soft tissue around the restorations of maxillary anterior implants: a clinical report

    Directory of Open Access Journals (Sweden)

    Seyedan K

    2010-01-01

    Full Text Available "nBackground and Aims: Soft tissue management with providing the esthetic for restoration of a single implant in the anterior maxilla is of great importance. Tissue training helps to develop a proper emergence profile and natural tooth appearance. The aim of this article was to report a nonsurgical management of undesirable contours of soft tissue around maxillary anterior implants to achieve an optimum appearance. "nMaterials and Methods: A 23-year-old female with congenital missing of maxillary lateral incisors, after completion of a fixed orthodontic treatment and gain enough space, received 2 dental implants. After second phase surgery and healing period, construction of the restorations was not possible through conventional method because of severe soft tissue collapse. In this case, soft tissue contours were corrected using a provisional restoration and then final restoration was made and delivered. "nConclusion: Tissue training with a provisional restoration helps to re-establish normal gingival tissue contours and interdental papillae around the restoration of maxillary anterior implants.

  7. Attachment of clips in a bar-retained maxillary implant overdenture : a clinical report

    NARCIS (Netherlands)

    Slot, J.W.A.; Raghoebar, G.M.; Dijk, G. van; Meijer, H.J.A.

    Implant-supported overdentures are a good alternative for patients with conventional dentures that lack retention and stability. The most common prosthetic complications in mandibular and maxillary implant-supported overdentures are fracture and loosening of the attachment system. This clinical

  8. Maxillary Four Implant-retained Overdentures via Locator® Attachment: Intermediate-term Results from a Retrospective Study.

    Science.gov (United States)

    Wang, Feng; Monje, Alberto; Huang, Wei; Zhang, Zhiyong; Wang, Guomin; Wu, Yiqun

    2016-06-01

    Maxillary overdentures have been utilized to restore oral function in scenarios where limited bone structure represents a drawback for financial issues and for cases where oral hygiene is uncertain. The aim of this study was to evaluate the intermediate-term clinical outcome of four locator attachment retaining maxillary overdentures and to test their reliability. A retrospective study was conducted from January 2007 to October 2013. After the placement of four maxillary dental implants and a healing period of approximately 3 months, all the implants were restored with locator-retained overdentures with partial palatal coverage. Subjects and implant characteristics, implant position (anterior vs posterior maxilla), bone quality, and opposing dentition were recorded. Peri-implant clinical parameters and marginal bone loss (MBL) were evaluated after delivery of the final prosthesis and annually thereafter. The performance of locator components and the prosthetic restoration were also recorded at follow-up. A total of 104 implants were placed in 26 subjects (11 women, 15 men; mean age, 64 years; age range, 55-76 years). One implant failed before loading. One subject dropped out of the study during a mean follow-up period of 46 months (range: 7-73 months), achieving an overall survival rate of 95.2%. Clinical parameters revealed healthy tissues around most of the implants, with low scores of plaque and bleeding indices. At the last follow-up evaluation, the mean MBL was 1.7 ± 1.1 mm (0.4-2.6 mm). Regression model analysis indicated that MBL for implants in the posterior maxilla was significantly higher than that for implants in the anterior maxilla (p = .0487). Overall, 26 technical and prosthetic complications were reported. Within the limitations of this study, maxillary four implant-retained overdentures via Locator attachment seem to be a predictable alternative for oral rehabilitation. © 2015 Wiley Periodicals, Inc.

  9. Transverse maxillary and mandibular growth during and after bionator therapy: study with metallic implants.

    Science.gov (United States)

    Monini, André da Costa; Júnior, Luiz Gonzaga Gandini; Maia, Luiz Guilherme Martins; Pinto, Ary dos Santos

    2013-01-01

    This study evaluated posteroanterior cephalograms before and after treatment and long term follow-up of Class II division 1 patients treated with bionator. The objective was to demonstrate the transverse growth of maxilla and mandible during and after bionator therapy. Measurement of transverse dimensions between posterior maxillary and mandibular implants, as well as the distances between the buccal, gonial and antegonial points were recorded. Measurements were analyzed at three periods: T1 - before bionator therapy, T2 - after bionator therapy and T3 - 5.74 years after T2. There was statistically significant transverse increase due to growth and/or treatment for all variables, except for the distance between the anterior maxillary implants. During the study period only the anterior maxillary area did not show transverse growth.

  10. Maxillary Overdentures Supported by Four Splinted Direct Metal Laser Sintering Implants: A 3-Year Prospective Clinical Study

    Directory of Open Access Journals (Sweden)

    Francesco Mangano

    2014-01-01

    Full Text Available Purpose. Nowadays, the advancements in direct metal laser sintering (DMLS technology allow the fabrication of titanium dental implants. The aim of this study was to evaluate implant survival, complications, and peri-implant marginal bone loss of DMLS implants used to support bar-retained maxillary overdentures. Materials and Methods. Over a 2-year period, 120 implants were placed in the maxilla of 30 patients (18 males, 12 females to support bar-retained maxillary overdentures (ODs. Each OD was supported by 4 implants splinted by a rigid cobalt-chrome bar. At each annual follow-up session, clinical and radiographic parameters were assessed. The outcome measures were implant failure, biological and prosthetic complications, and peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact, DIB. Results. The 3-year implant survival rate was 97.4% (implant-based and 92.9% (patient-based. Three implants failed. The incidence of biological complication was 3.5% (implant-based and 7.1% (patient-based. The incidence of prosthetic complication was 17.8% (patient-based. No detrimental effects on marginal bone level were evidenced. Conclusions. The use of 4 DMLS titanium implants to support bar-retained maxillary ODs seems to represent a safe and successful procedure. Long-term clinical studies on a larger sample of patients are needed to confirm these results.

  11. Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study.

    Science.gov (United States)

    Mangano, Francesco; Luongo, Fabrizia; Shibli, Jamil Awad; Anil, Sukumaran; Mangano, Carlo

    2014-01-01

    Purpose. Nowadays, the advancements in direct metal laser sintering (DMLS) technology allow the fabrication of titanium dental implants. The aim of this study was to evaluate implant survival, complications, and peri-implant marginal bone loss of DMLS implants used to support bar-retained maxillary overdentures. Materials and Methods. Over a 2-year period, 120 implants were placed in the maxilla of 30 patients (18 males, 12 females) to support bar-retained maxillary overdentures (ODs). Each OD was supported by 4 implants splinted by a rigid cobalt-chrome bar. At each annual follow-up session, clinical and radiographic parameters were assessed. The outcome measures were implant failure, biological and prosthetic complications, and peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact, DIB). Results. The 3-year implant survival rate was 97.4% (implant-based) and 92.9% (patient-based). Three implants failed. The incidence of biological complication was 3.5% (implant-based) and 7.1% (patient-based). The incidence of prosthetic complication was 17.8% (patient-based). No detrimental effects on marginal bone level were evidenced. Conclusions. The use of 4 DMLS titanium implants to support bar-retained maxillary ODs seems to represent a safe and successful procedure. Long-term clinical studies on a larger sample of patients are needed to confirm these results.

  12. Managing the severely proclined maxillary anteriors by extracting traumatized right maxillary central incisor

    Directory of Open Access Journals (Sweden)

    Mahesh Jain

    2014-01-01

    Full Text Available A 14-year-old girl reported with severely proclined maxillary anterior teeth with fractured and discolored right maxillary central incisor with questionable prognosis. Autotransplantation of premolar to replace central incisor was considered a risky option as patient was 14-year-old with presence of advanced root development of premolar. The immediate placement of the prosthetic implant was also not possible because of patient′s age. Therefore, it was decided to use the space obtained by extracting questionable maxillary right central incisor for orthodontic purpose and also sacrificing the healthy premolar is invariably an excessive biological cost for a modest functional and aesthetic gain. Hence, the treatment plan for this case includes extraction of right maxillary central incisor and left maxillary first premolar, movement of right maxillary lateral incisor mesially, achieving normal axial inclination of maxillary anteriors with normal overjet and overbite. Mandibular arch was treated nonextraction due to congenitally missing central incisors with presence of normally inclined lower anteriors thereby maintaining Angles class I occlusion. Tipping, usually, seen in Begg mechanotherapy was used for our advantage to correct severely proclined maxillary anteriors with simultaneous bite opening mechanics. Case was completed in 19 months and posttreatment records including photographs, radiographs and study models were made. Begg wrap around the retainer was placed in the maxillary arch allowing natural settling of occlusion.

  13. Influence of reinforcement on strains within maxillary implant overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    2015-01-01

    The purpose of this study was to examine the influence of reinforcement of an embedded cast on the strains within maxillary implant overdentures. A maxillary edentulous model with implants placed bilaterally in the canine positions, dome-shaped copings, and experimental overdentures was fabricated. Rosette-type strain gauges were attached in the canine positions and at three points along the midline of the polished surface of the denture and connected to the sensor interface controlled by a personal computer. Experimental dentures with five different reinforcements were tested: without reinforcement; with a cast cobalt-chrome reinforcement over the residual ridge and the tops of the copings; with the same reinforcement from first molar to first molar, over the residual ridge and the tops of the copings; with the same reinforcement over the residual ridge and the sides of the copings; and with the same reinforcement from first molar to first molar, over the residual ridge and the sides of the copings. A vertical occlusal load of 49 N was applied to the first premolar and then to the first molar, and the strains were measured and compared by analysis of variance. In both loading situations, significantly less strain was recorded in dentures with reinforcement than in those without reinforcement. When the first premolar was loaded on dentures with and without palatal reinforcement at the first premolars, the strains on the denture with reinforcement over the tops of the copings were significantly lower than on the denture with reinforcement over the sides of the copings at the canine position. Cast reinforcement over the residual ridge and the top of copings embedded in an acrylic base reduced the strain from occlusal stress on maxillary implant overdentures.

  14. Transverse maxillary and mandibular growth during and after Bionator therapy: study with metallic implants

    Directory of Open Access Journals (Sweden)

    André da Costa Monini

    2013-06-01

    Full Text Available INTRODUCTION: This study evaluated posteroanterior cephalograms before and after treatment and long term follow-up of Class II division 1 patients treated with bionator. OBJECTIVE: The objective was to demonstrate the transverse growth of maxilla and mandible during and after bionator therapy. METHODS: Measurement of transverse dimensions between posterior maxillary and mandibular implants, as well as the distances between the buccal, gonial and antegonial points were recorded. Measurements were analyzed at three periods: T1 = before bionator therapy, T2 = after bionator therapy and T3 = 5.74 years after T2. RESULTS: There was statistically significant transverse increase due to growth and/or treatment for all variables, except for the distance between the anterior maxillary implants. CONCLUSIONS: During the study period only the anterior maxillary area did not show transverse growth.

  15. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  16. Maxillary overdentures supported by four or six implants in the anterior region: 5-year results from a randomized controlled trial.

    Science.gov (United States)

    Slot, Wim; Raghoebar, Gerry M; Cune, Marco S; Vissink, Arjan; Meijer, Henny J A

    2016-12-01

    To compare a four- and six-implant maxillary overdenture after an observation period of 5 years. Fifty subjects with functional problems concerning their maxillary denture, who had ample bone volume in the anterior region to place four or six implants, were included and randomly assigned to either group. Implant and overdenture survival, clinical performance, marginal bone loss and patient satisfaction were assessed. Forty-six patients completed the 5-year follow-up. One implant failed in the six implants group (99.2% survival) and none in the four implants group (100% survival). No overdentures had to be replaced during the observation period and the number of complications was limited. Clinical function was good, with no difference in clinical parameters between the groups. Mean marginal bone resorption was 0.50 ± 0.37 and 0.52 ± 0.43 mm in the four and six implant group respectively. In patients with functional complaints of their maxillary denture, bar-supported overdentures on four implants in the anterior maxillary region were not inferior to overdentures supported by six implants after 5 years of function. Implant survival and patient satisfaction were high, clinical parameters favourable, bone loss and complications to the denture were minor in both groups (Clinical trial registration number: NTR2969). © 2016 The Authors. Journal of Clinical Periodontology Published by John Wiley & Sons Ltd.

  17. Titanium versus zirconia implants supporting maxillary overdentures: three-dimensional finite element analysis.

    Science.gov (United States)

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    The purpose of this study was to compare the stress and strain occurring in peri-implant bone and implants used to support maxillary overdentures. Three-dimensional finite element analysis (3D FEA) was used to compare one-piece zirconia and titanium implants. Two types of implants were simulated using a 3D FEA model: one-piece zirconia and titanium implants (diameter, 3.8 × 11.5 mm) with 2.25-mm diameter ball abutments. In each simulation four implants were placed bilaterally in the canine/premolar region of an edentulous maxillary model. Static loads were applied axially and 20 degrees buccolingually on the buccal slope of the lingual cusps of posterior teeth of the first quadrant. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated. Comparable stress and strain values were shown in the peri-implant bone for both types of implants. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. Under oblique loading, maximum von Mises stresses and equivalent strain were more evident at the neck of the most distal implant on the loaded side. Under axial load, the stress and strain were transferred to the peri-implant bone around the apex of the implant. Maximum tensile stresses that developed for either material were well below their fracture strength. The highest stresses were mainly located at the distobuccal region of the neck for the two implant materials under both loading conditions. From a biomechanical point of view, ceramic implants made from yttrium-stabilized tetragonal polycrystalline zirconia may be a potential alternative to conventional titanium implants for the support of overdentures. This is particularly relevant for a select group of patients with a proven allergy to titanium. Prospective clinical studies are still required to confirm these in vitro results. Different simulations presenting various cortical bone

  18. [Comparing the anchorage effects of micro-implant and J hook on treating patients with maxillary protrusion].

    Science.gov (United States)

    Wu, Xin; Liu, Guo-yuan; Jiang, Yong-lian

    2015-10-01

    To investigate the differences in anchorage effects between micro-implants and J hook in treating patients with Class II division 1 maxillary protrusion. Thirty-one cases of adult patients with Class II division 1 maxillary protrusion were treated. They were divided into 2 groups depending on their selection. The first group included 17 patients for micro-implant anchorage, who adopted micro-implant and sliding mechanism to close maxillary extraction space and depress the mandibular molar. The second group encompassed 14 cases for J hook, who adopted sliding mechanism, J hooks in high traction and Class II intermaxillary traction to close extraction space. X-ray lateral cephalometric radiographs were measured before and after treatment, and SPSS16.0 software package was employed to compare the differences in soft and hard tissue changes before and after treatment between 2 groups. There were statistically significant differences in SNB, ANB, MP-FH, U1-Y, U6-Y, L6-MP, NLA, and UL-Y between the 2 groups before and after treatment, while there was no significant difference in SNA, U1-SN, U1-X, and U6-X between the 2 groups. In treating patients with Class II division 1 maxillary protrusion, micro-implant has stronger anchorage effects than J hook, while at the same time depressing the mandibular molars, and making it more favorable to improve Class II faces.

  19. A study on the variation of maxillary sinus volume and projection angle in children for CT scan

    International Nuclear Information System (INIS)

    Ji, Youn Sang; Dong, Kyung Rae; Choi, Seong Kwan; Kim, Mi Hyun; Jung, Myung Jin; Yeo, Hwa Yeon

    2017-01-01

    The Water's view is that you can examine and diagnose disease of the maxillary sinus and implemented a simple and economical because a lot of tests. Because changes in the size of the maxillary sinus and skull growth in volume, depending on the disease that occurs in children often differ from the baseline angle of the water's view that it is easy to observe. Through Computed tomography (CT) and volumetric analysis and Orbitmeatal line (OML) and Image plate (IP) is the angle and evaluate the appropriate Water's view angle in children

  20. Two-dimensional real-time blood flow and temperature of soft tissue around maxillary anterior implants.

    Science.gov (United States)

    Nakamoto, Tetsuji; Kanao, Masato; Kondo, Yusuke; Kajiwara, Norihiro; Masaki, Chihiro; Takahashi, Tetsu; Hosokawa, Ryuji

    2012-12-01

    The aims of this study were to (1) evaluate the basic nature of soft tissue surrounding maxillary anterior implants by simultaneous measurements of blood flow and surface temperature and (2) analyze differences with and without bone grafting associated with implant placement to try to detect the signs of surface morphology change. Twenty maxillary anterior implant patients, 10 bone grafting and 10 graftless, were involved in this clinical trial. Soft tissue around the implant was evaluated with 2-dimensional laser speckle imaging and a thermograph. Blood flow was significantly lower in attached gingiva surrounding implants in graftless patients (P = 0.0468). On the other hand, it was significantly lower in dental papillae (P = 0.0254), free gingiva (P = 0.0198), and attached gingiva (P = 0.00805) in bone graft patients. Temperature was significantly higher in free gingiva (P = 0.00819) and attached gingiva (P = 0.00593) in graftless patients, whereas it was significantly higher in dental papilla and free gingiva in implants with bone grafting. The results suggest that simultaneous measurements of soft-tissue blood flow and temperature is a useful technique to evaluate the microcirculation of soft tissue surrounding implants.

  1. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    Science.gov (United States)

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  2. Within-Subject Comparison of Maxillary Implant-Supported Overdentures with and without Palatal Coverage.

    Science.gov (United States)

    Zembic, Anja; Tahmaseb, Ali; Wismeijer, Daniel

    2015-06-01

    The purpose of this study was to compare patient-reported outcomes for maxillary implant-supported overdentures with and without palatal coverage. Twenty-one maxillary edentulous patients (six women, 15 men) were included. In total, 42 implants were inserted in the anterior maxilla. All patients received implant-supported overdentures on two retentive anchors with palatal coverage for 2 months. Thereafter, patient satisfaction was assessed by means of questionnaires capturing the oral health impact profile (OHIP) on functional limitation, physical pain, psychological discomfort, physical, psychological and social disability, and handicap. Additionally, cleaning ability, general satisfaction, speech, comfort, esthetics, stability, and chewing ability were rated. Subsequently, palatal coverage was reduced, and the patients wore the overdentures for another 2 months. Patient satisfaction was obtained in the same way as above, and the evaluated parameters were compared for the two overdenture designs. There were no significant differences between implant-supported overdentures with and without palatal coverage for any of the OHIP domains. The evaluation of additional parameters revealed significantly higher patient satisfaction for esthetics (mean difference 8.8 mm ± 24.6) and taste (mean difference 28.4 mm ± 29.9) without palatal coverage, p overdentures supported by two implants were equally satisfactory with and without palatal coverage. © 2013 Wiley Periodicals, Inc.

  3. The efficacy of maxillary protraction protocols with the micro-implant-assisted rapid palatal expander (MARPE) and the novel N2 mini-implant-a finite element study.

    Science.gov (United States)

    Moon, Won; Wu, Kimberley W; MacGinnis, Matthew; Sung, Jay; Chu, Howard; Youssef, George; Machado, Andre

    2015-01-01

    Maxillary protraction with the novel N2 mini-implant- and micro-implant-assisted rapid palatal expander (MARPE) can potentially provide significant skeletal effects without surgery, even in older patients where conventional facemask therapy has limited skeletal effects. However, the skeletal effects of altering the location and direction of force from mini-implant-assisted maxillary protraction have not been extensively analyzed. In this study, the application of the novel N2 mini-implant as an orthopedic anchorage device is explored in its ability to treat patients with class III malocclusions. A 3D cranial mesh model with associated sutures was developed from CT images and Mimics modeling software. Utilizing ANSYS simulation software, protraction forces were applied at different locations and directions to simulate conventional facemask therapy and seven maxillary protraction protocols utilizing the novel N2 mini-implant. Stress distribution and displacement were analyzed. Video animations and superimpositions were created. By changing the vector of force and location of N2 mini-implant, the maxilla was displaced differentially. Varying degrees of forward, downward, and rotational movements were observed in each case. For brachyfacial patients, anterior micro-implant-supported protraction at -45° or intermaxillary class III elastics at -45° are recommended. For dolicofacial patients, either anterior micro-implants at -15° or an intermaxillary spring at +30° is recommended. For mesofacial patients with favorable vertical maxillary position, palatal micro-implants at -30° are recommended; anterior micro-implants at -30° are preferred for shallow bites. For patients with a severe mid-facial deficiency, intermaxillary class III elastics at -30° are most effective in promoting anterior growth of the maxilla. By varying the location of N2 mini-implants and vector of class III mechanics, clinicians can differentially alter the magnitude of forward, downward, and

  4. A study on the variation of maxillary sinus volume and projection angle in children for CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Youn Sang; Dong, Kyung Rae; Choi, Seong Kwan; Kim, Mi Hyun [Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Jung, Myung Jin [Dept. of Radiation Science and Technology, Graduate School of Chonbuk National University, Jeonju (Korea, Republic of); Yeo, Hwa Yeon [Dept. of Radiology, Nambu University, Gwangju (Korea, Republic of)

    2017-06-15

    The Water's view is that you can examine and diagnose disease of the maxillary sinus and implemented a simple and economical because a lot of tests. Because changes in the size of the maxillary sinus and skull growth in volume, depending on the disease that occurs in children often differ from the baseline angle of the water's view that it is easy to observe. Through Computed tomography (CT) and volumetric analysis and Orbitmeatal line (OML) and Image plate (IP) is the angle and evaluate the appropriate Water's view angle in children.

  5. Influence of implant position on clinical crown length and peri-implant soft tissue dimensions at implant-supported single crowns replacing maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2013-01-01

    The aims of the present study were to evaluate the influence of implant position on clinical crown length and marginal soft tissue dimensions at implant-supported single crowns of maxillary central incisors, and to validate the papilla index score (PIS). Twenty-five patients, who had lost one of ...... abutments and did not necessarily result in an increased crown length. The distal implant papilla heightwas obviously shorter, althoughthe mesial papilla height was similar to thatof the healthy dentition.The papilla index score was tested to be a valid index for papilla fill....

  6. Spiral Computed Tomography Based Maxillary Sinus Imaging in Relation to Tooth Loss, Implant Placement and Potential Grafting Procedure

    Directory of Open Access Journals (Sweden)

    Reinhilde Jacobs

    2010-01-01

    Full Text Available Objectives: The purpose of the present study was to explore the maxillary sinus anatomy, its variations and volume in patients with a need for maxillary implant placement.Materials and Methods: Maxillary sinus data of 101 consecutive patients who underwent spiral computed tomography (CT scans for preoperative implant planning in the maxilla at the Department of Periodontology, University Hospital, Catholic University of Leuven, Leuven, Belgium were retrospectively evaluated. The alveolar bone height was measured on serial cross-sectional images between alveolar crest and sinus floor, parallel to the tooth axis. In order to describe the size of the maxillary sinus anteroposterior (AP and mediolateral (ML diameters of the sinus were measured.Results: The results indicated that the alveolar bone height was significantly higher in the premolar regions in comparison to the molar region (n = 46, P 4 mm mucosal thickening mostly at the level of the sinus floor. The present sample did not allow revealing any significant difference (P > 0.05 in maxillary sinus dimensions for partially dentate and edentulous subjects.Conclusions: Cross-sectional imaging can be used in order to obtain more accurate information on the morphology, variation, and the amount of maxillary bone adjacent to the maxillary sinus.

  7. Maxillary Sinus Membrane Elevation With Simultaneous Installation of Implants Without the Use of a Graft Material

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Schou, Søren

    2017-01-01

    OBJECTIVE: To compare implant treatment outcome after maxillary sinus membrane elevation with simultaneous installation of implants with or without the use of graft material applying the lateral window technique. MATERIALS AND METHODS: MEDLINE/PubMed, Cochrane Library, and Embase search in combin...

  8. Maxillary implant-supported overdentures opposed by (partial) natural dentitions: a 5-year prospective case series study.

    Science.gov (United States)

    Boven, G C; Slot, J W A; Raghoebar, G M; Vissink, A; Meijer, H J A

    2017-12-01

    The aim of this study was to assess the 5-year treatment outcome of maxillary implant-retained overdentures opposed by natural antagonistic teeth. Fifty consecutive patients received maxillary overdentures supported by six dental implants. Implants were placed in the anterior region, if enough bone was present (n = 25 patients) Implant were placed in the posterior region if implant placement in the anterior region was not possible (n = 25 patients). Variables assessed included survival of implants, condition of hard and soft peri-implant tissues and patients' satisfaction. The five-year implant survival rate was 97·0% and 99·3%, and mean radiographic bone loss was 0·23 and 0·69 mm in the anterior and posterior group, respectively. Median scores for plaque, calculus, gingiva, bleeding and mean scores for pocket probing depth were low and stayed low. Patients' satisfaction after treatment was high in both groups. Within the limits of this 5-year study, it is concluded that six dental implants (placed in the anterior or posterior region) connected with a bar and opposed to natural antagonistic teeth result in acceptable results for clinical parameters and good outcomes for marginal bone level changes and patient satisfaction. © 2017 John Wiley & Sons Ltd.

  9. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    Science.gov (United States)

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  10. [Three dimensional finite element analysis of maxillary anterior teeth retraction with micro-implant anchorage and sliding mechanics].

    Science.gov (United States)

    Zhang, Yi; Zhang, Lei; Fan, Yu-bo; Song, Jin-lin; Deng, Feng

    2009-10-01

    To investigate the biomechanical effects of micro-implant anchorage technique with sliding mechanics on maxillary anterior teeth retraction under different implant insertion heights and different retraction hook heights. The three dimensional finite element model of maxillary anterior teeth retraction force system was constructed with CT scanning and MIMICS software and the relationships between brackets, teeth, wire and micro-implant were simulating the clinical factions. Then the initial tooth displacement was calculated when the insertion heights were 4 mm and 8 mm and the retraction hook heights were 1, 4, 7, 10 mm respectively. With retraction hook height added, the anterior teeth movement changed from lingual crown tipping to labial crown tipping and the intrusion movement was more apparent when the micro-implant was inserted in a higher location. The ideal teeth movement control could be achieved by different insertion heights of micro-implant and different retraction hook heights in straight wire retraction force system.

  11. Comparison of marginal bone loss and implant success between axial and tilted implants in maxillary All-on-4 treatment concept rehabilitations after 5 years of follow-up.

    Science.gov (United States)

    Hopp, Milena; de Araújo Nobre, Miguel; Maló, Paulo

    2017-10-01

    There is need for more scientific and clinical information on longer-term outcomes of tilted implants compared to implants inserted in an axial position. Comparison of marginal bone loss and implant success after a 5-year follow-up between axial and tilted implants inserted for full-arch maxillary rehabilitation. The retrospective clinical study included 891 patients with 3564 maxillary implants rehabilitated according to the All-on-4 treatment concept. The follow-up time was 5 years. Linear mixed-effect models were performed to analyze the influence of implant orientation (axial/tilted) on marginal bone loss and binary logistic regression to assess the effect of patient characteristics on occurrence of marginal bone loss >2.8 mm. Only those patients with measurements of at least one axial and one tilted implant available were analyzed. This resulted in a data set of 2379 implants (1201 axial, 1178 tilted) in 626 patients (=reduced data set). Axial and tilted implants showed comparable mean marginal bone losses of 1.14 ± 0.71 and 1.19 ± 0.82 mm, respectively. Mixed model analysis indicated that marginal bone loss levels at 5 years follow up was not significantly affected by the orientation (axial/tilted) of the implants in the maxillary bone. Smoking and female gender were associated with marginal bone loss >2.8 mm in a logistic regression analysis. Five-year implant success rates were 96%. The occurrence of implant failure showed to be statistically independent from orientation. Within the limitations of this study and considering a follow-up time of 5 years, it can be concluded that tilted implants behave similarly with regards to marginal bone loss and implant success in comparison to axial implants in full-arch rehabilitation of the maxilla. Longer-term outcomes (10 years +) are needed to verify this result. © 2017 Wiley Periodicals, Inc.

  12. Apical root resorption in maxillary incisors when employing micro-implant and J-hook headgear anchorage: a 4-month radiographic study.

    Science.gov (United States)

    Wang, Qingzhu; Chen, Wenjing; Smales, Roger J; Peng, Hui; Hu, Xiaokun; Yin, Lu

    2012-10-01

    This study evaluated, over a 4-month study period, the amount of apical root resorption occurring in maxillary central incisors following their retraction when employing either micro-implant or J-hook headgear anchorage. The prospective randomised clinical trial was conducted in Orthodontic Clinic, College of Stomatology, China from 2008-2009. Subjects are patients requiring fixed appliances on waiting list (n=20). In female Han Chinese patients aged from 16-26 years, standardized periapical radiographs from 10 randomly assigned patients with maxillary protrusions comprising the micro-implant group, and from 10 similar patients comprising the J-hook headgear group, were assessed for maxillary central incisor apical root resorption. Measurements before and after orthodontic therapy were also obtained from lateral cephalometric radiographs to calculate incisor horizontal retraction and vertical intrusion distances. Estimated retraction force vectors were calculated in horizontal and vertical directions for both treatment groups. Data analysis employed t-tests and the Pearson correlation test, with α=0.05 for statistical significance. The results showed that when compared with the J-hook group, significantly more apical root resorption shortening of the maxillary central incisors was observed in the micro-implant group (1.27 mm difference, 95% CI=0.70-1.84, Pmicro-implant group resulted in significantly more apical root resorption shortening and maxillary central incisor retraction than when intermittent J-hook retraction was employed. The employment of continuous duration orthodontic forces presents a risk for increased apical root resorption that requires careful radiographic monitoring.

  13. Immediate loading and customized restoration of a single implant in the maxillary esthetic zone : A clinical report

    NARCIS (Netherlands)

    den Hartog, Laurens; Raghoebar, Gerry M.; Stellingsma, Kees; Meijer, Henny J. A.

    2009-01-01

    The replacement of a single missing anterior tooth with an implant-supported crown Is a demanding therapy. This report describes a treatment in which an anterior maxillary implant was immediately restored with a provisional restoration. During the provisional phase, an optimal emergence profile was

  14. Unsplinted implants and teeth supporting maxillary removable partial dentures retained by telescopic crowns: a retrospective study with >6 years of follow-up.

    Science.gov (United States)

    Frisch, Eberhard; Ratka-Krüger, Petra; Wenz, Hans-Jürgen

    2015-09-01

    Data regarding tooth- and implant-supported maxillary removable partial dentures (TIRPDs) are scarce. The objective of this research was to perform a retrospective evaluation of the clinical long-term outcome of maxillary TIRPDs rigidly retained via telescopic crowns in patients undergoing supportive post-implant therapy (SIT). The inclusion criteria were met by 26 patients restored with maxillary TIRPDs between 1997 and 2011 in a private practice. Primary crowns (Marburg double crowns, MDCs) on teeth were cemented, whereas those on implants were screw-retained. Using patient records and data from a cross-sectional clinical examination in 2013, the survival rates of the teeth, implants and prostheses, together with the biological and technical complications, were analyzed. After 6.12 ± 3.80 (range: 2-16) years of loading, 23 non-smoking patients with 23 dentures supported by 60 implants and 66 teeth were available for assessment. Nine teeth (survival rate: 86.36%) were lost, whereas 1 implant (survival rate: 98.36%) failed because of peri-implantitis. Although 30 implants (50%) in 16 patients (69.57%) showed bleeding on probing (BOP+), no further peri-implantitis was observed. The mean peri-implant probing depth (PPD) was 3.68 ± 0.71 mm. All dentures were functional and required technical maintenance efforts amounting to 0.128 treatments per patient per year (T/P/Y). Within the limitations of this study, we conclude that TIRPDs retained via MDCs may represent a viable treatment option for patients with residual maxillary teeth. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants with different surface textures

    DEFF Research Database (Denmark)

    Karlsson, U; Gotfredsen, K; Olsson, C

    1998-01-01

    In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1...

  16. Influence of Implant Number and Location on Strain Around an Implant Combined with Force Transferred to the Palate in Maxillary Overdentures.

    Science.gov (United States)

    Yang, Tsung-Chieh; Chen, Yi-Chen; Wang, Tong-Mei; Lin, Li-Deh

    This study evaluated the effect of implant number and location on strain around the implant and force transferred to the palate in maxillary implant overdentures (IODs), including two locators attached bilaterally in the canine region (IOD 2), four locators attached bilaterally in the canine and premolar regions (IOD 4CP), four locators attached bilaterally in the canine and molar regions (IOD 4CM), and six locators attached bilaterally in the canine, premolar, and molar regions (IOD 6). As the implant number increased, strain around the implant regions increased, whereas force transferred to the palate decreased under loading. However, the differences were small between IOD 4CM and IOD 6, suggesting identical biomechanical effectiveness.

  17. Correction of Malpositioned Implants through Periodontal Surgery and Prosthetic Rehabilitation Using Angled Abutment

    Directory of Open Access Journals (Sweden)

    Érica Dorigatti de Avila

    2014-01-01

    Full Text Available When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i abutment substitution to compensate the incorrect angulation of the implant, (ii clinical crown lengthening, (iii atraumatic extraction of the left central incisor, and (iv immediate implant placement. Finally, (v a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

  18. Evaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT

    International Nuclear Information System (INIS)

    Ishii, Takenobu; Nojima, Kunihiko; Nishii, Yasushi; Takaki, Takashi; Yamaguchi, Hideharu

    2004-01-01

    The interalveolar septum between the upper first molar and the second premolar of the separated human maxillary bone was three-dimensionally observed by micro CT to evaluate the appropriate mini-screw type implant placement position by considering the relationship between the tooth roots and the maxillary sinus. After taking micro CTs of 5 human maxillary bones, horizontally sectioned images of the interalveolar septum area 2, 4, 6, 8, 10, and 12 mm deep from the crest of the alveolar ridge were reconstructed by three-dimensional reconstruction software. The bucco-lingual and mesio-distal lengths and area in each sectioned interalveolar septum were measured using digital image measurement software. Using the results, the interalveolar septum area between the upper first molar and the second premolar approximately 6-8 mm deep from the alveolar crest in the tooth root apical direction was determined to be the safest position for mini-screw implantation. Furthermore, lateral implantation from the palatal side was deduced to be the safest approach. (author)

  19. Optimizing Maxillary Aesthetics of a Severe Compromised Tooth through Orthodontic Movement and Dental Implants

    Directory of Open Access Journals (Sweden)

    Rafael Scaf de Molon

    2014-01-01

    Full Text Available Treatment of severe compromised tooth in the maxillary anterior area still poses great challenge to the clinicians. Several treatment modalities have been proposed to restore the function and aesthetics in teeth with advanced periodontal disease. The present study aims to report a case of traumatic injury of a left-maxillary central incisor with ridge preservation, orthodontic movement, and implant therapy. A 45-year-old woman underwent the proposed treatment for her left central incisor: basic periodontal therapy, xenogenous bone graft, and guided bone regeneration (GBR. Six months after the graft procedure, orthodontic movement by means of alignment and leveling was made and a coronal displacement of the gingival margin and vertical bone apposition could be observed after 13 months of active movement. Afterwards, a dental implant was placed followed by a connective tissue graft and immediate provisionalization of the crown. In conclusion, orthodontic movement was effective to improve the gingival tissue and alveolar bone prior to implant placement favoring the aesthetic results. Six years postoperatively, the results revealed height and width alveolar bone gain indicating that the treatment proposed was able to restore all the functional and aesthetic parameters.

  20. Maxillary sinus augmentation

    Directory of Open Access Journals (Sweden)

    A B Tarun Kumar

    2015-01-01

    Full Text Available Placing dental implants in the maxillary posterior region can be both challenging and un-nerving for a regular implant dentist who is not well versed with advanced surgical procedures. It is vital for a general dentist to understand the fundamentals of bone grafting the maxillary sinus if he/she is really committed to providing the best health care for their patients. The dental practice is seeing an increasing group of patients who are living longer, and this group of older baby boomers often has an edentulous posterior maxilla either unilateral or bilateral. When edentulous, the posterior maxilla more likely has diminished bone height, which does not allow for the placement of dental implants without creating additional bone. Through grafting the maxillary sinus, bone of ideal quality can be created (allowing for placement of dental implants, which offer many advantages over other tooth replacement modalities. The sinus graft offers the dental patient a predictable procedure of regenerating lost osseous structure in the posterior maxilla. This offers the patient many advantages for long-term success. If dentists understand these concepts, they can better educate their patients and guide them to have the procedure performed. This article outlines bone grafting of the maxillary sinus for the purpose of placing dental implants. This review will help the readers to understand the intricacies of sinus augmentation. They can relate their patient's condition with the available literature and chalk out the best treatment plan for the patient, especially by using indirect sinus augmentation procedures which are less invasive and highly successful if done using prescribed technique.

  1. The influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge. A 5-year randomised clinical trial.

    Science.gov (United States)

    Elsyad, M A; Ashmawy, T M; Faramawy, A G

    2014-01-01

    This study aimed to compare the influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m ), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar-implant-retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments. © 2013 John Wiley & Sons Ltd.

  2. Use of the frontal process of the maxillary bone for implant placement to retain a nasal prosthesis: a clinical report.

    Science.gov (United States)

    Proussaefs, Periklis

    2004-01-01

    Implant placement to provide support and retention for nasal prostheses has been described in the literature. The anatomic sites that have been utilized for implant placement are the nasal bones, the premaxillary area through the nasal fossae, and the anterior wall of the frontal sinus. In the patient described, after a presurgical computerized tomography scan to determine adequacy of bone volume, 1 conventional threaded hydroxyapatite-coated root-form implant, created for intraoral use, was placed in the frontal process of the maxillary bone and 2 additional conventional implants were placed in the premaxillary area through the nasal fossa. Six months after implant placement, second-stage surgery was completed. A single bar connecting the 3 implants was fabricated. The removable nasal prosthesis was retained on the bar with 2 clips. An examination 1 year postsurgery revealed no clinical signs of pathosis. Long-term clinical follow-up of this case should continue and a sufficient number of additional cases should be investigated before use of the frontal process of the maxillary bone for implant retention can be recommended on a routine basis.

  3. Clinical follow-up of unilateral, fixed dental prosthesis on maxillary implants.

    Science.gov (United States)

    Wahlström, Monica; Sagulin, Gun-Britt; Jansson, Leif E

    2010-11-01

    The aims of the present study were to evaluate (1) the success rate of unilateral maxillary fixed dental prosthesis (FDPs) on implants in patients at a periodontal clinic referred for periodontal treatment, (2) the prevalence of varying mechanical and biological complications and (3) effects of potential risk factors on the success rate. Fifty consecutive patients were invited to participate in a follow-up. The patients had received FDPs on implants between November 2000 and December 2003 after treatment to achieve optimal peridontal health, and the FDPs had been in function for at least 3 years. A questionnaire was sent to the patients before the follow-up examination. Forty-six patients with 116 implants were examined. The follow-up comprised clinical and radiographic examinations and evaluations of treatment outcome. Before implant treatment, 13% of the teeth were extracted; of these, 80% were extracted due to periodontal disease. No implants had been lost before implant loading. One implant in one patient fractured after 3 years of functional loading and three implants in another patient after 6.5 years. The most frequent mechanical complications were veneer fractures and loose bridge screws. Patients with peri-implant mucositis had significantly more bleeding on probing around teeth and implants. Patients with peri-implantitis at the follow-up had more deep periodontal pockets around their remaining teeth compared with individuals without peri-implantitis, but these differences were not significant. Smokers had significantly fewer teeth, more periodontal pockets ≥ 4mm and a tendency towards greater marginal bone loss at the follow-up, compared with non-smokers. In the short term, overloading and bruxism seem more hazardous for implant treatment, compared with a history of periodontitis.

  4. Immediate implant placement and provisional crown fabrication after a minimally invasive extraction of a peg-shaped maxillary lateral incisor: a clinical report.

    Science.gov (United States)

    Turkyilmaz, Ilser; Suarez, Jose Carlos; Company, Andrea M

    2009-09-01

    The aim of this case report is to describe the replacement of a maxillary peg-shaped lateral incisor with the placement of an immediate implant and a provisional restoration following a minimally invasive extraction to preserve anterior esthetics. Extraction sites in the anterior maxilla can present restorative challenges with regard to esthetics. Resistance to wearing a temporary removable partial denture during healing makes immediate implant therapy an appealing alternative to patients. Implant placement into fresh extraction sockets using no flap elevation has recently become more popular due to some advantages including less bleeding, swelling, and the preservation of existing soft tissue contours. A 20-year-old woman with a peg-shaped maxillary left lateral incisor was treated using an implant placed into the fresh extraction socket using a flapless approach and immediate provisional crown fabrication. Flapless implant placement helps to preserve site morphology by protecting and supporting existing hard and soft tissues while minimizing surgical trauma to the adjacent tissues. Using a previously fabricated acrylic index, a provisional acrylic crown was fabricated on the adjusted temporary abutment and delivered to the patient the same day during the extraction visit. This report describes the diagnosis and treatment of an over-prepared peg-shaped maxillary left lateral incisor associated with multiple crown decementations. The tooth was extracted without flap elevation and an implant was inserted immediately using flapless surgery and placement of an immediate provisional single crown. Flapless implant insertion into fresh extraction sockets and placement of immediate provisional crowns in cases involving the maxillary anterior region represent a viable treatment option in appropriate clinical situations where esthetics are a high priority. The strategy preserves optimum gingival contours and papillary height may be a viable option compared to fixed partial

  5. Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series.

    Science.gov (United States)

    Moráguez, Osvaldo; Vailati, Francesca; Grütter, Linda; Sailer, Irena; Belser, Urs C

    2017-07-01

    (1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion. Ten patients (six women, four men), mean age 49.4 ± 12.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance level P four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Ribbon-wise customized lingual appliance and orthodontic anchor screw for the treatment of skeletal high-angle maxillary protrusion without bowing effect.

    Science.gov (United States)

    Inami, Toru; Ito, Goshi; Miyazawa, Ken; Tabuchi, Masako; Goto, Shigemi

    2018-05-02

    This case report demonstrates the treatment of a skeletal Class II high-angle adult patient with bimaxillary protrusion, angle Class I occlusion, and crowded anterior teeth. A ribbon-wise arch wire and a customized lingual appliance with anterior vertical slots were used to achieve proper torque control of the maxillary anterior teeth. An orthodontic anchor screw and a palatal bar were used for vertical control to avoid increasing the Frankfort-mandibular plane angle (FMA) by maxillary molar extrusion. Through the combined use of the ribbon-wise customized lingual appliance, palatal bar, and orthodontic anchor screw, vertical control and an excellent treatment result were achieved without the vertical and horizontal bowing effects peculiar to conventional lingual treatment.

  7. Maxillary overdentures supported by anteriorly or posteriorly placed implants opposed by a natural dentition in the mandible: a 1-year prospective case series study.

    Science.gov (United States)

    Slot, Wim; Raghoebar, Gerry M; Vissink, Arjan; Meijer, Henny J A

    2014-02-01

    For maxillary overdenture therapy, treatment guidelines are missing. There is a need for longitudinal studies. The purpose of this 1-year prospective case series study was to assess the treatment outcome of maxillary overdentures supported by six dental implants opposed by natural antagonistic teeth in the mandible. Fifty patients were treated with a maxillary overdenture supported by six dental implants, either placed in the anterior region (n = 25 patients) or in the posterior region (n = 25 patients). Items of evaluation were the following: survival of implants, condition of hard and soft peri-implant tissues, and patients' satisfaction. One-year implant survival rate was 98% in the anterior group and 99.3% in the posterior group. Mean radiographic bone loss in the anterior and posterior groups after 1 year of loading was 0.22 and 0.50 mm, respectively. Mean scores for plaque, calculus, gingiva, bleeding, and pocket probing depth were low, and patients' satisfaction was high, with no differences between the groups. Six dental implants placed in either the anterior region or the posterior region of the edentulous maxilla, connected with a bar, and opposed by antagonistic teeth in the mandible supply a proper base for the support of an overdenture. © 2012 Wiley Periodicals, Inc.

  8. Retrospective radiographic study of marginal bone changes of 88 implants placed with split crest technique in the maxillary latero-posterior area

    Directory of Open Access Journals (Sweden)

    S. Longoni

    2016-04-01

    Full Text Available Aim This article presents a retrospective study on the behavior of implants placed with split crest technique in lateroposterior maxillary class IV atrophy. Materials and Methods Subjects who underwent implant placement following split crest technique in the maxillary latero-posterior area were enrolled in the present retrospective study. After a mean period of 6.2 years of function implant survival and success rates were assessed. Moreover, radiographic examination was made on digital periapical radiographs and by means of a specific software. Bone level changes were measured as the difference between the peri-implants crestal bone level and the implants shoulder during the last patient’s visit recall examination. Results A total of 30 patients satisfied the inclusion criteria and were included in the study; the subjects were treated with 88 implants (64 transmucosal and 24 submerged. The observation period for all patients treated with split crest technique varied between 4 and 8 years (mean 6.2 years. The implants survival rate was 96.6% and the prostheses survival rate was 100%. Bone resorption ranged between 2.3 mm and 2.7 mm. Conclusion Implants inserted in conjunction with split crest technique seems to be a promising therapy with similar results as conventional implant surgery.

  9. Esthetic outcome for maxillary anterior single implants assessed by different dental specialists.

    Science.gov (United States)

    Al-Dosari, Abdullah; Al-Rowis, Ra'ed; Moslem, Feras; Alshehri, Fahad; Ballo, Ahmed M

    2016-10-01

    The aim of this study was to assess the esthetic outcome of maxillary anterior single implants by comparing the esthetic perception of dental professionals and patients. Twenty-three patients with single implants in the esthetic zone were enrolled in this study. Dentists of four different dental specialties (Three orthodontists, three oral surgeons, three prosthodontists, and three periodontists) evaluated the pink esthetic score (PES)/white esthetic score (WES) for 23 implant-supported single restorations. The satisfactions of the patients on the esthetic outcome of the treatment have been evaluated according to the visual analog scale (VAS). The mean total PES/WES was 12.26 ± 4.76. The mean PES was 6.45 ± 2.78 and mean WES was 5.80 ± 2.82. There was a statistically significant difference among the different specialties for WES ( P esthetic perception, thereby providing rationales for involving patients in the treatment plan to achieve higher levels of patient satisfaction.

  10. Maxillary arch rehabilitation using implant-supported computer-assisted design-computer-assisted manufacturing-milled titanium framework

    Directory of Open Access Journals (Sweden)

    Tulika S Khanna

    2017-01-01

    Full Text Available Esthetic and functional rehabilitation of completely edentulous maxillary arch with fixed implant supported prosthesis is a challenging task. Newer technologies such as computer assisted design computer assisted manufacturing (CAD CAM and cone beam conventional tomography play an important role in achieving predictable results. Full mouth porcelain fused to metal (PFM individual crowns on CAD CAM milled titanium framework provides positive esthetic and functional outcome. This is a case report of rehabilitation of partially edentulous maxillary arch patient. Staged rehabilitation of this patient was planned. In the first stage, root canal treatment of key abutment teeth was done, nonsalvageable teeth were removed, and immediate interim overdenture was provided. In the second stage, five Nobel Biocare dental implants were placed. After integration impressions were made, CAD CAM milled titanium bar was fabricated. Individual PFM crowns were made and cemented. This method gives better esthetic compared to acrylic fused to metal hybrid prosthesis with the advantage of retrievability just like screw retained prosthesis. Hence, this technique is good for rehabilitation of patients with high esthetic demands.

  11. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  12. Maxillary Overdentures Supported by Anteriorly or Posteriorly Placed Implants Opposed by a Natural Dentition in the Mandible : A 1-Year Prospective Case Series Study

    NARCIS (Netherlands)

    Slot, Jan; Raghoebar, Gerry M.; Vissink, Arjan; Meijer, Henny J. A.

    Background: For maxillary overdenture therapy, treatment guidelines are missing. There is a need for longitudinal studies. Purpose: The purpose of this 1-year prospective case series study was to assess the treatment outcome of maxillary overdentures supported by six dental implants opposed by

  13. A case report of incidental finding of fungus ball on CBCT of maxillary sinus in treatment planning of dental implant

    International Nuclear Information System (INIS)

    Lee, Byung Do

    2010-01-01

    This report was to show the radiographic appearances of the fungus ball in a paranasal sinus and to emphasize the scan area of cone beam computed tomography (CBCT) to detect the calcification in the paranasal sinus. A seventy four-year-old woman visited our department for the implant rehabilitation at both maxillary posterior edentulous region. Pre-operative radiographic examinations including the panoramic, CBCT, and multidector CT images were taken. An opacification in the right maxillary sinus was observed on the multiplanar image of CBCT, however the pre-determined scan area of CBCT in this report hardly showed the calcifications at the central portion of the maxillary sinus. The opacification in the maxillary sinus could be misdiagnosed as chronic maxillary sinusitis if the calcification of fungus ball was not simultaneously detected. The scan area of pre-operative CBCT needs to be enough to scan the paranasal sinus from top to bottom.

  14. Terminal Posterior Tilted Implants Planned as a Sinus Graft Alternative for Fixed Full-Arch Implant-Supported Maxillary Restoration: A Case Series with 10- to 19-Year Results on 44 Consecutive Patients Presenting for Routine Maintenance.

    Science.gov (United States)

    Fortin, Yvan; Sullivan, Richard M

    2017-02-01

    Posterior maxillary tilted implants are gaining prevalence as an alternative to sinus grafts supporting fixed maxillary restorations. This paper reports long-term results after loading using this technique. Consecutive patients presenting for either routine hygiene maintenance or unplanned emergency care who had received tilted implants as a sinus graft alternative to support fixed fully implant-supported restoration of an edentulous maxilla and were followed for a minimum of 10 years from initial implant placement were included in this evaluation. Forty-four patients were identified: 40 with bilateral tilted implants and 4 with one tilted and one axial posterior implant. Eight patients received one-piece fixed porcelain-to-gold screw-retained restorations, and thirty-six patients received a fully implant-supported patient-removable Marius Bridge. Seventy-nine out of 84 originally loaded posterior tilted implants survived a minimum of 10 years loading; one tilted implant was lost at 10 years. Eight additional posterior implants were placed for either these lost tilted posterior implants or as proactive supplemental support; one of these replacement tilted implants survived for at least 10 years and is included in the data. All patients have maintained continuous fixed function throughout the follow-up period. Forty-one out of 44 patients continue with the original restoration, 33 without modification or removal of the fixed restoration or implant-connecting bar. One porcelain-to-gold and seven Marius Bridges had framework modifications to accommodate additional implants; 3 Marius Bridge restorations were replaced with a newer generation. Within the limits of this retrospective study, the results show that continuous fixed function of fully implant-supported maxillary restorations using posterior tilted implants in terminal positions of support as a sinus graft alternative combined with axial anterior implants is possible over a prolonged period. Loss of a posterior

  15. The effect of number and distribution of unsplinted maxillary implants on the load transfer in implant-retained maxillary overdentures: an in vitro study.

    Science.gov (United States)

    Damghani, Sahar; Masri, Radi; Driscoll, Carl F; Romberg, Elaine

    2012-06-01

    There is little information as to how the number and distribution of implants affect the amount of load transmitted to the palate in implant-retained maxillary overdentures. The purpose of this study was to evaluate the effect of the number and distribution of dental implants on the load transmitted to the palate. Eight implant analogues were placed in a replica of an average sized edentulous maxilla corresponding to the position of canines, first and second premolars, and first molars. The anteroposterior distance between the centers of implants in each quadrant was 8 mm. Fifteen denture bases were fabricated to fit the edentulous maxilla analogue. The denture bases were attached to the oral analogue using 6 different configurations of attachments (6 groups): Either no Locator attachments were used (control group), or the 2 most anterior attachments were attached, or 4 implants were engaged with a distance of 8, 16, or 24 mm between the centers of implants on left and right side, and finally, when all 8 attachments were activated. A force-measuring sensor was used to measure the force transmitted to the palate when a static force of 245 N was applied on the occlusal rims of the denture bases. Data (Newtons) were analyzed using 1-way ANOVA and Tukey's HSD test α=.05). The mean (SD) amount of force measured on the palate when the overdentures were supported by 4 Locator attachments; [49.84 (26.52) at 8 mm spacing], [24.42 (15.05) at 16 mm spacing], [35.66 (22.94) at 24 mm spacing] was significantly lower than when no attachments [90.98 (20.20), control], or when 2 Locator attachments were used [76.07 (27.63)] (Poverdentures were supported by 8 Locator attachments, the force measured on the palate [20.67(16.06) N] was significantly lower than that for the control group (Poverdentures supported by 2 Locator attachments (Poverdentures supported by 4 Locator attachments when the distance between the anterior and posterior implants was 8 mm P=.006). The distribution of

  16. Exfoliation of GaAs caused by MeV 1H and 4He ion implantation at left angle 100 right angle , left angle 110 right angle axial and random orientations

    International Nuclear Information System (INIS)

    Rauhala, E.; Raeisaenen, J.

    1994-01-01

    The exfoliation procedure of the ion range determination of gaseous implants in single crystal GaAs is investigated. The correlation of the observed crater depth with the ion range is studied for random, left angle 100 right angle and left angle 110 right angle axial orientation high dose implantations of 1.5-2.5 MeV 1 H and 4 He ions. Depending on the experimental conditions, the crater depths corresponded to range values between the modal range and the range maximum. The observed crater depths could be related to the actual He concentration depth distributions by determining the profiles of the 4 He implants by 2.7 MeV proton backscattering. The implantation parameters affecting the exfoliation process, and especially the increase rate of the sample temperature, are investigated. The range distribution parameters for the 1.5 MeV 4 He implants are presented. ((orig.))

  17. Maxillary sinus by-pass with tilted implants via tapered-screw bone expanders in low density bone: one year follow -up of a case series.

    Science.gov (United States)

    Andreasi Bassi, M; Andrisani, C; Lopez, M A; Gaudio, R M; Lombardo, L; Lauritano, D

    2016-01-01

    In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors named the procedure: Tilted Implant Expansion Osteotomy (TIEO). Fifteen patients (10 females and 5 males, mean age 47.8±8.15 years) with distal edentulous maxillae were enrolled in this study. For each edentulous site 2 implants were placed, the anterior implant in the area of the most anterior missing tooth while, the posterior implant, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 34 cylindrical two-piece implants were placed, 17 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 4-6 months, the second stage surgery was performed. The cases were finalized by metal-ceramic cementable restorations with a variable number of elements, from 2 to 4, without any cantilever element. The post finalization follow-up was at 12 months. Survival rate was 100% since no fixtures were lost. At the one-year follow-up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. TIEO is a promising surgical procedure for oral rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques.

  18. Implantation of the maxillary antrum for delivery of iridium brachytherapy and microwave induced hyperthermia

    International Nuclear Information System (INIS)

    Coughlin, C.T.; Wong, T.Z.; Geurkink, N.

    1985-01-01

    A 63 year-old male was referred tp Dartmouth in March 1984 for a locally advanced recurrent squamous cell carcinoma of the left maxillary antrum. This had been initially diagnosed in January 1983 by a Caldwell-Luc procedure and had failed partial resection, external radiation therapy, and multiagent chemotherapy. Our initial evaluation revealed disease replacing the left maxillary antrum, extending into the pterygomaxillary fossa, the lateral aspect of the superior alveloar ridge, and into the soft palate. He was taken to the operating room and under general anesthesia was implanted the 7 catheters through this tumor volume. Two days later a therapeutic (>42 0 C for 1 hour) hyperthermia treatment was administered followed by iridium placement. A second heating was performed upon removal of the iridium and was accomplished without major side effects. Thermometry data and follow-up are presented

  19. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

    Science.gov (United States)

    Qamheya, Ala Hassan A; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

  20. Asymmetric extractions in a patient with a hopeless maxillary central incisor, followed by treatment with mini-implant anchorage.

    Science.gov (United States)

    Jung, Min-Ho

    2018-05-01

    Premolar extraction is 1 option for treatment of patients with malocclusion and severe crowding or protrusion. When the patient has missing or hopeless teeth other than premolars, it is possible to consider removal of those teeth to use the space to decrease crowding. A 15-year-old girl sought treatment for severe crowding. She had already lost her maxillary right first premolar as a result of caries 1 year previously and had a hopeless maxillary right central incisor. Her mandibular left first molar still caused discomfort even after endodontic treatment. Extractions of the maxillary right central incisor and mandibular right first premolar and left first molar were chosen to resolve the occlusion problems. Orthodontic mini-implants were placed to translocate the maxillary left central incisor across the midpalatal suture to use the space in the maxillary right quadrant to relieve the crowding. Although a different extraction option was used in each quadrant, the final occlusion was acceptable. After debonding, porcelain crowns were placed on the anterior teeth to improve esthetics. The treatment result remained stable after 2 years of retention. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Quantitation of maxillary remodeling. 2. Masking of remodeling effects when an "anatomical" method of superimposition is used in the absence of metallic implants.

    Science.gov (United States)

    Baumrind, S; Korn, E L; Ben-Bassat, Y; West, E E

    1987-06-01

    We report the results of a study aimed at quantifying the differences in the perceived pattern of maxillary remodeling that are observed when different methods are used to superimpose maxillary images in roentgenographic cephalometrics. In a previous article, we reported cumulative changes in the positions of anterior nasal spine (ANS), posterior nasal spine (PNS), and Point A for a sample of 31 subjects with maxillary metallic implants. Measurements had been made on lateral cephalograms taken at annual intervals relative to superimposition on the implants. In the present article, we quantify the differences in the perceived displacement of the same landmarks in the same sample when a standard "anatomical best bit" rule was used in lieu of superimposition on the implants. The anatomical best fit superimposition as herein defined was found in this sample to lose important information on the downward remodeling of the superior surface of the maxilla that had been detected when the implant superimposition was used. In fact, we observed a small artifactual upward displacement of the ANS-PNS line. In the anteroposterior direction, the tendency toward backward displacement of skeletal landmarks through time that had been detected with the implant superimposition was replaced by a small forward displacement of ANS and Point A together with reduced backward displacement of PNS. To the extent that the implant superimposition is to be considered the true and correct one, the anatomical best fit superimposition appears to understate the true downward remodeling of the palate by an average of about 0.3 and 0.4 mm per year, although this value differs at different ages and timepoints. The anatomical best fit superimposition also misses entirely the small mean tendency toward backward remodeling that was observed when the implant superimposition was used. In situations in which there are no implants, clinicians and research workers must necessarily continue to use anatomically

  2. Applications of cone-beam computed tomography to assess the effects of labial crown morphologies and collum angles on torque for maxillary anterior teeth.

    Science.gov (United States)

    Kong, Wei-Dong; Ke, Jun-Yu; Hu, Xiang-Quan; Zhang, Wu; Li, Shu-Shu; Feng, Yi

    2016-11-01

    Currently, cone-beam computed tomography (CBCT) has been widely used because of its capacity to evaluate the anatomic structures of the maxilla, mandible, and teeth in 3 dimensions. However, articles about the use of CBCT to evaluate the relationships between the morphology of individual teeth and torque expression remain rare. In this study, we aimed to determine the influence of labial crown morphologies and collum angles on torque for maxillary anterior teeth using CBCT. A total of 206 extracted maxillary anterior teeth were selected to establish scanning models using dental wax, and they were scanned by CBCT. Three-dimensionally reconstructed images and median sagittal sections of the teeth were digitized and analyzed with AutoCAD software (Autodesk, San Rafael, Calif). The angle α, formed by the intersection of the tangent at a certain vertical height on the labial surface from the incisal edge with the crown long axis, and the collum angle, were measured. The variations in angle α at different heights from the incisal edge for the same type of tooth were statistically significantly different (P <0.001). Moreover, the variations between collum angles and 0° for any type of maxillary anterior tooth were statistically significant (P <0.01). This study suggested that there are great differences in labial crown morphologies and collum angles for maxillary anterior teeth between persons, indicating that the morphologies of these teeth do play important roles in torque variations. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  3. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    Directory of Open Access Journals (Sweden)

    Ala Hassan A. Qamheya

    2015-01-01

    Full Text Available Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC material in teeth construction to rehabilitate a complete denture wearer patient.

  4. Stress analysis of implant-bone fixation at different fracture angle

    Science.gov (United States)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  5. Evaluation of stress patterns on maxillary posterior segment when intruded with mini implant anchorage: A three-dimensional finite element study

    Directory of Open Access Journals (Sweden)

    Nikhita Pekhale

    2016-01-01

    Full Text Available Introduction: The aim of this study is to evaluate stress and displacement effects of maxillary posterior intrusion mechanics with mini-implant anchorage by using finite element method. Materials and Methods: A computer stimulation of three-dimensional model maxilla with all teeth, PDL, bone, mini-implants, brackets, arch wire, force element, and transpalatal arch was constructed on the basis of average anatomic morphology. Finite element analysis was done to evaluate the amount of stress and its distribution during orthodontic intrusive force. Results: Increased Von Mises stress values were observed in mesio-cervical region of first molar. The middle third of second premolar and second molar and regions adjacent to force application sites also showed relatively high stress values. Minimum stress values were observed in apical region of first premolar as it is away from force application. Conclusion: Using three mini-implant and transpalatal arches, this study demonstrates that significant amount of true intrusion of maxillary molars could be obtained with lesser concentration of stresses in the apical area recorded.

  6. Immediate provisional restoration of an implant placed in a fresh primary maxillary canine extraction socket: a case report.

    Science.gov (United States)

    Turkyilmaz, Ilser; Shapiro, Vladimir

    2011-01-01

    This study describes a clinical case in which a primary maxillary canine with both mobility and root resorption was replaced with an immediately restored dental implant placed into the fresh extraction socket. The implant achieved high primary stability, as determined by resonance frequency analysis, and it was immediately restored with a provisional acrylic resin crown with no centric occlusion. An all-ceramic permanent crown replaced the provisonal crown four months after implant surgery. The implant was stable and no periapical radiolucencies, bleeding on probing, or pathologic probing depth were recorded after one year. The peri-implant soft tissue level appeared stable, and the interdental papillae were preserved, contributing to an optimum final esthetic result. This case supports the use of single implants for the replacement of extracted primary teeth, especially in areas where esthetics is a high priority. The immediate provisional crown maintained soft tissue contours and papillary height.

  7. Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach

    Directory of Open Access Journals (Sweden)

    A. Sumathi Felicita

    Full Text Available ABSTRACT Objective: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. Methods: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. Results: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5o to 16o from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. Conclusion: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios.

  8. HEART ELECTRICAL AXIS Α ANGLE VALUES DISTRIBUTION IN PATIENTS, UNDERGOING PERMANENT PACEMAKER IMPLANTATION

    Directory of Open Access Journals (Sweden)

    O. S. Voronenko

    2016-06-01

    Full Text Available 52 patients (24 male and 28 female aged 71 ± 8 years, underwent permanent pacemaker implantation were included in the study. Analysis of heart electrical axis (HEA α angle values distribution was carried out in three dimensions in patience before and after pacemaker (PM implantation. The data processed in Microsoft Excel with calculation of the average and it’s standard deviation. Significance of differences in data before and after PM implantation was assessed using Friedman ANOVA test and Kendall concordance coefficient. It was found, that α angle values distribution in patients with implanted PM is transformed from a unimodal to bimodal on the permanent cardiac pacing background. It’s assumed, that α angle changes resulting due to right ventricular electrode positioning options during PM implantation. Clarification of the nature of this change requires a special study.

  9. Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge.

    Science.gov (United States)

    Mounir, M; Atef, M; Abou-Elfetouh, A; Hakam, M M

    2018-05-01

    The aim of this study was to assess two new protocols for single-stage rehabilitation of the severely atrophic maxillary ridge using customized porous titanium or polyether ether ketone (PEEK) sub-periosteal implants. Ten patients with a severely atrophic anterior maxillary alveolar ridge were divided randomly into two groups (five patients in each) to receive customized sub-periosteal implants fabricated via CAD/CAM technology: group 1, porous titanium implants; group 2, PEEK implants. Prosthetic loading with fixed acrylic bridges was performed 1 month postoperative. The implants were followed-up for 12 months and evaluated for the presence of any sign of radiographic bone resorption, mobility, infection, prosthetic fracture, or implant exposure. The immediate postoperative period was uneventful except for one case complicated by wound dehiscence in group 1. At 12 months, all implants were functionally stable and the patients were comfortable with the prostheses. No signs of radiographic bone resorption, mobility, infection, or prosthetic fracture were observed. Within the limitations of this study, the application of customized porous titanium and PEEK sub-periosteal implants produced through CAD/CAM technology appears to be an acceptable method for single-stage prosthetic rehabilitation of the severely atrophic edentulous anterior maxilla. This study was awarded the best case study at the academy of osseintegration annual meeting 2017, Orlando, Florida. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Implant-retained maxillary overdentures.

    Science.gov (United States)

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  11. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    Science.gov (United States)

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (Pabutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (Pabutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Clinical and radiographic evaluation of maxillary central incisors exposure in patients undergoing maxillary advancement

    Directory of Open Access Journals (Sweden)

    Guilherme dos Santos Trento

    2015-12-01

    Full Text Available Abstract Introduction: Patients with dentofacial deformities may undergo orthodontic or orthodontic-surgical treatment. Both modalities can affect esthetics. Objective: This study aims to evaluate clinical and radiographic changes in exposure of maxillary central incisors occurring after orthognathic surgery for maxillary advancement. Methods: A total of 17 patients who underwent orthognathic surgery for maxillary advancement between September, 2010 and July, 2011 were selected. Exposure of maxillary central incisors was evaluated clinically and by lateral cephalograms. Measurements were taken one week before and three months after surgery. Data were paired in terms of sex, age, nasolabial angle, height and thickness of the upper lip, the amount of maxillary advancement, clinical exposure and inclination of maxillary central incisor by statistical tests (CI 95%. Results: After maxillary advancement, incisor clinical exposure had increased even with relaxed lips and under forced smile. Moreover, there was a mean increase of 23.33% revealed by lateral cephalograms. There was an inverse correlation between upper lip thickness and incisors postsurgical exposure revealed by radiographic images (p = 0.002. Conclusions: Significant changes in the exposure of maxillary central incisors occur after maxillary advancement, under the influence of some factors, especially lip thickness.

  13. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  14. Relationship between crown-root angulation (collum angle) of maxillary central incisors in Class II, division 2 malocclusion and lower lip line.

    Science.gov (United States)

    Srinivasan, Bhadrinath; Kailasam, Vignesh; Chitharanjan, Arun; Ramalingam, Arthi

    2013-01-01

    The present study aimed to measure the magnitude of the collum angle (crown-root angulation) of maxillary central incisors present in Class II, division 2 malocclusion and to relate the changes in its magnitude with variations in the lower lip line. A set of 120 conventional lateral cephalograms were selected and divided into three groups of 40 each based on the type of malocclusion presented: Class II, division 2 (group 1); Class II, division 1 (group 2); and Class I (group 3). The collum angle of the maxillary central incisor was measured, and the lower lip line was recorded. Analysis of variance (ANOVA) revealed that the mean collum angle was statistically significantly different in the three groups. The mean collum angle was greatest in Class II, division 2 malocclusion (group 1). The mean collum angles were 3.24 ± 4.69 degrees, 0.95 ± 1.06 degrees, and 1.05 ± 1.50 degrees in groups 1, 2, and 3 respectively. In χ ² test comparison of the location of the lower lip line (incisal, middle, or apical third of the central incisor) among the three groups, the lower lip line was found to contact the middle third of the central incisor most frequently in Class II, division 2 malocclusion. ANOVA followed by Tukey honestly significant difference (HSD) test showed that the mean collum angle is significantly increased when the lower lip is in the middle third (P lower lip line suggest a probable etiologic role of the lower lip line in the development of the collum angle.

  15. Maxillary sinus floor elevation surgery with BioOss (R) mixed with a bone marrow concentrate or autogenous bone : test of principle on implant survival and clinical performance

    NARCIS (Netherlands)

    Rickert, D.; Vissink, A.; Slot, Jan; Sauerbier, S.; Meijer, H. J. A.; Raghoebar, G. M.

    The purpose of this study was to assess implant survival and 1-year clinical performance of implants placed in the posterior maxilla that had been subjected to maxillary sinus floor elevation surgery with bovine bone mineral (BioOss (R)) mixed with autogenous bone marrow concentrate or autogenous

  16. Maxillary reconstruction with bone transport distraction and implants after partial maxillectomy.

    Science.gov (United States)

    Castro-Núñez, Jaime; González, Marcos Daniel

    2013-02-01

    Maxillary and mandibular bone defects can result from injury, congenital defect, or accident, or as a consequence of surgical procedures when treating pathology or defects affecting jaw bones. The glandular odontogenic cyst is an infrequent type of odontogenic cyst that can leave a bony defect after being treated by aggressive surgical means. First described in 1987 by Padayachee and Van Wyk, it is a potentially aggressive entity, having a predisposition to recur when treated conservatively, with only 111 cases having been reported hitherto. Most reports emphasize its clinical, radiographic, and histologic features, including a few considerations on rehabilitation for these patients. The aim of this article is to present the case of a 24-year-old male patient who, in 2001, was diagnosed with a glandular odontogenic cyst and to focus on the surgical approach and rehabilitation scheme. We performed an anterior partial maxillectomy. The osseous defect was treated using bone transport distraction. Dental and occlusal rehabilitation was achieved with titanium implants over transported bone and an implant-supported overdenture. A 9-year follow-up shows no evidence of recurrence of the pathology, adequate shape and amount of bone, functional occlusal and dental rehabilitation, and patient's satisfaction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Maxillary Tuberosity Reconstruction with Transport Distraction Osteogenesis

    Directory of Open Access Journals (Sweden)

    F. Ugurlu

    2012-01-01

    Full Text Available Severe bone loss due to pathology in the maxillary tuberosity region is a challenging problem both surgically and prosthetically. Large bone grafts have a poor survival rate due to the delicate bony architecture in this area and presence of the maxillary sinus. Our case presentation describes a new technique for reconstructing severe bony defect in the maxillary tuberosity with horizontal distraction osteogenesis in a 45-year-old man. A 4×6×3cm cyst was discovered in the left maxillary molar region and enucleated. Three months postoperatively, the area had a severe bone defect extending to the zygomatic buttress superiorly and hamular notch posteriorly. Three months later, a bone segment including the right upper second premolar was osteotomised and distracted horizontally. The bone segment was distracted 15 mm distally. After consolidation, implants were placed when the distractor was removed. A fixed denture was loaded over the implants after 3 months. Complete alveolar bone loss extending to the cranial base can be reconstructed with transport distraction osteogenesis. Distalisation of the alveolar bone segment adjacent to the bony defect is an easy method for reconstructing such severe defects.

  18. Maxillary and mandibular immediately loaded implant-supported interim complete fixed dental prostheses on immediately placed dental implants with a digital approach: A clinical report.

    Science.gov (United States)

    Lewis, Ryan C; Harris, Bryan T; Sarno, Robert; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2015-09-01

    This clinical report describes the treatment of maxillary and mandibular immediate implant placement and immediately loaded implant-supported interim complete fixed dental prostheses with a contemporary digital approach. The virtual diagnostic tooth arrangement eliminated the need for a customized radiographic template, and the diagnostic data collection required for computer-guided surgery (digital diagnostic impressions, digital photographs, and a cone beam-computed tomography [CBCT] scan) was completed in a single visit with improved workflow efficiency. Computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated surgical templates and interim prosthesis templates were made in a dental laboratory to facilitate computer-guided surgery and the immediate loading process. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Combination of straight and tilted implants for supporting screw-retained dental prostheses in atrophic posterior maxillae: A 2-year prospective study.

    Science.gov (United States)

    Casar-Espinosa, Juan-Carlos; Castillo-Oyagüe, Raquel; Serrera-Figallo, María Ángeles; Garrido-Serrano, Roberto; Lynch, Christopher D; Menéndez-Collar, Manuel; Torres-Lagares, Daniel; Gutiérrez-Pérez, José-Luis

    2017-08-01

    To evaluate the two-year survival rate (SR) and marginal bone loss (MBL) of fixed dental prostheses (FDPs) supported by straight (S) and tilted (T) implants under the influence of diverse study variables. A prospective investigation comprising 21 patients provided with a total of 27 maxillary screw-retained restorations fixed to 70 dental implants was developed. Two groups of implants were considered depending on their inclination with respect to the occlusal plane: Group 1 (S, n=37): straight/axial implants and Group 2 (T, n=33): tilted/angled fixations. Each FDP was supported by a combination of S and T implants. SR and MBL were assessed at the time of loading and two years after surgery. Patient-, surgical- and/or rehabilitation-related information was gathered. Data were statistically analysed at the α=0.05 significance level. After 24 months, a 100% SR was achieved and the MBL of S and T implants were statistically similar. T implants located in the molar region showed lower MBL than did those replacing premolars (p=0.031). Upright and angled fixations inserted at posterior maxillary areas resulted in comparable survival rates and peri-implant MBL after two years. The marginal bone resorption around tilted implants depended on their location. Screw-retained restorations fixed to straight and tilted implants seem to be a safe treatment option in posterior atrophic maxillae. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Five-year outcome of a retrospective cohort study on the rehabilitation of completely edentulous atrophic maxillae with immediately loaded zygomatic implants placed extra-maxillary.

    Science.gov (United States)

    Maló, Paulo; Nobre, Miguel de Araújo; Lopes, Armando; Ferro, Ana; Moss, Steven

    2014-01-01

    To report retrospectively on the 5-year follow-up results of the rehabilitation of complete edentulous atrophied maxillae, using extra-maxillary zygomatic implants alone or in combination with conventional implants. This retrospective report includes an initial cohort of 39 patients (30 women and 9 men), with a mean age of 53 years, followed for 5 years. The patients were rehabilitated with 39 fixed prostheses and 169 implants (92 zygomatic implants inserted extra-maxillary and 77 conventional dental implants). A provisional prosthesis was manufactured and attached via multiunit abutments secured to the implants on the same day as implant placement. According to patient desires and each clinical situation, either an acrylic resin, a metal-acrylic or metal-ceramic final prosthesis was inserted approximately 6 months after implant placement. Outcome measures were: prosthesis success; implant success; complications; probing pocket depths; marginal bleeding; and marginal bone levels (only for conventional implants). Data were analysed with descriptive statistics. Two patients died after 8 and 30 months of follow-up due to causes unrelated to their oral rehabilitations, and 5 patients dropped out of the study. No prosthesis was lost; one zygomatic implant was removed after 46 months of follow-up, giving cumulative success rates of 97% and 98.8% (patient and implant related, respectively). Twelve complications occurred in 12 patients: 5 sinus infections in 5 patients, all with a previous history of sinusitis and whose sinus membrane was disrupted during surgery; one oroantral communication (leading to removal of the implant), 2 all acrylic resin prostheses fractures, 1 ceramic crown fracture (on a metal-ceramic prosthesis); and 3 screw loosenings. Bleeding on probing was recorded in 6 patients (13 implants). Probing pocket depths >4 mm were present in 13 patients (23 implants) at 5 years of follow-up. The average (standard deviation) marginal bone loss on conventional

  1. Impression of multiple implants using photogrammetry: description of technique and case presentation.

    Science.gov (United States)

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz; Peñarrocha, María

    2014-07-01

    To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions - angles and distances - of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient's mouth using the Sheffield test and the screw resistance test. Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient.

  2. Esthetic evaluation of maxillary single-tooth implants in the esthetic zone

    Science.gov (United States)

    Cho, Hae-Lyung; Lee, Jae-Kwan; Um, Heung-Sik

    2010-01-01

    Purpose The aim of this study is to assess the influence exerted by the observer's dental specialization and compare patients' opinion with observers' opinion of the esthetics of maxillary single-tooth implants in the esthetic zone. Methods Forty-one adult patients, who were treated with a single implant in the esthetic zone, were enrolled in this study. Eight observers (2 periodontists, 2 prosthodontists, 2 orthodontists and 2 senior dental students) applied the pink esthetic score (PES)/white esthetic score (WES) to 41 implant-supported single restorations twice with an interval of 4 weeks. We used a visual analog scale (VAS) to assess the patient's satisfaction with the treatment outcome from an esthetic point of view. Results In the PES/WES, very good and moderate intraobserver agreements were noted between the first and second rating. The mean total PES/WES was 11.19 ± 3.59. The mean PES was 5.17 ± 2.29 and mean WES was 6.02 ± 1.96. In the total PES/WES, the difference between the groups was not significant. However, in the WES, the difference between the groups was significant and prosthodontists were found to have assigned poorer ratings than the other groups. Periodontists gave higher ratings than prosthodontists and senior dental students. Orthodontists were clearly more critical than the other observers. The statistical analysis revealed statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth. However, the correlation between the total PES/WES and the VAS score for the first premolar was not statistically significant. Conclusions The PES/WES is an objective tool in rating the esthetics of implant supported single crowns and adjacent soft tissues. Orthodontists were the most critical observers, while periodontists were more generous than other observers. The statistical analysis revealed a statistically significant correlation between patients' esthetic perception and dentists

  3. Finite element analysis and clinical complications in mandibular implant-overdentures opposing maxillary dentures.

    Science.gov (United States)

    Khuder, Tameem; Yunus, Norsiah; Sulaiman, Eshamsul; Dabbagh, Ali

    2017-11-01

    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint.

    Science.gov (United States)

    Hung, Li-Kun; Su, Kuo-Chih; Lu, Wen-Hsien; Lee, Cheng-Hung

    2017-08-01

    A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.

  5. Aspergilloma of the maxillary sinus: report of a case

    International Nuclear Information System (INIS)

    Kang, Ju Han; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan; Yu, Jae Jung

    2010-01-01

    Aspergilloma of the paranasal sinus is a non-invasive form of aspergillosis, most often in the maxillary sinus. This case presents an 86-year-old female with aspergilloma of the left maxillary sinus. The patient's chief complaint was intermittent pain on the left maxillary first premolar area. A radiopacification of the left maxillary sinus was observed on the panoramic radiograph. Cone-beam computed tomography revealed complete radiopacification of the left maxillary sinus and scattered multiple radiopaque mass inside the lesion. Biopsy was performed under local anesthesia. On microscopic examination, numerous fungal hyphae, which branch at acute angle, were observed. The diagnosis was made as an aspergilloma based on the histopathologic examination.

  6. Quantitation of maxillary remodeling. 1. A description of osseous changes relative to superimposition on metallic implants.

    Science.gov (United States)

    Baumrind, S; Korn, E L; Ben-Bassat, Y; West, E E

    1987-01-01

    Lateral skull radiographs for a set of 31 human subjects were examined using computer-aided methods in an attempt to quantify modal trends of maxillary remodeling during the mixed dentition and adolescent growth periods. Cumulative changes in position of anterior nasal spine (ANS), posterior nasal spine (PNS), and Point A are reported at annual intervals relative to superimposition on previously placed maxillary metallic implants. This in vivo longitudinal study confirms at a high level of confidence earlier findings by Enlow, Björk, Melsen, and others to the effect that the superior surface of the maxilla remodels downward during the period of growth and development being investigated. However, the inter-individual variability is relatively large, the mean magnitudes of change are relatively small, and the rate of change appears to diminish by 13.5 years. For the 19 subjects for whom data were available for the time interval from 8.5 to 15.5 years, mean downward remodeling at PNS was 2.50 mm with a standard deviation of 2.23 mm. At ANS, corresponding mean value was 1.56 mm with a standard deviation of 2.92 mm. Mean rotation of the ANS-PNS line relative to the implant line was 1.1 degree in the "forward" direction. However, this rotational change was particularly variable with a standard deviation of 4.6 degrees and a range of 11.3 degrees "forward" to 6.7 degrees "backward." The study provides strong evidence that the palate elongates anteroposteriorly mainly by the backward remodeling of structures located posterior to the region in which the implants were placed. There is also evidence that supports the idea of modal resorptive remodeling at ANS and PNS, but here the data are somewhat more equivocal. It appears likely, but not certain, that there are real differences in the modal patterns of remodeling between treated and untreated subjects. Because of problems associated with overfragmentation of the sample, sex differences were not investigated.

  7. Efficacy and feasibility of frontozygomatic angle approach for extra oral maxillary nerve block in oral surgery: a descriptive clinical trial.

    Science.gov (United States)

    Radder, Kiran; Shah, Ashwin; Fatima, Shereen; Kothari, Chaitanya; Zakaullah, Syed; Siddiqua, Aaisha

    2014-09-01

    Pain control is an integral part of minor oral surgery and maxillary/mandibular nerve blocks have proved promising in achieving the same. Although intra oral techniques of maxillary nerve block are common and are widely used, there are certain inherent disadvantages and potential complications. Less commonly described in the literature, the extra oral techniques have a wide spectrum of indications as well as can be more advantageous than the intra oral approach. This prospective clinical trial is an attempt to evaluate the feasibility and the efficacy of the extra oral frontozygomatic approach to the foramen rotundum to block the maxillary nerve. Sample size was 100 patients and the inclusion criteria were patients of ASA I or II category who needed extraction of a minimum of 4 maxillary teeth in the same quadrant in a single sitting while exclusion criteria were patients with a history of allergy to local anesthesia, medically compromised patients in whom dental extraction was contraindicated. Mean age was 71.9 years and 56 patients were males while 44 were females. Only a single quadrant (first or second) was chosen as the operative site in each patient and local anaesthesia was secured using a 21 gauge 89 mm long spinal needle with frontozygomatic angle approach and the parameters used were pain experienced during the injection, onset of subjective symptoms, time required for the peak effect (objective symptoms), pain during extraction and the duration of anesthesia. All the parameters were expressed as mean values with standard deviations. A successful anesthesia was secured in first attempt in 98 patients while in 2 patients, the procedure had to be repeated owing to the difficulty in reaching the target site. A majority of the patients i.e., 71 % scored 0-2 (no pain) on visual analogue scale (VAS) while only 2 patients experienced a moderate degree of pain. Subjective symptoms were reported in 27.24 s (mean value) and 12.93 s (mean value) in the palate

  8. Trans-sinusal maxillary distraction for correction of midfacial hypoplasia: long-term clinical results.

    NARCIS (Netherlands)

    Nadjmi, N.; Schutyser, F.A.C.; Erum, R. van

    2006-01-01

    Maxillary distraction osteogenesis is indicated in severe angle class III malocclusions, and severe maxillary hypoplasia among some cleft patients and other craniofacial deformities. Twenty patients, aged 8-48 years (mean 17.8+/-10.5 SD) with maxillary and midfacial hypoplasia were treated. The

  9. Maxillary distraction osteogenesis using Le Fort I osteotomy without intraoperative down-fracture.

    Science.gov (United States)

    Yamauchi, K; Mitsugi, M; Takahashi, T

    2006-06-01

    The aim of this study is to present a technique for maxillary distraction osteogenesis using Le Fort I osteotomy without down-fracture. Six cleft-related patients suffering from severe midfacial deficiency were treated with maxillary distraction osteogenesis. The RED II system was chosen as the extraoral device and the Leipzig retention plate system to anchor the maxillary segment. Maxillary distraction osteogenesis was successful in all cases. Cephalometric and clinical evaluation after an average follow-up period of 1 year showed stable results with respect to skeletal and dental relationships. The SNA angle increased from 72.3 degrees to 81.4 degrees and the ANB angle increased by 11.0 degrees immediately after removing the distraction device. After 1 year, the sagittal bone gain remained and the SNA angle had decreased by 0.8 degrees . This technique seems to minimize the risk of the surgical procedure and shorten the operation time. It may become an alternative method for the treatment of patients with severe midfacial hypoplasia.

  10. Titanium Granules for Augmentation of the Maxillary Sinus

    DEFF Research Database (Denmark)

    Lyngstadaas, Ståle Petter; Verket, Anders; Pinholt, Else Marie

    2015-01-01

    BACKGROUND: Biomaterials are commonly used to augment the maxillary sinus floor prior to or in conjunction with dental implant installation. Recently, porous titanium granules (PTGs) have been used in oral implant surgery to stabilize implants and function as an osteoconductive matrix. PURPOSE...... in the study. RESULTS: One immobile implant was removed. The mean marginal bone loss was 0.5 mm and 0.8 mm, on the mesial and distal side, respectively. Histologically, all biopsies demonstrated bone ingrowth. CONCLUSIONS: The results suggest that PTG can be safely and effectively used as augmentation material...

  11. Aspergilloma of the maxillary sinus: report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ju Han; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [School of Dentistry, Kung Hee University, Seoul (Korea, Republic of); Yu, Jae Jung [Kangdong Scared Heart Hospital, Hallym Medical Center, Seoul (Korea, Republic of)

    2010-12-15

    Aspergilloma of the paranasal sinus is a non-invasive form of aspergillosis, most often in the maxillary sinus. This case presents an 86-year-old female with aspergilloma of the left maxillary sinus. The patient's chief complaint was intermittent pain on the left maxillary first premolar area. A radiopacification of the left maxillary sinus was observed on the panoramic radiograph. Cone-beam computed tomography revealed complete radiopacification of the left maxillary sinus and scattered multiple radiopaque mass inside the lesion. Biopsy was performed under local anesthesia. On microscopic examination, numerous fungal hyphae, which branch at acute angle, were observed. The diagnosis was made as an aspergilloma based on the histopathologic examination.

  12. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  13. Does the urethral angle change with leg position? Implications for urethral-based CT-planned transperineal prostate implants

    International Nuclear Information System (INIS)

    Bednarz, Greg; Ning, Yue; Waterman, Frank M.; Corn, Benjamin W.; Dicker, Adam P.

    1997-01-01

    Purpose: CT based treatment planning for transperineal prostate implants allows for angulation of transperineal needles to avoid the pubic bones by changing the template angle. It requires fluoroscopic guidance and utilizes identification of the urethra by radiopaque markers inside the Foley catheter at the time of the implant. The needle trajectory is relative to the urethral angle as visualized by lateral fluoroscopic views. Patients who have a treatment planning CT in preparation for a transperineal prostate implant are typically scanned in the leg-down/straight position. However, the implant is done in the lithotomy position and changes in the template angle to adapt to the new urethral angle are often required. We have evaluated the relationship between leg position and the position of the prostatic urethra to predict the change in the planned template angle. Material and Methods: To duplicate the lithotomy position a custom designed foot holder was constructed that attached to a flatbed CT scanner. A Foley catheter was inserted with radio-opaque contrast placed in the balloon. Bladder contrast was also utilized. A catheter with 1 cm spaced dummy seeds was placed inside the Foley catheter. A radio-opaque catheter was inserted into the rectum. Fifteen patients had pre-implant scans performed in the leg-down/straight and lithotomy position. The prostate, urethra, bladder and rectum were contoured utilizing a 3D-brachytherapy software system and analyzed. Results: Fourteen of the patients (93%) had changes in urethral angle when evaluated in the lithotomy relative to the led-down/straight position. The mean angle change was - 9.8 degrees (Std. Error 1.47 degrees; p < 0.0001) when in the lithotomy position. The changes were not correlated with prostatic volume or clinical stage. All patients who had urethral angle changes would have required adjustments in the template angle. Conclusions: 1) The objective of treatment planning for prostate implants is to

  14. The Use of Recombinant Human Platelet-Derived Growth Factor for Maxillary Sinus Augmentation.

    Science.gov (United States)

    Kubota, Atsushi; Sarmiento, Hector; Alqahtani, Mohammed Saad; Llobell, Arturo; Fiorellini, Joseph P

    The maxillary sinus augmentation procedure has become a predictable treatment to regenerate bone for implant placement. The purpose of this study was to evaluate the effect of recombinant human platelet-derived growth factor BB (rhPDGF-BB) combined with a deproteinized cancellous bovine bone graft for sinus augmentation. The lateral window approach was used for maxillary sinuses with minimal residual bone. After a healing period of 4 months, dental implants were placed and then restored following a 2-month osseointegration period. The result demonstrated increased bone height and ISQ values and a 100% survival rate. This study indicates that the addition of rhPDGF-BB to deproteinized cancellous bovine bone accelerated the healing period in maxillary sinuses with minimal native bone.

  15. A 2D panoramic surgical stent imaging: Complete arch mandibular implant fixed prosthesis along with bar supported maxillary over denture

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2017-01-01

    Full Text Available Successful rehabilitation of a patient should restore function, esthetic, and speech by prosthesis. Treatment modalities vary from patient to patient. Semi-precision attachments and implants offer several advantages over the traditional approach. The aim and objective of this report was to assess a case of a 55-year-old female patient who had lost all her teeth, except maxillary canines #13 and #23 and with severe bone loss in the mandible. Tooth-supported bar attachment was planned for maxilla, and a total of five dental implants were placed in the mandible using a flapless approach aided by radiographic gutta-percha surgical stents over panoramic two-dimensional imaging. Customized, radiographic stents help for the placement of implant in the view of paralleling and flapless surgery, completely. An immediate loading protocol is adopted as from day of the surgery to 6 weeks along with implant supported full arch fixed dentures after 4 months. The outcome of the treatment was impressive, and the patient gave a positive response with superb esthetics and functions.

  16. A comparative study on the stress distribution around dental implants in three arch form models for replacing six implants using finite element analysis.

    Science.gov (United States)

    Zarei, Maryam; Jahangirnezhad, Mahmoud; Yousefimanesh, Hojatollah; Robati, Maryam; Robati, Hossein

    2018-01-01

    Dental implant is a method to replacement of missing teeth. It is important for replacing the missed anterior teeth. In vitro method is a safe method for evaluation of stress distribution. Finite element analysis as an in vitro method evaluated stress distribution around replacement of six maxillary anterior teeth implants in three models of maxillary arch. In this in vitro study, using ABAQUS software (Simulia Corporation, Vélizy-Villacoublay, France), implant simulation was performed for reconstruction of six maxillary anterior teeth in three models. Two implants were placed on both sides of the canine tooth region (A model); two implants on both sides of the canine tooth region and another on one side of the central incisor region (B model); and two implants on both sides of the canine tooth region and two implants in the central incisor area (C model). All implants evaluated in three arch forms (tapered, ovoid, and square). Data were analyzed by finite analysis software. Von Mises stress by increasing of implant number was reduced. In a comparison of A model in each maxillary arch, the stress created in the cortical and cancellous bones in the square arch was less than ovoid and tapered arches. The stress created in implants and cortical and cancellous bones in C model was less than A and B models. The C model (four-implant) reduced the stress distribution in cortical and cancellous bones, but this pattern must be evaluated according to arch form and cost benefit of patients.

  17. Treatment of Angle Class I Malocclusion with Severe Bimaxillary Protrusion using Miniscrew Implants and Periodontal Ligament Distraction

    Directory of Open Access Journals (Sweden)

    K C Prabhat

    2014-01-01

    Full Text Available Bimaxillary dentoalveolar protrusion is common in Asian population. In this patient with procumbent upper and lower lips, excessive lip strain, proclined and protruded maxillary and mandibular incisors with vertical growth pattern, an acceptable treatment result, was achieved with 4-first-premolar extractions. This case report is presented with the aim, to describe the treatment approach for bimaxillary dentoalveolar protrusion using miniscrew implants for anchorage in upper arch and periodontal ligament distraction for canine retraction in lower arch and then retraction of incisors into the newly formed bone distal to lateral incisor. Treatment was completed in 18 months. The patient profile was improved, with reduction in lip procumbency, decrease in lip eversion and protrusion, and decrease mentalis strain. Dentally, the interincisal angulation improved significantly because both the maxillary and mandibular incisors were uprighted after space closer.

  18. Nasopalatine duct cyst associated with dental implant treatment: A case report

    Directory of Open Access Journals (Sweden)

    Shintaro Sukegawa, DDS, PhD

    2015-09-01

    Full Text Available Maxillary anterior implants are associated with the risk of nasopalatine canal damage. Here we present the case of a 37-year-old man who developed a nasopalatine duct cyst after maxillary implant placement. The patient received an implant 3 months after the extraction of a fractured maxillary right central incisor. At a maintenance visit 9 years after the procedure, he complained of swelling and mild pain in the palatal region of the implant. A panoramic radiograph and computed tomography (CT scan revealed a large, well-circumscribed, periapical radiolucency surrounding the apical portion of the implant and extending to the nasopalatine duct. We removed the entire lesion without removing the implant. Histopathologic examination of the resected specimen revealed a nasopalatine duct cyst. Accidental contact with the nasopalatine canal during implant surgery may have led to the development of the nasopalatine duct cyst. Careful planning using a preoperative CT scan prior to implant placement may prevent such complications.

  19. Anterior maxillary segmental distraction for correction of maxillary hypoplasia and dental crowding in cleft palate patients: a preliminary report.

    Science.gov (United States)

    Wang, X-X; Wang, X; Li, Z-L; Yi, B; Liang, C; Jia, Y-L; Zou, B-S

    2009-12-01

    To evaluate the feasibility of anterior maxillary segmental distraction (AMSD) to correct maxillary hypoplasia and severe dental crowding in cleft lip and palate (CLP) patients, 7 patients (average age 16.4 years) with maxillary hypoplasia, shortened maxillary dental arch length and severe anterior dental crowding secondary to CLP were selected for this study. After anterior maxillary segmental osteotomy, 3 patients were treated using bilateral internal distraction devices, and 4 patients were treated using rigid external distraction devices. Photographs and radiographs were taken to review the improvement in facial profile and occlusion after distraction. An average 10.25 mm anterior maxillary advancement was obtained in all patients after 10-23 days of distraction and 9-16 weeks of consolidation. The sella-nasion-point A (SNA) angle increased from 69.5 degrees to 79.6 degrees. Midface convexity was greatly improved and velopharyngeal competence was preserved. The maxillary dental arch length was greatly increased by 10.1 mm (P<0.01). Dental crowding and malocclusion were corrected by orthodontic treatment. These results show that AMSD can effectively correct the hypoplastic maxilla and severe dental crowding associated with CLP by increasing the midface convexity and dental arch length while preserving velopharyngeal function, and dental crowding can be corrected without requiring tooth extraction.

  20. Effects of labial and lingual retraction and intrusion force on maxillary central incisor with varying collum angles: A three-dimensional finite elemental analysis

    Directory of Open Access Journals (Sweden)

    Sandesh S Pai

    2017-01-01

    Full Text Available Aims: This study aims to analyze the effects of intrusive force, retraction force, and torque control on the maxillary central incisors with varying degrees of collum angle in labial and lingual orthodontic treatment procedures using finite element analysis. Subjects and Methods: Four pairs of three-dimensional finite element models (FEMs representative of maxillary central incisor with periodontal ligament (PDL and alveolar bone were constructed using ANSYS software (version 5.4, ANSYS Inc., Canonsburg, PA, USA. The models with 0°, 5°, 10°, and 15° were created based on crown root angulation. Four models for labial and four models for lingual orthodontic procedure were constructed. Each model was subjected to three forces, i.e., retraction force of 1 N, lingual root torque of −5 × 10−3 N and intrusive force of 0.64 N on crown with labially and lingually positioned brackets. Principal stress and strain, center of rotation and root apex displacement were monitored. Statistical Analysis Used: Not required (FEM study. Results: With the increase in collum angle, the stress-strain distribution in PDL was increased in both labial orthodontics (LaO and lingual orthodontics (LiO. Stress-strain distribution in the PDL with LiO was more in all the models as compared to LaO. There was more of tipping movement as collum angle increased from 0° to 15° in both LaO and LiO. The amount of intrusion reduced as the collum angle increased in both the systems. However, more of intrusion was seen in LaO. With increase in collum angle, the center of rotation moved cervically in both the systems. Conclusions: From the present study, we conclude that as the collum angle increased, the stress-strain distribution increased in LaO and LiO. The center of rotation shifted cervically, and the intrusion decreased when collum angle increased. The values were more marked in LiO.

  1. Evaluation of possible prognostic factors for the success, survival, and failure of dental implants.

    Science.gov (United States)

    Geckili, Onur; Bilhan, Hakan; Geckili, Esma; Cilingir, Altug; Mumcu, Emre; Bural, Canan

    2014-02-01

    To analyze the prognostic factors that are associated with the success, survival, and failure rates of dental implants. Data including implant sizes, insertion time, implant location, and prosthetic treatment of 1656 implants have been collected, and the association of these factors with success, survival, and failure of implants was analyzed. The success rate was lower for short and maxillary implants. The failure rate of maxillary implants exceeded that of mandibular implants, and the failure rate of implants that were placed in the maxillary anterior region was significantly higher than other regions. The failure rates of implants that were placed 5 years ago or more were higher than those that were placed later. Anterior maxilla is more critical for implant loss than other sites. Implants in the anterior mandible show better success compared with other locations, and longer implants show better success rates. The learning curve of the clinician influences survival and success rates of dental implants.

  2. Influence of Abutment Angle on Implant Strain When Supporting a Distal Extension Removable Partial Dental Prosthesis: An In Vitro Study.

    Science.gov (United States)

    Hirata, Kiyotaka; Takahashi, Toshihito; Tomita, Akiko; Gonda, Tomoya; Maeda, Yoshinobu

    This study evaluated the impact of angled abutments on strain in implants supporting a distal extension removable partial denture. An in vitro model of an implant supporting a distal extension removable partial denture was developed. The implant was positioned with a 17- or 30-degree mesial inclination, with either a healing abutment or a corrective multiunit abutment. Levels of strain under load were compared, and the results were compared using t test (P = .05). Correcting angulation with a multiunit angled abutment significantly decreased strain (P abutment. An angled abutment decreased the strain on an inclined implant significantly more than a healing abutment when loaded under a distal extension removable partial denture.

  3. Orthodontic Management of Congenitally Missing Maxillary Lateral Incisors: A Case Report

    OpenAIRE

    Paduano, Sergio; Cioffi, Iacopo; Rongo, Roberto; Cupo, Antonello; Bucci, Rosaria; Valletta, Rosa

    2014-01-01

    This case report describes the orthodontic treatment of a woman, aged 15 years, with permanent dentition, brachyfacial typology, with congenitally missing maxillary lateral incisors. Multibracket straightwire fixed appliance was used to open the space for dental implant placement, and treat the impaired occlusion. The missing lateral incisors were substituted with oral implants.

  4. [Reconstruction of maxillary sinus superior wall fractures with calcium phosphate cement/recombinant human bonemorphogenetic protein 7 compound implanted material in rabbit].

    Science.gov (United States)

    Zhang, Qunhui; Yu, Feng; Zhang, Haoliang; Gong, Huicheng; Lin, Ying

    2015-11-01

    To evaluate the osteogenetic character and repairing maxillary sinus superior wall fractures capability of calcium phosphate cement (CPC) before and after combined with recombinant human bone morphogenetie protein-7(rhBMP-7). A 10 mmX5 mm bone defect in the maxillary sinus superior wall was induced by surgery in all 24 New Zealand white rabbits. These 24 rabbits were randomly divided into two groups. The defects were repaired with CPC group (n = 12) and CPC/rhBMP-7 group (n = 12). The osteogenesis of bone defect was monitored by gro'ss observation, histological examination, observation under scanning electron microscope and measurement of ALP activity at 6 and 12 weeks after the implantation. In group CPC,new bone was found to form slowly and little by little. In group CPC/rhBMP-7, however, new bone was observed to form early and massively. The ALP activity in group CPC showed significant statistical difference with that of group CPC/rhBMP-7 (P < 0.05). The CPC/rhBMP-7 composite has osteoconductibility and osteoinductibility, comparing the use of CPC/rhBMP-7 with CPC for the repair of orbital fracture, the former show obvious advantage repairing ability in maxillary sinus superior wall defect.

  5. Orthodontic Management of Congenitally Missing Maxillary Lateral Incisors: A Case Report

    Directory of Open Access Journals (Sweden)

    Sergio Paduano

    2014-01-01

    Full Text Available This case report describes the orthodontic treatment of a woman, aged 15 years, with permanent dentition, brachyfacial typology, with congenitally missing maxillary lateral incisors. Multibracket straightwire fixed appliance was used to open the space for dental implant placement, and treat the impaired occlusion. The missing lateral incisors were substituted with oral implants.

  6. Expansão rápida da maxila ancorada em implantes: uma nova proposta para expansão ortopédica na dentadura permanente Rapid maxillary expansion anchored by implants: a new proposal to orthopedic expansion in the permanent dentition

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2007-06-01

    Full Text Available OBJETIVO: este trabalho apresenta um método para expansão ortopédica da maxila, na dentadura permanente, utilizando implantes como ancoragem. METODOLOGIA: detalharam-se os procedimentos cirúrgicos e laboratoriais da confecção de um expansor com ancoragem dento-óssea em crânio seco humano. Dois implantes de titânio foram colocados na região anterior do palato, e o parafuso Hyrax adaptado de modo que a expansão ancorou-se nos implantes e nos primeiros molares permanentes. RESULTADOS: o experimento laboratorial em crânio seco mostrou que o procedimento apresenta-se anatômica e operacionalmente viável. Os implantes suportaram a força gerada pela ativação do parafuso expansor, redundando na separação transversal das hemimaxilas. CONCLUSÕES: vislumbra-se que a expansão rápida da maxila ancorada em implantes (ERMAI poderá potencializar a eficiência da expansão ortopédica, assim como reduzir o custo periodontal dos procedimentos convencionais de expansão. Futuros estudos clínicos são necessários para testar essas hipóteses.AIM: This study presents a method for maxillary orthopedic expansion, in the permanent dentition, using implants as anchorage. METHODS: Surgical and laboratorial procedures for the construction of a tooth-bone-borne expansor was detailed in a human dry skull. Two titanium implants were placed in the anterior region of the palate and a Hyrax screw was adapted in a way that the expansion was anchored both on the palatal implants and on permanent first molars. RESULTS: The laboratorial experiment in dry skull showed that the procedure is operationally and anatomically possible. The implants supported the force generated by the expansion screw activation and the maxilla halves were transversally split. CONCLUSIONS: Rapid maxillary expansion anchored on implants can increase the efficiency of orthopedic expansion and decrease the periodontal sequela caused by conventional RME. Further clinical studies are

  7. An analysis of reliability and validity of the papilla index score of implant-supported single crowns of maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2012-01-01

    Objectives: To test the reliability and validity of the papilla index scores of the implant-supported single crowns (ISSCs) of maxillary central incisors. Materials and Methods: Twenty-five patients with 25 ISSCs were included. Two prosthodontists evaluated the papilla index score (PIS) of three...... inter-observer agreement. The PIS score demonstrated significant correlation to the corresponding PP value (rs=.567, p=.000). Conclusions: The feasibility, reliability and validity of the PIS made the parameter useful for quality control of the pri-implant soft tissue of ISSCs....... fill percent (PP) was calculated. The validity of PIS was tested against the corresponding papilla fill percent (PP) by using the Spearman correlation analysis. Results: The intra-observer agreement was >70% in 4/5 and >50% in all observations, the pooled Cohen’s ¿ was 0.64 and 0.70 for two observers...

  8. Morphological study of maxillary canine region based on CT

    International Nuclear Information System (INIS)

    Yamada, Maiko; Takamori, Hitoshi; Ide, Yoshiaki; Yosue, Takashi

    2010-01-01

    The maxilla is generally known as a site where anatomical limitations make it difficult to obtain sufficient bone volume. A large amount of bone exists in the canine region between the anterior margin of the maxillary sinus and the piriform aperture margin. Although this region is crucial for implant treatments, there have not been any reports on morphological studies of the region. In this study, we investigated the morphology of the canine region based on CT, and also the morphology and position of the maxillary sinus located posterior to the canine region. The results were as follows: In the area above the anterior nasal spine, the higher the level, the smaller the mesio-distal length and the bucco-lingual width tended to become. In the area above the anterior nasal spine, the mesio-distal length and the bucco-lingual width tended to be smaller in female patients than in male patients. In the area above the anterior nasal spine, no significant differences in mesio-distal length and bucco-lingual width were observed between dentulous and edentulous jaws. The morphology of the maxillary sinus was mainly of an inverse-trapezoidal, circular, or triangular form. The position of the anterior wall of the maxillary sinus was most frequently found at the site corresponding to the second premolar. Through this study, we have reconfirmed that the canine region is vital for implant treatments in the maxilla. (author)

  9. A 3-year clinical and radiographic study of implants placed simultaneously with maxillary sinus floor augmentations using a new nanocrystalline hydroxyapatite.

    Science.gov (United States)

    Heinemann, F; Mundt, T; Biffar, R; Gedrange, T; Goetz, W

    2009-12-01

    The aims of this case series was to evaluate the success rate of implants and their restorations, the sinus bone graft resorption, and the marginal bone loss around the implants when nanocristalline HA embedded in a silica matrix was exclusively used as grafting material. In 13 partially edentulous patients of a private practice having missing teeth in the posterior maxilla and a subantral bone height between 3 and 7 mm, 19 sinus augmentations (100% Nanobone, Artoss, Rostock, Germany) by the lateral lift technique were performed. The implants (Tiolox/Tiologic Implants, Dentaurum, Ispringen, Germany) were simultaneously placed. After 6 to 9 months 37 implants were restored with fixed dental prostheses. The clinical evaluation included peri-implant parameters, periotest measurements and the restorations. The radiographic bone heights over time were estimated with linear mixed models. The implant success rate was 100% after three years. The periotest values (between -7 and -6) after implant abutment connection indicated a solid osseointegration. The mean rates of the marginal bone loss over the first year were higher (mesial: -0.55, distal: -0.51 mm) than the annual rates thereafter (mesial: -0.09 mm, distal: -0.08 mm). The mean rates of changes in the total bone height were neglectable (<0.2 mm) and not significant. The prosthodontic and esthetic evaluation revealed a successful outcome. Within the limits of this clinical report it may be concluded that maxillary sinus augmentation using 100% nanocristalline HA embedded in a silica matrix to support implants is a reliable procedure.

  10. Narrow- (3.0 mm) Versus Standard-Diameter (4.0 and 4.5 mm) Implants for Splinted Partial Fixed Restoration of Posterior Mandibular and Maxillary Jaws: A 5-Year Retrospective Cohort Study.

    Science.gov (United States)

    Pieri, Francesco; Forlivesi, Caterina; Caselli, Ernesto; Corinaldesi, Giuseppe

    2017-04-01

    Evidence concerning predictability of narrow-diameter implants (NDIs) (3.0 mm) and standard-diameter implants (SDIs) (4.0 to 4.5 mm) supporting fixed partial dentures (FPDs) in posterior mandibular and maxillary jaws. All patients treated with at least two adjacent NDIs or SDIs according to available bone thickness and with a minimum follow-up of 5 years after placement were invited to undergo a clinical and radiologic examination. Outcome measures were implant and FPD failures, biologic and prosthetic complications, and marginal bone loss. A total of 107 out of 127 patients attended the examination: 49 (113 implants) of the NDI group, and 58 (126 implants) of the SDI group. Two NDIs failed in one patient versus four SDIs in four patients (P = 0.37). One FPD failed in the NDI group versus two FPDs in the SDI group (P >0.99). Nine biologic complications occurred in the NDI group and twelve in the SDI group (P = 0.81). Twelve prosthetic complications occurred in the NDI group and only two in the SDI group (P = 0.001). Peri-implant marginal bone loss at 5 years was 0.95 ± 0.84 mm for the NDI group and 1.2 ± 0.86 mm for the SDI group (P = 0.06). Five-year data indicate that FPD treatment in posterior mandibular and maxillary jaws with NDIs was as reliable as with SDIs, although NDIs showed a higher risk of prosthetic complications.

  11. Rehabilitation of Posterior Maxilla with Obturator Supported by Zygomatic Implants

    Directory of Open Access Journals (Sweden)

    Sankalp Mittal

    2018-01-01

    Full Text Available Prosthetic rehabilitation of atrophic maxilla and large maxillary defects can be done successfully by zygomatic implant-supported prosthesis. Zygomatic implants are an avant-garde to complex and invasive-free vascularised osteocutaneous flaps, distraction osteogenesis, and the solution to flap failures. A treated case of tuberculous osteomyelitis, with a class II (Aramany’s classification maxillary defect, reported to oral maxillofacial department, Government Dental College (RUHS-CODS. The defect in this group was unilateral, retaining the anterior teeth. The patient was previously rehabilitated with a removable maxillary obturator. Inadequate retention affected essential functions like speaking, mastication, swallowing, esthetics, and so on due to lack of sufficient supporting tissues. A fixed prosthetic rehabilitation of posterior maxillary defect was done with obturator supported with two single-piece zygomatic implants. At 1-year follow-up, the patient was comfortable with the prosthesis, and no further complaints were recorded.

  12. Five years experience with a new intraoral maxillary distraction device (RID).

    Science.gov (United States)

    Picard, Arnaud; Diner, Patrick A; Galliani, Eva; Tomat, Catherine; Vazquez, Ma rie Paule; Carls, Friedrich P

    2011-10-01

    Maxillary distraction osteogenesis is well established for the treatment of severe retromaxilla. We report our experience since 2004 of the treatment of 19 patients using a new intraoral maxillary distraction device. Maxillary advancement was successful in all patients with mean advancement of 9.6mm (range 4-17) measured at a point in lateral cephalograms. The new device limited surgical exposure and the amount of materials implanted, and improved control in every phase of the distraction. It was psychologically accepted by patients and was more comfortable than existing devices. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

    International Nuclear Information System (INIS)

    Darsey, Drew M.; English, Jeryl D.; Ellis, Randy K.; Akyalcin, Sercan; Kau, Chung H

    2012-01-01

    The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93 mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

  14. Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

    Energy Technology Data Exchange (ETDEWEB)

    Darsey, Drew M.; English, Jeryl D.; Ellis, Randy K.; Akyalcin, Sercan [School of Dentistry, University of Texas Health Science Center at Houston, Houston (United States); Kau, Chung H [School of Dentistry, University of Alabama at Birmingham, Birmingham (United States)

    2012-06-15

    The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93 mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

  15. Impacted maxillary canines and root resorption of adjacent teeth: A retrospective observational study.

    Science.gov (United States)

    Guarnieri, R; Cavallini, C; Vernucci, R; Vichi, M; Leonardi, R; Barbato, E

    2016-11-01

    The prevalence of impacted maxillary canine is reported to be between 1% and 3%. The lack of monitoring and the delay in the treatment of the impacted canine can cause different complications such as: displacement of adjacent teeth, loss of vitality of neighbouring teeth, shortening of the dental arch, follicular cysts, canine ankylosis, recurrent infections, recurrent pain, internal resorption of the canine and the adjacent teeth, external resorption of the canine and the adjacent teeth, combination of these factors. An appropriate diagnosis, accurate predictive analysis and early intervention are likely to prevent such undesirable effects. The objective is to evaluate, by means of a retrospective observational study, the possibility of carrying out a predictive analysis of root resorption adjacent to the impacted canines by means of orthopantomographs, so as to limit the prescription of additional 3D radiography. 120 subjects with unilateral or bilateral maxillary impacted canine were examined and 50 patients with 69 impacted maxillary canine (22 male, 28 female; mean age: 11.7 years) satisfied the inclusion criteria of the study. These patients were subjected to a basic clinical and radiographic investigation (orthopantomographs and computerized tomography). All panoramic films were viewed under standardized conditions for the evaluation of two main variables: maxillary canine angulations (a, b, g angles) and the overlapping between the impacted teeth and the lateral incisor (Analysis of Lindauer). Binary logistic regression was used to estimate the likelihood of resorbed lateral incisors depending on sector location and angle measurements. Results indicated that b angle has the greatest influence on the prediction of root resorption (predictive value of b angle = 76%). If β angle <18° and Lindauer = I, the probability of resorption is 0.06. Evaluation of b angle and superimposition lateral incisor/impacted canine analysed on orthopantomographs could be one of

  16. DIRECT USAGE OF MINISCREW ANCHORAGE TO INTRUDE OVERERUPTED MAXILLARY POSTERIOR TEETH BEFORE PROSTHODONTIC PREPARATION:A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Yasemin Bahar Acar

    2016-01-01

    Full Text Available Overeruption of maxillary molars due loss of opposing teeth creates occlusal and functional interferences. Before reconstruction can be initiated, intrusion of overerupted molars becomes essential. This report illustrates treatment of overerupted maxillary premolar and molar via direct use of miniscrew anchorage. A 24-year old female had lost first and second left mandibular molars due to pulpal necrotizing agents, resulting with a large alveolar bone defect and overerupted maxillary premolar and molar. She had a history of unsuccessful alveolar distraction of mandibular left premolars to increase the alveolar bone height prior to implant placement. Patient was satisfied with her smile and refused comprehensive orthodontic treatment. Maxillary premolar and molar were intruded segmentally for 4mm in 8 months, using a combination of a mini-implant and partialfixed edgewise appliances. Biological responses of teeth and surrounding bony structures to intrusion appeared normal and acceptable in radiographic and clinical examination.

  17. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

    Science.gov (United States)

    Vercellotti, Tomaso; Stacchi, Claudio; Russo, Crescenzo; Rebaudi, Alberto; Vincenzi, Giampaolo; Pratella, Umberto; Baldi, Domenico; Mozzati, Marco; Monagheddu, Chiara; Sentineri, Rosario; Cuneo, Tommaso; Di Alberti, Luca; Carossa, Stefano; Schierano, Gianmario

    2014-01-01

    This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

  18. Management of compromised anterior maxillary edentulous arch with symphyseal bone graft

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2018-01-01

    Full Text Available Achieving optimal aesthetics, function and phonetics with implant-supported restorations depends largely on the amount of bone present at the site where implant has to be placed. Sometimes, patient reports with compromised conditions which makes the implant placement difficult. Today, reconstruction procedures such as autogenous bone graft and guided bone regeneration make the implant placement possible in different ridge deficient cases. This case report describes step-by-step procedure of restoring the missing maxillary right central incisor with implant-supported prostheses. In missing left central incisor region, the alveolar bony defect was corrected by autogenous bone graft obtained from symphysis region, for restoration with implant prostheses.

  19. Detection of Second Mesiobuccal Canals in Maxillary First Molars Using a New Angle of Cone Beam Computed Tomography.

    Science.gov (United States)

    Aktan, Ali Murat; Yildirim, Cihan; Culha, Emre; Demir, Erhan; Ertugrul Ciftci, Mehmet

    2016-10-01

    The localization of the additional canal orifice is one of the primary factors influencing the success of endodontic treatment. To deal with this problem, several techniques that each have their own advantages and disadvantages have been discussed in the literature. The aim of the present in vitro study was to review a new approach to localizing second mesiobuccal (MB2) canals in maxillary first molars using cone beam computed tomography (CBCT). The CBCT scans of 296 patients who were referred to the department of dentomaxillofacial radiology were included in the study. The presence of MB2 canals, the angle formed by the mesiobuccal, distobuccal, and palatal root canal orifices (∠MDP), and the angle formed by the mesiobuccal, distobuccal, and MB2 canal orifices (∠MDMB2) were evaluated on the axial section. Pearson correlation and multiple linear regression methods were used for all predictions. All of the analyses were performed using SPSS for windows version 22.0. A two-sided P value values, it was shown that the ∠MDMB2 increased by 0.420 degrees when the ∠MDP increased by 1 degree. If the ∠MDP was greater than 90.95 degrees, there was a 78% probability that MB2 canals could be found. The determination of the presence of MB2 in the maxillary first molars may be carried out using CBCT scans. If the ∠MDP was 91 degrees or greater, there was considered to be a higher probability that MB2 canals would be found in the endodontic cavity. Due to the positive correlation between the ∠MDP and the ∠MDMB2, the localization of MB2 canals may be easily performed in relation to the main MB canal.

  20. Classification of alveolar bone destruction patterns on maxillary ...

    African Journals Online (AJOL)

    Objective: The defective diagnosis of alveolar structures is one of most serious handicaps when assessing available periodontal treatment options for the prevention of tooth loss. The aim of this research was to classify alveolar bone defects in the maxillary molar region which is a challenging area for dental implant ...

  1. Influence of custom-made implant designs on the biomechanical performance for the case of immediate post-extraction placement in the maxillary esthetic zone: a finite element analysis.

    Science.gov (United States)

    Chen, Jianyu; Zhang, Zhiguang; Chen, Xianshuai; Zhang, Xiao

    2017-05-01

    Due to the increasing adoption of immediate implantation strategies and the rapid development of the computer aided design/computer aided manufacturing technology, a therapeutic concept based on patient-specific implant dentistry has recently been reintroduced by many researchers. However, little information is available on the designs of custom-made dental implant systems, especially their biomechanical behavior. The influence of the custom-made implant designs on the biomechanical performance for both an immediate and a delayed loading protocol in the maxillary esthetic zone was evaluated by means of the finite element (FE) method. FE models of three dental implants were considered: a state of the art cylindrical implant and two custom-made implants designed by reverse engineering technology, namely a root-analogue implant and a root-analogue threaded implant. The von Mises stress distributions and micro-motions around the bone-implant interfaces were calculated using ANSYS software. In a comparison of the three implant designs for both loading protocols, a favorable biomechanical performance was observed for the use of root-analogue threaded implant which approximated the geometry of natural anterior tooth and maintained the original long-axis. The results indicated that bone-implant interfacial micro-motion was reduced and a favorable stress distribution after osseointegration was achieved.

  2. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments.

    Science.gov (United States)

    Santing, Hendrik Jacob; Meijer, Henny J A; Raghoebar, Gerry M; Özcan, Mutlu

    2012-12-01

    Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. The objectives of this study were to evaluate the fracture strength of implant-supported composite resin crowns on PEEK and solid titanium temporary abutments, and to analyze the failure types. Three types of provisional abutments, RN synOcta Temporary Meso Abutment (PEEK; Straumann), RN synOcta Titanium Post for Temporary Restorations (Straumann), and Temporary Abutment Engaging NobRplRP (Nobel Biocare) were used, and provisional screw-retained crowns using composite resin (Solidex) were fabricated for four different locations in the maxilla. The specimens were tested in a universal testing machine at a crosshead speed of 1 mm/minute until fracture occurred. The failure types were analyzed and further categorized as irreparable (Type 1) or reparable (Type 2). No significant difference was found between different abutment types. Only for the position of the maxillary central incisor, composite resin crowns on PEEK temporary abutments showed significantly lower (p Provisional crowns on PEEK abutments showed similar fracture strength as titanium temporary abutments except for central incisors. Maxillary right central incisor composite resin crowns on PEEK temporary abutments fractured below the mean anterior masticatory loading forces reported to be approximately 206 N. © 2010 Wiley Periodicals, Inc.

  3. Dental Implant Placement with Simultaneous Anterior Maxillary Reconstruction with Block and Particulate Fresh Frozen Allograft Bone: A Case Report with 24-Month Follow-Up Data

    Directory of Open Access Journals (Sweden)

    J. S. Vieira

    2017-01-01

    Full Text Available Fresh frozen allograft bone is routinely used in orthopedic surgery for the reconstruction of large bone defects, and its use in oral and maxillofacial surgery is increasing. The purpose of this case was to demonstrate the installation of dental implants and the use of fresh frozen bone for reconstruction of anterior maxilla in the same surgery. This case report presents the insertion of dental implants followed immediately by a placement of fresh frozen allograft in block and particle for a reconstruction of atrophic anterior maxillary in the same surgery. Ten months subsequent to this procedure, provisional fixed prosthesis was installed on the implants. Four months later (postoperative month 14, the final fixed prosthesis was installed and the clinical success was observed. The insertion of dental implants followed immediately by a placement of fresh frozen allograft is a safe and efficient process that results in the successful return of dental function and aesthetic rehabilitation for the patient.

  4. A 3-year prospective clinical study of telescopic crown, bar, and locator attachments for removable four implant-supported maxillary overdentures.

    Science.gov (United States)

    Zou, Duohong; Wu, Yiqun; Huang, Wei; Wang, Feng; Wang, Shen; Zhang, Zhiyong; Zhang, Zhiyuan

    2013-01-01

    To evaluate telescopic crown (TC), bar, and locator attachments used in removable four implant-supported overdentures for patients with edentulous maxillae. A total of 30 maxillary edentulous patients were enrolled in a 3-year prospective study. Ten patients (group A) were treated with overdentures supported by TCs, 10 patients (group B) with overdentures supported by bar attachments, and 10 patients (group C) with overdentures supported by locator attachments. A total of 120 implants were used to restore oral function. During the 3-year follow-up period, implant survival and success rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction were evaluated. All 30 patients were available for the 3-year follow-up and exhibited 100% implant survival and success rates. Peri-implant marginal bone resorption was not statistically significant for the three groups. There were lower plaque, bleeding, gingiva, and calculus indices in group C compared with groups A and B. The number of prosthodontic maintenance visits revealed eight complications in the TC group, seven complications in the bar group, and four complications in the locator group. However, there were no differences in the clinical effects of the overdentures in the three groups. Within the limits of this prospective study, it was concluded that the locator system produced superior clinical results compared with the TC and bar attachments in terms of peri-implant hygiene parameters, the frequency of prosthodontic maintenance measures, cost, and ease of denture preparation. However, longer-term prospective studies are required to confirm these results.

  5. Comparative study of different osteotomy modalities in maxillary distraction osteogenesis for cleft lip and palate.

    Science.gov (United States)

    Yu, Hongbo; Wang, Xudong; Fang, Bing; Shen, Steve Guofang

    2012-11-01

    Conventional maxillary distraction osteogenesis and anterior maxillary segmental distraction were applied in the treatment of severe maxillary hypoplasia secondary to cleft clip and palate. The aim of the present study was to compare the difference between these 2 osteotomy modalities used for rigid external distraction. Ten patients with severe maxillary hypoplasia secondary to CLP were enrolled in our study. They were randomly divided into 2 groups. Conventional maxillary distraction osteogenesis was performed in 5 patients and anterior maxillary segmental distraction in 5 patients. The preoperative and postoperative lateral cephalograms were compared, and cephalometric analysis was performed. The independent sample t test was used to evaluate the differences between the 2 groups. All patients healed uneventfully, and the maxillae moved forward satisfactorily. The sella-nasion-point A angles, nasion-point A-Frankfort horizontal plane angles, overjets, and 0-meridian to subnasale distances had increased significantly after distraction osteogenesis. Significant differences were found in the changes in palatal length between the 2 groups (P maxillary segmental distraction group. No significant difference in the changes in palatopharyngeal depth or soft palatal length was found. With the ability of increasing the palatal and arch length, avoiding changes in palatopharyngeal depth, and preserving palatopharyngeal closure function, anterior maxillary segmental distraction has great value in the treatment of maxillary hypoplasia secondary to CLP. It is a promising and valuable technique in this potentially complicated procedure. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Sinus lifting before Le Fort I maxillary osteotomy: a suitable method for oral rehabilitation of edentulous patients with skelettal class-III conditions: review of the literature and report of a case

    Directory of Open Access Journals (Sweden)

    Meyer Ulrich

    2007-01-01

    Full Text Available Abstract Background Functional rehabilitation of patients afflicted with severe mandibular and maxillary alveolar atrophy might be challenging especially in malformed patients. Methods Treatment planning using sinus lifting and implant placement before Le Fort I maxillary osteotomy in a patient with severe mandibular and posterior maxillary alveolar atrophy and skelettal class-III conditions due to cleft palate are described. Results A full functional and esthetic rehabilitation of the patient was achieved by a stepwise surgical approach performed through sinus lifting as the primary approach followed by implant placement and subsequent Le Fort I maxillary osteotomy to correct the maxillo-mandibular relation. Conclusion Stabilisation of the maxillary complex by a sinus lifting procedure in combination with computer aided implant placement as preorthodontic planning procedure before Le Fort I maxillary osteotomy seems to be suitable in order to allow ideal oral rehabilitation especially in malformed patients.

  7. In situ beam angle measurement in a multi-wafer high current ion implanter

    International Nuclear Information System (INIS)

    Freer, B.S.; Reece, R.N.; Graf, M.A.; Parrill, T.; Polner, D.

    2005-01-01

    Direct, in situ measurement of the average angle and angular content of an ion beam in a multi-wafer ion implanter is reported for the first time. A new type of structure and method are described. The structures are located on the spinning disk, allowing precise angular alignment to the wafers. Current that passes through the structures is known to be within a range of angles and is detected behind the disk. By varying the angle of the disk around two axes, beam current versus angle is mapped and the average angle and angular spread are calculated. The average angle measured in this way is found to be consistent with that obtained by other techniques, including beam centroid offset and wafer channeling methods. Average angle of low energy beams, for which it is difficult to use other direct methods, is explored. A 'pencil beam' system is shown to give average angle repeatability of 0.13 deg. (1σ) or less, for two low energy beams under normal tuning variations, even though no effort was made to control the angle

  8. The Palatal Window for Treating an Incompletely Augmented Maxillary Sinus.

    Science.gov (United States)

    Florio, Salvatore; Suzuki, Takanori; Cho, Sang-Choon

    2017-04-01

    Maxillary sinus augmentation through a lateral window is reported as one of the most predictable bone augmentation procedures before implant placement. The elevation of the membrane represents a delicate and crucial step that allows the creation of the space for the bone graft material. If the elevation is not completed, the regenerated bone might be inadequate for the implant placement. In this case, a new intervention will be necessary to complete the bone augmentation. Reaccessing from a lateral window, however, would be challenging due to thickness of the buccal boney wall because of the first grafting procedure; therefore, a different approach has to be used. The aim of this case report is to present the palatal window technique for treating incompletely augmented maxillary sinus. The detailed step-by-step diagnostic and surgical procedures are described, and the advantages and limitations of the technique are discussed through a review of the literature.

  9. Finite Element Analysis of the Effect of Superstructure Materials and Loading Angle on Stress Distribution around the Implant

    Directory of Open Access Journals (Sweden)

    Jafari K

    2014-12-01

    Full Text Available Statement of Problem: A general process in implant design is to determine the reason of possible problems and to find the relevant solutions. The success of the implant depends on the control technique of implant biomechanical conditions. Objectives: The goal of this study was to evaluate the influence of both abutment and framework materials on the stress of the bone around the implant by using threedimensional finite element analysis. Materials and Methods: A three-dimensional model of a patient’s premaxillary bone was fabricated using Cone Beam Computed Tomography (CBCT. Then, three types of abutment from gold, nickel-chromium and zirconia and also three types of crown frame from silver-palladium, nickel-chromium and zirconia were designed. Finally, a 178 N force at angles of zero, 30 and 45 degrees was exerted on the implant axis and the maximum stress and strain in the trabecular, cortical bones and cement was calculated. Results: With changes of the materials and mechanical properties of abutment and frame, little difference was observed in the level and distribution pattern of stress. The stress level was increased with the rise in the angle of pressure exertion. The highest stress concentration was related to the force at the angle of 45 degrees. The results of the cement analysis proved an inverse relationship between the rate of elastic modulus of the frame material and that of the maximum stress in the cement. Conclusions: The impact of the angle at which the force was applied was more significant in stress distribution than that of abutment and framework core materials.

  10. Immediate implant placement and provisionalization with simultaneous guided bone regeneration in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Chih-Long Chen

    2011-03-01

    Full Text Available The procedure for immediate implant placement and provisionalization is time-saving, possibly with only one surgical intervention required, although allowing maximal preservation of peri-implant tissues. In this case, we extracted a fractured maxillary right central incisor of a 46-year-old woman with high esthetic expectations, and a transmucosal implant was immediately installed. Simultaneous guided bone regeneration was performed to correct the defects at the facial side of the socket and augment the alveolar ridge horizontally. Primary stability of the implant body and wound closure without tension were confirmed. Connection of a 15° angled abutment and fabrication of a provisional acrylic resin crown without occlusal contact were also completed in the same appointment. After intensive follow-up and soft-tissue molding for 6 months, the customized zirconia abutment and all-ceramic crown were definitively fabricated. During the 18-month follow-up period, the patient was satisfied with the esthetic and functional results.

  11. CLINICAL USE OF MODERN FLUOROQUINOLONES IN DENTAL IMPLANTATION AND MAXILLARY SINUS LIFTING

    Directory of Open Access Journals (Sweden)

    S.A. Novikov

    2009-03-01

    Full Text Available New fluoroquinolones like levofloxacine, with broad-spectrum of effect which is also active against anaerobic bacteria, is a prospective drug for the prevention of the inflammatory complications in implant dentistry and maxillary sinus augmentation. 34 patients have been selected for this study, including 16 women and 18 men aged 18-65. All the patients have been classified into the main and control groups. Patiens of the first group have been prescribed 500 mg of levofloxacine before and after the operation two times a day for 10 days. Patients of the control group have been treated with amocxicilline. In the control group, which has used amoxicilline, Streptococcus sanguis, Streptococcus salivarius and anaerobic bacteria have been identified. The amount of Prevotella intermedia is insignificant. The same picture has been found with Fusobacterium spp. The rate of Actinomyces spp. was insignificant over the whole period of study. Patients of the experimental group had a slightly different distribution of bacteria. On the 10th day after the operation in the main patient group no periodontal pathogenesis, which may cause inflammatory complications have been identified. During the early post-operative period no significant differences have been observed among the patients of both groups.

  12. Changes in resonance frequency analysis assessed by Osstell mentor during osseointegration: comparison between immediately loaded implants and control implants without load

    Directory of Open Access Journals (Sweden)

    M. González-Jaranay

    2014-10-01

    Full Text Available Aim: The aim of this prospective clinical study was to evaluate the changes in resonance frequency analysis (RFA, assessed by Osstell Mentor, obtaining information on the implant stability quotient (ISQ during implants tissue integration for immediately loaded and non-loaded control implants. Materials and methods: A total of 40 implants, 20 implants with no immediate loading (control and 20 immediately loaded implants (test, were placed in 15 patients. ISQ implants was evaluated at baseline and at 6 and 8 weeks. Provisional crowns were removed at 8 weeks, when the definitive restoration was placed. Data of control and test implants and maxillary and mandibular areas were statistically compared. Results: At 8 weeks, all implants were integrated and there were no major postoperative complications. A statistically significant difference was found only at baseline between test and control maxillary implants (p=0.009 but not at 6 or 8 weeks (p>0.05. Conclusion: Immediate loading procedures may be applied with primary stability ISQ values >60 and inserted with a force of ≥30 N. The Osstell Mentor RFA may offer an objective method to determine when implant stability is adequate for immediate loading.

  13. Distraction Osteogenesis Maxillary Expansion (DOME) for Adult Obstructive Sleep Apnea Patients with High Arched Palate.

    Science.gov (United States)

    Liu, Stanley Yung-Chuan; Guilleminault, Christian; Huon, Leh-Kiong; Yoon, Audrey

    2017-08-01

    A narrow maxilla with high arched palate characterizes a phenotype of obstructive sleep apnea (OSA) patients that is associated with increased nasal resistance and posterior tongue displacement. Current maxillary expansion techniques for adults are designed to correct dentofacial deformity. We describe distraction osteogenesis maxillary expansion (DOME) tailored to adult patients with OSA with narrow nasal floor and high arched palate without soft tissue redundancy. DOME is performed with placement of maxillary expanders secured by mini-implants along the midpalatal suture. This minimizes the maxillary osteotomies necessary to re-create sutural separation for reliable expansion at the nasal floor and palatal vault. We report the safety and efficacy profile of the first 20 patients at Stanford who underwent DOME.

  14. Maxillary sinus augmentation using sinus membrane elevation without grafts - A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rakshith Hegde

    2016-01-01

    Full Text Available Implants have a predictable outcome and are the foremost treatment modality for prosthetic rehabilitation of edentulous patients. Due to loss of bone after extraction and pneumatization of maxillary sinus, there is insufficient bone volume for implant placement. The direct maxillary sinus lift procedure has been performed with different grafting materials (autogenous bone grafts, alloplasts, allografts, and xenografts and without grafting material, having new bone formation around the implant. There is no evidence to prove the need for grafting material in all direct sinus lift procedures, hence the need for this review. Previous meta-analysis showed that survival rates of implants placed in grafted maxillary sinuses had similar survival rates whether autogenous, allogenous, or alloplastic grafts were used. This paper aims to review scientific data on the direct sinus elevation technique without use of any grafting material, volume of new bone formed, and also mechanism behind this technique. Articles were searched from 1997 to October 2014 in PubMed, Google Scholar, and Cochrane CENTRAL. The study eligibility criteria were (1 direct sinus lift procedure without any graft material during implant placement and (2 human or animal studies with a minimum follow-up of 6 months or more. Two authors independently scrutinized the literature and if any controversy was raised, third author's opinion was sought to arrive at a mutual consensus for including the study in the review. Due to the heterogeneity across all studies in all study designs, the data were not pooled and a meta-analysis was not performed. Taking into consideration all factors reviewed in this regard along with the outcomes, the direct sinus lift technique without grafting can be suggested as a viable treatment option keeping in mind the limitations involved. The average bone gain was seen across all studies ranging from 2.37 to 10 mm and with an implant survival rate ranging from 79

  15. Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

    Science.gov (United States)

    Ebadian, Behnaz; Rismanchian, Mansor; Dastgheib, Badrosadat; Bajoghli, Farshad

    2015-01-01

    Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P impression materials (P impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings.

  16. Electroconvulsive therapy after maxillofacial metallic implants.

    Science.gov (United States)

    Freeman, G Mark; Perry, Matthew T; Manatt, George S; Cristancho, Pilar

    2014-03-01

    A growing body of literature suggests that electroconvulsive therapy (ECT) can be safely utilized in patients with craniofacial metallic implants. Here we provide radiographic images and the clinical course of a 49-year-old woman with both maxillary and mandibular metallic implants who safely received ECT.

  17. Bone density around the fixture after function of implant molar prosthesis using CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jae Hyun; Hwang, In Taik; Jung, Byung Hyun; Kim, Jae Duk; Kang, Dong Wan [School of Dentistry, Oral Biology Research Institute, Chosun University, Gwangju (Korea, Republic of)

    2010-03-15

    The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant 2.0TM, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

  18. Investigation into the surface of implanted monocrystalline silicon with the aid of wetting angle

    International Nuclear Information System (INIS)

    Lebedeva, N.N.; Bakovets, V.V.; Sedymova, E.A.; Pridachin, N.B.

    1986-01-01

    The dependence of silicon wetting margical angle on its irradiation dose by ions of electrically active and neutral materials is studied. It has been found that the system of immiscible liquids - ether and water can be successfully used for studying the silicon ion implantation effect on its water wetting. Changing of implanted silicon wetting is bound up with the increase of the defects presence level of surface layers. The specimens annealing reestablishes silicon wetting up to parameters characteristic of non irradiated specimens. The most effective annealing region is within the 550-700 deg C range. The implanted silicon wetting by melts at increased temperatures can be employed for studying kinetics and defect annealing mechanism

  19. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma

    OpenAIRE

    Lee, Geun Young; Lee, Chong Eun; Lee, Kyoo Won; Seo, Sam

    2017-01-01

    AIM: To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG). METHODS: In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP) values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. RESULTS...

  20. Alveolar ridge and maxillary sinus augmentation using rhBMP-2: a systematic review.

    Science.gov (United States)

    Freitas, Rubens Moreno de; Spin-Neto, Rubens; Marcantonio Junior, Elcio; Pereira, Luís Antônio Violin Dias; Wikesjö, Ulf M E; Susin, Cristiano

    2015-01-01

    The aim of this systematic review was to evaluate clinical and safety data for recombinant human bone morphogenetic protein-2 (rhBMP-2) in an absorbable collagen sponge (ACS) carrier when used for alveolar ridge/maxillary sinus augmentation in humans. Clinical studies/case series published 1980 through June 2012 using rhBMP-2/ACS were searched. Studies meeting the following criteria were considered eligible for inclusion: >10 subjects at baseline and maxillary sinus or alveolar ridge augmentation not concomitant with implant placement. Seven of 69 publications were eligible for review. rhBMP-2/ACS yielded clinically meaningful bone formation for maxillary sinus augmentation that would allow placement of regular dental implants without consistent differences between rhBMP-2 concentrations. Nevertheless, the statistical analysis showed that sinus augmentation following autogenous bone graft was significantly greater (mean bone height: 1.6 mm, 95% CI: 0.5-2.7 mm) than for rhBMP-2/ACS (rhBMP-2 at 1.5 mg/mL). In extraction sockets, rhBMP-2/ACS maintained alveolar ridge height while enhancing alveolar ridge width. Safety reports did not represent concerns for the proposed indications. rhBMP-2/ACS appears a promising alternative to autogenous bone grafts for alveolar ridge/maxillary sinus augmentation; dose and carrier optimization may expand its efficacy, use, and clinical application. © 2013 Wiley Periodicals, Inc.

  1. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    Science.gov (United States)

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  2. Prosthodontic maintenance of overdentures on zirconia implants: 1-year results of a randomized controlled trial.

    Science.gov (United States)

    Osman, Reham B; Ma, Sunyoung

    2014-01-01

    The purpose of this study was to determine the prosthodontic outcomes of one-piece zirconia implants and their attachment systems in edentulous participants with maxillary and mandibular overdentures after 1 year of a randomized controlled trial. Random allocation of 24 edentulous participants (age range: 45 to 86 years) into titanium (control) or zirconia (test) groups using onepiece implants and a planned unsplinted prosthodontic design was performed. Four maxillary implants (one midpalatal; three anterior crestal) and three mandibular implants (one midsymphyseal; two bilateral distal) were conventionally loaded with the overdentures. Similar attachment systems were used throughout: ball abutment-type patrices (diameter: 2.25 to 3.1 mm as part of the one-piece implants) and custommade plastic matrices (with or without metal housings depending on the patrix size). Prosthodontic outcomes were documented during the first year of the clinical trial. Following three deaths and two dropouts, there were 19 participants who were available at the 1-year recall. Of these participants, 3 had early maxillary implant failure and had to be converted to conventional maxillary complete dentures opposing mandibular implant overdentures. There were 79 maintenance events, 34 in the titanium (control) group and 45 in the zirconia (test) group. Patrix loss occurred as a result of three zirconia implant fractures (one mandibular and two crestal maxillary implants). Maintenance events were principally the replacement of matrices and overdenture fracture. Although relines and replacement overdentures also occurred, overall there were no significant differences in prosthodontic maintenance between the control and test groups. A six-field prosthodontic-success analysis table showed no statistically significant difference between the two groups; however, 50% of participants in each group were allocated to the retreatment (repair) field, which produced a low prosthodontic success rate

  3. Long-term retrospective study of implants placed after sinus floor augmentation with fresh-frozen homologous block

    Directory of Open Access Journals (Sweden)

    Livingstom Rubens Sousa Rocha

    2017-01-01

    Full Text Available Aim: The aim of this study was to analyze and follow-up implants placed in the posterior maxillary regions previously grafted with homologous bone. Materials and Methods: Forty-one grafts with homologous bone blocks were performed in maxillary sinuses, and 121 implants were placed in premolar and molar regions approximately 6 months after the grafts. Patients were followed up for periods varying from 12 to 124 months after rehabilitation. Results: The results showed two implant failures, for a 98.3% success rate during the follow-up period. Discussion: The implants placed had an average torque of 40 N-cm, regardless of the, design, diameter, and length of the implants used. Conclusion: After following up on the implants placed in this study, we concluded that those placed in regions of the maxillary sinuses previously grafted with homologous bone blocks had high long-term success rates and met the functional masticatory requirements.

  4. Three-dimensional topography of the gingival line of young adult maxillary teeth: curve averaging using reverse-engineering methods.

    Science.gov (United States)

    Park, Young-Seok; Chang, Mi-Sook; Lee, Seung-Pyo

    2011-01-01

    This study attempted to establish three-dimensional average curves of the gingival line of maxillary teeth using reconstructed virtual models to utilize as guides for dental implant restorations. Virtual models from 100 full-mouth dental stone cast sets were prepared with a three-dimensional scanner and special reconstruction software. Marginal gingival lines were defined by transforming the boundary points to the NURBS (nonuniform rational B-spline) curve. Using an iterative closest point algorithm, the sample models were aligned and the gingival curves were isolated. Each curve was tessellated by 200 points using a uniform interval. The 200 tessellated points of each sample model were averaged according to the index of each model. In a pilot experiment, regression and fitting analysis of one obtained average curve was performed to depict it as mathematical formulae. The three-dimensional average curves of six maxillary anterior teeth, two maxillary right premolars, and a maxillary right first molar were obtained, and their dimensions were measured. Average curves of the gingival lines of young people were investigated. It is proposed that dentists apply these data to implant platforms or abutment designs to achieve ideal esthetics. The curves obtained in the present study may be incorporated as a basis for implant component design to improve the biologic nature and related esthetics of restorations.

  5. Zygomatic bone graft for oral-antral communication closure and implant placement.

    Science.gov (United States)

    Peñarrocha-Diago, Miguel; García, Berta; Gomez, Dolores; Balaguer, José

    2007-01-01

    The roots of molar and premolar maxillary teeth are often very close to the floor of the maxillary sinus. As a result, extraction of these teeth can leave an oral-antral communication or lead to a fistula that requires treatment. A woman with an oral-antral communication secondary to extraction of a maxillary molar is presented. The communication was closed by means of a bone graft harvested from the wall of the sinus (zygomatic bone). After 3 months, 2 dental implants were placed, one in the pterygoid area and the other with parasinusal angulation. Rehabilitation followed in the form of a screw-retained, fixed prosthesis 3 months after implant placement. There have been no complications after 1 year of follow-up. This surgical technique allowed closure of an oral-antral communication produced by molar extraction through placement of a zygomatic bone graft and subsequent placement of 2 dental implants.

  6. Pharyngeal airway changes associated with maxillary distraction osteogenesis in adult cleft lip and palate patients.

    Science.gov (United States)

    Aksu, Muge; Taner, Tülin; Sahin-Veske, Pınar; Kocadereli, Ilken; Konas, Ersoy; Mavili, Mehmet Emin

    2012-02-01

    To investigate 1) the changes in pharyngeal airway sizes associated with maxillary distraction osteogenesis and 2) the correlations between maxillary skeletal variables and the pharyngeal airway in adult patients with cleft lip and palate. The study was carried out in 14 adult subjects with cleft lip and palate. Predistraction records were taken at a mean age of 22.7 ± 4.6 years. All patients had placement of a rigid external distraction device (RED I; KLS Martin, Tuttlingen, Germany) after Le Fort I osteotomy. Lateral cephalograms were assessed before surgery and at short-term follow-up (8.0 ± 6.4 months). The cephalometric skeletal and pharyngeal airway variables were statistically evaluated by use of the Wilcoxon signed-rank test. Spearman ρ correlation was performed to check the correlations between maxillary skeletal and pharyngeal variables. The maxillary movement was 8.7 mm (P maxillary depth angle (+7.9°) and effective maxillary length (9.4 mm) increased significantly (P distraction, whereas the palatal plane angle remained unchanged. Anterior nasal spine (8.2 mm) and Posterior nasal spine (6.9 mm) moved anteriorly. The overjet increased (9.5 mm) significantly (P maxillary movement. PNS changes showed the highest correlation with posterior airway changes. The significant anterior movement of the maxilla resulted in significant increases in posterior, superoposterior, and middle airway spaces. The posterior airway space showed the highest significant positive correlation with the movement of PNS. The posterior and superoposterior airway spaces also showed significant positive correlations with the maxillary skeletal variables. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Long-term results of surgically-assisted maxillary protraction.

    Science.gov (United States)

    Nevzatoğlu, Sirin; Küçükkeleş, Nazan

    2014-05-01

    The long-term treatment results of surgically-assisted facemask therapy were assessed by a comparison of the immediate protraction effects with those seen at five years review. Nine patients treated with a corticotomy-assisted maxillary protraction protocol were recalled five years following protraction. Cephalometric films taken before treatment (T0), immediately after maxillary protraction (T1) and five years after treatment (T2) were compared. The short-term results of surgically-assisted facemask therapy showed significant skeletal and soft tissue changes. After five years, the profile and dental relationships were well maintained and a cephalometric analysis revealed a stable vertical increase but only partially maintained soft tissue changes with loss of sagittal advancement. There was significant upper incisor proclination providing dental camouflage. Patients who are treated with corticotomy-assisted maxillary advancement should be very carefully selected. Assessment criteria include a low mandibular plane angle Class III patients who have severe maxillary retrognathism unable to be treated by conventional orthopaedic correction alone; patients who have almost completed growth and missed the chance of earlier orthopaedic correction, as well as patients who are not willing to accept bimaxillary orthognathic surgery, may be successfully treated.

  8. Partitioning the components of maxillary tooth displacement by the comparison of data from three cephalometric superimpositions.

    Science.gov (United States)

    Baumrind, S; Ben-Bassat, Y; Bravo, L A; Curry, S; Korn, E L

    1996-01-01

    Using roentgenographic cephalograms from a sample of subjects with metallic implants, appropriately superimposed tracings were used to distinguish developmental and treatment-associated displacements of the maxillary central incisor and first molar associated "local" changes within the periodontium from "secondary" changes which reflect sutural and appositional growth at more distant osseous loci. Tracings were superimposed on anterior cranial base (ACB), on the maxillary implants only (IMP_MAX), and according to the best fit of maxillary anatomic structures without reference to the implants (A_MAX). Using the IMP_MAX superimposition, one could measure total local displacement at any landmark taking into consideration the effects of all appositional and resorptive changes on the superior and anterior surfaces of the palate, whereas using the A_MAX superimposition one could measure local displacement without consideration of surface appositional and resorptive changes. If the second of these measurements were subtracted from the first, the result would be a direct measurement of the effects of surface appositional and resorptive changes as they are expressed at that particular landmark. This strategy has enabled us to quantify and report the amount of accommodation which occurs at the location of each dental landmark in association with the resorptive and appositional changes which occur through time on the superior and anterior surfaces of the hard palate.

  9. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  10. Does Andrews facial analysis predict esthetic sagittal maxillary position?

    Science.gov (United States)

    Resnick, Cory M; Daniels, Kimberly M; Vlahos, Maryann

    2018-04-01

    Cephalometric analyses have limited utility in planning maxillary sagittal position for orthognathic surgery. In Six Elements of Orofacial Harmony, Andrews quantified maxillary position relative to forehead projection and angulation and proposed an ideal relationship. The purpose of this study was to investigate the ability of this technique to predict esthetic sagittal maxillary position. Survey study including a male and female with straight facial profiles, normal maxillary incisor angulations, and Angle's Class I. Maxillary position was modified on lateral photographs to create 5 images for each participant with incisor-goal anterior limit line (GALL) distances of -4, -2, 0, +2, and +4 mm. A series of health care professionals and laypeople were asked to rate each photo in order of attractiveness. A total of 100 complete responses were received. Incisor-GALL distances of +4 mm (41%) and +2 mm (40%) were most commonly considered "most esthetic" for the female volunteer (P < .001). For the male volunteer, there were 2 peak "most esthetic" responses: incisor-GALL distances of 0 mm (37%) and -4 mm (32%) (P < .001). Respondents considered maxillary incisor position 2 to 4 mm anterior to GALL most attractive in a woman and 0 to 4 mm posterior to GALL most esthetic in a man. Using these modified target distances, this analysis may be useful for orthognathic surgery planning. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    Science.gov (United States)

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  12. Optimization of the Conical Angle Design in Conical Implant-Abutment Connections: A Pilot Study Based on the Finite Element Method.

    Science.gov (United States)

    Yao, Kuang-Ta; Chen, Chen-Sheng; Cheng, Cheng-Kung; Fang, Hsu-Wei; Huang, Chang-Hung; Kao, Hung-Chan; Hsu, Ming-Lun

    2018-02-01

    Conical implant-abutment connections are popular for their excellent connection stability, which is attributable to frictional resistance in the connection. However, conical angles, the inherent design parameter of conical connections, exert opposing effects on 2 influencing factors of the connection stability: frictional resistance and abutment rigidity. This pilot study employed an optimization approach through the finite element method to obtain an optimal conical angle for the highest connection stability in an Ankylos-based conical connection system. A nonlinear 3-dimensional finite element parametric model was developed according to the geometry of the Ankylos system (conical half angle = 5.7°) by using the ANSYS 11.0 software. Optimization algorithms were conducted to obtain the optimal conical half angle and achieve the minimal value of maximum von Mises stress in the abutment, which represents the highest connection stability. The optimal conical half angle obtained was 10.1°. Compared with the original design (5.7°), the optimal design demonstrated an increased rigidity of abutment (36.4%) and implant (25.5%), a decreased microgap at the implant-abutment interface (62.3%), a decreased contact pressure (37.9%) with a more uniform stress distribution in the connection, and a decreased stress in the cortical bone (4.5%). In conclusion, the methodology of design optimization to determine the optimal conical angle of the Ankylos-based system is feasible. Because of the heterogeneity of different systems, more studies should be conducted to define the optimal conical angle in various conical connection designs.

  13. Comparison of implant component fractures in external and internal type: A 12-year retrospective study.

    Science.gov (United States)

    Yi, Yuseung; Koak, Jai-Young; Kim, Seong-Kyun; Lee, Shin-Jae; Heo, Seong-Joo

    2018-04-01

    The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

  14. Maxillary Sinus Floor Augmentation With Synthetic Bone Substitutes Compared With Other Grafting Materials

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Mordenfeld, Arne; Becktor, Jonas Peter

    2018-01-01

    OBJECTIVE: To test the hypotheses of no differences in implant treatment outcome after maxillary sinus floor augmentation (MSFA) with synthetic bone substitutes (SBS) compared with other grafting materials applying the lateral window technique. MATERIALS AND METHODS: A MEDLINE/PubMed, Embase and ...

  15. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification

    Directory of Open Access Journals (Sweden)

    Hamed A. Hamed

    2018-02-01

    Full Text Available AIM: This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS: Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05. RESULTS: Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. CONCLUSION: It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  16. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification.

    Science.gov (United States)

    Hamed, Hamed A; Marzook, Hamdy A; Ghoneem, Nahed E; El-Anwar, Mohamed I

    2018-02-15

    This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  17. Combined orthodontic-restorative management of maxillary central incisors lost following traumatic injury: a case report.

    Science.gov (United States)

    Fleming, Padhraig S; Seehra, Jadbinder; Dibiase, Andrew T

    2011-01-01

    A history of traumatic dental injury to the maxillary central incisors during preadolescence or adolescence is common and may result in premature loss. Treatment options include prosthetic implant replacement, autotransplantation, and orthodontic space closure with direct composite recontouring. This case report describes the treatment of an adolescent girl who presented with a crowded Class I malocclusion complicated by a history of trauma to the maxillary central incisors. The treatment plan consisted of orthodontic space closure following loss of both maxillary central incisors and mandibular premolars. This case highlights that orthodontic space closure can be a valuable treatment option in selected Class I crowded and Class II uncrowded malocclusions, producing predictable and efficient results.

  18. Osseointegration of a Zirconia Implant : A Histologic Assessment

    NARCIS (Netherlands)

    Schepke, Ulf; Meijer, Gert J; Meijer, Henny Ja; Walboomers, X Frank; Cune, Marco

    2017-01-01

    PURPOSE: The aim of this study was to describe the histologic and histomorphometric features of a retrieved, functional endosseous zirconia implant in a human subject. MATERIALS AND METHODS: A maxillary zirconia implant (ZV3) placed in a 52-year-old man was retrieved after 2 years of uncompromised

  19. An angle-resolved, wavelength-dispersive x-ray fluorescence spectrometer for depth profile analysis of ion-implanted semiconductors using synchrotron radiation

    Science.gov (United States)

    Schmitt, W.; Hormes, J.; Kuetgens, U.; Gries, W. H.

    1992-01-01

    An apparatus for angle-resolved, wavelength-dispersive x-ray fluorescence spectroscopy with synchrotron radiation has been built and tested at the beam line BN2 of the Bonn electron stretcher and accelerator (ELSA). The apparatus is to be used for nondestructive depth profile analysis of ion-implanted semiconductors as part of the multinational Versailles Project of Advanced Materials and Standards (VAMAS) project on ion-implanted reference materials. In particular, the centroid depths of depth profiles of various implants is to be determined by use of the angle-resolved signal ratio technique. First results of measurements on implants of phosphorus (100 keV, 1016 cm-2) and sulfur (200 keV, 1014 cm-2) in silicon wafers using ``white'' synchrotron radiation are presented and suggest that it should be generally possible to measure the centroid depth of an implant at dose densities as low as 1014 cm-2. Some of the apparative and technical requirements are discussed which are peculiar to the use of synchrotron radiation in general and to the use of nonmonochromatized radiation in particular.

  20. An angle-resolved, wavelength-dispersive x-ray fluorescence spectrometer for depth profile analysis of ion-implanted semiconductors using synchrotron radiation

    International Nuclear Information System (INIS)

    Schmitt, W.; Hormes, J.; Kuetgens, U.; Gries, W.H.

    1992-01-01

    An apparatus for angle-resolved, wavelength-dispersive x-ray fluorescence spectroscopy with synchrotron radiation has been built and tested at the beam line BN2 of the Bonn electron stretcher and accelerator (ELSA). The apparatus is to be used for nondestructive depth profile analysis of ion-implanted semiconductors as part of the multinational Versailles Project of Advanced Materials and Standards (VAMAS) project on ion-implanted reference materials. In particular, the centroid depths of depth profiles of various implants is to be determined by use of the angle-resolved signal ratio technique. First results of measurements on implants of phosphorus (100 keV, 10 16 cm -2 ) and sulfur (200 keV, 10 14 cm -2 ) in silicon wafers using ''white'' synchrotron radiation are presented and suggest that it should be generally possible to measure the centroid depth of an implant at dose densities as low as 10 14 cm -2 . Some of the apparative and technical requirements are discussed which are peculiar to the use of synchrotron radiation in general and to the use of nonmonochromatized radiation in particular

  1. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    Science.gov (United States)

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  2. Does the presence of antagonist remaining teeth affect implant overdenture success? A systematic review.

    Science.gov (United States)

    Ohkubo, C; Baek, K W

    2010-04-01

    Many patients who need implant overdentures are not completely edentulous; they still have antagonist natural teeth or implant fixed prostheses. In such cases, however, little is known about whether existing natural teeth affect the success of implant overdentures positively or act as a complicating factor. This systematic review attempts to clarify the correlation between existing remaining teeth and the survival/success rate of maxillary and mandibular implant overdentures. An assessment of available relevant articles published in English from 1990 to 2009 was performed using an online database and a manual search in libraries. Although the opposing natural dentition was not sufficiently described in the literature, 10 articles about the mandible and 10 articles about the maxilla were selected. As there was no controlled study on the natural teeth opposing implant overdentures, this review could not reach a clear conclusion. The review did reveal a remarkably high success/survival rate for mandibular implant overdentures; maxillary implant overdentures showed a lower rate. The presence of antagonist teeth hardly seems to be a risk factor for success for mandibular implant overdentures. For maxillary implant overdentures, the existence of antagonist teeth might act negatively for implant survival, but they are certainly not a contraindication. Although a few articles stated this relationship, we could not find an apparent correlation between the remaining antagonist teeth and the success of the implant overdentures. A detailed description of the opposing dentate status and results of randomized controlled clinical trials would be required to characterize this evidence-based implant overdenture treatment.

  3. A novel dental implant guided surgery based on integration of surgical template and augmented reality.

    Science.gov (United States)

    Lin, Yen-Kun; Yau, Hong-Tzong; Wang, I-Chung; Zheng, Cheng; Chung, Kwok-Hung

    2015-06-01

    Stereoscopic visualization concept combined with head-mounted displays may increase the accuracy of computer-aided implant surgery. The aim of this study was to develop an augmented reality-based dental implant placement system and evaluate the accuracy of the virtually planned versus the actual prepared implant site created in vitro. Four fully edentulous mandibular and four partially edentulous maxillary duplicated casts were used. Six implants were planned in the mandibular and four in the maxillary casts. A total of 40 osteotomy sites were prepared in the casts using stereolithographic template integrated with augmented reality-based surgical simulation. During the surgery, the dentist could be guided accurately through a head-mounted display by superimposing the virtual auxiliary line and the drill stop. The deviation between planned and prepared positions of the implants was measured via postoperative computer tomography generated scan images. Mean and standard deviation of the discrepancy between planned and prepared sites at the entry point, apex, angle, depth, and lateral locations were 0.50 ± 0.33 mm, 0.96 ± 0.36 mm, 2.70 ± 1.55°, 0.33 ± 0.27 mm, and 0.86 ± 0.34 mm, respectively, for the fully edentulous mandible, and 0.46 ± 0.20 mm, 1.23 ± 0.42 mm, 3.33 ± 1.42°, 0.48 ± 0.37 mm, and 1.1 ± 0.39 mm, respectively, for the partially edentulous maxilla. There was a statistically significant difference in the apical deviation between maxilla and mandible in this surgical simulation (p augmented reality technology. © 2013 Wiley Periodicals, Inc.

  4. Angle Performance on Optima XE

    International Nuclear Information System (INIS)

    David, Jonathan; Satoh, Shu

    2011-01-01

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were able to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1σ). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.

  5. Esthetic smile preferences and the orientation of the maxillary occlusal plane.

    Science.gov (United States)

    Kattadiyil, Mathew T; Goodacre, Charles J; Naylor, W Patrick; Maveli, Thomas C

    2012-12-01

    The anteroposterior orientation of the maxillary occlusal plane has an important role in the creation, assessment, and perception of an esthetic smile. However, the effect of the angle at which this plane is visualized (the viewing angle) in a broad smile has not been quantified. The purpose of this study was to assess the esthetic preferences of dental professionals and nondentists by using 3 viewing angles of the anteroposterior orientation of the maxillary occlusal plane. After Institutional Review Board approval, standardized digital photographic images of the smiles of 100 participants were recorded by simultaneously triggering 3 cameras set at different viewing angles. The top camera was positioned 10 degrees above the occlusal plane (camera #1, Top view); the center camera was positioned at the level of the occlusal plane (camera #2, Center view); and the bottom camera was located 10 degrees below the occlusal plane (camera #3, Bottom view). Forty-two dental professionals and 31 nondentists (persons from the general population) independently evaluated digital images of each participant's smile captured from the Top view, Center view, and Bottom view. The 73 evaluators were asked individually through a questionnaire to rank the 3 photographic images of each patient as 'most pleasing,' 'somewhat pleasing,' or 'least pleasing,' with most pleasing being the most esthetic view and the preferred orientation of the occlusal plane. The resulting esthetic preferences were statistically analyzed by using the Friedman test. In addition, the participants were asked to rank their own images from the 3 viewing angles as 'most pleasing,' 'somewhat pleasing,' and 'least pleasing.' The 73 evaluators found statistically significant differences in the esthetic preferences between the Top and Bottom views and between the Center and Bottom views (Pgender, profession, and race. The esthetic preference for the maxillary occlusal plane was influenced by the viewing angle with the

  6. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    Science.gov (United States)

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a

  7. Accurate registration of peri-implant soft tissues to create an optimal emergence profile

    Directory of Open Access Journals (Sweden)

    Ibraheem Fahad Alshiddi

    2015-01-01

    Full Text Available One of the challenges in restoring anterior space with implant restoration is maintaining the natural looking of peri-implant area. This case report presents a clinical procedure to create the soft tissue emergence profile for anterior maxillary teeth. A 49-year-old male presented with missing right maxillary lateral incisor. A provisional restoration was inserted 1 week after implant placement. Area of the provisional restoration related to the gingival tissue (transmucosal area was adjusted to create an optimum emergence profile. Two months later, an indirect method was used to accurately transfer the soft peri-implant tissues to the master cast. This clinical technique minimizes surgical procedure and avoids the possibility of soft tissue collapsing that may occur during the impression procedure.

  8. Evaluation of the rapid and slow maxillary expansion using cone-beam computed tomography: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Juliana da S. Pereira

    Full Text Available ABSTRACT OBJECTIVE: The aim of this randomized clinical trial was to evaluate the dental, dentoalveolar, and skeletal changes occurring right after the rapid maxillary expansion (RME and slow maxillary expansion (SME treatment using Haas-type expander. METHODS: All subjects performed cone-beam computed tomography (CBCT before installation of expanders (T1 and right after screw stabilization (T2. Patients who did not follow the research parameters were excluded. The final sample resulted in 21 patients in RME group (mean age of 8.43 years and 16 patients in SME group (mean age of 8.70 years. Based on the skewness and kurtosis statistics, the variables were judged to be normally distributed and paired t-test and student t-test were performed at significance level of 5%. RESULTS: Intermolar angle changed significantly due to treatment and RME showed greater buccal tipping than SME. RME showed significant changes in other four measurements due to treatment: maxilla moved forward and mandible showed backward rotation and, at transversal level both skeletal and dentoalveolar showed significant changes due to maxillary expansion. SME showed significant dentoalveolar changes due to maxillary expansion. CONCLUSIONS: Only intermolar angle showed significant difference between the two modalities of maxillary expansion with greater buccal tipping for RME. Also, RME produced skeletal maxillary expansion and SME did not. Both maxillary expansion modalities were efficient to promote transversal gain at dentoalveolar level. Sagittal and vertical measurements did not show differences between groups, but RME promoted a forward movement of the maxilla and backward rotation of the mandible.

  9. Implant planning on NobelClinician software‎ : incidence of bone density on the implants orientation for completely edentulous maxillae

    OpenAIRE

    Vankelst, Maëva

    2016-01-01

    The Purpose of this study wasto compare bone density in straight and tilted implants using the software NobelClinician on fifteen maxillary edentulous. For each patient, two schedules were created on NobelClinician: a first plan of 6 implants placed axially and a second plan where the last implant of each sector was tilted of 30 ° from the occlusal plane. The laying of the first four implants being common to both plans.The study was performed on DICOM files coming from the CBCT’s of 15 patien...

  10. Maxillary incisors changes during space closure with conventional and skeletal anchorage methods: a systematic review.

    Science.gov (United States)

    Jayaratne, Yasas Shri Nalaka; Uribe, Flavio; Janakiraman, Nandakumar

    2017-01-01

    The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes) and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration) were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. More RCT's that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  11. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  12. Diagnostic value of NobelGuide to minimize the need for reconstructive surgery of jaws before implant placement: a review.

    Science.gov (United States)

    Scotti, Roberto; Pellegrino, Gerardo; Marchetti, Claudio; Corinaldesi, Guiseppe; Ciocca, Leonardo

    2010-01-01

    To test if using a CAD/CAM system might reduce the necessity of bone augmentation in patients with atrophic maxillary arches before implant therapy. Twenty male and female patients consecutively scheduled for bone augmentation of the jaw before implant surgery were included in this study, with a total of 29 jaws (maxillary and mandibular) to analyze for the implant-supported fixed prosthesis group and 19 maxillary arches for the implant-supported removable prosthesis group. NobelGuide System (Nobel Biocare), Autocad System (Autodesk), and routine manual CT measurements of available bone were used in this study. The total results of the mean values of the fixed prosthesis group plus the mean values of the removable prosthesis group showed a statistically significant difference between the NobelGuide intervention score and both manual (P = .004) and Autocad (P = .001) measurements. The NobelGuide System represents a viable diagnostic device to reduce the entity or avoid bone reconstructive surgery before implant placements in the atrophic maxilla and mandible.

  13. Root canal treatment of bilateral three-rooted maxillary first premolars

    Directory of Open Access Journals (Sweden)

    Bhavana Gandhi

    2012-01-01

    Full Text Available In endodontics, several anatomic variations occur in teeth, both externally and in the internal root morphology, which play a very significant role in the diagnosis and treatment outcome. A thorough knowledge of the root canal anatomy, careful interpretation of the angled radiographs, proper endodontic access cavity preparation, and exploration of the root canal are the prerequisites for endodontic success. In a maxillary first premolar, it is rare to find extra roots and canals, and the aim of the present article is to report a case about the successful diagnosis and clinical management of bilateral three-rooted maxillary first premolars, with three independent root canals.

  14. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report.

    Science.gov (United States)

    Amet, Edward M; Uehlein, Chris

    2013-12-01

    The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.

  15. Mini-screw implant or transpalatal arch-mediated anchorage reinforcement during canine retraction: a randomized clinical trial.

    Science.gov (United States)

    Sharma, Mohit; Sharma, Vineet; Khanna, Bharat

    2012-06-01

    To compare mesial movement of upper first molars during maxillary canine retraction using a pre-adjusted edgewise appliance provided by anchorage reinforcement and a transpalatal arch or mini-screw implant. Randomized clinical trial. Department of Orthodontics and Dentofacial Orthopedics, Armed Forces Medical College, Pune, India. From a cohort of subjects requiring the extraction of both upper first premolars and pre-adjusted edgewise appliances to correct their malocclusion, a total of 30 were randomly allocated to receive two different forms of anchorage reinforcement: group A--receiving mini-screw implant and group B--receiving a transpalatal arch Group A subjects received titanium mini-screw implants placed at the start of treatment between the maxillary second premolar and maxillary first molar. Maxillary second premolars were secured to the mini-screw implants using of 0.010-inch stainless steel ligature wire. Group B subjects received a custom-made transpalatal arch which was soldered to maxillary first molar bands. Active canine retraction was initiated in both groups on placement of a 0.019×0.025-inch stainless steel archwire using nickel titanium closed coil springs. Mesial movement of the upper first molars as measured on pre- (T1) and post-treatment (T2) lateral skull radiographs. The results showed that in group A the mean mesial movement of the first molars between T1 and T2 was 0.0 mm (SD 0.02; P = 0.90), whereas in Group B there was a mean forward movement of the first maolars of 2.48 mm (SD 0.71; Pimplants placed prior to levelling and aligning were able to provide absolute anchorage during maxillary canine retraction, in contrast to a transpalatal arch.

  16. Pterygoid implants for maxillofacial rehabilitation of a patient with a bilateral maxillectomy defect.

    Science.gov (United States)

    Bidra, Avinash S; May, George W; Tharp, Greggory E; Chambers, Mark S

    2013-02-01

    Bilateral maxillectomy is known to have serious esthetic and functional consequences. The retention and support of a maxillary obturator prosthesis in these patients is particularly challenging. Surgical placement of implants is also challenging because of the lack of available bone. Therefore, implant placement into remote sites such as zygoma has been advocated. Very few articles in the literature have discussed the use of pterygoid/pterygomaxillary implants in patients undergoing maxillectomy. This case report describes the maxillofacial rehabilitation of an elderly man who underwent a bilateral subtotal maxillectomy due to basaloid squamous cell carcinoma of the hard palate. After initial healing, the patient had a pterygoid implant placed on each side of the oral cavity. Zygomatic implants were also attempted, but they failed to osseointegrate. Both pterygoid implants showed successful osseointegration. These 2 implants significantly helped to retain a hollow maxillary obturator prosthesis that aided in improved swallowing, speech, and esthetics. To the authors' knowledge, this is the first report in the literature that describes usage of pterygoid implants for rehabilitation of a patient undergoing bilateral maxillectomy.

  17. Prevalence of bony septa, antral pathology, and dimensions of the maxillary sinus from a sinus augmentation perspective: A retrospective cone-beam computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Jalali, Elnaz; Al Salman, Wesam; Jambhekar, Shantanu; Katechia, Bina [University of Connecticut, School of Dental Medicine, Farmington (United States); Almas, Khalid [Div. of Periodontology, University of Dammam, College of Dentistry, Dammam (Saudi Arabia)

    2016-06-15

    Sinus elevation procedures have become a routine and reliable way to gain bone volume in the edentulous maxilla for dental implant placement. Presence of bony septations and pathology in the maxillary sinus often cause complications leading to graft or implant failure or both. The aim of this study was to retrospectively evaluate the prevalence of pathology, direction of the septa, and sinus width measured at 2 mm, 5 mm, and 10 mm from the sinus floor in maxillary sinuses using cone-beam computed tomography (CBCT). Seventy-two sinuses from 36 random preoperative CBCT scans referred for implant therapy were retrospectively evaluated for the number, prevalence, and direction of bony septations and presence of pathology. Width of the sinus was also measured at 2 mm, 5 mm, and 10 mm from the sinus floor to account for the amount of bone available for implant placement. Maxillary sinus septa were found in 59.7%. Presence of a single septum was noted in 20 sinuses (27.7%), followed by two septa in 17 sinuses. The most common direction of the septum was the transverse direction. Retention pseudocyst and mucosal thickening were the most commonly seen abnormality/pathology. Based on the high prevalence of septa and sinus pathology in this sample, a preoperative CBCT scan might be helpful in minimizing complications during sinus augmentation procedures for dental implant therapy.

  18. Prevalence of bony septa, antral pathology, and dimensions of the maxillary sinus from a sinus augmentation perspective: A retrospective cone-beam computed tomography study

    International Nuclear Information System (INIS)

    Tadinada, Aditya; Jalali, Elnaz; Al Salman, Wesam; Jambhekar, Shantanu; Katechia, Bina; Almas, Khalid

    2016-01-01

    Sinus elevation procedures have become a routine and reliable way to gain bone volume in the edentulous maxilla for dental implant placement. Presence of bony septations and pathology in the maxillary sinus often cause complications leading to graft or implant failure or both. The aim of this study was to retrospectively evaluate the prevalence of pathology, direction of the septa, and sinus width measured at 2 mm, 5 mm, and 10 mm from the sinus floor in maxillary sinuses using cone-beam computed tomography (CBCT). Seventy-two sinuses from 36 random preoperative CBCT scans referred for implant therapy were retrospectively evaluated for the number, prevalence, and direction of bony septations and presence of pathology. Width of the sinus was also measured at 2 mm, 5 mm, and 10 mm from the sinus floor to account for the amount of bone available for implant placement. Maxillary sinus septa were found in 59.7%. Presence of a single septum was noted in 20 sinuses (27.7%), followed by two septa in 17 sinuses. The most common direction of the septum was the transverse direction. Retention pseudocyst and mucosal thickening were the most commonly seen abnormality/pathology. Based on the high prevalence of septa and sinus pathology in this sample, a preoperative CBCT scan might be helpful in minimizing complications during sinus augmentation procedures for dental implant therapy

  19. Impact of Platform Switching on Peri-Implant Bone Remodeling around Short Implants in the Posterior Region, 1-Year Results from a Split-Mouth Clinical Trial

    NARCIS (Netherlands)

    Telleman, Gerdien; Raghoebar, Gerry M.; Vissink, Arjan; Meijer, Henny J. A.

    Aim: To assess the effect of platform switching on peri-implant bone remodeling around short implants (8.5mm) placed in the resorbed posterior mandibular and maxillary region of partially edentulous patients. Materials and Methods: Seventeen patients with one or more missing teeth at both sides in

  20. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Directory of Open Access Journals (Sweden)

    Marcia Regina Ramalho da Silva Bardauil

    2010-09-01

    Full Text Available This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP, and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA. The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP, with a 20º variation of the horizontal angle (GM and 25º variation of the horizontal angle combined with 15º vertical angle (GMV. Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV to dissociate maxillary premolar roots in both radiography systems.

  1. Skeletal response to maxillary protraction with and without maxillary expansion: a finite element study.

    Science.gov (United States)

    Gautam, Pawan; Valiathan, Ashima; Adhikari, Raviraj

    2009-06-01

    The purpose of this finite element study was to evaluate biomechanically 2 treatment modalities-maxillary protraction alone and in combination with maxillary expansion-by comparing the displacement of various craniofacial structures. Two 3-dimensional analytical models were developed from sequential computed tomography scan images taken at 2.5-mm intervals of a dry young skull. AutoCAD software (2004 version, Autodesk, San Rafael, Calif) and ANSYS software (version 10, Belcan Engineering Group, Cincinnati, Ohio) were used. The model consisted of 108,799 solid 10 node 92 elements, 193,633 nodes, and 580,899 degrees of freedom. In the first model, maxillary protraction forces were simulated by applying 1 kg of anterior force 30 degrees downward to the palatal plane. In the second model, a 4-mm midpalatal suture opening and maxillary protraction were simulated. Forward displacement of the nasomaxillary complex with upward and forward rotation was observed with maxillary protraction alone. No rotational tendency was noted when protraction was carried out with 4 mm of transverse expansion. A tendency for anterior maxillary constriction after maxillary protraction was evident. The amounts of displacement in the frontal, vertical, and lateral directions with midpalatal suture opening were greater compared with no opening of the midpalatal suture. The forward and downward displacements of the nasomaxillary complex with maxillary protraction and maxillary expansion more closely approximated the natural growth direction of the maxilla. Displacements of craniofacial structures were more favorable for the treatment of skeletal Class III maxillary retrognathia when maxillary protraction was used with maxillary expansion. Hence, biomechanically, maxillary protraction combined with maxillary expansion appears to be a superior treatment modality for the treatment of maxillary retrognathia than maxillary protraction alone.

  2. Brain abscess following dental implant placement via crestal sinus lift - a case report.

    Science.gov (United States)

    Manor, Yifat; Garfunkel, Adi A

    2018-01-01

    To describe a rare case of odontogenic brain abscess. A healthy, 35-year-old male had two dental implants placed in a simultaneously augmented maxillary sinus. One implant failed and the patient developed a maxillary sinusitis that failed to improve following antibiotic treatment at home. The neglected sinus infection led to formation of a brain abscess. The patient was hospitalised only when he had pan sinusitis with neurological signs. Symptoms were headache attacks, a subfebrile fever and a purulent secretion from the left nostril. The osteomeatal complex was blocked, the maxillary sinus was filled with pus and the Schneiderian membrane thickened. The patient was treated with intravenous antibiotic treatment. Computerised tomography (CT) and magnetic resonance imaging (MRI) scans and functional endoscopic sinus surgery (FESS), were implemented. When his conditions worsened, the patient underwent a left frontal mini craniotomy. Following the craniotomy and antibiotic treatment, there was a gradual resolution and the patient was dismissed after 2 months in hospital with no neurological deficit or signs of sinusitis. Maxillary sinusitis following dental implant insertion and concomitant maxillary sinus elevation should be treated immediately and thoroughly since untreated sinusitis may cause life-threatening situations such as a brain abscess. In case of severe infection, clinicians should refer immediately the patient to hospital specialists. Conflict-of-interest statement: The authors have stated explicitly that there are no conflicts of interest. The manuscript was self-funded.

  3. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  4. Effects of maxillary sinus floor elevation surgery on maxillary sinus physiology

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; Liem, RSB; van Weissenbruch, R; Manson, WL; Vissink, A

    In a prospective study, the effects of elevation surgery of the maxillary sinus floor on maxillary sinus physiology were assessed. Seventeen consecutive patients without preoperative anamnestic, clinical and radiological signs of maxillary sinusitis underwent sinus floor elevation surgery with iliac

  5. Nonsurgical, nonextraction management of impacted maxillary canine

    Directory of Open Access Journals (Sweden)

    Jasneet Singh

    2018-01-01

    Full Text Available NS, a 12 year 2 months old female patient, presented with the chief complaint of irregular teeth. Diagnosis revealed skeletal Class II jaw base relation, with average (toward vertical growth pattern, dentoalveolar angles Class I molar relationship with severe crowding in upper and moderate crowding in the lower arch, normally positioned maxillary incisors but proclined lower incisors, “V” shape constricted maxillary arch with first premolar in crossbite, overretained deciduous molar and a high placed buccoversion canine in the first quadrant and an impacted canine in the second quadrant, constricted mandibular arch with first premolar blocked out in the third quadrant. Treatment with a nonsurgical, nonextraction treatment plan by expansion of the upper arch and taking advantage of natural eruptive forces of the tooth was planned. The final outcome solved the patient's complaints and achieved an esthetically pleasing and functionally adequate occlusal result.

  6. MAXILLARY INCISORS CHANGES DURING SPACE CLOSURE WITH CONVENTIONAL AND SKELETAL ANCHORAGE METHODS: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    Yasas Shri Nalaka JAYARATNE

    2017-12-01

    Full Text Available Purpose: The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. Materials and Methods: The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Results: Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. Conclusion: More RCT’s that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  7. The Palatal Approach to Distraction Osteogenesis of the Anterior Maxillary Alveolus.

    Science.gov (United States)

    Bell, Robert E

    2015-07-01

    This report describes the palatal approach to gain access for osteodistraction of the anterior maxilla to improve the vector of force during distraction. This case report illustrates a novel approach to anterior maxillary osteodistraction. The palatal approach allows the maxillary segment to be moved anteriorly and inferiorly. This is in contrast to the buccal approach, in which the palatal tissue creates a vector of force toward the palate. The vascular pedicle for the transport segment is the labial mucosa and musculature. In the present case, the alveolar segment was advanced 3.6 mm anteriorly and 12.2 mm inferiorly as measured by pre- and postoperative computed tomograms. This patient with a large vertical alveolar defect and high smile line had successful restoration with dental implants. The result has been stable for 14 months. In this case, the palatal approach to the anterior maxillary osteotomy was shown to be an effective method of reconstructing a large vertical anterior defect. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Bimaxillary protrusion with an atrophic alveolar defect: orthodontics, autogenous chin-block graft, soft tissue augmentation, and an implant.

    Science.gov (United States)

    Chiu, Grace S C; Chang, Chris H N; Roberts, W Eugene

    2015-01-01

    Bimaxillary protrusion in a 28-year-old woman was complicated by multiple missing, restoratively compromised, or hopeless teeth. The maxillary right central incisor had a history of avulsion and replantation that subsequently evolved into generalized external root resorption with Class III mobility and severe loss of the supporting periodontium. This complex malocclusion had a discrepancy index of 21, and 8 additional points were scored for the atrophic dental implant site (maxillary right central incisor). The comprehensive treatment plan included extraction of 4 teeth (both maxillary first premolars, the maxillary right central incisor, and the mandibular right first molar), orthodontic closure of all spaces except for the future implant site (maxillary right central incisor), augmentation of the alveolar defect with an autogenous chin-block graft, enhancement of the gingival biotype with a connective tissue graft, and an implant-supported prosthesis. Orthodontists must understand the limitations of bone grafts. Augmented alveolar defects are slow to completely turn over to living bone, so they are usually good sites for implants but respond poorly to orthodontic space closure. However, postsurgical orthodontic treatment is often indicated to optimally finish the esthetic zone before placing the final prosthesis. The latter was effectively performed for this patient, resulting in a total treatment time of about 36 months for comprehensive interdisciplinary care. An excellent functional and esthetic result was achieved. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  9. Reliability of implant surgical guides based on soft-tissue models.

    Science.gov (United States)

    Maney, Pooja; Simmons, David E; Palaiologou, Archontia; Kee, Edwin

    2012-12-01

    The purpose of this study was to determine the accuracy of implant surgical guides fabricated on diagnostic casts. Guides were fabricated with radiopaque rods representing implant positions. Cone beam computerized tomograms were taken with guides in place. Accuracy was evaluated using software to simulate implant placement. Twenty-two sites (47%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). Soft-tissue models do not always provide sufficient accuracy for fabricating implant surgical guides.

  10. Trans-sinusal maxillary distraction for correction of midfacial hypoplasia: long-term clinical results.

    Science.gov (United States)

    Nadjmi, N; Schutyser, F; Van Erum, R

    2006-10-01

    Maxillary distraction osteogenesis is indicated in severe angle class III malocclusions, and severe maxillary hypoplasia among some cleft patients and other craniofacial deformities. Twenty patients, aged 8-48 years (mean 17.8+/-10.5 SD) with maxillary and midfacial hypoplasia were treated. The follow-up period was 13-65 months (mean 35+/-16.3 SD). A trans-sinusal maxillary distractor was placed intraorally at each side of the maxilla. The distraction vector was predicted using specialist software, and was transferred to the patients using stereolithographic models and individual templates. A (high) Le Fort I type osteotomy was performed. The amount of activation varied from 8 to 17.5 mm (mean 13.1+/-2.9 SD). Soft and hard tissue formation resulted in complete healing across the distraction gaps. The distractors are almost completely submerged, and can be left in place as long as necessary to avoid relapse. Wit's appraisal was used to measure the stability of the long-term distraction results. Results up to 5 years after distraction showed considerable maxillary advancement with long-term stability. Ongoing growth of the facial skeleton must be considered when distraction osteogenesis is chosen in growing patients.

  11. Space closure in the maxillary posterior area through the maxillary sinus.

    Science.gov (United States)

    Park, Jae Hyun; Tai, Kiyoshi; Kanao, Akira; Takagi, Masato

    2014-01-01

    A common dilemma in adult orthodontic treatment is deciding how best to treat missing posterior teeth. One treatment option is to orthodontically close the space. But closure can be difficult, especially if the open space is in the maxillary posterior area, because tooth movement through the maxillary sinus is limited. The increased difficulty of moving teeth in the maxillary sinus is similar to moving a tooth in the atrophic posterior mandibular ridge. If space closure is selected as a treatment method, proper mechanics and light forces should be applied. In this article, we report movement of teeth through the maxillary sinus and discuss various implications related to orthodontic treatment in the maxillary sinus. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  12. Rehabilitation of large maxillary defect with two-piece maxillary obturators

    Directory of Open Access Journals (Sweden)

    Kanchan P Dholam

    2015-01-01

    Full Text Available The insertion and removal of an obturator in large maxillary defects with or without trismus is difficult. Fabrication of a two-piece obturator in such cases overcomes this problem. This article describes rehabilitation of large maxillary defects with two piece maxillary obturator of three types. All these obturators have a maxillary plate and a bulb component, which are approximated together by various techniques namely, silicone cover, embedded magnets, and press studs. Prosthetic rehabilitation of large maxillary defects with two-piece obturators offers the possibility of adequate oral rehabilitation by fabricating light weight prosthesis, which is easy to use. The bulb covers the undercut areas of the defect enhancing the facial contour and retention. It facilitates easy examination of underlying tissues, recreation of the anatomic barrier between the oral and nasal cavities and restoration of the function and esthetics. Thus, it adds to the quality of life.

  13. Group Distal Movement of Teeth using Micro-Screw-Implant Anchorage-A Case Report.

    Science.gov (United States)

    Kalarickal, Biju

    2014-05-01

    This case report describes a case of orthodontic tooth movement of a 29-year-old female patient utilizing maxillary posterior edentulous area. Micro-implants were placed at buccal edentulous spaces and inter-radicular space for retraction of entire maxillary dentition. An overjet reduction of 8mm and good posterior occlusion were achieved.

  14. Treatment Outcome and Patient Satisfaction with Two Adjacent Implant-Supported Restorations in the Esthetic Zone

    NARCIS (Netherlands)

    Tymstra, Nynke; Meijer, Henny J. A.; Stellingsma, Kees; Raghoebar, Gerry M.; Vissink, Arjan

    2010-01-01

    The purpose of this study was to evaluate the clinical and radiographic parameters as well as the esthetic outcome of two adjacent implant-supported restorations and the surrounding peri-implant mucosa in the maxillary esthetic zone. Ten patients were treated with two adjacent implants in the

  15. Evaluation of the influence exerted by different dental specialty backgrounds and measuring instrument reproducibility on esthetic aspects of maxillary implant-supported single crown.

    Science.gov (United States)

    Vaidya, Samriddhi; Ho, Yu Lau Elaine; Hao, Jie; Lang, Niklaus P; Mattheos, Nikos

    2015-03-01

    To evaluate the influence exerted by different dental specialty backgrounds as well as the validity and reproducibility of the Pink Esthetic Score/White Esthetic Score (PES/WES) and the modified Implant Crown Aesthetic Index (mod-ICAI) on the assessment of esthetic aspects of maxillary implants supported single-tooth prosthesis. A total of fourteen examiners (Two orthodontists, two prosthodontists, two oral surgeons, two periodontists, two dental technicians, two dental assistants, and two postgraduate students in Implant Dentistry evaluated 20 photographs of single-implant-supported crowns and five photographs of unrestored teeth of esthetic zone in a two part study. The examiners assessed the photographs with each index (Pink Esthetic Score/White Esthetic Score and modified Implant Crown Aesthetic Index), twice with a week's interval. Orders of photographs were rearranged in the second assessment. Kruskal-Wallis test results showed significant differences among all the six specialties (P ≤ 0.001). DAs and periodontists had significantly better ratings than other specialties with both indices. Prosthodontists had the lowest mean rank scores regardless of the index. Interobserver agreement was also lowest between the two prosthodontists (4-28%), rest of the groups had low-to-moderate agreement (20-80%) when limited allowance was accepted. With mod-ICAI, more interobserver agreement was noted within the specialty group than with PES/WES. The PES/WES and the modified ICAI can be reliable estimates of esthetic outcomes. The assessor degree of specialization affected the esthetic evaluation with both the PES/WES and the modified ICAI. DAs and periodontists were identified to provide more favorable ratings than other specialties while prosthodontists were most critical in this study. With modified ICAI, more interobserver agreement within specialty resulted. The interexaminer agreement may be increased if more tolerance of 1-2 points is considered. © 2014 John Wiley

  16. Permanent maxillary canines - review of eruption pattern and local etiological factors leading to impaction.

    Science.gov (United States)

    Sajnani, Anand K

    2015-02-01

    The position of the permanent maxillary canine at the angle of the mouth is strategically significant in maintaining the harmony and symmetry of the occlusal relationship. However, the maxillary canine is the second most frequently impacted tooth, with prevalence reported to be between 1% and 2%. Moreover, treatment of this condition is often complex and involves substantial time and financial cost. Hence, it is only prudent to monitor the eruption and identify the etiological factors that lead to impaction of the maxillary canine. Numerous researchers have tried to identify specific and nonspecific etiological factors responsible for displacement of canines. The purpose of this review was to track the development processes of maxillary canines and determine the hindrances that affect the eruption at different ages. Awareness of the eruption process and etiology of noneruption will help to reduce the incidence of impacted canines by allowing for early recognition and interceptive treatment. © 2013 Wiley Publishing Asia Pty Ltd.

  17. Maxillary second molar with four roots and five canals

    Directory of Open Access Journals (Sweden)

    Xinjia Sha

    2018-06-01

    Full Text Available In this case report, we present a maxillary second molar variant, which had two palatal roots with two canals and two buccal roots with three canals, including a second mesiobuccal canal. A 44-year-old female patient complained about a tooth crown fracture and severe pain in her right maxillary second molar. A clinical intraoral inspection and radiography were carried out on the tooth, and a diagnosis of chronic apical periodontitis was made. Four roots (two buccal and two palatal and five canals (three buccal and two palatal were found. The anatomical variation of the tooth was further confirmed by cone-beam computed tomography, a cone-fit procedure, and a radiograph with a shifted projection angle. Root-canal treatment was performed under an endodontic microscope.

  18. Comparative study of longitudinal changes in peri-implant bone microstructure

    International Nuclear Information System (INIS)

    Suzuki, Yusuke; Matsunaga, Satoru; Abe, Shinichi; Ide, Yoshinobu; Usami, Akinobu

    2010-01-01

    The load applied to an implant is directly transmitted to the jaw and is considered to be one of the causes of remodeling of internal trabecular bones. However, the longitudinal changes during loading and the rearrangement of the trabecular bone structure are mostly unknown. The aim of this study was to clarify the changes in internal jaw bone structure longitudinally during natural tooth eruption as well as tooth extraction and post-implantation periods in a dog model by micro computed tomography (micro-CT). Maxillae of 16 male beagle dogs were used in this study. First, 4 dogs with all maxillary molar teeth erupted were euthanized as a control group. Next, 6 teeth consisting of the bilateral maxillary fourth premolars, and first and second molars were extracted from each of the 12 dogs. Then, 4 dogs of the tooth-extracted group were euthanized 3 months after extraction of the teeth. At this time, three implants were inserted in the left side of the maxilla of the remaining 8 dogs, and the superstructures were placed after 3 months. Four of these 8 dogs with implants were euthanized at 3 months and the other 4 at 1 year after placement of the superstructure. Then, the maxillary bone was removed from each dog as a specimen and sequential micro-CT images were taken. After reconstruction of three-dimensional images, morphological and metrical observation of the jaw trabecular bone structure was performed. A decrease of the trabecular bone in the tooth-extracted group was morphologically and morphometrically observed, whereas the implanted group showed thick, rich trabecular bone. Although a longitudinal decrease in the bone tissue volume was recognized both in the tooth-extracted and the implanted groups, the amount was smaller in the implanted group than in the tooth-extracted group. The results suggested that the application of load by implants in the case of tooth loss inhibits resorption of the alveolar bone and prevents thinning of the jaw. (author)

  19. The relationship between pharyngeal morphology measured with cone-beam computed tomography and maxillary morphology measured by lateral cephalogram

    International Nuclear Information System (INIS)

    Yamaguchi, Fumie; Yamaguchi, Tetsutaro; Miyamoto, Asami; Maki, Koutaro

    2007-01-01

    This study examined the relationship between pharyngeal morphology measured with cone-beam computed tomography (CBCT) and maxillary morphology measured from lateral cephalograms. The subjects comprised 45 women, with a mean age of 27.9 years (range, 16-50 years), who attended the Department of Orthodontics at Showa University. The evaluation of pharyngeal morphology was based on 9 variables measured by CBCT: pharyngeal space volume, pharyngeal vertical length, pharyngeal sagittal length, pharyngeal coronal length, epiglottis length, epiglottis width, the distance from the genion to the hyoidale, the distance from the hyoidale to the aditus larynges base, and the distance from the aditus larynges base to the genion. Maxillary morphology was evaluated from 5 measured sites: SNA, S'-Ptm', A'-Ptm', the occiusal plane angle, and the palatal plane angle. Pearson's correlation coefficient was used to detect associations between pharyngeal and maxillary morphological variables. There were significant correlations between pharyngeal coronal length and SNA, the distance from the genion to the hyoidale and the occlusal plane angle, pharyngeal coronal length and A'-Ptm', pharyngeal vertical length and the palatal plane angle, as well as the aditus larynges base to the genion and the occlusal plane. This information has potential clinical value for better understanding obstructive sleep apnea in adult patients, and for structurally based treatments such as surgical orthodontics. (author)

  20. Orthodontic-surgical treatment of bilateral maxillary canine impaction

    OpenAIRE

    Sumitra

    2012-01-01

    A 13-year-old female patient reported with the chief complaint of irregular front teeth. She had a skeletal Class III and Angle's Class I malocclusion with hyperdivergent growth pattern and bilateral impaction of maxillary canines. Surgical exposure of the impacted teeth and orthodontic alignment was planned. The surgical exposure was done by a minimally invasive modified window technique. Orthodontic treatment of impacted canines without causing significant morbidity to the adjacent teeth an...

  1. Maxillary Hypoplasia With Congenital Oligodontia Treated by Maxillary Distraction Osteogenesis.

    Science.gov (United States)

    Mishima, Sayaka; Yamaguchi, Takako; Watanabe, Takuma; Komatani, Toru; Nakao, Kazumasa; Takahashi, Katsu; Bessho, Kazuhisa

    2018-02-27

    It is known that congenitally missing teeth can often cause differences in craniofacial morphology; however, there are few reported cases of orthognathic surgical treatment for these patients. Herein, the authors report a rare case of maxillary hypoplasia with congenital oligodontia treated by maxillary distraction osteogenesis with internal device. A 17-year-old male presenting with multiple tooth agenesis and maxillary recession was referred to our hospital for orthognathic surgical treatment. Preoperative simulation surgery was performed using Full-Color 3-dimensional salt model. After surgery, improvement in maxillary recession and occlusal stability was observed. This report demonstrates the advantages of the method used herein, which includes reduction in operating time with increase in the safety of the procedure.

  2. Stress distribution and displacement of maxillary anterior teeth during en-masse intrusion and retraction: A FEM study

    Directory of Open Access Journals (Sweden)

    Parag Bohara

    2017-01-01

    Full Text Available Background: Space closure by en masse intrusion and retraction in orthodontics is of particular interest. Aim: The aim of this study was to evaluate the stress distribution and displacement of maxillary anterior teeth. Materials and Methods: Four different finite element models of maxillary arch were constructed to understand the nature of stresses and displacement patterns of anterior teeth during en masse intrusion and retraction on force application with different combinations of mini-implants and retraction hooks. Results: In this study, tensile stresses were seen in the cervical region and various movements of teeth such as lingual crown tipping, bodily movement, lingual root tipping, intrusion, and extrusion were observed. Conclusion: Nature of stresses changes from tensile to compressive from cervical area to apical area. Various tooth displacements suggest that different combinations of mini-implants and retraction hooks affect the direction of the tooth movement.

  3. Maxillary sinus lift with solely autogenous bone compared to a combination of autogenous bone and growth factors or (solely) bone substitutes. A systematic review : a systematic review

    NARCIS (Netherlands)

    Rickert, D.; Slater, J. J. R. Huddleston; Meijer, H. J. A.; Vissink, A.; Raghoebar, G. M.

    Literature regarding the outcome of maxillary sinus floor elevation to create sufficient bone fraction to enable implant placement was systematically reviewed. Bone fraction and implant survival rate were assessed to determine whether grafting material or applied growth factor affected bone

  4. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol

    Directory of Open Access Journals (Sweden)

    Corina Marilena Cristache

    2017-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Materials and Methods. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann–Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Results. Mean (and standard deviation of 3D error at the entry point was 0.798 mm (±0.52, at the implant apex it was 1.17 mm (±0.63, and mean angular deviation was 2.34 (±0.85. A statistically significant reduced 3D error was observed at entry point p=.037, at implant apex p=.008, and also in angular deviation p=.030 in mandible when comparing to maxilla. Conclusions. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.

  5. Analysis of the golden proportion and width/height ratios of maxillary anterior dentition in patients with lateral incisor agenesis.

    Science.gov (United States)

    Pini, Núbia Pavesi; de-Marchi, Luciana Manzotti; Gribel, Bruno Frazão; Ubaldini, Adriana Lemos Mori; Pascotto, Renata Corrêa

    2012-12-01

      The purpose of this study was to assess the presence of the golden proportion (GP) in the facial view tooth-to-tooth width proportion of the six maxillary anterior teeth and to evaluate the width/height (W/H) ratios of the incisors of patients with maxillary lateral incisor (LI) agenesis treated either with implants or orthodontically (by moving canines into the position of the laterals, recontouring them, and placing composite restorations over the repositioned teeth).   Forty-eight patients with LI agenesis were divided into four experimental groups: unilateral recontouring group (N = 10), bilateral recontouring group (BRG, N = 18), unilateral implant group (UIG, N = 10), bilateral implant group (N = 10), and a control group (CG, N = 25) of patients without agenesis. GP ratios were determined on patients' dental casts placed over Levin's grids, whereas W/H ratios were measured directly on the casts and a millimeter ruler to determine these distances. Statistical analysis was performed with Shapiro-Wilk, Kruskal-Wallis, Mann-Whitney, Friedman, and Wilcoxon tests (p mean W/H ratios of the laterals ranged between 0.75 and 0.90.   Although the GP may be a useful diagnostic guide, it was not observed in the majority of esthetic outcomes of patients treated with maxillary LI agenesis in this study. The assessment of the golden proportion and width/height ratio of upper anterior teeth in patients with upper lateral incisor agenesis treated with either implants or tooth re-contouring may assist dentists and patients in deciding the best treatment option based on the peculiarities of each case. © 2012 Wiley Periodicals, Inc.

  6. Changes in the edentulous maxilla with ball and telescopic attachments of implant-retained mandibular overdentures: a 4-year retrospective study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Khairallah, Ahmed Samir; Shawky, Ahmad Fathalla

    2013-07-01

    This retrospective study investigated the clinical and radiographic changes in the edentulous maxilla in patients with either ball or telescopic attachments of implantretained mandibular overdentures. Thirty-two completely edentulous patients (21 males and 11 females) received two implants in the canine region of the mandible. New maxillary complete dentures and mandibular overdentures were fabricated. Overdentures were connected to the implants either with ball (group 1, n = 16) or telescopic (group 2, n = 16) attachments. Retention and stability of the maxillary denture as well as mucosal changes of the maxillary ridge were recorded after 4 years of denturewearing. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 4 years (T4) of overdenture insertion was calculated for the anterior and posterior regions of the maxilla. After 4 years of denture-wearing, maxillary denture retention was significantly higher in group 1 than in group 2, while occurrence of flabby ridges was significantly higher in group 2 than in group 1. The change in R of the anterior region of the maxilla was significantly higher than the change in the posterior region in both groups. Group 2 showed significant anterior residual ridge resorption compared to group 1. Telescopic attachments for implant-retained mandibular overdentures are associated with increased maxillary ridge resorption and flabbiness, and decreased maxillary denture retention when compared to ball attachments.

  7. Maxillary Distraction Osteogenesis in Unilateral Cleft Lip and Palate Patients with Rigid External Distraction System.

    Science.gov (United States)

    Alkhouri, Shadi; Waite, Peter D; Davis, Matthew B; Lamani, Ejvis; Kau, Chung How

    2017-01-01

    Distraction osteogenesis (DO) is a treatment option for patients with maxillary hypoplasia secondary to cleft lip and palate (CLP). The aim of this study is to present a technique for maxillary DO using Le Fort I osteotomy with rigid external distraction (RED) system. The patient presented in this paper was an Asian female with CLP aged 13 years and 6 months. She presented with severe midfacial deficiency with a Class III dental malocclusion with a negative overjet and concave facial profile. Cone-beam computed tomography images were recorded preoperatively and the operation performed involved a high Le Fort I osteotomy. The appliance fabricated was banded to upper first molars used for anchorage of the RED system. Distraction of the maxilla was initiated after 7-day latency period. Postoperative cephalometric analysis showed maxillary advancement anteriorly and superiorly, the total distraction treatment period was 10 days. The maxillary advancement was 10.5 mm and the SNA angle increased from 67.5° to 77.9°. Furthermore, the ANB angle changed from -9.8° to 1.6° and the occlusion changed from Class III to Class I. The profile of the face changed from concave to convex and a much better esthetic result was achieved. The study suggests RED system to be a reliable alternative procedure for the treatment of midfacial hypoplasia with or without cleft. Furthermore, it minimizes the risk of the surgical procedure and shortens the operating time.

  8. Prosthetic rehabilitation of an edentulous maxilla with microstomia, limited interarch space, and malaligned implants: a clinical report.

    Science.gov (United States)

    Turkyilmaz, Ilser

    2012-04-01

    Although dental implant treatment is a very successful option today, a meticulous treatment planning and close collaboration between the oral surgeon and restorative doctor is crucial to eliminate undesired outcomes. To present a challenging case restored with a maxillary screw-retained fixed prosthesis using malpositioned/malaligned implants. A 47-year-old female had a Lefort I fracture and lost all maxillary teeth due to traumatic injury in a traffic accident. Seven maxillary implants were placed using a 1-stage surgical approach, 6 months after open reduction surgery in a private practice. Radiographic and clinical evaluation indicated marginal bone loss around 3 anterior implants. The malposition and malalignment of implants made impression and casting procedures very complicated. The other challenging factors with this patient were microstomia, limited mouth opening due to scar tissue from previous plastic surgery, and a very small maxilla. The 1-piece metal framework did not fit accurately so it was sectioned into 3 segments. The 3 separate segments were screwed on the abutments individually, then connected to each other using an acrylic resin. The 3 framework segments were laser welded. After the laser welding, a passive fit of the framework was achieved. It has been suggested that providing an implant treatment to a patient with implants placed in wrong positions with undesired angulations can be very difficult. Also, laser welding may be a viable option to eliminate misfit of full-arch metal frameworks.

  9. Minimum Abutment Height to Eliminate Bone Loss: Influence of Implant Neck Design and Platform Switching.

    Science.gov (United States)

    Spinato, Sergio; Galindo-Moreno, Pablo; Bernardello, Fabio; Zaffe, Davide

    This retrospective study quantitatively analyzed the minimum prosthetic abutment height to eliminate bone loss after 4.7-mm-diameter implant placement in maxillary bone and how grafting techniques can affect the marginal bone loss in implants placed in maxillary areas. Two different implant types with a similar neck design were singularly placed in two groups of patients: the test group, with platform-switched implants, and the control group, with conventional (non-platform-switched) implants. Patients requiring bone augmentation underwent unilateral sinus augmentation using a transcrestal technique with mineralized xenograft. Radiographs were taken immediately after implant placement, after delivery of the prosthetic restoration, and after 12 months of loading. The average mesial and distal marginal bone loss of the control group (25 patients) was significantly more than twice that of the test group (26 patients), while their average abutment height was similar. Linear regression analysis highlighted a statistically significant inverse relationship between marginal bone loss and abutment height in both groups; however, the intercept of the regression line, both mesially and distally, was 50% lower for the test group than for the control group. The marginal bone loss was annulled with an abutment height of 2.5 mm for the test group and 3.0 mm for the control group. No statistically significant differences were found regarding marginal bone loss of implants placed in native maxillary bone compared with those placed in the grafted areas. The results suggest that the shorter the abutment height, the greater the marginal bone loss in cement-retained prostheses. Abutment height showed a greater influence in platform-switched than in non-platform-switched implants on the limitation of marginal bone loss.

  10. Evaluation of single-tooth implants in the second molar region: a 5-year life-table analysis of a retrospective study.

    Science.gov (United States)

    Koo, Ki-Tae; Wikesjö, Ulf M E; Park, Jang-Yeol; Kim, Tae-Il; Seol, Yang-Jo; Ku, Young; Rhyu, In-Chul; Chung, Chong-Pyoung; Lee, Yong-Moo

    2010-09-01

    To our knowledge, no study has evaluated the success or survival rate of single-tooth implants that replaced missing maxillary and mandibular second molars. The purpose of the present study was to evaluate the 1- to 5-year cumulative survival rate (CSR) for single-tooth implants placed in the second molar region and the effects of associated factors. Four hundred eighty-nine patients (298 males and 191 females; age range: 23 to 91 years; mean age: 47 years) who were admitted to the Seoul National University Dental Hospital between March 2003 and July 2008 and treated with single-tooth implants in the second molar region (227 maxillary implants and 294 mandibular implants; total: 521 implants) were included in the study. Thirty-two subjects received two implants each. A 1- to 5-year CSR was calculated using a life-table analysis. A comparison of CSRs between maxillary versus mandibular implants, one-stage versus two-stage implants, short (10 mm) implants, and standard-diameter (or=5.0 mm) implants was performed using Wilcoxon (Gehan) statistics. P CSR was 95.1%. There were no statistically significant differences in CSRs between implants placed in maxillas and mandibles (96.3% versus 94.9%, respectively; P = 0.084), one- and two-stage implants (95.6% versus 94.7%, respectively; P = 0.267), short and long implants (100% versus 95.1%, respectively; P = 0.582), and standard- and wide-diameter implants (93.8% versus 96.8%, respectively; P = 0.065). Within the limitations of the study, the placement of single-tooth implants in the second molar region was an effective and reliable treatment modality. Also, associated factors such as implant diameter, length, and location (the maxilla versus the mandible) may not have an impact on the long-term success of implants.

  11. Skeletal and dental stability after maxillary distraction with a rigid external device in adult cleft lip and palate patients.

    Science.gov (United States)

    Aksu, Muge; Saglam-Aydinatay, Banu; Akcan, Cenk Ahmet; El, Hakan; Taner, Tulin; Kocadereli, Ilken; Tuncbilek, Gokhan; Mavili, Mehmet Emin

    2010-02-01

    To evaluate skeletal and dental stability in adult cleft lip and palate patients treated with a rigid external distraction system at the end of distraction and during the postdistraction period. Lateral cephalograms of 7 patients were obtained before distraction, at the end of distraction, and during the postdistraction period. The mean age before distraction was 21.56 +/- 4.73 years. The mean follow-up was 37.3 +/- 12.4 months. The assessment of findings showed that skeletal maxillary sagittal movement was achieved in a superoanterior direction. The maxillary depth angle and effective maxillary length increased significantly (2 degrees and 9 mm, respectively) after distraction, whereas the palatal plane angle increased by 8 degrees , resulting in an anterior movement of the maxilla with a counterclockwise rotation. The lower facial height showed no significant changes after distraction. The sagittal movement of the upper incisors and the angulation of the upper first molars increased significantly (4.5 mm and 5.5 degrees , respectively). During the postdistraction period, the maxilla showed a slight relapse (22%). The effective maxillary length decreased by 2 mm. The palatal plane angle almost returned to its original position, showing 7 degrees of clockwise rotation. The lower facial height remained stable. The upper incisors moved anteriorly and the upper first molars showed a significant mesioangular change during follow-up. After distraction, significant maxillary advancement was achieved with a counterclockwise rotation. The upper incisors moved labially, and the upper first molars angulated mesially. After 3 years, a 22% relapse rate was seen in the maxilla. The counterclockwise rotation of the maxilla was returned to its original position. The upper incisors moved more anteriorly. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Complete overdentures retained by mini implants: A systematic review.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  13. THE EFFECTS OF MAXILLARY EXPANSION ON THE SOFT TISSUE FACIAL PROFILE

    Directory of Open Access Journals (Sweden)

    Işıl ARAS

    2017-10-01

    Full Text Available Purpose: The aims of this retrospective study were to evaluate the possible changes in soft tissue facial profile induced by orthopedic rapid maxillary expansion (RME and surgically assisted rapid maxillary expansion (SARME, and to correlate them with the underlying hard tissue alterations. Materials and Methods: 16 patients who received bone borne SARME and 25 patients who were subjected to RME using metal cast splint hyrax appliance were analyzed retrospectively. This research was conducted on lateral cephalometric radiographs taken on 2 occasions: before expansion (T1 and at the beginning of any further orthodontic treatment (T2. Investigated lateral cephalometric parameters consisted of Holdaway soft tissue measurements with some supplementary soft tissue, skeletal and dental assessments. Results: The acquisition of T2 cephalograms which conforms to the initiation of further orthodontic treatment corresponded to 83.25±3.51 days for SARME and 85.68±4.37 days for RME after the expansion was completed. The only significant change in soft tissue profile of the SARME group was a decrease in upper lip thickness (p<0.05, whereas in the RME group, decrease in soft tissue facial profile angle and increase in H angle were found to be statistically significant (p<0.05 for each. For the RME group, the changes in soft tissue facial profile angle and H angle correlated only with the changes in SNB angle (p<0.05. Conclusion: While bone-borne SARME did not seem to possess the potential to alter soft tissue profile, tooth-borne RME caused a more convex soft tissue profile related to a reduction in SNB.

  14. Reconstruction of the maxilla following hemimaxillectomy defects with scapular tip grafts and dental implants.

    Science.gov (United States)

    Mertens, Christian; Freudlsperger, Christian; Bodem, Jens; Engel, Michael; Hoffmann, Jürgen; Freier, Kolja

    2016-11-01

    Treatment of post-resective defects of the maxilla can be challenging and usually requires dental obturation or microvascular reconstruction. As compared to soft-tissue microvascular grafts, bone reconstruction can additionally allow for facial support and retention of dental implants. The aim of this study was to evaluate scapular tip grafts with respect to their applicability for maxillary reconstruction and their potential to retain dental implants for later dental rehabilitation. In this retrospective study, 14 patients with hemimaxillectomy defects were reconstructed with free scapular tip grafts, oriented horizontally, to rebuild the palate and alveolar ridge. After bone healing, three-dimensional virtual implant planning was performed, and a radiographic guide was fabricated to enable implant placement in the optimal anatomic and prosthetic position. All patients' mastication and speech were evaluated, along with the extent of defect closure, suitability of the graft sites for implant placement, and soft-tissue stability. Pre- and postsurgical radiographs were also evaluated. A good postoperative outcome was achieved in all patients, with complete closure of maxillary defects that were class II, according to the system of Brown and Shaw. Additional bone augmentation was necessary in two patients in order to increase vertical bone height. Patients were subsequently treated with 50 dental implants to retain dental prostheses. In all cases, additional soft-tissue surgery was necessary to achieve a long-term stable periimplant situation. No implants were lost during the mean observation period of 34 months. Due to its specific form, the scapular tip graft is well suited to reconstruct the palate and maxillary alveolar ridge and to enable subsequent implant-retained rehabilitation. Due to the limited bone volume, an accurate three-dimensional graft orientation is essential. Furthermore, most cases require additional soft-tissue surgery to achieve a long

  15. Velopharyngeal changes after maxillary distraction in cleft patients using a rigid external distraction device: A retrospective study.

    Science.gov (United States)

    Taha, Mahasen; Elsheikh, Yasser M

    2016-11-01

     To evaluate early and late velopharyngeal changes in cleft lip and palate (CLP) patients after use of the Rigid External Distractor (RED) device and to correlate these changes to the amount of maxillary advancement.  Thirty Class III CLP patients were included in the study. Maxillary advancement was performed using the RED device in combination with titanium miniplates and screws for anchorage. Lateral cephalograms, nasometer, and nasopharyngoscope records were taken before distraction, immediately after distraction, and 1 year after distraction. A paired t-test was used to detect differences at P maxillary distraction (P  =  .0001). Statistically significant increases in nasopharyngeal and oropharyngeal depths, velar angle, and need ratio were also found (P  =  .0001). Nasalance scores showed a significant increase (P  =  .008 for nasal text and .044 for oral text). A significant positive correlation was observed between the amount of maxillary advancement and the increase in nasopharyngeal depth and hypernasality (P  =  .012 and .026, respectively).  Nasopharyngeal function was deteriorated after maxillary advancement in CLP patients. There was a significant positive correlation between the amount of maxillary advancement and the increase in nasopharyngeal depth and hypernasality.

  16. Truncal anaesthesia of the maxillary nerve for outpatient surgically assisted rapid maxillary expansion.

    Science.gov (United States)

    Robiony, M; Demitri, V; Costa, F; Politi, M; Cugini, U

    1998-10-01

    We present our experience of transcutaneous truncal anaesthesia of the maxillary nerve in association with transmucosal anaesthesia of the sphenopalatine ganglion in surgically assisted rapid maxillary expansion. Twelve patients with a skeletal transverse discrepancy of the maxilla were treated in our department from 1994 to 1995. Maxillary transcutaneous nerve block was done with a Quincke 8 cm spinal needle together with transmucosal anaesthesia of the sphenopalatine ganglion. Mepivacaine without adrenaline and sodium bicarbonate 1/10 was used for truncal anaesthesia and lidocaine-prilocaine cream for transmucosal anaesthesia. A Le Fort I osteotomy, lateral nasal wall osteotomy, pterygomaxillary osteotomy, and a palatal osteotomy were done for all patients before the maxillary expansion. Total anaesthesia of the maxillary area facilitated the operations and appreciably reduced the amount of postoperative pain. The ease of achieving effective anaesthesia before and after operation and the absence of side-effects make this form of anaesthetic particularly useful in surgically assisted rapid maxillary expansion.

  17. Maxillary hematocele

    International Nuclear Information System (INIS)

    Inaba, Tsuyoshi; Fujimura, Takeyuki; Udaka, Tsuyoshi; Siomori, Teruo; Kadokawa, Yohei; Suzuki, Hideaki

    2007-01-01

    Hematocele is a benign hemorrhagic pseudotumor that preferably arises in the sinonasal tract, particularly in the maxillary sinus. The occurrence of maxillary hematocele has sporadically been documented, but its nature is not dearly understood. We herein report four cases of maxillary hematocele. The patients were 3 men and one woman, 30-62 years of age with an average of 49.8 years. Major symptoms were nasal obstruction (2 cases), nasal bleeding (2 cases), and toothache (1 case). Computed tomography demonstrated well-defined expansive soft tissue shadows with bone erosion. The lesions showed intermingled high/intermediate/low intensity in both T1- and T2-weighted magnetic resonance imaging. Endoscopic sinus surgery was performed in 3 cases, and the other patient underwent Caldwell-Luc procedure. Surgical specimens microscopically exhibited inflammatory changes with hematoma and fibrin deposition. The postoperative clinical course was uneventful in all cases, and all the patients are currently free from disease 4-25 months after surgery. Clinical, histopathological and radiological characteristics of maxillary hematocele are reviewed. (author)

  18. The Immediate Aesthetic and Functional Restoration of Maxillary Incisors Compromised by Periodontitis Using Short Implants with Single Crown Restorations: A Minimally Invasive Approach and Five-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Mauro Marincola

    2015-01-01

    Full Text Available The functional and aesthetic restoration of teeth compromised due to aggressive periodontitis presents numerous challenges for the clinician. Horizontal bone loss and soft tissue destruction resulting from periodontitis can impede implant placement and the regeneration of an aesthetically pleasing gingival smile line, often requiring bone augmentation and mucogingival surgery, respectively. Conservative approaches to the treatment of aggressive periodontitis (i.e., treatments that use minimally invasive tools and techniques have been purported to yield positive outcomes. Here, we report on the treatment and five-year follow-up of patient suffering from aggressive periodontitis using a minimally invasive surgical technique and implant system. By using the methods described herein, we were able to achieve the immediate aesthetic and functional restoration of the maxillary incisors in a case that would otherwise require bone augmentation and extensive mucogingival surgery. This technique represents a conservative and efficacious alternative to the aesthetic and functional replacement of teeth compromised due to aggressive periodontitis.

  19. Volumetric changes of the graft after maxillary sinus floor augmentation with Bio-Oss and autogenous bone in different ratios

    DEFF Research Database (Denmark)

    Jensen, Thomas; Schou, Søren; Svendsen, Patricia Anne

    2012-01-01

    composition was selected at random and placed concomitant with implant placement. Computed tomographies of the maxillary sinuses were obtained preoperatively, immediately postoperatively, and at euthanasia after 12 weeks. The volumetric changes of the graft were estimated using the Cavalieri principle...

  20. Maxillary molar distalization with first class appliance.

    Science.gov (United States)

    Ramesh, Namitha; Palukunnu, Biswas; Ravindran, Nidhi; Nair, Preeti P

    2014-02-27

    Non-extraction treatment has gained popularity for corrections of mild-to-moderate class II malocclusion over the past few decades. The distalization of maxillary molars is of significant value for treatment of cases with minimal arch discrepancy and mild class II molar relation associated with a normal mandibular arch and acceptable profile. This paper describes our experience with a 16-year-old female patient who reported with irregularly placed upper front teeth and unpleasant smile. The patient was diagnosed to have angles class II malocclusion with moderate maxillary anterior crowding, deep bite of 4 mm on a skeletal class II base with an orthognathic maxilla and retrognathic mandible and normal growth pattern. She presented an ideal profile and so molar distalization was planned with the first-class appliance. Molars were distalised by 8 mm on the right and left quadrants and class I molar relation achieved within 4 months. The space gained was utilised effectively to align the arch and establish a class I molar and canine relation.

  1. Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer.

    Science.gov (United States)

    Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui

    2015-01-01

    To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.

  2. Orthodontic intrusion : Conventional and mini-implant assisted intrusion mechanics

    Directory of Open Access Journals (Sweden)

    Anup Belludi

    2012-01-01

    intrusion has revolutionized orthodontic anchorage and biomechanics by making anchorage perfectly stable. This article addresses various conventional clinical intrusion mechanics and especially intrusion using mini-implants that have proven effective over the years for intrusion of maxillary anteriors.

  3. Influence of mandibular fixation method on stability of the maxillary occlusal plane after occlusal plane alteration.

    Science.gov (United States)

    Yosano, Akira; Katakura, Akira; Takaki, Takashi; Shibahara, Takahiko

    2009-05-01

    In this study, we investigated how method of mandibular fixation influenced longterm postoperative stability of the maxilla in Class III cases. In particular, we investigated change in the maxillary occlusal plane after Occlusal Plane Alteration. Therefore, we focused on change in the palatal plane to evaluate stability of the maxillary occlusal plane, as the position of the palatal plane affects the maxillary occlusal plane. This study included 16 patients diagnosed with mandibular protrusion. Alteration of the occlusal plane was achieved by clockwise rotation of the maxilla by Le Fort I osteotomy and mandibular setback was performed by bilateral sagittal split ramus osteotomy. We analyzed and examined lateral cephalometric radiographs taken at 1 month, 3 months, 6 months, and 1 year after surgery. Stability achieved by two methods of mandibular fixation was compared. In one group of patients (group S) titanium screws were used, and in the other group (group P) titanium-locking mini-plates were used. No significant displacement was recognized in group S, whereas an approximately 0.7mm upward vertical displacement was recognized in the anterior nasal spine in group P. As a result, not only the angle of the palatal plane and S-N plane, but also occlusal plane angle in group P showed a greater decrease than that in group S. The results suggest that fixing the mandible with screws yielded greater stability of the maxilla and maxillary occlusal plane than fixing the mandible with titanium plates.

  4. The resection angle in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Janner, Simone F M; Jensen, Simon S

    2016-01-01

    OBJECTIVES: The primary objective of the present radiographic study was to analyse the resection angle in apical surgery and its correlation with treatment outcome, type of treated tooth, surgical depth and level of root-end filling. MATERIALS AND METHODS: In the context of a prospective clinical...... study, cone beam computed tomography (CBCT) scans were taken before and 1 year after apical surgery to measure the angle of the resection plane relative to the longitudinal axis of the root. Further, the surgical depth (distance from the buccal cortex to the most lingual/palatal point of the resection...... or with the retrofilling length. CONCLUSIONS: Statistically significant differences were observed comparing resection angles of different tooth groups. However, the angle had no significant effect on treatment outcome. CLINICAL RELEVANCE: Contrary to common belief, the resection angle in maxillary anterior teeth...

  5. Full Mouth Reconstruction of a Skeletal Class II Division 1 Patient with Adenoid Cystic Carcinoma Using an Interim Immediate Obturator and a Definitive Obturator

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-01-01

    Full Text Available A 61-year-old female patient with adenoid cystic carcinoma (ACC of the right maxilla and Angle class II division 1 malocclusion had received a subtotal maxillectomy in right side and used a conventional clasp-retained obturator. After implants placement, a maxillary interim immediate obturator (IIO and then a definitive obturator using six endosseous implants were fabricated. During one-year follow-up, the patient was completely satisfied. Ideally, after implants placement in edentulous patients suffering from hemimaxillectomy, an implant-supported obturator (ISO is designed in order to prevent nasal reflux and to improve speech and swallowing. However, in the following case, because of skeletal class II division 1 malocclusion and implants insertion in the premaxilla, using an ISO was impossible because it would cause excessive upper lip protrusion and lack of anterior teeth contact. Therefore, a five-unit implant-supported fixed partial denture (FPD was fabricated in the maxillary anterior segment so that anterior teeth contacts were possible and the patient’s normal lip support was achieved. A bar and three ball attachments were used in the maxillary posterior segment. A closed-hollow-bulb ISO was preferred. Conventional ISO in these patients results in several problems. Using a maxillary anterior FPD along with ISO caused satisfactory results in the current patient.

  6. Missing upper incisors: a retrospective study of orthodontic space closure versus implant.

    Science.gov (United States)

    Jamilian, Abdolreza; Perillo, Letizia; Rosa, Marco

    2015-02-25

    The aim of this retrospective study was to compare the esthetic, periodontal, and functional outcomes of orthodontic space closure versus implant substitution in patients with missing maxillary incisors 5 years after completion of treatment. The study group consisted of ten patients treated with orthodontic space closure (six males, four females, mean age 19 ± 2.1 years at the completion of treatment) and ten patients treated with implant insertion (five males, five females, mean age 20 ± 1.4 years at the time of implant insertion). Tooth mobility, plaque index, probing depth, infraocclusion, open gingival embrasure (black triangle), and temporomandibular joint function were recorded at the 5.6 years follow-up. Self-perceived dental esthetic appearance was also evaluated through a visual analog scale (VAS) questionnaire. T-test was used to evaluate the data. All patients were equally satisfied with the appearance of their teeth 5.6 ± 0.4 years after the completion of treatment. No statistically significant differences were found in relation to the VAS scores of the subjects (P Orthodontic space closure and implant of missing maxillary incisors produced similar, well-accepted esthetic results. None of the treatments impaired temporomandibular joint function. Nevertheless, infraocclusion was evident in implant patients. Space closure patients also showed better periodontal health in comparison with implant patients.

  7. Alteration of maxillary and mandibular growth of adult patients with unoperated isolated cleft palate.

    Science.gov (United States)

    Yang, Yunqiang; Wu, Yeke; Gu, Yifei; Yang, Qijian; Shi, Bing; Zheng, Qian; Wang, Yan

    2013-07-01

    The objective of this study was to investigate the effects of cleft palate itself on the growth of maxilla and mandible. Fifty-two adult female patients with unoperated isolated cleft palate and 52 adult female individuals with normal occlusion were included in our study. Computer software was used for lateral cephalometry measurement. Manual measurement was performed for dental cast measurements, and sample t test analysis was applied to analyze the differences between the 2 groups using SPSS 17.0. The sella-nasion-subspinale point angle, subspinale-nasion-supramentale point angle, and maxillary arch length of the cleft group were significantly smaller than those of the control group (P cleft group were significantly larger compared with the control group (P palate height, and palate shelf inclination did not differ between the 2 groups. The measurements did not differ between the submucosal cleft and the overt cleft patients. Cleft palate itself has adverse effects on the maxilla growth with shorter maxillary arch length and wider posterior dental arch width.

  8. Effect of Porous Titanium Granules on Bone Regeneration and Primary Stability in Maxillary Sinus: A Human Clinical, Histomorphometric, and Microcomputed Tomography Analyses.

    Science.gov (United States)

    Dursun, Ceyda Kanli; Dursun, Erhan; Eratalay, Kenan; Orhan, Kaan; Tatar, Ilkan; Baris, Emre; Tözüm, Tolga Fikret

    2016-03-01

    The aim of this randomized controlled study was to comparatively analyze the new bone (NB), residual bone, and graft-bone association in bone biopsies retrieved from augmented maxillary sinus sites by histomorphometry and microcomputed tomography (MicroCT) in a split-mouth model to test the efficacy of porous titanium granules (PTG) in maxillary sinus augmentation. Fifteen patients were included in the study and each patient was treated with bilateral sinus augmentation procedure using xenograft (equine origine, granule size 1000-2000 μm) and xenograft (1 g) + PTG (granule size 700-1000 μm, pore size >50 μm) (1 g), respectively. After a mean of 8.4 months, 30 bone biopsies were retrieved from the implant sites for three-dimensional MicroCT and two-dimensional histomorphometric analyses. Bone volume and vital NB percentages were calculated. Immediate after core biopsy, implants having standard dimensions were placed and implant stability quotient values were recorded at baseline and 3 months follow-up. There were no significant differences between groups according to residual bone height, residual bone width, implant dimensions, and implant stability quotient values (baseline and 3 months). According to MicroCT and two-dimensional histomorphometric analyses, the volume of newly formed bone was 57.05% and 52.67%, and 56.5% and 55.08% for xenograft + PTG and xenograft groups, respectively. No statistically significant differences found between groups according to NB percentages and higher Hounsfield unit values were found for xenograft + PTG group. The findings of the current study supports that PTG, which is a porous, permanent nonresorbable bone substitute, may have a beneficial osteoconductive effect on mechanical strength of NB in augmented maxillary sinus.

  9. Establishing the maxillary occlusal plane as a requisite for placement of an immediate implant-supported fixed prosthesis in the mandible: a case report

    Directory of Open Access Journals (Sweden)

    Milton Edson Miranda

    Full Text Available INTRODUCTION: In patients with Bruxism, the attrition can result in excessive occlusal wear that exceeds the compensatory mechanism and loss of occlusion vertical dimension occurs. OBJECTIVE: The purpose of this article is to show the importance of re-establishing an adequate occlusal plane for the non treated arch by means of a fixed acrylic overlay, compatible with the prosthetic treatment of the arch to be rehabilitated. An upper maxillary fixed acrylic overlay restored the patient’s occlusal plane in an appropriate vertical dimension of occlusion together with a fixed prosthesis in the mandible, supported by five dental implants. CONCLUSION: When there is severe wear due to dental attrition in one of the arches, it is important to re-establish the occlusal plane and compensation curves in conjunction with the prosthetic treatment of the arch to be rehabilitated.

  10. Alternativas a la elevación de seno maxilar: implantes cortos Alternatives to maxillary sinus elevation: short implants

    Directory of Open Access Journals (Sweden)

    J. González Lagunas

    2008-12-01

    Full Text Available La mala calidad del hueso, reabsorciones extremas y la presencia de la cavidad del seno maxilar constituían obstáculos insalvables para la rehabilitación implanto-soportada en el sector posterior del maxilar atrófico. La elevación de seno es probablemente la primera opción de tratamiento en el paciente tributario de rehabilitación con implantes en ese sector. El uso de implantes cortos (menos de 10 mm se ha asociado tradicionalmente con unas tasas de supervivencia menores que la de los implantes largos. No obstante la aparición de nuevas superficies y diseños indican que este tipo de implantes puede soportar de forma fiable restauraciones dentales. Presentamos la técnica de instalación de implantes de superficie porosa sinterizada, asi como una revisión actualizada sobre el comportamiento de los implantes cortos.Poor bone quality, extreme bony resorption and a pneumatized mqxillary sinus are a severe Challenger for reconstruction of the atrophic edentuous posterior maxilla. Sinus lift is probably the gold standard for Management of that area. Short implants (<10mm have traditionally been associated with lower survival rates. The introduction of new surfaces and designs indicate that this type of implants can adequately support dental restorations. We present the technique of installation of sinterised porous dental implants together with an update on the behaviour of short implants.

  11. Strain characteristics of Marburg double crown-retained implant overdentures compared with bar and ball-retained implant overdentures, with and without a rigid major connector.

    Science.gov (United States)

    Kazokoğlu, F Şehnaz; Akaltan, Funda

    2014-12-01

    It is hard to identify the most favorable retainer type and the denture design when considering strain levels around implants and in edentulous ridges for implant overdentures (IOVD). The purpose of this study was to evaluate the strain transmitted to the implants and edentulous ridges by Marburg double crown (MDC)-retained IOVD as opposed to bar and ball-retained IOVD and the efficiency of a rigid major connector in the maxilla. An in vitro maxillary model was prepared with 4 implants, with strain gauges placed distally to each implant and also in the anterior and posterior edentulous ridges. Five overdentures were fabricated for each MDC and each ball and bar attachment retainers. Vertical loads of 280 N were applied bilaterally on the first molar region. Then the palatal bars of each IOVD were disconnected, and loading procedures were repeated for the prostheses. No significant difference was observed among the MDC and the bar and ball-retained IOVD, with and without a rigid bar according to the data taken from both the implants and edentulous ridges. However, when the strain values attained from each strain gauge separately were considered, a slight difference was observed around the implants of ball-retained overdentures and in the edentulous ridges of MDC-retained overdentures. Within the limitations of this in vitro study, MDC-retained maxillary overdentures with 4 parallel and symmetrically placed implants can be used safely without a rigid major connector as with bar and ball-retained IOVD with regard to the strains generated in the edentulous ridge and around implants. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Role of Cone Beam Computed Tomography in Rehabilitation of a Traumatised Deficient Maxillary Alveolar Ridge Using Symphyseal Block Graft Placement

    Directory of Open Access Journals (Sweden)

    Shipra Arora

    2013-01-01

    Full Text Available Deficiencies in the alveolar ridges cause multiple problems in achieving aesthetic and functional outcome of implant therapy and are commonly restored by using onlay graft from intraoral source. Careful assessment of the recipient as well as the donor site using cone beam computed tomography (CBCT is a prerequisite to ideal treatment planning. This paper highlights the critical role of CBCT in planning a successful rehabilitation of traumatised deficient anterior maxillary alveolar ridge using autogenous block graft from mandibular symphysis, followed by implant placement. A 21-year-old male reported with missing right maxillary lateral incisor due to traumatic avulsion 6 months back. A concavity was found on the labial aspect of edentulous area. Serial transplanar images on CBCT revealed gross irregular radiolucency in place of labial cortical plate. Using CBCT, size of the required block was estimated, and mandibular symphyseal area was evaluated for the feasibility of harvesting a graft of suitable dimension. Onlay block graft was harvested from mandibular symphysis and placed at the edentulous site to augment the alveolar ridge. Implants were placed 5 months later and loaded successfully after osseointegration. After 1 year of followup, implant-based prosthesis is working well, without any complications.

  13. Alternativas a la elevación de seno maxilar: rehabilitación del sector posterior del maxilar atrófico mediante implantes pterigoideos Alternatives to maxillary sinus lift: posterior area of the atrophic maxilla rehabilitation by means pterigoideal implants

    Directory of Open Access Journals (Sweden)

    X. Rodríguez-Ciurana

    2008-12-01

    Full Text Available El primer y segundo molar son los dientes que se pierden más a menudo debido a la enfermedad periodontal y al exceso de fuerzas oclusales. A pesar de la frecuencia del edentulismo parcial del sector posterior raramente se ubican los implantes más allá de los premolares debido al aumento del índice de fallos. El escaso volumen óseo y la pobre mineralización del sector posterior del maxilar comprometen la viabilidad de las rehabilitaciones con implantes a largo plazo. Además, la cresta ósea a nivel del seno maxilar, en el maxilar atrófico, no suele permitir el anclaje de implantes de 10 mm. Se han propuesto varias técnicas para rehabilitar el sector posterior del maxilar atrófico: implantes cortos, extensiones protésicas, injerto sinusal, implante cigomático. El implante pterigoideo es otro de los posibles tratamientos para rehabilitar el sector posterior del maxilar atrófico. Anclado en el hueso cortical de la apófisis del esfenoides el implante pterigoideo evita la necesidad de injertar o utilizar extensiones protésicas. El objetivo de este artículo es analizar las indicaciones, la técnica, complicaciones y supervivencia del implante pterigoideo en el sector posterior del maxilar atrófico.The first and second molar are the teeth most commonly lost in the maxilla, mainly due to periodontal disease and excessive occlusal force. 1 Although partial edentulism of the posterior maxilla is common, implants are seldom placed distal to the premolars because failure rates in the posterior maxilla have historically been high. Poor volume and low density of bone are the worst conditions for long-term anchorage in the maxilla. 7 Moreover, bone under the maxillary sinus, in the atrophic maxilla, is usually insufficient to enable placement of 10 mm implants. Several techniques have been proposed to restore the atrophic posterior maxilla: short implants, prosthetic cantilevers, sinus bone graft, zigomatic fixtures. Pterygoid implants are

  14. Effects of pelvic rotation and needle angle on pubic arch interference during transperineal prostate implants

    International Nuclear Information System (INIS)

    Tincher, Sandra A.; Kim, Robert Y.; Ezekiel, Mark P.; Zinsli, Tom; Fiveash, John B.; Raben, David A.; Bueschen, Anton J.; Urban, Donald A.

    2000-01-01

    Purpose: Pubic arch interference due to an enlarged prostate gland or a narrow pubic arch is often a limiting factor in adequate prostate coverage during transperineal brachytherapy. The purpose of this study was to evaluate the effects of both pelvic rotation and needle angles on pubic arch interference using CT-based 3-D information. Methods and Materials: Seven patients had CT imaging in both supine and lithotomy positions and 3-D treatment planning was performed with three needle angles (20 downward, 0, 20 upward). The pubic arch interference was then measured and comparisons were made for each needle trajectory and pelvic position. Results: Increasing pelvic rotation from supine to lithotomy position shows less pubic arch interference. Directing the needle tip upward shows less pubic arch interference in both supine and lithotomy positions when compared to needle tips directed downward. Conclusions: Both pelvic position and needle angles are important factors influencing pubic arch interference. Preplanning CT-based 3-D information may assist for individualized treatment planning in patients with a significant bony interference, thus avoiding pubic arch interference during implantation

  15. Systematic Review of Soft Tissue Alterations and Esthetic Outcomes Following Immediate Implant Placement and Restoration of Single Implants in the Anterior Maxilla.

    Science.gov (United States)

    Khzam, Nabil; Arora, Himanshu; Kim, Paul; Fisher, Anthony; Mattheos, Nikos; Ivanovski, Saso

    2015-12-01

    The aim of this review is to assess the outcome of single-tooth immediate implant placement and restoration (IPR) in the maxillary anterior region, with a particular emphasis on soft tissue and esthetic outcomes. An electronic search in Medline, EBSCOhost, and Ovid (PubMed) was performed to identify studies that reported on soft tissue outcomes following immediate placement and restoration of implants in the maxillary esthetic region with a mean follow-up of ≥1 year. Nineteen studies on single implants inserted immediately into fresh extraction sockets and provisionally restored in the maxillary esthetic region were included. Soft tissue changes were found to be acceptable, with most studies reporting mean gingival recession of 0.27 ± 0.38 mm and mean papillary height loss of 0.23 ± 0.27 mm after follow-up of ≥1 year. Advanced buccal recession (>1 mm) occurred in 11% of cases. Long-term follow-up studies (>2 years) reported that the interdental papillae, in particular, showed a tendency to rebound over time. The few studies that reported on patient-centered outcomes showed a high level of patient satisfaction with the outcomes of IPR treatment. The IPR protocol resulted in generally acceptable soft tissue and esthetic outcomes, with suboptimal results reported in ≈11% of low-risk cases. Factors such as preoperative tissue biotype or use of a flap or connective tissue graft did not significantly influence soft tissue and esthetic outcomes. Long-term prospective controlled clinical trials are necessary to identify factors that may influence the esthetic outcomes associated with IPR.

  16. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    Science.gov (United States)

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.

  17. Zygoma implants in oral rehabilitation: A review of 28 cases.

    Science.gov (United States)

    Agbara, Rowland; Goetze, Elizabeth; Koch, Felix; Wagner, Wilfred

    2017-01-01

    The functional and esthetic rehabilitation of patients with atrophic maxilla or posterior maxillary defect is often challenging. The aim of this study was to determine patient demographics, indications, success rate, and complications following the use of zygoma implants. All patients who had zygoma implant placement in our clinic between 1998 and 2013 were retrospectively assessed for implant outcome. Data were analyzed using Statistical Package for the Social Sciences (SPSS) version 16 and Microsoft Excel 2007 test for significance (ρ) using Pearson's Chi-square (χ 2 ) set at 0.05. A total of 28 patients consisting of 22 females (78.6%) and 6 males (21.4%) were treated, and their age ranged from 41 years to 83 years with a mean age of 60.3 ± 10.6 years. The main indication for zygoma implant placement was atrophic maxilla 12 (42.9%). In the prosthetic rehabilitation of the patients, 2 had epithetic prostheses, and 2 had obturators while 18 patients had conventional removable dental prostheses. Four patients (14.3%) had perimplantitis and one implant was accidentally placed into the maxillary sinus. A cumulative success rate of 88.1% was obtained from this retrospective analysis. A cumulative success rate of 88.1% reported in this study is lower than the reports from other studies. The difference in success rates may be related to different criteria for assessment of zygoma implant success and to the difference in inclusion criteria and follow-up period.

  18. The application of low angle Rutherford backscattering and channelling techniques to determine implantation induced disorder profile distributions in semiconductors

    International Nuclear Information System (INIS)

    Ahmed, N.A.G.; Christodoulides, C.E.; Carter, G.; Nobes, M.J.; Titov, A.I.

    1980-01-01

    Low angle exit (9 0 ) Rutherford backscattering geometry and channelling of 2 MeV 4 He + are employed to investigate the disorder depth profiles created by 40 keV N + implantation in (111) silicon and (100) GaAs targets. Parameters which can influence the disordering rate and its spatial distribution, such as ion fluence flux, substrate type and substrate temperature are examined. Under certain implantation conditions, the damage profile distributions are asymmetric - exhibiting a bimodal form in silicon targets or confined much closer to the GaAs surface than the normally expected mean range of 40 keV N + ions. (orig.)

  19. Management of Cleft Maxillary Hypoplasia with Anterior Maxillary Distraction: Our Experience.

    Science.gov (United States)

    Chacko, Tojan; Vinod, Sankar; Mani, Varghese; George, Arun; Sivaprasad, K K

    2014-12-01

    Maxillary hypoplasia is a common developmental problem in cleft lip and palate deformities. Since 1970s these deformities have traditionally been corrected by means of orthognathic surgery. Management of skeletal deformities in the maxillofacial region has been an important challenge for maxillofacial surgeons and orthodontists. Distraction osteogenesis is a surgical technique that uses body's own repairing mechanisms for optimal reconstruction of the tissues. We present four cases of anterior maxillary distraction osteogenesis with tooth borne distraction device-Hyrax, which were analyzed retrospectively for the efficacy of the tooth borne device-Hyrax and skeletal stability of distracted anterior maxillary segment.

  20. Immediate placement and restoration of dental implants in the esthetic region: clinical case series.

    Science.gov (United States)

    Khzam, Nabil; Mattheos, Nikos; Roberts, David; Bruce, William L; Ivanovski, Saso

    2014-01-01

    The objective of this study was to assess the hard and soft tissue changes following immediate placement and provisional restoration of single-tooth implants in the aesthetic zone. Thirteen patients with immediately placed and restored implants were included in this study. All participating patients underwent the same treatment strategy that involved removal of the failed tooth, flapless surgery, immediate implant placement, and connection of a screw-retained provisional restoration. Three months following implant placement, the temporary crowns were replaced by the definitive restorations. Implant survival rates, and hard and soft tissue changes were measured using periapical X-rays and photographs. The range of the observation period was between 12 and 37 months with a mean period of 23.2 ± 7.6 months. At the time of follow-up, all implants were present with no complications. Radiographic evaluation revealed a mean mesial bone gain of 1.20 ± 1.01 mm and a mean distal bone gain of 0.80 ± 1.14 mm, which reached statistical significance. The mean mid-buccal recession was 0.20 ± 0.78 mm, whereas the mesial and distal papillae height loss was 0.50 ± 1.26 mm and 0.30 ± 0.82 mm, respectively. The changes in the soft tissues did not reach statistical significance. Notwithstanding the limitation of a small sample size, this study shows that immediate implant placement and provisional restoration in the maxillary aesthetic zone can result in favorable treatment outcomes with regards to soft and hard tissues changes over a follow-up period of 23.2 ± 7.6 months. Most clinical trials investigating immediate implant placement and immediate restoration in the maxillary anterior zone have focused on implant survival and implant success, with particular emphasis on radiographically assessed hard tissues changes. However, this study assesses the soft tissue changes associated with this procedure, which is an important area of study

  1. Influence of implant rod curvature on sagittal correction of scoliosis deformity.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2014-08-01

    Deformation of in vivo-implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. To analyze the changes of the implant rod's angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. Twenty adolescent idiopathic scoliosis patients underwent surgery. Average age at the time of operation was 14 years. The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. Two implant rods were attached to the concave and convex side of the spinal deformity. The preoperative implant rod geometry was measured before surgical implantation. The postoperative implant rod geometry after surgery was measured by computed tomography. The implant rod angle of curvature at the sagittal plane was obtained from the implant rod geometry. The angle of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction. The difference between the postoperative implant rod angle of curvature and normal spine sagittal curvature of the corresponding instrumented level was used to evaluate over or under correction of the sagittal deformity. The implant rods at the concave side of deformity of all patients were significantly deformed after surgery. The average degree of rod deformation Δθ at the concave and convex sides was 15.8° and 1.6°, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6° and 17.8

  2. Orthodontic treatment of impacted maxillary canines: an appraisal of prognostic factors.

    Science.gov (United States)

    Baccetti, Tiziano; Crescini, Aldo; Nieri, Michele; Rotundo, Roberto; Pini Prato, Giovan Paolo

    2007-01-01

    The aim of the study was to evaluate the influence of pre-treatment radiographic features (alpha-angle, d-distance and s-sector) on the duration of active orthodontic traction of impacted maxillary canines treated by a combined surgical (flap approach) and orthodontic (direct traction to the center of the ridge) treatment. A study population of 168 patients (168 canines) was evaluated. Multiple regression analysis was used. Pre-treatment radiographic variables were associated significantly with the duration of orthodontic traction. Age, gender and site of impaction did not affect the duration of traction significantly. Alpha-angle, d-distance and s-sector are valid indicators for the duration of orthodontic traction.

  3. The zygomatic implant perforated (ZIP) flap: a new technique for combined surgical reconstruction and rapid fixed dental rehabilitation following low-level maxillectomy.

    Science.gov (United States)

    Butterworth, C J; Rogers, S N

    2017-12-01

    This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.

  4. ECG-derived spatial QRS-T angle is associated with ICD implantation, mortality and heart failure admissions in patients with LV systolic dysfunction.

    Directory of Open Access Journals (Sweden)

    Sarah Gleeson

    Full Text Available Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD therapy in patients with left ventricular systolic dysfunction (LVSD. We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF 31-40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention.534 patients ≤75 years of age with LVEF 31-40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes.49 patients (17% had events, defined as either mortality (n = 16 or ICD implantation for secondary prevention (n = 33. 72 parameters (58 A-ECG, 14 echocardiographic were univariately different (p110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4 for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9 for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease.Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.

  5. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  6. The Convergence Angle of Full-coverage Crown Preparations Made by Dental Students

    Directory of Open Access Journals (Sweden)

    R. Baghai Naini

    2008-03-01

    Full Text Available Objective: A clinically feasible convergence angle in full-coverage crown preparations, meeting the requirements for proper retention and resistance forms, has always been a matter of interest for laboratory and clinical researches. This study aims to evaluate the angle in teeth prepared by both under- and post-graduate students at Tehran University of Medical Sciences, Faculty of dentistry, Department of Prosthodontics.Materials and Methods: Samples consisted of 196 prepared teeth for full-coverage crown restoration by third year postgraduate and fifth year undergraduate students in the Department of Prosthodontics. Two images were obtained from each die by a scanner and both bucco-lingual and mesio-distal convergence angles were measured, by two different assessors, via Auto CAD 14 software. The data were analyzed using analysis of variance.Results: There were statistically significant differences between the teeth prepared by un-der- and post-graduate students in mesio-distal convergence angles of all maxillary teeth, except for canines. Significant differences were found between bucco-lingual convergence angles of the maxillary canines and molars.Conclusion: The recently recommended convergence angles are more clinically feasible compared to the classic 4 to 10 degrees that was previously suggested for all teeth. It also seems that clinical experience does not necessarily lead to a decrease in convergence an-gles during preparation.

  7. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

    Science.gov (United States)

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.

  8. Maxillary advancement for mandibular prognathism: indications and rationale.

    Science.gov (United States)

    Rosen, H M

    1991-05-01

    The surgical correction of mandibular prognathism has traditionally involved posterior repositioning of the mandibular body. This treatment approach corrects the skeletal disproportion at the expense of reducing facial skeletal volume and can unpredictably result in inadequately supported soft tissues with loss of skeletal definition. In an effort to avoid these sequelae of mandibular reduction, 18 patients diagnosed as having mandibular prognathism were treated with maxillary advancement surgery at the Le Fort I level. Mean patient SNB angle was 85.2 degrees, as compared with a normal 79 +/- 3 degrees. Maxillae were documented to be in normal position relative to both cranial base and Frankfort horizontal. The mean maxillary advancement was 6.9 mm, with a range of 4.5 to 8.8 mm. All patients required genioplasty to reduce vertical chin height and/or to laterally shift the chin. At the time of follow-up (mean 16.2 months), all patients retained cephalometric data suggestive of enlarged mandibles and excessive anterior facial divergence. However, maxillomandibular harmony and facial convexity had been restored without sacrificing skeletal volume. Treatment results demonstrated these faces to be skeletally well proportioned despite lower face protrusion that was beyond "normal." Postoperative appearances were characterized by a well-supported soft-tissue envelope and a highlighted skeletal foundation, creating angular, well-defined lower faces. These findings support the credibility of maxillary advancement as the procedure of choice in selected individuals with mandibular prognathism. Indications and an aesthetic rationale for this surgical approach are presented.

  9. Positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph

    International Nuclear Information System (INIS)

    Kim, Kyung Hwa; Koh, Kwang Joon

    2008-01-01

    To assess the positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (CBCT). CBCTs from 127 subjects were analysed. A total of 134 maxillary first molars were classified according to their vertical and horizontal positional relationship to the maxillary sinus floor and measured according to the distance between the maxillary sinus floor and the maxillary first molar. Type III (The root projected laterally on the sinus cavity but its apex is outside the sinus boundaries) was dominated between 10 and 19 years and type I (The root apex was not in contact with the cortical borders of the sinus) was dominated (P<0.05) between 20 and 72 years on the vertical relationship between the maxillary sinus floor and the apex of the maxillary first molar. The maxillary sinus floor was located more at the apex (78.2%) than at the furcation (21.3%) for the palatal root. The distance from the root apex to the maxillary sinus floor confined to type I was increased according to the ages (P<0.05). Type M (The maxillary sinus floor was located between the buccal and the palatal root) was most common (72.4%) on the horizontal relationship between the maxillary sinus floor and the apex of the maxillary first molar. CBCT can provide highly qualified images for the maxillary sinus floor and the root apex of the maxillary first molar.

  10. Simultaneous sinus lift and implantation using platelet-rich fibrin as sole grafting material.

    Science.gov (United States)

    Jeong, Seung-Mi; Lee, Chun-Ui; Son, Jeong-Seog; Oh, Ji-Hyeon; Fang, Yiqin; Choi, Byung-Ho

    2014-09-01

    Recently, several authors have shown that simultaneous sinus lift and implantation using autologous platelet-rich fibrin as the sole filling material is a reliable procedure promoting bone augmentation in the maxillary sinus. The aim of this study was to examine the effect of simultaneous sinus lift and implantation using platelet-rich fibrin as the sole grafting material on bone formation in a canine sinus model. An implant was placed after sinus membrane elevation in the maxillary sinus of six adult female mongrel dogs. The resulting space between the membrane and sinus floor was filled with autologous platelet-rich fibrin retrieved from each dog. The implants were left in place for six months. Bone tissue was seen at the lower part of the implants introduced into the sinus cavity. The height of the newly formed bone around the implants ranged from 0 mm to 4.9 mm (mean; 2.6 ± 2.0 mm) on the buccal side and from 0 mm to 4.2 mm (mean; 1.3 ± 1.8 mm) on the palatal side. The findings from this study suggest that simultaneous sinus lift and implantation using platelet-rich fibrin as sole grafting material is not a predictable and reproducible procedure, especially with respect to the bone formation around the implants in the sinus cavity. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. All rights reserved.

  11. Use of repeat anterior maxillary distraction to correct residual midface hypoplasia in cleft patients.

    Science.gov (United States)

    Richardson, Sunil; Krishna, Shreya; Bansal, Avi

    2017-12-01

    The study was designed to evaluate the efficacy of performing a second, repeat anterior maxillary distraction (AMD) to treat residual cleft maxillary hypoplasia. Five patients between the ages of 12 to 15 years with a history of AMD and with residual cleft maxillary hypoplasia were included in the study. Inclusion was irrespective of gender, type of cleft lip and palate, and the amount of advancement needed. Repeat AMD was executed in these patients 4 to 5 years after the primary AMD procedure to correct the cleft maxillary hypoplasia that had developed since the initial procedure. Orthopantomogram (OPG) and lateral cephalograms were taken for evaluation preoperatively, immediately after distraction, after consolidation, and one year postoperatively. The data obtained was tabulated and a Mann Whitney U-test was used for statistical comparisons. At the time of presentation, a residual maxillary hypoplasia was observed with a well maintained distraction gap on the OPG which ruled out the occurrence of a relapse. Favorable movement of the segments without any resistance was seen in all patients. Mean maxillary advancement of 10.56 mm was achieved at repeat AMD. Statistically significant increases in midfacial length, SNA angle, and nasion perpendicular to point A distance was achieved ( P =0.012, P =0.011, and P =0.012, respectively). Good profile was achieved for all patients. Minimal transient complications, for example anterior open bite and bleeding episodes, were managed. Addressing the problem of cleft maxillary hypoplasia at an early age (12-15 years) is beneficial for the child. Residual hypoplasia may develop in some patients, which may require additional corrective procedures. The results of our study show that AMD can be repeated when residual deformity develops with the previous procedure having no negative impact on the results of the repeat procedure.

  12. Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

    Science.gov (United States)

    Ferrario, Virgilio F; Tartaglia, Gianluca M; Maglione, Michele; Simion, Massimo; Sforza, Chiarella

    2004-04-01

    To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.

  13. Immediate Loading of Implants in the Edentulous Maxilla with a Fixed Provisional Restoration without Bone Augmentation: A Report on 5-Year Outcomes Data Obtained from a Prospective Clinical Trial.

    Science.gov (United States)

    Toljanic, Joseph A; Ekstrand, Karl; Baer, Russell A; Thor, Andreas

    2016-01-01

    Successful immediate loading of implants in the edentulous maxilla has been previously reported. The purpose of this 5-year prospective study was to further assess long-term outcomes following immediate loading of implants in the edentulous maxilla with fixed provisional restorations without the use of bone augmentation procedures. Subjects with edentulous maxillary arches each received six implants placed in native bone without augmentation. Where insufficient posterior bone volume existed, angled implant placement was employed. Fixed provisional restorations were delivered within 24 hours of implant placement. Implant placement locations, insertion torque values, and implant dimensions were recorded. Definitive fixed prostheses were placed within 24 weeks following implantation. Baseline implant site marginal bone levels were measured using periapical radiographs. Baseline peri-implant plaque and bleeding scores were obtained. Subjects were examined 6 months after implant placement and then annually for 5 years with follow-up periapical radiographs and plaque/bleeding scores obtained. Fifty-one subjects received a total of 306 implants. Forty subjects with 232 implants returned for the final follow-up appointment representing a 5-year implant survival proportion of 93% with a mean marginal bone loss of 0.44 ± 1.25 mm for this group. Thirty-nine of these 40 subjects continued to function with fixed restorations with the remaining subject functioning with a non-implant-retained removable prosthesis. Within the limitations of this study, predictable long-term implant rehabilitation outcomes were demonstrated for the edentulous maxilla using an immediate loading protocol without bone augmentation.

  14. Platelet Rich Fibrin (P.R.F.) in Reconstructive Surgery of Atrophied Maxillary Bones: Clinical and Histological Evaluations

    Science.gov (United States)

    Tatullo, Marco; Marrelli, Massimo; Cassetta, Michele; Pacifici, Andrea; Stefanelli, Luigi Vito; Scacco, Salvatore; Dipalma, Gianna; Pacifici, Luciano; Inchingolo, Francesco

    2012-01-01

    Introduction. Maxillary bone losses often require additional regenerative procedures: as a supplement to the procedures of tissue regeneration, a platelet concentrate called PRF (Platelet Rich Fibrin) was tested for the first time in France by Dr. Choukroun. Aim of the present study is to investigate, clinically and histologically, the potential use of PRF, associated with deproteinized bovine bone (Bio-Oss), as grafting materials in pre-implantology sinus grafting of severe maxillary atrophy, in comparison with a control group, in which only deproteinized bovine bone (Bio-Oss) was used as reconstructive material. Materials and Methods. 60 patients were recruited using the cluster-sampling method; inclusion criteria were maxillary atrophy with residual ridge piezosurgery in order to reduce trauma and to optimize the design of the operculum on the cortical bone. The reopening of the surgical area was scheduled at 3 different times. Results. 72 sinus lifts were performed with subsequent implants insertions. We want to underline how the histological results proved that the samples collected after 106 days (Early protocol) with the adding of PRF were constituted by lamellar bone tissue with an interposed stroma that appeared relaxed and richly vascularized. Conclusions. The use of PRF and piezosurgery reduced the healing time, compared to the 150 days described in literature, favoring optimal bone regeneration. At 106 days, it is already possible to achieve good primary stability of endosseous implants, though lacking of functional loading. PMID:23155361

  15. Clinical Evaluation of Small Diameter Straumann Implants in Partially Edentulous Patients: A 5-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    S. OZER

    2011-06-01

    Full Text Available Objective: The aim of the present study was to retrospectively evaluate small-diameter (3.3 mm Straumann® dental implants placed in the maxilla or the mandible over a period of 5 years in function.Materials and Methods: Twenty- eight partially edentulous patients received a total of 48 implants over a 5-year period. After the standard healing period (3 to 6 months, the implants were restored with single-tooth prostheses or fixed partial dentures. All patients were followed according to a strict maintenance program with regular recalls. The cumulative survival rates of implants were analyzed and prosthetic complications were assessed.Results: After 5 years of function, one single 10-mm-long implant in the maxillary premolar region was lost because of recurrent peri-implant infection in a female patient. Two single 10-mm-long maxillary implants placed in the posterior region were lost due to body fracture. The cumulative 5-year survival rate of the implants was 93.75 %. The most common prosthetic complication was loosening of the occlusal screw.Conclusion: Within the limited observation period and the number of patients included in this study, it may be concluded that the use of small-diameter implants appears to be predictable if clinical guidelines are followed and appropriate prosthetic restorations are provided. However, it should be noted that fatigue fracture may occur.

  16. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Geun Young Lee

    2017-09-01

    Full Text Available AIM: To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG. METHODS: In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. RESULTS: The number of antiglaucoma medications and the IOP reduction were similar between the 2 groups during the follow-up period. Although the mean IOP was similar, the IOP-fluctuation rate during the early postoperative period was significantly lower in the ExPress group than in the trabeculectomy group (P=0.038. A Kaplan-Meier survival curve analysis showed no significant success-rate difference between the groups (P=0.810. The corneal endothelial cell loss rate, moreover, was significantly lower in the ExPress group (P=0.05. CONCLUSION: ExPress implantation compared with trabeculectomy showed similar IOP-reduction and success rates along with lower IOP fluctuation and endothelial cell loss rates. For this reason, it can be considered to be the treatment of choice for patients with advanced glaucoma or low corneal endothelial cell density.

  17. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma.

    Science.gov (United States)

    Lee, Geun Young; Lee, Chong Eun; Lee, Kyoo Won; Seo, Sam

    2017-01-01

    To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG). In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP) values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. The number of antiglaucoma medications and the IOP reduction were similar between the 2 groups during the follow-up period. Although the mean IOP was similar, the IOP-fluctuation rate during the early postoperative period was significantly lower in the ExPress group than in the trabeculectomy group ( P =0.038). A Kaplan-Meier survival curve analysis showed no significant success-rate difference between the groups ( P =0.810). The corneal endothelial cell loss rate, moreover, was significantly lower in the ExPress group ( P =0.05). ExPress implantation compared with trabeculectomy showed similar IOP-reduction and success rates along with lower IOP fluctuation and endothelial cell loss rates. For this reason, it can be considered to be the treatment of choice for patients with advanced glaucoma or low corneal endothelial cell density.

  18. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma

    Science.gov (United States)

    Lee, Geun Young; Lee, Chong Eun; Lee, Kyoo Won; Seo, Sam

    2017-01-01

    AIM To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG). METHODS In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP) values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. RESULTS The number of antiglaucoma medications and the IOP reduction were similar between the 2 groups during the follow-up period. Although the mean IOP was similar, the IOP-fluctuation rate during the early postoperative period was significantly lower in the ExPress group than in the trabeculectomy group (P=0.038). A Kaplan-Meier survival curve analysis showed no significant success-rate difference between the groups (P=0.810). The corneal endothelial cell loss rate, moreover, was significantly lower in the ExPress group (P=0.05). CONCLUSION ExPress implantation compared with trabeculectomy showed similar IOP-reduction and success rates along with lower IOP fluctuation and endothelial cell loss rates. For this reason, it can be considered to be the treatment of choice for patients with advanced glaucoma or low corneal endothelial cell density. PMID:28944196

  19. Use of reconstructed CT images for evaluation of the position of screw-type temporary anchorage devices implanted in the maxillary molar region

    International Nuclear Information System (INIS)

    Hashimoto, Kazuya

    2007-01-01

    Temporary anchorage devices (TAD) have recently been employed for orthodontic treatment. I attempted to find the safest position for placing the screw-type TAD in the maxillary molar region. Using reconstructed CT images, I investigated the buccolingual and mesiodistal lengths of the interalveolar septums between the maxillary first premolar, second premolar, first molar, and the second molar. For the first and second molars, I measured the distance from the alveolar crest to the maxillary sinus. The results indicated that the safest position for placing a screw-type TAD was the interalveolar septum between the maxillary first molar and the second premolar at about a depth of 4-6 mm from the alveolar crest on the buccal side, and at about a depth of 2-6 mm from the alveolar crest on the palatal side. (author)

  20. [Maxillary advancement osteotomy with sequelae cleft lip and palate: Dilemma between occlusion and aesthetic profile].

    Science.gov (United States)

    Vigneron, A; Morand, B; Lafontaine, V; Lesne, V; Lesne, C; Bettega, G

    2015-11-01

    Maxillary hypoplasia is a common sequela of cleft lip and palate. Its surgical treatment consists in a maxillary advancement by distraction or by conventional orthognathic surgery but morphological results are unpredictable. Our goal in this study was to see if the esthetical results (on the lip and the nose) of maxillary advancement were correlated to the preservation of lateral incisor space of the cleft side. This retrospective study included 38 patients operated between 2002 and 2013. Unilateral clefts were studied independently from bilateral clefts. Profile aesthetics was evaluated independently and subjectively by two surgeons and scored on an 8-point scale. The result was classified as "good" if the score was superior or equal to 6. The score was correlated to the following parameters: amount of maxillary advancement, upper incisor axis, preservation of the missing lateral incisor space. In the "good result" group, the space of the lateral incisor was less often preserved. The nasolabial angle was more open and the upper central incisor axis more vertical. These results were more pronounced in bilateral clefts, but also found in unilateral clefts. Under reservation of the subjective evaluation and of the small number of patients, it seemed that lateral incisor space closure improved the profile of patients treated by maxillary advancement for cleft lip and palate sequelae. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Zygoma Implant-Supported Prosthetic Rehabilitation of a Patient After Bilateral Maxillectomy.

    Science.gov (United States)

    Celakil, Tamer; Ayvalioglu, Demet Cagil; Sancakli, Erkan; Atalay, Belir; Doganay, Ozge; Kayhan, Kivanc Bektas

    2015-10-01

    Maxillectomy defects may vary from localized to extensive soft and hard tissue loss. In addition to physical and psychologic damages, functional and aesthetic aspects must be restored. This clinical report describes the rehabilitation of a patient with a zygoma implant-supported obturator prosthesis caused by a subtotal bilateral maxillectomy due to a squamous oral cell carcinoma. Prosthetic rehabilitation of this patient was performed after zygoma implant surgery. A maxillary obturator prosthesis supported by 2 osseointegrated zygoma implants was fabricated. Despite limited mouth opening and anatomic deficiencies, the patient's aesthetic and functional demands were fulfilled.

  2. Zygomatic implant-retained fixed complete denture for an elderly patient.

    Science.gov (United States)

    Baig, Mirza Rustum; Rajan, Gunaseelan; Yunus, Norsiah

    2012-06-01

    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  3. Implant rehabilitation in bruxism patient

    Science.gov (United States)

    Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas

    2014-01-01

    A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215

  4. Ankyloglossia as a risk factor for maxillary hypoplasia and soft palate elongation: A functional - morphological study.

    Science.gov (United States)

    Yoon, A J; Zaghi, S; Ha, S; Law, C S; Guilleminault, C; Liu, S Y

    2017-11-01

    To characterize associations between restricted tongue mobility and maxillofacial development. Cross-sectional cohort study of 302 consecutive subjects from an orthodontic practice. Tongue mobility (measured with tongue range of motion ratio [TRMR] and Kotlow free tongue measurement) was correlated with measurements of the maxillofacial skeleton obtained from dental casts and cephalometric radiographs. Tongue range of motion ratio and Kotlow measures of restricted tongue mobility were associated with (i) ratio of maxillary intercanine width to canine arch length, (ii) ratio of maxillary intermolar width to canine arch length and (iii) soft palate length. Restricted tongue mobility was not associated with hyoid bone position or Angle's skeletal classification. Restricted tongue mobility was associated with narrowing of the maxillary arch and elongation of the soft palate in this study. These findings suggest that variations in tongue mobility may affect maxillofacial development. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. The effect of cleft maxillary distraction osteogenesis on the levator veli palatini and velopharyngeal function.

    Science.gov (United States)

    Chen, Philip Kuo-Ting; Por, Yong-Chen; Liou, Eric Jein-Wein; Chang, Frank Chun-Shin

    2015-05-01

    Le Fort I maxillary distraction with the rigid external distraction (RED) device is performed to correct severe midface retrusion in cleft patients, but it may adversely affect velopharyngeal function. This study aims to investigate the angular changes in the levator veli palatini (LVP) and its influence on velopharyngeal function after maxillary distraction using 3-dimensional computed tomography (3D CT) scan volume rendered images. This was a retrospective study of 12 patients. Group 1 had no velopharyngeal function deterioration and group 2 had velopharyngeal function deterioration. Preoperative and 1 year postoperative CT scans were analyzed with Mimics v10 software. Segmentation of the LVP and the nasopharyngeal airway was performed and volumetric images were obtained. Six measurements were made: (1) the angle between the levator plane and the Frankfort horizontal, (2) the angle between the levator plane and the soft palate plane, (3) the angle between the 2 LVP muscles, (4) the pharyngeal depth, and (5, 6) the movement of the inferior pharyngeal point with respect to the horizontal and vertical planes. The independent samples t test, Mann-Whitney test, and paired t tests were used for statistical analyses (P < 0.05). Group 2 had statistically significant reduction in the angle between the levator plane and Frankfort horizontal as well as the soft palate plane. Group 1 had a statistically significant increase in the pharyngeal depth and movement of the inferior pharyngeal point with respect to the horizontal plane. A decrease in the angle between the levator plane and the Frankfort horizontal or the soft palate plane was associated with velopharyngeal function deterioration.

  6. New methods for oral rehabilitation with the dental implant

    International Nuclear Information System (INIS)

    Chang Joon Yim; Marx, R.E.

    1999-01-01

    Now autogenous bone and allogeneic bone implants offer a wide variety of surgical options to surgeons in the advanced dental implant surgery, whether its used separately or in combination. The surgeons are able to make judicious and fruitful choices, only with a thorough knowledge of the basic biological principles and skillful techniques. Further development of the new materials or new techniques in bone grafts has enabled the clinicians to repair even the most difficult bony defects successfully during dental implant surgery. Currently, researchers' and clinicians' interests were focused on the various growth factors such as PDGF, TGF-beta or BMPs. Platelets has been known as a source of PDGF and TGF-beta. Current technique of autogenous cancellous cellular bone graft mixed with the patient's own concentrated platelet rich plasma(PRP) gel has been developed. Several recombinant human BMP(rh-BMP)s has been studied for human clinical trial in a variety of bone defect cases related to the dental implants and FDA approval. Some showed favorable results. Rh-BMP7 was clinically tried to fill the space defects after lifting the Schneiderian membrane in the maxillary sinus of the patient. In several months dental implants were successfully placed at the edentulous maxillae where the maxillary sinus defects has been filled with rh-BMP will be discussed. The authors will introduce the basic ideas, basic histological study and the current techniques of bone grafts mixed with autogenous platelet concentrates gel and its clinical cases applied for the dental implant surgery. The idea of 'tent pole' technique was applied for the severely atrophic mandible and the results were predictable

  7. The not-so-harmless maxillary primary first molar extraction.

    Science.gov (United States)

    Northway, W M

    2000-12-01

    Premature loss of primary molars has been associated with space loss and eruptive difficulties, especially when the loss occurs to the primary second molars and when it occurs early. This has not been thought to be the case for primary first molars. The author revisited 13 cases from an earlier study on the effects of premature loss of maxillary primary molars. These longitudinal cases were scrutinized, using serial panoramic radiographs, to explain the irregular response in terms of dental migration. The author presents two case reports. In the earlier study, the author used digitized study casts and the concept of D + E space--the space occupied by the primary first and second molars--to describe the dental migration that occurred after premature tooth loss. Using analysis of variance on data generated using an instrument capable of measuring in tenths of millimeters, the author produced findings regarding the amount of space loss, rate of space loss, effect of age at loss, amount of space regained at the time of replacement by the permanent tooth and effect on Angle's classification. Finally, the author created a simulation describing directional change; this revealed that the maxillary primary first molar loss resulted in a mesial displacement of the permanent canine during eruption. When the maxillary primary first molar is lost prematurely, the first premolar erupts in a more mesial direction than normal, as a result of the mesial incline of the primary second molar, and consumes the space of the permanent canine, which becomes blocked out. Rather than use a space maintainer after the premature loss of the maxillary primary first molar, the author suggests, clinicians can choose from a number of other options for preventing the first premolar from erupting too far in a mesial direction.

  8. Maxillary Sinus Floor Augmentation

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Jensen, Janek Dalsgaard

    2017-01-01

    , radiological and histomorphometric outcome as well as complications are presented after maxillary sinus floor augmentation applying the lateral window technique with a graft material, maxillary sinus membrane elevation without a graft material and osteotome-mediated sinus floor elevation with or without...

  9. The effects of micro-implant assisted rapid palatal expansion (MARPE) on the nasomaxillary complex--a finite element method (FEM) analysis.

    Science.gov (United States)

    MacGinnis, Matt; Chu, Howard; Youssef, George; Wu, Kimberley W; Machado, Andre Wilson; Moon, Won

    2014-08-29

    Orthodontic palatal expansion appliances have been widely used with satisfactory and, most often, predictable clinical results. Recently, clinicians have successfully utilized micro-implants with palatal expander designs to work as anchors to the palate to achieve more efficient skeletal expansion and to decrease undesired dental effects. The purpose of the study was to use finite element method (FEM) to determine the stress distribution and displacement within the craniofacial complex when simulated conventional and micro-implant-assisted rapid palatal expansion (MARPE) expansion forces are applied to the maxilla. The simulated stress distribution produced within the palate and maxillary buttresses in addition to the displacement and rotation of the maxilla could then be analyzed to determine if micro-implants aid in skeletal expansion. A three-dimensional (3D) mesh model of the cranium with associated maxillary sutures was developed using computed tomography (CT) images and Mimics modeling software. To compare transverse expansion stresses in rapid palatal expansion (RPE) and MARPE, expansion forces were distributed to differing points on the maxilla and evaluated with ANSYS simulation software. The stresses distributed from forces applied to the maxillary teeth are distributed mainly along the trajectories of the three maxillary buttresses. In comparison, the MARPE showed tension and compression directed to the palate, while showing less rotation, and tipping of the maxillary complex. In addition, the conventional hyrax displayed a rotation of the maxilla around the teeth as opposed to the midpalatal suture of the MARPE. This data suggests that the MARPE causes the maxilla to bend laterally, while preventing unwanted rotation of the complex. In conclusion, the MARPE may be beneficial for hyperdivergent patients, or those that have already experienced closure of the midpalatal suture, who require palatal expansion and would worsen from buccal tipping of the teeth

  10. Computational tool for postoperative evaluation of cochlear implant patients; Ferramenta computacional para avaliacao pos-operatoria de pacientes com implante coclear

    Energy Technology Data Exchange (ETDEWEB)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de [Universidade Estadual Paulista Julio de Mesquita Filho (IBB/UNESP), Botucatu, SP (Brazil). Instituto de Biociencias; Altemani, Joao M.C.; Castilho, Arthur M. [Universidade Estadual de Campinas (HC/UNICAMP), Campinas, SP (Brazil). Hospital de Clinicas

    2016-07-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  11. A mandibular implant-supported fixed complete dental prosthesis in a patient with Sjogren syndrome: case report.

    Science.gov (United States)

    Spinato, Sergio; Soardi, Carlo Maria; Zane, Anna Maria

    2010-06-01

    The article describes the treatment and 1 year follow-up of a patient with Sjogren syndrome, treated with 6 intraforaminal mandibular implants with delayed loading and an implant-retained fixed prosthesis. The maxillary arch has been treated with a complete denture. This made an enormous difference in comfort and function for the patient. Radiographic check-ups did not reveal any peri-implant bone loss after 1 year of loading.

  12. The Shape of the Maxillary Central Incisors and Its Correlation with Maxillary Anterior Papillary Display: A Clinical Study.

    Science.gov (United States)

    Nichani, Ashish S; Ahmed, Arshia Zainab; Ranganath, V

    2016-01-01

    The aim of this study was to define shapes of maxillary central incisors and determine their relationship with the visual display of interdental papillae during smiling. A sample of 100 patients aged 20 to 25 years were recruited. Photographs were taken and gingival angle, crown width (CW), crown length (CL), contact surface (CS), CW/CL ratio, CS/CL ratio, gingival smile line (GSL), and interdental smile line (ISL) were measured. The data showed an increase in GA leading to an increase in CW and CS/CL ratio. Women showed a higher percentage of papillary display compared with men. This study reinforces the proposed hypothesis that the shape of the teeth and papilla affect the periodontium.

  13. Minimal guided bone regeneration procedure for immediate implant placement in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Nettemu Sunil Kumar

    2013-01-01

    Full Text Available The anterior maxilla presents a challenging milieu interior for ideal placement of implants because of the compromised bone quality. With the advent of intraoral bone harvesting and augmentation techniques, immediate implant placement into fresh extraction sockets have become more predictable. Immediate implant placement has numerous advantages compared to the delayed procedure including superior esthetic and functional outcomes, maintenance of soft and hard tissue integrity and increased patient compliance. This case report exhibits immediate implant placement in the maxillary esthetic zone by combining a minimal invasive autogenous block bone graft harvest technique for ensuring successful osseointegration of the implant at the extraction site.

  14. Five-year follow-up of maxillary distraction osteogenesis on the dentofacial structures of children with cleft lip and palate.

    Science.gov (United States)

    Gürsoy, Seda; Hukki, Jyri; Hurmerinta, Kirsti

    2010-04-01

    To determine the long-term outcomes of maxillary distraction osteogenesis (DO) on skeletal and dental structures of growing children with cleft lip and palate. Severe maxillary deficiencies were treated with a rigid external distractor device followed by a consolidation period. Preoperative and postoperative orthodontic treatment lasted a mean of 14 months and 16 months, respectively. The landmarks on standard lateral cephalometric x-rays were digitized and angular and linear measurements were compared by Student's t test to assess the changes before distraction, after distraction, after consolidation, at 1-year follow-up, and at 2-year follow-up. Long-term follow-up (5 years) was interpreted according to mean values because of the small sample size. During DO, the maxilla was horizontally advanced and moved downward as indicated by the significant changes at the SNA and ANB angles (13 degrees) and at maxillary points A, ANS, and PNS. The increase at the divergence between the maxilla and mandible (ANS-PNS/Me-Go) was found to be significant. The mandible (B, Pg, Me) also moved downward (2-4 mm) and backward (Gn) significantly because of mandibular autorotation. The overjet increased (mean increase, 13.7 mm) and the overbite decreased significantly. The advancement of the upper incisors (13.3 mm) and upper molars (12.3 mm) was slightly more than the skeletal points. In a long-term follow-up (5 years), the ANB angle and horizontal overjet continued to decrease but both values remained positive, indicating a Class I relationship. This cephalometric study of young adolescents with cleft lips and palates found great improvement in dentofacial structure after maxillary DO and stability in maxillary skeletal advancement. During a 5-year follow-up, the achieved dentoskeletal treatment outcome was partly diminished. The extreme need for maxillary advancement or facial correction because of psychosocial stress and providing an easier approach for finalizing osteotomy are the

  15. Upper full arch rehabilitation with sinus by-pass with tilted implants via tapered-threaded expanders in low density bone: a clinical trial.

    Science.gov (United States)

    Andreasi Bassi, M; Andrisani, C; Lico, S; Ormanier, Z; Arcuri, C

    2016-01-01

    In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants, in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors present a case series of full-arch rehabilitations performed with this procedure named: Tilted Implant Expansion Osteotomy (TIEO). 12 patients (5 males and 7 females, average age 58.5 ± 8.1 years) with totally or partially edentulous maxilla were enrolled in this study. For each patient 4 implants were placed, the anterior implants in the area of lateral incisors or canines while, the posterior implants, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 48 cylindrical two-piece implants were placed, 24 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 6 months, the second stage surgery was performed. The cases were finalized by means of a hybrid metal-acrylic prosthesis. The post finalization follow-up was at 12 months. Survival rate was 100% since none fixtures were lost. At the one-year follow up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. TIEO is a promising surgical procedure for full-arch rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques.

  16. PIXE depth profiling using variation of detection angle

    International Nuclear Information System (INIS)

    Miranda, J.; Rickards, J.; Trejo-Luna, R.

    2006-01-01

    A method to apply particle induced X-ray emission (PIXE) for depth profiling, based on the variation of the X-ray detection angle, is proposed. The procedure uses X-ray yields normalized to those emitted at a particular reference angle. Application of the method to implanted samples and thin metallic films gave excellent results regarding the range of implanted ions and film thickness, respectively. However, there is no complete information about the width of the distribution of the implanted ions, emphasizing the need to develop a full mathematical algorithm to obtain the general depth profile

  17. The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT.

    Science.gov (United States)

    González-García, Raúl; Monje, Florencio

    2013-08-01

    The aim of this study was to objectively assess the reliability of the cone-beam computed tomography (CBCT) as a tool to pre-operatively determine radiographic bone density (RBD) by the density values provided by the system, analyzing its relationship with histomorphometric bone density expressed as bone volumetric fraction (BV/TV) assessed by micro-CT of bone biopsies at the site of insertion of dental implants in the maxillary bones. Thirty-nine bone biopsies of the maxillary bones at the sites of 39 dental implants from 31 edentulous healthy patients were analyzed. The NobelGuide™ software was used for implant planning, which also allowed fabrication of individual stereolithographic surgical guides. The analysis of CBCT images allowed pre-operative determination of mean density values of implant recipient sites along the major axis of the planned implants (axial RBD). Stereolithographic surgical guides were used to guide implant insertion and also to extract cylindrical bone biopsies from the core of the exact implant site. Further analysis of several osseous micro-structural variables including BV/TV was performed by micro-CT of the extracted bone biopsies. Mean axial RBD was 478 ± 212 (range: 144-953). A statistically significant difference (P = 0.02) was observed among density values of the cortical bone of the upper maxilla and mandible. A high positive Pearson's correlation coefficient (r = 0.858, P micro-CT at the site of dental implants in the maxillary bones. Pre-operative estimation of density values by CBCT is a reliable tool to objectively determine bone density. © 2012 John Wiley & Sons A/S.

  18. Vector alignment in maxillary distraction osteogenesis.

    Science.gov (United States)

    Uckan, Sina; Arman, Ayca; Bayram, Burak; Celik, Erkan

    2006-09-01

    Maxillary distraction osteogenesis is an alternative treatment of cleft patients with severe maxillary hypoplasia. The aim of this paper is to present the combined surgical/orthodontic treatment of a cleft lip and palate patient and to evaluate the maxillary distraction procedure and the distraction vector in high Le Fort I osteotomy.

  19. Elders with implant overdentures: a 22-year clinical report.

    Science.gov (United States)

    Alsabeeha, Nabeel H M

    2012-09-01

    To report on the long-term survival and prosthodontic maintenance of two edentulous adults with mandibular overdentures supported by hydroxyapatite (HA)-coated implants. Mandibular implant overdentures are a successful treatment option with positive impact on the quality of life of elderly edentulous adults. Long-term survival of the implants requires continued rigorous prosthodontic maintenance. Two elderly edentulous adults with mandibular overdentures supported by 2 HA-coated implants were presented for prosthodontic rehabilitation after 22 years of placement. The implants were osseo-integrated and surviving at presentation based on accepted criteria. The mandibular implant overdentures suffered recurrent loss of retention and stability. Prosthodontic treatment involving the replacement of defective attachment systems and construction of new sets of mandibular implant overdentures opposing complete maxillary dentures is presented. The long-term survival of mandibular 2-implant overdentures requires continued prosthodontic maintenance. A conservative approach in the rehabilitation of two older edentulous adults with mandibular 2-implant overdentures was described including proper selection of attachment systems. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  20. Orthopantomographic study of the maxillary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Yu, Dong Su [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1971-11-15

    The author has observed the orthopantomograms of the maxillary sinus which were taken by special exposure method to study mesiodistal dimension, shape, symmetrical relationship, bony septum of the maxillary sinus and relationship between upper lst molar and the maxillary sinus, that were selected 56 cases of 23 to 27 years old male, who have good systemic conditions and no missing teeth on upper posterior molar in normal occlusion, and obtained following conclusions: 1. Mesiodistal dimensions of the maxillary sinus are shown as follows; The mean of left dimension is 50.94 {+-} 8.34 mm and of right dimension is 49.50 {+-} 9.87 mm. 2. To the shape of the maxillary sinus, V or U shape are 33 cases(29.5%) and W shape are 77 cases (70.5%). 3. In the ralationship between upper lst molar and floor of the maxllary sinus, superimposition are 62 cases (55.36%) a nd approach are 50 cases (44.64%). 4. In the right and left symmetrical relationship of the maxillary sinus, symmetry are 37 cases (66.07%) and asymmetry are 19 cases (33.93%). 5. The bony septums in the maxillary sinuses revealed that presence of bony septums are 29 cases (25.8%) and absence ar e 83 cases (74.11%).

  1. Effects of incident energy and angle on carbon cluster ions implantation on silicon substrate: a molecular dynamics study

    Science.gov (United States)

    Wei, Ye; Sang, Shengbo; Zhou, Bing; Deng, Xiao; Chai, Jing; Ji, Jianlong; Ge, Yang; Huo, Yuanliang; Zhang, Wendong

    2017-09-01

    Carbon cluster ion implantation is an important technique in fabricating functional devices at micro/nanoscale. In this work, a numerical model is constructed for implantation and implemented with a cutting-edge molecular dynamics method. A series of simulations with varying incident energies and incident angles is performed for incidence on silicon substrate and correlated effects are compared in detail. Meanwhile, the behavior of the cluster during implantation is also examined under elevated temperatures. By mapping the nanoscopic morphology with variable parameters, numerical formalism is proposed to explain the different impacts on phrase transition and surface pattern formation. Particularly, implantation efficiency (IE) is computed and further used to evaluate the performance of the overall process. The calculated results could be properly adopted as the theoretical basis for designing nano-structures and adjusting devices’ properties. Project supported by the National Natural Science Foundation of China (Nos. 51622507, 61471255, 61474079, 61403273, 51502193, 51205273), the Natural Science Foundation of Shanxi (Nos. 201601D021057, 201603D421035), the Youth Foundation Project of Shanxi Province (Nos. 2015021097), the Doctoral Fund of MOE of China (No. 20131402110013), the National High Technology Research and Development Program of China (No. 2015AA042601), and the Specialized Project in Public Welfare from The Ministry of Water Resources of China (Nos. 1261530110110).

  2. Is there a correlation between nasal septum deviation and maxillary transversal deficiency? A retrospective study on prepubertal subjects.

    Science.gov (United States)

    Ballanti, Fabiana; Baldini, Alberto; Ranieri, Salvatore; Nota, Alessandro; Cozza, Paola

    2016-04-01

    Deviated nasal septum may cause a reduction of the nasal airflow, thus, during the craniofacial development, a reduced nasal airflow could originate a chronic mouth-breathing pattern, related with moderate to severe maxillary constriction. The aim of this retrospective study is to analyze the correlation between maxillary transverse deficiency and nasal septum deviation. Frontal cephalograms were performed on 66 posterior-anterior radiographs of subjects (34M, 32F; mean age 9.95±2.50 years) with maxillary transverse deficiency and on a control group of 31 posterior-anterior radiographs of subjects (13M, 18F; 9.29±2.08 years). Angular parameters of the nasal cavities were recorded and compared between the two groups using a Student's t-test. Generally all the parameters are very similar between the two groups except for the ASY angle that differs for about the 27%; anyway the Student's t-test showed no statistically significant differences between the two groups (mostly p>0.20). This study failed to show an association between transverse maxillary deficiencies and nasal septum deviations. Moreover, no significant differences were found between the mean nasal cavities dimensions in subjects with transverse maxillary deficiency and the control group. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    Science.gov (United States)

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  4. Keratocystic odontogenic tumor with impacted maxillary third molar involving the right maxillary antrum:An unusual case report

    Directory of Open Access Journals (Sweden)

    Abhishek Gupta

    2011-01-01

    Full Text Available The odontogenic keratocyst (OKC, first described by Phillipsen in 1956, has metamorphosized as a keratocystic odontogenic tumor (KCOT as reported in WHO classification of head and neck tumors in 2005. KCOT is a benign intraosseous neoplasm of the jaw and its occurrence in maxilla is unusual and its appearance in maxillary antrum along with maxillary impacted third molar is very uncommon. This article reports a case of KCOT associated with impacted maxillary third molar in right maxillary antrum and describes its rare site of occurrence.

  5. Computational tool for postoperative evaluation of cochlear implant patients

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de; Altemani, Joao M.C.; Castilho, Arthur M.

    2016-01-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  6. Short-term changes in temporomandibular joint function in subjects with cleft lip and palate treated with maxillary distraction osteogenesis.

    Science.gov (United States)

    Hashimoto, K; Otsuka, R; Minato, A; Sato-Wakabayashi, M; Takada, J; Inoue-Arai, M S; Miyamoto, J J; Ono, T; Ohyama, K; Moriyama, K

    2008-05-01

    To investigate the short-term effects of maxillary distraction osteogenesis (DO) on temporomandibular joint (TMJ) function in 21 subjects with cleft lip and palate (CLP). Design - Morphological changes in the maxillofacial region were measured using lateral cephalometric radiographs taken immediately before (pre-DO) and after DO (post-DO) and 1 year after DO (1-year follow-up). A questionnaire was evaluated using a visual analog scale. A chi-square test was used to compare the prevalence of TMJ symptoms between pre-DO and 1-year follow-up. The Spearman correlation coefficient was used to determine the correlation between changes in cephalometric variables and TMJ symptoms in association with maxillary DO. Statistical significance was set at p < 0.05. Results - The ANB (anteroposterior relationship of the maxilla with the mandible) angle and the mandibular plane angle at pre-DO, post-DO, and 1-year follow-up were -4.3 degrees , +5.8 degrees , +4.3 degrees and 32.1 degrees , 33.5 degrees , 33.6 degrees , respectively. The average amounts of anterior and downward movement of the maxilla at post-DO and 1-year follow-up were 8.3, -1.3 and 0.9, 1.1 mm, respectively. The prevalence of TMJ symptoms showed no significant increase in association with maxillary DO. Moreover, there was no significant correlation between changes in cephalometric variables and TMJ symptoms. Conclusion - These results suggest that there was no short-term (i.e., up to 1 year after DO) effect of maxillary DO on TMJ function in subjects with CLP.

  7. Comparison of panoramic radiograph with cone-beam computed tomography in assessment of maxillary sinus floor and nasal floor

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Bokkasam

    2015-01-01

    Full Text Available Introduction: Panoramic radiograph is frequently prescribed by dentists for implant planning and, hence, accurate assessment of anatomical structures in panoramic radiograph is of utmost importance. Aims: The aim of the present study is to know the accuracy of panoramic radiograph in assessment of relationship between maxillary sinus floor and posterior teeth roots, and the distance from alveolar crest to nasal floor by comparing it with that of cone-beam computed tomographic (CBCT image. Materials and Methods: Panoramic and CBCT images of 30 patients were analyzed. The topographic relationship of each root of posterior teeth to the maxillary sinus floor was evaluated and classified into three classes. The distance from the peak point on maxillary alveolar crest to nasal floor was measured in panoramic radiograph as well as in CBCT image. All the measurements were made by built-in measurement tools. Results: Class 1 roots in panoramic radiograph showed high agreement (86% with CBCT image, followed by class 0 (76%. There was a significant difference in the measurements of alveolar bone height (ABH in the nasal floor region with a P value of 0.018. Conclusion: Panoramic radiograph is reliable in assessment of nasal floor and maxillary sinus, provided position of the patient, distortion, and the inherent magnification factor are taken into consideration.

  8. Aesthetics and Survival of Immediately Restored Implants in Partially Edentulous Anterior Maxillary Patients

    Directory of Open Access Journals (Sweden)

    Roni Kolerman

    2018-03-01

    Full Text Available This retrospective study was undertaken to determine survival rates and aesthetic outcomes of immediate placement of multiple implants at anterior maxilla sites. One hundred and eighteen implants placed in 39 patients (21 women and 18 men; average age 58.3 years were immediately restored (24–72 h after placement. Aesthetic assessment, radiographic bone loss, and biological and prosthetic complications were evaluated. Data collection between 12 and 84 months (mean 32.2 ± 18 after final prosthetic installation revealed that no implants were lost, and that 106/118 (89.8% implants had no more than 1.5 mm of bone loss by the end of the first year and an additional 0.2 mm for each successive year. The marginal bone loss was higher for extractions due to periodontitis compared to extractions due to caries (mean mesial loss of 1.37 mm vs. 1.01 mm, respectively, and mean distal loss of 1.37 mm and 0.99 mm, respectively, p = 0.001. The mesial papilla was present in 83/118 implants (70.3%, while the distal papilla was present in 76/118 implants (64.4%. The cervical metallic part of the abutment was exposed in 16/118 (13.5% implants. There was a higher ratio of recessions and missing papillae in patients in whom the extractions were performed due to periodontal reasons. Within the limitations of the present study, aesthetic and radiographic parameters support immediate restoration of partially edentulous maxillae.

  9. Allograft for maxillary sinus floor augmentation: a retrospective study of 90 cases.

    Science.gov (United States)

    Guerrero, Jaime S; Al-Jandan, Badr A

    2012-04-01

    The aim of this study is to demonstrate the clinical applicability and efficacy of an allograft for maxillary sinus augmentations in patients requiring placement of dental implants. Sixty consecutive patients underwent a total of 90 sinus augmentations. Twenty-nine were women and 31 men, with a mean age of 54 years. Twenty-six patients received a bilateral procedure and 34 unilateral. All cases were treated with the lateral wall technique. Allograft consisted of demineralized freeze-dried blocks in 6 cases, particulate in 82 cases, and a combination of both in 2 cases. In 30 patients, it was combined with platelet-rich plasma. A total of 84 implants were inserted. Bone samples of grafted areas were obtained in two patients for histological examination. Seventy-three implants were clinically successful at the reentry time. Eleven implants in seven patients were removed between 15 days and 6 months after their placement. Seven of these implants were replaced and received prostheses as well, for an overall postloading success rate of 95.2%. Follow-up for all patients after final restoration was between 12 and 96 months. Specimen's histological evaluation revealed bone formation and evidence of inflammatory infiltrate. Based on the findings of this study, it can be suggested that the use of the demineralized freeze-dried bone allograft from the Banco de Huesos y Tejidos Fundación Cosme y Damian for sinus augmentation is effective and constitutes a feasible therapeutic alternative for implant placement.

  10. A study on projection angles for an optimal image of PNS water's view on children

    International Nuclear Information System (INIS)

    Son, Sang Hyuk; Song, Young Geun; Kim, Sung Kyu; Hong, Sang Woo; Kim, Je Bong

    2007-01-01

    This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patient's skull. And then, we calculated the incidence angles (angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general (random) patient's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patient's ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle (angle B) between OML and IP(Image Plate). The angle between OML and IP is about 43 .deg. in 4-years-old children, which is higher than 37 .deg. as age increases the angle decreases, it goes to 37 .deg. around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage

  11. Indian Board of Orthodontics case report: Orthodontic management of a Class II malocclusion in a growing patient with bilateral maxillary molar distalization

    Directory of Open Access Journals (Sweden)

    Salil Sunil Nene

    2016-01-01

    Full Text Available C.S., a 12-year, 1-month-old male patient, presented with the chief complaint of highly placed canines and irregular teeth. On examination and analysis of relevant records, he was diagnosed as an Angle's Class II malocclusion on an underlying Class I skeletal base, severely crowded maxillary arch with high labially placed canines, mild crowding in mandibular arch, retroclined lower incisors, an impacted mesiodens with convex profile, and acute nasolabial angle. He was treated with a nonextraction treatment plan that involved bilateral maxillary molar distalization using Hilgers pendulum appliance followed by fixed mechanotherapy. The posttreatment results were highly satisfactory showing improvement in facial esthetics and occlusal traits as well as good long-term stability as was evident in the 2-year, 6-month retention photographs.

  12. Maxillary advancement using distraction osteogenesis with intraoral device.

    Science.gov (United States)

    Takigawa, Yoko; Uematsu, Setsuko; Takada, Kenji

    2010-11-01

    This article describes the surgical orthodontic treatment of maxillary hypoplasia in a patient with cleft lip and palate using maxillary distraction osteogenesis with internal maxillary distractors. Maxillary advancement was performed to correct the retrusive maxillary facial profile and Class III malocclusion. Rotational movement of the distraction segment was made to correct the upper dental midline. Although maxillary advancement was insufficient because of unexpected breakage of the intraoral distractor after completion of the distraction, skeletal traction with a face mask compensated for the shortage. Successful esthetic improvement and posttreatment occlusal stability were achieved with no discernible relapse after 2 years of retention.

  13. Maxillary Anterior Segmental Distraction Osteogenesis to Correct Maxillary Deficiencies in a Patient With Cleft Lip and Palate.

    Science.gov (United States)

    Kageyama-Iwata, Asuka; Haraguchi, Seiji; Iida, Seiji; Aikawa, Tomonao; Yamashiro, Takashi

    2017-07-01

    This report describes a case of successful orthodontic treatment using maxillary anterior segmental distraction osteogenesis with an internal maxillary distractor and bilateral sagittal split ramus osteotomy in a girl with cleft lip and palate. A 16-year-old girl with unilateral cleft lip and palate exhibited midface retrusion because of growth inhibition of the maxillary complex and mandibular excess. After the presurgical orthodontic treatment, 6.0-mm advancement of the maxillary anterior segment and 4.0-mm set back of the mandible were performed. After a retention period, the patient's midface convexity was greatly improved and the velopharyngeal competence was preserved without relapse.

  14. Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.

    Science.gov (United States)

    Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon

    2015-01-01

    This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.

  15. The effect of thread pattern upon implant osseointegration.

    Science.gov (United States)

    Abuhussein, Heba; Pagni, Giorgio; Rebaudi, Alberto; Wang, Hom-Lay

    2010-02-01

    Implant design features such as macro- and micro-design may influence overall implant success. Limited information is currently available. Therefore, it is the purpose of this paper to examine these factors such as thread pitch, thread geometry, helix angle, thread depth and width as well as implant crestal module may affect implant stability. A literature search was conducted using MEDLINE to identify studies, from simulated laboratory models, animal, to human, related to this topic using the keywords of implant thread, implant macrodesign, thread pitch, thread geometry, helix angle, thread depth, thread width and implant crestal module. The results showed how thread geometry affects the distribution of stress forces around the implant. A decreased thread pitch may positively influence implant stability. Excess helix angles in spite of a faster insertion may jeopardize the ability of implants to sustain axial load. Deeper threads seem to have an important effect on the stabilization in poorer bone quality situations. The addition of threads or microthreads up to the crestal module of an implant might provide a potential positive contribution on bone-to to-implant contact as well as on the preservation of marginal bone; nonetheless this remains to be determined. Appraising the current literature on this subject and combining existing data to verify the presence of any association between the selected characteristics may be critical in the achievement of overall implant success.

  16. A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar

    International Nuclear Information System (INIS)

    Yoon, Hae Rym; Park, Chang Seo

    1998-01-01

    In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA in male and female adults in their 20 s on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop, and postop, root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows ; 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the accrual maxilla specimen were 2.83 mm, 4.51 mm, and 4.15 mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography.3. In cross-sectional view, when

  17. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports.

    Science.gov (United States)

    Han, Ji-Deuk; Cho, Seong-Ho; Jang, Kuk-Won; Kim, Seong-Gwang; Kim, Jung-Han; Kim, Bok-Joo; Kim, Chul-Hun

    2017-08-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst.

  18. Channeling effect for low energy ion implantation in Si

    International Nuclear Information System (INIS)

    Cho, K.; Allen, W.R.; Finstad, T.G.; Chu, W.K.; Liu, J.; Wortman, J.J.

    1985-01-01

    Ion implantation is one of the most important processes in semiconductor device fabrication. Due to the crystalline nature of Si, channeling of implanted ions occurs during this process. Modern devices become smaller and shallower and therefore require ion implantation at lower energies. The effect of channeling on ion implantation becomes a significant problem for low energy ion implantation. The critical angle for axial and planar channeling increases with decreasing energy. This corresponds to an increased probability for channeling with lowering of ion energy. The industry approach to avoid the channeling problem is to employ a tilt angle of 7 0 between the ion implantation direction and the surface normal. We approach the problem by mapping major crystalline axes and planes near the [100] surface normal. Our analysis indicates that a 7 0 tilt is not an optimum selection in channeling reduction. Tilt angles in the range 5 0 to 6 0 combined with 7 0 +- 0.5 0 rotation from the (100) plane are better selections for the reduction of the channeling effect. The range of suitable angles is a function of the implantation energy. Implantations of boron along well specified crystallographic directions have been carried out by careful alignment and the resulting boron profiles measured by SIMS. (orig.)

  19. Implant Mandibular Overdentures Retained by Immediately Loaded Implants: A 1-Year Randomized Trial Comparing the Clinical and Radiographic Outcomes Between Mini Dental Implants and Standard-Sized Implants.

    Science.gov (United States)

    Zygogiannis, Kostas; Aartman, Irene Ha; Parsa, Azin; Tahmaseb, Ali; Wismeijer, Daniel

    The aim of this 1-year randomized trial was to evaluate and compare the clinical and radiographic performance of four immediately loaded mini dental implants (MDIs) and two immediately loaded standard-sized tissue-level (STL) implants, placed in the interforaminal region of the mandible and used to retain mandibular overdentures (IODs) in completely edentulous patients. A total of 50 completely edentulous patients wearing conventional maxillary dentures and complaining about insufficient retention of their mandibular dentures were divided into two groups; 25 patients received four MDIs and 25 patients received two STL implants. The marginal bone loss (MBL) at the mesial and distal sides of each implant was assessed by means of standardized intraoral radiographs after a period of 1 year. Implant success and survival rates were also calculated. Immediate loading was possible for all patients in the first group. In the second group, an immediate loading protocol could not be applied for 10 patients. These patients were treated with a delayed loading protocol. A mean MBL of 0.42 ± 0.56 mm for the MDIs and 0.54 ± 0.49 mm for the immediately loaded STL implants was recorded at the end of the evaluation period. There was no statistically significant difference between the MDIs and the immediately loaded STL implants. Two MDIs failed, resulting in a survival rate of 98%. The success rate was 91%. For the immediately loaded conventional implants, the survival rate was 100% and the success rate 96.7% after 1 year of function. However, in 10 patients, the immediate loading protocol could not be followed. Considering the limitations of this short-term clinical study, immediate loading of four unsplinted MDIs or two splinted STL implants to retain mandibular overdentures seems to be a feasible treatment option. The marginal bone level changes around the MDIs were well within the clinically acceptable range.

  20. A 5- to 8-year retrospective study comparing the clinical results of implant-supported telescopic crown versus bar overdentures in patients with edentulous maxillae.

    Science.gov (United States)

    Zou, Duohong; Wu, Yiqun; Huang, Wei; Zhang, Zhiyong; Zhang, Zhiyuan

    2013-01-01

    The objective of this study was to compare implant survival and success rates, peri-implant parameters, and prosthodontic maintenance efforts for implant-supported telescopic crown overdentures and bar overdentures to restore maxillary edentulism. This retrospective clinical study involved patients with maxillary edentulism who were fitted with implant-supported overdentures from January 2004 to June 2007. During a 5- to 8-year follow-up period, the implant survival and success rates, biologic and mechanical complications, prosthodontic maintenance, and patient satisfaction were retrospectively analyzed. The data were evaluated statistically and P overdentures. Twenty-one patients chose telescopic crown overdentures and 23 patients chose bar overdentures. A total of 41 patients and 201 implants were available for follow-up. The implant survival and success rates, average bone resorption, and subjective patient satisfaction scores showed no difference between the telescopic crown and the bar overdenture group at follow-up. However, there were higher values for Plaque and Calculus Indexes in the bar group compared with the telescopic crown group, and these values showed a statistically significant difference annually from the 3-year follow-up (P overdentures provided a healthy peri-implant structure for implants in both groups. Implant-supported telescopic crown or bar overdentures can provide a good treatment option for patients with edentulous maxillae.

  1. Changes in speech following maxillary distraction osteogenesis.

    Science.gov (United States)

    Guyette, T W; Polley, J W; Figueroa, A; Smith, B E

    2001-05-01

    The purpose of this study was to describe changes in articulation and velopharyngeal function following maxillary distraction osteogenesis. This is a descriptive, post hoc clinical report comparing the performance of patients before and after maxillary distraction. The independent variable was maxillary distraction while the dependent variables were resonance, articulation errors, and velopharyngeal function. The data were collected at a tertiary health care center in Chicago. The data from pre- and postoperative evaluations of 18 maxillary distraction patients were used. The outcome measures were severity of hypernasality and hyponasality, velopharyngeal orifice size as estimated using the pressure-flow technique, and number and type of articulation errors. At the long-term follow-up, 16.7% exhibited a significant increase in hypernasality. Seventy-five percent of patients with preoperative hyponasality experienced improved nasal resonance. Articulation improved in 67% of patients by the 1-year follow-up. In a predominately cleft palate population, the risk for velopharyngeal insufficiency following maxillary distraction is similar to the risk observed in Le Fort I maxillary advancement. Patients being considered for maxillary distraction surgery should receive pre- and postoperative speech evaluations and be counseled about risks for changes in their speech.

  2. Therapeutic interaction of systemically-administered mesenchymal stem cells with peri-implant mucosa.

    Directory of Open Access Journals (Sweden)

    Ryosuke Kondo

    Full Text Available OBJECTIVES: The objective of this study was to investigate the effect of systemically transplanted mesenchymal stem cells (MSCs on the peri-implant epithelial sealing around dental implants. MATERIALS AND METHODS: MSCs were isolated from bone marrow of donor rats and expanded in culture. After recipient rats received experimental titanium dental implants in the bone sockets after extraction of maxillary right first molars, donor rat MSCs were intravenously transplanted into the recipient rats. RESULTS: The injected MSCs were found in the oral mucosa surrounding the dental implants at 24 hours post-transplantation. MSC transplantation accelerated the formation of the peri-implant epithelium (PIE-mediated mucosa sealing around the implants at an early stage after implantation. Subsequently, enhanced deposition of laminin-332 was found along the PIE-implant interface at 4 weeks after the replacement. We also observed enhanced attachment and proliferation of oral mucous epithelial cells. CONCLUSION: Systemically transplanted MSCs might play a critical role in reinforcing the epithelial sealing around dental implants.

  3. Assessment of age based on the pulp cavity width of the maxillary central incisors

    Directory of Open Access Journals (Sweden)

    Uday Ginjupally

    2014-01-01

    Full Text Available Aims and Objectives: The aim of this study was to estimate the age of the patients belonging to the age group of 15 - 55 years, attending the Department of Oral Medicine and Radiology, St. Joseph Dental College and Hospital, Eluru, based on the radiographic evaluation of the pulp cavity width of the maxillary central incisors. Materials and Methods: The study group comprised of 120 subjects. Intraoral periapical radiographs of the maxillary central incisors were taken for all subjects, using the conventional paralleling angle technique and the pulp cavity width was measured at the cervical and middle third using a digital vernier caliper. The data obtained was subjected to correlation and regression analysis. Results: A negative linear relationship was obtained between the age and pulp cavity width (cervical third, r = -0.459 and middle third, r = -0.704. Cubic regression analysis was done and the regression formulae were obtained. A mean difference of 0.1 years was obtained between the estimated age and real age, indicating the reliability of the derived formula. Conclusion: It can be concluded that the width of the pulp cavity of maxillary central incisors are reliable for estimation of age.

  4. Telescopic crowns as attachments for implant supported restorations: a case series.

    Science.gov (United States)

    Hoffmann, Oliver; Beaumont, Christian; Tatakis, Dimitris N; Zafiropoulos, Gregory-George

    2006-01-01

    The use of dental implants to support mandibular or maxillary overdentures is a widely used treatment modality. Advantages are an increase in retention, an increase in chewing ability, and easy access for oral hygiene procedures. While telescopic and conical crowns have been used for decades to connect natural teeth to overdentures, not many cases have been reported in the literature of telescopic crowns placed on implants to support overdentures. This article describes 7 patients with overdentures supported by telescopic crowns who received 65 implants (ITI Straumann). The cases presented in this report have been in function for up to 4.5 years. During that time no adverse events were reported. The use of telescopic crowns as attachments for implant-supported overdentures may be a viable treatment option.

  5. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    Science.gov (United States)

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.

  6. Randomized clinical trial comparing control of maxillary anchorage with 2 retraction techniques.

    Science.gov (United States)

    Xu, Tian-Min; Zhang, Xiaoyun; Oh, Hee Soo; Boyd, Robert L; Korn, Edward L; Baumrind, Sheldon

    2010-11-01

    The objective of this pilot randomized clinical trial was to investigate the relative effectiveness of anchorage conservation of en-masse and 2-step retraction techniques during maximum anchorage treatment in patients with Angle Class I and Class II malocclusions. Sixty-four growing subjects (25 boys, 39 girls; 10.2-15.9 years old) who required maximum anchorage were randomized to 2 treatment techniques: en-masse retraction (n = 32) and 2-step retraction (n = 32); the groups were stratified by sex and starting age. Each patient was treated by a full-time clinic instructor experienced in the use of both retraction techniques at the orthodontic clinic of Peking University School of Stomatology in China. All patients used headgear, and most had transpalatal appliances. Lateral cephalograms taken before treatment and at the end of treatment were used to evaluate treatment-associated changes. Differences in maxillary molar mesial displacement and maxillary incisor retraction were measured with the before and after treatment tracings superimposed on the anatomic best fit of the palatal structures. Differences in mesial displacement of the maxillary first molar were compared between the 2 treatment techniques, between sexes, and between different starting-age groups. Average mesial displacement of the maxillary first molar was slightly less in the en-masse group than in the 2-step group (mean, -0.36 mm; 95% CI, -1.42 to 0.71 mm). The average mesial displacement of the maxillary first molar for both treatment groups pooled (n = 63, because 1 patient was lost to follow-up) was 4.3 ± 2.1 mm (mean ± standard deviation). Boys had significantly more mesial displacement than girls (mean difference, 1.3 mm; P <0.03). Younger adolescents had significantly more mesial displacement than older adolescents (mean difference, 1.3 mm; P <0.02). Average mesial displacement of the maxillary first molar with 2-step retraction was slightly greater than that for en-masse retraction, but the

  7. Improved Beam Angle Control with SPV Metrology

    International Nuclear Information System (INIS)

    Steeples, K.; Tsidilkovski, E.; Bertuch, A.; Ishida, E.; Agarwal, A.

    2008-01-01

    A method of real-time monitoring of implant angle for state-of-the-art ion implant doping in integrated circuit manufacturing has been developed using Surface Photo Voltage measurements on conventional monitor wafers. Measurement results are analyzed and compared to other techniques.

  8. Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy

    Directory of Open Access Journals (Sweden)

    Indumathi Sivakumar

    2014-01-01

    Full Text Available The purpose of this case report is to demonstrate the use of orthodontic miniscrew implant in the intrusion of overerupted molar as a preprosthodontic therapy. A 37-year-old woman with an overerupted maxillary right first molar encroaching on the opposing mandibular edentulous space was successfully intruded using a single miniscrew implant and partial fixed orthodontic appliance. The prosthodontic clinician may adopt this conservative and cost-effective strategy in their routine practice and avoid clinical crown reduction.

  9. Blood-flow change and recovery of sensibility in the maxillary dental pulp during and after maxillary distraction: a pilot study.

    Science.gov (United States)

    Harada, Kiyoshi; Sato, Masaru; Omura, Ken

    2004-11-01

    To examine the change in blood flow and recovery of sensibility in the maxillary dental pulp during and after maxillary distraction. The subjects included 5 patients undergoing high Le Fort I osteotomy and maxillary distraction (D-group) and a reference group of 14 patients who underwent a common single-segment Le Fort I osteotomy, 1-stage maxillary advancement, and mandibular setback surgery (C-group). Eleven (D-group) and 54 (C-group) maxillary incisors were assessed preoperatively and at 1-7 days, 14 days, and 3 months postoperatively. Pulpal blood flow (PBF) was measured by laser Doppler flowmetry, and pulpal sensibility (PS) was investigated by electrodiagnostics. From postoperative days 1 to 5 (the latency period), the PBF tended to be higher in the D-group than in the C-group. From day 6 to 3 months postoperatively (during and after maxillary distraction), the PBF values of the 2 groups were similar. The PS remained negative up to 14 days postoperatively in both groups. However, at 3 months after the operation, a higher proportion (90.9%) of teeth in the D-group was positive for PS. These results suggest that maxillary distraction is a favorable technique for maintenance of PBF and recovery of PS in the maxillary teeth after surgery.

  10. CT-MPR invaluable in diagnosing odontogenic maxillary sinusitis

    International Nuclear Information System (INIS)

    Aoki, Hideaki; Shimazu, Kaoru; Kamada, Morito; Shiroyama, Akihiro; Mouri, Daisuke; Yamashita, Masashi; Kawasaki, Yasunori; Koseki, Takakazu; Mouri, Manabu

    2001-01-01

    In everyday examination, it is usual to encounter odontogenic maxillary sinusitis patients. Odontogenic maxillary sinusitis is generally best diagnosed by dental X-ray imaging. Many medical facilities not having a dental X-ray unit use coronal computed tomography (CT) images to diagnose odontogenic maxillary sinusitis. Coronal CT imaging causes artifacts, however due to dental prosthesises. Computed tomography-Multiplanar reformation (CT-MPR) imaging has proved useful in evaluating the paranasal sinus because it is not influenced by dental prosthesises. We evaluated the usefulness of CT-MPR for diagnosing odontogenic maxillary sinusitis by retrospectively analyzing 16 patients, with the following results. We couldn't diagnose all cases of odontogenic maxillary sinusitis in posteroanterior and Waters projection images. Panoramic radiography is needed to diagnose odontogenic maxillary sinusitis. Dental X-ray imaging missed some cases, but all cases were diagnosed by CT-MPR imaging, giving a 100% diagnosestic rate. CT-MPR imaging is thus at least as valuable or better than dental X-ray imaging in diagnosing odontogenic maxillary sinusitis. (author)

  11. [Radiologic picture of maxillary sinus aspergilloma].

    Science.gov (United States)

    Kaczmarek, I; Bilska, J; Osmola, K; Nowaczyk, M T

    2010-06-01

    Mycotic infection of paranasal sinus could be the etiological factor of chronic sinusitis. The increase in number of fungal sinusitis cases have been reported recently among nonimmunocompromised patient after endodontic treatment of maxillary teeth. Nonspecific clinical signs and incorrect radiologic pictures interpretation as well as loss of therapeutic standards seems to be the cause of false negative diagnosis and difficulties in treatment of fungal sinusitis. Clinical and radiological picture of maxillary sinus aspergillosis was described in this paper. In the period of 2006-2009 in the Department of Maxillo-Facial Surgery 19 patient with fungal maxillary sinusitis was treated. The endodontic treatment of maxillary teeth of the related side was performed previously in 80% examined cases. In 2 cases there were immunocompromised patients with immunosuppressive treatment. In 16 cases patients were referred to our Department due to metallic foreign body of the maxillary sinus. Routine diagnostic radiological imaging was performed in each case: paranasal sinus view--Water's view and panoramic radiograph (orthopantomograph). In 4 cases imaging was extended with computer tomography (CT) visualization. The surgical treatment was performed in each case. The final diagnosis was puted on histopathological examination and fungal culture. In 16 cases of analysed group histopathological examination and fungal culture revealed aspergilosis. In 2 cases fungal culture was negative, but histopathology slices confirm presence of hyphae of Aspergillus. In 1 case the root canal sealer was found in the maxillary sinus. In none case invasive form of aspergillosis was confirmed. In all cases Water's view of paranasal sinuses and ortopantomograph showed partially or totally clouded sinus with well-defined, single or multifocal radiopaque object similar to metallic foreign body. Characteristic finding in CT imaging was well-defined radiodence concretions that have been attributed to

  12. Occlusal plane change after intrusion of maxillary posterior teeth by microimplants to avoid maxillary surgery with skeletal Class III orthognathic surgery.

    Science.gov (United States)

    Park, Hyo-Sang; Kim, Ji-Yeun; Kwon, Tae-Geon

    2010-11-01

    To increase stability and mandibular setback movement, surgical maxillary impaction is normally performed with mandibular setback surgery in treating adult skeletal Class III patients. This article demonstrates the use of microimplants for anchorage to intrude molars and the resultant rotation of the maxillary occlusal plane clockwise to increase the surgical mandibular setback and reduce the posterior vertical dimension instead of maxillary surgical impaction. A 21-year-old man with mandibular prognathism was treated with mandibular setback surgery that included orthodontic treatment for decompensation. Microimplants placed into the palatal alveolar bone between the maxillary first and second molars were used to intrude the maxillary posterior teeth and change the occlusal plane clockwise. This produced 4 mm more of distal movement of the chin during mandibular setback surgery compared with the surgical prediction with no change in the occlusal plane. These results were similar to those of 2-jaw surgery with maxillary posterior impaction. The intrusion of the maxillary posterior teeth with microimplants might prevent the need for maxillary surgery in adult skeletal Class III patients. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  13. Prevalence rate and dentoskeletal features associated with buccally displaced maxillary canines.

    Science.gov (United States)

    Mucedero, Manuela; Ricchiuti, Maria Rosaria; Cozza, Paola; Baccetti, Tiziano

    2013-06-01

    The aim of the study was to analyse the prevalence and distribution of buccally displaced canines (BDCs) in subjects scheduled for orthodontic treatment and to investigate the association between BDC and sagittal, vertical, and transverse dentoskeletal relationships. A study sample of 1852 subjects was examined, and it was divided randomly into two groups. A first group of 252 subjects served as control group: the 'reference' prevalence rates for the examined parameters were calculated in this group. The remaining 1600 subjects comprised the sample from which the experimental BDC group was derived. Presence of unilateral or bilateral maxillary BDC, ANB, and SN GOGn angles for sagittal and vertical skeletal relationships, intercanine and intermolar distances, and tooth crowding at the maxillary arch were recorded for each subject. The statistical significance of differences between the BDC and the control groups in transverse relations and tooth crowding at the upper arch was tested by means of independent sample t-tests. Chi-square tests were performed to compare the prevalence rates of BDC and also sagittal and vertical skeletal features in the two groups. The prevalence rate of BDC was 3.06 per cent with a male-to-female ratio of 1:1. BDC subjects exhibited a significant association with hyperdivergent skeletal relationships (38.8%), reduced maxillary intercanine width, and crowding in the upper arch. The presence of specific dentoskeletal characteristics can be considered as a risk indicator for developing a buccal displacement of upper permanent canines.

  14. Radiodiagnostics of maxillary osteomyelitis

    International Nuclear Information System (INIS)

    Klemova, J.; Jenca, A.; Hanusinova, V.; Danko, J.; Ondrasovicova, J.

    2006-01-01

    Osteomyelitis is defined as an inflammation or infection in bone tissues - cancellous bone, bone marrow, bone compacta and periosteum due to invasion of infection from surrounding tissues. Maxillary osteomyelitis is less common disease than osteomyelitis of mandible. This can be explained by anatomical structure of maxilla which is mainly composed of sinuses and thin bone lamellae. Such a structure allows rapid propagation of the infection to the surface. There have been examined and treated 70 patients with osteomyelitis of facial bones within past 15 years at Department of stomatology and maxillo-facial surgery of P.J. Safarik University in Kosice. Only four cases were diagnosed as maxillary osteomyelitis. The aim of this study was to mention the differences in anatomy and symptoms of acute and chronic stage of maxillary osteomyelitis and to give a detailed radiographic picture of this affliction. (authors)

  15. Postoperative Maxillary Cyst: A Case Report

    Directory of Open Access Journals (Sweden)

    Asiye Şafak Bulut

    2010-01-01

    Full Text Available Postoperative maxillary cyst is a quite rare delayed complication of surgical intervention associated with maxillary sinuses. It occurs many years after surgery. This paper describes a 54-year-old woman presenting with swelling of left cheek for seven-years duration. The orthopantomograph revealed a unilocular cystic radiolucency with well-defined margins in left maxillary sinus. In the computerized tomography, the cyst had a sclerotic wall with bony condensations. Aspiration cytology revealed many neutrophil leukocytes. Cyst was drained and enucleated. Histopathologically, it had a fibrous wall with inflammation and focal reactive bone formation and lined by a respiratory-type epithelium. In the clinical history, it is learned that she had a maxillary sinus surgery 8 years ago and the diagnosis was made considering the clinical and histopathological findings.

  16. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  17. Guided tissue regeneration ensures osseointegration of dental implants placed into extraction sockets. An experimental study in monkeys

    DEFF Research Database (Denmark)

    Warrer, L; Gotfredsen, K; Hjørting-Hansen, E

    1991-01-01

    on the buccal and palatal aspects of the maxillary molars in both sides of the jaw. The second molars were then extracted and self tapping titanium implants of the screw type (Astra Dental Implants) were inserted into the sockets of the largest roots. In the coronal portion of the sockets, a void was always...... present between the implant and the socket walls. In one side of the jaw, a membrane (Gore-Tex Augmentation Material) was adjusted to cover the implant. The implant in the other side of the jaw served as control and was only covered by the tissue flaps. Microscopic analysis after 3 months of healing...... technique can secure complete osseointegration of implants inserted immediately into extraction sockets....

  18. [Stimulation and evaluation on maxillary distraction osteogenesis using CASSOS 2001].

    Science.gov (United States)

    Zhu, Min; Qiu, Wei-liu; Tang, You-sheng; Li, Qing-yun

    2002-09-01

    To simulate maxillary distraction osteogenesis and evaluate the change of soft and hard tissue before and after treatment, using Computer-Assisted Simulation System for Orthognathic Surgery( CASSOS 2001). A fourteen-year-old boy with severe maxillary hypoplasia, due to unilateral cleft lip and palate, was analysed by cephalometric analysis. The simulations of maxillary distraction osteogenesis (Le Fort I osteotomy and Le Fort II osteotomy) were re-analysed. After the treatment, cephalometric analysis was preformed again. The data were compared. The maxillary hypoplasia was well treated using maxillary distraction osteogenesis; Compared with Le fort I osteotomy, more satisfactory results can be obtained by Le fort I distraction osteogenesis. Maxillary distraction osteogenesis is a better way to treat severe maxillary hypoplasia with operated CLP than maxillary osteotomy. CASSOS 2001 can help surgeons and patients on simulation and evaluation of maxillary distraction osteogenesis, and on decision of treatment plan.

  19. Aspergillus in endodontic infection near the maxillary sinus

    Directory of Open Access Journals (Sweden)

    Cinthya Cristina Gomes

    2015-10-01

    Full Text Available ABSTRACT INTRODUCTION: Diseases of the maxillary sinus have been associated with dental roots near the maxillary sinus that have undergone endodontic treatment. OBJECTIVE: To investigate the presence of filamentous fungi in patients with dental roots near the maxillary sinus who had apical periodontitis treated endodontically, and to alert practitioners that this could be a possible avenue of contamination of the sinus in patients who develop maxillary sinus infection. METHODS: Cross-sectional study in 60 palatal roots of the first maxillary molars near the maxillary sinus, that underwent endodontic treatment for apical periodontitis. After removal of the filling material, dentin shavings were collected and placed in test tubes containing Sabouraud dextrose agar and chloramphenicol. The phenotype was determined by macroscopic and microscopic examination of the colonies. For polymerase chain reaction, the primers ITS-5 and ITS-4 were used. The sequences obtained were compared with those deposited at GenBank using the Basic Local Alignment Search Tool program. RESULTS: Filamentous fungi were isolated from 6 of 60 canals (10%:Aspergillus niger (6.7%, Aspergillus versicolor (1.6%, and Aspergillus fumigatus(1.6%. CONCLUSION: Root canals near the maxillary sinus with endodontic treatment and apical periodontitis may exhibit positive cultures for filamentous fungi. Interested professionals should be alert, because these microorganisms have pathogenic characteristics that can cause disease of odontogenic origin in the maxillary sinus.

  20. Immediate occlusal loading of NanoTite™ tapered implants: a prospective 1-year clinical and radiographic study.

    Science.gov (United States)

    Östman, Pär-Olov; Wennerberg, Ann; Ekestubbe, Annika; Albrektsson, Tomas

    2013-12-01

    During the last decade, high success rates have been reported for implants placed with immediate loading procedures, especially when bone quality and quantity provide good implant stability. In many of these studies, straight-walled implants with moderately rough surfaces were employed. Tapered implants are becoming increasingly more popular due to standardized drilling protocols and reports of high initial primary stability. The aim of the present prospective, single center clinical study was to evaluate surface topographical analysis and the clinical and radiographic outcomes of the NanoTite™ (BIOMET 3i, Palm Beach Gardens, FL, USA) Tapered Implant when used for immediate loading of fixed prostheses and single-tooth restorations. Forty-two patients who needed implant treatment and met admission criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 30 Ncm prior to final seating and an implant stability quotient above 55. A total of 139 NanoTite Tapered implants (112 maxillary and 27 mandibular) were placed by one investigator, and the majority of these implants (n = 77/55%) were placed in posterior regions, and in soft bone (n = 90/65%). A total of 57 prosthetic constructions were evaluated consisting of 20 single-tooth restorations, 30 fixed partial dentures, and 7 complete, fixed maxillary restorations. Radiographs were taken at baseline and at 12 months of follow-up. Of the 139 study implants, one implant failure was declared. The overall cumulative survival rate at 1 year is 99.4%. Mean marginal bone resorption is 1.01 mm (SD 0.85) during the first year of function. Although limited to the short follow-up, immediate loading of NanoTite Tapered implants seems to be a viable option in implant rehabilitation, when insertion torque of at least 30 Ncm is achieved. Further studies are needed to authenticate the finding of this study. © 2012 Wiley

  1. REFRACTORY CEPHALEA AND RHINITIS FOLLOWING DENTAL IMPLANT

    Directory of Open Access Journals (Sweden)

    ENRIQUE COSCARÓN-BLANCO

    2018-05-01

    Full Text Available INTRODUCTION: Dental implants are prosthetic devices that are inserted into the thickness of the bone of the maxilla for osseointegration using a screw system. They are increasingly used for both functional and aesthetic reasons. As in any medical or surgical procedure, there are some typical risks and possible sequelae that must be explained and prevented. However, sometimes not-associated-with-implantation rare complications that can cause great morbidity and decrease in the quality of life of the implant recipient can occur. A case of an unusual complication is reported,MATERIAL AND METHODS: A 65-year-old woman presented with a permanent mainly right-sided bilateral nasal obstruction with frequent watery rhinorrhea and headache with retro-orbital and infraorbital irradiation refractory to broad-spectrum antibiotic treatment, corticosteroids and analgesics that she associated with a dental implant two weeks before. . Sinusitis or implant-related complication were ruled out by the dentist and her Primary Care Physician, and therefore she was referred to otorhinolaryngological assessment after radiological study with maxillary sinuses free of disease. The physical examination demostrated inferior obstructive hypertrophic turbinates from the anterior third and thick clear rhinorrhea. After topic tetracaine with adrenaline ,retraction of the turbinates revealed a screw that after breaking the floor of the right nostril entered the thickness of the inferior turbinate. In the left nostril, soil procidence is identified with turbinal contact. An orthopantomography demonstrated the findings described above, highlighting also how the implant was inserted into the skeleton of the inferior turbinate. The sympthoms resolved after removal of the implant. Topical oxymetazoline and corticosteroids provided little relief meanwhile. DISCUSSION AND CONCLUSIONS: The functional objectives sought with dental implants can be compromised by complications such as the

  2. Comparison of two protocols for maxillary protraction: bone anchors versus face mask with rapid maxillary expansion

    Science.gov (United States)

    Cevidanes, Lucia; Baccetti, Tiziano; Franchi, Lorenzo; McNamara, James A.; De Clerck, Hugo

    2010-01-01

    Objective To test the hypothesis that there is no difference in the active treatment effects for maxillary advancement induced by bone-anchored maxillary protraction (BAMP) and the active treatment effects for face mask in association with rapid maxillary expansion (RME/FM). Materials and Methods This is a study on consecutively treated patients. The changes in dentoskeletal cephalometric variables from start of treatment (T1) to end of active treatment (T2) with an average T1–T2 interval of about 1 year were contrasted in a BAMP sample of 21 subjects with a RME/FM sample of 34 patients. All subjects were prepubertal at T1. Statistical comparison was performed with t-tests for independent samples. Results The BAMP protocol produced significantly larger maxillary advancement than the RME/FM therapy (with a difference of 2 mm to 3 mm). Mandibular sagittal changes were similar, while vertical changes were better controlled with BAMP. The sagittal intermaxillary relationships improved 2.5 mm more in the BAMP patients. Additional favorable outcomes of BAMP treatment were the lack of clockwise rotation of the mandible as well as a lack of retroclination of the lower incisors. Conclusions The hypothesis is rejected. The BAMP protocol produced significantly larger maxillary advancement than the RME/FM therapy. PMID:20578848

  3. Stresses generated by two zygomatic implant placement techniques associated with conventional inclined anterior implants

    Directory of Open Access Journals (Sweden)

    Paulo H.T. Almeida

    2018-06-01

    Full Text Available Purpose: To make a comparative evaluation, by means of the finite element method, of the stress generated on supporting tissues and prosthetic system components, using zygomatic implants with the exteriorized and extramaxillary techniques, and different placement positions, associated either with inclined anterior implants, or those without inclination. Materials and methods: Eight (8 tridimensional models were created to represent the clinical situations being researched, using the dataset of scanned images of an edentulous model. The implants and prosthetic components were photographed on millimeter paper and inserted into Rhinoceros 3D modeling computer software. From the measurements made on the image, the virtual models were made. The application force was distributed on the occlusal surface of the working side of the left maxillary first molar, first and second premolars, and incisal regions of the central incisor, simulating the occlusal load during mastication, in a total of 150 N. Results: The extramaxillary technique presented considerable variation in increased tension on the prosthesis screws and bone tissue. In the exteriorized technique, the highest tension values occurred in the region of the ridge, and the lowest, on the zygomatic process; the absence of cantilever reduced the stress on bone tissue in almost all regions. Conclusion: The exteriorized technique was shown to be more favorable to the distribution of stresses on the micro-unit screws and bone tissue, with the model with zygomatic implant placed in the region of the first molar and inclined anterior implant presenting the best results. Keywords: Zygomatic implants, Atrophic maxilla, Finite element analysis, Cantilever, Inclined implant

  4. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    Science.gov (United States)

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  5. Hemiepiphysiodesis Implants for Late-onset Tibia Vara: A Comparison of Cost, Surgical Success, and Implant Failure.

    Science.gov (United States)

    Funk, Shawn S; Mignemi, Megan E; Schoenecker, Jonathan G; Lovejoy, Steven A; Mencio, Gregory A; Martus, Jeffrey E

    2016-01-01

    The purpose of this study was to compare hemiepiphysiodesis implants for late-onset tibia vara and to evaluate patient characteristics that may predict surgical failure. This is a retrospective review of late-onset tibia vara patients treated with temporary hemiepiphysiodesis from 1998 to 2012. Mechanical axis deviation (MAD), mechanical axis angle, mechanical lateral distal femoral angle, and medial proximal tibial angle were measured on standing bone length radiographs. Surgical failure was defined as residual deformity requiring osteotomy, revision surgery, or MAD exceeding 40 mm at the time of final follow-up. Implant failure was recorded. Costs included implants and disposables required for construct placement. Staple constructs included 2 or 3 staples. Plate constructs included the plate, screws, guide wires, and drill bits. A total of 25 patients with 38 temporary lateral proximal tibia hemiepiphysiodeses met the inclusion criteria. The average body mass index (BMI) was 39.1 kg/m with an average follow-up of 3.0 years (minimum 1 y). Surgical failure occurred in 57.9% of patients. Greater BMI (P=0.05) and more severe deformity (MAD, mechanical axis angle, and medial proximal tibial angle; Pfailure. Younger age predicted higher rates of implant failure (Pfailure between staple and plate systems. Hospital costs of plate constructs ($781 to $1244) were 1.5 to 3.5 times greater than the staple constructs ($332 to $498). Greater BMI, more severe deformity, and younger age were predictive of surgical or implant failure. There was no difference in success between implant types, whereas the cost of plate constructs was 1.5 to 3.5 times greater than staples. The rate of surgical failure was high (58%) and consideration should be given to reserving hemiepiphysiodesis for patients with lower BMI and less severe deformity. In our population, if hemiepiphysiodesis was not offered to patients with BMI>35 or MAD>80 mm varus, the surgical failure rate would diminish to 28

  6. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position.

    Science.gov (United States)

    Jensen, Charlotte; Raghoebar, Gerry M; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S

    2016-12-01

    To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Thirty subjects with a bilateral unbounded posterior saddle received 2 PM and 2M implants. A new RPD was placed. Implant support was provided 3 months later. Two PM implants supported the RPD. After 3 months the 2M implants were used or vice versa. Outcome measures included oral health related quality of life (OHIP-NL49), general health status (SF-36), contentment assessed on a Visual Analogue Scale (VAS) and the number of hours that the RPD was worn. Data were collected prior to treatment, 3 months after having functioned with a new RPD and after 3 and 6 months with implant support. Finally, patients expressed their preferred implant position. The general health status (SF-36) was not influenced. OHIP-NL49 values and mean wearing-time were statistical significantly more favorable for ISRPD's, regardless of the implant position. Per day, the ISRPD's were worn 2-3h more than the unsupported new RPD. Patients' expectations were met as the VAS-scores of anticipated and realized contentment did not reach a statistical significant level (p>0.05). VAS scores for ISRPD's with M implant support were higher than for PM implant support. Finally, 56.7% of subjects preferred the M implant support, 13.3% expressed no preference and 30% opted for PM implant support. Mandibular implant support favorably influences oral health related patient-based outcome measures in patients with a bilateral free-ending situation. The majority of patients prefer the implant support to be in the molar region. Patients with a bilateral free-ending situation in the mandible opposed by a maxillary denture benefit from implant support to their mandibular removable partial denture. Most patients prefer this support to be in the molar region. Copyright © 2016

  7. Congenitally Missing Maxillary Lateral Incisors: Update on the Functional and Esthetic Parameters of Patients Treated with Implants or Space Closure and Teeth Recontouring

    Science.gov (United States)

    Pini, Núbia Inocencya Pavesi; Marchi, Luciana Manzotti De; Pascotto, Renata Corrêa

    2015-01-01

    Maxillary lateral incisor agenesis (MLIA) is a condition that affects both dental esthetics and function in young patients, and represents an important challenge for clinicians. Although several treatment options are available, the mesial repositioning of the canines followed by teeth recontouring into lateral incisors; or space opening/maintenance followed by implant placement have recently emerged as two important treatment approaches. In this article, the current and latest literature has been reviewed in order to summarize the functional and esthetic outcomes obtained with these two forms of treatment of MLIA patients in recent years. Indications, clinical limitations and the most important parameters to achieve the best possible results with each treatment modality are also discussed. Within the limitations of this review, it is not possible to assert at this point in time that one treatment approach is more advantageous than the other. Long-term followup studies comparing the existing treatment options are still lacking in the literature, and they are necessary to shed some light on the issue. It is possible, however, to state that adequate multidisciplinary diagnosis and planning are imperative to define the treatment option that will provide the best individual results for patients with MLIA. PMID:25646137

  8. Early implant placement for a patient with ectodermal dysplasia: Thirteen years of clinical care.

    Science.gov (United States)

    Knobloch, Lisa A; Larsen, Peter E; Saponaro, Paola C; L'Homme-Langlois, Emilie

    2017-11-29

    Patients with ectodermal dysplasia have abnormalities of 2 or more structures that originate from the ectoderm. The oral manifestations often include the congenital absence of teeth and malformed teeth. This clinical report describes the interdisciplinary care from childhood through the definitive dental rehabilitation completed at skeletal maturation to replace the missing teeth in a patient with ectodermal dysplasia. Treatment began at 9 years of age with an implant-assisted mandibular overdenture to improve function and replace the missing mandibular teeth. Orthodontic treatment for the consolidation of space, composite resin restorations, and interim removable dental prostheses were provided to improve esthetics and replace the missing maxillary teeth. Skeletal growth was monitored, and orthognathic surgery was performed at the cessation of growth. The definitive rehabilitation consisted of a mandibular fixed dental prosthesis supported by dental implants and a maxillary removable dental prosthesis to restore the patient to esthetics and function. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Camouflage of Severe Skeletal Class II Gummy Smile Patient Treated Nonsurgically with Mini Implants

    Directory of Open Access Journals (Sweden)

    Irfan Qamruddin

    2014-01-01

    Full Text Available Skeletal class II has always been a challenge in orthodontics and often needs assistance of surgical orthodontics in nongrowing patients when it presents with severe discrepancy. Difficulty increases more when vertical dysplasia is also associated with sagittal discrepancy. The advent of mini implants in orthodontics has broadened the spectrum of camouflage treatment. This case report presents a 16-year-old nongrowing girl with severe class II because of retrognathic mandible, and anterior dentoalveolar protrusion sagittally and vertically resulted in severe overjet of 13 mm and excessive display of incisors and gums. Both maxillary central incisors were trimmed by general practitioner few years back to reduce visibility. Treatment involved use of micro implant for retraction and intrusion of anterior maxillary dentoalveolar segment while lower incisors were proclined to obtain normal overjet, and overbite and pleasing soft tissue profile. Smile esthetics was further improved with composite restoration of incisal edges of both central incisors.

  10. Histomorhological and clinical evaluation of maxillary alveolar ridge reconstruction after craniofacial trauma by applying combination of allogeneic and autogenous bone graft

    Directory of Open Access Journals (Sweden)

    Francesco Saverio De Ponte

    2017-02-01

    Full Text Available A variety of techniques and materials for the rehabilitation and reconstruction of traumatized maxillary ridges prior to dental implants placement have been described in literature. Autogenous bone grafting is considered ideal by many researchers and it still remains the most predictable and documented method. The aim of this report is to underline the effectiveness of using allogeneic bone graft for managing maxillofacial trauma. A case of a 30-year-old male with severely atrophic maxillary ridge as a consequence of complex craniofacial injury is presented here. Augmentation procedure in two stages was performed using allogeneic and autogenous bone grafts in different areas of the osseous defect. Four months after grafting, during the implants placement surgery, samples of both sectors were withdrawn and submitted to histological evaluation. On the examination of the specimens, treated by hematoxylin and eosin staining, the morphology of integrated allogeneic bone grafts was revealed to be similar to the autologous bone. Our clinical experience shows how the allogeneic bone graft presented normal bone tissue architecture and is highly vascularized, and it can be used for reconstruction of severe trauma of the maxilla.

  11. A 3-year follow-up study of overdentures retained by mini-dental implants.

    Science.gov (United States)

    Preoteasa, Elena; Imre, Marina; Preoteasa, Christina Teodora

    2014-01-01

    This study evaluated overdentures retained by mini-dental implants (MDIs) as a treatment option for complete edentulism during a 3-year follow-up period. This observational clinical study included completely edentulous patients who were treated with MDI-retained overdentures. The MDIs were supplied by the manufacturer. Twenty-three patients received 7 maxillary and 16 mandibular MDI overdentures retained by 110 MDIs. Of the 36 MDIs placed in the maxilla, 8 failed (in two patients), 2 had compromised survival, 3 displayed satisfactory survival, and 23 were successful. Of the 74 MDIs placed in the mandible, 11 displayed satisfactory survival and 63 were successful. The marginal bone loss was more pronounced for the MDIs placed mesially (intercalated), in areas of decreased ridge width and bone density, and with lower values of insertion torque. The overdentures fractured in seven patients; in 4 of them, this corresponded to the implant housing area. Self-reported reasons for patient dissatisfaction included occasional pain under the overdenture (n = 5) and instability of the maxillary antagonist complete denture (n = 4). Based on this research, considering its limitations, it is possible to conclude that survival rates and health status are better for MDI overdentures applied in the mandible than for those applied in the maxilla. The most severe prosthetic complications encountered were overdenture base fracture, matrix detachment, and instability of the maxillary antagonist denture.

  12. Surgically assisted rapid maxillary expansion in adults.

    Science.gov (United States)

    Pogrel, M A; Kaban, L B; Vargervik, K; Baumrind, S

    1992-01-01

    Twelve adults with maxillary width discrepancy of greater than 5 mm were treated by surgically assisted rapid maxillary expansion. The procedure consisted of bilateral zygomatic buttress and midpalatal osteotomies combined with the use of a tooth-borne orthopedic device postoperatively. Mean palatal expansion of 7.5 mm (range of 6 to 13 mm), measured in the first molar region, was achieved within 3 weeks in all patients. Expansion remained stable during the 12-month study period, with a mean relapse for the entire group of 0.88 +/- 0.48 mm. Morbidity was limited to mild postoperative discomfort. The results of this preliminary study indicated that surgically assisted rapid maxillary expansion is a safe, simple, and reliable procedure for achieving a permanent increase in skeletal maxillary width in adults. Further study is necessary to document the three-dimensional movements of the maxillary segments and long-term stability of the skeletal and dental changes.

  13. Long-term Stability of Soft Tissue Esthetic Outcomes Following Conventional Single Implant Treatment in the Anterior Maxilla: 10-12 Year Results.

    Science.gov (United States)

    Rokn, A; Bassir, S H; Rasouli Ghahroudi, A A; Kharazifard, M J; Manesheof, R

    2016-01-01

    The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6-14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term.

  14. Alignment Strategy for Constricted Maxillary Dental Arch in Patients With Unilateral Cleft Lip and Palate Using Fixed Orthodontic Appliance.

    Science.gov (United States)

    Park, Yoon-Hee; Park, Sumin; Baek, Seung-Hak

    2018-03-01

    The purpose of this study was to compare the alignment pattern of the constricted maxillary dental arch by fixed orthodontic treatment (FOT) in the well-aligned and constricted arches of unilateral cleft lip and palate (UCLP) patients. 19 UCLP patients were divided into Group 1 (well-aligned arch, n = 9) and Group 2 (constricted arch, n = 10). After the cephalometric and maxillary dental arch variables before (T1) and after FOT (T2) were measured, statistical analysis was performed. There were no significant differences in the surgical timing of cheiloplasty, palatoplasty, and secondary alveolar bone grafting and in the surgical method of cheiloplasty between the 2 groups. However, Group 2 had a higher percentage of palatoplasty method, which could leave the denuded bone for secondary healing than Group 1 (P dental arch compared to Group 1 at the T1 stage (inter-second premolar width, greater segment angle [GSA], and lesser segment angle [LSA], all P dental arch shape, different strategy is necessary to obtain proper alignment by FOT.

  15. A case report of mucoid retention cyst in maxillary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Pyoung [College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1973-11-15

    The author have observed mucoid retention cyst in the right maxillary sinus of the patient, 41 year old woman, complained discharging of purulent exudate on the right maxillary molar area, and obtained the following conclusions; 1. The mucoid retention cyst in maxillary sinus casts a faint dome shaped shadow into the radiolucent image of maxillary sinus. 2. The mucoid retention cyst in maxillary sinus may occurred without the history of trauma. 3. Intraoral standard films are also valuable for the interpretation of the lesions in maxillary sinus but only extraoral roentgenograms.

  16. Immediate non-occlusal loading of single implants in the aesthetic zone : A randomized clinical trial

    NARCIS (Netherlands)

    den Hartog, Laurens; Raghoebar, Gerry M.; Stellingsma, Kees; Vissink, Arjan; Meijer, Henny J. A.

    P>Aim This study compared the outcome of immediate non-occlusal loading with conventional loading for single implants in the maxillary aesthetic zone. It was hypothesized that immediate non-occlusal loading is not inferior to conventional loading. Materials and Methods Sixty-two patients with a

  17. Assessment of implant stability during various stages of healing placed immediately following extraction in an overdenture situation

    Directory of Open Access Journals (Sweden)

    Ashwin Thomas Koshy

    2017-01-01

    Full Text Available To assess the implant stability during different stages of healing in an immediate loaded implant soon after extraction. A 73-year-old female came with a chief complaint of bad smell and irritation in her lower front gum region. On examination, she was found to be completely edentulous in the maxillary arch and partially edentulous in the mandibular arch with only the canines present bilaterally. The posterior mandibular ridge was severely resorbed and hence could not be treated with a conventional mandibular complete denture. Considering the age of the patient and the preference of only a single surgical visit, we decided to plan for a conventional maxillary denture against an implant supported mandibular overdenture with two implants placed immediately after extraction of canines. The stability of these implants was assessed during the early phases of healing with the help of a resonance frequency analysis method (RFA using Osstell ISQ™. During the healing phase, implant stability quotient (ISQ values decrease by 4–5 values after installation with the lowest values at the 1st week postplacement. Following this, the ISQ values increased steadily for all implants up to 16 weeks. No significant differences were noted over time. At placement, the mean ISQ values at 33 and 43 regions were 74 and 75.2, respectively. The mean lowest ISQ values recorded at the 1st week were 58.8 and 65.4, respectively. At 16 weeks, the mean ISQ values were 70.5 and 67.9, respectively. The survival of such immediately placed implants, which are later used as overdenture supported implants, are highly predictable when the surgical and prosthetic part is done meticulously. However, there needs future studies oriented to understand better the healing pattern of immediately placed implants in extraction sockets, which would guide the clinician with the optimal loading time.

  18. Aspergillus in endodontic infection near the maxillary sinus.

    Science.gov (United States)

    Gomes, Cinthya Cristina; Pinto, Larissa Christina Costa; Victor, Fernanda Loretti; Silva, Erlange Andrade Borges da; Ribeiro, Apoena de Aguiar; Sarquis, Maria Inês de Moura; Camões, Isabel Coelho Gomes

    2015-01-01

    Diseases of the maxillary sinus have been associated with dental roots near the maxillary sinus that have undergone endodontic treatment. To investigate the presence of filamentous fungi in patients with dental roots near the maxillary sinus who had apical periodontitis treated endodontically, and to alert practitioners that this could be a possible avenue of contamination of the sinus in patients who develop maxillary sinus infection. Cross-sectional study in 60 palatal roots of the first maxillary molars near the maxillary sinus, that underwent endodontic treatment for apical periodontitis. After removal of the filling material, dentin shavings were collected and placed in test tubes containing Sabouraud dextrose agar and chloramphenicol. The phenotype was determined by macroscopic and microscopic examination of the colonies. For polymerase chain reaction, the primers ITS-5 and ITS-4 were used. The sequences obtained were compared with those deposited at GenBank using the Basic Local Alignment Search Tool program. Filamentous fungi were isolated from 6 of 60 canals (10%): Aspergillus niger (6.7%), Aspergillus versicolor (1.6%), and Aspergillus fumigatus (1.6%). Root canals near the maxillary sinus with endodontic treatment and apical periodontitis may exhibit positive cultures for filamentous fungi. Interested professionals should be alert, because these microorganisms have pathogenic characteristics that can cause disease of odontogenic origin in the maxillary sinus. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Impact of platform switching on inter-proximal bone levels around 8.5 mm implants in the posterior region; 5-year results from a randomized clinical trial

    NARCIS (Netherlands)

    Telleman, Gerdien; Raghoebar, Gerry M.; Vissink, Arjan; Meijer, Henny J. A.

    Aim: To assess the medium- term results of 8.5 mm implants supplied with a conventional platform- matched implant- abutment connection or a platform- switched design. Materials and Methods: Eighty patients with one or more missing teeth in the maxillary or mandibular posterior zone were randomly

  20. Monte Carlo simulation of boron-ion implantation into single-crystal silicon

    International Nuclear Information System (INIS)

    Klein, K.M.

    1991-01-01

    A physically based Monte Carlo boron implantation model developed comprehends previously neglected but important implant parameters such as native oxide layers, wafer temperature, beam divergence, tilt angle, rotation (twist) angle, and dose, in addition to energy. This model uses as its foundation the MARLOWE Monte Carlo simulation code developed at Oak Ridge National Laboratory for the analysis of radiation effects in materials. This code was carefully adapted for the simulation of ion implantation, and a number of significant improvements have been made, including the addition of atomic pair specific interatomic potentials, the implementation of a newly developed local electron concentration dependent electronic stopping model, and the implementation of a newly developed cumulative damage model. This improved version of the code, known as UT-MARLOWE, allows boron implantation profiles to be accurately predicted as a function of energy, tilt angle, rotation angle, and dose. This code has also been used in the development and implementation of an accurate and efficient two-dimensional boron implantation model

  1. Hard and Soft Tissue Changes Following Maxillary Distraction Osteogenesis and Mandibular Setback with Bilateral Sagittal Split Osteotomy.

    Science.gov (United States)

    Bawane, Shilpa S; Andrade, Neelam N

    2016-12-01

    (1) To highlight the role of intraoral submerged device in distraction osteogenesis (DO) of patients requiring two jaw surgeries for the correction of severe developmental maxillary hypoplasia (MH) and mandibular prognathism (MP) (2) To analyse the hard and soft tissue changes following maxillary DO and mandibular setback with bilateral sagittal split osteotomy (BSSO) in patients with severe MH and MP requiring two jaw surgeries. During the period Jan 2004 to Dec 2006, five patients with severe developmental MH along with MP were treated. In 1st stage maxillary distraction was done. Distraction started on 6th postoperative day, 1 mm distraction was carried out for 10-15 days on either side. Serial radiographs were taken immediate postoperative period for baseline comparison, post-distraction and at the end of distraction. After a period of 3-4 months of distraction 2nd stage was done. In 2nd stage, mandibular setback was done with BSSO and distractors were removed under general anesthesia. Radiographs were taken immediately and at 4 months post-operatively. Cephalometric tracings were carried out preoperatively, post DO and finally after mandibular setback with BSSO. The mean horizontal movement of maxilla was 11.4 mm at ANS and 9.6 mm at A point. Upper incisor edge was advanced by 8.8 mms. SNA increased by 8.4° and SNB decreased by 4.6°. Nasal projection advanced by 4°. Nasolabial angle normalized in all patients, mean change achieved was 10.8°. Upper lip moved forward by 5.4 mm. Lower lip moved backward by 5.4 mm. Mandible positioned backward by 4 mm at B point. No vertical change occurred in the position of A, ANS and upper incisor edges. Mean increase in skeletal angle of convexity was 26.4°. Concave profile was significantly changed to convex in all patients. Maxillary DO and mandibular setback with BSSO was associated with improved facial balance and esthetics.

  2. Breakage of internal maxillary distractor: considerable complication of maxillary distraction osteogenesis.

    Science.gov (United States)

    Aikawa, Tomonao; Iida, Seiji; Isomura, Emiko T; Namikawa, Mari; Matsuoka, Yudai; Yamada, Chiaki; Yamamoto, Taku; Takigawa, Yoko

    2008-07-01

    Maxillary distraction osteogenesis using intraoral distractors is now one of the standard treatments of maxillary retrusion. This report shows 2 cases of breakage of this internal maxillary distractor in patients with cleft lip and palate; one was observed during the distraction period and the other was during the retention period. The first case required a rotational movement of the distraction segment, and this movement caused the laterally dislocation of the posterior part of the distractor, where the distractor suffered some mechanical forces by mouth opening. In the latter case, breakage of distractor was observed on the radiographs taken 3 months after distraction and this complication may have been caused by mechanical force by occlusion and mastication. Both breakages were found at the joint of the anchorage plate and the extension rod, which has some flexibility for adjusting the plate to the bone surface. Therefore, surgeons should pay special attention for this mechanical weak area in this distractor not only during the advancement period, but also during the retention period and should avoid unnecessary frequent bending for adopting the bone surface, which directly weakens the joint.

  3. A Semi-automatic Algorithm for Preliminary Assessment of Labial Gingiva and Alveolar Bone Thickness of Maxillary Anterior Teeth.

    Science.gov (United States)

    Chen, Sheng-Hong; Chan, Hsun-Liang; Lu, Yongning; Ong, Sim-Heng; Wang, Hom-Lay; Ko, Eng Hong; Chang, Po-Chun

    Soft and hard tissue volumes are critical for implant placement and long-term stability. Although the literature has adequately addressed tissue biotypes of Western populations, pertinent information about Asian populations is limited. This study aimed to evaluate the soft and hard tissue profiles of the maxillary anterior teeth of the Taiwanese population using a semi-automatic algorithm. Cone beam computed tomography images of 11 adults with well-aligned maxillary anterior teeth were overlaid with those of cast models, based on the tooth crowns manually outlined by two independent observers. Each tooth was digitally trisected mesiodistally and apicocoronally. The thicknesses of the labial gingiva and alveolar bone were measured using a customized software program. No obvious difference between the observers was noted regarding the dimension of tooth crowns. The average thicknesses of the labial gingiva, the labial alveolar bone, and the palatal alveolar bone were 1.76 ± 0.11 mm, 1.02 ± 0.12 mm, and 1.80 ± 0.31 mm, respectively, with no significant differences between teeth. All parameters were thicker in the apical region than in the cervical region, and the alveolar bone was thinner in the midlabial region of incisors than in the interproximal regions. The thinnest areas were the midcervical compartment of the right central incisor (0.53 ± 0.33 mm) for the labial gingiva, the midcervical compartment of the right lateral incisor (0.23 ± 0.10 mm) for the labial alveolar bone, and the mesiocervical compartment of the left central incisor (0.33 ± 0.09 mm) for the palatal alveolar bone. This study presents an objective and comprehensive methodology for evaluating the soft and hard tissue profiles of maxillary anterior teeth and may be of value for presurgical planning for immediate implant placement. The results suggest that profiles of the Taiwanese subjects are similar to profiles of Western populations.

  4. Volumetric measurement of the maxillary sinus by coronal CT scan

    International Nuclear Information System (INIS)

    Ikeda, Atsuko

    1996-01-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  5. Volumetric measurement of the maxillary sinus by coronal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1996-08-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  6. Crecimiento sagital maxilar en fisurados unilaterales operados funcionalmente Sagittal maxillary growth in unilateral cleft lip and palate patients following functional surgery

    Directory of Open Access Journals (Sweden)

    F. Donoso Hofer

    2007-06-01

    Full Text Available Objetivo. Comparar el crecimiento sagital maxilar en pacientes con fisura labio-máxilo-palatina unilateral operados a los 6 meses con criterio funcional con pacientes normales que tengan relación consanguínea directa con los anteriores. Diseño del estudio. Análisis arquitectural y craneofacial de Delaire en telerradiografías de perfil en ambos grupos de pacientes cuyas edades fluctúan actualmente entre los 7 y los 12 años, determinando el crecimiento sagital del maxilar a través de la medida del ángulo del pilar maxilar anterior (C1/F1, sometiendo las medidas al test T de Student con una significación del 99,5%. Resultados.Se determinó el valor real y esperado para el ángulo del pilar maxilar anterior en todos los casos. Al comparar estadísticamente los resultados, no se encontraron diferencias significativas en los valores promedios obtenidos. Conclusiones.El crecimiento sagital maxilar de los pacientes con fisura labio-máxilo-palatina unilateral operados a los 6 meses con criterio funcional no difiere del de aquellos pacientes normales.Objective. To compare the sagittal maxillary growth between unilateral cleft lip and palate patients operated under functional criterion at the age of 6 months and normal patients who were blood-related. Design. Delaire’s Architectural and Structural craniofacial analysis in conventional lateral radiographs of all the patients with an age range of 7-12 years, determining the sagittal maxillary growth by the anterior maxillary pillar angle (C1/F1. These measurements were analyzed using the T-test with a 99.5% significance. Results. The real and expected value of the anterior maxillary pillar angle was determined in all cases. By comparing the results statistically, no significant differences were found in the mean values obtained. Conclusion. Maxillary sagittal growth in unilateral cleft lip and palate patients operated at the age of 6 months under functional criterion, does not differ from the

  7. endodontic treatment of unusually long discolored maxillary central ...

    African Journals Online (AJOL)

    a few cases of dual–rooted maxillary central incisor have been reported in literature1-5. Maxillary central incisors vary in root ... The following case report describes the endodontic management of a patient with an unusually long maxillary central incisor in our environment. CASE PROFILE. A 31 year-old male was referred ...

  8. Implant rehabilitation in fibula-free flap reconstruction: A retrospective study of cases at 1-18 years following surgery.

    Science.gov (United States)

    Sozzi, Davide; Novelli, Giorgio; Silva, Rebeka; Connelly, Stephen T; Tartaglia, Gianluca M

    2017-10-01

    To determine the dental implant and prostheses success rate in a cohort of patients who underwent a vascularized fibula-free flap (FFF) for maxillary or mandibular reconstruction. The investigators implemented a retrospective cohort study composed of patients who had undergone primary or secondary FFF reconstruction jaw surgery plus placement of 2-6 implants in the reconstructed arch, which were restored with an implant-supported prosthesis. The sample was composed of all patients who underwent FFF surgery between 1998 and 2012 and had either simultaneous or secondary dental implant placement. A total of 28 patients met inclusion criteria. Of these, 22 patients participated in the retrospective review. Patients were examined by an independent observer between January-December 2015. In addition, all patients completed a questionnaire to access satisfaction with the implant-supported prosthesis. The patient cohort consisted of 12 males and 10 females, age 12-70 years. A total of 100 implants were placed, 92 implants in fibular bone and 8 implants in native bone. In the maxilla, 35 implants were placed into fibular bone and 4 into native bone (11 in irradiated patients and 28 in non-irradiated patients). In the mandible, 57 implants were placed into fibular bone and 4 into native bone (15 in irradiated patients and 46 in non-irradiated patients). The mean follow-up after implant loading was 7.8 years (range 1.3-17.5 years). The implant survival rate was 98% (95% CI: 92.2%-99.5%). No statistically significant difference was found in implant success between maxillary and mandibular implants, or between radiated and non-radiated bone. The prostheses success rate, determined by clinical exam and patient satisfaction, was 100%. The results of this study suggest that implant survival is high and implant-supported prostheses are a reliable rehabilitation option in patients whose jaws have been reconstruction with a FFF. Copyright © 2017. Published by Elsevier Ltd.

  9. Biting Force and Muscle Activity in Implant-Supported Single Mandibular Overdentures Opposing Fixed Maxillary Dentition.

    Science.gov (United States)

    Al-Magaleh, Wafaʼa R; Abbas, Nadia A; Amer, Ashraf A; Abdelkader, Ann A; Bahgat, Basma

    2016-04-01

    This study aimed to investigate the relation between biting force and masticatory muscle activity in patients treated by 3 modalities of single mandibular dentures. Forty implants were placed in 10 patients with completely edentulous mandibles. The study was divided into 3 treatment stages. Initially, each patient received a conventional mandibular complete denture. At the second stage, 4 mandibular implants were placed and the denture was refitted to their abutments. Third stage comprised connecting the denture to the implants through ball attachments. During each treatment stage, maximum biting force and muscle activity were measured during maximum clenching and chewing of soft and hard food. Biting force demonstrated a statistically significant increase by time for the 3 treatment stages. The highest muscle activity was recorded for the conventional denture followed by the implant-supported overdenture without attachment, whereas the lowest values were recorded for the implant-supported overdenture with attachment. Biting force was related mainly to the quality of denture support. Muscle activity was higher in patients with conventional denture than with implant-supported prostheses (with or without attachments).

  10. Influence of implant rod curvature on sagittal correction of scoliosis deformity

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Tadano, Shigeru; Abe, Yuichiro

    2014-01-01

    of the implant rod’s angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. STUDY DESIGN: A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. PATIENT SAMPLE: Twenty adolescent idiopathic......BACKGROUND CONTEXT: Deformation of in vivo–implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. PURPOSE: To analyze the changes...... scoliosis patients underwent surgery. Average age at the time of operation was 14 years. OUTCOME MEASURES: The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. METHODS: Two implant rods were attached to the concave and convex side...

  11. Pansinusitis y afectación intracraneal por implante dental Pansinusitis and intracranial impact of a dental implant

    Directory of Open Access Journals (Sweden)

    Josep Rubio-Palau

    2012-03-01

    Full Text Available Las sinusitis odontógenas son una patología relativamente frecuente causada por infecciones dentales, quistes periapicales así como tras procedimientos bucodentales como una endodoncia, una elevación sinusal o la colocación de un implante. A continuación se presenta un caso extremo de una pansinusitis derecha con fistulización a espacio epidural causada por un implante osteointegrado. Ante la sospecha de una sinusitis maxilar de origen odontogénico se debe iniciar rápidamente un tratamiento antibiótico correcto y un seguimiento estrecho ya que pueden tener consecuencias fatales como la pérdida de un ojo, abscesos cerebrales o incluso la muerte.Odontogenic sinusitis is a relatively common disease caused by dental infections, periapical cysts and oral procedures such as root canal, sinus lift or implant placement. We report an extreme case of a right pansinusitis with an epidural space fistula caused by osseointegrated implants. When maxillary sinusitis of odontogenic origin is suspected, we should quickly start effective antibiotic treatment and monitor the patient closely because odontogenic sinusitis can have serious consequences, such as the loss of an eye, brain abscess or death.

  12. Immediate occlusal loading of NanoTite PREVAIL implants: a prospective 1-year clinical and radiographic study.

    Science.gov (United States)

    Ostman, Pär-Olov; Wennerberg, Ann; Albrektsson, Tomas

    2010-03-01

    Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.

  13. Ability of mini-implant-facilitated micro-osteoperforations to accelerate tooth movement in rats.

    Science.gov (United States)

    Cheung, Tracy; Park, Juyoung; Lee, Deborah; Kim, Catherine; Olson, Jeffrey; Javadi, Shadi; Lawson, Gregory; McCabe, James; Moon, Won; Ting, Kang; Hong, Christine

    2016-12-01

    Although current techniques for accelerated tooth movement often involve invasive surgical procedures, micro-osteoperforations (MOPs) using mini-implants may facilitate orthodontic tooth movement without raising flaps, reduce surgical risks, and increase patient acceptance. In this study, we evaluated the effectiveness of mini-implant-facilitated MOPs in inducing accelerated tooth movement and investigated the potential risks for root resorption. Five MOPs were placed on the left side around the maxillary first molars in 6 rats using an automated mini-implant driver, whereas the right side received no MOPs as the control. Closed-coiled springs were secured from incisors to first molars for orthodontic tooth movement. Tooth movement was measured, and samples underwent radiologic and histologic analyses. The MOP side exhibited a 1.86-fold increase in the rate of tooth movement with decreased bone density and bone volume around the first molars compared with the control side. Hematoxylin and eosin and tartrate-resistant acid phosphatase analyses showed increased numbers of osteoclasts as well as new bone formation. Three-dimensional volumetric analysis of all 5 roots of the maxillary first molars demonstrated no statistically significant difference in root volumes. Mini-implant-facilitated MOPs accelerated tooth movement without increased risk for root resorption and therefore may become a readily available and efficient treatment option to shorten orthodontic treatment time with improved patient acceptance. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. The use of internal maxillary distraction for maxillary hypoplasia: a preliminary report.

    Science.gov (United States)

    Van Sickels, Joseph E; Madsen, Mathew J; Cunningham, Larry L; Bird, Douglas

    2006-12-01

    Distraction osteogenesis is a useful alternative to advance the maxilla in complicated cases of maxillary hypoplasia. The purpose of this article is to review the workup, experience, and preliminary results with the use of internal distraction osteogenesis for maxillary hypoplasia at one teaching institution. Over a 5-year period, more than 300 patients with craniofacial and dentofacial defects have undergone oral and maxillofacial surgery at our center to correct their skeletal discrepancies. Of these, 10 have had maxillary distraction osteogenesis done with internal distractors. Follow-up of 6 months or more was available for 8 patients. Stereolithographic models were used to bend distractors prior to surgery in 6 patients. Latency prior to the start of distraction was 3 to 7 days and varied with the age of the patient. Distraction occurred at approximately 1 mm per day with an average distraction length of 8.5 mm (range, 6-10 mm). Excellent occlusal results were obtained in 5 patients. Major complications including nonunion and failure to achieve acceptable occlusal results were observed in 3 patients. Minor complications including pain and loosening of the distracter devices were observed in 2 patients, but did not appear to affect the esthetic and functional results. Distraction osteogenesis is a useful alternative to traditional orthognathic surgery to treat maxillary hypoplasia. Internal distractions are attractive to patients, but are more difficult to place and can cause discomfort to patients when trying to achieve an ideal primary vector of distraction. Stereolithographic models can help with placement of the device. Changes in design of distractors may help with patient discomfort.

  15. Maxillary unicystic ameloblastoma: a case report.

    Science.gov (United States)

    Agani, Zana; Hamiti-Krasniqi, Vjosa; Recica, Jehona; Loxha, Mergime Prekazi; Kurshumliu, Fisnik; Rexhepi, Aida

    2016-10-18

    Ameloblastoma is a benign epithelial odontogenic tumor. It is often aggressive and destructive, with the capacity to attain great size, erode bone and invade adjacent structures. Unicystic ameloblastoma is a rare odontogenic lesion, with clinical, radiographic and gross features of jaw cysts. The lesion histologically shows typical ameloblastomatous epithelium lining part of the cyst cavity with or without and/or mural tumor growth. Unicystic ameloblastoma usually presents in posterior mandibular ramus region, while it is rare and atypical in posterior maxillary region. . We report a case of 16 year old Kosovar male, Albanian ethnicity, who presented with a swelling located in right maxillary region. Clinical examination revealed a painless swelling extending from the maxillary right central incisor to the maxillary right first molar tooth. Panoramic radiograph disclosed a well corticated unilocular radiolucent lesion approximately 5 × 5 cm in diameter which was in contact with the roots of the teeth present inferiorly and with the maxillary sinus superiorly. Maxillary right canine impaction was noted and unerupted lateral incisor tooth was present inside the radiolucency. Preoperative diagnosis of the lesion was made as dentigerous cyst based on the age of the patient, location of the swelling, clinical and radiographic findings, but the unicystic ameloblastoma was also taken into consideration. The patient was treated by surgical enucleation of the lesion and extraction of lateral incisor tooth which was present inside the lesion. The histopathological examination of the lesion revealed confirmed finding for unicystic ameloblastoma mural form. No recurrence was observed in 1 year follow-up. Maxillary region is considered a rare and atypical location for unicystic ameloblastoma. We emphasize the importance of differential diagnosis of an odontogenic lesion with common clinical and radiological features that will impact the treatment planning and follow up

  16. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    Science.gov (United States)

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  17. Maxillary sinus floor extension and posterior tooth inclination in adolescent patients with Class II Division 1 malocclusion treated with maxillary first molar extractions

    NARCIS (Netherlands)

    Livas, Christos; Halazonetis, Demetrios J.; Booij, Johan Willem; Pandis, Nikolaos; Tu, Yu-Kang; Katsaros, Christos

    Introduction: Our objective was to investigate potential associations between maxillary sinus floor extension and inclination of maxillary second premolars and second molars in patients with Class II Division 1 malocclusion whose orthodontic treatment included maxillary first molar extractions.

  18. Maxillary sinus floor extension and posterior tooth inclination in adolescent patients with Class II Division 1 malocclusion treated with maxillary first molar extractions

    NARCIS (Netherlands)

    Livas, C.; Halazonetis, D.J.; Booij, J.W.; Pandis, N.; Tu, Y.K.; Katsaros, C.

    2013-01-01

    INTRODUCTION: Our objective was to investigate potential associations between maxillary sinus floor extension and inclination of maxillary second premolars and second molars in patients with Class II Division 1 malocclusion whose orthodontic treatment included maxillary first molar extractions.

  19. Feasibility of Shape-Memory Ni/Ti Alloy Wire Containing Tube Elevators for Transcrestal Detaching Maxillary Sinus Mucosa: Ex Vivo Study

    Directory of Open Access Journals (Sweden)

    Yanfeng Li

    2016-12-01

    Full Text Available Background: Osteotome sinus floor elevation is a less invasive approach to augment an insufficient alveolar bone at the posterior maxilla for dental implantation. However, this approach has some limitations due to the lack of sinus lift tools available for clinical use and the small transcrestal access to the maxillary sinus floor. We recently invented shape-memory Ni/Ti alloy wire containing tube elevators for transcrestal detaching maxillary sinus mucosa, and developed goat ex vivo models for direct visualizing the effectiveness of detaching sinus mucosa in real time during transcrestal maxillary sinus floor elevation. Methods: We evaluated our invented elevators, namely elevator 012 and elevator 014, for their effectiveness for transcrestal detaching maxillary sinus mucosa using the goat ex vivo models. We measured the length of sinus mucosa detached in mesial and distal directions or buccal and palatal directions, and the space volume created by detaching maxillary sinus mucosa in mesial, distal, buccal and palatal directions using the invented elevators. Results: Elevator 012 had a shape-memory Ni/Ti alloy wire with a diameter of 0.012 inch, while elevator 014 had its shape-memory Ni/Ti alloy wire with a diameter of 0.014 inch. Elevator 012 could detach the goat maxillary sinus mucosa in the mesial or distal direction for 12.1±4.3 mm, while in the buccal or palatal direction for 12.5±6.7 mm. The elevator 014 could detach the goat maxillary sinus mucosa for 23.0±4.9 mm in the mesial or distal direction, and for 19.0±8.1 mm in the buccal or palatal direction. An average space volume of 1.7936±0.2079 ml was created after detaching the goat maxillay sinus mucosa in both mesial/distal direction and buccal/palatal direction using elevator 012; while the average space volume created using elevator 014 was 1.8764±0.2366 ml. Conclusion: Both two newly invented tube elevators could effectively detach the maxillary sinus mucosa on the goat ex

  20. Feasibility of Shape-Memory Ni/Ti Alloy Wire Containing Tube Elevators for Transcrestal Detaching Maxillary Sinus Mucosa: Ex Vivo Study.

    Science.gov (United States)

    Li, Yanfeng; Wang, Fuli; Hu, Pin; Fan, Jiadong; Han, Yishi; Liu, Bin; Liu, Tao; Yang, Chunhao; Gu, Xiangmin

    2016-01-01

    Osteotome sinus floor elevation is a less invasive approach to augment an insufficient alveolar bone at the posterior maxilla for dental implantation. However, this approach has some limitations due to the lack of sinus lift tools available for clinical use and the small transcrestal access to the maxillary sinus floor. We recently invented shape-memory Ni/Ti alloy wire containing tube elevators for transcrestal detaching maxillary sinus mucosa, and developed goat ex vivo models for direct visualizing the effectiveness of detaching sinus mucosa in real time during transcrestal maxillary sinus floor elevation. We evaluated our invented elevators, namely elevator 012 and elevator 014, for their effectiveness for transcrestal detaching maxillary sinus mucosa using the goat ex vivo models. We measured the length of sinus mucosa detached in mesial and distal directions or buccal and palatal directions, and the space volume created by detaching maxillary sinus mucosa in mesial, distal, buccal and palatal directions using the invented elevators. Elevator 012 had a shape-memory Ni/Ti alloy wire with a diameter of 0.012 inch, while elevator 014 had its shape-memory Ni/Ti alloy wire with a diameter of 0.014 inch. Elevator 012 could detach the goat maxillary sinus mucosa in the mesial or distal direction for 12.1±4.3 mm, while in the buccal or palatal direction for 12.5±6.7 mm. The elevator 014 could detach the goat maxillary sinus mucosa for 23.0±4.9 mm in the mesial or distal direction, and for 19.0±8.1 mm in the buccal or palatal direction. An average space volume of 1.7936±0.2079 ml was created after detaching the goat maxillay sinus mucosa in both mesial/distal direction and buccal/palatal direction using elevator 012; while the average space volume created using elevator 014 was 1.8764±0.2366 ml. Both two newly invented tube elevators could effectively detach the maxillary sinus mucosa on the goat ex vivo sinus models. Moreover, elevator 014 has advantages over

  1. Comparison of short-term effects between face mask and skeletal anchorage therapy with intermaxillary elastics in patients with maxillary retrognathia.

    Science.gov (United States)

    Ağlarcı, Cahide; Esenlik, Elçin; Fındık, Yavuz

    2016-06-01

    The aim of this study was to compare the short-term dental and skeletal effects of a face mask (FM) with those of skeletal anchorage (SA) therapy with intermaxillary elastics in prepubertal patients with skeletal Class III malocclusion. Fifty patients with skeletal Class III malocclusion and maxillary deficiency were divided into two groups. In the FM group, an FM was applied by a bite plate with a force of 400g for each side. In the SA group, mini-plates were placed between mandibular lateral incisors and canines, and mini-implants were inserted between maxillary second premolars and first molars. A bite plate was inserted into the upper arch, and Class III elastics were applied with a force of 200g between each mini-plate and mini-implant. Mean treatment durations were 0.52±0.09 years for FM and 0.76±0.09 years for SA. After the treatment, statistically significant increases in SNA°, ANB°, A-y, 1-NA, SnGoGn°, Co-A, Co-Gn, and A-Nperp, and reductions in SNB° and FH┴N-Pg were observed in both groups, and these changes were similar in both groups. In the FM group, 1-NB decreased significantly, and in the SA group, it increased significantly (P journals.permissions@oup.com.

  2. A combined prosthodontic and orthodontic treatment approach in a case of growth inhibition induced by dental implants: a case report.

    Science.gov (United States)

    Krieger, Elena; Wegener, Joachim; Wagner, Wilfried; Hornikel, Sandra; Wehrbein, Heinrich

    2012-01-01

    Functional and esthetic results can improve significantly when a combined prosthodontic-orthodontic treatment approach is employed in cases requiring extensive oral rehabilitation. The patient presented in this case report was treated in his late teens with dental implants as a replacement for his maxillary incisors. Ten years later, the entire maxillary anterior segment was in infraocclusion compared to the rest of the dentition and lip line. Since prosthodontic follow-up treatment alone could not achieve an optimal functional and esthetic outcome, the patient was treated orthodontically prior to renewing the restoration. A fixed appliance was used to intrude the mandibular anterior teeth as well as vertically align the infrapositioned maxillary lateral incisors.

  3. Maxillary Bone Regeneration Based on Nanoreservoirs Functionalized ε-Polycaprolactone Biomembranes in a Mouse Model of Jaw Bone Lesion

    Directory of Open Access Journals (Sweden)

    Marion Strub

    2018-01-01

    Full Text Available Current approaches of regenerative therapies constitute strategies for bone tissue reparation and engineering, especially in the context of genetical diseases with skeletal defects. Bone regeneration using electrospun nanofibers’ implant has the following objectives: bone neoformation induction with rapid healing, reduced postoperative complications, and improvement of bone tissue quality. In vivo implantation of polycaprolactone (PCL biomembrane functionalized with BMP-2/Ibuprofen in mouse maxillary defects was followed by bone neoformation kinetics evaluation using microcomputed tomography. Wild-Type (WT and Tabby (Ta mice were used to compare effects on a normal phenotype and on a mutant model of ectodermal dysplasia (ED. After 21 days, no effect on bone neoformation was observed in Ta treated lesion (4% neoformation compared to 13% in the control lesion. Between the 21st and the 30th days, the use of biomembrane functionalized with BMP-2/Ibuprofen in maxillary bone lesions allowed a significant increase in bone neoformation peaks (resp., +8% in mutant Ta and +13% in WT. Histological analyses revealed a neoformed bone with regular trabecular structure, areas of mineralized bone inside the membrane, and an improved neovascularization in the treated lesion with bifunctionalized membrane. In conclusion, PCL functionalized biomembrane promoted bone neoformation, this effect being modulated by the Ta bone phenotype responsible for an alteration of bone response.

  4. [Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].

    Science.gov (United States)

    Azevedo, Cesar R de Farias; Hippert, Eduardo

    2002-01-01

    This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

  5. Determination of appropriate exposure angles for the reverse water's view using a head phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Su; Lee, Keun Ohk [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Choi, Jae Ho [Dept. of Radiological Technology, Ansan University, Ansan (Korea, Republic of); Jung, Jae Hong [Dept. of Biomedical Engineering, College of Medicine, The Catholic University, Seoul (Korea, Republic of)

    2017-06-15

    Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of 0 degree to 50 degrees, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus (36 degrees – 44 degrees), zygomatic arch (33 degrees – 40 degrees), petrous ridge (32 degrees – 50 degrees), and image distortion (44 degrees– 50 degrees). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from 36 degrees to 40 degrees in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

  6. Determination of appropriate exposure angles for the reverse water's view using a head phantom

    International Nuclear Information System (INIS)

    Lee, Min Su; Lee, Keun Ohk; Choi, Jae Ho; Jung, Jae Hong

    2017-01-01

    Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of 0 degree to 50 degrees, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus (36 degrees – 44 degrees), zygomatic arch (33 degrees – 40 degrees), petrous ridge (32 degrees – 50 degrees), and image distortion (44 degrees– 50 degrees). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from 36 degrees to 40 degrees in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography

  7. The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study.

    Science.gov (United States)

    Rocci, A; Calcaterra, R; DI Girolamo, M; Rocci, M; Rocci, C; Baggi, L

    2015-01-01

    Many factors could affect the osseous healing of implants such as surface topography of biomaterial, the status of the bone/implant site, implant loading conditions, surgical technique and implant design. The aim of this study was to analyze the BIC of 2 different implants systems characterized by different micro and macrogeometry, that were placed in the posterior maxillary and mandibular jaws of humans, clinically unloaded and retrieved for histomorphometric analyses after 12 weeks. The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. Osseointegration process was evaluated throughout measurements of BIC. No statistical significance differences were found among the mean percentage of BIC of Group I - type A were 66,51% versus 49,96% in Group I - type B, as well as among the mean percentage of BIC of Group II - type A were 43.7% versus 60.02% in Group II - type B. Our results highlight that the mean percentage of BIC after 12 weeks from the implants placement without functional loading is not influenced by the composition of the implant surface.

  8. Comparison of maxillary stability after Le Fort I osteotomy for occlusal cant correction surgery and maxillary advanced surgery.

    Science.gov (United States)

    Ueki, Koichiro; Hashiba, Yukari; Marukawa, Kohei; Yoshida, Kan; Shimizu, Chika; Nakagawa, Kiyomasa; Yamamoto, Etsuhide

    2007-07-01

    To compare postoperative maxillary stability following Le Fort I osteotomy for the correction of occlusal cant as compared with conventional Le Fort I osteotomy for maxillary advancement. The subjects were 40 Japanese adults with jaw deformities. Of these, 20 underwent a Le Fort I osteotomy and intraoral vertical ramus osteotomy (IVRO) to correct asymmetric skeletal morphology and inclined occlusal cant. The other 20 patients underwent a Le Fort I osteotomy and sagittal split ramus osteotomy (SSRO) to advance the maxilla. Lateral and posteroanterior cephalograms were taken postoperatively and assessed statistically. Thereafter, the 2 groups were followed for time-course changes. There was no significant difference between the 2 groups with regard to time-course changes during the immediate postoperative period. This suggests that maxillary stability after Le Fort I osteotomy for cant correction does not differ from that after Le Fort I osteotomy for maxillary advancement.

  9. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator.

    Science.gov (United States)

    Michelinakis, George

    2017-01-01

    This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  10. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator

    Directory of Open Access Journals (Sweden)

    George Michelinakis

    2017-01-01

    Full Text Available This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  11. Maxillary palp glomeruli and ipsilateral projections in the antennal ...

    Indian Academy of Sciences (India)

    Maxillary palp glomeruli and ipsilateral projections in the antennal lobe of Drosophila melanogaster. K P Rajashekhar V R ... The number of glomeruli receiving the maxillary palp sensory projections tallies with the number of Drosophila olfactory receptors (seven) reported to be expressed exclusively in the maxillary palp.

  12. Replacement of missing tooth in esthetic zone with implant-supported fixed prosthesis

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available In the anterior region, the common reason for tooth loss is due to traumatic injury or congenital anomaly. Loss of a single tooth may cause functional and esthetic deficits to the patient. There are different treatment options available for replacing a missing incisor. Implant dentistry should be considered as first treatment alternative for replace a missing tooth. This case report presents the replacement of a missing maxillary left central incisor in a compromised site with dental implants along with bone graft followed by frenectomy to obtain a good clinical result and for better function and esthetics of the patient.

  13. [Percutaneous maxillary nerve block anesthesia in maxillofacial surgery].

    Science.gov (United States)

    Robiony, M; Demitri, V; Costa, F; Politi, M

    1999-01-01

    Personal experience in percutaneous maxillary nerve block anesthesia in association with transmucosal anesthesia of the sphenopalatine ganglion in oral and maxillofacial surgery, is presented. Six Caldwell-Luc, 9 anthrotomies and biopsies of maxillary sinus, 8 removals of extensive odontogenic cysts and 12 surgical maxillary expansions were performed from 1994 to 1996 at our Department. Maxillary transcutaneous nerve block in association with transmucosal anesthesia of the sphenopalatine ganglion were performed. Carbocaine without adrenaline in association with NaCO3 1/10 for maxillary nerve block anesthesia and lidocaineoprilocaine cream (EMLA) for transmucosal anesthesia were employed. Intra- and post-operative pain were evaluated by visual analogue scale in all the patients. Anesthesiological procedures revealed to be effective in all surgical interventions and postoperative analgesia allowed easier pain control. The simplicity of execution, the effective pre- and postoperative anesthesia and the absence of side effects make this procedure particularly indicated in oral and maxillofacial surgery.

  14. Graft shrinkage and survival rate of implants after sinus floor elevation using a nanocrystalline hydroxyapatite embedded in silica gel matrix: a 1-year prospective study.

    Science.gov (United States)

    El Hage, Marc; Abi Najm, Semaan; Bischof, Mvark; Nedir, Rabah; Carrel, Jean-Pierre; Bernard, Jean-Pierre

    2012-06-01

    The aims of this study were (1) to evaluate the vertical shrinkage percentage of nanocrystalline hydroxyapatite embedded in silica gel used for maxillary sinus floor elevation (SFE) and (2) to determine the survival rate of the implants 1 year after placement in the healed grafted sinuses. Eleven maxillary sinuses were augmented in eight patients with NanoBone. After a healing period averaging 14.42 months, 19 implants were placed and followed up with clinical and radiographic evaluation. Panoramic radiographs were taken immediately after SFE and at 12 months after grafting. Measurements of changes in height were made by a computerized measuring technique using an image editing software. The mean graft height shrinkage percentage at 12 months after surgery was 8.84% (±5.32). One implant was lost before loading. All the 18 remaining osseointegrated implants received the prosthetic rehabilitation and were controlled after 3 months of functional loading. The implant survival rate at the 1-year interval was 94.74%. A 100% NanoBone alloplastic graft used in lateral SFE procedures presented limited height shrinkage. Implants placed in these grafted sinuses showed survival rates similar to those found in published data. These results should be interpreted cautiously considering the study's reduced sample size.

  15. Root Length and Anatomy of Impacted Maxillary Canines in Patients with Unilateral Maxillary Canine Impaction

    OpenAIRE

    Mostfa Shahabi; Maryam Omidkhoda; Seyedeh Haniyeh Omidi; Seyed Hosein Hoseini Zarch

    2017-01-01

    Introduction: Canine impaction is a common occurrence. In this study, we sought to investigate the root anatomy and length of impacted canines and lateral incisor adjacent to impacted maxillary canine. Materials and Methods: In this retrospective study, three-dimensional tomographic imaging was performed on 26 patients with unilateral maxillary canine impaction. In this study, we evaluated root length and anatomy of impacted canines, in terms of resorption intensity and curvature, with Planme...

  16. Perawatan Maloklusi Angle Kelas I disertai Impaksi Kaninus Maksila Menggunakan Alat Cekat Begg

    Directory of Open Access Journals (Sweden)

    Darmayanti Dian Suryani

    2014-12-01

     to hereditary factors. Prevalence of maxillary canines impaction is 0.9 to 2.2%, while the mandibular canine impaction is less common. Alternative dental care is impacted maxillary canine exposure surgery and followed by orthodontic force for help the eruption with fixed orthodontic appliance. The goal of treatment is to correct malrelation and malposition of teeth. Patient man, 19 years old, very crowded teeth, maxillary right and left canine and mandibular right canine impaction, Angle Class I, deep overbite, 3 mm overjet and overbite 8,8 mm. Treatments performed using Begg fixed appliances without extraction. Exposure surgery is done under the right and left maxillary canine impaction followed orthodontic bracket bonding. Multiloop arch wire, bend and elastic anchorage intermaksiler class II used at the stage of leveling and unraveling. Within 14 months, overbite was corrected, maxillaryr right and left canine eruption, Angle Class I canine relationship, 3.00 mm overjet, 3,00 mm overbite. Current treatment is still ongoing at leveling and unraveling stage. Treatment angle malocclusion class I with maxillary canine impaction can be done by exposure surgery followed by Begg fixed appliances.

  17. Maxillary distraction complications in cleft patients.

    Science.gov (United States)

    Jeblaoui, Y; Morand, B; Brix, M; Lebeau, J; Bettega, G

    2010-06-01

    Cleft lip and palate (CLP) patients often present with a class III malocclusion in connection with a three dimensional maxillary hypoplasia. Twenty-five to 60% of these patients need maxillary advancement. Two solutions are possible: orthognathic surgery and maxillary distraction. The purpose of this study was to evaluate the complications of maxillary distraction in CLP patients. Data was collected from the records of patients treated in our surgery unit between 2000 and 2007. Among the eight patients (four male and four female), five presented with a bilateral CLP, two with a unilateral CLP, and one with a unilateral cleft lip associated to a soft palate cleft. The average age at surgery was 17 years. All underwent a Le Fort I osteotomy with a pterygomaxillary disjunction. An external distractor was used for the first two patients and an internal distractor for the six following patients. After a seven-day latency, activation was implemented at a rate of 1mm twice a day. The average period of consolidation was four months. Maxillary advancement ranged between 7 and 19mm, with an average of 12.6mm. The average follow-up was four years. Complications were noted in seven patients: one intra-operative hemorrhage, one avulsion of a tooth anchored at the pterygoid process during osteotomy, three cases of device dysfunction, two cases of significant pain during activation, one loosening of the orthodontic arch in an external system, two cases of labial ulceration, and one maxillary sinusitis due to migration of a wisdom tooth. Complications of maxillary distraction in CLP patients were very frequent. Most were related to the device and did not interfere with the final result. This must be taken into account when indicating distraction and choosing the device. Two types of complications can occur during distraction: those related to the osteotomy and those related to the device. The complications related to the osteotomy are linked to the cicatricial ground of previous

  18. [Maxillary distraction complications in cleft patients].

    Science.gov (United States)

    Jeblaoui, Y; Morand, B; Brix, M; Lebeau, J; Bettega, G

    2008-09-01

    Cleft lip and palate (CLP) patients often present with a class III malocclusion in connection with a three dimensional maxillary hypoplasia. Twenty-five to 60% of these patients require a maxillary advancement. Two solutions are possible: orthognathic surgery and maxillary distraction. The purpose of this study was to evaluate the complications of the maxillary distraction in CLP patients. Data was collected from the records of patients treated at our Surgery Unit between 2000 and 2007. Among the eight patients (four male and four female), five presented a bilateral CLP, two a unilateral CLP and one a unilateral cleft lip associated to a soft palate cleft. The average age at surgery was 17 years old. All had a Le Fort I osteotomy with a pterygomaxillary disjunction. The first two patients had external distractors and the six following internal ones. After a seven-day latency, activation was led to the rate of 1mm per day twice. The period of consolidation was four months on average. The maxillary advancement varied between 7 and 19 mm with an average of 12.6mm. The average follow-up was four years. We encountered difficulties and/or complications in seven patients: one intraoperatively haemorrhage, one avulsion of a tooth fixed at the pterygoid process during the osteotomy, three device failures, two cases of significant pains during activation, one dissociation of the dental anchorage of an external system, two labial ulcerations and one maxillary sinusitis by migration of the 18. Difficulties of maxillary distraction in CLP patients are very frequent. The majority is related to the distractors and did not interfere with the final result. But this frequency must be taken into account in the indication and in the choice of the material. Two types of complications can occur during distraction: those related to the osteotomy and those related to the material. The complications related to the osteotomy are in connection with the cicatricial ground of the CLP. They are

  19. Le Fort I Maxillary Advancement Using Distraction Osteogenesis

    OpenAIRE

    Combs, Patrick D.; Harshbarger, Raymond J.

    2014-01-01

    Treatment of maxillary hypoplasia has traditionally involved conventional Le Fort I osteotomies and advancement. Advancements of greater than 10 mm risk significant relapse. This risk is greater in the cleft lip and palate population, whose anatomy and soft tissue scarring from prior procedures contributes to instability of conventional maxillary advancement. Le Fort I advancement with distraction osteogenesis has emerged as viable, stable treatment modality correction of severe maxillary hyp...

  20. Prognostic trend in advanced implant surgery.

    Science.gov (United States)

    Demitri, V; Polini, F; Robiony, M; Politi, M

    2002-03-01

    Implant surgery in association with bone grafting is generally considered less predictive than primary implant surgery. Many reports have been published about implant rehabilitation with bone grafts in atrophic patients. Most of these papers showed a lower implant success rate than primary implantology. The aim of this study is to verify if it's possible to warrant similar results between the two types of implantology, if such procedures are performed following effective protocols and criteria. From 1995 to 1999, 43 severely atrophic edentulous patients were treated in our Clinic with 63 autologous bone grafts and delayed implantology; 45 patients were treated with traditional implantology. 284 fixtures were positioned. The success rate in grafted implantology versus traditional implantology was compared for every maxillary and mandibular region. Furthermore, success rate in implantology of the anterior maxilla versus the poster maxilla in grafted patients was compared. The statistical considerations were performed with c2 test (p<0.05). The statistical analysis evidenced not significative difference in the implant success rate between grafted and not grafted patients in the anterior (p=0.23) and in the posterior maxilla (p=0.35). There was not significative difference in the implant success rate between grafted and not grafted patients in the anterior mandible (p=0.54) and in the posterior mandible (p=0.54). There was not significative difference in the implant success rate between the anterior and posterior grafted maxilla (p=0.21). The results obtained show that if close surgical protocol is performed it is possible to obtain no prognostic difference between the two METHODS.

  1. 3D Metal Printing - Additive Manufacturing Technologies for Frameworks of Implant-Borne Fixed Dental Prosthesis.

    Science.gov (United States)

    Revilla León, M; Klemm, I M; García-Arranz, J; Özcan, M

    2017-09-01

    An edentulous patient was rehabilitated with maxillary metal-ceramic and mandibular metal-resin implant-supported fixed dental prosthesis (FDP). Metal frameworks of the FDPs were fabricated using 3D additive manufacturing technologies utilizing selective laser melting (SLM) and electron beam melting (EBM) processes. Both SLM and EBM technologies were employed in combination with computer numerical control (CNC) post-machining at the implant interface. This report highlights the technical and clinical protocol for fabrication of FDPs using SLM and EBM additive technologies. Copyright© 2017 Dennis Barber Ltd.

  2. Histomorhological and clinical evaluation of maxillary alveolar ridge reconstruction after craniofacial trauma by applying combination of allogeneic and autogenous bone graft.

    Science.gov (United States)

    De Ponte, Francesco Saverio; Falzea, Roberto; Runci, Michele; Siniscalchi, Enrico Nastro; Lauritano, Floriana; Bramanti, Ennio; Cervino, Gabriele; Cicciu, Marco

    2017-02-01

    A variety of techniques and materials for the rehabilitation and reconstruction of traumatized maxillary ridges prior to dental implants placement have been described in literature. Autogenous bone grafting is considered ideal by many researchers and it still remains the most predictable and documented method. The aim of this report is to underline the effectiveness of using allogeneic bone graft for managing maxillofacial trauma. A case of a 30-year-old male with severely atrophic maxillary ridge as a consequence of complex craniofacial injury is presented here. Augmentation procedure in two stages was performed using allogeneic and autogenous bone grafts in different areas of the osseous defect. Four months after grafting, during the implants placement surgery, samples of both sectors were withdrawn and submitted to histological evaluation. On the examination of the specimens, treated by hematoxylin and eosin staining, the morphology of integrated allogeneic bone grafts was revealed to be similar to the autologous bone. Our clinical experience shows how the allogeneic bone graft presented normal bone tissue architecture and is highly vascularized, and it can be used for reconstruction of severe trauma of the maxilla. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  3. Tooth-Borne Anterior Maxillary Distraction for Cleft Maxillary Hypoplasia: Our Experience With 147 Patients.

    Science.gov (United States)

    Richardson, Sunil; Selvaraj, Dhivakar; Khandeparker, Rakshit V; Seelan, Nikkie S; Richardson, Shweta

    2016-12-01

    To evaluate the results of anterior maxillary distraction for its efficacy and long-term stability in the management of cleft maxillary hypoplasia in a large series of patients with a long-term follow-up extending to 4 years. One hundred sixty-four patients at least 10 years old with cleft maxillary hypoplasia who presented to the authors' unit from January 2009 through October 2014 were evaluated retrospectively, irrespective of gender, type of cleft lip and palate, and amount of advancement needed. Anterior maxillary distraction using a tooth-borne distractor appliance was carried out in all patients and all patients were followed up to 4 years (range, 1 to 4 yr) to evaluate the stability of the procedure and to document any relapse using digitalized lateral cephalograms taken before distraction, immediately after distraction (T2), and at the last follow-up visit (T3; range, 1 to 4 yr). Seventeen patients were subsequently lost to follow-up; therefore, a complete set of records was available for 147 patients. In a subset of 50 patients, perceptual speech assessment was carried out preoperatively and 6 months postoperatively by 2 speech pathologists using the Perkins scoring system that allowed the evaluation of 5 parameters (velopharyngeal insufficiency, resonance, nasal air emission, articulation, and intelligibility). None of these patients underwent speech therapy during the course of evaluation. The development of complications intra- or postoperatively was noted. The data were tabulated and analyzed. An advancement ranging from 4.0 to 13.1 mm (mean, 9.42 mm) was achieved in all patients. One hundred forty patients (95.23%) showed stable results on lateral cephalograms and when T2 values were compared with T3 values. Seven patients (4.76%) exhibited skeletal relapse in various linear and angular measurements assessed on lateral cephalograms. At 6-month follow-up, improvements of 62% (n = 31), 64% (n = 32), 50% (n = 25), 68% (n = 34), and 70% (n

  4. Le Fort I Maxillary Advancement Using Distraction Osteogenesis

    Science.gov (United States)

    Combs, Patrick D.; Harshbarger, Raymond J.

    2014-01-01

    Treatment of maxillary hypoplasia has traditionally involved conventional Le Fort I osteotomies and advancement. Advancements of greater than 10 mm risk significant relapse. This risk is greater in the cleft lip and palate population, whose anatomy and soft tissue scarring from prior procedures contributes to instability of conventional maxillary advancement. Le Fort I advancement with distraction osteogenesis has emerged as viable, stable treatment modality correction of severe maxillary hypoplasia in cleft, syndromic, and noncleft patients. In this article, the authors provide a review of current data and recommendations concerning Le Fort I advancement with distraction osteogenesis. In addition, they outline their technique for treating severe maxillary hypoplasia with distraction osteogenesis using internal devices. PMID:25383054

  5. Simplified Model Surgery Technique for Segmental Maxillary Surgeries

    Directory of Open Access Journals (Sweden)

    Namit Nagar

    2011-01-01

    Full Text Available Model surgery is the dental cast version of cephalometric prediction of surgical results. Patients having vertical maxillary excess with prognathism invariably require Lefort I osteotomy with maxillary segmentation and maxillary first premolar extractions during surgery. Traditionally, model surgeries in these cases have been done by sawing the model through the first premolar interproximal area and removing that segment. This clinical innovation employed the use of X-ray film strips as separators in maxillary first premolar interproximal area. The method advocated is a time-saving procedure where no special clinical or laboratory tools, such as plaster saw (with accompanying plaster dust, were required and reusable separators were made from old and discarded X-ray films.

  6. Bilateral supernumerary primary maxillary canines

    Directory of Open Access Journals (Sweden)

    Santanu Mukhopadhyay

    2018-01-01

    Full Text Available Supernumerary teeth are more common in the permanent than in primary dentition. In the primary dentition, the anomaly is most frequently observed in the maxillary lateral incisor region, followed by the maxillary midline where they are termed as mesiodens. Supernumerary teeth in the primary canine region are rare. This paper describes a rare case of nonsyndromic supernumerary primary maxillary canine distributed bilaterally in a 4-year-old boy. Both the supernumeraries resembled size and shape of normal primary canine. The right supplemental canine is high labially placed, whereas the left one is seen normally aligned in the dental arch distal to lateral incisor. One of the most significant sequelae of primary supernumerary teeth is their duplication in the permanent series. Radiographic examination of supernumerary primary canine did not indicate any such anomaly in the permanent dentition. The patient was kept under observation.

  7. Natural reversal of tooth discoloration and pulpal response to testing following removal of a miniscrew implant for orthodontic anchorage: a case report.

    Science.gov (United States)

    Qin, Y J; Zhang, G D; Zhang, Y; Ping, Y F; Zhao, C Y

    2016-04-01

    To highlight the reversal of signs suggesting pulpal necrosis following removal of a mini-implant without endodontic intervention. A 23-year-old woman presented with a class III malocclusion, with crowded and malformed teeth and excessive gingival display. During orthodontic treatment, a Tomas orthodontic miniscrew was placed between the root apices of the maxillary central incisors. This was carried out by an orthodontic specialist who had treated more than 700 patients (with more than 2000 mini-implants) over the past 9 years. After 2 weeks of treatment, the right maxillary central incisor discoloured and did not respond to electrical pulp tests (EPT) but was sensitive to endo-ice. The miniscrew was removed under local anaesthesia. Teeth 11 and 21 were fixed with ligation wire, and glass-ionomer cement (GIC) was added to the occlusal surfaces of the first and second maxillary molars to heighten the occlusion and disclude the maxillary anterior teeth. After 4 months, the colour and pulp reactions to EPT and endo-ice of tooth 11 returned to normal. Because the use of a miniscrew had appeared to damage the pulp, subsequent a conservative orthodontic treatment using, traditional 'J' hooks was used and achieved satisfactory results. After 23 months of orthodontic treatment, the treatment was complete and a 15-month follow-up showed a successful outcome. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    Science.gov (United States)

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant

  9. Simultaneous malaroplasty with porous polyethylene implants and orthognathic surgery for correction of malar deficiency.

    Science.gov (United States)

    Robiony, M; Costa, F; Demitri, V; Politi, M

    1998-06-01

    Patients with skeletal malrelationships caused by maxillary anteroposterior defect and midface hypoplasia may present with an alteration of cheekbone contour. High osteotomies, segmental osteotomies of the zygomatic complex, and malar expansion with alloplastic materials can be performed to improve facial aesthetics. This article describes the restoration of cheekbone-nasal base-lip contour by performing a malaroplasty using an alloplastic implant in addition to orthognathic surgery. From 1995 to 1996, 17 patients with maxillomandibular malrelationships and deficient cheekbone contour were tested by malar augmentation with porous high-density polyethylene in association with maxillary advancement and mandibular setback. The diagnosis of cheekbone contour alteration was made after observing the patient from a lateral, frontal, and oblique point of view. The position of the implant was determined by using Mladick's point, with lateral or medial extension in relation to the depressed area. By the restoration of normal cheekbone-nasal base-upper lip contour produced excellent aesthetic results in all patients. Malaroplasty in association with bimaxillary orthognathic surgery seems to be an effective procedure for treating midface skeletal deficiencies.

  10. Soft Tissue Esthetics in Implant Dentistry

    Directory of Open Access Journals (Sweden)

    Rakesh V. Somanathan

    2007-01-01

    Full Text Available Dental implants have been considered to be a successful treatment modality. Recently, achieving a good osseointegration is not the ultimate goal for the restorative dentist. Successful implant treatment demands the best gingival esthetic success along with stability and function of the implant. This study was performed to obtain answers to some controversial points pertaining to esthetics and function of implants in maxilla. Immediate flapless implantation into the extraction sockets in maxillary anterior zone is an emerging treatment option in dentistry- the esthetic success of which was in debate for long. The proposed study compared the esthetic success of immediate flapless implants (ILA, to immediate implants with the need for flap (ILB and, delayed implants (DSL in single tooth restorations, in the anterior region of the maxilla. The other aim of the study was to find out if any relation exists between the interproximal crestal bone height and papilla height. Analysis was done irrespective of treatment procedure in the same study group using periodontal sounding and radiographs to find out the relation. From the study involving 106 participants, including 21 ILA, 22 ILB and 63 DSL cases, we received highest papillary index score of 2.6 average from group ILA, followed by ILB and DSL, after 3 months of prosthetic loading. From the periodontal sounding and radiographic study it was evident that, when the distance between the base of the contact point of crowns and height of interproximal bone was less than 5, the papilla was present 100 % of the time, but when the distance increased to 6 and more than 7 mm, the papilla was present only 46.5 and 24 percentage of the time respectively.

  11. Autogenous transplantation of maxillary and mandibular molars.

    Science.gov (United States)

    Reich, Peter P

    2008-11-01

    Autogenous tooth transplantation has been used as a predictable surgical approach to correct malocclusion and replace edentulous areas. This article focuses on the surgical approach and technique for molar transplantation. Thirty-two patients aged between 11 and 25 years underwent 44 autogenous molar transplantations. The procedure involved transplantation of impacted or newly erupted third molars into the extraction sockets of nonrestorable molars and surgical removal and replacement of horizontally impacted molars into their proper vertical alignment. Five basic procedural concepts were applied: 1) atraumatic extraction, avoiding disruption of the root sheath and root buds; 2) apical contouring of bone at the transplantation site and maxillary sinus lift via the Summers osteotome technique, when indicated, for maxillary molars; 3) preparation of a 4-wall bony socket; 4) avoidance of premature occlusal interferences; and 5) stabilization of the tooth with placement of a basket suture. All 32 patients successfully underwent the planned procedure. To date, 2 patients have had localized infection that resulted in loss of the transplant. The remaining 42 transplants remain asymptomatic and functioning, with a mean follow-up period of 19 months. No infection, ankylosis, loss of the transplant, or root resorption has been noted. In addition, endodontic therapy has not been necessary on any transplanted teeth. Autogenous tooth transplantation has been discussed and described in the literature previously, with a primary focus on cuspid and bicuspid transplantation. The molar transplant is infrequently discussed in today's literature, possibly because of the preponderance of titanium dental implants. Autogenous molar transplantation is a viable procedure with low morbidity and excellent functional and esthetic outcomes. This report shows the successful transplantation of 42 of 44 molars in 32 patients with a mean follow-up period of 19 months.

  12. Maxillary sinus floor augmentation with Bio-Oss or Bio-Oss mixed with autogenous bone as graft in animals

    DEFF Research Database (Denmark)

    Jensen, T; Schou, S; Stavropoulos, Andreas

    2012-01-01

    The objective of the present systematic review was to test the hypothesis of no differences between the use of Bio-Oss or Bio-Oss mixed with autogenous bone as graft for maxillary sinus floor augmentation (MSFA) applying the lateral window technique, as evaluated in animals. A MEDLINE (Pub...... of the graft improved significantly with increased proportion of Bio-Oss. Bone regeneration, bone-to-implant contact (BIC), biomechanical implant test values, and biodegradation of Bio-Oss after MSFA with Bio-Oss or Bio-Oss mixed with autogenous bone have never been compared within the same study in animals....... Thus, the hypothesis of no differences between the use of Bio-Oss and Bio-Oss mixed with autogenous bone as graft for MSFA could neither be confirmed nor rejected based on existing animal studies....

  13. Strategic camouflage treatment of skeletal Class III malocclusion (mandibular prognathism) using bone-borne rapid maxillary expansion and mandibular anterior subapical osteotomy.

    Science.gov (United States)

    Seo, Yu-Jin; Lin, Lu; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2016-01-01

    This case report presents the camouflage treatment that successfully improved the facial profile of a patient with a skeletal Class III malocclusion using bone-borne rapid maxillary expansion and mandibular anterior subapical osteotomy. The patient was an 18-year-old woman with chief complaints of crooked teeth and a protruded jaw. Camouflage treatment was chosen because she rejected orthognathic surgery under general anesthesia. A hybrid type of bone-borne rapid maxillary expander with palatal mini-implants was used to correct the transverse discrepancy, and a mandibular anterior subapical osteotomy was conducted to achieve proper overjet with normal incisal inclination and to improve her lip and chin profile. As a result, a Class I occlusion with a favorable inclination of the anterior teeth and a good esthetic profile was achieved with no adverse effects. Therefore, the hybrid type of bone-borne rapid maxillary expander and a mandibular anterior subapical osteotomy can be considered effective camouflage treatment of a skeletal Class III malocclusion, providing improved inclination of the dentition and lip profile. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Immediate Implant Placement and Provisionalization Using the Patient's Extracted Crown: 12-Month Follow-Up.

    Science.gov (United States)

    Deliberador, Tatiana Miranda; Begnini, Gilmar José; Tomazinho, Flávia; Rezende, Carlos Eduardo Edwards; Florez, Fernando Luis Esteban; Leonardi, Denise Piotto

    2018-03-01

    Immediate placement and provisionalization of implants in fresh sockets has been previously demonstrated to be a predictable treatment in the restoration of non-recoverable teeth in the anterior regions of the maxilla. This article reports a clinical case in which an immediate implant placement protocol was used in combination with two distinct and sequential grafts (bovine bone and connective tissue, respectively) followed by immediate implant provisionalization using the patient's crown of an extracted tooth. Physical, clinical, and image examinations of the patient (female, 23 years old) revealed a maxillary central incisor (tooth No. 8) with slight mobility due the presence of extensive cervical resorption. The treatment proposed was the atraumatic extraction of the tooth followed by immediate implant placement and provisionalization. Two grafts (bovine bone and connective tissue) were used due to the presence of a very thin maxillary bone plate associated with a thin gingival biotype. The use of the extracted crown as a temporary crown after immediate implant placement resulted in immediate attainment of an esthetically pleasing outcome and long-term favorable results. The treatment protocol proposed can be efficiently used to immediately restore the patient's esthetics and function while maintaining the health, volume, and contours of gingival tissues over a 12-month follow-up period. Anterior teeth extractions typically require the execution of single-unit prostheses using dental materials of synthetic origin (such as polymers), which often are incapable of achieving the esthetic and physiological results patients expect. The use of the patient's own crown was demonstrated, which allowed good clinical results to be achieved and the natural shape and function of tissues to be maintained.

  15. Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.

  16. Carprofen neither reduces postoperative facial expression scores in rabbits treated with buprenorphine nor alters long term bone formation after maxillary sinus grafting.

    Science.gov (United States)

    Hedenqvist, Patricia; Trbakovic, Amela; Thor, Andreas; Ley, Cecilia; Ekman, Stina; Jensen-Waern, Marianne

    2016-08-01

    In connection with bilateral maxillary sinus augmentation, the acute effects of the nonsteroidal anti-inflammatory drug carprofen on facial expressions and long-term effects on bone formation were evaluated in 18 male New Zealand White rabbits. A 10×10mm bone window was drilled in the maxilla, the sinus membrane elevated and a titanium mini-implant inserted. One of two test materials was randomly inserted unilaterally and bovine bone chips (control) on the contralateral side in the created space. Rabbits were randomly allocated to receive buprenorphine plus carprofen (n=9) or buprenorphine plus saline (n=9) postoperatively. Buprenorphine was administered subcutaneously every 6h for 3days in a tapered dose (0.05-0.01mg/kg) and carprofen (5mg/kg) or saline administered subcutaneously 1h before, and daily for 4days postoperatively. To assess pain, clinical examination, body weight recording and scoring of facial expressions from photos taken before, and 6-13h after surgery were performed. Twelve weeks after surgery the rabbits were euthanized and sections of maxillary bones and sinuses were analysed with histomorphometry and by qualitative histology. Carprofen had no effect on mean facial expression scores, which increased from 0.0 to 3.6 (carprofen) and 4.3 (saline), of a maximum of 8.0. Neither did carprofen have an effect on bone formation or implant incorporation, whereas the test materials had. In conclusion, treatment with 5mg/kg carprofen once daily for 5days did not reduce facial expression scores after maxillary sinus augmentation in buprenorphine treated rabbits and did not affect long term bone formation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Odontogenic maxillary sinusitis diagnosed using conebeam x-ray CT

    International Nuclear Information System (INIS)

    Sato, Kiminori

    2007-01-01

    We evaluated the usefulness of conebeam x-ray CT in the diagnosis of odontogenic maxillary sinusitis in 21 patients. Among teeth causing odontogenic maxillary sinusitis, 95% had apical lesions after root canal treatment. Most root canals were filled with filling materials incompletely. Apical lesions in inappropriately treated teeth thus caused odontogenic maxillary sinusitis. Conebeam CT involves 3-dimensional isotropic voxel image date in up to 512 frames for transaxial, coronal, and sagittal planes, so resolution in imaging on the body axis was especially high. Multiplanar reconstruction and volume rendering images at any optional plane could be obtained without interpolation. The relationship between causative teeth and the maxillary sinus could be observed and measured, and odontogenic maxillary sinusitis accurately diagnosed. In addition to the accurate diagnosis of apical lesions, maxilla, and maxillary sinus, periodontal ligament space, lamina dura, pulp cavity, root canal, canal-treated root, apical periodontitis, alveolar ostitis, marginal periodontitis of causative teeth could be observed. Metal artifacts were minimized, making conebeam CT useful in the diagnosis of periodontal tissue and causative teeth, including root-canal-treated and crown-restored teeth. (author)

  18. Wettability control of polystyrene by ion implantation

    International Nuclear Information System (INIS)

    Suzuki, Yoshiaki; Kusakabe, Masahiro; Iwaki, Masaya

    1994-01-01

    The permanent effects of ion implantation on the improvement of wettability of polystyrene is investigated in relation to ion species and fluences. The He + , Ne + , Na + , N 2 + , O 2 + , Ar + , K + and Kr + ion implantations were performed at energies of 50 and 150 keV at room temperature. The fluences ranged from 1x10 15 to 1x10 17 ions/cm 2 . The results showed that the contact angle of water for Na + and K + implanted polystyrene decreased from 87 to 0 , as the fluences increased to 1x10 17 ions/cm 2 at an energy of 50 keV. The contact angle for Na + and K + implanted polystyrene did not change under ambient room conditions, even when time elapsed. However, the contact an gle for He + , C + , O + , Ne + , N 2 + , O 2 + , Ar + , and Kr + ion implanted specimens decreased slightly immediately after ion implantation. Results of X-ray photoelectron spectroscopy showed that the increase in the Na content in the surface of Na + implanted specimens were observed with increasing fluence. It is concluded that permanent improvement in wettability was caused by doping effects rather than by radiation effects from Na + and K + ion implantation. ((orig.))

  19. Long-Term Skeletal Changes After Maxillary Distraction Osteogenesis in Growing Children With Cleft Lip/Palate.

    Science.gov (United States)

    Liu, Kai; Zhou, Nuo

    2018-02-14

    To systematically evaluate the skeletal changes after maxillary distraction osteogenesis (DO) in growing patients with cleft lip with or without cleft palate (CL/P). Electronic databases, gray literature, and reference list searches were conducted. Articles reporting prospective and retrospective studies that included patients 1 year were reviewed. The original articles were evaluated by 2 investigators to ensure that they met the selection criteria. A methodologic quality assessment tool was used to evaluate the quality of selected studies. Twenty-six studies met the initial search criteria, and 9 articles included 101 growing patients with maxillary hypoplasia due to CL/P who received DO surgery were finally selected and analyzed. The results showed that long term after maxillary advancement with DO, the horizontal relapse in A-point was 40% in 1 study. Totally, the range of horizontal relapse in A-point was 11.9% to 45.9%. Similarly, the relapse in SNA angle was 40% in 2 studies. Totally, the range of relapse in SNA was 25.7% to 77%. Two studies showed that the vertical relapse in A-point were 137% and 208%, and in the PNS point were 65% and 62.7%. Although findings demonstrated that DO is an effective treatment method for severe maxillary hypoplasia in growing patients with CL/P, there is a relatively high amount of skeletal relapse both in horizontal and vertical dimension. Thus, the first proposed alternative for CL/P patients would be to select the correct primary procedure to decrease damage and avoid unnecessary scars. Then appropriate preoperative and postoperative care is necessary to prevent postoperative relapse. In addition, overcorrection also may be a possible alternative for compensation of postoperative relapse.

  20. The efficacy of short (6 mm) dental implants with a novel thread design.

    Science.gov (United States)

    Bechara, Soheil; Nimčenko, Tatjana; Kubilius, Ričardas

    2017-01-01

    To assess efficacy of short (6 mm) implants with a novel macrostructure and thread design placed in a compromised bone situations of edentulous posterior regions of maxilla (3-4 mm of bone height under sinus floor) as compared to results of clinical situations treated with simultaneous maxillary sinus grafting and placement of long (≥10 mm) implants of the same company. Clinical cases of conducted clinical study. Patients with compromised bone height in edentulous posterior regions of maxilla were randomly divided into two groups. Short (6mm length) implant treatment conducted in the test group and simultaneous sinus lift with standard length implant placement treatment in the control group. In general implant stability quotient (ISQ) and marginal bone level (MBL) changes values in both groups were comparable. However, significant negative correlation was found between implant's diameter and MBL changes. Implant's length has little if none impact on initial implant anchorage, especially in greatly compromised residual bone situations. Results have confirmed that implant initial stability mainly depends on implant's macro-design and further its development on implant's micro-design: namely, implant diameter rather than length, tapered shape and improved thread design determines primarily acquired mechanical anchorage, while bioactive surface treatment ensures development of biological stability.

  1. Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Paul A. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States)]. E-mail: pclark4@gmail.com; Clark, Andrew M. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Rodriguez, Anthony [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Hussain, Mohammad A. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Mao, Jeremy J. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States)]. E-mail: jmao2@uic.edu

    2007-04-15

    Bone-implant interface is characterized by an array of cells and macromolecules. This study investigated the nanomechancial properties of bone-implant interface using atomic force microscopy in vitro, and the mechanical modulation of implant bone ingrowth in vivo using bone histomorphometry. Upon harvest of screw-type titanium implants placed in vivo in the rabbit maxilla and proximal femur for 4 weeks, nanoindentation was performed in the bone-implant interface at 60-{mu}m intervals radially from the implant surface. The average Young's Moduli (E) of the maxillary bone-implant interface was 1.13 {+-} 0.27 MPa, lacking significant differences at all intervals. In contrast, an increasing gradient of E was observed radially from the femur bone-implant interface: 0.87 {+-} 0.25 MPa to 2.24 {+-} 0.69 MPa, representing significant differences among several 60-{mu}m intervals. In a separate experiment, bone healing was allowed for 6 weeks for proximal femur implants. The right femoral implant received axial cyclic loading at 200 mN and 1 Hz for 10 min/d over 12 days, whereas the left femoral implant served as control. Cyclic loading induced significantly higher bone volume, osteoblast numbers per endocortical bone surface, mineral apposition rate, and bone formation rate than controls. These data demonstrate nanoscale and microscale characterizations of bone-implant interface, and mechanical modulation of bone ingrowth surrounding titanium implants.

  2. Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth

    International Nuclear Information System (INIS)

    Clark, Paul A.; Clark, Andrew M.; Rodriguez, Anthony; Hussain, Mohammad A.; Mao, Jeremy J.

    2007-01-01

    Bone-implant interface is characterized by an array of cells and macromolecules. This study investigated the nanomechancial properties of bone-implant interface using atomic force microscopy in vitro, and the mechanical modulation of implant bone ingrowth in vivo using bone histomorphometry. Upon harvest of screw-type titanium implants placed in vivo in the rabbit maxilla and proximal femur for 4 weeks, nanoindentation was performed in the bone-implant interface at 60-μm intervals radially from the implant surface. The average Young's Moduli (E) of the maxillary bone-implant interface was 1.13 ± 0.27 MPa, lacking significant differences at all intervals. In contrast, an increasing gradient of E was observed radially from the femur bone-implant interface: 0.87 ± 0.25 MPa to 2.24 ± 0.69 MPa, representing significant differences among several 60-μm intervals. In a separate experiment, bone healing was allowed for 6 weeks for proximal femur implants. The right femoral implant received axial cyclic loading at 200 mN and 1 Hz for 10 min/d over 12 days, whereas the left femoral implant served as control. Cyclic loading induced significantly higher bone volume, osteoblast numbers per endocortical bone surface, mineral apposition rate, and bone formation rate than controls. These data demonstrate nanoscale and microscale characterizations of bone-implant interface, and mechanical modulation of bone ingrowth surrounding titanium implants

  3. Immediate implant placement and restoration in the anterior maxilla: Tissue dimensional changes after 2-5 year follow up.

    Science.gov (United States)

    Arora, Himanshu; Khzam, Nabil; Roberts, David; Bruce, William L; Ivanovski, Saso

    2017-08-01

    Immediate implant placement followed by an immediate restoration has proven to be a viable technique in the anterior maxillary region. This prospective study evaluated the mid-long term (2-5 years) tissue changes around immediately placed and restored implants in the anterior maxilla using flapless surgery and simultaneous hard tissue augmentation. Thirty AstraTech implants were immediately placed in 30 patients, followed by the delivery of an immediate provisional restoration on the same day. All participating 30 patients underwent the same treatment strategy that involved flapless removal of a failing maxillary anterior tooth, immediate implant placement, simultaneous augmentation with a deproteinized particulate xenograft, followed by the connection of a screw-retained provisional restoration. Radiographs and photographs were used to measure hard and soft tissue changes. Aesthetic evaluation was performed using the Pink Esthetic Score (PES). All implants remained osseointegrated during the follow up period of 2-5 years (mean 47 ± 15 months). Twelve of the thirty patients completed the 5 year follow up. Radiographic evaluation revealed average gains in bone levels of 0.18 and 0.34 mm mesially and distally, respectively. Soft tissue evaluation showed a mean tissue loss of 0.05 ± 0.64 mm and 0.16 ± 0.63 mm at the mesial and distal papillae, respectively, while mid-facial mucosal recession was 0.29 ± 0.74 mm. A significant improvement in the Pink Esthetic Scores was seen at the final follow-up (mean PES 11.50), as compared to the baseline (mean PES 10.27) (P = .001). In addition to a favorable implant success rate and peri-implant bony response, the soft tissue levels and overall aesthetics around single immediately placed and restored implants can also be maintained in the mid-long term. © 2017 Wiley Periodicals, Inc.

  4. Assessment of implant stability during various stages of healing placed immediately following extraction in an overdenture situation

    OpenAIRE

    Ashwin Thomas Koshy; T Aby Mathew; Nicholas Mathew; Angel Mary Joseph

    2017-01-01

    To assess the implant stability during different stages of healing in an immediate loaded implant soon after extraction. A 73-year-old female came with a chief complaint of bad smell and irritation in her lower front gum region. On examination, she was found to be completely edentulous in the maxillary arch and partially edentulous in the mandibular arch with only the canines present bilaterally. The posterior mandibular ridge was severely resorbed and hence could not be treated with a conven...

  5. Measurement of maxillary sinus volume using Computed Tomography

    International Nuclear Information System (INIS)

    Park, Chang Hee; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    To propose a standard value for the maxillary sinus volume of a normal Korean adult by measuring the width and height of the sinus and analyzing their correlation and the difference of the sinus size respectively between sexes, and on the right and left sides. Fifty-two (95 maxillary sinuses) out of 20 years or over aged patients who had taken CT in the Department of Dental Radiology, Yonsei University, Dental Hospital, between February 1997 and July 1999 who were no specific symptom, prominent bony septa, pathosis, clinical asymmetry and history of surgery in the maxillary sinus were retrospectively analyzed. The mean transverse width, antero-posterior width, height and volume of the normal Korean adult's maxillary sinuses were 28.33 mm, 39.69 mm, 46.60 mm and 21.90 cm 3 , respectively. There was a significant sex difference in the sinus volume (p<0.05). In the mean antero-posterior width, height and volume of the sinus, no significant difference was observed between both sides. All four measurements showed a significant correlation between both sides (p<0.0001). The widths and height of the sinus all showed a significant correlation with the sinus volume (p<0.0001). In the Korean normal adult's maxillary sinus, males tended to be larger than females. Except for the transverse width, all of the measurements showed no significant difference between the right and left side, but significant correlations in the four measurements between both sides were observed. Thus, the overgrowth or undergrowth in the unilateral maxillary sinus may suggest a certain pathosis or developmental abnormalities in the maxillary sinus.

  6. Management of an Unusual Ectopic Eruption of Maxillary Canine.

    Science.gov (United States)

    Aileni, Kaladhar Reddy; Rachala, Madhukar Reddy; Prathima, Chintakunta Reddy; Naveen, Pitalla Kumar; Soujanya, Donthula

    2017-05-01

    Transposition of teeth is a rare condition, with a prevalence of 0.3-0.4% in general population. They are more commonly observed in females, and may occur unilaterally/bilaterally with greater frequency of left side occurrence in unilateral transposition cases. A 17-year-old female patient reported with the chief complaint of unaesthetic smile. On clinical examination the patient was diagnosed with Angle's class I malocclusion with an ectopically erupted maxillary left canine labial to the left central incisor with retained deciduous canine. The treatment plan decided was to extract the retained deciduous canine, level and align the ectopic canine using an R-loop. The treatment for the patient was finished in 14 months and was retained using a fixed lingual retainer in the upper and lower arches.

  7. Surgical-Orthodontic Treatment of Gummy Smile with Vertical Maxillary Excess

    Directory of Open Access Journals (Sweden)

    Sumit Kumar Yadav

    2014-01-01

    Full Text Available Vertical maxillary excess is a well-defined clinical entity with several treatment options available. Treatment of the condition requires extremely well-coordinated orthodontic and surgical treatment planning and execution. This case report describes a multidisciplinary approach in the successful management of a patient with severe vertical maxillary excess. Careful selection and good execution of a surgical-orthodontic treatment plan in the management of vertical maxillary excess provided the superior esthetic and functional results in this case. Maxillary Le Forte 1 procedure was performed for vertical maxillary impaction along with anterior segmental setback. The presented technique was unique as it shortened the treatment time and esthetic results in smile and vertical proportions were achieved.

  8. Longitudinal eruptive and posteruptive tooth movements, studied on oblique and lateral cephalograms with implants.

    Science.gov (United States)

    Zhang, Xiaoyun; Baumrind, Sheldon; Chen, Gui; Chen, Huizhong; Liang, Yi; Xu, Tianmin

    2018-05-01

    The purpose of this study was to investigate the eruptive and posteruptive tooth displacements of untreated growing subjects longitudinally and the potential connections between posteruptive displacement of the maxillary and mandibular first molars and skeletal facial growth. The sample comprised 11 series of right 45° oblique cephalograms and lateral cephalograms of untreated children with metallic implants of the Björk type obtained from the archives of a growth study. Cephalograms generated at approximately 2-year intervals between the ages of 8.5 and 16 years were selected and traced. Superimpositions of serial tracings of oblique cephalograms on stable intraosseous implants were made to determine the displacements of buccal segment teeth in both arches, and superimpositions of serial tracings of lateral cephalograms were used to evaluate growth of the jaws. Continuous mesial tipping of the maxillary molars was observed from 8.5 to 16 years of age, averaging 8.2° ± 5.5° for the first molars and 18.3°± 8.5° for the second molars. Compared with the maxillary molars, the mandibular first molars showed less change in angulation except in the later mixed dentition when more than half of the subjects had accelerated forward tipping of the first molar in the late mixed dentition associated with migration into the leeway space. Average amounts of cumulative eruption from 8.5 to 16 years of age were 12.1 ± 2.1 mm downward and 3.8 ± 1.7 mm forward for the maxillary first molar. The mandibular first molar showed 8.6 ± 2.3 mm of eruption and 4.4 ± 1.9 mm of mesial migration. Peak velocity of vertical eruption of the maxillary and mandibular first molars corresponded to the skeletal vertical growth spurt. The maxillary canines and first premolars showed remarkable and continuous uprighting migration during eruption, averaging 9.5° ± 5.0° and 10.5° ± 6.7°, respectively. However, when they erupted into the occlusion, their changes in

  9. Oral Rehabilitation with Implant-Retained Overdenture in a Patient with Down Syndrome.

    Science.gov (United States)

    Altintas, Nuray Yilmaz; Kilic, Serdar; Altintas, Subutay Han

    2017-01-24

    Down syndrome, known as trisomy 21, is the most common chromosomal disorder. The disorder affects mental and systemic development as well as oral structure, including dental anomalies, high susceptibility of periodontal disease, and poor quality of alveolar bone. This report presents a case of dental rehabilitation by means of dental implants of a patient with Down syndrome. Two titanium dental implants were placed in the maxilla, and three titanium dental implants were installed in the mandible. One implant was lost during the osseointegration period. The prosthetic rehabilitation was performed with implant-retained maxillary and mandibular overdentures with the Locator attachment system. After a 2-year follow-up period, the patient was doing well, and all implants were clinically stable with no signs of bone loss or inflammation. The present study emphasizes that implant-retained overdentures with Locator attachment system could be a therapeutic option even for patients with Down syndrome. This therapy prevents crestal bone loss around the implants, improves functional and esthetic outcomes, and provides optimum oral hygiene for patients with mild mental impairment. Careful patient selection and education of patients and caregivers are essential considerations for a successful and safe treatment with dental implants in Down syndrome patients. © 2017 by the American College of Prosthodontists.

  10. The radiographic localization of unerupted maxillary incisors and supernumeraries

    International Nuclear Information System (INIS)

    Kim, Jae Duk; Lee, Chang Yul; You, Choong Hyun

    2003-01-01

    To evaluate the use of the vertical tube shift from a panoramic film and a periapical film to localize unerupted maxillary incisors and supernumeraries. The total of 103 displaced maxillary incisors or embedded supernumeraries were examined in this study. The vertical tube shift technique with panoramic and periapical radiography by normal projection taken and compared to localize the position of the embedded maxillary incisors or supernumeraries by a radiologist and 5 general dentists. The gold standard used for the radiographic comparisons was the true position of the embedded tooth as confirmed by horizontal tube shift technique using three periapical radiographs. The general dentist examiners were instructed on the use of the modified acronym 'SLDOBU' by the radiologist as it pertains to panoramic radiographs as the principle of vertical tube shift. All of the embedded maxillary incisors and supernumeraries were successfully located using the vertical tube shift from a panoramic and a maxillary anterior periapical radiograph by the radiologist and 5 general dentists. The use of a panoramic film with a periapical film combination for a vertical tube shift can be useful to localize unerupted maxillary incisors and supernumeraries.

  11. Long-Term Effect of Maxillary Distraction Osteogenesis (DO) on Nasal Index in Adult Patients with Cleft Lip and Palate Deformities.

    Science.gov (United States)

    Jena, Ashok Kumar; Rattan, Vidya; Singh, Satinder Pal; Utreja, Ashok Kumar; Sombir, Singh

    2016-03-01

    To test the hypothesis that there is no immediate and long-term effects of maxillary distraction osteogenesis (DO) on nasal index among adult subjects with cleft lip and palate deformities. Twelve adult subjects in the age range of 17-20 years with complete unilateral cleft lip and palate underwent advancement of maxilla by DO. The immediate and long-term effects of maxillary DO on nasal index were evaluated from extra-oral full face frontal photographs recorded prior to DO (T0), at the end of active DO (T1) and at least 2-years after the DO (T2). The ANOVA, Post Hoc test (Bonferroni) and Pearson correlation coefficients were used. The probability value (P value) 0.05 was considered as statistically significant. SNM angle and Ptm-M distance increased significantly by DO (P distraction (T1) and by 12.69 to 97.84 ± 9.14 % at the end of long-term follow-up (T2). The correlation between sagittal maxillary advancement and nasal index was statistically significant (P maxillary advancement, the nasal index increased by 1.38 % and 1.8 % at the end of active distraction and long-term follow-up respectively. The advancement of maxilla by distraction osteogenesis among subjects with cleft lip and palate deformities increased nasal index significantly.

  12. Inclination of the infraorbital canal studied on dry skulls expresses the maxillary growth pattern: a new contribution to the understanding of change in inclination of ectopic canines during puberty

    DEFF Research Database (Denmark)

    Caspersen, Louise M; Christensen, Ib J; Kjær, Inger

    2009-01-01

    Objective. The purpose of this study was to analyze the correlation between direction of the infraorbital canal and maxillary width on frontal radiographs of dry human skulls. Material and methods. Forty-two symmetrical, dry human skulls (late adolescence and adult) with no dental or skeletal...... anomalies. Frontal radiographs were taken of each skull placed in the Frankfort horizontal plane, with a radiopaque marker in the infraorbital canal. The maxillary transversal growth pattern was expressed as the infraorbital transversal angle (IOt) formed between a line through the contour of the bilateral...

  13. Using implants for prosthodontic rehabilitation of a 4-year-old with ectodermal dysplasia.

    Science.gov (United States)

    Toomarian, Lida; Ardakani, Mohammad Reza Talebi; Ramezani, Jamileh; Adli, Amin Rezaei; Tabari, Zahra Alizadeh

    2014-01-01

    Ectodermal dysplasia (ED) is an inherited disorder that affects ectodermally derived organs, such as teeth. Pathogenesis is thought to involve an altered epithelium-mesenchymal interaction. ED patients have oligodontia (or sometimes anodontia) in addition to other abnormalities involving the skin, sweat glands, or hair. Many different subtypes have been introduced in the literature. This article describes the case of a 4-year-old patient who, after being diagnosed with ED, was put on a treatment plan that involved mandibular implants, reshaping of the maxillary primary central incisors, and prosthetic dental rehabilitation. Due to the child's rapid growth, both dentures were changed 9 months post-treatment. Two years post-treatment, the maxillary denture was changed again and the child was placed under close supervision.

  14. Piezosurgery applied to implant dentistry: clinical and biological aspects.

    Science.gov (United States)

    Pereira, Cassiano Costa Silva; Gealh, Walter Cristiano; Meorin-Nogueira, Lamis; Garcia-Júnior, Idelmo Rangel; Okamoto, Roberta

    2014-07-01

    Piezosurgery is a new and modern technique of bone surgery in implantology. Selective cutting is possible for different ultrasonic frequencies acting only in hard tissues (mineralized), saving vital anatomical structures. With the piezoelectric osteotomy technique, receptor site preparation for implants, autogenous bone graft acquistition (particles and blocks), osteotomy for alveolar bone crest expansion, maxillary sinus lifting, and dental implant removal can be performed accurately and safely, providing excellent clinical and biological results, especially for osteocyte viability. The aim of this review was, through literature review, to present clinical applications of piezosurgery in implant dentistry and outline their advantages and disadvantages over conventional surgical systems. Moreover, this study addressed the biological aspects related to piezosurgery that differentiate it from those of bone tissue approaches. Overall, piezosurgery enables critical operations in simple and fully executable procedures; and effectively, areas that are difficult to access have less risk of soft tissue and neurovascular tissue damage via piezosurgery.

  15. Quantitative analysis of the relationship between maxillary incisors and the incisive canal by cone-beam computed tomography in an adult Japanese population

    Directory of Open Access Journals (Sweden)

    Tomonari Matsumura

    2017-08-01

    Full Text Available Abstract Background In setting goals for orthodontic treatment, determining the morphologies of the alveolar bone and maxillary incisor root is important for avoiding root resorption, dehiscence, and fenestration. This study aimed to analyze the configurational relationships among maxillary incisors, the alveolar border, and the incisive canal by cone-beam computed tomography (CBCT. Methods Cone-beam CT images of 93 orthodontic patients were evaluated for length of the incisive canal (L; angles between the palatal plane and the maxillary alveolar border (θ1, the incisive canal (θ2, and maxillary incisor (θ3; distance from the left maxillary incisor to the incisive canal (D; and cross-sectional areas of the incisive canal (CSAs at three vertical levels. Comparison of variables between male and female patients was performed with the two-sample t test. Correlations between parameters were examined by Pearson’s correlation analysis and Bonferroni correction for multiple comparisons. Results Male patients exhibited significantly greater values of L than female patients. There were significant positive correlations between θ1 and θ2, θ2 and θ3, and θ3 and θ1. While the value of D was the lowest at the oral opening, that of the cross-sectional area of the incisive canal (CSA was the greatest at the incisal root apex. Conclusions This study demonstrated that the incisive canal had large inter-individual variability, and the proximity between the incisive canal and the incisal root could not be precisely predicted by the conventional cephalograms. Therefore, pre-treatment CBCT examination should be recommended when a large amount of maxillary anterior retraction and/or intrusion is planned in orthodontic diagnosis.

  16. Interceptive treatment of palatal impaction of maxillary canines with rapid maxillary expansion: a randomized clinical trial.

    Science.gov (United States)

    Baccetti, Tiziano; Mucedero, Manuela; Leonardi, Maria; Cozza, Paola

    2009-11-01

    Our aim in this prospective randomized clinical study was to assess the prevalence rate of eruption of palatally displaced canines, diagnosed at an early developmental stage with posteroanterior radiographs and consequently treated by rapid maxillary expansion. A sample of 60 subjects in the early mixed dentition with palatally displaced canines diagnosed on posteroanterior radiographs was enrolled in the trial. Their age range at the first observation (T1) was 7.6 to 9.6 years, with a prepubertal stage of skeletal maturity (CS1 or CS2). The 60 subjects were randomly allocated to the treatment group (TG, 35 subjects) or the no-treatment group (NTG, 25 subjects). The TG was treated with a banded rapid maxillary expander; after expansion, all patients were retained with the expander in place for 6 months. Thereafter, the expander was removed, and the patients wore a retention plate at night for a year. The NTG received no treatment. All subjects were reevaluated in the early permanent dentition (T2) (postpubertal CS4). The number of dropouts was recorded. The main outcome recorded at T2 was successful or unsuccessful eruption of the maxillary permanent canines. The starting forms at T1 for measurements on posteroanterior and panoramic films were compared in the 2 groups with the Mann-Whitney U test (P <0.05). The prevalence rates of successful and unsuccessful treatments in the TG were compared with those in NTG with chi-square tests (P <0.05). From T1 to T2, there were 3 dropouts in each group. The final sample comprised 32 subjects in the TG and 22 subjects in the NTG. No statistically significant differences were found for any variable at T1. The prevalence rates of successful eruption of the maxillary canines were 65.7% (21 subjects) in the TG and 13.6% (3 subjects) in the NTG. The comparison was statistically significant (chi-square = 12.4; P <0.001). Subjects with palatally displaced canines in the early mixed dentition do not have transverse deficiency of the

  17. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    Science.gov (United States)

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is 90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  18. Ectopic third molar in maxillary sinus: A rare case report

    Directory of Open Access Journals (Sweden)

    Abhishek Sinha

    2017-01-01

    Full Text Available Ectopic tooth eruption in a non-dental area is a rare entity, and is most common in oral cavity. There have been a few case reports of teeth erupting in mandibular condyle, chin, palate, coronoid process, and maxillary sinus. Ectopic tooth in the maxillary sinus are found incidentally on routine radiological examination, same time they can be symptomatic and associated with pathologies usually dentigerous cyst or odontogenic keratocyst. Facial pain, purulent rhinorrhoea, epistaxis, headache, swelling, and epiphora-related naso-lacrimal duct obstruction can also be seen. By Caldwell-Luc procedure the ectopic teeth within the maxillary sinus are often removed. In this study, a case of ectopic maxillary third molar tooth on right maxillary sinus is presented.

  19. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Shrikar R Desai

    2013-01-01

    Full Text Available Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45° to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement and Von mises stress were found to be lower for tapered long implant (10 mm than short implant (6 mm while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  20. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    Science.gov (United States)

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  1. Cephalometric evaluation of maxillary retrognathism cases treated with FR-3 appliance.

    Science.gov (United States)

    Biren, S; Erverdi, N

    1993-09-01

    The purpose of this investigation was to evaluate the efficiency of the FR-3 appliance on functional Cl III malocclusion cases. A total of 45 functional Cl III cases were chosen from a general clinic intake of which 25 were treated with the FR-3 appliance and 20 were untreated and were taken as a control group. Patients that were treated with FR-3 had the following characteristics: Cl III with maxillary deficiency; functional anterior cross-bite; absence of anterior open-bite; patients in mixed dentition. The mean age in the treatment group was 8.4 years 8.8 years in the control group. The observation period was one year for both groups. The results were as follows: Sagittal forward growth stimulation was not observed in the maxilla. Mandibular growth was redirected in the vertical direction. The SNB angle decreased in that the mandible rotated downward and backward. The ANB angle increased. There was an increase in total and lower anterior facial height and reduction in the overbite. Another skeletal change observed was the increase in the cranial flexure angle. Improved dental results were a significant amount of overjet increase and a decrease in the IMPA. There was also a beneficial effect on the soft tissue profile.

  2. Agenesis of maxillary lateral incisors and associated dental anomalies.

    Science.gov (United States)

    Garib, Daniela Gamba; Alencar, Bárbara Maria; Lauris, José Roberto Pereira; Baccetti, Tiziano

    2010-06-01

    The objectives of this study were to evaluate the prevalence of dental anomalies in patients with agenesis of maxillary lateral incisors and to compare the findings with the prevalence of these anomalies in the general population. A sample of 126 patients, aged 7 to 35 years, with agenesis of at least 1 maxillary lateral incisor was selected. Panoramic and periapical radiographs and dental casts were used to analyze other associated dental anomalies, including agenesis of other permanent teeth, ectopia of unerupted permanent teeth, microdontia of maxillary lateral incisors, and supernumerary teeth. The occurrence of these anomalies was compared with prevalence data previously reported for the general population. Statistical testing was performed with the chi-square test (P <0.05) and the odds ratio. Patients with maxillary lateral incisor agenesis had a significantly increased prevalence rate of permanent tooth agenesis (18.2%), excluding the third molars. The occurrence of third-molar agenesis in a subgroup aged 14 years or older (n = 76) was 35.5%. The frequencies of maxillary second premolar agenesis (10.3%), mandibular second premolar agenesis (7.9%), microdontia of maxillary lateral incisors (38.8%), and distoangulation of mandibular second premolars (3.9%) were significantly increased in our sample compared with the general population. In a subgroup of patients aged 10 years or older (n = 115), the prevalence of palatally displaced canines was elevated (5.2%). The prevalences of mesioangulation of mandibular second molars and supernumerary teeth were not higher in the sample. Permanent tooth agenesis, maxillary lateral incisor microdontia, palatally displaced canines, and distoangulation of mandibular second premolars are frequently associated with maxillary lateral incisor agenesis, providing additional evidence of a genetic interrelationship in the causes of these dental anomalies. 2010 American Association of Orthodontists. Published by Mosby, Inc. All

  3. A new computationally-efficient two-dimensional model for boron implantation into single-crystal silicon

    International Nuclear Information System (INIS)

    Klein, K.M.; Park, C.; Yang, S.; Morris, S.; Do, V.; Tasch, F.

    1992-01-01

    We have developed a new computationally-efficient two-dimensional model for boron implantation into single-crystal silicon. This paper reports that this new model is based on the dual Pearson semi-empirical implant depth profile model and the UT-MARLOWE Monte Carlo boron ion implantation model. This new model can predict with very high computational efficiency two-dimensional as-implanted boron profiles as a function of energy, dose, tilt angle, rotation angle, masking edge orientation, and masking edge thickness

  4. [Dental-radical cysts, a rare aetiology of maxillary sinus opacity].

    Science.gov (United States)

    Bassou, D; Darbi, A; Elkharras, A; Elhaddad, A; Boumdin, H; Amil, T; Benameur, M; Chaouir, S

    2007-12-01

    To specify CT scan roll in diagnosis of radicullar cyst invading maxillary sinus. Two cases of 23 and 34-year-old men presented with facial injury and sinusitis was explored by CT scan. CT scan showed in both patients a cystic lesion, developing into the maxillary sinus around a tooth apex and limits by a double dense thin rim. CT scan permits diagnosis of radicular cyst invading maxillary sinus, in the event of obscured maxillary sinus, when double dense thin rim corresponding to the repulsed wall of the sinus is looking.

  5. One-Piece Implant-Retained Mandibular Overdentures By Pre-Fabricated Titanium Telescopic Attachments and Frictional Varnish: A Two-Year Prospective Study.

    Science.gov (United States)

    Nik, Shahram Namjoy; Nejatian, Touraj

    2016-12-01

    Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading. Copyright© 2016 Dennis Barber Ltd.

  6. Anterior maxillary segmental distraction in the treatment of severe maxillary hypoplasia secondary to cleft lip and palate.

    Science.gov (United States)

    Li, Hongliang; Dai, Jiewen; Si, Jiawen; Zhang, Jianfei; Wang, Minjiao; Shen, Steve Guofang; Yu, Hongbo

    2015-01-01

    Anterior maxillary segmental distraction (AMSD) is an effective surgical procedure in the treatment of maxillary hypoplasia secondary to cleft lip and palate. Its unique advantage of preserving velopharyngeal function makes this procedure widely applied. In this study, the application of AMSD was described and its long-term stability was explored. Eight patients with severe maxillary hypoplasia secondary to CLP were included in this study. They were treated with AMSD using rigid external distraction (RED) device. Cephalometric analysis was performed twice at three time points for evaluation: before surgery (T1), after distraction (T2), and 2 years after treatment (T3). One-way analysis of variance was used to assess the differences statistically. All the distractions completed smoothly, and maxilla was distracted efficiently. The value of SNA, NA-FH, Ptm-A, U1-PP, overjet and PP (ANS-PNS) increased significantly after the AMSD procedure (P 0.05). Changes of palatopharyngeal depth and soft palatal length were insignificant. AMSD with RED device provided an effective way to correct maxillary hypoplasia secondary to CLP, extended the palatal and arch length, avoided damage on velopharyngeal closure function and reduced the relapse rate. It is a promising and valuable technique in this potentially complicated procedure.

  7. Maxillary-driven simultaneous maxillo-mandibular distraction for hemifacial microsomia.

    Science.gov (United States)

    Nakajima, Hideo; Sakamoto, Yoshiaki; Tamada, Ikkei; Ogata, Hisao; Kishi, Kazuo; Sakamoto, Teruo

    2011-12-01

    We treat hemifacial microsomia with a combination of surgery and orthodontic treatment during the growth period, resulting in early improvement in facial asymmetry and the induction of normal growth. We previously used gradual distraction of the mandibular ramus for Pruzansky's type II classification (Pruzansky, 1969). In type II cases, the maxilla should also be treated actively as, using this technique, improvement of the occlusal plane is difficult to achieve, resulting in a cross bite and difficulties in post-operative orthodontic treatment-especially in older patients. Morphologically, the mandibular angle region of the operative side is flat, and the angle of the mouth remains elevated. We performed mandibular-driven simultaneous maxillo-mandibular distraction while the occlusion was maintained using intermaxillary anchorage. However, mandibular-driven distraction tended to elongate the face because the mandible only elongated downwards and the mandibular ramus did not reach the glenoid. Furthermore, external distraction devices produce significant distress for patients until removal of the device and cause scars on the face. We developed a new internal distraction device with a variable angle and performed maxillary-driven simultaneous maxillo-mandibular distraction using this device. The result was morphologically satisfactory and solved the above problems. Because the patient was in the growth period, careful follow-up and induction to normal growth were important while the inferior growth of the affected side was monitored. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Ecological and phylogenetic influences on maxillary dentition in snakes

    Directory of Open Access Journals (Sweden)

    Kate Jackson

    2010-12-01

    Full Text Available The maxillary dentition of snakes was used as a system with which to investigate the relative importance of the interacting forces of ecological selective pressures and phylogenetic constraints indetermining morphology. The maxillary morphology of three groups of snakes having different diets, with each group comprising two distinct lineages — boids and colubroids — was examined. Our results suggest that dietary selective pressures may be more significantthan phylogenetic history in shaping maxillary morphology.

  9. Introduction of a new removable adjustable intraoral maxillary distraction system for correction of maxillary hypoplasia.

    Science.gov (United States)

    Figueroa, Alvaro A; Polley, John W; Figueroa, Alexander L

    2009-09-01

    Distraction osteogenesis has become a treatment alternative to treat severe craniofacial skeletal dysplasias. A rigid external distraction device has been successfully used to advance the maxilla as well as the maxillary, orbital, and forehead complex (monobloc) in children as young as 2 years, adolescents, and adults. For this severe group of patients, the technique has been found to be simpler and safer than traditional surgical methods. Maxillary and midfacial advancement through distraction has been found to be extremely stable in the patients in whom the technique was used.The authors introduce an intraoral distractor for those patients requiring a moderate maxillary advancement. The advantages of the device include ease of insertion, vector adjustability, reactivation capabilities, and no need for second procedure for its removal.The above approaches have provided predictable and stable results. A detailed description of the device, necessary orthodontic and surgical procedures, case reports, and cephalometric outcomes are presented. The techniques can be applied alone or as an adjunct to traditional orthognathic and craniofacial surgical procedures.

  10. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  11. Cell patterning on a glass surface by a mask-assisted ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chan-Hee; Kim, Dong-Ki; Hwang, In-Tae; Lim, Youn-Mook; Kim, Hae-Kyoung; Nho, Young-Chang [Radiation Research Division for Industry and Environment, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 580-185 (Korea, Republic of); Choi, Jae-Hak [Radiation Research Division for Industry and Environment, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 580-185 (Korea, Republic of)], E-mail: jaehakchoi@kaeri.re.kr

    2009-04-15

    A simple patterning method of cells on a glass has been developed by using ion implantation. The glass was implanted through a pattern mask with 150 keV Ar ions in the absence or presence of oxygen. Surface properties of the ion-implanted glass were investigated by means of X-ray photoelectron spectroscopy, contact angle measurement and cell culture test. The results showed that more hydrophilic groups were formed on the glass surface implanted in the presence of oxygen. Thus, the glass surface implanted in the presence of oxygen showed lower contact angle compared with the glass surface implanted in the absence of oxygen. The cells were strongly adhered to and proliferated on the ion-implanted regions of the glass. The cell population was found to be the highest on the glass implanted at a fluence of 1 x 10{sup 16} ions/cm{sup 2} in the presence of oxygen.

  12. Maxillary Osteomyelitis: A Rare Entity

    Directory of Open Access Journals (Sweden)

    Ayaaz Habib

    2016-01-01

    Full Text Available Osteomyelitis of the maxilla is now a rare event with the advent of antibiotics. The two predominant causes are odontogenic infections and sinusitis. Immunocompromised states such as diabetes, HIV, and malnutrition increase the risk of osteomyelitis. It is important to recognize this early as it is a difficult entity to treat with potentially serious consequences. We report an unusual case of right sided maxillary osteomyelitis in a lady with poorly controlled diabetes in rural Lincolnshire. Biopsy of the right maxillary bone showed features of acute osteomyelitis. This responded well to a prolonged course of oral antibiotics.

  13. Mastication improvement after partial implant-supported prosthesis use.

    Science.gov (United States)

    Gonçalves, T M S V; Campos, C H; Gonçalves, G M; de Moraes, M; Rodrigues Garcia, R C M

    2013-12-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor and food comminution index was determined with the sieving method. Masseter and temporal muscle thicknesses during rest and maximal clenching were also evaluated by ultrasonography. Each maxillary arch received a new complete denture that was used throughout the study. Data were analyzed by analysis of variance for repeated measures, followed by the Tukey test (p mastication, and the magnitude of this effect was related to prosthesis type.

  14. A radiographic study of the experimental lesions in the maxillary sinus

    International Nuclear Information System (INIS)

    Lee, Joo Hyun; Hwang, Eui Hwan; Lee, Sang Rae

    1994-01-01

    The purpose of this study was to examine the differences in representation of a globular radiopaque mass on the pantomograms and Waters' views and to compare the efficacy of periapical radiograms, pantomograms and Waters' views in detection of defects on the internal walls of the maxillary sinus. This study was performed with dried human skull. For the study of difference of radiopaque mass shadow in the two views, rubber ball with a diameter of 10mm was used as the experimental lesion. It was placed successively on the internal wall of the anterior, posterior, medial, lateral walls and floor of the maxillary sinus. To examine the detectability of defects for radiographic techniques, defects were formed in the anterior, posterior, medial, lateral walls, and floor of the maxillary sinus. They were formed with 0.5 mm, 0.75 mm, 1.0 mm, 2.0 mm and 3.0 mm sized steel round burs with a slow speed dental handpiece. By subsequently plugging the holes with zinc oxide eugenol paste, radiopaque defects were produced. After that the periapical radiograms, the pantomograms and the Waters' views were taken each and every defect. The obtained results were as follows: 1. Rubber balls placed on each internal wall of maxillary sinus were correctly depicted on the posterior wall and the floor in case of the pantomogram, and on the anterior wall and the medial wall in case of the Waters' view. 2. On the detectability of defects for each radiographic technique, radiolucent defects were detected in different places of each technique. Periapical radiogram could detect 1.0 mm defect on the floor of the maxillary sinus, pantomogram could detect 2.0 mm defect on every internal wall of the maxillary sinus, and Waters' view could detect 3.0 mm defect on the anterior wall of the maxillary sinus. 3. On the detectability of defects for each radiographic technique, radiopaque defects were detected in different places for each technique. Periapical radiogram could clearly detect 0.5 mm defect on

  15. Atypical presentation of bilateral supplemental maxillary central incisors with unusual talon cusp

    Directory of Open Access Journals (Sweden)

    Sivakumar Nuvvula

    2011-01-01

    Full Text Available Delayed eruption of maxillary permanent central incisors in a child poses a distressing esthetic quandary to parents, by virtue of its location in the dental architecture. Well-aligned anterior teeth add confidence to smile and have enhanced self-esteem, which is critical even in early life. Impaction of the maxillary central incisors compared to third molars or the canines is less reported; bilateral supplemental maxillary central incisors related to impacted permanent maxillary central incisors are rare and one of the supplemental central incisors showing unusual talon is still infrequent. A case of impacted maxillary permanent central incisors related to supplemental maxillary central incisors, with one of them showing an unusual talon cusp, is presented.

  16. On the Feasibility of Utilizing Allogeneic Bone Blocks for Atrophic Maxillary Augmentation

    Directory of Open Access Journals (Sweden)

    Alberto Monje

    2014-01-01

    Full Text Available Purpose. This systematic review was aimed at assessing the feasibility by means of survival rate, histologic analysis, and causes of failure of allogeneic block grafts for augmenting the atrophic maxilla. Material and Methods. A literature search was conducted by one reviewer in several databases. Articles were included in this systematic review if they were human clinical trials in which outcomes of allogeneic bone block grafts were studied by means of survival rate. In addition other factors were extracted in order to assess their influence upon graft failure. Results. Fifteen articles fulfilled the inclusion criteria and subsequently were analyzed in this systematic review. A total of 361 block grafts could be followed 4 to 9 months after the surgery, of which 9 (2.4% failed within 1 month to 2 months after the surgery. Additionally, a weighed mean 4.79 mm (95% CI: 4.51–5.08 horizontal bone gain was computed from 119 grafted sites in 5 studies. Regarding implant cumulative survival rate, the weighed mean was 96.9% (95% CI: 92.8–98.7%, computed from 228 implants over a mean follow-up period of 23.9 months. Histologic analysis showed that allogeneic block grafts behave differently in the early stages of healing when compared to autogenous block grafts. Conclusion. Atrophied maxillary reconstruction with allogeneic bone block grafts represents a reliable option as shown by low block graft failure rate, minimal resorption, and high implant survival rate.

  17. Influence of artificial aging on the load-bearing capability of straight or angulated zirconia abutments in implant/tooth-supported fixed partial dentures.

    Science.gov (United States)

    Nothdurft, Frank P; Doppler, Klaus E; Erdelt, Kurt J; Knauber, Andreas W; Pospiech, Peter R

    2010-01-01

    The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments used in ZirDesign (Astra Tech) implant/tooth-supported fixed partial dentures (FPDs) in the maxilla. Four different test groups (n = 8) representing anterior implant/tooth-supported FPDs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (maxillary left central incisor) from a prosthetic point of view, which allowed for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position that required an angulated (20-degree) abutment. OsseoSpeed implants (4.5 3 13 mm, Astra Tech) as well as metal tooth analogs (maxillary right lateral incisor) with simulated periodontal mobility were mounted in polymethyl methacrylate. The FPDs (chromium-cobalt alloy) were cemented with glass ionomer. Groups 2 and 4 were thermomechanically loaded and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples survived thermomechanical loading. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the straight abutments or the angulated abutments. The restorations that used angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1: 209.13 ± 39.11 N; group 2: 233.63 ± 30.68 N; group 3: 324.62 ± 108.07 N; group 4: 361.75 ± 73.82 N). This difference in load-bearing performance was statistically significant, both with and without artificial aging. All abutment fractures occurred below the implant shoulder. Compensation for angulated implant positions with an angulated zirconia abutment is possible without reducing the load-bearing capacity of implant/tooth-supported anterior FPDs.

  18. Marginal bone loss evaluation around immediate non-occlusal microthreaded implants placed in fresh extraction sockets in the maxilla: a 3-year study.

    Science.gov (United States)

    Calvo-Guirado, José L; Gómez-Moreno, Gerardo; Aguilar-Salvatierra, Antonio; Guardia, Javier; Delgado-Ruiz, Rafael A; Romanos, Georgios E

    2015-07-01

    To evaluate marginal bone loss over 3 years around immediate microthreaded implants placed in the maxillary anterior/esthetic zone and immediately restored with single crowns. Seventy-one implants (with microthreads up to the platform--rough surface body and neck, internal connection and platform switching) were placed in fresh extraction sockets in the maxillary arches of 30 men and 23 women (mean age 37.85 ± 7.09 years, range 27-60). All subjects had at least 3 mm of soft tissue to allow the establishment of adequate biologic width and to reduce bone resorption. Each patient received a provisional restoration immediately after implant placement with slight occlusal contact. Mesial and distal bone height was evaluated using digital radiography on the day following implant placement (baseline) and after 1, 2, and 3 years. Primary stability was measured with resonance frequency analysis. No implants failed, resulting in a cumulative survival rate of 100% after 3 years. Marginal bone loss from implant collar to bone crest measured at baseline (peri-implant bone defect at the fresh extraction socket) and after 3 years was 0.86 mm ± 0.29 mm. Mesial and distal site crestal bone loss ranged from 3.42 mm ± 1.2 mm at baseline to 3.51 mm ± 1.5 mm after 3 years (P = 0.063) and from 3.38 mm ± 0.9 mm at baseline to 3.49 mm ± 0.9 mm after 3 years, respectively (P = 0.086). This prospective study found minimal marginal bone loss and a 100% implant survival rate over the 3-year follow-up for microthreaded immediate implants subjected to immediate non-occlusal loading. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Reasons for mini-implants failure: choosing installation site should be valued!

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-04-01

    Full Text Available Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1 Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2 Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3 Low bone density, low thickness and low alveolar bone volume; 4 Low alveolar cortical bone thickness; 5 Excessive pressure inducing trabecular bone microfracture; 6 Sites of higher anatomical weakness in the mandible and the maxilla; 7 Thicker gingival tissue not considered when choosing the mini-implant.

  20. Maxillary sinus agenesis - report of two cases

    International Nuclear Information System (INIS)

    Pierre, Jorge Henrique Arraes de Alencar; Santana, Expedito Araujo

    2000-01-01

    Agenesis or aplasia of the maxillary sinuses is an extremely rare condition, and only eight cases have been reported in the world medical literature. These malformations may arise as a result of developmental defects. Two cases of unilateral agenesis of the maxillary sinus are presented and the radiological abnormalities and the embryology are discussed. The literature is also reviewed. (author)

  1. Three-year treatment outcomes with three brands of implants placed in the posterior maxilla and mandible of partially edentulous patients

    NARCIS (Netherlands)

    Ozkan, Yasar; Ozcan, Mutlu; Akoglu, Burcin; Ucankale, Mert; Kulak-Ozkan, Yasemin

    Statement of problem. Survival rates of implants in posterior regions vary among clinical studies. Problems occur more often in the posterior segment of the maxilla due to proximity of the maxillary sinus and reduced quality or quantity of alveolar bone. Purpose. This clinical study evaluated the

  2. Light weight hollow maxillary complete denture: A case series

    Directory of Open Access Journals (Sweden)

    Laxman Singh Kaira

    2012-01-01

    Full Text Available Retention, stability and support are the basic principles on which the success of a complete denture relies on. The skill lies in applying these principles efficiently in critical situations. Residual ridge resorption occurs at a three times faster rate in mandibular arch than in the maxillary arch. The severely resorbed maxillary and mandibular edentulous arches that are narrow and constricted with increased interarch space provide decreased support, retention and stability. The consequent weight of the processed complete denture only compromises them further. The severely resorbed jaw can have various treatment options. Extreme resorption of the maxillary denture-bearing area may lead to problems with prosthetic rehabilitation. The advantage of a hollow maxillary or mandibular denture is the reduction of excessive weight of acrylic resin, which normally replaces lost alveolar ridge in the interridge space of the denture wearer. This clinical report describes two case reports of edentulous patients with resorbed ridges where a simplified technique of fabricating a light weight hollow maxillary complete denture was used for the preservation of denture bearing areas.

  3. Esthetic evaluation of single-tooth implants in the anterior maxilla following autologous bone augmentation.

    Science.gov (United States)

    Hof, M; Pommer, B; Strbac, G D; Sütö, D; Watzek, G; Zechner, W

    2013-08-01

    Autologous bone augmentation to rebuild compromised alveolar ridge contour prior to implant placement allows for favorable three-dimensional implant positioning to achieve optimum implant esthetics. The aim of the present study was to evaluate peri-implant soft tissue conditions around single-tooth implants following bone grafts in the esthetic zone of the maxilla. Sixty patients underwent autologous bone augmentation of deficient maxillary sites prior to placement of 85 implants in the esthetic zone. In case of multiple implants per patient, one implant was randomly selected. Objective evaluation of 60 single-tooth implants was performed using the Pink-Esthetic-Score (PES) and Papilla Index (PI) and supplemented by subjective patient evaluation, as well as clinical and radiologic examination. Objective ratings of implant esthetics were satisfactory (median PES: 11, median PI: 2) and significantly correlated with high patient satisfaction (mean VAS score: 80%). Both esthetic indices demonstrated respectable levels of inter- as well as intra-observer agreement. Poor implant esthetics (low PES and PI ratings) were significantly associated with increased anatomic crown height, while no influence of horizontal implant-tooth distance could be found. The present investigation indicates that favorable esthetic results may be achieved in the augmented anterior maxilla. However, bony reconstruction of compromised alveolar ridges does not guarantee optimum implant esthetics. © 2011 John Wiley & Sons A/S.

  4. A systematic review on immediate loading of implants used to support overdentures opposed by conventional prostheses : factors that might influence clinical outcomes

    NARCIS (Netherlands)

    Zygogiannis, K.; Wismeijer, D.; Aartman, I.H.A.; Osman, R.B.

    2016-01-01

    Purpose: Different treatment protocols in terms of number, diameter, and suprastructure design have been proposed for immediately loaded implants that are used to support mandibular overdentures opposed by maxillary conventional dentures. The aim of this study was to investigate the influence of

  5. Maxillary sinus floor augmentation with Bio-Oss or Bio-Oss mixed with autogenous bone as graft: a systematic review

    DEFF Research Database (Denmark)

    Jensen, Thomas; Schou, Søren; Stavropoulos, Andreas

    2012-01-01

    Aims: The objective of the present systematic review was to test the hypothesis of no differences in the implant treatment outcome when Bio-Oss or Bio-Oss mixed with autogenous bone is used as graft for the maxillary sinus floor augmentation (MSFA) applying the lateral window technique. Material...... and methods: A MEDLINE (PubMed) search in combination with a hand search of relevant journals was conducted by including human studies published in English from January 1, 1990 to June 1, 2010. The search provided 879 titles and 35 studies fulfilled the inclusion criteria. Considerable variation...... in the included studies prevented meta-analysis from being performed and no long-term study comparing MSFA with the two treatment modalities was identified. Also, the survival of suprastructures after the two augmentation procedures was not compared within the same study. Results: The 1-year implant survival...

  6. Trans-sinusoidal maxillary distraction in three cleft patients.

    NARCIS (Netherlands)

    Wenghoefer, M.H.; Martini, M.; Nadjmi, N.; Schutyser, F.A.C.; Jagtman, A.K.; Bergé, S.J.

    2006-01-01

    The trans-sinusoidal maxillary distractor (TS-MD) was used to achieve maxillary advancement in three patients with repaired cleft lip and palate. After preoperative computer-aided planning of the distraction vectors, each TS-MD was bent on a stereolithographic model of the maxilla of the patient.

  7. Treatment of severe maxillary cleft hypoplasia in a case with missing premaxilla with anterior maxillary distraction using tooth-borne hyrax appliance

    Directory of Open Access Journals (Sweden)

    Akshai Shetty

    2015-01-01

    Full Text Available Cleft orthodontics generally poses a challenge and a missing premaxilla adds to the difficulty in managing them. The lack of bone support and anterior teeth in a case with missing premaxilla accounts not only for difficulty in rehabilitation but also in increasing the maxillary hypoplasia. This article presents a case report where planned orthodontic and surgical management using distraction has helped treat a severe maxillary hypoplasia in a patient with missing premaxilla. The treatment plan and method can be used to treat severe maxillary hypoplasia and yield reasonably acceptable results for such patients.

  8. Penetration of flomoxef into human maxillary and mandibular bones.

    Science.gov (United States)

    Igawa, H H; Sugihara, T; Yoshida, T; Kawashima, K; Ohura, T

    1995-09-01

    Penetration of flomoxef into the maxillary and mandibular bones was assayed clinically to provide data about its usefulness for the prevention of postoperative infection after maxillofacial surgery. Twenty-one patients undergoing maxillofacial surgery at our department were given flomoxef 2 g dissolved in 20 ml of physiological saline intravenously over 3 minutes during operation, and the serum, maxillary and mandibular concentrations were measured 1, 3, and 6 hours after injection by the band culture method using Escherichia coli 7437 as the indicator strain. The mean concentrations were 53.4, 16.1, and 2.6 micrograms/ml, respectively, in the serum, 17.6, 7.8, and 1.0 micrograms/g in maxillary bone, and 16.4, 4.2, and 0.9 micrograms/g in mandibular bone. The mean bone:serum ratios at 1, 3, and 6 hours were 33.0%, 48.2%, and 36.8%, respectively, for maxillary bone, and 30.7%, 26.2%, and 35.7% for mandibular bone. When compared with previously reported data on the bone:serum ratios in jaw of various other intravenous antibiotics, our results show that penetration of flomoxef into maxillary and mandibular bone is extremely high. As all the intramaxillary and intramandibular concentrations exceed its MIC80 values against clinical isolates of bacteria frequently isolated in cases of infection in the oral and maxillofacial region, it is apparent that one intravenous shot of flomoxef 2 g allows penetration of the drug into the maxillary and mandibular bones at effective concentrations. Flomoxef is therefore potentially useful for the prevention and treatment of infections in the oral and maxillofacial region, as it has excellent penetration into the maxillary and mandibular bones.

  9. Transpalatal distraction for the management of maxillary constriction in pediatric patients.

    Science.gov (United States)

    Adolphs, Nicolai; Ernst, Nicole; Hoffmeister, Bodo; Raguse, Jan-Dirk

    2015-01-01

    The management of severe maxillary constriction can be challenging. For that purpose surgically assisted maxillary expansion by transpalatal distraction (TPD) can typically be recommended after skeletal maturity. However in selected cases bone borne transpalatal distraction devices can contribute to improve maxillary constriction considerably earlier already during mixed dentition. To assess the possibility of bone borne transpalatal distraction in pediatric patients. Clinical paper. Since 2010 TPD has been applied to six pediatric patients during mixed dentition when severe maxillary constriction was present and conventional orthodontic widening has already failed. Individually selected devices (Surgitec, Belgium) were inserted in general anaesthesia and distraction was performed according to well known parameters. Maxillary constriction could be improved in all six patients without any drawbacks by bone borne devices during mixed dentition. Skeletal conditions were obviously improved for subsequent orthodontic or orthognathic therapy without functional impairment. Follow-up is up to 36 months after device removal. Transpalatal Distraction is recommendable in selected pediatric patients if massive growth disturbance is present or has to be expected. TPD allows for individually adapted maxillary expansion by selection and positioning of appropriate devices in combination with intraoperative testing of maxillary movements and controlled bone removal.

  10. Rapid maxillary expansion in contemporary orthodontic literature

    Directory of Open Access Journals (Sweden)

    Sabrina Mutinelli

    2016-01-01

    Full Text Available We have reviewed our retrospective research about rapid maxillary expansion performed in the early mixed dentition to summarize the results of different studies regarding maxillary dental arch width variation and crowding improvement in light of contemporary literature. The aim is to define the effects of treatments followed until the end of dental arch growth. In all studies, a Haas expander anchored to the deciduous dentition was used. The samples consisted of treated patients with and without a lateral crossbite and homogeneous untreated individuals as controls. Two additional control groups of adolescents and adults in dental Class 1 were also compared. As a result of the analysis, rapid maxillary expansion with anchorage to the deciduous dentition was found to be effective in increasing transverse width in intermolar and intercanine areas, and the change was preserved until the full permanent dentition stage. When performed before maxillary lateral incisors have fully erupted, this procedure allows for a rapid increase in the arch length in the anterior area and consequently, in the space available for permanent incisors with a stable reduction in crowding over time.

  11. Asymmetric rapid maxillary expansion in true unilateral crossbite malocclusion: a prospective controlled clinical study.

    Science.gov (United States)

    Ileri, Zehra; Basciftci, Faruk Ayhan

    2015-03-01

    To investigate the short-term effects of the asymmetric rapid maxillary (ARME) appliance on the vertical, sagittal, and transverse planes in patients with true unilateral posterior crossbite. Subjects were divided into two groups. The treatment group was comprised of 21 patients with unilateral posterior crossbite (mean age  =  13.3 ± 2.1 years). Members of this group were treated with the ARME appliance. The control group was comprised of 17 patients with Angle Class I who were kept under observation (mean age  =  12.3 ± 0.8 years). Lateral and frontal cephalograms were taken before the expansion (T1), immediately after expansion (T2), and at postexpansion retention (T3) in the treatment group and at preobservation (T1) and postobservation (T2) in the control group. A total of 34 measurements were assessed on cephalograms. For statistical analysis, the Wilcoxon test and analysis of covariance were used. The ARME appliance produced significant increases in nasal, maxillary base, upper arch, and lower arch dimensions (P ARME appliance created asymmetric increments in the transversal dimensions of the nose, maxilla, and upper arch in the short term. Asymmetric expansion therapy for subjects with unilateral maxillary deficiency may provide satisfactory outcomes in adolescents, with the exception of mandibular arch expansion. The triangular pattern of expansion caused clockwise rotation of the mandible and the occlusal plane and produced significant alterations in the vertical facial dimensions, whereas it created no displacement in maxilla in the sagittal plane.

  12. Reduction of implantation shadowing effect by dual-wavelength exposure photo process

    CERN Document Server

    Gu, Yiming; Lee Sang Yun; Roche, William; Sturtevant, John

    2003-01-01

    As transistor engineering continues to well below 100 nm length devices, ion implantation process tolerances are making these formerly "non-critical" lithography levels more and more difficult. In order to minimize the channeling effect and to obtain a controllable profile of dopant, an angle implantation is often required. However, a shadow area of resist pattern is always accompanied with an angle implantation. This shadowing effect consumes silicon real estate, and reduces the line edge placement (LEP) tolerances. Therefore, methodologies to reduce the shadowing effect in angled implantation become a critical consideration not only for device engineering but also for photolithography. Based on the model analysis, simulation and experiments, this paper presents an effective novel process utilizing dual-wavelength exposure (DWE) to reduce the shadowing effect. The DWE process is realized by two consecutive exposures for an I-line resist with a DUV stepper/scanner and an I-line stepper. The process leverages ...

  13. A Peduncular Cystic Compound Odontoma on the Posterior Wall of the Maxillary Sinus

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Chul [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chonam National University, Kwangju (Korea, Republic of)

    1998-08-15

    A cystic compound odontoma in the maxillary sinus occurred in a 13-years-old boy, who had missing right upper third molar without having the history of extraction of the wisdom tooth. He complained nasal stuffiness, headache, and pain on the affected face, resembling any sign and symptoms of the maxillary sinus problems. The cysteic compound, sized 2 x 1.5 cm in diameter was pedunculated and attached on the posterior wall of the right maxillary sinus and above the antral floor. The location of the compound odontoma in the maxillary sinus was confirmed after panoramic, waters, spiral tomographic, CT examinations and surgical exploration. Irs location was on the medical, posterior, superior to the normal position of the maxillary third molar or the maxillary dental arch. The cystic odontoma in the maxillary sinus made the patient have the sings and symptoms of maxillary sinusitis. The cystic compound odontoma might be originated from the dental lamina of the missing upper right third molar. The 'V principle' of the upper jaw growth and the pneumatization process of the maxillary sinus could explain why the compound odontoma had peduncular shape and the location of odontoma was on the medial, superior to the normal position of the maxillary dental arch.

  14. Management of an impacted and transposed maxillary canine

    Directory of Open Access Journals (Sweden)

    Deepti A

    2010-03-01

    Full Text Available Maxillary canine-lateral incisor transposition is a relatively rare anomaly, with both dental and facial esthetic implications. This is a case report of a maxillary canine-lateral incisor transposition that was successfully treated by surgical-orthodontic treatment followed by esthetic reshaping of the involved teeth.

  15. Mass in right maxillary

    International Nuclear Information System (INIS)

    Marins, J.L.C.

    1988-01-01

    A radiological study in a patient with increasing of the volume in the naso-maxillary region was done. The proposed diagnosis were carcinomas, lymphomas, sarcomas, teeth cyst, granulomas, mycoses and other. (L.M.J.)

  16. Distraction rate and latency: factors in the outcome of paediatric maxillary distraction.

    Science.gov (United States)

    Higuera, Stephen; Cole, Patrick; Stephenson, J B; Hollier, Larry

    2009-12-01

    Over 50 years ago, current tenets of distraction osteogenesis were developed through work on the lower extremity; however, the application of these tenets in the paediatric craniofacial skeleton remains questionable. Prompted by recent concern that traditional aspects of distraction may be either outdated or wholly inapplicable to the paediatric maxilla, we retrospectively evaluated maxillary distraction protocol using a 24-h latency period in conjunction with a distraction rate of 2mm/day. Following maxillary advancement via a distraction protocol consisting of a 24-h latency period and a distraction rate of 2mm/day, seven consecutive paediatric cases were evaluated. Standard profile photos and cephalometric films taken preoperatively, at device removal and at 1-year follow-up were compared. With the sella as the point of registration, pre- and post-distraction films were superimposed on the sella-nasion plane. Sella-nasion-subspinale, the angle of convexity, the distance from incisal edges to the y-axis, and angulation of the upper incisor to the sella-nasion plane were analysed to evaluate hard-tissue changes. Patient age ranged from 3 to 14 years (mean=7.43 years). Maxillary distraction length averaged 11 mm (range=10-12 mm). Interval from device application to removal averaged 98 days (range=75-180 days). The interval of the active distraction ranged from 11 to 65 days (mean=24 days). From distraction completion to device removal averaged 85 days (range=60-150). Follow-up intervals ranged from 52 to 24 months (mean=34 months). All patients demonstrated substantial clinical advancement of the maxilla with correction of midfacial deficiencies. A single patient developed mild cellulitis at one skin-device interface; no other complications were noted. Cephalometric and clinical evaluations at 1 year post-distraction demonstrated stable results, and parental satisfaction was qualitatively high. The surgical dogma of lower-extremity distraction osteogenesis is not

  17. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface

    DEFF Research Database (Denmark)

    Gotfredsen, K; Karlsson, U

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate whether there was a difference between machined and TiO(2)-blasted implants regarding survival rate and marginal bone loss during a 5-year observation period. MATERIALS AND METHODS: A total of 133 implants (Astra Tech Dental Implants; Astra Tech...... AB, Mölndal, Sweden) were placed in 50 patients at 6 centers in 4 Scandinavian countries. Forty-eight implants were installed in the maxilla and 85 implants in the mandible. A randomization and a stratification were done, so that each fixed partial prosthesis was supported by at least 1 machined...... and 1 TiO(2)-blasted implant. The implant-supported fixed partial prostheses (ISFPP) were fabricated within 2 months after postoperative healing. A total of 52 ISFPP (17 maxillary, 35 mandibular) were inserted. The patients were clinically examined once a year for 5 years. At the annual follow...

  18. A Sequential Approach to Implant-Supported Overdentures.

    Science.gov (United States)

    Kosinski, Timothy

    2016-03-01

    Fabrication of implant-supported maxillary or mandibular overdentures can seem to be difficult procedures. Many things could go wrong and/or unnoticed until the fabrication has been completed. Implants must be correctly surgically placed in viable bone at the proper angulation and spacing within an arch. The type of attachment must be considered and future treatment of the appliance should be simple and efficient. The appliance must function not only initially but also for many years to come. The author has found the use of the GPS attachment to be an ideal tool to achieve the goals of retention and stability. Careful planning is the most important part of this process, and understanding the benefits and risks of creating overdentures should be well understood by the dentists. By sequentially planning and treating these types of cases, the patient is able to function reasonably during the stages of implant healing. The final prosthesis is created and remaining teeth that held the transitional appliance in place are remove on the day of final seating. This is an excellent simplified retentive system option for those patients who are anxious about losing their teeth, even those teeth that are diseased and ugly.

  19. Maxillary molar distalization with aligners in adult patients: a multicenter retrospective study

    Directory of Open Access Journals (Sweden)

    Serena Ravera

    2016-04-01

    Full Text Available Abstract Background The aim of the present study was to test the hypothesis that bodily maxillary molar distalization was not achievable in aligner orthodontics. Methods Forty lateral cephalograms obtained from 20 non-growing subjects (9 male, 11 female; average age 29.73 years (group S, who underwent bilateral distalization of their maxillary dentition with Invisalign aligners (Align Technology, Inc., San José, CA, USA, were considered for the study. Skeletal class I or class II malocclusion and a bilateral end-to-end class II molar relationship were the main inclusion criteria. Cephalograms were taken at two time points: (T0 pretreatment and (T2 post-treatment. Treatment changes were evaluated between the time points using 39 variables by means of paired t test. The level of significance was set at P < 0.05. Reproducibility of measurements was assessed by the intraclass correlation coefficient (ICC. Results The mean treatment time was 24.3 ± 4.2 months. At the post-treatment point, the first molar moved distally 2.25 mm without significant tipping (P = 0.27 and vertical movements (P = 0.43. The second molar distalization was 2.52 mm without significant tipping (P = 0.056 and vertical movements (P = 0.25. No significant movements were detected on the lower arch. SN^GoGn and SPP^GoGn angles showed no significant differences between pre- and post-treatment cephalograms (P = 0.22 and P = 0.85, respectively. Conclusions Aligner therapy in association with composite attachments and class II elastics can distalize maxillary first molars by 2.25 mm without significant tipping and vertical movements of the crown. No changes to the facial height were revealed.

  20. Comparison of Bone Resorption Rates after Intraoral Block Bone and Guided Bone Regeneration Augmentation for the Reconstruction of Horizontally Deficient Maxillary Alveolar Ridges

    Directory of Open Access Journals (Sweden)

    B. Alper Gultekin

    2016-01-01

    Full Text Available Purpose. Bone atrophy after tooth loss may leave insufficient bone for implant placement. We compared volumetric changes after autogenous ramus block bone grafting (RBG or guided bone regeneration (GBR in horizontally deficient maxilla before implant placement. Materials and Methods. In this retrospective study, volumetric changes at RBG or GBR graft sites were evaluated using cone-beam computed tomography. The primary outcome variable was the volumetric resorption rate. Secondary outcomes were bone gain, graft success, and implant insertion torque. Results. Twenty-four patients (28 grafted sites were included (GBR, 15; RBG, 13. One patient (RBG suffered mucosal dehiscence at the recipient site 6 weeks after surgery, which healed spontaneously. Mean volume reduction in the GBR and RBG groups was 12.48 ± 2.67% and 7.20 ± 1.40%, respectively. GBR resulted in significantly more bone resorption than RBG (P0.05. Conclusions. Both RBG and GBR hard-tissue augmentation techniques provide adequate bone graft volume and stability for implant insertion. However, GBR causes greater resorption at maxillary augmented sites than RBG, which clinicians should consider during treatment planning.

  1. Study of the relationship between the indication rod of stent on implant CT and the real path of implant fixture insertion considering residual ridge

    International Nuclear Information System (INIS)

    Kim, Do Hoon; Heo, Min Suk; Lee, Sam Sun; Oh, Sung Ook; Choi, Soon Chul; Choi, Hang Moon; Jeon, In Seong

    2003-01-01

    To assess the relationship between the direction of the indicating rod of the radiographic stent for ideal prosthetic design and the actual possible path of implant fixture placement when residual ridge resorption is considered. The study materials considered of 326 implant sites (male 214 cases and female 112 cases) from a total of 106 patients (male 65 patients and female 41 patients) who desired implant prostheses. Computed tomography of patients were taken and reformatted using ToothPix software. Bony defects, bony sclerosis, the change of the direction of indicating rod, and root proximity of the adjacent teeth were examined on the CT-derived images. The rate of the irregular crestal cortex was relatively high on premolar and molar area of maxilla. Mandibular molar area showed relatively high rate of focal sclerosis on the area of implant fixture insertion. The position of the including rods were relatively acceptable on the molar areas of both jaws. However, the position of the indicating rods should be shifted to buccal side with lingual rotation of the apical end on maxillary anterior teeth and premolar area. Clinically determined rod direction and position of the indicating rod for implant placement was not always acceptable for insertion according to the reformatted CT images. The pre-operative treatment plan for implant should be determined carefully, considering the state of the alveolar bone using the reformatted CT images.

  2. Maxillary canine impactions related to impacted central incisors: two case reports.

    Science.gov (United States)

    Bayram, Mehmet; Ozer, Mete; Sener, Ismail

    2007-09-01

    The purpose of this case report is to describe the combined surgical and orthodontic treatment of two cases with an impacted maxillary central incisor and canine in the same quadrant and to discuss the causal relationship between them. The most common causes of canine impactions are usually the result of one or more factors such as a long path of eruption, tooth size-arch length discrepancies, abnormal position of the tooth bud, prolonged retention or early loss of the deciduous canine, trauma, the presence of an alveolar cleft, ankylosis, cystic or neoplastic formation, dilaceration of the root, supernumerary teeth, and odontomas. Although impaction of the maxillary central incisor is almost as prevalent as impacted canines its etiology is different. The principal factors involved in causing the anomaly are supernumerary teeth, odontomas, and trauma. Case #1: A 10.5-year-old girl in the early mixed dentition stage presented with a chief complaint of the appearance of her anterior teeth. She had a Class I skeletal pattern and a history of trauma to the maxillary central incisors at age five with premature exfoliation. Radiographs revealed an impacted upper right central incisor in the region of the nasal floor, delayed eruption of the maxillary permanent central incisor, and the adjacent lateral incisor was inclined toward the edentulous space. Treatment was done in two stages consisting of surgical exposure and traction of the impacted central incisor and fixed orthodontic treatment. Case #2: An 11.5-year-old girl presented for orthodontic treatment with the chief complaint of an unerupted tooth and the appearance of her upper anterior teeth. She was in the late mixed dentition period with a Class III skeletal pattern along with an anterior cross-bite with some maxillary transverse deficiency. The maxillary right canine and central incisor were absent, but the maxillary right deciduous canine was still present. Treatment included arch expansion followed by

  3. Unilateral maxillary molar distalization with zygoma-gear appliance.

    Science.gov (United States)

    Kilkis, Dogan; Bayram, Mehmet; Celikoglu, Mevlut; Nur, Metin

    2012-08-01

    The aim of this study was to present the orthodontic treatment of a 15-year-old boy with a unilateral maxillary molar distalization system, called the zygoma-gear appliance. It consisted of a zygomatic anchorage miniplate, an inner bow, and a Sentalloy closed coil spring (GAC International, Bohemia, NY). A distalizing force of 350 g was used during the distalization period. The unilateral Class II malocclusion was corrected in 5 months with the zygoma-gear appliance. The maxillary left first molar showed distalization of 4 mm with an inclination of 3°. The maxillary premolars moved distally with the help of the transseptal fibers. In addition, there were slight decreases in overjet (-0.5 mm) and maxillary incisor inclination (-1°), indicating no anchorage loss from the zygoma-gear appliance. Preadjusted fixed appliances (0.022 × 0.028-in, MBT system; 3M Unitek, Monrovia, Calif) were placed in both arches to achieve leveling and alignment. After 14 months of unilateral distalization with the zygoma-gear appliance and fixed appliances, Class I molar and canine relationships were established with satisfactory interdigitation of the posterior teeth. Acceptable overjet and overbite were also achieved. This article shows that this new system, the zygoma-gear appliance, can be used for unilateral maxillary molar distalization without anchorage loss. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. Three-dimensional esthetic analysis in treatment planning for implant-supported fixed prosthesis in the edentulous maxilla: review of the esthetics literature.

    Science.gov (United States)

    Bidra, Avinash S

    2011-08-01

    Fixed implant-supported prosthesis for the edentulous maxilla has gained tremendous popularity over the years. Multiple prosthetic designs have been introduced in order to accommodate a gamut of clinical situations. Irrespective of the design, it is paramount that the esthetics imparted by the prosthesis be uncompromised. Though esthetics is subjective, a common ground exists where all its fundamental principles converge. This article reviews pertinent dental and facial esthetics literature for application of various esthetic concepts involved in diagnosis and treatment planning for an implant-supported fixed prosthesis in the edentulous maxilla. Three-dimensional esthetic analysis involves assessment of various esthetic parameters in superior-inferior, medial-lateral, and anterior-posterior dimensions. The impact of various esthetic parameters such as facial forms, facial profiles, maxillary teeth positions, maxillary teeth proportions, smile lines, lip support, gingival display, facial midline, dental midline, horizontal cant, and smile width are discussed in detail. © 2011 Wiley Periodicals, Inc.

  5. Modified hyrax splint for rapid maxillary expansion in esthetically concerned patients

    Directory of Open Access Journals (Sweden)

    Sarabjeet Singh Sandhu

    2015-01-01

    Full Text Available The orthodontic treatment of Class III malocclusion with a maxillary deficiency is often treated with maxillary protraction either with or without maxillary expansion. The routine procedure for rapid maxillary expansion includes banding on first premolars/first deciduous molars and the permanent first molars. However in some patients who are esthetically very conscious, banding of the first premolar would not be a good esthetic option. So for such circumstances we have designed a modified hyrax splint, which does not need the first premolars to be banded.

  6. The Effect of Alendronate on Various Graft Materials Used in Maxillary Sinus Augmentation: A Rabbit Study.

    Science.gov (United States)

    Ayranci, Ferhat; Gungormus, Metin; Omezli, Mehmet Melih; Gundogdu, Betul

    2015-12-01

    Increasing sinus pneumatization and the accompanying alveolar bone resorption complicate dental implant placement. This problem can be overcome today by raising the maxillary sinus floor with graft materials. Bisphosphonates are commonly used to accelerate the recovery of the graft materials and to prevent resorption. The purpose of this study is to investigate whether systemic administration of a bisphosphonate (alendronate) would improve new bone formation and reduce fibrous tissue formation over a 6-week follow-up in rabbits treated with two different grafting materials for maxillary sinus floor augmentation. This experimental animal study was conducted at the Experimental Medical Application and Research Center at Erzurum/ Turkey. Twelve New Zealand rabbits, each weighing between 2.7 and 3.3 kg, were used. Twenty-four maxillary sinus floor elevation operations were performed, two on each animal (n = 24). Each elevation was repaired with either deproteinized bovine bone (xenograft) or autogenous bone graft obtained from the iliac crest. Both groups were divided into 2 subgroups: saline-treated and alendronate-treated. All groups underwent the same surgical procedures and evaluation, and were sacrificed at the 6th postoperative week. Sinuses augmented with deproteinized bovine bone (xenograft) and autogenous bone graft were examined histopathologically and histomorphometrically. At 6 weeks, the bone area was significantly larger in the Xenograft-Alendronate group (33.0% ± 5.0%) than in the Xenograft-Saline group (20.8% ± 4.9%) and the bone area was significantly larger in the Autogenous-Alendronate group (43.3% ± 3.8%) than in the Autogenous-Saline group (37.5% ± 6.6%) (P = 0.001). The histomorphometric and histopathological results consistently showed that alendronate stimulated bone formation and reduced fibrous tissue formation in maxillary sinus augmentation grafts, especially in the deproteinized bovine bone group (xenograft). Alendronate may be

  7. CASE REPORT - Maxillary Herpes Zoster with Corneal Involvement ...

    African Journals Online (AJOL)

    Corneal involvement in maxillary herpes zoster is very rare. This report presents the case of a 32 years old 7 months pregnant para2+1 female, who presented with vesiculopapular rashes with hyperpigmented crusts over the maxillary area of the face on the left side with periocular oedema, conjunctivitis and mild punctate ...

  8. Fracture toughness of titanium–cement interfaces: effects of fibers and loading angles

    Directory of Open Access Journals (Sweden)

    Khandaker M

    2014-04-01

    Full Text Available Morshed Khandaker,1 Khatri Chhetri Utsaha,1 Tracy Morris21Department of Engineering and Physics, 2Department of Mathematics and Statistics, University of Central Oklahoma, Edmond, OK, USAAbstract: Ideal implant–cement or implant–bone interfaces are required for implant fixation and the filling of tissue defects created by disease. Micron- to nanosize osseointegrated features, such as surface roughness, fibers, porosity, and particles, have been fused with implants for improving the osseointegration of an implant with the host tissue in orthopedics and dentistry. The effects of fibers and loading angles on the interface fracture toughness of implant–cement specimens with and without fibers at the interface are not yet known. Such studies are important for the design of a long-lasting implant for orthopedic applications. The goal of this study was to improve the fracture toughness of an implant–cement interface by deposition of micron- to nanosize fibers on an implant surface. There were two objectives in the study: 1 to evaluate the influence of fibers on the fracture toughness of implant–cement interfaces with and without fibers at the interfaces, and 2 to evaluate the influence of loading angles on implant–cement interfaces with and without fibers at the interfaces. This study used titanium as the implant, poly(methyl methacrylate (PMMA as cement, and polycaprolactone (PCL as fiber materials. An electrospinning unit was fabricated for the deposition of PCL unidirectional fibers on titanium (Ti plates. The Evex tensile test stage was used to determine the interface fracture toughness (KC of Ti–PMMA with and without PCL fibers at 0°, 45°, and 90° loading angles, referred to in this article as tension, mixed, and shear tests. The study did not find any significant interaction between fiber and loading angles (P>0.05, although there was a significant difference in the KC means of Ti–PMMA samples for the loading angles (P<0

  9. Bilateral postoperative maxillary cysts after orthognathic surgery: A case report

    International Nuclear Information System (INIS)

    Lee, Jung Hye; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul

    2014-01-01

    Postoperative maxillary cysts are locally aggressive lesions, usually developing as delayed complications many years after radical antral surgery. This report describes a case of bilateral postoperative maxillary cysts following orthognathic surgery performed approximately 21 years previously. The patient complained of stinging pain on her right cheek. Radiographic examination revealed low-attenuation lesions on both maxillary sinuses with discontinuously corticated margins without distinct expansion or bone destruction. The cysts were enucleated with the removal of metal plates and screws for pain relief. Histopathological examination confirmed the diagnosis of postoperative maxillary cysts lined by ciliated, pseudostratified columnar cells. The patient has remained asymptomatic thus far, and there was no evidence of local recurrence at 21 months of postoperative follow-up.

  10. Bilateral postoperative maxillary cysts after orthognathic surgery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hye; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2014-12-15

    Postoperative maxillary cysts are locally aggressive lesions, usually developing as delayed complications many years after radical antral surgery. This report describes a case of bilateral postoperative maxillary cysts following orthognathic surgery performed approximately 21 years previously. The patient complained of stinging pain on her right cheek. Radiographic examination revealed low-attenuation lesions on both maxillary sinuses with discontinuously corticated margins without distinct expansion or bone destruction. The cysts were enucleated with the removal of metal plates and screws for pain relief. Histopathological examination confirmed the diagnosis of postoperative maxillary cysts lined by ciliated, pseudostratified columnar cells. The patient has remained asymptomatic thus far, and there was no evidence of local recurrence at 21 months of postoperative follow-up.

  11. Piezosurgery in Bone Augmentation Procedures Previous to Dental Implant Surgery: A Review of the Literature

    Science.gov (United States)

    Magrin, Gabriel Leonardo; Sigua-Rodriguez, Eder Alberto; Goulart, Douglas Rangel; Asprino, Luciana

    2015-01-01

    The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement. PMID:26966469

  12. Direct metal laser sintering (DMLS) of a customized titanium mesh for prosthetically guided bone regeneration of atrophic maxillary arches.

    Science.gov (United States)

    Ciocca, L; Fantini, M; De Crescenzio, F; Corinaldesi, G; Scotti, R

    2011-11-01

    This study describes a protocol for the direct manufacturing of a customized titanium mesh using CAD-CAM procedures and rapid prototyping to augment maxillary bone and minimize surgery when severe atrophy or post-oncological deformities are present. Titanium mesh and particulate autogenous plus bovine demineralised bone were planned for patient rehabilitation. Bone augmentation planning was performed using the pre-op CT data set in relation to the prosthetic demands, minimizing the bone volume to augment at the minimum necessary for implants. The containment mesh design was used to prototype the 0.6 mm thickness customized titanium mesh, by direct metal laser sintering. The levels of regenerated bone were calculated using the post-op CT data set, through comparison with the pre-op CT data set. The mean vertical height difference of the crestal bone was 2.57 mm, while the mean buccal-palatal dimension of thickness difference was 3.41 mm. All planned implants were positioned after an 8 month healing period using two-step implant surgery, and finally restored with a partial fixed prosthesis. We present a viable and reproducible method to determine the correct bone augmentation prior to implant placement and CAD-CAM to produce a customized direct laser-sintered titanium mesh that can be used for bone regeneration.

  13. Relationship between conductive hearing loss and maxillary constriction.

    Science.gov (United States)

    Peyvandi, A A; Jamilian, A; Moradi, E

    2014-09-01

    To evaluate the relationship between conductive hearing loss and maxillary constriction. A total of 120 people, aged from 7 to 40 years, who were referred to an audiologist when taking out health insurance or for school pre-registration check-up, were selected for this study. A total of 60 participants who had hearing threshold levels greater than 15 dB in both ears were chosen as the conductive hearing loss group. The remaining 60, with normal hearing thresholds of less than 15 dB, were used as the control group. All participants were referred to an orthodontic clinic. Participants who had a posterior crossbite and high palatal vault were considered to suffer from maxillary constriction. There were no significant differences between the sex ratios and mean ages of the groups. However, participants with conductive hearing loss were 3.5 times more likely than controls to suffer from maxillary constriction. Patients who suffer from conductive hearing loss are likely to show a maxillary abnormality when examined by an orthodontist.

  14. Influence of implant inclination associated with mandibular class I removable partial denture.

    Science.gov (United States)

    de Freitas Santos, Ciandrus Moraes; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos; de Moraes, Sandra Lúcia Dantas; Falcón-Antenucci, Rosse Mary

    2011-03-01

    The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.

  15. A comparison of profilometer and AutoCAD software techniques in evaluation of implant angulation in vitro.

    Science.gov (United States)

    Assunção, Wirley Gonçalves; Gomes, Erica Alves; Tabata, Lucas Fernando; Gennari-Filho, Humberto

    2008-01-01

    The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)--with a profilometer and AutoCAD software. Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P AutoCAD (89.95 degrees; P = .9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P = .0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.

  16. The stereognostic ability of natural dentitions versus implant-supported fixed prostheses or overdentures.

    Science.gov (United States)

    Jacobs, R; Bou Serhal, C; van Steenberghe, D

    1997-06-01

    A stereognostic ability test was performed in 60 patients. Forty patients were rehabilitated by means of osseointegrated implants. One group consisted of 20 patients with fixed prostheses on implants in both the upper and lower jaws. The other 20 patients had a maxillary denture while in the mandible an overdenture was retained by means of two implants connected by a bar. They were compared to a group of 20 subjects (controls) with a non-restored natural dentition. For the stereognostic ability test, subjects had to recognise ten different test pieces by manipulating them with two antagonistic incisor teeth, avoiding any contact with other oral structures. Both response time and percentage accuracy of recognition were evaluated. The present findings indicated that subjects with an overdenture on implants did not score significantly different from those with an implant-supported fixed prosthesis. In contrast, subjects with teeth had a significantly better stereognostic ability. The percentage of correct responses was 52% for overdentures, 56% for fixed prostheses on implants and 75% for natural dentitions. From these results, it could be concluded that the stereognostic ability is impaired in subjects rehabilitated with osseointegrated implants by about one-third to one-quarter compared to subjects with natural teeth.

  17. Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.

    Science.gov (United States)

    Sabir, Mohammad; Alam, Mohammad Nazish

    2015-06-01

    The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved.

  18. Perceptual Speech Assessment After Anterior Maxillary Distraction in Patients With Cleft Maxillary Hypoplasia.

    Science.gov (United States)

    Richardson, Sunil; Seelan, Nikkie S; Selvaraj, Dhivakar; Khandeparker, Rakshit V; Gnanamony, Sangeetha

    2016-06-01

    To assess speech outcomes after anterior maxillary distraction (AMD) in patients with cleft-related maxillary hypoplasia. Fifty-eight patients at least 10 years old with cleft-related maxillary hypoplasia were included in this study irrespective of gender, type of cleft lip and palate, and amount of required advancement. AMD was carried out in all patients using a tooth-borne palatal distractor by a single oral and maxillofacial surgeon. Perceptual speech assessment was performed by 2 speech language pathologists preoperatively, before placement of the distractor device, and 6 months postoperatively using the scoring system of Perkins et al (Plast Reconstr Surg 116:72, 2005); the system evaluates velopharyngeal insufficiency (VPI), resonance, nasal air emission, articulation errors, and intelligibility. The data obtained were tabulated and subjected to statistical analysis using Wilcoxon signed rank test. A P value less than .05 was considered significant. Eight patients were lost to follow-up. At 6-month follow-up, improvements of 62% (n = 31), 64% (n = 32), 50% (n = 25), 68% (n = 34), and 70% (n = 35) in VPI, resonance, nasal air emission, articulation, and intelligibility, respectively, were observed, with worsening of all parameters in 1 patient (2%). The results for all tested parameters were highly significant (P ≤ .001). AMD offers a substantial improvement in speech for all 5 parameters of perceptual speech assessment. Copyright © 2016 The American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Dental implants in patients with ectodermal dysplasia: A systematic review.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2018-05-21

    This study sought to assess the clinical outcome and survival rate of oral implants placed in individuals with ectodermal dysplasia (ED), based on previously published studies. An electronic search without time restrictions was undertaken in 5 databases (PubMed/Medline, Web of Science, ScienceDirect, J-Stage, Lilacs). Descriptive statistics, Kaplan Meier estimator and implant failure probability were calculated. 90 publications were included, reporting 228 ED patients that received 1472 implants (1392 conventional, 47 zygomatic, 33 mini-implants). Mean age of the patients was 20.2 ± 6.8 years (2-56). Patients had a mean of 3.2 ± 2.5 maxillary and 2.1 ± 2.6 mandibular permanent teeth (min-max, 0-14). Patients received a mean of 8.2 ± 3.8 implants (1-20). Most implants were placed in the third decade of life, 24.6% of the implants were placed in children (0-17 years of age). 1391 implants had information on follow-up (72 failures, 5.2%). The 20-year CSR was 84.6%. The probability of failure was 4.5% (95%CI 3.5%-5.6%, p < 0.001). Additional treatments performed were Le Fort I (99 implants, 20 patients, 3.5% failed), grafting (497 implants, 77 patients, 5.2% failed), distraction osteogenesis (79 implants, 16 patients, 10.1% failed). Mean follow-up was 42.9 ± 41.9 months (min-max, 2-240). Dental implants placed in ED patients, either infants or adults, present a high survival rate (20-year CSR 84.6%). Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Maxillary distraction osteogenesis in cleft lip and palate patients with skeletal anchorage.

    Science.gov (United States)

    Minami, Katsuhiro; Mori, Yoshihide; Tae-Geon, Kwon; Shimizu, Hidetaka; Ohtani, Miyuki; Yura, Yoshiaki

    2007-03-01

    Maxillary distraction osteogenesis with the rigid external distraction (RED) system has been used to treat cleft lip and palate (CLP) patients with severe maxillary hypoplasia. We introduce maxillary distraction osteogenesis for CLP patients with skeletal anchorage adapted on a stereolithographic model. Six maxillary deficiency CLP patients treated according to our CLP treatment protocol had undergone maxillary distraction osteogenesis. In all patients, computed tomography (CT) images were recorded preoperatively, and the data were transferred to a workstation. Three-dimensional skeletal structures were reconstructed with CT data sets, and a stereolithographic model was produced. On the stereolithographic model, miniplates were adapted to the surface of maxilla beside aperture piriforms. The operation performed involved a high Le Fort I osteotomy with pterygomaxillary disjunction. Miniplates were fixed to the maxillary segment with three or four screws and used for anchorage of the RED system. Retraction of the maxillary segment was initiated after 1 week. The accuracy of the stereolithographic models was enough to adapt the miniplates so that there was no need to readjust the plates during surgery. Postoperative cephalometric analysis showed that the direction of the retraction was almost parallel to the palatal plane, and dental compensation did not occur. We performed maxillary distraction osteogenesis with skeletal anchorage adapted on the stereolithographic models. Excellent esthetic outcome and skeletal advancement were achieved without dentoalveolar compensations.