WorldWideScience

Sample records for mattress pad test

  1. 16 CFR 1632.5 - Mattress pad test procedure.

    Science.gov (United States)

    2010-01-01

    ... 1632.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS... substrate. (b) Flame resistant mattress pads. The following additional requirements shall be applicable to mattress pads which contain a chemical fire retardant. (1) These mattress pads shall be tested in...

  2. 16 CFR 1632.31 - Mattresses/mattress pads-labeling, recordkeeping, guaranties and “one of a kind” exemption.

    Science.gov (United States)

    2010-01-01

    ...) Products intended for one time use (see § 1632.5(b)(1)(i)) are not subject to the requirements of... description of each mattress or mattress pad prototype with an assigned prototype identification number. (2) Test results and details of each prototype test performed in accordance with § 1632.4 or § 1632.5...

  3. 16 CFR 1632.4 - Mattress test procedure.

    Science.gov (United States)

    2010-01-01

    ... position at a reasonable height for making observations. (ii) If thin flexible mattresses or mattress pads... relative humidity measuring instrument, a thin rod, straight pins, a knife or scissors, and tongs are... (from water bottle), cut around the burning material with a knife or scissors and pull the material out...

  4. 16 CFR 1632.2 - Purpose, scope, and applicability.

    Science.gov (United States)

    2010-01-01

    ... resistance of a mattress prototype or a mattress pad prototype. Use of the tests in §§ 1632.6 and 1632.7 is... prototype designs of mattresses and mattress pads before the sale in commerce or the introduction in... of a mattress prototype or a mattress pad prototype. (b) Scope. (1) All mattresses, as defined in...

  5. The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair: Vertical or Horizontal Mattress?

    Science.gov (United States)

    Montanez, Anthony; Makarewich, Christopher A; Burks, Robert T; Henninger, Heath B

    2016-09-01

    Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Controlled laboratory study. Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the contralateral shoulder received a horizontal mattress. Specimens were mounted in a materials testing machine and tested in uniaxial tensile deformation for cyclic loading (500 cycles at 1 Hz to 1.0 MPa of effective stress), followed by failure testing carried out at a rate of 1 mm/s. Construct gapping and applied loads were monitored continuously throughout the testing. Vertical mattress sutures were placed in 5 right and 4 left shoulders. Peak cyclic gapping did not differ between vertical (mean ± SD, 2.8 ± 1.1 mm) and horizontal mattress specimens (3.0 ± 1.2 mm) (P = .684). Vertical mattress sutures failed at higher loads compared with horizontal mattress sutures (568.9 ± 140.3 vs 451.1 ± 174.3 N; P = .025); however, there was no significant difference in failure displacement (8.0 ± 1.6 vs 6.0 ± 2.1 mm; P = .092). Failure stiffness did not differ between the suture patterns (P = .204). In transosseous-equivalent rotator cuff repairs near the musculotendinous junction, a vertical mattress suture used as the medial stitch

  6. Pyroglyphid mites, xerophilic fungi and allergenic activity in dust from hospital mattresses.

    Science.gov (United States)

    v d Lustgraaf, B; Jorde, W

    1977-12-01

    Dust from mattresses of different composition and age was analysed for mites, xerophilic fungi and allergenic activity. The mites of the genus Demodex were the most abundant (58.2 per cent). Also pyroglyphid mites occurred commonly (36.6 per cent). Pyroglyphid mites were present in small numbers (mean: 1 specimen/0.2 g of dust) in 12 out of the 17 older polyester-foam mattresses. The 11 cotton-horsechair mattresses and the newly used polyester-foam mattresses (three tested) were without them. The dust from the cotton-horsehair mattresses had a significantly higher allergenic activity than from those of polyester-foam. Xerophilic fungi were isolated in three out of 31 mattresses. The species isolated belonged to the genus Aspergillus and Eurotium. E. repens occurred most frequently. Disinfection of mattresses was suggested to have a negative influence on the occurrence of mites and fungi.

  7. 75 FR 72944 - Third Party Testing for Certain Children's Products; Mattresses, Mattress Pads, and/or Mattress...

    Science.gov (United States)

    2010-11-29

    ...: Revisions to Terms of Acceptance of Children's Product Certifications Based on Third Party Conformity... under which it will accept certifications for children's products based on third party conformity..., requires that certification be based on testing of sufficient samples of the product, or samples that are...

  8. 75 FR 51020 - Third Party Testing for Certain Children's Products; Mattresses, Mattress Pads, and/or Mattress...

    Science.gov (United States)

    2010-08-18

    ... Standardization (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... body that was ISO/IEC 17025 accredited by an ILAC-MRA member at the time of the test. For firewalled...

  9. A Comparison of Cervical Spine Motion After Immobilization With a Traditional Spine Board and Full-Body Vacuum-Mattress Splint.

    Science.gov (United States)

    Etier, Brian E; Norte, Grant E; Gleason, Megan M; Richter, Dustin L; Pugh, Kelli F; Thomson, Keith B; Slater, Lindsay V; Hart, Joe M; Brockmeier, Stephen F; Diduch, David R

    2017-12-01

    The National Athletic Trainers' Association (NATA) advocates for cervical spine immobilization on a rigid board or vacuum splint and for removal of athletic equipment before transfer to an emergency medical facility. To (1) compare triplanar cervical spine motion using motion capture between a traditional rigid spine board and a full-body vacuum splint in equipped and unequipped athletes, (2) assess cervical spine motion during the removal of a football helmet and shoulder pads, and (3) evaluate the effect of body mass on cervical spine motion. Controlled laboratory study. Twenty healthy male participants volunteered for this study to examine the influence of immobilization type and presence of equipment on triplanar angular cervical spine motion. Three-dimensional cervical spine kinematics was measured using an electromagnetic motion analysis system. Independent variables included testing condition (static lift and hold, 30° tilt, transfer, equipment removal), immobilization type (rigid, vacuum-mattress), and equipment (on, off). Peak sagittal-, frontal-, and transverse-plane angular motions were the primary outcome measures of interest. Subjective ratings of comfort and security did not differ between immobilization types ( P > .05). Motion between the rigid board and vacuum splint did not differ by more than 2° under any testing condition, either with or without equipment. In removing equipment, the mean peak motion ranged from 12.5° to 14.0° for the rigid spine board and from 11.4° to 15.4° for the vacuum-mattress splint, and more transverse-plane motion occurred when using the vacuum-mattress splint compared with the rigid spine board (mean difference, 0.14 deg/s [95% CI, 0.05-0.23 deg/s]; P = .002). In patients weighing more than 250 lb, the rigid board provided less motion in the frontal plane ( P = .027) and sagittal plane ( P = .030) during the tilt condition and transfer condition, respectively. The current study confirms similar motion in the

  10. 21 CFR 880.5560 - Temperature regulated water mattress.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temperature regulated water mattress. 880.5560... Therapeutic Devices § 880.5560 Temperature regulated water mattress. (a) Identification. A temperature regulated water mattress is a device intended for medical purposes that consists of a mattress of suitable...

  11. Esprit HR mattress cover in pressure ulcer prevention.

    Science.gov (United States)

    Khoulowa, J

    Modern mattresses provide soft dense foam, which permits the redistribution of pressure on the patient over a wider area - away from bony prominences where pressure ulcers usually occur. The material used in producing multistretch covers for the new mattresses had a tendency to delaminate as a result of a combination of heat, moisture and inappropriate cleansing techniques causing the water barriers to fall. In partnership with York Health NHS Trust and the material manufacturer, STM Healthcare produced a mattress cover (Esprit HR) which was able to withstand higher pressure from heat and moisture and greatly extended the life expectancy of the Esprit HR mattress.

  12. The effect of human-mattress interface's temperature on perceived thermal comfort.

    Science.gov (United States)

    Califano, R; Naddeo, A; Vink, P

    2017-01-01

    In recent years, methods that allow for an objective evaluation of perceived comfort, in terms of postural, physiological, cognitive and environmental comfort, have received a great deal of attention from researchers. This paper focuses on one of the factors that influences physiological comfort perception: the temperature difference between users and the objects with which they interact. The first aim is to create a measuring system that does not affect the perceived comfort during the temperatures' acquisition. The main aim is to evaluate how the temperature at the human-mattress interface can affect the level of perceived comfort. A foam mattress has been used for testing in order to take into account the entire back part of the human body. The temperature at the interface was registered by fourteen 100 Ohm Platinum RTDs (Resistance Temperature Detectors) placed on the mattress under the trunk, the shoulders, the buttocks, the legs, the thighs, the arms and the forearms of the test subject. 29 subjects participated in a comfort test in a humidity controlled environment. The test protocol involved: dress-code, anthropometric-based positioning on mattress, environment temperature measuring and an acclimatization time before the test. At the end of each test, each of the test subject's thermal sensations and the level of comfort perception were evaluated using the ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) scale. The data analyses concerned, in the first instance, correlations between the temperature at the interface and comfort levels of the different parts of the body. Then the same analyses were performed independently of the body parts being considered. The results demonstrated that there was no strong correlation among the studied variables and that the total increase of temperature at interface is associated with a reduction in comfort. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. The provision of therapy mattresses for pressure ulcer prevention.

    Science.gov (United States)

    Pagnamenta, Fania

    2017-03-23

    Preventing pressure ulcers is complex and involves skin care, the provision of therapy mattresses, repositioning, the management of incontinence and adequate nutritional support. This article describes a model of therapy mattress provision that is based on non-powered products. Evaluating the efficiency of this model is challenging, due to the complexities of care, but Safety Thermometer data and incidents reports offer reassurance that non-powered therapy mattresses can provide adequate pressure ulcer prevention. Therapy mattress provision is only one of the five interventions and these are described in details to give readers a fuller picture of the model used at the author's trust.

  14. Sterilization using ozone-ion gas sterilization using ozone-ion gas for mattresses used by the elderly; Ozone ion kunjoho ni kansuru kenkyu. Ozone ion kunjoho no zaitaku kaigoyo mattress mekkin eno oyo

    Energy Technology Data Exchange (ETDEWEB)

    Mikami, H.; Suzuki, A.; Hamasaki, H. [Shinryo Corp., Tokyo (Japan); Ishikawa, S.; Miyata, M.; Nanba, T. [Kitasato Univ., Tokyo (Japan); Sueyoshi, K. [Mitsubishi Research Institute Inc., Tokyo (Japan)

    1999-05-25

    The new generation of Japanese is facing an aging society: the number of young people is decreasing dramatically, while the number of elderly is increasing. Consequently, care for the elderly has become a big problem. One particular problem area we`ve investigated is the use of unclean mattresses by the bedridden elderly. These mattresses provide an all too excellent environments for the growth of microbes. We measured the density of microbes on the cover of mattresses at 775cfu/cm{sup 2} and in the bed filling at 136cfu/g. The dominant species of microbes were MRSA and Bacillus. We used MRSA, Bacillus subtilis and Escherichia coli as biological indicators and tested whether our system using ozone-ion fumigants was applicable for sterilization of mattresses. The survival ratio of MRSA were 10{sup -8} {approx} 10{sup -9}, 10{sup -7} {approx} 10{sup -8} for B. subtilis and below 10{sup -8} for E. coli. These experiments made it clear that our system is applicable for sterilization of the mattresses used by bedfast elderly. (author)

  15. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  16. Validation of an iPad test of letter contrast sensitivity.

    Science.gov (United States)

    Kollbaum, Pete S; Jansen, Meredith E; Kollbaum, Elli J; Bullimore, Mark A

    2014-03-01

    An iPad-based letter contrast sensitivity test was developed (ridgevue.com) consisting of two letters on each page of an iBook. The contrast decreases from 80% (logCS = 0.1) to 0.5% (logCS = 2.3) by 0.1 log units per page. The test was compared to the Pelli-Robson Test and the Freiburg Acuity and Contrast Test. Twenty normally sighted subjects and 20 low-vision subjects were tested monocularly at 1 m using each test wearing their habitual correction. After a 5-minute break, subjects were retested with each test in reverse order. Two different letter charts were used for both the Pelli-Robson and iPad tests, and the order of testing was varied systematically. For the Freiburg test, the target was a variable contrast Landolt C presented at eight possible orientations and used a 30-trial Best PEST procedure. Repeatability and agreement were assessed by determining the 95% limits of agreement (LoA) ± 1.96 SD of the differences between administrations or tests. All three tests showed good repeatability in terms of the 95% LoA: iPad = ± 0.19, Pelli-Robson = ± 0.19, and Freiburg = ± 0.15. The iPad test showed good agreement with the Freiburg test with similar mean (± SD) logCS (iPad = 1.98 ± 0.11, Freiburg = 1.96 ± 0.06) and with narrow 95% LoA (± 0.24), but the Pelli-Robson test gave significantly lower values (1.65 ± 0.04). Low-vision subjects had slightly poorer repeatability (iPad = ± 0.24, Pelli-Robson = ± 0.23, Freiburg = ± 0.21). Agreement between the iPad and Freiburg tests was good (iPad = 1.45 ± 0.40, Freiburg = 1.54 ± 0.37), but the Pelli-Robson test gave significantly lower values (1.30 ± 0.30). The iPad test showed similar repeatability and may be a rapid and convenient alternative to some existing measures. The Pelli-Robson test gave lower values than the other tests.

  17. Research on the relationship between the structural properties of bedding layer in spring mattress and sleep quality.

    Science.gov (United States)

    Shen, Liming; Chen, Yu-xia; Guo, Yong; Zhong, ShiLu; Fang, Fei; Zhao, Jing; Hu, Tian-Yi

    2012-01-01

    Mattress, as a sleep platform, its types and physical properties has an important effect on sleep quality and rest efficiency. In this paper, by subjective evaluations, analysis of sleeping behaviors and tests of depth of sleep, the relationship between characteristics of the bedding materials, the structure of mattress, sleep quality and sleep behaviors were studied. The results showed that: (1) Characteristics of the bedding materials and structure of spring mattress had a remarkable effect on sleep behaviors and sleep quality. An optimum combination of the bedding materials, the structure of mattress and its core could improve the overall comfort of mattress, thereby improving the depth of sleep and sleep quality. (2) Sleep behaviors had a close relationship with sleeping postures and sleep habits. The characteristics of sleep behaviors vary from person to person.

  18. Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.

    Science.gov (United States)

    Rimstad, Liv; Larsen, Elsa Skjønhaug; Schiøtz, Hjalmar A; Kulseng-Hanssen, Sigurd

    2014-09-01

    The aim of the study was to test the ability of pad stress tests with increasing load (supine, jumping on the floor, and jumping on a trampoline) to document stress incontinence in subjectively stress incontinent women. In this prospective study 147 subjectively stress and mixed incontinent women performed consecutively the three pad stress tests with a bladder volume of 300 ml. Nineteen women performed a second trampoline pad stress test to test repeatability of the test. Nine continent women performed a trampoline pad stress test in order to determine if subjectively continent women would leak during the test. Seventy-two women (49%) leaked during the supine, 136 (93%) leaked during the jumping, and 146 (99%) leaked during the trampoline pad stress test. The differences between pad stress tests were significant with P trampoline pad stress tests was high at 0.8. None of the nine continent women leaked during the trampoline pad stress test. The supine pad stress test has low sensitivity and is therefore often falsely negative. The jumping pad stress test is a simple test to perform and is satisfactory for everyday use. Subjectively stress incontinent women who do not leak during the jumping pad stress test may perform a trampoline pad stress test to document stress incontinence. The trampoline pad stress test is also simple to perform and detected leakage in 91% of the women who did not leak during the jumping pad stress test. © 2013 Wiley Periodicals, Inc.

  19. Structural response testing of thermal barrier load-bearing ceramic pads

    International Nuclear Information System (INIS)

    Black, W.E.; Luci, R.K.; Pickering, J.L.; Oland, G.B.

    1983-01-01

    A load bearing insulating structure for use in a HTGR was investigated. The structure was composed of dense ceramic materials in the form of circular pads arranged in a stack. Specifically, the test program was structured to investigate the isolation effectiveness of interface materials placed between the ceramic pads to reduce the effectiveness of mechanically induced loads. The tests were conducted at room temperature using tapered loading platens on single ceramic pads. Seventeen alumina specimens, representing two types of material and two thicknesses, were tested. Three interface material thicknesses were introduced using silica cloth and graphite foil. Pre and post test nondestructive examinations were conducted in an effort to identify potential damage-inducing anomalies in the ceramic pads. A total of 62 tests was conducted with all specimens eventually loaded to failure. (orig./HP)

  20. Tests of MVD prototype pad detector with a β- source

    International Nuclear Information System (INIS)

    Yeol Kim, Sang; Gook Kim, Young; Su Ryu, Sang; Hwan Kang, Ju; Simon-Gillo, Jehanne; Sullivan, John P.; Heck, Hubert W. van; Xu Guanghua

    1999-01-01

    The MVD group has been testing two versions of silicon pad detectors. One design uses a single metal layer for readout trace routing. The second type uses two layers of metal, allowing for greatly simplified signal routing. However, because the readout traces for the pads pass over the other pads in the same column (separated by an oxide layer), the double-metal design introduces crosstalk into the system. A simple test stand using a 90 Sr β - source with scintillator triggers was made to estimate the crosstalk. The crosstalk between pads in the same column of the pad detector was 1.6-3.1%. The values measured between pads in different columns were very close to zero. The measured crosstalk was below our maximum allowed value of 7.8%

  1. Structural response testing of thermal barrier load bearing ceramic pads

    International Nuclear Information System (INIS)

    Pickering, J.L.; Black, W.E.; Luci, R.K.; Oland, C.B.

    1983-01-01

    A load-bearing insulating structure for use in a high-temperature gas-cooled reactor (HTGR) was investigated. The structure was composed of dense ceramic materials in the form of circular pads arranged in a stack. Specifically, the test program was structured to investigate the isolation effectiveness of interface materials placed between the ceramic pads to reduce the effectiveness of mechanically induced loads. The tests were conducted at room temperature using tapered loading platens on single ceramic pads. Seventeen alumina specimens, representing two types of material and two thicknesses, were tested. Three interface material thicknesses were introduced using silica cloth and graphite foil. Pre- and post-test nondestructive examinations were conducted in an effort to identify potential damage-inducing anomalies in the ceramic pads. A total of 62 tests was conducted with all specimens eventually loaded to failure

  2. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Science.gov (United States)

    2010-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  3. Conceptontwerp nieuwe slaapmatten (Concept Design of Sleeping Mattresses)

    Science.gov (United States)

    2008-11-01

    Datum november 2008 Auteur (s) drs. P.A. Reffeltrath ing. M.G. Brandsma M.G.M. Weghorst Rubricering rapport Ongerubriceerd TK9 TNO-rapport...slaapmatten in combinatie met de gegevens van objectieve metingen. In theorie maakt het conceptontwerp het mogelijk om tegen minder gewicht en pakvolume...making a mattress that is lighter, has less packing volume, is more comfortable and more durable than the currently available mattresses. In theory

  4. The accumulation of dust mite allergens on mattresses made of different kinds of materials.

    Science.gov (United States)

    Visitsunthorn, Nualanong; Chirdjirapong, Varakorn; Pootong, Visanu; Jirapongsananuruk, Orathai; Pacharn, Punchama; Weeravejsukit, Sirirat; Mahakittikun, Vanna; Vichyanond, Pakit

    2010-01-01

    Different mattress materials may affect the accumulation of allergens. To compare the amount of group 1 dust mite allergens (Der p1 + Der f1) on mattresses made of different kinds of materials before and after use. Sixty new mattresses made of kapok, synthetic fiber, coconut fiber and sponge-like polyurethane, were placed in the house officers' dormitory at Siriraj hospital, Thailand. The dust samples were collected before (0), 1, 2, 3, 6, 9 and 12 months after the mattresses were used. Group 1 dust mite allergens were analyzed using two-site monoclonal antibody ELISA. Der f1 made up 86.7 % of group 1 allergens found in the matress dust. After the 2nd month, only the mean level in sponge-like polyurethane mattress was under 2 microg/g dust (sensitized level). At the 6th month, the mean levels were 13.1 in coconut, 21.7 in kapok and 17.3 microg/g dust in synthetic fiber, all of which were more than 10 microg/g dust (symptomatic level). At the 9th month, the level in sponge-like polyurethane mattress was increased to 11.2 microg/g. At 12th month the level in coconut fiber, sponge-like polyurethane synthetic fiber and kapok mattresses were 20.2, 22.4, 28.9 and 32.2 microg/g dust respectively. The accumulation rate in kapok and synthetic mattresses was significantly higher than coconut and sponge-like polyurethane mattresses. The mean level of group 1 mite allergens exceeded 10 microg/g dust after the 6th month of use in coconut fiber, kapok and synthetic fiber and at the 9th month in sponge-like polyurethane mattress.

  5. TID Test Results for 4th Generation iPad(TradeMark)

    Science.gov (United States)

    Guertin, S. M.; Allen, G. R.; McClure, S. S.; LaBel, K. A.

    2013-01-01

    TID testing of 4th generation iPads is reported. Of iPad subsystems, results indicate that the charging circuitry and display drivers fail at lowest TID levels. Details of construction are investigated for additional testing of components.

  6. A hinged-pad test structure for sliding friction measurement in micromachining

    Energy Technology Data Exchange (ETDEWEB)

    Boer, M.P. de; Redmond, J.M.; Michalske, T.A.

    1998-08-01

    The authors describe the design, modeling, fabrication and initial testing of a new test structure for friction measurement in MEMS. The device consists of a cantilevered forked beam and a friction pad attached via a hinge. Compared to previous test structures, the proposed structure can measure friction over much larger pressure ranges, yet occupies one hundred times less area. The placement of the hinge is crucial to obtaining a well-known and constant pressure distribution in the device. Static deflections on the device were measured and modeled numerically, Preliminary results indicate that friction pad slip is sensitive to friction pad normal force.

  7. Warming preterm infants in the delivery room: polyethylene bags, exothermic mattresses or both?

    Science.gov (United States)

    McCarthy, Lisa K; O'Donnell, Colm P F

    2011-12-01

    To compare the admission temperature of infants treated with polyethylene bags alone to infants treated with exothermic mattresses in addition to bags in the delivery room. We prospectively studied infants born at bags at birth. Some infants were also placed on mattresses. Admission axillary temperatures were measured in all infants on admission to the neonatal intensive care. We compared the temperatures of infants treated with bags alone to those treated with mattresses and bags. We studied 43 infants: 15 were treated with bags while 28 were treated with a bag and mattress. Mean admission temperature was similar between the groups. Hypothermia and hyperthermia occurred more frequently in infants treated with a bag and mattress, and more infants treated with a bag had admission temperatures 36.5-37.5°C. The use of exothermic mattresses in addition to polyethylene bags, particularly in younger, smaller newborns, may result in more hypothermia and hyperthermia on admission. A randomised controlled trial is necessary to determine which strategy results in more infants having admission temperatures in the normal range. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.

  8. Safety test No. S-6, launch pad abort sequential test Phase II: solid propellant fire

    International Nuclear Information System (INIS)

    Snow, E.C.

    1975-08-01

    In preparation for the Lincoln Laboratory's LES 8/9 space mission, a series of tests was performed to evaluate the nuclear safety capability of the Multi-Hundred Watt (MHW) Radioisotope Thermoelectric Generator (RTG) to be used to supply power for the satellite. One such safety test is Test No. S-6, Launch Pad Abort Sequential Test. The objective of this test was to subject the RTG and its components to the sequential environments characteristic of a catastrophic launch pad accident to evaluate their capability to contain the 238 PuO 2 fuel. This sequence of environments was to have consisted of the blast overpressure and fragments, followed by the fireball, low velocity impact on the launch pad, and solid propellant fire. The blast overpressure and fragments were subsequently eliminated from this sequence. The procedures and results of Phase II of Test S-6, Solid Propellant Fire are presented. In this phase of the test, a simulant Fuel Sphere Assembly (FSA) and a mockup of a damaged Heat Source Assembly (HSA) were subjected to single proximity solid propellant fires of approximately 10-min duration. Steel was introduced into both tests to simulate the effects of launch pad debris and the solid rocket motor (SRM) casing that might be present in the fire zone. (TFD)

  9. The Impact of Legislation on Gas Can- and Mattress-Related Burn Injuries.

    Science.gov (United States)

    Kellogg, Levi; Butcher, Brandon; Peek-Asa, Corinne; Wibbenmeyer, Lucy

    2018-01-01

    Burn prevention program success requires thorough evaluation of intervention outcomes. The impact of 2 engineering-specific burn prevention regulations, the Children's Gasoline Burn Prevention Act and the Standard for the Flammability of Mattress Sets, will be assessed. Records from 1997 to 2015 within the Consumer Product Safety Commission's (CPSC) National Electronic Injury Surveillance System (NEISS) were reviewed. After identifying gas can- and mattress-involved burn injuries, injury incidence was estimated by utilizing survey sampling weights associated with each record. Logistic regression, incorporating estimated injury incidence and adjusting for gender and age, was performed to test for change in injury risk following these regulations. Within NEISS, there were 493 burns involving gas cans, yielding an estimated 19,339 injuries (95% confidence interval [CI], 15,781-22,896) during the 19-year study period. The odds of a gas can burn injury after legislation decreased by 67% for children younger than 5 years (odds ratio [OR], 0.33; 95% CI, 0.16-0.66; P = 0.0018). There was no significant change in risk for persons 5 years and older (OR, 1.07; 95% CI, 0.80-1.41; P = 0.66). During the same time, there were 219 NEISS burns involving mattresses, yielding an estimated 6864 injuries (95% CI, 5071-8658). The odds of a mattress burn injury following legislation enactment decreased by 31% for all ages (OR, 0.69; 95% CI, 0.51-0.94; P = 0.02). Both regulations decreased the odds of injury in their target populations. This study demonstrates that passive interventions involving engineering standards remain a powerful tool for burn prevention and should be the focus of future efforts to improve burn care.

  10. Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair.

    Science.gov (United States)

    Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q

    2014-03-01

    We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.

  11. Does a foamy-block mattress system prevent pressure sores ? A prospective randomised clinical trial in 1729 patients.

    Science.gov (United States)

    Berthe, J V; Bustillo, A; Mélot, C; de Fontaine, S

    2007-01-01

    Pressure ulcers are a frequent complication of bed rest. The development of an efficient and low cost pressure relieving system for the prevention of bed-sores would be of considerable hospital health and economic interest. Our study was designed to determine the effectiveness in pressure-sore prevention of an interface pressure-decreasing mattress, the Kliniplot mattress, used in our institution since 1978. In a prospective randomised controlled 7-month clinical trial we compared the Kliniplot mattress with our standard hospital mattress in 1729 patients admitted to medical and surgical departments (neurology, cardiology, oncology-haematology, neurosurgery, thoracic surgery and orthopaedic surgery). Two groups (Klinipot mattress and standard hospital mattress) were monitored for the prevention of pressure sores. The patients were evaluated on a daily basis from their admission until the eventual occurrence of a bed-sore. Patients' characteristics and pressure-sore risk factors were similar at the baseline in both groups. Patients presenting with a pressure sore at the time of admission were excluded. Forty-two of the 1729 patients (2.4%) who entered the study developed at least one pressure sore. Twenty-one of the 657 patients (3.2%) nursed on the Kliniplot mattress, and 21 of the 1072 patients (1.9%) on the standard mattress developed bed-sores (p = 0.154). The median time for the occurrence of pressure sores was 31 days (range 6-87) with the Kliniplot mattress and 18 days (range 2 to 38) with the standard mattress (p sores using the modified Ek's scale were no different at the baseline between both groups (p = 0.764). The severity of the pressure sores was no different between both groups (p = 0.918). Our results show that the occurrence of pressure sores is not reduced but is delayed when patients are nursed on a Kliniplot pressure-decreasing mattress.

  12. Evaluation of free-stall mattress bedding treatments to reduce mastitis bacterial growth

    Energy Technology Data Exchange (ETDEWEB)

    Kristula, M A; Dou, Z; Toth, J D; Smith, B I; Harvey, N; Sabo, M [University of Penn, Kennett Square, PA (United States)

    2008-05-15

    Bacterial counts were compared in free-stall mattresses and teat ends exposed to 5 treatments in a factorial study design on 1 dairy farm. Mattresses in five 30-cow groups were subjected to 1 of 5 bedding treatments every other day: 0.5 kg of hydrated limestone, 120 mL of commercial acidic conditioner, 1 kg of coal fly ash, 1 kg of kiln-dried wood shavings, and control (no bedding). Counts of coliforms, Klebsiella spp., Escherichia coli, and Streptococcus spp. were lowest on mattresses bedded with lime. Mattresses bedded with the commercial acidic conditioner had the next lowest counts for coliforms, Klebsiella spp., and Streptococcus spp. Wood shavings and the no-bedding control had the highest counts for coliform and Klebsiella spp. Compared with wood shavings or control, fly ash reduced the counts of coliforms, whereas for the other 3 bacterial groups, the reduction was not always significant. Streptococcus spp. counts were greatest in the control group and did not differ among the shavings and fly ash groups. Teat swab results indicated that hydrated lime was the only bedding treatment that significantly decreased the counts of both coliforms and Klebsiella spp. There were no differences in Streptococcus spp. numbers on the teats between any of the bedding treatments. Bacterial populations grew steadily on mattresses and were generally higher at 36 to 48 h than at 12 to 24 h, whereas bacterial populations on teats grew rapidly by 12 h and then remained constant. Hydrated lime was the only treatment that significantly reduced bacterial counts on both mattresses and teat ends, but it caused some skin irritation.

  13. Bedding on geotextile mattresses: how much is needed to improve cow comfort?

    Science.gov (United States)

    Tucker, C B; Weary, D M

    2004-09-01

    The objective of our study was to evaluate how the amount of sawdust bedding on mattresses affects dairy cattle behavior and preferences. Eleven nonlactating, multiparous cows were housed individually in pens with access to 3 free stalls. Each stall was fitted with a geotextile mattress covered with either 0, 1, or 7.5 kg of kiln-dried sawdust. The experiment began with 7 d of acclimatization to all 3 stalls. Cows were then allowed access to only 1 of the 3 stalls at a time, each for 3 d (restriction phase). At the end of this restriction phase, cows were allowed free access to all 3 stalls for 3 d (free-choice phase). Time spent lying and the number of lying bouts increased significantly with the amount of bedding, from 12.3 +/- 0.53 h lying and 8.5 +/- 0.62 bouts per 24 h on bare mattresses to 13.8 +/- 0.53 h lying and 10.0 +/- 0.62 bouts per 24 h on mattresses with 7.5 kg of sawdust. In addition, the animals spent less time standing with only the front hooves in the stalls when more sawdust was present. When allowed free access to all 3 options, all 11 animals spent a majority of their time lying and standing in the 7.5-kg option. In conclusion, cows preferred mattresses bedded with 7.5 kg of sawdust, on which they spent more time lying down and less time standing with only the front hooves in stalls. These results indicate that more sawdust bedding improves cow comfort in stalls with geotextile mattresses.

  14. Does It Matter Whether One Takes a Test on an iPad or a Desktop Computer?

    Science.gov (United States)

    Ling, Guangming

    2016-01-01

    To investigate possible iPad related mode effect, we tested 403 8th graders in Indiana, Maryland, and New Jersey under three mode conditions through random assignment: a desktop computer, an iPad alone, and an iPad with an external keyboard. All students had used an iPad or computer for six months or longer. The 2-hour test included reading, math,…

  15. Manual cleaning of hospital mattresses: an observational study comparing high- and low-resource settings.

    Science.gov (United States)

    Hopman, J; Hakizimana, B; Meintjes, W A J; Nillessen, M; de Both, E; Voss, A; Mehtar, S

    2016-01-01

    Hospital-associated infections (HAIs) are more frequently encountered in low- than in high-resource settings. There is a need to identify and implement feasible and sustainable approaches to strengthen HAI prevention in low-resource settings. To evaluate the biological contamination of routinely cleaned mattresses in both high- and low-resource settings. In this two-stage observational study, routine manual bed cleaning was evaluated at two university hospitals using adenosine triphosphate (ATP). Standardized training of cleaning personnel was achieved in both high- and low-resource settings. Qualitative analysis of the cleaning process was performed to identify predictors of cleaning outcome in low-resource settings. Mattresses in low-resource settings were highly contaminated prior to cleaning. Cleaning significantly reduced biological contamination of mattresses in low-resource settings (P cleaning in both the high- and low-resource settings seemed comparable. Cleaning with appropriate type of cleaning materials reduced the contamination of mattresses adequately. Predictors for mattresses that remained contaminated in a low-resource setting included: type of product used, type of ward, training, and the level of contamination prior to cleaning. In low-resource settings mattresses were highly contaminated as noted by ATP levels. Routine manual cleaning by trained staff can be as effective in a low-resource setting as in a high-resource setting. We recommend a multi-modal cleaning strategy that consists of training of domestic services staff, availability of adequate time to clean beds between patients, and application of the correct type of cleaning products. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Use of backboard and deflation improve quality of chest compression when cardiopulmonary resuscitation is performed on a typical air inflated mattress configuration.

    Science.gov (United States)

    Oh, Jaehoon; Kang, Hyunggoo; Chee, Youngjoon; Lim, Taeho; Song, Yeongtak; Cho, Youngsuk; Je, Sangmo

    2013-02-01

    No study has examined the effectiveness of backboards and air deflation for achieving adequate chest compression (CC) depth on air mattresses with the typical configurations seen in intensive care units. To determine this efficacy, we measured mattress compression depth (MCD, mm) on these surfaces using dual accelerometers. Eight cardiopulmonary resuscitation providers performed CCs on manikins lying on 4 different surfaces using a visual feedback system. The surfaces were as follows: A, a bed frame; B, a deflated air mattress placed on top of a foam mattress laid on a bed frame; C, a typical air mattress configuration with an inflated air mattress placed on a foam mattress laid on a bed frame; and D, C with a backboard. Deflation of the air mattress decreased MCD significantly (B; 14.74 ± 1.36 vs C; 30.16 ± 3.96, P deflation of the air mattress decreased MCD more than use of a backboard (B; 14.74 ± 1.36 vs D; 25.46 ± 2.89, P = 0.002). The use of a both a backboard and a deflated air mattress in this configuration reduces MCD and thus helps achieve accurate CC depth during cardiopulmonary resuscitation.

  17. Agreement analysis comparing iPad LCVA and Sloan testing in multiple sclerosis patients.

    Science.gov (United States)

    Sattarnezhad, Neda; Farrow, Samantha; Kimbrough, Dorlan; Glanz, Bonnie; Healy, Brian; Chitnis, Tanuja

    2017-06-01

    Visual symptoms are common in multiple sclerosis (MS). Low-contrast visual acuity (LCVA) testing using Sloan charts has demonstrated increased sensitivity for visual deficits compared to high-contrast acuity testing. Computerized testing of visual acuity may facilitate use in the clinic setting. To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients. A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women's hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland-Altman analysis and paired t-test. For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p iPad-based LCVA test shows good agreement with Sloan testing in MS patients.

  18. Experimental test of static and dynamic characteristics of tilting-pad thrust bearings

    Directory of Open Access Journals (Sweden)

    Annan Guo

    2015-07-01

    Full Text Available The axial vibration in turbine machine has attracted more and more interest. Tilting-pad thrust bearings are widely used in turbine machines to support the axial load. The dynamic properties generated by oil film of the thrust pad have important effects on the axial vibration of the rotor-bearing system. It is necessary to develop the method to test the dynamic characteristics of thrust bearings. A new rig has been developed. The facility allows a complete set of bearing operating parameters to be measured. Parameters measured include oil temperatures, oil-film thickness, and pressure. The static load and dynamic load can be added on the thrust bearing in the vertical direction at the same time. The relative and absolute displacement vibrations of the test experimental bearing with the changes of dynamic force are measured, and the dynamic characteristics of the test bearing are obtained. The experimental results show clearly that the operating conditions influence largely on the pad static and dynamic characteristics.

  19. A pilot trial of the iPad tablet computer as a portable device for visual acuity testing.

    Science.gov (United States)

    Zhang, Zhao-tian; Zhang, Shao-chong; Huang, Xiong-gao; Liang, Ling-yi

    2013-01-01

    We evaluated the accuracy of an app for the iPad tablet computer (Eye Chart Pro) as a portable method of visual acuity (VA) testing. A total of 120 consecutive patients (240 eyes) underwent visual acuity test with an iPad 2 and a conventional light-box chart. The logMAR VA results from the iPad were significantly higher than those from the light-box (P iPad chart and the light-box chart, with 95% limits of agreement of -0.14 to 0.19. Two groups of patients were defined: in Group 1 there were 182 eyes with VA better than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 0.54 and by the light-box chart it was 0.52; there was no significant difference between them (P = 0.69). In Group 2 there were 58 eyes with VA equal to or worse than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 1.26 and was 1.10 by the light box; the result from the iPad was significantly lower (P iPad is reliable for VA testing only when the Snellen VA is better than 0.1 (20/200).

  20. Food allergens in mattress dust in Norwegian homes - a potentially important source of allergen exposure.

    Science.gov (United States)

    Bertelsen, R J; Faeste, C K; Granum, B; Egaas, E; London, S J; Carlsen, K-H; Lødrup Carlsen, K C; Løvik, M

    2014-01-01

    Sensitization to food allergens and food allergic reactions are mostly caused by ingesting the allergen, but can also occur from exposure via the respiratory tract or the skin. Little is known about exposure to food allergens in the home environment. The objective of this study was firstly to describe the frequency of detection of allergens from fish, egg, milk, and peanut in mattress dust collected from homes of 13-year-old adolescents and secondly to identify home characteristics associated with the presence of food allergen contamination in dust. Food allergens were measured by dot blot analysis in mattress dust from 143 homes in Oslo, Norway. We analysed associations between home characteristics (collected by parental questionnaires and study technicians) and food allergens by multivariate regression models. Fish allergen was detected in 46%, peanut in 41%, milk in 39%, and egg allergen in 22% of the mattress dust samples; only three samples contained none of these allergens. All four food allergens were more frequently detected in mattresses in small dwellings (Food allergens occurred frequently in beds in Norwegian homes, with dwelling size and proximity of kitchen and bedroom as the most important determinants. Due to the amount of time children spent in the bedroom, mattress dust may be an important source of exposure to food allergens. © 2013 John Wiley & Sons Ltd.

  1. Study on Load-displacement Test of Rubber Pads of Coal Mine Roadway Constructed by Shield

    Science.gov (United States)

    Yang, Yue; Chen, Xiaoguo; Yang, Liyun

    2017-12-01

    Shield method construction of coal mine roadway is the future trend of the development of deep coal mining. The main shaft supporting is the segment. There is rubber pads between segment and segment. The performance of compression deformation of rubber pad is essential for the overall stability of lining. Through load test, displacement of the rubber pad under load, the thrust force law of the rubber pad deformation, and provide a theoretical basis for the stability analysis of coal mine tunnel shield construction.

  2. Microcontrolled air-mattress for ulcer by pressure prevention

    Science.gov (United States)

    Pasluosta, Cristian F.; Fontana, Juan M.; Beltramone, Diego A.; Taborda, Ricardo A. M.

    2007-11-01

    An ulcer by pressure is produced when a constant pressure is exerted over the skin. This generates the collapse of the blood vessels and, therefore, a lack in the contribution of the necessary nutrients for the affected zone. As a consequence, the skin deteriorates, eventually causing an ulcer. In order to prevent it, a protocol must be applied to the patient, which is reflected on time and cost of treatment. There are some air mattresses available for this purpose, but whose performance does not fulfill all requirements. The prototype designed in our laboratory is based on the principle of the air mattress. Its objective is to improve on existing technologies and, due to an increased automation, reduce time dedication for personnel in charge of the patient. A clinical experience was made in the local Emergencies Hospital and also in an institution dedicated to aged patients care. In both cases, the results obtained and the comments from the personnel involved were favorable.

  3. Microcontrolled air-mattress for ulcer by pressure prevention

    International Nuclear Information System (INIS)

    Pasluosta, Cristian F; Fontana, Juan M; Beltramone, Diego A; Taborda, Ricardo A M

    2007-01-01

    An ulcer by pressure is produced when a constant pressure is exerted over the skin. This generates the collapse of the blood vessels and, therefore, a lack in the contribution of the necessary nutrients for the affected zone. As a consequence, the skin deteriorates, eventually causing an ulcer. In order to prevent it, a protocol must be applied to the patient, which is reflected on time and cost of treatment. There are some air mattresses available for this purpose, but whose performance does not fulfill all requirements. The prototype designed in our laboratory is based on the principle of the air mattress. Its objective is to improve on existing technologies and, due to an increased automation, reduce time dedication for personnel in charge of the patient. A clinical experience was made in the local Emergencies Hospital and also in an institution dedicated to aged patients care. In both cases, the results obtained and the comments from the personnel involved were favorable

  4. Microcontrolled air-mattress for ulcer by pressure prevention

    Energy Technology Data Exchange (ETDEWEB)

    Pasluosta, Cristian F; Fontana, Juan M; Beltramone, Diego A; Taborda, Ricardo A M [Universidad Nacional de Cordoba. Cordoba (Argentina)

    2007-11-15

    An ulcer by pressure is produced when a constant pressure is exerted over the skin. This generates the collapse of the blood vessels and, therefore, a lack in the contribution of the necessary nutrients for the affected zone. As a consequence, the skin deteriorates, eventually causing an ulcer. In order to prevent it, a protocol must be applied to the patient, which is reflected on time and cost of treatment. There are some air mattresses available for this purpose, but whose performance does not fulfill all requirements. The prototype designed in our laboratory is based on the principle of the air mattress. Its objective is to improve on existing technologies and, due to an increased automation, reduce time dedication for personnel in charge of the patient. A clinical experience was made in the local Emergencies Hospital and also in an institution dedicated to aged patients care. In both cases, the results obtained and the comments from the personnel involved were favorable.

  5. 76 FR 59014 - Standard for the Flammability of Mattresses and Mattress Pads; Technical Amendment

    Science.gov (United States)

    2011-09-23

    ... of the Standard; rather, SRM usage ensures continuity of a reliably high PFLB with low variability in... demonstrates that the PFLB performance of commercial cigarettes is subject to significant variability that can... industry has sufficient test data to support the hypothesis that RIP cigarettes consistently self...

  6. Mapping Emplaced Articulated Concrete Mattress Using Geoelectrical and Electromagnetic Techniques

    National Research Council Canada - National Science Library

    Sjostrom, Keith

    1998-01-01

    Articulated concrete mattresses (ACM) are structures placed parallel to the river current for the purpose of stabilizing the concave banks in river bends, reduce the effects of erosion, and maintain the river channel...

  7. Experimental test of static and dynamic characteristics of tilting-pad thrust bearings

    OpenAIRE

    Annan Guo; Xiaojing Wang; Jian Jin; Diann Y Hua; Zikai Hua

    2015-01-01

    The axial vibration in turbine machine has attracted more and more interest. Tilting-pad thrust bearings are widely used in turbine machines to support the axial load. The dynamic properties generated by oil film of the thrust pad have important effects on the axial vibration of the rotor-bearing system. It is necessary to develop the method to test the dynamic characteristics of thrust bearings. A new rig has been developed. The facility allows a complete set of bearing operating parameters ...

  8. A study of the behaviour of and the forces in a bed protecting mattress : The falling apron

    NARCIS (Netherlands)

    Vrijling, J.K.; Ravenstijn, P.

    2001-01-01

    In many cases the bottom around a structure that is exposed to current has to be protected by a mattress. The purpose of the mattress is to protect the soil besides the structure from erosion and scour, thus preserving the strength of the foundation of the structure. Examples are the bottom

  9. The impact of compliant surfaces on in-hospital chest compressions: effects of common mattresses and a backboard.

    NARCIS (Netherlands)

    Noordergraaf, G.J.; Paulussen, I.W.; Venema, A.; Berkom, P.F. van; Woerlee, P.H.; Scheffer, G.J.; Noordergraaf, A.

    2009-01-01

    PURPOSE: To evaluate, in a hospital setting, the influence of different, common mattresses, with and without a backboard, on chest movement during CPR. DESIGN AND SETTING: Sixty CPR sessions (140s each, 30:2, C:R ratio 1:1) were performed using a manikin on standard hospital mattresses, with or

  10. Characterization of High-Power Turbomachinery Tilting Pad Journal Bearings: First Results Obtained on a Novel Test Bench

    Directory of Open Access Journals (Sweden)

    Enrico Ciulli

    2018-01-01

    Full Text Available Tilting pad journal bearings are usually employed in turbomachines for their stable behavior at high rotational speeds. Devoted test rigs have been realized to validate the predictions of theoretical models. However, the design of new high-performance and large-size bearings needs to be supported by experimental investigations on high-performance large test rigs. The main characteristics of a recently built facility for testing large tilting pad journal bearings with diameters from 150 to 300 mm are described in this work. The test rig is versatile and can be used to test bearings of different size, configurations and to investigate the influence of many parameters, even the effect of misalignment. Sample results of the static characterization of a four-pad high-performance tilting pad journal bearing are reported evidencing some transient effects. A few sample dynamic results are also reported. The presented experimental results demonstrated the capabilities of the rig for investigating the static and the dynamic characteristics of the bearings accurately measuring slow and fast variables.

  11. Trial of a novel plasma gas disinfection system (Radica) to reduce mattress residual bacterial contamination in the acute hospital setting: a preliminary study.

    Science.gov (United States)

    Shiely, F; Fallon, D; Casey, C; Kerins, D M; Eustace, J A

    2017-02-01

    In routine clinical practice, mattresses are manually cleaned using specialised cleaning and high-level disinfecting fluids. While effective against a wide range of organisms, the success of this approach is dependent on a thorough and complete application and is likely to be susceptible to human error and thus variable. The efficacy of available infection control measures to reduce such mattress contamination is unknown as it is not subject to quality control measures. There is a pressing need to identify more effective methods to prevent cross contamination within the medical environment, given the lack of available treatment strategies. The purpose of this study is to investigate the ability of a new technology, gaseous technology, to reduce colonization levels, compared to standard cleaning, and so attenuate superficial nosocomial infections. We conducted a prospective, single-centre, open-label, non-randomized trial with blinded outcome assessments, comparing the standard cleaning of hospital mattresses with a novel plasma based disinfection system Radica™, followed by a standard post-cleaning culturing protocol (five swabs/mattress). The median (interquartile range) maximal colony count per mattress for the 20 Radica versus 7 routinely cleaned mattresses was 1 (1-2.7) versus Too-Numerous-to-Count (TNTC) (32-TNTC), respectively, p = 0.002. Of the 20 Radica™ treated mattresses, 12 (60 %) had no positive culture result while all of the standard cleaned mattresses had at least two positive cultures. The plasma based Radica disinfection system reduces mattress bacterial colonization levels as compared to routine cleaning. This is a potentially important technology in the health care system to reduce surface colonisation and hence nosocomial infections.

  12. 16 CFR Figure 8 to Part 1633 - Jig for Setting Mattresses and Foundation Sides in Same Plane

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Jig for Setting Mattresses and Foundation Sides in Same Plane 8 Figure 8 to Part 1633 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 8 Figure 8 to Part 1633—Jig for Setting Mattresses and Foundation Sides in Same Plane ER15MR06.007 ...

  13. Matrigel Mattress: A Method for the Generation of Single Contracting Human-Induced Pluripotent Stem Cell-Derived Cardiomyocytes.

    Science.gov (United States)

    Feaster, Tromondae K; Cadar, Adrian G; Wang, Lili; Williams, Charles H; Chun, Young Wook; Hempel, Jonathan E; Bloodworth, Nathaniel; Merryman, W David; Lim, Chee Chew; Wu, Joseph C; Knollmann, Björn C; Hong, Charles C

    2015-12-04

    The lack of measurable single-cell contractility of human-induced pluripotent stem cell-derived cardiac myocytes (hiPSC-CMs) currently limits the utility of hiPSC-CMs for evaluating contractile performance for both basic research and drug discovery. To develop a culture method that rapidly generates contracting single hiPSC-CMs and allows quantification of cell shortening with standard equipment used for studying adult CMs. Single hiPSC-CMs were cultured for 5 to 7 days on a 0.4- to 0.8-mm thick mattress of undiluted Matrigel (mattress hiPSC-CMs) and compared with hiPSC-CMs maintained on a control substrate (method enables the rapid generation of robustly contracting hiPSC-CMs and enhances maturation. This new method allows quantification of contractile performance at the single-cell level, which should be valuable to disease modeling, drug discovery, and preclinical cardiotoxicity testing. © 2015 American Heart Association, Inc.

  14. Multi-stage versus single-stage inflation and deflation cycle for alternating low pressure air mattresses to prevent pressure ulcers in hospitalised patients: a randomised-controlled clinical trial.

    Science.gov (United States)

    Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S

    2012-04-01

    The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation

  15. PsyPad: a platform for visual psychophysics on the iPad.

    Science.gov (United States)

    Turpin, Andrew; Lawson, David J; McKendrick, Allison M

    2014-03-11

    This article introduces PsyPad, a customizable, open-source platform for configuring and conducting visual psychophysics experiments on iPads without the need for any code development for the iPad. Stimuli for experiments are created off-line as a library of images. The PsyPad app (obtainable from the Apple App Store) presents the images according to either built-in, customizable staircase or method of constant stimuli procedures, mapping stimuli levels to images based on the image file names. On-screen buttons for responses are configurable and matched to "correct" using the image file name of any given stimulus. All actions are logged into a text file and sent to a specified server at the end of the test if an Internet connection is available. If the iPad is not connected, the results are uploaded the next time the iPad is online. We provide a secure server for this purpose, but the server-side software is also open source if researchers choose to run their own server.

  16. Multicenter comparison of the efficacy on prevention of pressure ulcer in postoperative patients between two types of pressure-relieving mattresses in China

    Science.gov (United States)

    Jiang, Qixia; Li, Xiaohua; Zhang, Aiqin; Guo, Yanxia; Liu, Yahong; Liu, Haiying; Qu, Xiaolong; Zhu, Yajun; Guo, Xiujun; Liu, Li; Zhang, Liyan; Bo, Suping; Jia, Jing; Chen, Yuejuan; Zhang, Rui; Wang, Jiandong

    2014-01-01

    Objective: Present study is designed to evaluate the effects of preventing pressure ulcer in surgical patients with two types of pressure-relieving mattresses. Methods: 1074 surgical patients from 12 hospitals in China were divided into A group (static air mattress with repositioning every 2 hours, n = 562) and B group (power pressure air mattress with repositioning every 2 hours, n = 512). The patient was subjected to a pressure-relieving mattress and observed from 0-5 days after surgery. Indications include the Braden scores, hospital-acquired pressure ulcers (HAPU) incidence and stage. Results: The Braden scores between two groups in five days after surgery were no significant (P > 0.05). The incidence of HAPU between two groups in same days also was no significant (1.07% vs. 0.98%, P > 0.05). The incidence of Stage I and stage II pressure ulcers in group A and B were 1.07% (6/562) and 0.98% (5/512), respectively (χ2 = 0.148, P = 0.882). Conclusion: The effects of preventing pressure ulcer in surgical patients with two types of pressure-relieving mattresses are similar, but the protocol by static air mattress with repositioning every 2 hours is benefit when no power. PMID:25356144

  17. An Enhanced Sensing Application Based on a Flexible Projected Capacitive-Sensing Mattress

    Directory of Open Access Journals (Sweden)

    Wen-Ying Chang

    2014-04-01

    Full Text Available This paper presents a cost-effective sensor system for mattresses that can classify the sleeping posture of an individual and prevent pressure ulcers. This system applies projected capacitive sensing to the field of health care. The charge time (CT method was used to sensitively and accurately measure the capacitance of the projected electrodes. The required characteristics of the projected capacitor were identified to develop large-area applications for sensory mattresses. The area of the electrodes, the use of shielding, and the increased length of the transmission line were calibrated to more accurately measure the capacitance of the electrodes in large-size applications. To offer the users comfort in the prone position, a flexible substrate was selected and covered with 16 × 20 electrodes. Compared with the static charge sensitive bed (SCSB, our proposed system-flexible projected capacitive-sensing mattress (FPCSM comes with more electrodes to increase the resolution of posture identification. As for the body pressure system (BPS, the FPCSM has advantages such as lower cost, higher aging-resistance capability, and the ability to sense the capacitance of the covered regions without physical contact. The proposed guard ring design effectively absorbs the noise and interrupts leakage paths. The projected capacitive electrode is suitable for proximity-sensing applications and succeeds at quickly recognizing the sleeping pattern of the user.

  18. A quantitative analysis of microcirculation in sore-prone pressure areas on conventional and pressure relief hospital mattresses using laser Doppler flowmetry and tissue spectrophotometry.

    Science.gov (United States)

    Rothenberger, Jens; Krauss, Sabrina; Held, Manuel; Bender, Dominik; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Constantinescu, Mihai Adrian; Jaminet, Patrick

    2014-11-01

    Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  19. Corrective Action Investigation Plan for Corrective Action Unit 252: Area 25 Engine Test Stand 1 Decontamination Pad, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    1999-08-20

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit 252 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 252 consists of Corrective Action Site (CAS) 25-07-02, Engine Test Stand-1 (ETS-1) Decontamination Pad. Located in Area 25 at the intersection of Road H and Road K at the Nevada Test Site, ETS-1 was designed for use as a mobile radiation checkpoint and for vehicle decontamination. The CAS consists of a concrete decontamination pad with a drain, a gravel-filled sump, two concrete trailer pads, and utility boxes. Constructed in 1966, the ETS-1 facility was part of the Nuclear Rocket Development Station (NRDS) complex and used to test nuclear rockets. The ETS-1 Decontamination Pad and mobile radiation check point was built in 1968. The NRDS complex ceased primary operations in 1973. Based on site history, the focus of the field investigation activities will be to determine if any primary contaminants of potential concern (COPCs) (including radionuclides, total volatile organic compounds, total semivolatile organic compounds, total petroleum hydrocarbons as diesel-range organics, Resource Conservation and Recovery Act metals, total pesticides, and polychlorinated biphenyls) are present at this site. Vertical extent of migration of suspected vehicle decontamination effluent COPCs is expected to be less than 12 feet below ground surface. Lateral extent of migration of COPCs is expected to be limited to the sump area or near the northeast corner of the decontamination pad. Using a biased sampling approach, near-surface and subsurface sampling will be conducted at the suspected worst-case areas including the sump and soil near the northeast corner of the decontamination pad. The results of this field investigation will support a defensible e

  20. TPC cathode read-out with C-pads

    International Nuclear Information System (INIS)

    Janik, R.; Pikna, M.; Sitar, B.; Strmen, P.; Szarka, I.

    2009-01-01

    A Time Projection Chamber with 'C' like shaped cathode pads was built and tested. It offers a low gas gain operation, a good pulse shape and a lightweight construction. The Pad Response Function (PRF), the cathode to anode pulse height ratios and the pad pulse shapes of the C-pad structure were measured and compared with planar cathode structures in two different wire geometries. The cathode to anode signal ratio was improved from between 0.2 and 0.4 up to 0.7. The PRF was considerably improved, it has a Gaussian shape and is narrower than in the case of the planar pads. The pulse shape from the C-pad read-out is similar to the pulse shape from a detector with a cylindrical shape of electrodes. A method for aluminum pad mass production based on a precise cold forging was developed and tested.

  1. Experimental and Numerical Simulation of Unbalance Response in Vertical Test Rig with Tilting-Pad Bearings

    Directory of Open Access Journals (Sweden)

    Mattias Nässelqvist

    2014-01-01

    Full Text Available In vertically oriented machines with journal bearing, there are no predefined static radial loads, such as dead weight for horizontal rotor. Most of the commercial software is designed to calculate rotordynamic and bearing properties based on machines with a horizontally oriented rotor; that is, the bearing properties are calculated at a static eccentricity. For tilting-pad bearings, there are no existing analytical expressions for bearing parameters and the bearing parameters are dependent on eccentricity and load angle. The objective of this paper is to present a simplified method to perform numerical simulations on vertical rotors including bearing parameters. Instead of recalculating the bearing parameters in each time step polynomials are used to represent the bearing parameters for present eccentricities and load angles. Numerical results are compared with results from tests performed in a test rig. The test rig consists of two guide bearings and a midspan rotor. The guide bearings are 4-pad tilting-pad bearings. Shaft displacement and strains in the bearing bracket are measured to determine the test rig’s properties. The comparison between measurements and simulated results shows small deviations in absolute displacement and load levels, which can be expected due to difficulties in calculating exact bearing parameters.

  2. Dynamic behavior of air lubricated pivoted-pad journal-bearing, rotor system. 2: Pivot consideration and pad mass

    Science.gov (United States)

    Nemeth, Z. N.

    1972-01-01

    Rotor bearing dynamic tests were conducted with tilting-pad journal bearings having three different pad masses and two different pivot geometries. The rotor was vertically mounted and supported by two three-pad tilting-pad gas journal bearings and a simple externally pressurized thrust bearing. The bearing pads were 5.1 cm (2.02 in.) in diameter and 2.8 cm (1.5 in.) long. The length to diameter ratio was 0.75. One pad was mounted on a flexible diaphragm. The bearing supply pressure ranged from 0 to 690 kilonewtons per square meter (0 to 100 psig), and speeds ranged to 38,500 rpm. Heavy mass pad tilting-pad assemblies produced three rotor-bearing resonances above the first two rotor critical speeds. Lower supply pressure eliminated the resonances. The resonances were oriented primarily in the direction normal to the diaphragm.

  3. A Randomized Comparative Study Evaluating Various Cough Stress Tests and 24-Hour Pad Test with Urodynamics in the Diagnosis of Stress Urinary Incontinence.

    Science.gov (United States)

    Henderson, Joseph W; Kane, Sarah M; Mangel, Jeffrey M; Kikano, Elias G; Garibay, Jorge A; Pollard, Robert R; Mahajan, Sangeeta T; Debanne, Sara M; Hijaz, Adonis K

    2018-06-01

    The cough stress test is a common and accepted tool to evaluate stress urinary incontinence but there is no agreement on how the test should be performed. We assessed the diagnostic ability of different cough stress tests performed when varying patient position and bladder volume using urodynamic stress urinary incontinence as the gold standard. The 24-hour pad test was also evaluated. We recruited women who presented to specialty outpatient clinics with the complaint of urinary incontinence and who were recommended to undergo urodynamic testing. A total of 140 patients were randomized to 4 cough stress test groups, including group 1-a comfortably full bladder, group 2-an empty bladder, group 3- a bladder infused with 200 cc saline and group 4-a bladder filled to half functional capacity. The sequence of standing and sitting was randomly assigned. The groups were compared by 1-way ANOVA or the generalized Fisher exact test. The κ statistic was used to evaluate agreement between the sitting and standing positions. The 95% CIs of sensitivity and specificity were calculated using the Wilson method. ROC analysis was done to evaluate the performance of the 24-hour pad test. The cough stress test performed with a bladder filled to half functional capacity was the best performing test with 83% sensitivity and 90% specificity. There was no statistically significant evidence that the sensitivity or specificity of 1 cough stress test differed from that of the others. The pad test had no significant predictive ability to diagnose urodynamic stress urinary incontinence (AUC 0.60, p = 0.08). Cough stress tests were accurate to diagnose urodynamic stress urinary incontinence. The 24-hour pad test was not predictive of urodynamic stress urinary incontinence and not helpful when used in conjunction with the cough stress test. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. A retrospective study to determine the incidence of pressure ulcers in burn patients using an alternating pressure mattress.

    Science.gov (United States)

    Still, Joseph M; Wilson, Joan; Rinker, Connie; Law, Edward; Craft-Coffman, Beretta

    2003-08-01

    In immobilized patients, unrelieved pressure can create decubitus ulcers over bony prominences. Those burn patients who require prolonged bed rest, are prone to the development of such problems. Various methods of reducing pressure on these areas, including frequent turning and the use of air fluidized and low air loss beds, have been adopted to attempt to prevent the development of this complication. The Pegasus Renaissance alternating pressure mattress is such a device, intended to reduce the incidence of decubitus ulcers. It was introduced at our burn unit and evaluated over a 29-month period. During the study period, 186 (13.4%) of 1390 acutely burned patients, believed to be at high risk for the development of decubiti, were placed on this mattress. Other patients were treated in the standard hospital bed. Care was otherwise the same. No decubitus ulcers developed in any of the patients treated on the Pegasus Renaissance mattress.

  5. Designing a new test for contrast sensitivity function measurement with iPad.

    Science.gov (United States)

    Rodríguez-Vallejo, Manuel; Remón, Laura; Monsoriu, Juan A; Furlan, Walter D

    2015-01-01

    To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland-Altman plots. Statistically significant differences in CSF of both groups were found due to the change of the ClinicCSF version (piPad retina showed no significant differences with FACT test when the same contrast sensitivity steps were used. In addition, it is shown that the accurateness of a vision screening could be improved with the use of an appropriate psychophysical method. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  6. IBM ThinkPad radiation testing and recovery during EUROMIR missions

    International Nuclear Information System (INIS)

    Martignano, M.; Harboe-Sorensen, R.

    1995-01-01

    This paper presents the results of an experiment, conducted on-board the Russian MIR Space Station during a joint Russian and European mission, EUROMIR '94. A commercially available IBM ThinkPad 750C was evaluated by running a software system which monitored the notebook's behavior and counted the number of single event upsets. The used software system and ground verification tests are also presented. Finally, another software system, able to ruggedize normal personal computers for usage in space, is described

  7. Dynamic test of the ITER blanket key and ceramic insulated pad

    International Nuclear Information System (INIS)

    Khomyakov, S.; Sysoev, G.; Strebkov, Yu.; Kucherov, A.; Ioki, K.

    2010-01-01

    The dynamic testing of the blanket module's key integrated into ITER vacuum vessel portion has been performed in 2008 to investigate its capability to react the electro-magnetic (EM) loads. The preliminary analysis showed the large dynamic amplification factor (DAF) of the reactions because of technological gaps between the blanket module and key. Shock load may yield the bronze pads, which protect the blanket electrical insulation from damage. However the dynamic analysis of such particularly non-linear system needs an experimental ground and confirmation. Toward this end, as well as demonstration of the key reliability, the special test facility has been made, and the full-scale mock-up of the inboard intermodular key was tested. So as not to scale non-linear dynamic parameters, 1-ton mass was built on the single flexible support. The key was welded in a 60-mm thick steel plate modeled with a fragment of the VV. The different gaps were set in between the bronze pad of the key and the mass shock worker. This system (supplemented with some additional constraints) has natural oscillations like as the 4-ton module built on four flexible supports. Thus the most critical radial torque might be modeled with a straight force. The objectives of the test were as follows: dynamic response, DAF and damping factor determination; measurement of the strain oscillations in the key's base and in the weld seam; comparison of the measured data with computation results. The paper will present the analytical grounds of the testing conditions, test facility description, analytical adaptation of the facility, experimental results, its comparison with analysis and discussion, and guidelines for the next experimental phase.

  8. Geographical variation and the determinants of domestic endotoxin levels in mattress dust in Europe

    NARCIS (Netherlands)

    Chen, C.M.; Thiering, E.; Doekes, G.; Zock, J.P.; Bakolis, I.; Norbäck, D.; Sunyer, J.; Villani, S.; Verlato, G.; Täubel, M.; Jarvis, D.

    2012-01-01

    Endotoxin exposures have manifold effects on human health. The geographical variation and determinants of domestic endotoxin levels in Europe have not yet been extensively described. To investigate the geographical variation and determinants of domestic endotoxin concentrations in mattress dust in

  9. Finite element modeling for predicting the contact pressure between a foam mattress and the human body in a supine position.

    Science.gov (United States)

    Lee, Wookjin; Won, Byeong Hee; Cho, Seong Wook

    2017-01-01

    In this paper, we generated finite element (FE) models to predict the contact pressure between a foam mattress and the human body in a supine position. Twenty-year-old males were used for three-dimensional scanning to produce the FE human models, which was composed of skin and muscle tissue. A linear elastic isotropic material model was used for the skin, and the Mooney-Rivlin model was used for the muscle tissue because it can effectively represent the nonlinear behavior of muscle. The contact pressure between the human model and the mattress was predicted by numerical simulation. The human models were validated by comparing the body pressure distribution obtained from the same human subject when he was lying on two different mattress types. The experimental results showed that the slope of the lower part of the mattress caused a decrease in the contact pressure at the heels, and the effect of bone structure was most pronounced in the scapula. After inserting a simple structure to function as the scapula, the contact pressure predicted by the FE human models was consistent with the experimental body pressure distribution for all body parts. These results suggest that the models proposed in this paper will be useful to researchers and designers of products related to the prevention of pressure ulcers.

  10. Mobile Tech and the Librarian: The iTest iPad Project.

    Science.gov (United States)

    Hamasu, Claire; Bramble, John

    A 2012 project provided forty-eight health sciences librarians from primarily hospital and academic health sciences libraries with an Apple iPad2 along with training and support on its use. Project objectives were to determine how participants would adopt the iPad into their daily operations and what form of leadership role they would play while participating in the project. By project's end eighty-nine percent indicated they would continue using the iPad primarily as a productivity tool and to provide point of need services. Project data indicated that librarians assumed a leadership role promoting the use of mobile technology and the applications available.

  11. Mobile Tech and the Librarian: The iTest iPad Project

    Science.gov (United States)

    Hamasu, Claire; Bramble, John

    2015-01-01

    A 2012 project provided forty-eight health sciences librarians from primarily hospital and academic health sciences libraries with an Apple iPad2 along with training and support on its use. Project objectives were to determine how participants would adopt the iPad into their daily operations and what form of leadership role they would play while participating in the project. By project's end eighty-nine percent indicated they would continue using the iPad primarily as a productivity tool and to provide point of need services. Project data indicated that librarians assumed a leadership role promoting the use of mobile technology and the applications available. PMID:26997921

  12. 75 FR 67047 - Standard for the Flammability of Mattresses and Mattress Pads

    Science.gov (United States)

    2010-11-01

    ... upholstery fabric manufacturers. Response: As discussed in greater detail in the preliminary regulatory... Environmental Quality regulations and CPSC procedures for environmental review, the Commission has assessed the...

  13. Correlations for Saturation Efficiency of Evaporative Cooling Pads

    Science.gov (United States)

    Jain, J. K.; Hindoliya, D. A.

    2014-01-01

    This paper presents some experimental investigations to obtain correlations for saturation efficiency of evaporative cooling pads. Two commonly used materials namely aspen and khus fibers along with new materials namely coconut fibers and palash fibers were tested in a laboratory using suitably fabricated test setup. Simple mathematical correlations have been developed for calculating saturation efficiency of evaporating cooling pads which can be used to predict their performance at any desired mass flow rate. Performances of four different pad materials were also compared using developed correlations. An attempt was made to test two new materials (i.e. fibers of palash wood and coconut) to check their suitability as wetted media for evaporative cooling pads. It was found that Palash wood fibers offered highest saturation efficiency compared to that of other existing materials such as aspen and khus fibers at different mass flow rate of air.

  14. A retrospective study to determine the incidence of pressure ulcers in burn patients using a low air loss pressure relieving mattress.

    Science.gov (United States)

    Still, Joseph M; Wilson, Joan; Rinker, Connie; Law, Edward; Craft-Coffman, Beretta

    2003-06-01

    In immobilized patients, unrelieved pressure can create decubitus ulcers over bony prominences. Those burn patients who require prolonged bed rest, are prone to the development of such problems. Various methods of reducing pressure on these areas, including frequent turning and the use of air fluidized and low air loss beds, have been adopted to attempt to prevent the development of this complication. The Pegasus Renaissance alternating pressure mattress is such a device, intended to reduce the incidence of decubitus ulcers. It was introduced at our burn unit and evaluated over a 29-month period. During the study period, 186 (13.4%) of 1390 acutely burned patients, believed to be at high risk for the development of decubiti, were placed on this mattress. Other patients were treated in the standard hospital bed. Care was otherwise the same. No decubitus ulcers developed in any of the patients treated on the Pegasus Renaissance mattress.

  15. An assessment of the iPad as a testing platform for distance visual acuity in adults

    Science.gov (United States)

    Black, J M; Jacobs, R J; Phillips, G; Chen, L; Tan, E; Tran, A; Thompson, B

    2013-01-01

    Objectives Visual acuity is a common measurement in general practice, and the advent of new technology such as tablet computers offers a change in the way in which these tests are delivered. The aim of this study was to assess whether measurements of distance visual acuity using LogMAR letter charts displayed on an iPad tablet computer were in agreement with standard clinical tests of visual acuity in adults with normal vision. Design Blinded, diagnostic test study. Setting Single centre (University) in Auckland, New Zealand. Participants University staff and students (n=85). Participants were required to have visual acuity better than 6/60 and wear habitual refractive correction during testing. Participants were excluded if there was any history of ocular pathology. Primary and secondary outcome measures Visual acuity measured under a number of conditions. Results The iPad tablet with its glossy screen was highly susceptible to glare resulting in acuity measurements that were significantly poorer (approximately 2 LogMAR lines) than those made using an ETDRS chart and a standard computerised testing system (n=56). However, fitting the iPad with an antiglare screen and positioning the device away from sources creating reflected (veiling) glare resulted in acuity measurements that were equivalent those made using gold standard charts (n=29). Conclusions Tablet computers are an attractive option for visual acuity measurement due to portability, the ability to randomise letters, automated scoring of acuity and the ability to select from a range of charts. However, these devices are only suitable for use in situations where sources of glare can be eliminated. PMID:23794568

  16. Launch Pad in a Box

    Science.gov (United States)

    Mantovani, James; Tamasy, Gabor; Mueller, Rob; Townsend, Van; Sampson, Jeff; Lane, Mike

    2016-01-01

    NASA Kennedy Space Center (KSC) is developing a new deployable launch system capability to support a small class of launch vehicles for NASA and commercial space companies to test and launch their vehicles. The deployable launch pad concept was first demonstrated on a smaller scale at KSC in 2012 in support of NASA Johnson Space Center's Morpheus Lander Project. The main objective of the Morpheus Project was to test a prototype planetary lander as a vertical takeoff and landing test-bed for advanced spacecraft technologies using a hazard field that KSC had constructed at the Shuttle Landing Facility (SLF). A steel pad for launch or landing was constructed using a modular design that allowed it to be reconfigurable and expandable. A steel flame trench was designed as an optional module that could be easily inserted in place of any modular steel plate component. The concept of a transportable modular launch and landing pad may also be applicable to planetary surfaces where the effects of rocket exhaust plume on surface regolith is problematic for hardware on the surface that may either be damaged by direct impact of high speed dust particles, or impaired by the accumulation of dust (e.g., solar array panels and thermal radiators). During the Morpheus free flight campaign in 2013-14, KSC performed two studies related to rocket plume effects. One study compared four different thermal ablatives that were applied to the interior of a steel flame trench that KSC had designed and built. The second study monitored the erosion of a concrete landing pad following each landing of the Morpheus vehicle on the same pad located in the hazard field. All surfaces of a portable flame trench that could be directly exposed to hot gas during launch of the Morpheus vehicle were coated with four types of ablatives. All ablative products had been tested by NASA KSC and/or the manufacturer. The ablative thicknesses were measured periodically following the twelve Morpheus free flight tests

  17. Diagnostic accuracy of heel pad palpation - A phantom study

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Matteoli, Sara; Wilhjelm, Jens E.

    2008-01-01

    Falanga torture involves repetitive blunt trauma to the soles of the feet and typically leaves few detectable changes. Reduced elasticity in the heel pads has been reported as characteristic sequelae and palpatory testing of heel pad elasticity is therefore part of medicolegal assessment of alleged...... torture victims. The goal was to test the accuracy of two experienced investigators in determining whether a heel pad model was soft, medium or hard. The skin-to-bone distance in the models varied within the human range....

  18. iPad portable genius

    CERN Document Server

    McFedries, Paul

    2013-01-01

    Make the most of your iPad with these savvy tips and techniques The iPad, iPad Air, and iPad mini are taking the world by storm. This no-nonsense guide covers everything you want to know to take full advantage of all your iPad has to offer. Along with necessary basics about the newest iPad; iPad Air, iPad mini; and iOS; it gives you smart; innovative ways to accomplish a variety of tasks and tips to help you maximize the convenience of your Apple digital lifestyle. More than 100 million iPads have been sold; and the number continues to growHip and practical; Portable Genius guides are packed

  19. Emission of phthalates and phthalate alternatives from vinyl flooring and crib mattress covers: the influence of temperature.

    Science.gov (United States)

    Liang, Yirui; Xu, Ying

    2014-12-16

    Emissions of phthalates and phthalate alternatives from vinyl flooring and crib mattress covers were measured in a specially designed chamber. The gas-phase concentrations versus time were measured at four different temperatures, that is, 25, 36, 45, and 55 °C. The key parameter that controls the emissions (y0, gas-phase concentration in equilibrium with the material phase) was determined, and the emissions were found to increase significantly with increasing temperature. Both the material-phase concentration (C0) and the chemical vapor pressure (Vp) were found to have great influence on the value of y0. The measured ratios of C0 to y0 were exponentially proportional to the reciprocal of temperature, in agreement with the van't Hoff equation. A emission model was validated at different temperatures, with excellent agreement between model calculations and chamber observations. In residential homes, an increase in the temperature from 25 to 35 °C can elevate the gas-phase concentration of phthalates by more than a factor of 10, but the total airborne concentration may not increase that much for less volatile compounds. In infant sleep microenvironments, an increase in the temperature of mattress can cause a significant increase in emission of phthalates from the mattress cover and make the concentration in the infant's breathing zone about four times higher than that in the bulk room air, resulting in potentially high exposure.

  20. CFD Analysis of A Starved Four-Pad Tilting-Pad Journal Bearing with An Elastic Support of Pads

    Science.gov (United States)

    Parovay, E. F.; Falaleev, S. V.

    2018-01-01

    Tilting-pad journal bearings are widely used in technics. Oil starvation operation regime is not common for hydrodynamic bearings. However, correctly designed low-flow journal bearing have to operate efficiently and consistently on high rotor speeds. An elastic support of bearing pads is a set of elastic pins made of steel. Elastic support allows pads to self-align and achieve an optimal operational mode. The article presents the thermohydrodynamic performance of an axial journal bearing. The study deals with 60 mm diameter four-pad tilting-pad journal bearing, submitted to a static load varying from 1000 to 30000 N with a rotating speed varying from 1000 to 10000 rpm. The investigation focuses on numerical studying the characteristics of low-flow tilting-pad journal bearings under oil starvation conditions. Dependencies of the bearing performance on the load, rotational speed of the shaft, and the size of the radial clearance are presented.

  1. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.

    Science.gov (United States)

    Bhatia, Sanjeev; Civitarese, David M; Turnbull, Travis Lee; LaPrade, Christopher M; Nitri, Marco; Wijdicks, Coen A; LaPrade, Robert F

    2016-03-01

    Complete radial tears of the medial meniscus have been reported to be functionally similar to a total meniscectomy. At present, there is no consensus on an ideal technique for repair of radial midbody tears of the medial meniscus. Prior attempts at repair with double horizontal mattress suture techniques have led to a reportedly high rate of incomplete healing or healing in a nonanatomic (gapped) position, which compromises the ability of the meniscus to withstand hoop stresses. A newly proposed 2-tunnel radial meniscal repair method will result in decreased gapping and increased ultimate failure loads compared with the double horizontal mattress suture repair technique under cyclic loading. Controlled laboratory study. Ten matched pairs of male human cadaveric knees (average age, 58.6 years; range, 48-66 years) were used. A complete radial medial meniscal tear was made at the junction of the posterior one-third and middle third of the meniscus. One knee underwent a horizontal mattress inside-out repair, while the contralateral knee underwent a radial meniscal repair entailing the same technique with a concurrent novel 2-tunnel repair. Specimens were potted and mounted on a universal testing machine. Each specimen was cyclically loaded 1000 times with loads between 5 and 20 N before experiencing a load to failure. Gap distances at the tear site and failure load were measured. The 2-tunnel repairs exhibited a significantly stronger ultimate failure load (median, 196 N; range, 163-212 N) than did the double horizontal mattress suture repairs (median, 106 N; range, 63-229 N) (P = .004). In addition, the 2-tunnel repairs demonstrated decreased gapping at all testing states (P meniscus significantly decrease the ability of the meniscus to dissipate tibiofemoral loads, predisposing patients to early osteoarthritis. Improving the ability to repair medial meniscal radial tears in a way that withstands cyclic loads and heals in an anatomic position could significantly

  2. Dermatophagoides pteronyssinus (Trouessart, 1897) in mattress and floor dust in a temperate climate (Acari : Pyroglyphidae)

    NARCIS (Netherlands)

    Bronswijk, van J.E.M.H.

    1973-01-01

    The arthropod fauna of mattress dust, bedroom dust and living-room dust was sampled during a 1-year period in a center for asthmatic children (near Nijmegen, The Netherlands) with the aid of a vacuum cleaner, Berlese funnels and a flotation method. Dermatophagoides pteronyssinus was most abundant;

  3. EL device pad-printed on a curved surface

    International Nuclear Information System (INIS)

    Lee, Taik-Min; Hur, Shin; Kim, Jae-Hyun; Choi, Hyun-Cheol

    2010-01-01

    This paper is unique in that the electroluminescence (EL) display device is fabricated on a curved surface using the pad-printing method. The precision of the pad-printing process is explored to verify whether it can be used for micro patterning. The minimum pattern size and pattern distortion, which is caused by use of the pad, were tested and simulated. The minimal pattern was found to be 35 µm wide and 2.4 µm thick. Pattern distortion when pad-printing on a flat surface, caused by the deformation of the silicon pad, was less than 5 µm. Numerical analysis shows how to estimate pattern distortion when pad-printing on a curved surface. The proposed EL display device consists of five layers, namely a bottom electrode, dielectric layer, phosphor, transparent electrode and a bus electrode. The ink of each layer was reformulated with solvents and the pad-printing conditions were controlled. A PEN film was used first in order to realize the pad-printing process condition of each layer. Finally, the EL display device was printed onto a dish with a radius of curvature of 80 mm. The luminance was 180 cd m −2

  4. Orion Pad Abort 1 Crew Module Inertia Test Approach and Results

    Science.gov (United States)

    Herrera, Claudia; Harding, Adam

    2010-01-01

    The Flight Loads Laboratory at the Dryden Flight Research Center conducted tests to measure the inertia properties of the Orion Pad Abort 1 (PA-1) Crew Module. These measurements were taken to validate analytical predictions of the inertia properties of the vehicle and assist in reducing uncertainty for derived aero performance results calculated post launch. The first test conducted was to determine the Ixx of the Crew Module. This test approach used a modified torsion pendulum test step up that allowed the suspended Crew Module to rotate about the x axis. The second test used a different approach to measure both the Iyy and Izz properties. This test used a Knife Edge fixture that allowed small rotation of the Crew Module about the y and z axes. Discussions of the techniques and equations used to accomplish each test are presented. Comparisons with the predicted values used for the final flight calculations are made. Problem areas, with explanations and recommendations where available, are addressed. Finally, an evaluation of the value and success of these techniques to measure the moments of inertia of the Crew Module is provided.

  5. A randomized trial of exothermic mattresses for preterm newborns in polyethylene bags.

    LENUS (Irish Health Repository)

    McCarthy, Lisa K

    2013-07-01

    Hypothermia on admission to the NICU is associated with increased mortality in preterm infants. Many newborns are hypothermic on admission despite using polyethylene bags (PBs). Using exothermic mattresses (EMs) in addition to PBs may reduce hypothermia but increase hyperthermia. We wished to determine whether placing preterm newborns in PBs on EMs in the DR results in more infants with rectal temperature outside the range 36.5 to 37.5°C on NICU admission.

  6. Effect of mattress and pillow encasings on children with asthma and house dust mite allergy

    DEFF Research Database (Denmark)

    Halken, Susanne; Høst, Arne; Niklassen, Ulla

    2003-01-01

    BACKGROUND: House dust mite (HDM) allergy is a frequent cause of allergic asthma in children. Reduction of exposure seems to be the most logical way to treat these patients. OBJECTIVE: Our aim was to investigate whether mattress and pillow encasings resulted in an effective long-term control of H...

  7. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    Science.gov (United States)

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  8. Diagnosis of heel pad injuries

    DEFF Research Database (Denmark)

    Matteoli, Sara

    The biomechanics of in vivo heel pads has been investigated for more than 30 years, but unfortunately numerical results from the many individual investigators cannot be compared due to the different methodologies used, and the sometimes modest number of subjects investigated. The overall aim...... of the present thesis is to obtain a thorough understanding of the mechanical properties of in vivo human heel pad by studying the anatomical and physiological structure of healthy and diseased tissue, and to develop quantitative methods for diagnosing injuries. A compression device was built in order to record...... load-displacement curves from in vivo heel pads. To ensure applicability also for pathological feet, the device uses force levels lower than those needed to reproduce the physiological conditions of walking. One hundred twenty seven healthy volunteers were enrolled for compression tests and ultrasound...

  9. Pad for holding a load against a surface by suction

    International Nuclear Information System (INIS)

    Farmer, R.C.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention concerns suction pads for supporting loads. Specifically, the suction pad is part of a pair of pads located at the ends of a bridge forming a vehicle for transporting instruments for the non-destructive testing of a large vessel intended to contain a fuel assembly for a nuclear reactor immersed in a liquid metal coolant. For example, the vehicle is of the type described in the French patent application filed this day under the heading 'Vehicle for transporting instruments for testing against a wall' [fr

  10. iPad for the older and wiser get up and running with your Apple iPad, iPad Air and iPad Mini

    CERN Document Server

    McManus, Sean

    2013-01-01

    Apple's iPad puts a limitless world of entertainment, communication, and everyday functionality in the palms of your hands. iPad for the Older and Wiser, 4th Edition quickly teaches you how to make the most of your new gadget with easy-to-follow instructions. Fully updated to include the iPad Air and iOS 7, this step-by-step guide shows you exactly how to set up your device and discover what it can do - all in jargon-free language. Learn how to: Set up your iPad and copy music and photos from your computerKeep in touch with email and messagesBrowse the web and shop onlineHave video chats wi

  11. Flour pads: devices to improve CHESS fat suppression.

    Science.gov (United States)

    Moriya, Susumu; Miki, Yukio; Miyati, Tosiaki; Kanagaki, Mitsunori; Yokobayashi, Tsuneo

    2014-01-01

    We compared the suppression of lingering fat signals in chemical shift selective (CHESS) images by pads filled with flour and pads filled with rice in a phantom and human subjects. First, we prepared a phantom by creating an empty space in a mass of lard and filling the space with air, rice, or flour. Then, we obtained MR images of the phantoms in the center of the magnetic field and at a position 8 cm to the left (off-center) to compare lingering fat signals. MR images of the knee were obtained in 10 healthy volunteers using CHESS after placing a polyurethane sponge pillow, rice pad, or flour pad in the popliteal space under the flexed knee. We visually assessed the number of areas with lingering fat signals and the statistical differences among the groups were assessed using Tukey's test. Similarly to rice, flour clearly decreased lingering fat signals in the phantom study. A similar effect was obtained in the off-center images. In the volunteer study, the mean number of areas with lingering fat signals was 2.5 with a sponge pillow, 0.5 with the rice pad, and 0.3 with the flour pad. Those numbers were significantly different using flour pad and rice pad compared with sponge pillow (P CHESS images.

  12. Development and field performance of indy race car head impact padding.

    Science.gov (United States)

    Melvin, J W; Bock, H; Anderson, K; Gideon, T

    2001-11-01

    The close-fitting cockpit of the modern Indy car single seat race car has the potential to provide a high level of head and neck impact protection in rear and side impacts. Crash investigation has shown that a wide variety of materials have been used as the padding for these cockpits and, as a result, produced varying outcomes in crashes. Additionally, these pads have not always been positioned for optimal performance. The purpose of this study was to investigate the head impact performance of a variety of energy-absorbing padding materials under impact conditions typical of Indy car rear impacts and to identify superior materials and methods of improving their performance as race car head pads. An extensive series of tests with the helmeted Hybrid III test dummy head and neck on an impact mini-sled was conducted to explore head padding concepts. Following this, a performance specification for a simplified impact test using a rigid headform that simulates the helmeted head was developed and recommendations for performance levels of head padding based on biomechanical data on helmeted head impacts were made. In 1997, during the time that the head pad research was being performed, the Indy Racing League introduced a new chassis specification for their cars. There were a number of rear- and side-impact crashes during that season that resulted in seven severe head injuries. Examples of the head padding in those cars were included in the experimental study. The results of the head pad research were used to specify new padding materials that met the new biomechanical criteria. The placement of the head pads was also changed for better location of the padding. These changes instituted in 1998 have reduced the number of head injuries in crashes similar to or more severe than those of 1997 and have resulted in only occasional moderate head injuries (concussions) in the 1998 and 1999 seasons.

  13. Investigations on the visco-elastic behaviour of a human healthy heel pad: in vivo compression tests and numerical analysis

    DEFF Research Database (Denmark)

    Matteoli, Sara; Fontanella, Chiara G.; Carniel, Emanuele L.

    2013-01-01

    The aim of this study was to investigate the viscoelastic behaviour of the human heel pad by comparing the stress–relaxation curves obtained from a compression device used on an in vivo heel pad with those obtained from a threedimensional computer-based subject-specific heel pad model subjected...... numerical analyses were performed to interpret the mechanical response of heel tissues, with loading conditions and displacement rate in agreement with experimental tests. The heel tissues showed a non-linear, viscoelastic behaviour described by characteristic hysteretic curves, stress......–relaxation and viscous recovery phenomena. The reliability of the investigations was validated by the interpretation of the mechanical response of heel tissues under the application of three pistons with diameter of 15, 20 and 40 mm, at the same displacement rate of about 1.7 mm/s. The maximum and minimum relative...

  14. Impacts of iPad attributes, Lifestyles and media dependency on adoption of iPad and intensity of iPad usage in Mainland China

    OpenAIRE

    Kevin, Li Xinpeng

    2012-01-01

    The goal of this exploratory research is to identify attributes that can distinctly characterize iPad and examine the predictive power of iPad attributes, lifestyles, media dependency, and demographics on adoption of iPad, iPad usage patterns and intensity of iPad usage. Using a snowballing sample, an online survey was conducted with 623 university students in Mainland China, among which 217 were iPad users and 406 were non-users. Results of regression analyses show that application affordanc...

  15. Cement-base bearing pads mortar for connections in the precast concrete: study of surface roughness

    Directory of Open Access Journals (Sweden)

    M. K. El Debs

    Full Text Available Bearing pads are used in precast concrete connections to avoid concentrated stresses in the contact area between the precast elements. In the present research, the bearing pads are Portland cement mortar with styrene-butadiene latex (SB, lightweight aggregate (expanded vermiculite-term and short fibers (polypropylene, glass and PVA, in order to obtain a material with low modulus of elasticity and high tenacity, compared with normal Portland cement mortar. The objective of this paper is to analyze the influence of surface roughness on the pads and test other types of polypropylene fibers. Tests were carried out to characterize the composite and test on bearing pads. Characterization tests show compressive strength of 41MPa and modulus of elasticity of 12.8GPa. The bearing pads tests present 30% reduction of stiffness in relation to a reference mortar. The bearing pads with roughness on both sides present a reduction up to 30% in stiffness and an increase in accumulated deformation of more than 120%, regarding bearing pads with both sides smooth.

  16. Predict optimize the friction characteristics of brake pads; Brake pad no masatsu tokusei no yosoku to saitekika

    Energy Technology Data Exchange (ETDEWEB)

    Saotome, H [Nissin Kogyo Co., Tokyo (Japan); Kato, T [The University of Tokyo, Tokyo (Japan)

    1997-10-01

    The effect of the friction and the wear properties of brake pads were experimentally studied using a test rig of scale of 1/10 of the system used in a commercial car. The experimental data were investigated by the Multiple Regression Analysis and the Neural Network, and the effects of volume % of components on the friction and the wear properties were predicted. In addition the components of brake pads are optimized by Genetic Algorithms. 8 refs., 9 figs., 4 tabs.

  17. iPad Made Simple

    CERN Document Server

    Trautschold, Martin; Learning, MSL Made Simple

    2010-01-01

    The new iPad is sleek, powerful, and most importantly, it's much more than just a big iPhone. Your iPad is can be used for reading, surfing the web, emailing, watching TV/Movies, getting work done, and much more. And with the upcoming wave of iPad apps, the possibilities are endless. iPad X Made Simple clarifies all of the key features on the iPad, introduces what's new, and also reveals dozens of time-saving shortcuts and techniques. The book has over 1,000 screen shots that are carefully annotated with step-by-step instructions. * Clear instructions on how to set up and use the iPad * Illust

  18. Menstrual pad, a cervical cancer screening tool, a population-based study in rural India.

    Science.gov (United States)

    Budukh, Atul; Palayekar, Vrushali; Maheshwari, Amita; Deodhar, Kedar; Purwar, Pallavi; Bagal, Sonali; Vadigoppula, Ashok; Lokhande, Manoj; Panse, Nandkumar; Dikshit, Rajesh; Badwe, Rajendra

    2017-07-12

    In the rural areas of India, women generally use a piece of old cloth as a menstrual device. The aim of this study was to detect human papilloma virus (HPV) from menstrual blood on the menstrual pad and assess whether this could be a useful screening tool for cervical cancer. In Jamkhed area of rural Maharashtra, (population A), we collected menstrual pads from women who provided consent in the 30-50 year age group. The women who had provided menstrual pads underwent HC2 testing. We standardized the method for extracting DNA by PCR from the menstrual pad. The women who tested HPV positive, on the basis of HC2/PCR testing, underwent colposcopy. In the rural population of Pune area of Maharashtra state (population B), menstrual pads were collected. HPV was tested using the PCR method. HPV-positive women and a few HPV-negative women, selected randomly, underwent colposcopy and HC2 testing. In population A, 164 women provided their used menstrual pads and also underwent an HC2 screening test. Of these, six (3.2%) cases were reported as HPV positive. In population B, 365 women provided their used menstrual pads for HPV testing, of which 18 (4.9%) cases were diagnosed as HPV positive. The women who tested HPV positive, on the basis of PCR testing, and 10% randomly selected HPV-negative cases (37) and 18 women who voluntary requested testing underwent colposcopy and HC2 testing. The sensitivity of menstrual pad HPV testing compared with gold standard HC2 testing was 83% [95% confidence interval (CI): 0.47-0.97], 67% (95% CI: 0.30-0.91) and specificity was 99% (95% CI: 0.96-0.99), 88% (95% CI: 0.77-0.94) in population A and population B, respectively. The sensitivity of diagnosing CIN lesion was 83% (95% CI: 0.44-0.97) and specificity was 95% (95% CI: 0.91-0.97). On the basis of the sensitivity and specificity results, and the completely noninvasive, simple and convenient method of detecting HPV, menstrual pad might be considered a cervical cancer screening tool in rural

  19. POWER SPECTRUM DENSITY (PSD ANALYSIS OF AUTOMOTIVE PEDAL-PAD

    Directory of Open Access Journals (Sweden)

    AHMED RITHAUDDEEN YUSOFF

    2016-04-01

    Full Text Available Vibration at the pedal-pad may contribute to discomfort of foot plantar fascia during driving. This is due to transmission of vibration to the mount, chassis, pedal, and then to the foot plantar fascia. This experimental study is conducted to determine the estimation of peak value using the power spectral density of the vertical vibration input at the foot. The power spectral density value is calculated based on the frequency range between 13 Hz to 18 Hz. This experiment was conducted using 12 subjects testing on three size of pedal-pads; small, medium and large. The result shows that peak value occurs at resonance frequency of 15 Hz. The PSD values at that resonance frequency are 0.251 (m/s2 2/Hz for small pedal-pad, followed by the medium pedal-pad is at 0.387 (m/s2 2/Hz and lastly for the large pedal-pad is at 0.483 (m/s22/Hz. The resultsindicate that during driving, the foot vibration when interact with the large pedal-pad contributed higher stimulus compared with the small and medium pedal-pad. The pedal-pad size plays an important role in the pedal element designs in terms of vibration-transfer from pedal-pads on the feet, particularly to provide comfort to the driver while driving.

  20. The primary factor for suture configuration at rotator cuff repair: Width of mattress or distance from tear edge

    Directory of Open Access Journals (Sweden)

    Onur Hapa

    2016-08-01

    Conclusion: Bite size from the edge of the tendon seems to be more important than the width of the mattress. The curve of the suture passing device may also have an effect on the strength of the suture tendon interface.

  1. TypePad For Dummies

    CERN Document Server

    Nelson, Melanie

    2010-01-01

    TypePad for Dummies will be on guiding readers through the technical tasks necessary for starting, using and customizing a TypePad blog. It will comprehensively explain choosing the right TypePad membership plan, singing up, configuring, using and customizing a blog using the TypePad system. It will also include: Illustrations from real-world blogs with screenshots and specific examples that bring the book's concepts and ideas to life.; Step-by-step tutorials that will walk readers through the process of signing up for a new TypePad blog and getting down the business of publishing their conten

  2. iPad Portable Genius

    CERN Document Server

    McFedries, Paul

    2010-01-01

    Everything everyone wants to know about using the Apple iPad. On January 27, 2010, Apple announced the latest in its line of revolutionary, ultraportable devices - the iPad. iPad Portable Genius is the latest in a line of ultra handy, go-to and goes-with you anywhere guides for getting the most out of a new Apple product. Written to provide readers with highly useful information that's easily accessible, iPad Portable Genius is full of tips, tricks and techniques for maximizing each of the iPad's most popular features.:; Designed in full-color with an Apple look and feel, and written in a hip,

  3. Pressure ulcers prevention efficacy of an alternating pressure air mattress in elderly patients: E²MAO a randomised study.

    Science.gov (United States)

    Sauvage, P; Touflet, M; Pradere, C; Portalier, F; Michel, J-M; Charru, P; Passadori, Y; Fevrier, R; Hallet-Lezy, A-M; Beauchêne, F; Scherrer, B

    2017-06-02

    Our aim was to compare Axtair One, an alternating pressure air mattress (APAM), with a viscoelastic foam mattress (VFM) in elderly patients at moderate to high risk of developing pressure ulcers (PUs). A randomised, controlled, superiority, parallel-group, open-label, multicentre study, was conducted, between February 2012 and March 2015, in nine French, medium- and long-term stay facilities. Eligible patients were aged 70 and over, had no PUs on enrolment, were bedridden for at least 15 hours per day, had reduced mobility, an absent or minimal positioning capability, a Braden score 12 and a Karnofsky score elderly patients, bedridden for more than 15 hours per day, severely dependent, at moderate-to high-risk of PUs, with an instantaneous risk for the appearance of PUs 7.57 times greater in the VFM group than in the APAM group. This study provides descriptive information and evidence for practice.

  4. Summary and evaluation of low-velocity impact tests of solid steel billet onto concrete pads

    International Nuclear Information System (INIS)

    Witte, M.C.; Hovingh, W.J.; Mok, G.C.; Murty, S.S.; Chen, T.F.; Fischer, L.E.

    1998-02-01

    Spent fuel storage casks intended for use at independent spent fuel storage installations are evaluated during the application and review process for low-velocity impacts representative of possible handling accidents. In the past, the analyses involved in these evaluations have assumed that the casks dropped or tipped onto an unyielding surface - a conservative and simplifying assumption. Since 10 CFR Part 72, the regulation imposed by the Nuclear Regulatory Commission (NRC), does not require this assumption, applicants are currently seeking a more realistic model for the analyses to predict the effect of a cask dropping onto a reinforced concrete pad, including energy absorbing aspects such as cracking and flexure. To develop data suitable for benchmarking these analyses, the NRC has conducted several series of drop-test studies of a solid steel billet and of a near-full-scale empty cask. This report contains a summary and evaluation of all steel billet testing conducted by Sandia National Laboratories and Lawrence Livermore National Laboratory. A series of finite element analyses of the billet testing is described and benchmarked against the test data. A method to apply the benchmarked finite element model of the soil and concrete pad to an analysis of a full-size storage cask is provided. In addition, an application to a open-quotes genericclose quotes full-size cask is presented for side and end drops, and tipover events. The primary purpose of this report is to provide applicants for an NRC license under 10 CFR Part 72 with a method for evaluating storage casks for low-velocity impact conditions

  5. Teaching with iPads

    Science.gov (United States)

    Maj, Hubert

    2015-04-01

    Bilingual students in high school with bilingual units in Boguchwała have received iPads for learning English and a few subjects using CLIL (biology, basics of entrepreneurship, geography, IT and mathematics). Lessons with iPads are interesting for students for several reasons. First of all, teenagers like new technologies and using iPads for teaching helps students to learn by fun. Secondly, iPads give new possibilities of looking for knowledge about each theme. Moreover, teaching with iPads develops students' engagement. They have a chance to choose a few among over 65 000 applications for gathering and then presenting information about the lesson topic. They can easily prepare presentations, movies, cartoons, mind maps or whatever they like. Teaching students, thanks to the iPads, makes it their initiative, and the teacher can inspire them to look for the knowledge rather than disciplining pupils. But teaching with iPads is connected with many problems. For instance, there are not any examples on how to teach using these tools. It is very up-to-date technology and teachers firstly must learn the possibilities of iPads and look for new applications. It takes much time, especially at the beginning, and is difficult especially for inexperienced teachers. In addition, it is almost impossible to maintain control of the iPads for all of the students during the lesson. They can use their iPads for something unconnected with the topic of the lesson. Thirdly is lack of time - active methods (with iPads as well) are more time-consuming and it could be that they do not finish the whole program. And of course the last, but not at least, is the problem of money. Some of the applications must be paid for, and it is usually obligatory to possess a credit card. Fortunately, it is not expensive - applications usually cost a few euros and many of them are free and really good.

  6. iPad colour vision apps for dyschromatopsia screening.

    Science.gov (United States)

    Campbell, Thomas Gordon; Lehn, Alexander; Blum, Stefan; Airey, Caroline; Brown, Helen

    2016-07-01

    Optic neuritis (ON) is a common and important cause of vision loss or vision disturbances in the community, particularly amongst the young, and it is often associated with a persistent dyschromatopsia. Traditionally screening for dyschromatopsia has been carried out using pseudo-isochromatic Ishihara plates. These colour plates were originally developed for testing of colour blindness, and indeed have only more recently been applied to ON. As the Ishihara plate books used for testing are expensive, unwieldy, and are not commonly available in many clinics or wards, many neurologists and ophthalmologists have taken to using untested and unstudied downloadable software packages on portable electronic devices for testing. This study compared the efficacy of printed and iPad (Apple, Cupertino, CA, USA) versions of the Ishihara plates in screening for dyschromatopsia in patients who were suspected of having ON. The main finding was that dyschromatopsia testing using a commercially available application on an iPad was comparable to using the current pragmatic clinical benchmark, the pseudo-isochromatic plates of Ishihara. These findings provide support for the increasingly common practice of screening for dyschromatopsia using the iPad. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Use of an iPad to Provide Warfarin Video Education to Hospitalized Patients.

    Science.gov (United States)

    Kim, Jenny Jane; Mohammad, Rima A; Coley, Kim C; Donihi, Amy C

    2015-09-01

    To evaluate the effectiveness of a warfarin educational video in the hospital setting and to determine patients' satisfaction with using an iPad to view a warfarin educational video. This prospective quality improvement project included adult (≥18 years of age) patients on warfarin in the hospital. All patients completed pre-video and post-video knowledge tests on the iPad before and after viewing the educational video on warfarin therapy. Patients also completed a patient satisfaction survey. Forty hospitalized patients were educated using the warfarin video and included for analysis. The majority of patients were new to warfarin therapy (65%). Forty-three percent of patients passed the pre-video knowledge test, and 90% passed the post-video knowledge test (P iPad and found it easy to use. Patients who were younger (iPad more than older patients (P = 0.01) and male subjects (P = 0.02), respectively. Also, younger patients found the iPad easier to use compared with patients who were older (P = 0.01). Educating hospitalized patients about warfarin by using a video on an iPad was effective. Video education on an iPad may be an alternative to traditional education in the hospital setting.

  8. Quantitative evaluation of the pivot shift by image analysis using the iPad.

    Science.gov (United States)

    Hoshino, Yuichi; Araujo, Paulo; Ahldén, Mattias; Samuelsson, Kristian; Muller, Bart; Hofbauer, Marcus; Wolf, Megan R; Irrgang, James J; Fu, Freddie H; Musahl, Volker

    2013-04-01

    To enable comparison of test results, a widely available measurement system for the pivot shift test is needed. Simple image analysis of lateral knee joint translation is one such system that can be installed on a prevalent computer tablet (e.g. iPad). The purpose of this study was to test a novel iPad application to detect the pivot shift. It was hypothesized that the abnormal lateral translation in ACL deficient knees would be detected by the iPad application. Thirty-four consecutive ACL deficient patients were tested. Three skin markers were attached on the following bony landmarks: (1) Gerdy's tubercle, (2) fibular head and (3) lateral epicondyle. A standardized pivot shift test was performed under anaesthesia, while the lateral side of the knee joint was monitored. The recorded movie was processed by the iPad application to measure the lateral translation of the knee joint. Lateral translation was compared between knees with different pivot shift grades. Valid data sets were obtained in 20 (59 %) ACL deficient knees. The remaining 14 data sets were invalid because of failure to detect translation or detection of excessive translation. ACL deficient knees had larger lateral translation than the contra-lateral knees (p iPad application, the potential of the iPad application to classify the pivot shift was demonstrated.

  9. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart.

    Science.gov (United States)

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials.

  10. Biomechanical Comparison of Shorts With Different Pads

    Science.gov (United States)

    Marcolin, Giuseppe; Petrone, Nicola; Reggiani, Carlo; Panizzolo, Fausto A.; Paoli, Antonio

    2015-01-01

    Abstract An intensive use of the bicycle may increase the risk of erectile dysfunction and the compression of the perineal area has been showed to be a major mechanism leading to sexual alterations compromising the quality of life. Manufacturers claim that pads contribute to increase cyclists perineal protection ensuring a high level of comfort. To investigate the influence of various cycling pads with regard to perineal protection and level of comfort. Nine club road cyclists rode 20 min on a drum simulator, located at the Nutrition and Exercise Physiology Laboratory, at a constant speed and gear ratio wearing the shorts with 3 cycling pads of different design and thickness: basic (BAS), intermediate (INT), and endurance (END). Kinematics and pressure data were recorded at min 5, 15, and 20 of the test using a motion capture system and a pressure sensor mat. The variables of interest were: 3-dimensional pelvis excursions, peak pressure, mean pressure, and vertical force. The comfort level was assessed with a ranking order based on the subjects’ perception after the 20-min trials and measuring the vertical ground reaction force under the anterior wheel as well as the length of the center of pressure (COP) trajectory on the saddle. Results showed that the vertical force and the average value of mean pressure on the saddle significantly decreased during the 20-min period of testing for BAS and END. Mean peak pressure on the corresponding perineal cyclist area significantly increased only for BAS during the 20-min period. Interestingly objective comfort indexes measured did not match cyclists subjective comfort evaluation. The lower capacity of BAS to reduce the peak pressure on the corresponding perineal area after 20 min of testing, together with its positive comfort evaluation, suggest that a balance between protection and perceived comfort should be taken into account in the choice of the pad. Hence, the quantitative approach of objective comfort indexes

  11. Metal-core pad-plane development for ACTAR TPC

    Science.gov (United States)

    Giovinazzo, J.; Pibernat, J.; Goigoux, T.; de Oliveira, R.; Grinyer, G. F.; Huss, C.; Mauss, B.; Pancin, J.; Pedroza, J. L.; Rebii, A.; Roger, T.; Rosier, P.; Saillant, F.; Wittwer, G.

    2018-06-01

    With the recent development of active targets and time projection chambers (ACTAR TPC) as detectors for fundamental nuclear physics experiments, the need arose for charge collection planes with a high density of readout channels. In order to fulfill the mechanical constraints for the ACTAR TPC device, we designed a pad-plane based on a metal-core circuit with an conceptually simple design and routing for signal readout, named FAKIR (in reference to a fakir bed of nails). A test circuit has been equipped with a micro mesh gaseous structure (micromegas) for signal amplification and a dedicated readout electronics. Test measurements have been performed with an 55Fe X-ray source giving an intrinsic energy resolution (FWHM) of 22 ± 1% at 5 . 9 keV, and with a 3-alpha source for which a resolution of about 130 ± 20 keV at 4 . 8 MeV has been estimated. The pad-plane has been mounted into a reduced size demonstrator version of the ACTAR TPC detector, in order to illustrate charged particle track reconstruction. The tests preformed with the X-ray and the 3-alpha sources shows that results obtained from pads signals are comparable to the intrinsic result from the micro-mesh signal. In addition, a simple alpha particle tracks analysis is performed to demonstrate that the pad plane allows a precise reconstruction of the direction and length of the trajectories.

  12. Teach yourself visually iPad

    CERN Document Server

    Hart-Davis, Guy

    2013-01-01

    Fully updated coverage on the latest iPad and iPad mini! As the amazing iPad continues to evolve, so does this invaluable visual guide. Bestselling veteran author Guy Hart-Davis gets you up to date on the latest generation of the iPad, the new iPad Air, as well as the iPad mini with his clear step-by-step, image-driven guidance that is perfectly geared towards those who learn best with visual assistance. You'll get all the latest information for accessing and downloading books, apps, music, and video content as well as sending photos and e-mails, syncing with other devices and services, and

  13. Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients' temperatures in prehospital emergency care - an intervention study.

    Science.gov (United States)

    Aléx, Jonas; Karlsson, Stig; Björnstig, Ulf; Saveman, Britt-Inger

    2015-01-01

    Background The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients' exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients' temperatures in the prehospital emergency care. Methods A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30) was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30) no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS), subjective comments on cold experiences, and finger, ear and air temperatures. Results Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001) but decreased in the control group (p=0.014). A significant higher proportion (57%) of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, pthermal comfort and may prevent the negative consequences of cold stress.

  14. Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients' temperatures in prehospital emergency care--an intervention study.

    Science.gov (United States)

    Aléx, Jonas; Karlsson, Stig; Björnstig, Ulf; Saveman, Britt-Inger

    2015-01-01

    The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients' exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients' temperatures in the prehospital emergency care. A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30) was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30) no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS), subjective comments on cold experiences, and finger, ear and air temperatures. Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001) but decreased in the control group (p=0.014). A significant higher proportion (57%) of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, pthermal comfort and may prevent the negative consequences of cold stress.

  15. Verification of neutron pad and 17 x 7 guide tube designs by preoperational tests on the Trojan I power plant

    International Nuclear Information System (INIS)

    Bloyd, C.N.; Singleton, N.R.; Ciaramitaro, W.

    1976-05-01

    The internals vibration measurement program carried out on the Trojan-1 reactor during preoperational testing is described. The flow induced response of a 17 x 17 guide tube and the neutron pad core barrel were deduced from the plant test data and compared with the expected responses. The results showed good agreement with expected vibration levels

  16. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  17. Accurate micro Hall effect measurements on scribe line pads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Petersen, Dirch Hjorth; Wang, Fei

    2009-01-01

    Hall mobility and sheet carrier density are important parameters to monitor in advanced semiconductor production. If micro Hall effect measurements are done on small pads in scribe lines, these parameters may be measured without using valuable test wafers. We report how Hall mobility can...... be extracted from micro four-point measurements performed on a rectangular pad. The dimension of the investigated pad is 400 × 430 ¿m2, and the probe pitches range from 20 ¿m to 50 ¿m. The Monte Carlo method is used to find the optimal way to perform the Hall measurement and extract Hall mobility most...

  18. iPad 2 Made Simple

    CERN Document Server

    Mazo, Gary; Ritchie, Rene

    2011-01-01

    The iPad 2 is thinner, more powerful, intuitive and very fun for users of all ages. Your iPad can be used for reading, surfing the web, emailing, watching TV and movies, getting work done and much more. And with over 65,000 apps just for the iPad, as well as the ability to run over 30,000 iPhone apps, the possibilities are endless. iPad 2 Made Simple clarifies all of the key features on the iPad, introduces what's new, and also reveals dozens of time-saving shortcuts and techniques. The book has over 1,000 screen shots that are carefully annotated with step-by-step instructions. * Clear instru

  19. Mechanical behaviour of the heel pad: experimental and numerical approach

    DEFF Research Database (Denmark)

    Matteoli, Sara; Fontanella, C. G.; Virga, A.

    The aim of the present work was to investigate the stress relaxation phenomena of the heel pad region under different loading conditions. A 31-year-old healthy female was enrolled in this study and her left foot underwent both MRI and experimental compression tests. Experimental results were...... compared with those obtained from finite element analysis performed on numerical 3D subject-specific heel pad model built on the basis of MRI. The calcaneal fat pad tissue was described with a visco-hyperelastic model, while a fiber-reinforced hyperelastic model was formulated for the skin. The reliability...

  20. 16 CFR 1633.4 - Prototype testing requirements.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Prototype testing requirements. 1633.4... STANDARD FOR THE FLAMMABILITY (OPEN FLAME) OF MATTRESS SETS The Standard § 1633.4 Prototype testing... three specimens of each prototype to be tested according to § 1633.7 and obtain passing test results...

  1. Impact response of US Army and National Football League helmet pad systems

    Energy Technology Data Exchange (ETDEWEB)

    Moss, W C; King, M J

    2011-02-18

    Lawrence Livermore National Laboratory [LLNL] was tasked to compare the impact response of NFL helmet pad systems and U.S. Army pad systems compatible with an Advanced Combat Helmet [ACH] at impact velocities up to 20 ft/s. This was a one-year study funded by the U.S. Army and JIEDDO. The Army/JIEDDO point of contact is COL R. Todd Dombroski, DO, JIEDDO Surgeon. LLNL was chosen by committee to perform the research based on prior published computational studies of the mechanical response of helmets and skulls to blast. Our collaborators include the U.S. Army Aeromedical Research Laboratory [USAARL] (a DoD laboratory responsible for impact testing helmets), Team Wendy and Oregon Aero (current and former ACH pad manufacturers), Riddell and Xenith (NFL pad manufacturers), and d3o (general purpose sports pad manufacturer). The manufacturer-supplied pad systems that were studied are shown in the figure below. The first two are the Army systems, which are bilayer foam pads with both hard and soft foam and a water-resistant airtight wrapper (Team Wendy) or a water-resistant airtight coating (Oregon Aero). The next two are NFL pad systems. The Xenith system consists of a thin foam pad and a hollow air-filled cylinder that elastically buckles under load. The Riddell system is a bilayer foam pad that is encased in an inflatable airbag with relief channels to neighboring pads in the helmet. The inflatable airbag is for comfort and provides no enhancement to impact mitigation. The d3o system consists of a rate-sensitive homogeneous dense foam. LLNL performed experiments to characterize the material properties of the individual foam materials and the response of the complete pad systems, to obtain parameters needed for the simulations. LLNL also performed X-ray CT scans of an ACH helmet shell that were used to construct a geometrically accurate computational model of the helmet. Two complementary sets of simulations were performed. The first set of simulations reproduced the

  2. 75 FR 24572 - Foreign-Trade Zone 29 - Louisville, Kentucky, Application for Subzone, Louisville Bedding Company...

    Science.gov (United States)

    2010-05-05

    ... - Louisville, Kentucky, Application for Subzone, Louisville Bedding Company (Household Bedding Products...-purpose subzone status for the bedding products manufacturing facilities of Louisville Bedding Company... facilities are used to manufacture household bedding products, including mattress pads and pillows (up to 10...

  3. Treating P.A.D.

    Science.gov (United States)

    ... Issue Past Issues Special Section Treating P.A.D. Past Issues / Summer 2008 Table of Contents For ... Illustration courtesy of NHLBI Treatment for P.A.D. is designed to reduce a patient's symptoms, prevent ...

  4. Toxicity and mutagenicity of low-metallic automotive brake pad materials.

    Science.gov (United States)

    Malachova, Katerina; Kukutschova, Jana; Rybkova, Zuzana; Sezimova, Hana; Placha, Daniela; Cabanova, Kristina; Filip, Peter

    2016-09-01

    Organic friction materials are standardly used in brakes of small planes, railroad vehicles, trucks and passenger cars. The growing transportation sector requires a better understanding of the negative impact related to the release of potentially hazardous materials into the environment. This includes brakes which can release enormous quantities of wear particulates. This paper addresses in vitro detection of toxic and mutagenic potency of one model and two commercially available low-metallic automotive brake pads used in passenger cars sold in the EU market. The model pad made in the laboratory was also subjected to a standardized brake dynamometer test and the generated non-airborne wear particles were also investigated. Qualitative "organic composition" was determined by GC/MS screening of dichloromethane extracts. Acute toxicity and mutagenicity of four investigated sample types were assessed in vitro by bioluminescence assay using marine bacteria Vibrio fischeri and by two bacterial bioassays i) Ames test on Salmonella typhimurium His(-) and ii) SOS Chromotest using Escherichia coli PQ37 strain. Screening of organic composition revealed a high variety of organic compounds present in the initial brake pads and also in the generated non-airborne wear debris. Several detected compounds are classified by IARC as possibly carcinogenic to humans, e. g. benzene derivatives. Acute toxicity bioassay revealed a response of bacterial cells after exposure to all samples used. Phenolic resin and wear debris were found to be acutely toxic; however in term of mutagenicity the response was negative. All non-friction exposed brake pad samples (a model pad and two commercial pad samples) were mutagenic with metabolic activation in vitro. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Functionally different pads on the same foot allow control of attachment: stick insects have load-sensitive "heel" pads for friction and shear-sensitive "toe" pads for adhesion.

    Directory of Open Access Journals (Sweden)

    David Labonte

    Full Text Available Stick insects (Carausius morosus have two distinct types of attachment pad per leg, tarsal "heel" pads (euplantulae and a pre-tarsal "toe" pad (arolium. Here we show that these two pad types are specialised for fundamentally different functions. When standing upright, stick insects rested on their proximal euplantulae, while arolia were the only pads in surface contact when hanging upside down. Single-pad force measurements showed that the adhesion of euplantulae was extremely small, but friction forces strongly increased with normal load and coefficients of friction were [Formula: see text] 1. The pre-tarsal arolium, in contrast, generated adhesion that strongly increased with pulling forces, allowing adhesion to be activated and deactivated by shear forces, which can be produced actively, or passively as a result of the insects' sprawled posture. The shear-sensitivity of the arolium was present even when corrected for contact area, and was independent of normal preloads covering nearly an order of magnitude. Attachment of both heel and toe pads is thus activated partly by the forces that arise passively in the situations in which they are used by the insects, ensuring safe attachment. Our results suggest that stick insect euplantulae are specialised "friction pads" that produce traction when pressed against the substrate, while arolia are "true" adhesive pads that stick to the substrate when activated by pulling forces.

  6. Investigation on the load-deformation curves of a human healthy heel pad

    DEFF Research Database (Denmark)

    Fontanella, C. G.; Matteoli, Sara; Carniel, E.L.

    2012-01-01

    The aims of the present work were to build a 3D subject-specific heel pad model based on the anatomy revealed by MR imaging of a subject's heel pad, and to compare the load–displacement responses obtained from this model with those obtained from a compression device used on the subject's heel pad....... A 30 year-old European healthy female (mass=54kg, height=165cm) was enrolled in this study. Her left foot underwent both MRI and compression tests. A numerical model of the heel region was developed based on a 3D CAD solid model obtained by MR images. The calcaneal fat pad tissue was described...... with a visco-hyperelastic model, while a fiber-reinforced hyperelastic model was formulated for the skin. Numerical analyses were performed to interpret the mechanical response of heel tissues. Different loading conditions were assumed according to experimental tests. The heel tissues showed a non-linear visco...

  7. A Randomized, Crossover Trial of a Novel Sound-to-Sleep Mattress Technology in Children with Autism and Sleep Difficulties.

    Science.gov (United States)

    Frazier, Thomas W; Krishna, Jyoti; Klingemier, Eric; Beukemann, Mary; Nawabit, Rawan; Ibrahim, Sally

    2017-01-15

    This preliminary study investigated the tolerability and efficacy of a novel mattress technology-the Sound-To-Sleep (STS) system-in the treatment of sleep problems in children with autism. After screening, 45 children, ages 2.5 to 12.9 years, were randomized to order of mattress technology use (On-Off vs. Off-On). Treatment conditions (On vs. Off) lasted two weeks with immediate crossover. Tolerability, including study discontinuation and parent-report of mattress tolerance and ease of use, was tracked throughout the study. Efficacy assessments were obtained at baseline, prior to crossover, and end of study and included measures of autism traits, other psychopathology symptoms, sensory abnormalities, communication difficulties, quality of life, sleep diary parameters, and single-blinded actigraphy-derived sleep parameters. Statistical analyses evaluated differences in tolerability and efficacy when the STS system was on versus off. STS system use was well tolerated (n = 2, 4.4% dropout) and resulted in parent-reported sleep quality improvements (STS off mean = 4.3, 95% CI = 4.05-4.54 vs. on mean = 4.9, 95%CI = 4.67-5.14). The technology was described by parents as very easy to use and child tolerance was rated as good. Parent-diary outcomes indicated improvements in falling asleep and reduced daytime challenging behavior. Actigraphy-derived sleep parameters indicated improved sleep duration and sleep efficiency. Improvements in child and family quality of life were identified on parent questionnaires. A future large sample phase 2 trial of the STS system is warranted and would benefit from extended study duration, an objective primary efficacy outcome, and careful attention to methodological issues that promote compliance with the intervention and study procedures. © 2017 American Academy of Sleep Medicine

  8. iPad for digital photographers

    CERN Document Server

    Story, Derrick

    2013-01-01

    Discover innovative ways to strengthen your photography business with your iPad Many photographers are turning to the flexible, easy-to-use tools of the iPad and relying on them to wear a variety of hats in their photography business. Whether portable portfolio, editing tool, payment-tracking system, or appointment calendar, the iPad melds together the best attributes of the cell phone and a laptop computer and this unique book highlights them all. With this helpful resource, you'll learn how to get the most out of your iPad to not only improve your business but also enhance your p

  9. Comfort zone-design free stalls: do they influence the stall use behavior of lame cows?

    Science.gov (United States)

    Cook, N B; Marin, M J; Mentink, R L; Bennett, T B; Schaefer, M J

    2008-12-01

    The behavior of 59 cows in 4 herds, each with Comfort Zone-design free stalls with dimensions suitable for 700-kg, mature Holstein dairy cows, was filmed for a 48-h period. Comparison was made between nonlame, slightly lame, and moderately lame cows on either rubber-crumb-filled mattress stall surfaces bedded with a small amount of sawdust (2 herds) or a Pack Mat design, which consisted of a rubber-crumb-filled mattress pad installed 5 cm below a raised rear curb, bedded with 5 to 8 cm of sand bedding (2 herds). All other stall design components were similar. Despite adequate resting space and freedom to perform normal rising and lying movements, lame cows on mattresses stood in the stall for >2 h longer than nonlame cows. Although a significant increase in stall standing behavior was observed in lame cows on Pack Mat stalls, the mean (95% confidence interval) standing time in the stall was only 0.7 (0 to 3.0) h/d for nonlame cows and 1.6 (0 to 4.2) h/d for moderately lame cows, which was less than the 2.1 (0 to 4.4), 4.3 (1.6 to 6.9), and 4.9 (2.5 to 7.3) h/d spent standing in the stall for nonlame, slightly lame, and moderately lame cows on mattresses, respectively. This observation supports the hypothesis that it is the nature of the stall surface that dictates changes in stall standing behavior observed in lame cows, rather than other components of stall design. The finding that only 5 to 8 cm of sand over a mattress pad provides most of the benefits of deep sand-bedded stalls, along with other advantages related to stall maintenance and manure handling, gives farmers another useful housing alternative with which to improve cow comfort and well-being.

  10. Corrective Action Decision Document for Corrective Action Unit 224: Decon Pad and Septic Systems Nevada Test Site, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    David A. Strand

    2005-05-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 224, Decon Pad and Septic Systems, in Areas 2, 3, 5, 6, 11, and 23 of the Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 224 is comprised of the following corrective action sites (CASs): (1) 02-04-01, Septic Tank (Buried); (2) 03-05-01, Leachfield; (3) 05-04-01, Septic Tanks (4)/Discharge Area; (4) 06-03-01, Sewage Lagoons (3); (5) 06-05-01, Leachfield; (6) 06-17-04, Decon Pad and Wastewater Catch; (7) 06-23-01, Decon Pad Discharge Piping; (8) 11-04-01, Sewage Lagoon; and (9) 23-05-02, Leachfield. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for the nine CASs within CAU 224. Corrective action investigation activities were performed from August 10, 2004, through January 18, 2005, as set forth in the CAU 224 Corrective Action Investigation Plan.

  11. Design of a Novel Flexible Capacitive Sensing Mattress for Monitoring Sleeping Respiratory

    Directory of Open Access Journals (Sweden)

    Wen-Ying Chang

    2014-11-01

    Full Text Available In this paper, an algorithm to extract respiration signals using a flexible projected capacitive sensing mattress (FPCSM designed for personal health assessment is proposed. Unlike the interfaces of conventional measurement systems for poly-somnography (PSG and other alternative contemporary systems, the proposed FPCSM uses projected capacitive sensing capability that is not worn or attached to the body. The FPCSM is composed of a multi-electrode sensor array that can not only observe gestures and motion behaviors, but also enables the FPCSM to function as a respiration monitor during sleep using the proposed approach. To improve long-term monitoring when body movement is possible, the FPCSM enables the selection of data from the sensing array, and the FPCSM methodology selects the electrodes with the optimal signals after the application of a channel reduction algorithm that counts the reversals in the capacitive sensing signals as a quality indicator. The simple algorithm is implemented in the time domain. The FPCSM system is used in experimental tests and is simultaneously compared with a commercial PSG system for verification. Multiple synchronous measurements are performed from different locations of body contact, and parallel data sets are collected. The experimental comparison yields a correlation coefficient of 0.88 between FPCSM and PSG, demonstrating the feasibility of the system design.

  12. Proof Pad: A New Development Environment for ACL2

    Directory of Open Access Journals (Sweden)

    Caleb Eggensperger

    2013-04-01

    Full Text Available Most software development projects rely on Integrated Development Environments (IDEs based on the desktop paradigm, with an interactive, mouse-driven user interface. The standard installation of ACL2, on the other hand, is designed to work closely with Emacs. ACL2 experts, on the whole, like this mode of operation, but students and other new programmers who have learned to program with desktop IDEs often react negatively to the process of adapting to an unfamiliar form of interaction. This paper discusses Proof Pad, a new IDE for ACL2. Proof Pad is not the only attempt to provide ACL2 IDEs catering to students and beginning programmers. The ACL2 Sedan and DrACuLa systems arose from similar motivations. Proof Pad builds on the work of those systems, while also taking into account the unique workflow of the ACL2 theorem proving system. The design of Proof Pad incorporated user feedback from the outset, and that process continued through all stages of development. Feedback took the form of direct observation of users interacting with the IDE as well as questionnaires completed by users of Proof Pad and other ACL2 IDEs. The result is a streamlined interface and fast, responsive system that supports using ACL2 as a programming language and a theorem proving system. Proof Pad also provides a property-based testing environment with random data generation and automated interpretation of properties as ACL2 theorem definitions.

  13. Shock absorbency of factors in the shoe/heel interaction--with special focus on role of the heel pad.

    Science.gov (United States)

    Jørgensen, U; Bojsen-Møller, F

    1989-06-01

    The heel pad acts as a shock absorber in walking and in heel-strike running. In some patients, a reduction of its shock-absorbing capacity has been connected to the development of overuse injuries. In this article, the shock absorption of the heel pad as well as external shock absorbers are studied. Individual variation and the effect of trauma and confinement on the heel pad were specifically investigated. Drop tests, imitating heel impacts, were performed on a force plate. The test specimens were cadaver heel pads (n = 10); the shoe sole component consisted of ethyl vinyl acetate (EVA) foam and Sorbothane inserts. The shock absorption was significantly greater in the heel pad than in the external shock absorbers. The mean heel pad shock absorption was 1.1 times for EVA foam and 2.1 times for Sorbothane. The shock absorption varied by as much as 100% between heel pads. Trauma caused a decrease in the heel pad shock absorbency (24%), whereas heel pad confinement increased the shock absorbency (49% in traumatized heel pads and 29.5% in nontraumatized heel pads). These findings provide a biomechanical rationale for the clinical observations of a correlation between heel pad shock absorbency loss and heel strike-dependent overuse injuries. To increase shock absorbency, confinement of the heel pad should be attempted in vivo.

  14. iPad mini for dummies

    CERN Document Server

    Baig, Edward C

    2014-01-01

    Find out why the iPad mini has never been bigger This new edition of iPad mini For Dummies covers all the latest tips and tricks for getting an even bigger bang out of your iPad mini. Presented in full-color and written in the straightforward but fun language that has defined the For Dummies brand for more than twenty years, this friendly guide walks you through the multitouch interface, going online, getting connected, packing your iPad mini with apps, games, e-books, photos, music, and movies, synchronizing your data, texting with iMessage, working with Siri, importing pictures and launching

  15. Beginning iPad Application Development

    CERN Document Server

    Lee, Wei-Meng

    2010-01-01

    A hands-on approach to iPad application development. Beginning iPad Application Development is written to help jumpstart beginning iPad developers. It covers the various topics in such a manner that you will progressively learn without being overwhelmed by the details. It adopts the philosophy that the best way to learn is by doing, hence the numerous Try It Out sections in all the chapters, which first show you how to build something and then explain how things work. Although iPad programming is a huge topic, the aim for this book is to get you started with the fundamentals, and help you unde

  16. iPad & Siri for dummies

    CERN Document Server

    Baig, Edward C

    2012-01-01

    Two complete e-books on using iPad and Siri for one low price! This unique value-priced e-book set brings together two bestselling For Dummies books in a single e-book file. Including a comprehensive table of contents and the full text of each book, complete with cover, this e-book set helps you get the most out of your iPad and Siri, its artificial intelligence personal assistant. Best of all, you'll pay less than the cost of each book purchased separately. You'll get the complete text of: iPad For Dummies, which helps you toSet up your iPad, browse the

  17. Internal strain estimation for quantification of human heel pad elastic modulus: A phantom study

    DEFF Research Database (Denmark)

    Holst, Karen; Liebgott, Hervé; Wilhjelm, Jens E.

    2013-01-01

    Shock absorption is the most important function of the human heel pad. However, changes in heel pad elasticity, as seen in e.g. long-distance runners, diabetes patients, and victims of Falanga torture are affecting this function, often in a painful manner. Assessment of heel pad elasticity...... is usually based on one or a few strain measurements obtained by an external load-deformation system. The aim of this study was to develop a technique for quantitative measurements of heel pad elastic modulus based on several internal strain measures from within the heel pad by use of ultrasound images. Nine...... heel phantoms were manufactured featuring a combination of three heel pad stiffnesses and three heel pad thicknesses to model the normal human variation. Each phantom was tested in an indentation system comprising a 7MHz linear array ultrasound transducer, working as the indentor, and a connected load...

  18. Next Generation Non-particulate Dry Nonwoven Pad for Chemical Warfare Agent Decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Ramkumar, S S; Love, A; Sata, U R; Koester, C J; Smith, W J; Keating, G A; Hobbs, L; Cox, S B; Lagna, W M; Kendall, R J

    2008-05-01

    New, non-particulate decontamination materials promise to reduce both military and civilian casualties by enabling individuals to decontaminate themselves and their equipment within minutes of exposure to chemical warfare agents or other toxic materials. One of the most promising new materials has been developed using a needlepunching nonwoven process to construct a novel and non-particulate composite fabric of multiple layers, including an inner layer of activated carbon fabric, which is well-suited for the decontamination of both personnel and equipment. This paper describes the development of a composite nonwoven pad and compares efficacy test results for this pad with results from testing other decontamination systems. The efficacy of the dry nonwoven fabric pad was demonstrated specifically for decontamination of the chemical warfare blister agent bis(2-chloroethyl)sulfide (H or sulfur mustard). GC/MS results indicate that the composite fabric was capable of significantly reducing the vapor hazard from mustard liquid absorbed into the nonwoven dry fabric pad. The mustard adsorption efficiency of the nonwoven pad was significantly higher than particulate activated carbon (p=0.041) and was similar to the currently fielded US military M291 kit (p=0.952). The nonwoven pad has several advantages over other materials, especially its non-particulate, yet flexible, construction. This composite fabric was also shown to be chemically compatible with potential toxic and hazardous liquids, which span a range of hydrophilic and hydrophobic chemicals, including a concentrated acid, an organic solvent and a mild oxidant, bleach.

  19. Activation of PAD4 in NET formation

    Directory of Open Access Journals (Sweden)

    Amanda eRohrbach

    2012-11-01

    Full Text Available Peptidyl arginine deiminases, or PADs, convert arginine residues to the non-ribosomally encoded amino acid citrulline in a variety of protein substrates. PAD4 is expressed in granulocytes and is essential for the formation of neutrophil extracellular traps (NETs via PAD4-mediated histone citrullination. Citrullination of histones is thought to promote NET formation by inducing chromatin decondensation and facilitating the expulsion of chromosomal DNA that is coated with antimicrobial molecules. Numerous stimuli have been reported to lead to PAD4 activation and NET formation. However, how this signaling process proceeds and how PAD4 becomes activated in cells is largely unknown. Herein, we describe the various stimuli and signaling pathways that have been implicated in PAD4 activation and NET formation, including the role of reactive oxygen species generation. To provide a foundation for the above discussion, we first describe PAD4 structure and function, and how these studies led to the development of PAD-specific inhibitors. A comprehensive survey of the receptors and signaling pathways that regulate PAD4 activation will be important for our understanding of innate immunity, and the identification of signaling intermediates in PAD4 activation may also lead to the generation of pharmaceuticals to target NET-related pathogenesis.

  20. University staff adoption of iPads: An empirical study using an extended TAM model

    Directory of Open Access Journals (Sweden)

    Michael Steven Lane

    2014-11-01

    Full Text Available This research examined key factors influencing adoption of iPads by university staff. An online survey collected quantitative data to test hypothesised relationships in an extended TAM model. The findings show that university staff consider iPads easy to use and useful, with a high level of compatibility with their work. Social status had no influence on their attitude to using an iPad. However older university staff and university staff with no previous experience in using a similar technology such as an iPhone or smartphone found iPads less easy to use. Furthermore, a lack of formal end user ICT support impacted negatively on the use of iPads.

  1. Increased Skin Dose With the Use of a Custom Mattress for Prone Breast Radiotherapy

    International Nuclear Information System (INIS)

    Becker, Stewart J.; Patel, Rakesh R.; Mackie, Thomas R.

    2007-01-01

    The purpose of this study was to measure and compare the loss of buildup to the skin of the breast in the prone position due to 2 different positioning systems during tangential external beam irradiation. Two experiments were performed; one with a standard nylon-covered foam support and another with a novel helium-filled Mylar bag support. The choice of helium-filled Mylar was to reduce the contamination to as low as possible. The experiments were designed to allow a surface dose measurement and a depth dose profile with the pads placed in the path of the beam in front of the detector. All measurements were taken using a Capintec PS-033 thin-window parallel plate ionization chamber. The standard nylon-covered foam pad caused the surface dose to rise as it got closer to the skin. When the pad was directly touching the surface, the surface dose increased by 300% compared to the result when no pad was present. This loss of buildup to the surface was similar to that of a custom bolus material. The opposite effect occurred with the use of the helium-filled Mylar bag, namely the surface dose gradually decreased as the pad got closer to the phantom. When the Mylar pad was directly touching the phantom, the surface dose was decreased by 7% compared to when no pad was present. The use of a foam pad could potentially result in a significant higher dose to the skin, resulting in an enhanced acute skin reaction. Therefore, special care should be taken in this clinical scenario and further investigation of an air- or helium-based mylar support pad should be investigated in the context of definitive breast radiation treatment

  2. Significance of heel pad confinement for the shock absorption at heel strike.

    Science.gov (United States)

    Jørgensen, U; Ekstrand, J

    1988-12-01

    Shock absorption (SA) is a simple way to reduce the body load and can be used in the prevention and treatment of injuries. The heel pad is the most important shock absorber in the shoe heel complex. The purpose of this study was to investigate whether the SA at heel strike can be increased by heel support in people and shoes with high or low SA. The impact forces at heel strike were measured on an AMTI (R) force platform. Fourteen legs were tested in seven persons (nine with normal and five with low heel pad SA) in gait analysis and in human drop tests. The tests were performed barefooted, and in a soccer and a running shoe (selected by shoe drop test), with and without the distal 2 cm of the heel counter. The heel pad confinement produced by the heel counter (the heel counter effect) increased the SA in both shoe types significantly in both impact situations. The mean increase in SA was 8.8% (range 5.8%-15.5%). The heel counter effect was in all situations significantly higher in persons with low heel pad shock absorbency (LHPSA) than in those with normal heel pads. The barefoot impact peak force per kg body weight was significantly higher (6% mean) on the side with LHPSA. The running shoe provided the significantly greatest SA compared with the soccer shoe. It is concluded that the shock absorbency at heel strike can be increased significantly by heel support, with highest effect in persons with LHPSA, both in shoes with high and low SA.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Lutte chimique contre les acariens de la poussière de maison

    NARCIS (Netherlands)

    Saint Georges Gridelet, de D.M.O.G.; Kniest, F.M.; Schober, G.; Penaud, A.; Bronswijk, van J.E.M.H.

    1988-01-01

    Chemical control is one of the possibilities for home sanitation for house-dust allergic patients. The causative mites may be found in mattress, padded furniture, curtains, carpets or on walls. Eight different control formulations are available in Europe : Acardust (aerosol), Acarosan (foam and wet

  4. On the comparison between MRI and US imaging for human heel pad thickness measurements

    DEFF Research Database (Denmark)

    Matteoli, Sara; Corbin, Nadège Corbin; Wilhjelm, Jens E.

    2011-01-01

    The human heel pad thickness, defined as the shortest distance between the calcaneus and heel skin, is one of the intrinsic factor which must be taken into account when investigating the biomechanics of the heel pad. US and MRI are the preferable imaging modalities used to measure the heel pad...... thickness as they are both ionizing-free radiations. The aim of this paper is to measure the bone to skin distance of nine heel pad phantoms from MRI and US images, and to compare the results with a true value (TV) in order to find the errors. Paired sample t-test was used to compare the measurements......1530 (P-value=0.402). Results confirm the necessity to investigate on the real speed of sound for the heel pad tissues, in order to have realistic measurements when dealing with human heel pads. __________________________________________________________________________________________________________...

  5. Experienced iPad-Using Early Childhood Teachers: Practices in the One-to-One iPad Classroom

    Science.gov (United States)

    Lu, Ya-Huei; Ottenbreit-Leftwich, Anne T.; Ding, Ai-Chu; Glazewski, Krista

    2017-01-01

    Although many elementary schools have adopted one-to-one programs, we still lack information on how teachers integrate iPads or other tablets into their daily instruction, especially in early childhood settings. The purpose of this case study was to present how four experienced iPad-using early childhood teachers integrated one-to-one iPads into…

  6. Recent Results from Beam Tests of 3D and Pad pCVD Diamond Detectors

    CERN Document Server

    Wallny, Rainer

    2017-01-01

    Results from prototypes of a detector using chemical vapor deposited (CVD) diamond with embedded resistive electrodes in the bulk forming a 3D diamond device are presented. A detector system consisting of 3D devices based on poly-crystalline CVD (pCVD) diamond was connected to a multi-channel readout and successfully tested in a 120 GeV/c proton beam at CERN proving for the first time the feasibility of the 3D detector concept in pCVD for particle tracking applications. We also present beam test results on the dependence of signal size on incident particle rate in charged particle detectors based on poly-crystalline CVD diamond. The detectors were tested in a 260 MeV/c pion beam over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2 . The pulse height of the sensors was measured with pad readout electronics at a peaking time of 7 ns. Our data from the 2015 beam tests at PSI indicate that the pulse height of poly-crystalline CVD diamond sensor irradiated to 5×1014 neq/cm2 is independent of particle flux...

  7. Towards reducing impact-induced brain injury: lessons from a computational study of army and football helmet pads.

    Science.gov (United States)

    Moss, William C; King, Michael J; Blackman, Eric G

    2014-01-01

    We use computational simulations to compare the impact response of different football and U.S. Army helmet pad materials. We conduct experiments to characterise the material response of different helmet pads. We simulate experimental helmet impact tests performed by the U.S. Army to validate our methods. We then simulate a cylindrical impactor striking different pads. The acceleration history of the impactor is used to calculate the head injury criterion for each pad. We conduct sensitivity studies exploring the effects of pad composition, geometry and material stiffness. We find that (1) the football pad materials do not outperform the currently used military pad material in militarily relevant impact scenarios; (2) optimal material properties for a pad depend on impact energy and (3) thicker pads perform better at all velocities. Although we considered only the isolated response of pad materials, not entire helmet systems, our analysis suggests that by using larger helmet shells with correspondingly thicker pads, impact-induced traumatic brain injury may be reduced.

  8. iPad for the Older and Wiser Get Up and Running Safely and Quickly with the Apple iPad

    CERN Document Server

    McManus, Sean

    2011-01-01

    Easy-to-follow, friendly advice on using the iPad 2 This heavily illustrated, approachable guide for the anyone over 50 provides a solid resource for learning how to use the iPad in everyday situations. Veteran author and technology expert Sean McManus clearly explains how to use the iPad to send e-mails, listen to music, watch movies, and play games. Detailed coverage walks you step by step through setting up and registering your iPad, connecting to the Internet, syncing your iPad to other devices, and much more. The iPad is an ideal companion for making your life easier, and this friendly gu

  9. iPads og undervisningsdifferentiering

    DEFF Research Database (Denmark)

    Lorentzen, Rasmus Fink

    2013-01-01

    Artiklen er blevet til på baggrund af udviklingsprojektet med iPad i Odder Kommune. Den generaliserer på baggrund af en række eksempler herfra og peger på at med iPad'en drejer det sig om at udnytte mulighederne for at lade eleverne arbejde producerende, kollaborativt og fagligt meningsfuldt...

  10. Design of a thermal waist-pad

    Science.gov (United States)

    Kursun Bahadir, S.; Sahin, U. K.; Acikgoz Tufan, H.

    2017-10-01

    The objective of the current study is designing a thermal waist-pad for people who have backaches with a sandwich-like multi-layered structure. Two model is developed; one is three-layered and second is five-layered with waterproof woven outer layer fabric, Thermolite® knitted fabric (for five-layered structures), wool knitted, polyester nonwoven fabric, polypropylene nonwoven fabric and viscose nonwoven fabric for mid-layer. 10 different structures are designed and produced. All samples are tested for thermal comfort properties of waist-pad. Multi-layer structures were tested, and according to their thermal performance and thermal comfort criteria, all results are evaluated for identifying the best product. These three factors are examined by analysis of thermal conductivity, thermal resistance, thermal absorptivity, relative water vapour/air permeability, water absorption. Highest thermal resistance test result, 150,42 mK/Wm2, is achieved in five-layered sandwich structure with waterproof fabric, Thermolite® fabric, wool based knitted fabric, Thermolite® fabric and waterproof fabric, respectively. Thermal conductivity result of this structure is 46,2 mW/mK, which is one of the lowest results among the alternative structures. Structures with Thermolite® fabric show higher thermal comfort when compared to others.

  11. performance evaluation of a composite-padded evaporative cooling

    African Journals Online (AJOL)

    user

    average temperature drop and saturation efficiency in the evaporative cooler during the no-load test were 5°C and 42%, ... flow rate wetting the pad and the construction material .... principle of evaporation which results in a cooling effect.

  12. 21 CFR 878.4440 - Eye pad.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  13. iPad all-in-one for dummies

    CERN Document Server

    Muir, Nancy C

    2012-01-01

    Six minibooks in one show you how to power-use the iPad For work, play, and life on the road, the iPad has quickly become indispensable, and the new iPad is packed with even more features and power than ever. In this fun and practical guide, long-time For Dummies author Nancy C. Muir walks you through the latest functions, features, and capabilities of the iPad. Get up to speed on the basics, see how to use your iPad to get more organized and productive, learn to use your iPad for work, and discover all the ways to have fun. This book covers it all, and in full color! Packs six minibooks in on

  14. Cosmological applications of Padé approximant

    International Nuclear Information System (INIS)

    Wei, Hao; Yan, Xiao-Peng; Zhou, Ya-Nan

    2014-01-01

    As is well known, in mathematics, any function could be approximated by the Padé approximant. The Padé approximant is the best approximation of a function by a rational function of given order. In fact, the Padé approximant often gives better approximation of the function than truncating its Taylor series, and it may still work where the Taylor series does not converge. In the present work, we consider the Padé approximant in two issues. First, we obtain the analytical approximation of the luminosity distance for the flat XCDM model, and find that the relative error is fairly small. Second, we propose several parameterizations for the equation-of-state parameter (EoS) of dark energy based on the Padé approximant. They are well motivated from the mathematical and physical points of view. We confront these EoS parameterizations with the latest observational data, and find that they can work well. In these practices, we show that the Padé approximant could be an useful tool in cosmology, and it deserves further investigation

  15. Cosmological applications of Padé approximant

    Science.gov (United States)

    Wei, Hao; Yan, Xiao-Peng; Zhou, Ya-Nan

    2014-01-01

    As is well known, in mathematics, any function could be approximated by the Padé approximant. The Padé approximant is the best approximation of a function by a rational function of given order. In fact, the Padé approximant often gives better approximation of the function than truncating its Taylor series, and it may still work where the Taylor series does not converge. In the present work, we consider the Padé approximant in two issues. First, we obtain the analytical approximation of the luminosity distance for the flat XCDM model, and find that the relative error is fairly small. Second, we propose several parameterizations for the equation-of-state parameter (EoS) of dark energy based on the Padé approximant. They are well motivated from the mathematical and physical points of view. We confront these EoS parameterizations with the latest observational data, and find that they can work well. In these practices, we show that the Padé approximant could be an useful tool in cosmology, and it deserves further investigation.

  16. MuPAD tutorial

    CERN Document Server

    Creutzig, Christopher

    2004-01-01

    This book explains the basic use of the software package called MuPAD and gives an insight into the power of the system. MuPAD is a so-called com­ puter algebra system, which is developed mainly by Sciface Software and the MuPAD Research Group of the University of Paderborn in Germany. This introduction addresses mathematicians, engineers, computer scientists, natural scientists and, more generally, all those in need of mathematical com­ putations for their education or their profession. Generally speaking, this book addresses anybody who wants to use the power of a modern computer algebra package. There are two ways to use a computer algebra system. On the one hand, you may use the mathematical knowledge it incorporates by calling system functions interactively. For example, you can compute symbolic integrals or generate and invert matrices by calling appropriate functions. They comprise the system's mathematical intelligence and may implement sophisticated al­ gorithms. Chapters 2 through 15 discuss this...

  17. Monte-Carlo Simulation and Automated Test Bench for Developing a Multichannel NIR-Based Vital-Signs Monitor.

    Science.gov (United States)

    Bruser, Christoph; Strutz, Nils; Winter, Stefan; Leonhardt, Steffen; Walter, Marian

    2015-06-01

    Unobtrusive, long-term monitoring of cardiac (and respiratory) rhythms using only non-invasive vibration sensors mounted in beds promises to unlock new applications in home and low acuity monitoring. This paper presents a novel concept for such a system based on an array of near infrared (NIR) sensors placed underneath a regular bed mattress. We focus on modeling and analyzing the underlying technical measurement principle with the help of a 2D model of a polyurethane foam mattress and Monte-Carlo simulations of the opto-mechanical interaction responsible for signal genesis. Furthermore, a test rig to automatically and repeatably impress mechanical vibrations onto a mattress is introduced and used to identify the properties of a prototype implementation of the proposed measurement principle. Results show that NIR-based sensing is capable of registering miniscule deformations of the mattress with a high spatial specificity. As a final outlook, proof-of-concept measurements with the sensor array are presented which demonstrate that cardiorespiratory movements of the body can be detected and that automatic heart rate estimation at competitive error levels is feasible with the proposed approach.

  18. Optimal Padding for the Two-Dimensional Fast Fourier Transform

    Science.gov (United States)

    Dean, Bruce H.; Aronstein, David L.; Smith, Jeffrey S.

    2011-01-01

    One-dimensional Fast Fourier Transform (FFT) operations work fastest on grids whose size is divisible by a power of two. Because of this, padding grids (that are not already sized to a power of two) so that their size is the next highest power of two can speed up operations. While this works well for one-dimensional grids, it does not work well for two-dimensional grids. For a two-dimensional grid, there are certain pad sizes that work better than others. Therefore, the need exists to generalize a strategy for determining optimal pad sizes. There are three steps in the FFT algorithm. The first is to perform a one-dimensional transform on each row in the grid. The second step is to transpose the resulting matrix. The third step is to perform a one-dimensional transform on each row in the resulting grid. Steps one and three both benefit from padding the row to the next highest power of two, but the second step needs a novel approach. An algorithm was developed that struck a balance between optimizing the grid pad size with prime factors that are small (which are optimal for one-dimensional operations), and with prime factors that are large (which are optimal for two-dimensional operations). This algorithm optimizes based on average run times, and is not fine-tuned for any specific application. It increases the amount of times that processor-requested data is found in the set-associative processor cache. Cache retrievals are 4-10 times faster than conventional memory retrievals. The tested implementation of the algorithm resulted in faster execution times on all platforms tested, but with varying sized grids. This is because various computer architectures process commands differently. The test grid was 512 512. Using a 540 540 grid on a Pentium V processor, the code ran 30 percent faster. On a PowerPC, a 256x256 grid worked best. A Core2Duo computer preferred either a 1040x1040 (15 percent faster) or a 1008x1008 (30 percent faster) grid. There are many industries that

  19. Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients’ temperatures in prehospital emergency care – an intervention study

    Directory of Open Access Journals (Sweden)

    Jonas Aléx

    2015-09-01

    Full Text Available Background: The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients’ exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients’ temperatures in the prehospital emergency care. Methods: A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30 was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30 no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS, subjective comments on cold experiences, and finger, ear and air temperatures. Results: Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001 but decreased in the control group (p=0.014. A significant higher proportion (57% of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, p<0.001. At arrival, finger, ear and compartment air temperature showed no statistical significant difference between groups. Mean transport time was approximately 15 minutes. Conclusions: The use of active heat from underneath increases the patients’ thermal comfort and may prevent the negative consequences of cold stress.

  20. Thermal Characterisation of Brake Pads

    DEFF Research Database (Denmark)

    Ramousse, Séverine; Høj, Jakob Weiland; Sørensen, O. T.

    2001-01-01

    The chemical-physical decomposition processes that occur in a brake pad heated to 1000degreesC have been studied. This temperature can be reached when a brake pad is applied. Thermogravimetry and differential thermal analysis were used in combination with evolved gas analysis, and image analysis...... using a scanning electron microscope.A brake pad is essentially a mixture of iron, carbon and binder. Combined techniques have been used, because of chemical reaction overlap, to determine how and at what temperature the binder decomposes, the coal and graphite combust and the iron oxidises.This work...

  1. Mechanical evaluation of hip pads to protect against fracture of elderly femurs in falls.

    Science.gov (United States)

    Tadano, Shigeru; Nakatsuchi, Hiroki; Goto, Naoko; Fujisaki, Kazuhiro; Nakatsuchi, Yukio

    2011-01-01

    Hip fracture in the aged easily occurs by falls and may cause these persons to become bedridden. Hip pads are effective in protecting hip fracture as they directly deflect and absorb the impact forces by falls. It is necessary for the material and the structure of hip pads to be designed to realize both high impact absorption and compliance (comfort during wearing). In this report, an impact testing system was developed to test the impact absorbing performance of hip pad with air cushions designed by the research group. The impact absorbing performance was evaluated by the impact load, collision time, and maximum load. To confirm the effectiveness in protecting against hip fracture, an impact force was applied to the greater trochanter of the human femur and the degree of fracture was measured by X-ray examination. As a result, the hip pad with air cushions had a high impact absorbing performance and was sufficiently effective to protect against hip fracture.

  2. Direct application of Padé approximant for solving nonlinear differential equations.

    Science.gov (United States)

    Vazquez-Leal, Hector; Benhammouda, Brahim; Filobello-Nino, Uriel; Sarmiento-Reyes, Arturo; Jimenez-Fernandez, Victor Manuel; Garcia-Gervacio, Jose Luis; Huerta-Chua, Jesus; Morales-Mendoza, Luis Javier; Gonzalez-Lee, Mario

    2014-01-01

    This work presents a direct procedure to apply Padé method to find approximate solutions for nonlinear differential equations. Moreover, we present some cases study showing the strength of the method to generate highly accurate rational approximate solutions compared to other semi-analytical methods. The type of tested nonlinear equations are: a highly nonlinear boundary value problem, a differential-algebraic oscillator problem, and an asymptotic problem. The high accurate handy approximations obtained by the direct application of Padé method shows the high potential if the proposed scheme to approximate a wide variety of problems. What is more, the direct application of the Padé approximant aids to avoid the previous application of an approximative method like Taylor series method, homotopy perturbation method, Adomian Decomposition method, homotopy analysis method, variational iteration method, among others, as tools to obtain a power series solutions to post-treat with the Padé approximant. 34L30.

  3. iPads in the Classrooms of Schools

    DEFF Research Database (Denmark)

    Khalid, Md. Saifuddin; Guttesen, Petur Elias Askham

    2016-01-01

    There is a need for emphasizing on the technological functionalities, pedagogical designs for learning, and barriers to the integration of iPads to inform the resistant teachers, school leaders, parents, and other stakeholders. This paper systematically reviews existing literature on iPads in the......There is a need for emphasizing on the technological functionalities, pedagogical designs for learning, and barriers to the integration of iPads to inform the resistant teachers, school leaders, parents, and other stakeholders. This paper systematically reviews existing literature on i...... categories: 1) functionalities and conveniences in use, 2) iPad motivates, scaffolds learning process, and instills creative problem-solving skills, 3) mobile and multi-contextual, 4) digital content creation and consumption as 21st century skills, 5) barriers to the integration and adoption of iPad, and 6......) scope of future research. There is a dearth of research focusing on the iPad-integrated pedagogical design of subject-specific lessons. This study suggests emphasizing on iPad-integrated pedagogical methods and techniques for subject-specific and app-appropriated learning activity design...

  4. iPad all-in-one for dummies

    CERN Document Server

    Muir, Nancy C

    2015-01-01

    For iPad users who want more information than the basics of the iPad,  iPad All-in-One For Dummies provides the goods! Based on Apple's new iOS software, which includes Siri for iPad, new and improved maps with turn by turn directions, shared photo streams, Facebook integration, Passbook, FaceTime video calls over cellular, new calling features such as instant text reply and callback reminders, improved email with a VIP inbox, iCloud browsing tabs, and much more. The book is organized into the following minibooks: iPad Basics - Covers basic functionality, synching with your computer and getti

  5. iPad 2 The Missing Manual

    CERN Document Server

    Biersdorfer, JD

    2011-01-01

    With iOS 5, Apple added more than 200 new features to the iPad 2, but there's still no printed guide to using all its amazing capabilities. That's where this full-color Missing Manual comes in. You'll learn how to stuff your iPad with media, organize your personal life, wirelessly stream content to and from your tablet, stay connected to friends, and much more. The important stuff you need to know: Build your media library. Fill your iPad with music, movies, TV shows, eBooks, eMagazines, photos, and more.Go wireless. Sync content between your computer and iPad-no wires needed.Get online. Con

  6. Development of radiation shielding materials and NBC pads for infantry combat vehicle and tank

    International Nuclear Information System (INIS)

    Pal, R.S.; Gautam, O.P.; Katiyar, Mohit; Tripathi, D.N.; Singh, R.K.

    2008-01-01

    Tanks have special lining materials inside, providing a certain degree of radiation protection for operation in nuclear scenario's. At present these special lining materials in the form of sheets are imported and are fitted into armoured vehicles. Three types of polymer compositions; PE(M)SE, PEC-ISE and PEC-IISE were formulated based on polymer matrix, specific fillers and anti-ageing additives. Prototype NBC pads based on polymer composition PEC-ISE was finalized for moulding of NBC pads for use in ICVs and composition PE(M)SE was finalized for T-90 tanks. The physico-mechanical properties for NBC pads have been evaluated. Radiography of test samples was conducted to ensure homogeneity of specific fillers in the polymer matrix. Radiation shielding factors against nuclear radiation sources ( 60 Co, I37 Cs and 252 Cf) were evaluated at DL Jodhpur and found to be better than imported Russian Pads designed for ICVs and T-90 Tanks. Drawings for twelve types of NBC pads for ICVs and one hundred eighteen types of pads for T-90 tank were generated with the help of design tool, Auto Desk Inventor-II and metallic moulds for moulding of NBC pads were fabricated. Prototype NBC pads were moulded through compression moulding process. Radiation protection factors of prototype NBC pads, after fitment in ICVs, were also evaluated against neutron and gamma (primary and secondary) radiation sources. Prototype NBC pads for ICVs have shown 20% improvement in overall protection level and NBC pads for T-90 tanks have been developed as per design requirements. Manufacturing facility for NBC shielding pads have been established in association with industries. (author)

  7. An Improved Cambridge Filter Pad Extraction Methodology to Obtain More Accurate Water and “Tar” Values: In Situ Cambridge Filter Pad Extraction Methodology

    Directory of Open Access Journals (Sweden)

    Ghosh David

    2014-07-01

    Full Text Available Previous investigations by others and internal investigations at Philip Morris International (PMI have shown that the standard trapping and extraction procedure used for conventional cigarettes, defined in the International Standard ISO 4387 (Cigarettes -- Determination of total and nicotine-free dry particulate matter using a routine analytical smoking machine, is not suitable for high-water content aerosols. Errors occur because of water losses during the opening of the Cambridge filter pad holder to remove the filter pad as well as during the manual handling of the filter pad, and because the commercially available filter pad holder, which is constructed out of plastic, may adsorb water. This results in inaccurate values for the water content, and erroneous and overestimated values for Nicotine Free Dry Particulate Matter (NFDPM. A modified 44 mm Cambridge filter pad holder and extraction equipment which supports in situ extraction methodology has been developed and tested. The principle of the in situ extraction methodology is to avoid any of the above mentioned water losses by extracting the loaded filter pad while kept in the Cambridge filter pad holder which is hermetically sealed by two caps. This is achieved by flushing the extraction solvent numerous times through the hermetically sealed Cambridge filter pad holder by means of an in situ extractor. The in situ methodology showed a significantly more complete water recovery, resulting in more accurate NFDPM values for high-water content aerosols compared to the standard ISO methodology. The work presented in this publication demonstrates that the in situ extraction methodology applies to a wider range of smoking products and smoking regimens, whereas the standard ISO methodology only applies to a limited range of smoking products and smoking regimens, e.g., conventional cigarettes smoked under ISO smoking regimen. In cases where a comparison of yields between the PMI HTP and

  8. Dynamic characteristics of polymer faced tilting pad journal bearings

    DEFF Research Database (Denmark)

    Simmons, Gregory F.; Cerda Varela, Alejandro Javier; Santos, Ilmar

    2014-01-01

    Dynamic characteristics of polymer faced tilting pad journal bearings are presented. Investigations are conducted using a single pad, load on pad configuration over a range of shaft speeds and loads. Two polyether ether ketone (PEEK) faced pads, one polytetrafluoroethylene (PTFE) faced pad and two...

  9. Analysing the protective potential of padded soccer goalkeeper shorts.

    Science.gov (United States)

    Schmitt, K U; Nusser, M; Derler, S; Boesiger, P

    2010-05-01

    In this study, the potential of currently available padded soccer goalkeeper shorts to prevent hip injuries sustained in side jumps was investigated. Within the scope of this study, a survey among professional and amateur goalkeepers, trainers and the medical staff was performed. In addition, commercially available shorts were impact-tested using an artificial hip model. The results were compared with requirements established for hip protectors for elderly. The results of the survey found that contusions and abrasions were observed most often for all players. Fractures and arthritis were only reported by amateur players, whereas bursitis was more frequently observed by professional players. Amateurs have a significantly higher risk of injury than professional players, and the higher injury risk during training is significantly higher compared with the injury risk during a match. No difference of the injury risk was found between goalkeepers wearing padded shorts and those who did not. Impact tests indicated a wide range of performance of the currently available products. The padded shorts generally reduce impact forces, but mostly perform poorly. Only shorts that were made of visco-elastic foam fulfilled the basic requirements requested for hip protectors for elderly. The quality of most of the currently available goalkeeper shorts needs to be improved to effectively prevent hip injury sustained in side jumps.

  10. iPad application development for dummies

    CERN Document Server

    Goldstein, l

    2012-01-01

    The fun and easy guide to creating iPad apps, updated for iOS 5! iPad app development is hot, with more than 140,000 apps available specifically for the device and that number growing every day. The introduction of iOS 5 and iCloud gives developers even more options to create incredible iPad apps. This fast and friendly guide to iPad app development is fully updated for the most recent upgrades and covers everything you need to know, starting with how to download the SDK and become an Apple developer all the way to finishing up your app and submitting it to the App Store. Zeroes in on essentia

  11. Pericruciate fat pad of the knee: anatomy and pericruciate fat pad inflammation: cadaveric and clinical study emphasizing MR imaging

    International Nuclear Information System (INIS)

    Skaf, Abdalla Youssef; Hernandez Filho, Guinel; Dirim, Berna; Wangwinyuvirat, Mani; Trudell, Debra; Resnick, Donald; Haghigi, Parvitz

    2012-01-01

    The pericruciate fat pad is located in the intercondylar fossa, intimate with the cruciate ligaments. With MR imaging, signal abnormality of the pericruciate fat pad has been observed in patients with posterior knee pain. The purpose of this study was to describe the anatomy of the pericruciate fat pad in cadaveric specimens and to document the clinical spectrum of pericruciate fat pad inflammation. Twelve cadaveric knees underwent MR imaging with T1 and T2 multiplanar images. Cadaveric sections were then prepared for macroscopic evaluation, with additional histologic analysis performed in four cases. MR images in seventeen patients (ten males, seven females; average age, 31.5 years; age range, 19-57 years) involved in intensive sporting activity and with posterior knee pain were reviewed. MR images in cadaveric specimens showed a fat pad that was located above and between the cruciate ligaments, near their attachment sites in the inner portion of the femoral condyles, within the intercondylar fossa. Fatty tissue covered by a thin layer of synovial membrane was confirmed at histology. Seventeen patients with posterior knee pain and without gross cartilage, meniscal, or ligamentous abnormalities all revealed an increased signal in this fat pad in fluid-sensitive fat-suppressed images, mainly in the sagittal and axial planes. In eight cases, enhancement of this fat pad was demonstrated following intravenous gadolinium administration. The pericruciate fat pad is a structure located in the intercondylar fossa, intimate with both the anterior and posterior cruciate ligaments. Inflammatory changes in this fat pad may be found in patients, especially athletes with posterior knee pain. (orig.)

  12. Pericruciate fat pad of the knee: anatomy and pericruciate fat pad inflammation: cadaveric and clinical study emphasizing MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Skaf, Abdalla Youssef [Hospital do Coracao (HCor), Department of Radiology, Sao Paulo, SP (Brazil); Hernandez Filho, Guinel [Santa Casa de Sao Paulo Hospital, Department of Radiology, Sao Paulo, SP (Brazil); Dirim, Berna [Izmir Atatuerk Training and Research Hospital, Department of Radiology, Karsiyaka, izmir (Turkey); Wangwinyuvirat, Mani [Rajavithi Hospital, Department of Radiology, Bangkok (Thailand); Trudell, Debra; Resnick, Donald [University of California, San Diego, Department of Radiology, Veterans Affairs Medical Center, La Jolla, CA (United States); Haghigi, Parvitz [University of California, San Diego, Department of Pathology, Veterans Affairs Medical Center, La Jolla, CA (United States)

    2012-12-15

    The pericruciate fat pad is located in the intercondylar fossa, intimate with the cruciate ligaments. With MR imaging, signal abnormality of the pericruciate fat pad has been observed in patients with posterior knee pain. The purpose of this study was to describe the anatomy of the pericruciate fat pad in cadaveric specimens and to document the clinical spectrum of pericruciate fat pad inflammation. Twelve cadaveric knees underwent MR imaging with T1 and T2 multiplanar images. Cadaveric sections were then prepared for macroscopic evaluation, with additional histologic analysis performed in four cases. MR images in seventeen patients (ten males, seven females; average age, 31.5 years; age range, 19-57 years) involved in intensive sporting activity and with posterior knee pain were reviewed. MR images in cadaveric specimens showed a fat pad that was located above and between the cruciate ligaments, near their attachment sites in the inner portion of the femoral condyles, within the intercondylar fossa. Fatty tissue covered by a thin layer of synovial membrane was confirmed at histology. Seventeen patients with posterior knee pain and without gross cartilage, meniscal, or ligamentous abnormalities all revealed an increased signal in this fat pad in fluid-sensitive fat-suppressed images, mainly in the sagittal and axial planes. In eight cases, enhancement of this fat pad was demonstrated following intravenous gadolinium administration. The pericruciate fat pad is a structure located in the intercondylar fossa, intimate with both the anterior and posterior cruciate ligaments. Inflammatory changes in this fat pad may be found in patients, especially athletes with posterior knee pain. (orig.)

  13. Take control of media on your iPad

    CERN Document Server

    Carlson, Jeff

    2011-01-01

    Join media-savvy author Jeff Carlson as he helps you enjoy media on your iPad like never before. Jeff explains basic and advanced ways of adding media to your iPad, and gives you a thorough grounding in Apple's core media apps-iBooks, iPod, Videos, and Photos. He also helps you integrate your iPad with an Apple TV and looks at various ways of using an iPad as a TV remote. You'll also get plenty of suggestions for third-party apps and products, whether you want to read books not available in the iBookstore, stream music from the Internet to your iPad, convert your own DVD library to iPad-frien

  14. 21 CFR 890.5740 - Powered heating pad.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered heating pad. 890.5740 Section 890.5740...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5740 Powered heating pad. (a) Identification. A powered heating pad is an electrical device intended for medical purposes...

  15. Compression Pad Cavity Heating Augmentation on Orion Heat Shield

    Science.gov (United States)

    Hollis, Brian R.

    2011-01-01

    An experimental study has been conducted to assess the effects of compression pad cavities on the aeroheating environment of the Project Orion Crew Exploration Vehicle heat shield. Testing was conducted in Mach 6 and 10 perfect-gas wind tunnels to obtain heating measurements in and around the compression pads cavities using global phosphor thermography. Data were obtained over a wide range of Reynolds numbers that produced laminar, transitional, and turbulent flow within and downstream of the cavities. The effects of cavity dimensions on boundary-layer transition and heating augmentation levels were studied. Correlations were developed for transition onset and for the average cavity-heating augmentation.

  16. Effects of bedding systems selected by manual muscle testing on sleep and sleep-related respiratory disturbances.

    Science.gov (United States)

    Tsai, Ling-Ling; Liu, Hau-Min

    2008-03-01

    In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.

  17. Teach Yourself VISUALLY iPad

    CERN Document Server

    Watson, Lonzell

    2010-01-01

    An ideal, visual guide for the image-driven iPad. Whether your interests veer towards movies, games, books, or music—the iPad is the computing device for dazzling graphics, crisp and clear audio, and effortless portability. If ever there existed a device that demanded a reading companion for the visual learner, it's the iPad—and this resource is perfectly suited for the visual audience. Veteran VISUAL author Lonzell Watson walks you through all the features unique to the iPad and shows you how to download books, apps, music, and video content, as well as send photos and e-mails. Plus, you'll d

  18. Generation of monoclonal antibodies against peptidylarginine deiminase 2 (PAD2) and development of a PAD2-specific enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Damgaard, Dres; Palarasah, Yaseelan; Skjødt, Karsten

    2014-01-01

    The enzyme peptidylarginine deiminase 2 (PAD2) has been associated with inflammatory diseases, such as rheumatoid arthritis and neurodegenerative diseases including multiple sclerosis. To investigate the association of various diseases with extracellular PAD2, we raised monoclonal antibodies (m......Abs) against rabbit PAD2 and evaluated their cross-reactivity with human PAD2 by indirect enzyme-linked immunosorbent assay (ELISA), western blotting and immunohistological staining of inflamed synovial tissue. Moreover, we established a sandwich ELISA detecting human PAD2, based on two different monoclonal...... diseases....

  19. STS-114: Discovery TCDT Flight Crew Test Media Event at Pad 39-B

    Science.gov (United States)

    2005-01-01

    The STS-114 Space Shuttle Discovery Terminal Countdown Demonstration Test (TCDT) flight crew is shown at Pad 39-B. Eileen Collins, Commander introduces the astronauts. Andrew Thomas, mission specialist talks about his primary responsibility of performing boom inspections, Wendy Lawrence, Mission Specialist 4 (MS4) describes her role as the robotic arm operator supporting Extravehicular Activities (EVA), Stephen Robinson, Mission Specialist 3 (MS3) talks about his role as flight engineer, Charlie Camarda, Mission Specialist 5 (MS5) says that his duties are to perform boom operations, transfer operations from the space shuttle to the International Space Station and spacecraft rendezvous. Soichi Noguchi, Mission Specialist 1 (MS1) from JAXA, introduces himself as Extravehicular Activity 1 (EVA1), and Jim Kelley, Pilot will operate the robotic arm and perform pilot duties. Questions from the news media about the safety of the external tank, going to the International Space Station and returning, EVA training, and thoughts about the Space Shuttle Columbia crew are answered.

  20. Pad A Treatability Study long-range project plan

    International Nuclear Information System (INIS)

    Mousseau, J.D.

    1991-08-01

    The purpose of the Pad A Treatability Study Project is to identify and demonstrate through lab- and pilot-scale testing, technologies for treating plutonium-contaminated salt waste. This document presents proposed objectives and schedules, scope of work and breakdown structure, cost elements, deployment, benefits, and change controls for the project

  1. Water Quality Survey of Splash Pads After A Waterborne Salmonellosis Outbreak--Tennessee, 2014.

    Science.gov (United States)

    Clayton, Joshua L; Manners, Judy; Miller, Susan; Shepherd, Craig; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-06-01

    Waterborne outbreaks of salmonellosis are uncommon. The Tennessee Department of Health investigated a salmonellosis outbreak of 10 cases with the only common risk factor being exposure to a single splash pad. Risks included water splashed in the face at the splash pad and no free residual chlorine in the water system. We surveyed water quality and patron behaviors at splash pads statewide. Of the 29 splash pads participating in the water quality survey, 24 (83%) used a recirculating water system. Of the 24, 5 (21%) water samples were tested by polymerase chain reaction and found to be positive for E. coli, Giardia, norovirus, or Salmonella. Among 95 patrons observed, we identified common high-risk behaviors of sitting on the fountain or spray head and putting mouth to water. Water venue regulations and improved education of patrons are important to aid prevention efforts.

  2. 21 CFR 880.5270 - Neonatal eye pad.

    Science.gov (United States)

    2010-04-01

    ... DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5270 Neonatal eye pad. (a) Identification. A neonatal eye pad is an opaque device used to cover... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neonatal eye pad. 880.5270 Section 880.5270 Food...

  3. Fuel-element vibration and bearing pad to pressure tube fretting

    International Nuclear Information System (INIS)

    Fisher, N.J.; Taylor, C.E.; Pettigrew, M.J.

    1990-08-01

    Fuel channel operation under boiling condition results in increased flow velocities, which may lead to unacceptable fuel-element vibration and bearing pad to pressure tube fretting. The existing endurance test database does not fully cover the range of future channel operating conditions. In particular, after refuelling, some channels for future designs may operate with two-phase flow conditions outside the range of endurance test conditions. Full-scale endurance testing at realistic steam-water conditions involves substantial energy costs. Therefore, fundamental laboratory investigations were conducted to define and endurance test matrix which adequately envelops the future range of operating conditions while minimizing both the number of tests and the energy requirement of individual tests. The main focus of the laboratory investigations was to establish the relationships between: fuel channel flow conditions and fuel-element vibration; and fuel-element vibration and bearing pad to pressure tube fretting. The vibration response of a single fuel element was measured over a wide range of operating conditions covering realistic fuel channel conditions and simulated endurance testing conditions. For higher void fractions, the vibration amplitudes measured in air/water were much higher than in steam/water, while for low void fractions, the amplitudes were similar. The measured amplitudes in steam/water varied very little over the range of temperature and pressure investigated. The effects of temperature, pressure tube oxide thickness, vibration amplitude and bearing pad manufacturer on pressure tube fretting were investigated. The fretting rate is extremely temperature dependent. For vibration amplitudes about three or four times greater than expected in-reactor conditions, peak fretting rates were observed in the 225 to 286 degrees C temperature range. Fretting rates were seven times less at the higher temperatures of 300 and 315 degrees C, and the lower temperatures

  4. On the simplifications for the thermal modeling of tilting-pad journal bearings under thermoelastohydrodynamic regime

    DEFF Research Database (Denmark)

    Cerda Varela, Alejandro Javier; Fillon, Michel; Santos, Ilmar

    2012-01-01

    formulation for inclusion of the heat transfer effects between oil film and pad surface. Such simplified approach becomes necessary when modeling the behavior of tilting-pad journal bearings operating on controllable lubrication regime. Three different simplified heat transfer models are tested, by comparing...... are strongly dependent on the Reynolds number for the oil flow in the bearing. For bearings operating in laminar regime, the decoupling of the oil film energy equation solving procedure, with no heat transfer terms included, with the pad heat conduction problem, where the oil film temperature is applied......The relevance of calculating accurately the oil film temperature build up when modeling tilting-pad journal bearings is well established within the literature on the subject. This work studies the feasibility of using a thermal model for the tilting-pad journal bearing which includes a simplified...

  5. Antimony leaching release from brake pads: Effect of pH, temperature and organic acids.

    Science.gov (United States)

    Hu, Xingyun; He, Mengchang; Li, Sisi

    2015-03-01

    Metals from automotive brake pads pollute water, soils and the ambient air. The environmental effect on water of antimony (Sb) contained in brake pads has been largely untested. The content of Sb in one abandoned brake pad reached up to 1.62×10(4) mg/kg. Effects of initial pH, temperature and four organic acids (acetic acid, oxalic acid, citric acid and humic acid) on Sb release from brake pads were studied using batch reactors. Approximately 30% (97 mg/L) of the total Sb contained in the brake pads was released in alkaline aqueous solution and at higher temperature after 30 days of leaching. The organic acids tested restrained Sb release, especially acetic acid and oxalic acid. The pH-dependent concentration change of Sb in aqueous solution was best fitted by a logarithmic function. In addition, Sb contained in topsoil from land where brake pads were discarded (average 9×10(3) mg/kg) was 3000 times that in uncontaminated soils (2.7±1 mg/kg) in the same areas. Because potentially high amounts of Sb may be released from brake pads, it is important that producers and environmental authorities take precautions. Copyright © 2015. Published by Elsevier B.V.

  6. Disinfecting the iPad: evaluating effective methods.

    Science.gov (United States)

    Howell, V; Thoppil, A; Mariyaselvam, M; Jones, R; Young, H; Sharma, S; Blunt, M; Young, P

    2014-06-01

    Tablet computers are increasingly used in healthcare, but they may carry nosocomial pathogens. There are few data available on how to clean an iPad effectively for use in the clinical setting. We aimed to identify the most effective method of decontaminating the Apple iPad, without causing damage, and establish the duration of any residual effect. Following contamination with a microbial broth (meticillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococcus (VRE) and Clostridium difficile), we examined efficacy of iPad disinfection in the laboratory using six different disinfectant wipes: Sani-Cloth CHG 2% (chlorhexidine 2%/alcohol 70%), Clorox, Tristel, Trigene, soap and water, and plain cloth. Following cleaning, iPads were recontaminated to examine residual activity. After 480 Sani-Cloth CHG 2% disinfecting episodes, functional and visual analysis of iPads was performed by blinded subjects. With the exception of Clostridium difficile, Sani-Cloth CHG 2% and Clorox wipes were most effective against MRSA and VRE, and they were significantly better than the Apple-recommended plain cloth (P ≤ 0.001). A substantial residual antimicrobial effect was seen for >6h after wiping the iPad with Sani-Cloth CHG 2% despite repeated recontamination and without further disinfection. The functionality or visual appearance of the iPad was not damaged by repeated use of Sani-Cloth CHG 2% wipes. Sani-Cloth CHG 2% wipes effectively disinfect the iPad against MRSA and VRE, with a residual antibacterial effect and without causing damage. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Pad B Liquid Hydrogen Storage Tank

    Science.gov (United States)

    Hall, Felicia

    2007-01-01

    Kennedy Space Center is home to two liquid hydrogen storage tanks, one at each launch pad of Launch Complex 39. The liquid hydrogen storage tank at Launch Pad B has a significantly higher boil off rate that the liquid hydrogen storage tank at Launch Pad A. This research looks at various calculations concerning the at Launch Pad B in an attempt to develop a solution to the excess boil off rate. We will look at Perlite levels inside the tank, Boil off rates, conductive heat transfer, and radiant heat transfer through the tank. As a conclusion to the research, we will model the effects of placing an external insulation to the tank in order to reduce the boil off rate and increase the economic efficiency of the liquid hydrogen storage tanks.

  8. iPad The Missing Manual

    CERN Document Server

    Biersdorfer, J

    2010-01-01

    The iPad 2 is faster, lighter, and more versatile than its predecessor, but there's still no printed guide to using its amazing features. That's where this full-color Missing Manual comes in. Learn how to stream HD video, make video calls, manage your email, surf the Web, listen to music, play games, and maybe even do a little iWork. This is the book that should have been in the box. Build your media library. Fill your iPad with music, movies, TV shows, eBooks, photos, and more.Share with others. Stream music, HD movies, TV shows, and more, to and from your iPad.Create your own media. Use the

  9. Video game induced knuckle pad.

    Science.gov (United States)

    Rushing, Mary E; Sheehan, Daniel J; Davis, Loretta S

    2006-01-01

    Controversy and concern surround the video game playing fascination of children. Scientific reports have explored the negative effects of video games on youth, with a growing number recognizing the actual physical implications of this activity. We offer another reason to discourage children's focus on video games: knuckle pads. A 13-year-old black boy presented with an asymptomatic, slightly hyperpigmented plaque over his right second distal interphalangeal joint. A punch biopsy specimen confirmed knuckle pad as the diagnosis, and a traumatic etiology from video game playing was suspected. Knuckle pads can be painful, cosmetically unappealing, and refractory to treatment. They can now be recognized as yet another potential adverse consequence of chronic video game playing.

  10. Ectopic expression of AtPAD4 broadens resistance of soybean to soybean cyst and root-knot nematodes.

    Science.gov (United States)

    Youssef, Reham M; MacDonald, Margaret H; Brewer, Eric P; Bauchan, Gary R; Kim, Kyung-Hwan; Matthews, Benjamin F

    2013-04-25

    The gene encoding PAD4 (PHYTOALEXIN-DEFICIENT4) is required in Arabidopsis for expression of several genes involved in the defense response to Pseudomonas syringae pv. maculicola. AtPAD4 (Arabidopsis thaliana PAD4) encodes a lipase-like protein that plays a regulatory role mediating salicylic acid signaling. We expressed the gene encoding AtPAD4 in soybean roots of composite plants to test the ability of AtPAD4 to deter plant parasitic nematode development. The transformed roots were challenged with two different plant parasitic nematode genera represented by soybean cyst nematode (SCN; Heterodera glycines) and root-knot nematode (RKN; Meloidogyne incognita). Expression of AtPAD4 in soybean roots decreased the number of mature SCN females 35 days after inoculation by 68 percent. Similarly, soybean roots expressing AtPAD4 exhibited 77 percent fewer galls when challenged with RKN. Our experiments show that AtPAD4 can be used in an economically important crop, soybean, to provide a measure of resistance to two different genera of nematodes.

  11. iPad-based patient briefing for radiological examinations-a clinical trial.

    Science.gov (United States)

    Schlechtweg, Philipp M; Hammon, Matthias; Giese, David; Heberlein, Christian; Uder, Michael; Schwab, Siegfried A

    2014-08-01

    To analyze if an iPad-based patient briefing can serve as a digital alternative to conventional documentations prior to radiological examinations. One hundred one patients referred for routine MRI were randomized into two groups, who underwent iPad-based and classic written briefing in opposite order. For each briefing completion time, completeness and correctness were noted. Patient's knowledge about the content of either briefing modality was subsequently tested. The influence of patient-related factors on the performance of the electronic briefing (EB) was analyzed. Finally, the patient's subjective impression of the EB was assessed. The mean durations were 4.4 ± 2.2 min for EB and 1.7 ± 1.3 min for the classic briefing (p iPad briefings were returned entirely filled out, whereas 11 % of the classic forms were returned with missing data. No significant differences in memorization of the briefing's information were objectified. There was a positive correlation between the duration of EB and age (r = 0.53; p iPads transfers the information for the patients equally well compared to the classic written approach. Although iPad briefing took patients longer to perform, the majority would prefer it to written consent briefings in the future. Nevertheless, measures have to be undertaken to improve the overall acceptance and performance.

  12. Effects of a Combined Exercise Program Using an iPad for Older Adults.

    Science.gov (United States)

    Lee, Juhee; Jung, Dukyoo; Byun, Jinyee; Lee, Minkyung

    2016-04-01

    The purpose of this study was to examine the function, health status, and efficacy effects of a combined exercise program using an iPad among older women in Korea, a tech-savvy country. The study employed a pretest and posttest experimental design with a control group. The experimental group of subjects comprised 16 female older adults and the control group comprised 10 who were aged 65 years or older. The experimental group participated in a supervised group-based exercise program and an individualized home-based exercise program that involved the use of an iPad. The combined group and home-based exercise program consisted of group exercise, which took place in a senior center for 30 minutes weekly, and a home-based iPad exercise program, which the subjects followed at least 3 times a week. The collected data were analyzed using the Statistical Analysis System (SAS ver. 9.3 TS Level 1M0) program, which utilized a chi-square test, a Fisher exact test, a t-test, and a repeated-measures ANOVA. The results showed that cognitive status changed significantly over time, and there was an interaction between group and time. Further, self-efficacy for exercise and outcome expectations for exercise changed significantly over time. Exercise programs using iPad interventions may be useful for the management of cognitive functioning and the integration of functional physical abilities in older adults.

  13. On the Design of Tilting-Pad Thrust Bearings

    OpenAIRE

    Heinrichson, Niels; Santos, Ilmar

    2007-01-01

    Pockets are often machined in the surfaces of tilting-pad thrust bearings to allow for hydrostatic jacking in the start-up phase. Pockets and other recesses in the surfaces of bearing pads influence the pressure distribution and thereby the position of the pivot resulting in the most advantageous pad convergence ratio. In this thesis, a theoretical approach is applied in the attempt to quantify the influence of recesses in the pad surfaces. The recesses may be relatively deep and enclosed as ...

  14. Stopping the wave of PAD.

    Science.gov (United States)

    Brazziel, Tracy; Cox, Lindsie; Drury, Christa; Guerra, Maria

    2011-11-01

    Peripheral arterial disease (PAD) has a substantial impact on individual quality of life and is a significant financial burden to society. It is underdiagnosed, and therefore, undertreated. Early detection and treatment is essential to prevent increases in morbidity and mortality. The purpose of this article is to review evidence-based articles regarding prevalence, screening, diagnosis, and management of PAD. Copyright © 2011 Lippincott Williams & Wilkins.

  15. TagPad

    DEFF Research Database (Denmark)

    Bornoe, Nis; Barkhuus, Louise

    2013-01-01

    The area of cyberinfrastructures has looked extensively at research within the natural sciences, however, the social sciences have been largely overlooked in terms of novel data collection and analysis systems. We developed a probe tool, TagPad, to look at the process for social science data...

  16. Microstructural evaluation of interfacial intermetallic compounds in Cu wire bonding with Al and Au pads

    International Nuclear Information System (INIS)

    Kim, Hyung Giun; Kim, Sang Min; Lee, Jae Young; Choi, Mi Ri; Choe, Si Hyun; Kim, Ki Hong; Ryu, Jae Sung; Kim, Sangshik; Han, Seung Zeon; Kim, Won Yong; Lim, Sung Hwan

    2014-01-01

    A comparative study on the difference in interfacial behavior of thermally aged Cu wire bonding with Al and Au pads was conducted using transmission electron microscopy. During high-temperature lifetime testing of Cu wire bonding with Al and Au pads at 175 °C for up to 2000 h, different growth rates and growth characteristics were investigated in the Cu–Al intermetallic compounds (IMCs), including CuAl 2 , CuAl and Cu 9 Al 4 , and in the Cu–Au IMCs, including (Au,Cu), Cu 3 Au and (Cu,Au). Because of the lower growth rates and greater ductility of Cu–Au IMCs compared to those of Cu–Al IMCs, the Cu wire bonding with the Au pad showed relatively better thermal aging properties of bond pull strength and ball shear strength than those with the Al pad counterpart. In this study, the coherent interfaces were found to retard the growth of IMCs, and a variety of orientation relationships between wire, pad and interfacial IMCs were identified

  17. High-pitch metal-on-glass technology for pad pitch adaptation between detectors and readout electronics

    CERN Document Server

    Ullán, Miguel; Campabadal, Francesca; Fleta, Celeste; Garcia, Carmen; Gonzalez, Francisco; Bernabeu, Jose

    2004-01-01

    Modern high-energy physics and astrophysics strip detectors have increased channel density to levels at which their connection with readout electronics has become very complex due to high pad pitch. Also, direct wire bonding is prevented by the fact that typically detector's pad pitch and electronics' pad pitch do not match. A high- pitch metal-on-glass technology is presented, that allows pad pitch adaptation between detectors and readout electronics. It consists of high-density metal lines on top of an insulating glass substrate. A photoresist layer is deposited covering the metal tracks for passivation and protection The technology is tested for conductivity, bondability, bonding pull force, peel off, and radiation hardness, and it is an established technology in the clean room of the CNM Institute in Barcelona. This technology has been chosen by the ATLAS Collaboration for the pad pitch adapters (PPA) of the SCT Endcap Modules, by a Compton camera project, and by other HEP groups for interconnection betwe...

  18. Taking Your iPad 2 to the Max

    CERN Document Server

    Sadun, Erica; Sande, Steve

    2011-01-01

    iPad 2: It looks different. It acts different. It connects to the world, yet it is as personal as a well-worn book. And now it has two cameras!. Taking Your iPad 2 to the Max is written so that anyone can quickly get up to speed on Apple's latest hit. As bloggers at The Unofficial Apple Weblog (TUAW.com), the authors have the happy privilege of working with Apple products every day, and they'll guide you through all of the perks of being an iPad 2 owner. This book takes you from selecting and buying an iPad, to connecting it to the Internet, to using the incredible power of the iPad and all it

  19. ACNE VULGARIS. EVALUATION OF A MEDICATED CLEANSING PAD.

    Science.gov (United States)

    ROTH, H L

    1964-03-01

    Using the technique of simultaneous, symmetrical paired comparisons, a medicated cleansing pad that can be easily used at work or at school as an adjunctive in the treatment of acne vulgaris was evaluated.The experimental pads were significantly beneficial in reducing skin oiliness and in clinical improvement of the acne. Response to standard acne therapy was faster when the pads were used adjunctively, although the significant results seen initially tended to even out as therapy continued. Use of the medicated pads produced no untoward side effects and were well accepted by patients.

  20. ACNE VULGARIS—Evaluation of a Medicated Cleansing Pad

    Science.gov (United States)

    Roth, Harry L.

    1964-01-01

    Using the technique of simultaneous, symmetrical paired comparisons, a medicated cleansing pad that can be easily used at work or at school as an adjunctive in the treatment of acne vulgaris was evaluated. The experimental pads were significantly beneficial in reducing skin oiliness and in clinical improvement of the acne. Response to standard acne therapy was faster when the pads were used adjunctively, although the significant results seen initially tended to even out as therapy continued. Use of the medicated pads produced no untoward side effects and were well accepted by patients. PMID:14131397

  1. Ouders positief over iPad in het onderwijs

    NARCIS (Netherlands)

    Klaas Jan Huizing; Kirsten Andringa; Jildou Braaksma

    2014-01-01

    In 2012 is de iPad geïmplementeerd in het voorgezet middelbare onderwijs van Piter Jelles de Dyk in Leeuwarden. Sowijs volgde de implementatie van de iPad. In dit whitepaper wordt beschreven hoe ouders van leerlingen het iPad-gebruik op school ervaren. Welke voor- of nadelen zien zij in het

  2. Comparison of postural sway depending on balance pad type.

    Science.gov (United States)

    Lee, DongGeon; Kim, HaNa; An, HyunJi; Jang, JiEun; Hong, SoungKyun; Jung, SunHye; Lee, Kyeongbong; Choi, Myong-Ryol; Lee, Kyung-Hee; Lee, GyuChang

    2018-02-01

    [Purpose] The purpose of the present study was to compare the postural sway of healthy adults standing on different types of balance pads. [Subjects and Methods] Nine healthy adults participated in this study. Postural body sway was measured while participants were standing on four different types of balance pads: Balance-pad Elite (BE), Aero-Step XL (AS), Dynair Ballkissen Senso (DBS), and Dynair Ballkissen XXL Meditation and Yoga (DBMY). A Wii Balance Board interfaced with Balancia software was used to measure postural body sway. [Results] In the sway velocity, sway path length, and sway area, no significant differences were found between baseline conditions (participants were standing on the floor with no balance pad) and the use of the BE or AS. However, significant increases in all parameters were found comparing baseline conditions to the use of either Dynair balance pad. Furthermore, the use of either Dynair balance pad significantly increased postural sway compared to both the BE and the AS. [Conclusion] These findings suggest that the DBS and DBMY balance pads may serve as superior tools for providing unstable condition for balance training than the BE and the AS balance pads.

  3. iPad For Seniors For Dummies

    CERN Document Server

    Muir, Nancy C

    2010-01-01

    The full-color guide to the exciting new iPad, written specifically with the needs of seniors in mind!. The iPad is the perfect device for the senior market, combining the Web, e-mail, photos, video, and book reading into an intuitive, portable device. Written by veteran Dummies author Nancy Muir, this fun and friendly guide shows you how to use the many features and capabilities of the iPad to make life easier! You'll learn how to use the multitouch screen to zoom in and out on Web pages and choose a font and size that makes reading comfortable so that you can get directions, plan vacations,

  4. Apollo 6 Transported to Launch Pad at KSC

    Science.gov (United States)

    1968-01-01

    Apollo 6, the second and last of the unmarned Saturn V test flights, is slowly transported past the Vehicle Assembly Building on the way to launch pad 39-A. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  5. Analysis of the March 30, 2011 Hail Event at Shuttle Launch Pad 39A

    Science.gov (United States)

    Lane, John E.; Doesken, Nolan J.; Kasparis, Takis C.; Sharp, David W.

    2012-01-01

    The Kennedy Space Center (KSC) Hail Monitor System, a joint effort of the NASA KSC Physics Lab and the KSC Engineering Services Contract (ESC) Applied Technology Lab, was first deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain, Hail, and Snow Network (CoCoRaHS) in conjunction with Colorado State University have been instrumental in validation testing using duplicate hail monitor systems at sites in the hail prone high plains of Colorado. The KSC Hail Monitor System (HMS), consisting of three stations positioned approximately 500 ft from the launch pad and forming an approximate equilateral triangle, as shown in Figure 1, was first deployed to Pad 39B for support of STS-115. Two months later, the HMS was deployed to Pad 39A for support of STS-116. During support of STS-117 in late February 2007, an unusually intense (for Florida standards) hail event occurred in the immediate vicinity of the exposed space shuttle and launch pad. Hail data of this event was collected by the HMS and analyzed. Support of STS-118 revealed another important application of the hail monitor system. Ground Instrumentation personnel check the hail monitors daily when a vehicle is on the launch pad, with special attention after any storm suspected of containing hail. If no hail is recorded by the HMS, the vehicle and pad inspection team has no need to conduct a thorough inspection of the vehicle immediately following a storm. On the afternoon of July 13, 2007, hail on the ground was reported by observers at the Vertical Assembly Building (VAB) and Launch Control Center (LCC), about three miles west of Pad 39A, as well as at several other locations at KSC. The HMS showed no impact detections, indicating that the shuttle had not been damaged by any of the numerous hail events which occurred on that day.

  6. Evaluation of the Thermal Effects in Tilting Pad Bearing

    Directory of Open Access Journals (Sweden)

    G. B. Daniel

    2013-01-01

    Full Text Available The analysis of thermal effects is of expressive importance in the context of rotordynamics to evaluate the behavior of hydrodynamic bearings because these effects can influence their dynamic characteristics under specific operational conditions. For this reason, a thermohydrodynamic model is developed in this work, in which the pressure distribution in the oil film and the temperature distribution are calculated together. From the pressure distribution, the velocity distribution field is determined, as well as the viscous dissipation, and consequently, the temperature distribution. The finite volume method is applied to solve the Reynolds equation and the energy equation in the thermohydrodynamic model (THD. The results show that the temperature is higher as the rotational speed increases due to the shear rate of the oil film. The maximum temperature in the bearing occurs in the overloaded pad, near the outlet boundary. The experimental tests were performed in a tilting pad journal bearing operating in a steam turbine to validate the model. The comparison between the experimental and numerical results provides a good correlation. The thermohydrodynamic lubrication developed in this assignment is promising to consistently evaluate the behavior of the tilting pad journal bearing operating in relatively high rotational speeds.

  7. Is the iPad suitable for image display at American Board of Radiology examinations?

    Science.gov (United States)

    Toomey, Rachel J; Rainford, Louise A; Leong, David L; Butler, Marie-Louise; Evanoff, Michael G; Kavanagh, Eoin C; Ryan, John T

    2014-11-01

    The study aimed to determine the acceptability of the iPad 3 as a display option for American Board of Radiology (ABR) examinations. A set of 20 cases for each of nine specialties examined by the ABR was prepared. Each comprised between one and seven images and case information and had been used in previous ABR Initial Certification examinations. Examining radiologists (n = 119) at the ABR oral Initial Certification examinations reviewed sets from one or more specialties on both a 2 MP LED monitor and on the iPad 3 and rated the visibility of the salient image features for each case. The Wilcoxon signed rank test was performed to compare ratings. In addition, a thematic analysis of participants' opinions was undertaken. When all specialties were pooled, the iPad 3 ratings were significantly higher than the monitor ratings (p = 0.0217). The breast, gastrointestinal, genitourinary, and nuclear medicine specialties also returned significantly higher ratings for the visibility of relevant image features for the iPad 3. Monitor ratings were significantly higher for the vascular and interventional specialty, although no images were rated unacceptably poor on the iPad in this specialty. The relevant image features were rated more visible on the iPad 3 than on the monitors overall. The iPad 3 was well accepted by a large majority of examiners and can be considered adequate for image display for examination in most or all specialties.

  8. iPads in Higher Education--Hype and Hope

    Science.gov (United States)

    Nguyen, Lemai; Barton, Siew Mee; Nguyen, Linh Thuy

    2015-01-01

    This paper systematically reviews current research on using iPads in the higher education sector. Since the release of iPads by Apple in 2010, this new technology has been quickly adopted everywhere, especially by the younger generation and professionals. We were motivated to find out how iPads have been adopted for use in the higher education…

  9. Er iPad digital udeskole?

    DEFF Research Database (Denmark)

    Schilhab, Theresa

    2014-01-01

    Hvor ’konkret’ skal en oplevelse være, for at intuitionen om, at det selvoplevede styrker læringen, holder? Er brug af tablets (e.g. iPads) et ligebyrdigt alternativ til den konkrete oplevelse?......Hvor ’konkret’ skal en oplevelse være, for at intuitionen om, at det selvoplevede styrker læringen, holder? Er brug af tablets (e.g. iPads) et ligebyrdigt alternativ til den konkrete oplevelse?...

  10. Development of a compact 25-channel preamplifier module for Si-pad detectors of the BARC-CPDA

    International Nuclear Information System (INIS)

    Inkar, A.; John, Bency; Vind, R.P.; Kinage, L.; Jangale, R.V.; Biswas, D.C.; Nayak, B.K.

    2011-01-01

    The BARC Charged Particle Detector Array modules use indigenously developed Si pad detectors as their first element. Total number of charge sensitive pre-amplifiers required for the Si-pad detectors is 250. One of the main ideas here is a layout of five pre-amplifiers connected with one Si-pad detector (called a bank of preamplifiers). In the present work, a 25-channel pre-amplifier module that can cater to 5 independent Si-pad detectors, or a five-bank module, has been developed. This module uses pre-amp hybrid chips A1422H from CAEN S.p.A. and is housed in a double width NIM standard box. The module has been tested for performance using proton and ''7Li beams from FOTIA facility, Trombay

  11. Development of a high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors.

    Science.gov (United States)

    Suresh, R; Bhalla, S; Hao, J; Singh, C

    2015-01-01

    High importance is given to plantar pressure monitoring in the field of biomedical engineering for the diagnosis of posture related ailments associated with diseases such as diabetes and gonarthrosis. This paper presents the proof-of-concept development of a new high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors. In the proposed configuration, the FBG sensors are embedded within layers of carbon composite material (CCM) in turn conforming to an arc shape. A total of four such arc shaped sensors are instrumented in the pad at the locations of the forefoot and the hind foot. As a test of the pad, static plantar pressure is monitored on normal subjects under various posture conditions. The pad is evaluated both as a standalone platform as well as a pad inserted inside a standard shoe. An average pressure sensitivity of 1.2 pm/kPa and a resolution of approximately 0.8 kPa is obtained in this special configuration. The pad is found to be suitable in both configurations- stand-alone pad as well as an insert inside a standard shoe. The proposed set up offers a cost-effective high resolution and accurate plantar pressure measurement system suitable for clinical deployment. The novelty of the developed pressure pad lies in its ability to be used both as platform type as well as inserted in-sole type sensor system.

  12. On the Design of Tilting-Pad Thrust Bearings

    DEFF Research Database (Denmark)

    Heinrichson, Niels

    2007-01-01

    Pockets are often machined in the surfaces of tilting-pad thrust bearings to allow for hydrostatic jacking in the start-up phase. Pockets and other recesses in the surfaces of bearing pads influence the pressure distribution and thereby the position of the pivot resulting in the most advantageous...... based on the Reynolds equation are used. They include the effects of variations of viscosity with temperature and the deformation of the bearing pads due to pressure and thermal gradients. The models are validated using measurements. Tilting-pad bearings of standard design are studied and the influences...... of the friction loss. Both this bearing and the bearing design with enclosed recesses in the high-pressure regions of the pads suffer from a higher sensitivity to the position of the pivot. The design of such bearing is therefore no trivial task....

  13. Diagnostic procedure on brake pad assembly based on Young's modulus estimation

    International Nuclear Information System (INIS)

    Chiariotti, P; Santolini, C; Tomasini, E P; Martarelli, M

    2013-01-01

    Quality control of brake pads is an important issue, since the pad is a key component of the braking system. Typical damage of a brake pad assembly is the pad–backing plate detachment that affects and modifies the mechanical properties of the whole system. The most sensitive parameter to the damage is the effective Young's modulus, since the damage induces a decrease of the pad assembly stiffness and therefore of its effective Young's modulus: indeed its variation could be used for diagnostic purposes. The effective Young's modulus can be estimated from the first bending resonance frequency identified from the frequency response function measured on the pad assembly. Two kinds of excitation methods, i.e. conventional impulse excitation and magnetic actuation, will be presented and two different measurement sensors, e.g. laser Doppler vibrometer and microphone, analyzed. The robustness of the effective Young's modulus as a diagnostic feature will be demonstrated in comparison to the first bending resonance frequency, which is more sensitive to geometrical dimensions. Variability in the sample dimension, in fact, will induce a variation of the resonance frequency which could be mistaken for damage. The diagnostic approach has been applied to a set of undamaged and damaged pad assemblies showing good performance in terms of damage identification. The environmental temperature can be an important interfering input for the diagnostic procedure, since it influences the effective Young's modulus of the assembly. For that reason, a test at different temperatures in the range between 15 °C and 30 °C has been performed, evidencing that damage identification technique is efficient at any temperature. The robustness of the Young's modulus as a diagnostic feature with respect to damping is also presented. (paper)

  14. Allergic contact dermatitis to acrylates in disposable blue diathermy pads.

    Science.gov (United States)

    Sidhu, S. K.; Shaw, S.

    1999-01-01

    We report 2 cases of elicitation of allergic contact dermatitis to acrylates from disposable blue diathermy pads used on patients who underwent routine surgery. Their reactions were severe, and took approximately 5 weeks to resolve. Both patients gave a prior history of finger tip dermatitis following the use of artificial sculptured acrylic nails, which is a common, but poorly reported, cause of acrylate allergy. Patch testing subsequently confirmed allergies to multiple acrylates present in both the conducting gel of disposable blue diathermy pads, and artificial sculptured acrylic nails. We advocate careful history taking prior to surgery to avoid unnecessary exposure to acrylates in patients already sensitized. Images Figure 1 Figure 2 PMID:10364952

  15. Binocular iPad treatment for amblyopia in preschool children.

    Science.gov (United States)

    Birch, Eileen E; Li, Simone L; Jost, Reed M; Morale, Sarah E; De La Cruz, Angie; Stager, David; Dao, Lori; Stager, David R

    2015-02-01

    Recent experimental evidence supports a role for binocular visual experience in the treatment of amblyopia. The purpose of this study was to determine whether repeated binocular visual experience with dichoptic iPad games could effectively treat amblyopia in preschool children. A total of 50 consecutive amblyopic preschool children 3-6.9 years of age were assigned to play sham iPad games (first 5 children) or binocular iPad games (n = 45) for at least 4 hours per week for 4 weeks. Thirty (67%) children in the binocular iPad group and 4 (80%) in the sham iPad group were also treated with patching at a different time of day. Visual acuity and stereoacuity were assessed at baseline, at 4 weeks, and at 3 months after the cessation of game play. The sham iPad group had no significant improvement in visual acuity (t4 = 0.34, P = 0.75). In the binocular iPad group, mean visual acuity (plus or minus standard error) improved from 0.43 ± 0.03 at baseline to 0.34 ± 0.03 logMAR at 4 weeks (n = 45; paired t44 = 4.93; P iPad games for ≥8 hours (≥50% compliance) had significantly more visual acuity improvement than children who played 0-4 hours (t43 = 4.21, P = 0.0001). Repeated binocular experience, provided by dichoptic iPad game play, was more effective than sham iPad game play as a treatment for amblyopia in preschool children. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  16. Role of the calcaneal heel pad and polymeric shock absorbers in attenuation of heel strike impact.

    Science.gov (United States)

    Noe, D A; Voto, S J; Hoffmann, M S; Askew, M J; Gradisar, I A

    1993-01-01

    The capacity of the calcaneal heel pad, with and without augmentation by a polymeric shock absorbing material (Sorbothane 0050), to attenuate heel strike impulses has been studied using five fresh human cadaveric lower leg specimens. The specimens, instrumented with an accelerometer, were suspended and impacted with a hammer; a steel rod was similarly suspended and impacted. The calcaneal heel pad attenuated the peak accelerations by 80%. Attenuations of up to 93% were achieved by the shock absorbing material when tested against the steel rod; however, when tested in series with the calcaneal heel pad, the reduction in peak acceleration due to the shock absorbing material dropped to 18%. Any evaluation of the effectiveness of shock absorbing shoe materials must take into account their mechanical interaction with the body.

  17. Using iPads to Your Advantage

    Science.gov (United States)

    Zakrzewski, Jennifer L.

    2016-01-01

    In this article, middle school mathematics teacher Jennifer Zakrzewski describes how she successfully incorporated iPads and Apple TV (for projection of iPad screens) into her classroom while having her students solve a problem about mangoes. As Zakrzewski began a unit on multiplying and dividing fractions, she chose to start with the Mangoes…

  18. Resident iPad use: has it really changed the game?

    Science.gov (United States)

    Berkowitz, Seth J; Kung, Justin W; Eisenberg, Ronald L; Donohoe, Kevin; Tsai, Leo L; Slanetz, Priscilla J

    2014-02-01

    The purpose of this study was to assess residents' usage patterns and opinions of the iPad as a tool for radiology education and clinical practice at an academic medical center. All 38 radiology residents in our radiology program (postgraduate years 2 to 5) were provided with iPad 2 tablets and subscriptions to e-Anatomy and STATdx. After 6 months of device use, residents were surveyed to assess their opinions regarding the technology as a tool for education and clinical practice. A total of 36 residents (95%) completed the survey. Eighty-six percent reported daily iPad use. Radiology-specific applications, particularly e-Anatomy, were used weekly or daily by 88% of respondents. Most preferred to read journal articles on the iPad (70%), but the number of respondents preferring to read textbooks on the iPad (48.5%) compared with the traditional bound form (48.5%) was evenly divided. Residents were also divided on the clinical utility of the iPad. Most had not used the iPad to view radiologic examinations (75%). Fewer than half (47%) used their iPads during readout. Finally, only 12% had used the iPad to edit dictated reports. The iPad has generated excitement within the radiology community, particularly among resident educators, who are increasingly recognizing the unique needs of "millennial learners." This study showed that the majority of residents at the authors' institution have incorporated the iPad as an educational tool and use it as a learning aid. Incorporation of the iPad into clinical workflow has been less pronounced. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Improved CHESS imaging with the use of rice pads: Investigation in the neck, shoulder, and elbow.

    Science.gov (United States)

    Moriya, Susumu; Miki, Yukio; Yokobayashi, Tsuneo; Yamamoto, Akira; Kanagaki, Mitsunori; Komori, Yoshiaki; Fujimoto, Koji; Ishikawa, Mitsunori

    2010-06-01

    To investigate the feasibility of rice pads for improving nonuniform fat suppression in magnetic resonance imaging (MRI) of the neck, shoulder, and elbow using the chemical shift selective (CHESS) technique. CHESS imaging of the neck, shoulder, and elbow was performed on 10 healthy volunteers with and without the use of rice pads. Images were visually assessed by one radiologist and one radiologic technologist using a four-point scale. Results were compared using Wilcoxon's signed rank sum test. Images with and without rice pads were rated 3.9 and 1.5 for the neck (P = 0.002), 3.85 and 2.5 for the shoulder (P = 0.002), and 3.4 and 2.45 for the elbow (P = 0.004). Fat-suppressed images obtained using the CHESS technique were significantly improved by rice pads for the neck, shoulder, and elbow, indicating that image deterioration with CHESS caused by magnetic field nonuniformity can be improved by rice pads in all body areas.

  20. Learning Chinese Idioms through iPads

    Science.gov (United States)

    Yang, Chunsheng; Xie, Ying

    2013-01-01

    This paper reports on an action research study using iPads during the teaching of Chinese idioms to heritage learners. A class of 12 second-year Chinese learners were engaged in a self-generated learning process focused on learning abstract and concrete idioms using iPads. Students' short-term and long-term learning was measured; feedback from a…

  1. Development of Asbestos - Free Brake Pad Using Bagasse

    Directory of Open Access Journals (Sweden)

    V. S. Aigbodion

    2010-03-01

    Full Text Available Development of asbestos-free brake pad using bagasse was investigated with a view to replace the use of asbestos whose dust is carcinogenic. The bagasse were sieve into sieve grades of 100, 150, 250, 350 and 710µm. the sieve bagasse was used in production of brake pad in ratio of 70%bagasse-30%resin using compression moulding. The properties examined are microstructure analysis, hardness, compressive strength, density, flame resistance, water and oil absorption. The microstructure reveals uniform distribution of resin in the bagasse. The results obtained showed that the finer the sieve size the better the properties. The results obtained in this work were compared with that of commercial brake pad (asbestos based and optimum formulation laboratory brake pad Palm Kernel Shell based (PKS, the results are in close agreement. Hence bagasse can be used in production of asbestos-free brake pad.

  2. Corrosion investigation of material combinations in a mobile phone dome-key pad system

    DEFF Research Database (Denmark)

    Ambat, Rajan; Møller, Per

    2007-01-01

    to multiple corrosion problems. In this paper, the corrosion susceptibility of dome (Ag/AISI 202 steel) and key pad system (Au/Ni/Cu) is investigated with an aim to understand the corrosion performance of such multi-material combinations in chloride containing environment. Investigation includes...... microstructural studies, polarization measurements using microelectrochemical technique, salt spray testing, and corrosion morphology analysis. The immersion Au layer on pads showed pores, and rolled bonded silver layer on dome had cracks and kinks. The difference in electrochemical behaviour of the metallic...... layers together with imperfections in the top layer results in severe pitting due to galvanic coupling. However, corrosion performance of the pads was much worse than domes. The results are applicable to a broad spectrum of PCB parts where similar material combinations are employed, especially Au/Ni/Cu....

  3. Medical student use of the iPad in the clerkship curriculum.

    Science.gov (United States)

    Youm, Julie; Wiechmann, Warren

    2015-12-01

    There is little precedence for the implementation of a medical school iPad programme in a clinical setting. This study analysed students' use of iPad apps and perceptions of the iPad as a clinical tool in a clinical third-year medical school curriculum. All third-year medical students (n = 103) were provided iPads for use during their regular clinical rotations. Students received an orientation that included an introduction to the recommended apps selected for the study. A pre-survey (82.5% response rate) and post-survey (47.6% response rate) were administered to determine students' use of specific iPad programs, activities performed on the iPad and their perceptions. Students reported technology proficiency with the iPad and positive perceptions about its use in a clinical setting. They reported using a few key apps out of the many specialty-specific apps recommended to them. Students found efficiency through their ability to study during downtime, and through quick access to information and mobile access to electronic medical records, amongst the greatest benefits of having an iPad during their rotations. Improving Wi-Fi infrastructure and offering timely iPad orientations could decrease challenges to students' clinical iPad apps use. This study analysed students' use of iPad apps and perceptions of the iPad as a clinical too. © 2015 John Wiley & Sons Ltd.

  4. Closure Report for Corrective Action Unit 224: Decon Pad and Septic Systems, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    NSTec Environmental Restoration

    2007-01-01

    Corrective Action Unit (CAU) 224 is located in Areas 02, 03, 05, 06, 11, and 23 of the Nevada Test Site, which is situated approximately 65 miles northwest of Las Vegas, Nevada. CAU 224 is listed in the Federal Facility Agreement and Consent Order (FFACO) of 1996 as Decon Pad and Septic Systems and is comprised of the following nine Corrective Action Sites (CASs): CAS 02-04-01, Septic Tank (Buried); CAS 03-05-01, Leachfield; CAS 05-04-01, Septic Tanks (4)/Discharge Area; CAS 06-03-01, Sewage Lagoons (3); CAS 06-05-01, Leachfield; CAS 06-17-04, Decon Pad and Wastewater Catch; CAS 06-23-01, Decon Pad Discharge Piping; CAS 11-04-01, Sewage Lagoon; and CAS 23-05-02, Leachfield. The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASs 02-04-01, 03-05-01, 06-03-01, 11-04-01, and 23-05-02 is no further action. As a best management practice, the septic tanks and distribution box were removed from CASs 02-04-01 and 11-04-01 and disposed of as hydrocarbon waste. The NDEP-approved correction action alternative for CASs 05-04-01, 06-05-01, 06-17-04, and 06-23-01 is clean closure. Closure activities for these CASs included removing and disposing of radiologically and pesticide-impacted soil and debris. CAU 224 was closed in accordance with the NDEP-approved CAU 224 Corrective Action Plan (CAP). The closure activities specified in the CAP were based on the recommendations presented in the CAU 224 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2005). This Closure Report documents CAU 224 closure activities. During closure activities, approximately 60 cubic yards (yd3) of mixed waste in the form of soil and debris; approximately 70 yd 3 of sanitary waste in the form of soil, liquid from septic tanks, and concrete debris; approximately 10 yd 3 of hazardous waste in the form of pesticide-impacted soil; approximately 0.5 yd 3 of universal waste in the form of

  5. Elastic modulus of tree frog adhesive toe pads.

    Science.gov (United States)

    Barnes, W Jon P; Goodwyn, Pablo J Perez; Nokhbatolfoghahai, Mohsen; Gorb, Stanislav N

    2011-10-01

    Previous work using an atomic force microscope in nanoindenter mode indicated that the outer, 10- to 15-μm thick, keratinised layer of tree frog toe pads has a modulus of elasticity equivalent to silicone rubber (5-15 MPa) (Scholz et al. 2009), but gave no information on the physical properties of deeper structures. In this study, micro-indentation is used to measure the stiffness of whole toe pads of the tree frog, Litoria caerulea. We show here that tree frog toe pads are amongst the softest of biological structures (effective elastic modulus 4-25 kPa), and that they exhibit a gradient of stiffness, being stiffest on the outside. This stiffness gradient results from the presence of a dense network of capillaries lying beneath the pad epidermis, which probably has a shock absorbing function. Additionally, we compare the physical properties (elastic modulus, work of adhesion, pull-off force) of the toe pads of immature and adult frogs.

  6. Flushable reagent stool blood test

    Science.gov (United States)

    Stool occult blood test - flushable home test; Fecal occult blood test - flushable home test ... This test is performed at home with disposable pads. You can buy the pads at the drug store without ...

  7. IT Does Not Love iPads

    Science.gov (United States)

    Fredette, Michelle

    2013-01-01

    On many campuses, iPads have taken over the hearts and minds of everyone. Everyone, that is, except the IT department. These sexy tablets might be the apple of faculty and students' eyes, but for IT directors and their staffs, working with iPads in an enterprise network environment is not the stuff of a love affair. To state the problem…

  8. Enter the iPad (or Not?)

    Science.gov (United States)

    Waters, John K.

    2010-01-01

    Few computing devices have sparked the burning gizmo lust ignited by the iPad. Apple's latest entry into the tablet PC market didn't generate much heat when it was first unveiled in January, but by April 3, the day of the official release, feverish customers were mobbing Apple stores. The company claims to have sold 300,000 iPads by midnight on…

  9. Internal strain estimation for quantification of human heel pad elastic modulus: A phantom study.

    Science.gov (United States)

    Holst, Karen; Liebgott, Hervé; Wilhjelm, Jens E; Nikolov, Svetoslav; Torp-Pedersen, Søren T; Delachartre, Philippe; Jensen, Jørgen A

    2013-02-01

    Shock absorption is the most important function of the human heel pad. However, changes in heel pad elasticity, as seen in e.g. long-distance runners, diabetes patients, and victims of Falanga torture are affecting this function, often in a painful manner. Assessment of heel pad elasticity is usually based on one or a few strain measurements obtained by an external load-deformation system. The aim of this study was to develop a technique for quantitative measurements of heel pad elastic modulus based on several internal strain measures from within the heel pad by use of ultrasound images. Nine heel phantoms were manufactured featuring a combination of three heel pad stiffnesses and three heel pad thicknesses to model the normal human variation. Each phantom was tested in an indentation system comprising a 7MHz linear array ultrasound transducer, working as the indentor, and a connected load cell. Load-compression data and ultrasound B-mode images were simultaneously acquired in 19 compression steps of 0.1mm each. The internal tissue displacement was for each step calculated by a phase-based cross-correlation technique and internal strain maps were derived from these displacement maps. Elastic moduli were found from the resulting stress-strain curves. The elastic moduli made it possible to distinguish eight of nine phantoms from each other according to the manufactured stiffness and showed very little dependence of the thickness. Mean elastic moduli for the three soft, the three medium, and the three hard phantoms were 89kPa, 153kPa, and 168kPa, respectively. The combination of ultrasound images and force measurements provided an effective way of assessing the elastic properties of the heel pad due to the internal strain estimation. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. A solution for the inner area of CBM-TOF with pad-MRPC

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y. [Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Huang, X.J., E-mail: huangxj12@mails.tsinghua.edu.cn [Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Lyu, P.F.; Han, D.; Xie, B.; Li, Y.J. [Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Herrmann, N.; Deppner, I.; Loizeau, P.; Simon, C. [Physikalisches Institute, University Heidelberg, Heidelberg (Germany); Frühauf, J.; Kiš, M. [GSI Helmholtzzentrum fr Schwerionenforschung, GSI, Damstadt (Germany)

    2017-02-11

    The Compressed Baryonic Matter (CBM) experiment has decided to use the Multi-gap Resistive Plate Chambers(MRPC) technology to build its Time-Of-Flight (TOF) wall. CBM-TOF requires a rate capability over 20 kHz/cm{sup 2} for inner region. A 10-gap pad-MRPC assembled with low resistive glass is designed to construct this area. The prototypes, which consist of 10×0.22 mm gas gaps and 2×8 20 mm×20 mm readout pads, require fewer electronic channels compared to the strip design. A timing resolution of around 60 ps and an efficiency above 98% were obtained in a cosmic test and a beam test taken in 2014 October GSI beam time. The results show that the real-size prototypes fulfill the requirements of the CBM-TOF.

  11. Assessment of the Apple iPad as a low-vision reading aid.

    Science.gov (United States)

    Morrice, E; Johnson, A P; Marinier, J-A; Wittich, W

    2017-06-01

    PurposeLow-vision clients frequently report having problems with reading. Using magnification, reading performance (as measured by reading speed) can be improved by up to 200%. Current magnification aids can be expensive or bulky; therefore, we explored if the Apple iPad offers comparable performance in improving reading speeds, in comparison with a closed-circuit television (CCTV) video magnifier, or other magnification devices.MethodsWe recruited 100 participants between the ages of 24-97 years, with low vision who were literate and cognitively capable, of whom 57 had age-related macular degeneration. To assess reading, participants read standardized iReST texts and were tested for comprehension. We compared reading speed on the Apple iPad (10 inch) with that of the CCTV, home magnification devices, and baseline measures.ResultsAll assistive devices improved reading rates in comparison to baseline (P1), however, there was no difference in improvement across devices (P>0.05, Hedge's gread, on average, 30 words per minute faster than first time iPad users, whereas CCTV experience did not influence reading speed.ConclusionsIn our sample, the Apple iPad was as effective as currently used technologies for improving reading rates. Moreover, exposure to, and experience with the Apple iPad might increase reading speed with that device. A larger sample size, however, is needed to do subgroup analysis on who would optimally benefit from each type of magnification device.

  12. Pad readout for gas detectors using 128-channel integrated preamplifiers

    International Nuclear Information System (INIS)

    Fischer, P.; Drees, A.; Glassel, P.

    1988-01-01

    A novel two-dimensional readout scheme for gas detectors is presented which uses small metal pads with 2.54 mm pitch as an anode. The pads are read out via 128-channel VLSI low-noise preamplifier/multiplexer chips. These chips are mounted on 2.8x2.8 cm/sup 2/ modules which are directly plugged onto the detector backplane, daisy-chained with jumpers and read out sequentially. The readout has been successfully tested with a low-pressure, two-step, TMAE-filled UV-RICH detector prototype. A single electron efficiently of >90% was observed at moderate chamber gains (<10/sup 6/). The method offers high electronic amplification, low noise, and high readout speed with a very flexible and compact design, suited for space-limited applications

  13. iPad use in Iowa Research Network family physician offices.

    Science.gov (United States)

    Daly, Jeanette M; Xu, Yinghui; Levy, Barcey T

    2015-04-01

    Through a cancer research infrastructure building grant, iPads were given to health care providers in family physician offices. The purpose of this study was to determine the use and application of iPads in the Iowa Research Network. A Qualtrics survey was sent to 81 iPad recipients after institutional review board approval. Fifty-nine percent responded and 85% reported they have used the iPad. The main reason for use of the iPad was browsing the World Wide Web for health care information. Open-ended comments supported use of the iPad for photographic documentation of wound and other skin lesions for insertion into the medical record and it helped improve clinic flow by making it easier to put orders in the system through the iPad. Tablet uses are variable in physician offices with provider's gathering health care information from the Internet and securing education material for patients as the frequent usages. © The Author(s) 2014.

  14. A French Translation of the Pleasure Arousal Dominance (PAD Semantic Differential Scale for the Measure of Affect and Drive

    Directory of Open Access Journals (Sweden)

    Sandrine Detandt

    2017-03-01

    Full Text Available Multivariate studies have repeatedly confirmed that three basic dimensions of human emotional behavior, called 'pleasure' (P, 'arousal' (A and 'dominance '(D are persistent in organizing human judgments for a wide range of perceptual and symbolic stimuli. The Mehrabian and Russell’s PAD semantic differential scale is a well-established tool to measure these categories, but no standardized French translation is available for research. The aim of this study was to validate a French version of the PAD. For this purpose, (1 Mehrabian and Russell’s PAD was trans- lated through a process of translations and back-translations and (2 this French PAD was tested in a population of 111 French-speaking adults on 21 images of the International Affective Picture System (IAPS. A confirmatory factor analysis revealed the expected three-factor structure; the French PAD also distributed the images in the affective space according to the expected boomerang-shape. The present version of PAD is thus a valid French translation of Mehrabian and Russell’s original PAD.

  15. Stretchable touch-sensing skin over padding for co-robots

    International Nuclear Information System (INIS)

    Chen, Ying; Yu, Miao; Bruck, Hugh A; Smela, Elisabeth

    2016-01-01

    For robots that work collaboratively with people, often referred to as ‘co-robots’, it would be beneficial for them to be soft or padded and to have a touch-sensing ‘skin’ to enable tactile environmental awareness. However, a sensing skin over a padding material that undergoes large deformations requires ‘stretchable’ materials, which may possess time-dependent or viscoelastic mechanical responses. In this work the roles that a padding layer plays when placed under a stretchable sensing layer was investigated. A strain-sensing skin was formed by coating a thin film of compliant piezoresistive sensing paint, consisting of exfoliated graphite in latex, onto a rubber membrane, and the response of the skin was characterized. The change in resistance was linear with tensile strain. The role of the padding material was then investigated under indentation by examining three foams and two elastomers. As expected, the padding enhanced energy dissipation as shown by hysteresis in the sensor response, which is linked to its protective function; the hysteresis was comparable for the five padding materials. The padding also provided an unexpected advantage: it magnified the change in resistance compared to that obtained under free displacement in air. While hysteresis in viscoelastic materials can largely be handled with an appropriate model, inconsistency cannot be, and the two elastomers were found to have unacceptably high variability because of micro-cracks and other defects in these materials. On the other hand, foams that had few defects and regular cell sizes gave good consistency across trials and different sensor positions over the padding. Combined with their lighter weight and availability in a wide range of stiffness, we conclude that foams make a better choice for padding of co-robots. (paper)

  16. Biomechanical Comparison of Shorts With Different Pads: An Insight into the Perineum Protection Issue.

    Science.gov (United States)

    Marcolin, Giuseppe; Petrone, Nicola; Reggiani, Carlo; Panizzolo, Fausto A; Paoli, Antonio

    2015-07-01

    An intensive use of the bicycle may increase the risk of erectile dysfunction and the compression of the perineal area has been showed to be a major mechanism leading to sexual alterations compromising the quality of life. Manufacturers claim that pads contribute to increase cyclists perineal protection ensuring a high level of comfort. To investigate the influence of various cycling pads with regard to perineal protection and level of comfort. Nine club road cyclists rode 20 min on a drum simulator, located at the Nutrition and Exercise Physiology Laboratory, at a constant speed and gear ratio wearing the shorts with 3 cycling pads of different design and thickness: basic (BAS), intermediate (INT), and endurance (END). Kinematics and pressure data were recorded at min 5, 15, and 20 of the test using a motion capture system and a pressure sensor mat. The variables of interest were: 3-dimensional pelvis excursions, peak pressure, mean pressure, and vertical force. The comfort level was assessed with a ranking order based on the subjects' perception after the 20-min trials and measuring the vertical ground reaction force under the anterior wheel as well as the length of the center of pressure (COP) trajectory on the saddle. Results showed that the vertical force and the average value of mean pressure on the saddle significantly decreased during the 20-min period of testing for BAS and END. Mean peak pressure on the corresponding perineal cyclist area significantly increased only for BAS during the 20-min period. Interestingly objective comfort indexes measured did not match cyclists subjective comfort evaluation. The lower capacity of BAS to reduce the peak pressure on the corresponding perineal area after 20 min of testing, together with its positive comfort evaluation, suggest that a balance between protection and perceived comfort should be taken into account in the choice of the pad. Hence, the quantitative approach of objective comfort indexes introduced in this

  17. Analysis of a hypothetical dropped spent nuclear fuel shipping cask impacting a floor mounted crush pad

    International Nuclear Information System (INIS)

    Hawkes, B.D.; Uldrich, E.D.

    1998-03-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of a hypothetically dropped spent nuclear fuel shipping cask into a 44-ft. deep cask unloading pool at the Idaho Chemical Processing Plant. The 110-ton Large Cell Cask was assumed to be accidentally dropped onto the parapet of the unloading pool, causing the cask to tumble through the pool water and impact the floor mounted crush pad with the cask's top corner. The crush pad contains rigid polyurethane foam, which was modeled in a separate computer analysis to simulate the manufacturer's testing of the foam and to determine the foam's stress and strain characteristics. This computer analysis verified that the foam was accurately represented in the analysis to follow. A detailed non-linear, dynamic finite element analysis was then performed on the crush pad and adjacent pool structure to assure that a drop of this massive cask does not result in unacceptable damage to the storage facility. Additionally, verification was made that the crush pad adequately protects the cask from severe impact loading. At impact, the cask has significant vertical, horizontal and rotational velocities. The crush pad absorbs much of the energy of the cask through plastic deformation during primary and secondary impacts. After the primary impact with the crush pad, the cask still has sufficient energy to rebound and rotate until it impacts the pool wall. An assessment is made of the damage to the crush pad and pool wall and of the impact loading on the cask

  18. Teach yourself visually the new iPad

    CERN Document Server

    Watson, Lonzell

    2012-01-01

    A new edition of a bestseller, fully updated on the latest features of the iPad! The evolution of the iPad continues to deliver amazing possibilities, which is exactly why this bestselling guide evolves right along with it! Fully updated with coverage on the latest generation of the iPad, this full-color, step-by-step guide is perfectly suited for anyone who is a visual learner and learns best by visual cues and a tactile interface. You'll learn to access and download books, apps, music, and video content as well as send photos and emails, sync with other devices and services, and confidently

  19. POST-CLOSURE INSPECTION REPORT FOR CORRECTIVE ACTION UNIT 92: AREA 6 DECON PAD FACILITY, NEVADA. TEST SITE NEVADA, FOR THE PERIOD JANUARY 2004 - DECEMBER 2004

    International Nuclear Information System (INIS)

    BECHTEL NEVADA

    2005-01-01

    This Post-Closure Inspection Report provides an analysis and summary of inspections for Corrective Action Unit (CAU) 92, Area 6 Decon Pond Facility, Nevada Test Site, Nevada. CAU 92 was closed in accordance with the Resource Conservation and Recovery Act (RCRA) Part B Operational Permit (Nevada Division of Environmental Protection, 1995) and the Federal Facility Agreement and Consent Order of 1996 on May 11, 1999. CAU 92 consists of two Corrective Action Sites (CASs): CAS 06-04-01, Decon Pad oil/Water Separator; and CAS 06-05-02, Decontamination Pond (RCRA). Both CASs have use restrictions; however, only CAS 06-05-02, Decontamination Pond (RCRA), requires post-closure inspections. CAS 06-04-01, Decon Pad Oil/Water Separator, is located inside the fence at the Building 6-605 compound. This report covers the annual period January 2004 through December 2004

  20. Surface-modified polymeric pads for enhanced performance during chemical mechanical planarization

    International Nuclear Information System (INIS)

    Deshpande, S.; Dakshinamurthy, S.; Kuiry, S.C.; Vaidyanathan, R.; Obeng, Y.S.; Seal, S.

    2005-01-01

    The chemical mechanical planarization (CMP) process occurs at an atomic level at the slurry/wafer interface and hence slurries and polishing pads play a critical role in their successful implementation. Polyurethane is a commonly used polymer in the manufacturing of CMP pads. These pads are incompatible with some chemicals present in the CMP slurries, such as hydrogen peroxide. To overcome these problems, Psiloquest has developed new Application Specific Pads (ASP). Surface of such pads has been modified by depositing a thin film of tetraethyl orthosilicate using plasma-enhanced chemical vapor deposition (PECVD) process. In the present study, mechanical properties of such coated pads have been investigated using nanoindentation. The surface morphology and the chemistry of the ASP were studied using scanning electron microcopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy techniques. It was observed that mechanical and chemical properties of the pad top surface are a function of the PECVD coating time. Such PECVD-treated pads are found to be hydrophilic and do not require storage in aqueous media during the not-in-use period. The metal removal rate using such surface-modified polishing pads was found to increase linearly with the PECVD coating time

  1. 21 CFR 884.5435 - Unscented menstrual pad.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Unscented menstrual pad. 884.5435 Section 884.5435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5435 Unscented menstrual pad. (a)...

  2. Student Perceptions of Classroom Engagement and Learning using iPads

    OpenAIRE

    Jefferson W. Streepey; Eugenia Fernandez; Timothy T. Diemer

    2013-01-01

    Many colleges and universities have launched iPad initiatives in an effort to enhance student learning. Despite their rapid adoption, the extent to which iPads increase student engagement and learning is not well understood. This paper reports on a multidisciplinary assessment of student perceptions of engagement and learning using iPads. Student reactions following single and multiple classroom activities using iPads were measured via a survey asking them to rate their learning and engagemen...

  3. Pilot Study of iPad Incorporation Into Graduate Medical Education.

    Science.gov (United States)

    Lobo, Mark J; Crandley, Edwin F; Rumph, Jake S; Kirk, Susan E; Dunlap, Neal E; Rahimi, Asal S; Turner, A Benton; Larner, James M; Read, Paul W

    2013-03-01

    Increased documentation and charting requirements are challenging for residents, given duty hour limits. Use of mobile electronic devices may help residents complete these tasks efficiently. To collect initial data on usage rates, information technology (IT) support requirements, and resident use of iPads during training. In this pilot study, we provided 12 residents/fellows from various specialties at the University of Virginia with an iPad with IT support. The system used a virtual private network with access to the institution's electronic health record. Participants were allowed to develop their own methods and systems for personalized iPad use, and after 9 months they provided data on the utility of the iPad. Feedback from the IT team also was obtained. Average iPad use was 2.1 h/d (range, 0.5-6 h/d). The average self-reported reduction in administrative work due to the iPad was 2.7 h/wk (range, 0-9 h/wk). A total of 75% (9 of 12) of the users would recommend universal adoption among residents and fellows. More than 90% (11 of 12) of users reported the iPad would improve communication for coordination of care. A total of 68% (8 of 12) of users reported that an iPad facilitated their activities as educators of medical students and junior residents. Residents cited slow data entry into the electronic health record and hospital areas lacking Wi-Fi connectivity as potential drawbacks to iPad use. The IT team reported minimal support time for device setup, maintenance, and upgrades, and limited security risks. The iPad may contribute to increased clinical efficiency, reduced hours spent on administrative tasks, and enhanced educational opportunities for residents, with minimal IT support.

  4. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings: Part II – Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar

    2006-01-01

    This is Part II of a two-part series of papers describing the effects of high pressure injection pockets on the operating conditions of tilting-pad thrust bearings. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approximately...... 100 cm2 surface area. Two pads are measured in a laboratory test-rig at loads of approximately 0.5, 1.5 and 4.0 MPa and velocities of up to 33 m/s. One pad has a plain surface. The other pad has a conical injection pocket at the pivot point and a leading edge taper. The measurements are compared...... to theoretical values obtained using a three dimensional thermo-elasto-hydrodynamic (TEHD) numerical model. At low and intermediate loads the theoretical pressure distribution corresponds well to the measured values for both pads although the influence of the pocket is slightly underestimated. At high loads...

  5. Study on natural convection in core barrel. Experimental and numerical results for band type spacer pads

    International Nuclear Information System (INIS)

    Hayashi, Kenji; Kawamata, Nobuhiro; Kamide, Hideki

    2003-03-01

    In a fast reactor an Inter-Wrapper Flow (IWF) is one of significant phenomena for decay heat removal under natural circulation condition, when a direct reactor auxiliary cooling system (DRACS) is adopted for decay heat removal system. Cold coolant provided by dipped heat exchangers (DHX) of DRACS can penetrate into the core barrel (region between the subassemblies) and it makes natural convection int he core barrel. Such IWF will depend on a spacer pad geometry of subassemblies. Water experiment, TRIF (Test Rig for Inter-wrapper Flow), was carried out for IWF in a reactor core. The test section modeled a 1/12th sector of the core and upper plenum of reactor vessel. Experimental parameters were the spacer pad geometry and flow path geometries connecting the upper plenum and core barrel. Numerical simulation using AQUA code was also performed to confirm applicability of a simulation method. An experimental series using a button type spacer pad had been carried out. Here a band type spacer pad was examined. Temperatures at subassembly wall were measured with parameter of the flow path geometries; one was a connection pipe between the upper plenum and core barrel and the other was flow hole in core former plates between the outermost subassemblies and the core barrel. It was found that these flow paths were effective to remove heat in the core in case of the band type spacer pad. A general purpose three dimensional analysis code, AQUA, was applied to the experimental analysis. Each subassembly and inter wrapper gap region were modeled by slab mesh geometry. Pressure loss coefficient at the pacer pad was set based on the geometry. The numerical simulation results were in good agreement with measured temperature profiles in the core. (author)

  6. Comparative efficacy of active and passive distraction during restorative treatment in children using an iPad versus audiovisual eyeglasses: a randomised controlled trial.

    Science.gov (United States)

    Attar, R H; Baghdadi, Z D

    2015-02-01

    This study aimed to compare the effects of two types of distraction techniques: passive, using audiovisual glasses (AV glasses), versus active, using an iPad, as an adjunct to local analgesia during vital pulp therapy in children. Pain behaviour, and heart rates from an exposure group (treatment with the aid of an iPad) and control group (treatment with the aid of AV glasses) were compared in a randomised, split-mouth design using the Wilcoxon signed rank test (pain and behaviour) and paired t test for heart rate scores at p 0.05. Children (39) (mean age 6.27 years) received the two treatment sessions. Generally, AV glasses had higher pain and behaviour scores than iPad. Pain results demonstrated marginal significant differences between the two distraction techniques during local analgesia administration (p 0.076) and caries removal (p 0.071). A significant difference between the two techniques during local analgesia administration only (p 0.017), in favour of an iPad. Average heart rates over the treatment intervals were lower among iPad group than those using AV glasses group. Patients preferred an iPad more than AV glasses (24 versus 15). Treatment sessions were significantly shorter for iPad. Active distraction using an iPad demonstrated better performance than passive distraction using AV glasses.

  7. Morphology and properties of periwinkle shell asbestos-free brake pad

    Directory of Open Access Journals (Sweden)

    D.S. Yawas

    2016-01-01

    Full Text Available The development of asbestos-free automotive brake pad using periwinkle shell particles as frictional filler material is presented. This was with a view to exploiting the characteristics of the periwinkle shell, which is largely deposited as a waste, in replacing asbestos which has been found to be carcinogenic. Five sets of brake pads with different sieve size (710–125 μm of periwinkle shell particles with 35% resin were produced using compressive moulding. The physical, mechanical and tribological properties of the periwinkle shell particle-based brake pads were evaluated and compared with the values for the asbestos-based brake pads. The results obtained showed that compressive strength, hardness and density of the developed brake pad samples increased with decreasing the particle size of periwinkle shell from 710 to 125 μm, while the oil soak, water soak and wear rate decreased with decreasing the particle size of periwinkle shell. The results obtained at 125 μm of periwinkle shell particles compared favourably with that of commercial brake pad. The results of this research indicate that periwinkle shell particles can be effectively used as a replacement for asbestos in brake pad manufacture.

  8. Water data: bad TPC pads, 3.6 µs and 100 ns problems

    CERN Document Server

    Dydak, F; Nefedov, Y; Wotschack, J; Zhemchugov, A

    2004-01-01

    Out of the 3972 pads of the HARP TPC, about 9% are 'bad' and not useful for the correct reconstruction of clusters. Bad pads comprise dead pads, noisy pads, and pads with low or undefined amplification. Pads may be bad at one time, but not at another. This memo discusses the sources of information which were used to declare a pad 'bad', and gives the list of bad pads for the water data (runs 19146 to 19301). Also, the 3.6 µs and 100 ns problems of the TPC readout are discussed, including the corrective measures which have been taken.

  9. De implementatie van de iPad in het voortgezet onderwijs

    NARCIS (Netherlands)

    Marjorie Louwsma; Anneke van Zwol; Klaas Jan Huizing

    2012-01-01

    Brengt de iPad in het onderwijs meer gebruiksgemak, snelheid en studievermogen? Sowijs deed onderzoek naar de implementatie van de iPad in het voortgezet onderwijs. Wat is de visie van leerlingen en leraren over de introductie van de iPad en wat zijn belangrijke aanbevelingen?

  10. Effect of temperature on MRPC with pad read-outs

    International Nuclear Information System (INIS)

    Ding Weicheng; Wang Yi; Chen Huangshan; Wang Jingbo; Tuo Xianguo; Wang Min

    2013-01-01

    To obtain a quantitative understanding of the influence of temperature on the performance of multi-gap resistive plate chambers (MRPCs), we have tested the performance of a 10-gap, 12-pad, 2×2×12 cm 2 active area MRPC at different temperatures with cosmic rays. Presented are results from measurements of high-voltage scans, noise rate, dark current, streamer, time resolution, count rate, charge spectrum, and detection efficiency. The test results show that the MRPC performance is significantly affected by temperature arising from the temperature-dependence of the glass resistivity. (authors)

  11. Evaluation of palm kernel fibers (PKFs for production of asbestos-free automotive brake pads

    Directory of Open Access Journals (Sweden)

    K.K. Ikpambese

    2016-01-01

    Full Text Available In this study, asbestos-free automotive brake pads produced from palm kernel fibers with epoxy-resin binder was evaluated. Resins varied in formulations and properties such as friction coefficient, wear rate, hardness test, porosity, noise level, temperature, specific gravity, stopping time, moisture effects, surface roughness, oil and water absorptions rates, and microstructure examination were investigated. Other basic engineering properties of mechanical overload, thermal deformation fading behaviour shear strength, cracking resistance, over-heat recovery, and effect on rotor disc, caliper pressure, pad grip effect and pad dusting effect were also investigated. The results obtained indicated that the wear rate, coefficient of friction, noise level, temperature, and stopping time of the produced brake pads increased as the speed increases. The results also show that porosity, hardness, moisture content, specific gravity, surface roughness, and oil and water absorption rates remained constant with increase in speed. The result of microstructure examination revealed that worm surfaces were characterized by abrasion wear where the asperities were ploughed thereby exposing the white region of palm kernel fibers, thus increasing the smoothness of the friction materials. Sample S6 with composition of 40% epoxy-resin, 10% palm wastes, 6% Al2O3, 29% graphite, and 15% calcium carbonate gave better properties. The result indicated that palm kernel fibers can be effectively used as a replacement for asbestos in brake pad production.

  12. Modelling and simulation of a compliant tilting pad air bearing

    NARCIS (Netherlands)

    Duijnhouwer, F.; Nijmeijer, H.

    The compliant tilting pad air bearing concept, a tilting pad bearing with the pivot of the pads placed on radial springs, is a promising aerodynamic bearing solution. Nevertheless, its non-linear dynamics make a time domain dynamic simulation model an essential tool for the design of rotor systems

  13. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings - Part II: Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2007-01-01

    This is Part II of a two-part series of papers describing the effects of high-pressure injection pockets on the operating conditions of tilting-pad thrust bearings. The paper has two main objectives. One is an experimental investigation of the influence of an oil injection pocket on the pressure...... and without oil injection) on the pressure distribution and oil film thickness. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approx. 100 cm^2 surface area. Two pads are measured in a laboratory test rig at loads of approx. 1.5 MPa...... and approx. 4.0 MPa and velocities of up to 33 m/s. One pad has a plain surface. The other pad has a conical injection pocket at the pivot point and a leading-edge taper. The measurements are compared to theoretical values obtained using a three-dimensional thermoelastohydrodynamic (TEHD) numerical model...

  14. The effectiveness of Lee Silverman Voice Treatment therapy issued interactively through an iPad device: A non-inferiority study.

    Science.gov (United States)

    Griffin, Murray; Bentley, John; Shanks, Joseph; Wood, Carly

    2018-04-01

    Introduction This study compared the differences in recorded speech variables between people treated with conventional 'in person' Lee Silverman Voice Treatment (LSVT) and those treated remotely via iPad-based 'Facetime'. Method Eight participants were selected for the iPad LSVT, and 21 similarly matched subjects were selected from existing data to form the 'in person' group. Participants in both groups had diagnosed idiopathic Parkinson's disease and moderate hypokinetic dysarthria. Eighteen sessions of prescribed LSVT comprising a pre-treatment assessment, 16 treatment sessions, and a six months' post-treatment assessment were administered for each person. In both groups, pre- and post-treatment assessments were conducted face-to-face. Performance measures were recorded during assessment and treatment. Average measures were determined for all tasks at all time points and a summary outcome variable was composed from across-task performance. Results Non-inferiority testing confirmed that iPad LSVT was non-inferior in treating all LSVT task 3 variables except generating words, with the 90% upper confidence intervals (CI) lying between the non-inferiority margin of ± 2.25 and zero. The iPad was superior in treating the task 3 rainbow reading passage and describing motor task variables with upper and lower 90% CI values being negative. The improvement in the summary outcome variable score was also superior in the iPad group. Discussion Non-inferiority testing implies that the iPad LSVT is non-inferior in treating task three variables when compared to traditional LSVT. The study supports further development of remote delivery solutions involving the Apple iPad and 'Facetime' system as a means of improving access to services and the participant's experience.

  15. Kager's fat pad inflammation associated with HIV infection and AIDS: MRI findings

    International Nuclear Information System (INIS)

    Godoy-Santos, Alexandre Leme; Fernandes, Tulio Diniz; Camanho, Gilberto Luis; Bordalo-Rodrigues, Marcelo; Rosemberg, Laercio; Lei Munhoz Lima, Ana Lucia; Maffulli, Nicola

    2014-01-01

    To describe magnetic resonance imaging (MRI) features of Kager's fat pad inflammation in HIV-positive patients with lipodystrophy due to protease inhibitor treatment and posterior ankle pain. A case-control, cross-sectional study; group 1 included 14 HIV-positive patients using protease inhibitors, presenting lipodystrophy syndrome and having posterior ankle pain; group 2 (CGHIV-) included 112 HIV-negative patients without lipodystrophy syndrome who were being evaluated for posterior ankle pain; group 3 (CGHIV + 1) included 23 HIV-positive patients not using a protease inhibitor, without lipodystrophy syndrome and with posterior ankle pain; group 4 (CGHIV + 2) comprised 18 HIV-positive patients who were being treated with a protease inhibitor and had lipodystrophy syndrome but did not have posterior ankle pain. Images were evaluated for the presence of edema by two radiologists who were blinded to clinical features. Fisher's exact test was used to evaluate differences among the groups. Interobserver variation was tested using Cohen's kappa (κ) statistic. The presence of edema within Kager's fat pad was strongly associated with symptoms in HIV-positive patients who had lipodystrophy (p ≤ 0.0001). Concordance between observers was excellent (κ > 0.9). MRI findings of Kager's fat pad inflammation related to HIV/AIDS is a source of symptoms in HIV patients with posterior ankle pain using protease inhibitors and having lipodystrophy syndrome. (orig.)

  16. Roles of PAD4 and NETosis in Experimental Atherosclerosis and Arterial Injury: Implications for Superficial Erosion.

    Science.gov (United States)

    Franck, Grégory; Mawson, Thomas L; Folco, Eduardo J; Molinaro, Roberto; Ruvkun, Victoria; Engelbertsen, Daniel; Liu, Xin; Tesmenitsky, Yevgenia; Shvartz, Eugenia; Sukhova, Galina K; Michel, Jean-Baptiste; Nicoletti, Antonino; Lichtman, Andrew; Wagner, Denisa; Croce, Kevin J; Libby, Peter

    2018-06-22

    Neutrophils likely contribute to the thrombotic complications of human atheromata. In particular, neutrophil extracellular traps (NETs) could exacerbate local inflammation and amplify and propagate arterial intimal injury and thrombosis. PAD4 (peptidyl arginine deiminase 4) participates in NET formation, but an understanding of this enzyme's role in atherothrombosis remains scant. This study tested the hypothesis that PAD4 and NETs influence experimental atherogenesis and in processes implicated in superficial erosion, a form of plaque complication we previously associated with NETs. Bone marrow chimeric Ldlr deficient mice reconstituted with either wild-type or PAD4-deficient cells underwent studies that assessed atheroma formation or procedures designed to probe mechanisms related to superficial erosion. PAD4 deficiency neither retarded fatty streak formation nor reduced plaque size or inflammation in bone marrow chimeric mice that consumed an atherogenic diet. In contrast, either a PAD4 deficiency in bone marrow-derived cells or administration of DNaseI to disrupt NETs decreased the extent of arterial intimal injury in mice with arterial lesions tailored to recapitulate characteristics of human atheroma complicated by erosion. These results indicate that PAD4 from bone marrow-derived cells and NETs do not influence chronic experimental atherogenesis, but participate causally in acute thrombotic complications of intimal lesions that recapitulate features of superficial erosion. © 2018 American Heart Association, Inc.

  17. Test of multi-anode photomultiplier tubes for the LHCb scintillator pad detector

    CERN Document Server

    Aguiló, Ernest; Comerma-Montells, A; Garrido, Lluis; Gascon, David; Graciani, Ricardo; Grauges, Eugeni; Vilasis Cardona, Xavier; Xirgu, Xavier; Bohner, Gerard; Bonnefoy, Romeo; Borras, David; Cornat, Remi; Crouau, Michel; Deschamps, Olivier; Jacquet, Philippe; Lecoq, Jacques; Monteil, Stephane; Perret, Pascal; Reinmuth, Guy

    2005-01-01

    The LHCb experiment (The LHCb Technical Proposal, CERN/LHCC 98-4) is designed to study B meson physics in the LHC proton-proton collider at CERN. The Scintillator Pad Detector (SPD) has been designed to complete the calorimeter information performing an e/gamma identification for the experiment level-0 trigger system. The detection technology consists in transmitting scintillation light by means of both Wavelength Shifting and clear fibers to fast multi- anode photomultiplier tubes. In this paper, it is described the instrumentation and setup used to characterize the baseline photomultiplier solution (Hamamatsu R5900-00-M64) together with the scintillators and optical fibers for the SPD at LHCb.

  18. Exploring anatomy and physiology using iPad applications.

    Science.gov (United States)

    Chakraborty, Tandra R; Cooperstein, Deborah F

    2017-11-07

    This study examined the use of iPads with anatomy applications (apps) in the laboratory sections of the largest undergraduate course at the university, Anatomy and Physiology, serving more than 300 students. The majority of these students were nursing, exercise science/physical education and biology majors. With a student survey (student opinion) and student practicum grades as metrics, this study determined whether the introduction of this novel mobile technology improved student grades and aided the students in learning the course material. The results indicated that students' grades improved with the introduction of the iPads, and 78% of the students reported that the iPads facilitated their ability to learn the course material. There was a positive association between frequency of app use and standardized mastery of the course material, as students who used the apps more frequently scored higher and indicated that they felt as though they had learned the material more comprehensively. Owning or having an iPad at home did not have a significant effect on the learning of the material. The general consensus by students was that iPad anatomy apps should be used frequently to better develop student understanding of the course material. Anat Sci Educ. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  19. Nature and Extent of iPad Use among Freshmen Honors Students

    Science.gov (United States)

    Maxwell, Patricia; Banerjee, Priya

    2013-01-01

    On the heels of national studies reporting that college students believe tablet computers will "transform" learning, many colleges have begun to use mobile technology like the iPad and laptop as recruitment tools. The effectiveness of such incentives can be tested by determining whether enrollment increased as a result, and whether or…

  20. Characterization of thermoset and thermoplastic polyurethane pads, and molded and non-optimized machined grooving methods for oxide chemical mechanical planarization applications

    International Nuclear Information System (INIS)

    Sampurno, Yasa; Borucki, Leonard; Zhuang, Yun; Misra, Sudhanshu; Holland, Karey; Boning, Duane; Philipossian, Ara

    2009-01-01

    This paper systematically studies the effect of pad material, grooving method and grooving pattern on interlayer dielectric chemical mechanical planarization. The tested polishing pads consist of thermoplastic and thermoset polyurethanes synthesized using two different processes. Grooves created using a molding technique are compared with grooves formed by mechanical cutting. The concentric groove design is also compared with the logarithmic positive spiral positive grooving design. Experimental data collected include removal rate, coefficient of friction, shear force variance, pad temperature and dynamic mechanical analyzer measurements. Scanning electron microscope images are used to correlate grooving methods with coefficient of friction and shear force variance measurements. Results show that all of the pads polish wafers in boundary lubrication mode with unique friction coefficient, shear force variance and pad temperature characteristics. Simulations using a two-step removal rate mechanism are performed to estimate the chemical and mechanical rate constants. The analysis indicates that the thermoplastic pad is more mechanically controlled than the thermoset pad and that molded grooving induces a more mechanically controlled process than non-optimized machined grooving

  1. On the Controllability and Observability of Actively Lubricated Journal Bearings with Pads Featuring Different Nozzle-Pivot Configurations

    DEFF Research Database (Denmark)

    Salazar, Jorge Andrés González; Santos, Ilmar

    2017-01-01

    tilt angle, (iii) the vertical pad movement-due to the pivot flexibility, and (iv) the controllable force as the hydraulic DOF. The test rig consists of a rigid rotor supported by a single rocker-pivoted rigid pad. A thorough parametric study is carried out by investigating the effects of: (a) nozzle-pivot...... offset, (b) pivot flexibility, and (c) bearing loading on these control basics in order to determine the pad with the best control characteristics. Different nozzle-pivot offsets can be set by varying the positioning of either the injection nozzle or the pivot line. The influence of the pivot compliance...... on the bearing dynamics is assessed by benchmarking the results obtained with the flexible pivot against the rigid pivot. Three different bearing loads are studied. According to the results, the proposed configurations, especially the offset-pivot pad with slight offsets, improve the bearing control...

  2. Computerized spiral analysis using the iPad.

    Science.gov (United States)

    Sisti, Jonathan A; Christophe, Brandon; Seville, Audrey Rakovich; Garton, Andrew L A; Gupta, Vivek P; Bandin, Alexander J; Yu, Qiping; Pullman, Seth L

    2017-01-01

    Digital analysis of writing and drawing has become a valuable research and clinical tool for the study of upper limb motor dysfunction in patients with essential tremor, Parkinson's disease, dystonia, and related disorders. We developed a validated method of computerized spiral analysis of hand-drawn Archimedean spirals that provides insight into movement dynamics beyond subjective visual assessment using a Wacom graphics tablet. While the Wacom tablet method provides robust data, more widely available mobile technology platforms exist. We introduce a novel adaptation of the Wacom-based method for the collection of hand-drawn kinematic data using an Apple iPad. This iPad-based system is stand-alone, easy-to-use, can capture drawing data with either a finger or capacitive stylus, is precise, and potentially ubiquitous. The iPad-based system acquires position and time data that is fully compatible with our original spiral analysis program. All of the important indices including degree of severity, speed, presence of tremor, tremor amplitude, tremor frequency, variability of pressure, and tightness are calculated from the digital spiral data, which the application is able to transmit. While the iPad method is limited by current touch screen technology, it does collect data with acceptable congruence compared to the current Wacom-based method while providing the advantages of accessibility and ease of use. The iPad is capable of capturing precise digital spiral data for analysis of motor dysfunction while also providing a convenient, easy-to-use modality in clinics and potentially at home. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. 78 FR 694 - Proposed Extension of Approval of Information Collection; Comment Request-Testing and...

    Science.gov (United States)

    2013-01-04

    ... ignition of mattresses, 16 CFR part 1632. The Open- Flame standard is intended to reduce unreasonable risks... may be introduced into commerce. The Office of Management and Budget (OMB) previously approved the... suppliers, and confirmation test records, if establishments choose to pool a prototype. This documentation...

  4. Fibrous scar in the infrapatellar fat pad after arthroscopy. MR imaging

    International Nuclear Information System (INIS)

    Tang, Guangyu; Niitsu, Mamoru; Ikeda, Kotaro; Itai, Yuji; Endo, Hideho

    2000-01-01

    We describe the MR appearance of fibrous scars in the infrapatellar fat pad after arthroscopy. The subjects were 96 patients who underwent arthroscope-assisted anterior cruciate ligament (ACL) reconstruction and were examined by oblique sagittal MR imaging at different follow-up intervals. Two observers evaluated the characteristics of the fibrous scars in the infrapatellar fat pad. All fibrous scars with low signal intensity were accentuated at the portal and coursed horizontally through the infrapatellar fat pad. The fibrous scar within the fat pad occurred and peaked within 6 months after arthroscopy. It then subsided gradually and had disappeared by one year later in nearly half of the patients. Identifying MR imaging characteristics of fibrous scars in the fat pad after arthroscopy may be clinically helpful to differentiate these scars from other abnormalities that involve the infrapatellar fat pad. (author)

  5. Fibrous scar in the infrapatellar fat pad after arthroscopy. MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Guangyu; Niitsu, Mamoru; Ikeda, Kotaro; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Endo, Hideho

    2000-02-01

    We describe the MR appearance of fibrous scars in the infrapatellar fat pad after arthroscopy. The subjects were 96 patients who underwent arthroscope-assisted anterior cruciate ligament (ACL) reconstruction and were examined by oblique sagittal MR imaging at different follow-up intervals. Two observers evaluated the characteristics of the fibrous scars in the infrapatellar fat pad. All fibrous scars with low signal intensity were accentuated at the portal and coursed horizontally through the infrapatellar fat pad. The fibrous scar within the fat pad occurred and peaked within 6 months after arthroscopy. It then subsided gradually and had disappeared by one year later in nearly half of the patients. Identifying MR imaging characteristics of fibrous scars in the fat pad after arthroscopy may be clinically helpful to differentiate these scars from other abnormalities that involve the infrapatellar fat pad. (author)

  6. Analysis of the gas-lubricated flat-sector-pad thrust bearing

    Science.gov (United States)

    Etsion, I.

    1976-01-01

    A flat sector-shaped pad geometry for a gas-lubricated thrust bearing is analyzed considering both the pitch and roll of the pad. It is shown that maximum load capacity is achieved when the pad is tilted so as to create uniform minimum film thickness along the pad trailing edge. Performance characteristics for various geometries and operating conditions of gas thrust bearings are presented in the form of design curves, and a comparison is made with the rectangular slider approximation. It is found that this approximation is unsafe for practical design, since it always overestimates load capacity.

  7. Eye/head tracking technology to improve HCI with iPad applications.

    Science.gov (United States)

    Lopez-Basterretxea, Asier; Mendez-Zorrilla, Amaia; Garcia-Zapirain, Begoña

    2015-01-22

    In order to improve human computer interaction (HCI) for people with special needs, this paper presents an alternative form of interaction, which uses the iPad's front camera and eye/head tracking technology. With this functional nature/capability operating in the background, the user can control already developed or new applications for the iPad by moving their eyes and/or head. There are many techniques, which are currently used to detect facial features, such as eyes or even the face itself. Open source bookstores exist for such purpose, such as OpenCV, which enable very reliable and accurate detection algorithms to be applied, such as Haar Cascade using very high-level programming. All processing is undertaken in real time, and it is therefore important to pay close attention to the use of limited resources (processing capacity) of devices, such as the iPad. The system was validated in tests involving 22 users of different ages and characteristics (people with dark and light-colored eyes and with/without glasses). These tests are performed to assess user/device interaction and to ascertain whether it works properly. The system obtained an accuracy of between 60% and 100% in the three test exercises taken into consideration. The results showed that the Haar Cascade had a significant effect by detecting faces in 100% of cases, unlike eyes and the pupil where interference (light and shade) evidenced less effectiveness. In addition to ascertaining the effectiveness of the system via these exercises, the demo application has also helped to show that user constraints need not affect the enjoyment and use of a particular type of technology. In short, the results obtained are encouraging and these systems may continue to be developed if extended and updated in the future.

  8. Perceptions and use of iPad technology by pharmacy practice faculty members.

    Science.gov (United States)

    DiVall, Margarita V; Zgarrick, David P

    2014-04-17

    To explore the potential of tablet technology to address the specific workload challenges of pharmacy practice faculty members and to evaluate tablet usage after a department-wide iPad initiative. After conducting a needs assessment to determine pharmacy faculty attitudes towards tablet technology and to identify potential usage scenarios, all faculty members in a department of pharmacy practice received an iPad. After iPad distribution, training sessions and virtual tutorials were provided. An anonymous survey was administered to evaluate the pilot. The needs assessment survey revealed positive attitudes towards iPad technology, identified use scenarios, and led to a department-wide iPad pilot program. Most faculty members used iPads for connectivity with students (86%), paper/project annotation (68%), assessment (57%), and demonstration of tools used in practice (36%). For teaching, 61% of faculty members used iPads in seminars/laboratories, 57% used iPads in the experiential setting, and 43% used iPads in the classroom. Use of iPads for patient-care activities varied and depended on site support for mobile technology. The 23 faculty members with external practice sites used iPads to a greater extent and had more positive attitudes towards this technology compared with campus-based faculty members. Integration of tablet technology into the pharmacy education setting resulted in faculty-reported increased productivity and decreased paper waste. It also allowed faculty members to experiment with new teaching strategies in the classroom and experiential setting. Administrators at institutions exploring the use of tablet technology should allocate resources based on faculty needs and usage patterns.

  9. Parasympathetic neurons in the cranial medial ventricular fat pad on the dog heart selectively decrease ventricular contractility.

    Science.gov (United States)

    Dickerson, L W; Rodak, D J; Fleming, T J; Gatti, P J; Massari, V J; McKenzie, J C; Gillis, R A

    1998-05-28

    We hypothesized that selective control of ventricular contractility might be mediated by postganglionic parasympathetic neurons in the cranial medial ventricular (CMV) ganglion plexus located in a fat pad at the base of the aorta. Sinus rate, atrioventricular (AV) conduction (ventricular rate during atrial pacing), and left ventricular contractile force (LV dP/dt during right ventricular pacing) were measured in eight chloralose-anesthetized dogs both before and during bilateral cervical vagus stimulation (20-30 V, 0.5 ms pulses, 15-20 Hz). Seven of these dogs were tested under beta-adrenergic blockade (propranolol, 0.8 mg kg(-1) i.v.). Control responses included sinus node bradycardia or arrest during spontaneous rhythm, high grade AV block or complete heart block, and a 30% decrease in contractility from 2118 +/- 186 to 1526 +/- 187 mm Hg s(-1) (P 0.05) decrease in contractility but still elicited the same degree of sinus bradycardia and AV block (N = 8, P < 0.05). Five dogs were re-tested 3 h after trimethaphan fat pad injection, at which time blockade of vagally-induced negative inotropy was partially reversed, as vagal stimulation decreased LV dP/dt by 19%. The same dose of trimethaphan given either locally into other fat pads (PVFP or IVC-ILA) or systemically (i.v.) had no effect on vagally-induced negative inotropy. Thus, parasympathetic ganglia located in the CMV fat pad mediated a decrease in ventricular contractility during vagal stimulation. Blockade of the CMV fat pad had no effect on vagally-mediated slowing of sinus rate or AV conduction.

  10. Pad use and patient reported bother from urinary leakage after radical prostatectomy.

    Science.gov (United States)

    Wallerstedt, Anna; Carlsson, Stefan; Nilsson, Andreas E; Johansson, Eva; Nyberg, Tommy; Steineck, Gunnar; Wiklund, N Peter

    2012-01-01

    To better understand clinically significant definitions of urinary incontinence we investigated the relationship between urinary leakage and patient reported bother from urinary leakage. A consecutive series of 1,411 men who underwent radical prostatectomy at Karolinska University Hospital, Stockholm, Sweden, from 2002 to 2006 were invited to complete a study specific questionnaire with questions on pad status, urinary leakage and bother from urinary leakage. Questionnaires were received from 1,179 men with a followup of greater than 1 year (median 2.2). Results showed that even a small amount of urinary leakage resulted in a high risk of urinary bother. Of 775 survivors 46 (6%) reporting 0 pads indicated moderate or much bother compared to 38 of 123 (31%) who reported using a security pad. When comparing the 2 groups, the risk of bother from urinary leakage was more than 5 times higher in the safety pad vs the 0 pad group (RR 5.2, 95% CI 3.5-7.7). As the number of pads increased, we noted a higher bother risk. Cross-tabulation of pad use and urinary leakage revealed wide variation in pad requirements despite the same answer to urinary leakage questions. If the definition of continence is based on pad use, for example safety pads, a certain number of men who report moderate or much bother from urinary leakage will be defined as continent. Our results also show that for each stated rate of urinary leakage men prove to have a major variation in the pad requirement. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Launch Pad Coatings for Smart Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Hintze, Paul E.; Bucherl, Cori N.; Li, Wenyan; Buhrow, Jerry W.; Curran, Jerome P.; Whitten, Mary C.

    2010-01-01

    Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability

  12. Effect of comfort pads and incubator design on neonatal radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A.; Lu, Zhengfeng [University of Chicago Medicine, Department of Radiology, Chicago, IL (United States)

    2016-01-15

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: (1) both the comfort pad and support included in the beam, (2) only the support tray included and (3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient. (orig.)

  13. Effect of comfort pads and incubator design on neonatal radiography

    International Nuclear Information System (INIS)

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A.; Lu, Zhengfeng

    2016-01-01

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: (1) both the comfort pad and support included in the beam, (2) only the support tray included and (3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient. (orig.)

  14. Modeling of Tilting-Pad Journal Bearings with Transfer Functions

    Directory of Open Access Journals (Sweden)

    J. A. Vázquez

    2001-01-01

    Full Text Available Tilting-pad journal bearings are widely used to promote stability in modern rotating machinery. However, the dynamics associated with pad motion alters this stabilizing capacity depending on the operating speed of the machine and the bearing geometric parameters, particularly the bearing preload. In modeling the dynamics of the entire rotor-bearing system, the rotor is augmented with a model of the bearings. This model may explicitly include the pad degrees of freedom or may implicitly include them by using dynamic matrix reduction methods. The dynamic reduction models may be represented as a set of polynomials in the eigenvalues of the system used to determine stability. All tilting-pad bearings can then be represented by a fixed size matrix with polynomial elements interacting with the rotor. This paper presents a procedure to calculate the coefficients of polynomials for implicit bearing models. The order of the polynomials changes to reflect the number of pads in the bearings. This results in a very compact and computationally efficient method for fully including the dynamics of tilting-pad bearings or other multiple degrees of freedom components that interact with rotors. The fixed size of the dynamic reduction matrices permits the method to be easily incorporated into rotor dynamic stability codes. A recursive algorithm is developed and presented for calculating the coefficients of the polynomials. The method is applied to stability calculations for a model of a typical industrial compressor.

  15. Bioluminescent bioreporter pad biosensor for monitoring water toxicity.

    Science.gov (United States)

    Axelrod, Tim; Eltzov, Evgeni; Marks, Robert S

    2016-01-01

    Toxicants in water sources are of concern. We developed a tool that is affordable and easy-to-use for monitoring toxicity in water. It is a biosensor composed of disposable bioreporter pads (calcium alginate matrix with immobilized bacteria) and a non-disposable CMOS photodetector. Various parameters to enhance the sensor's signal have been tested, including the effect of alginate and bacterium concentrations. The effect of various toxicants, as well as, environmental samples were tested by evaluating their effect on bacterial luminescence. This is the first step in the creation of a sensitive and simple operative tool that may be used in different environments. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Parametric studies on floating pad journal bearing for high speed cryogenic turboexpanders

    Science.gov (United States)

    Jain, A.; Jadhav, M. M.; Karimulla, S.; Chakravarty, A.

    2017-12-01

    Most modern medium and large capacity helium liquefaction/refrigeration plants employ high speed cryogenic turboexpanders in their refrigeration/liquefaction cycles as active cooling devices. The operating speed of these turboexpanders is in the range of 3000-5000 Hz and hence specialized types of bearings are required. Floating pad journal bearing, which is a special type of tilting pad journal bearing, where mechanical pivots are absent and pads are fully suspended in gas, can be a good solution for stable operation of these high speed compact rotors. The pads are separated from shaft as well as from housing by fluid film between them, and both these sides of pad are interconnected by a network of feed holes. The work presented in this article aims to characterize floating pad journal bearings through parametric studies. The steady state performance characteristics of the bearing are represented by load capacity, stiffness coefficients and heat generation rate of the bearing. The geometrical parameters such as bearing clearances, preload of pads, etc. are varied and performance characteristics of the floating pad journal bearing are studied and presented. The dependence of stiffness coefficients on rotational speed of shaft is also analyzed.

  17. An alternative to conventional babbitt metal-lined generator pads

    Energy Technology Data Exchange (ETDEWEB)

    Puuska, H. [Imatra Hydroelectric Power Plant (Finland)

    1996-08-01

    The generator refurbishment of the Imatra Hydroelectric Power Plant Unit 1 in Finland is described. The generator work called for installation of a new cooling system for the generator thrust bearing. The considerations leading to the decision to replace the conventional babbitt metal-lined pads with elastic metal-plastic coated thrust bearing pads and the installation of the new pads are outlined in the article. Results of the trial run are summarized; the end temperature of the unit was more than 20C lower than for units equipped with conventional babbitted bearings.

  18. Exploring the use of iPads in Danish schools

    DEFF Research Database (Denmark)

    Khalid, Md. Saifuddin; Jurisic, Olivera; Kristensen, Henrik Stein

    2014-01-01

    Mobile devices, especially the integration and adoption of iPads in school classrooms, is gaining emphasis across the research and development forums of academic, policy, organizational, political, and public spheres. In April 2012, the Danish government announced that they would allocate DKK 500...... of integrating and adopting desktop computers and other educational technologies. However, there are some unique advantages that iPad and other mobile devices can enable through apps, readiness, etc. Policies and strategies should be adopted to combine training and maintenance along with ensuring access to iPads....

  19. Nonlinear Dynamics Analysis of Tilting Pad Journal Bearing-Rotor System

    Directory of Open Access Journals (Sweden)

    Jiayang Ying

    2011-01-01

    Full Text Available The nonlinear dynamics theory is increasingly applied in the dynamics analysis of tilting pad journal bearing-rotor system. However, extensive work on system dynamics done previously neglects the influence caused by the moment of inertia of the pad. In this paper, a comparison is made between the responses of the rotor in the bearings with and without pad inertia effect. Taking the Jeffcott rotor system as an example, the characteristics of bearing-rotor system, such as bifurcation diagram, cycle response, frequency spectrum, phase trajectories, and Poincaré maps, were attained within a certain rotation rate range. The pivotal oil-film force of tilting pad journal bearing was calculated by database method. The results directly demonstrate that considering the influence of the pad moment of inertia, system dynamics characteristics are found more complicated when rotor-bearing system works around natural frequency and system bifurcation is observed forward when rotor-bearing system works on high-speed range.

  20. Dryout power of a CANFLEX bundle string with raised bearing pads

    International Nuclear Information System (INIS)

    Leung, L.K.H.; Dimmick, G.R.; Bullock, D.E.; Inch, W.W.R.; Jun, J.S.; Suk, H.C.

    2001-01-01

    Dryout power data have been obtained with CANFLEX bundle strings equipped with raised bearing pads (1.7 mm and 1.8 mm height as compared to 1.4 mm in the current Mk-IV design) at Stern Laboratories. The experiment covered a wide range of steam-water flow conditions in three flow tubes simulating uncrept, and 3.3% and 5.1% crept profiles. The dryout power follows consistent parametric trends: it increases with increasing mass-flow rate, and decreases with increasing pressure, inlet-fluid temperature and channel creep. Local and boiling-length-average (BLA) critical-heat-flux (CHF) values were evaluated from the dryout-power measurements. The dryout power and BLA CHF values of the high bearing-pad bundles are higher than those of the low bearing-pad bundles at the same channel inlet flow conditions. On average, the dryout powers for bundles with 1.7 mm and 1.8 mm bearing pads are about 8% and 10%, respectively, higher than those for the bundle with 1.4 mm bearing pads. Compared to the 37-element bundle, an enhancement in dryout power is shown with CANFLEX bundles for all bearing-pad heights, at flow conditions of interest for reactor licensing. The average dryout power enhancement varies from 4% for the CANFLEX bundle with 1.4 mm bearing pads in the uncrept channel to 27% for the CANFLEX bundle with 1.8 mm bearing pads in the 5.1% crept channel. (author)

  1. Therapeutic effects of the smartphones and pads on hyperopia amblyopia of children

    Directory of Open Access Journals (Sweden)

    Ze-Hong Dong

    2017-11-01

    Full Text Available AIM: To evaluate the therapeutic effects of the fine sight training with the smartphones and pads on hyperopia amblyopia of children.METHODS: One hundred and twenty children(120 eyeswith hyperopia amblyopia were randomly divided into two groups in this prospective study. All the children in these two groups received the basic treatments of spectacle correction, penalization therapy and amblyopia trainings. The treatments of red-light blinking and grating as well as traditional fine sight training were used for the children in the control group. However, the smartphones and pads were applied instead of the traditional performances for the fine sight training in the experimental group. Best corrected visual acuity of every child was tested for every 3mo, to observe the time for the visual improvement and efficacy.RESULTS: In comparison with the control group, significant shorter time(80.54±30.87d, PPZ=-2.37, P=0.02.CONCLUSION: The fine sight training with the smartphones and pads can improve vison faster than traditional methods and decrease the time of therapy in children with hyperopia amblyopia, thus providing a new strategy for the treatment of hyperopia amblyopia.

  2. Effect of conditioner load on the polishing pad surface during chemical mechanical planarization process

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Min; Qin, Hong Yi; Hong, Seok Jun; Jeon, Sang Hyuk; Kulkarni, Atul; Kim, Tae Sun [Sungkyunkwan University, Suwon (Korea, Republic of)

    2016-12-15

    During the Chemical mechanical planarization (CMP), the pad conditioning process can affect the pad surface characteristics. Among many CMP process parameters, the improper applied load on the conditioner arm may have adverse effects on the polyurethane pad. In this work, we evaluated the pad surface properties under the various conditioner arm applied during pad conditioning process. The conditioning pads were evaluated for surface topography, surface roughness parameters such as Rt and Rvk and Material removal rate (MRR) and within-wafer non-uniformity after wafer polishing. We observed that, the pad asperities were collapsed in the direction of conditioner rotation and blocks the pad pores applied conditioner load. The Rvk value and MRR were founded to be in relation with 4 > 1 > 7 kgF conditioner load. Hence, this study shows that, 4 kgF applied load by conditioner is most suitable for the pad conditioning during CMP.

  3. 21 CFR 890.3790 - Cane, crutch, and walker tips and pads.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cane, crutch, and walker tips and pads. 890.3790 Section 890.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., crutch, and walker tips and pads. (a) Identification. Cane, crutch, and walker tips and pads are rubber...

  4. Heating Augmentation Due to Compression Pad Cavities on the Project Orion CEV Heat Shield

    Science.gov (United States)

    Hollis, Brian R.

    2009-01-01

    An experimental study has been conducted to assess the effects of compression pad cavities on the aeroheating environment of the Project Orion CEV heat-shield. Testing was conducted in Mach 6 and Mach 10 perfect-gas wind tunnels to obtain heating measurements in and around the compression pads cavities using global phosphor thermography. Data were obtained over a wide range of Reynolds numbers that produced laminar, transitional, and turbulent flow within and downstream of the cavities. The effects of cavity dimensions on boundary-layer transition and heating augmentation levels were studied. Correlations were developed for transition onset and for the average cavity-heating augmentation.

  5. A combination drift chamber/pad chamber for very high readout rates

    International Nuclear Information System (INIS)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W.; Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Arenton, M.; Conetti, S.; Cox, B.; Dukes, E.; Golovatyuk, V.; Hanlet, P.; McManus, A.; Nelson, K.; Recagni, M.; Segal, J.; Sun, J.; Ballagh, C.; Bingham, H.; Kaeding, T.; Lys, J.; Misawa, S.; Blankman, A.; Borodin, S.; Kononenko, W.; Newcomer, M.; Selove, W.; Trojak, T.; VanBerg, R.; Zhang, S.N.; Block, M.; Corti, G.; LeCompte, T.; Rosen, J.; Yao, T.; Boden, A.; Cline, D.; Ramachandran, S.; Rhoades, J.; Tokar, S.; Budagov, J.; Tsyganov, E.; Cao, Z.L.; He, M.; Wang, C.; Wei, C.; Zhang, N.; Chen, T.Y.; Yao, N.; Clark, K.; Jenkins, M.; Cooper, M.; Creti, P.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Fortney, L.; Kowald, W.; Haire, M.; Judd, D.; Turnbull, L.; Wagoner, D.; Lau, K.; Mo, G.; Trischuk, J.

    1991-11-01

    Six medium-sized (∼1 x 2 m 2 ) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers

  6. A combination drift chamber/pad chamber for very high readout rates

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W. (Fermi National Accelerator Lab., Batavia, IL (United States)); Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J. (Wisconsin Univ., Madison, WI (United States)); Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P. (Pavia Univ. (Italy) Istituto Nazionale di Fisica Nucleare, Rome (Italy)); Arenton, M.; Conetti, S.

    1991-11-01

    Six medium-sized ({approx}1 {times} 2 m{sup 2}) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers.

  7. Neurosurgical simulation by interactive computer graphics on iPad.

    Science.gov (United States)

    Maruyama, Keisuke; Kin, Taichi; Saito, Toki; Suematsu, Shinya; Gomyo, Miho; Noguchi, Akio; Nagane, Motoo; Shiokawa, Yoshiaki

    2014-11-01

    Presurgical simulation before complicated neurosurgery is a state-of-the-art technique, and its usefulness has recently become well known. However, simulation requires complex image processing, which hinders its widespread application. We explored handling the results of interactive computer graphics on the iPad tablet, which can easily be controlled anywhere. Data from preneurosurgical simulations from 12 patients (4 men, 8 women) who underwent complex brain surgery were loaded onto an iPad. First, DICOM data were loaded using Amira visualization software to create interactive computer graphics, and ParaView, another free visualization software package, was used to convert the results of the simulation to be loaded using the free iPad software KiwiViewer. The interactive computer graphics created prior to neurosurgery were successfully displayed and smoothly controlled on the iPad in all patients. The number of elements ranged from 3 to 13 (mean 7). The mean original data size was 233 MB, which was reduced to 10.4 MB (4.4% of original size) after image processing by ParaView. This was increased to 46.6 MB (19.9%) after decompression in KiwiViewer. Controlling the magnification, transfer, rotation, and selection of translucence in 10 levels of each element were smoothly and easily performed using one or two fingers. The requisite skill to smoothly control the iPad software was acquired within 1.8 trials on average in 12 medical students and 6 neurosurgical residents. Using an iPad to handle the result of preneurosurgical simulation was extremely useful because it could easily be handled anywhere.

  8. iPads in Inclusive Classrooms: Ecologies of Learning

    Science.gov (United States)

    Meyer, Bente

    2013-01-01

    This paper builds on data from a project where iPads were used in a lower secondary school in Denmark to support school development and inclusive learning environments. The paper explores how iPads enter into and work as part of an ecology of learning in five classes in lower secondary school. The paper argues that we should disengage approaches…

  9. iPad Use in Seventh Grade Math: Parent and Student Perceptions

    Science.gov (United States)

    Corbett, Robin

    2015-01-01

    The purpose of this qualitative research study was to compare student and parental perceptions of mobile technology use, specifically iPads, in seventh grade math classrooms and at home. How students and parents perceive the use of iPads within the seventh grade math classroom and how students and parents perceive the influence of iPad use at home…

  10. Barriers to the Integration and Adoption of iPads in Schools

    DEFF Research Database (Denmark)

    Khalid, Md. Saifuddin; Kilic, Gökce; Christoffersen, Jeanette

    2015-01-01

    iPad, with its Apple platform and interoperability-dependent material conditions, bring complex barriers in its adoption and integration in secondary education system as a learning tool. In the schools’ context, it is an emerging educational technology for its affordances supporting collaborative...... learning. This systematic literature review on the barriers to the integration of iPad in primary and secondary schools is based on 13 peer-reviewed and full-text articles. The paper discusses what are the challenges in using iPad as a learning tool in primary and secondary educational settings....... The identified barriers are discussed in three broad categories or stages of innovation process in an educational context: basic challenges with the tool, barriers to the integration of the iPad in a school setting, and barriers in the use of the iPad....

  11. Control and sensor techniques for PAD servo motor drive

    DEFF Research Database (Denmark)

    Zsurzsan, Tiberiu-Gabriel; Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    The Piezoelectric Actuator Drive (PAD) is a new type of electrical motor that employs piezoelectric multilayer actuators coupled with a form-fitted micro-mechanical gearing to generate rotary motion. The PAD is precise, having a positioning error of less than 2 arc-seconds. Its typical output...

  12. Simulating pad-electrodes with high-definition arrays in transcranial electric stimulation

    Science.gov (United States)

    Kempe, René; Huang, Yu; Parra, Lucas C.

    2014-04-01

    Objective. Research studies on transcranial electric stimulation, including direct current, often use a computational model to provide guidance on the placing of sponge-electrode pads. However, the expertise and computational resources needed for finite element modeling (FEM) make modeling impractical in a clinical setting. Our objective is to make the exploration of different electrode configurations accessible to practitioners. We provide an efficient tool to estimate current distributions for arbitrary pad configurations while obviating the need for complex simulation software. Approach. To efficiently estimate current distributions for arbitrary pad configurations we propose to simulate pads with an array of high-definition (HD) electrodes and use an efficient linear superposition to then quickly evaluate different electrode configurations. Main results. Numerical results on ten different pad configurations on a normal individual show that electric field intensity simulated with the sampled array deviates from the solutions with pads by only 5% and the locations of peak magnitude fields have a 94% overlap when using a dense array of 336 electrodes. Significance. Computationally intensive FEM modeling of the HD array needs to be performed only once, perhaps on a set of standard heads that can be made available to multiple users. The present results confirm that by using these models one can now quickly and accurately explore and select pad-electrode montages to match a particular clinical need.

  13. Clinical Results of Arthroscopic Repair of Isolated Longitudinal Tear of Medial Meniscus by Vertical Cruciate Double Mattress Sutures with Outside-in Technique

    Directory of Open Access Journals (Sweden)

    Seyied Hamid Barzgar

    2013-09-01

    Full Text Available Introduction : Meniscal tears are one of the most common injuries treated by arthroscopic techniques. Arthroscopic meniscal repair is an accepted way of treatment for meniscal tears. Different arthroscopic techniques for meniscal repair are: inside-out, outside-in and all inside. In the first 2 techniques, meniscus is repaired by sutures and in the later by suture or by commercial ready implants . The goal of current study is assessing clinical results of arthroscopic repair of longitudinal meniscal tears with vertical cruciate double mattress sutures by outside-in technique after 9 months.   Methods: In this case series study, in 13 patients having criteria for engaging the study with longitudinal isolated meniscus tear, arthroscopic meniscal repair was done with vertical cruciate double mattress sutures by outside-in technique and patients were followed for 9 months.   Results: Of 13 patients, there were 12 males (92.3% and one female (7.7% aged 15-38 (average 28.3 years. In follow up period, there was one case (7.7% of irritation by subcutaneous knot. There was not any failure of repair. Average Lysholm score increased from 55.23 to 91.23 after 9 months of follow up, which was statistically significant (p<0.001. At the end of follow up period, there was not any medial joint line tenderness of knee, giving way or significant effusion or pain.   Conclusion: This study shows that this technique has a good short term outcome with no failure and low complications but it is necessary to do more long term studies to prove it.

  14. A novel readout concept for multianode photomultiplier tubes with pad matrix anode layout

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Vladimir [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States)]. E-mail: Popov@jlab.org; Majewski, Stan [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States); Welch, Benjamin L. [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States)

    2006-11-01

    We have developed a new analog readout concept for multianode photomultiplier tubes with a pad matrix anode layout. This new readout technique is the result of a modification of a technique previously developed at the Detector Group of Jefferson Lab (V. Popov, US patent No: 6,747,263 B1) [V. Popov, S. Majewski, A.G. Weisenberger, Readout Electronics for Multianode Photomultiplier Tubes with Pad Matrix Anode Layout, Thomas Jefferson National Accelerator Facility, IEEE 2003 Medical Imaging Conference Record, November 2003]. The new analog readout circuit provides the same analog conversion of matrix 2-D output into X and Y projective output with a significant reduction of analog outputs. The old readout network consists of resistors' matrix and current collecting amplifiers, and it provides decoupling of each anode output into two directions (one to X and one to Y coordinates), but a decoupling function that is carried out independent of photomultiplier tube gains nonuniformity. A newly developed readout network (US patent pending) also consists of resistors' matrix and current collecting amplifiers, but the new matrix includes an additional dumping resistor that provides an excess current from anode pad grounding. As a result, we subtract an extra current of high-gain pads in order to move the pads gain to an absolute minimum value for a given photomultiplier tube. This gain equalization procedure reduces image distortion related to gain nonuniformity. The new readout technique was used in several new radiation imaging detectors designed in the Detector Group of Jefferson Lab. It shows a visible readout uniformity and linearity improvement. The test results of an initial evaluation of this readout that is applied for data readout of four H8500 Hamamtsu PSPMT are presented.

  15. Pad A treatability study long-range project plan

    International Nuclear Information System (INIS)

    Mousseau, J.D.

    1991-06-01

    This plan addresses the work to be accomplished by the Pad A Treatability Study Project. The purpose of this project is to investigate potential treatment and separation technologies, identify the best technologies, and to demonstrate by both lab- and pilot-scale demonstration, the most applicable remedial technologies for treating plutonium-contaminated salts at the Pad A site located at the Subsurface Disposal Area (SDA) at the Radioactive Waste Management Complex (RWMC) a the Idaho National Engineering Laboratory (INEL). The conduct of this project will be supported by other DOE laboratories, universities, and private industries, who will provide support for near-term demonstrations of treatment and separation technologies. The purpose of this long-range planning document is to present the detailed plan for the implementation of the Pad A Treatability Study Project

  16. Kager's fat pad inflammation associated with HIV infection and AIDS: MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Godoy-Santos, Alexandre Leme; Fernandes, Tulio Diniz; Camanho, Gilberto Luis [University of Sao Paulo, Department of Orthopedic Surgery, Sao Paulo, SP (Brazil); Bordalo-Rodrigues, Marcelo; Rosemberg, Laercio [University of Sao Paulo, Department of Radiology, Sao Paulo (Brazil); Lei Munhoz Lima, Ana Lucia [University of Sao Paulo, Department of Infectious Disease, Sao Paulo (Brazil); Maffulli, Nicola [Mile End Hospital, Centre for Sports and Exercise Medicine Barts and The London School of Medicine and Dentistry, London (United Kingdom)

    2014-09-15

    To describe magnetic resonance imaging (MRI) features of Kager's fat pad inflammation in HIV-positive patients with lipodystrophy due to protease inhibitor treatment and posterior ankle pain. A case-control, cross-sectional study; group 1 included 14 HIV-positive patients using protease inhibitors, presenting lipodystrophy syndrome and having posterior ankle pain; group 2 (CGHIV-) included 112 HIV-negative patients without lipodystrophy syndrome who were being evaluated for posterior ankle pain; group 3 (CGHIV + 1) included 23 HIV-positive patients not using a protease inhibitor, without lipodystrophy syndrome and with posterior ankle pain; group 4 (CGHIV + 2) comprised 18 HIV-positive patients who were being treated with a protease inhibitor and had lipodystrophy syndrome but did not have posterior ankle pain. Images were evaluated for the presence of edema by two radiologists who were blinded to clinical features. Fisher's exact test was used to evaluate differences among the groups. Interobserver variation was tested using Cohen's kappa (κ) statistic. The presence of edema within Kager's fat pad was strongly associated with symptoms in HIV-positive patients who had lipodystrophy (p ≤ 0.0001). Concordance between observers was excellent (κ > 0.9). MRI findings of Kager's fat pad inflammation related to HIV/AIDS is a source of symptoms in HIV patients with posterior ankle pain using protease inhibitors and having lipodystrophy syndrome. (orig.)

  17. Assessing the iPad as a tool for low-vision rehabilitation.

    Science.gov (United States)

    Mednick, Zale; Jaidka, Atul; Nesdole, Robert; Bona, Mark

    2017-02-01

    It has been demonstrated consistently that patients with poor vision have a reduced quality of life and functional status and higher rates of psychologic distress. This study aims to assess whether the iPad has potential as a visual aid in patients with low vision. Qualitative study with key-informant interviews. Patients who identified as having impaired vision were recruited from a low vision ophthalmology clinic. Patients participated in a 4-session iPad training course. The goal of the course was to teach patients with low vision how to operate an iPad, with a particular emphasis on how to optimize iPad settings and accessibility features in response to some of the challenges faced by patients with low vision. Three interviews were conducted with each participant: before the course, immediately after the course, and 3 months after the course. The purpose of the interviews was to gain an understanding of their experience with low vision and to assess if and how the iPad had influenced this experience. A grounded theory qualitative approach was used for analysis. Six patients took part in the study and were divided into 2 separate courses to minimize course size. Participants had favorable views regarding the course. Five of the 6 participants were using the iPad on a daily basis 3 months after the course. Thematic analysis revealed that use of the iPad led to both a heightened sense of independence and improved social connectivity. It is theorized that use of the iPad as a low-vision aid may enhance a patient's sense of self-worth. With proper training, the iPad has the potential to be a valuable tool for low-vision patients. Its features help patients to gain independence and to stay connected within their social circles. Further research with a larger patient population and quantifiable endpoints should focus on these themes. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  18. Ultrasound appearance of knuckle pads

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Ben, R. [Univ. of Alabama, Birmingham (United States). Dept. of Diagnostic Radiology; Dehghanpisheh, K.; Chatham, W.W.; Alarcon, G.S. [Univ. of Alabama, Birmingham (United States). Dept. of Medicine; Lee, D.H.; Oakes, J. [Univ. of Alabama, Birmingham (United States). Dept. of Surgery

    2006-11-15

    We describe the ultrasound appearance of knuckle pads. Retrospective analysis of imaging in a series of five patients initially referred for evaluation of periarticular soft-tissue swelling of the hands involving the dorsum of the PIP and MP joints. Two patients had associated Dupuytren's contractures. Ultrasound and radiographs of the hands in all patients were reviewed and correlated with clinical history and physical exams. Radiographs in four patients demonstrated dorsal soft-tissue thickening. Ultrasound exams showed increased dorsal subcutaneous thickening, with either diffuse or focal hypoechoic areas corresponding to the areas of soft-tissue fullness identified on physical exam. No erosions or synovial proliferation were identified either by radiographs or ultrasound of the underlying joints. Knuckle pads can sometimes be difficult to distinguish from synovitis on physical examination. Musculoskeletal ultrasound can quickly identify these superficial lesions and exclude underlying synovial proliferation.

  19. Rice pads. Devices to improve the effect of fat suppression of CHESS images

    International Nuclear Information System (INIS)

    Moriya, Susumu; Yokobayashi, Tsuneo; Miki, Yukio

    2013-01-01

    The chemical shift selective (CHESS) method is often used for fat suppression in magnetic resonance imaging. CHESS has several advantages, including versatility, quick imaging, and applicability to contrast examinations. One disadvantage of CHESS is the lingering fat signal generated as a result of nonuniformity of the static magnetic field. To overcome this drawback, some researchers have used pads made with polished rice (rice pads), a simple method in which rice pads are placed outside the area to be imaged. We describe ways to improve CHESS images, characteristics of the rice pad, its application to imaging, and methods of placing the pad. (author)

  20. Bit-padding information guided channel hopping

    KAUST Repository

    Yang, Yuli

    2011-02-01

    In the context of multiple-input multiple-output (MIMO) communications, we propose a bit-padding information guided channel hopping (BP-IGCH) scheme which breaks the limitation that the number of transmit antennas has to be a power of two based on the IGCH concept. The proposed scheme prescribes different bit-lengths to be mapped onto the indices of the transmit antennas and then uses padding technique to avoid error propagation. Numerical results and comparisons, on both the capacity and the bit error rate performances, are provided and show the advantage of the proposed scheme. The BP-IGCH scheme not only offers lower complexity to realize the design flexibility, but also achieves better performance. © 2011 IEEE.

  1. iPads: Improving Numeracy Learning in the Early Years

    Science.gov (United States)

    Spencer, Peta

    2013-01-01

    The concept of mobile technologies is now an emergency theme in educational research, yet the playing of these edutainment applications and their impact on early childhood learning needs to be fully explored. This study highlights current research and explores how iPads improve student learning. It also examines how the introduction of iPads,…

  2. iPad Use and Student Engagement in the Classroom

    Science.gov (United States)

    Mango, Oraib

    2015-01-01

    iPads and handheld digital devices have been securing their place in educational institutions surrounded by debates between advocates and skeptics. In light of not enough evidence supporting the use of iPads in education, this study examined the ways that college students in two foreign language classrooms perceived the influence of the use of…

  3. Tilting-Pad Guide Bearing in Large Hydro-unit

    Directory of Open Access Journals (Sweden)

    Li-Feng Ma

    2000-01-01

    Full Text Available A new numerical method is proposed for predicting the nonlinearity of tilting-pad guide bearing oilfilm force in the rotor-bearing system in a large hydro-unit. Nonlinear displacement and velocity of the journal center, as well as nonlinear tilting angles and angular velocities of the pads in non-stationary Reynolds equation are taken into account. This method is also suited for other small rotor-bearing system. As an example, the response due to a momentarily created unbalance is Calculated. The nonlinear motion patterns of the pad and journal whirling orbit are obtained. Finally, the nonlinear orbit is compared to the linear one that could be calculated from linear stiffness and damping coefficients. It is shown that there are important differences between those two orbits and that the nonlinear simulation is more accurate.

  4. Nappy pad urine samples for investigation and treatment of UTI in young children: the 'DUTY' prospective diagnostic cohort study.

    Science.gov (United States)

    Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-07-01

    The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.

  5. ImagePAD, a novel counting application for the Apple iPad, used to quantify axons in the mouse optic nerve.

    Science.gov (United States)

    Templeton, Justin P; Struebing, Felix L; Lemmon, Andrew; Geisert, Eldon E

    2014-11-01

    The present article introduces a new and easy to use counting application for the Apple iPad. The application "ImagePAD" takes advantage of the advanced user interface features offered by the Apple iOS platform, simplifying the rather tedious task of quantifying features in anatomical studies. For example, the image under analysis can be easily panned and zoomed using iOS-supported multi-touch gestures without losing the spatial context of the counting task, which is extremely important for ensuring count accuracy. This application allows one to quantify up to 5 different types of objects in a single field and output the data in a tab-delimited format for subsequent analysis. We describe two examples of the use of the application: quantifying axons in the optic nerve of the C57BL/6J mouse and determining the percentage of cells labeled with NeuN or ChAT in the retinal ganglion cell layer. For the optic nerve, contiguous images at 60× magnification were taken and transferred onto an Apple iPad. Axons were counted by tapping on the touch-sensitive screen using ImagePAD. Nine optic nerves were sampled and the number of axons in the nerves ranged from 38,872 axons to 50,196 axons with an average of 44,846 axons per nerve (SD = 3980 axons). Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. iPhone and iPad apps for absolute beginners

    CERN Document Server

    Lewis, Rory

    2013-01-01

    So how do you build an application for the iPhone and iPad? Don't you need to spend years learning complicated programming languages? What about Objective-C and Cocoa touch? The answer is that you don't need to know any of those things! Anybody can start building simple apps for the iPhone and iPad, and this book will show you how. This update of an Apress bestseller walks you through creating your first app, using plain English and practical examples using the iOS 6 software development platform and more. It cuts through the fog of jargon and misinformation that surrounds iPhone and iPad app

  7. iBooks and ePeriodicals on the iPad

    CERN Document Server

    Biersdorfer, J

    2010-01-01

    This Mini Missing Manual takes you down the virtual rows of Apple's iBookstore, to help you find, buy, and download books and subscribe to magazine and newspapers on your iPad. You'll learn now to navigate your books and periodicals and sync them back to iTunes to swap them on and off your iPad to free up storage space. In addition, you'll find out where to get free books in the iBookstore, and where you can shop for iPad-compatible books, both free and for-pay, outside of Apple's domain. Finally, you'll learn the fine art of eBook navigation, including how to change a book's font and font

  8. Pad-mode-induced instantaneous mode instability for simple models of brake systems

    Science.gov (United States)

    Oberst, S.; Lai, J. C. S.

    2015-10-01

    Automotive disc brake squeal is fugitive, transient and remains difficult to predict. In particular, instantaneous mode squeal observed experimentally does not seem to be associated with mode coupling and its mechanism is not clear. The effects of contact pressures, friction coefficients as well as material properties (pressure and temperature dependency and anisotropy) for brake squeal propensity have not been systematically explored. By analysing a finite element model of an isotropic pad sliding on a plate similar to that of a previously reported experimental study, pad modes have been identified and found to be stable using conventional complex eigenvalue analysis. However, by subjecting the model to contact pressure harmonic excitation for a range of pressures and friction coefficients, a forced response analysis reveals that the dissipated energy for pad modes is negative and becomes more negative with increasing contact pressures and friction coefficients, indicating the potential for instabilities. The frequency of the pad mode in the sliding direction is within the range of squeal frequencies observed experimentally. Nonlinear time series analysis of the vibration velocity also confirms the evolution of instabilities induced by pad modes as the friction coefficient increases. By extending this analysis to a more realistic but simple brake model in the form of a pad-on-disc system, in-plane pad-modes, which a complex eigenvalue analysis predicts to be stable, have also been identified by negative dissipated energy for both isotropic and anisotropic pad material properties. The influence of contact pressures on potential instabilities has been found to be more dominant than changes in material properties owing to changes in pressure or temperature. Results here suggest that instantaneous mode squeal is likely caused by in-plane pad-mode instabilities.

  9. Metacarpophalangeal joint synovial pad fibrotic proliferation in 63 horses

    International Nuclear Information System (INIS)

    Dabareiner, R.M.; White, N.A.; Sullins, K.E.

    1996-01-01

    Medical records, radiographs, and sonograms of 63 horses with metacarpophalangeal joint synovial pad proliferation were examined retrospectively. AR horses had lameness, joint effusion, or both signs associated with one or both metacarpophalangeal joints. Bony remodeling and concavity of the distodorsal aspect of the third metacarpal bone (Mc3) just proximal to the metacarpal condyles was identified by radiography in 71 joints (93%); 24 joints (32%) had radiographic evidence of a chip fracture located at the proximal dorsal aspect of the proximal phalanx. Fifty-four joints (71%) were examined by ultrasound. The mean +- SD sagittal thickness of the synovial pad was 11.3 +- 2.8 mm. Seventy-nine percent of the horses had single joint involvement with equal distribution between the right and left forelimbs. Sixty-eight joints in 55 horses were treated by arthroscopic surgery. Sixty joints (88%) had debridement of chondral or osteochondral fragmentation from the dorsal surface of Mc3 beneath the synovial pad and 30 joints (44%) had a bone chip fracture removed from the medial or lateral proximal dorsal eminence of the proximal phalanx. Complete or partial excision of both medial and lateral synovial pads was completed in 42 joints. Only the medial synovial pad was excised or trimmed in 21 joints, and 5 joints had only the lateral pad removed. Eight joints in eight horses were treated by stall rest, administration of intra-articular medication and systemic nonsteroidal anti-inflammatory drugs. Follow-up information was obtained for 50 horses treated surgically and for eight horses treated medically. Forty-three (86%) that had surgery returned to racing; 34 (68%) raced at an equivalent or better level than before surgery. Three (38%) of the medically treated horses returned to racing; only one horse raced better than the preinjury level. Horses that returned to racing at a similar or equal level of performance were significantly younger in age than horses returning at a

  10. An Evaluation of the Compressive Properties of Helmet Pads Pre- and Post-Shock Wave Overpressure Exposure

    Science.gov (United States)

    2015-08-14

    Regulation, Chapter IX. For Unclassified/Limited Distribution Documents: Destroy by any method that prevents disclosure of contents or reconstruction of...OVERPRESSURE WOUNDS AND INJURIES IMPACT STATIC TESTS PADS(CUSHIONS) TEST AND EVALUATION TRAUMA ...simplified version of the Facial and Ocular Countermeasure for Safety (FOCUS) headform. The FOCUS headform is commercially available through Humanetics

  11. A novel nonlinear nano-scale wear law for metallic brake pads.

    Science.gov (United States)

    Patil, Sandeep P; Chilakamarri, Sri Harsha; Markert, Bernd

    2018-05-03

    In the present work, molecular dynamics simulations were carried out to investigate the temperature distribution as well as the fundamental friction characteristics such as the coefficient of friction and wear in a disc-pad braking system. A wide range of constant velocity loadings was applied on metallic brake pads made of aluminium, copper and iron with different rotating speeds of a diamond-like carbon brake disc. The average temperature of Newtonian atoms and the coefficient of friction of the brake pad were investigated. The resulting relationship of the average temperature with the speed of the disc as well as the applied loading velocity can be described by power laws. The quantitative description of the volume lost from the brake pads was investigated, and it was found that the volume lost increases linearly with the sliding distance. Our results show that Archard's linear wear law is not applicable to a wide range of normal loads, e.g., in cases of low normal load where the wear rate was increased considerably and in cases of high load where there was a possibility of severe wear. In this work, a new formula for the brake pad wear in a disc brake assembly is proposed, which displays a power law relationship between the lost volume of the metallic brake pads per unit sliding distance and the applied normal load with an exponent of 0.62 ± 0.02. This work provides new insights into the fundamental understanding of the wear mechanism at the nano-scale leading to a new bottom-up wear law for metallic brake pads.

  12. IntelligentPad for exchanging and reusing nuclear reaction data information as shared resources

    International Nuclear Information System (INIS)

    Chiba, Masaki

    1996-01-01

    As an application of the IntelligentPad system, the NRDF database system is redesigned and developed. In the system, every component of the user interface is represented by reactive media objects called Pad. The exploitation of the IntelligentPad architecture in developing the system enhances the usability and reusability of the tools developed. Several pads specially designed for the NRDF database system are shown together with the examples of how to use them. (author)

  13. Steady state characteristics of a tilting pad journal bearing with controllable lubrication: Comparison between theoretical and experimental results

    DEFF Research Database (Denmark)

    Cerda Varela, Alejandro Javier; Nielsen, Bo Bjerregaard; Santos, Ilmar

    2013-01-01

    direction. The modification of the injection pressure enables to modify the bearing static and dynamic properties according to the operational needs. The results presented are obtained using a theoretical model, which considers all the effects that determine the bearing behavior (controllable......This paper is aimed at presenting results regarding the static and thermal behavior of a tilting-pad journal bearing operating under controllable regime. The bearing is rendered controllable by injecting high pressure oil into the clearance using holes drilled across the bearing pads in the radial...... elastothermohydrodynamic lubrication regime), as well as using a test rig designed and built to this effect. The comparison between experimental and theoretical results provides solid ground to determine the accuracy of the available model for the the prediction of the steady-state behavior of the tilting-pad bearing...

  14. Self-drying: a gecko's innate ability to remove water from wet toe pads.

    Directory of Open Access Journals (Sweden)

    Alyssa Y Stark

    Full Text Available When the adhesive toe pads of geckos become wet, they become ineffective in enabling geckos to stick to substrates. This result is puzzling given that many species of gecko are endemic to tropical environments where water covered surfaces are ubiquitous. We hypothesized that geckos can recover adhesive capabilities following exposure of their toe pads to water by walking on a dry surface, similar to the active self-cleaning of dirt particles. We measured the time it took to recover maximum shear adhesion after toe pads had become wet in two groups, those that were allowed to actively walk and those that were not. Keeping in mind the importance of substrate wettability to adhesion on wet surfaces, we also tested geckos on hydrophilic glass and an intermediately wetting substrate (polymethylmethacrylate; PMMA. We found that time to maximum shear adhesion recovery did not differ in the walking groups based on substrate wettability (22.7±5.1 min on glass and 15.4±0.3 min on PMMA but did have a significant effect in the non-walking groups (54.3±3.9 min on glass and 27.8±2.5 min on PMMA. Overall, we found that by actively walking, geckos were able to self-dry their wet toe pads and regain maximum shear adhesion significantly faster than those that did not walk. Our results highlight a unexpected property of the gecko adhesive system, the ability to actively self-dry and recover adhesive performance after being rendered dysfunctional by water.

  15. Chemical mechanical planarization of amorphous Ge2Sb2Te5 with a soft pad

    International Nuclear Information System (INIS)

    He Aodong; Liu Bo; Song Zhitang; Lü Yegang; Li Juntao; Liu Weili; Feng Songlin; Wu Guanping

    2013-01-01

    Chemical mechanical planarization (CMP) of amorphous Ge 2 Sb 2 Te 5 (a-GST) is investigated using two typical soft pads (politex REG and AT) in acidic slurry. After CMP, it is found that the removal rate (RR) of a-GST increases with an increase of runs number for both pads. However, it achieves the higher RR and better surface quality of a-GST for an AT pad. The in-situ sheet resistance (R s ) measure shows the higher R s of a-GST polishing can be gained after CMP using both pads and the high R s is beneficial to lower the reset current for the PCM cells. In order to find the root cause of the different RR of a-GST polishing with different pads, the surface morphology and characteristics of both new and used pads are analyzed, it shows that the AT pad has smaller porosity size and more pore counts than that of the REG pad, and thus the AT pad can transport more fresh slurry to the reaction interface between the pad and a-GST, which results in the high RR of a-GST due to enhanced chemical reaction. (semiconductor technology)

  16. Dynamic Coefficients of a Tilting Pad With Active Lubrication: Comparison Between Theoretical and Experimental Results

    DEFF Research Database (Denmark)

    Cerda Varela, Alejandro Javier; Santos, Ilmar

    2015-01-01

    experimental results from the literature for industrial grade passive tilting pad bearings. This initial validation is followed by a comparison with experimental identification results obtained from a test rig featuring the active bearing design. Good overall agreement is observed in both configurations...

  17. Fast micro Hall effect measurements on small pads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Petersen, Dirch Hjorth; Nielsen, Peter F.

    2011-01-01

    Sheet resistance, carrier mobility, and sheet carrier density are important parameters in semiconductor production, and it is therefore important to be able to rapidly and accurately measure these parameters even on small samples or pads. The interpretation of four-point probe measurements on small...... pads is non-trivial. In this paper we discuss how conformal mapping can be used to evaluate theoretically expected measurement values on small pads. Theoretical values calculated from analytical mappings of simple geometries are compared to the values found from the numerical conformal mapping...... of a square onto the infinite half-plane, where well-established solutions are known. Hall effect measurements are performed to show, experimentally, that it is possible to measure Hall mobility in less than one minute on squares as small as 7070 lm2 with a deviation of 66.5% on a 1r level from accurate...

  18. Exposure-rate calibration using large-area calibration pads

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-09-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. A set of large-area, radioelement-enriched concrete pads was constructed by the DOE in 1978 at the Walker Field Airport in Grand Junction for use as calibration standards for airborne gamma-ray spectrometer systems. The use of these pads was investigated by the TMC as potential calibration standards for portable scintillometers employed in measuring gamma-ray exposure rates at Uranium Mill Tailings Remedial Action (UMTRA) project sites. Data acquired on the pads using a pressurized ionization chamber (PIC) and three scintillometers are presented as an illustration of an instrumental calibration. Conclusions and recommended calibration procedures are discussed, based on the results of these data

  19. iPad in the Enterprise Developing and Deploying Business Applications

    CERN Document Server

    Clevenger, Nathan

    2011-01-01

    Discover how to plan, design, develop, and deploy iPad apps for the enterprise Having taken the enterprise by storm, iPads are now in the hands of workers in virtually every level of companies in almost every industry. But using iPad apps in the enterprise is more complex than simply clicking an icon from the App Store. It presents unique challenges around software development, system integration, information security, application deployment, and device management. That's where this book comes in. iPhone Life Enterprise Editor and veteran mobile consultant Nathan Clevenger presents a guide for

  20. Arachnids secrete a fluid over their adhesive pads.

    Directory of Open Access Journals (Sweden)

    Anne M Peattie

    Full Text Available BACKGROUND: Many arachnids possess adhesive pads on their feet that help them climb smooth surfaces and capture prey. Spider and gecko adhesives have converged on a branched, hairy structure, which theoretically allows them to adhere solely by dry (solid-solid intermolecular interactions. Indeed, the consensus in the literature is that spiders and their smooth-padded relatives, the solifugids, adhere without the aid of a secretion. METHODOLOGY AND PRINCIPAL FINDINGS: We investigated the adhesive contact zone of living spiders, solifugids and mites using interference reflection microscopy, which allows the detection of thin liquid films. Like insects, all the arachnids we studied left behind hydrophobic fluid footprints on glass (mean refractive index: 1.48-1.50; contact angle: 3.7-11.2°. Fluid was not always secreted continuously, suggesting that pads can function in both wet and dry modes. We measured the attachment forces of single adhesive setae from tarantulas (Grammostola rosea by attaching them to a bending beam with a known spring constant and filming the resulting deflection. Individual spider setae showed a lower static friction at rest (26%±2.8 SE of the peak friction than single gecko setae (Thecadactylus rapicauda; 96%±1.7 SE. This may be explained by the fact that spider setae continued to release fluid after isolation from the animal, lubricating the contact zone. SIGNIFICANCE: This finding implies that tarsal secretions occur within all major groups of terrestrial arthropods with adhesive pads. The presence of liquid in an adhesive contact zone has important consequences for attachment performance, improving adhesion to rough surfaces and introducing rate-dependent effects. Our results leave geckos and anoles as the only known representatives of truly dry adhesive pads in nature. Engineers seeking biological inspiration for synthetic adhesives should consider whether model species with fluid secretions are appropriate to their

  1. The effect of time in use on the display performance of the iPad.

    Science.gov (United States)

    Caffery, Liam J; Manthey, Kenneth L; Sim, Lawrence H

    2016-07-01

    The aim of this study was to evaluate changes to the luminance, luminance uniformity and conformance to the digital imaging and communication in medicine greyscale standard display function (GSDF) as a function of time in use for the iPad. Luminance measurements of the American Association of Physicists in Medicine (AAPM) Group 18 task group (TG18) luminance uniformity and luminance test patterns (TG18-UNL and TG18-LN8) were performed using a calibrated near-range luminance meter. Nine sets of measurements were taken, where the time in use of the iPad ranged from 0 to 2500 h. The maximum luminance (Lmax) of the display decreased (367-338 cdm(-2)) as a function of time. The minimum luminance remained constant. The maximum non-uniformity coefficient was 11%. Luminance uniformity decreased slightly as a function of time in use. The conformance of the iPad deviated from the GSDF curve at commencement of use. Deviation did not increase as a function of time in use. This study has demonstrated that the iPad display exhibits luminance degradation typical of liquid crystal displays. The Lmax of the iPad fell below the American College of Radiology-AAPM-Society of Imaging Informatics in Medicine recommendations for primary displays (>350 cdm(-2)) at approximately 1000 h in use. The Lmax recommendation for secondary displays (>250 cdm(-2)) was exceeded during the entire study. The maximum non-uniformity coefficient did not exceed the recommendations for either primary or secondary displays. The deviation from the GSDF exceeded the recommendations of the TG18 for use as either a primary or secondary display. The brightness, uniformity and contrast response are reasonably stable over the useful lifetime of the device; however, the device fails to meet the contrast response standard for either a primary or secondary display.

  2. Friction and Braking Application of Unhazardous Palm Slag Brake Pad Composite

    Science.gov (United States)

    Khoni, Norizzahthul Ainaa Abdul; Ruzaidi Ghazali, Che Mohd; Bakri Abdullah, Mohd Mustafa Al

    2018-03-01

    This paper reveals new alternative friction materials for brake pads. Palm slag was studied as new friction materials in brake pads but its much harder made it difficult to be applied. As a way to reduce the hardness, tire dust was including as purpose on stabilizing the hardness of brake pads. The palm slag was sieves to get desired size that is 150 μm, 300 μm and 600 μm. The percentage weight of materials used are 20% graphite, 20% aluminium oxide, 20% steel fiber, 20% polyester resin and another 40% are varied between tire dust and palm slag. All of materials were blend and compress by using hot pressed machine. The composites properties that were examined are density, porosity, hardness, compressive strength, microstructure analysis and wear rate. The composition of 30% palm slag, 10% tire dust and larger size of filler give better result of mechanical properties and less wear rate of brake pads composites. Then, palm slag can be used in producing of non asbestos brake pads.

  3. Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring.

    Science.gov (United States)

    Sartiano, Demetrio; Sales, Salvador

    2017-12-13

    The aim of this paper is to report the design of a low-cost plastic optical fiber (POF) pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm) and a silicon light sensor. The Super ESKA ® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2-5 s (0.2-0.5 Hz). The sensor has a resolution of force applied on a single point of 2.2-4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.

  4. Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring

    Directory of Open Access Journals (Sweden)

    Demetrio Sartiano

    2017-12-01

    Full Text Available The aim of this paper is to report the design of a low-cost plastic optical fiber (POF pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm and a silicon light sensor. The Super ESKA® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2–5 s (0.2–0.5 Hz. The sensor has a resolution of force applied on a single point of 2.2–4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.

  5. Implementation Factors and Faculty Perceptions of Electronic Textbooks on the iPad

    Science.gov (United States)

    Rogers-Estable, Michelle Dawn

    2018-01-01

    A federally managed university in the United Arab Emirates implemented a one-to-one iPad program. In an effort to increase access to interactive digital learning resources on the iPads, they next transitioned from paperbased textbooks (pTexts) to electronic textbooks (eTexts) on the iPad for all course delivery formats. The goal of this study was…

  6. Een jaar later, onderzoek naar de implementatie van de iPad bij het Leeuwarder Lyceum : Een vervolgonderzoek naar het iPad-gebruik onder leerlingen en leraren van het Leeuwarder Lyceum

    NARCIS (Netherlands)

    Stephanie Nijssen; Klaas Jan Huizing

    2013-01-01

    In september 2012 is de iPad geïmplementeerd in het onderwijs van het Leeuwarder Lyceum. Sowijs onderzocht tijdens de implementatie welke verwachtingen leerlingen en leraren hadden van de iPad. Nu, een jaar later, hebben we opnieuw onderzoek gedaan onder leerlingen en leraren naar het iPad-gebruik.

  7. Quantum One-Time Pad in the Presence of an Eavesdropper

    Science.gov (United States)

    Brandão, Fernando G. S. L.; Oppenheim, Jonathan

    2012-01-01

    A classical one-time pad allows two parties to send private messages over a public classical channel—an eavesdropper who intercepts the communication learns nothing about the message. A quantum one-time pad is a shared quantum state which allows two parties to send private messages or private quantum states over a public quantum channel. If the eavesdropper intercepts the quantum communication she learns nothing about the message. In the classical case, a one-time pad can be created using shared and partially private correlations. Here we consider the quantum case in the presence of an eavesdropper, and find the single-letter formula for the rate at which the two parties can send messages using a general quantum state as a quantum one-time pad. Surprisingly, the formula coincides with the distillable entanglement assisted by a symmetric channel, an important quantity in quantum information theory, but which lacked a clear operational meaning.

  8. Contact statuses between functionally graded brake disk and pure pad disk

    International Nuclear Information System (INIS)

    Shahzamanian, M.M.; Sahari, B.B.; Bayat, M.; Mustapha, F.; Ismarrubie, Z.N.; Shahrjerdi, A.

    2009-01-01

    Full text: The contact statuses between functionally graded (FG) brake disks and pure pad disk are investigated by using finite element method (FEM). Two types of variation is considered for FG brake disk, the variation of materials are considered change in radial and thickness direction of disk. The material properties of these two types of FG brake disks are assumed to be represented by power-law distributions in the radius and thickness direction. The results are obtained and then compared. For the radial FG brake disk, the inner and outer surfaces are considered metal and ceramic respectively, and friction coefficient between metal surface and ceramic surface of FG brake dick with pad are considered 1.4 and 0.75 respectively. For the thickness FG brake disk the contact surface with pure pad brake disk is ceramic and the free surface is metal and friction coefficient between ceramic (contact) surface and pure pad brake disk is considered 0.75. In both types of FG brake disks the Coulomb contact friction is applied. Mechanical response of FG brake disks are compared and verified with the known results in the literatures. Three types of contact statuses are introduced as Sticking, Contact and Near Contact. The contact status between pad and disk for different values for pad thickness, grading index,n , and percentage of friction coefficient (λ) is shown. It can be seen that for all values of percentage of friction coefficient,λ , and grading indices, n, by increasing the thickness of pad cause the contact status changes from sticking to contact and then to near contact. (author)

  9. Making Data Mobile: The Hubble Deep Field Academy iPad app

    Science.gov (United States)

    Eisenhamer, Bonnie; Cordes, K.; Davis, S.; Eisenhamer, J.

    2013-01-01

    Many school districts are purchasing iPads for educators and students to use as learning tools in the classroom. Educators often prefer these devices to desktop and laptop computers because they offer portability and an intuitive design, while having a larger screen size when compared to smart phones. As a result, we began investigating the potential of adapting online activities for use on Apple’s iPad to enhance the dissemination and usage of these activities in instructional settings while continuing to meet educators’ needs. As a pilot effort, we are developing an iPad app for the “Hubble Deep Field Academy” - an activity that is currently available online and commonly used by middle school educators. The Hubble Deep Field Academy app features the HDF-North image while centering on the theme of how scientists use light to explore and study the universe. It also includes features such as embedded links to vocabulary, images and videos, teacher background materials, and readings about Hubble’s other deep field surveys. It is our goal is to impact students’ engagement in STEM-related activities, while enhancing educators’ usage of NASA data via new and innovative mediums. We also hope to develop and share lessons learned with the E/PO community that can be used to support similar projects. We plan to test the Hubble Deep Field Academy app during the school year to determine if this new activity format is beneficial to the education community.

  10. The effects of porosity in friction performance of brake pad using waste tire dust

    Directory of Open Access Journals (Sweden)

    İbrahim Mutlu

    2015-10-01

    Full Text Available Abstract This research is focused on the effect of porosity on the friction-wear properties of automotive brake pads. Waste Tire Dust (WTD was used as a new friction material in brake pads. Newly formulated brake pad materials with five different components have been produced by conventional techniques. In the experimental studies, the change of the friction coefficient, the temperature of the friction surface, the specific wear rate, and the hardness, density and porosity were measured. In addition, the micro-structural characterizations of brake pads are determined using Scanning Electron Microscopy (SEM. The mean coefficient of friction, porosity and specific wear are increased due to a WTD rate increases, on the other hand, hardness and density are decreased. As a result, WTD can be considered as an alternative to revalorize this kind of waste products in the brake pads and the amount of porosity of the brake pad affected the friction coefficient and wear behavior of the pad.

  11. Dew point effect of cooled hydrogel pads on human stratum corneum biosurface.

    Science.gov (United States)

    Xhauflaire-Uhoda, Emmanuelle; Paquet, Philippe; Piérard, Gérald E

    2008-01-01

    Cooled hydrogel pads are used to prevent overheating effects of laser therapy. They do not induce cold injuries to the skin, but their more subtle physiological effects have not been thoroughly studied. To describe the changes in transepidermal water loss and electrometric properties of the skin surface following application of cooled hydrogel pads. Measurements were performed on normal forearm skin of 27 healthy volunteers and on freshly excised skin from abdominoplasty. LaserAid hydrogel pads cooled to 4 degrees C were placed for 15 min on the forearm skin. Measurements of transepidermal water loss (TEWL) and electrometric properties (Corneometer, Nova DPM 900) were performed before application and after removal of the cooled pads. A consistent increase in corneometer units, dermal phase meter (DPM) values and TEWL were recorded at removal of the cooled hydrogel pads. Both the in vivo and in vitro assessments brought similar information. The similar changes disclosed in vitro and in vivo suggest that a common physical process is operating in these conditions. The observed phenomenon is opposite to the predicted events given by the Arrhenius law probably because of the combination of cooling and occlusion by the pads. A dew point effect (air temperature at which relative humidity is maximal) is likely involved in the moisture content of the stratum corneum. Thus, the biological impact of using cooling hydrogel pads during laser therapy is different from the effect of a cryogenic spray cooling procedure. The better preservation of the water balance in the stratum corneum by the cooled hydrogel pads could have a beneficial esthetic effect on laser treated areas. (c) 2008 S. Karger AG, Basel.

  12. The floating cardiac fat pad-sign of occult pneumothorax.

    Science.gov (United States)

    Kaufman, Claire; Bokhari, S A Jamal

    2016-08-01

    Pneumothoraces are a possible sequela of chest trauma with potential morbidity and mortality if not recognized and treated promptly. A portable supine chest radiograph is frequently the first radiologic study performed in the setting of trauma. While large pneumothoraces can be readily recognized on these radiographs, smaller pneumothoraces are missed in up to 15 % of trauma patients. There are many radiographic signs of occult pneumothoraces, and we are presenting a new radiographic sign of occult pneumothorax. The floating cardiac fat pad sign occurs when pleural air collects anteriorly and superiorly in the most non-dependent portion of the chest lifting the pericardial fat pad off the diaphragm. Lung markings are still seen surrounding the pericardial fat pad due to the inflated lower lobe of the lung resting dependently. Rapid and accurate identification of pneumothoraces is critical but often difficult on chest radiographs. Although there are many existing radiographic signs for identification of pneumothorax, prospective identification of small pneumothoraces is still relatively poor. Here, we describe an additional sign which aides in the detection of pneumothoraces, the floating cardiac fat pad. When present, this should prompt further evaluation with chest CT or upright chest radiograph.

  13. Impact of the rail-pad multi-discrete model upon the prediction of the rail response

    Science.gov (United States)

    Mazilu, T.; Leu, M.

    2017-08-01

    Wheel/rail vibration has many technical effects such as wear of the rolling surfaces, rolling noise, settlement of the ballast and subgrade etc. This vibration is depending on the rail pad characteristic and subsequently, it is important to have an accurate overview on the relation between the rail pad characteristic and the level of the wheel/rail vibration. To this end, much theoretical and experimental research has been developed in the past, and for the theoretical approach the track model, in general, and, particularly, the rail pad model is of crucial importance. Usually, the rail pad model is discrete model one, neglecting the length of the rail pad. This fact is questionable because the sleepers span is only 4 times the rail pad length. Using the rail pad discrete model, the rail response is overestimated when the frequency of the excitation equals the pinned-pinned resonance frequency. In this paper, a multi-discrete model for the rail pad, consisting in many Kelvin-Voigt parallel systems, is inserted into an analytical model of the track. The track model is reduced to a rail taken as infinite Timoshenko beam, discretely supported via rail pad, sleeper and ballast. The influence of the number of Kelvin-Voigt systems of the rail pad model on the rail response is analysed.

  14. iPad technology for home rehabilitation after stroke (iHOME): a proof-of-concept randomized trial.

    Science.gov (United States)

    Saposnik, Gustavo; Chow, Chi-Ming; Gladstone, David; Cheung, Donna; Brawer, Edward; Thorpe, Kevin E; Saldanha, Avon; Dang, Alice; Bayley, Mark; Schweizer, Tom A

    2014-10-01

    Tablets are a novel line of computers controlled by a multitouch screen. Fine motor movements are captured on the tablet computer through electrical fields and can be qualitatively and quantitatively assessed. Evidence is limited on tablet use for stroke rehabilitation. iHOME is an investigator-initiated randomized controlled pilot trial with a single-blinded outcome assessment. The intervention consists of iPad use (investigational group) vs. usual care (control group) among patients receiving conventional outpatient rehabilitation. Eligibility includes aged 18-85 years who experienced a mild ischemic or hemorrhagic stroke (as diagnosed on neuroimaging and determined by the Chedoke-McMaster score ≥3. The STROKE REHAB® software for the iPad was specifically designed for patients with fine motor weakness and/or neglect. Of the total 30 patients, 20 will be in iHOME Acute (enrolled within three-months of stroke onset) and 10 patients in iHOME Chronic (enrolled more than six-months from onset). The primary feasibility outcome is the proportion of the scheduled iPad time used (more than 70% (≥140 mins) of the total 'dose' of intervention intended will be considered successful). Efficacy in fine motor movements will be assessed using the nine-hole peg test; time to magnify and pop the balloons in the iPad software application, and improvement in Wolf Motor Function Test. iHOME is a randomized controlled trial assessing the feasibility, safety, and efficacy of tablet technology for home use in stroke rehabilitation. The results of this study will serve as the basis for a larger multicenter trial. © 2014 World Stroke Organization.

  15. Effect of Gender on Mechanical Properties of the Plantar Fascia and Heel Fat Pad.

    Science.gov (United States)

    Taş, Serkan

    2017-10-01

    The purpose of the study was to investigate the plantar fascia and heel fat pad stiffness and thickness parameters in females and compare these values with those of males. This study was carried out in 60 healthy sedentary participants (30 female, 30 male) between the ages of 19 and 50 years. Shear wave velocity (SWV) and thickness of the plantar fascia and heel fat pad were measured with an ultrasonography device. Males had a higher plantar fascia ( P = .037) and heel fat pad ( P = .001) thickness compared with females, but SWV of the plantar fascia ( P = .673), heel fat pad microchamber layer ( P = .240), and heel fat pad macrochamber layer ( P = .636) were similar in both groups. Body mass had a strong correlation with the plantar fascia ( r = 0.64, P plantar fascia ( r = 0.44, P Plantar fascia and heel fat pad stiffness were similar in both genders; however, females had a lower plantar fascia and heel fat pad thickness compared with males. Correlation analysis results suggest that higher plantar fascia and heel fat pad thickness in males may be related to higher body mass and height. Level III, Retrospective comparative study.

  16. Nappy pad urine samples for investigation and treatment of UTI in young children: the ‘DUTY’ prospective diagnostic cohort study

    Science.gov (United States)

    Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-01-01

    Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678

  17. How does the presence of excreta affect the behavior of laying hens on scratch pads?

    Science.gov (United States)

    Pokharel, B B; Boecker, I; Kwon, I Y; Jeyachanthiran, L; McBride, P; Harlander-Matauschek, A

    2018-03-01

    Enriched cages for laying hens provide scratch pads for foraging on the wire mesh floors. Apart from foraging on scratch pads, hens also defecate on these pads, causing them to become soiled with excreta. This study was conducted to determine the relative preference of laying hens for foraging on clean (C) scratch pads or scratch pads soiled with excreta (E), and to study the behaviors performed by hens on such pads. A total of 288 laying hens was housed in 16 enriched cages (18 hens/cage), each divided into 2 compartments. On a daily basis, half of the scratch pads (one in each compartment) were removed and cleaned, while the other half were cleaned and then covered with 550 g (0.35 g/cm2) of conspecific excreta. The C and E scratch pads were then put back into the cages in a systematic order to avoid side bias. Feed was delivered automatically onto the scratch pads as a litter substrate. The frequency of visits and the total time spent performing different behaviors on C and E pads were video-recorded [the time of video recording was relative to litter (feed) delivery on the scratch pads] for a total of 10 min/d, 3 times/wk, over a period of 4 weeks. Overall, the allocation of the time budget for different behaviors was found to be-in order of greatest to least amount of time-resting, locomotor behaviors (walking and running), foraging, and dust bathing. Laying hens showed a relative preference for E scratch pads by visiting them more frequently (P = 0.001), and spent more time (P = 0.035) foraging on them, whereas they rested for more time (P hens. Similarly, the longer use of C scratch pads for resting indicates the need for an ideal and clean resting surface in enriched cages.

  18. Effect of a social script iPad application for children with autism going to imaging.

    Science.gov (United States)

    Johnson, Norah; Bree, Octavia; Lalley, Erin E; Rettler, Kelly; Grande, Pam; Gani, Md O; Ahamed, Sheikh I

    2014-01-01

    This randomized controlled trial feasibility study tested the effectiveness of an iPad® application (app) social script intervention for children with autism spectrum disorder (ASD) going to imaging and their parent (n=32 parent/child dyads). Parents of the children exposed to the app (n=16) had lower state anxiety compared to the parents whose children were not exposed to the app (n=16) (effect size 0.33). Children exposed to the app had fewer externalized challenging behaviors than the control group (effect size 0.56). The results demonstrate feasibility and efficacy of the intervention. Further study of the iPad app is warranted. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. A Study on quality improvement and application technology in pad-mounted transformers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soon Tae; Mun, Kyung Hwa; Jung, Dong Won; Kim, Sang Jun; Lee, Nam Woo; Kang, Nae Kuk; Kim, Dong Mung [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Kim, Kwang Ha; Kang, Young Sik; Lee, Woo Young; Lyu, Hee Suk; Sun, Jong Ho; Lyu, Hyung Ki; Kim, Yik Soo; Park, Sung Jae; Kim, Won Ho [Korea Electrotechnology Research Inst., Changwon (Korea, Republic of)

    1995-12-31

    In order to increase the reliability of pad-mounted transformers, the authors investigated operating condition of pad-mounted transformers and understood their failure mechanisms. The objective of their study was to improve quality and operating condition and install switches to be able to check and maintain transformers and optimise protection devices and increase cooling effect in pad-mounted transformers (author). 65 refs., 130 figs.

  20. The SciencePAD treasure hunt of Persistent Identifiers

    CERN Multimedia

    Beatrice Bressan, for the European Middleware Initiative (EMI)

    2013-01-01

    Have you ever followed a reference for an article that eventually turned out to be unavailable? Have you always thought that experiment data or research results should be permanently accessible? If so, you will probably be interested in the latest news on the current status of software and digital information issues, and you shouldn’t miss the SciencePAD Persistent Identifiers Workshop (SPID2013).   The workshop is being organised by the European Middleware Initiative (EMI) together with its SciencePAD (formerly known as ScienceSoft) project and will take place on 30 January 2013 at CERN. SciencePAD is a community-enabler, working on providing the necessary one-stop-shop tools, including software, catalogues, statistics, reference citation systems, marketplaces, technical services links, platform integration supports, etc. It allows researchers and open source software developers from scientific communities to interact with each other within and beyond their area of expertise, and co...

  1. A Scott bench with ergonomic thorax stabilisation pad improves body posture during preacher arm curl exercise.

    Science.gov (United States)

    Biscarini, Andrea; Benvenuti, Paolo; Busti, Daniele; Zanuso, Silvano

    2016-05-01

    We assessed whether the use of an ergonomic thorax stabilisation pad, during the preacher arm curl exercise, could significantly reduce the excessive shoulder protraction and thoracic kyphosis induced by the standard flat pad built into the existing preacher arm curl equipment. A 3D motion capture system and inclinometers were used to measure shoulder protraction and thoracic kyphosis in 15 subjects performing preacher arm curl with a plate-loaded machine provided with the standard flat pad. The same measures were repeated after replacing the flat pad with a new ergonomic pad, specifically designed to accommodate the thorax profile and improve body posture. Pad replacement significantly (p ergonomic pad may potentially allow a more effective training, prevent musculoskeletal discomfort and reduce the risk of injury. Practitioner summary: We have designed an ergonomic thorax stabilisation pad for the preacher arm curl exercise. The new ergonomic pad improves the poor posture conditions induced by the standard flat pad and may potentially allow a more effective training, prevent musculoskeletal discomfort, improve the breathing function and reduce the risk of injury.

  2. The PAD Class: a new paradigm for university classroom teaching

    Science.gov (United States)

    Zhang, Xuexin

    2017-08-01

    The PAD Class (Presentation-Assimilation-Discussion) is a new paradigm for classroom teaching combining strengths of lecture and discussion. With half class time allocated for teacher's presentation and the other half for students' discussion, an assimilation stage was inserted between presentation and discussion for independent and individualized learning. Since its first success in 2014, the PAD method has gained national popularity in China and been successfully put into practice by thousands of college teachers in nearly all subjects, e.g., science, engineering, medical sciences, social sciences, humanities and arts. This paper analyzed the psychological and pedagogical rationales underlying the PAD Class to explicate its effectiveness in enhancing active learning.

  3. Construction and characterization of the TL/TH thorium calibration pads

    International Nuclear Information System (INIS)

    Steele, W.D.

    1987-09-01

    The Technical Measurements Center (TMC) was established and was tasked with developing and/or recommending measurement methods for use in support of remedial action programs. Since one aspect of this technical support is the provision of calibration facilities for standardization of field measurements, four sets of thorium-232 enriched pads (two pads per set) were constructed for use by remedial action contractors in calibrating portable field instruments that are used to make direct, in-situ measurements of radium-226, thorium-232, and potassium-40. This report presents the design, construction, and characterization data of the eight calibration pads. 17 refs., 8 figs., 15 tabs

  4. Development of a Test Cell to Evaluate Embankment Infiltration

    International Nuclear Information System (INIS)

    Orton, T. L.

    2002-01-01

    Envirocare of Utah, Inc. (Envirocare) has developed and constructed a test pad to evaluate potential infiltration through the designed cover system over the low-level radioactive waste disposal embankments incorporated at the facility. The general design of the test pad follows the recommendations set forth in the Alternative Cover Assessment Program (ACAP) that is currently funded by the U.S. Environmental Protection Agency (EPA) to assess potential alternatives to conventional landfill cover designs. The bulk of the test pad is below grade with dimensions approximately 16 feet wide by 28 feet long. The base of the test pad is a lysimeter built to the same dimensions as compliance lysimeters within the disposal embankments at Envirocare. The lysimeter collects all liquids to a single low point and directs the liquids through monitoring instruments within a manhole outside the test pad. The lysimeter is constructed to simulate the ''top of waste'' condition in Envirocare's embankments; consequently, the top of the lysimeter is sloped at an angle of approximately 2.8 percent, the design top slope of the embankment. A replica of the embankment cover is constructed directly above the lysimeter. This cover is constructed exactly the same as final cover is constructed upon the waste disposal embankments, utilizing the same QA/QC measures. Permanent monitoring equipment has been placed during construction at specific intervals throughout the test pad. Monitoring equipment consists of water content reflectometers (WCRs), matric water potential sensors (heat dissipation units; HDUs), and temperature probes. The monitoring equipment provides cross-sectional data of the moisture content and temperatures throughout the constructed cover. Additionally, surface water runoff is collected through a drainage trough and measured in order to perform a water balance over the entire test pad. To aid in the assessment, data collected from the site meteorological stat ion will be used

  5. The Tablet Inscribed: Inclusive Writing Instruction with the iPad

    Science.gov (United States)

    Sullivan, Rebecca M.

    2013-01-01

    Despite the author's initial skepticism, a classroom set of iPads has reinforced a student-directed approach to writing instruction, while also supporting an inclusive classroom. Using the iPads, students guide their writing process with access to the learning management system, electronic information resources, and an online text editor. Students…

  6. SCIENTIFIC PROGRESS OF THE MC-PAD NETWORK

    CERN Document Server

    Aguilar, J; Ambalathankandy, P; Apostolakis, J; Arora, R; Balog, T; Behnke, T; Beltrame, P; Bencivenni, G; Caiazza, S; Dong, J; Heller, M; Heuser, J; Idzik, M; Joram, C; Klanner, R; Koffeman, E; Korpar, S; Kramberger, G; Lohmann, W; Milovanović, M; Miscetti, S; Moll, M; Novgorodova, O; Pacifico, N; Pirvutoiu, C; Radu, R; Rahman, S; Rohe, T; Ropelewski, L; Roukoutakis, F; Schmidt, C; Schön, R; Sibille, J; Tsagri, M; Turala, M; Van Beuzekom, M; Verheyden, R; Villa, M; Zappon, F; Zawiejski, L; Zhang, J

    2013-01-01

    MC-PAD is a multi-site Initial Training Network on particle detectors in physics experiments. It comprises nine academic participants, three industrial partners and two associated academic partners. 17 recruited Early Stage and 5 Experienced Researchers have performed their scientific work in the network. The research and development work of MC-PAD is organized in 12 work packages, which focus on a large variety of aspects of particle detector development, electronics as well as simulation and modelling. The network was established in November 2008 and lasted until October 2012 (48 months). This report describes the R&D activities and highlights the main results achieved during this period.

  7. Performance of an iPad Application to Detect Moderate and Advanced Visual Field Loss in Nepal.

    Science.gov (United States)

    Johnson, Chris A; Thapa, Suman; George Kong, Yu Xiang; Robin, Alan L

    2017-10-01

    To evaluate the accuracy and efficiency of Visual Fields Easy (VFE), a free iPad app, for performing suprathreshold perimetric screening. Prospective, cross-sectional validation study. We performed screening visual fields using a calibrated iPad 2 with the VFE application on 206 subjects (411 eyes): 210 normal (NL), 183 glaucoma (GL), and 18 diabetic retinopathy (DR) at Tilganga Institute of Ophthalmology, Kathmandu, Nepal. We correlated the results with a Humphrey Field Analyzer using 24-2 SITA Standard tests on 373 of these eyes (198 NL, 160 GL, 15 DR). The number of missed locations on the VFE correlated with mean deviation (MD, r = 0.79), pattern standard deviation (PSD, r = 0.60), and number of locations that were worse than the 95% confidence limits for total deviation (r = 0.51) and pattern deviation (r = 0.68) using SITA Standard. iPad suprathreshold perimetry was able to detect most visual field deficits with moderate (MD of -6 to -12 dB) and advanced (MD worse than -12 dB) loss, but had greater difficulty in detecting early (MD better than -6 dB) loss, primarily owing to an elevated false-positive response rate. The average time to perform the Visual Fields Easy test was 3 minutes, 18 seconds (standard deviation = 16.88 seconds). The Visual Fields Easy test procedure is a portable, fast, effective procedure for detecting moderate and advanced visual field loss. Improvements are currently underway to monitor eye and head tracking during testing, reduce testing time, improve performance, and eliminate the need to touch the video screen surface. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Knee Fat Pad Volumes in Patients with Hemophilia and Their Relationship with Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Annette von Drygalski

    2017-01-01

    Full Text Available Hemophilic arthropathy is a progressive, disabling condition with poorly understood pathobiology. Since there is an emerging interest to study the role of intra-articular fat pad size and biology in arthritic conditions, we explored fat pad volume changes in hemophilic arthropathy and to what extent they differed from osteoarthritis. We matched a cohort of 13 adult patients with hemophilic arthropathy of the knee with age- and gender-matched cohorts without osteoarthritis (“control cohort” and with the same degree of radiographic osteoarthritis (“OA cohort” in 1 : 2 fashion. Infrapatellar fat pad (IPFP and suprapatellar fat pad (SPFP volumes were calculated based on magnetic resonance imaging and differences in fat pad volumes, demographics, height, weight, and osteoarthritis scores were evaluated. Fat pad volumes were positively associated with body size parameters in all three cohorts but were unaffected by the degree of osteoarthritis. While IPFP volumes did not differ between cohorts, SPFP volumes expanded disproportionally with weight in hemophilia patients. Our observations indicate that IPFPs and SPFPs behave biologically differently in response to different arthritic stimuli. The exaggerated expansion of the SPFP in hemophilia patients highlights the importance of further studying the implications of fat pad biology for progression of hemophilic arthropathy.

  9. SCiPad: Effective Implementation of Telemedicine Using iPads with Individuals with Spinal Cord Injuries, a Case Series

    Directory of Open Access Journals (Sweden)

    Kazuko Shem

    2017-05-01

    Full Text Available BackgroundIndividuals with spinal cord injury (SCI must often travel long distances to see a rehabilitation specialist. While telemedicine (TM for pressure ulcer management has been used in this population, real-time video telecommunication using iPad has never been described.ObjectiveThe objective of this study was to provide specialized care for persons with SCI through TM consultation expediently in order to address medical needs, manage secondary complications, and to improve quality of life (QoL of individuals with SCI.MethodsTen individuals with SCI participated in the TM program using iPads for 6 months as a feasibility study at a single-center, county hospital. The participants contacted the project staff for SCI-related conditions and were then connected to an SCI-trained health-care provider within 24 hours via FaceTime. Main outcome measures included health-care utilization; QoL and psychosocial measures collected at baseline and at 6 months: Reintegration to Normal Living Index (RNLI, Life Satisfaction Index A (LSI-A, and Patient Health Questionnaire 9 (PHQ-9; and a Program Satisfaction Survey.ResultsTen patients (seven with tetraplegia, three with paraplegia; eight males and two females with an average age of 34.4 (18–54 years were enrolled. The average baseline and 6-month follow-up scores were RNLI—70.1 ± 19.7 and 74.7 ± 21.8, respectively; LSI-A—25.4 ± 7.4 and 26.4 ± 8.2, respectively; and PHQ-9 were 6.8 ± 7.2 and 8.6 ± 6.1, respectively. TM encounters included topics such as pain, bladder and skin management, medication changes, and lab results. The Program Satisfaction Survey yielded positive results with 100% of program completers stating they would recommend the program and would like to continue having TM.ConclusionThis is the first known successful project using iPad to provide TM in the SCI population. This study discusses the implementation of such a TM program in a health system

  10. The Neglected "R": Improving Writing Instruction through iPad Apps

    Science.gov (United States)

    Sessions, Laird; Kang, Mi Ok; Womack, Sue

    2016-01-01

    In this study the authors investigated the effects of integrating iPad applications into writing instruction for fifth grade students. By comparing the writing of students taught with paper and pencil methods with that of students utilizing the iPad writing applications, two research questions guided the study: (1) Are there differences in student…

  11. An algorithm for nonlinear thermal analysis of fuel bearing pads

    International Nuclear Information System (INIS)

    Attia, M.H.; D'Silva, N.

    1983-01-01

    An algorithm has been developed for accurate prediction of the temperature field in a CANDU fuel bearing pad and the extent of the nucleate boiling in the crevice region. The methodology recognizes the nonlinear nature of the problem due to the fact that local boiling is both controlling and being controlled by the conditions of heat transfer at the boundaries. The finite difference model accounts for the volumetric effect of the thermal contact resistance at the bearing pad/pressure tube interface. It also allows the evaluation of the thermal barrier effect caused by applying an oxide film on the radiused surface of the bearing pad. Information pertaining to the distribution of the coefficient of heat transfer over water-cooled surfaces has been generated. Analysis of the results indicated the significance of considering the nonlinear behaviour of the system in determining its state of equilibrium. It also indicated that, depending on the thickness of the oxide layer and the position of the bearing pad along the core of the reactor, the nucleate boiling process can be prevented

  12. Construction and characterization of the RH/RL radium calibration pads

    International Nuclear Information System (INIS)

    Steele, W.D.; Marutzky, S.J.; Dickerson, J.W.

    1989-01-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology has as one of its goals the standardization of field measurements made by its remedial action contractors throughout the country. In support of this goal, the Technical Measurements Center (TMC) was established at the DOE Grand Junction Projects Office (GJPO) Facility, and was tasked with developing and/or recommending measurement methods for use in support of remedial action programs. One aspect of this technical support is the provision of calibration facilities for standardization of field measurements. The report presents the results of the design, construction, and characterization of 14 calibration pads enriched in radium-226. The 14 pads comprise 7 sets with a high and low activity pad in each set. The pads are concrete cylinders, approximately 5 feet in diameter by 2 feet in height. They are intended for use in calibrating portable field instruments that are used by remedial action contractors to make direct, in situ measurements of radium-226, thorium-232, and potassium-40. 23 refs., 6 figs., 14 tabs

  13. Use of Doceri Software for iPad in Online Delivery of Chemistry Content

    Science.gov (United States)

    Silverberg, Lee J.; Tierney, John; Bodek, Matthew J.

    2014-01-01

    Doceri software for iPad is useful for both synchronous online and asynchronous online delivery of chemistry course content. Using the Doceri wireless connection between the iPad and a personal computer that is running Adobe Connect, online synchronous instruction can be accomplished in which drawings can be completed by hand on the iPad. For…

  14. iPad use at the bedside: a tool for engaging patients in care processes during ward rounds?

    Science.gov (United States)

    Baysari, M T; Adams, K; Lehnbom, E C; Westbrook, J I; Day, R O

    2014-10-01

    Previous work has examined the impact of technology on information sharing and communication between doctors and patients in general practice consultations, but very few studies have explored this in hospital settings. To assess if, and how, senior clinicians use an iPad to share information (e.g. patient test results) with patients during ward rounds and to explore patients' and doctors' experiences of information sharing events. Ten senior doctors were shadowed on ward rounds on general wards during interactions with 525 patients over 77.3 h, seven senior doctors were interviewed and 180 patients completed a short survey. Doctors reported that information sharing with patients is critical to the delivery of high-quality healthcare, but were not seen to use the iPad to share information with patients on ward rounds. Patients did not think the iPad had impacted on their engagement with doctors on rounds. Ward rounds were observed to follow set routines and patient interactions were brief. Although the iPad potentially creates new opportunities for information sharing and patient engagement, the ward round may not present the most appropriate context for this to be done. © 2014 The Authors; Internal Medicine Journal © 2014 Royal Australasian College of Physicians.

  15. Comparison of a Padded Patient Litter and Long Spine Board for Spinal Immobilization in Air Medical Transport.

    Science.gov (United States)

    Weber, Steven R; Rauscher, Patrick; Winsett, Rebecca P

    2015-01-01

    The long spinal board is the immobilization standard during prehospital transport. The flat surface of the board increases the pressure placed on both the thoracic kyphosis and the sacrum and increases the risk for pressure ulcers. This study compared patient stability and comfort between a padded litter system used in air medical transport and the long spine board. The study was completed at a large 350-bed Magnet Recognized nonteaching hospital. The hospital owns and operates an air medical transport service. Subjects were secured to a padded litter and a long spinal board with a cervical collar and head blocks and 3 straps. Laser pointers were used to mark neutral at points on the subject's head, sternum, and pelvis. The subject was tilted 45 degrees left and right with movement measured in inches. Comfort level was measured before and after. Paired t-tests were used to detect differences in movement. No statistical difference in movement was found between devices for the head; however, there was statistically significant greater movement on the padded litter for the sternum and pelvis. The padded litter did not immobilize as tightly as the long board although the effect of the differences was small. Copyright © 2015 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  16. Rotordynamic Evaluation of Full Scale Rotor on Tilting Pad Bearings with 0.1 and 0.3 Preload

    Directory of Open Access Journals (Sweden)

    Weimin Wang

    2014-01-01

    Full Text Available A system identification method for rotating machinery stability evaluation is investigated based on sine sweep excitation testing with electromagnetic actuator. The traditional MIMO FRF is transformed into dFRF from real number field to complex field with a transformation matrix, eliminating the influence of forward and backward modal overlap and providing higher accuracy to identify rotor’s first forward modal parameters using the rational polynomial method. The modal parameters are acquired for stability estimation. Furthermore, two sets of bearing with preloads of 0.1 and 0.3 under both load-on-pad (LOP and load-between-pad (LBP conditions are investigated. The effects of oil inlet pressure (1.0 bar–1.75 bar and temperature (43°C–51°C on the stability of rotor are investigated in detail. Results indicate that the stability of rotor will be improved by increasing the oil inlet temperature and pressure. It is found that the rotor is more stable on bearing with 0.1 preload than that of 0.3 preload. Load-on-pad provides more damping to rotor than load-between-pad. The method and outcomes of this paper can provide both theory basis and technology foundation for improving the rotor stability of centrifugal compressors.

  17. Development of tire road noise chassis-dynamometer simulator. Effect of ISO surface replica model pad on tire road noise; Shisakushita tire romen soon shiken`yo jissha daijo simulator ni tsuite. ISO romen mogi pad wo sochakushita koka ni kansuru kisoteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Murakami, T; Ogata, S; Sakamoto, I [Traffic Safety and Nuisance Research Inst., Tokyo (Japan)

    1997-10-01

    As a new test facility to clarify noise reduction method of tire road noise, Tire Road Noise Chassis-Dynamometer Simulator was developed. ISO surface replica pads made by copying the texture of ISO surface were attached on the roller surface of this system to simulate tire road noise. This paper described the specifications and characteristics of this system, and the effects of ISO surface replica pads on tire noise measurement by comparing the sound intensity in horizontal plane of tire noise measured in this system with that measured in a single drum tester with safety walk surface. 4 refs., 10 figs., 1 tab.

  18. Exploring the Use of the iPad for Literacy Learning

    Science.gov (United States)

    Hutchison, Amy; Beschorner, Beth; Schmidt-Crawford, Denise

    2012-01-01

    The goal of this investigation was to explore how a fourth grade teacher could integrate iPads into her literacy instruction to simultaneously teach print-based and digital literacy goals. The teacher used iPads for a three-week period during her literacy instruction and selected apps that provided unique approaches to helping the students meet…

  19. Another Perspective: The iPad Is a REAL Musical Instrument

    Science.gov (United States)

    Williams, David A.

    2014-01-01

    This article looks at the iPad's role as a musical instrument through the lens of a live performance ensemble that performs primarily on iPads. It also offers an overview of a pedagogical model used by this ensemble, which emphasizes musician autonomy in small groups, where music is learned primarily through aural means and concerts are…

  20. Engaging Organic Chemistry Students Using ChemDraw for iPad

    Science.gov (United States)

    Morsch, Layne A.; Lewis, Michael

    2015-01-01

    Drawing structures, mechanisms, and syntheses is a vital part of success in organic chemistry courses. ChemDraw for iPad has been used to increase classroom experiences in the preparation of high quality chemical drawings. The embedded Flick-to-Share allows for simple, real-time exchange of ChemDraw documents. ChemDraw for iPad also allows…

  1. Improvement of Thrust Bearing Calculation Considering the Convectional Heating within the Space between the Pads

    OpenAIRE

    Monika Chmielowiec-Jablczyk; Andreas Schubert; Christian Kraft; Hubert Schwarze; Michal Wodtke; Michal Wasilczuk

    2018-01-01

    A modern thrust bearing tool is used to estimate the behavior of tilting pad thrust bearings not only in the oil film between pad and rotating collar, but also in the space between the pads. The oil flow in the space significantly influences the oil film inlet temperature and the heating of pad and collar. For that reason, it is necessary to define an oil mixing model for the space between the pads. In the bearing tool, the solutions of the Reynolds equation including a cavitation model, the ...

  2. ATLANTIS ROLLS OUT TO PAD 39A FOLLOWING HURRICANE FRAN THREAT

    Science.gov (United States)

    1996-01-01

    A view from the flame trench looking up shows the Space Shuttle Atlantis, mounted on the Mobile Launcher Platform and Crawler- Transporter, as it arrives atop the hardstand at Launch Pad 39A. After the Shuttle and launch stand are in position, the crawler will be pulled back. This is the third time Atlantis has completed the journey to Launch Pad 39A in the STS-79 mission flow. The Shuttle was rolled back from the pad in July due to the threat from Hurricane Bertha, then rolled back again earlier this week because of Hurricane Fran. The targeted launch date for Atlantis on Mission STS-79 -- the fourth docking between the U.S. Shuttle and Russian Space Station Mir -- is now Sept. 16 at 4:54 a.m. EDT. The three rollout dates for Atlantis to Pad 39A are: July 1, Aug. 20 and Sept. 5.

  3. Experimental evaluation of the performances of cellulosic pads made out of Kraft and NSSC corrugated papers as evaporative media

    International Nuclear Information System (INIS)

    Barzegar, Mahsa; Layeghi, Mohammad; Ebrahimi, Ghanbar; Hamzeh, Yahya; Khorasani, Manouchehr

    2012-01-01

    Highlights: ► We experimentally evaluated the performances of cellulosic pads. ► A number of experiments have been done in a wind tunnel. ► The results showed that cooling efficiency improves with decrease of air velocity and flute size. ► Water consumption increases with the increase of air velocity. ► Cooling efficiency of various pads was also compared. - Abstract: The purpose of this study was to evaluate the performances of cellulosic pads made out of Kraft and NSSC corrugated papers in three flute sizes, experimentally. A number of experiments have been done in a wind tunnel in order to evaluate the cooling efficiency and water consumption as a function of air velocity. The tests were carried out at three levels of air velocity (1.8, 2.25, and 2.67 ms −1 ) for three flute sizes of Kraft and NSSC corrugated papers (2.5, 3.5, and 4.5 mm). Analysis of the results indicated that cooling efficiency improves with decrease of air velocity and flute size of corrugated papers; however, water consumption increases with the increase of air velocity. The results were compared with each other and it was shown that the cellulosic pad made out of Kraft paper with 2.5 mm flute size has the highest performance (92%) at 1.8 ms −1 air velocity in comparison with the other cellulosic pads.

  4. MWPC with highly segmented cathode pad readout

    International Nuclear Information System (INIS)

    Debbe, R.; Fischer, J.; Lissauer, D.

    1989-01-01

    Experiments being conducted with high energy heavy ion beams at Brookhaven National Laboratory and at CERN have shown the importance of developing position sensitive detectors capable of handling events with high multiplicity in environments of high track density as will also be the case in future high luminosity colliders like SSC and RHIC. In addition, these detectors are required to have a dynamic range wide enough to detect minimum ionizing particles and heavy ions like oxygen or silicon. We present here a description of work being done on a prototype of such a detector at BNL. Results from a similar counter are also presented in this Conference. The ''pad chamber'' is a detector with a cathode area subdivided into a very large number of pixel-like elements such that a charged particle traversing the detector at normal incidence leaves an induced charge on a few localized pads. The pads are interconnected by a resistive strip, and readout amplifiers are connected to the resistive strip at appropriate, carefully determined spacings. The pattern of tracks in a multi-hit event is easily recognized, and a centroid-finding readout system allows position determination to a small fraction of the basic cell size. 5 refs., 9 figs

  5. Improvement of Thrust Bearing Calculation Considering the Convectional Heating within the Space between the Pads

    Directory of Open Access Journals (Sweden)

    Monika Chmielowiec-Jablczyk

    2018-02-01

    Full Text Available A modern thrust bearing tool is used to estimate the behavior of tilting pad thrust bearings not only in the oil film between pad and rotating collar, but also in the space between the pads. The oil flow in the space significantly influences the oil film inlet temperature and the heating of pad and collar. For that reason, it is necessary to define an oil mixing model for the space between the pads. In the bearing tool, the solutions of the Reynolds equation including a cavitation model, the energy equation and the heat transfer equation are done iteratively with the finite volume method by considering a constant flow rate. Both effects—laminar/turbulent flow and centrifugal force—are considered. The calculation results are compared with measurements done for a flooded thrust bearing with nominal eight tilting pads with an outer diameter of 180 mm. The heat convection coefficients for the pad surfaces mainly influence the pad temperature field and are adjusted to the measurement results. In the following paper, the calculation results for variable space distances, influence of different parameters on the bearing behavior and operating condition at high load are presented.

  6. Placement of the Left Side AED Pad is Poor: Training on the Left Compared to the Right Side of a Manikin Does Not Improve Pad Placement

    DEFF Research Database (Denmark)

    Stærk, Mathilde; Bødtker, Henrik; Rahbek, Søren

    2015-01-01

    participating in a first aid course were randomized to learn automated external defibrillation sitting on the left or right side of a manikin during AED training. After course completion participants operated a training AED (Lifepak® CR-T AED Trainer, PhysioControl) and placed AED pads according to instructions...... volunteers were included and randomized to AED training on the left (n=14, 43% male, age: 47.9 years) and right (n=16, 25% male, age: 46.7 years) side of a manikin. There was no difference in left pad placement when trained on the left or right side (distance to recommended left apical pad position (mean...

  7. Effects of roads and well pads on erosion in the Largo Canyon watershed, New Mexico, 2001-02

    Science.gov (United States)

    Matherne, Anne Marie

    2006-01-01

    Largo Canyon, located in the San Juan Basin of northwestern New Mexico, is one of the longest dry washes in the world. Oil and gas production in the San Juan Basin, which began in the 1940's, required the development of an extensive network of dirt roads to service the oil and gas wells in the Navajo Reservoir area. Presently, there are about eight wells per square mile, and the density of oil and gas wells is expected to increase. Potential environmental effects on landscape stability that may result from the additional roads and well pads have not been documented. In 2001, the U.S. Geological Survey began a study in cooperation with the Bureau of Land Management to evaluate the effects of roads and well pads associated with oil and gas operations on the erosion potential of Bureau of Land Management lands in the Largo Canyon watershed. The effects of roads and well pads on erosion were quantified by installing sediment dams (dams) and by surveying transects across roads and well pads. Data from 26 dams were used in the analysis. Dams were installed at 43 sites: 21 on hillsides upslope from roads or pads to measure erosion from hillslopes, 11 at the downslope edges of roads to measure erosion from roads, and 11 at the downslope edges of well pads to measure erosion from well pads. Pairs of survey transects were established at nine well pads and two road locations. Sediment-accumulation data for 26 dams, recorded at 17 measurement intervals, indicate that average erosion rates at the dams significantly correlate to size of the contributing area. The average erosion rate normalized by drainage area was 0.001 foot per year below roads, 0.003 foot per year on hillslopes, and 0.011 foot per year below well pads. Results of a two-sample t-test indicate that there was no significant difference in average erosion rates for dams located on hillslopes and below roads, whereas average erosion rates were significantly greater for dams below well pads than for dams on

  8. Focused Molding Using Adhesive Pads in Mehta Casting for Early-Onset Scoliosis.

    Science.gov (United States)

    Abraham, Roby; Sponseller, Paul D

    2014-11-01

    Prospective clinical series. To determine the effect of adhesive pads placed over the apex of scoliosis curves on curve correction 1) after the first cast and 2) after the final cast. Early-onset scoliosis is often effectively managed by serial casting. Properly localizing the apex of the molds with the cast in place is challenging. The authors explored the effectiveness of a novel technique: incorporation of adhesive pads placed over the major curve apex before Mehta casting. The 27 patients who received body casts (2000-2013) were divided into 2 groups: those without and with apical adhesive pads (5-6 layers of pads placed on the major curve's apex during casting): non-pad (NP) group (n = 12) and pad (P) group (n = 15), respectively. Groups were compared regarding the percentage of Cobb angle change from the first cast and curve correction to a Cobb angle of cast curve correction was 39% ± 18% and 56% ± 17% in the NP and P groups, respectively. Of the 26 patients out of a cast, 11 (42%) had a Cobb angle of casting were effective in increasing the amount of major curve correction from the first cast for idiopathic early-onset scoliosis and in decreasing curves to <25° at final follow-up. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  9. Expanding the role of the iPad and tablet devices to cosmetic patient consultations.

    Science.gov (United States)

    Wang, Jing; Hsu, Jeffrey T S; Bhatia, Ashish C

    2012-09-01

    The iPad is a useful reference tool for patient education in cosmetic consultations. In this article, we plan to (1) discuss how the iPad can be implemented and used by patients and physicians in consultations, (2) compare the advantages and disadvantages of the iPad with other forms of technology, (3) discuss the optimal way of using the iPad for patient care, (4) see how this tool complies with privacy regulations, and (5) look at other uses of the iPad in the patient care setting. There has been positive feedback from both patients and physicians regarding the addition of the tablet computer during consultations. In addition to showing patients pictures of cosmetic procedures, the iPad also has various multimedia capabilities such as videos and drawing tools that are useful in optimizing patient satisfaction, increasing clinical efficacy, and improving the overall patient experience. Copyright © 2012. Published by Elsevier Inc.

  10. Kinetic energy absorbing pad

    International Nuclear Information System (INIS)

    Bricmont, R.J.; Hamilton, P.A.; Ming Long Ting, R.

    1981-01-01

    Reactors, fuel processing plants etc incorporate pipes and conduits for fluids under high pressure. Fractures, particularly adjacent to conduit elbows, produce a jet of liquid which whips the broken conduit at an extremely high velocity. An enormous impact load would be applied to any stationary object in the conduit's path. The design of cellular, corrugated metal impact pads to absorb the kinetic energy of the high velocity conduits is given. (U.K.)

  11. Lateral Vibration of Hydroelectric Generating Set with Different Supporting Condition of Thrust Pad

    Directory of Open Access Journals (Sweden)

    Xiaohui Si

    2011-01-01

    Full Text Available The variations of the supporting condition, which change the stiffness of tilting pad thrust bearing, may alter the dynamic behavior of the rotor system. The effects of supporting condition of thrust pad on the lateral vibration of a hydroelectric generating set are investigated in this paper. The action of a thrust bearing is described as moments acting on the thrust collar, and the tilting stiffness coefficients of thrust bearing are calculated. A model based on typical beam finite element method is established to calculate the dynamic response, and the effects of supporting conditions such as elastic oil tank support, different heights of the thrust pads with rigid support are discussed. The results reveal that the influence of thrust bearing is small when the elastic oil tanks work normally. When the supporting conditions turn to be rigid due to the oil leakage, the differences of thrust pad heights have evident influence on the load distribution of the thrust pads; while the effects on the tilting stiffness of the thrust bearing and the amplitude of the lateral shaft vibration is small when the maximum load on thrust pads is smaller than the allowable value.

  12. Method for Producing Launch/Landing Pads and Structures Project

    Science.gov (United States)

    Mueller, Robert P. (Compiler)

    2015-01-01

    Current plans for deep space exploration include building landing-launch pads capable of withstanding the rocket blast of much larger spacecraft that that of the Apollo days. The proposed concept will develop lightweight launch and landing pad materials from in-situ materials, utilizing regolith to produce controllable porous cast metallic foam brickstiles shapes. These shapes can be utilized to lay a landing launch platform, as a construction material or as more complex parts of mechanical assemblies.

  13. The effect of bedding system selected by manual muscle testing on sleep-related cardiovascular functions.

    Science.gov (United States)

    Kuo, Terry B J; Li, Jia-Yi; Lai, Chun-Ting; Huang, Yu-Chun; Hsu, Ya-Chuan; Yang, Cheryl C H

    2013-01-01

    Different types of mattresses affect sleep quality and waking muscle power. Whether manual muscle testing (MMT) predicts the cardiovascular effects of the bedding system was explored using ten healthy young men. For each participant, two bedding systems, one inducing the strongest limb muscle force (strong bedding system) and the other inducing the weakest limb force (weak bedding system), were identified using MMT. Each bedding system, in total five mattresses and eight pillows of different firmness, was used for two continuous weeks at the participant's home in a random and double-blind sequence. A sleep log, a questionnaire, and a polysomnography were used to differentiate the two bedding systems. Heart rate variability and arterial pressure variability analyses showed that the strong bedding system resulted in decreased cardiovascular sympathetic modulation, increased cardiac vagal activity, and increased baroreceptor reflex sensitivity during sleep as compared to the weak bedding system. Different bedding systems have distinct cardiovascular effects during sleep that can be predicted by MMT.

  14. ClimatePad: Enabling public exploration of climate data

    Science.gov (United States)

    Walsh, J. E.; Chapman, W. L.

    2012-12-01

    Informal learners interested in climate issues can find a wealth of information in the print and online media related to climate and climate change. Throughout these resources, the equal use of generic terms like 'global warming' and 'climate change' suggest a level of nuance in the science that is not easy to convey in this conventional media. Perhaps more than any other discipline, climate literacy has the most potential to be enhanced via the process of cognitive construction and reconstruction, rather than simple transmission of knowledge. Constructionism suggests that meaningful learning happens most effectively if the learner is actively engaged in constructing a product in the real world rather than absorbing information passively. Recent technological innovations have introduced mobile computing devices with sufficient power to do serious data analysis. The potential of these devices to augment climate literacy by turning citizens into scientists has yet to be exploited. We introduce ClimatePad, an iPad application that permits students and public to actively browse climate datasets, construct trends, plot time series, create composite differences and view animations of real-world climate data. Interactions with the ClimatePad permits varying the starting and ending dates of trends and differences. Climate analysis maps and animations can be customized with different color palettes, enticing the user to delve into and absorb the subtleties of the regional and temporal variations of the recent climate record. Finally, user-generated climate visualizations created with ClimatePad can be emailed to friends and shared via Facebook, entraining even more active learners.

  15. The diagnostic reliability of the quantitative pivot-shift evaluation using an electromagnetic measurement system for anterior cruciate ligament deficiency was superior to those of the accelerometer and iPad image analysis.

    Science.gov (United States)

    Tanaka, Toshikazu; Hoshino, Yuichi; Miyaji, Nobuaki; Ibaragi, Kazuyuki; Nishida, Kyohei; Nishizawa, Yuichiro; Araki, Daisuke; Kanzaki, Noriyuki; Matsushita, Takehiko; Kuroda, Ryosuke

    2017-10-14

    Several non-invasive devices have been developed to obtain quantitative assessment of the pivot-shift test in clinical setting using similar but diverse measurement parameters. However, the clinical usability of those measurements has yet to be closely investigated and compared. The purpose of this study was to compare the diagnostic accuracy of three non-invasive measurement devices for the pivot-shift test. Thirty patients with unilateral anterior cruciate ligament (ACL) injury were enrolled. The pivot-shift test was performed under general anaesthesia. Three devices, an accelerometer system (KiRA), an image analysis iPad application (iPad), and electromagnetic measurement system (EMS), were used simultaneously to provide two parameters, namely tibial acceleration monitored using KiRA and EMS, and tibial translation recorded using iPad and EMS. Side-to-side differences in each parameter and correlation between the measurements were tested, and a receiver-operating characteristic (ROC) curve analysis was conducted to compare their measurement accuracy. Significant side-to-side differences were successfully detected using any of the measurements (all p iPad and the EMS for the translation (r = 0.28; p iPad for tibial acceleration and translation, respectively. Although all three measurements were similarly capable of detecting ACL deficiency, the EMS has the advantage of comprehensive evaluation of the pivot-shift test by evaluating both tibial acceleration and translation with higher accuracy than those of KiRA and iPad. It could be suggested that any of those measurement tools might improve the clinical diagnosis of ACL insufficiency. Diagnostic study of consecutive patients with a universally applied gold standard, Level Ib.

  16. Physicochemical characterization of cactus pads from Opuntia dillenii and Opuntia ficus indica.

    Science.gov (United States)

    Méndez, Lorena Pérez; Flores, Fidel Tejera; Martín, Jacinto Darias; Rodríguez Rodríguez, Elena M; Díaz Romero, Carlos

    2015-12-01

    Physicochemical characteristics (weight, length, width, thickness, moisture, Brix degree, total fiber, protein, ash, pH, acidity, ascorbic acid, total phenolic compounds, P, Na, K, Ca, Mg, Fe, Cu, Zn, Mn and Cr) were determined in cactus pads from Opuntia dillenii and Opuntia ficus indica. The physicochemical characteristics of both species were clearly different. There were important differences between the orange and green fruit pulp of O. ficus indica; the cactus pads of O. dillenii could be differentiated according to the region (North and South). Consumption of cactus pads contributes to the intake of dietary fiber, total phenolic compounds, K, Mg, Mn and Cr. Applying factor and/or discriminant analysis, the cactus pad samples were clearly differentiated according to the species, the fruit pulp color and production region. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Padé approximant for normal stress differences in large-amplitude oscillatory shear flow

    Science.gov (United States)

    Poungthong, P.; Saengow, C.; Giacomin, A. J.; Kolitawong, C.; Merger, D.; Wilhelm, M.

    2018-04-01

    Analytical solutions for the normal stress differences in large-amplitude oscillatory shear flow (LAOS), for continuum or molecular models, normally take the inexact form of the first few terms of a series expansion in the shear rate amplitude. Here, we improve the accuracy of these truncated expansions by replacing them with rational functions called Padé approximants. The recent advent of exact solutions in LAOS presents an opportunity to identify accurate and useful Padé approximants. For this identification, we replace the truncated expansion for the corotational Jeffreys fluid with its Padé approximants for the normal stress differences. We uncover the most accurate and useful approximant, the [3,4] approximant, and then test its accuracy against the exact solution [C. Saengow and A. J. Giacomin, "Normal stress differences from Oldroyd 8-constant framework: Exact analytical solution for large-amplitude oscillatory shear flow," Phys. Fluids 29, 121601 (2017)]. We use Ewoldt grids to show the stunning accuracy of our [3,4] approximant in LAOS. We quantify this accuracy with an objective function and then map it onto the Pipkin space. Our two applications illustrate how to use our new approximant reliably. For this, we use the Spriggs relations to generalize our best approximant to multimode, and then, we compare with measurements on molten high-density polyethylene and on dissolved polyisobutylene in isobutylene oligomer.

  18. Dermal exposure assessment to benzene and toluene using charcoal cloth pads

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Tielemans, E.; Vermeulen, R.; Wegh, H.; Kromhout, H.

    2005-01-01

    Charcoal cloth pads have been used to assess volatile chemicals on the skin in a laboratory setting; however, they have not yet been applied to measure dermal exposure in occupational settings. This study aimed at evaluating whether charcoal pads can be used to assess dermal exposure to benzene and

  19. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. The use of an iPad to collect patient-reported functional outcome measures in hand surgery.

    Science.gov (United States)

    Yaffe, Mark; Goyal, Nitin; Kokmeyer, Daniel; Merrell, Gregory A

    2015-09-01

    The purpose of this study was to evaluate (1) patient preferences regarding iPad and paper-based questionnaires, (2) the efficacy of iPad and paper questionnaires in a hand surgery practice, (3) the influence of questionnaire length on patient preferences and data collection, and (4) patient characteristics associated with a preference for iPad-based questionnaires. Two hundred total patients in a single hand surgery practice were randomly assigned to one of four groups. Each group completed either the Michigan Hand Questionnaire (MHQ) or QuickDASH (QD) using either an iPad or pen and paper. Patient preferences, questionnaire completion and timing, and demographic data were analyzed. The use of an iPad was associated with a statistically stronger preference for the same delivery format in the future compared to paper for the MHQ (93.9 vs 52.1 %, p iPad group found the survey "physically easy" more often compared to the MHQ paper group, while no difference was found among QD groups. Questionnaire timing between iPad and paper groups was similar for the MHQ but statistically longer with the iPad for QD. A significantly higher proportion of patients who preferred the iPad were under the age of 50 compared to those who preferred paper. The addition of an iPad is an efficient and preferable questionnaire format for functional outcome assessment in a hand and upper extremity surgery practice setting. The iPad is particularly preferable for longer outcome questionnaires and for patients under the age of 50.

  1. An approach to evaluate capacitance, capacitive reactance and resistance of pivoted pads of a thrust bearing

    Science.gov (United States)

    Prashad, Har

    1992-07-01

    A theoretical approach is developed for determining the capacitance and active resistance between the interacting surfaces of pivoted pads and thrust collar, under different conditions of operation. It is shown that resistance and capacitive reactance of a thrust bearing decrease with the number of pads times the values of these parameters for an individual pad, and that capacitance increases with the number of pads times the capacitance of an individual pad. The analysis presented has a potential to diagnose the behavior of pivoted pad thrust bearings with the angle of tilt and the ratio of film thickness at the leading to trailing edge, by determining the variation of capacitance, resistance, and capacitive reactance.

  2. Eco-friendly asbestos free brake-pad: Using banana peels

    Directory of Open Access Journals (Sweden)

    U.D. Idris

    2015-07-01

    Full Text Available The use of asbestos fibre is being avoided due to its carcinogenic nature that might cause health risks. A new brake pad produced using banana peel waste to replace asbestos and Phenolic resin (phenol formaldehyde, as a binder was investigated. The resin was varying from 5 to 30 wt% with an interval of 5 wt%. Morphology, physical, mechanical and wear properties of the brake pad were studied. The results show that compressive strength, hardness and specific gravity of the produced samples were seen to be increasing with an increase in wt% of resin addition, while oil soak, water soak, wear rate and percentage charred decreased as the wt% of resin increased. Overall samples, containing 25 wt% in uncarbonized banana peels (BUNCp and 30 wt% in carbonized (BCp gave better properties. The result of this research indicates that banana peel particles can be effectively used as a replacement for asbestos in brake pad manufacture.

  3. Aspects regarding manufacturing technologies of composite materials for brake pad application

    Science.gov (United States)

    Craciun, A. L.; Hepuţ, T.; Pinca-Bretotean, C.

    2018-01-01

    Current needs in road safety, requires the development of new technical solutions for automotive braking system. Their safe operation is subject to following factors: concept design, materials used and electronic control. Among the factors previously listed, choice of materials and manufacturing processes are difficult stage but very important for achieving technical performance and getting a relatively small cost of constituting parts of brake system. The choice is based on the promotion of organic composite material, popular in areas where the weight of materials plays an important role. The brake system is composed of many different parts including brake pads, a master cylinder, wheel cylinders and a hydraulic control system. The brake pads are an important component in the braking system of automotive. These are of different types, suitable for different types of automotive and engines. Brake pads are designed for friction stability, durability, minimization of noise and vibration. The typology of the brake pads depends on the material which they are made. The aim of this paper is to presents the manufacturing technologies for ten recipes of composite material used in brake pads applications. In this work will be done: choosing the constituents of the recipes, investigation of their basic characteristics, setting the proportions of components, obtaining the composite materials in laboratory, establishing the parameters of manufacturing technology and technological analysis.

  4. Reducing friction in tilting-pad bearings by the use of enclosed recesses

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar

    2008-01-01

    A three-dimensional thermoelastohydrodynamic model is applied to the analysis of tilting-pad bearings with spherical pivots and equipped with deep recesses in the high-pressure regions. A potential for a 10-20% reduction in the friction loss compared to conventional plain bearing pads is documented....... Design suggestions minimizing the power loss are given for various length-to-width ratios. The tilting angle in the sliding direction is more sensitive to correct positioning of the pivot point than conventional bearing pads. Improving the performance by equipping a tilting-pad bearing with a deep recess...... therefore requires accurate analysis and design of the bearing. Similarly, a high sensitivity perpendicular to the sliding direction suggests that this method of reducing friction is more feasible when using line pivots or spring beds than when using spherical pivots for controlling the tilting angle....

  5. Digital representation of oil and natural gas well pad scars in southwest Wyoming: 2012 update

    Science.gov (United States)

    Garman, Steven L.; McBeth, Jamie L.

    2015-01-01

    The recent proliferation of oil and natural gas energy development in the Greater Green River Basin of southwest Wyoming has accentuated the need to understand wildlife responses to this development. The location and extent of surface disturbance that is created by oil and natural gas well pad scars are key pieces of information used to assess the effects of energy infrastructure on wildlife populations and habitat. A digital database of oil and natural gas pad scars had previously been generated from 1-meter (m) National Agriculture Imagery Program imagery (NAIP) acquired in 2009 for a 7.7-million hectare (ha) (19,026,700 acres) region of southwest Wyoming. Scars included the pad area where wellheads, pumps, and storage facilities reside and the surrounding area that was scraped and denuded of vegetation during the establishment of the pad. Scars containing tanks, compressors, the storage of oil and gas related equipment, and produced-water ponds were also collected on occasion. This report updates the digital database for the five counties of southwest Wyoming (Carbon, Lincoln, Sublette, Sweetwater, Uinta) within the Wyoming Landscape Conservation Initiative (WLCI) study area and for a limited portion of Fremont, Natrona, and Albany Counties using 2012 1-m NAIP imagery and 2012 oil and natural gas well permit information. This report adds pad scars created since 2009, and updates attributes of all pad scars using the 2012 well permit information. These attributes include the origination year of the pad scar, the number of active and inactive wells on or near each pad scar in 2012, and the overall status of the pad scar (active or inactive). The new 2012 database contains 17,404 pad scars of which 15,532 are attributed as oil and natural gas well pads. Digital data are stored as shapefiles projected to the Universal Transverse Mercator (zones 12 and 13) coordinate system. These data are available from the U.S. Geological Survey (USGS) at http://dx.doi.org/10

  6. Seismic tipping analysis of a spent nuclear fuel shipping cask sitting on a crush pad

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Hawkes, B.D.

    1998-04-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of an accidentally dropped spent nuclear fuel shipping cask into a 44 ft. deep cask unloading pool. Conventional analysis techniques available for evaluating a cask for tipping due to lateral seismic forces assume that the cask rests on a rigid surface. In this analysis, the cask (110 tons) sits on a stainless steel encased (0.25 in. top plate), polyurethane foam (4 ft. thick) crush pad. As the cask tends to rock due to horizontal seismic forces, the contact area between the cask and the crush pad is reduced, increasing the bearing stress, and causing the pivoting corner of the cask to depress into the crush pad. As the crush pad depresses under the cask corner, the pivot point shifts from the corner toward the cask center, which facilitates rocking and potential tipping of the cask. Subsequent rocking of the cask may deepen the depression, further contributing to the likelihood of cask tip over. However, as the depression is created, the crush pad is absorbing energy from the rocking cask. Potential tip over of the cask was evaluated by performing a non-linear, dynamic, finite element analysis with acceleration time history input. This time history analysis captured the effect of a deforming crush pad, and also eliminated conservatisms of the conventional approaches. For comparison purposes, this analysis was also performed with the cask sitting on a solid stainless steel crush pad. Results indicate that the conventional methods are quite conservative relative to the more exacting time history analysis. They also indicate that the rocking motion is less on the foam crush pad than on the solid stainless steel pad

  7. Office for iPad and Mac for dummies

    CERN Document Server

    Weverka, Peter

    2015-01-01

    The easy way to work with Office on your iPad or Mac Are you a Mac user who isn't accustomed to working with Microsoft Office? Consider this friendly guide your go-to reference! Written in plain English and packed with easy-to-follow, step-by-step instructions, Office for iPad and Mac For Dummies walks you through every facet of Office, from installing the software and opening files to working with Word, Excel, PowerPoint, and Outlook-and beyond. Plus, you'll discover how to manage files, share content and collaborate online through social media, and find help when you need it. Two things a

  8. Design of a digital PAD based on I/Q demodulation principle

    International Nuclear Information System (INIS)

    Geng Zheqiao; Cui Yanyan; Hou Mi; Pei Guoxi

    2005-01-01

    Conventional analog I/Q demodulator suffers from phase and amplitude imbalance and DC offset, which cause big error into the measurement. A digital PAD is designed. Based on I/Q demodulation principle, using digital algorithms, such as digital filter and Hilbert transform, the conventional measurement error can basically be removed. Measuremental results show that the digital PAD has a maximum phase error of ±0.5 degree and a resolution of 0.2 degree. Its temperature coefficient is -0.1 degree/degree C. Its dynamic ranges for phase-measurement and amplitude-measurement are -1825 dBm and -2020 dBm, respectively. The digital PAD can meet the need of the BEPC II phasing system. (authors)

  9. Examining Teachers' Use of iPads: Comfort Level, Perception, and Use

    Science.gov (United States)

    Liu, Min; Navarrete, Cesar C.; Scordino, Robert; Kang, Jina; Ko, Yujung; Lim, Mihyun

    2016-01-01

    While there is evidence of the growing popularity of iPads and other tablets in K-12 education, little is understood about how teachers use these devices in their instruction. This study examines 342 teachers' comfort level with and perception toward iPad use and any changes that occurred over the implementation year. Using a mixed-methods design,…

  10. Rancang Bangun Modul PAD (Packet Assembler Dissassembler Menggunakan AX.25 pada Sistem Komunikasi ITS-SAT

    Directory of Open Access Journals (Sweden)

    Pasang Arung Padang

    2013-09-01

    Full Text Available ITS-Sat merupakan jenis satelit piko yang saat ini sedang dikembangkan di Institut Teknologi Sepuluh Nopember. ITS-Sat membutuhkan suatu protokol komunikasi yang mengatur tata cara komunikasi satelit. Protokol AX.25 merupakan protokol komunikasi yang digunakan dalam sistem komunikasi ITS-Sat. Protokol ini berada pada layer data link dalam model OSI Layer. Protokol ini dapat membangun dan memutuskan link serta melakukan pengiriman data. Protokol AX.25 menggabungkan data-data field menjadi suatu frame. Makalah ini mengimplementasikan protokol AX.25 ke dalam modul PAD (Packet Assembler Dissassembler. Protokol AX.25 diimplementasikan ke dalam mikrokontroler yang merupakan otak dari modul PAD dengan menggunakan bahasa pemograman. Modul PAD berfungsi untuk mengkapsulasi data tiap field menjadi sebuah frame AX.25 sebelum dikirim dan kemudian frame AX.25 yang diterima dienkapsulasi kembali menjadi data field. Modul PAD yang dibuat dapat mengirim dan menerima data teks sebanyak 500 karakter. Hasil pengujian menunjukan bahwa modul PAD yang dibuat mampu melakukan komunikasi antar modul PAD dengan baik.

  11. Tribological properties of nonasbestos brake pad material by using coconut fiber

    Science.gov (United States)

    Craciun, A. L.; Pinca-Bretotean, C.; Utu, D.; Josan, A.

    2017-01-01

    In automotive industry, the brake system is influenced by a large number of variables including geometry of components, materials of brakes, components interaction and many operating condition. Organic fiber reinforced metallic friction composites are increasingly being used in automotive brake shoes, disc and pads, linings, blocks, clutch facings, primarily because of awareness of health hazards of asbestos. Current trend in the research field of automotive industry is to utilization of different wastes as a source of raw materials for composite materials. This will provide more economical benefit and also environmental preservation by utilize the waste of natural fibre In this paper it has performed a tribological study to determine the characteristics of the friction product by using coconut natural fibred reinforced in aluminium composite. In this sense, two different laboratory formulation were prepared with 5% and 10% coconut fibre and other constitutes like binder, friction modifiers, abrasive material and solid lubrificant using powder mettallurgy. These dnew materials for brake pads are tested for tribological behaviour in a standard pin on disc tribometer. To know the wear behavior of composite materials will determine the parameters that characterize there tribological properties.

  12. Monte Carlo studies on Cathode Strip/Pad Chambers for the ALICE Di-Muon Arm

    Energy Technology Data Exchange (ETDEWEB)

    Wurzinger, R.; Le Bornec, Y.; Willis, N.

    1996-04-01

    A general overview about the properties of Cathode Strip and Pad Chambers is given. Position finding methods are discussed and compared within Monte Carlo studies. Noise contributions and their minimization are discussed. Pad chambers allow a two-dimensional readout with spatial resolution of {sigma} < 100 {mu}m in direction parallel to the anode wire. The resolution normal to the anode wire depends mainly on the wire spacing. Special attention is paid on the double-hit resolution capability of the pad chamber. An outlook is given on the possible utilisation of Cathode Pad Chambers in the Di-Muon Arm of the ALICE detector at LHC. (author). 44 refs.

  13. Development of a novel iPad-based laparoscopic trainer and comparison with a standard laparoscopic trainer for basic laparoscopic skills testing.

    Science.gov (United States)

    Yoon, Renai; Del Junco, Michael; Kaplan, Adam; Okhunov, Zhamshid; Bucur, Philip; Hofmann, Martin; Alipanah, Reza; McDougall, Elspeth M; Landman, Jaime

    2015-01-01

    We developed the iTrainer (iT) as a portable laparoscopic trainer, which incorporates the iPad tablet. We then compared the iT with a standard pelvic trainer (SPT) to assess surgical skills as well as its image quality, resolution, brightness, comfort, and overall performance. We designed and constructed the iT to be compatible with the Apple iPad 3 and standard laparoscopic instruments. Participants were assigned to perform the thread-the-loops task on both trainers and were prospectively randomized to start on either the iT or the SPT. Each participant was allowed a 2-minute warm-up before the 2-minute testing period. We scored participants using the product of skill quality (0-4 scale) and quantity of loops threaded (0-10 scale). Participants then rated each trainer on image quality, resolution, brightness, comfort, and overall performance on a 5-point Likert scale. A total of 45 subjects including 10 undergraduates, 10 medical students, 10 general surgery and urology residents, and 15 experts (fellows and attending surgeons) participated in this study. There was no significant difference between thread-the-loops task scores completed on the iT when compared with the SPT for all groups tested (p > 0.05) with the exception of the medical student group, who performed better on the SPT (p < 0.05). On evaluation of each trainer, participants rated the iT as having superior image quality and resolution when compared with the SPT (p < 0.05) but rated the SPT higher in overall performance (p < 0.05). Brightness and comfort were rated similarly for both trainers. We have demonstrated face validity and criterion validity for the thread-the-loops task on the iT. The iT rated superior in image quality and resolution but inferior in overall performance compared with the SPT. The iT provides trainees a unique advantage over SPT as an additional resource to laparoscopic training as it is inexpensive, portable, and can be readily available for training. Copyright © 2014

  14. A Correlational Study of iPad Efficacy and 21st Century Teaching among Elementary School Teachers

    Science.gov (United States)

    Shultz, Christopher F.

    2017-01-01

    This study was a longitudinal correlational study that applied the quantitative methodology of bi-variate correlation as well as a paired-samples "t"-test to the data. The purpose was to study the nature of the relationship between iPad efficacy, 21st century teaching, teacher efficacy, and teacher characteristics. The study also…

  15. Inflammatory and metabolic alterations of Kager's fat pad in chronic achilles tendinopathy

    DEFF Research Database (Denmark)

    Pingel, Jessica; Petersen, Marie Christine Helby; Fredberg, Ulrich

    2015-01-01

    Kager's fat pad and its surrounding structures during movement of the ankle, suggesting that Kager's fat pad may stabilize and protect the mechanical function of the ankle joint. AIM: The aim of this study was to characterize whether Achilles tendinopathy was accompanied by changes in expression...

  16. Development of a hadron blind detector using a finely segmented pad readout

    International Nuclear Information System (INIS)

    Kanno, Koki; Aoki, Kazuya; Aramaki, Yoki; En'yo, Hideto; Kawama, Daisuke; Komatsu, Yusuke; Masumoto, Shinichi; Nakai, Wataru; Obara, Yuki; Ozawa, Kyoichiro; Sekimoto, Michiko; Shibukawa, Takuya; Takahashi, Tomonori; Watanabe, Yosuke; Yokkaichi, Satoshi

    2016-01-01

    We constructed a hadron blind detector (HBD) using a finely segmented pad readout. The finely segmented pad readout enabled us to adopt an advanced particle identification method which applies a threshold to the number of pad hits in addition to the total amount of collected charge. The responses of the detector to electrons and pions were evaluated using a negatively charged secondary beam at 1.0 GeV/c containing 20% electrons at the J-PARC K1.1BR beam line. We observed 7.3 photoelectrons per incident electron. Using the advanced particle identification method, an electron detection efficiency of 83% was achieved with a pion rejection factor of 120. The method improved the pion rejection by approximately a factor of five, compared to the one which just applies a threshold to the amount of collected charge. The newly introduced finely segmented pad readout was found to be effective in rejecting pions.

  17. Development of a hadron blind detector using a finely segmented pad readout

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, Koki, E-mail: kkanno@post.kek.jp [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); RIKEN Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Aoki, Kazuya [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Aramaki, Yoki; En' yo, Hideto; Kawama, Daisuke [RIKEN Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Komatsu, Yusuke; Masumoto, Shinichi [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Nakai, Wataru [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); RIKEN Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Obara, Yuki [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ozawa, Kyoichiro; Sekimoto, Michiko [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Shibukawa, Takuya [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Takahashi, Tomonori [Research Center for Nuclear Physics (RCNP), Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Watanabe, Yosuke [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Yokkaichi, Satoshi [RIKEN Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)

    2016-05-21

    We constructed a hadron blind detector (HBD) using a finely segmented pad readout. The finely segmented pad readout enabled us to adopt an advanced particle identification method which applies a threshold to the number of pad hits in addition to the total amount of collected charge. The responses of the detector to electrons and pions were evaluated using a negatively charged secondary beam at 1.0 GeV/c containing 20% electrons at the J-PARC K1.1BR beam line. We observed 7.3 photoelectrons per incident electron. Using the advanced particle identification method, an electron detection efficiency of 83% was achieved with a pion rejection factor of 120. The method improved the pion rejection by approximately a factor of five, compared to the one which just applies a threshold to the amount of collected charge. The newly introduced finely segmented pad readout was found to be effective in rejecting pions.

  18. [Response and prognosis of patients with multiple myeloma induced by PAD/TAD].

    Science.gov (United States)

    Zeng, Tianmei; He, Haiyan; Shi, Haotian; Xi, Hao; Du, Juan; Zhang, Chunyang; Jiang, Hua; Fu, Weijun; Zhou, Fan; Hou, Jian

    2015-03-17

    To evaluate the impact of cytogenetic grouping and autologous stem cell transplantation on the prognosis of patients with multiple myeloma (MM) induced by PAD (velcade+epirubicin+dexamethasone) and TAD (thalidomide+epirubicin+dexamethasone). A total of 191 patients with a definite diagnosis of MM were enrolled from May 2008 to December 2013 into this prospective study. They were non-randomly induced by PAD (n = 132) or TAD (n = 59) plus autologous stem cell transplantation or chemotherapy. Response and survival rates were also analyzed between two groups. The overall response rates of PAD and TAD groups were 84.4% (108/128) and 69.5% (41/59) (P = 0.011) respectively. The very good partial remission (VGPR) rates were 70.3% (90/128) and 32.2% (19/59) (P TAD. After PAD induction, cytogenetic grouping may further distinguish the prognosis of MM patients. For FISH high-risk patients, their PFS is prolonged by autologous stem cell transplantation.

  19. Expectations of iPad use in an internal medicine residency program: is it worth the "hype"?

    Science.gov (United States)

    Luo, Nancy; Chapman, Christopher G; Patel, Bhakti K; Woodruff, James N; Arora, Vineet M

    2013-05-08

    While early reports highlight the benefits of tablet computing in hospitals, introducing any new technology can result in inflated expectations. The aim of the study is to compare anticipated expectations of Apple iPad use and perceptions after deployment among residents. 115 internal medicine residents received Apple iPads in October 2010. Residents completed matched surveys on anticipated usage and perceptions after distribution 1 month prior and 4 months after deployment. In total, 99% (114/115) of residents responded. Prior to deployment, most residents believed that the iPad would improve patient care and efficiency on the wards; however, fewer residents "strongly agreed" after deployment (34% vs 15% for patient care, PApple iOS product owners were also more likely to use the iPad in key areas. Overall, 84% of residents thought the iPad was a good investment for the residency program, and over half of residents (58%) reported that patients commented on the iPad in a positive way. While the use of tablets such as the iPad by residents is generally well received, high initial expectations highlight the danger of implementing new technologies. Education on the realistic expectations of iPad benefits may be warranted.

  20. Analisis Penerimaan PAD Pada Dinas Perikanan dan Peternakan Kabupaten Tebo

    Directory of Open Access Journals (Sweden)

    Eko Purnarianto

    2016-06-01

    Full Text Available Abstract. This study aims to analyze potential, efficiency, effectivity and contribution of PAD admission at Department of Fishery and Animal Husbandry in Tebo Regencyincluding the strategy establishment to increase its revenue.The analysis used is a potential formula, efficiency ratio, effectivity ratio, contributions ratio and SWOT analysis.The results shows that the potential revenue of retribution slaughterhouse (RPH, the potential sales of livestock, and potential sales fishery product are beyond the current target. The efficiency level of retribution slaughterhouse (RPH and sales of fishery product is poor, but the sales of livestock is very efficient. Effectivity level of livestock and fishery product sales are low, whileretribution slaughterhouses(RPH is not effective regarded to its potential  but in the contrary for its target. Contribution of PAD admission of Fishery and Animal Husbandry Department is very low regarded Tebo Regency PAD. The result of SWOT analysis of retribution slaughter house (RPH admission using WO (Weakness-Opportunity strategy, livestock sales using SO (Strength-Oppurtunity strategy, and fishery product sales using ST (strength-threat strategy. Keywords: Retribution SlaughterHouse (RPH, Sales of Fishery, Livestock Sales, SWOT Analysis   Abstrak. Penelitian ini bertujuan untuk menganalisis potensi, efisiensi, efektivitas dan kontribusi penerimaan PAD pada Dinas Perikanan dan Peternakan Kabupaten Teboserta menetapkan strategi untuk peningkatan penerimaan PAD. Analisis yang digunakan adalah rumus potensi, rasio efisiensi, rasio efektivitas, rasio kontribusi dan analisis SWOT.Hasil penelitian menunjukkan bahwa potensi penerimaan retribusi rumah potong hewan (RPH, potensi penjualan hasil peternakan, potensi  penjualan hasil perikanan lebih besar dari target yang telah ditetapkan. Tingkat efisiensi retribusi RPH dan penjualan hasil perikanan tidak efisien, penjualan hasil peternakan sangat efisien. Tingkat

  1. iPad: Semantic annotation and markup of radiological images.

    Science.gov (United States)

    Rubin, Daniel L; Rodriguez, Cesar; Shah, Priyanka; Beaulieu, Chris

    2008-11-06

    Radiological images contain a wealth of information,such as anatomy and pathology, which is often not explicit and computationally accessible. Information schemes are being developed to describe the semantic content of images, but such schemes can be unwieldy to operationalize because there are few tools to enable users to capture structured information easily as part of the routine research workflow. We have created iPad, an open source tool enabling researchers and clinicians to create semantic annotations on radiological images. iPad hides the complexity of the underlying image annotation information model from users, permitting them to describe images and image regions using a graphical interface that maps their descriptions to structured ontologies semi-automatically. Image annotations are saved in a variety of formats,enabling interoperability among medical records systems, image archives in hospitals, and the Semantic Web. Tools such as iPad can help reduce the burden of collecting structured information from images, and it could ultimately enable researchers and physicians to exploit images on a very large scale and glean the biological and physiological significance of image content.

  2. New Encryption Scheme of One-Time Pad Based on KDC

    Science.gov (United States)

    Xie, Xin; Chen, Honglei; Wu, Ying; Zhang, Heng; Wu, Peng

    As more and more leakage incidents come up, traditional encryption system has not adapted to the complex and volatile network environment, so, there should be a new encryption system that can protect information security very well, this is the starting point of this paper. Based on DES and RSA encryption system, this paper proposes a new scheme of one time pad, which really achieves "One-time pad" and provides information security a new and more reliable encryption method.

  3. iPad-presented social stories for young children with autism.

    Science.gov (United States)

    Vandermeer, Julianne; Beamish, Wendi; Milford, Todd; Lang, Wayne

    2015-04-01

    This study investigated the effectiveness of iPad-presented social stories in increasing the on-task behaviour of three young children with autism. A single-subject with multiple baseline across participants design was employed with three 4-year-old children to assess intervention effectiveness during structured table top activities. Observational data were digitally recorded, scored, graphed, and interpreted using 10-second interval measures over 5-min periods across baseline, intervention, and withdrawal phases. The combination of the social story together with the iPad proved to be an effective intervention for one of the three child participants. These findings confirm that the intervention may be effective with some children, but not others. Overall, this study builds on existing research that supports social stories as a promising practice. Further research into the use of iPad-presented social stories, particularly for children of varying ages, abilities, and learning styles is recommended.

  4. Reversible adhesion switching of porous fibrillar adhesive pads by humidity.

    Science.gov (United States)

    Xue, Longjian; Kovalev, Alexander; Dening, Kirstin; Eichler-Volf, Anna; Eickmeier, Henning; Haase, Markus; Enke, Dirk; Steinhart, Martin; Gorb, Stanislav N

    2013-01-01

    We report reversible adhesion switching on porous fibrillar polystyrene-block-poly(2-vinyl pyridine) (PS-b-P2VP) adhesive pads by humidity changes. Adhesion at a relative humidity of 90% was more than nine times higher than at a relative humidity of 2%. On nonporous fibrillar adhesive pads of the same material, adhesion increased only by a factor of ~3.3. The switching performance remained unchanged in at least 10 successive high/low humidity cycles. Main origin of enhanced adhesion at high humidity is the humidity-induced decrease in the elastic modulus of the polar component P2VP rather than capillary force. The presence of spongelike continuous internal pore systems with walls consisting of P2VP significantly leveraged this effect. Fibrillar adhesive pads on which adhesion is switchable by humidity changes may be used for preconcentration of airborne particulates, pollutants, and germs combined with triggered surface cleaning.

  5. Padé approximations and diophantine geometry.

    Science.gov (United States)

    Chudnovsky, D V; Chudnovsky, G V

    1985-04-01

    Using methods of Padé approximations we prove a converse to Eisenstein's theorem on the boundedness of denominators of coefficients in the expansion of an algebraic function, for classes of functions, parametrized by meromorphic functions. This result is applied to the Tate conjecture on the effective description of isogenies for elliptic curves.

  6. A fast integrated readout system for a cathode pad photon detector

    Energy Technology Data Exchange (ETDEWEB)

    French, M. (Rutherford Appleton Lab., Chilton (United Kingdom)); Lovell, M. (Rutherford Appleton Lab., Chilton (United Kingdom)); Chesi, E. (CERN, ECP Div., Geneva (Switzerland)); Racz, A. (CERN, ECP Div., Geneva (Switzerland)); Seguinot, J. (Coll. de France, Paris (France)); Ypsilantis, T. (Coll. de France, Paris (France)); Arnold, R. (CRN, Louis Pasteur Univ., Strasbourg (France)); Guyonnet, J.L. (CRN, Louis Pasteur Univ., Strasbourg (France)); Egger, J. (Paul Scherrer Inst., Villigen (Switzerland)); Gabathuler, K. (Paul Scherrer Inst., Villigen (Switzerland))

    1994-04-01

    A fast integrated electronic chain is presented to read out the cathode pad array of a multiwire photon detector for a fast RICH counter. Two VLSI circuits have been designed and produced. An analog eight channel, low noise, fast, bipolar, current preamplifier and discriminator chip serves as front-end electronics. It has an rms equivalent noise current of 10 nA (2000 e[sup -]), 50 MHz bandwidth with 10 mW of power consumption per channel. Two analogue chips are coupled to a digital 16 channels CMOS readout chip, operating at 20 MHz, that provides a pipelined delay of 1.3 [mu]s and zero suppression with a power consumption of about 6 mW per channel. Readout of a 4000 pad sector requires 3-4 [mu]s depending on the number of hit pads. The full RICH counter is made up of many of such sectors (the prototype has three fully equipped sectors), read out in parallel. The minimum time to separate successive hits on the same pad is about 70 ns. The time skew of the full chain is about 15 ns. (orig.)

  7. How does the canine paw pad attenuate ground impacts? A multi-layer cushion system

    Directory of Open Access Journals (Sweden)

    Huaibin Miao

    2017-12-01

    Full Text Available Macroscopic mechanical properties of digitigrade paw pads, such as non-linear elastic and variable stiffness, have been investigated in previous studies; however, little is known about the micro-scale structural characteristics of digitigrade paw pads, or the relationship between these characteristics and the exceptional cushioning of the pads. The digitigrade paw pad consists of a multi-layered structure, which is mainly comprised of a stratified epithelium layer, a dermis layer and a subcutaneous layer. The stratified epithelium layer and dermal papillae constitute the epidermis layer. Finite element analyses were carried out and showed that the epidermis layer effectively attenuated the ground impact across impact velocities of 0.05–0.4 m/s, and that the von Mises stresses were uniformly distributed in this layer. The dermis layer encompassing the subcutaneous layer can be viewed as a hydrostatic system, which can store, release and dissipate impact energy. All three layers in the paw pad work as a whole to meet the biomechanical requirements of animal locomotion. These findings provide insights into the biomechanical functioning of digitigrade paw pads and could be used to facilitate bio-inspired, ground-contacting component development for robots and machines, as well as contribute to footwear design.

  8. How does the canine paw pad attenuate ground impacts? A multi-layer cushion system.

    Science.gov (United States)

    Miao, Huaibin; Fu, Jun; Qian, Zhihui; Ren, Luquan; Ren, Lei

    2017-12-15

    Macroscopic mechanical properties of digitigrade paw pads, such as non-linear elastic and variable stiffness, have been investigated in previous studies; however, little is known about the micro-scale structural characteristics of digitigrade paw pads, or the relationship between these characteristics and the exceptional cushioning of the pads. The digitigrade paw pad consists of a multi-layered structure, which is mainly comprised of a stratified epithelium layer, a dermis layer and a subcutaneous layer. The stratified epithelium layer and dermal papillae constitute the epidermis layer. Finite element analyses were carried out and showed that the epidermis layer effectively attenuated the ground impact across impact velocities of 0.05-0.4 m/s, and that the von Mises stresses were uniformly distributed in this layer. The dermis layer encompassing the subcutaneous layer can be viewed as a hydrostatic system, which can store, release and dissipate impact energy. All three layers in the paw pad work as a whole to meet the biomechanical requirements of animal locomotion. These findings provide insights into the biomechanical functioning of digitigrade paw pads and could be used to facilitate bio-inspired, ground-contacting component development for robots and machines, as well as contribute to footwear design. © 2017. Published by The Company of Biologists Ltd.

  9. iTE: Student Teachers Using iPad on a Second Level Initial Teacher Education Programme

    Science.gov (United States)

    Mac Mahon, Brendan; Grádaigh, Seán Ó.; Ghuidhir, Sinéad Ní

    2016-01-01

    Research on the use of iPad in initial teacher education is limited. This paper outlines a study to examine how the professional learning and pedagogical knowledge development of student teachers could be supported following 1:1 iPad deployment on a second-level initial teacher education programme in Ireland. Findings show that iPad can be…

  10. Comparison of Models for the Steady-State Analysis of Tilting-Pad Thrust Bearings

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar

    2005-01-01

    Prediction of the minimum oil film thickness and the maximum temperature on the surface of the bearing pad is crucial in the design and dimensioning of bearings. Friction loss, oil bath temperature and pad deflection are other parameters of interest. Depending on the desired information a numerical...... for the groove between pads and the oil bath temperature from energy equilibrium for the entire bearing. The main theoretical contribution of this paper is the elaboration and comparison of 7 different mathematical models of increasing complexity. The results are compared to experimental data for steady......-state operation of a 228 mm outer diameter bearing. It is found that for the given bearing a two dimensional model is sufficient to estimate the minimum oil film thickness and the maximum temperature on the pad surface. Three dimensional modelling does not improve the quality of the results....

  11. Introduction to PAC/PAD

    International Nuclear Information System (INIS)

    Mahnke, H.E.

    1988-01-01

    Both methods, Perturbed Angular Correlation (PAC) utilizing radioactive probes and Perturbed Angular Distribution (PAD) following nuclear reactions measure hyperfine interaction parameters and allow to study magnetism on a rather local scale. While both techniques are based on the same theory the underlying concepts are quite different. Examples on local moments, influence of the nearest-neighbor to the magnetic field in ferromagnets, knight shift in nonmagnetic materials, and magnetism in high-temperature superconductors and related oxides illustrate the recent developments within the methods and the improvements in their sensitivity and resolution. (orig.)

  12. Avaliação da presença de Staphylococcus aureus nos leitos do Centro de Terapia Intensiva do Hospital Escola da Faculdade de Medicina do Triângulo Mineiro, em relação à posição no colchão antes e após a limpeza Evaluation of presence of Staphylococcus aureus on the beds of Hospital Escola's Intensive Care Unit, concerning the position on the mattress, before and after cleaning

    Directory of Open Access Journals (Sweden)

    Guilhermo Justino Mundim

    2003-12-01

    Full Text Available Através de meios de cultura, foi pesquisada a posição de colônias de Staphylococcus aureus em colchões, visando avaliar a eficácia do procedimento de limpeza e desinfecção dos leitos do Hospital Escola da Faculdade de Medicina do Triângulo Mineiro (Uberaba. Foram analisadas amostras de 50 colchões no período de 22 de outubro de 2000 a 16 de janeiro de 2001. As amostras foram coletadas e semeadas, pela técnica de esgotamento, em dois meios de cultivo (ágar sangue e manitol com posterior realização de provas de catalase e coagulase . Na análise estatística, foram utilizados os testes não paramétricos Mann-Whitney, Kruswkal- Wallis e Wilcoxon Matched Pairs Test com nível de significância p 0,05. Os resultados apontam e alertam para falhas no procedimento de limpeza e desinfecção dos leitos hospitalares por nós estudados.By means of culture medium, it was researched the position of the colony of Staphylococcus aureus on the mattress, to evaluate the efficciuoness of the methods of cleaning and disinfection of the river bed in the Faculdade de Medicina do Triângulo Mineiro's School Hospital (Uberaba. It were evaluated fifty mattresses on the period of October 22th (2000 to January 16th (2001. The samples were collected and grown, the exhaustion techinique draining, on two different nutrient bases (blood agar and mannitol salt agar followed by catalase and coagulase tests. For the statistical analysis, were used non-parametrics tests Mann-Whitney, Kruskal-Wallis, Wilcoxon Matched Pairs Test with significance level p < 0,05 were used. Six hundred dishes of culture medium have been used. There was growing in 94 (15,6%, being 82 (87,2% before and 12 (12,8% after cleaning and disinfection. Concerning the position on the bed, the samples obtained from mannitol salt agar medium showed significant retention on the lower position of bed. The results alert to flaws in the procedure for cleaning and disinfection from the mattresses

  13. Effects of PCB Pad Metal Finishes on the Cu-Pillar/Sn-Ag Micro Bump Joint Reliability of Chip-on-Board (COB) Assembly

    Science.gov (United States)

    Kim, Youngsoon; Lee, Seyong; Shin, Ji-won; Paik, Kyung-Wook

    2016-06-01

    While solder bumps have been used as the bump structure to form the interconnection during the last few decades, the continuing scaling down of devices has led to a change in the bump structure to Cu-pillar/Sn-Ag micro-bumps. Cu-pillar/Sn-Ag micro-bump interconnections differ from conventional solder bump interconnections in terms of their assembly processing and reliability. A thermo-compression bonding method with pre-applied b-stage non-conductive films has been adopted to form solder joints between Cu pillar/Sn-Ag micro bumps and printed circuit board vehicles, using various pad metal finishes. As a result, various interfacial inter-metallic compounds (IMCs) reactions and stress concentrations occur at the Cu pillar/Sn-Ag micro bumps joints. Therefore, it is necessary to investigate the influence of pad metal finishes on the structural reliability of fine pitch Cu pillar/Sn-Ag micro bumps flip chip packaging. In this study, four different pad surface finishes (Thin Ni ENEPIG, OSP, ENEPIG, ENIG) were evaluated in terms of their interconnection reliability by thermal cycle (T/C) test up to 2000 cycles at temperatures ranging from -55°C to 125°C and high-temperature storage test up to 1000 h at 150°C. The contact resistances of the Cu pillar/Sn-Ag micro bump showed significant differences after the T/C reliability test in the following order: thin Ni ENEPIG > OSP > ENEPIG where the thin Ni ENEPIG pad metal finish provided the best Cu pillar/Sn-Ag micro bump interconnection in terms of bump joint reliability. Various IMCs formed between the bump joint areas can account for the main failure mechanism.

  14. Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.

    Science.gov (United States)

    Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol

    2015-12-15

    The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E

  15. Exploring integral controllers in actively-lubricated tilting-pad journal bearings

    DEFF Research Database (Denmark)

    Salazar, Jorge Andrés González; Santos, Ilmar

    2015-01-01

    investigation of integral controllers for feedback-controlled lubrication with the aim of: a) presetting the static journal center and consequently exploring the changes of bearing dynamic properties; b) obtaining an integral controller capable of re-positioning the static journal eccentricity for matching......Active tilting-pad journal bearings with radial oil injection combine good stability properties of conventional tilting-pad journal bearings with the capability of improving their dynamic properties even more by control techniques. The main contribution of this work is the experimental...

  16. Crystal structures of two transcriptional regulators from Bacillus cereus define the conserved structural features of a PadR subfamily.

    Directory of Open Access Journals (Sweden)

    Guntur Fibriansah

    Full Text Available PadR-like transcriptional regulators form a structurally-related family of proteins that control the expression of genes associated with detoxification, virulence and multi-drug resistance in bacteria. Only a few members of this family have been studied by genetic, biochemical and biophysical methods, and their structure/function relationships are still largely undefined. Here, we report the crystal structures of two PadR-like proteins from Bacillus cereus, which we named bcPadR1 and bcPadR2 (products of gene loci BC4206 and BCE3449 in strains ATCC 14579 and ATCC 10987, respectively. BC4206, together with its neighboring gene BC4207, was previously shown to become significantly upregulated in presence of the bacteriocin AS-48. DNA mobility shift assays reveal that bcPadR1 binds to a 250 bp intergenic region containing the putative BC4206-BC4207 promoter sequence, while in-situ expression of bcPadR1 decreases bacteriocin tolerance, together suggesting a role for bcPadR1 as repressor of BC4206-BC4207 transcription. The function of bcPadR2 (48% identical in sequence to bcPadR1 is unknown, but the location of its gene just upstream from genes encoding a putative antibiotic ABC efflux pump, suggests a role in regulating antibiotic resistance. The bcPadR proteins are structurally similar to LmrR, a PadR-like transcription regulator in Lactococcus lactis that controls expression of a multidrug ABC transporter via a mechanism of multidrug binding and induction. Together these proteins define a subfamily of conserved, relatively small PadR proteins characterized by a single C-terminal helix for dimerization. Unlike LmrR, bcPadR1 and bcPadR2 lack a central pore for ligand binding, making it unclear whether the transcriptional regulatory roles of bcPadR1 and bcPadR2 involve direct ligand recognition and induction.

  17. Engaging Primary School Students in Mathematics: Can iPads Make a Difference?

    Science.gov (United States)

    Hilton, Annette

    2018-01-01

    Research on the impact of the integration of technologies such as iPads on primary students' attitudes and engagement in mathematics is limited. Further, there have been claims that teachers' pedagogical choices can strongly influence the effectiveness of iPads for engaging students in mathematics. This paper presents an investigation of the…

  18. Establishment of Approximate Analytical Model of Oil Film Force for Finite Length Tilting Pad Journal Bearings

    Directory of Open Access Journals (Sweden)

    Yongliang Wang

    2015-01-01

    Full Text Available Tilting pad bearings offer unique dynamic stability enabling successful deployment of high-speed rotating machinery. The model of dynamic stiffness, damping, and added mass coefficients is often used for rotordynamic analyses, and this method does not suffice to describe the dynamic behaviour due to the nonlinear effects of oil film force under larger shaft vibration or vertical rotor conditions. The objective of this paper is to present a nonlinear oil force model for finite length tilting pad journal bearings. An approximate analytic oil film force model was established by analysing the dynamic characteristic of oil film of a single pad journal bearing using variable separation method under the dynamic π oil film boundary condition. And an oil film force model of a four-tilting-pad journal bearing was established by using the pad assembly technique and considering pad tilting angle. The validity of the model established was proved by analyzing the distribution of oil film pressure and the locus of journal centre for tilting pad journal bearings and by comparing the model established in this paper with the model established using finite difference method.

  19. Foam pad of appropriate thickness can improve diagnostic value of foam posturography in detecting postural instability.

    Science.gov (United States)

    Liu, Bo; Leng, Yangming; Zhou, Renhong; Liu, Jingjing; Liu, Dongdong; Liu, Jia; Zhang, Su-Lin; Kong, Wei-Jia

    2018-04-01

    The present study investigated the effect of foam thickness on postural stability in patients with unilateral vestibular hypofunction (UVH) during foam posturography. Static and foam posturography were performed in 33 patients (UVH group) and 30 healthy subjects (control group) with eyes open (EO) and closed (EC) on firm surface and on 1-5 foam pad(s). Sway velocity (SV) of center of pressure, standing time before falling (STBF) and falls reaction were recorded and analyzed. (1) SVs had an increasing tendency in both groups as the foam pads were added under EO and EC conditions. (2) STBFs, only in UVH group with EC, decreased with foam thickness increasing. (3) Significant differences in SV were found between the control and UVH group with EO (except for standing on firm surface, on 1 and 2 foam pad(s)) and with EC (all surface conditions). (4) Receiver operating characteristic curve analysis showed that the SV could better reflect the difference in postural stability between the two groups while standing on the 4 foam pads with EC. Our study showed that diagnostic value of foam posturography in detecting postural instability might be enhanced by using foam pad of right thickness.

  20. Cask crush pad analysis using detailed and simplified analysis methods

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Hawkes, B.D.

    1997-01-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of a hypothetically dropped spent nuclear fuel shipping cask into a 44-ft. deep cask unloading pool at the Fluorinel and Storage Facility (FAST). This facility, located at the Idaho Chemical Processing Plant (ICPP) at the Idaho national Engineering and Environmental Laboratory (INEEL), is a US Department of Energy site. The basis for this study is an analysis by Uldrich and Hawkes. The purpose of this analysis was to evaluate various hypothetical cask drop orientations to ensure that the crush pad design was adequate and the cask deceleration at impact was less than 100 g. It is demonstrated herein that a large spent fuel shipping cask, when dropped onto a foam crush pad, can be analyzed by either hand methods or by sophisticated dynamic finite element analysis using computer codes such as ABAQUS. Results from the two methods are compared to evaluate accuracy of the simplified hand analysis approach

  1. Launch Pad Escape System Design (Human Spaceflight)

    Science.gov (United States)

    Maloney, Kelli

    2011-01-01

    A launch pad escape system for human spaceflight is one of those things that everyone hopes they will never need but is critical for every manned space program. Since men were first put into space in the early 1960s, the need for such an Emergency Escape System (EES) has become apparent. The National Aeronautics and Space Administration (NASA) has made use of various types of these EESs over the past 50 years. Early programs, like Mercury and Gemini, did not have an official launch pad escape system. Rather, they relied on a Launch Escape System (LES) of a separate solid rocket motor attached to the manned capsule that could pull the astronauts to safety in the event of an emergency. This could only occur after hatch closure at the launch pad or during the first stage of flight. A version of a LES, now called a Launch Abort System (LAS) is still used today for all manned capsule type launch vehicles. However, this system is very limited in that it can only be used after hatch closure and it is for flight crew only. In addition, the forces necessary for the LES/LAS to get the capsule away from a rocket during the first stage of flight are quite high and can cause injury to the crew. These shortcomings led to the development of a ground based EES for the flight crew and ground support personnel as well. This way, a much less dangerous mode of egress is available for any flight or ground personnel up to a few seconds before launch. The early EESs were fairly simple, gravity-powered systems to use when thing's go bad. And things can go bad very quickly and catastrophically when dealing with a flight vehicle fueled with millions of pounds of hazardous propellant. With this in mind, early EES designers saw such a passive/unpowered system as a must for last minute escapes. This and other design requirements had to be derived for an EES, and this section will take a look at the safety design requirements had to be derived for an EES, and this section will take a look at

  2. Eye/Head Tracking Technology to Improve HCI with iPad Applications

    Directory of Open Access Journals (Sweden)

    Asier Lopez-Basterretxea

    2015-01-01

    Full Text Available In order to improve human computer interaction (HCI for people with special needs, this paper presents an alternative form of interaction, which uses the iPad’s front camera and eye/head tracking technology. With this functional nature/capability operating in the background, the user can control already developed or new applications for the iPad by moving their eyes and/or head. There are many techniques, which are currently used to detect facial features, such as eyes or even the face itself. Open source bookstores exist for such purpose, such as OpenCV, which enable very reliable and accurate detection algorithms to be applied, such as Haar Cascade using very high-level programming. All processing is undertaken in real time, and it is therefore important to pay close attention to the use of limited resources (processing capacity of devices, such as the iPad. The system was validated in tests involving 22 users of different ages and characteristics (people with dark and light-colored eyes and with/without glasses. These tests are performed to assess user/device interaction and to ascertain whether it works properly. The system obtained an accuracy of between 60% and 100% in the three test exercises taken into consideration. The results showed that the Haar Cascade had a significant effect by detecting faces in 100% of cases, unlike eyes and the pupil where interference (light and shade evidenced less effectiveness. In addition to ascertaining the effectiveness of the system via these exercises, the demo application has also helped to show that user constraints need not affect the enjoyment and use of a particular type of technology. In short, the results obtained are encouraging and these systems may continue to be developed if extended and updated in the future.

  3. The iPad: tablet technology to support nursing and midwifery student learning: an evaluation in practice.

    Science.gov (United States)

    Brown, Janie; McCrorie, Pamela

    2015-03-01

    This research explored the impact of tablet technology, in the form of Apple iPads, on undergraduate nursing and midwifery students' learning outcomes. In simulated clinical learning environments, first-year nursing students (n = 30) accessed apps and reference materials on iPads. Third-year nursing students (n = 88) referred to clinical guidelines to aid their decision making when problem solving. First-year midwifery students (n = 25) filmed themselves undertaking a skill and then immediately played back the video file. A total of 45 students completed an online questionnaire that allowed for qualitative comments. Students reported finding the use of iPads easy and that iPads provided point-of-care access to resources, ensuring an evidence-based approach to clinical decision making. iPads reportedly improved student efficiency and time management, while improving their ability to provide patient education. Students who used iPads for the purpose of formative self-assessment appreciated the immediate feedback and opportunity to develop clinical skills.

  4. Solar panel assembly and support pad

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1980-10-07

    A solar panel assembly is described comprising at least one solar panel, support means for carrying said panel, and at least one support pad having a base plate, upstanding longitudinal sides, and spaced apart flange means for connection to said support means, said upstanding sides and opposed flange means defining an interior volume for receiving and holding weighting material.

  5. Relationships between rodent white adipose fat pads and human white adipose fat depots

    Directory of Open Access Journals (Sweden)

    Daniella E. Chusyd

    2016-04-01

    Full Text Available The objective of this review was to compare and contrast the physiological and metabolic profiles of rodent white adipose fat pads with white adipose fat depots in humans. Human fat distribution and its metabolic consequences have received extensive attention, but much of what has been tested in translational research has relied heavily on rodents. Unfortunately, the validity of using rodent fat pads as a model of human adiposity has received less attention. There is a surprisingly lack of studies demonstrating an analogous relationship between rodent and human adiposity on obesity-related comorbidities. Therefore, we aimed to compare known similarities and disparities in terms of white adipose tissue development and distribution, sexual dimorphism, weight loss, adipokine secretion, and aging. While the literature supports the notion that many similarities exist between rodents and humans, notable differences emerge related to fat deposition and function of white adipose tissue. Thus, further research is warranted to more carefully define the strengths and limitations of rodent white adipose tissue as a model for humans, with a particular emphasis on comparable fat depots, such as mesenteric fat.

  6. Developing C# Apps for iPhone and iPad using MonoTouch

    CERN Document Server

    Costanich, Bryan

    2011-01-01

    Developing C# Applications for iPhone and iPad using MonoTouch shows you how to use your existing C# skills to write apps for the iPhone and iPad. Fortunately, there's MonoTouch, Novell's .NET library that allows C# developers to write C# code that executes in iOS. Furthermore, MonoTouch allows you to address all the unique functions of the iPhone, iPod Touch, and iPad. And the big plus: You needn't learn any Objective-C to master MonoTouch!. Former Microsoft engineer and published app-store developer Bryan Costanich shows you how to use the tools you already know to create native apps in iOS

  7. A multi-pad electrode based functional electrical stimulation system for restoration of grasp

    Directory of Open Access Journals (Sweden)

    Malešević Nebojša M

    2012-09-01

    Full Text Available Abstract Background Functional electrical stimulation (FES applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm. Methods The new FES system comprises an electrode composed of small pads that can be activated individually. This electrode allows the targeting of motoneurons that activate synergistic muscles and produce a functional movement. The new stimulation paradigm allows asynchronous activation of motoneurons and provides controlled spatial distribution of the electrical charge that is delivered to the motoneurons. We developed an automated technique for the determination of the preferred electrode based on a cost function that considers the required movement of the fingers and the stabilization of the wrist joint. The data used within the cost function come from a sensorized garment that is easy to implement and does not require calibration. The design of the system also includes the possibility for fine-tuning and adaptation with a manually controllable interface. Results The device was tested on three stroke patients. The results show that the multi-pad electrodes provide the desired level of selectivity and can be used for generating a functional grasp. The results also show that the procedure, when performed on a specific user, results in the preferred electrode configuration characteristics for that patient. The findings from this study are of importance for the application of transcutaneous stimulation in the clinical and home environments.

  8. Imaging findings of Hoffa's fat pad herniation

    Energy Technology Data Exchange (ETDEWEB)

    Chauvin, Nancy A.; Khwaja, Asef [The Children' s Hospital of Philadelphia, Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA (United States); Epelman, Monica [Nemours Children' s Hospital, Department of Medical Imaging, Orlando, FL (United States); Callahan, Michael J. [Harvard Medical School, Department of Radiology, Boston Children' s Hospital, Boston, MA (United States)

    2016-04-15

    We report the radiologic findings of herniation of Hoffa's fat pad through a defect in the lateral patellar retinaculum in young children who presented with painless masses visible by ultrasound (US) only with flexion of the knee. Six children, between the ages of 1-8 years, presented with an anterolateral knee mass that was not tender and was only seen and palpable with knee flexion. An US was performed in all patients, magnetic resonance imaging (MRI) in 2 patients and knee radiographs in 1 patient. US imaging displayed focal herniation of Hoffa's fat pad within the infrapatellar region through a defect of the lateral retinaculum, visible only during dynamic imaging when the knee was in flexion. MRI performed in knee extension did not demonstrate a mass; however, it revealed a focal defect in the lateral retinaculum in the region of the abnormality. Radiographs were normal. Focal herniation of Hoffa's fat pad is an uncommon cause of an anterolateral knee mass in young children. When a knee mass is only identified in flexion, focal fat herniation through a defect in the retinaculum should be suspected and a dynamic US should be performed. (orig.)

  9. Imaging findings of Hoffa's fat pad herniation

    International Nuclear Information System (INIS)

    Chauvin, Nancy A.; Khwaja, Asef; Epelman, Monica; Callahan, Michael J.

    2016-01-01

    We report the radiologic findings of herniation of Hoffa's fat pad through a defect in the lateral patellar retinaculum in young children who presented with painless masses visible by ultrasound (US) only with flexion of the knee. Six children, between the ages of 1-8 years, presented with an anterolateral knee mass that was not tender and was only seen and palpable with knee flexion. An US was performed in all patients, magnetic resonance imaging (MRI) in 2 patients and knee radiographs in 1 patient. US imaging displayed focal herniation of Hoffa's fat pad within the infrapatellar region through a defect of the lateral retinaculum, visible only during dynamic imaging when the knee was in flexion. MRI performed in knee extension did not demonstrate a mass; however, it revealed a focal defect in the lateral retinaculum in the region of the abnormality. Radiographs were normal. Focal herniation of Hoffa's fat pad is an uncommon cause of an anterolateral knee mass in young children. When a knee mass is only identified in flexion, focal fat herniation through a defect in the retinaculum should be suspected and a dynamic US should be performed. (orig.)

  10. 40 CFR 270.26 - Special part B information requirements for drip pads.

    Science.gov (United States)

    2010-07-01

    ... residuals. (14) A description of how each drip pad, including appurtenances for control of run-on and run..., detailed plans and an engineering report describing how the requirements of § 264.90(b)(2) of this chapter will be met. (c) Detailed plans and an engineering report describing how the drip pad is or will be...

  11. iPad Deployment in a Diverse Urban High School: A Formative Experiment

    Science.gov (United States)

    Frey, Nancy; Fisher, Douglas; Lapp, Diane

    2015-01-01

    We explore the use of iPads in a diverse urban high school and the ways in which teachers and students were supported to integrate these tools into their instruction. We provided 4 English teachers with 20 iPads with little or no professional development about how to integrate them into their instruction. Using a formative experiment design, we…

  12. iPads in K-12 Schools: A Grounded Theory Study of Value

    Science.gov (United States)

    Townsend, Mary Beth

    2017-01-01

    This qualitative grounded theory study investigated the value of iPads in K-12 schools when used in one-to-one ratios. The purpose of the study was to understand the perspectives of teachers using iPads in one-to-one ratios for teaching and learning in the classroom and administrators responsible for the implementation of these devices. The…

  13. Expectations of iPad Use in an Internal Medicine Residency Program: Is It Worth the “Hype”?

    Science.gov (United States)

    Luo, Nancy; Chapman, Christopher G; Patel, Bhakti K; Woodruff, James N

    2013-01-01

    Background While early reports highlight the benefits of tablet computing in hospitals, introducing any new technology can result in inflated expectations. Objective The aim of the study is to compare anticipated expectations of Apple iPad use and perceptions after deployment among residents. Methods 115 internal medicine residents received Apple iPads in October 2010. Residents completed matched surveys on anticipated usage and perceptions after distribution 1 month prior and 4 months after deployment. Results In total, 99% (114/115) of residents responded. Prior to deployment, most residents believed that the iPad would improve patient care and efficiency on the wards; however, fewer residents “strongly agreed” after deployment (34% vs 15% for patient care, PiPad for placing orders post call and during admission (71% vs 44% post call, P=.01, and 16% vs 0% admission, P=.04). Previous Apple iOS product owners were also more likely to use the iPad in key areas. Overall, 84% of residents thought the iPad was a good investment for the residency program, and over half of residents (58%) reported that patients commented on the iPad in a positive way. Conclusions While the use of tablets such as the iPad by residents is generally well received, high initial expectations highlight the danger of implementing new technologies. Education on the realistic expectations of iPad benefits may be warranted. PMID:23656727

  14. "I Have an iPad. Now What?" Using Mobile Devices in University Physical Education Programs

    Science.gov (United States)

    Rosenthal, Maura B.; Eliason, Susan K.

    2015-01-01

    In response to an iPad initiative at a mid-sized New England university, all faculty, junior and senior undergraduates, and graduate students were required to have iPads by the first day of class in the fall semester of 2013. Goals of the initiative focused on preparing future teachers to use the iPad as a teaching and learning tool so they could…

  15. Pad printing as a film forming technique for polymer solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Krebs, Frederik C. [Risoe National Laboratory for Sustainable Energy, Technical University of Denmark, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2009-04-15

    Pad printing as a technique for preparing the active layer in polymer solar cells is presented. The technique employs a silicone rubber stamp to pick up the motif from a gravure plate and transfer it to the substrate. The strengths and limitations of pad printing are discussed and polymer solar cells prepared by pad printing are presented. Devices were prepared on indium tin oxide substrates but in principle the entire photovoltaic device comprising front and back electrodes, barrier layers and active layer could be printed with no need for vacuum steps. The device geometry comprises a spin coated transparent zinc oxide front electrode, a pad printed active layer based on a bulk heterojunction of the thermocleavable polymer poly(3-(2-methylhexyloxycarbonyl)thiophene-co-thiopene) (P3MHOCT) and zinc oxide nanoparticles, spin coated PEDOT:PSS and finally a manually cast thermally cured silver paste back electrode. The P3MHOCT was converted to poly(3-carboxy-dithiophene) (P3CT) in situ by heating the film to 200 C for a brief period. The entire printing and device preparation was carried out in the ambient atmosphere and the devices obtained had a good stability in air during storage and operation. (author)

  16. Monolithic front-end ICs for interpolating cathode pad and strip detectors for GEM

    International Nuclear Information System (INIS)

    O'Connor, P.

    1993-05-01

    We are developing CMOS circuits for readout of interpolating cathode strip and pad chambers for the GEM experiment at the SSC. Because these detectors require position resolution of about 1% of the strip pitch, the electronic noise level must be less than 2000 electrons. Several test chips have been fabricated to demonstrate the feasibility of achieving the combination of low noise, speed, and wide dynamic range in CMOS. Results to date show satisfactory noise and linearity performance. Future development will concentrate on radiation-hardening the central tracker ASIC design, optimizing the shaper peaking time and noise contribution, providing more user-configurable output options, and packaging and test issues

  17. View and Manage Your Photos on the iPad

    CERN Document Server

    Biersdorfer, J

    2010-01-01

    One of the iPad's big pluses is its beautiful, high-resolution display. That makes it a perfect way to stroll down memory lane-from the comfort of your armchair. View and Manage Your Photos on the iPad: The Mini Missing Manual shows you how to import, organize, and enjoy your photos using clear, jargon-free explanations and step-by-step instructions. You'll learn to create slideshows complete with your own soundtrack and transitions, connect your tablet to a big-screen TV so you can gather the family around, turn your slab into a digital picture frame (a great idea when you recharge your 'Pa

  18. Best iPad Apps The Guide for Discriminating Downloaders

    CERN Document Server

    Meyers, Peter

    2010-01-01

    What really wows iPad fans is when their touchscreen does what's impossible on other gadgets: the finger-painting app that turns a cross-country flight into a moving art class, the mini music studio (two-dozen instruments strong, each with motion-induced warble effects), and the portable fireworks display that you sculpt by swiping. Problem is, with tens of thousands of apps available for your iPad, who knows what to download? You can try to sort through a gazillion customer reviews with a mix of 5- and 1-star ratings, but that's a head-hurting time-waster. The stakes are getting higher, too

  19. Cefazolin-containing poly(ε-caprolactone sponge pad to reduce pin tract infection rate in rabbits

    Directory of Open Access Journals (Sweden)

    Hirotaka Mutsuzaki

    2014-04-01

    Full Text Available In our previous study, a fibroblast growth factor-2 (FGF-2–apatite composite layer coated on titanium screws effectively prevented pin tract infection in rabbits because of enhanced wound healing; however, the FGF-2–apatite composite layers did not completely prevent pin tract infection. Thus, we recently developed a poly(ε-caprolactone (PCL sponge pad embedded with cefazolin sodium (+CEZ, which has a fast-acting bactericidal effect. The pad is placed on the skin around the screws. The purpose of this study was to determine the anti-infective efficacy of the +CEZ pad on the pin–skin interface of the FGF-2–apatite-coated titanium screws. The +CEZ pads were prepared by mixing PCL and CEZ in 1,4-dioxane, followed by freeze-drying and compaction. They were analyzed regarding their surface structure, in vitro CEZ release profile, and bactericidal activity. The FGF-2–apatite-coated screws were implanted percutaneously in bilateral rabbit proximal tibial metaphyses—with and without the +CEZ pad—for 4 weeks (n = 20. The + CEZ pads consisted of a porous matrix of PCL in which CEZ was embedded. The CEZ-release profile showed an initial burst on Day 1 and a sustained release lasting for 30 days. The +CEZ pad retained its bactericidal activity against Staphylococcus aureus after preincubation on an agar plate for 7 days. Based on visual inspection, the pin tract infection rate was successfully reduced from 72.2% to 15.0% with the +CEZ pad (p < 0.05, which reduced the bacterial count, especially S. aureus (p < 0.05. The histological inflammation rate of the soft tissues was also significantly lower with the +CEZ pad than without it (p < 0.05. The pin tract infection rate was reduced to one-fifth with the +CEZ pad. Using it as described improves infection resistance during percutaneous implantation.

  20. Some of the factors influencing the Heel Pad Compressibility Index (HPCI): a literature search

    DEFF Research Database (Denmark)

    Matteoli, Sara; Wilhjelm, Jens E.; Torp-Pedersen, Soren T.

    2009-01-01

    The human heel pad is a complex structure that features non-linear visco-elastic characteristics as the majority of the human soft tissues. The biomechanical aspects of the heel pad are still under investigation and the influence of subject factors such as age, weight, gender, height, race......, and body activity have been reported. The aim of this paper is to study the literature in order to identify the influence of subject factors and diseases on the heel pad compressibility index....

  1. Quadriceps fat pad edema: significance on magnetic resonance images of the knee

    International Nuclear Information System (INIS)

    Shabshin, Nogah; Schweitzer, Mark E.; Morrison, William B.

    2006-01-01

    While clinically reading magnetic resonance (MR) images of the knees we have occasionally noted edema within the suprapatellar fat pad, with mass effect both on the suprapatellar joint recess posteriorly, and on the quadriceps tendon anteriorly. This MR appearance is analogous to Hoffa's disease described in the infrapatellar fat pad. We sought to evaluate the frequency and pattern of this finding and to provide clinical and histological correlation. The suprapatellar (quadriceps) fat pad was evaluated in 770 consecutive MR examinations (on 1.5 T and 0.3 T) in 736 patients (353 females and 383 males, age range 5-86 years, mean 44.3 years). The MR images were retrospectively evaluated by two observers in consensus for the presence of quadriceps fat pad edema with mass effect. In 46 patients who had intravenous administration of gadolinium, the presence of enhancement was also evaluated. Clinical correlation was performed in abnormal cases; in one patient, 1-year follow-up MRI was evaluated and in one patient a percutaneous biopsy as well as 2-year clinical follow-up was performed. Thirty-two (4.2%) knees in 29 patients showed quadriceps fat pad edema and mass effect. In five of these patients imaging of the contralateral knee was also performed and four of these showed symmetric edema. Another five cases had gadolinium-enhanced images with prominent enhancement. Most patients had clinical symptoms of meniscal tears (n=16, 55%) or anterior knee pain (n=8, 27.6%). (orig.)

  2. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

    Science.gov (United States)

    Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav; Manoliu, Andrei

    2017-01-01

    To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p 3.0 T.

  3. Novel electrochemical approach to study corrosion mechanism of Al-Au wire-bond pad interconnections

    DEFF Research Database (Denmark)

    Elisseeva, O. V.; Bruhn, A.; Cerezo, J.

    2013-01-01

    A gold-aluminium material combination is typically employed as an interconnection for microelectronic devices. One of the reliability risks of such devices is that of corrosion of aluminium bond pads resulting from the galvanic coupling between an aluminium bond pad and a gold wire. The research...... presented in this manuscript focuses on studying bond pad corrosion by selecting an appropriate model system and a dedicated set of electrochemical and analytical experimental tools. Taking into account the complex three-dimensional structure and the small dimensions of Au-Al interconnections (around 50......-100 μm), a dedicated and novel experimental approach was developed. Au-Al covered silicon chips were developed under clean room conditions. Three-dimensional electrodes were mimicked as flat, two-dimensional bond pad model systems, allowing the use of microelectrochemical local probe techniques. Thin...

  4. Characterisation of Silicon Pad Diodes

    CERN Document Server

    Hodson, Thomas Connor

    2017-01-01

    Silicon pad sensors are used in high luminosity particle detectors because of their excellent timing resolution, radiation tolerance and possible high granularity. The effect of different design decisions on detector performance can be investigated nondestructively through electronic characterisation of the sensor diodes. Methods for making accurate measurements of leakage current and cell capacitance are described using both a standard approach with tungsten needles and an automated approach with a custom multiplexer and probing setup.

  5. Comparison of therapist implemented and iPad-assisted interventions for children with autism.

    Science.gov (United States)

    Lee, Allyson; Lang, Russell; Davenport, Katy; Moore, Melissa; Rispoli, Mandy; van der Meer, Larah; Carnett, Amarie; Raulston, Tracy; Tostanoski, Amy; Chung, Clare

    2015-04-01

    This study compares intervention delivered by a therapist to intervention delivered using an iPad for two children with autism. Further, this study evaluates the influence of choice between the conditions. Time on-task, challenging behaviour, session duration and correct responses were compared across conditions in an alternating treatment design. The effect of choice was evaluated in an ABAB design. The iPad was associated with shorter intervention sessions, more time on-task and less challenging behaviour for one participant. There was no difference between conditions for the second participant. Both participants selected the iPad when given the choice and, although the effect of choice was modest, choosing was associated with more time on-task and less challenging behaviour. These data suggest that iPad-assisted intervention can be as effective as therapist-implemented intervention. Further, even for children for whom no differences between the interventions exist, offering a choice may be beneficial.

  6. Head First iPhone and iPad Development A Learner's Guide to Creating Objective-C Applications for the iPhone and iPad

    CERN Document Server

    Pilone, Dan

    2011-01-01

    Let's say you have a killer app idea for iPhone and iPad. Where do you begin? Head First iPhone and iPad Development will help you get your first application up and running in no time. You'll not only learn how to design for Apple's devices, you'll also master the iPhone SDK tools -- including Interface Builder, Xcode, and Objective-C programming principles -- to make your app stand out. Whether you're a seasoned Mac developer who wants to jump into the App store, or someone with strong object-oriented programming skills but no Mac experience, this book is a complete learning experience for

  7. ImagePAD, a Novel Counting Application for the Apple iPad®, Used to Quantify Axons in the Mouse Optic Nerve

    Science.gov (United States)

    Templeton, Justin P.; Struebing, Felix L.; Lemmon, Andrew; Geisert, Eldon E.

    2014-01-01

    The present article introduces a new and easy to use counting application for the Apple iPad. The application “ImagePAD” takes advantage of the advanced user interface features offered by the Apple iOS® platform, simplifying the rather tedious task of quantifying features in anatomical studies. For example, the image under analysis can be easily panned and zoomed using iOS-supported multi-touch gestures without losing the spatial context of the counting task, which is extremely important for ensuring count accuracy. This application allows one to quantify up to 5 different types of objects in a single field and output the data in a tab-delimited format for subsequent analysis. We describe two examples of the use of the application: quantifying axons in the optic nerve of the C57BL/6J mouse and determining the percentage of cells labeled with NeuN or ChAT in the retinal ganglion cell layer. For the optic nerve, contiguous images at 60× magnification were taken and transferred onto an Apple iPad®. Axons were counted by tapping on the touch-sensitive screen using ImagePAD. Nine optic nerves were sampled and the number of axons in the nerves ranged from 38872 axons to 50196 axons with an average of 44846 axons per nerve (SD = 3980 axons). PMID:25281829

  8. Do foot pad scores measure Turkey welfare

    NARCIS (Netherlands)

    Hocking, P.M.; Harkness, A.; Veldkamp, Teun; Vinco, L.J.

    2017-01-01

    The main aim of the project was to assess the painfulness of different levels of foot pad dermatitis (FPD) in turkeys. Three different analgesics (butorphanol, carprofen and meloxicam) were used to assess their effect on behaviour. Video recordings were taken when the birds were treated with either

  9. Study on the prevention of spragging in a tilting pad journal bearing using the variation of preload

    International Nuclear Information System (INIS)

    Yang, Seong Heon; Park, Chul Hyun; Ha, Hyun Cheon; Kim, Chae Sil

    2001-01-01

    Tilting pad journal bearings have been widely used in a high speed rotating machinery, such as steam turbines and gas turbines, owing to their inherent stability characteristics. However, some peculiar fatigue failure in the babbitt metal due to spragging has been continuously occurred at the leading edge of the upper pads. The spragging is defined as the pad vibration initiated on the upper unloaded pads in tilting pad journal bearing. This paper describes both several kinds of bearing failure related with spragging and the theoretical investigation on the prevention of the spragging phenomenon using the variation of preload. Results show that positive preload(m>0.5) assures all pads remain statically loaded under all operating conditions. For the change of design parameter to prevent spragging, thermo-hydrodynamic lubrication and rotor dynamic analysis were performed to verify temperature limitation on bearing and vibration problems on rotor bearing system

  10. Wet adhesion with application to tree frog adhesive toe pads and tires

    International Nuclear Information System (INIS)

    Persson, B N J

    2007-01-01

    Strong adhesion between solids with rough surfaces is only possible if at least one of the solids is elastically very soft. Some lizards and spiders are able to adhere (dry adhesion) and move on very rough vertical surfaces due to very compliant surface layers on their attachment pads. Flies, bugs, grasshoppers and tree frogs have less compliant pad surface layers, and in these cases adhesion to rough surfaces is only possible because the animals inject a wetting liquid into the pad-substrate contact area, which generates a relative long-range attractive interaction due to the formation of capillary bridges. In this presentation I will discuss some aspects of wet adhesion for tree frogs and give some comments related to tire applications

  11. Wet adhesion with application to tree frog adhesive toe pads and tires

    Energy Technology Data Exchange (ETDEWEB)

    Persson, B N J [IFF, FZ-Juelich, 52425 Juelich (Germany)

    2007-09-19

    Strong adhesion between solids with rough surfaces is only possible if at least one of the solids is elastically very soft. Some lizards and spiders are able to adhere (dry adhesion) and move on very rough vertical surfaces due to very compliant surface layers on their attachment pads. Flies, bugs, grasshoppers and tree frogs have less compliant pad surface layers, and in these cases adhesion to rough surfaces is only possible because the animals inject a wetting liquid into the pad-substrate contact area, which generates a relative long-range attractive interaction due to the formation of capillary bridges. In this presentation I will discuss some aspects of wet adhesion for tree frogs and give some comments related to tire applications.

  12. Effectiveness of iPad apps on visual-motor skills among children with special needs between 4y0m-7y11m.

    Science.gov (United States)

    Coutinho, Franzina; Bosisio, Marie-Elaine; Brown, Emma; Rishikof, Stephanie; Skaf, Elise; Zhang, Xiaoting; Perlman, Cynthia; Kelly, Shannon; Freedin, Erin; Dahan-Oliel, Noemi

    2017-05-01

    The aim of this randomized controlled trial was to assess the effectiveness of interventions using iPad applications compared to traditional occupational therapy on visual-motor integration (VMI) in school-aged children with poor VMI skills. Twenty children aged 4y0m to 7y11m with poor VMI skills were randomly assigned to the experimental group (interventions using iPad apps targeting VMI skills) or control group (traditional occupational therapy intervention sessions targeting VMI skills). The intervention phase consisted of two 40-min sessions per week, over a period of 10 weeks. Participants were required to attend a minimum of 8 and a maximum of 12 sessions. The subjects were tested using the Beery-VMI and the visual-motor subscale of the M-FUN, at baseline and follow-up. Results from a 2-way mixed design ANOVA yielded significant results for the main effect of time for the M-FUN total raw score, as well as in the subscales Amazing Mazes, Hidden Forks, Go Fishing and VM Behavior. However, gains did not differ between intervention types over time. No significant results were found for the Beery-VMI. This study supports the need for further research into the use of iPads for the development of VMI skills in the pediatric population. Implications for Rehabilitation This is the first study to look at the use of iPads with school-aged children with poor visual-motor skills. There is limited literature related to the use of iPads in pediatric occupational therapy, while they are increasingly being used in practice. When compared to the traditional occupational therapy interventions, participants in the iPad intervention appeared to be more interested, engaged and motivated to participate in the therapy sessions. Using iPad apps as an adjunct to therapy in intervention could be effective in improving VMI skills over time.

  13. High dietary levels of biotin and zinc to improve health of foot pads in broilers exposed experimentally to litter with critical moisture content.

    Science.gov (United States)

    Abd El-Wahab, A; Radko, D; Kamphues, J

    2013-07-01

    Foot pad dermatitis (FPD) is a widespread problem in poultry production and constitutes a welfare issue. The objective of this study was to test potentially prophylactic effects of higher biotin and Zn levels in the diet of broilers exposed to critical litter moisture content (35% water) on the development of FPD. Two trials were performed in each 4 groups of 1-wk-old male broilers (Ross 708) during 33 d. The pens of all groups (25 birds in each) were littered with wood shavings of critical moisture content. Two groups were fed high levels of Zn as zinc-oxide (150 mg/kg of diet), with normal levels of biotin (300 µg/kg of diet) or high biotin (2,000 µg/kg of diet). The other 2 groups were fed Zn as zinc-methionine (150 mg/kg of diet), with normal levels of biotin (300 µg/kg of diet) or high biotin (2,000 µg/kg of diet). External assessment of foot pads and measurements the moisture contents of excreta and litter were performed weekly. The signs of foot pad lesions were recorded on a 7-point scale (0 = normal skin; 7 = more than half of the foot pad is necrotic). High biotin supplementation resulted in a reduction of 30 and 18% of cases of foot pad lesions in trials 1 and 2, respectively. The combination of Zn-methionine and high biotin supplementation led to a decreased severity of FPD in a range of about 50 and 30% in trials 1 and 2, respectively. In broilers fed the diet containing zinc-oxide and normal biotin levels about 28 and 24% of the birds had the scores of 6 and 7 (= high foot pad alterations), whereas in birds fed Zn-methionine and high biotin no high alterations (score = 7) in the foot pad (0%) occurred in either trial. The presented results suggest that it is advisable to combine the maximum levels of Zn (especially of Zn-methionine) and high levels of biotin when clinically relevant alterations in the foot pad occur.

  14. Addressable Inverter Matrix Tests Integrated-Circuit Wafer

    Science.gov (United States)

    Buehler, Martin G.

    1988-01-01

    Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.

  15. Using iPad-Based Mobile Learning to Teach Creative Engineering within a Problem-Based Learning Pedagogy

    Science.gov (United States)

    Li, Yulong; Wang, Lixun

    2018-01-01

    This case study, noting the increasing interest in iPad-based mobile learning research and aware of the current dearth of engineering talent in the UK, aims to contribute to a still sparse area of research that links iPad use to engineering education. To achieve this, the study investigates the integration of iPad-based mobile learning…

  16. iPad® Use in Children and Young Adults with Autism Spectrum Disorder: An Observational Study

    Science.gov (United States)

    King, Amie M.; Thomeczek, Melissa; Voreis, Grayce; Scott, Victoria

    2014-01-01

    This exploratory study was conducted to describe how children and young adults with autism spectrum disorder (ASD) are currently using iPads® and applications, to explore the role of education professionals on iPad® and application use, and to determine potential research needs regarding iPad® use in children with ASD. Naturalistic observations…

  17. The role of the iPad in collaborative learning in a large-enrollment first-year physics module

    Science.gov (United States)

    van der Ventel, Brandon; Newman, Richard; Botes, Lise; Goldberg, Alan

    2016-07-01

    The role of the iPad was investigated in the possible enhancement of collaborative learning within a tutorial setting in a large-enrollment first-year physics module. Every tutorial session was divided into an ‘iPad group’ and a ‘non-iPad group’. A set of core apps was chosen to facilitate discussion within the group. In order to maintain parity across the two groups, all the tutorial questions had to be refitted into a form suitable for use with the iPad. The results of a survey done after each tutorial indicates that, qualitatively, the iPad significantly enhanced the learning experience and strongly contributed to discussion within the group.

  18. iPads and LCDs show similar performance in the detection of pulmonary nodules

    Science.gov (United States)

    McEntee, Mark F.; Lowe, Joanna; Butler, Marie Louise; Pietrzyk, Mariusz; Evanoff, Michael G.; Ryan, John; Brennan, Patrick C.; Rainford, Louise A.

    2012-02-01

    In February 2011 the University of Chicago Medical School distributed iPads to its trainee doctors for use when reviewing clinical information and images on the ward or clinics. The use of tablet computing devices is becoming widespread in medicine with Apple™ heralding them as "revolutionary" in medicine. The question arises, just because it is technical achievable to use iPads for clinical evaluation of images, should we do so? The current work assesses the diagnostic efficacy of iPads when compared with LCD secondary display monitors for identifying lung nodules on chest x-rays. Eight examining radiologists of the American Board of Radiology were involved in the assessment, reading chest images on both the iPad and the an off-the-shelf LCD monitor. Thirty chest images were shown to each observer, of which 15 had one or more lung nodules. Radiologists were asked to locate the nodules and score how confident they were with their decision on a scale of 1-5. An ROC and JAFROC analysis was performed and modalities were compared using DBM MRMC. The results demonstrate no significant differences in performance between the iPad and the LCD for the ROC AUC (p<0.075) or JAFROC FOM (p<0.059) for random readers and random cases. Sample size estimation showed that this result is significant at a power of 0.8 and an effect size of 0.05 for ROC and 0.07 for JAFROC. This work demonstrates that for the task of identifying pulmonary nodules, the use of the iPad does not significantly change performance compared to an off-the-shelf LCD.

  19. Evaluation of comfort in bedridden older adults using an air-cell mattress with an automated turning function: measurement of parasympathetic activity during night sleep.

    Science.gov (United States)

    Futamura, Megumi; Sugama, Junko; Okuwa, Mayumi; Sanada, Hiromi; Tabata, Keiko

    2008-12-01

    This study objectively evaluated the degree of comfort in bedridden older adults using an air-cell mattress with an automated turning mechanism. The sample included 10 bedridden women with verbal communication difficulties. The high frequency (HF) components of heart rate variability, which reflect parasympathetic nervous activity, were compared for the manual and automated turning periods. No significant differences in the HF component were observed in 5 of the participants. Significant increases in the HF component associated with automated turning were observed in 3 participants; however, the two participants with the lowest body mass index values exhibited a significant reduction in the HF component during the automated turning period. The results revealed that comfort might not be disturbed during the automated turning period.

  20. Smoking is associated with increased levels of extracellular peptidylarginine deiminase 2 (PAD2) in the lungs

    DEFF Research Database (Denmark)

    Damgaard, Dres; Friberg Bruun Nielsen, Michael; Quisgaard Gaunsbaek, Maria

    2015-01-01

    lavage (BAL) fluid from smokers, but intracellularly located PAD cannot be responsible for citrullination of extracellular self-antigens. We aimed to establish a link between smoking and extracellular PAD2 in the lungs. METHODS: BAL fluid samples were obtained from 13 smokers and 11 nonsmoking controls...... fluids from smokers as compared to non-smokers (p=0.018). The PAD2 content correlated with the overall CRP levels (p=0.009) and cell count (p=0.016). CONCLUSIONS: This first demonstration of increased levels of extracellular PAD2 in the lungs of smokers supports the hypothesis that smoking promotes...

  1. 49 CFR 393.47 - Brake actuators, slack adjusters, linings/pads and drums/rotors.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Brake actuators, slack adjusters, linings/pads and..., slack adjusters, linings/pads and drums/rotors. (a) General requirements. Brake components must be... same size. (c) Slack adjusters. The effective length of the slack adjuster on each end of an axle must...

  2. 16 CFR 1633.7 - Mattress test procedure.

    Science.gov (United States)

    2010-01-01

    ... consumption calorimetry. The calibration should follow generally accepted practices for calibration. The... Grade 10 machining practice with a well formed #53 drill bit). The holes shall point 5° out of the plane... practice with a well formed #53 drill bit). The holes shall point 5° out of the plane of the diagram in...

  3. Thermal–Hydrodynamic Behaviour of Coated Pivoted Pad Thrust Bearings: Comparison between Babbitt, PTFE and DLC

    Directory of Open Access Journals (Sweden)

    Konstantinos Katsaros

    2018-05-01

    Full Text Available The hydrodynamic lubrication and thermal analysis of tilting pad thrust bearings has been a major subject for many studies in the field of tribology. There is only a limited number of studies regarding thrust bearings with coated surfaces. The purpose of this study is to build a parametric, iterative algorithm in order to perform a complete thermal and hydrodynamic lubrication analysis for pivoted pad thrust bearings with coatings. The analytical model is mainly based on the energy, continuity and Navier–Stokes equations, which are solved numerically with the Semi-Implicit Method for Pressure Linked Equations Consistent (SIMPLEC method. The analysis focuses on a single pivoted pad of the thrust bearing. The thermal properties of the coating material are taken into account and the resulting thermal and flow fields are solved. The basic hydrodynamic and tribological characteristics are calculated for an uncoated, a Babbitt coated, a PTFE coated and a diamond like carbon (DLC coated pivoted pad thrust bearing. The pressure and the film thickness distribution, as well as the load capacity and the frictional forces, are determined for several pad positions and velocities of the rotor. A mineral oil lubricant is used to estimate the shear thinning or thickening effects on the pad tribological performance. The results indicate that pads coated with PTFE and DLC show lower friction forces compared to the common steel and Babbitt applications. At the same time, the DLC coating seems to affect the bearing’s flow and thermal fields less than the PTFE, making it more suitable for thrust bearings applications.

  4. Diamond pad detector telescope for beam conditions and luminosity monitoring in ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Mikuz, M. [Jozef Stefan Institute and Department of Physics, University of Ljubljana, Ljubljana (Slovenia)], E-mail: Marko.Mikuz@ijs.si; Cindro, V.; Dolenc, I. [Jozef Stefan Institute and Department of Physics, University of Ljubljana, Ljubljana (Slovenia); Frais-Koelbl, H. [University of Applied Sciences Wiener Neustadt and Fotec, Wiener Neustadt (Austria); Gorisek, A. [CERN, Geneva (Switzerland); Griesmayer, E. [University of Applied Sciences Wiener Neustadt and Fotec, Wiener Neustadt (Austria); Kagan, H. [Ohio State University, Columbus (United States); Kramberger, G.; Mandic, I. [Jozef Stefan Institute and Department of Physics, University of Ljubljana, Ljubljana (Slovenia); Niegl, M. [University of Applied Sciences Wiener Neustadt and Fotec, Wiener Neustadt (Austria); Pernegger, H. [CERN, Geneva (Switzerland); Trischuk, W. [University of Toronto, Toronto (Canada); Weilhammer, P. [CERN, Geneva (Switzerland); Zavrtanik, M. [Jozef Stefan Institute and Department of Physics, University of Ljubljana, Ljubljana (Slovenia)

    2007-09-01

    Beam conditions and the potential detector damage resulting from their anomalies have pushed the LHC experiments to plan their own monitoring devices in addition to those provided by the machine. ATLAS decided to build a telescope composed of two stations with four diamond pad detector modules each, placed symmetrically around the interaction point at z={+-}183.8cm and r{approx}55mm ({eta}{approx}4.2). Equipped with fast electronics it allows time-of-flight separation of events resulting from beam anomalies from normally occurring p-p interactions. In addition it will provide a coarse measurement of the LHC luminosity in ATLAS. Ten detector modules have been assembled and subjected to tests, from characterization of bare diamonds to source and beam tests. Preliminary results of beam test in the CERN PS indicate a signal-to-noise ratio of 14{+-}2.

  5. Diamond pad detector telescope for beam conditions and luminosity monitoring in ATLAS

    International Nuclear Information System (INIS)

    Mikuz, M.; Cindro, V.; Dolenc, I.; Frais-Koelbl, H.; Gorisek, A.; Griesmayer, E.; Kagan, H.; Kramberger, G.; Mandic, I.; Niegl, M.; Pernegger, H.; Trischuk, W.; Weilhammer, P.; Zavrtanik, M.

    2007-01-01

    Beam conditions and the potential detector damage resulting from their anomalies have pushed the LHC experiments to plan their own monitoring devices in addition to those provided by the machine. ATLAS decided to build a telescope composed of two stations with four diamond pad detector modules each, placed symmetrically around the interaction point at z=±183.8cm and r∼55mm (η∼4.2). Equipped with fast electronics it allows time-of-flight separation of events resulting from beam anomalies from normally occurring p-p interactions. In addition it will provide a coarse measurement of the LHC luminosity in ATLAS. Ten detector modules have been assembled and subjected to tests, from characterization of bare diamonds to source and beam tests. Preliminary results of beam test in the CERN PS indicate a signal-to-noise ratio of 14±2

  6. 190-C Facility <90 Day Storage Pad training plan

    International Nuclear Information System (INIS)

    Little, N.C.

    1996-12-01

    This is the Environmental Restoration Contractor (ERC) team training plan for the 190-C Facility <90 Day Storage Pad of Hazardous Waste. It is intended to meet the requirements of Washington Administrative Code (WAC) 173-303-330 and the Hanford Dangerous Waste Permit. Training unrelated to compliance with WAC 173-303-330 is not addressed in this training plan. WAC 173-303-330(1)(d)(ii, v, vi) requires that personnel be familiarized, where applicable, with waste feed cut-off systems, response to ground-water contamination incidents, and shutdown of operations. These are not applicable to 190-C Facility <90 Day Storage Pad, and are therefore not covered in this training plan

  7. Design charts for arbitrarily pivoted, liquid-lubricated flat-sector-pad thrust bearing

    Science.gov (United States)

    Etsion, I.

    1977-01-01

    A flat, sector-shaped geometry for a liquid-lubricated thrust bearing is analyzed considering both the pitch and roll of the pad. Results are presented in design charts that enable a direct approach to the design of point- and line-pivoted, tilting pad bearings. A comparison is made with the Mitchell bearing approximation and it is found that this approximation always overestimates load capacity.

  8. Accumulation of Arsenic and Mercury in Different Bio-bed Padding Materials

    Directory of Open Access Journals (Sweden)

    LIU Tian-yu

    2016-07-01

    Full Text Available In order to study the accumulation and distribution of As, Hg in different bio-bed padding materials while implementing bio-bed raising method, three kinds of bio-bed padding materials were well designed, which consisted of sawdust(S, sawdust + rice husk(SR and sawdust + rice husk + straw(SRS. For a year and a half, the contents of As, Hg at different depth were measured when four groups of fattening pig breeding had finished to analyze the accumulation and distribution of As, Hg in different bio-bed padding materials, which could provide a theoretical basis for follow-up application of bio-bed padding materials in agriculture. The results showed that, the accumulation of As and Hg, at different levels, occurred during four pig-raising cycles. When 4 groups of fattening pig breeding finished, the largest accumulation of As and Hg occurred in SRS bio-beds, respectively reached 1921.7 mg per sty and 21.1 mg per sty. The As and Hg contents of S, SR,SRS were 2.921, 2.190, 2.621 mg·kg-1 and 0.048, 0.036, 0.042 mg·kg-1, respectively, which met the China's Organic Fertilizer Agriculture Standards(NY 525-2012, and Farmland Environmental Quality Evaluation Standards For Edible Agricultural Products(HJ/T 332-2006.

  9. KONTRIBUSI TAMAN WISATA ALAM BANTIMURUNG TERHADAP PENDAPATAN ASLI DAERAH (PAD KABUPATEN MAROS

    Directory of Open Access Journals (Sweden)

    Nur Fitri Syam

    2017-06-01

    Full Text Available Fitri Nur Syam, 2016. "The Contribution of the Nature Park Bantimurung Against Local Revenue (PAD Maros". Thesis Supervised by Dr. H. A. Arifuddin Mane, SE, M.Si, SH, MH as a supervisor I and Drs.Syamsuddin Djafar SE., M.Si as Supervisor II. This study aims to determine the magnitude Contributions Levy Park Nature Bantimurung to local revenue (PAD Maros. The research was conducted at the Department of Tourism and Maros. Data used in the thesis, is derived from PAD report Maros 2011-2013 period and some literature review. Data analysis method used is descriptive analysis method is to describe how much the contribution levy Bantimurung Against Nature Park Local Revenue Maros. Based on the results of the analysis that the value of PAD acceptance Maros continuously increased from 2011 to 2015. On the other hand, the value of levy receipts TWAB fluctuate, ie from 2011 to 2012 has increased the amount of Rp 2,596,094,700, an increase amounting to 57.65%, whereas from 2012 to 2013 the value of the levy TWAB decreased by Rp 1,977,385,700, or decreased (-27.8%. Selanjutanya, from 2013 to 2014 the value of retribution TWAB rise again, but the increase is small with only Rp 1,538,205,400, an increase of 30.03%. But from 2014 to 2015 the value of retribution decreased again by Rp 227 134 100 or decreased (-3.4%. In general, the value of the contribution to the PAD TWAB Maros from 2011-2015 epidemic is still relatively small, even declining since 2013. From the calculation of value contribution TWAB retribution against PAD Maros years 2011-2015 shows that the greatest value of the contribution that only happens in 2012 which reached 8.26%, while the value of the contribution of three years thereafter relatively small, especially in 2015 which only amounted to 4.61%.

  10. Production of cathode pad chambers for 2nd muon tracking station of ALICE

    International Nuclear Information System (INIS)

    Danish Azmi, M.; Irfan, M.; Khan, I.A.; Bose, S.; Chattopadhyay, S.; Das, D.; Das, I.; Datta, P.; Dutt-Mazumder, A.K.; Jana, S.; Pal, S.; Paul, L.; Roy, P.; Sinha, T.; Sinha, B.C.

    2005-01-01

    The second tracking station of dimuon spectrometer of ALICE comprises of 8 cathode pad chambers whose inner radius is 23.7 cm and outer radius is 117 cm. The anode to cathode separation is 2.5 cm and the operating voltage of these chambers is around 1675 volt at an atmospheric pressure of 80% Ar + 20% CO 2 . At this operating point, the gain of the chamber is around 10 5 . In this report the quality control tests on the first production chamber have been reported

  11. Insertion of a tokamak divertor drawer on air-pads demonstrated

    International Nuclear Information System (INIS)

    Removille, J.

    1984-01-01

    In the course of the INTOR-NET project remote maintenance studies, the need arose for withdrawing from the torus two divertor segments, one of which needed a composite movement (no straight movement). The solution designed at that time, an autonomous floating platform crawling under the segment and lifting it, needed to be demonstrated. The scope, the characteristics of the prototype built, and the difficulties during manufacturing related mainly to the reading of the floor track (type of track, type of detector), to the load equilibrium (pad pressure distribution and control), and to the floor slit crossing (pad row retraction) are described

  12. Professional and Parental Attitudes toward iPad Application Use in Autism Spectrum Disorder

    Science.gov (United States)

    Clark, Megan L. E.; Austin, David W.; Craike, Melinda J.

    2015-01-01

    This study explored the attitudes of parents and professionals who work with children with autism spectrum disorder (ASD) toward the utilization of iPads and use of iPad applications by children with ASD. A survey of parents (n = 90) and professionals (n = 31) assessed information and communication technology (ICT) anxiety and self-efficacy,…

  13. iPad Use for Accelerating Reading Gains in Secondary Students with Learning Disabilities

    Science.gov (United States)

    Retter, Shannan; Anderson, Christine; Kieran, Laura

    2013-01-01

    This action research project explored the use of the iPad 2 in a special education classroom with high school students who were considered struggling readers to determine if an academic gain in reading comprehension, reading fluency, and vocabulary implementing the intervention of an iPad and four specific applications (apps). The high school…

  14. Factors affecting stall use for different freestall bases.

    Science.gov (United States)

    Wagner-Storch, A M; Palmer, R W; Kammel, D W

    2003-06-01

    The objective of this study was to compare stall use (stall occupancy and cow position) by barn side for factors affecting stall use. A closed circuit television system recorded stall use four times per day for a 9-mo period starting May 9, 2001. Six factors were analyzed: stall base, distance to water, stall location within stall base section, stall location within barn, inside barn temperature, and length of time cows were exposed to stall bases. Two barn sides with different stocking densities were analyzed: low (66%), with cows milked by robotic milker; and high (100%), with cows milked 2X in parlor. Six stall base types were tested: two mattresses, a waterbed, a rubber mat, concrete, and sand (high side only). The base types were grouped 3 to 7 stalls/section and randomly placed in each row. Cows spent more time in mattress-based stalls, but the highest percentage lying was in sand-based stalls. The following significant stall occupancy percentages were found: sand had the highest percentage of cows lying on the high stocking density side (69%), followed by mattress type 1 (65%) > mattress type 2 (57%) > waterbed (45%) > rubber mat (33%) > concrete (23%). Mattress type 1 had the highest percentage stalls occupied (88%), followed by mattress type 2 (84%) > sand (79%) > soft rubber mat (65%) > waterbed (62%) > concrete (39%). On the low stocking rate side, mattress type 1 had the highest percentage cows lying (45%) and occupied (59.6%), followed by mattress type 2 > waterbed > soft rubber mat > concrete. Cow lying and stalls occupied percentages were highest for stalls 1) not at the end of a section, and 2) on the outside row, and varied by base type for time cows exposed to stalls and inside barn temperature. Lying and occupied percentages were different for different mattress types. The percentage of stalls with cows standing was higher for mat and mattress-based stalls. Results show mattress type 1 and sand to be superior and rubber mats and concrete inferior

  15. Cognitively Accessible Academic Lessons for Students with Intellectual Disabilities Using the iPad

    Science.gov (United States)

    Gunderson, Jamie Linn; Higgins, Kyle; Morgan, Joseph John; Tandy, Richard; Brown, Monica R.

    2017-01-01

    The purpose of this study was to improve access to general education curricula, through the use of an iPad, for students with intellectual disabilities (IDs). The participants were 72 students (kindergarten through eighth grade) identified as having an ID. During the 6-week study, the 41 students in the experimental iPad group received academic…

  16. The iPad as an Instructional Tool: An Examination of Teacher Implementation Experiences

    Science.gov (United States)

    Benton, Brandie Kay

    2012-01-01

    At present, handheld devices and tablet computers are infiltrating public schools across the nation, the most popular model being the Apple iPad. Schools and teachers are attempting to integrate the devices and are using a variety of methods and models for implementation. The purpose of this study was to examine the implementation of the iPad as…

  17. Evaluation of the iPad as a low vision aid for improving reading ability.

    Science.gov (United States)

    Haji, Shamim A; Sambhav, Kumar; Grover, Sandeep; Chalam, Kakarla V

    2015-01-01

    To evaluate the effect of the iPad as a low vision aid in improving the reading ability of low vision patients (LVPs). In this study, 228 consecutive patients that came for their routine eye care examination at the University of Florida, Jacksonville eye clinic, were enrolled. Patients met inclusion criteria if they had best-corrected visual acuity (BCVA) of 20/100 or worse in the best corrected eye and were willing to participate in the study. The patient's reading ability was assessed both with the patient's own spectacles and an iPad. Patients were encouraged to enlarge the reading material as well as change the contrast until they could read comfortably. The number of patients able to read the text comfortably was recorded. Out of the total 228 participants who qualified, 103 (45%) were male and 125 (55%) were female. Only 22% could read standard newsprint-sized text (N8) without the help of an iPad. With the help of an iPad, 94% participants with impaired vision were able to read standard newsprint-sized text (N8) or smaller text (PiPad, a new portable electronic media device, can be adapted by LVPs to improve their reading ability.

  18. THE INFLUENCE OF BRAKE PADS THERMAL CONDUCTIVITY ON PASSANGER CAR BRAKE SYSTEM EFFICIENCY

    Directory of Open Access Journals (Sweden)

    Predrag D Milenković

    2010-01-01

    Full Text Available In phase of vehicle braking system designing, besides of mechanical characteristics, it is also necessary to take under consideration the system's thermal features. This is because it is not enough just to achieve proper braking power, for the brake system to be effective but equally important thing is the dissipation of heat to the environment. Heat developed in the friction surfaces dissipate into the environment over the disk in one hand and through the brake linings and caliper, in the other. The striving is to make that greatest amount of heat to dissipate not threw the brake pads but threw disc. The experimental researching of heat transfer process taking place at vehicle brakes was made in the R&D Center of "Zastava automobili" car factory in order to increase the efficiency of brake system. The standard laboratory and road test procedures were used, according to factory quality regulations. The modern equipment such as thermo camera, thermo couples, torque transducers, signal amplifiers, optical speed measuring system and laptop computer were used. In this paper will be shown the part of the experimental researching, which refers to the thermal conductivity of brake pad friction linings.

  19. Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    Science.gov (United States)

    Takeuchi, Akihiro; Ishida, Kai; Morohoshi, Yasuo; Shinbo, Toshihiro; Hirose, Minoru; Ikeda, Noriaki

    2010-02-01

    Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a basic photo sensor. The photo sensor consisted of an ordinary electrical circuit, a light emitting diode (LED, lambda max = 645 nm), a photo diode (PD), and a thin gauze pad placed between the LED and PD that were tightly attached to the edges of a plastic clip. The light transmitted through the gauze pad, soaked with liquids or porcine blood dropped on it, was measured with a digital voltmeter. The liquids were reverse osmosis water, physiological saline, glucose in water at 5, 10, 20, 40 and 50%, porcine plasma, and porcine blood (Hct 40, 30 and 20%). The liquids on a tight-weave gauze pad, significantly increased the voltage (light transmission) from 0.412 +/- 0.003 V (SD) to 0.794 +/- 0.025 V (minimum, by reverse osmosis water) and to 0.945 +/- 0.011 V (maximum, by 50% glucose). The porcine blood significantly decreased the voltage from 0.412 to 0.195 +/- 0.030 V in Hct 40%, to 0.334 +/- 0.035 in Hct 30%, to 0.397 +/- 0.007 V in Hct 20%. The higher the concentration of glucose, the more the light transmission increased. The higher concentration of Hct, the more the light transmission decreased. Similar results were also shown for the loose-weave pad. Using two types of gauze pads, we confirmed that liquids significantly increased light transmission through gauze pad, but porcine blood decreased light transmission. This opposite response can be used to distinguish liquids from blood on a gauze pad.

  20. Remora fish suction pad attachment is enhanced by spinule friction.

    Science.gov (United States)

    Beckert, Michael; Flammang, Brooke E; Nadler, Jason H

    2015-11-01

    The remora fishes are capable of adhering to a wide variety of natural and artificial marine substrates using a dorsal suction pad. The pad is made of serial parallel pectinated lamellae, which are homologous to the dorsal fin elements of other fishes. Small tooth-like projections of mineralized tissue from the dorsal pad lamella, known as spinules, are thought to increase the remora's resistance to slippage and thereby enhance friction to maintain attachment to a moving host. In this work, the geometry of the spinules and host topology as determined by micro-computed tomography and confocal microscope data, respectively, are combined in a friction model to estimate the spinule contribution to shear resistance. Model results are validated with natural and artificially created spinules and compared with previous remora pull-off experiments. It was found that spinule geometry plays an essential role in friction enhancement, especially at short spatial wavelengths in the host surface, and that spinule tip geometry is not correlated with lamellar position. Furthermore, comparisons with pull-off experiments suggest that spinules are primarily responsible for friction enhancement on rough host topologies such as shark skin. © 2015. Published by The Company of Biologists Ltd.

  1. Fat-suppressed MR images of both hands obtained using CHESS can be improved by rice pads.

    Science.gov (United States)

    Moriya, Susumu; Miki, Yukio; Kamishima, Tamotsu; Kanagaki, Mitsunori; Yokobayashi, Tsuneo; Ishikawa, Mitsunori

    2012-09-01

    When chemical shift selective (CHESS) imaging is used with magnetic resonance imaging (MRI) for simultaneous imaging of both hands for the evaluation of rheumatoid arthritis, the fat suppression effect is poor. We investigated whether these fat-suppressed images using CHESS could be improved with the use of rice pads. T1-weighted images were obtained with CHESS and the same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. Patients were placed in a prone position with both hands extended overhead. The fat-suppression effect was classified into four categories and scored for both sets of images, and visual assessments were made by one radiologist and one radiologic technologist. The evaluation score was 1.1 for the images made without rice pads, and 3.2 for the images made with rice pads. The fat suppression effect was thus significantly better in the images made using rice pads (PCHESS with rice pads, and it was confirmed that the images were improved and had good fat suppression. More accurate evaluation of inflammatory sites that occur in rheumatoid arthritis may thus be possible, promising better diagnostic accuracy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Fat-suppressed MR images of both hands obtained using CHESS can be improved by rice pads

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, Susumu, E-mail: smoyari@yahoo.co.jp [Ishikawa Clinic, 46-1 Shimokamo-Umenoki-cho, Sakyo-ku, Kyoto-shi, Kyoto 606-0851 (Japan); Miki, Yukio [Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585 (Japan); Kamishima, Tamotsu [Department of Biomedical Sciences and Engineering, Hokkaido University Graduate School of Health Science, North-12 West-5 Kita-ku, Sapporo 060-0812 (Japan); Kanagaki, Mitsunori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, 54 Shogoin-kawahara-cho, Sakyo-ku, Kyoto-shi, Kyoto 606-8507 (Japan); Yokobayashi, Tsuneo; Ishikawa, Mitsunori [Ishikawa Clinic, 46-1 Shimokamo-Umenoki-cho, Sakyo-ku, Kyoto-shi, Kyoto 606-0851 (Japan)

    2012-09-15

    When chemical shift selective (CHESS) imaging is used with magnetic resonance imaging (MRI) for simultaneous imaging of both hands for the evaluation of rheumatoid arthritis, the fat suppression effect is poor. We investigated whether these fat-suppressed images using CHESS could be improved with the use of rice pads. T1-weighted images were obtained with CHESS and the same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. Patients were placed in a prone position with both hands extended overhead. The fat-suppression effect was classified into four categories and scored for both sets of images, and visual assessments were made by one radiologist and one radiologic technologist. The evaluation score was 1.1 for the images made without rice pads, and 3.2 for the images made with rice pads. The fat suppression effect was thus significantly better in the images made using rice pads (P < 0.0001). Lingering fat signals disappeared almost completely in images of both hands using CHESS with rice pads, and it was confirmed that the images were improved and had good fat suppression. More accurate evaluation of inflammatory sites that occur in rheumatoid arthritis may thus be possible, promising better diagnostic accuracy.

  3. Fat-suppressed MR images of both hands obtained using CHESS can be improved by rice pads

    International Nuclear Information System (INIS)

    Moriya, Susumu; Miki, Yukio; Kamishima, Tamotsu; Kanagaki, Mitsunori; Yokobayashi, Tsuneo; Ishikawa, Mitsunori

    2012-01-01

    When chemical shift selective (CHESS) imaging is used with magnetic resonance imaging (MRI) for simultaneous imaging of both hands for the evaluation of rheumatoid arthritis, the fat suppression effect is poor. We investigated whether these fat-suppressed images using CHESS could be improved with the use of rice pads. T1-weighted images were obtained with CHESS and the same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. Patients were placed in a prone position with both hands extended overhead. The fat-suppression effect was classified into four categories and scored for both sets of images, and visual assessments were made by one radiologist and one radiologic technologist. The evaluation score was 1.1 for the images made without rice pads, and 3.2 for the images made with rice pads. The fat suppression effect was thus significantly better in the images made using rice pads (P < 0.0001). Lingering fat signals disappeared almost completely in images of both hands using CHESS with rice pads, and it was confirmed that the images were improved and had good fat suppression. More accurate evaluation of inflammatory sites that occur in rheumatoid arthritis may thus be possible, promising better diagnostic accuracy

  4. Infrapatellar fat pad haemangioma: Case report

    Directory of Open Access Journals (Sweden)

    Dzoleva-Tolevska Roza

    2014-07-01

    Full Text Available We present a case of a 38-year-old woman with a soft tissue mass on the right knee in medial infrapatellar area. The flexion of the knee appeared to be limited and a pain was present at maximal flexion. Ultrasonography, standard X-ray and CT scan were performed for diagnosis of this soft tissue tumour. MRI was not done due to technical problems. Anyhow the MRI could provide us with more presumptions of the type of the tumour, but it will not affect the surgeon's decision for operation. Anyway the final diagnosis will come out of the histopatological findings. Arthroscopic examination was performed in order to eliminate possible problems into the joint followed by open wide excision. A soft tissue tumour with dimensions of 5 x 4 x 1.5 cm was excised. Histopathological diagnosis was synovial haemangioma located in the infrapatellar fat pad. The patient was asymptomatic postoperatively. Haemangiomas located in infrapatellar fat pad are rare. Orthopaedic surgeons can often be confused by more common entities like chondromallatia of patella, synovitis of the knee, Hoffa's disease, other soft tissue tumours, even lesion of meniscus. So, accurate diagnosis is very important for differentiation. Operative excision, arthroscopic or open wide, is definitive treatment for this benign tumour.

  5. Pad printing as a film forming technique for polymer solar cells

    DEFF Research Database (Denmark)

    Krebs, Frederik C

    2009-01-01

    coated transparent zinc oxide front electrode, a pad printed active layer based on a bulk heterojunction of the thermocleavable polymer poly(3-(2-methylhexyloxycarbonyl)thiophene-co-thiopene) (P3MHOCT) and zinc oxide nanoparticles, spin coated PEDOT:PSS and finally a manually cast thermally cured silver...... cells prepared by pad printing are presented. Devices were prepared on indium tin oxide substrates but in principle the entire photovoltaic device comprising front and back electrodes, barrier layers and active layer could be printed with no need for vacuum steps. The device geometry comprises a spin...

  6. Evaluation of the iPad as a low vision aid for improving reading ability

    Directory of Open Access Journals (Sweden)

    Haji SA

    2014-12-01

    Full Text Available Shamim A Haji, Kumar Sambhav, Sandeep Grover, Kakarla V Chalam Department of Ophthalmology, University of Florida College of Medicine, Jacksonville, FL, USA Purpose: To evaluate the effect of the iPad as a low vision aid in improving the reading ability of low vision patients (LVPs. Methods: In this study, 228 consecutive patients that came for their routine eye care examination at the University of Florida, Jacksonville eye clinic, were enrolled. Patients met inclusion criteria if they had best-corrected visual acuity (BCVA of 20/100 or worse in the best corrected eye and were willing to participate in the study. The patient’s reading ability was assessed both with the patient’s own spectacles and an iPad. Patients were encouraged to enlarge the reading material as well as change the contrast until they could read comfortably. The number of patients able to read the text comfortably was recorded. Results: Out of the total 228 participants who qualified, 103 (45% were male and 125 (55% were female. Only 22% could read standard newsprint-sized text (N8 without the help of an iPad. With the help of an iPad, 94% participants with impaired vision were able to read standard newsprint-sized text (N8 or smaller text (P<0.01. Conclusion: The iPad, a new portable electronic media device, can be adapted by LVPs to improve their reading ability. Keywords: low vision devices, low vision patient, LVP, iPad

  7. iPads: Intuitive Technology for 21st-Century Students

    Science.gov (United States)

    Siegle, Del

    2013-01-01

    The purpose of this article is to provide a rationale for using iPad technology with young students. Various inexpensive apps are described that parents and educators will find useful. (Contains 9 figures.)

  8. Reading from an iPad or from a book in bed: the impact on human sleep. A randomized controlled crossover trial.

    Science.gov (United States)

    Grønli, Janne; Byrkjedal, Ida Kristiansen; Bjorvatn, Bjørn; Nødtvedt, Øystein; Hamre, Børge; Pallesen, Ståle

    2016-05-01

    To objectively and subjectively compare whether reading a story for 30 min from an iPad or from a book in bed prior to sleep will differentially affect sleep. Sixteen students (12 females, mean age 25.1 ± 2.9 years) underwent ambulatory (sleeping in their own beds at home) polysomnographic (PSG) recordings in a counterbalanced crossover design consisting of three PSG nights (one adaptation night, two test nights) and two different reading materials: read from an iPad or from a book. Illumination was measured during reading and Karolinska Sleepiness Scale was completed prior to turning the light off. Sleep diaries were kept to assess subjective sleep parameters from day to day. Illumination was higher in the iPad condition compared to the book condition (58.3 ± 6.9 vs 26.7 ± 8.0 lux, p book. No parameters of sleep state timing and sleep onset latency differed between the two reading conditions. Although there was no direct effect on time spent in different sleep states and self-reported sleep onset latency, the use of an iPad which emits blue enriched light impinges acutely on sleepiness and EEG characteristics of sleep pressure. Hence, the use of commercially available tablets may have consequences in terms of alertness, circadian physiology, and sleep. Published by Elsevier B.V.

  9. Lumbar facet joint fat pads: Their normal anatomy and their appearance when enlarged

    International Nuclear Information System (INIS)

    Taylor, J.R.; McCormick, C.C.

    1991-01-01

    The polar recesses, superior and inferior to lumbar facet joints, are filled by fat pads from which fat-filled synovial folds project between the articular surfaces for a distance of two to four millimetres. The intracapsular superior recess lies between the ligamentum flavum and the lamina above. The extracapsular inferior recess lies on the back of the lamina below and communicates with the joint through a hole in the inferior capsule. The intracapsular folds move freely in and out of the joint during movements. These features are demonstrated in anatomic studies using transverse sections and radiologic studies using computed tomography. In about 4% of lumbar spines examined, the intraarticular fat pads are enlarged and extend from the joint recess(es) into the middle third of one or more facet joints. The fat pads can be identified in CT scans by their radiolucency and distinguished from vacuum phenomenon by measuring their attenuation values. The cause of the intra-articular enlargement of the fat pads is unknown, but it is suggested that their extension into the middle third of the joint may be secondary to degenerative change in the motion segment with capsular laxity in the affected joint. (orig.)

  10. Development of charged particle nuclear reaction data retrieval system on IntelligentPad

    International Nuclear Information System (INIS)

    Ohbayashi, Yosihide; Masui, Hiroshi; Aoyama, Shigeyoshi; Kato, Kiyoshi; Chiba, Masaki

    1999-01-01

    An newly designed database retrieval system of charged particle nuclear reaction database system is developed with IntelligentPad architecture. We designed the network-based (server-client) data retrieval system, and a client system constructs on Windows95, 98/NT with IntelligentPad. We set the future aim of our database system toward the 'effective' use of nuclear reaction data: I. 'Re-produce, Re-edit, Re-use', II. 'Circulation, Evolution', III. 'Knowledge discovery'. Thus, further developments are under way. (author)

  11. A Comparison of PECS and iPad to Teach Requesting to Pre-schoolers with Autistic Spectrum Disorders.

    Science.gov (United States)

    Agius, May M; Vance, Margaret

    2016-01-01

    Few studies have compared the efficacy of the Picture Exchange Communication System (PECS) and iPads used as speech generating devices (SGDs), and none have targeted preschoolers. This study compares the relative efficacy of PECS and an iPad/SGD with three preschool-aged children with autism spectrum disorder and limited functional speech who lived in Malta. The study utilized an adapted alternating treatment design embedded in a multiple baseline design, with requesting of reinforcers as the dependent variable. Visual analysis of the results indicated that all participants required more prompted trials and sessions for the iPad/SGD condition. All participants learned a three step navigational sequence on the iPad. Participant preference probes were inconclusive and were not linked to speed of acquisition of requesting skills. Results suggest that both PECS and an iPad could be appropriate for teaching requesting skills to beginning communicators.

  12. Quantum mutual information and the one-time pad

    International Nuclear Information System (INIS)

    Schumacher, Benjamin; Westmoreland, Michael D.

    2006-01-01

    Alice and Bob share a correlated composite quantum system AB. If AB is used as the key for a one-time pad cryptographic system, we show that the maximum amount of information that Alice can send securely to Bob is the quantum mutual information of AB

  13. One-Time Pad as a nonlinear dynamical system

    Science.gov (United States)

    Nagaraj, Nithin

    2012-11-01

    The One-Time Pad (OTP) is the only known unbreakable cipher, proved mathematically by Shannon in 1949. In spite of several practical drawbacks of using the OTP, it continues to be used in quantum cryptography, DNA cryptography and even in classical cryptography when the highest form of security is desired (other popular algorithms like RSA, ECC, AES are not even proven to be computationally secure). In this work, we prove that the OTP encryption and decryption is equivalent to finding the initial condition on a pair of binary maps (Bernoulli shift). The binary map belongs to a family of 1D nonlinear chaotic and ergodic dynamical systems known as Generalized Luröth Series (GLS). Having established these interesting connections, we construct other perfect secrecy systems on the GLS that are equivalent to the One-Time Pad, generalizing for larger alphabets. We further show that OTP encryption is related to Randomized Arithmetic Coding - a scheme for joint compression and encryption.

  14. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  15. Finger pad friction and its role in grip and touch.

    Science.gov (United States)

    Adams, Michael J; Johnson, Simon A; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-03-06

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick-slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function.

  16. Review of Tour of the Nile [iPad App

    Directory of Open Access Journals (Sweden)

    Helen Strudwick

    2013-07-01

    Full Text Available A review of the iPad app, Tour of the Nile. The app promises 'a virtual journey along the Nile Valley' plus the chance to 'handle' objects through the technology of augmented reality.

  17. Professional Development for iPad Integration in General Education: Staying Ahead of the Curve

    Science.gov (United States)

    Psiropoulos, Dmitri; Barr, Sandy; Eriksson, Claire; Fletcher, Shauna; Hargis, Jace; Cavanaugh, Cathy

    2016-01-01

    This faculty development case study focuses on a team of 16 General Education faculty at an urban women's college during the initial 6 months of the college's comprehensive implementation of an iPad teaching and learning environment. This article traces the effectiveness of an iPad professional development program through analyses of critical…

  18. Antero-posterior (AP) pelvis x-ray imaging on a trolley: Impact of trolley design, mattress design and radiographer practice on image quality and radiation dose

    International Nuclear Information System (INIS)

    Tugwell, J.R.; England, A.; Hogg, P.

    2017-01-01

    Introduction: Physical and technical differences exist between imaging on an x-ray tabletop and imaging on a trolley. This study evaluates how trolley imaging impacts image quality and radiation dose for an antero-posterior (AP) pelvis projection whilst subsequently exploring means of optimising this imaging examination. Methods: An anthropomorphic pelvis phantom was imaged on a commercially available trolley under various conditions. Variables explored included two mattresses, two image receptor holder positions, three source to image distances (SIDs) and four mAs values. Image quality was evaluated using relative visual grading analysis with the reference image acquired on the x-ray tabletop. Contrast to noise ratio (CNR) was calculated. Effective dose was established using Monte Carlo simulation. Optimisation scores were derived as a figure of merit by dividing effective dose with visual image quality scores. Results: Visual image quality reduced significantly (p < 0.05) whilst effective dose increased significantly (p < 0.05) for images acquired on the trolley using identical acquisition parameters to the reference image. The trolley image with the highest optimisation score was acquired using 130 cm SID, 20 mAs, the standard mattress and platform not elevated. A difference of 12.8 mm was found between the image with the lowest and highest magnification factor (18%). Conclusion: The acquisition parameters used for AP pelvis on the x-ray tabletop are not transferable to trolley imaging and should be modified accordingly to compensate for the differences that exist. Exposure charts should be developed for trolley imaging to ensure optimal image quality at lowest possible dose. - Highlights: • Acquisition parameters used for AP pelvis imaging on a trolley need adapting from those used on the x-ray tabletop. • Radiation dose significantly increases for trolley imaging. • An increase in SID can reduce radiation dose and magnification for trolley imaging

  19. Calculation of light delay for coupled microrings by FDTD technique and Padé approximation.

    Science.gov (United States)

    Huang, Yong-Zhen; Yang, Yue-De

    2009-11-01

    The Padé approximation with Baker's algorithm is compared with the least-squares Prony method and the generalized pencil-of-functions (GPOF) method for calculating mode frequencies and mode Q factors for coupled optical microdisks by FDTD technique. Comparisons of intensity spectra and the corresponding mode frequencies and Q factors show that the Padé approximation can yield more stable results than the Prony and the GPOF methods, especially the intensity spectrum. The results of the Prony method and the GPOF method are greatly influenced by the selected number of resonant modes, which need to be optimized during the data processing, in addition to the length of the time response signal. Furthermore, the Padé approximation is applied to calculate light delay for embedded microring resonators from complex transmission spectra obtained by the Padé approximation from a FDTD output. The Prony and the GPOF methods cannot be applied to calculate the transmission spectra, because the transmission signal obtained by the FDTD simulation cannot be expressed as a sum of damped complex exponentials.

  20. Investigation on laser welding characteristics for appendage of bearing pads of nuclear fuel element

    International Nuclear Information System (INIS)

    Kim, S. S.; Kim, W. K.; Park, C. H.; Ko, J. H.; Lee, J. W.; Yang, M. S.

    2001-01-01

    In CANDU nuclear fuel manufacturing the brazing technology has been adopted conventionally to attach the bearing pads of nuclear fuel elements. However, in order to meet good performance of nuclear fuel and improved working efficiency, we started developing the laser welding technology for attachments of the bearing pads. Since the YAG laser can be suitable for small parts and transmit the beam through the optical fiber, the process is corresponding to mass-production with working shops. Making the most of this feature, we have developed the laser welding for appendage of the bearing pads of nuclear fuel elements, and has studied on the laser welding characterisitcs of appendages for nuclear fuel element