WorldWideScience

Sample records for mattress flammability standard

  1. 16 CFR 1632.5 - Mattress pad test procedure.

    Science.gov (United States)

    2010-01-01

    ... 1632.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS... substrate. (b) Flame resistant mattress pads. The following additional requirements shall be applicable to mattress pads which contain a chemical fire retardant. (1) These mattress pads shall be tested in...

  2. 16 CFR 423.9 - Conflict with flammability standards.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Conflict with flammability standards. 423.9... TEXTILE WEARING APPAREL AND CERTAIN PIECE GOODS AS AMENDED § 423.9 Conflict with flammability standards. If there is a conflict between this regulation and any regulations issued under the Flammable Fabrics...

  3. The Impact of Legislation on Gas Can- and Mattress-Related Burn Injuries.

    Science.gov (United States)

    Kellogg, Levi; Butcher, Brandon; Peek-Asa, Corinne; Wibbenmeyer, Lucy

    2018-01-01

    Burn prevention program success requires thorough evaluation of intervention outcomes. The impact of 2 engineering-specific burn prevention regulations, the Children's Gasoline Burn Prevention Act and the Standard for the Flammability of Mattress Sets, will be assessed. Records from 1997 to 2015 within the Consumer Product Safety Commission's (CPSC) National Electronic Injury Surveillance System (NEISS) were reviewed. After identifying gas can- and mattress-involved burn injuries, injury incidence was estimated by utilizing survey sampling weights associated with each record. Logistic regression, incorporating estimated injury incidence and adjusting for gender and age, was performed to test for change in injury risk following these regulations. Within NEISS, there were 493 burns involving gas cans, yielding an estimated 19,339 injuries (95% confidence interval [CI], 15,781-22,896) during the 19-year study period. The odds of a gas can burn injury after legislation decreased by 67% for children younger than 5 years (odds ratio [OR], 0.33; 95% CI, 0.16-0.66; P = 0.0018). There was no significant change in risk for persons 5 years and older (OR, 1.07; 95% CI, 0.80-1.41; P = 0.66). During the same time, there were 219 NEISS burns involving mattresses, yielding an estimated 6864 injuries (95% CI, 5071-8658). The odds of a mattress burn injury following legislation enactment decreased by 31% for all ages (OR, 0.69; 95% CI, 0.51-0.94; P = 0.02). Both regulations decreased the odds of injury in their target populations. This study demonstrates that passive interventions involving engineering standards remain a powerful tool for burn prevention and should be the focus of future efforts to improve burn care.

  4. 76 FR 59014 - Standard for the Flammability of Mattresses and Mattress Pads; Technical Amendment

    Science.gov (United States)

    2011-09-23

    ... of the Standard; rather, SRM usage ensures continuity of a reliably high PFLB with low variability in... demonstrates that the PFLB performance of commercial cigarettes is subject to significant variability that can... industry has sufficient test data to support the hypothesis that RIP cigarettes consistently self...

  5. 16 CFR 1632.1 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... resilient material used alone or in combination with other products intended or promoted for sleeping upon... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE... mattresses, day bed mattresses, roll-a-way bed mattresses, high risers, and trundle bed mattresses. See...

  6. Does a foamy-block mattress system prevent pressure sores ? A prospective randomised clinical trial in 1729 patients.

    Science.gov (United States)

    Berthe, J V; Bustillo, A; Mélot, C; de Fontaine, S

    2007-01-01

    Pressure ulcers are a frequent complication of bed rest. The development of an efficient and low cost pressure relieving system for the prevention of bed-sores would be of considerable hospital health and economic interest. Our study was designed to determine the effectiveness in pressure-sore prevention of an interface pressure-decreasing mattress, the Kliniplot mattress, used in our institution since 1978. In a prospective randomised controlled 7-month clinical trial we compared the Kliniplot mattress with our standard hospital mattress in 1729 patients admitted to medical and surgical departments (neurology, cardiology, oncology-haematology, neurosurgery, thoracic surgery and orthopaedic surgery). Two groups (Klinipot mattress and standard hospital mattress) were monitored for the prevention of pressure sores. The patients were evaluated on a daily basis from their admission until the eventual occurrence of a bed-sore. Patients' characteristics and pressure-sore risk factors were similar at the baseline in both groups. Patients presenting with a pressure sore at the time of admission were excluded. Forty-two of the 1729 patients (2.4%) who entered the study developed at least one pressure sore. Twenty-one of the 657 patients (3.2%) nursed on the Kliniplot mattress, and 21 of the 1072 patients (1.9%) on the standard mattress developed bed-sores (p = 0.154). The median time for the occurrence of pressure sores was 31 days (range 6-87) with the Kliniplot mattress and 18 days (range 2 to 38) with the standard mattress (p sores using the modified Ek's scale were no different at the baseline between both groups (p = 0.764). The severity of the pressure sores was no different between both groups (p = 0.918). Our results show that the occurrence of pressure sores is not reduced but is delayed when patients are nursed on a Kliniplot pressure-decreasing mattress.

  7. 75 FR 67047 - Standard for the Flammability of Mattresses and Mattress Pads

    Science.gov (United States)

    2010-11-01

    ... upholstery fabric manufacturers. Response: As discussed in greater detail in the preliminary regulatory... Environmental Quality regulations and CPSC procedures for environmental review, the Commission has assessed the...

  8. 21 CFR 880.5560 - Temperature regulated water mattress.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temperature regulated water mattress. 880.5560... Therapeutic Devices § 880.5560 Temperature regulated water mattress. (a) Identification. A temperature regulated water mattress is a device intended for medical purposes that consists of a mattress of suitable...

  9. Trial of a novel plasma gas disinfection system (Radica) to reduce mattress residual bacterial contamination in the acute hospital setting: a preliminary study.

    Science.gov (United States)

    Shiely, F; Fallon, D; Casey, C; Kerins, D M; Eustace, J A

    2017-02-01

    In routine clinical practice, mattresses are manually cleaned using specialised cleaning and high-level disinfecting fluids. While effective against a wide range of organisms, the success of this approach is dependent on a thorough and complete application and is likely to be susceptible to human error and thus variable. The efficacy of available infection control measures to reduce such mattress contamination is unknown as it is not subject to quality control measures. There is a pressing need to identify more effective methods to prevent cross contamination within the medical environment, given the lack of available treatment strategies. The purpose of this study is to investigate the ability of a new technology, gaseous technology, to reduce colonization levels, compared to standard cleaning, and so attenuate superficial nosocomial infections. We conducted a prospective, single-centre, open-label, non-randomized trial with blinded outcome assessments, comparing the standard cleaning of hospital mattresses with a novel plasma based disinfection system Radica™, followed by a standard post-cleaning culturing protocol (five swabs/mattress). The median (interquartile range) maximal colony count per mattress for the 20 Radica versus 7 routinely cleaned mattresses was 1 (1-2.7) versus Too-Numerous-to-Count (TNTC) (32-TNTC), respectively, p = 0.002. Of the 20 Radica™ treated mattresses, 12 (60 %) had no positive culture result while all of the standard cleaned mattresses had at least two positive cultures. The plasma based Radica disinfection system reduces mattress bacterial colonization levels as compared to routine cleaning. This is a potentially important technology in the health care system to reduce surface colonisation and hence nosocomial infections.

  10. The impact of compliant surfaces on in-hospital chest compressions: effects of common mattresses and a backboard.

    NARCIS (Netherlands)

    Noordergraaf, G.J.; Paulussen, I.W.; Venema, A.; Berkom, P.F. van; Woerlee, P.H.; Scheffer, G.J.; Noordergraaf, A.

    2009-01-01

    PURPOSE: To evaluate, in a hospital setting, the influence of different, common mattresses, with and without a backboard, on chest movement during CPR. DESIGN AND SETTING: Sixty CPR sessions (140s each, 30:2, C:R ratio 1:1) were performed using a manikin on standard hospital mattresses, with or

  11. Esprit HR mattress cover in pressure ulcer prevention.

    Science.gov (United States)

    Khoulowa, J

    Modern mattresses provide soft dense foam, which permits the redistribution of pressure on the patient over a wider area - away from bony prominences where pressure ulcers usually occur. The material used in producing multistretch covers for the new mattresses had a tendency to delaminate as a result of a combination of heat, moisture and inappropriate cleansing techniques causing the water barriers to fall. In partnership with York Health NHS Trust and the material manufacturer, STM Healthcare produced a mattress cover (Esprit HR) which was able to withstand higher pressure from heat and moisture and greatly extended the life expectancy of the Esprit HR mattress.

  12. 75 FR 5578 - Submission for OMB Review; Comment Request-Flammability Standards for Clothing Textiles and Vinyl...

    Science.gov (United States)

    2010-02-03

    ... Standards for Clothing Textiles and Vinyl Plastic Film AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: Pursuant to the Paperwork Reduction Act of 1995 (44 U.S.C. Chapter 35), the Consumer... Commission's flammability standards for clothing textiles and vinyl plastic film. DATES: Written comments on...

  13. 16 CFR 1632.31 - Mattresses/mattress pads-labeling, recordkeeping, guaranties and “one of a kind” exemption.

    Science.gov (United States)

    2010-01-01

    ...) Products intended for one time use (see § 1632.5(b)(1)(i)) are not subject to the requirements of... description of each mattress or mattress pad prototype with an assigned prototype identification number. (2) Test results and details of each prototype test performed in accordance with § 1632.4 or § 1632.5...

  14. The provision of therapy mattresses for pressure ulcer prevention.

    Science.gov (United States)

    Pagnamenta, Fania

    2017-03-23

    Preventing pressure ulcers is complex and involves skin care, the provision of therapy mattresses, repositioning, the management of incontinence and adequate nutritional support. This article describes a model of therapy mattress provision that is based on non-powered products. Evaluating the efficiency of this model is challenging, due to the complexities of care, but Safety Thermometer data and incidents reports offer reassurance that non-powered therapy mattresses can provide adequate pressure ulcer prevention. Therapy mattress provision is only one of the five interventions and these are described in details to give readers a fuller picture of the model used at the author's trust.

  15. 16 CFR 1632.4 - Mattress test procedure.

    Science.gov (United States)

    2010-01-01

    ... position at a reasonable height for making observations. (ii) If thin flexible mattresses or mattress pads... relative humidity measuring instrument, a thin rod, straight pins, a knife or scissors, and tongs are... (from water bottle), cut around the burning material with a knife or scissors and pull the material out...

  16. 16 CFR 1611.4 - Flammability test.

    Science.gov (United States)

    2010-01-01

    ... FLAMMABILITY OF VINYL PLASTIC FILM The Standard § 1611.4 Flammability test. (a) Apparatus and materials. The.... The center section of the rack contains an open U-shaped area in which burning of the specimen takes... fan is turned off during the test. (4) Timing mechanism. The burning rate shall be determined by a...

  17. Manual cleaning of hospital mattresses: an observational study comparing high- and low-resource settings.

    Science.gov (United States)

    Hopman, J; Hakizimana, B; Meintjes, W A J; Nillessen, M; de Both, E; Voss, A; Mehtar, S

    2016-01-01

    Hospital-associated infections (HAIs) are more frequently encountered in low- than in high-resource settings. There is a need to identify and implement feasible and sustainable approaches to strengthen HAI prevention in low-resource settings. To evaluate the biological contamination of routinely cleaned mattresses in both high- and low-resource settings. In this two-stage observational study, routine manual bed cleaning was evaluated at two university hospitals using adenosine triphosphate (ATP). Standardized training of cleaning personnel was achieved in both high- and low-resource settings. Qualitative analysis of the cleaning process was performed to identify predictors of cleaning outcome in low-resource settings. Mattresses in low-resource settings were highly contaminated prior to cleaning. Cleaning significantly reduced biological contamination of mattresses in low-resource settings (P cleaning in both the high- and low-resource settings seemed comparable. Cleaning with appropriate type of cleaning materials reduced the contamination of mattresses adequately. Predictors for mattresses that remained contaminated in a low-resource setting included: type of product used, type of ward, training, and the level of contamination prior to cleaning. In low-resource settings mattresses were highly contaminated as noted by ATP levels. Routine manual cleaning by trained staff can be as effective in a low-resource setting as in a high-resource setting. We recommend a multi-modal cleaning strategy that consists of training of domestic services staff, availability of adequate time to clean beds between patients, and application of the correct type of cleaning products. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Pyroglyphid mites, xerophilic fungi and allergenic activity in dust from hospital mattresses.

    Science.gov (United States)

    v d Lustgraaf, B; Jorde, W

    1977-12-01

    Dust from mattresses of different composition and age was analysed for mites, xerophilic fungi and allergenic activity. The mites of the genus Demodex were the most abundant (58.2 per cent). Also pyroglyphid mites occurred commonly (36.6 per cent). Pyroglyphid mites were present in small numbers (mean: 1 specimen/0.2 g of dust) in 12 out of the 17 older polyester-foam mattresses. The 11 cotton-horsechair mattresses and the newly used polyester-foam mattresses (three tested) were without them. The dust from the cotton-horsehair mattresses had a significantly higher allergenic activity than from those of polyester-foam. Xerophilic fungi were isolated in three out of 31 mattresses. The species isolated belonged to the genus Aspergillus and Eurotium. E. repens occurred most frequently. Disinfection of mattresses was suggested to have a negative influence on the occurrence of mites and fungi.

  19. The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair: Vertical or Horizontal Mattress?

    Science.gov (United States)

    Montanez, Anthony; Makarewich, Christopher A; Burks, Robert T; Henninger, Heath B

    2016-09-01

    Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Controlled laboratory study. Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the contralateral shoulder received a horizontal mattress. Specimens were mounted in a materials testing machine and tested in uniaxial tensile deformation for cyclic loading (500 cycles at 1 Hz to 1.0 MPa of effective stress), followed by failure testing carried out at a rate of 1 mm/s. Construct gapping and applied loads were monitored continuously throughout the testing. Vertical mattress sutures were placed in 5 right and 4 left shoulders. Peak cyclic gapping did not differ between vertical (mean ± SD, 2.8 ± 1.1 mm) and horizontal mattress specimens (3.0 ± 1.2 mm) (P = .684). Vertical mattress sutures failed at higher loads compared with horizontal mattress sutures (568.9 ± 140.3 vs 451.1 ± 174.3 N; P = .025); however, there was no significant difference in failure displacement (8.0 ± 1.6 vs 6.0 ± 2.1 mm; P = .092). Failure stiffness did not differ between the suture patterns (P = .204). In transosseous-equivalent rotator cuff repairs near the musculotendinous junction, a vertical mattress suture used as the medial stitch

  20. 16 CFR 1633.4 - Prototype testing requirements.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Prototype testing requirements. 1633.4... STANDARD FOR THE FLAMMABILITY (OPEN FLAME) OF MATTRESS SETS The Standard § 1633.4 Prototype testing... three specimens of each prototype to be tested according to § 1633.7 and obtain passing test results...

  1. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Science.gov (United States)

    2010-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  2. Conceptontwerp nieuwe slaapmatten (Concept Design of Sleeping Mattresses)

    Science.gov (United States)

    2008-11-01

    Datum november 2008 Auteur (s) drs. P.A. Reffeltrath ing. M.G. Brandsma M.G.M. Weghorst Rubricering rapport Ongerubriceerd TK9 TNO-rapport...slaapmatten in combinatie met de gegevens van objectieve metingen. In theorie maakt het conceptontwerp het mogelijk om tegen minder gewicht en pakvolume...making a mattress that is lighter, has less packing volume, is more comfortable and more durable than the currently available mattresses. In theory

  3. 16 CFR 1611.3 - Flammability-general requirement.

    Science.gov (United States)

    2010-01-01

    ... STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM The Standard § 1611.3 Flammability—general requirement. The rate of burning shall not exceed 1.2 in./sec as judged by the average of five determinations...

  4. The accumulation of dust mite allergens on mattresses made of different kinds of materials.

    Science.gov (United States)

    Visitsunthorn, Nualanong; Chirdjirapong, Varakorn; Pootong, Visanu; Jirapongsananuruk, Orathai; Pacharn, Punchama; Weeravejsukit, Sirirat; Mahakittikun, Vanna; Vichyanond, Pakit

    2010-01-01

    Different mattress materials may affect the accumulation of allergens. To compare the amount of group 1 dust mite allergens (Der p1 + Der f1) on mattresses made of different kinds of materials before and after use. Sixty new mattresses made of kapok, synthetic fiber, coconut fiber and sponge-like polyurethane, were placed in the house officers' dormitory at Siriraj hospital, Thailand. The dust samples were collected before (0), 1, 2, 3, 6, 9 and 12 months after the mattresses were used. Group 1 dust mite allergens were analyzed using two-site monoclonal antibody ELISA. Der f1 made up 86.7 % of group 1 allergens found in the matress dust. After the 2nd month, only the mean level in sponge-like polyurethane mattress was under 2 microg/g dust (sensitized level). At the 6th month, the mean levels were 13.1 in coconut, 21.7 in kapok and 17.3 microg/g dust in synthetic fiber, all of which were more than 10 microg/g dust (symptomatic level). At the 9th month, the level in sponge-like polyurethane mattress was increased to 11.2 microg/g. At 12th month the level in coconut fiber, sponge-like polyurethane synthetic fiber and kapok mattresses were 20.2, 22.4, 28.9 and 32.2 microg/g dust respectively. The accumulation rate in kapok and synthetic mattresses was significantly higher than coconut and sponge-like polyurethane mattresses. The mean level of group 1 mite allergens exceeded 10 microg/g dust after the 6th month of use in coconut fiber, kapok and synthetic fiber and at the 9th month in sponge-like polyurethane mattress.

  5. Flammability of litter from southeastern trees: a preliminary assessment

    Science.gov (United States)

    J. Morgan Varner; Jeffrey M. Kane; Erin M. Banwell; Jesse K. Kreye

    2015-01-01

    The southeastern United States possesses a great diversity of woody species and an equally impressive history of wildland fires. Species are known to vary in their flammability, but little is known about southeastern species. We used published data and our own collections to perform standard litter flammability tests on a diverse suite of 25 native overstory trees from...

  6. Flammable refrigerants

    NARCIS (Netherlands)

    Gerwen, R.J.M. van; Verwoerd, M.; Oostendorp, P.A.

    1999-01-01

    Hydrocarbons are promising alternatives for CFC, HCFC and HFC refrigerants. Due to their flammable nature, safety aspects have to be considered carefully. The world-wide situation concerning acceptability and practical application of flammable refrigerants is becoming more and more complex and

  7. Warming preterm infants in the delivery room: polyethylene bags, exothermic mattresses or both?

    Science.gov (United States)

    McCarthy, Lisa K; O'Donnell, Colm P F

    2011-12-01

    To compare the admission temperature of infants treated with polyethylene bags alone to infants treated with exothermic mattresses in addition to bags in the delivery room. We prospectively studied infants born at bags at birth. Some infants were also placed on mattresses. Admission axillary temperatures were measured in all infants on admission to the neonatal intensive care. We compared the temperatures of infants treated with bags alone to those treated with mattresses and bags. We studied 43 infants: 15 were treated with bags while 28 were treated with a bag and mattress. Mean admission temperature was similar between the groups. Hypothermia and hyperthermia occurred more frequently in infants treated with a bag and mattress, and more infants treated with a bag had admission temperatures 36.5-37.5°C. The use of exothermic mattresses in addition to polyethylene bags, particularly in younger, smaller newborns, may result in more hypothermia and hyperthermia on admission. A randomised controlled trial is necessary to determine which strategy results in more infants having admission temperatures in the normal range. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.

  8. A retrospective study to determine the incidence of pressure ulcers in burn patients using an alternating pressure mattress.

    Science.gov (United States)

    Still, Joseph M; Wilson, Joan; Rinker, Connie; Law, Edward; Craft-Coffman, Beretta

    2003-08-01

    In immobilized patients, unrelieved pressure can create decubitus ulcers over bony prominences. Those burn patients who require prolonged bed rest, are prone to the development of such problems. Various methods of reducing pressure on these areas, including frequent turning and the use of air fluidized and low air loss beds, have been adopted to attempt to prevent the development of this complication. The Pegasus Renaissance alternating pressure mattress is such a device, intended to reduce the incidence of decubitus ulcers. It was introduced at our burn unit and evaluated over a 29-month period. During the study period, 186 (13.4%) of 1390 acutely burned patients, believed to be at high risk for the development of decubiti, were placed on this mattress. Other patients were treated in the standard hospital bed. Care was otherwise the same. No decubitus ulcers developed in any of the patients treated on the Pegasus Renaissance mattress.

  9. Multi-stage versus single-stage inflation and deflation cycle for alternating low pressure air mattresses to prevent pressure ulcers in hospitalised patients: a randomised-controlled clinical trial.

    Science.gov (United States)

    Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S

    2012-04-01

    The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation

  10. A quantitative analysis of microcirculation in sore-prone pressure areas on conventional and pressure relief hospital mattresses using laser Doppler flowmetry and tissue spectrophotometry.

    Science.gov (United States)

    Rothenberger, Jens; Krauss, Sabrina; Held, Manuel; Bender, Dominik; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Constantinescu, Mihai Adrian; Jaminet, Patrick

    2014-11-01

    Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  11. 46 CFR 105.10-15 - Flammable liquid.

    Science.gov (United States)

    2010-10-01

    ... FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Definition of Terms Used in This Part § 105.10-15 Flammable... vapor pressure of 14 pounds or more. 1 American Society of Testing Materials Standard D 323...

  12. Flammable gas tank safety program: Technical basis for gas analysis and monitoring

    International Nuclear Information System (INIS)

    Sherwood, D.J.

    1995-01-01

    Flammable gases generated in radioactive liquids. Twenty-five high level radioactive liquid waste storage tanks located underground at the Hanford Site are on a Flammable Gas Watch List because they contain waste which tends to retain the gases generated in it until rather large quantities are available for sudden release to the tank head space; if a tank is full it has little dome space, and a flammable concentration of gases could be produced--even if the tank is ventilated. If the waste has no tendency to retain gas generated in it then a continual flammable gas concentration in the tank dome space is established by the gas production rate and the tank ventilation rate (or breathing rate for unventilated tanks); this is also a potential problem for Flammable Gas Watch List tanks, and perhaps other Hanford tanks too. All Flammable Gas Watch List tanks will be fitted with Standard Hydorgen Monitoring Systems so that their behavior can be observed. In some cases, such as tank 241-SY-101, the data gathered from such observations will indicate that tank conditions need to be mitigated so that gas release events are either eliminated or rendered harmless. For example, a mixer pump was installed in tank 241-SY-101; operating the pump stirs the waste, replacing the large gas release events with small releases of gas that are kept below twenty-five percent of the lower flammability limit by the ventilation system. The concentration of hydrogen measured in Hanford waste tanks is greater than that of any other flammable gas. Hydrogen levels measured with a Standard Hydrogen Monitoring System in excess of 0.6 volume percent will cause Westinghouse Hanford Company to consider actions which will decrease the amount of flammable gas in the tank

  13. Sterilization using ozone-ion gas sterilization using ozone-ion gas for mattresses used by the elderly; Ozone ion kunjoho ni kansuru kenkyu. Ozone ion kunjoho no zaitaku kaigoyo mattress mekkin eno oyo

    Energy Technology Data Exchange (ETDEWEB)

    Mikami, H.; Suzuki, A.; Hamasaki, H. [Shinryo Corp., Tokyo (Japan); Ishikawa, S.; Miyata, M.; Nanba, T. [Kitasato Univ., Tokyo (Japan); Sueyoshi, K. [Mitsubishi Research Institute Inc., Tokyo (Japan)

    1999-05-25

    The new generation of Japanese is facing an aging society: the number of young people is decreasing dramatically, while the number of elderly is increasing. Consequently, care for the elderly has become a big problem. One particular problem area we`ve investigated is the use of unclean mattresses by the bedridden elderly. These mattresses provide an all too excellent environments for the growth of microbes. We measured the density of microbes on the cover of mattresses at 775cfu/cm{sup 2} and in the bed filling at 136cfu/g. The dominant species of microbes were MRSA and Bacillus. We used MRSA, Bacillus subtilis and Escherichia coli as biological indicators and tested whether our system using ozone-ion fumigants was applicable for sterilization of mattresses. The survival ratio of MRSA were 10{sup -8} {approx} 10{sup -9}, 10{sup -7} {approx} 10{sup -8} for B. subtilis and below 10{sup -8} for E. coli. These experiments made it clear that our system is applicable for sterilization of the mattresses used by bedfast elderly. (author)

  14. Evaluation of free-stall mattress bedding treatments to reduce mastitis bacterial growth

    Energy Technology Data Exchange (ETDEWEB)

    Kristula, M A; Dou, Z; Toth, J D; Smith, B I; Harvey, N; Sabo, M [University of Penn, Kennett Square, PA (United States)

    2008-05-15

    Bacterial counts were compared in free-stall mattresses and teat ends exposed to 5 treatments in a factorial study design on 1 dairy farm. Mattresses in five 30-cow groups were subjected to 1 of 5 bedding treatments every other day: 0.5 kg of hydrated limestone, 120 mL of commercial acidic conditioner, 1 kg of coal fly ash, 1 kg of kiln-dried wood shavings, and control (no bedding). Counts of coliforms, Klebsiella spp., Escherichia coli, and Streptococcus spp. were lowest on mattresses bedded with lime. Mattresses bedded with the commercial acidic conditioner had the next lowest counts for coliforms, Klebsiella spp., and Streptococcus spp. Wood shavings and the no-bedding control had the highest counts for coliform and Klebsiella spp. Compared with wood shavings or control, fly ash reduced the counts of coliforms, whereas for the other 3 bacterial groups, the reduction was not always significant. Streptococcus spp. counts were greatest in the control group and did not differ among the shavings and fly ash groups. Teat swab results indicated that hydrated lime was the only bedding treatment that significantly decreased the counts of both coliforms and Klebsiella spp. There were no differences in Streptococcus spp. numbers on the teats between any of the bedding treatments. Bacterial populations grew steadily on mattresses and were generally higher at 36 to 48 h than at 12 to 24 h, whereas bacterial populations on teats grew rapidly by 12 h and then remained constant. Hydrated lime was the only treatment that significantly reduced bacterial counts on both mattresses and teat ends, but it caused some skin irritation.

  15. Bedding on geotextile mattresses: how much is needed to improve cow comfort?

    Science.gov (United States)

    Tucker, C B; Weary, D M

    2004-09-01

    The objective of our study was to evaluate how the amount of sawdust bedding on mattresses affects dairy cattle behavior and preferences. Eleven nonlactating, multiparous cows were housed individually in pens with access to 3 free stalls. Each stall was fitted with a geotextile mattress covered with either 0, 1, or 7.5 kg of kiln-dried sawdust. The experiment began with 7 d of acclimatization to all 3 stalls. Cows were then allowed access to only 1 of the 3 stalls at a time, each for 3 d (restriction phase). At the end of this restriction phase, cows were allowed free access to all 3 stalls for 3 d (free-choice phase). Time spent lying and the number of lying bouts increased significantly with the amount of bedding, from 12.3 +/- 0.53 h lying and 8.5 +/- 0.62 bouts per 24 h on bare mattresses to 13.8 +/- 0.53 h lying and 10.0 +/- 0.62 bouts per 24 h on mattresses with 7.5 kg of sawdust. In addition, the animals spent less time standing with only the front hooves in the stalls when more sawdust was present. When allowed free access to all 3 options, all 11 animals spent a majority of their time lying and standing in the 7.5-kg option. In conclusion, cows preferred mattresses bedded with 7.5 kg of sawdust, on which they spent more time lying down and less time standing with only the front hooves in stalls. These results indicate that more sawdust bedding improves cow comfort in stalls with geotextile mattresses.

  16. Clothing Flammability and Burn Injuries: Public Opinion Concerning an Overlooked, Preventable Public Health Problem.

    Science.gov (United States)

    Frattaroli, Shannon; Spivak, Steven M; Pollack, Keshia M; Gielen, Andrea C; Salomon, Michele; Damant, Gordon H

    2016-01-01

    The objective of this study was to describe knowledge of clothing flammability risk, public support for clothing flammability warning labels, and stronger regulation to reduce the risk. As part of a national survey of homeowners about residential sprinkler systems, the authors included questions about clothing flammability. The authors used an online web panel to sample homeowners and descriptive methods to analyze the resulting data. The sample included 2333 homeowners. Knowledge of clothing flammability and government oversight of clothing flammability risk was low. Homeowners were evenly split about the effectiveness of current standards; however, when presented with clothing-related burn injury and death data, a majority (53%) supported stricter standards. Most homeowners (64%) supported warning labels and indicated that such labels would either have no effect on their purchasing decisions (64%) or be an incentive (24%) to purchase an item. Owners of sprinkler-equipped homes were more likely to support these interventions than owners of homes without sprinkler systems. Public knowledge about clothing flammability risks is low. Most homeowners supported clothing labels to inform consumers of this risk and increased government intervention to reduce the risk.

  17. Flammability Indices for Refrigerants

    Science.gov (United States)

    Kataoka, Osami

    This paper introduces a new index to classify flammable refrigerants. A question on flammability indices that ASHRAE employs arose from combustion test results of R152a and ammonia. Conventional methods of not only ASHRAE but also ISO and Japanese High-pressure gas safety law to classify the flammability of refrigerants are evaluated to show why these methods conflict with the test results. The key finding of this paper is that the ratio of stoichiometric concentration to LFL concentration (R factor) represents the test results most precisely. In addition, it has excellent correlation with other flammability parameters such as flame speed and pressure rise coefficient. Classification according to this index gives reasonable flammability order of substances including ammonia, R152a and carbon monoxide. Theoretical background why this index gives good correlation is also discussed as well as the insufficient part of this method.

  18. A retrospective study to determine the incidence of pressure ulcers in burn patients using a low air loss pressure relieving mattress.

    Science.gov (United States)

    Still, Joseph M; Wilson, Joan; Rinker, Connie; Law, Edward; Craft-Coffman, Beretta

    2003-06-01

    In immobilized patients, unrelieved pressure can create decubitus ulcers over bony prominences. Those burn patients who require prolonged bed rest, are prone to the development of such problems. Various methods of reducing pressure on these areas, including frequent turning and the use of air fluidized and low air loss beds, have been adopted to attempt to prevent the development of this complication. The Pegasus Renaissance alternating pressure mattress is such a device, intended to reduce the incidence of decubitus ulcers. It was introduced at our burn unit and evaluated over a 29-month period. During the study period, 186 (13.4%) of 1390 acutely burned patients, believed to be at high risk for the development of decubiti, were placed on this mattress. Other patients were treated in the standard hospital bed. Care was otherwise the same. No decubitus ulcers developed in any of the patients treated on the Pegasus Renaissance mattress.

  19. Methodology for flammable gas evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, J.D., Westinghouse Hanford

    1996-06-12

    There are 177 radioactive waste storage tanks at the Hanford Site. The waste generates flammable gases. The waste releases gas continuously, but in some tanks the waste has shown a tendency to trap these flammable gases. When enough gas is trapped in a tank`s waste matrix, it may be released in a way that renders part or all of the tank atmosphere flammable for a period of time. Tanks must be evaluated against previously defined criteria to determine whether they can present a flammable gas hazard. This document presents the methodology for evaluating tanks in two areas of concern in the tank headspace:steady-state flammable-gas concentration resulting from continuous release, and concentration resulting from an episodic gas release.

  20. 16 CFR 1500.44 - Method for determining extremely flammable and flammable solids.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Method for determining extremely flammable and flammable solids. 1500.44 Section 1500.44 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS HAZARDOUS SUBSTANCES AND ARTICLES; ADMINISTRATION AND...

  1. Research on the relationship between the structural properties of bedding layer in spring mattress and sleep quality.

    Science.gov (United States)

    Shen, Liming; Chen, Yu-xia; Guo, Yong; Zhong, ShiLu; Fang, Fei; Zhao, Jing; Hu, Tian-Yi

    2012-01-01

    Mattress, as a sleep platform, its types and physical properties has an important effect on sleep quality and rest efficiency. In this paper, by subjective evaluations, analysis of sleeping behaviors and tests of depth of sleep, the relationship between characteristics of the bedding materials, the structure of mattress, sleep quality and sleep behaviors were studied. The results showed that: (1) Characteristics of the bedding materials and structure of spring mattress had a remarkable effect on sleep behaviors and sleep quality. An optimum combination of the bedding materials, the structure of mattress and its core could improve the overall comfort of mattress, thereby improving the depth of sleep and sleep quality. (2) Sleep behaviors had a close relationship with sleeping postures and sleep habits. The characteristics of sleep behaviors vary from person to person.

  2. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Hu, T.A.

    2007-01-01

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The methodology of flammability analysis for Hanford tank waste is developed. The hydrogen generation rate model was applied to calculate the gas generation rate for 177 tanks. Flammability concentrations and the time to reach 25% and 100% of the lower flammability limit, and the minimum ventilation rate to keep from 100 of the LFL are calculated for 177 tanks at various scenarios.

  3. Flammability characteristics of LPG

    International Nuclear Information System (INIS)

    Cardillo, Paolo

    2005-01-01

    The use of LPG is continuous increase not only in the domestic field but also in the field of the transports. Consequently, there is a renewed interest for its flammability characteristics in order to decide the necessary conditions of safety. The main components of LPG are hydrocarbons containing three or four carbon atoms. The normal components of LPG are propane and butane; small concentrations of other hydrocarbons (isobutene, propylene, butane, ethane, pentane) may also be present. Different mixtures of LGP have different and physical characteristics with a different behavior during the use. Also flammability characteristics can be different according to the composition. In this paper at firsts the flammability characteristics of the main components of LGP, taken singularly, are examinated; subsequently some examples of calculation of the flammability limits of different mixture are reported [it

  4. Use of backboard and deflation improve quality of chest compression when cardiopulmonary resuscitation is performed on a typical air inflated mattress configuration.

    Science.gov (United States)

    Oh, Jaehoon; Kang, Hyunggoo; Chee, Youngjoon; Lim, Taeho; Song, Yeongtak; Cho, Youngsuk; Je, Sangmo

    2013-02-01

    No study has examined the effectiveness of backboards and air deflation for achieving adequate chest compression (CC) depth on air mattresses with the typical configurations seen in intensive care units. To determine this efficacy, we measured mattress compression depth (MCD, mm) on these surfaces using dual accelerometers. Eight cardiopulmonary resuscitation providers performed CCs on manikins lying on 4 different surfaces using a visual feedback system. The surfaces were as follows: A, a bed frame; B, a deflated air mattress placed on top of a foam mattress laid on a bed frame; C, a typical air mattress configuration with an inflated air mattress placed on a foam mattress laid on a bed frame; and D, C with a backboard. Deflation of the air mattress decreased MCD significantly (B; 14.74 ± 1.36 vs C; 30.16 ± 3.96, P deflation of the air mattress decreased MCD more than use of a backboard (B; 14.74 ± 1.36 vs D; 25.46 ± 2.89, P = 0.002). The use of a both a backboard and a deflated air mattress in this configuration reduces MCD and thus helps achieve accurate CC depth during cardiopulmonary resuscitation.

  5. Flammable gas tank safety program: Technical basis for gas analysis and monitoring

    International Nuclear Information System (INIS)

    Estey, S.D.

    1998-01-01

    Several Hanford waste tanks have been observed to exhibit periodic releases of significant quantities of flammable gases. Because potential safety issues have been identified with this type of waste behavior, applicable tanks were equipped with instrumentation offering the capability to continuously monitor gases released from them. This document was written to cover three primary areas: (1) describe the current technical basis for requiring flammable gas monitoring, (2) update the technical basis to include knowledge gained from monitoring the tanks over the last three years, (3) provide the criteria for removal of Standard Hydrogen Monitoring System(s) (SHMS) from a waste tank or termination of other flammable gas monitoring activities in the Hanford Tank farms

  6. Matrigel Mattress: A Method for the Generation of Single Contracting Human-Induced Pluripotent Stem Cell-Derived Cardiomyocytes.

    Science.gov (United States)

    Feaster, Tromondae K; Cadar, Adrian G; Wang, Lili; Williams, Charles H; Chun, Young Wook; Hempel, Jonathan E; Bloodworth, Nathaniel; Merryman, W David; Lim, Chee Chew; Wu, Joseph C; Knollmann, Björn C; Hong, Charles C

    2015-12-04

    The lack of measurable single-cell contractility of human-induced pluripotent stem cell-derived cardiac myocytes (hiPSC-CMs) currently limits the utility of hiPSC-CMs for evaluating contractile performance for both basic research and drug discovery. To develop a culture method that rapidly generates contracting single hiPSC-CMs and allows quantification of cell shortening with standard equipment used for studying adult CMs. Single hiPSC-CMs were cultured for 5 to 7 days on a 0.4- to 0.8-mm thick mattress of undiluted Matrigel (mattress hiPSC-CMs) and compared with hiPSC-CMs maintained on a control substrate (method enables the rapid generation of robustly contracting hiPSC-CMs and enhances maturation. This new method allows quantification of contractile performance at the single-cell level, which should be valuable to disease modeling, drug discovery, and preclinical cardiotoxicity testing. © 2015 American Heart Association, Inc.

  7. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Meacham, J.E.

    2008-01-01

    This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for al1 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 13 days for DSTs (i.e., tank 241-AZ-102) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 12 days for DSTs (i.e., tank 241-AZ-102) and 34 days for SSTs (i.e., tank 241-B-203).

  8. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Meacham, J.E.

    2009-01-01

    This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for all 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 11 days for DSTs (i.e., tank 241-AZ-10l) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 10 days for DSTs (i.e., tank 241-AZ-101) and 34 days for SSTs (i.e., tank 241-B-203).

  9. Food allergens in mattress dust in Norwegian homes - a potentially important source of allergen exposure.

    Science.gov (United States)

    Bertelsen, R J; Faeste, C K; Granum, B; Egaas, E; London, S J; Carlsen, K-H; Lødrup Carlsen, K C; Løvik, M

    2014-01-01

    Sensitization to food allergens and food allergic reactions are mostly caused by ingesting the allergen, but can also occur from exposure via the respiratory tract or the skin. Little is known about exposure to food allergens in the home environment. The objective of this study was firstly to describe the frequency of detection of allergens from fish, egg, milk, and peanut in mattress dust collected from homes of 13-year-old adolescents and secondly to identify home characteristics associated with the presence of food allergen contamination in dust. Food allergens were measured by dot blot analysis in mattress dust from 143 homes in Oslo, Norway. We analysed associations between home characteristics (collected by parental questionnaires and study technicians) and food allergens by multivariate regression models. Fish allergen was detected in 46%, peanut in 41%, milk in 39%, and egg allergen in 22% of the mattress dust samples; only three samples contained none of these allergens. All four food allergens were more frequently detected in mattresses in small dwellings (Food allergens occurred frequently in beds in Norwegian homes, with dwelling size and proximity of kitchen and bedroom as the most important determinants. Due to the amount of time children spent in the bedroom, mattress dust may be an important source of exposure to food allergens. © 2013 John Wiley & Sons Ltd.

  10. Microcontrolled air-mattress for ulcer by pressure prevention

    Science.gov (United States)

    Pasluosta, Cristian F.; Fontana, Juan M.; Beltramone, Diego A.; Taborda, Ricardo A. M.

    2007-11-01

    An ulcer by pressure is produced when a constant pressure is exerted over the skin. This generates the collapse of the blood vessels and, therefore, a lack in the contribution of the necessary nutrients for the affected zone. As a consequence, the skin deteriorates, eventually causing an ulcer. In order to prevent it, a protocol must be applied to the patient, which is reflected on time and cost of treatment. There are some air mattresses available for this purpose, but whose performance does not fulfill all requirements. The prototype designed in our laboratory is based on the principle of the air mattress. Its objective is to improve on existing technologies and, due to an increased automation, reduce time dedication for personnel in charge of the patient. A clinical experience was made in the local Emergencies Hospital and also in an institution dedicated to aged patients care. In both cases, the results obtained and the comments from the personnel involved were favorable.

  11. Microcontrolled air-mattress for ulcer by pressure prevention

    International Nuclear Information System (INIS)

    Pasluosta, Cristian F; Fontana, Juan M; Beltramone, Diego A; Taborda, Ricardo A M

    2007-01-01

    An ulcer by pressure is produced when a constant pressure is exerted over the skin. This generates the collapse of the blood vessels and, therefore, a lack in the contribution of the necessary nutrients for the affected zone. As a consequence, the skin deteriorates, eventually causing an ulcer. In order to prevent it, a protocol must be applied to the patient, which is reflected on time and cost of treatment. There are some air mattresses available for this purpose, but whose performance does not fulfill all requirements. The prototype designed in our laboratory is based on the principle of the air mattress. Its objective is to improve on existing technologies and, due to an increased automation, reduce time dedication for personnel in charge of the patient. A clinical experience was made in the local Emergencies Hospital and also in an institution dedicated to aged patients care. In both cases, the results obtained and the comments from the personnel involved were favorable

  12. Microcontrolled air-mattress for ulcer by pressure prevention

    Energy Technology Data Exchange (ETDEWEB)

    Pasluosta, Cristian F; Fontana, Juan M; Beltramone, Diego A; Taborda, Ricardo A M [Universidad Nacional de Cordoba. Cordoba (Argentina)

    2007-11-15

    An ulcer by pressure is produced when a constant pressure is exerted over the skin. This generates the collapse of the blood vessels and, therefore, a lack in the contribution of the necessary nutrients for the affected zone. As a consequence, the skin deteriorates, eventually causing an ulcer. In order to prevent it, a protocol must be applied to the patient, which is reflected on time and cost of treatment. There are some air mattresses available for this purpose, but whose performance does not fulfill all requirements. The prototype designed in our laboratory is based on the principle of the air mattress. Its objective is to improve on existing technologies and, due to an increased automation, reduce time dedication for personnel in charge of the patient. A clinical experience was made in the local Emergencies Hospital and also in an institution dedicated to aged patients care. In both cases, the results obtained and the comments from the personnel involved were favorable.

  13. Flammable gas project topical report

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.D.

    1997-01-29

    The flammable gas safety issue was recognized in 1990 with the declaration of an unreviewed safety question (USQ) by the U. S. Department of Energy as a result of the behavior of the Hanford Site high-level waste tank 241-SY-101. This tank exhibited episodic releases of flammable gas that on a couple of occasions exceeded the lower flammability limit of hydrogen in air. Over the past six years there has been a considerable amount of knowledge gained about the chemical and physical processes that govern the behavior of tank 241-SY-1 01 and other tanks associated with the flammable gas safety issue. This report was prepared to provide an overview of that knowledge and to provide a description of the key information still needed to resolve the issue. Items covered by this report include summaries of the understanding of gas generation, retention and release mechanisms, the composition and flammability behavior of the gas mixture, the amounts of stored gas, and estimated gas release fractions for spontaneous releases. `Me report also discusses methods being developed for evaluating the 177 tanks at the Hanford Site and the problems associated with these methods. Means for measuring the gases emitted from the waste are described along with laboratory experiments designed to gain more information regarding rates of generation, species of gases emitted and modes of gas storage and release. Finally, the process for closing the USQ is outlined as are the information requirements to understand and resolve the flammable gas issue.

  14. Flammable Gas Safety Self-Study 52827

    Energy Technology Data Exchange (ETDEWEB)

    Glass, George [Los Alamos National Laboratory

    2016-03-17

    This course, Flammable Gas Safety Self-Study (COURSE 52827), presents an overview of the hazards and controls associated with commonly used, compressed flammable gases at Los Alamos National Laboratory (LANL).

  15. Mapping Emplaced Articulated Concrete Mattress Using Geoelectrical and Electromagnetic Techniques

    National Research Council Canada - National Science Library

    Sjostrom, Keith

    1998-01-01

    Articulated concrete mattresses (ACM) are structures placed parallel to the river current for the purpose of stabilizing the concave banks in river bends, reduce the effects of erosion, and maintain the river channel...

  16. TECHNICAL JUSTIFICATION FOR CHOOSING PROPANE AS A CALIBRATION AGENT FOR TOTAL FLAMMABLE VOLATILE ORGANIC COMPOUND (VOC) DETERMINATIONS

    International Nuclear Information System (INIS)

    DOUGLAS, J.G.

    2006-01-01

    This document presents the technical justification for choosing and using propane as a calibration standard for estimating total flammable volatile organic compounds (VOCs) in an air matrix. A propane-in-nitrogen standard was selected based on a number of criteria: (1) has an analytical response similar to the VOCs of interest, (2) can be made with known accuracy and traceability, (3) is available with good purity, (4) has a matrix similar to the sample matrix, (5) is stable during storage and use, (6) is relatively non-hazardous, and (7) is a recognized standard for similar analytical applications. The Waste Retrieval Project (WRP) desires a fast, reliable, and inexpensive method for screening the flammable VOC content in the vapor-phase headspace of waste containers. Table 1 lists the flammable VOCs of interest to the WRP. The current method used to determine the VOC content of a container is to sample the container's headspace and submit the sample for gas chromatography--mass spectrometry (GC-MS) analysis. The driver for the VOC measurement requirement is safety: potentially flammable atmospheres in the waste containers must be allowed to diffuse prior to processing the container. The proposed flammable VOC screening method is to inject an aliquot of the headspace sample into an argon-doped pulsed-discharge helium ionization detector (Ar-PDHID) contained within a gas chromatograph. No actual chromatography is performed; the sample is transferred directly from a sample loop to the detector through a short, inert transfer line. The peak area resulting from the injected sample is proportional to the flammable VOC content of the sample. However, because the Ar-PDHID has different response factors for different flammable VOCs, a fundamental assumption must be made that the agent used to calibrate the detector is representative of the flammable VOCs of interest that may be in the headspace samples. At worst, we desire that calibration with the selected calibrating

  17. The effect of human-mattress interface's temperature on perceived thermal comfort.

    Science.gov (United States)

    Califano, R; Naddeo, A; Vink, P

    2017-01-01

    In recent years, methods that allow for an objective evaluation of perceived comfort, in terms of postural, physiological, cognitive and environmental comfort, have received a great deal of attention from researchers. This paper focuses on one of the factors that influences physiological comfort perception: the temperature difference between users and the objects with which they interact. The first aim is to create a measuring system that does not affect the perceived comfort during the temperatures' acquisition. The main aim is to evaluate how the temperature at the human-mattress interface can affect the level of perceived comfort. A foam mattress has been used for testing in order to take into account the entire back part of the human body. The temperature at the interface was registered by fourteen 100 Ohm Platinum RTDs (Resistance Temperature Detectors) placed on the mattress under the trunk, the shoulders, the buttocks, the legs, the thighs, the arms and the forearms of the test subject. 29 subjects participated in a comfort test in a humidity controlled environment. The test protocol involved: dress-code, anthropometric-based positioning on mattress, environment temperature measuring and an acclimatization time before the test. At the end of each test, each of the test subject's thermal sensations and the level of comfort perception were evaluated using the ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) scale. The data analyses concerned, in the first instance, correlations between the temperature at the interface and comfort levels of the different parts of the body. Then the same analyses were performed independently of the body parts being considered. The results demonstrated that there was no strong correlation among the studied variables and that the total increase of temperature at interface is associated with a reduction in comfort. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Seasonal and local differences in leaf litter flammability of six Mediterranean tree species.

    Science.gov (United States)

    Kauf, Zorica; Fangmeier, Andreas; Rosavec, Roman; Španjol, Željko

    2015-03-01

    One of the suggested management options for reducing fire danger is the selection of less flammable plant species. Nevertheless, vegetation flammability is both complex and dynamic, making identification of such species challenging. While large efforts have been made to connect plant traits to fire behavior, seasonal changes and within species variability of traits are often neglected. Currently, even the most sophisticated fire danger systems presume that intrinsic characteristics of leaf litter stay unchanged, and plant species flammability lists are often transferred from one area to another. In order to assess if these practices can be improved, we performed a study examining the relationship between morphological characteristics and flammability parameters of leaf litter, thereby taking into account seasonal and local variability. Litter from six Mediterranean tree species was sampled throughout the fire season from three different locations along a climate gradient. Samples were subjected to flammability testing involving an epiradiator operated at 400 °C surface temperature with 3 g sample weight. Specific leaf area, fuel moisture content, average area, and average mass of a single particle had significant influences on flammability parameters. Effects of sampling time and location were significant as well. Due to the standardized testing conditions, these effects could be attributed to changes in intrinsic characteristics of the material. As the aforementioned effects were inconsistent and species specific, these results may potentially limit the generalization of species flammability rankings. Further research is necessary in order to evaluate the importance of our findings for fire danger modeling.

  19. Interstage Flammability Analysis Approach

    Science.gov (United States)

    Little, Jeffrey K.; Eppard, William M.

    2011-01-01

    The Interstage of the Ares I launch platform houses several key components which are on standby during First Stage operation: the Reaction Control System (ReCS), the Upper Stage (US) Thrust Vector Control (TVC) and the J-2X with the Main Propulsion System (MPS) propellant feed system. Therefore potentially dangerous leaks of propellants could develop. The Interstage leaks analysis addresses the concerns of localized mixing of hydrogen and oxygen gases to produce deflagration zones in the Interstage of the Ares I launch vehicle during First Stage operation. This report details the approach taken to accomplish the analysis. Specified leakage profiles and actual flammability results are not presented due to proprietary and security restrictions. The interior volume formed by the Interstage walls, bounding interfaces with the Upper and First Stages, and surrounding the J2-X engine was modeled using Loci-CHEM to assess the potential for flammable gas mixtures to develop during First Stage operations. The transient analysis included a derived flammability indicator based on mixture ratios to maintain achievable simulation times. Validation of results was based on a comparison to Interstage pressure profiles outlined in prior NASA studies. The approach proved useful in the bounding of flammability risk in supporting program hazard reviews.

  20. STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HU TA

    2009-10-26

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The hydrogen generation rate was calculated for 177 tanks using the rate equation model. Flammability calculations based on hydrogen, ammonia, and methane were performed for 177 tanks for various scenarios.

  1. 16 CFR 1500.45 - Method for determining extremely flammable and flammable contents of self-pressurized containers.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Method for determining extremely flammable and flammable contents of self-pressurized containers. 1500.45 Section 1500.45 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS HAZARDOUS SUBSTANCES AND...

  2. Flammability limits: A review with emphasis on ethanol for aeronautical applications and description of the experimental procedure

    International Nuclear Information System (INIS)

    Coronado, Christian J.R.; Carvalho, João A.; Andrade, José C.; Cortez, Ely V.; Carvalho, Felipe S.; Santos, José C.; Mendiburu, Andrés Z.

    2012-01-01

    Highlights: ► Develops a comprehensive literature review on ethanol flammability limits. ► Difference in standard procedures lead to different experimental values of the flammability limits. ► Methodology for experiments to find the FL's of ethanol for aeronautical applications. - Abstract: The lower and upper flammability limits of a fuel are key tools for predicting fire, assessing the possibility of explosion, and designing protection systems. Knowledge about the risks involved with the explosion of both gaseous and vaporized liquid fuel mixtures with air is very important to guarantee safety in industrial, domestic, and aeronautical applications. Currently, most countries use various standard experimental tests, which lead to different experimental values for these limits. A comprehensive literature review of the flammability limits of combustible mixtures is developed here in order to organize the theoretical and practical knowledge of the subject. The main focus of this paper is the review of the flammability data of ethanol–air mixtures available in the literature. In addition, the description of methodology for experiments to find the upper and lower limits of flammability of ethanol for aeronautical applications is discussed. A heated spherical 20 L vessel was used. The mixtures were ignited with electrode rods placed in the center of the vessel, and the spark gap was 6.4 mm. LFL and the UFL were determined for ethanol (hydrated ethanol 96% °INPM) as functions of temperature for atmospheric pressure to compare results with data published in the scientific literature.

  3. A study of the behaviour of and the forces in a bed protecting mattress : The falling apron

    NARCIS (Netherlands)

    Vrijling, J.K.; Ravenstijn, P.

    2001-01-01

    In many cases the bottom around a structure that is exposed to current has to be protected by a mattress. The purpose of the mattress is to protect the soil besides the structure from erosion and scour, thus preserving the strength of the foundation of the structure. Examples are the bottom

  4. 75 FR 49379 - Correction to Internal Citation of “Extremely Flammable Solid” and “Flammable Solid”

    Science.gov (United States)

    2010-08-13

    ... CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Part 1500 Correction to Internal Citation of ``Extremely... to correct internal citations to the definitions of ``extremely flammable solid'' and ``flammable... citation for part 1500 continues to read as follows: Authority: 15 U.S.C. 1261-1277. 0 2. In Sec. 1500.83...

  5. FLAMMABILITY OF HERBICIDE-TREATED GUAVA FOLIAGE

    Science.gov (United States)

    Guava leaves treated with herbicide were found to be less flammable than untreated green leaves or dead leaves . Differences in flammability were...determined by small-scale laboratory fires, differential thermal analysis, and thermogravimetric analysis. The herbicide-treated leaves had a higher ash

  6. 16 CFR Figure 8 to Part 1633 - Jig for Setting Mattresses and Foundation Sides in Same Plane

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Jig for Setting Mattresses and Foundation Sides in Same Plane 8 Figure 8 to Part 1633 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 8 Figure 8 to Part 1633—Jig for Setting Mattresses and Foundation Sides in Same Plane ER15MR06.007 ...

  7. 46 CFR 154.1350 - Flammable gas detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Flammable gas detection system. 154.1350 Section 154... Equipment Instrumentation § 154.1350 Flammable gas detection system. (a) The vessel must have a fixed flammable gas detection system that has sampling points in: (1) Each cargo pump room; (2) Each cargo...

  8. A study on flammability limits of fuel mixtures.

    Science.gov (United States)

    Kondo, Shigeo; Takizawa, Kenji; Takahashi, Akifumi; Tokuhashi, Kazuaki; Sekiya, Akira

    2008-07-15

    Flammability limit measurements were made for various binary and ternary mixtures prepared from nine different compounds. The compounds treated are methane, propane, ethylene, propylene, methyl ether, methyl formate, 1,1-difluoroethane, ammonia, and carbon monoxide. The observed values of lower flammability limits of mixtures were found to be in good agreement to the calculated values by Le Chatelier's formula. As for the upper limits, however, some are close to the calculated values but some are not. It has been found that the deviations of the observed values of upper flammability limits from the calculated ones are mostly to lower concentrations. Modification of Le Chatelier's formula was made to better fit to the observed values of upper flammability limits. This procedure reduced the average difference between the observed and calculated values of upper flammability limits to one-third of the initial value.

  9. Tank 241-C-103 headspace flammability

    International Nuclear Information System (INIS)

    Huckaby, J.L.

    1994-01-01

    Information regarding flammable vapors, gases, and aerosols is presented for the purpose of resolving the tank 241-C-103 headspace flammability issue. Analyses of recent vapor and liquid samples, as well as visual inspections of the tank headspace, are discussed in the context of tank dynamics. This document is restricted to issues regarding the flammability of gases, vapors, and an aerosol that may exist in the headspace of tank 241-C-103. While discussing certain information about the organic liquid present in tank 241-C-103, this document addresses neither the potential for, nor consequences of, a pool fire involving this organic liquid; they will be discussed in a separate report

  10. Tank 241-C-103 headspace flammability

    Energy Technology Data Exchange (ETDEWEB)

    Huckaby, J.L.

    1994-01-01

    Information regarding flammable vapors, gases, and aerosols is presented for the purpose of resolving the tank 241-C-103 headspace flammability issue. Analyses of recent vapor and liquid samples, as well as visual inspections of the tank headspace, are discussed in the context of tank dynamics. This document is restricted to issues regarding the flammability of gases, vapors, and an aerosol that may exist in the headspace of tank 241-C-103. While discussing certain information about the organic liquid present in tank 241-C-103, this document addresses neither the potential for, nor consequences of, a pool fire involving this organic liquid; they will be discussed in a separate report.

  11. 16 CFR 1500.133 - Extremely flammable contact adhesives; labeling.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Extremely flammable contact adhesives... REGULATIONS § 1500.133 Extremely flammable contact adhesives; labeling. (a) Extremely flammable contact adhesives, also known as contact bonding cements, when distributed in containers intended or suitable for...

  12. FLAMMABLE GAS TECHNICAL BASIS DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    KRIPPS, L.J.

    2005-02-18

    This document describes the qualitative evaluation of frequency and consequences for double shell tank (DST) and single shell tank (SST) representative flammable gas accidents and associated hazardous conditions without controls. The evaluation indicated that safety-significant SSCs and/or TSRS were required to prevent or mitigate flammable gas accidents. Discussion on the resulting control decisions is included. This technical basis document was developed to support of the Tank Farms Documented Safety Analysis (DSA) and describes the risk binning process for the flammable gas representative accidents and associated represented hazardous conditions. The purpose of the risk binning process is to determine the need for safety-significant structures, systems, and components (SSC) and technical safety requirement (TSR)-level controls for a given representative accident or represented hazardous condition based on an evaluation of the event frequency and consequence.

  13. FLAMMABLE GAS TECHNICAL BASIS DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    KRIPPS, L.J.

    2005-03-03

    This document describes the qualitative evaluation of frequency and consequences for DST and SST representative flammable gas accidents and associated hazardous conditions without controls. The evaluation indicated that safety-significant structures, systems and components (SSCs) and/or technical safety requirements (TSRs) were required to prevent or mitigate flammable gas accidents. Discussion on the resulting control decisions is included. This technical basis document was developed to support WP-13033, Tank Farms Documented Safety Analysis (DSA), and describes the risk binning process for the flammable gas representative accidents and associated represented hazardous conditions. The purpose of the risk binning process is to determine the need for safety-significant structures, systems, and components (SSC) and technical safety requirement (TSR)-level controls for a given representative accident or represented hazardous condition based on an evaluation of the event frequency and consequence.

  14. Multicenter comparison of the efficacy on prevention of pressure ulcer in postoperative patients between two types of pressure-relieving mattresses in China

    Science.gov (United States)

    Jiang, Qixia; Li, Xiaohua; Zhang, Aiqin; Guo, Yanxia; Liu, Yahong; Liu, Haiying; Qu, Xiaolong; Zhu, Yajun; Guo, Xiujun; Liu, Li; Zhang, Liyan; Bo, Suping; Jia, Jing; Chen, Yuejuan; Zhang, Rui; Wang, Jiandong

    2014-01-01

    Objective: Present study is designed to evaluate the effects of preventing pressure ulcer in surgical patients with two types of pressure-relieving mattresses. Methods: 1074 surgical patients from 12 hospitals in China were divided into A group (static air mattress with repositioning every 2 hours, n = 562) and B group (power pressure air mattress with repositioning every 2 hours, n = 512). The patient was subjected to a pressure-relieving mattress and observed from 0-5 days after surgery. Indications include the Braden scores, hospital-acquired pressure ulcers (HAPU) incidence and stage. Results: The Braden scores between two groups in five days after surgery were no significant (P > 0.05). The incidence of HAPU between two groups in same days also was no significant (1.07% vs. 0.98%, P > 0.05). The incidence of Stage I and stage II pressure ulcers in group A and B were 1.07% (6/562) and 0.98% (5/512), respectively (χ2 = 0.148, P = 0.882). Conclusion: The effects of preventing pressure ulcer in surgical patients with two types of pressure-relieving mattresses are similar, but the protocol by static air mattress with repositioning every 2 hours is benefit when no power. PMID:25356144

  15. Genetic component of flammability variation in a Mediterranean shrub.

    Science.gov (United States)

    Moreira, B; Castellanos, M C; Pausas, J G

    2014-03-01

    Recurrent fires impose a strong selection pressure in many ecosystems worldwide. In such ecosystems, plant flammability is of paramount importance because it enhances population persistence, particularly in non-resprouting species. Indeed, there is evidence of phenotypic divergence of flammability under different fire regimes. Our general hypothesis is that flammability-enhancing traits are adaptive; here, we test whether they have a genetic component. To test this hypothesis, we used the postfire obligate seeder Ulex parviflorus from sites historically exposed to different fire recurrence. We associated molecular variation in potentially adaptive loci detected with a genomic scan (using AFLP markers) with individual phenotypic variability in flammability across fire regimes. We found that at least 42% of the phenotypic variation in flammability was explained by the genetic divergence in a subset of AFLP loci. In spite of generalized gene flow, the genetic variability was structured by differences in fire recurrence. Our results provide the first field evidence supporting that traits enhancing plant flammability have a genetic component and thus can be responding to natural selection driven by fire. These results highlight the importance of flammability as an adaptive trait in fire-prone ecosystems. © 2014 John Wiley & Sons Ltd.

  16. Flammability Assessment Methodology Program Phase I: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    C. A. Loehr; S. M. Djordjevic; K. J. Liekhus; M. J. Connolly

    1997-09-01

    The Flammability Assessment Methodology Program (FAMP) was established to investigate the flammability of gas mixtures found in transuranic (TRU) waste containers. The FAMP results provide a basis for increasing the permissible concentrations of flammable volatile organic compounds (VOCs) in TRU waste containers. The FAMP results will be used to modify the ''Safety Analysis Report for the TRUPACT-II Shipping Package'' (TRUPACT-II SARP) upon acceptance of the methodology by the Nuclear Regulatory Commission. Implementation of the methodology would substantially increase the number of drums that can be shipped to the Waste Isolation Pilot Plant (WIPP) without repackaging or treatment. Central to the program was experimental testing and modeling to predict the gas mixture lower explosive limit (MLEL) of gases observed in TRU waste containers. The experimental data supported selection of an MLEL model that was used in constructing screening limits for flammable VOC and flammable gas concentrations. The MLEL values predicted by the model for individual drums will be utilized to assess flammability for drums that do not meet the screening criteria. Finally, the predicted MLEL values will be used to derive acceptable gas generation rates, decay heat limits, and aspiration time requirements for drums that do not pass the screening limits. The results of the program demonstrate that an increased number of waste containers can be shipped to WIPP within the flammability safety envelope established in the TRUPACT-II SARP.

  17. Assessment of gas flammability in transuranic waste container

    International Nuclear Information System (INIS)

    Connolly, M.J.; Loehr, C.A.; Djordjevic, S.M.; Spangler, L.R.

    1995-01-01

    The Safety Analysis Report for the TRUPACT-II Shipping Package [Transuranic Package Transporter-II (TRUPACT-II) SARP] set limits for gas generation rates, wattage limits, and flammable volatile organic compound (VOC) concentrations in transuranic (TRU) waste containers that would be shipped to the Waste Isolation Pilot Plant (WIPP). Based on existing headspace gas data for drums stored at the Idaho National Engineering Laboratory (INEL) and the Rocky Flats Environmental Technology Site (RFETS), over 30 percent of the contact-handled TRU waste drums contain flammable VOC concentrations greater than the limit. Additional requirements may be imposed for emplacement of waste in the WIPP facility. The conditional no-migration determination (NMD) for the test phase of the facility required that flame tests be performed if significant levels of flammable VOCs were present in TRU waste containers. This paper describes an approach for investigating the potential flammability of TRU waste drums, which would increase the allowable concentrations of flammable VOCS. A flammability assessment methodology is presented that will allow more drums to be shipped to WIPP without treatment or repackaging and reduce the need for flame testing on drums. The approach includes experimental work to determine mixture lower explosive limits (MLEL) for the types of gas mixtures observed in TRU waste, a model for predicting the MLEL for mixtures of VOCS, hydrogen, and methane, and revised screening limits for total flammable VOCs concentrations and concentrations of hydrogen and methane using existing drum headspace gas data and the model predictions

  18. An Enhanced Sensing Application Based on a Flexible Projected Capacitive-Sensing Mattress

    Directory of Open Access Journals (Sweden)

    Wen-Ying Chang

    2014-04-01

    Full Text Available This paper presents a cost-effective sensor system for mattresses that can classify the sleeping posture of an individual and prevent pressure ulcers. This system applies projected capacitive sensing to the field of health care. The charge time (CT method was used to sensitively and accurately measure the capacitance of the projected electrodes. The required characteristics of the projected capacitor were identified to develop large-area applications for sensory mattresses. The area of the electrodes, the use of shielding, and the increased length of the transmission line were calibrated to more accurately measure the capacitance of the electrodes in large-size applications. To offer the users comfort in the prone position, a flexible substrate was selected and covered with 16 × 20 electrodes. Compared with the static charge sensitive bed (SCSB, our proposed system-flexible projected capacitive-sensing mattress (FPCSM comes with more electrodes to increase the resolution of posture identification. As for the body pressure system (BPS, the FPCSM has advantages such as lower cost, higher aging-resistance capability, and the ability to sense the capacitance of the covered regions without physical contact. The proposed guard ring design effectively absorbs the noise and interrupts leakage paths. The projected capacitive electrode is suitable for proximity-sensing applications and succeeds at quickly recognizing the sleeping pattern of the user.

  19. An Approach to the Flammability Testing of Aerospace Materials

    Science.gov (United States)

    Hirsch, David B.

    2012-01-01

    Presentation reviews: (1) Current approach to evaluation of spacecraft materials flammability (2) The need for and the approach to alternative routes (3) Examples of applications of the approach recommended a) Crew Module splash down b) Crew Module depressurization c) Applicability of NASA's flammability test data to other sample configurations d) Applicability of NASA's ground flammability test data to spacecraft environments

  20. Overview of the Flammability of Gases Generated in Hanford Waste Tanks

    International Nuclear Information System (INIS)

    Mahoney, Lenna A.; Huckaby, James L.; Bryan, Samuel A.; Johnson, Gerald D.

    2000-01-01

    This report presents an overview of what is known about the flammability of the gases generated and retained in Hanford waste tanks in terms of the gas composition, flammability and detonability limits of the gas constituents, and availability of ignition sources. The intrinsic flammability (or non-flammability) of waste gas mixtures is one major determinant of whether a flammable region develops in the tank headspace; other factors are the rate, surface area, and volume of the release and the tank ventilation rate, which are not covered in this report

  1. 10 CFR 36.69 - Irradiation of explosive or flammable materials.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Irradiation of explosive or flammable materials. 36.69... IRRADIATORS Operation of Irradiators § 36.69 Irradiation of explosive or flammable materials. (a) Irradiation... cause radiation overexposures of personnel. (b) Irradiation of more than small quantities of flammable...

  2. On the temperature dependence of flammability limits of gases.

    Science.gov (United States)

    Kondo, Shigeo; Takizawa, Kenji; Takahashi, Akifumi; Tokuhashi, Kazuaki

    2011-03-15

    Flammability limits of several combustible gases were measured at temperatures from 5 to 100 °C in a 12-l spherical flask basically following ASHRAE method. The measurements were done for methane, propane, isobutane, ethylene, propylene, dimethyl ether, methyl formate, 1,1-difluoroethane, ammonia, and carbon monoxide. As the temperature rises, the lower flammability limits are gradually shifted down and the upper limits are shifted up. Both the limits shift almost linearly to temperature within the range examined. The linear temperature dependence of the lower flammability limits is explained well using a limiting flame temperature concept at the lower concentration limit (LFL)--'White's rule'. The geometric mean of the flammability limits has been found to be relatively constant for many compounds over the temperature range studied (5-100 °C). Based on this fact, the temperature dependence of the upper flammability limit (UFL) can be predicted reasonably using the temperature coefficient calculated for the LFL. However, some compounds such as ethylene and dimethyl ether, in particular, have a more complex temperature dependence. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. 14 CFR 26.37 - Pending type certification projects: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pending type certification projects: Fuel tank flammability. 26.37 Section 26.37 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... AIRPLANES Fuel Tank Flammability § 26.37 Pending type certification projects: Fuel tank flammability. (a...

  4. Using a rainforest-flame forest mosaic to test the hypothesis that leaf and litter fuel flammability is under natural selection.

    Science.gov (United States)

    Clarke, Peter J; Prior, Lynda D; French, Ben J; Vincent, Ben; Knox, Kirsten J E; Bowman, David M J S

    2014-12-01

    We used a mosaic of infrequently burnt temperate rainforest and adjacent, frequently burnt eucalypt forests in temperate eastern Australia to test whether: (1) there were differences in flammability of fresh and dried foliage amongst congeners from contrasting habitats, (2) habitat flammability was related to regeneration strategy, (3) litter fuels were more flammable in frequently burnt forests, (4) the severity of a recent fire influenced the flammability of litter (as this would suggest fire feedbacks), and (5) microclimate contributed to differences in fire hazard amongst habitats. Leaf-level comparisons were made among 11 congeneric pairs from rainforest and eucalypt forests. Leaf-level ignitability, combustibility and sustainability were not consistently higher for taxa from frequently burnt eucalypt forests, nor were they higher for species with fire-driven recruitment. The bulk density of litter-bed fuels strongly influenced flammability, but eucalypt forest litter was not less dense than rainforest litter. Ignitability, combustibility and flame sustainability of community surface fuels (litter) were compared using fuel arrays with standardized fuel mass and moisture content. Forests previously burned at high fire severity did not have consistently higher litter flammability than those burned at lower severity or long unburned. Thus, contrary to the Mutch hypothesis, there was no evidence of higher flammability of litter fuels or leaves from frequently burnt eucalypt forests compared with infrequently burnt rainforests. We suggest the manifest pyrogenicity of eucalypt forests is not due to natural selection for more flammable foliage, but better explained by differences in crown openness and associated microclimatic differences.

  5. A highly conductive, non-flammable polymer–nanoparticle hybrid electrolyte

    KAUST Repository

    Agrawal, Akanksha; Choudhury, Snehashis; Archer, Lynden A.

    2015-01-01

    liquid media as the electrolyte solvent. Remarkably, we also find that even in highly flammable liquid media, the bidisperse nanoparticle hybrid electrolytes can be formulated to exhibit low or no flammability without compromising their favorable room

  6. Self-Flammability of Gases Generated by Hanford Tank Waste and the Potential of Nitrogen Inerting to Eliminate Flammability Safety Concerns

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-10-12

    Through radiolytic and thermolytic reactions, Hanford tank wastes generate and retain a variety of gases, including hydrogen, nitrous oxide, methane (and other hydrocarbons), ammonia, and nitrogen. This gas generation can be expected to continue during processing in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The generation rates in the WTP will change from those for the in-situ tank waste because of different process temperatures, different dose rates produced by in-process changes in the proportions of solid and liquid, and dilution of the waste liquid. The flammability of the generated gas that is continuously released, and of any retained gas that might be released into a vessel headspace in quantity due to a spontaneous release, depends on the concentrations not only of the fuel gases—primarily hydrogen (H2), methane, other hydrocarbons, and ammonia—but of the oxidizer nitrous oxide (N2O). As a result of high concentrations of N2O, some gas mixtures are “self-flammable” (i.e., ignition can occur when no air is present because N2O provides the only oxidizer needed). Self-flammability could potentially reduce the effectiveness of using a nitrogen (N2) purge in the headspace as a flammability control, if its effects are not accounted for. A given amount of inertant gas (N2) can accommodate only a certain amount of a generated self-flammable gas before the mixture with inertant gas becomes flammable.

  7. 14 CFR Appendix M to Part 25 - Fuel Tank System Flammability Reduction Means

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel Tank System Flammability Reduction... 25—Fuel Tank System Flammability Reduction Means M25.1Fuel tank flammability exposure requirements. (a) The Fleet Average Flammability Exposure of each fuel tank, as determined in accordance with...

  8. Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair.

    Science.gov (United States)

    Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q

    2014-03-01

    We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.

  9. Method of burning flammable radioactive wastes

    International Nuclear Information System (INIS)

    Yahata, Taneaki.

    1980-01-01

    Purpose: To completely oxidize flammable radioactive wastes such as organic compounds, ion exchange materials or oils. Method: Contaminated flammable radioactive wastes are heated and pyrolytically decomposed in the range 400 0 to 500 0 C in the presence of oxygen under lower pressure than atmospheric pressure. Volatile organic substance, hydrogen and soot subsequently produced are passed over oxidation catalyst. The catalysts such as copper oxide, iron oxide, cobalt oxide, nickel oxide, chromium oxide are heated in the range 600 0 to 700 0 C to produce stable oxides. (J.P.N.)

  10. Overview of the Flammability of Gases Generated in Hanford Waste Tanks

    International Nuclear Information System (INIS)

    Mahoney, L.A.; Huckaby, J.L.; Bryan, S.A.; Johnson, G.D.

    2000-01-01

    This report presents an overview of what is known about the flammability of the gases generated and retained in Hanford waste tanks in terms of the gas composition, the flammability and detonability limits of the gas constituents, and the availability of ignition sources. The intrinsic flammability (or nonflammability) of waste gas mixtures is one major determinant of whether a flammable region develops in the tank headspace; other factors are the rate, surface area, volume of the release, and the tank ventilation rate, which are not covered in this report

  11. A Simple Technique to Estimate the Flammability Index of Moroccan Forest Fuels

    Directory of Open Access Journals (Sweden)

    M'Hamed Hachmi

    2011-01-01

    Full Text Available A formula to estimate forest fuel flammability index (FI is proposed, integrating three species flammability parameters: time to ignition, time of combustion, and flame height. Thirty-one (31 Moroccan tree and shrub species were tested within a wide range of fuel moisture contents. Six species flammability classes were identified. An ANOVA of the FI-values was performed and analyzed using four different sample sizes of 12, 24, 36, and 50 flammability tests. Fuel humidity content is inversely correlated to the FI-value, and the linear model appears to be the most adequate equation that may predict the hypothetical threshold-point of humidity of extinction. Most of the Moroccan forest fuels studied are classified as moderately flammable to flammable species based on their average humidity content, calculated for the summer period from July to September.

  12. FLAMMABLE GAS DIFFUSION THROUGH SINGLE SHELL TANK (SST) DOMES

    Energy Technology Data Exchange (ETDEWEB)

    MEACHAM, J.E.

    2003-11-10

    This report quantified potential hydrogen diffusion through Hanford Site Single-Shell tank (SST) domes if the SSTs were hypothetically sealed airtight. Results showed that diffusion would keep headspace flammable gas concentrations below the lower flammability limit in the 241-AX and 241-SX SST. The purpose of this document is to quantify the amount of hydrogen that could diffuse through the domes of the SSTs if they were hypothetically sealed airtight. Diffusion is assumed to be the only mechanism available to reduce flammable gas concentrations. The scope of this report is limited to the 149 SSTs.

  13. Geographical variation and the determinants of domestic endotoxin levels in mattress dust in Europe

    NARCIS (Netherlands)

    Chen, C.M.; Thiering, E.; Doekes, G.; Zock, J.P.; Bakolis, I.; Norbäck, D.; Sunyer, J.; Villani, S.; Verlato, G.; Täubel, M.; Jarvis, D.

    2012-01-01

    Endotoxin exposures have manifold effects on human health. The geographical variation and determinants of domestic endotoxin levels in Europe have not yet been extensively described. To investigate the geographical variation and determinants of domestic endotoxin concentrations in mattress dust in

  14. Tank 24-C-103 headspace flammability

    International Nuclear Information System (INIS)

    Huckaby, J.L.

    1994-05-01

    Information regarding flammable vapors, gases, and aerosols is presented and interpreted to help resolve the tank 241-C-103 headspace flammability issue. Analyses of recent vapor and liquid samples, as well as visual inspections of the tank headspace, are discussed in the context of tank dynamics. Concern that the headspace of tank 241-C-103 may contain a flammable mixture of organic vapors and an aerosol of combustible organic liquid droplets arises from the presence of a layer of organic liquid in the tank. This organic liquid is believed to have originated in the plutonium-uranium extraction (PUREX) process, having been stored initially in tank 241-C-102 and apparently transferred to tank 241-C-103 in 1975 (Carothers 1988). Analyses of samples of the organic liquid collected in 1991 and 1993 indicate that the primary constituents are tributyl phosphate (TBP) and several semivolatile hydrocarbons (Prentice 1991, Pool and Bean 1994). This is consistent with the premise that the organic waste came from the PUREX process, because the PUREX process used a solution of TBP in a diluent composed of the n-C 11 H 24 to n-C 15 H 32 normal paraffinic hydrocarbons (NPH)

  15. 49 CFR 174.304 - Class 3 (flammable liquid) materials in tank cars.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Class 3 (flammable liquid) materials in tank cars... (flammable liquid) materials in tank cars. A tank car containing a Class 3 (flammable liquid) material, other... the liquid from the tank car to permanent storage tanks of sufficient capacity to receive the entire...

  16. Finite element modeling for predicting the contact pressure between a foam mattress and the human body in a supine position.

    Science.gov (United States)

    Lee, Wookjin; Won, Byeong Hee; Cho, Seong Wook

    2017-01-01

    In this paper, we generated finite element (FE) models to predict the contact pressure between a foam mattress and the human body in a supine position. Twenty-year-old males were used for three-dimensional scanning to produce the FE human models, which was composed of skin and muscle tissue. A linear elastic isotropic material model was used for the skin, and the Mooney-Rivlin model was used for the muscle tissue because it can effectively represent the nonlinear behavior of muscle. The contact pressure between the human model and the mattress was predicted by numerical simulation. The human models were validated by comparing the body pressure distribution obtained from the same human subject when he was lying on two different mattress types. The experimental results showed that the slope of the lower part of the mattress caused a decrease in the contact pressure at the heels, and the effect of bone structure was most pronounced in the scapula. After inserting a simple structure to function as the scapula, the contact pressure predicted by the FE human models was consistent with the experimental body pressure distribution for all body parts. These results suggest that the models proposed in this paper will be useful to researchers and designers of products related to the prevention of pressure ulcers.

  17. Flammable gas issues in double-contained receiver tanks. Revision 2

    International Nuclear Information System (INIS)

    Peurrung, L.M.; Mahoney, L.A.; Stewart, C.W.; Gauglitz, P.A.; Pederson, L.R.; Bryan, S.A.; Shepard, C.L.

    1998-08-01

    Four double-contained receiver tanks (DCRTs) at Hanford will be used to store salt-well pumped liquids from tanks on the Flammable Gas Watch List. This document was created to serve as a reference document describing the current knowledge of flammable gas issues in DCRTs. The document identifies, describes, evaluates, and attempts to quantify potential gas carryover and release mechanisms. It estimates several key parameters needed for these calculations, such as initial aqueous concentrations and ventilation rate, and evaluates the uncertainty in those estimates. It justifies the use of the Schumpe model for estimating vapor-liquid equilibrium constants. It identifies several potential waste compatibility issues (such as mixing and pH or temperature changes) that could lead to gas release and provides a basis for calculating their effects. It evaluates the potential for gas retention in precipitated solids within a DCRT and whether retention could lead to a buoyant displacement instability (rollover) event. It discusses rates of radiolytic, thermal, and corrosive hydrogen generation within the DCRT. It also describes in detail the accepted method of calculating the lower flammability limit (LFL) for mixtures of flammable gases. The report incorporates these analyses into two models for calculating headspace flammability, one based on instantaneous equilibrium between dissolved gases and the headspace and one incorporating limited release rates based on mass-transfer considerations. Finally, it demonstrates the use of both models to estimate headspace flammable gas concentrations and minimum ventilation rates required to maintain concentrations below 25% of the LFL

  18. A risk-based approach to flammable gas detector spacing.

    Science.gov (United States)

    Defriend, Stephen; Dejmek, Mark; Porter, Leisa; Deshotels, Bob; Natvig, Bernt

    2008-11-15

    Flammable gas detectors allow an operating company to address leaks before they become serious, by automatically alarming and by initiating isolation and safe venting. Without effective gas detection, there is very limited defense against a flammable gas leak developing into a fire or explosion that could cause loss of life or escalate to cascading failures of nearby vessels, piping, and equipment. While it is commonly recognized that some gas detectors are needed in a process plant containing flammable gas or volatile liquids, there is usually a question of how many are needed. The areas that need protection can be determined by dispersion modeling from potential leak sites. Within the areas that must be protected, the spacing of detectors (or alternatively, number of detectors) should be based on risk. Detector design can be characterized by spacing criteria, which is convenient for design - or alternatively by number of detectors, which is convenient for cost reporting. The factors that influence the risk are site-specific, including process conditions, chemical composition, number of potential leak sites, piping design standards, arrangement of plant equipment and structures, design of isolation and depressurization systems, and frequency of detector testing. Site-specific factors such as those just mentioned affect the size of flammable gas cloud that must be detected (within a specified probability) by the gas detection system. A probability of detection must be specified that gives a design with a tolerable risk of fires and explosions. To determine the optimum spacing of detectors, it is important to consider the probability that a detector will fail at some time and be inoperative until replaced or repaired. A cost-effective approach is based on the combined risk from a representative selection of leakage scenarios, rather than a worst-case evaluation. This means that probability and severity of leak consequences must be evaluated together. In marine and

  19. Flammability tests for regulation of building and construction materials

    Science.gov (United States)

    K. Sumathipala

    2006-01-01

    The regulation of building materials and products for flammability is critical to ensure the safety of occupants in buildings and other structures. The involvement of exposed building materials and products in fires resulting in the loss of human life often spurs an increase in regulation and new test methods to address the problem. Flammability tests range from those...

  20. Strategy for resolution of the flammable gas safety issue

    International Nuclear Information System (INIS)

    Johnson, G.D.

    1997-01-01

    This document provides a strategy for resolution of the Flammable Gas Safety Issue. It defines the key elements required for the following: Closing the Flammable Gas Unreviewed Safety Question (USQ); Providing the administrative basis for resolving the safety issue; Defining the data needed to support these activities; and Providing the technical and administrative path for removing tanks from the Watch List

  1. Strategy for resolution of the flammable gas safety issue

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.D.

    1997-05-23

    This document provides a strategy for resolution of the Flammable Gas Safety Issue. It defines the key elements required for the following: Closing the Flammable Gas Unreviewed Safety Question (USQ); Providing the administrative basis for resolving the safety issue; Defining the data needed to support these activities; and Providing the technical and administrative path for removing tanks from the Watch List.

  2. Flammability on textile of flight crew professional clothing

    Science.gov (United States)

    Silva-Santos, M. C.; Oliveira, M. S.; Giacomin, A. M.; Laktim, M. C.; Baruque-Ramos, J.

    2017-10-01

    The issue about flammability of textile materials employed in passenger cabins of commercial aircrafts is an important part of safety routines planning. Once an in-flight emergency initiated with fire or smoke aboard, time becomes critical and the entire crew must be involved in the solution. It is part of the crew functions, notably the attendants, the in-flight firefighting. This study compares the values of textile material of flight attendant working cloths and galley curtain fabric with regard to flammability and Limiting Oxygen Index (LOI). Values to the professional clothing material indicate that they are flammable and the curtains, self-extinguishing. Thus, despite of the occurrences of fire outbreaks in aircrafts are unexceptional, the use of other materials and technologies for uniforms, such as alternative textile fibers and flame retardant finishes should be considered as well as the establishment of performance limits regarding flame and fire exposing.

  3. Flammability of kerosene in civil and military aviation

    Energy Technology Data Exchange (ETDEWEB)

    Sochet, I.; Gillard, P. [Universite d' Orleans, Lab. Energetique Explosions Structures, Bourges cedex, 18 (France)

    2002-09-01

    The investigation of the ignition conditions of kerosene vapors in the air contained in an aircraft fuel tank contributes to the definition of onboard safety requirements. Civil and military kerosene are characterized by specification. The specification of civil aviation kerosene is based upon usage requirements and property limits, while military kerosene is primarily controlled by specific chemical composition. Characterization of the flammability properties is a first step for the establishment of aircraft safety conditions. Flash point, vapor pressure, gas chromatography analysis, and flammability properties of the kerosene used by the French Military aviation (F-34 and F-35 kerosene) are compared with the flammability properties of civil kerosene. The empirical law established by the Federal Aviation Administration (FAA) in 1998, expressing the ignition energy in terms of fuel, temperature, flash point and altitude is modified and expressed in terms of fuel temperature, flash point and pressure. (Author)

  4. Integration of the Uncertainties of Anion and TOC Measurements into the Flammability Control Strategy for Sludge Batch 8 at the DWPF

    International Nuclear Information System (INIS)

    Edwards, T. B.

    2013-01-01

    The Savannah River National Laboratory (SRNL) has been working with the Savannah River Remediation (SRR) Defense Waste Processing Facility (DWPF) in the development and implementation of a flammability control strategy for DWPF's melter operation during the processing of Sludge Batch 8 (SB8). SRNL's support has been in response to technical task requests that have been made by SRR's Waste Solidification Engineering (WSE) organization. The flammability control strategy relies on measurements that are performed on Slurry Mix Evaporator (SME) samples by the DWPF Laboratory. Measurements of nitrate, oxalate, formate, and total organic carbon (TOC) standards generated by the DWPF Laboratory are presented in this report, and an evaluation of the uncertainties of these measurements is provided. The impact of the uncertainties of these measurements on DWPF's strategy for controlling melter flammability also is evaluated. The strategy includes monitoring each SME batch for its nitrate content and its TOC content relative to the nitrate content and relative to the antifoam additions made during the preparation of the SME batch. A linearized approach for monitoring the relationship between TOC and nitrate is developed, equations are provided that integrate the measurement uncertainties into the flammability control strategy, and sample calculations for these equations are shown to illustrate the impact of the uncertainties on the flammability control strategy

  5. Electrical safety in flammable gas/vapor laden atmospheres

    CERN Document Server

    Korver, WOE

    1992-01-01

    This book provides comprehensive coverage of electrical system installation within areas where flammable gases and liquids are handled and processed. The accurate hazard evaluation of flammability risks associated with chemical and petrochemical locations is critical in determining the point at which the costs of electrical equipment and installation are balanced with explosion safety requirements. The book offers the most current code requirements along with tables and illustrations as analytic tools. Environmental characteristics are covered in Section 1 along with recommended electrical ins

  6. 14 CFR 26.39 - Newly produced airplanes: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Newly produced airplanes: Fuel tank... Tank Flammability § 26.39 Newly produced airplanes: Fuel tank flammability. (a) Applicability: This... Series 767 Series (b) Any fuel tank meeting all of the criteria stated in paragraphs (b)(1), (b)(2) and...

  7. Modelling leaf, plant and stand flammability for ecological and operational decision making

    Science.gov (United States)

    Zylstra, Philip

    2014-05-01

    Numerous factors have been found to affect the flammability of individual leaves and plant parts; however the way in which these factors relate to whole plant flammability, fire behaviour and the overall risk imposed by fire is not straightforward. Similarly, although the structure of plant communities is known to affect the flammability of the stand, a quantified, broadly applicable link has proven difficult to establish and validate. These knowledge gaps have presented major obstacles to the integration into fire behaviour science of research into factors affecting plant flammability, physiology, species succession and structural change, so that the management of ecosystems for fire risk is largely uninformed by these fields. The Forest Flammability Model (Zylstra, 2011) is a process-driven, complex systems model developed specifically to address this disconnect. Flame dimensions and position are calculated as properties emerging from the capacity for convective heat to propagate flame between horizontally and vertically separated leaves, branches, plants and plant strata, and this capacity is determined dynamically from the ignitability, combustibility and sustainability of those objects, their spatial arrangement and a vector-based model of the plume temperature from each burning fuel. All flammability properties as well as the physics of flame dimensions, angle and temperature distributions and the vertical structure of wind within the plant array use published sub-models which can be replaced as further work is developed. This modular structure provides a platform for the immediate application of new work on any aspect of leaf flammability or fire physics. Initial validation of the model examined its qualitative predictions for trends in forest flammability as a function of time since fire. The positive feedback predicted for the subalpine forest examined constituted a 'risky prediction' by running counter to the expectations of the existing approach, however

  8. A summary description of the flammable gas tank safety program

    International Nuclear Information System (INIS)

    Johnson, G.D.; Sherwood, D.J.

    1994-10-01

    Radioactive liquid waste may produce hydrogen as result of the interaction of gamma radiation and water. If the waste contains organic chelating agents, additional hydrogen as well as nitrous oxide and ammonia may be produced by thermal and radiolytic decomposition of these organics. Several high-level radioactive liquid waste storage tanks, located underground at the Hanford Site in Washington State, are on a Flammable Gas Watch List. Some contain waste that produces and retains gases until large quantities of gas are released rapidly to the tank vapor space. Tanks nearly-filled to capacity have relatively little vapor space; therefore if the waste suddenly releases a large amount of hydrogen and nitrous oxide, a flammable gas mixture could result. The most notable example of a Hanford waste tank with a flammable gas problem is tank 241-SY-101. Upon occasion waste stored in this tank has released enough flammable gas to burn if an ignition source had been present inside of the tank. Several, other Hanford waste tanks exhibit similar behavior although to a lesser magnitude. Because this behavior was hot adequately-addressed in safety analysis reports for the Hanford Tank Farms, an unreviewed safety question was declared, and in 1990 the Flammable Gas Tank Safety Program was established to address this problem. The purposes of the program are a follows: (1) Provide safety documents to fill gaps in the safety analysis reports, and (2) Resolve the safety issue by acquiring knowledge about gas retention and release from radioactive liquid waste and developing mitigation technology. This document provides the general logic and work activities required to resolve the unreviewed safety question and the safety issue of flammable gas mixtures in radioactive liquid waste storage tanks

  9. Results of gas monitoring of double-shell flammable gas watch list tanks

    International Nuclear Information System (INIS)

    Wilkins, N.E.

    1995-01-01

    Tanks 103-SY; 101-AW; 103-, 104-, and 105-AN are on the Flammable Gas Watch List. Recently, standard hydrogen monitoring system (SHMS) cabinets have been installed in the vent header of each of these tanks. Grab samples have been taken once per week, and a gas chromatograph was installed on tank 104-AN as a field test. The data that have been collected since gas monitoring began on these tanks are summarized in this document

  10. Controlling the ignition and flammability of magnesium for aerospace applications

    International Nuclear Information System (INIS)

    Czerwinski, Frank

    2014-01-01

    The perceived easy ignition and flammability of magnesium alloys create a detrimental safety feature that overshadows their high strength-to-weight ratio and hinders the aerospace application opportunities. To overcome the existing barriers a progress in understanding and controlling the reactivity of magnesium at high temperatures is required. This report describes fundamentals of magnesium ignition and flammability along with laboratory testing procedures and correlations with full scale fire scenarios, related in particular to the aircraft cabin. The influence of alloying elements on high temperature reactivity of magnesium and global efforts to develop ignition resistant and non-flammable magnesium alloys are reviewed. Although ignition and flammability represent quite different quantities, both are controlled by an oxidation resistance of the alloy and its capability to form a dense and protective surface oxide after exposures to an open flame or other heat source. Since surface oxide, composed of pure MgO, does not offer a sufficient protection, the research strategy is focused on modification of its chemistry and microstructure by micro-alloying the substrate with rare earths and other elements having high affinity to oxygen

  11. Results of Vapor Space Monitoring of Flammable Gas Watch List Tanks

    Energy Technology Data Exchange (ETDEWEB)

    MCCAIN, D.J.

    2000-09-27

    This report documents the measurement of headspace gas concentrations and monitoring results from the Hanford tanks that have continuous flammable gas monitoring. The systems used to monitor the tanks are Standard Hydrogen Monitoring Systems. Further characterization of the tank off-gases was done with Gas Characterization systems and vapor grab samples. The background concentrations of all tanks are below the action level of 6250 ppm. Other information which can be derived from the measurements (such as generation rate, released rate, and ventilation rate) is also discussed.

  12. Results of vapor space monitoring of flammable gas Watch List tanks

    International Nuclear Information System (INIS)

    Wilkins, N.E.

    1997-01-01

    This report documents the measurement of headspace gas concentrations and monitoring results from the Hanford tanks that have continuous flammable gas monitoring. The systems used to monitor the tanks are Standard Hydrogen Monitoring Systems. Further characterization of the tank off-gases was done with Gas Characterization Systems and vapor grab samples. The background concentrations of all tanks are below the action level of 6250 ppm. Other information which can be derived from the measurements (such as generation rate, release rate, and ventilation rate) is also discussed

  13. Emission of phthalates and phthalate alternatives from vinyl flooring and crib mattress covers: the influence of temperature.

    Science.gov (United States)

    Liang, Yirui; Xu, Ying

    2014-12-16

    Emissions of phthalates and phthalate alternatives from vinyl flooring and crib mattress covers were measured in a specially designed chamber. The gas-phase concentrations versus time were measured at four different temperatures, that is, 25, 36, 45, and 55 °C. The key parameter that controls the emissions (y0, gas-phase concentration in equilibrium with the material phase) was determined, and the emissions were found to increase significantly with increasing temperature. Both the material-phase concentration (C0) and the chemical vapor pressure (Vp) were found to have great influence on the value of y0. The measured ratios of C0 to y0 were exponentially proportional to the reciprocal of temperature, in agreement with the van't Hoff equation. A emission model was validated at different temperatures, with excellent agreement between model calculations and chamber observations. In residential homes, an increase in the temperature from 25 to 35 °C can elevate the gas-phase concentration of phthalates by more than a factor of 10, but the total airborne concentration may not increase that much for less volatile compounds. In infant sleep microenvironments, an increase in the temperature of mattress can cause a significant increase in emission of phthalates from the mattress cover and make the concentration in the infant's breathing zone about four times higher than that in the bulk room air, resulting in potentially high exposure.

  14. Position paper on flammability concerns associated with TRU waste destined for WIPP

    International Nuclear Information System (INIS)

    1991-04-01

    The Waste Isolation Pilot Plant (WIPP), in southeastern New Mexico,is an underground repository, designed for the safe geologic disposal of transuranic (TRU) wastes generated from defense-related activities of the US Department of Energy (DOE). The WIPP storage rooms are mined in a bedded salt (halite) formation, and are located 2150 feet below the surface. After the disposal of waste in the storage rooms, closure of the repository is expected to occur by creep (plastic flow) of the salt formation, with the waste being permanently isolated from the surrounding environment. This paper has evaluated the issue of flammability concerns associated with TRU waste to be shipped to WIPP, including a review of possible scenarios that can potentially contribute to the flammability. The paper discusses existing regulations that address potential flammability concerns, presents an analysis of previous flammability-related incidents at DOE sites with respect to the current regulations, and finally, examines the degree of assurance these regulations provide in safeguarding against flammability concerns during transportation and waste handling. 50 refs., 7 figs., 7 tabs

  15. Flammable gas data evaluation. Progress report

    International Nuclear Information System (INIS)

    Whitney, P.D.; Meyer, P.A.; Miller, N.E.

    1996-10-01

    The Hanford Site is home to 177 large, underground nuclear waste storage tanks. Numerous safety and environmental concerns surround these tanks and their contents. One such concern is the propensity for the waste in these tanks to generate, retain, and periodically release flammable gases. This report documents some of the activities of the Flammable Gas Project Data Evaluation Task conducted for Westinghouse Hanford Company during fiscal year 1996. Described in this report are: (1) the results of examining the in-tank temperature measurements for insights into gas release behavior; (2) the preliminary results of examining the tank waste level measurements for insights into gas release behavior; and (3) an explanation for the observed hysteresis in the level/pressure measurements, a phenomenon observed earlier this year when high-frequency tank waste level measurements came on-line

  16. Dermatophagoides pteronyssinus (Trouessart, 1897) in mattress and floor dust in a temperate climate (Acari : Pyroglyphidae)

    NARCIS (Netherlands)

    Bronswijk, van J.E.M.H.

    1973-01-01

    The arthropod fauna of mattress dust, bedroom dust and living-room dust was sampled during a 1-year period in a center for asthmatic children (near Nijmegen, The Netherlands) with the aid of a vacuum cleaner, Berlese funnels and a flotation method. Dermatophagoides pteronyssinus was most abundant;

  17. Remote flammable gas detection/measuring device.

    CSIR Research Space (South Africa)

    Kononov, VA

    1999-11-01

    Full Text Available This research report presents the results of an evaluation of the existing open path remote flammable gas detection/monitoring technology and provides recommendations on possible limited implementation of this technology and future development...

  18. A randomized trial of exothermic mattresses for preterm newborns in polyethylene bags.

    LENUS (Irish Health Repository)

    McCarthy, Lisa K

    2013-07-01

    Hypothermia on admission to the NICU is associated with increased mortality in preterm infants. Many newborns are hypothermic on admission despite using polyethylene bags (PBs). Using exothermic mattresses (EMs) in addition to PBs may reduce hypothermia but increase hyperthermia. We wished to determine whether placing preterm newborns in PBs on EMs in the DR results in more infants with rectal temperature outside the range 36.5 to 37.5°C on NICU admission.

  19. Effect of mattress and pillow encasings on children with asthma and house dust mite allergy

    DEFF Research Database (Denmark)

    Halken, Susanne; Høst, Arne; Niklassen, Ulla

    2003-01-01

    BACKGROUND: House dust mite (HDM) allergy is a frequent cause of allergic asthma in children. Reduction of exposure seems to be the most logical way to treat these patients. OBJECTIVE: Our aim was to investigate whether mattress and pillow encasings resulted in an effective long-term control of H...

  20. Hazard assessments of double-shell flammable gas tanks

    International Nuclear Information System (INIS)

    Fox, G.L.; Stepnewski, D.D.

    1994-01-01

    This report is the fourth in a series of hazard assessments performed on the double-shell flammable gas watch list tanks. This report focuses on hazards associated with the double-shell watch list tanks (101-AW, 103-AN, 104-AN, and 105-AN). While a similar assessment has already been performed for tank 103-SY, it is also included here to incorporate a more representative slurry gas mixture and provide a consistent basis for comparing results for all the flammable gas tanks. This report is intended to provide an in-depth assessment by considering the details of the gas release event and slurry gas mixing as the gas is released from the waste. The consequences of postulated gas ignition are evaluated using a plume burn model and updated ignition frequency predictions. Tank pressurization which results from a gas burn, along with the structural response, is also considered. The report is intended to support the safety basis for work activities in flammable gas tanks by showing margins to safety limits that are available in the design and procedures

  1. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    Science.gov (United States)

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  2. Flammable gas issues in double-contained receiver tanks. Revision 1

    International Nuclear Information System (INIS)

    Peurrung, L.M.; Mahoney, L.A.; Stewart, C.W.; Gauglitz, P.A.; Pederson, L.R.; Bryan, S.A.; Shepard, C.L.

    1998-06-01

    Four double-contained receiver tanks (DCRTs) at Hanford will be used to store salt-well pumped liquids from tanks on the Flammable Gas Watch List. This document was created to serve as a technical basis or reference document for flammable gas issues in DCRTs. The document identifies, describes, evaluates, and attempts to quantify potential gas carryover and release mechanisms. It estimates several key parameters needed for these calculations, such as initial aqueous concentrations and ventilation rate, and evaluates the uncertainty in those estimates. It justifies the use of the Schumpe model for estimating vapor-liquid equilibrium constants. It identifies several potential waste compatibility issues (such as mixing and pH or temperature changes) that could lead to gas release and provides a basis for calculating their effects. It evaluates the potential for gas retention in precipitated solids within a DCRT and whether retention could lead to a buoyant displacement instability (rollover) event. It discusses rates of radiolytic, thermal, and corrosive hydrogen generation within the DCRT. It also describes in detail the accepted method of calculating the lower flammability limit (LFL) for mixtures of flammable gases

  3. Flammable gas issues in double-contained receiver tanks. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, L.M.; Mahoney, L.A.; Stewart, C.W.; Gauglitz, P.A.; Pederson, L.R.; Bryan, S.A.; Shepard, C.L.

    1998-06-01

    Four double-contained receiver tanks (DCRTs) at Hanford will be used to store salt-well pumped liquids from tanks on the Flammable Gas Watch List. This document was created to serve as a technical basis or reference document for flammable gas issues in DCRTs. The document identifies, describes, evaluates, and attempts to quantify potential gas carryover and release mechanisms. It estimates several key parameters needed for these calculations, such as initial aqueous concentrations and ventilation rate, and evaluates the uncertainty in those estimates. It justifies the use of the Schumpe model for estimating vapor-liquid equilibrium constants. It identifies several potential waste compatibility issues (such as mixing and pH or temperature changes) that could lead to gas release and provides a basis for calculating their effects. It evaluates the potential for gas retention in precipitated solids within a DCRT and whether retention could lead to a buoyant displacement instability (rollover) event. It discusses rates of radiolytic, thermal, and corrosive hydrogen generation within the DCRT. It also describes in detail the accepted method of calculating the lower flammability limit (LFL) for mixtures of flammable gases.

  4. Evaluation of Flammable Gas Monitoring and Ventilation System Alternatives for Double-Contained Receiver Tanks

    International Nuclear Information System (INIS)

    GUSTAVSON, R.D.

    1999-01-01

    This study identifies possible flammable gas monitoring and ventilation system alternatives to ensure adequate removal of flammable gases from the Double-Contained Receiver Tank (DCRT) primary tanks during temporary storage of small amounts of waste. The study evaluates and compares these alternatives to support closure of the Flammable Gas Unreviewed Safety Question (USQ TF-96-04330)

  5. Extended Le Chatelier's formula for carbon dioxide dilution effect on flammability limits.

    Science.gov (United States)

    Kondo, Shigeo; Takizawa, Kenji; Takahashi, Akifumi; Tokuhashi, Kazuaki

    2006-11-02

    Carbon dioxide dilution effect on the flammability limits was measured for various flammable gases. The obtained values were analyzed using the extended Le Chatelier's formula developed in a previous study. As a result, it has been found that the flammability limits of methane, propane, propylene, methyl formate, and 1,1-difluoroethane are adequately explained by the extended Le Chatelier's formula using a common set of parameter values. Ethylene, dimethyl ether, and ammonia behave differently from these compounds. The present result is very consistent with what was obtained in the case of nitrogen dilution.

  6. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of type certificates: Fuel tank... Tank Flammability § 26.33 Holders of type certificates: Fuel tank flammability. (a) Applicability. This... part 25 of this chapter. (2) Exception. This paragraph (b) does not apply to— (i) Fuel tanks for which...

  7. Control Decisions for Flammable Gas Hazards in Waste Transfer Systems

    International Nuclear Information System (INIS)

    KRIPPS, L.J.

    2000-01-01

    This report describes the control decisions for flammable gas hazards in waste transfer systems (i.e., waste transfer piping and waste transfer-associated structures) made at control decision meetings on November 30, 1999a and April 19, 2000, and their basis. These control decisions, and the analyses that support them, will be documented in an amendment to the Final Safety Analysis Report (FSAR) (CHG 2000a) and Technical Safety Requirements (TSR) (CHG 2000b) to close the Flammable Gas Unreviewed Safety Question (USQ) (Bacon 1996 and Wagoner 1996). Following the Contractor Tier I review of the FSAR and TSR amendment, it will be submitted to the US. Department of Energy (DOE), Office of River Protection (ORP) for review and approval. The control decision meeting on November 30, 1999 to address flammable gas hazards in waste transfer systems followed the control decision process and the criteria for control decisions described in Section 3.3.1.5 of the FSAR. The control decision meeting agenda, attendance list, and introductory and background presentations are included in Attachments 1 through 4. The control decision discussions on existing and other possible controls for flammable gas hazards in waste transfer systems and the basis for selecting or not selecting specific controls are summarized in this report

  8. Analysis of flammability limits for the liquefaction process of oxygen-bearing coal-bed methane

    International Nuclear Information System (INIS)

    Li, Q.Y.; Wang, L.; Ju, Y.L.

    2011-01-01

    Highlights: → A novel liquefaction and distillation process is designed for oxygen bearing coal-bed methane. → Oxygen contained in coal-bed methane is removed in distillation process. → Flammability limits are analyzed for the whole operation process. → We find explosion hazard may exist in distillation tower. → Effective measures are proposed to ensure the operation safety in distillation tower. - Abstract: A novel liquefaction and distillation process has been proposed and designed for the typical oxygen-bearing coal-bed methane (CBM), in which the impurities of the oxygen and nitrogen components are removed in the distillation column. The flammability limit theory combining with HYSYS simulation results are employed to analyze and calculate the flammability limits and the results indicate that no flammability hazard exists in the stages of compression, liquefaction and throttling. However, flammability hazard exists at the top the distillation column because the methane mole fraction decreases to the value below the upper flammability limit (UFL). The safety measures of initially removing oxygen content from the feed gas combining with the control of the bottom flowrate (flowrate of the liquid product at column bottom) are proposed to ensure the operation safety of the liquefaction process. The results reveal that the operation safety of the whole process can be guaranteed, together with high methane recovery rate and high purity of the liquid product. The applicability of the liquefaction process has also been analyzed in this paper. The simulation results can offer references for the separation of oxygen from CBM, the analysis of flammability limits and the safety measures for the whole process.

  9. An approximate-reasoning-based method for screening flammable gas tanks

    International Nuclear Information System (INIS)

    Eisenhawer, S.W.; Bott, T.F.; Smith, R.E.

    1998-03-01

    High-level waste (HLW) produces flammable gases as a result of radiolysis and thermal decomposition of organics. Under certain conditions, these gases can accumulate within the waste for extended periods and then be released quickly into the dome space of the storage tank. As part of the effort to reduce the safety concerns associated with flammable gas in HLW tanks at Hanford, a flammable gas watch list (FGWL) has been established. Inclusion on the FGWL is based on criteria intended to measure the risk associated with the presence of flammable gas. It is important that all high-risk tanks be identified with high confidence so that they may be controlled. Conversely, to minimize operational complexity, the number of tanks on the watchlist should be reduced as near to the true number of flammable risk tanks as the current state of knowledge will support. This report presents an alternative to existing approaches for FGWL screening based on the theory of approximate reasoning (AR) (Zadeh 1976). The AR-based model emulates the inference process used by an expert when asked to make an evaluation. The FGWL model described here was exercised by performing two evaluations. (1) A complete tank evaluation where the entire algorithm is used. This was done for two tanks, U-106 and AW-104. U-106 is a single shell tank with large sludge and saltcake layers. AW-104 is a double shell tank with over one million gallons of supernate. Both of these tanks had failed the screening performed by Hodgson et al. (2) Partial evaluations using a submodule for the predictor likelihood for all of the tanks on the FGWL that had been flagged previously by Whitney (1995)

  10. 75 FR 66735 - National Fire Protection Association (NFPA): Request for Comments on NFPA's Codes and Standards

    Science.gov (United States)

    2010-10-29

    ... 59A Standard for the P Production, Storage, and Handling of Liquefied Natural Gas (LNG). NFPA 75... Horizontally in Fire Resistance-Rated Floor Systems. NFPA 385 Standard for Tank P Vehicles for Flammable and Combustible Liquids. NFPA 497 Recommended Practice P for the Classification of Flammable Liquids, Gases, or...

  11. 46 CFR 111.105-32 - Bulk liquefied flammable gas and ammonia carriers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bulk liquefied flammable gas and ammonia carriers. 111... gas and ammonia carriers. (a) Each vessel that carries bulk liquefied flammable gases or ammonia as a.... (2) The term “gas-dangerous” does not include the weather deck of an ammonia carrier. (c) Each...

  12. The primary factor for suture configuration at rotator cuff repair: Width of mattress or distance from tear edge

    Directory of Open Access Journals (Sweden)

    Onur Hapa

    2016-08-01

    Conclusion: Bite size from the edge of the tendon seems to be more important than the width of the mattress. The curve of the suture passing device may also have an effect on the strength of the suture tendon interface.

  13. BFR Electrolyte Additive Safety and Flammability Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Allcorn, Eric [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-13

    Lithium-ion battery safety is a critical issue in the adoption of the chemistry to larger scale applications such as transportation and stationary storage. One of the critical components impacting the safety of lithium-ion batteries is their use of highly flammable organic electrolytes. In this work, brominated flame retardants (BFR’s) – an existing class of flame retardant materials – are incorporated as additives to lithium-ion battery electrolytes with the intention to reduce the electrolyte flammability and thereby improve safety. There are a few critical needs for a successful electrolyte additive: solubility in the electrolyte, electrochemical stability over the range of battery operation, and minimal detrimental effects on battery performance. Those detrimental effects can take the form of electrolyte specific impacts, such as a reduction in conductivity, or electrode impacts, such as SEI-layer modification or chemical instability to the active material. In addition to these needs, the electrolyte additive also needs to achieve its intended purpose, which in this case is to reduce the flammability of the electrolyte. For the work conducted as part of this SPP agreement three separate BFR materials were provided by Albemarle to be tested by Sandia as additives in a traditional lithium-ion battery electrolyte. The provided BFR materials were tribromo-neopentyl alcohol, tetrabromo bisphenol A, and tribromoethylene. These materials were incorporated as separate 4 wt.% additives into a traditional lithium-ion battery electrolyte and compared to said traditional electrolyte, designated Gen2.

  14. 46 CFR 182.480 - Flammable vapor detection systems.

    Science.gov (United States)

    2010-10-01

    ... 100 GROSS TONS) MACHINERY INSTALLATION Specific Machinery Requirements § 182.480 Flammable vapor... permit calibration in a vapor free atmosphere. (g) Electrical connections, wiring, and components for a...

  15. DWPF Melter Off-Gas Flammability Assessment for Sludge Batch 9

    Energy Technology Data Exchange (ETDEWEB)

    Choi, A. S. [Savannah River Site (SRS), Aiken, SC (United States)

    2016-07-11

    The slurry feed to the Defense Waste Processing Facility (DWPF) melter contains several organic carbon species that decompose in the cold cap and produce flammable gases that could accumulate in the off-gas system and create potential flammability hazard. To mitigate such a hazard, DWPF has implemented a strategy to impose the Technical Safety Requirement (TSR) limits on all key operating variables affecting off-gas flammability and operate the melter within those limits using both hardwired/software interlocks and administrative controls. The operating variables that are currently being controlled include; (1) total organic carbon (TOC), (2) air purges for combustion and dilution, (3) melter vapor space temperature, and (4) feed rate. The safety basis limits for these operating variables are determined using two computer models, 4-stage cold cap and Melter Off-Gas (MOG) dynamics models, under the baseline upset scenario - a surge in off-gas flow due to the inherent cold cap instabilities in the slurry-fed melter.

  16. Methods development for measuring and classifying flammability/combustibility of refrigerants. Interim report, task 2 - test plan

    Energy Technology Data Exchange (ETDEWEB)

    Heinonen, E.W.; Tapscott, R.E. [Univ. of New Mexico, Albuquerque, NM (United States)

    1994-07-01

    Regulations on alternative refrigerants and concerns for the environment are forcing the refrigeration industry to consider the use of potentially flammable fluids to replace CFC fluids currently in use. The objectives of this program are to establish the conditions under which refrigerants and refrigerant blends exhibit flammability and to develop appropriate methods to measure flammability.

  17. Estimation and Uncertainty Analysis of Flammability Properties of Chemicals using Group-Contribution Property Models

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Abildskov, Jens; Sin, Gürkan

    Process safety studies and assessments rely on accurate property data. Flammability data like the lower and upper flammability limit (LFL and UFL) play an important role in quantifying the risk of fire and explosion. If experimental values are not available for the safety analysis due to cost...... or time constraints, property prediction models like group contribution (GC) models can estimate flammability data. The estimation needs to be accurate, reliable and as less time consuming as possible. However, GC property prediction methods frequently lack rigorous uncertainty analysis. Hence....... In this study, the MG-GC-factors are estimated using a systematic data and model evaluation methodology in the following way: 1) Data. Experimental flammability data is used from AIChE DIPPR 801 Database. 2) Initialization and sequential parameter estimation. An approximation using linear algebra provides...

  18. Flammable gas project expert elicitation results for Hanford Site double-shell tanks

    International Nuclear Information System (INIS)

    Bratzel, D.R.

    1998-01-01

    This report documents the results of the second phase of parameter quantification by the flammable gas expert panel. This second phase is focused on the analysis of flammable gas accidents in the Hanford Site double-shell tanks. The first phase of parameter quantification, performed in 1997 was focused on the analysis of Hanford single-shell tanks

  19. 14 CFR Appendix N to Part 25 - Fuel Tank Flammability Exposure and Reliability Analysis

    Science.gov (United States)

    2010-01-01

    ..., Definitions). A non-flammable ullage is one where the fuel-air vapor is too lean or too rich to burn or is... Office for approval the fuel tank flammability analysis, including the airplane-specific parameters...

  20. Review on flammability of biofibres and biocomposites

    CSIR Research Space (South Africa)

    Mngomezulu, ME

    2013-10-01

    Full Text Available The subject on flammability properties of natural fibre-reinforced biopolymer composites has not been broadly researched. This is not only evidenced by the minimal use of biopolymer composites and/or blends in different engineering areas where fire...

  1. Pressure ulcers prevention efficacy of an alternating pressure air mattress in elderly patients: E²MAO a randomised study.

    Science.gov (United States)

    Sauvage, P; Touflet, M; Pradere, C; Portalier, F; Michel, J-M; Charru, P; Passadori, Y; Fevrier, R; Hallet-Lezy, A-M; Beauchêne, F; Scherrer, B

    2017-06-02

    Our aim was to compare Axtair One, an alternating pressure air mattress (APAM), with a viscoelastic foam mattress (VFM) in elderly patients at moderate to high risk of developing pressure ulcers (PUs). A randomised, controlled, superiority, parallel-group, open-label, multicentre study, was conducted, between February 2012 and March 2015, in nine French, medium- and long-term stay facilities. Eligible patients were aged 70 and over, had no PUs on enrolment, were bedridden for at least 15 hours per day, had reduced mobility, an absent or minimal positioning capability, a Braden score 12 and a Karnofsky score elderly patients, bedridden for more than 15 hours per day, severely dependent, at moderate-to high-risk of PUs, with an instantaneous risk for the appearance of PUs 7.57 times greater in the VFM group than in the APAM group. This study provides descriptive information and evidence for practice.

  2. Tests of Flammability of Cotton Fabrics and Expected Skin Burns in Microgravity

    Science.gov (United States)

    Cavanagh, Jane M.; Torvi, David A.; Gabriel, Kamiel S.; Ruff, Gary A.

    2004-01-01

    During a shuttle launch and other portions of space flight, astronauts wear specialized flame resistant clothing. However during most of their missions on board the Space Shuttle or International Space Station, astronauts wear ordinary clothing, such as cotton shirts and pants. As the behaviour of flames is considerably different in microgravity than under earth s gravity, fabrics are expected to burn in a different fashion in microgravity than when tested on earth. There is interest in determining how this change in burning behaviour may affect times to second and third degree burn of human skin, and how the results of standard fabric flammability tests conducted under earth s gravity correlate with the expected fire behaviour of textiles in microgravity. A new experimental apparatus was developed to fit into the Spacecraft Fire Safety Facility (SFSF), which is used on NASA s KC-135 low gravity aircraft. The new apparatus was designed to be similar to the apparatus used in standard vertical flammability tests of fabrics. However, rather than using a laboratory burner, the apparatus uses a hot wire system to ignite 200 mm high by 80 mm wide fabric specimens. Fabric temperatures are measured using thermocouples and/or an infrared imaging system, while flame spread rates are measured using real time observations or video. Heat flux gauges are placed between 7 and 13 mm away from the fabric specimen, so that heat fluxes from the burning fabric to the skin can be estimated, along with predicted times required to produce skin burns.

  3. Progress toward mitigation of flammable gas Tank 241-SY-101

    International Nuclear Information System (INIS)

    Lentsch, J.W.; Babad, H.; Hanson, C.E.; Kirch, N.W.

    1994-01-01

    The mixing pump installed in Hanford Site tank 241-SY-101 has been shown to be effective in releasing flammable gases in a controlled manner. This controlled release of gas prevents the accumulation and episodic release above flammable limits. More work needs to be done to optimize the pumping operation, and to evaluate the long-term effects of mixing so as to assure that no undesirable changes have occurred to the waste. Other alternative mitigation concepts are still being evaluated as a backup to mixing

  4. 16 CFR 1145.3 - Extremely flammable contact adhesives; risk of burns from explosive vapor ignition and flashback...

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Extremely flammable contact adhesives; risk... TO OTHER ACTS UNDER THE CONSUMER PRODUCT SAFETY ACT § 1145.3 Extremely flammable contact adhesives... associated with certain extremely flammable contact adhesives under the Consumer Product Safety Act rather...

  5. Flammable gas program topical report

    International Nuclear Information System (INIS)

    Johnson, G.D.

    1996-01-01

    The major emphasis of this report is to describe what has been learned about the generation, retention, and release of flammable gas mixtures in high-level waste tanks. A brief overview of efforts to characterize the gas composition will be provided. The report also discusses what needs to be learned about the phenomena, how the Unreviewed Safety Question will be closed, and the approach for removing tanks from the Watch List

  6. Species mixture effects on flammability across plant phylogeny: the importance of litter particle size and the special role for non-Pinus Pinaceae.

    Science.gov (United States)

    Zhao, Weiwei; Cornwell, William K; van Pomeren, Marinda; van Logtestijn, Richard S P; Cornelissen, Johannes H C

    2016-11-01

    Fire affects and is affected by plants. Vegetation varies in flammability, that is, its general ability to burn, at different levels of ecological organization. To scale from individual plant traits to community flammability states, understanding trait effects on species flammability variation and their interaction is important. Plant traits are the cumulative result of evolution and they show, to differing extents, phylogenetic conservatism. We asked whether phylogenetic distance between species predicts species mixture effects on litterbed flammability. We conducted controlled laboratory burns for 34 phylogenetically wide-ranging species and 34 random two-species mixtures from them. Generally, phylogenetic distance did not predict species mixture effects on flammability. Across the plant phylogeny, most species were flammable except those in the non- Pinus Pinaceae, which shed small needles producing dense, poorly ventilated litterbeds above the packing threshold and therefore nonflammable. Consistently, either positive or negative dominance effects on flammability of certain flammable or those non-flammable species were found in mixtures involving the non- Pinus Pinaceae. We demonstrate litter particle size is key to explaining species nonadditivity in fuelbed flammability. The potential of certain species to influence fire disproportionately to their abundance might increase the positive feedback effects of plant flammability on community flammability state if flammable species are favored by fire.

  7. 40 CFR 280.20 - Performance standards for new UST systems.

    Science.gov (United States)

    2010-07-01

    ..., or spills and overfills for as long as the UST system is used to store regulated substances, all... of Canada CAN4-S603-M85, “Standard for Steel Underground Tanks for Flammable and Combustible Liquids... Flammable and Combustible Liquids,” and CAN4-S631-M84, “Isolating Bushings for Steel Underground Tanks...

  8. Textiles: Some technocal information and data III: Low flammable and other high performance fibres

    CSIR Research Space (South Africa)

    Hunter, L

    1978-07-01

    Full Text Available What it meant by the flammability of a texttile material? What exactly are the meaning of such term as "non-burning", "fire resistant", "self-extinquishing","non-combustible","flameproof",etc? Unfortunately the flammability properties to which...

  9. Operational experience in mitigating flammable gas releases from Hanford Site Tank 241-SY-101

    International Nuclear Information System (INIS)

    Lentsch, J.W.; Babad, H.; Kirch, N.W.

    1995-01-01

    Flammable gases consisting of hydrogen, nitrous oxide, ammonia, and methane are periodically released from Hanford Site waste tank 241-SY-101 at concentrations above the flammable limit. A large mixer pump installed in the tank in 1993 has effectively mitigated this problem by continuously releasing small amounts of the flammable gases at the rate they are generated. Tank 241-SY-101 is also equipped with multiple high-sensitivity gas monitoring systems and level detection systems to measure the quantity of gas that is retained in and released from the waste

  10. Microgravity Flammability Experiments for Spacecraft Fire Safety

    DEFF Research Database (Denmark)

    Legros, Guillaume; Minster, Olivier; Tóth, Balazs

    2012-01-01

    As fire behaviour in manned spacecraft still remains poorly understood, an international topical team has been created to design a validation experiment that has an unprecedented large scale for a microgravity flammability experiment. While the validation experiment is being designed for a re-sup...

  11. 30 CFR 77.1103 - Flammable liquids; storage.

    Science.gov (United States)

    2010-07-01

    ... storage tanks shall be mounted securely on firm foundations. Outlet piping shall be provided with flexible connections or other special fittings to prevent adverse effects from tank settling. (c) Fuel lines shall be... hazards. (d) Areas surrounding flammable-liquid storage tanks and electric substations and transformers...

  12. The ring of fire: the relative importance of fuel packing versus intrinsic leaf flammability

    NARCIS (Netherlands)

    Grootemaat, S.; Wright, I.J.; Cornelissen, J.H.C.; Viegas, D.X.

    2014-01-01

    Two different experimental set-ups were used to disentangle the relative importance of intrinsic leaf traits versus fuel packing for the flammability in fuel beds. Dried leaves from 25 Australian perennial species were burnt in fuel bed rings under controlled conditions. The flammability parameters

  13. Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients' temperatures in prehospital emergency care - an intervention study.

    Science.gov (United States)

    Aléx, Jonas; Karlsson, Stig; Björnstig, Ulf; Saveman, Britt-Inger

    2015-01-01

    Background The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients' exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients' temperatures in the prehospital emergency care. Methods A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30) was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30) no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS), subjective comments on cold experiences, and finger, ear and air temperatures. Results Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001) but decreased in the control group (p=0.014). A significant higher proportion (57%) of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, pthermal comfort and may prevent the negative consequences of cold stress.

  14. Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients' temperatures in prehospital emergency care--an intervention study.

    Science.gov (United States)

    Aléx, Jonas; Karlsson, Stig; Björnstig, Ulf; Saveman, Britt-Inger

    2015-01-01

    The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients' exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients' temperatures in the prehospital emergency care. A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30) was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30) no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS), subjective comments on cold experiences, and finger, ear and air temperatures. Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001) but decreased in the control group (p=0.014). A significant higher proportion (57%) of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, pthermal comfort and may prevent the negative consequences of cold stress.

  15. Analysis of flammability in the attached buildings to containment under severe accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, J.C. de la, E-mail: juan-carlos.de-la-rosa-blul@ec.europa.eu [European Commission Joint Research Centre (Netherlands); Fornós, Joan, E-mail: jfornosh@anacnv.com [Asociación Nuclear Ascó-Vandellós (Spain)

    2016-11-15

    Highlights: • Analysis of flammability conditions in buildings outside containment. • Stepwise approach easily applicable for any kind of containment and attached buildings layout. • Detailed application for real plant conditions has been included. - Abstract: Right after the events unfolded in Fukushima Daiichi, the European Union countries agreed in subjecting Nuclear Power Plants to Stress Tests as developed by WENRA and ENSREG organizations. One of the results as implemented in many European countries derived from such tests consisted of mandatory technical instructions issued by nuclear regulatory bodies on the analysis of potential risk of flammable gases in attached buildings to containment. The current study addresses the key aspects of the analysis of flammable gases leaking to auxiliary buildings attached to Westinghouse large-dry PWR containment for the specific situation where mitigating systems to prevent flammable gases to grow up inside containment are available, and containment integrity is preserved – hence avoiding isolation system failure. It also provides a full practical exercise where lessons learned derived from the current study – hence limited to the imposed boundary conditions – are applied. The leakage of gas from the containment to the support buildings is based on separate calculations using the EPRI-owned Modular Accident Analysis Program, MAAP4.07. The FATE™ code (facility Flow, Aerosol, Thermal, and Explosion) was used to model the transport and distribution of leaked flammable gas (H{sub 2} and CO) in the penetration buildings. FATE models the significant mixing (dilution) which occurs as the released buoyant gas rises and entrains air. Also, FATE accounts for the condensation of steam on room surfaces, an effect which acts to concentrate flammable gas. The results of the analysis show that during a severe accident, flammable conditions are unlikely to occur in compartmentalized buildings such as the one used in the

  16. Analysis of flammability in the attached buildings to containment under severe accident conditions

    International Nuclear Information System (INIS)

    Rosa, J.C. de la; Fornós, Joan

    2016-01-01

    Highlights: • Analysis of flammability conditions in buildings outside containment. • Stepwise approach easily applicable for any kind of containment and attached buildings layout. • Detailed application for real plant conditions has been included. - Abstract: Right after the events unfolded in Fukushima Daiichi, the European Union countries agreed in subjecting Nuclear Power Plants to Stress Tests as developed by WENRA and ENSREG organizations. One of the results as implemented in many European countries derived from such tests consisted of mandatory technical instructions issued by nuclear regulatory bodies on the analysis of potential risk of flammable gases in attached buildings to containment. The current study addresses the key aspects of the analysis of flammable gases leaking to auxiliary buildings attached to Westinghouse large-dry PWR containment for the specific situation where mitigating systems to prevent flammable gases to grow up inside containment are available, and containment integrity is preserved – hence avoiding isolation system failure. It also provides a full practical exercise where lessons learned derived from the current study – hence limited to the imposed boundary conditions – are applied. The leakage of gas from the containment to the support buildings is based on separate calculations using the EPRI-owned Modular Accident Analysis Program, MAAP4.07. The FATE™ code (facility Flow, Aerosol, Thermal, and Explosion) was used to model the transport and distribution of leaked flammable gas (H_2 and CO) in the penetration buildings. FATE models the significant mixing (dilution) which occurs as the released buoyant gas rises and entrains air. Also, FATE accounts for the condensation of steam on room surfaces, an effect which acts to concentrate flammable gas. The results of the analysis show that during a severe accident, flammable conditions are unlikely to occur in compartmentalized buildings such as the one used in the

  17. Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring.

    Science.gov (United States)

    Sartiano, Demetrio; Sales, Salvador

    2017-12-13

    The aim of this paper is to report the design of a low-cost plastic optical fiber (POF) pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm) and a silicon light sensor. The Super ESKA ® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2-5 s (0.2-0.5 Hz). The sensor has a resolution of force applied on a single point of 2.2-4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.

  18. Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring

    Directory of Open Access Journals (Sweden)

    Demetrio Sartiano

    2017-12-01

    Full Text Available The aim of this paper is to report the design of a low-cost plastic optical fiber (POF pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm and a silicon light sensor. The Super ESKA® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2–5 s (0.2–0.5 Hz. The sensor has a resolution of force applied on a single point of 2.2–4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.

  19. DOE/DOE Tight Oil Flammability & Transportation Spill Safety

    Energy Technology Data Exchange (ETDEWEB)

    Lord, David L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-12-01

    This presentation describes crude oils, their phase behavior, the SPR vapor pressure program, and presents data comparisons from various analytical techniques. The overall objective is to describe physical properties of crude oil relevant to flammability and transport safety

  20. The effect of hydrogen enrichment towards the flammability limits of natural gas in conventional combustion

    International Nuclear Information System (INIS)

    Izirwan Izhab; Nur Syuhada Mohd Shokri; Nurul Saadah Sulaiman; Mohd Zulkifli Mohamad Noor; Siti Zubaidah Sulaiman; Rosmawati Naim; Norida Ridzuan, Mohd Masri Razak; Abdul Halim Abdul Razik; Zulkafli Hassan

    2010-01-01

    The use of hydrogenated fuels shows a considerable promise for the applications in gas turbines and internal combustion engines. The aims of this study are to determine the flammability limits of natural gas/ air mixtures and to investigate the effect of hydrogen enrichment on the flammability limits of natural gas/ air mixtures up to 60 vol % of hydrogen/fuel volume ratio at atmospheric pressure and ambient temperature. The experiments were performed in a 20 L closed explosion vessel where the mixtures were ignited by using a spark permanent wire that was placed at the centre of the vessel. The pressure-time variations during explosions of natural gas/ air mixtures in an explosion vessel were recorded. Moreover, the explosion pressure data is used to determine the flammability limits that flame propagation is considered to occur if explosion pressure is greater than 0.1 bar. Therefore, in this study, the results show that the range of flammability limits are from 6 vol % to 15 vol % and by the addition of hydrogen in natural gas proved to extend the initial lower flammability limit of 6 vol % to 2 vol % of methane. (author)

  1. Engineering task plan for flammable gas atmosphere mobile color video camera systems

    International Nuclear Information System (INIS)

    Kohlman, E.H.

    1995-01-01

    This Engineering Task Plan (ETP) describes the design, fabrication, assembly, and testing of the mobile video camera systems. The color video camera systems will be used to observe and record the activities within the vapor space of a tank on a limited exposure basis. The units will be fully mobile and designed for operation in the single-shell flammable gas producing tanks. The objective of this tank is to provide two mobile camera systems for use in flammable gas producing single-shell tanks (SSTs) for the Flammable Gas Tank Safety Program. The camera systems will provide observation, video recording, and monitoring of the activities that occur in the vapor space of applied tanks. The camera systems will be designed to be totally mobile, capable of deployment up to 6.1 meters into a 4 inch (minimum) riser

  2. Fires in the Cenozoic: a late flowering of flammable ecosystems

    Directory of Open Access Journals (Sweden)

    William John Bond

    2015-01-01

    Full Text Available Modern flammable ecosystems include tropical and subtropical savannas, steppe grasslands, boreal forests and temperate sclerophyll shrublands. Despite the apparent fiery nature of much contemporary vegetation, terrestrial fossil evidence would suggest we live in a time of low fire activity relative to the deep past. The inertinite content of coal, fossil charcoal, is strikingly low from the Eocene to the Pleistocene and no charcoalified mesofossils have been reported for the Cenozoic. Marine cores have been analysed for charcoal in the North Pacific, the north and south Atlantic off Africa, and the south China sea. These tell a different story with the oldest records indicating low levels of fire activity from the Eocene but a surge of fire from the late Miocene (~7 Ma. Phylogenetic studies of woody plants adapted to frequent savanna fires show them beginning to appear from the Late Miocene with peak origins in the late Pliocene in both South American and African lineages. Phylogenetic studies indicate ancient origins (60 Ma+ for clades characteristic of flammable sclerophyll vegetation from Australia and the Cape region of South Africa. However, as for savannas, there was a surge of speciation from the Late Miocene associated with the retreat of closed fire-intolerant forests. The wide geographic spread of increased fire activity in the last few million years suggests a global cause. However none of the potential global factors (oxygen, rainfall seasonality, CO2 , novel flammable growth forms provides an adequate explanation as yet. The global patterns and processes of fire and flammable vegetation in the Cenozoic, especially since the Late Miocene, deserve much more attention to better understand fire in the earth system.

  3. Fires in the Cenozoic: a late flowering of flammable ecosystems.

    Science.gov (United States)

    Bond, William J

    2014-01-01

    Modern flammable ecosystems include tropical and subtropical savannas, steppe grasslands, boreal forests, and temperate sclerophyll shrublands. Despite the apparent fiery nature of much contemporary vegetation, terrestrial fossil evidence would suggest we live in a time of low fire activity relative to the deep past. The inertinite content of coal, fossil charcoal, is strikingly low from the Eocene to the Pleistocene and no charcoalified mesofossils have been reported for the Cenozoic. Marine cores have been analyzed for charcoal in the North Pacific, the north and south Atlantic off Africa, and the south China sea. These tell a different story with the oldest records indicating low levels of fire activity from the Eocene but a surge of fire from the late Miocene (~7 Ma). Phylogenetic studies of woody plants adapted to frequent savanna fires show them beginning to appear from the Late Miocene with peak origins in the late Pliocene in both South American and African lineages. Phylogenetic studies indicate ancient origins (60 Ma+) for clades characteristic of flammable sclerophyll vegetation from Australia and the Cape region of South Africa. However, as for savannas, there was a surge of speciation from the Late Miocene associated with the retreat of closed fire-intolerant forests. The wide geographic spread of increased fire activity in the last few million years suggests a global cause. However, none of the potential global factors (oxygen, rainfall seasonality, CO2, novel flammable growth forms) provides an adequate explanation as yet. The global patterns and processes of fire and flammable vegetation in the Cenozoic, especially since the Late Miocene, deserve much more attention to better understand fire in the earth system.

  4. Characterization strategy for the flammable gas safety issue

    International Nuclear Information System (INIS)

    Stewart, C.W.; Brewster, M.E.; Roberts, J.S.

    1997-06-01

    The characterization strategy for resolving the flammable gas safety issue for Hanford waste tanks is based on a structured logic diagram (SLD) that displays the outcomes necessary to reach the desired goal of making flammable gas risk acceptable. The diagram provides a structured path that can identify all information inputs, data as well as models, needed to achieve the goal. Tracing the path from need to outcome provides an immediate and clear justification and defense of a specific need. The diagram itself is a open-quote picture of a risk calculation close-quote and forms the basis for a quantitative model of risk. The SLID, with the risk calculation, identifies options for characterization, mitigation, and controls that have the maximum effect in reducing risk. It provides quantitative input to risk-based decision making so that options are chosen for maximum impact at least cost

  5. Outlier treatment for improving parameter estimation of group contribution based models for upper flammability limit

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Abildskov, Jens; Sin, Gürkan

    2015-01-01

    Flammability data is needed to assess the risk of fire and explosions. This study presents a new group contribution (GC) model to predict the upper flammability limit UFL oforganic chemicals. Furthermore, it provides a systematic method for outlier treatment inorder to improve the parameter...

  6. Effect of melamine phosphate on the thermal stability and flammability of bio-based polyurethanes

    International Nuclear Information System (INIS)

    Yakushin, Vladimir; Sevastyanova, Irina; Vilsone, Dzintra; Avots, Andris

    2016-01-01

    The effect of melamine phosphate (MP) on the thermal stability of bio-based polyurethane and the flammability parameters of wood samples with polyurethane coatings was studied. Thermogravimetric analysis and cone calorimeter test at a heat flux of 35 kW/m 2 were used for this purpose. The main characteristics of the thermal stability and flammability of the coating with addition of MP were compared with the characteristics of analogous coatings with addition of ammonium polyphosphate (APP), as well as APP in combination with melamine. It was found that the use of MP as an intumescent additive allows a considerable decrease of most of the flammability parameters of the polyurethane based on tall oil fatty acids, like APP. To reach the maximum effect, it is enough to load in the polyurethane 20% of MP. In contrast to APP, MP reduces also the smoke release of the samples. Using MP in combination with APP at definite weight ratios, it is possible to essentially reduce the flammability parameters of polyurethane coatings, such as PHRR, THR and MARHE. (paper)

  7. The Chemistry of Flammable Gas Generation

    International Nuclear Information System (INIS)

    ZACH, J.J.

    2000-01-01

    The document collects information from field instrumentation, laboratory tests, and analytical models to provide a single source of information on the chemistry of flammable gas generation at the Hanford Site. It considers the 3 mechanisms of formation: radiolysis, chemical reactions, and thermal generation. An assessment of the current models for gas generation is then performed. The results are that the various phenomena are reasonably understood and modeled compared to field data

  8. The Chemistry of Flammable Gas Generation

    Energy Technology Data Exchange (ETDEWEB)

    ZACH, J.J.

    2000-10-30

    The document collects information from field instrumentation, laboratory tests, and analytical models to provide a single source of information on the chemistry of flammable gas generation at the Hanford Site. It considers the 3 mechanisms of formation: radiolysis, chemical reactions, and thermal generation. An assessment of the current models for gas generation is then performed. The results are that the various phenomena are reasonably understood and modeled compared to field data.

  9. 24 CFR 51.203 - Safety standards.

    Science.gov (United States)

    2010-04-01

    ... Conventional Fuels or Chemicals of an Explosive or Flammable Nature § 51.203 Safety standards. The following... facilities or areas shall not exceed 0.5 psi. (c) If a hazardous substance constitutes both a thermal...

  10. Condensation heat transfer coefficients of flammable refrigerants on various enhanced tubes

    International Nuclear Information System (INIS)

    Park, Ki Jung; Jung, Dong Soo

    2005-01-01

    In this study, external condensation Heat Transfer Coefficients (HTCs) of six flammable refrigerants of propylene (R1270), propane (R290), isobutane (R600a), butane (R600), dimethylether (RE170), and HFC32 were measured at the vapor temperature of 39 .deg. C on a 1023 fpm low fin and turbo-C tubes. All data were taken under the heat flux of 32∼116 and 42∼142 kW/m 2 for the low fin and turbo-C tubes respectively. Flammable refrigerants' data obtained on enhanced tubes showed a typical trend that external condensation HTCs decrease with increasing wall subcooling. HFC32 and DME showed up to 30% higher HTCs than those of HCFC22 due to their excellent thermophysical properties. Propylene, propane, isobutane, and butane showed similar or lower HTCs than those of HCFC22. Beatty and Katz' correlation predicted the HTCs of the flammable refrigerants obtained on a low fin tube within a mean deviation of 7.3%. Turbo-C tube showed the best performance due to its 3 dimensional surface geometry for fast removal of condensate

  11. A Comparison of Cervical Spine Motion After Immobilization With a Traditional Spine Board and Full-Body Vacuum-Mattress Splint.

    Science.gov (United States)

    Etier, Brian E; Norte, Grant E; Gleason, Megan M; Richter, Dustin L; Pugh, Kelli F; Thomson, Keith B; Slater, Lindsay V; Hart, Joe M; Brockmeier, Stephen F; Diduch, David R

    2017-12-01

    The National Athletic Trainers' Association (NATA) advocates for cervical spine immobilization on a rigid board or vacuum splint and for removal of athletic equipment before transfer to an emergency medical facility. To (1) compare triplanar cervical spine motion using motion capture between a traditional rigid spine board and a full-body vacuum splint in equipped and unequipped athletes, (2) assess cervical spine motion during the removal of a football helmet and shoulder pads, and (3) evaluate the effect of body mass on cervical spine motion. Controlled laboratory study. Twenty healthy male participants volunteered for this study to examine the influence of immobilization type and presence of equipment on triplanar angular cervical spine motion. Three-dimensional cervical spine kinematics was measured using an electromagnetic motion analysis system. Independent variables included testing condition (static lift and hold, 30° tilt, transfer, equipment removal), immobilization type (rigid, vacuum-mattress), and equipment (on, off). Peak sagittal-, frontal-, and transverse-plane angular motions were the primary outcome measures of interest. Subjective ratings of comfort and security did not differ between immobilization types ( P > .05). Motion between the rigid board and vacuum splint did not differ by more than 2° under any testing condition, either with or without equipment. In removing equipment, the mean peak motion ranged from 12.5° to 14.0° for the rigid spine board and from 11.4° to 15.4° for the vacuum-mattress splint, and more transverse-plane motion occurred when using the vacuum-mattress splint compared with the rigid spine board (mean difference, 0.14 deg/s [95% CI, 0.05-0.23 deg/s]; P = .002). In patients weighing more than 250 lb, the rigid board provided less motion in the frontal plane ( P = .027) and sagittal plane ( P = .030) during the tilt condition and transfer condition, respectively. The current study confirms similar motion in the

  12. A flammability and combustion model for integrated accident analysis

    International Nuclear Information System (INIS)

    Plys, M.G.; Astleford, R.D.; Epstein, M.

    1988-01-01

    A model for flammability characteristics and combustion of hydrogen and carbon monoxide mixtures is presented for application to severe accident analysis of Advanced Light Water Reactors (ALWR's). Flammability of general mixtures for thermodynamic conditions anticipated during a severe accident is quantified with a new correlation technique applied to data for several fuel and inertant mixtures and using accepted methods for combining these data. Combustion behavior is quantified by a mechanistic model consisting of a continuity and momentum balance for the burned gases, and considering an uncertainty parameter to match the idealized process to experiment. Benchmarks against experiment demonstrate the validity of this approach for a single recommended value of the flame flux multiplier parameter. The models presented here are equally applicable to analysis of current LWR's. 21 refs., 16 figs., 6 tabs

  13. Flow Effects on the Flammability Diagrams of Solid Fuels: Microgravity Influence on Ignition Delay

    Science.gov (United States)

    Cordova, J. L.; Walther, D. C.; Fernandez-Pello, A. C.; Steinhaus, T.; Torero, J. L.; Quintere, J. G.; Ross, H. D.

    1999-01-01

    The possibility of an accidental fire in space-based facilities is a primary concern of space exploration programs. Spacecraft environments generally present low velocity air currents produced by ventilation and heating systems (of the order of 0.1 m/s), and fluctuating oxygen concentrations around that of air due to CO2 removal systems. Recent experiments of flame spread in microgravity show the spread rate to be faster and the limiting oxygen concentration lower than in normal-gravity. To date, there is not a material flammability-testing protocol that specifically addresses issues related to microgravity conditions. The present project (FIST) aims to establish a testing methodology that is suitable for the specific conditions of reduced gravity. The concepts underlying the operation of the LIFT apparatus, ASTM-E 1321-93, have been used to develop the Forced-flow Ignition and flame-Spread Test (FIST). As in the LIFT, the FIST is used to obtain the flammability diagrams of the material, i.e., graphs of ignition delay time and flame spread rate as a function of the externally applied radiant flux, but under forced flow rather than natural convection conditions, and for different oxygen concentrations. Although the flammability diagrams are similar, the flammability properties obtained with the FIST are found to depend on the flow characteristics. A research program is currently underway with the purpose of implementing the FIST as a protocol to characterize the flammability performance of solid materials to be used in microgravity facilities. To this point, tests have been performed with the FIST apparatus in both normal-gravity and microgravity conditions to determine the effects of oxidizer flow characteristics on the flammability diagrams of polymethylmethacrylate (PMMA) fuel samples. The experiments are conducted at reduced gravity in a KC- 135 aircraft following a parabolic flight trajectory that provides up to 25 seconds of low gravity. The objective of the

  14. Equipment design guidance document for flammable gas waste storage tank new equipment

    International Nuclear Information System (INIS)

    Smet, D.B.

    1996-01-01

    This document is intended to be used as guidance for design engineers who are involved in design of new equipment slated for use in Flammable Gas Waste Storage Tanks. The purpose of this document is to provide design guidance for all new equipment intended for application into those Hanford storage tanks in which flammable gas controls are required to be addressed as part of the equipment design. These design criteria are to be used as guidance. The design of each specific piece of new equipment shall be required, as a minimum to be reviewed by qualified Unreviewed Safety Question evaluators as an integral part of the final design approval. Further Safety Assessment may be also needed. This guidance is intended to be used in conjunction with the Operating Specifications Documents (OSDs) established for defining work controls in the waste storage tanks. The criteria set forth should be reviewed for applicability if the equipment will be required to operate in locations containing unacceptable concentrations of flammable gas

  15. Summary of tank information relating salt well pumping to flammable gas safety issues

    International Nuclear Information System (INIS)

    Caley, S.M.; Mahoney, L.A.; Gauglitz, P.A.

    1996-09-01

    The Hanford Site has 149 single-shell tanks (SSTs) containing radioactive wastes that are complex mixes of radioactive and chemical products. Active use of these SSTs was phased out completely by November 1980, and the first step toward final disposal of the waste in the SSTs is interim stabilization, which involves removing essentially all of the drainable liquid from the tank. Stabilization can be achieved administratively, by jet pumping to remove drainable interstitial liquid, or by supernatant pumping. To date, 116 tanks have been declared interim stabilized; 44 SSTs have had drainable liquid removed by salt well jet pumping. Of the 149 SSTs, 19 are on the Flammable Gas Watch List (FGWL) because the waste in these tanks is known or suspected, in all but one case, to generate and retain mixtures of flammable gases, including; hydrogen, nitrous oxide, and ammonia. Salt well pumping to remove the drainable interstitial liquid from these SSTs is expected to cause the release of much of the retained gas, posing a number of safety concerns. The scope of this work is to collect and summarize information, primarily tank data and observations, that relate salt well pumping to flammable gas safety issues. While the waste within FGWL SSTs is suspected offering flammable gases, the effect of salt well pumping on the waste behavior is not well understood. This study is being conducted for the Westinghouse Hanford Company as part of the Flammable Gas Project at the Pacific Northwest National Laboratory (PNNL). Understanding the historical tank behavior during and following salt well pumping will help to resolve the associated safety issues

  16. Project W-030 flammable gas verification monitoring test

    International Nuclear Information System (INIS)

    BARKER, S.A.

    1999-01-01

    This document describes the verification monitoring campaign used to document the ability of the new ventilation system to mitigate flammable gas accumulation under steady state tank conditions. This document reports the results of the monitoring campaign. The ventilation system configuration, process data, and data analysis are presented

  17. Influence of Knits Structure on Flammability and Comfortability

    Directory of Open Access Journals (Sweden)

    Mikučionienė D.

    2014-12-01

    Full Text Available Investigations of the influence of the knit structure, i.e. the loop length and the number of yarns in a loop, on flammability and comfortability are presented in this paper. The investigations were carried out using single jersey knits from Delta TA 18 tex × 2 yarns with five variants of a loop length. Single yarn as well as folded yarn from two single yarns was used in the investigations. Comparison of the results of single-layer knits flammability and air permeability with those of multilayer packet was made. The results obtained show that an increase in the loop length of the knit increases their permeability to air and decreases the burning time as well as increase in the number of layers decreases the air permeability and increases the burning time. Moreover, the similar burning time with significantly different permeability to air can be achieved changing the basic knitting parameters, i.e. the loop length and/or the yarn linear density.

  18. 16 CFR 1500.46 - Method for determining flashpoint of extremely flammable contents of self-pressurized containers.

    Science.gov (United States)

    2010-01-01

    ... extremely flammable contents of self-pressurized containers. 1500.46 Section 1500.46 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS HAZARDOUS SUBSTANCES AND... extremely flammable contents of self-pressurized containers. Use the apparatus described in § 1500.43a. Use...

  19. A Randomized, Crossover Trial of a Novel Sound-to-Sleep Mattress Technology in Children with Autism and Sleep Difficulties.

    Science.gov (United States)

    Frazier, Thomas W; Krishna, Jyoti; Klingemier, Eric; Beukemann, Mary; Nawabit, Rawan; Ibrahim, Sally

    2017-01-15

    This preliminary study investigated the tolerability and efficacy of a novel mattress technology-the Sound-To-Sleep (STS) system-in the treatment of sleep problems in children with autism. After screening, 45 children, ages 2.5 to 12.9 years, were randomized to order of mattress technology use (On-Off vs. Off-On). Treatment conditions (On vs. Off) lasted two weeks with immediate crossover. Tolerability, including study discontinuation and parent-report of mattress tolerance and ease of use, was tracked throughout the study. Efficacy assessments were obtained at baseline, prior to crossover, and end of study and included measures of autism traits, other psychopathology symptoms, sensory abnormalities, communication difficulties, quality of life, sleep diary parameters, and single-blinded actigraphy-derived sleep parameters. Statistical analyses evaluated differences in tolerability and efficacy when the STS system was on versus off. STS system use was well tolerated (n = 2, 4.4% dropout) and resulted in parent-reported sleep quality improvements (STS off mean = 4.3, 95% CI = 4.05-4.54 vs. on mean = 4.9, 95%CI = 4.67-5.14). The technology was described by parents as very easy to use and child tolerance was rated as good. Parent-diary outcomes indicated improvements in falling asleep and reduced daytime challenging behavior. Actigraphy-derived sleep parameters indicated improved sleep duration and sleep efficiency. Improvements in child and family quality of life were identified on parent questionnaires. A future large sample phase 2 trial of the STS system is warranted and would benefit from extended study duration, an objective primary efficacy outcome, and careful attention to methodological issues that promote compliance with the intervention and study procedures. © 2017 American Academy of Sleep Medicine

  20. Safe Handling and Use of Flammable and Combustible Materials. Module SH-30. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on safe handling and use of flammable and combustible materials is one of 50 modules concerned with job safety and health. This module introduces the student to the hazards of flammable and combustible materials and the measures necessary to control those hazards. Following the introduction, 14 objectives (each keyed to a page…

  1. The role of quantitative uncertainty in the safety analysis of flammable gas accidents in Hanford waste tanks

    International Nuclear Information System (INIS)

    Bratzel, D.R.

    1998-01-01

    Following a 1990 investigation into flammable gas generation, retention, and release mechanisms within the Hanford Site high-level waste tanks, personnel concluded that the existing Authorization Basis documentation did not adequately evaluate flammable gas hazards. The US Department of Energy Headquarters subsequently declared the flammable gas hazard as an unresolved safety issue. Although work scope has been focused on resolution of the issue, it has yet to be resolved due to considerable uncertainty regarding essential technical parameters and associated risk. Resolution of the Flammable Gas Safety Issue will include the identification of a set of controls for the Authorization Basis for the tanks which will require a safety analysis of flammable gas accidents. A traditional nuclear facility safety analysis is based primarily on the analysis of a set of bounding accidents to represent the risks of the possible accidents and hazardous conditions at a facility. While this approach may provide some indication of the bounding consequences of accidents for facilities, it does not provide a satisfactory basis for identification of facility risk or safety controls when there is considerable uncertainty associated with accident phenomena and/or data as is the case with potential flammable gas accidents at the Hanford Site. This is due to the difficulties in identifying the bounding case and reaching consensus among safety analysts, facility operations and engineering, and the regulator on the implications of the safety analysis results. In addition, the bounding cases are frequently based on simplifying assumptions that make the analysis results insensitive to variations among facilities or the impact of alternative safety control strategies. The existing safety analysis of flammable gas accidents for the Tank Waste Remediation system (TWRS) at the Hanford Site has these difficulties. However, Hanford Site personnel are developing a refined safety analysis approach

  2. Method for Predicting Hypergolic Mixture Flammability Limits

    Science.gov (United States)

    2017-02-01

    of all these phases. 15.  SUBJECT TERMS EOARD, rocket propulsion, combustion chemistry , energetic ionic liquids, flammability limits, fuel/oxidizer...Chemical Engineering Lab(UCP) This report is in support of the Integrated High Payoff Rocket Propulsion Technology (IHPRPT) Demonstration Program, which...formation at 298.15 K have been proposed by Osmont and co-workers [Osmont, 2007 and Osmont et al., 2007] by using quantum chemistry computations at

  3. Chemical Safety Alert: Lightning Hazard to Facilities Handling Flammable Substances

    Science.gov (United States)

    Raises awareness about lightning strikes, which cause more death/injury and damage than all other environmental elements combined, so industry can take proper precautions to protect equipment and storage or process vessels containing flammable materials.

  4. Strategy for resolution of the Flammable Gas Safety Issue

    International Nuclear Information System (INIS)

    Johnson, G.D.

    1995-01-01

    The purpose of this document is to provide the general strategy for resolution of the flammable gas safety issue; it is not a detailed description of program activities. budgets and schedules. Details of the program activities have been issued (Johnson and Sherwood, 1994) and the information pertaining to budgets is provided in the FY 1995-1997 Multi-Year Work Plan for Tank Waste Remediation System (TWRS) (Program Element 1.1.1.2.02.). The key element in this strategy is to provide an understanding of the behavior of each of the Flammable Gas Watch List tanks. While a review of historical information does provide some insight, it is necessary to gather current information about the gases, behavior and nature of the waste,. and about the control systems that maintain and monitor the waste. Analysis of this information will enable TWRS to determine the best approach to place any tank in a safe condition, if it is found to be in an unsafe state

  5. Safety basis for selected activities in single-shell tanks with flammable gas concerns. Revision 1

    International Nuclear Information System (INIS)

    Schlosser, R.L.

    1996-01-01

    This is full revision to Revision 0 of this report. The purpose of this report is to provide a summary of analyses done to support activities performed for single-shell tanks. These activities are encompassed by the flammable gas Unreviewed Safety Question (USQ). The basic controls required to perform these activities involve the identification, elimination and/or control of ignition sources and monitoring for flammable gases. Controls are implemented through the Interim Safety Basis (ISB), IOSRs, and OSDs. Since this report only provides a historical compendium of issues and activities, it is not to be used as a basis to perform USQ screenings and evaluations. Furthermore, these analyses and others in process will be used as the basis for developing the Flammable Gas Topical Report for the ISB Upgrade

  6. Slurry growth, gas retention, and flammable gas generation by Hanford radioactive waste tanks: Synthetic waste studies, FY 1991

    International Nuclear Information System (INIS)

    Bryan, S.A.; Pederson, L.R.; Ryan, J.L.; Scheele, R.D.; Tingey, J.M.

    1992-08-01

    Of 177 high-level waste storage tanks on the Hanford Site, 23 have been placed on a safety watch list because they are suspected of producing flammable gases in flammable or explosive concentrate. One tankin particular, Tank 241-SY-101 (Tank 101-SY), has exhibited slow increases in waste volume followed by a rapid decrease accompanied by venting of large quantities of gases. The purpose of this study is to help determine the processes by which flammable gases are produced, retained, and eventually released from Tank 101-SY. Waste composition data for single- and double-shell waste tanks on the flammable gas watch listare critically reviewed. The results of laboratory studies using synthetic double-shell wastes are summarized, including physical and chemical properties of crusts that are formed, the stoichiometry and rate ofgas generation, and mechanisms responsible for formation of a floating crust

  7. Assessing and ranking the flammability of some ornamental plant species to select firewise plants for landscaping in WUI (SE France).

    Science.gov (United States)

    Ganteaume, A.; Jappiot, M.; Lampin, C.

    2012-04-01

    The increasing urbanization of Wildland-Urban Interfaces (WUI) as well as the high fire occurrence in these areas requires the assessment and the ranking of the flammability of the ornamental vegetation surrounding houses especially that planted in hedges. Thus, the flammability of seven species, among those most frequently planted in hedges in Provence (South-Eastern France), were studied at particle level and at dead surface fuel level (litters) under laboratory conditions. The flammability parameters (ignition frequency, time-to-ignition, flaming duration) of the very fine particles (live leaves and particles fire bench. Burning experiments using the epiradiator showed that live leaves of Phyllostachys sp., Photinia frasei and Prunus laurocerasus had the shortest time-to-ignition and the highest ignition frequency and flaming duration whereas Pittosporum tobira and Nerium oleander were the longest to ignite with a low frequency. Phyllostachys sp. and Nerium oleander litters were the shortest to ignite while Prunus laurocerasus litter had the lowest bulk density and long time-to-ignition, but high flame propagation. Photinia fraseri litter ignited frequently and had a high flame spread while Pittosporum tobira litter ignited the least frequently and for the shortest duration. Cupressus sempervirens litter had the highest bulk density and the longest flaming duration but the lowest flame propagation. Pyracantha coccinea litter was the longest to ignite and flame propagation was low but lasted a long time. Hierarchical cluster analysis performed on the flammability parameters of live leaves and of litters ranked the seven species in four distinct clusters from the most flammable (Prunus laurocerasus and Pyracantha coccinea) to the least flammable (Pittosporum tobira and Nerium oleander); the other species displaying two groups of intermediate flammabilities (Phyllostachys sp.- Photinia fraseri and Cupressus sempervirens ). The species with highly flammable

  8. Methods of Off-Gas Flammability Control for DWPF Melter Off-Gas System at Savannah River Site

    International Nuclear Information System (INIS)

    Choi, A.S.; Iverson, D.C.

    1996-01-01

    Several key operating variables affecting off-gas flammability in a slurry-fed radioactive waste glass melter are discussed, and the methods used to prevent potential off-gas flammability are presented. Two models have played a central role in developing such methods. The first model attempts to describe the chemical events occurring during the calcining and melting steps using a multistage thermodynamic equilibrium approach, and it calculates the compositions of glass and calcine gases. Volatile feed components and calcine gases are fed to the second model which then predicts the process dynamics of the entire melter off-gas system including off-gas flammability under both steady state and various transient operating conditions. Results of recent simulation runs are also compared with available data

  9. Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients’ temperatures in prehospital emergency care – an intervention study

    Directory of Open Access Journals (Sweden)

    Jonas Aléx

    2015-09-01

    Full Text Available Background: The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients’ exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients’ temperatures in the prehospital emergency care. Methods: A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30 was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30 no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS, subjective comments on cold experiences, and finger, ear and air temperatures. Results: Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001 but decreased in the control group (p=0.014. A significant higher proportion (57% of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, p<0.001. At arrival, finger, ear and compartment air temperature showed no statistical significant difference between groups. Mean transport time was approximately 15 minutes. Conclusions: The use of active heat from underneath increases the patients’ thermal comfort and may prevent the negative consequences of cold stress.

  10. 75 FR 51020 - Third Party Testing for Certain Children's Products; Mattresses, Mattress Pads, and/or Mattress...

    Science.gov (United States)

    2010-08-18

    ... Standardization (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... body that was ISO/IEC 17025 accredited by an ILAC-MRA member at the time of the test. For firewalled...

  11. Fixed target flammable gas upgrades

    International Nuclear Information System (INIS)

    Schmitt, R.; Squires, B.; Gasteyer, T.; Richardson, R.

    1996-12-01

    In the past, fixed target flammable gas systems were not supported in an organized fashion. The Research Division, Mechanical Support Department began to support these gas systems for the 1995 run. This technical memo describes the new approach being used to supply chamber gasses to fixed target experiments at Fermilab. It describes the engineering design features, system safety, system documentation and performance results. Gas mixtures provide the medium for electron detection in proportional and drift chambers. Usually a mixture of a noble gas and a polyatomic quenching gas is used. Sometimes a small amount of electronegative gas is added as well. The mixture required is a function of the specific chamber design, including working voltage, gain requirements, high rate capability, aging and others. For the 1995 fixed target run all the experiments requested once through gas systems. We obtained a summary of problems from the 1990 fixed target run and made a summary of the operations logbook entries from the 1991 run. These summaries primarily include problems involving flammable gas alarms, but also include incidents where Operations was involved or informed. Usually contamination issues were dealt with by the experimenters. The summaries are attached. We discussed past operational issues with the experimenters involved. There were numerous incidents of drift chamber failure where contaminated gas was suspect. However analyses of the gas at the time usually did not show any particular problems. This could have been because the analysis did not look for the troublesome component, the contaminant was concentrated in the gas over the liquid and vented before the sample was taken, or that contaminants were drawn into the chambers directly through leaks or sub-atmospheric pressures. After some study we were unable to determine specific causes of past contamination problems, although in argon-ethane systems the problems were due to the ethane only

  12. Potential Flammable Gas Explosion in the TRU Vent and Purge Machine

    International Nuclear Information System (INIS)

    Vincent, A

    2006-01-01

    The objective of the analysis was to determine the failure of the Vent and Purge (V and P) Machine due to potential explosion in the Transuranic (TRU) drum during its venting and/or subsequent explosion in the V and P machine from the flammable gases (e.g., hydrogen and Volatile Organic Compounds [VOCs]) vented into the V and P machine from the TRU drum. The analysis considers: (a) increase in the pressure in the V and P cabinet from the original deflagration in the TRU drum including lid ejection, (b) pressure wave impact from TRU drum failure, and (c) secondary burns or deflagrations resulting from excess, unburned gases in the cabinet area. A variety of cases were considered that maximized the pressure produced in the V and P cabinet. Also, cases were analyzed that maximized the shock wave pressure in the cabinet from TRU drum failure. The calculations were performed for various initial drum pressures (e.g., 1.5 and 6 psig) for 55 gallon TRU drum. The calculated peak cabinet pressures ranged from 16 psig to 50 psig for various flammable gas compositions. The blast on top of cabinet and in outlet duct ranged from 50 psig to 63 psig and 12 psig to 16 psig, respectively, for various flammable gas compositions. The failure pressures of the cabinet and the ducts calculated by structural analysis were higher than the pressure calculated from potential flammable gas deflagrations, thus, assuring that V and P cabinet would not fail during this event. National Fire Protection Association (NFPA) 68 calculations showed that for a failure pressure of 20 psig, the available vent area in the V and P cabinet is 1.7 to 2.6 times the required vent area depending on whether hydrogen or VOCs burn in the V and P cabinet. This analysis methodology could be used to design the process equipment needed for venting TRU waste containers at other sites across the Department of Energy (DOE) Complex

  13. Cycling performance of lithium polymer cells assembled by in situ polymerization of a non-flammable ionic liquid monomer

    International Nuclear Information System (INIS)

    Lee, Yoon-Sung; Kim, Dong-Won

    2013-01-01

    Highlights: • Gel polymer electrolytes were synthesized by in situ polymerization of ionic liquid in the lithium polymer cells. • Flammability of the electrolyte was significantly reduced by polymerizing electrolyte containing a non-flammable ionic liquid monomer. • The cells assembled with polymeric ionic liquid-based electrolytes exhibited reversible cycling behavior with good capacity retention. -- Abstract: Lithium polymer cells composed of a lithium negative electrode and a LiCoO 2 positive electrode were assembled with a gel polymer electrolyte obtained by in situ polymerization of an electrolyte solution containing an ionic liquid monomer with vinyl groups. The polymerization of the electrolyte solution containing the non-flammable ionic liquid monomer resulted in a significant reduction of the flammability of the gel polymer electrolytes. The lithium polymer cell assembled with the stable gel polymer electrolyte delivered a discharge capacity of 134.3 mAh g −1 at ambient temperature and exhibited good capacity retention

  14. Spreaders, igniters, and burning shrubs: plant flammability explains novel fire dynamics in grass-invaded deserts.

    Science.gov (United States)

    Fuentes-Ramirez, Andres; Veldman, Joseph W; Holzapfel, Claus; Moloney, Kirk A

    2016-10-01

    Novel fire regimes are an important cause and consequence of global environmental change that involve interactions among biotic, climatic, and human components of ecosystems. Plant flammability is key to these interactions, yet few studies directly measure flammability or consider how multiple species with different flammabilities interact to produce novel fire regimes. Deserts of the southwestern United States are an ideal system for exploring how novel fire regimes can emerge when fire-promoting species invade ecosystems comprised of species that did not evolve with fire. In these deserts, exotic annual grasses provide fuel continuity across landscapes that did not historically burn. These fires often ignite a keystone desert shrub, the fire-intolerant creosote bush, Larrea tridentata (DC.) Coville. Ignition of Larrea is likely catalyzed by fuels produced by native plants that grow beneath the shrubs. We hypothesize that invasive and native species exhibit distinct flammability characteristics that in combination determine spatial patterns of fire spread and intensity. We measured flammability metrics of Larrea, two invasive grasses, Schismus arabicus and Bromus madritensis, and two native plants, the sub-shrub Ambrosia dumosa and the annual herb Amsinckia menziesii. Results of laboratory experiments show that the grasses carry fire quickly (1.32 cm/s), but burn for short duration (0.5 min) at low temperatures. In contrast, native plants spread fire slowly (0.12 cm/s), but burn up to eight times longer (4 min) and produced hotter fires. Additional experiments on the ignition requirements of Larrea suggest that native plants burn with sufficient temperature and duration to ignite dead Larrea branches (time to ignition, 2 min; temperature at ignition 692°C). Once burning, these dead branches ignite living branches in the upper portions of the shrub. Our study provides support for a conceptual model in which exotic grasses are "spreaders" of fire and native

  15. Comparison and evaluation of methods for the determination of flammability limits, applied to methane/hydrogen/air mixtures

    International Nuclear Information System (INIS)

    Schoor, F. van den; Hermanns, R.T.E.; Oijen, J.A. van; Verplaetsen, F.; Goey, L.P.H. de

    2008-01-01

    Different methods, both experimental and numerical, to determine the flammability limits are compared and evaluated, exemplified by a determination of the flammability limits of methane/hydrogen/air mixtures for hydrogen fuel molar fractions of 0, 0.2, 0.4 and 0.6, at atmospheric pressure and ambient temperature. Two different experimental methods are used. The first method uses a glass tube with visual observation of the flame, whereas the second method uses a closed spherical vessel with a pressure rise criterion to determine whether flame propagation has occurred. In addition to these experiments, the flammability limits are determined numerically. Unsteady planar and spherically expanding flames are calculated with a one-dimensional flame code with the inclusion of radiation heat loss in the optically thin limit. Comparison of the experimental results with the results of the planar flame calculations shows large differences, especially for lean mixtures. These differences increase with increasing hydrogen content in the fuel. Better agreement with the experimental results is found for the spherically expanding flame calculations. A limiting burning velocity of 5 cm/s is found to predict the upper flammability limit determined with the tube method very well, whereas the limiting flame temperature approach was found to give poorer agreement. Further analysis indicates that the neglect of flame front instabilities is the probable cause of the large differences between experimental and numerical results at the lower flammability limit

  16. Non-Toxic, Non-Flammable, -80 C Phase Change Materials

    Science.gov (United States)

    Cutbirth, J. Michael

    2013-01-01

    The objective of this effort was to develop a non-toxic, non-flammable, -80 C phase change material (PCM) to be used in NASA's ICEPAC capsules for biological sample preservation in flight to and from Earth orbit. A temperature of about -68 C or lower is a critical temperature for maintaining stable cell, tissue, and cell fragment storage.

  17. Non-Flammable Crew Clothing Utilizing Phosphorus-Based Fire Retardant Polymers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — For maintaining U.S. leadership role in space exploration, there is an urgent need to develop non-flammable shirts, shorts, sweaters, and jackets without...

  18. Control Decisions for Flammable Gas Hazards in Double Contained Receiver Tanks (DCRTs)

    Energy Technology Data Exchange (ETDEWEB)

    KRIPPS, L.J.

    2000-06-28

    This report describes the control decisions for flammable gas hazards in double-contained receiver tanks (DCRTs) made at control decision meetings on November 16, 17, and 18, 1999, on April 19,2000, and on May 10,2000, and their basis. These control decisions, and the analyses that support them, will be documented in an amendment to the Final Safety Analysis Report (FSAR) (CHG 2000a) and Technical Safety Requirements (TSR) (CHG 2000b) to close the Flammable Gas Unreviewed Safety Question (USQ) (Bacon 1996 and Wagoner 1996) for DCRTs. Following the contractor Tier I review of the FSAR and TSR amendment, it will be submitted to the U.S. Department of Energy (DOE), Office of River Protection (ORP) for review and approval.

  19. Data Observations on Double Shell Tank (DST) Flammable Gas Watch List Tank Behavior

    Energy Technology Data Exchange (ETDEWEB)

    HEDENGREN, D.C.

    2000-09-28

    This report provides the data from the retained gas sampler, void fraction instrument, ball rheometer, standard hydrogen monitoring system, and other tank data pertinent to gas retention and release behavior in the waste stored in double-shelled Flammable Gas Watch List tanks at Hanford. These include tanks 241-AN-103,241-AN-104, 241-AN-105, 241-AW-101, 241-SY-101, and 241-SY-103. The tanks and the waste they contain are described in terms of fill history and chemistry. The results of mixer pump operation and recent waste transfers and back-dilution in SY-101 are also described. In-situ measurement and monitoring systems are described and the data are summarized under the categories of thermal behavior, waste configuration and properties, gas generation and composition, gas retention and historical gas release behavior.

  20. Action plan for response to abnormal conditions in Hanford high level radioactive liquid waste storage tanks containing flammable gases

    International Nuclear Information System (INIS)

    Sherwood, D.J.

    1994-03-01

    Radioactive liquid waste tends to produce hydrogen as a result of the interaction of gamma radiation and water. In tanks containing organic chelating agents, additional hydrogen gas as well as nitrous oxide and ammonia can be produced by thermal and radiolytic decomposition of these organics. Several high-level radioactive liquid waste storage tanks, located underground at the Hanford Site, contain waste that retains the gases produced in them until large quantities are released rapidly to the tank vapor space. Tanks filled to near capacity have relatively little vapor space; therefore, if the waste suddenly releases a large amount of hydrogen and nitrous oxide, a flammable gas mixture may result. The most notable waste tank with a flammable gas problem is tank 241-SY-101. Waste in this tank has occasionally released enough flammable gas to burn if an ignition source had been present inside of the tank. Several other waste tanks exhibit similar behavior to a lesser magnitude. Administrative controls have been developed to assure that these Flammable Gas Watch List tanks are safely maintained. Responses have also been developed for off-normal conditions which might develop in these tanks. In addition, scientific and engineering studies are underway to further understand and mitigate the behavior of the Flammable Gas Watch List tanks

  1. Low-Flammability PTFE for High-Oxygen Environments

    Science.gov (United States)

    Walle, E.; Fallon, B.; Sheppard, A.

    1986-01-01

    Modified forming process removes volatile combustible materials. Flammability of cable-wrapping tape reduced by altering tape-manufacturing process. In new manufacturing process, tape formed by proprietary process of screw extrusion, followed by washing in solvent and drying. Tape then wrapped as before. Spectrogram taken after extrusion, washing, and drying shows lower hydrocarbon content. PTFE formed by new process suited to oxygen-rich environments. Safe in liquid oxygen of Space Shuttle tank and in medical uses; thin-wall shrinkable tubing in hospital test equipment, surgical instruments, and implants.

  2. The Efficiency of Non-Flammable Functional Underwear

    Directory of Open Access Journals (Sweden)

    Glombikova Viera

    2014-09-01

    Full Text Available This study evaluates the efficiency of non-flammable functional underwear used as a secondary heat barrier in extreme conditions. Five groups of knitted fabrics were analysed for flame resistance and selected physiological properties (water vapour permeability, air permeability, thermal resistance and liquid moisture transport by moisture management transport. The results indicated similar levels of flame resistance for the materials tested but show important differences in terms of physiological characteristics, namely liquid moisture transport, which influences the safety and comfort of protective clothing.

  3. Flammability characteristics of combustible gases and vapors

    Energy Technology Data Exchange (ETDEWEB)

    Zabetakis, M. G. [Bureau of Mines, Pittsburgh, PA (United States)

    1964-05-01

    This is a summary of the available limit of flammability, autoignition and burning-rate data for more than 200 combustible gases and vapors in air and other oxidants, as well as of empirical rules and graphs that can be used to predict similar data for thousands of other combustibles under a variety of environmental conditions. Spec$c data are presented on the paraffinic, unsaturated, aromatic, and alicyclic hydrocarbons, alcohols, ethers, aldehydes, ketones, and sulfur compounds, and an assortment of fuels, fuel blends, hydraulic fluids, engine oils, and miscellaneous combustible gases and vapors.

  4. A preliminary study on the thermal conductivity and flammability of WPC based on some tropical woods

    International Nuclear Information System (INIS)

    Chia, L.H.L.; Chua, P.H.; Lee, E.E.N.

    1985-01-01

    Selected local woods and their wood-polymer combinations or composites (WPC) were tested for their thermal conductivity and their fire resistance. WPC were prepared by polymerizing monomers 'in situ' in oven dried woods by gamma radiation. The monomers included acrylonitrile (AN), 60% styrene-40% acrylonitrile (STAN), methyl methacrylate (MMA), 95% methyl methacrylate-5% dioxane (MD), and vinylidene chloride (VDC). A reduction in thermal conductivity was exhibited by all the composites prepared. W-PAN showed the greatest reduction in thermal conductivity and W-PSTAN in general showed the least. An explanation is suggested for this behaviour. The polymers PMMA and PMD were found to enhance flammability of the woods while PVDC, PAN, and PSTAN imparted fire resistance to the woods. Of the six local woods studied, Ramin-and-Keruing-polymer composites showed the highest flammable tendencies obtained. The correlation of thermal conductivity to flammability is discussed. (author)

  5. Reference Material Kydex(registered trademark)-100 Test Data Message for Flammability Testing

    Science.gov (United States)

    Engel, Carl D.; Richardson, Erin; Davis, Eddie

    2003-01-01

    The Marshall Space Flight Center (MSFC) Materials and Processes Technical Information System (MAPTIS) database contains, as an engineering resource, a large amount of material test data carefully obtained and recorded over a number of years. Flammability test data obtained using Test 1 of NASA-STD-6001 is a significant component of this database. NASA-STD-6001 recommends that Kydex 100 be used as a reference material for testing certification and for comparison between test facilities in the round-robin certification testing that occurs every 2 years. As a result of these regular activities, a large volume of test data is recorded within the MAPTIS database. The activity described in this technical report was undertaken to mine the database, recover flammability (Test 1) Kydex 100 data, and review the lessons learned from analysis of these data.

  6. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.

    Science.gov (United States)

    Bhatia, Sanjeev; Civitarese, David M; Turnbull, Travis Lee; LaPrade, Christopher M; Nitri, Marco; Wijdicks, Coen A; LaPrade, Robert F

    2016-03-01

    Complete radial tears of the medial meniscus have been reported to be functionally similar to a total meniscectomy. At present, there is no consensus on an ideal technique for repair of radial midbody tears of the medial meniscus. Prior attempts at repair with double horizontal mattress suture techniques have led to a reportedly high rate of incomplete healing or healing in a nonanatomic (gapped) position, which compromises the ability of the meniscus to withstand hoop stresses. A newly proposed 2-tunnel radial meniscal repair method will result in decreased gapping and increased ultimate failure loads compared with the double horizontal mattress suture repair technique under cyclic loading. Controlled laboratory study. Ten matched pairs of male human cadaveric knees (average age, 58.6 years; range, 48-66 years) were used. A complete radial medial meniscal tear was made at the junction of the posterior one-third and middle third of the meniscus. One knee underwent a horizontal mattress inside-out repair, while the contralateral knee underwent a radial meniscal repair entailing the same technique with a concurrent novel 2-tunnel repair. Specimens were potted and mounted on a universal testing machine. Each specimen was cyclically loaded 1000 times with loads between 5 and 20 N before experiencing a load to failure. Gap distances at the tear site and failure load were measured. The 2-tunnel repairs exhibited a significantly stronger ultimate failure load (median, 196 N; range, 163-212 N) than did the double horizontal mattress suture repairs (median, 106 N; range, 63-229 N) (P = .004). In addition, the 2-tunnel repairs demonstrated decreased gapping at all testing states (P meniscus significantly decrease the ability of the meniscus to dissipate tibiofemoral loads, predisposing patients to early osteoarthritis. Improving the ability to repair medial meniscal radial tears in a way that withstands cyclic loads and heals in an anatomic position could significantly

  7. Flammability of polypropylene/organoclay nanocomposites

    International Nuclear Information System (INIS)

    Alves, Tatianny Soares; Barbosa, Renata; Carvalho, Laura Hecker de; Canedo, Eduardo Luis

    2014-01-01

    The flammabilities of nanocomposites made with three polypropylene grades (homo and copolymers) with 5 wt % of organoclay (Cloisite 20A), 5 or 15 wt % of maleated polypropylene as compatibilizer, and 0, 0.5 or 1 wt % of cis-13-docosenamide (Erucamide) as co-intercalant, were studied using the horizontal burning test UL94HB. Masterbatches prepared in an internal mixer were diluted in the polypropylene matrix using a corotating twin-screw extruder, with different screw configurations and operating at 240 or 480 rpm. Results indicate that the high burning rate of the composites was not affected by the processing conditions. For all formulations was observed a significant reduction in smoke release, lack of dripping and the formation of a char surface layer, that protected the core of the samples. (author)

  8. Responding to Terrorist Incidents in Your Community: Flammable-Liquid Fire Fighting Techniques for Municipal and Rural Firefighters

    Energy Technology Data Exchange (ETDEWEB)

    Denise Baclawski

    2010-03-08

    The University of Nevada, Reno Fire Science Academy (FSA) applied for grant funding to develop and deliver programs for municipal, rural, and volunteer firefighters. The FSA specializes in preparing responders for a variety of emergency events, including flammable liquid fires resulting from accidents, intentional acts, or natural disasters. Live fire training on full scale burnable props is the hallmark of FSA training, allowing responders to practice critical skills in a realistic, yet safe environment. Unfortunately, flammable liquid live fire training is often not accessible to municipal, rural, or volunteer firefighters due to limited department training budgets, even though most department personnel will be exposed to flammable liquid fire incidents during the course of their careers. In response to this training need, the FSA developed a course during the first year of the grant (Year One), Responding to Terrorist Incidents in Your Community: Flammable-Liquid Fire Fighting Techniques for Municipal and Rural Firefighters. During the three years of the grant, a total of 2,029 emergency responders received this training. In Year Three, two new courses, a train-the-trainer for Responding to Terrorist Incidents in Your Community and Management of Large-Scale Disasters for Public Officials were developed and pilot tested during the Real-World Disaster Management Conference held at the FSA in June of 2007. Two research projects were conducted during Years Two and Three. The first, conducted over a two year period, evaluated student surveys regarding the value of the flammable liquids training received. The second was a needs assessment conducted for rural Nevada. Both projects provided important feedback and a basis for curricula development and improvements.

  9. 29 CFR 1910.107 - Spray finishing using flammable and combustible materials.

    Science.gov (United States)

    2010-07-01

    ... drying apparatus and electrical connections and wiring thereto shall not be located within spray... apparatus, the drying apparatus, and the ventilating system of the spray enclosure shall be equipped with... 29 Labor 5 2010-07-01 2010-07-01 false Spray finishing using flammable and combustible materials...

  10. Flammability and thermal properties studies of nonwoven flax reinforced acrylic based polyester composites

    Science.gov (United States)

    Rasyid, M. F. Ahmad; Salim, M. S.; Akil, H. M.; Ishak, Z. A. Mohd.

    2017-12-01

    In the pursuit of green and more sustainable product, natural fibre reinforced composites originating from renewable resources has gained interest in recent years. These natural fibres exhibit good mechanical properties, low production costs, and good environmental properties. However, one of the disadvantages of natural fibre reinforced composites is their high flammability that limits their application in many fields. Within this research, the effect of sodium silicate on the flammability and thermal properties of flax reinforced acrylic based polyester composites has been investigated. Sodium silicate is applied as binder and flame retardant system in impregnation process of the natural flax fiber mats. The addition of sodium silicate significantly improved the flame retardant efficiency but reduced the degree of crosslinking of the composites.

  11. LBA-ECO LC-02 Forest Flammability Data, Catuaba Experimental Farm, Acre, Brazil: 1998

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides the results of controlled burns conducted to assess the flammability of mature forests on the Catuaba Experimental Farm of the Federal...

  12. LBA-ECO LC-02 Forest Flammability Data, Catuaba Experimental Farm, Acre, Brazil: 1998

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set provides the results of controlled burns conducted to assess the flammability of mature forests on the Catuaba Experimental Farm of the...

  13. Fleet Composition of Rail Tank Cars That Transport Flammable Liquids: 2013-2016

    Science.gov (United States)

    2017-09-05

    Section 7308 of the Fixing America's Surface Transportation Act (FAST Act; P. L. 114-94; December 4, 2015) requires the U.S. Department of Transportation (DOT) to assemble and collect data on rail tank cars transporting Class 3 flammable liquids (box...

  14. Development of Large-Format Lithium-Ion Cells with Silicon Anode and Low Flammable Electrolyte

    Science.gov (United States)

    Wu, James J.; Hernandez-Lugo, D. M.; Smart, M. C.; Ratnakumar, B. V.; Miller, T. B.; Lvovich, V. F.; Lytle, J. K.

    2014-01-01

    NASA is developing safe, high energy and high capacity lithium-ion cell designs and batteries for future missions under NASAs Advanced Space Power System (ASPS) project. Advanced cell components, such as high specific capacity silicon anodes and low-flammable electrolytes have been developed for improving the cell specific energy and enhancing safety. To advance the technology readiness level, we have developed large-format flight-type hermetically sealed battery cells by incorporating high capacity silicon anodes, commercially available lithium nickel, cobalt, aluminum oxide (NCA) cathodes, and low-flammable electrolytes. In this report, we will present the performance results of these various battery cells. In addition, we will also discuss the post-test cell analysis results as well.

  15. 77 FR 73354 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2012-12-10

    .... Edwards, Project Manager, Directorate for Engineering Sciences, U.S. Consumer Product Safety Commission, 5..., allergic reactions and near- choking episodes are the most common injuries reported in the remaining 58... modification of the ASTM standard to address the requirements for flammability, surface chemicals, cords...

  16. Retained Gas Sampling Results for the Flammable Gas Program

    International Nuclear Information System (INIS)

    Bates, J.M.; Mahoney, L.A.; Dahl, M.E.; Antoniak, Z.I.

    1999-01-01

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples

  17. Retained Gas Sampling Results for the Flammable Gas Program

    Energy Technology Data Exchange (ETDEWEB)

    J.M. Bates; L.A. Mahoney; M.E. Dahl; Z.I. Antoniak

    1999-11-18

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples.

  18. The selection of skin care products for use in hyperbaric chamber may depend on flammability acceptability indices score.

    Science.gov (United States)

    McCord, Darlene E; Newton, Barry E; Fore, Jane; Chiffoleau, Gwenael

    2008-02-01

    Current protocols call for stopping adjunctive skin care treatments during hyperbaric oxygen therapy (HBOT) because the hyperbaric environment is considered unsafe for skin care products. The elevated oxygen fraction and the increased pressure in the hyperbaric chamber dramatically increase the flammability potential of materials, leading to the need for rigorous standards to prevent flame ignition. A scientific method of evaluating the flammability risks associated with skin care products would be helpful. Several skin care products were tested, using established industrial techniques for determining flammability potential with some modification. The information obtained from these tests can help clinicians make more rational decisions about which topical products can be used safely on patients undergoing HBOT. Wendell Hull & Associates conducted independent studies, comparing the oxygen compatibility for leading skin care products. Oxygen compatibility was determined using autogenous ignition temperature (AIT), oxygen index (OI), and heat of combustion (HoC) testing. AIT, a relative indication of a material's propensity for ignition, is the minimum temperature needed to cause a sample to self-ignite at a given pressure and oxygen concentration. OI, a relative indication of a material's flammability, is the minimum oxygen percentage that, when mixed with nitrogen, will sustain burning. HoC is the absolute value of a material's energy release when burning, if ignition occurs. Products with a high AIT, a high OI, and a low HoC are more compatible in an oxygen-enriched atmosphere (OEA). An acceptability index (AI) based on these 3 factors was calculated for the products, so the testers could rank overall material compatibility in OEAs (Lapin A. Oxygen Compatibility of Materials. International Institute of Refrigeration Commission Meeting; Brighton, England; 1973). Test results for the skin products varied widely. The AIT, OI, HoC, and AI were determined for each

  19. Flammability of self-extinguishing kenaf/ABS nanoclays composite for aircraft secondary structure

    Science.gov (United States)

    Karunakaran, S.; Majid, D. L.; Mohd Tawil, M. L.

    2016-10-01

    This study investigates the flammability properties of kenaf fiber reinforced acrylonitrile butadiene styrene (ABS) with nanoclays composites. Natural fiber is one of the potential materials to be used with thermoplastic as a composite due to its attractive properties such as lightweight and strong. In this paper, flammability properties of this material are evaluated through Underwriters Laboratory 94 Horizontal Burning (UL94 HB), which has been conducted for both controlled and uncontrolled conditions, smoke density and limiting oxygen index tests (LOI). These flammability tests are in compliance with the Federal Aviation Regulation (FAR) requirement. The results from UL94 HB and smoke density tests show that the presence of nanoclays with effective composition of kenaf fiber reinforced ABS has enhanced the burning characteristics of the material by hindering propagation of flame spread over the surface of the material through char formation. Consequently, this decreases the burning rate and produces low amount of smoke during burning. On contrary, through LOI test, this material requires less oxygen to burn when exposed to fire, which hinders the enhancement of burning characteristics. This is due to burning mechanism exhibited by nanoclays that catalyzes barrier formation and flame propagation rate over the surface of the biocomposite material. Overall, these experimental results suggest that this biocomposite material is capable of self-extinguishing and possesses effective fire extinction. The observed novel synergism from the result obtained is promising to be implemented in secondary structures of aircraft with significant benefits such as cost-effective, lightweight and biodegradable self-extinguishing biocomposite.

  20. Flammable gas safety program. Analytical methods development: FY 1994 progress report

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Wahl, K.; Steele, R.

    1994-09-01

    This report describes the status of developing analytical methods to account for the organic components in Hanford waste tanks, with particular focus on tanks assigned to the Flammable Gas Watch List. The methods that have been developed are illustrated by their application to samples obtained from Tank 241-SY-101 (Tank 101-SY)

  1. A refined safety analysis approach for closure of the Hanford Site flammable gas unreviewed safety question

    International Nuclear Information System (INIS)

    Bratzel, D.R.

    1997-01-01

    Following a 1990 investigation into flammable gas generation, retention, and release mechanisms within the Hanford Site high-level waste tanks, personnel concluded that the existing Authorization Basis documentation did not adequately evaluate flammable gas hazards. This declaration was based primarily on the fact that personnel did not adequately consider hydrogen and nitrous oxide evolution within the material in certain waste tanks and subsequent hypothetical ignition in the development of safety documentation for the waste tanks. The US Department of Energy-Headquarters subsequently declared an Unreviewed Safety Question (USQ). Although work scope has been focused on closure of the USQ since 1990, the DOE has yet to close the USQ because of considerable uncertainty regarding essential technical parameters and associated risk. The DOE recently approved a Basis for Interim Operation to revise the Authorization Basis for managing the tank farms, however, the USQ remains open. The two fundamental requirements for closure of the flammable gas USQ are as follows: development of a defensible technical basis for existing controls; development of a process to assess the adequacy of controls as the waste tank mission progresses

  2. Design review report for rotary mode core sample truck (RMCST) modifications for flammable gas tanks, preliminary design

    International Nuclear Information System (INIS)

    Corbett, J.E.

    1996-02-01

    This report documents the completion of a preliminary design review for the Rotary Mode Core Sample Truck (RMCST) modifications for flammable gas tanks. The RMCST modifications are intended to support core sampling operations in waste tanks requiring flammable gas controls. The objective of this review was to validate basic design assumptions and concepts to support a path forward leading to a final design. The conclusion reached by the review committee was that the design was acceptable and efforts should continue toward a final design review

  3. Flammability of Gas-Filled Polymers

    Directory of Open Access Journals (Sweden)

    Ushkov Valentin Anatol'evich

    2017-09-01

    Full Text Available The regularities of flame propagation on the horizontal surface of gas-filled polymers are considered depending on the concentration of oxygen in the oxidizer flow. The values of the coefficients in the expression describing relationship between the rate of flame propagation on the surface of foams and oxygen concentration are obtained. It was shown that with the mass content of reactive organophosphorus compounds reaching 4.0...5.9%, non-smoldering resole foam plastics with high performance characteristics are obtained. It was found that in order to obtain moderately combustible polyurethane foams based on oxyethylated phosphorus-containing polyols, the phosphorus concentration should not exceed 3 % of mass. To obtain flame-retardant urea-formaldehyde foam cellular plastics, the concentration of phosphorus should not exceed 0.3 % of mass. Physical-mechanical properties and flammability indices of developed gas-filled polymers based on reactive oligomers are presented.

  4. Fires in the Cenozoic: a late flowering of flammable ecosystems

    OpenAIRE

    Bond, William J.

    2015-01-01

    Modern flammable ecosystems include tropical and subtropical savannas, steppe grasslands, boreal forests, and temperate sclerophyll shrublands. Despite the apparent fiery nature of much contemporary vegetation, terrestrial fossil evidence would suggest we live in a time of low fire activity relative to the deep past. The inertinite content of coal, fossil charcoal, is strikingly low from the Eocene to the Pleistocene and no charcoalified mesofossils have been reported for the Cenozoic. Marine...

  5. Predicting the flammable region reach of propane vapor clouds

    OpenAIRE

    Vílchez Sánchez, Juan Antonio; Villafañe, Diana; Casal Fàbrega, Joaquim

    2014-01-01

    Liquified gas fuels are widely used around the world, and the growth of LNG and LPG consumption continues to increase. However, using these fuels can lead to accidents if they are released to the environment. Consequently, the challenge to control and predict such hazards has become an objective in emergency planning and risk analysis. In a previous article the “Dispersion Safety Factor” (DSF) was proposed, defined as the ratio between the distance at which the lower flammability limit concen...

  6. An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity & Extraterrestrial Fire-Safety Applications

    Science.gov (United States)

    Olson, S. L.; Beeson, H.; Haas, J.

    2001-01-01

    One of the performance goals for NASA's enterprise of Human Exploration and Development of Space (HEDS) is to develop methods, data bases, and validating tests for material flammability characterization, hazard reduction, and fire detection/suppression strategies for spacecraft and extraterrestrial habitats. This work addresses these needs by applying the fundamental knowledge gained from low stretch experiments to the development of a normal gravity low stretch material flammability test method. The concept of the apparatus being developed uses the low stretch geometry to simulate the conditions of the extraterrestrial environment through proper scaling of the sample dimensions to reduce the buoyant stretch in normal gravity. The apparatus uses controlled forced-air flow to augment the low stretch to levels which simulate Lunar or Martian gravity levels. In addition, the effect of imposed radiant heat flux on material flammability can be studied with the cone heater. After breadboard testing, the apparatus will be integrated into NASA's White Sands Test Facility's Atmosphere-Controlled Cone Calorimeter for evaluation as a new materials screening test method.

  7. Antero-posterior (AP) pelvis x-ray imaging on a trolley: Impact of trolley design, mattress design and radiographer practice on image quality and radiation dose

    International Nuclear Information System (INIS)

    Tugwell, J.R.; England, A.; Hogg, P.

    2017-01-01

    Introduction: Physical and technical differences exist between imaging on an x-ray tabletop and imaging on a trolley. This study evaluates how trolley imaging impacts image quality and radiation dose for an antero-posterior (AP) pelvis projection whilst subsequently exploring means of optimising this imaging examination. Methods: An anthropomorphic pelvis phantom was imaged on a commercially available trolley under various conditions. Variables explored included two mattresses, two image receptor holder positions, three source to image distances (SIDs) and four mAs values. Image quality was evaluated using relative visual grading analysis with the reference image acquired on the x-ray tabletop. Contrast to noise ratio (CNR) was calculated. Effective dose was established using Monte Carlo simulation. Optimisation scores were derived as a figure of merit by dividing effective dose with visual image quality scores. Results: Visual image quality reduced significantly (p < 0.05) whilst effective dose increased significantly (p < 0.05) for images acquired on the trolley using identical acquisition parameters to the reference image. The trolley image with the highest optimisation score was acquired using 130 cm SID, 20 mAs, the standard mattress and platform not elevated. A difference of 12.8 mm was found between the image with the lowest and highest magnification factor (18%). Conclusion: The acquisition parameters used for AP pelvis on the x-ray tabletop are not transferable to trolley imaging and should be modified accordingly to compensate for the differences that exist. Exposure charts should be developed for trolley imaging to ensure optimal image quality at lowest possible dose. - Highlights: • Acquisition parameters used for AP pelvis imaging on a trolley need adapting from those used on the x-ray tabletop. • Radiation dose significantly increases for trolley imaging. • An increase in SID can reduce radiation dose and magnification for trolley imaging

  8. Unmanned Vehicle Material Flammability Test

    Science.gov (United States)

    Urban, David; Ruff, Gary A.; Fernandez-Pello, A. Carlos; T’ien, James S.; Torero, Jose L.; Cowlard, Adam; Rouvreau, Sebastian; Minster, Olivier; Toth, Balazs; Legros, Guillaume; hide

    2013-01-01

    Microgravity combustion phenomena have been an active area of research for the past 3 decades however, there have been very few experiments directly studying spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample and environment sizes typical of those expected in a spacecraft fire. All previous experiments have been limited to samples of the order of 10 cm in length and width or smaller. Terrestrial fire safety standards for all other habitable volumes on earth, e.g. mines, buildings, airplanes, ships, etc., are based upon testing conducted with full-scale fires. Given the large differences between fire behavior in normal and reduced gravity, this lack of an experimental data base at relevant length scales forces spacecraft designers to base their designs using 1-g understanding. To address this question a large scale spacecraft fire experiment has been proposed by an international team of investigators. This poster presents the objectives, status and concept of this collaborative international project to examine spacecraft material flammability at realistic scales. The concept behind this project is to utilize an unmanned spacecraft such as Orbital Cygnus vehicle after it has completed its delivery of cargo to the ISS and it has begun its return journey to earth. This experiment will consist of a flame spread test involving a meter scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This will be

  9. 30 CFR 35.22 - Test to determine effect of evaporation on flammability.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test to determine effect of evaporation on... § 35.22 Test to determine effect of evaporation on flammability. (a) Purpose. The purpose of this test shall be to determine the effect of evaporation on the reduction of fire resistance of a hydraulic fluid...

  10. Operability test report for core sample truck number one flammable gas modifications

    International Nuclear Information System (INIS)

    Akers, J.C.

    1997-01-01

    This report primarily consists of the original test procedure used for the Operability Testing of the flammable gas modifications to Core Sample Truck No. One. Included are exceptions, resolutions, comments, and test results. This report consists of the original, completed, test procedure used for the Operability Testing of the flammable gas modifications to the Push Mode Core Sample Truck No. 1. Prior to the Acceptance/Operability test the truck No. 1 operations procedure (TO-080-503) was revised to be more consistent with the other core sample truck procedures and to include operational steps/instructions for the SR weather cover pressurization system. A draft copy of the operations procedure was used to perform the Operability Test Procedure (OTP). A Document Acceptance Review Form is included with this report (last page) indicating the draft status of the operations procedure during the OTP. During the OTP 11 test exceptions were encountered. Of these exceptions four were determined to affect Acceptance Criteria as listed in the OTP, Section 4.7 ACCEPTANCE CRITERIA

  11. Cost-effectiveness of pressure-relieving devices for the prevention and treatment of pressure ulcers.

    Science.gov (United States)

    Fleurence, Rachael L

    2005-01-01

    The cost-effectiveness of alternating pressure-relieving devices, mattress replacements, and mattress overlays compared with a standard hospital (high-specification foam mattress) for the prevention and treatment of pressure ulcers in hospital patients in the United Kingdom was investigated. A decision-analytic model was constructed to evaluate different strategies to prevent or treat pressure ulcers. Three scenarios were evaluated: the prevention of pressure ulcers, the treatment of superficial ulcers, and the treatment of severe ulcers. Epidemiological and effectiveness data were obtained from the clinical literature. Expert opinion using a rating scale technique was used to obtain quality of life data. Costs of the devices were obtained from manufacturers, whereas costs of treatment were obtained from the literature. Uncertainty was explored through probabilistic sensitivity analysis. Using 30,000 pounds sterling/QALY (quality-adjusted life year) as the decision-maker's cut off point (the current UK standard), in scenario 1 (prevention), the cost-effective strategy was the mattress overlay at 1, 4, and 12 weeks. In scenarios 2 and 3, the cost-effective strategy was the mattress replacement at 1, 4, and 12 weeks. Standard care was a dominated intervention in all scenarios for values of the decision-maker's ceiling ratio ranging from 5,000 pounds sterling to 100,000 pounds sterling/QALY. However, the probabilistic sensitivity analysis results reflected the high uncertainty surrounding the choice of devices. Current information suggests that alternating pressure mattress overlays may be cost-effective for the prevention of pressure ulcers, whereas alternating pressure mattress replacements appears to be cost-effective for the treatment of superficial and severe pressure ulcers.

  12. Effect of Environmental Variables on the Flammability of Fire Resistant Materials

    OpenAIRE

    Osorio, Andres Felipe

    2014-01-01

    This work investigates the effects of external radiation, ambient pressure and microgravity on the flammability limits of fire-resistant (FR) materials. Future space missions may require spacecraft cabin environments different than those used in the International Space Station, 21%O2, 101.3kPa. Environmental variables include flow velocity, oxygen concentration, ambient pressure, micro or partial-gravity, orientation, presence of an external radiant flux, etc. Fire-resistant materials are use...

  13. A Review of the Flammability Factors of Kenaf and Allied Fibre Reinforced Polymer Composites

    Directory of Open Access Journals (Sweden)

    C. H. Lee

    2014-01-01

    Full Text Available Natural fibre is a well-known reinforcement fibre in polymer-matrix Composites (PMC lately. Natural fibre has fast growing and abundance properties which make it available at very low cost. For kenaf fibre there is long lists of research projects which have been done regarding its behaviour, and properties and modification made to it. In this paper, fire flammability is the main concern for natural fibre reinforced polymer (NFRP composites especially kenaf fibre. To estimate its flammability, a wide range of factors can be considered such as fibre content, type of matrices, pH conditions, treatment, and fire retardant (FR filler’s type. The most important criteria are the ignition time, rate of propagation, and fire behavior. thermogravimetric analysis (TGA, different scanning calorimetric (DSC, and dynamic mechanical analysis (DMA are the three most famous methods used to investigate the fire behaviour of composites.

  14. Flammability of radiation cross-linked low density polyethylene as an insulating material for wire and cable

    International Nuclear Information System (INIS)

    Basfar, A.A.

    2002-01-01

    Various formulations of low-density polyethylene blended with ethylene vinyl acetate were prepared to improve the flame retardancy for wire and cable applications. The prepared formulations were cross-linked by γ-rays to 50, 100, 150 and 200 kGy in the presence of trimethylolpropane triacrylate (TMPTA). The effect of thermal aging on mechanical properties of these formulations were investigated. In addition, the influence of various combinations of aluminum trihydroxide and zinc borate as flame retardant fillers on the flammability was explored. Limiting oxygen index (LOI) and average extent of burning were used to characterize the flammability of investigated formulations. An improved flame retardancy of low density polyethylene was achieved by various combinations of flame ratardant fillers and cross-linking by gamma radiation

  15. Influence of natural or organophilic bentonite for flammable of the poly(ethylene-co-vinyl acetate)

    International Nuclear Information System (INIS)

    Heyder, Eduardo T.; Kloss, Juliana R.; Morita, Reinaldo Y.; Barbosa, Ronilson V.

    2015-01-01

    The manufacture polymeric applied in electrical sector in general use additives which act as flame retardants, for example, some borates, phosphates, and halogenated hydroxides. An alternative material for this purpose frequently reported in the literature because the flame resistance or flame retardancy is organoclay. Thus, the objective of this study is to evaluate the flammability of mixtures of EVA/natural bentonite and EVA/organoclay containing modifier as a species free of quaternary ammonium ions. The natural bentonite and organoclay were characterized by X-ray diffraction and scanning electron microscopy and materials were evaluated by X-ray diffraction and the flammability test. Regarding the combustion rate values, there was a reduction of flame propagation in EVA/natural bentonite (3.0%), showing that in this case the clay without modifier acted as a physical barrier and promoted retardant action of flame. (author)

  16. Development of a cost efficient methodology to perform allocation of flammable and toxic gas detectors applying CFD tools

    Energy Technology Data Exchange (ETDEWEB)

    Storch, Rafael Brod; Rocha, Gean Felipe Almeida [Det Norske Veritas (DNV), Rio de Janeiro, RJ (Brazil); Nalvarte, Gladys Augusta Zevallos [Det Norske Veritas (DNV), Novik (Norway)

    2012-07-01

    This paper is aimed to present a computational procedure for flammable and toxic gas detector allocation and quantification developed by DNV. The proposed methodology applies Computational Fluid Dynamics (CFD) simulations as well as operational and safety characteristics of the analyzed region to assess the optimal number of toxic and flammable gas detectors and their optimal location. A probabilistic approach is also used when applying the DNV software ThorEXPRESSLite, following NORSOK Z013 Annex G and presented in HUSER et al. 2000 and HUSER et al. 2001, when the flammable gas detectors are assessed. A DNV developed program, DetLoc, is used to run in an iterative way the procedure described above leading to an automatic calculation of the gas detectors location and number. The main advantage of the methodology presented above is the independence of human interaction in the gas detector allocation leading to a more precise and free of human judgment allocation. Thus, a reproducible allocation is generated when comparing several different analyses and a global criteria appliance is guaranteed through different regions in the same project. A case study is presented applying the proposed methodology. (author)

  17. System acceptance and operability test report for the RMCS exhauster C on flammable gas tanks

    International Nuclear Information System (INIS)

    Waldo, E.J.

    1998-01-01

    This test report documents the completion of acceptance and operability testing of the rotary mode core sampling (RMCS) exhauster C, as modified for use as a major stack (as defined by the Washington State Department of Health) on flammable gas tanks

  18. Experimental and numerical investigation of kerosene flammability

    Energy Technology Data Exchange (ETDEWEB)

    Sochet, I. [Orleans Univ., ENSIB, Lab. Energetique Explosions Structures, 18 - Bourges (France); Pascaud, J.M.; Gillard, P. [Orleans Univ., IUTde Bourges, Lab. Energetique Explosions Structures, 18 - Bourges (France)

    2002-08-01

    In an attempt to contribute to aircraft safety, it is fundamental to define the explosions conditions of kerosene vapor in an aircraft tank. Flammability properties of kerosene F-34 and F-35 have been determined experimentally. The flash point and the vapor pressure have been measured by means of an appropriate apparatus. A first analysis of the composition by GC-MS analysis shows four essential compounds: decane, dodecane, 1,2,4 trimethylbenzene and butyl-cyclohexane. The evolution of maximum pressure is compared with the theoretical values obtained with a simple model based on the theory of molecule collisions. A simple modelling has been developed as part of a novel study on ignition and combustion of classical propulsive powders and transposed to liquid kerosene droplets in order to predict the main characteristics of these explosions in a closed vessel. (authors)

  19. 16 CFR 1500.43a - Method of test for flashpoint of volatile flammable materials.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Method of test for flashpoint of volatile flammable materials. 1500.43a Section 1500.43a Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION... shall intersect the plane of the underside of the cover. The cover is also provided with an orifice...

  20. Design of a Novel Flexible Capacitive Sensing Mattress for Monitoring Sleeping Respiratory

    Directory of Open Access Journals (Sweden)

    Wen-Ying Chang

    2014-11-01

    Full Text Available In this paper, an algorithm to extract respiration signals using a flexible projected capacitive sensing mattress (FPCSM designed for personal health assessment is proposed. Unlike the interfaces of conventional measurement systems for poly-somnography (PSG and other alternative contemporary systems, the proposed FPCSM uses projected capacitive sensing capability that is not worn or attached to the body. The FPCSM is composed of a multi-electrode sensor array that can not only observe gestures and motion behaviors, but also enables the FPCSM to function as a respiration monitor during sleep using the proposed approach. To improve long-term monitoring when body movement is possible, the FPCSM enables the selection of data from the sensing array, and the FPCSM methodology selects the electrodes with the optimal signals after the application of a channel reduction algorithm that counts the reversals in the capacitive sensing signals as a quality indicator. The simple algorithm is implemented in the time domain. The FPCSM system is used in experimental tests and is simultaneously compared with a commercial PSG system for verification. Multiple synchronous measurements are performed from different locations of body contact, and parallel data sets are collected. The experimental comparison yields a correlation coefficient of 0.88 between FPCSM and PSG, demonstrating the feasibility of the system design.

  1. Flammable Gas Refined Safety Analysis Tool Software Verification and Validation Report for Resolve Version 2.5

    International Nuclear Information System (INIS)

    BRATZEL, D.R.

    2000-01-01

    The purpose of this report is to document all software verification and validation activities, results, and findings related to the development of Resolve Version 2.5 for the analysis of flammable gas accidents in Hanford Site waste tanks

  2. Redirecting fire-prone Mediterranean ecosystems toward more resilient and less flammable communities.

    Science.gov (United States)

    Santana, Victor M; Baeza, M Jaime; Valdecantos, Alejandro; Vallejo, V Ramón

    2018-06-01

    The extensive abandonment of agricultural lands in the Mediterranean basin has led to large landscapes being dominated by early-successional species, characterized by high flammability and an increasing fire risk. This fact promotes fire occurrence and places ecosystems in a state of arrested succession. In this work, we assessed the effectiveness of several restoration actions in redirecting these ecosystems toward more resilient communities dominated by resprouting species. These actions included the mechanical clearing of early-successional species, the plantation of resprouting species, and the combination of both treatments. For 13 years, we assessed shifts in the successional trajectory and ecosystem flammability by changes in: species composition, species richness, ecosystem evenness, the natural colonization of resprouting species, total biomass and proportion of dead biomass. We observed that the plantation and clearing combination was a suitable strategy to promote resilience. Species richness increased as well as the presence of the resprouting species introduced by planting. The natural colonization of the resprouting species was also enhanced. These changes in the successional trajectory were accompanied by a possible reduction of fire risk by reducing dead fuel proportion. These findings are relevant for the management of Mediterranean basin areas, but also suggest new tools for redirecting systems in fire-prone areas worldwide. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Clinical Results of Arthroscopic Repair of Isolated Longitudinal Tear of Medial Meniscus by Vertical Cruciate Double Mattress Sutures with Outside-in Technique

    Directory of Open Access Journals (Sweden)

    Seyied Hamid Barzgar

    2013-09-01

    Full Text Available Introduction : Meniscal tears are one of the most common injuries treated by arthroscopic techniques. Arthroscopic meniscal repair is an accepted way of treatment for meniscal tears. Different arthroscopic techniques for meniscal repair are: inside-out, outside-in and all inside. In the first 2 techniques, meniscus is repaired by sutures and in the later by suture or by commercial ready implants . The goal of current study is assessing clinical results of arthroscopic repair of longitudinal meniscal tears with vertical cruciate double mattress sutures by outside-in technique after 9 months.   Methods: In this case series study, in 13 patients having criteria for engaging the study with longitudinal isolated meniscus tear, arthroscopic meniscal repair was done with vertical cruciate double mattress sutures by outside-in technique and patients were followed for 9 months.   Results: Of 13 patients, there were 12 males (92.3% and one female (7.7% aged 15-38 (average 28.3 years. In follow up period, there was one case (7.7% of irritation by subcutaneous knot. There was not any failure of repair. Average Lysholm score increased from 55.23 to 91.23 after 9 months of follow up, which was statistically significant (p<0.001. At the end of follow up period, there was not any medial joint line tenderness of knee, giving way or significant effusion or pain.   Conclusion: This study shows that this technique has a good short term outcome with no failure and low complications but it is necessary to do more long term studies to prove it.

  4. Mechanical, Thermal Degradation, and Flammability Studies on Surface Modified Sisal Fiber Reinforced Recycled Polypropylene Composites

    Directory of Open Access Journals (Sweden)

    Arun Kumar Gupta

    2012-01-01

    Full Text Available The effect of surface treated sisal fiber on the mechanical, thermal, flammability, and morphological properties of sisal fiber (SF reinforced recycled polypropylene (RPP composites was investigated. The surface of sisal fiber was modified with different chemical reagent such as silane, glycidyl methacrylate (GMA, and O-hydroxybenzene diazonium chloride (OBDC to improve the compatibility with the matrix polymer. The experimental results revealed an improvement in the tensile strength to 11%, 20%, and 31.36% and impact strength to 78.72%, 77%, and 81% for silane, GMA, and OBDC treated sisal fiber reinforced recycled Polypropylene (RPP/SF composites, respectively, as compared to RPP. The thermogravimetric analysis (TGA, differential scanning calorimeter (DSC, and heat deflection temperature (HDT results revealed improved thermal stability as compared with RPP. The flammability behaviour of silane, GMA, and OBDC treated SF/RPP composites was studied by the horizontal burning rate by UL-94. The morphological analysis through scanning electron micrograph (SEM supports improves surface interaction between fiber surface and polymer matrix.

  5. Evaluation of the Thermophysical Properties of Poly(MethylMethacrylate): A Reference Material for the Development of a flammability Test for Micro-Gravity Environments

    OpenAIRE

    Steinhaus, Thomas

    1999-01-01

    A study has been conducted using PMMA (Poly(methyl methacrylate)) as a reference material in the development process of the Forced Flow and flame Spread Test (FIST). This test attempts to establish different criteria for material flammability for micro-gravity environments. The FIST consists of two tests, ignition and flame spread tests, that provide a series of material “fire” properties that jointly provide important information on the flammability of a material. This work de...

  6. Estimation of the lower flammability limit of organic compounds as a function of temperature.

    Science.gov (United States)

    Rowley, J R; Rowley, R L; Wilding, W V

    2011-02-15

    A new method of estimating the lower flammability limit (LFL) of general organic compounds is presented. The LFL is predicted at 298 K for gases and the lower temperature limit for solids and liquids from structural contributions and the ideal gas heat of formation of the fuel. The average absolute deviation from more than 500 experimental data points is 10.7%. In a previous study, the widely used modified Burgess-Wheeler law was shown to underestimate the effect of temperature on the lower flammability limit when determined in a large-diameter vessel. An improved version of the modified Burgess-Wheeler law is presented that represents the temperature dependence of LFL data determined in large-diameter vessels more accurately. When the LFL is estimated at increased temperatures using a combination of this model and the proposed structural-contribution method, an average absolute deviation of 3.3% is returned when compared with 65 data points for 17 organic compounds determined in an ASHRAE-style apparatus. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. ASTM Committee G-4 metals flammability test program - Data and discussion

    Science.gov (United States)

    Stoltzfus, Joel M.; Homa, John M.; Williams, Ralph E.; Benz, Frank J.

    1988-01-01

    Results of metals flammability tests performed on twenty-six metals in the NASA/White Sands Test Facility are discussed together with the test systems. The promoted combustion and ignition characteristics of these metals are described, and the metals are ranked according to their suitability for use in oxygen systems. In general, alloys with high copper and nickel contents and low iron content were found to rank higher than those that had high iron content, while alloys that had high aluminum content were ranked the lowest.

  8. Flammable gas double shell tank expert elicitation presentations (Part A and Part B)

    Energy Technology Data Exchange (ETDEWEB)

    Bratzel, D.R.

    1998-04-17

    This document is a compilation of presentation packages and white papers for the Flammable Gas Double Shell Tank Expert Elicitation Workshop {number_sign}2. For each presentation given by the different authors, a separate section was developed. The purpose for issuing these workshop presentation packages and white papers as a supporting document is to provide traceability and a Quality Assurance record for future reference to these packages.

  9. Flammable gas double shell tank expert elicitation presentations (Part A and Part B)

    International Nuclear Information System (INIS)

    Bratzel, D.R.

    1998-01-01

    This document is a compilation of presentation packages and white papers for the Flammable Gas Double Shell Tank Expert Elicitation Workshop number-sign 2. For each presentation given by the different authors, a separate section was developed. The purpose for issuing these workshop presentation packages and white papers as a supporting document is to provide traceability and a Quality Assurance record for future reference to these packages

  10. A highly conductive, non-flammable polymer–nanoparticle hybrid electrolyte

    KAUST Repository

    Agrawal, Akanksha

    2015-01-01

    © 2015 The Royal Society of Chemistry. We report on the physical properties of lithium-ion conducting nanoparticle-polymer hybrid electrolytes created by dispersing bidisperse mixtures of polyethylene glycol (PEG)-functionalized silica nanoparticles in an aprotic liquid host. At high particle contents, we find that the ionic conductivity is a non-monotonic function of the fraction of larger particles xL in the mixtures, and that for the nearly symmetric case xL ≈ 0.5 (i.e. equal volume fraction of small and large particles), the room temperature ionic conductivity is nearly ten-times larger than in similar nanoparticle hybrid electrolytes comprised of the pure small (xL ≈ 0) or large (xL ≈ 1) particle components. Complementary trends are seen in the activation energy for ion migration and effective tortuosity of the electrolytes, which both exhibit minima near xL ≈ 0.5. Characterization of the electrolytes by dynamic rheology reveals that the maximum conductivity coincides with a distinct transition in soft glassy properties from a jammed to partially jammed and back to jammed state, as the fraction of large particles is increased from 0 to 1. This finding implies that the conductivity enhancement arises from purely entropic loss of correlation between nanoparticle centers arising from particle size dispersity. As a consequence of these physics, it is now possible to create hybrid electrolytes with MPa elastic moduli and mS cm-1 ionic conductivity levels at room temperature using common aprotic liquid media as the electrolyte solvent. Remarkably, we also find that even in highly flammable liquid media, the bidisperse nanoparticle hybrid electrolytes can be formulated to exhibit low or no flammability without compromising their favorable room temperature ionic conductivity and mechanical properties.

  11. Computer systems and software description for Standard-E+ Hydrogen Monitoring System (SHMS-E+)

    International Nuclear Information System (INIS)

    Tate, D.D.

    1997-01-01

    The primary function of the Standard-E+ Hydrogen Monitoring System (SHMS-E+) is to determine tank vapor space gas composition and gas release rate, and to detect gas release events. Characterization of the gas composition is needed for safety analyses. The lower flammability limit, as well as the peak burn temperature and pressure, are dependent upon the gas composition. If there is little or no knowledge about the gas composition, safety analyses utilize compositions that yield the worst case in a deflagration or detonation. Knowledge of the true composition could lead to reductions in the assumptions and therefore there may be a potential for a reduction in controls and work restrictions. Also, knowledge of the actual composition will be required information for the analysis that is needed to remove tanks from the Watch List. Similarly, the rate of generation and release of gases is required information for performing safety analyses, developing controls, designing equipment, and closing safety issues. This report outlines the computer system design layout description for the Standard-E+ Hydrogen Monitoring System

  12. Flammable gas tank waste level reconcilliation tank 241-SX-102

    International Nuclear Information System (INIS)

    Brevick, C.H.; Gaddie, L.A.

    1997-01-01

    Fluoro Dynel Northwest (FDNW) was authorized to address flammable gas issues by reconciling the unexplained surface level increases in Tank 24 1-S-1 1 1 (S-I 1 1, typical). The trapped gas evaluation document (ref 1) states that Tank SX-102 exceeds the 25% of the lower flammable limit (FL) criterion (ref 2), based on a surface level rise evaluation. The Waste Storage Tank Status and Leak Detection Criteria document, commonly referred to as the ''Wallet Report'' is the basis for this letter report (ref 3). The Wallet Report is also a part of the trapped gas evaluation document criteria. The Wallet Report contains various tank information, including: physical information, status, levels, and dry wells, see Appendix A. The unexplained waste level rises were attributed to the production and retention of gas in the column of waste corresponding to the unacquainted for surface level rise. From 1973 through 1980, the Wallet Report tracked Tank S- 102 transfers and reported a net cumulative change of 19.95 in. This surface level increase is from an unknown source or is unacquainted for. Duke Engineering and Services Hanford (DASH) and Leached Martin Hanford Corporation (LMHC) are interested in determining the validity of the unexplained surface level changes reported in the 0611e Wallet Report based upon other corroborative sources of data. The purpose of this letter report is to assemble detailed surface level and waste addition data from daily tank records, logbooks, and other corroborative data that indicate surface levels, and to reconcile the cumulative unacquainted for surface level changes as shown in the Wallet Report from 1973 through 1980

  13. 14 CFR 25.1182 - Nacelle areas behind firewalls, and engine pod attaching structures containing flammable fluid...

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Nacelle areas behind firewalls, and engine...: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Fire Protection § 25.1182 Nacelle areas behind firewalls... immediately behind the firewall, and each portion of any engine pod attaching structure containing flammable...

  14. Biogas utilization as flammable for internal combustion engine

    International Nuclear Information System (INIS)

    Cardenas, H.

    1995-01-01

    In this work the energetic potential stored in form of generated biogas of organic industrial wastes treatment is analyzed. Biogas utilization as flammable at internal combustion engine coupled to electrical energy generating is studied in the Wastewater Treatment Plant of Bucaramanga city (Colombia). This Plant was designed for 160.000 habitants treatment capacity, 1300 m3/h wealth, 170 BDO/m3 residues concentration and 87% process efficiency. The plant generate 2.000 m3/d of biogas. In laboratory trials was worked with biogas originating from Treatment Plant, both without purifying and purified, and the obtained results were compared with both yields determined with 86-octanes gasoline and natural gas. The analysis of pollutant by-products generated in combustion process as leak gases, present corrosive compounds and not desirable. elements in biogas composition are included

  15. Flammable gas safety program

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Steele, R.

    1994-01-01

    This report describes the status of developing analytical methods to account for the organic constituents in Hanford waste tanks, with particular emphasis on those tanks that have been assigned to the Flammable Gas Watch List. Six samples of core segments from Tank 101-SY, obtained during the window E core sampling, have been analyzed for organic constituents. Four of the samples were from the upper region, or convective layer, of the tank and two were from the lower, nonconvective layer. The samples were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry (GC/MS). The major components detected were ethylenediaminetetraacetic acid (EDTA), nitroso-iminodiacetic acid (NIDA), nitrilotriacetic acid (NTA), citric acid (CA), succinic acid (SA), and ethylenediaminetriacetic acid (ED3A). The chelator of highest concentration was EDTA in all six samples analyzed. Liquid chromatography (LC) was used to quantitate low molecular weight acids (LMWA) including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon (TOC) in the samples analyzed was accounted for by these acids. Oxalate constituted approximately 40% of the TOC in the nonconvective layer samples. Oxalate was found to be approximately 3 to 4 times higher in concentration in the nonconvective layer than in the convective layer. During FY 1993, LC methods for analyzing LWMA, and two chelators N-(2-hydroxyethyl) ethylenediaminetriacetic acid and EDTA, were transferred to personnel in the Analytical Chemistry Laboratory and the 222-S laboratory

  16. A Method for Assessing Material Flammability for Micro-Gravity Environments

    Science.gov (United States)

    Steinhaus, T.; Olenick, S. M.; Sifuentes, A.; Long, R. T.; Torero, J. L.

    1999-01-01

    On a spacecraft, one of the greatest fears during a mission is the outbreak of a fire. Since spacecraft are enclosed spaces and depend highly on technical electronics, a small fire could cause a large amount of damage. NASA uses upward flame spread as a "worst case scenario" evaluation for materials and the Heat and Visible Smoke Release Rates Test to assess the damage potential of a fire. Details of these tests and the protocols followed are provided by the "Flammability, Odor, Offgassing, and Compatibility Requirements and Test Procedures for Materials in Environments that Support Combustion" document. As pointed by Ohlemiller and Villa, the upward flame spread test does not address the effect of external radiation on ignition and spread. External radiation, as that coming from an overheated electrical component, is a plausible fire scenario in a space facility and could result in a reversal of the flammability rankings derived from the upward flame spread test. The "Upward Flame Propagation Test" has been the subject of strong criticism in the last few years. In many cases, theoretical exercises and experimental results have demonstrated the possibility of a reversal in the material flammability rankings from normal to micro-gravity. Furthermore, the need to incorporate information on the effects of external radiation and opposed flame spread when ranking materials based on their potential to burn in micro-gravity has been emphasized. Experiments conducted in a 2.2 second drop tower with an ethane burner in an air cross flow have emphasized that burning at the trailing edge is deterred in micro-gravity due to the decreased oxygen transport. For very low air flow velocities (U0.01 m/s). Only for U>0.l m/s extinction is observed at the leading edge (blow-off). Three dimensional numerical calculations performed for thin cellulose centrally ignited with an axisymmetric source have shown that under the presence of a forced flow slower than 0.035 m/s flames spreads

  17. Investigation of flammable gas and thermal safety issues for retrieval of waste from Tank 241-AN-105

    Energy Technology Data Exchange (ETDEWEB)

    Caley, S.M.; Stewart, C.W.; Antoniak, Z.I.; Cuta, J.M.; Mahoney, L.A.; Panisko, F.E.

    1998-09-01

    The primary purpose of this report is to identify and resolve some of the flammable gas and thermal safety issues potentially associated with the retrieval of waste from Tank 241-AN-105 (AN-105), which is the first double-shell tank scheduled for waste retrieval at Hanford. The planned retrieval scenario includes the following steps in AN-105: (1) degas the tank using two submerged mixing pumps, (2) turn off the mixer pump(s) and allow any suspended solids to settle, (3) decant the supernatant to the intermediate feed staging tank(s) (IFSTs) (AP-102 and/or AP-104) using water/caustic dilution at the transfer pump inlet, (4) add the remaining dilution water/caustic to the slurry remaining in AN-105, (5) mix the tank with the mixer pump(s) until the soluble solids dissolve, (6) turn off the mixer pump(s) and let the insoluble solids settle, and (7) decant the new supernatant to the IFST(s), leaving the insoluble solids behind. Three waste retrieval safety issues are addressed in this report. They are (1) the controlled degassing of AN-105 to ensure that the headspace remains <25% of the lower flammability limit (LFL), (2) an assessment of how dissolved gas (mainly ammonia) released during the transfer of the supernatant in AN-105 to the IFSTs and the water/caustic dilution of the remaining slurry in AN-105 will affect the flammability in these tanks; and (3) an assessment of the maximum waste temperatures that might occur in AN-105 during retrieval operations.

  18. Investigation of flammable gas and thermal safety issues for retrieval of waste from Tank 241-AN-105

    International Nuclear Information System (INIS)

    Caley, S.M.; Stewart, C.W.; Antoniak, Z.I.; Cuta, J.M.; Mahoney, L.A.; Panisko, F.E.

    1998-09-01

    The primary purpose of this report is to identify and resolve some of the flammable gas and thermal safety issues potentially associated with the retrieval of waste from Tank 241-AN-105 (AN-105), which is the first double-shell tank scheduled for waste retrieval at Hanford. The planned retrieval scenario includes the following steps in AN-105: (1) degas the tank using two submerged mixing pumps, (2) turn off the mixer pump(s) and allow any suspended solids to settle, (3) decant the supernatant to the intermediate feed staging tank(s) (IFSTs) (AP-102 and/or AP-104) using water/caustic dilution at the transfer pump inlet, (4) add the remaining dilution water/caustic to the slurry remaining in AN-105, (5) mix the tank with the mixer pump(s) until the soluble solids dissolve, (6) turn off the mixer pump(s) and let the insoluble solids settle, and (7) decant the new supernatant to the IFST(s), leaving the insoluble solids behind. Three waste retrieval safety issues are addressed in this report. They are (1) the controlled degassing of AN-105 to ensure that the headspace remains <25% of the lower flammability limit (LFL), (2) an assessment of how dissolved gas (mainly ammonia) released during the transfer of the supernatant in AN-105 to the IFSTs and the water/caustic dilution of the remaining slurry in AN-105 will affect the flammability in these tanks; and (3) an assessment of the maximum waste temperatures that might occur in AN-105 during retrieval operations

  19. Flammable gas tank waste level reconciliation tank 241-SX-105

    International Nuclear Information System (INIS)

    Brevick, C.H.; Gaddie, L.A.

    1997-01-01

    Fluor Daniel Northwest was authorized to address flammable gas issues by reconciling the unexplained surface level increases in Tank 241-SX-105 (SX-105, typical). The trapped gas evaluation document states that Tank SX-105 exceeds the 25% of the lower flammable limit criterion, based on a surface level rise evaluation. The Waste Storage Tank Status and Leak Detection Criteria document, commonly referred to as the Welty Report is the basis for this letter report. The Welty Report is also a part of the trapped gas evaluation document criteria. The Welty Report contains various tank information, including: physical information, status, levels, and dry wells. The unexplained waste level rises were attributed to the production and retention of gas in the column of waste corresponding to the unaccounted for surface level rise. From 1973 through 1980, the Welty Report tracked Tank SX-105 transfers and reported a net cumulative change of 20.75 in. This surface level increase is from an unknown source or is unaccounted for. Duke Engineering and Services Hanford and Lockheed Martin Hanford Corporation are interested in determining the validity of unexplained surface level changes reported in the Welty Report based upon other corroborative sources of data. The purpose of this letter report is to assemble detailed surface level and waste addition data from daily tank records, logbooks, and other corroborative data that indicate surface levels, and to reconcile the cumulative unaccounted for surface level changes as shown in the Welty Report from 1973 through 1980. Tank SX-105 initially received waste from REDOX starting the second quarter of 1955. After June 1975, the tank primarily received processed waste (slurry) from the 242-S Evaporator/Crystallizer and transferred supernate waste to Tanks S-102 and SX-102. The Welty Report shows a cumulative change of 20.75 in. from June 1973 through December 1980

  20. The effect of the environment conditions on the prediction of flammable cloud dispersion

    OpenAIRE

    Schleder, Adriana; Martins, Marcelo; Pastor Ferrer, Elsa; Planas Cuchi, Eulàlia

    2014-01-01

    In order to quantify the damage caused by undesired events involving leakages of flammable materials, specific models are used to analyze the spills or jets of gas and liquid, gas dispersion, explosions and fires. The main step of this analysis is to estimate the concentration, in space and time, of the vapor cloud of hazardous substances released into the atmosphere; the purpose is to determine the area where a fire or explosion might occur and the quantity of flam...

  1. Group-Contribution based Property Estimation and Uncertainty analysis for Flammability-related Properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Marcarie, Camille; Abildskov, Jens

    2016-01-01

    regression and outlier treatment have been applied to achieve high accuracy. Furthermore, linear error propagation based on covariance matrix of estimated parameters was performed. Therefore, every estimated property value of the flammability-related properties is reported together with its corresponding 95......%-confidence interval of the prediction. Compared to existing models the developed ones have a higher accuracy, are simple to apply and provide uncertainty information on the calculated prediction. The average relative error and correlation coefficient are 11.5% and 0.99 for LFL, 15.9% and 0.91 for UFL, 2...

  2. Laminar burning velocities of near-flammability-limit H2-air-steam mixtures

    International Nuclear Information System (INIS)

    Loesel Sitar, J.V.; Chan, C.K.; Torchia, F.; Guerrero, A.

    1995-01-01

    Laminar burning velocities of lean H 2 -air-steam mixtures near the flammability limit were measured by using the pressure-time history of an expanding flame kernel. Although flames in these mixtures are inherently unstable, this difficulty was avoided by using the early pressure rise of the burn. A comparison of results from that method with burning velocities determined from schlieren photographs of the expanding flame kernel gave good agreement. Despite the difficulties, it is believed that the pressure trace method gives results that are useful in modelling reactor accident scenarios. 8 refs., 4 figs

  3. An approximate-reasoning-based method for screening high-level waste tanks for flammable gas

    International Nuclear Information System (INIS)

    Eisenhawer, S.W.; Bott, T.F.; Smith, R.E.

    1998-01-01

    The in situ retention of flammable gas produced by radiolysis and thermal decomposition in high-level waste can pose a safety problem if the gases are released episodically into the dome space of a storage tank. Screening efforts at Hanford have been directed at identifying tanks in which this situation could exist. Problems encountered in screening motivated an effort to develop an improved screening methodology. Approximate reasoning (AR) is a formalism designed to emulate the kinds of complex judgments made by subject matter experts. It uses inductive logic structures to build a sequence of forward-chaining inferences about a subject. AR models incorporate natural language expressions known as linguistic variables to represent evidence. The use of fuzzy sets to represent these variables mathematically makes it practical to evaluate quantitative and qualitative information consistently. The authors performed a pilot study to investigate the utility of AR for flammable gas screening. They found that the effort to implement such a model was acceptable and that computational requirements were reasonable. The preliminary results showed that important judgments about the validity of observational data and the predictive power of models could be made. These results give new insights into the problems observed in previous screening efforts

  4. An Approximate Reasoning-Based Method for Screening High-Level-Waste Tanks for Flammable Gas

    International Nuclear Information System (INIS)

    Eisenhawer, Stephen W.; Bott, Terry F.; Smith, Ronald E.

    2000-01-01

    The in situ retention of flammable gas produced by radiolysis and thermal decomposition in high-level waste can pose a safety problem if the gases are released episodically into the dome space of a storage tank. Screening efforts at the Hanford site have been directed at identifying tanks in which this situation could exist. Problems encountered in screening motivated an effort to develop an improved screening methodology. Approximate reasoning (AR) is a formalism designed to emulate the kinds of complex judgments made by subject matter experts. It uses inductive logic structures to build a sequence of forward-chaining inferences about a subject. Approximate-reasoning models incorporate natural language expressions known as linguistic variables to represent evidence. The use of fuzzy sets to represent these variables mathematically makes it practical to evaluate quantitative and qualitative information consistently. In a pilot study to investigate the utility of AR for flammable gas screening, the effort to implement such a model was found to be acceptable, and computational requirements were found to be reasonable. The preliminary results showed that important judgments about the validity of observational data and the predictive power of models could be made. These results give new insights into the problems observed in previous screening efforts

  5. An approximate reasoning-based method for screening high-level-waste tanks for flammable gas

    International Nuclear Information System (INIS)

    Eisenhawer, S.W.; Bott, T.F.; Smith, R.E.

    2000-01-01

    The in situ retention of flammable gas produced by radiolysis and thermal decomposition in high-level waste can pose a safety problem if the gases are released episodically into the dome space of a storage tank. Screening efforts at the Hanford site have been directed at identifying tanks in which this situation could exist. Problems encountered in screening motivated an effort to develop and improved screening methodology. Approximate reasoning (AR) is a formalism designed to emulate the kinds of complex judgments made by subject matter experts. It uses inductive logic structures to build a sequence of forward-chaining inferences about a subject. Approximate-reasoning models incorporate natural language expressions known as linguistic variables to represent evidence. The use of fuzzy sets to represent these variables mathematically makes it practical to evaluate quantitative and qualitative information consistently. In a pilot study to investigate the utility of AR for flammable gas screening, the effort to implement such a model was found to be acceptable, and computational requirements were found to be reasonable. The preliminary results showed that important judgments about the validity of observational data and the predictive power of models could be made. These results give new insights into the problems observed in previous screening efforts

  6. An approximate reasoning-based method for screening high-level-waste tanks for flammable gas

    Energy Technology Data Exchange (ETDEWEB)

    Eisenhawer, S.W.; Bott, T.F.; Smith, R.E.

    2000-06-01

    The in situ retention of flammable gas produced by radiolysis and thermal decomposition in high-level waste can pose a safety problem if the gases are released episodically into the dome space of a storage tank. Screening efforts at the Hanford site have been directed at identifying tanks in which this situation could exist. Problems encountered in screening motivated an effort to develop and improved screening methodology. Approximate reasoning (AR) is a formalism designed to emulate the kinds of complex judgments made by subject matter experts. It uses inductive logic structures to build a sequence of forward-chaining inferences about a subject. Approximate-reasoning models incorporate natural language expressions known as linguistic variables to represent evidence. The use of fuzzy sets to represent these variables mathematically makes it practical to evaluate quantitative and qualitative information consistently. In a pilot study to investigate the utility of AR for flammable gas screening, the effort to implement such a model was found to be acceptable, and computational requirements were found to be reasonable. The preliminary results showed that important judgments about the validity of observational data and the predictive power of models could be made. These results give new insights into the problems observed in previous screening efforts.

  7. Mass loss and flammability of insulation materials used in sandwich panels during the pre-flashover phase of fire

    NARCIS (Netherlands)

    Giunta d'Albani, A.W.; de Kluiver, L.L.; de Korte, A.C.J.; van Herpen, R.; Weewer, R.; Brouwers, H.J.H.

    2017-01-01

    Nowadays, buildings contain more and more synthetic insulation materials in order to meet the increasing energy-performance demands. These synthetic insulation materials have a different response to fire. In this study, the mass loss and flammability limits of different sandwich panels and their

  8. [Forensic medical evaluation of a burn injury from combustion of flammable fluids on the human body based on morphological changes in internal organs].

    Science.gov (United States)

    Khushkadamov, Z K

    2009-01-01

    The author describes morphological features of splanchnic organs in the patients that suffered an injury from combustion of flammable fluids at the body surface. The burn injury is a specific form of trauma originating from a combination of several injurious factors including thermoinhalation and intoxication with combustion products in the absence of oxygen in the centre of the hot spot. A rather specific combination of morphological changes in internal organs along with results of laboratory studies provides the most reliable criterion for forensic medical diagnosis of burn injuries from combustion of flammable fluids on the human body.

  9. Operation of the multigap resistive plate chamber using a gas mixture free of flammable components

    CERN Document Server

    Akindinov, A; Antonioli, P; Arcelli, S; Basile, M; Cara Romeo, G; Cifarelli, Luisa; Cindolo, F; De Caro, A; De Pasquale, S; Di Bartolomeo, A; Fusco-Girard, M; Golovine, V; Guida, M; Hatzifotiadou, D; Kaidalov, A B; Kim, D H; Kim, D W; Kisselev, S M; Laurenti, G; Lee, K; Lee, S C; Lioublev, E; Luvisetto, M L; Margotti, A; Martemyanov, A N; Nania, R; Noferini, F; Otiougova, P; Pesci, A; Pinazza, O; Polozov, P A; Scapparone, E; Scioli, G; Sellitto, S B; Semeria, F; Smirnitsky, A V; Tchoumakov, M M; Usenko, E; Valenti, G; Voloshin, K G; Williams, M C S; Zagreev, B V; Zampolli, C; Zichichi, A

    2004-01-01

    We have investigated the operation of the multigap resistive plate chamber (MRPC) for the ALICE-TOF system with a gas mixture free of flammable components. Two different gas mixtures, with and without iso-C//4H//1//0 have been used to measure the performance of the MRPC. The efficiency, time resolution, total charge, and the fast to total charge ratio have been found to be comparable.

  10. Thermoplastic Polyurethane Elastomer Nanocomposites: Morphology, Thermophysical, and Flammability Properties

    Directory of Open Access Journals (Sweden)

    Wai K. Ho

    2010-01-01

    Full Text Available Novel materials based on nanotechnology creating nontraditional ablators are rapidly changing the technology base for thermal protection systems. Formulations with the addition of nanoclays and carbon nanofibers in a neat thermoplastic polyurethane elastomer (TPU were melt-compounded using twin-screw extrusion. The TPU nanocomposites (TPUNs are proposed to replace Kevlar-filled ethylene-propylene-diene-monomer rubber, the current state-of-the-art solid rocket motor internal insulation. Scanning electron microscopy analysis was conducted to study the char characteristics of the TPUNs at elevated temperatures. Specimens were examined to analyze the morphological microstructure during the pyrolysis reaction and in fully charred states. Thermophysical properties of density, specific heat capacity, thermal diffusivity, and thermal conductivity of the different TPUN compositions were determined. To identify dual usage of these novel materials, cone calorimetry was employed to study the flammability properties of these TPUNs.

  11. Effect of swelling behavior of organoclays in styrene on flammability of polystyrene nanocomposites obtained through in situ incorporation

    International Nuclear Information System (INIS)

    Timochenco, Licinia; Sayer, Claudia; Machado, Ricardo A.F.; Araujo, Pedro H.H.

    2009-01-01

    In this work the effect of the interaction between organoclays and styrene on the flammability of polystyrene/clay nanocomposites obtained through in-situ incorporation was investigated. The reactions were carried out in bulk polymerization. The interaction between organoclays and styrene was inferred by swelling of the organoclay in styrene. The nanocomposites were characterized by X-ray diffraction and Transmission Electron Microscopy. The heat release rate was obtained by Cone Calorimeter and the nanocomposites were tested through UL94 horizontal burn test. Thermogravimetric analysis were also performed. Results showed that intercalated and partially exfoliated nanocomposites were obtained depending on the swelling behavior of the organoclay in styrene. It was also observed an increase of the higher decomposition temperature and an accentuated decrease on the peak of heat release of the nanocomposites when comparing to the virgin polymer. No remarkable effect between the swelling behavior of the organoclay in styrene and the flammability properties was observed. (author)

  12. Effect of Meltable Triazine-DOPO Additive on Rheological, Mechanical, and Flammability Properties of PA6

    Directory of Open Access Journals (Sweden)

    Irina Butnaru

    2015-08-01

    Full Text Available Through a straightforward approach, a new meltable, halogen-free, nitrogen-phosphorus-based flame retardant (FR, 6-(2-(4,6-diamino-1,3,5-triazin-2-ylethyl dibenzo[c,e][1,2]oxaphosphinine 6-oxide (DTE-DOPO was synthesized and incorporated in polyamide 6 (PA6. It was proved that a very low phosphorus content of 1.46 wt% for DTE-DOPO additive improved the flame retardancy of PA6, leading to a non-flammable material. The performance of the new additive was compared to that of the commercially-available Exolit® OP 1230. The PA6 formulations were evaluated by measuring the rheological, mechanical, and flammability behavior. Using compounding by melt extrusion, 17 wt% additives was introduced into PA6 matrix and the corresponding formulations were characterized. The results evidenced a higher homogeneity of DTE-DOPO with PA6, a high thermal stability with a catalyzing decomposition effect on PA6 caused by the presence of the new developed FR, enhanced elasticity for the PA6/DTE-DOPO formulation and a V0 rating for both formulations. Thermal and fire analysis indicated a primary gas-phase activity, combined with a complete suppression of the self-sustained burning for the PA6/DTE-DOPO formulation.

  13. 77 FR 64055 - Safety Standard for Bassinets and Cradles

    Science.gov (United States)

    2012-10-18

    ... after an infant's body, but not head, slipped through the fabric covering and underlying structural... odors, to product assembly/quality issues. Twenty-seven (about 8 percent) of the incidents reported... mattresses that are also inclined in a manner that elevates the head, as well as conforming to the body...

  14. Influence of dispersion degree of water drops on efficiency of extinguishing of flammable liquids

    OpenAIRE

    Korolchenko Dmitriy; Voevoda Sergey

    2016-01-01

    Depending on the size of water drops, process of fire extinguishing is focused either in a zone of combustion or on a burning liquid surface. This article considers two alternate solutions of a heat balance equation. The first solution allows us to trace decrease of temperature of a flammable liquid (FL) surface to a temperature lower than fuel flash point at which combustion is stopped. And the second solution allows us to analyze decrease of burnout rate to a negligible value at which steam...

  15. Report on the handling of safety information concerning flammable gases and ferrocyanide at the Hanford waste tanks

    International Nuclear Information System (INIS)

    1990-07-01

    This report discusses concerns safety issues, and management at Hanford Tank Farm. Concerns center on the issue of flammable gas generation which could ignite, and on possible exothermic reactions of ferrocyanide compounds which were added to single shell tanks in the 1950's. It is believed that information concerning these issues has been mis-handled and the problems poorly managed

  16. Report on the handling of safety information concerning flammable gases and ferrocyanide at the Hanford waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-01

    This report discusses concerns safety issues, and management at Hanford Tank Farm. Concerns center on the issue of flammable gas generation which could ignite, and on possible exothermic reactions of ferrocyanide compounds which were added to single shell tanks in the 1950's. It is believed that information concerning these issues has been mis-handled and the problems poorly managed. (CBS)

  17. Laminar burning velocities of near-flammability-limit H{sub 2}-air-steam mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Loesel Sitar, J V; Chan, C K; Torchia, F; Guerrero, A

    1996-12-31

    Laminar burning velocities of lean H{sub 2}-air-steam mixtures near the flammability limit were measured by using the pressure-time history of an expanding flame kernel. Although flames in these mixtures are inherently unstable, this difficulty was avoided by using the early pressure rise of the burn. A comparison of results from that method with burning velocities determined from schlieren photographs of the expanding flame kernel gave good agreement. Despite the difficulties, it is believed that the pressure trace method gives results that are useful in modelling reactor accident scenarios. 8 refs., 4 figs.

  18. Flammability of Cellulose-Based Fibers and the Effect of Structure of Phosphorus Compounds on Their Flame Retardancy

    Directory of Open Access Journals (Sweden)

    Khalifah A. Salmeia

    2016-08-01

    Full Text Available Cellulose fibers are promoted for use in various textile applications due their sustainable nature. Cellulose-based fibers vary considerably in their mechanical and flammability properties depending on their chemical composition. The chemical composition of a cellulose-based fiber is further dependent on their source (i.e., seed, leaf, cane, fruit, wood, bast, and grass. Being organic in nature, cellulose fibers, and their products thereof, pose considerable fire risk. In this work we have compared the flammability properties of cellulose fibers obtained from two different sources (i.e., cotton and peat. Compared to cotton cellulose textiles, peat-based cellulose textiles burn longer with a prominent afterglow which can be attributed to the presence of lignin in its structure. A series of phosphoramidates were synthesized and applied on both cellulose textiles. From thermogravimetric and pyrolysis combustion flow analysis of the treated cellulose, we were able to relate the flame retardant efficacy of the synthesized phosphorus compounds to their chemical structure. The phosphoramidates with methyl phosphoester groups exhibited higher condensed phase flame retardant effects on both types of cellulose textiles investigated in this study. In addition, the bis-phosphoramidates exhibited higher flame retardant efficacy compared to the mono-phosphoramidates.

  19. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  20. Early prevention of pressure ulcers among elderly patients admitted through emergency departments: a cost-effectiveness analysis.

    Science.gov (United States)

    Pham, Ba'; Teague, Laura; Mahoney, James; Goodman, Laurie; Paulden, Mike; Poss, Jeff; Li, Jianli; Ieraci, Luciano; Carcone, Steven; Krahn, Murray

    2011-11-01

    Every year, approximately 6.2 million hospital admissions through emergency departments (ED) involve elderly patients who are at risk of developing pressure ulcers. We evaluated the cost-effectiveness of pressure-redistribution foam mattresses on ED stretchers and beds for early prevention of pressure ulcers in elderly admitted ED patients. Using a Markov model, we evaluated the incremental effectiveness (quality-adjusted life-days) and incremental cost (hospital and home care costs) between early prevention and current practice (with standard hospital mattresses) from a health care payer perspective during a 1-year time horizon. The projected incidence of ED-acquired pressure ulcers was 1.90% with current practice and 1.48% with early prevention, corresponding to a number needed to treat of 238 patients. The average upgrading cost from standard to pressure-redistribution mattresses was $0.30 per patient. Compared with current practice, early prevention was more effective, with 0.0015 quality-adjusted life-days gained, and less costly, with a mean cost saving of $32 per patient. If decisionmakers are willing to pay $50,000 per quality-adjusted life-year gained, early prevention was cost-effective even for short ED stay (ie, 1 hour), low hospital-acquired pressure ulcer risk (1% prevalence), and high unit price of pressure-redistribution mattresses ($3,775). Taking input uncertainty into account, early prevention was 81% likely to be cost-effective. Expected value-of-information estimates supported additional randomized controlled trials of pressure-redistribution mattresses to eliminate the remaining decision uncertainty. The economic evidence supports early prevention with pressure-redistribution foam mattresses in the ED. Early prevention is likely to improve health for elderly patients and save hospital costs. Copyright © 2011 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  1. 16 CFR 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Science.gov (United States)

    2010-01-01

    ... flammable materials by Tagliabue open-cup apparatus. 1500.43 Section 1500.43 Commercial Practices CONSUMER... horizontal plane above the liquid may be used, as follows: (1) Guide wire, 3/32-inch in diameter and 31/2... the thermometer, and in a plane 1/8-inch above the upper edge of the cup. The taper should be kept in...

  2. Resolve. Version 2.5: Flammable Gas Accident Analysis Tool Acceptance Test Plan and Test Results

    International Nuclear Information System (INIS)

    LAVENDER, J.C.

    2000-01-01

    RESOLVE. Version 2 .5 is designed to quantify the risk and uncertainty of combustion accidents in double-shell tanks (DSTs) and single-shell tanks (SSTs). The purpose of the acceptance testing is to ensure that all of the options and features of the computer code run; to verify that the calculated results are consistent with each other; and to evaluate the effects of the changes to the parameter values on the frequency and consequence trends associated with flammable gas deflagrations or detonations

  3. The effect of the computational grid size on the prediction of a flammable cloud dispersion

    OpenAIRE

    Schleder, Adriana; Martins, Marcelon; Pastor Ferrer, Elsa; Planas Cuchi, Eulàlia

    2014-01-01

    The consequence analysis is used to define the extent and nature of effects caused by undesired events being of great help when quantifying the damage caused by such events. For the case of leaking of flammable and/or toxic materials, effects are analyzed for explosions, fires and toxicity. Specific models are used to analyze the spills or jets of gas or liquids, gas dispersions, explosions and fires. The central step in the analysis of consequences in such cases is to de...

  4. Standard-B auto grab sampler hydrogen monitoring system, Acceptance Test Report

    International Nuclear Information System (INIS)

    Lott, D.T.

    1995-01-01

    Project W-369, Watch List Tank Hydrogen Monitors, installed a Standard-C Hydrogen Monitoring System (SHMS) on the Flammable gas waste tank AN-104. General Support Projects (8K510) was support by Test Engineering (7CH30) in the performance of the Acceptance Test Procedures (ATP) to qualify the SHMS cabinets on the waste tank. The ATP's performance was controlled by Tank Farm work package. This completed ATP is transmitted by EDT-601748 as an Acceptance Test Report (ATR) in accordance with WHC-6-1, EP 4.2 and EP 1.12

  5. Short Communication. Comparing flammability traits among fire-stricken (low elevation and non fire-stricken (high elevation conifer forest species of Europe: A test of the Mutch hypothesis

    Directory of Open Access Journals (Sweden)

    A. P. Dimitrakopoulos

    2013-04-01

    Full Text Available Aim of study. The flammability of the main coniferous forest species of Europe, divided into two groups according to their fire regime and altitudinal distribution, was tested in an effort to detect species-specific differences that may have an influence on community-wide fire regimes.Area of study. Conifer species comprising low- and high-elevation forests in Europe.Materials and Methods. The following conifer species were tested: low elevation; Pinus halepensis (Aleppo pine, Pinus brutia (Turkish pine, Pinus pinaster (maritime pine, Pinus pinea (stone pine and Cupressus sempervirens (cypress, high elevation (i.e., above 600 m a.s.l.; Pinus sylvestris (Scots pine, Abies alba (white fir, Picea excelsa (Norway spruce, Abies borissii regis (Macedonian fir and Pinus nigra (black pine. Flammability assessment (time-to-ignition and ignition temperature was conducted by an innovative ignition apparatus, heat content was measured with an IKA Adiabatic Bomb Calorimeter and ash content by heating 5 g of plant material in a muffle furnace at 650ºC for 1 h. Differences among species was statistically analysed by Duncan’s multiple comparison test.Main results. The results did not distinguish separate groups among traits between fire- and non-fire-stricken communities at the individual species level.Research highlights. Differences in fire regimes among low and high elevation conifer forests could be attributed either to differences in flammability of the plant communities as a whole (i.e., fuelbed or canopy properties vs. individual fuel properties or to other factors (climatic or anthropogenic.Key words: flammability; ignitability; heat content; ash content; conifer species; Mutch hypothesis.

  6. Should care homes adopt a static-led approach to pressure ulcer prevention?

    Science.gov (United States)

    Keen, Delia Catherine

    A static-led approach refers to the provision of high-specification foam mattresses for the whole of a population at risk of pressure damage. Such mattresses have been found to reduce the risk of pressure ulceration and cost less overall than standard mattresses, even in populations where only 1 in 100 patients develops a pressure ulcer. Reduced pressure ulcer prevalence and reduced costs resulting from decreased expenditure on dynamic mattresses following the implementation of a static-led approach have been reported. Pressure ulcers cause pain, a reduced quality of life, loss of independence, depression and social isolation for those in whom they develop. Organizations are increasingly having to pay out large sums of money following litigation surrounding pressure ulcers. This article explains why NHS healthcare providers and private care organizations need to work together to consider implementing a static-led approach to pressure ulcer prevention within care homes in order to reduce pressure ulcer incidence cost-effectively within their local populations.

  7. Evaluation of comfort in bedridden older adults using an air-cell mattress with an automated turning function: measurement of parasympathetic activity during night sleep.

    Science.gov (United States)

    Futamura, Megumi; Sugama, Junko; Okuwa, Mayumi; Sanada, Hiromi; Tabata, Keiko

    2008-12-01

    This study objectively evaluated the degree of comfort in bedridden older adults using an air-cell mattress with an automated turning mechanism. The sample included 10 bedridden women with verbal communication difficulties. The high frequency (HF) components of heart rate variability, which reflect parasympathetic nervous activity, were compared for the manual and automated turning periods. No significant differences in the HF component were observed in 5 of the participants. Significant increases in the HF component associated with automated turning were observed in 3 participants; however, the two participants with the lowest body mass index values exhibited a significant reduction in the HF component during the automated turning period. The results revealed that comfort might not be disturbed during the automated turning period.

  8. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks; TOPICAL

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  9. An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity and Extraterrestrial Fire-Safety Applications

    Science.gov (United States)

    Olson, S. L.; Beeson, H.; Haas, J. P.

    2003-01-01

    The objective of this project is to modify the standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. This apparatus will allow us to conduct normal gravity experiments that accurately and quantitatively evaluate a material's flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire configuration that provides a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by a flame in a spacecraft or extraterrestrial gravity level. Prototype unit testing results are presented in this paper. Ignition delay times and regression rates for PMMA are presented over a range of radiant heat flux levels and equivalent stretch rates which demonstrate the ability of ELSA to simulate key features of microgravity and extraterrestrial fire behavior.

  10. Modelling of hot surface ignition within gas turbines subject to flammable gas in the intake

    DEFF Research Database (Denmark)

    Pedersen, Lea Duedahl; Nielsen, Kenny Krogh; Yin, Chungen

    2017-01-01

    Controlling risks associated with fires and explosions from leaks of flammable fluids at oil and gas facilities is paramount to ensuring safe operations. The gas turbine is a significant potential source of ignition; however, the residual risk is still not adequately understood. A model has been...... but decreases with increase in initial mixture temperature and pressure. The model shows a great potential in reliable prediction of the risk of hot surface ignition within gas turbines in the oil and gas industry. In the future, a dedicated experimental study will be performed not only to improve...

  11. Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules.

    Science.gov (United States)

    Yang, Hong-Yun; Zhou, Xiao-Dong; Yang, Li-Zhong; Zhang, Tao-Lin

    2015-07-09

    Many of the photovoltaic (PV) systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time ( t ig ), mass loss, heat release rate (HRR), carbon monoxide (CO) and carbon dioxide (CO₂) concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m². This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires.

  12. An Exploratory Study on a High-Energy Flux (HEF) Calorimeter to Characterize Flammability of Advanced Engineered Polymers: Phase 1 - Ignition and Mass Loss Rate

    National Research Council Canada - National Science Library

    Tewarson, A

    1999-01-01

    This report describes a newly designed high-energy flux (HEF) calorimeter for the flammability evaluation of high fire resistant plastics exposed to high heat flux typical of combat field scenarios and large-scale fires...

  13. Flammability of polypropylene/organoclay nanocomposites; Inflamabilidade de nanocompositos de polipropileno/argila organofilica

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Tatianny Soares; Barbosa, Renata [Universidade Federal do Piaui (UFPI), Teresina (Brazil); Carvalho, Laura Hecker de [Universidade Federal de Campina Grande (UFCG), PB (Brazil); Canedo, Eduardo Luis [Instituto de Tecnologia de Pernambuco, Recife (Brazil)

    2014-11-01

    The flammabilities of nanocomposites made with three polypropylene grades (homo and copolymers) with 5 wt % of organoclay (Cloisite 20A), 5 or 15 wt % of maleated polypropylene as compatibilizer, and 0, 0.5 or 1 wt % of cis-13-docosenamide (Erucamide) as co-intercalant, were studied using the horizontal burning test UL94HB. Masterbatches prepared in an internal mixer were diluted in the polypropylene matrix using a corotating twin-screw extruder, with different screw configurations and operating at 240 or 480 rpm. Results indicate that the high burning rate of the composites was not affected by the processing conditions. For all formulations was observed a significant reduction in smoke release, lack of dripping and the formation of a char surface layer, that protected the core of the samples. (author)

  14. 16 CFR 1632.2 - Purpose, scope, and applicability.

    Science.gov (United States)

    2010-01-01

    ... resistance of a mattress prototype or a mattress pad prototype. Use of the tests in §§ 1632.6 and 1632.7 is... prototype designs of mattresses and mattress pads before the sale in commerce or the introduction in... of a mattress prototype or a mattress pad prototype. (b) Scope. (1) All mattresses, as defined in...

  15. Prediction methods for the calculation of the flammability properties of gases and vapors: CHETAH and ASTM software. Part 1. Esters and Ethers

    International Nuclear Information System (INIS)

    Gigante, L.; Dellavedova, M.; Pasturenzi, C.; Lunghi, A.; Cardillo, P.

    2008-01-01

    After the law by decree of the 12. June 2003, N 233 (ATEX Directive) and REACH regulation (Regulation EC n. 2907/2006 of the European Parliament), several industrial fields, also not chemical, need the flammability data for the substances used. Perhaps, many of these data, especially for compounds with not common uses, are not easy to collect. It would be helpful to provide prediction methods in order to calculate these data without any experimentation that sometimes results time consuming, expensive and practically impossible for all the commercial compounds. In this research the ASTM software CHETAH (CHEmical Thermodynamic And Hazard evaluation) has been used in order to compute the lower flammability limit (L i ), the limiting oxygen concentration (LOC, using nitrogen as inert gas) as a function of temperature, the adiabatic flame temperature T flame , the fundamental burning velocity (S u ), the quenching distance (Q d ), the minimum ignition energy (MIE) for esters and ethers, substances highly used in industry. [it

  16. Altered community flammability in Florida's Apalachicola ravines and implications for the persistence of the endangered conifer Torreya taxifolia.

    Directory of Open Access Journals (Sweden)

    John M Mola

    Full Text Available Plant species and communities often reflect historic fire regimes via ecological and evolutionary responses to recurrent fires. Plant communities of the southeastern USA experience a wide array of fire regimes, perhaps nowhere more marked than the juxtaposition of fire-prone uplands and adjacent mesic ravines along Florida's Apalachicola River. The ravines contain many endemic and disjunct species, most notably the endangered endemic conifer Torreya taxifolia. A rapid decline in T. taxifolia over the past 60 years has been associated with widespread replacement by other tree species. To understand the changes accompanying the shift in ravine composition, we compared leaf litter flammability of nine historic and contemporary species. We measured maximum flame height, flame duration, smoldering duration, mass loss, absorptive capacity, and drying rate. Ordination and perMANOVA suggest the nine species segregated into three distinct groups: the fire-impeding T. taxifolia and Taxus floridana; an intermediate group of three deciduous angiosperms; and a mixed cluster of four flammable species. Results suggest T. taxifolia and T. floridana were fire-impeding species in these communities, while contemporary dominants burn similarly to the upslope pyric species. The increasing presence of fire-facilitating species may portend a shifting fire regime that further imperils T. taxifolia and other rare species in the formerly fire-safe ravines.

  17. Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules

    Directory of Open Access Journals (Sweden)

    Hong-Yun Yang

    2015-07-01

    Full Text Available Many of the photovoltaic (PV systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time (tig, mass loss, heat release rate (HRR, carbon monoxide (CO and carbon dioxide (CO2 concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m2. This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires.

  18. 16 CFR 1031.4 - Effect of voluntary standards activities on Commission activities.

    Science.gov (United States)

    2010-01-01

    ... Safety Act, the Federal Hazardous Substances Act, or the Flammable Fabrics Act, as may be applicable.... 2058, section 3(f) of the Federal Hazardous Substances Act, 15 U.S.C. 1262(f), or section 4(a) of the Flammable Fabrics Act, 15 U.S.C. 1193(g), as may be applicable. In commencing such a proceeding, the...

  19. 75 FR 22303 - Safety Standard for Bassinets and Cradles: Notice of Proposed Rulemaking

    Science.gov (United States)

    2010-04-28

    ... and conform to the body contours of the infant, whereas bassinets and cradles have flat mattresses... involved a host of miscellaneous problems, including a tear in the bassinet fabric, odors, and product... standing base and rock naturally. Most have sleep surfaces that curve, molding to an infant's body. However...

  20. Evaluation of the synergistic interaction between Decarbomobiphenyl Oxide and alumina on the flammability and thermal behavior of unsaturated polyester resin

    International Nuclear Information System (INIS)

    Al-Owias, A.; Al-Haizan, A.; Khattab, M. A.

    2005-01-01

    The bromine performance of decarbomobiphenyl oxide (DBBO) as a flame retardant for unsaturated polyester resin (UP) had been investigated in its own and in the presence of aluminum oxide (Al2O3) using UL-94V and Limiting Oxygen Index (LOI). Thermal behaviors of the resulted systems were evaluated using thermal analysis technique. DBBO showed a satisfactory fire retardant performance for UP, particularly when used at a loading higher than 30 wt%. In contrast aluminum oxide has no significant effect on the reduction of the flammability. Treatment of UP with mixtures containing different portioned of DBBO and alumina showed that, the best performance of these mixtures as a flame retardant occurred when the mixture is rich in DBBO. The maximum synergism between the two additives has been observed to occur at a weight ratio of DBBO to Al2O3 of 5:6. A possible explanation for the observed synergism between the two additives was given. The synergism was partly attributed to the formation of aluminum halide species which enhance the rate of halogen released from the halogenated compound and consequently reduce the flammability of the resin. (author)

  1. Support surfaces for pressure ulcer prevention.

    Science.gov (United States)

    McInnes, Elizabeth; Jammali-Blasi, Asmara; Bell-Syer, Sally E M; Dumville, Jo C; Middleton, Victoria; Cullum, Nicky

    2015-09-03

    Pressure ulcers (i.e. bedsores, pressure sores, pressure injuries, decubitus ulcers) are areas of localised damage to the skin and underlying tissue. They are common in the elderly and immobile, and costly in financial and human terms. Pressure-relieving support surfaces (i.e. beds, mattresses, seat cushions etc) are used to help prevent ulcer development. This systematic review seeks to establish:(1) the extent to which pressure-relieving support surfaces reduce the incidence of pressure ulcers compared with standard support surfaces, and,(2) their comparative effectiveness in ulcer prevention. In April 2015, for this fourth update we searched The Cochrane Wounds Group Specialised Register (searched 15 April 2015) which includes the results of regular searches of MEDLINE, EMBASE and CINAHL and The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2015, Issue 3). Randomised controlled trials (RCTs) and quasi-randomised trials, published or unpublished, that assessed the effects of any support surface for prevention of pressure ulcers, in any patient group or setting which measured pressure ulcer incidence. Trials reporting only proxy outcomes (e.g. interface pressure) were excluded. Two review authors independently selected trials. Data were extracted by one review author and checked by another. Where appropriate, estimates from similar trials were pooled for meta-analysis. For this fourth update six new trials were included, bringing the total of included trials to 59.Foam alternatives to standard hospital foam mattresses reduce the incidence of pressure ulcers in people at risk (RR 0.40 95% CI 0.21 to 0.74). The relative merits of alternating- and constant low-pressure devices are unclear. One high-quality trial suggested that alternating-pressure mattresses may be more cost effective than alternating-pressure overlays in a UK context.Pressure-relieving overlays on the operating table reduce postoperative pressure ulcer incidence

  2. A study of the dynamic flammability of radiation cross-linked flame-retardant HDPE/EPDM/silicon-elastomer compound

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Shaojin E-mail: jiashaojin2@yahoo.com.cn; Zhang Zhicheng E-mail: zczhang@ustc.edu.cn; Du Zhiwen; Teng Renrui; Wang Zhengzhou

    2003-04-01

    A dynamic flammability study of flame-retardant compound consisting of HDPE, EPDM and silicon elastomer blended with additives, as wire and cable insulation was made before and after irradiation. The data of RHR, EHC, SEC and the concentration of CO and CO{sub 2} from cone colorimeter shown in the burning process were accessed. By blending silicon elastomer, CO release rate was reduced and the thermal endurance was improved. Oxygen index, mechanical property, morphology of the char formed in dynamical flame and thermal stability were also investigated.

  3. A study of the dynamic flammability of radiation cross-linked flame-retardant HDPE/EPDM/silicon-elastomer compound

    International Nuclear Information System (INIS)

    Jia, Shaojin; Zhang Zhicheng; Du Zhiwen; Teng Renrui; Wang Zhengzhou

    2003-01-01

    A dynamic flammability study of flame-retardant compound consisting of HDPE, EPDM and silicon elastomer blended with additives, as wire and cable insulation was made before and after irradiation. The data of RHR, EHC, SEC and the concentration of CO and CO 2 from cone colorimeter shown in the burning process were accessed. By blending silicon elastomer, CO release rate was reduced and the thermal endurance was improved. Oxygen index, mechanical property, morphology of the char formed in dynamical flame and thermal stability were also investigated

  4. TRU waste transportation -- The flammable gas generation problem

    International Nuclear Information System (INIS)

    Connolly, M.J.; Kosiewicz, S.T.

    1997-01-01

    The Nuclear Regulatory Commission (NRC) has imposed a flammable gas (i.e., hydrogen) concentration limit of 5% by volume on transuranic (TRU) waste containers to be shipped using the TRUPACT-II transporter. This concentration is the lower explosive limit (LEL) in air. This was done to minimize the potential for loss of containment during a hypothetical 60 day period. The amount of transuranic radionuclide that is permissible for shipment in TRU waste containers has been tabulated in the TRUPACT-II Safety Analysis Report for Packaging (SARP, 1) to conservatively prevent accumulation of hydrogen above this 5% limit. Based on the SARP limitations, approximately 35% of the TRU waste stored at the Idaho National Engineering and Environmental Lab (INEEL), Los Alamos National Lab (LANL), and Rocky Flats Environmental Technology Site (RFETS) cannot be shipped in the TRUPACT-II. An even larger percentage of the TRU waste drums at the Savannah River Site (SRS) cannot be shipped because of the much higher wattage loadings of TRU waste drums in that site's inventory. This paper presents an overview of an integrated, experimental program that has been initiated to increase the shippable portion of the Department of Energy (DOE) TRU waste inventory. In addition, the authors will estimate the anticipated expansion of the shippable portion of the inventory and associated cost savings. Such projection should provide the TRU waste generating sites a basis for developing their TRU waste workoff strategies within their Ten Year Plan budget horizons

  5. Standard-D hydrogen monitoring system, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1996-01-01

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS

  6. 16 CFR 1615.1 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... part 1610) and the Standard for the Flammability of Vinyl Plastic Film (16 CFR part 1611); and (4... Clothing Textiles (16 CFR part 1610) and the Standard for the Flammability of Vinyl Plastic Film (16 CFR..., Virginia 22209. This document is also available for inspection at the National Archives and Records...

  7. Effect of Spacecraft Environmental Variables on the Flammability of Fire Resistant Fabrics

    Science.gov (United States)

    Osorio, A. F.; Fernandez-Pello, C.; Takahashi, S.; Rodriguez, J.; Urban, D. L.; Ruff, G.

    2012-01-01

    Fire resistant fabrics are used for firefighter, racecar drivers as well as astronaut suits. However, their fire resistant characteristics depend on the environment conditions and require study. Particularly important is the response of these fabrics to elevated oxygen concentration environments and radiant heat from a source such as an adjacent fire. In this work, experiments using two fire resistant fabrics were conducted to study the effect of oxygen concentration, external radiant flux and oxidizer flow velocity in concurrent flame spread. Results show that for a given fabric the minimum oxygen concentration for flame spread depends strongly on the magnitude of the external radiant flux. At increased oxygen concentrations the external radiant flux required for flame spread decreases. Oxidizer flow velocity influences the external radiant flux only when the convective heat flux from the flame has similar values to the external radiant flux. The results of this work provide further understanding of the flammability characteristics of fire resistant fabrics in environments similar to those of future spacecrafts.

  8. 16 CFR 1616.2 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... Flammability of Clothing Textiles (16 CFR part 1610) and the Standard for the Flammability of Vinyl Plastic... National Archives and Records Administration (NARA). For information on the availability of this material...

  9. Model of ASTM Flammability Test in Microgravity: Iron Rods

    Science.gov (United States)

    Steinberg, Theodore A; Stoltzfus, Joel M.; Fries, Joseph (Technical Monitor)

    2000-01-01

    There is extensive qualitative results from burning metallic materials in a NASA/ASTM flammability test system in normal gravity. However, this data was shown to be inconclusive for applications involving oxygen-enriched atmospheres under microgravity conditions by conducting tests using the 2.2-second Lewis Research Center (LeRC) Drop Tower. Data from neither type of test has been reduced to fundamental kinetic and dynamic systems parameters. This paper reports the initial model analysis for burning iron rods under microgravity conditions using data obtained at the LERC tower and modeling the burning system after ignition. Under the conditions of the test the burning mass regresses up the rod to be detached upon deceleration at the end of the drop. The model describes the burning system as a semi-batch, well-mixed reactor with product accumulation only. This model is consistent with the 2.0-second duration of the test. Transient temperature and pressure measurements are made on the chamber volume. The rod solid-liquid interface melting rate is obtained from film records. The model consists of a set of 17 non-linear, first-order differential equations which are solved using MATLAB. This analysis confirms that a first-order rate, in oxygen concentration, is consistent for the iron-oxygen kinetic reaction. An apparent activation energy of 246.8 kJ/mol is consistent for this model.

  10. Feather bedding and childhood asthma associated with house dust mite sensitisation: a randomised controlled trial.

    Science.gov (United States)

    Glasgow, Nicholas J; Ponsonby, Anne-Louise; Kemp, Andrew; Tovey, Euan; van Asperen, Peter; McKay, Karen; Forbes, Samantha

    2011-06-01

    Observational studies report inverse associations between the use of feather upper bedding (pillow and/or quilt) and asthma symptoms but there is no randomised controlled trial (RCT) evidence assessing the role of feather upper bedding as a secondary prevention measure. To determine whether, among children not using feather upper bedding, a new feather pillow and feather quilt reduces asthma severity among house dust mite (HDM) sensitised children with asthma over a 1-year period compared with standard dust mite avoidance advice, and giving children a new mite-occlusive mattress cover. RCT. The Calvary Hospital in the Australian Capital Territory and the Children's Hospital at Westmead, Sydney, New South Wales. 197 children with HDM sensitisation and moderate to severe asthma. Intervention New upper bedding duck feather pillow and quilt and a mite-occlusive mattress cover (feather) versus standard care and a mite-occlusive mattress cover (standard). The proportion of children reporting four or more episodes of wheeze in the past year; an episode of speech-limiting wheeze; or one or more episodes of sleep disturbance caused by wheezing; and spirometry with challenge testing. Statistical analysis included multiple logistic and linear regression. No differences between groups were found for primary end points--frequent wheeze (OR 1.51, 95% CI 0.83 to 2.76, p=0.17), speech-limiting wheeze (OR 0.70, 95% CI 0.32 to 1.48, p=0.35), sleep disturbed because of wheezing (OR 1.17, 95% CI 0.64 to 2.13, p=0.61) or for any secondary end points. Secondary analyses indicated the intervention reduced the risk of sleep being disturbed because of wheezing and severe wheeze to a greater extent for children who slept supine. No differences in respiratory symptoms or lung function were observed 1 year after children with moderate-severe asthma and HDM sensitisation were given a mite-occlusive mattress cover and then received either feather upper bedding (pillow and quilt) or standard

  11. Milestone Report #2: Direct Evaporator Leak and Flammability Analysis Modifications and Optimization of the Organic Rankine Cycle to Improve the Recovery of Waste Heat

    Energy Technology Data Exchange (ETDEWEB)

    Guillen, Donna Post [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-09-01

    The direct evaporator is a simplified heat exchange system for an Organic Rankine Cycle (ORC) that generates electricity from a gas turbine exhaust stream. Typically, the heat of the exhaust stream is transferred indirectly to the ORC by means of an intermediate thermal oil loop. In this project, the goal is to design a direct evaporator where the working fluid is evaporated in the exhaust gas heat exchanger. By eliminating one of the heat exchangers and the intermediate oil loop, the overall ORC system cost can be reduced by approximately 15%. However, placing a heat exchanger operating with a flammable hydrocarbon working fluid directly in the hot exhaust gas stream presents potential safety risks. The purpose of the analyses presented in this report is to assess the flammability of the selected working fluid in the hot exhaust gas stream stemming from a potential leak in the evaporator. Ignition delay time for cyclopentane at temperatures and pressure corresponding to direct evaporator operation was obtained for several equivalence ratios. Results of a computational fluid dynamic analysis of a pinhole leak scenario are given.

  12. Explosion protection for vehicles intended for the transport of flammable gases and liquids--an investigation into technical and operational basics.

    Science.gov (United States)

    Förster, Hans; Günther, Werner

    2009-05-30

    In Europe, the transport of flammable gases and liquids in tanks has been impacted by new developments: for example, the introduction of the vapour-balancing technique on a broad scale and the steady increase in the application of electronic components with their own power sources; furthermore, new regulatory policies like the ATEX Directives are being enforced in the European Union. With this background in mind, the present investigation aims to provide a basis for future developments of the relevant explosion protection regulations in the safety codes for the transport of dangerous goods (RID/ADR). Specifically, the concentration of gas in the air was measured under various practical conditions while tank vehicles were being loaded with flammable gases or liquids. These spot-test data were supplemented by systematic investigations at a road tanker placed in our test field. With respect to non-electrical ignition sources, a closer investigation of the effect of hot surfaces was carried out. With regard to improving the current regulations, the results of our investigation show that it would be reasonable to implement a stronger differentiation of the characteristics of the dangerous goods (gaseous/liquid, flashpoint) on the one hand and of the techniques applied (loading with and without vapour-balancing system) on the other hand. Conclusions for the further development of the current international regulations are proposed.

  13. Explosion protection for vehicles intended for the transport of flammable gases and liquids-An investigation into technical and operational basics

    International Nuclear Information System (INIS)

    Foerster, Hans; Guenther, Werner

    2009-01-01

    In Europe, the transport of flammable gases and liquids in tanks has been impacted by new developments: for example, the introduction of the vapour-balancing technique on a broad scale and the steady increase in the application of electronic components with their own power sources; furthermore, new regulatory policies like the ATEX Directives are being enforced in the European Union. With this background in mind, the present investigation aims to provide a basis for future developments of the relevant explosion protection regulations in the safety codes for the transport of dangerous goods (RID/ADR). Specifically, the concentration of gas in the air was measured under various practical conditions while tank vehicles were being loaded with flammable gases or liquids. These spot-test data were supplemented by systematic investigations at a road tanker placed in our test field. With respect to non-electrical ignition sources, a closer investigation of the effect of hot surfaces was carried out. With regard to improving the current regulations, the results of our investigation show that it would be reasonable to implement a stronger differentiation of the characteristics of the dangerous goods (gaseous/liquid, flashpoint) on the one hand and of the techniques applied (loading with and without vapour-balancing system) on the other hand. Conclusions for the further development of the current international regulations are proposed.

  14. Evaluation of mitigation strategies in Facility Group 1 double-shell flammable-gas tanks at the Hanford Site

    International Nuclear Information System (INIS)

    Unal, C.; Sadasivan, P.; Kubic, W.L.; White, J.R.

    1997-11-01

    Radioactive nuclear waste at the Hanford Site is stored in underground waste storage tanks at the site. The tanks fall into two main categories: single-shell tanks (SSTs) and double-shell tanks (DSTs). There are a total of 149 SSTs and 28 DSTs. The wastes stored in the tanks are chemically complex. They basically involve various sodium salts (mainly nitrite, nitrate, carbonates, aluminates, and hydroxides), organic compounds, heavy metals, and various radionuclides, including cesium, strontium, plutonium, and uranium. The waste is known to generate flammable gas (FG) [hydrogen, ammonia, nitrous oxide, hydrocarbons] by complex chemical reactions. The process of gas generation, retention, and release is transient. Some tanks reach a quasi-steady stage where gas generation is balanced by the release rate. Other tanks show continuous cycles of retention followed by episodic release. There currently are 25 tanks on the Flammable Gas Watch List (FGWL). The objective of this report is to evaluate possible mitigation strategies to eliminate the FG hazard. The evaluation is an engineering study of mitigation concepts for FG generation, retention, and release behavior in Tanks SY-101, AN-103, AN 104, An-105, and Aw-101. Where possible, limited quantification of the effects of mitigation strategies on the FG hazard also is considered. The results obtained from quantification efforts discussed in this report should be considered as best-estimate values. Results and conclusions of this work are intended to help in establishing methodologies in the contractor's controls selection analysis to develop necessary safety controls for closing the FG unreviewed safety question. The general performance requirements of any mitigation scheme are discussed first

  15. Program plan for evaluation and remediation of the generation and release of flammable gases in Hanford Site waste tanks

    International Nuclear Information System (INIS)

    Johnson, G.D.

    1991-08-01

    This program plan describes the activities being conducted for the resolution of the flammable gas problem that is associated with 23 high-level waste tanks at the Hanford Site. The classification of the wastes in all of these tanks is not final and some wastes may not be high-level wastes. However, until the characterization and classification is complete, all the tanks are treated as if they contain high-level waste. Of the 23 tanks, Tank 241-SY-101 (referred to as Tank 101-SY) has exhibited significant episodic releases of flammable gases (hydrogen and nitrous oxide) for the past 10 years. The major near-term focus of this program is for the understanding and stabilization of this tank. An understanding of the mechanism for gas generation and the processes for the episodic release will be obtained through sampling of the tank contents, laboratory studies, and modeling of the tank behavior. Additional information will be obtained through new and upgraded instrumentation for the tank. A number of remediation, or stabilization, concepts will be evaluated for near-term (2 to 3 years) applications to Tank 101-SY. Detailed safety assessments are required for all activities that will occur in the tank (sampling, removal of equipment, and addition of new instruments). This program plan presents a discussion of each task, provides schedules for near-term activities, and gives a summary of the expected work for fiscal years 1991, 1992, and 1993. 16 refs., 7 figs., 8 tabs

  16. Program plan for evaluation and remediation of the generation and release of flammable gases in Hanford Site waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.D. (comp.)

    1991-08-01

    This program plan describes the activities being conducted for the resolution of the flammable gas problem that is associated with 23 high-level waste tanks at the Hanford Site. The classification of the wastes in all of these tanks is not final and some wastes may not be high-level wastes. However, until the characterization and classification is complete, all the tanks are treated as if they contain high-level waste. Of the 23 tanks, Tank 241-SY-101 (referred to as Tank 101-SY) has exhibited significant episodic releases of flammable gases (hydrogen and nitrous oxide) for the past 10 years. The major near-term focus of this program is for the understanding and stabilization of this tank. An understanding of the mechanism for gas generation and the processes for the episodic release will be obtained through sampling of the tank contents, laboratory studies, and modeling of the tank behavior. Additional information will be obtained through new and upgraded instrumentation for the tank. A number of remediation, or stabilization, concepts will be evaluated for near-term (2 to 3 years) applications to Tank 101-SY. Detailed safety assessments are required for all activities that will occur in the tank (sampling, removal of equipment, and addition of new instruments). This program plan presents a discussion of each task, provides schedules for near-term activities, and gives a summary of the expected work for fiscal years 1991, 1992, and 1993. 16 refs., 7 figs., 8 tabs.

  17. Effectiveness of house dust mite acaricide tri-n-butyl tin maleate on carpets, fabrics and mattress foam: a standardization of methodology Eficácia do acaricida maleato de estanho tri-n-butílico contra ácaros de poeira em carpetes, tecidos e espuma de colchão: padronização de metodologia

    Directory of Open Access Journals (Sweden)

    Satiko Uehara

    2006-06-01

    Full Text Available The aim of this study was to determine the effectiveness of the acaricide tri-n-butyl tin maleate, industrially applied to samples of carpets, mattress foam, and fabrics used for furniture upholstery, soft toys and shoe uppers. Approximately 100 adult house dust mites of the species Dermatophagoides pteronyssinus were inoculated into a Petri dish containing the sample (a piece of carpet, mattress foam, or fabric, treated with the acaricide, randomly collected. Mite-maintenance culture medium was added on top of each sample. After one, two, three, seven and 30 days of incubation at 25 ºC and 75% relative humidity, each dish was examined using a 40X stereoscopic microscope (40X. One hundred percent acaricide effectiveness was obtained in treated materials by the end of the 30th-day postinoculation period, under optimal conditions for mite maintenance.O objetivo do presente estudo foi verificar a eficácia do acaricida maleato de estanho tri-n-butílico, aplicado industrialmente em amostras de carpetes, tecidos de revestimentos de móveis e de calçados, assim como de espumas de colchão. Aproximadamente 100 ácaros adultos da espécie Dermatophagoides pteronyssinus foram inoculados em placa de Petri contendo a amostra (pedaço de colchão, tecido ou carpete, tratada com o produto acaricida, coletados aleatoriamente. Foi acrescentado sobre a amostra, meio de cultivo para a manutenção dos ácaros. Cada placa foi examinada após 1, 2, 3, 7 e 30 dias de incubação a 25 ºC e 75% de U.R.A. (umidade relativa do ar, sob microscópio estereoscópico com 40X de aumento. O acaricida maleato de estanho tri-n-butílico apresentou 100% de eficácia acaricida após 30 dias da aplicação, em condições ótimas para a manutenção dos ácaros.

  18. Preparation, thermal and flammability properties of a novel form-stable phase change materials based on high density polyethylene/poly(ethylene-co-vinyl acetate)/organophilic montmorillonite nanocomposites/paraffin compounds

    International Nuclear Information System (INIS)

    Cai Yibing; Song Lei; He Qingliang; Yang Dandan; Hu Yuan

    2008-01-01

    The paraffin is one of important thermal energy storage materials with many desirable characteristics (i.e., high heat of fusion, varied phase change temperature, negligible supercooling, self-nucleating, no phase segregation and cheap, etc.), but has low thermal stability and flammable. Hence, a novel form-stable phase change materials (PCM) based on high density polyethylene (HDPE)/poly(ethylene-co-vinyl acetate) (EVA)/organophilic montmorillonite (OMT) nanocomposites and paraffin are prepared by twin-screw extruder technique. The structures of the HDPE-EVA/OMT nanocomposites and the form-stable PCM are evidenced by the X-ray diffraction (XRD), transmission electronic microscopy (TEM) and scanning electronic microscope (SEM). The results of XRD and TEM show that the HDPE-EVA/OMT nanocomposites form the ordered intercalated nanomorphology. The form-stable PCM consists of the paraffin, which acts as a dispersed phase change material and the HDPE-EVA/OMT nanocomposites, which acts as the supporting material. The paraffin disperses in the three-dimensional net structure formed by HDPE-EVA/OMT nanocomposites. The thermal stability, latent heat and flammability properties are characterized by thermogravimetry analysis (TGA), dynamic Fourier-transform infrared (FTIR), differential scanning calorimeter (DSC) and cone calorimeter, respectively. The TGA and dynamic FTIR analyses indicate that the incorporation of suitable amount of OMT into the form-stable PCM increase the thermal stability. The DSC results show that the latent heat of the form-stable PCM has a certain degree decrease. The cone calorimeter shows that the heat release rate (HRR) has remarkably decreases with loading of OMT in the form-stable PCM, contributing to the improved flammability properties

  19. 16 CFR 1608.6 - Reference to guaranty by Government prohibited.

    Science.gov (United States)

    2010-01-01

    ... prohibited. 1608.6 Section 1608.6 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS... guaranty by Government prohibited. No representation nor suggestion shall be made in advertising or... conforms to a flammability standard in effect under the act. ...

  20. Preparation and characterization of poly(methyl methacrylate)-clay nanocomposites via melt intercalation: Effect of organoclay on thermal, mechanical and flammability properties

    Energy Technology Data Exchange (ETDEWEB)

    Unnikrishnan, Lakshmi; Mohanty, Smita [Laboratory for Advanced Research in Polymeric Materials (LARPM), Central Institute of Plastics Engineering and Technology, Bhubaneswar 751024 (India); Nayak, Sanjay K., E-mail: drsknayak@gmail.com [Laboratory for Advanced Research in Polymeric Materials (LARPM), Central Institute of Plastics Engineering and Technology, Bhubaneswar 751024 (India); Ali, Anwar [Laboratory for Advanced Research in Polymeric Materials (LARPM), Central Institute of Plastics Engineering and Technology, Bhubaneswar 751024 (India)

    2011-05-15

    Research highlights: {yields} The present work deals with preparation and characterization of poly(methyl methacrylate) nanocomposites via melt intercalation technique. {yields} The effect of various modified nanoclays on the properties of base matrix has been investigated. {yields} It was observed that compatibilization using maleic anhydride improved the performance characteristics of PMMA/layered silicate nanocomposites. - Abstract: The PMMA nanocomposites were prepared by melt processing method. The influence of organoclay loading on extent of intercalation, thermal, mechanical and flammability properties of poly(methyl methacrylate) (PMMA)-clay nanocomposites were studied. Three different organoclay modifiers with varying hydrophobicity (single tallow vs. ditallow) were investigated. The nanocomposites were characterized by using wide angle X-ray diffraction, transmission electron microscopy, thermogravimetric analysis, differential scanning calorimetry (DSC), and tensile tests. The intercalation of polymer chain within the silicate galleries was confirmed by WAXD and TEM. Mechanical properties such as tensile modulus (E), tensile strength, percentage elongation at break and impact strength were determined for nanocomposites at various clay loadings. Overall thermal stability of nanocomposites increased by 16-17 deg. C. The enhancement in T{sub g} of nanocomposite is merely by 2-4 deg. C. The incorporation of maleic anhydride as compatibilizer further enhanced all the properties indicating improved interface between PMMA and clay. The flammability characteristics were studied by determining the rate of burning and LOI.

  1. Preparation and characterization of poly(methyl methacrylate)-clay nanocomposites via melt intercalation: Effect of organoclay on thermal, mechanical and flammability properties

    International Nuclear Information System (INIS)

    Unnikrishnan, Lakshmi; Mohanty, Smita; Nayak, Sanjay K.; Ali, Anwar

    2011-01-01

    Research highlights: → The present work deals with preparation and characterization of poly(methyl methacrylate) nanocomposites via melt intercalation technique. → The effect of various modified nanoclays on the properties of base matrix has been investigated. → It was observed that compatibilization using maleic anhydride improved the performance characteristics of PMMA/layered silicate nanocomposites. - Abstract: The PMMA nanocomposites were prepared by melt processing method. The influence of organoclay loading on extent of intercalation, thermal, mechanical and flammability properties of poly(methyl methacrylate) (PMMA)-clay nanocomposites were studied. Three different organoclay modifiers with varying hydrophobicity (single tallow vs. ditallow) were investigated. The nanocomposites were characterized by using wide angle X-ray diffraction, transmission electron microscopy, thermogravimetric analysis, differential scanning calorimetry (DSC), and tensile tests. The intercalation of polymer chain within the silicate galleries was confirmed by WAXD and TEM. Mechanical properties such as tensile modulus (E), tensile strength, percentage elongation at break and impact strength were determined for nanocomposites at various clay loadings. Overall thermal stability of nanocomposites increased by 16-17 deg. C. The enhancement in T g of nanocomposite is merely by 2-4 deg. C. The incorporation of maleic anhydride as compatibilizer further enhanced all the properties indicating improved interface between PMMA and clay. The flammability characteristics were studied by determining the rate of burning and LOI.

  2. Influence of natural or organophilic bentonite for flammable of the poly(ethylene-co-vinyl acetate); Influencia da bentonita natural ou organofilica na inflamabilidade do poli(etileno-co-acetato de vinila)

    Energy Technology Data Exchange (ETDEWEB)

    Heyder, Eduardo T.; Kloss, Juliana R.; Morita, Reinaldo Y., E-mail: yomorita1@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba,PR (Brazil). Departamento de Quimica e Biologia; Caetano, Elenice H.; Andrade, Andre Vitor C. de [Universidade Estadual de Ponta Grossa (UEPG), Ponta Grossa, PR (Brazil); Barbosa, Ronilson V. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Departamento de Quimica

    2015-07-01

    The manufacture polymeric applied in electrical sector in general use additives which act as flame retardants, for example, some borates, phosphates, and halogenated hydroxides. An alternative material for this purpose frequently reported in the literature because the flame resistance or flame retardancy is organoclay. Thus, the objective of this study is to evaluate the flammability of mixtures of EVA/natural bentonite and EVA/organoclay containing modifier as a species free of quaternary ammonium ions. The natural bentonite and organoclay were characterized by X-ray diffraction and scanning electron microscopy and materials were evaluated by X-ray diffraction and the flammability test. Regarding the combustion rate values, there was a reduction of flame propagation in EVA/natural bentonite (3.0%), showing that in this case the clay without modifier acted as a physical barrier and promoted retardant action of flame. (author)

  3. Investigation of the Extinguishing Features for Liquid Fuels and Organic Flammable Liquids Atomized by a Water Flow

    Directory of Open Access Journals (Sweden)

    Voytkov Ivan V.

    2016-01-01

    Full Text Available The processes of heat and mass transfer were investigated experimentally while moving and evaporating the atomized water flow in high-temperature combustion products of typical liquid fuels and organic flammable liquids: gasoline, kerosene, acetone, crude oil, industrial alcohol. We determined typical periods of liquid extinguishing by an atomized water flow of various dispersability. Data of the discharge of extinguishing medium corresponding to various parameters of atomization and duration of using the atomization devices was presented. It is shown that Um≈3.5 m/s is a minimal outflow velocity of droplets during moving while passing the distance of 1m in the high-temperature gas medium to stop the combustion of organic liquids.

  4. 76 FR 56304 - Hazardous Materials: Minor Editorial Corrections and Clarifications

    Science.gov (United States)

    2011-09-13

    ... of the revisions in this final rule, new entries, ``Paint related material, flammable, corrosive... are correcting the HMT by adding the entries for ``Paint related material, flammable, corrosive...-3971 (HM-226) [67 FR 53118], entitled ``Revision to Standards for Infectious Substances.'' A transition...

  5. Influence of dispersion degree of water drops on efficiency of extinguishing of flammable liquids

    Directory of Open Access Journals (Sweden)

    Korolchenko Dmitriy

    2016-01-01

    Full Text Available Depending on the size of water drops, process of fire extinguishing is focused either in a zone of combustion or on a burning liquid surface. This article considers two alternate solutions of a heat balance equation. The first solution allows us to trace decrease of temperature of a flammable liquid (FL surface to a temperature lower than fuel flash point at which combustion is stopped. And the second solution allows us to analyze decrease of burnout rate to a negligible value at which steam-air mixture becomes nonflammable. As a result of solve of a heat balance equation it was made the following conclusion: water drops which size is equal to 100 μm will completely evaporate in a zone of combustion with extent of 1 m if the flying speed of drops is even 16 mps (acc. to Stokes v = 3 mps; whereas drops of larger size will evaporate only partially.

  6. THERMAL DECOMPOSITION AND FLAMMABILITY OF ACRYLONITRILE-BUTADIENE-STYRENE/MULTI-WALLED CARBON NANOTUBES COMPOSITES

    Institute of Scientific and Technical Information of China (English)

    Li-fang Tong; Hai-yun Ma; Zheng-ping Fang

    2008-01-01

    Thermal and flammability properties of acrylonitrile-butadiene-styrene copolymer (ABS) with the addition of multi-walled carbon nanotubes (MWNTs) were studied. ABS/MWNTs composites were prepared via melt blending with the MWNTs content varied from 0.2% to 4.0% by mass. Thermogravimetry results showed that the addition of MWNTs accelerated the degradation of ABS during the whole process under air atmosphere, and both onset and maximum degradation temperature were lower than those of pure ABS. The destabilization effect of MWNTs on the thermal stability of the composites became unobvious under nitrogen, and the addition of MWNTs could improve the maximum degradation temperature. The heat release rate and time of ignition (tign) for the composites reduced greatly with the addition of MWNTs especially when the concentration of nanotubes was higher than 1.0%. The accumulation of carbon nanotubes with a network structure was observed and the char layer became thicker with increasing nanotubes concentration. Results from Raman spectra showed a higher degree of graphitization for the residues of ABS/MWNTs composites.

  7. Better backs by better beds?

    DEFF Research Database (Denmark)

    Bergholdt, Kim; Fabricius, Rasmus N; Bendix, Tom

    2008-01-01

    mattresses have a positive effect on LBP, and especially a hard mattress is commonly believed to have a positive effect. METHODS: One hundred sixty CLBP patients were randomized to 1 of 3 groups, having a mattress/bed mounted in their sleeping room for 1 month. The beds were: (1) waterbed (Akva), (2) body......-conforming foam mattress (Tempur), and (3) a hard mattress (Innovation Futon). At baseline and after 4 weeks, a blinded observer interviewed the patients on LBP levels (0-10), daily function (activities of daily living, 0-30), and on the amount of sleeping hours/night. RESULTS: Because of dropout of 19 patients...... using the probably most relevant "worst case" data. There were no relevant difference between the effects of the water bed and the foam bed. CONCLUSION: The Waterbed and foam mattress' did influence back symptoms, function and sleep more positively as apposed to the hard mattress, but the differences...

  8. Pressure Ulcer Prevention

    Science.gov (United States)

    2009-01-01

    . Summary of Findings Risk Assessment There is very low quality evidence to support the hypothesis that allocating the type of pressure-relieving equipment according to the person’s level of pressure ulcer risk statistically decreases the incidence of pressure ulcer development. Similarly, there is very low quality evidence to support the hypothesis that incorporating a risk assessment into nursing practice increases the number of preventative measures used per person and that these interventions are initiated earlier in the care continuum. Pressure Redistribution Devices There is moderate quality evidence that the use of an alternative foam mattress produces a relative risk reduction (RRR) of 69% in the incidence of pressure ulcers compared with a standard hospital mattress. The evidence does not support the superiority of one particular type of alternative foam mattress. There is very low quality evidence that the use of an alternating pressure mattress is associated with an RRR of 71% in the incidence of grade 1 or 2 pressure ulcers. Similarly, there is low quality evidence that the use of an alternating pressure mattress is associated with an RRR of 68% in the incidence of deteriorating skin changes. There is moderate quality evidence that there is a statistically nonsignificant difference in the incidence of grade 2 pressure ulcers between persons using an alternating pressure mattress and those using an alternating pressure overlay. There is moderate quality evidence that the use of an Australian sheepskin produces an RRR of 58% in the incidence of pressure ulcers grade 1 or greater. There is also evidence that sheepskins are uncomfortable to use. The Pressure Ulcer Advisory Panel noted that, in general, sheepskins are not a useful preventive intervention because they bunch up in a patient’s bed and may contribute to wound infection if not properly cleaned, and this reduces their acceptability as a preventive intervention. There is very low quality evidence that

  9. 29 CFR 1910.124 - General requirements for dipping and coating operations.

    Science.gov (United States)

    2010-07-01

    ...) The ventilation that you provide to a vapor area must keep the airborne concentration of any substance... Tanks Containing Flammable or Combustible Liquids; (iii) ACGIH's “Industrial Ventilation: A Manual of... Open-Surface Tanks, and NFPA 34-1966, Standard for Dip Tanks Containing Flammable or Combustible...

  10. What is the best support surface in prevention and treatment, as of 2012, for a patient at risk and/or suffering from pressure ulcer sore? Developing French guidelines for clinical practice.

    Science.gov (United States)

    Colin, D; Rochet, J-M; Ribinik, P; Barrois, B; Passadori, Y; Michel, J-M

    2012-10-01

    The use of support surfaces in the prevention and treatment of pressure ulcers prevention is an important part of care for a patient at risk and/or suffering from sore(s). Define which support surfaces to use in prevention and treatment of at-risk and/or pressure sore patients. A systematic review of the literature querying the several Pascal Biomed, PubMed and Cochrane Library databases from 2000 through 2010. RESULTS (GRADE A): In prevention, a structured foam mattress is more efficient than a standard hospital mattress. An alternating pressure mattress is more effective than a visco-elastic mattress limiting the occurrence heel pressure ulcers, but those that do occur are more serious. A low-air-loss bed is more efficient than a mixed pulsating air mattress in prevention of heel pressure ulcers. Some types of sheepskin can reduce sacral pressure ulcer incidence in orthopedic patients. Use of an overlay on an operating table limits the occurrence of peroperative and postoperative pressure ulcers. An air-fluidized bed improves pressure ulcer healing. The data in the literature are not always relevant and do not suffice to dictate a clinician's choices. We are compelled to recognize the methodological limitations of many studies, the lack of corporate interest in conducting such studies and the relatively small number of available trials. However, the effectiveness of some support surfaces reaches a sufficient level of evidence, especially when they are associated with postural, hydration and nutritional measures. Support surfaces are recommended in prevention and treatment of patients at risk and/or already suffering from pressure ulcer, and their use should constitute part of an overall preventive or curative strategy. Copyright © 2012. Published by Elsevier Masson SAS.

  11. Pressure Relief, Visco-Elastic Foam with Inflated Air? A Pilot Study in a Dutch Nursing Home

    Directory of Open Access Journals (Sweden)

    Martin Van Leen

    2015-02-01

    . Seventy five percent of the residents started with repositioning because there was no healing tendency of their category one PU diagnosed at the start of the pilot. Because this new type of overlay mattress resulted in an increased PU incidence, and almost standard need of repositioning with accompanied high costs, this type of overlay mattress gives no benefit above the traditional visco-elastic foam mattresses in combination with the originally used static air overlay.

  12. 78 FR 694 - Proposed Extension of Approval of Information Collection; Comment Request-Testing and...

    Science.gov (United States)

    2013-01-04

    ... ignition of mattresses, 16 CFR part 1632. The Open- Flame standard is intended to reduce unreasonable risks... may be introduced into commerce. The Office of Management and Budget (OMB) previously approved the... suppliers, and confirmation test records, if establishments choose to pool a prototype. This documentation...

  13. Factors affecting stall use for different freestall bases.

    Science.gov (United States)

    Wagner-Storch, A M; Palmer, R W; Kammel, D W

    2003-06-01

    The objective of this study was to compare stall use (stall occupancy and cow position) by barn side for factors affecting stall use. A closed circuit television system recorded stall use four times per day for a 9-mo period starting May 9, 2001. Six factors were analyzed: stall base, distance to water, stall location within stall base section, stall location within barn, inside barn temperature, and length of time cows were exposed to stall bases. Two barn sides with different stocking densities were analyzed: low (66%), with cows milked by robotic milker; and high (100%), with cows milked 2X in parlor. Six stall base types were tested: two mattresses, a waterbed, a rubber mat, concrete, and sand (high side only). The base types were grouped 3 to 7 stalls/section and randomly placed in each row. Cows spent more time in mattress-based stalls, but the highest percentage lying was in sand-based stalls. The following significant stall occupancy percentages were found: sand had the highest percentage of cows lying on the high stocking density side (69%), followed by mattress type 1 (65%) > mattress type 2 (57%) > waterbed (45%) > rubber mat (33%) > concrete (23%). Mattress type 1 had the highest percentage stalls occupied (88%), followed by mattress type 2 (84%) > sand (79%) > soft rubber mat (65%) > waterbed (62%) > concrete (39%). On the low stocking rate side, mattress type 1 had the highest percentage cows lying (45%) and occupied (59.6%), followed by mattress type 2 > waterbed > soft rubber mat > concrete. Cow lying and stalls occupied percentages were highest for stalls 1) not at the end of a section, and 2) on the outside row, and varied by base type for time cows exposed to stalls and inside barn temperature. Lying and occupied percentages were different for different mattress types. The percentage of stalls with cows standing was higher for mat and mattress-based stalls. Results show mattress type 1 and sand to be superior and rubber mats and concrete inferior

  14. 16 CFR 1019.1 - Purpose, applicability, and exemptions.

    Science.gov (United States)

    2010-01-01

    ... misbranded hazardous substance or a banned hazardous substance within the meaning of sections 2(p) and 2(q) of the Federal Hazardous Substances Act (15 U.S.C. 1261); or (3) A fabric or related material or an... conform with an applicable flammability standard or regulations issued under section 4 of the Flammable...

  15. 16 CFR 1611.37 - Reasonable and representative tests under section 8 of the Act.

    Science.gov (United States)

    2010-01-01

    ... FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations... textile fabric weighing less than two ounces per square yard, such fabric exhibits a burning time of 3.5... fabric ignites but the flame is extinguished before the stop cord is burned, such test may suffice for...

  16. Standard-B Hydrogen Monitoring System, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1995-01-01

    During most of the year, it is assumed that the vapor in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gases to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gases from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. This document describes the design of the Standard-B Hydrogen Monitoring System, (SHMS) and its components as it differs from the original SHMS. The differences are derived from changes made to improve the system performance but not implemented in all the installed enclosures

  17. The deforestation story: testing for anthropogenic origins of Africa's flammable grassy biomes.

    Science.gov (United States)

    Bond, William; Zaloumis, Nicholas P

    2016-06-05

    Africa has the most extensive C4 grassy biomes of any continent. They are highly flammable accounting for greater than 70% of the world's burnt area. Much of Africa's savannas and grasslands occur in climates warm enough and wet enough to support closed forests. The combination of open grassy systems and the frequent fires they support have long been interpreted as anthropogenic artefacts caused by humans igniting frequent fires. True grasslands, it was believed, would be restricted to climates too dry or too cold to support closed woody vegetation. The idea that higher-rainfall savannas are anthropogenic and that fires are of human origin has led to initiatives to 'reforest' Africa's open grassy systems paid for by carbon credits under the assumption that the net effect of converting these system to forests would sequester carbon, reduce greenhouse gases and mitigate global warming. This paper reviews evidence for the antiquity of African grassy ecosystems and for the fires that they sustain. Africa's grassy biomes and the fires that maintain them are ancient and there is no support for the idea that humans caused large-scale deforestation. Indicators of old-growth grasslands are described. These can help distinguish secondary grasslands suitable for reforestation from ancient grasslands that should not be afforested.This article is part of the themed issue 'The interaction of fire and mankind'. © 2016 The Author(s).

  18. 77 FR 70895 - New Marking Standards for Parcels Containing Hazardous Materials

    Science.gov (United States)

    2012-11-28

    ... dimension of each side must be 100 mm (3.94 inches), unless the package size requires a reduced size marking... third and fourth sentences of 10.12.2 as follows:] * * * Flammable gases in Division 2.1 are prohibited...

  19. Experimental investigation of n-butanol/diesel fuel blends and n-butanol fumigation – Evaluation of engine performance, exhaust emissions, heat release and flammability analysis

    International Nuclear Information System (INIS)

    Şahin, Zehra; Durgun, Orhan; Aksu, Orhan N.

    2015-01-01

    Highlights: • n-Butanol/diesel fuel blends and n-butanol fumigation investigated experimentally. • Flammability analysis of n-butanol performed. • Smoke decreases significantly for n-butanol/diesel fuel blends and n-butanol fumigation. • HC emission increases significantly for n-butanol/diesel fuel blends and n-butanol fumigation. • 2% n-Butanol/diesel fuel blend decreases slightly BSFC. - Abstract: The aim of this paper is to investigate and compare the effects of n-butanol/diesel fuel blends (nBDFBs) and n-butanol fumigation (nBF) on the engine performance and exhaust emissions in a turbocharged automobile diesel engine. Also, evaluations based on heat release and flammability analysis have been done. Experiments have been performed for various n-nBDFBs and nBF at different engine speeds and loads. For nBDFBs and nBF tests; nB2, nB4 and nB6 and nBF2, nBF4 and nBF6n-butanol percentages were selected. Here, for example nB2 and nBF2 contains 2% n-butanol and 98% diesel fuel by volume respectively. The test results showed that smoke decreases significantly by applying both of these two methods. However, decrement ratios of smoke for fumigation method are higher than that of blend method. NO x emission decreases for nB2, but it increases for nB4 and nB6 at selected engine speeds and loads. NO x emission decreases generally for nBF. For nB2 and nB4, BSFC decreases slightly but it increases for nB6. For nBF, BSFC increases at all of the test conditions. Adding n-butanol to diesel fuel becomes expensive for two methods. For nBDFBs, heat release rate (HRR) diagrams exhibit similar typical characteristic to NDF. However, for nBF, HRR shows slightly different pattern from NDF and a double peak is observed in the HRR diagram. The first peak occurs earlier than NDF and the second peak takes places later. In addition, this diagram shows that the first peak becomes larger and the second peak diminishes as n-butanol ratio is increased. Because of pilot injection of

  20. Short Communication. Comparing flammability traits among fire-stricken (low elevation) and non fire-stricken (high elevation) conifer forest species of Europe: A test of the Mutch hypothesis

    OpenAIRE

    A. P. Dimitrakopoulos; I. D. Mitsopoulos; A. Kaliva

    2013-01-01

    Aim of study. The flammability of the main coniferous forest species of Europe, divided into two groups according to their fire regime and altitudinal distribution, was tested in an effort to detect species-specific differences that may have an influence on community-wide fire regimes.Area of study. Conifer species comprising low- and high-elevation forests in Europe.Materials and Methods. The following conifer species were tested: low elevation; Pinus halepensis (Aleppo pine), Pinus brutia (...

  1. Estudio comparativo de microsutura vascular en ratas: punto simple y punto de colchonero horizontal Comparative study about vascular microsurgery on rats: classic interrupted suture versus horizontal mattress suture

    Directory of Open Access Journals (Sweden)

    C. Casado Sánchez

    2009-09-01

    Full Text Available La Microcirugía es la técnica empleada para la realización de la microanastomosis vascular. El objetivo del presente estudio es comparar dos tipos de técnicas de microsutura: los puntos simples clásicos, de empleo habitual en la microcirugía vascular, y los puntos de colchonero horizontales, no evaluados habitualmente para este tipo de cirugía. Fueron intervenidas 20 ratas albinas de la cepa Wistar (peso medio de 250 - 300 gr. bajo anestesia general; realizamos sección transversal en la arteria femoral, procediendo a su reparación microquirúrgica inmediata. Se establecieron 2 grupos de animales: en el grupo A (n=10, la microsutura se hizo mediante 6 puntos sueltos simples, y en el grupo B (n=10, empleando 3 puntos de colchonero horizontal. Comprobamos la patencia en el desclampado inmediato y tras una hora del desclampado (para ambas técnicas fue positiva en el 100% de los casos, y la hemorragia en ambos tiempos (se registró un único caso de sangrado en el postoperatorio inmediato en el grupo B, que requirió la revisión de la microsutura. El tiempo medio de ejecución de la sutura en el grupo B, 15 minutos aproximadamente, fue más corto que en el grupo A, 21 minutos aproximadamente, diferencia estadísticamente significativa (p Microsurgery is the procedure of choice for vascular microanastamoses. The objective of this study was to compare two types of suture techniques: classic interrupted suture anastomoses, commonly used for vascular anastamoses in microsurgery, and another technique using horizontal mattress sutures, rarely evaluated in this type of surgery. Twenty albino Wistar rats were operated (average weight: 250 - 300 gr. under general anaesthesia. A transverse section of the femoral artery was performed and immediately followed by an anastamoses. The animals were placed into two groups of ten. The classic 6 interrupted suture anastomoses technique was performed in group A (n = 10 and another technique using 3

  2. Flammable gas safety program. Analytical methods development: FY 1993 progress report

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Steele, R.

    1994-01-01

    This report describes the status of developing analytical methods to account for the organic constituents in Hanford waste tanks, with particular emphasis on those tanks that have been assigned to the Flammable Gas Watch List. Six samples of core segments from Tank 101-SY, obtained during the window E core sampling, have been analyzed for organic constituents. Four of the samples were from the upper region, or convective layer, of the tank and two were from the lower, nonconvective layer. The samples were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry (GC/MS). The major components detected were ethylenediaminetetraacetic acid (EDTA), nitroso-iminodiacetic acid (NIDA), nitrilotriacetic acid (NTA), citric acid (CA), succinic acid (SA), and ethylenediaminetriacetic acid (ED3A). The chelator of highest concentration was EDTA in all six samples analyzed. Liquid chromatography (LC) was used to quantitate low molecular weight acids (LMWA) including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon (TOC) in the samples analyzed was accounted for by these acids. Oxalate constituted approximately 40% of the TOC in the nonconvective layer samples. Oxalate was found to be approximately 3 to 4 times higher in concentration in the nonconvective layer than in the convective layer. During FY 1993, LC methods for analyzing LWMA, and two chelators N-(2-hydroxyethyl) ethylenediaminetriacetic acid and EDTA, were transferred to personnel in the Analytical Chemistry Laboratory and the 222-S laboratory.

  3. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.

    Science.gov (United States)

    Beimers, Lijkele; Lam, Patrick H; Murrell, George A C

    2014-10-01

    This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Prevention of pressure ulcers with a static air support surface: A systematic review.

    Science.gov (United States)

    Serraes, Brecht; van Leen, Martin; Schols, Jos; Van Hecke, Ann; Verhaeghe, Sofie; Beeckman, Dimitri

    2018-03-05

    are indications that these mattress overlays are more effective in preventing pressure ulcers compared with the use of a standard mattress or a pressure-reducing foam mattress in nursing homes and intensive care settings. However, interpretation of the evidence should be performed with caution due to the wide variety of methodological and/or reporting quality levels of the included studies. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. A novel intumescent flame retardant-functionalized graphene: Nanocomposite synthesis, characterization, and flammability properties

    International Nuclear Information System (INIS)

    Huang, Guobo; Chen, Suqing; Tang, Shouwan; Gao, Jianrong

    2012-01-01

    An intumescent flame retardant, poly(piperazine spirocyclic pentaerythritol bisphosphonate) (PPSPB), has been covalently grafted onto the surfaces of graphene oxide (GO) to obtain GO–PPSPB and according nanocomposites were prepared via solvent blending. The X-ray diffraction (XRD) and transmission electron microscopy (TEM) results show that the chemically reduced GO–PPSPB (CRG–PPSPB) can achieve better dispersion in the ethylene vinyl acetate copolymer (EVA) matrix and exfoliated EVA/CRG–PPSPB nanocomposites are formed. The results from thermogravimetric analysis (TGA) and cone calorimeter tests indicate that CRG–PPSPB improve thermal stability and reduce obviously the flammability (including peak heat release rate (PHRR), total heat release (THR), average mass loss rate (AMLR), etc.) of EVA. Compared with pure EVA resin, the PHRR of the EVA/CRG–PPSPB nanocomposites filled with 1 wt% CRG–PPSPB is reduced by about 56%. The SEM images show that a compact, dense and uniform intumescent char is formed for EVA/CRG–PPSPB nanocomposites after combustion. The functionalization of graphene by intumescent flame retardant PPSPB can improve both the dispersion of graphene sheets in the polymer matrix and flame retardancy of the nanocomposites. -- Highlights: ► Graphene oxide were modified with intumescent flame retardant PPSPB. ► EVA/CRG–PPSPB nanocomposites were prepared via solvent blending. ► CRG–PPSPB improved the flame retardancy of EVA nanocomposites.

  6. The future of the OSHA PSM standard.

    Science.gov (United States)

    Kaelin, David E

    2014-07-01

    The significance of the proposed PSM changes could be to greatly expand coverage of processes in order to include many not currently covered by the PSM regulation. New chemicals will likely be added to Appendix A, and reactive chemicals (a definition will be needed) also may be covered. What exactly will be the definition of a reactive chemical is unclear at this time, although definitions used in New Jersey in the TCPA Act may guide OSHA. It is likely that atmospheric storage of flammable liquids will be included more specifically and the exemption of these tanks eliminated. In applying RAGAGEP, sites may be required to apply the most recent codes and standards to covered processes, perhaps at the time of PHA auditing: A narrowing of the PSM exemption for retail facilities could bring many of them under the PSM regulation at some level. Process safety management practices should be applied to all facilities that store and process hazardous materials that have fire, explosion, reactivity, and toxic properties. If changes are made to the PSM regulation, many new sites will be covered and will need to formally adopt PSM as defined in the OSHA regulation. The addition of reactive chemicals to the PSM regulation will greatly expand the number of processes covered by the regulation. Keeping up with the most current codes, standards, and legislative changes is a daunting task that may require the support of specialists. The results of the proposed legislation will be an increase in the level of process safety excellence throughout the chemical industries.

  7. Analyses in Support of Risk-Informed Natural Gas Vehicle Maintenance Facility Codes and Standards: Phase II.

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, Myra L.; LaFleur, Chris Bensdotter; Muna, Alice Baca; Ehrhart, Brian David

    2018-03-01

    Safety standards development for maintenance facilities of liquid and compressed natural gas fueled vehicles is required to ensure proper facility design and operating procedures. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase II work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest using risk ranking. Detailed simulations and modeling were performed to estimate the location and behavior of natural gas releases based on these scenarios. Specific code conflicts were identified, and ineffective code requirements were highlighted and resolutions proposed. These include ventilation rate basis on area or volume, as well as a ceiling offset which seems ineffective at protecting against flammable gas concentrations. ACKNOWLEDGEMENTS The authors gratefully acknowledge Bill Houf (SNL -- Retired) for his assistance with the set-up and post-processing of the numerical simulations. The authors also acknowledge Doug Horne (retired) for his helpful discussions. We would also like to acknowledge the support from the Clean Cities program of DOE's Vehicle Technology Office.

  8. From Fireproof Desert to Flammable Grassland: Buffelgrass Invasion in the Sonoran Desert

    Science.gov (United States)

    Betancourt, J. L.

    2007-12-01

    Only a few decades ago, the Sonoran Desert of northwestern Mexico and southern Arizona was considered mostly fireproof, a case of not enough fine fuel to connect the dominant shrubs and cacti. This has changed with invasions by non-native, winter annual and summer-flower perennial grasses that are rapidly transforming fireproof desert into flammable grassland. Of particular concern is buffelgrass, Pennisetum ciliare, a fire-prone and invasive African perennial grass that has already converted millions of hectares across Sonora since the mid-1960s and has made quick headway in southern and central Arizona beginning in the 1980s. Near Tucson and Phoenix, AZ, buffelgrass invasion is proceeding exponentially, with population expansion (and the costs of mitigation) more than doubling every year. As this conversion progresses, there will be increased fire risks, lost tourist revenue, diminished property values, insurmountable setbacks to conservation efforts, and the threat of large ignition fronts in desert valleys routinely spreading into the mountains. Although somewhat belated, an integrated, multi-jurisdictional effort is being organized to reduce ecological and economic impacts. My presentation will summarize the history and context of buffelgrass introduction and invasion, the disconnect in attitudes and policies across state and international boundaries, ongoing management efforts, the role of science and responsibilities of scientists, accelerated spread with changing climate, and impacts to regional ecosystems and economies. This narrative may serve as a template for other semi-arid lands where buffelgrass and similar grasses have become invasive, including Australia, South America, and many islands in the Pacific Ocean (including Hawaii), Indian Ocean, and Caribbean Sea.

  9. Pressure ulcer prevention and healing using alternating pressure mattress at home: the PARESTRY project.

    Science.gov (United States)

    Meaume, S; Marty, M

    2015-08-01

    Specialised pressure-relieving supports reduce or relieve the interface pressure between the skin and the support surface. The comparative effectiveness of dynamic support surfaces is debated. The aim of this study is to examine the impact of using an alternating pressure air mattress (APAM) on pressure ulcer (PU) incidence in patients receiving home-based care. A second aim was to determine the level of patient/family satisfaction with comfort and gain the views of the care team that used the APAM. The PARESTRY study was a prospective observational study conducted in patients with a high risk of PUs (Braden score prevention groups consisted of patients with no PU at baseline who were in bed for at least 20 hours a day. Patients at baseline with a category 3 or 4 PU or a category 1 or 2 PU in association with poor general health or end-of-life status were included in the secondary prevention group. All patients were laid on an APAM. The primary end point was the % of patients with a worsening skin condition in the pressure area (heel, sacrum, ischium) at day 90 or at the end of the study. The primary analysis was done on the full analysis set (patients included with at least a second assessment), using the last observation carried forward technique to handle missing data, at day 90. A 95% confidence interval was calculated. Analysis was performed on 92 patients (30 in primary prevention and 62 in secondary prevention). The average time spent in bed was 22.7 (SD 2.7) hours a day and 22.6 (SD 2.2) hours in the primary and secondary prevention groups, respectively. At baseline, in the secondary group, 77% of patients had a sacral PU, 63% a heel PU, 8% an ischial tuberosity PU and 45% a PU in another area, a number of patients having multiple PUs. In the primary prevention group, 63% (19/30) of patients dropped out of the study (5 were hospitalised, 9 died, 5 other causes). In the secondary prevention group, 61% (38/62) dropped out (7 were hospitalised, 23 died, 8

  10. Novel synthesis of magnesium hydroxide nanoparticles modified with organic phosphate and their effect on the flammability of acrylonitrile-butadiene styrene nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Attia, Nour F., E-mail: drnour2005@yahoo.com [Fire Protection Laboratory, Chemistry Division, National Institute of Standards, 136, Giza 12211 (Egypt); Goda, Emad S.; Nour, M.A. [Fire Protection Laboratory, Chemistry Division, National Institute of Standards, 136, Giza 12211 (Egypt); Sabaa, M.W. [Chemistry Department, Faculty of Science, Cairo University, NahdetMisr Street, Giza 12613 (Egypt); Hassan, M.A., E-mail: Mohamed_a_hassan@hotmail.com [Fire Protection Laboratory, Chemistry Division, National Institute of Standards, 136, Giza 12211 (Egypt)

    2015-11-15

    New and facile method for the synthesis and modification of magnesium hydroxide nanoparticles has been developed. The organic phosphate was used to facilitate the synthesis and wrapping of magnesium hydroxide nanoparticles with organic phosphate shell. The size of the nanoparticles wrapped with phosphate has an average diameter range from 46 to 125 nm. The preparation method has governed the nanoparticles diameter based on reaction time. Thermal stability and morphological properties of the new nanoparticles coated phosphates were investigated. The developed magnesium hydroxide nanoparticles-organic phosphate achieved a very good compatibility when dispersed in acrylonitrile-butadiene styrene polymer (ABS) produced dispersed nanocomposites. The flammability and thermal properties of the new polymer nanocomposites were studied. The rate of burning of the nanocomposites was reduced to 9.8 mm/min compared to 15, 21.9 and 42.5 mm/min for polymer-conventional magnesium hydroxide composite, polymer-conventional magnesium hydroxide-organic phosphate composite and virgin polymer, respectively. The peak heat release rate (PHRR) and total heat release (THR) of the new nanocomposites were recorded as 243.4 kW/m{sup 2} and 19.2 MJ/m{sup 2}, respectively, achieved 71% reduction for PHRR and 55% for THR. The synergism between magnesium hydroxide nanoparticles and organic phosphates shell was also studied. The developed nanoparticles suppressed the emission of toxic gases. The different materials were characterized using thermal gravimetric analysis, fourier transform infrared spectroscopy, transmission electron microscopy. The flammability properties were evaluated using UL94 horizontal method and cone calorimeter. The dispersion of magnesium hydroxide nanoparticles-organic phosphate in ABS was studied using scanning electron microscope. - Highlights: • Novel and facile nanoparticles synthesis and modification have developed. • Magnesium hydroxide nanoparticles size has

  11. Permeability and flammability study of composite sandwich structures for cryogenic applications

    Science.gov (United States)

    Bubacz, Monika

    Fiber reinforced plastics offer advantageous specific strength and stiffness compared to metals and has been identified as candidates for the reusable space transportation systems primary structures including cryogenic tanks. A number of carbon and aramid fiber reinforced plastics have been considered for the liquid hydrogen tanks. Materials selection is based upon mechanical properties and containment performance (long and short term) and upon manufacturing considerations. The liquid hydrogen tank carries shear, torque, end load, and bending moment due to gusts, maneuver, take-off, landing, lift, drag, and fuel sloshing. The tank is pressurized to about 1.5 atmosphere (14.6psi or 0.1 MPa) differential pressure and on ascent maintains the liquid hydrogen at a temperature of 20K. The objective of the research effort into lay the foundation for developing the technology required for reliable prediction of the effects of various design, manufacturing, and service parameters on the susceptibility of composite tanks to develop excessive permeability to cryogenic fuels. Efforts will be expended on developing the materials and structural concepts for the cryogenic tanks that can meet the functional requirements. This will include consideration for double wall composite sandwich structures, with inner wall to meet the cryogenic requirements. The structure will incorporate nanoparticles for properties modifications and developing barriers. The main effort will be extended to tank wall's internal skin design. The main requirements for internal composite stack are: (1) introduction of barrier film (e.g. honeycomb material paper sheet) to reduce the wall permeability to hydrogen, (2) introduction of nanoparticles into laminate resin to prevent micro-cracking or crack propagation. There is a need to characterize and analyze composite sandwich structural damage due to burning and explosion. Better understanding of the flammability and blast resistance of the composite structures

  12. Independent design review report for truck number 1 modifications for flammable gas tanks

    International Nuclear Information System (INIS)

    Wilson, G.W.

    1997-01-01

    The East and West Tank Farm Standing Order 97-01 requires that the PMST be modified to include purging of the enclosed space underneath the shielded receiver weather cover per National Fire Protection Association (NFPA) 496, Purged and Pressurized Enclosures for Electrical Equipment. The Standing Order also requires that the PMST be modified by replacing the existing electrical remote latch (RLU) unit with a mechanical remote latch unit. As the mechanical remote latch unit was exactly like the RLU installed on the Rotary Mode Core Sampler Trucks (RMCST) and the design for the RMCST went through formal design review, replacing the RLU was done utilizing informal design verification and was completed per work package ES-97-0028. As the weather cover purge was similar to the design for the RMCSTS, this design was reviewed using the independent review method with multiple independent reviewers. A function design criteria (WHC-SD-WM-FDC-048, Functional Design Criteria for Core Sampling in Flammable Gas Watch List Tanks) provided the criteria for the modifications. The review consisted of distributing the design review package to the reviewers and collecting and dispositioning the RCR comments. The review package included the ECNs for review, the Design Compliance Matrix, copies of all drawings affected, and copies of outstanding ECNs against these drawings. A final meeting was held to ensure that all reviewers were aware of the changes to ECNs from incorporation of RCR comments

  13. 75 FR 72944 - Third Party Testing for Certain Children's Products; Mattresses, Mattress Pads, and/or Mattress...

    Science.gov (United States)

    2010-11-29

    ...: Revisions to Terms of Acceptance of Children's Product Certifications Based on Third Party Conformity... under which it will accept certifications for children's products based on third party conformity..., requires that certification be based on testing of sufficient samples of the product, or samples that are...

  14. Evaluation of the generation and release of flammable gases in tank 241-SY-101

    Energy Technology Data Exchange (ETDEWEB)

    Babad, H.; Johnson, G.D.; Lechelt, J.A.; Reynolds, D.A. (Westinghouse Hanford Co., Richland, WA (United States)); Pederson, L.R.; Strachan, D.M. (Pacific Northwest Lab., Richland, WA (United States)); Meisel, D.; Jonah, C. (Argonne National Lab., IL (United States)); Ashby, E.C. (Georgia Inst. of Tech., Atlanta, GA (United States))

    1991-11-01

    Tank 241-SY-101 is a double shell, high-level waste tank located in the 200 West Area of the Hanford Site. This tank contains about 1 million gallons of waste that was concentrated at the 242-S Evaporator. Shortly after the waste was put in the tank, the waste began to expand because the generation of gases. In 1990 this tank was declared to have an unreviewed safety question because of the periodic release of hydrogen and nitrous oxide. A safety program was established to conduct a characterization of the waste and vented gases and to determine an effective means to prevent the accumulation of flammable gases in the tank dome space and ventilation system. Results of the expanded characterization conducted in fiscal year 1991 are presented. The use of gas chromatographs, mass spectrometers, and hydrogen-specific monitors provided a greater understanding of the vented gases. Additional instrumentation placed in the tank also helped to provide more detailed information on tank temperatures, gas pressure, and gas flow rates. An extensive laboratory study involving the Westinghouse Hanford Company, Pacific Northwest Laboratory, Argonne National Laboratory, and the Georgia Institute of Technology was initiated for the purpose of determining the mechanisms responsible for the generation of various gases. These studies evaluate both radiolytic and thermochemical processes. Results of the first series of experiments are described.

  15. A bacteriological study of hospital beds before and after disinfection with phenolic disinfectant

    Directory of Open Access Journals (Sweden)

    Andrade Denise de

    2000-01-01

    Full Text Available In hospitals, one of the ways to control microbial contamination is by disinfecting the furniture used by patients. This study's main objective was to evaluate the microbiological condition of hospital mattresses before and after such disinfection, in order to identify bacteria that are epidemiologically important in nosocomial infection, such as Staphylococcus aureus and Pseudomonas aeruginosa. RODAC plates with two different culture media were used to collect specimens. Patient beds were selected according to previously established criteria, and surface areas on the mattresses were chosen at random. From the total of 1 040 plate cultures from 52 mattresses, positive results were obtained from 500 of them (48.1%, 263 before disinfection and 237 after disinfection. Considering the selectivity of the culture media, the positivity rate was high. There were high prevalences of S. aureus both before and after mattress disinfection. The study results suggest that the usual disinfection procedures, instead of diminishing the number of microbes, merely displace them from one part of the mattress to another, and the number of microorganisms remains the same.

  16. A bacteriological study of hospital beds before and after disinfection with phenolic disinfectant

    Directory of Open Access Journals (Sweden)

    Denise de Andrade

    2000-03-01

    Full Text Available In hospitals, one of the ways to control microbial contamination is by disinfecting the furniture used by patients. This study's main objective was to evaluate the microbiological condition of hospital mattresses before and after such disinfection, in order to identify bacteria that are epidemiologically important in nosocomial infection, such as Staphylococcus aureus and Pseudomonas aeruginosa. RODAC plates with two different culture media were used to collect specimens. Patient beds were selected according to previously established criteria, and surface areas on the mattresses were chosen at random. From the total of 1 040 plate cultures from 52 mattresses, positive results were obtained from 500 of them (48.1%, 263 before disinfection and 237 after disinfection. Considering the selectivity of the culture media, the positivity rate was high. There were high prevalences of S. aureus both before and after mattress disinfection. The study results suggest that the usual disinfection procedures, instead of diminishing the number of microbes, merely displace them from one part of the mattress to another, and the number of microorganisms remains the same.

  17. Behavioral observation differentiates the effects of an intervention to promote sleep in premature infants: a pilot study.

    Science.gov (United States)

    Lacina, Linda; Casper, Tammy; Dixon, Melodie; Harmeyer, Joann; Haberman, Beth; Alberts, Jeffrey R; Simakajornboon, Narong; Visscher, Marty O

    2015-02-01

    Sleep and ongoing cycling of sleep states are required for neurosensory processing, learning, and brain plasticity. Many aspects of neonatal intensive care environments such as handling for routine and invasive procedures, bright lighting, and noise can create stress, disrupt behavior, and interfere with sleep in prematurely born infants. The study empirically investigated whether a 30-minute observation of infant sleep states and behavior could differentiate an intervention to promote sleep in premature infants with feeding difficulties relative to conventional care (standard positioning, standard crib mattress [SP]). We included an intervention to determine the ability of the method to discriminate treatments and generate a benchmark for future improvements. The intervention, a conformational positioner (CP), is contoured around the infant to provide customized containment and boundaries. To more fully verify the 30-minute observational sleep results, standard polysomnography was conducted simultaneously and sleep outcomes for the 2 modalities were compared. In a randomized crossover clinical trial, 25 infants, 31.5 ± 0.6 weeks' gestational age and 38.4 ± 0.6 weeks at the study, with gastrointestinal conditions or general feeding difficulties used each intervention during an overnight neonatal intensive care unit sleep study. Infant sleep states and behaviors were observed during two 30-minute periods--that is, on the positioner and mattress--using the naturalistic observation of newborn behavior. Two certified developmental care nurses assessed sleep state, self-regulatory, and stress behaviors during 2-minute intervals and summed over 30 minutes. Sleep characteristics from standard polysomnography were measured at the time of behavior observations. Infants on CP spent significantly less time in alert, active awake, or crying states by observation compared with SP. Surgical subjects spent more time awake, active awake, or crying and displayed a higher number

  18. Study of the radiation effect on the mechanical properties of flammability and the glow wire of polyamide 6.6 with and without fiber glass reinforcement

    International Nuclear Information System (INIS)

    Ferro, Waldir Pedro; Silva, Leonardo Gondim de Andrade e

    2002-01-01

    The Automotive, Electric and Electronic Component Industry, more and more employ the Engineering Plastic as a viable alternative for the reduction of costs and increase of productivity without loss of quality. Polyamide 6.6 is an Engineering Plastic with distinguished role on this category of polymers due to its high thermal and chemical resistances and strength. The aim of this work is to present the results of Tensile Strength, Flexural Strength and Izod Notched Impact Strength as well as thermal experiments of Flammability (Automotive and Electronic Components Industry) and of Glow Wire (Electric Components Industry) of Polyamide 6.6 with or without Fiber Glass reinforcement, irradiated by Electron Beams in different doses. (author)

  19. A safety assessment of rotary mode core sampling in flammable gas single shell tanks: Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Raymond, R.E.

    1996-04-15

    This safety assessment (SA) addresses each of the required elements associated with the installation, operation, and removal of a rotary-mode core sampling (RMCS) device in flammable-gas single-shell tanks (SSTs). The RMCS operations are needed in order to retrieve waste samples from SSTs with hard layers of waste for which push-mode sampling is not adequate for sampling. In this SA, potential hazards associated with the proposed action were identified and evaluated systematically. Several potential accident cases that could result in radiological or toxicological gas releases were identified and analyzed and their consequences assessed. Administrative controls, procedures and design changes required to eliminate or reduce the potential of hazards were identified. The accidents were analyzed under nine categories, four of which were burn scenarios. In SSTS, burn accidents result in unacceptable consequences because of a potential dome collapse. The accidents in which an aboveground burn propagates into the dome space were shown to be in the ``beyond extremely unlikely`` frequency category. Given the unknown nature of the gas-release behavior in the SSTS, a number of design changes and administrative controls were implemented to achieve these low frequencies. Likewise, drill string fires and dome space fires were shown to be very low frequency accidents by taking credit for the design changes, controls, and available experimental and analytical data. However, a number of Bureau of Mines (BOM) tests must be completed before some of the burn accidents can be dismissed with high confidence. Under the category of waste fires, the possibility of igniting the entrapped gases and the waste itself were analyzed. Experiments are being conducted at the BOM to demonstrate that the drill bit is not capable of igniting the trapped gas in the waste. Laboratory testing and thermal analysis demonstrated that, under normal operating conditions, the drill bit will not create high

  20. A safety assessment of rotary mode core sampling in flammable gas single shell tanks: Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    Raymond, R.E.

    1996-01-01

    This safety assessment (SA) addresses each of the required elements associated with the installation, operation, and removal of a rotary-mode core sampling (RMCS) device in flammable-gas single-shell tanks (SSTs). The RMCS operations are needed in order to retrieve waste samples from SSTs with hard layers of waste for which push-mode sampling is not adequate for sampling. In this SA, potential hazards associated with the proposed action were identified and evaluated systematically. Several potential accident cases that could result in radiological or toxicological gas releases were identified and analyzed and their consequences assessed. Administrative controls, procedures and design changes required to eliminate or reduce the potential of hazards were identified. The accidents were analyzed under nine categories, four of which were burn scenarios. In SSTS, burn accidents result in unacceptable consequences because of a potential dome collapse. The accidents in which an aboveground burn propagates into the dome space were shown to be in the ''beyond extremely unlikely'' frequency category. Given the unknown nature of the gas-release behavior in the SSTS, a number of design changes and administrative controls were implemented to achieve these low frequencies. Likewise, drill string fires and dome space fires were shown to be very low frequency accidents by taking credit for the design changes, controls, and available experimental and analytical data. However, a number of Bureau of Mines (BOM) tests must be completed before some of the burn accidents can be dismissed with high confidence. Under the category of waste fires, the possibility of igniting the entrapped gases and the waste itself were analyzed. Experiments are being conducted at the BOM to demonstrate that the drill bit is not capable of igniting the trapped gas in the waste. Laboratory testing and thermal analysis demonstrated that, under normal operating conditions, the drill bit will not create high

  1. Self-propagating high-temperature synthesis flammable range and dominant parameters for synthesizing several ceramics and intermetallic compounds under heat-loss condition

    International Nuclear Information System (INIS)

    Makino, Atsushi

    1996-01-01

    Extensive comparisons have been conducted between experimental and theoretical results for the nonadiabatic self-propagating high-temperature synthesis combustion characteristics of many solid-solid systems subjected to volumetric heat loss. The nonadiabatic flame propagation theory--which describes the premixed mode of bulk flame propagation supported by the nonpremixed reaction of dispersed nonmetal (or higher-melting point metal) particles in the liquid metal, with finite-rate reaction at the particle surface and temperature-sensitive Arrhenius-type condensed-phase mass diffusivity--is used to compare with experimental results with heat loss. Systems examined are ceramics (TiC, TiB 2 , and ZrB 2 ) and intermetallic compounds (NiAl, TiCo, and TiNi). By using a consistent set of physicochemical parameters for these systems, satisfactory quantitative agreement is demonstrated for the flammable range (defined in terms of the mixture ratio, degree of dilution, particle size, and/or compact diameter)

  2. How to Find Bed Bugs

    Science.gov (United States)

    Find and correctly identify an infestation early before it becomes widespread. Look for rusty or reddish stains and pinpoint dark spots on bed sheets or mattresses, and search for bugs near the piping, seams and tags of the mattress and box spring.

  3. Quantification of nanoparticle release from polymer nanocomposite coatings due to environmental stressing.

    Science.gov (United States)

    Kim, Yeon Seok; Davis, Rick; Uddin, Nasir; Nyden, Marc; Rabb, Savelas A

    2016-01-01

    Certain engineered nanoparticles (ENP) reduce the flammability of components used in soft furnishings (mattresses and upholstered furniture). However, because of the ENP's small size and ability to interact with biological molecules, these fire retardant ENPs may pose a health and environmental risks, if they are released sometime during the life cycle of the soft furnishing. Quantifying the released amount of these ENPs under normal end-use circumstances provides a basis for assessing their potential health and environmental impact. In this article, we report on efforts to identify suitable methodologies for quantifying the release of carbon nanofibers, carbon nanotubes, and sodium montmorillonites from coatings applied to the surfaces of barrier fabric and polyurethane foam. The ENPs released in simulated chewing and mechanical stressing experiments were collected in aqueous solution and quantified using Ultraviolet-Visible and inductively coupled plasma-optical emission spectroscopy. The microstructures of the released ENPs were characterized using scanning electron microscopy. The reported methodology and results provide important milestones to estimate the impact and toxicity of the ENP release during the life cycle of the nanocomposites. To our knowledge, this is the first study of ENP release from the soft furnishing coating, something that can be important application area for fire safety.

  4. 49 CFR 571.302 - Standard No. 302; Flammability of interior materials.

    Science.gov (United States)

    2010-10-01

    ... frame. S5.1.4A bunsen burner with a tube of 10 mm inside diameter is used. The gas adjusting valve is set to provide a flame, with the tube vertical, of 38 mm in height. The air inlet to the burner is... seven to eight smooth, rounded teeth per 25 mm. S5.3Procedure. (a) Mount the specimen so that both sides...

  5. Contribution to internal pressure and flammable gas concentration in RAM [radioactive material] transport packages

    International Nuclear Information System (INIS)

    Warrant, M.M.; Brown, N.

    1989-01-01

    Various facilities in the US generate wastes contaminated with transuranic (TRU) isotopes (such as plutonium and americium) that decay primarily by emission of alpha particles. The waste materials consist of a wide variety of commercially available plastics, paper, cloth, and rubber; concreted or sludge wastes containing water; and metals, glass, and other solid inorganic materials. TRU wastes that have surface dose rates of 200 mrem/hr or less are typically packaged in plastic bags placed inside metal drums or boxes that are vented through high efficiency particulate air (HEPA) filters. These wastes are to be transported from waste generation or storage sites to the Waste Isolation Pilot Plant (WIPP) in the TRUPACT-II, a Type B package. Radiolysis of organic wastes or packaging materials, or wastes containing water generates gas which may be flammable or simply contribute to the internal pressure of the radioactive material (RAM) transport package. This paper discusses the factors that affect the amount and composition of this gas, and summarizes maximum radiolytic G values (number of molecules produced per 100 eV absorbed energy) found in the technical literature for many common materials. These G values can be used to determine the combination of payload materials and decay heats that are safe for transport. G values are established for categories of materials, based on chemical functional groups. It is also shown using transient diffusion and quasi-equilibrium statistical mechanics methods that hydrogen, if generated, will not stratify at the top of the transport package void space. 9 refs., 1 tab

  6. Experimental study of hydrogen combustion in a flammable atmosphere in presence of water drops

    International Nuclear Information System (INIS)

    Cheikhravat, Homan

    2009-01-01

    This thesis is part of safety studies on Pressurized Water Reactors for nuclear power plants. Scenarios including a release of hydrogen predict to trigger spraying in order to reduce the pressure and collect the aerosols towards the bottom. However spraying involves lowering the temperature and, consequently, the content of water vapor initially sufficient to render the atmosphere inert. The purpose of this thesis is to study the de-inerting conditions of premixed hydrogen / air / water vapor in presence of fogs and then to analyze the interaction between the water spray and the flame which can initially be laminar or turbulent. For this purpose two facilities have been designed: a spherical one of 56 L with central ignition that can be heated to 200 C and a large one optimised for flame acceleration (ENACCEF). With these tools have been determined the flammability limits of H 2 /air/water vapor as a function of pressure and temperature, the behavior of flames close to the limits, the effect of sprinkling on de-inerting and finally the interaction between the flame front and the droplets considering different mean droplets sizes. The influence of a hydrogen concentration gradient on the acceleration criterion and the role of sprinkling on the propagation of a turbulent flame have also been studied. It appears that the spray can cause not only de-inerting but also be ineffective in extinguishing the flame and, in some cases, can even increase the turbulence rate and consequently the flame acceleration process. (author)

  7. Ultrasonic irradiation-promoted one-pot synthesis of CH3NH3PbBr3 quantum dots without using flammable CH3NH2 precursor

    Science.gov (United States)

    Jiang, Han; Wang, Chunlei; Lv, Changgui; Xu, Shuhong; Zhu, Li; Zhang, Ruohu; Cui, Yiping

    2017-02-01

    At present, the CH3NH3PbBr3 quantum dots (QDs) reported in the literature usually contain two synthesis steps: the initial preparation of CH3NH3Br via the reaction of flammable CH3NH2 and HBr, together with the subsequent formation of CH3NH3PbBr3 QDs. To avoid the use of dangerous CH3NH2, this work develops a novel one-pot method for synthesizing CH3NH3PbBr3 QDs using safe and commercially available reactants (CH3NH3Cl, KBr and PbCl2). It is found that ultrasonic treatment plays a key role during the synthesis of CH3NH3PbBr3 QDs. Without ultrasonic irradiation, it is not possible to synthesize CH3NH3PbBr3 QDs under heating or vigorous stirring. Aliquots of samples taken at different ultrasonic irradiation time intervals show a time-dependent redshift in the emission wavelength. This suggests the formation of CH3NH3PbCl3 QDs first, followed by the formation of CH3NH3PbBr3 QDs through ultrasonically promoted halide exchange. Moreover, mixed CH3NH3PbCl x Br3-x QDs with a tunable emission wavelength can also be prepared through this one-pot method by controlling the ultrasonic irradiation time. In comparison to the previous two-step method, the current one-pot method is simpler, less time-consuming and does not use flammable CH3NH2. The as-prepared CH3NH3PbBr3 QDs show a comparable photoluminescence (PL) quantum yield (QY) to that of the literature. What is more, the ultrasonic time-controlled emission wavelength of CH3NH3PbCl x Br3-x QDs also provides an alternative way of tuning QD emission to the traditional way of controlling the halide ratios.

  8. Pressure relieving support surfaces (PRESSURE) trial: cost effectiveness analysis.

    Science.gov (United States)

    Iglesias, Cynthia; Nixon, Jane; Cranny, Gillian; Nelson, E Andrea; Hawkins, Kim; Phillips, Angela; Torgerson, David; Mason, Su; Cullum, Nicky

    2006-06-17

    To assess the cost effectiveness of alternating pressure mattresses compared with alternating pressure overlays for the prevention of pressure ulcers in patients admitted to hospital. Cost effectiveness analysis carried out alongside the pressure relieving support surfaces (PRESSURE) trial; a multicentre UK based pragmatic randomised controlled trial. 11 hospitals in six UK NHS trusts. Intention to treat population comprising 1971 participants. Kaplan Meier estimates of restricted mean time to development of pressure ulcers and total costs for treatment in hospital. Alternating pressure mattresses were associated with lower overall costs (283.6 pounds sterling per patient on average, 95% confidence interval--377.59 pounds sterling to 976.79 pounds sterling) mainly due to reduced length of stay in hospital, and greater benefits (a delay in time to ulceration of 10.64 days on average,--24.40 to 3.09). The differences in health benefits and total costs for hospital stay between alternating pressure mattresses and alternating pressure overlays were not statistically significant; however, a cost effectiveness acceptability curve indicated that on average alternating pressure mattresses compared with alternating pressure overlays were associated with an 80% probability of being cost saving. Alternating pressure mattresses for the prevention of pressure ulcers are more likely to be cost effective and are more acceptable to patients than alternating pressure overlays.

  9. 78 FR 46952 - Relief-Mart, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Science.gov (United States)

    2013-08-02

    ... representations that a memory foam mattress lacks the common smell associated with memory foam to mean that the... involves respondent's marketing and sale of memory foam mattresses. According to the FTC's complaint... off-gassing, and lack the odors commonly associated with memory foam. The complaint alleges that...

  10. Decubitus prophylaxis

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Jensen, O; Kvorning, S A

    1983-01-01

    Six hundred patients at risk for pressure sores were randomized in either a control group or one of two experimental groups placed on alternating-pressure air-mattresses and water-mattresses. The groups remained comparable throughout the 10-day study period. Twenty-one patients from the control...

  11. Avaliação da presença de Staphylococcus aureus nos leitos do Centro de Terapia Intensiva do Hospital Escola da Faculdade de Medicina do Triângulo Mineiro, em relação à posição no colchão antes e após a limpeza Evaluation of presence of Staphylococcus aureus on the beds of Hospital Escola's Intensive Care Unit, concerning the position on the mattress, before and after cleaning

    Directory of Open Access Journals (Sweden)

    Guilhermo Justino Mundim

    2003-12-01

    Full Text Available Através de meios de cultura, foi pesquisada a posição de colônias de Staphylococcus aureus em colchões, visando avaliar a eficácia do procedimento de limpeza e desinfecção dos leitos do Hospital Escola da Faculdade de Medicina do Triângulo Mineiro (Uberaba. Foram analisadas amostras de 50 colchões no período de 22 de outubro de 2000 a 16 de janeiro de 2001. As amostras foram coletadas e semeadas, pela técnica de esgotamento, em dois meios de cultivo (ágar sangue e manitol com posterior realização de provas de catalase e coagulase . Na análise estatística, foram utilizados os testes não paramétricos Mann-Whitney, Kruswkal- Wallis e Wilcoxon Matched Pairs Test com nível de significância p 0,05. Os resultados apontam e alertam para falhas no procedimento de limpeza e desinfecção dos leitos hospitalares por nós estudados.By means of culture medium, it was researched the position of the colony of Staphylococcus aureus on the mattress, to evaluate the efficciuoness of the methods of cleaning and disinfection of the river bed in the Faculdade de Medicina do Triângulo Mineiro's School Hospital (Uberaba. It were evaluated fifty mattresses on the period of October 22th (2000 to January 16th (2001. The samples were collected and grown, the exhaustion techinique draining, on two different nutrient bases (blood agar and mannitol salt agar followed by catalase and coagulase tests. For the statistical analysis, were used non-parametrics tests Mann-Whitney, Kruskal-Wallis, Wilcoxon Matched Pairs Test with significance level p < 0,05 were used. Six hundred dishes of culture medium have been used. There was growing in 94 (15,6%, being 82 (87,2% before and 12 (12,8% after cleaning and disinfection. Concerning the position on the bed, the samples obtained from mannitol salt agar medium showed significant retention on the lower position of bed. The results alert to flaws in the procedure for cleaning and disinfection from the mattresses

  12. Pressure RElieving Support SUrfaces: a Randomised Evaluation 2 (PRESSURE 2): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Brown, Sarah; Smith, Isabelle L; Brown, Julia M; Hulme, Claire; McGinnis, Elizabeth; Stubbs, Nikki; Nelson, E Andrea; Muir, Delia; Rutherford, Claudia; Walker, Kay; Henderson, Valerie; Wilson, Lyn; Gilberts, Rachael; Collier, Howard; Fernandez, Catherine; Hartley, Suzanne; Bhogal, Moninder; Coleman, Susanne; Nixon, Jane E

    2016-12-20

    Pressure ulcers represent a major burden to patients, carers and the healthcare system, affecting approximately 1 in 17 hospital and 1 in 20 community patients. They impact greatly on an individual's functional status and health-related quality of life. The mainstay of pressure ulcer prevention practice is the provision of pressure redistribution support surfaces and patient repositioning. The aim of the PRESSURE 2 study is to compare the two main mattress types utilised within the NHS: high-specification foam and alternating pressure mattresses, in the prevention of pressure ulcers. PRESSURE 2 is a multicentre, open-label, randomised, double triangular, group sequential, parallel group trial. A maximum of 2954 'high-risk' patients with evidence of acute illness will be randomised on a 1:1 basis to receive either a high-specification foam mattress or alternating-pressure mattress in conjunction with an electric profiling bed frame. The primary objective of the trial is to compare mattresses in terms of the time to developing a new Category 2 or above pressure ulcer by 30 days post end of treatment phase. Secondary endpoints include time to developing new Category 1 and 3 or above pressure ulcers, time to healing of pre-existing Category 2 pressure ulcers, health-related quality of life, cost-effectiveness, incidence of mattress change and safety. Validation objectives are to determine the responsiveness of the Pressure Ulcer Quality of Life-Prevention instrument and the feasibility of having a blinded endpoint assessment using photography. The trial will have a maximum of three planned analyses with unequally spaced reviews at event-driven coherent cut-points. The futility boundaries are constructed as non-binding to allow a decision for stopping early to be overruled by the Data Monitoring and Ethics Committee. The double triangular, group sequential design of the PRESSURE 2 trial will provide an efficient design through the possibility of early stopping for

  13. 16 CFR 1633.2 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... terms, for definitions of these items. (b) Foundation means a ticking covered structure used to support a mattress or sleep surface. The structure may include constructed frames, foam, box springs, or... taped border edge of a mattress or foundation that joins the top and/or bottom with the side panels. (h...

  14. Factors associated with allergen sensitizations in patients with asthma and/or rhinitis in China.

    Science.gov (United States)

    Li, Jing; Huang, Ying; Lin, Xiaoping; Zhao, Deyu; Tan, Guolin; Wu, Jinzhun; Zhao, Changqing; Zhao, Jing; Spangfort, Michael D; Lai, Xuxin; Zhong, Nanshan

    2012-01-01

    Allergen sensitization is influenced by genetic and environmental factors; however, the factors related to sensitizations in patients with rhinitis and asthma in China are largely unknown. This study investigated the factors associated with allergen sensitizations in patients with asthma and rhinitis in China. A cross-sectional survey was performed in 6304 patients with asthma and/or rhinitis from four regions of China. Patients completed a standardized questionnaire related to respiratory and allergic symptoms, family history of allergic diseases, smoking history, environmental exposure, and eating behaviors. They underwent skin-prick tests (SPTs) with 13 common aeroallergens. Blood samples were collected from 2268 of patients for specific IgE (sIgE) measurements against 16 common aeroallergens. Patients with both asthma and rhinitis had higher prevalence of SPT and sIgE positivity to most allergens than those with asthma or rhinitis alone (p history of allergic rhinitis, air-conditioner usage, sleeping on a mattress, and frequently eating meat were associated with increased risk of SPT and sIgE positivity. Using air-conditioner and sleeping on a mattress were further found to be associated with sIgE positivity to mites and molds. However, increased age and fish, fruit, and raw vegetable intake decreased the risk of SPT and sIgE positivity. Family history of allergic rhinitis, male gender, using an air conditioner, sleeping on a mattress, and frequent meat consumption are risk factors for allergen sensitizations, whereas increased age and frequent fish, fruit, and raw vegetable consumption may protect patients with asthma and/or rhinitis from developing sensitizations in China.

  15. Forced-Air Warming Provides Better Control of Body Temperature in Porcine Surgical Patients

    Directory of Open Access Journals (Sweden)

    Brian T. Dent

    2016-09-01

    Full Text Available Background: Maintaining normothermia during porcine surgery is critical in ensuring subject welfare and recovery, reducing the risk of immune system compromise and surgical-site infection that can result from hypothermia. In humans, various methods of patient heating have been demonstrated to be useful, but less evaluation has been performed in techniques to prevent hypothermia perioperatively in pigs. Methods: We compared body temperature regulation during surgery before and after modification of the ambient temperature of the operating laboratories. Three different methods of heating were then compared; a standard circulating water mattress, a resistive fabric blanket, and a forced hot air system. The primary measure was percentage of temperature readings outside a specification range of 36.7–40.0 °C. Results: Tighter control of the ambient temperature while using a circulating water mattress reduced the occurrence of out-of-specification body temperature readings from 20.8% to 5.0%, with most of these the result of hypothermia. Use of a resistive fabric blanket further reduced out-of-specification readings to 1.5%, with a slight increase in the occurrence of hyperthermia. Use of a forced air system reduced out-of-specification readings to less 0.1%. Conclusions: Maintenance of normothermia perioperatively in pig can be improved by tightly controlling ambient temperatures. Use of a resistive blanket or a forced air system can lead to better control than a circulating water mattress, with the forced air system providing a faster response to temperature variations and less chance of hyperthermia.

  16. 16 CFR 1633.6 - Quality assurance requirements.

    Science.gov (United States)

    2010-01-01

    ... that mattress sets manufactured for sale are the same as the qualified and/or confirmed prototype on... are the same as those used in the prototype on which they are based; (2) Designation of a production lot that is represented by the prototype; and (3) Inspection of mattress sets produced for sale...

  17. Ignition Delay of Combustible Materials in Normoxic Equivalent Environments

    Science.gov (United States)

    McAllister, Sara; Fernandez-Pello, Carlos; Ruff, Gary; Urban, David

    2009-01-01

    Material flammability is an important factor in determining the pressure and composition (fraction of oxygen and nitrogen) of the atmosphere in the habitable volume of exploration vehicles and habitats. The method chosen in this work to quantify the flammability of a material is by its ease of ignition. The ignition delay time was defined as the time it takes a combustible material to ignite after it has been exposed to an external heat flux. Previous work in the Forced Ignition and Spread Test (FIST) apparatus has shown that the ignition delay in the currently proposed space exploration atmosphere (approximately 58.6 kPa and32% oxygen concentration) is reduced by 27% compared to the standard atmosphere used in the Space Shuttle and Space Station. In order to determine whether there is a safer environment in terms of material flammability, a series of piloted ignition delay tests using polymethylmethacrylate (PMMA) was conducted in the FIST apparatus to extend the work over a range of possible exploration atmospheres. The exploration atmospheres considered were the normoxic equivalents, i.e. reduced pressure conditions with a constant partial pressure of oxygen. The ignition delay time was seen to decrease as the pressure was reduced along the normoxic curve. The minimum ignition delay observed in the normoxic equivalent environments was nearly 30% lower than in standard atmospheric conditions. The ignition delay in the proposed exploration atmosphere is only slightly larger than this minimum. Interms of material flammability, normoxic environments with a higher pressure relative to the proposed pressure would be desired.

  18. Environmental and mucosal microbiota and their role in childhood asthma.

    Science.gov (United States)

    Birzele, L T; Depner, M; Ege, M J; Engel, M; Kublik, S; Bernau, C; Loss, G J; Genuneit, J; Horak, E; Schloter, M; Braun-Fahrländer, C; Danielewicz, H; Heederik, D; von Mutius, E; Legatzki, A

    2017-01-01

    High microbial diversity in the environment has been associated with lower asthma risk, particularly in children exposed to farming. It remains unclear whether this effect operates through an altered microbiome of the mucosal surfaces of the airways. DNA from mattress dust and nasal samples of 86 school age children was analyzed by 454 pyrosequencing of the 16S rRNA gene fragments. Based on operational taxonomic units (OTUs), bacterial diversity and composition were related to farm exposure and asthma status. Farm exposure was positively associated with bacterial diversity in mattress dust samples as determined by richness (P = 8.1 × 10 -6 ) and Shannon index (P = 1.3 × 10 -5 ). Despite considerable agreement of richness between mattress and nasal samples, the association of richness with farming in nasal samples was restricted to a high gradient of farm exposure, that is, exposure to cows and straw vs no exposure at all. In mattress dust, the genera Clostridium, Facklamia, an unclassified genus within the family of Ruminococcaceae, and six OTUs were positively associated with farming. Asthma was inversely associated with richness [aOR = 0.48 (0.22-1.02)] and Shannon index [aOR = 0.41 (0.21-0.83)] in mattress dust and to a lower extent in nasal samples [richness aOR 0.63 = (0.38-1.06), Shannon index aOR = 0.66 (0.39-1.12)]. The stronger inverse association of asthma with bacterial diversity in mattress dust as compared to nasal samples suggests microbial involvement beyond mere colonization of the upper airways. Whether inhalation of metabolites of environmental bacteria contributes to this phenomenon should be the focus of future research. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. 76 FR 4735 - Standard on Fire Brigades; Extension of the Office of Management and Budget's (OMB) Approval of...

    Science.gov (United States)

    2011-01-26

    ... paperwork and respondent (i.e., employer) burden, conducts a preclearance consultation program to provide... requirements in accordance with the Paperwork Reduction Act of 1995 (44 U.S.C. 3506(c)(2)(A)). This program... use of flammable liquids and gases, toxic chemicals, radioactive sources, and water-reactive...

  20. YEAR-ROUND HOUSEDUST MITE LEVELS ON THE HIGHVELD

    African Journals Online (AJOL)

    electricity. Where possible dust was collected from the main bedroom, using the Rainbow Vacuum Cleaner. Bed linen was removed and the mattress was sampled. An area of 1 m' on the mattress was vacuumed for 2 minutes. The dust sampled was placed in a plastic bag, sealed and labelled. Thereafter the carpet next to.

  1. 16 CFR 1633.9 - Glossary of terms.

    Science.gov (United States)

    2010-01-01

    ... and stationary (see Figure 11). (m) Futon. A flexible mattress generally used on the floor that can be... riser. This is a frame of sofa seating height with two equal size mattresses without a backrest. The... or two single beds as in a high riser (see Figure 11). (dd) Tufted means buttoned or laced through...

  2. Monte-Carlo Simulation and Automated Test Bench for Developing a Multichannel NIR-Based Vital-Signs Monitor.

    Science.gov (United States)

    Bruser, Christoph; Strutz, Nils; Winter, Stefan; Leonhardt, Steffen; Walter, Marian

    2015-06-01

    Unobtrusive, long-term monitoring of cardiac (and respiratory) rhythms using only non-invasive vibration sensors mounted in beds promises to unlock new applications in home and low acuity monitoring. This paper presents a novel concept for such a system based on an array of near infrared (NIR) sensors placed underneath a regular bed mattress. We focus on modeling and analyzing the underlying technical measurement principle with the help of a 2D model of a polyurethane foam mattress and Monte-Carlo simulations of the opto-mechanical interaction responsible for signal genesis. Furthermore, a test rig to automatically and repeatably impress mechanical vibrations onto a mattress is introduced and used to identify the properties of a prototype implementation of the proposed measurement principle. Results show that NIR-based sensing is capable of registering miniscule deformations of the mattress with a high spatial specificity. As a final outlook, proof-of-concept measurements with the sensor array are presented which demonstrate that cardiorespiratory movements of the body can be detected and that automatic heart rate estimation at competitive error levels is feasible with the proposed approach.

  3. Flooring for Schools: Unsightly Walkways

    Science.gov (United States)

    Baxter, Mark

    2011-01-01

    Many mattress manufacturers recommend that consumers rotate their mattresses at least twice a year to help prevent soft spots from developing and increase the product's life span. It's unfortunate that the same kind of treatment can't be applied to flooring for schools, such as carpeting, especially in hallways. Being able to flip or turn a carpet…

  4. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    OpenAIRE

    Otto Dvořák

    2016-01-01

    This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  5. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    Directory of Open Access Journals (Sweden)

    Otto Dvořák

    2016-07-01

    Full Text Available This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  6. The family of standard hydrogen monitoring system computer software design description: Revision 2

    International Nuclear Information System (INIS)

    Bender, R.M.

    1994-01-01

    In March 1990, 23 waste tanks at the Hanford Nuclear Reservation were identified as having the potential for the buildup of gas to a flammable or explosive level. As a result of the potential for hydrogen gas buildup, a project was initiated to design a standard hydrogen monitoring system (SHMS) for use at any waste tank to analyze gas samples for hydrogen content. Since it was originally deployed three years ago, two variations of the original system have been developed: the SHMS-B and SHMS-C. All three are currently in operation at the tank farms and will be discussed in this document. To avoid confusion in this document, when a feature is common to all three of the SHMS variants, it will be referred to as ''The family of SHMS.'' When it is specific to only one or two, they will be identified. The purpose of this computer software design document is to provide the following: the computer software requirements specification that documents the essential requirements of the computer software and its external interfaces; the computer software design description; the computer software user documentation for using and maintaining the computer software and any dedicated hardware; and the requirements for computer software design verification and validation

  7. Could martial arts fall training be safe for persons with osteoporosis?: a feasibility study

    Science.gov (United States)

    2010-01-01

    Background Osteoporosis is a well-established risk factor for fall-related hip fractures. Training fall arrest strategies, such as martial arts (MA) fall techniques, might be useful to prevent hip fractures in persons with osteoporosis, provided that the training itself is safe. This study was conducted to determine whether MA fall training would be safe for persons with osteoporosis extrapolated from the data of young adults and using stringent safety criteria. Methods Young adults performed sideways and forward MA falls from a kneeling position on both a judo mat and a mattress as well as from a standing position on a mattress. Hip impact forces and kinematic data were collected. For each condition, the highest hip impact force was compared with two safety criteria based on the femoral fracture load and the use of a hip protector. Results The highest hip impact force during the various fall conditions ranged between 1426 N and 3132 N. Sideways falls from a kneeling and standing position met the safety criteria if performed on the mattress (max 1426 N and 2012 N, respectively) but not if the falls from a kneeling position were performed on the judo mat (max 2219 N). Forward falls only met the safety criteria if performed from a kneeling position on the mattress (max 2006 N). Hence, forward falls from kneeling position on a judo mat (max 2474 N) and forward falls from standing position on the mattress (max 3132 N) did not meet both safety criteria. Conclusions Based on the data of young adults and safety criteria, the MA fall training was expected to be safe for persons with osteoporosis if appropriate safety measures are taken: during the training persons with osteoporosis should wear hip protectors that could attenuate the maximum hip impact force by at least 65%, perform the fall exercises on a thick mattress, and avoid forward fall exercises from a standing position. Hence, a modified MA fall training might be useful to reduce hip fracture risk in persons with

  8. Could martial arts fall training be safe for persons with osteoporosis?: a feasibility study

    Directory of Open Access Journals (Sweden)

    Smulders Ellen

    2010-04-01

    Full Text Available Abstract Background Osteoporosis is a well-established risk factor for fall-related hip fractures. Training fall arrest strategies, such as martial arts (MA fall techniques, might be useful to prevent hip fractures in persons with osteoporosis, provided that the training itself is safe. This study was conducted to determine whether MA fall training would be safe for persons with osteoporosis extrapolated from the data of young adults and using stringent safety criteria. Methods Young adults performed sideways and forward MA falls from a kneeling position on both a judo mat and a mattress as well as from a standing position on a mattress. Hip impact forces and kinematic data were collected. For each condition, the highest hip impact force was compared with two safety criteria based on the femoral fracture load and the use of a hip protector. Results The highest hip impact force during the various fall conditions ranged between 1426 N and 3132 N. Sideways falls from a kneeling and standing position met the safety criteria if performed on the mattress (max 1426 N and 2012 N, respectively but not if the falls from a kneeling position were performed on the judo mat (max 2219 N. Forward falls only met the safety criteria if performed from a kneeling position on the mattress (max 2006 N. Hence, forward falls from kneeling position on a judo mat (max 2474 N and forward falls from standing position on the mattress (max 3132 N did not meet both safety criteria. Conclusions Based on the data of young adults and safety criteria, the MA fall training was expected to be safe for persons with osteoporosis if appropriate safety measures are taken: during the training persons with osteoporosis should wear hip protectors that could attenuate the maximum hip impact force by at least 65%, perform the fall exercises on a thick mattress, and avoid forward fall exercises from a standing position. Hence, a modified MA fall training might be useful to reduce hip

  9. Association between stall surface and some animal welfare measurements in freestall dairy herds using recycled manure solids for bedding.

    Science.gov (United States)

    Husfeldt, A W; Endres, M I

    2012-10-01

    The objective of this cross-sectional study was to investigate the association between stall surface and some animal welfare measurements in upper Midwest US dairy operations using recycled manure solids as bedding material. The study included 34 dairy operations with herd sizes ranging from 130 to 3,700 lactating cows. Forty-five percent of the herds had mattresses and 55% had deep-bedded stalls. Farms were visited once between July and October 2009. At the time of visit, at least 50% of the cows in each lactating pen were scored for locomotion, hygiene, and hock lesions. On-farm herd records were collected for the entire year and used to investigate mortality, culling, milk production, and mastitis incidence. Stall surface was associated with lameness and hock lesion prevalence. Lameness prevalence (locomotion score ≥ 3 on a 1 to 5 scale) was lower in deep-bedded freestalls (14.4%) than freestalls with mattresses (19.8%). Severe lameness prevalence (locomotion score ≥ 4) was also lower for cows housed in deep-bedded freestalls (3.6%) than for cows housed in freestalls with mattresses (5.9%). In addition, the prevalence of hock lesions (hock lesion scores ≥ 2 on a 1 to 3 scale, with 1=no lesion, 2=hair loss or mild lesion, and 3=swelling or severe lesion) and severe hock lesions (hock lesion score=3) was lower in herds with deep-bedded freestalls (49.4%; 6.4%) than in herds with mattresses (67.3%; 13.2%). Herd turnover rates were not associated with stall surface; however, the percentage of removals due to voluntary (low milk production, disposition, and dairy) and involuntary (death, illness, injury, and reproductive) reasons was different between deep-bedded and mattress-based freestalls. Voluntary removals averaged 16% of all herd removals in deep-bedded herds, whereas in mattress herds, these removals were 8%. Other welfare measurements such as cow hygiene, mortality rate, mastitis incidence, and milk production were not associated with stall surface

  10. 49 CFR 193.2187 - Nonmetallic membrane liner.

    Science.gov (United States)

    2010-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS Design Lng Storage Tanks § 193.2187 Nonmetallic membrane liner. A flammable nonmetallic membrane liner may not be used as an inner container in a storage tank...

  11. Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears.

    Science.gov (United States)

    Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng

    2010-11-01

    For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

  12. 46 CFR 154.1000 - Applicability.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Applicability. 154.1000 Section 154.1000 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR... § 154.1000 Applicability. Sections 154.1005 through 154.1020 apply to flammable cargo and ammonia...

  13. 16 CFR 1611.38 - Maintenance of records by those furnishing guaranties.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Maintenance of records by those furnishing... ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.38 Maintenance of records by those furnishing guaranties. (a) In order to properly administer and enforce section...

  14. 29 CFR 1915.54 - Welding, cutting and heating of hollow metal containers and structures not covered by § 1915.12.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Welding, cutting and heating of hollow metal containers and... STANDARDS FOR SHIPYARD EMPLOYMENT Welding, Cutting and Heating § 1915.54 Welding, cutting and heating of... which have contained flammable substances shall, before welding, cutting, or heating is undertaken on...

  15. 30 CFR 56.4100 - Smoking and use of open flames.

    Science.gov (United States)

    2010-07-01

    ... 56.4100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire... flammable gases are— (a) Used or transported in a manner that could create a fire hazard; or (b) Stored or...

  16. Preparation and flammability of high density polyethylene/paraffin/organophilic montmorillonite hybrids as a form stable phase change material

    International Nuclear Information System (INIS)

    Cai, Yibing; Hu, Yuan; Song, Lei; Kong, Qinghong; Yang, Rui; Zhang, Yinping; Chen, Zuyao; Fan, Weicheng

    2007-01-01

    A kind of form stable phase change material (PCM) based on high density polyethylene (HDPE), paraffin, organophilic montmorillonite (OMT) and intumescent flame retardant (IFR) hybrids is prepared by using a twin screw extruder technique. This kind of form stable PCM is made of paraffin as a dispersed phase change material and HDPE as a supporting material. The structure of the montmorillonite (MMT) and OMT is characterized by X-ray diffraction (XRD) and high resolution electron microscopy (HREM). The analysis indicates that the MMT is a kind of lamellar structure, and the structure does not change after organic modification. However, the structure of the hybrid is evidenced by the XRD and scanning electronic microscope (SEM). Its thermal stability, latent heat and flame retardant properties are given by the Thermogravimetry analysis (TGA), differential scanning calorimeter (DSC) method and cone calorimeter, respectively. Synergy is observed between the OMT and IFR. The XRD result indicates that the paraffin intercalates into the silicate layers of the OMT, thus forming a typically intercalated hybrid. The SEM investigation and DSC result show that the additives of OMT and IFR have hardly any effect on the HDPE/paraffin three dimensional netted structure and the latent heat. In TGA curves, although the onset of weight loss of flame-retardant form stable PCMs occur at a lower temperature than that of form stable PCM, flame-retardant form stable PCMs produce a large amount of char residue at 700 o C. The synergy between OMT and IFR leads to the decrease of the heat release rate (HRR), contributing to improvement of the flammability performance

  17. Comfort zone-design free stalls: do they influence the stall use behavior of lame cows?

    Science.gov (United States)

    Cook, N B; Marin, M J; Mentink, R L; Bennett, T B; Schaefer, M J

    2008-12-01

    The behavior of 59 cows in 4 herds, each with Comfort Zone-design free stalls with dimensions suitable for 700-kg, mature Holstein dairy cows, was filmed for a 48-h period. Comparison was made between nonlame, slightly lame, and moderately lame cows on either rubber-crumb-filled mattress stall surfaces bedded with a small amount of sawdust (2 herds) or a Pack Mat design, which consisted of a rubber-crumb-filled mattress pad installed 5 cm below a raised rear curb, bedded with 5 to 8 cm of sand bedding (2 herds). All other stall design components were similar. Despite adequate resting space and freedom to perform normal rising and lying movements, lame cows on mattresses stood in the stall for >2 h longer than nonlame cows. Although a significant increase in stall standing behavior was observed in lame cows on Pack Mat stalls, the mean (95% confidence interval) standing time in the stall was only 0.7 (0 to 3.0) h/d for nonlame cows and 1.6 (0 to 4.2) h/d for moderately lame cows, which was less than the 2.1 (0 to 4.4), 4.3 (1.6 to 6.9), and 4.9 (2.5 to 7.3) h/d spent standing in the stall for nonlame, slightly lame, and moderately lame cows on mattresses, respectively. This observation supports the hypothesis that it is the nature of the stall surface that dictates changes in stall standing behavior observed in lame cows, rather than other components of stall design. The finding that only 5 to 8 cm of sand over a mattress pad provides most of the benefits of deep sand-bedded stalls, along with other advantages related to stall maintenance and manure handling, gives farmers another useful housing alternative with which to improve cow comfort and well-being.

  18. 16 CFR 1611.39 - Shipments under section 11(c) of the act.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.39 Shipments... commerce for such purpose maintains records which establish (1) that the textile fabric or article of... been completed, as well as records to show the disposition of such textile fabric or article of wearing...

  19. 29 CFR 1910.253 - Oxygen-fuel gas welding and cutting.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Oxygen-fuel gas welding and cutting. 1910.253 Section 1910..., DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Welding, Cutting and Brazing § 1910.253 Oxygen-fuel gas welding and cutting. (a) General requirements—(1) Flammable mixture. Mixtures of fuel gases...

  20. 16 CFR 1611.35 - Testing certain classes of fabric and film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Testing certain classes of fabric and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1) Except as...

  1. 16 CFR 1611.33 - Test procedures for textile fabrics and film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test procedures for textile fabrics and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.33 Test procedures for textile fabrics and film. (a)(1) All textile fabrics (except those with a nitro-cellulose...

  2. 78 FR 35875 - Proposed Extension of Approval of Information Collection; Comment Request: Clothing Textiles...

    Science.gov (United States)

    2013-06-14

    ... Information Collection; Comment Request: Clothing Textiles, Vinyl Plastic Film AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: As required by the Paperwork Reduction Act of 1995 (44 U.S.C. chapter 35... Clothing Textiles (16 CFR part 1610) and the Standard for the Flammability of Vinyl Plastic Film (16 CFR...

  3. The temporal outcomes of open versus arthroscopic knotted and knotless rotator cuff repair over 5 years

    Science.gov (United States)

    Lucena, Thomas R; Lam, Patrick H; Millar, Neal L

    2015-01-01

    Background The present study aimed to determine how repair technique influenced structural and clinical outcomes at 5 years post-surgery. Methods Three cohorts of patients had repair of a symptomatic rotator cuff tear using (i) an open double-row mattress repair technique (n = 25); (ii) arthroscopic single-row simple suture knotted technique (n = 25); or (iii) arthroscopic single-row inverted mattress knotless technique (n = 36) by one surgeon. Standardized patient- and examiner-determined outcomes were obtained pre-operatively and postoperatively with a validated protocol, ultrasound were also performed at the same time. Results Retear occurred more often after open repair (48%) at 5 years than after arthroscopic knotted (33%) and arthroscopic knotless (26%) repair. Retear was associated with increasing age, pre-operative tear size and weaker pre-operative and 5 years postoperative cuff strength. Between 2 years and 5 years, the open repair group experienced an increase in the frequency of pain during activity, as well as in the difficulty experienced and the severity of pain during overhead activities (p repair group. Conclusions At 5-year follow-up, arthroscopic rotator cuff repair techniques resulted in fewer retears and better outcomes compared to an open double-row technique. PMID:27582985

  4. Irradiated ignition over solid materials in reduce pressure environment: Fire safety issue in man-made enclosure system

    Science.gov (United States)

    Nakamura, N.; Aoki, A.

    Effects of ambient pressure and oxygen yield on irradiated ignition characteristics over solid combustibles have been studied experimentally Aim of the present study is to elucidate the flammability and chance of fire in depressurized enclosure system and give ideas for the fire safety and fire fighting strategies in such environment Thin cellulosic paper is considered as the solid combustible since cellulose is one of major organic compounds and flammables in the nature Applied atmosphere consists of inert gas either CO2 or N2 and oxygen and various mixture ratios are of concerned Total ambient pressure level is varied from 0 1MPa standard atmospheric pressure to 0 02MPa Ignition is initiated by external thermal flux exposed into the solid surface as a model of unexpected thermal input to initiate the localized fire Thermal degradation of the solid induces combustible gaseous products e g CO H2 or other low class of HCs and the gas mixes with ambient oxygen to form the combustible mixture over the solid Heat transfer from the hot irradiated surface into the mixture accelerates the local exothermic reaction in the gas phase and finally thermal runaway ignition is achieved Ignition event is recorded by high-speed digital video camera to analyze the ignition characteristics Flammable map in partial pressure of oxygen Pox and total ambient pressure Pt plane is made to reveal the fire hazard in depressurized environment Results show that wider flammable range is obtained depending on the imposed ambient

  5. Novel bed integrated ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    This study presents a novel method for advanced ventilation of hospital wards leading to improved air quality at reduced ventilation rate. The idea is to evacuate the bio-effluents generated from patients’ body by local exhaustion before being spread in the room. This concept was realized by using...... a mattress having a suction opening from which bio-effluents generated from human body are exhausted. Experiments were conducted in a full-scale two-bed hospital room mock-up, 4.7 x 5.3 x 2.6 m3 (W x L x H). Only one of the patients’ beds was equipped with the ventilated mattress. The room was air...... conditioned via mixing total volume ventilation system supplying air through a ceiling mounted diffuser. All experiments were performed at room air temperature of 23ºC. A thermal manikin was used to simulate a polluting patient on the bed equipped with the ventilated mattress. Two heated dummies were used...

  6. Estimation of lower flammability limits of C-H compounds in air at atmospheric pressure, evaluation of temperature dependence and diluent effect.

    Science.gov (United States)

    Mendiburu, Andrés Z; de Carvalho, João A; Coronado, Christian R

    2015-03-21

    Estimation of the lower flammability limits of C-H compounds at 25 °C and 1 atm; at moderate temperatures and in presence of diluent was the objective of this study. A set of 120 C-H compounds was divided into a correlation set and a prediction set of 60 compounds each. The absolute average relative error for the total set was 7.89%; for the correlation set, it was 6.09%; and for the prediction set it was 9.68%. However, it was shown that by considering different sources of experimental data the values were reduced to 6.5% for the prediction set and to 6.29% for the total set. The method showed consistency with Le Chatelier's law for binary mixtures of C-H compounds. When tested for a temperature range from 5 °C to 100 °C, the absolute average relative errors were 2.41% for methane; 4.78% for propane; 0.29% for iso-butane and 3.86% for propylene. When nitrogen was added, the absolute average relative errors were 2.48% for methane; 5.13% for propane; 0.11% for iso-butane and 0.15% for propylene. When carbon dioxide was added, the absolute relative errors were 1.80% for methane; 5.38% for propane; 0.86% for iso-butane and 1.06% for propylene. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. 30 CFR 75.321 - Air quality.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away flammable...

  8. 16 CFR 1610.33 - Test procedures for textile fabrics and film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test procedures for textile fabrics and film... for textile fabrics and film. (a)(1) All textile fabrics (except those with a nitro-cellulose fiber... under the procedures outlined in part 1611, Standard for the Flammability of Vinyl Plastic Film, and if...

  9. 14 CFR 33.17 - Fire protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection. 33.17 Section 33.17... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.17 Fire protection. (a) The design and... protection unless damage by fire will not cause leakage or spillage of a hazardous quantity of flammable...

  10. Associations of soft flooring materials in free stalls with milk yield, clinical mastitis, teat lesions, and removal of dairy cows.

    Science.gov (United States)

    Ruud, L E; Bøe, K E; Osterås, O

    2010-04-01

    The objective was to test if there was an association between free-stall base softness and milk yield, incidence of clinical mastitis (CM), teat lesions, and removal of cows. In a questionnaire sent to 1,923 dairy farms presumed to be using free-stall housing, farmers were asked for information regarding housing and stall base; for example, the year of installation and the product name or brand of their mats or mattresses. This information was merged with data for milk yield, CM, teat lesions, and removal of cows extracted from the Norwegian Dairy Herd Recording System for the years after installation of mats or mattresses. After exclusion of invalid contributions, the data set consisted of 29,326 lactations for milk yield distributed over 363 free-stalled herds in Norway. The farms were stratified into 5 categories according to the softness of the stall surface measured as millimeter impact of a sphere with a diameter of 120 mm at 2-kN load: 1=concrete, softness of 0mm; 2=rubber, softness of 1 to 8mm; 3=soft mats, softness of 9 to 16 mm; 4=multilayer mats, softness of 17 to 24 mm; and 5=mattresses, softness over 24 mm. Lactation curves were estimated as modified Wood's lactation curves using test-day data and mixed models with repeated measurements, adjusting for days in milk, parity, and softness of free-stall flooring. Herds on concrete free-stall bases yielded 6,727+/-146 kg of milk from 5 to 305 days in milk. In comparison, herds showed a decrease of 0.3% on rubber, an increase of 2.4% on soft mats, an increase of 4.5% on multilayer mats, and an increase of 3.9% on mattresses. Compared with concrete, the hazard ratio (HR) of CM was less on rubber, multilayer mats, and mattresses [HR=0.89 (0.79-0.99), 0.85 (0.73-0.996), and 0.80 (0.73-0.88), respectively]. Compared with concrete, the HR of teat lesions was less on rubber, soft mats, multilayer mats, and mattresses [HR=0.41 (0.26-0.65), 0.33 (0.24-0.44), 0.12 (0.04-0.38), and 0.47 (0.33-0.67), respectively]. The

  11. TWRS hydrogen mitigation portable standard hydrogen monitoring system platform design and fabrication engineering task plan

    International Nuclear Information System (INIS)

    Philipp, B.L.

    1997-01-01

    The primary function of portable gas monitoring is to quickly determine tank vapor space gas composition and gas release rate, and to detect gas release events. Characterization of the gas composition is needed for safety analysis. The lower flammability limit, as well as the peak burn temperature and pressure, are dependent upon the gas composition. If there is little or no knowledge about the gas composition, safety analysis utilize compositions that yield the worst case in a deflagration or detonation. This conservative approach to unknowns necessitates a significant increase in administrative and engineering costs. Knowledge of the true composition could lead to reductions in the assumptions and therefore contribute to a reduction in controls and work restrictions. Also, knowledge of the actual composition will be required information for the analysis that is needed to remove tanks from the Watch List. Similarly, the rate of generation and release of gases is required information for performing safety analysis, developing controls, designing equipment, and closing safety issues. To determine release rate, both the gas concentrations and the dome space ventilation rates (exhauster flow rate or passive dome/atmosphere exchange rate) are needed. Therefore, to quickly verify waste tank categorization or to provide additional characterization for tanks with installed gas monitoring, a temporary, portable standard hydrogen monitoring system is needed that can be used to measure gas compositions at both high and low sensitivities

  12. A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis

    Directory of Open Access Journals (Sweden)

    Sofía Ruiz de Gauna

    2016-01-01

    Full Text Available Background. Cardiopulmonary resuscitation (CPR feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin’s back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%. Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p<0.001. Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p<0.001. Median error in rate was 0.9 cpm (1.0%, with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces.

  13. NREL/NASA Internal Short-Circuit Instigator in Lithium Ion Cells

    Energy Technology Data Exchange (ETDEWEB)

    Keyser, Matthew; Long, Dirk; Pesaran, Ahmad; Darcy, Eric; Shoesmith, Mark; McCarthy, Ben

    2015-10-11

    Lithium-ion cells provide the highest specific energy (>280 Wh/kg) and energy density (>600 Wh/L) rechargeable battery building block to date with the longest life. Electrode/electrolyte thermal instability and flammability of the electrolyte of Li-ion cells make them prone to catastrophic thermal runaway under some rare internal short circuit conditions. Despite extensive QC/QA, standardized industry safety testing, and over 18 years of manufacturing experience, major recalls have taken place and incidents still occur. Many safety incidents that take place in the field originate due to an internal short that was not detectable or predictable at the point of manufacture. The Internal Short-Circuit Instigator can be used to study types of separators, non-flammable electrolytes, electrolyte additives, fusible tabs, propagation studies, and gas generation within a cell.

  14. Cat, dog and house dust mite allergen levels on children's soft toys.

    Science.gov (United States)

    Wu, Francis Fu-Sheng; Wu, Mei-Wen; Ting, Ming-Hui; Crane, Julian; Siebers, Rob

    2014-02-01

    Children's soft toys are known to harbour house dust mite (HDM) allergens, but little is known whether they harbour cat or dog allergens. The objective of the study was to measure cat (Fel d 1), dog (Can f 1) and HDM allergens on children's soft toys. Dust was collected from 40 children's soft toys and their mattresses. Data were collected on pet ownership. Dust samples were analysed for Fel d 1, Can f 1, Der p 1 and Der f 1 by enzyme-linked immunosorbent assay (ELISA) and results are expressed as median levels with inter-quartile ranges. Thirty-five (87.5%) soft toys had detectable Fel d 1 levels (median: 0.73 µg/g; inter-quartile range: 0.26-2.56 µg/g) while 34 (85%) had detectable Can f 1 levels (1.20 µg/g; 0.53-2.68). Correspondingly, 32 (80%) mattresses had detectable Fel d 1 levels (0.18 µg/g, 0.07-1.01) while 34 (85%) had detectable Can f 1 levels (0.50 µg/g; 0.33-1.06). All mattresses and soft toys had detectable HDM allergen (Der p 1 + Der f 1) levels with soft toys containing about three times higher levels than mattresses. In homes with cats (n = 10) Fel d 1 levels were higher on soft toys than homes without cats (2.49 versus 0.48 µg/g; p = 0.0009). In homes with dogs (n = 25) Can f 1 levels were generally higher on soft toys (1.38 versus 0.63 µg/g; p = 0.10). This study has shown that soft toys can harbour cat and dog allergen as well as HDM allergens, some with very high levels. Cat and dog ownership resulted in higher Fel d 1 and Can f 1 levels on soft toys and mattresses. The levels of Fel d 1, Can f 1 and HDM allergens on soft toys could be of importance to sensitized asthmatic children.

  15. 49 CFR 173.2 - Hazardous materials classes and index to hazard class definitions.

    Science.gov (United States)

    2010-10-01

    ....50 1 1.6 Extremely insensitive detonating substances 173.50 2 2.1 Flammable gas 173.115 2 2.2 Non-flammable compressed gas 173.115 2 2.3 Poisonous gas 173.115 3 Flammable and combustible liquid 173.120 4 4.1 Flammable solid 173.124 4 4.2 Spontaneously combustible material 173.124 4 4.3 Dangerous when wet...

  16. 49 CFR 172.400 - General labeling requirements.

    Science.gov (United States)

    2010-10-01

    ... 172.411 1.6 EXPLOSIVES 1.6 172.411 2.1 FLAMMABLE GAS 172.417 2.2 NONFLAMMABLE GAS 172.415 2.3 POISON GAS 172.416 3 (flammable liquid) Combustible liquid FLAMMABLE LIQUID (none) 172.419 4.1 FLAMMABLE... B) POISON 172.430 6.2 INFECTIOUS SUBSTANCE 1 172.432 7 (see § 172.403) RADIOACTIVE WHITE-I 172.436 7...

  17. Comparative study of three methods of esophageal anastomosis in dogs

    Directory of Open Access Journals (Sweden)

    Z. T. Abd Al-Maseeh

    2009-01-01

    Full Text Available This study was performed to compare three methods of esophageal anastomosis. Twenty four healthy adult dogs were used in this study. The animals were divided into three groups; each one consisted of 8 animals. In group 1; two layers were used to perform the esophageal anastomosis. The first layer represented simple interrupted suture to close the mucosa with knot inside the lumen, and the second layer represented horizontal mattress interrupted suture to close the other layers of esophagus. While in group 2; one layer of cross interrupted mattress suture was used to close all layers of esophageal wall, and in group 3; one layer of Schmieden's suture was used to close all layers of esophageal wall. The results of clinical, radiological and histopathological studies after 15 and 30 days of surgical operation revealed that most of the animals showed different degrees of difficulty concerning the moderate dysphagia and regurgitation. The radiological study showed significant difference of stenosis. The best results were recorded in the second group where the mean degree of stenosis was 7.69%, however the mean degree of stenosis was 42.80% in the first group, while the mean degree of stenosis in the third groups was 37.81%, through 30 days. The histopathological study of group 2 showed rapid healing of the site of anastomosis, lack of granulation tissue and consequently the less degree of stricture and other complications as compared with groups 1 and 3. The Schmieden's suture was characterized by its standard short time as compared with group 1 and 2, although accompanied by some complications. In conclusion this study revealed that the cross mattress suture used in the second group characterized by faster healing and minimal amount of fibrous tissue formation manifested by decrease in moderate degree of stenosis as compared with the two other suture patterns used in the first and third groups.

  18. Effects of bedding systems selected by manual muscle testing on sleep and sleep-related respiratory disturbances.

    Science.gov (United States)

    Tsai, Ling-Ling; Liu, Hau-Min

    2008-03-01

    In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.

  19. Chemical process safety management within the Department of Energy

    International Nuclear Information System (INIS)

    Piatt, J.A.

    1995-07-01

    Although the Department of Energy (DOE) is not well known for its chemical processing activities, the DOE does have a variety of chemical processes covered under OSHA's Rule for Process Safety Management of Highly Hazardous Chemicals (the PSM Standard). DOE, like industry, is obligated to comply with the PSM Standard. The shift in the mission of DOE away from defense programs toward environmental restoration and waste management has affected these newly forming process safety management programs within DOE. This paper describes the progress made in implementing effective process safety management programs required by the PSM Standard and discusses some of the trends that have supported efforts to reduce chemical process risks within the DOE. In June of 1994, a survey of chemicals exceeding OSHA PSM or EPA Risk Management Program threshold quantities (TQs) at DOE sites found that there were 22 processes that utilized toxic or reactive chemicals over TQs; there were 13 processes involving flammable gases and liquids over TQs; and explosives manufacturing occurred at 4 sites. Examination of the survey results showed that 12 of the 22 processes involving toxic chemicals involved the use of chlorine for water treatment systems. The processes involving flammable gases and liquids were located at the Strategic Petroleum Reserve and Naval petroleum Reserve sites

  20. 16 CFR 1610.34 - Only uncovered or exposed parts of wearing apparel to be tested.

    Science.gov (United States)

    2010-01-01

    ... 1611. (c) Plastic film or plastic-coated fabric used, or intended for use as the outer layer of... procedures set forth in § 1610.6. (b) If the outer layer of plastic film or plastic-coated fabric of a...—Standard for the Flammability of Vinyl Plastic Film. If the outer layer adheres to all or a portion of one...

  1. 29 CFR 1926.352 - Fire prevention.

    Science.gov (United States)

    2010-07-01

    ... structures which have contained toxic or flammable substances shall, before welding, cutting, or heating is..., cutting, or heating shall be done where the application of flammable paints, or the presence of other flammable compounds, or heavy dust concentrations creates a hazard. (d) Suitable fire extinguishing...

  2. 29 CFR 1915.12 - Precautions and the order of testing before entering confined and enclosed spaces and other...

    Science.gov (United States)

    2010-07-01

    ...): Additional provisions for work in spaces containing a flammable substance which also has a permissible... contain or have contained combustible or flammable liquids or gases; (iii) Spaces and adjacent spaces that...) Flammable atmospheres. (1) The employer shall ensure that spaces and adjacent spaces that contain or have...

  3. 49 CFR 173.8 - Exceptions for non-specification packagings used in intrastate transportation.

    Science.gov (United States)

    2010-10-01

    ... used to transport a flammable cryogenic liquid, hazardous substance, hazardous waste, or a marine... be used by an intrastate motor carrier for transportation of a flammable liquid petroleum product in... flammable liquid petroleum product in accordance with the provisions of paragraph (d) of this section. (d...

  4. An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.

    Science.gov (United States)

    Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P

    2017-11-01

    Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior

  5. Ignitability and explosibility of gases and vapors

    CERN Document Server

    Ma, Tingguang

    2015-01-01

    The book provides a systematic view on flammability and a collection of solved engineering problems in the fields of dilution and purge, mine gas safety, clean burning safety and gas suppression modeling. For the first time, fundamental principles of energy conservation are used to develop theoretical flammability diagrams and are then explored to understand various safety-related mixing problems. This provides the basis for a fully-analytical solution to any flammability problem. Instead of the traditional view that flammability is a fundamental material property, here flammability is discovered to be a result of the explosibility of air and the ignitability of fuel, or a process property. By exploring the more fundamental concepts of explosibility and ignitability, the safety targets of dilution and purge can be better defined and utilized for guiding safe operations in process safety. This book provides various engineering approaches to mixture flammability, benefiting not only the safety students, but al...

  6. Nanocompósitos de polietileno/argila bentonita nacional: influência da argila e do agente compatibilizante PE-g-MA nas propriedades mecânicas e de inflamabilidade Polyethylene/national bentonite clay nanocomposites: influence of clay and PE-g-MA coupling agent on the mechanical properties and flammability

    Directory of Open Access Journals (Sweden)

    Gustavo F. Brito

    2008-06-01

    Full Text Available Nanocompósitos de polietileno de alta densidade/argila bentonita nacional foram preparados por intercalação por fusão. A influência da adição da argila sem tratamento e da argila tratada com o sal quaternário de amônio Cetremide e do polietileno graftizado com anidrido maléico (PE-g-MA como agente compatibilizante foi avaliada. Os sistemas obtidos foram caracterizados por inflamabilidade, propriedades mecânicas e reológicas, difração de raios X e microscopia eletrônica de transmissão. Os resultados de difração de raios X e microscopia eletrônica de transmissão indicaram a obtenção de nanocompósitos com estruturas parcialmente esfoliadas e/ou intercaladas que conduziram ao aumento do módulo de elasticidade e do valor do torque. O teste de inflamabilidade mostrou que a adição da argila na matriz polimérica e a presença do PE-g-MA retardaram a velocidade de queima do sistema, ou seja, diminuíram a inflamabilidade do PE puro. Em geral, o sistema contendo o agente compatibilizante (PE-g-MA exibiu melhorias na estabilidade térmica e nanocompósitos parcialmente esfoliados foram formados, quando comparados à matriz de polietileno de alta densidade. O polietileno graftizado com anidrido maléico não apenas promoveu a esfoliação da argila, mas também facilitou a adesão carga-matriz, obtendo-se com isso melhorias nos resultados mecânicos do sistema.High density polyethylene/national bentonite clay nanocomposites were prepared with the melt intercalation technique. The effect of the clay without treatment and clay treated with quaternary ammonium salt Cetremide with polyethylene-graft-maleic anhydride as coupling agent was evaluated. The systems were characterized by flammability, mechanical and rheological properties, X ray diffraction and transmission electron microscopy. In general, the results of X ray diffraction and transmission electron microscopy showed partially exfoliated and/or intercalated structures with

  7. A remote monitor of bed patient cardiac vibration, respiration and movement.

    Science.gov (United States)

    Mukai, Koji; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Maki, Hiromichi; Caldwell, W Morton

    2009-01-01

    We have developed a remote system for monitoring heart rate, respiration rate and movement behavior of at-home elderly people who are living alone. The system consists of a 40 kHz ultrasonic transmitter and receiver, linear integrated circuits, a low-power 8-bit single chip microcomputer and an Internet server computer. The 40 kHz ultrasonic transmitter and receiver are installed into a bed mattress. The transmitted signal diffuses into the bed mattress, and the amplitude of the received ultrasonic wave is modulated by the shape of the mattress and parameters such as respiration, cardiac vibration and movement. The modulated ultrasonic signal is received and demodulated by an envelope detection circuit. Low, high and band pass filters separate the respiration, cardiac vibration and movement signals, which are fed into the microcontroller and digitized at a sampling rate of 50 Hz by 8-bit A/D converters. The digitized data are sent to the server computer as a serial signal. This computer stores the data and also creates a graphic chart of the latest hour. The person's family or caregiver can download this chart via the Internet at any time.

  8. 29 CFR 1915.11 - Scope, application and definitions applicable to this subpart.

    Science.gov (United States)

    2010-07-01

    ... limit of a flammable or combustible substance. Immediately dangerous to life or health (IDLH) means an...; or (2) The space is flooded with water and the vapor concentration of flammable or combustible... limit for the flammable or combustible material. Labeled means identified with a sign, placard, or other...

  9. 29 CFR Appendix A to Subpart B of... - Compliance Assistance Guidelines for Confined and Enclosed Spaces and Other Dangerous Atmospheres

    Science.gov (United States)

    2010-07-01

    ... flammable substance below 10 percent of the LEL may be above the OSHA permissible exposure limit for that... explosive limit.” The terms lower flammable limit (LFL) and lower explosive limit (LEL) are used... upper flammable limit (UFL) and upper explosive limit (UEL) are used interchangeably in fire science...

  10. Environmental Assessment, Project MOUNTAINVIEW Facility, Buckley Air Force Base, Colorado

    Science.gov (United States)

    2011-10-01

    noise exposures are considered harmless . The standard defines a “hazardous noise environment” where continuous exposures are at or above 85 dBA. The...regulated waste at Buckley AFB (BAFB 2010c). Hazardous wastes generated at Buckley AFB include pesticides, herbicides , deicing fluids, flammable...control to minimize the types and quantities of pesticides used at the installation (BAFB 2005). No pesticides, insecticides, or herbicides are

  11. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  12. Feasibility study for the development and marketing of magnesium seats for motor coaches and other modes of public transit

    Energy Technology Data Exchange (ETDEWEB)

    Bergeron, F. [IC-2 Technologies Inc., Quebec City, PQ (Canada); Audet, J.F. [J-F Audet Courtier Stratege, Carignan, PQ (Canada)

    2004-06-01

    Magnesium is currently used for seats in many minivans and luxury cars, as well as in some high speed trains. This paper addresses concerns about the use of magnesium in manufacturing seats for public transit vehicles. This paper aimed to validate the feasibility of magnesium and/or aluminum passenger seats and determine if they met weight and cost reduction objectives currently set by the public transportation industry. An assessment of the North American bus and motor coach market was made, and passenger seat design standards were reviewed. Additionally, magnesium samples were tested to ensure industry standards for material flammability and toxic fumes emissions during exposure to intense heat. Corrosion testing and a comparison with automobile industry tests were made. A number of manufacturing case studies were conducted, including life-cycle costs and comparisons with the manufacture of traditional steel seats. It was concluded that a lighter-weight seat is both technically possible and economically viable. In terms of flammability, magnesium seats met all required industry standards, and when combined with excellent seat design, increased the safety of seat occupants projected forward during collisions. In addition, magnesium's ability to absorb vibration was seen as a substantial benefit in terms of passenger comfort. In terms of manufacturing cost alone, a magnesium-aluminum hybrid was recommended. 15 refs., 25 tabs., 24 figs.

  13. Using bomb calorimetry for determination of risk indices of wildfires originating from pine residues

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Regueira, L.; Rodriguez Anon, J.A.; Proupin Castineiras, J.; Vilanova Diz, A.; Romero Garcia, A. [Departamento de Fisica Aplicada, Facultade de Fisica, Universidade de Santiago de Compostela, Campus Sur, 15782 , A Coruna Santiago de Compostela (Spain)

    2002-10-19

    Pine trees, mainly Pinus pinaster Aiton, now cover 640,000ha of the forest occupied surface in Galicia. The possibility of using the residues originating from pine tree exploitation as an alternative energy source could yield to gross benefit around 2.8x10{sup 8} euros per year, together with ecological advantages.The object of the present study is the evaluation of the energy contained in these residues through the measurement of their caloric values using a static bomb calorimeter. At the same time, flammabilities were measured by a standard epiradiator thus allowing the calculation of risk indices. This latter is very important to fight and prevent the start and spreading of forest fires.Elementary chemical composition was also determined using an elementary chemical analyser. Biological and bioclimatic parameters, which are very useful for the evaluation of caloric values and flammabilities over the year, were used for discussion of results.

  14. A Study of the Curing and Flammability Properties of Bisphenol A Epoxy Diacrylate Resin Utilizing a Novel Flame Retardant Monomer, bis[di-acryloyloxyethyl]-p-tert-butyl-phenyl Phosphate

    Directory of Open Access Journals (Sweden)

    Syang-Peng Rwei

    2017-02-01

    Full Text Available A UV-curable, flame-retardant monomer, DAPP (bis[di-acryloyloxyethyl]-p-tert-butyl-phenyl-phosphate, was synthesized based on BPDCP (4-tert-butylphenyl-dichloro phosphate and HEA (2-hydroxy ethyl acrylate. DAPP was blended with regular bisphenol A epoxy acrylate (BAEA in various ratios to yield various phosphorus contents. The TGA-IR (thermogravimetric analyzer interface with an infrared spectrometer results demonstrate that compounding 30 mol % DAPP with BAEA significantly reduced the amount of released CO gas. In contrast, the peak intensity of CO2 is independent of phosphorus content. The limiting oxygen index (LOI, reaching the saturated value of 26, and the heat release rate (HRR measured using a cone-calorimeter, 156.43 KW/m2, confirm the saturation point when 30 mol % DAPP was compounded into BAEA. A study of the kinetics of pyrolysis reveals that Ea decreases as the phosphorus content increases. Both the TGA-IR and pyrolysis results reveal that the phosphorus compound DAPP is easily decomposed during the initial stage of burning to form an insulating layer, which inhibits further burning of the resin and the consequent release of other flammable gases.

  15. Increased Skin Dose With the Use of a Custom Mattress for Prone Breast Radiotherapy

    International Nuclear Information System (INIS)

    Becker, Stewart J.; Patel, Rakesh R.; Mackie, Thomas R.

    2007-01-01

    The purpose of this study was to measure and compare the loss of buildup to the skin of the breast in the prone position due to 2 different positioning systems during tangential external beam irradiation. Two experiments were performed; one with a standard nylon-covered foam support and another with a novel helium-filled Mylar bag support. The choice of helium-filled Mylar was to reduce the contamination to as low as possible. The experiments were designed to allow a surface dose measurement and a depth dose profile with the pads placed in the path of the beam in front of the detector. All measurements were taken using a Capintec PS-033 thin-window parallel plate ionization chamber. The standard nylon-covered foam pad caused the surface dose to rise as it got closer to the skin. When the pad was directly touching the surface, the surface dose increased by 300% compared to the result when no pad was present. This loss of buildup to the surface was similar to that of a custom bolus material. The opposite effect occurred with the use of the helium-filled Mylar bag, namely the surface dose gradually decreased as the pad got closer to the phantom. When the Mylar pad was directly touching the phantom, the surface dose was decreased by 7% compared to when no pad was present. The use of a foam pad could potentially result in a significant higher dose to the skin, resulting in an enhanced acute skin reaction. Therefore, special care should be taken in this clinical scenario and further investigation of an air- or helium-based mylar support pad should be investigated in the context of definitive breast radiation treatment

  16. 77 FR 48505 - Submission for OMB Review; Comment Request-Flammability Standards for Carpets and Rugs

    Science.gov (United States)

    2012-08-14

    ... passing test results, then only one test per year is required. For purposes of estimating burden, we have... mail/hand delivery/courier (for paper, disk, or CD-ROM submissions), preferably in five copies, to... to perform each year varies, depending upon the number of carpet styles and the annual volume of...

  17. Climate change and future wildfire in the western USA: what model projections do and don't tell us

    Science.gov (United States)

    Littell, J. S.; McKenzie, D.; Cushman, S. A.; Wan, H. Y.

    2017-12-01

    We developed statistical climate-fire models describing area burned for 70 ecosections in the western U.S. Historically, these ecosections collectively represent a gradient of climate-fire relationships from purely fuel limited (characterized by antecedent positive water balance anomalies and/or negative energy balance anomalies) to purely flammability limited (characterized by antecedent negative water balance anomalies and/or positive energy balance anomalies). Sixty-eight ecosection linear models included significant climate predictors, and 56 ecosections satisfied regression diagnostics, yielding acceptable climate-fire models. There is considerable diversity in seasonality, dominant variables, and prevalence of lagged climatic terms in the climate-fire regression models, indicating variation in mechanisms of climate-fire linkages across ecosystems. This diversity, however, is not random - there is a clear pattern in the fuzzy set membership of the relative dominance of regression predictor variables. This pattern defines a fuel-flammability gradient of limitations, with a tendency toward warm season drought on the flammability end and a tendency toward antecedent moisture on the fuel end. Projected area burned under a multi-model composite future climate scenarios varies, with increasing area burned in 41 ecosections in the West by 2030-2059 (median 132% among 10 purely flammability limited ecosections, median 240% among 25 flammability limited systems with a fuel limitation component, and median 43% among 6 systems with equal control) but decreasing (median -119% among 13 fuel limited systems with a flammability component). For the period 2070-2099, the projected area burned increases much more in the flammability (769%) and flammability-fuel hybrid (442%) systems than those with joint control (139%), and continues to decrease (-178%) in fuel-flammability hybrid systems. Filtering the projected results with fire rotation limits projections biased high by the

  18. 16 CFR 1009.3 - Policy on imported products, importers, and foreign manufacturers.

    Science.gov (United States)

    2010-01-01

    ...: The Federal Hazardous Substances Act (15 U.S.C. 1261), the Flammable Fabrics Act (15 U.S.C. 1191), the... Federal Hazardous Substances Act (15 U.S.C. 1261 et seq.), the Flammable Fabrics Act (15 U.S.C. 1191 et... by the Commission do not specifically require certificates; however, both the Flammable Fabrics Act...

  19. Automated assessment of mobility in bedridden patients.

    Science.gov (United States)

    Bennett, Stephanie; Goubran, Rafik; Rockwood, Kenneth; Knoefel, Frank

    2013-01-01

    Immobility in older patients is a costly problem for both patients and healthcare workers. The Hierarchical Assessment of Balance and Mobility (HABAM) is a clinical tool able to assess immobile patients and predict morbidity, yet could become more reliable and informative through automation. This paper proposes an algorithm to automatically determine which of three enacted HABAM scores (associated with bedridden patients) had been performed by volunteers. A laptop was used to gather pressure data from three mats placed on a standard hospital bed frame while five volunteers performed three enactments each. A system of algorithms was created, consisting of three subsystems. The first subsystem used mattress data to calculate individual sensor sums and eliminate the weight of the mattress. The second subsystem established a baseline pressure reading for each volunteer and used percentage change to identify and distinguish between two enactments. The third subsystem used calculated weight distribution ratios to determine if the data represented the remaining enactment. The system was tested for accuracy by inputting the volunteer data and recording the assessment output (a score per data set). The system identified 13 of 15 sets of volunteer data as expected. Examination of these results indicated that the two sets of data were not misidentified; rather, the volunteers had made mistakes in performance. These results suggest that this system of algorithms is effective in distinguishing between the three HABAM score enactments examined here, and emphasizes the potential for pervasive computing to improve traditional healthcare.

  20. 78 FR 48224 - Lac-Mégantic Railroad Accident Discussion and DOT Safety Recommendations

    Science.gov (United States)

    2013-08-07

    ..., Class 3 flammable liquid or combustible liquid, Class 1.1 or 1.2 explosive, or hazardous substance... crude oil will remain high.\\3\\ Both ethanol and crude oil are classified as Class 3 flammable or... flammable liquids such as petroleum crude oil with a flash point at or above 38 [deg]C (100[emsp14][deg]F...

  1. 40 CFR 261.21 - Characteristic of ignitability.

    Science.gov (United States)

    2010-07-01

    ... 130 °F; or any liquid flammable material having a vapor pressure exceeding 40 p.s.i. absolute at 100... flammable mixture or the flammable range with air is wider than 12 percent regardless of the lower limit.... (4) It is an oxidizer. An oxidizer for the purpose of this subchapter is a substance such as a...

  2. Hock lesions and free-stall design.

    Science.gov (United States)

    Weary, D M; Taszkun, I

    2000-04-01

    We compared the prevalence and severity of skin lesions on the hocks of lactating dairy cows in southern British Columbia, comparing 20 farms using three common bedding surfaces: sawdust, sand, and geotextile mattresses. Skin lesions were scored at five positions on the hock. For each position we noted if the lesion showed inflammatory attributes, and then assigned a severity score. Of the 1752 lactating cows scored, 1267 cows (73%) had at least one hock lesion. Of those cows with lesions, 87% had lesions on both legs, 76% had lesions on more than one location on the hock, and 78% had a lesion of at least moderate severity (i.e., evidence of skin breakage or an area of hair loss >10 cm2). Lesions were most prevalent on farms that used geotextile mattresses (91% of cows) and least common on farms that used sand (24% of cows). Moreover, lesions on cows from farms using mattresses were more numerous and more severe than those on cows from sand-bedded farms. The prevalence and severity of lesions on farms using sawdust was intermediate. Lesions also varied in relation to location on the hock. For farms using geotextile mattresses, lesions were more common and more severe on the lateral surfaces of both the tuber calcis and the tarsal joint. On farms using sawdust, lesions were common on the dorsal surface of the tuber calcis and the lateral surfaces of both the tuber calcis and the tarsal joint. Lesions were rare on all five positions for cows from sand-bedded farms. Among the 10 farms sampled using sawdust, we found a significant negative relationship between the length of the stall and severity of lesions. For cows with lesions, the number and severity of lesions increased with age.

  3. Biomechanical evaluation of knotless anatomical double-layer double-row rotator cuff repair: a comparative ex vivo study.

    Science.gov (United States)

    Hepp, Pierre; Osterhoff, Georg; Engel, Thomas; Marquass, Bastian; Klink, Thomas; Josten, Christoph

    2009-07-01

    The layered configuration of the rotator cuff tendon is not taken into account in classic rotator cuff tendon repair techniques. The mechanical properties of (1) the classic double-row technique, (2) a double-layer double-row (DLDR) technique in simple suture configuration, and (3) a DLDR technique in mattress suture configuration are significantly different. Controlled laboratory study. Twenty-four sheep shoulders were assigned to 3 repair groups of full-thickness infraspinatus tears: group 1, traditional double-row repair; group 2, DLDR anchor repair with simple suture configuration; and group 3, DLDR knotless repair with mattress suture configuration. After ultrasound evaluation of the repair, each specimen was cyclically loaded with 10 to 100 N for 50 cycles. Each specimen was then loaded to failure at a rate of 1 mm/s. There were no statistically significant differences among the 3 testing groups for the mean footprint area. The cyclic loading test revealed no significant difference among the 3 groups with regard to elongation. For the load-to-failure test, groups 2 and 3 showed no differences in ultimate tensile load when compared with group 1. However, when compared to group 2, group 3 was found to have significantly higher values regarding ultimate load, ultimate elongation, and energy absorbed. The DLDR fixation techniques may provide strength of initial repair comparable with that of commonly used double-row techniques. When compared with the knotless technique with mattress sutures, simple suture configuration of DLDR repair may be too weak. Knotless DLDR rotator cuff repair may (1) restore the footprint by the use of double-row principles and (2) enable restoration of the shape and profile. Double-layer double-row fixation in mattress suture configuration has initial fixation strength comparable with that of the classic double-row fixation and so may potentially improve functional results of rotator cuff repair.

  4. Mechanisms of gas bubble retention and release: results for Hanford Waste Tanks 241-S-102 and 241-SY-103 and single-shell tank simulants

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, P.A.; Rassat, S.D.; Bredt, P.R.; Konynenbelt, J.H.; Tingey, S.M.; Mendoza, D.P.

    1996-09-01

    Research at Pacific Northwest National Laboratory (PNNL) has probed the physical mechanisms and waste properties that contribute to the retention and release of flammable gases from radioactive waste stored in underground tanks at Hanford. This study was conducted for Westinghouse Hanford Company as part of the PNNL Flammable Gas Project. The wastes contained in the tanks are mixes of radioactive and chemical products, and some of these wastes are known to generate mixtures of flammable gases, including hydrogen, nitrous oxide, and ammonia. Because these gases are flammable, their retention and episodic release pose a number of safety concerns.

  5. Mechanisms of gas bubble retention and release: results for Hanford Waste Tanks 241-S-102 and 241-SY-103 and single-shell tank simulants

    International Nuclear Information System (INIS)

    Gauglitz, P.A.; Rassat, S.D.; Bredt, P.R.; Konynenbelt, J.H.; Tingey, S.M.; Mendoza, D.P.

    1996-09-01

    Research at Pacific Northwest National Laboratory (PNNL) has probed the physical mechanisms and waste properties that contribute to the retention and release of flammable gases from radioactive waste stored in underground tanks at Hanford. This study was conducted for Westinghouse Hanford Company as part of the PNNL Flammable Gas Project. The wastes contained in the tanks are mixes of radioactive and chemical products, and some of these wastes are known to generate mixtures of flammable gases, including hydrogen, nitrous oxide, and ammonia. Because these gases are flammable, their retention and episodic release pose a number of safety concerns

  6. METHODOLOGY AND CALCULATIONS FOR THE ASSIGNMENT OF WASTE GROUPS FOR THE LARGE UNDERGROUND WASTE STORAGE TANKS AT THE HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    WEBER RA

    2009-01-16

    The Hanford Site contains 177 large underground radioactive waste storage tanks (28 double-shell tanks and 149 single-shell tanks). These tanks are categorized into one of three waste groups (A, B, and C) based on their waste and tank characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement gas release event. Assignments of waste groups to the 177 double-shell tanks and single-shell tanks, as reported in this document, are based on a Monte Carlo analysis of three criteria. The first criterion is the headspace flammable gas concentration following release of retained gas. This criterion determines whether the tank contains sufficient retained gas such that the well-mixed headspace flammable gas concentration would reach 100% of the lower flammability limit if the entire tank's retained gas were released. If the volume of retained gas is not sufficient to reach 100% of the lower flammability limit, then flammable conditions cannot be reached and the tank is classified as a waste group C tank independent of the method the gas is released. The second criterion is the energy ratio and considers whether there is sufficient supernatant on top of the saturated solids such that gas-bearing solids have the potential energy required to break up the material and release gas. Tanks that are not waste group C tanks and that have an energy ratio < 3.0 do not have sufficient potential energy to break up material and release gas and are assigned to waste group B. These tanks are considered to represent a potential induced flammable gas release hazard, but no spontaneous buoyant displacement flammable gas release hazard. Tanks that are not waste group C tanks and have an energy ratio {ge} 3.0, but that pass the third criterion (buoyancy ratio < 1.0, see below) are also assigned to waste group B. Even though the designation as

  7. METHODOLOGY AND CALCULATIONS FOR THE ASSIGNMENT OF WASTE GROUPS FOR THE LARGE UNDERGROUND WASTE STORAGE TANKS AT THE HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    FOWLER KD

    2007-12-27

    This document categorizes each of the large waste storage tanks into one of several categories based on each tank's waste characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement event. Revision 7 is the annual update of the calculations of the flammable gas Waste Groups for DSTs and SSTs. The Hanford Site contains 177 large underground radioactive waste storage tanks (28 double-shell tanks and 149 single-shell tanks). These tanks are categorized into one of three waste groups (A, B, and C) based on their waste and tank characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement gas release event. Assignments of waste groups to the 177 double-shell tanks and single-shell tanks, as reported in this document, are based on a Monte Carlo analysis of three criteria. The first criterion is the headspace flammable gas concentration following release of retained gas. This criterion determines whether the tank contains sufficient retained gas such that the well-mixed headspace flammable gas concentration would reach 100% of the lower flammability limit if the entire tank's retained gas were released. If the volume of retained gas is not sufficient to reach 100% of the lower flammability limit, then flammable conditions cannot be reached and the tank is classified as a waste group C tank independent of the method the gas is released. The second criterion is the energy ratio and considers whether there is sufficient supernatant on top of the saturated solids such that gas-bearing solids have the potential energy required to break up the material and release gas. Tanks that are not waste group C tanks and that have an energy ratio < 3.0 do not have sufficient

  8. 49 CFR 173.115 - Class 2, Divisions 2.1, 2.2, and 2.3-Definitions.

    Science.gov (United States)

    2010-10-01

    ... substances of Class 8, PG I are forbidden from transportation in an aerosol container. (7) Flammable... 2.1, 2.2, and 2.3—Definitions. (a) Division 2.1 (Flammable gas). For the purpose of this subchapter, a flammable gas (Division 2.1) means any material which is a gas at 20 °C (68 °F) or less and 101.3...

  9. The influence of household pets on the composition and quantity of allergenic mite fauna within Irish homes: a preliminary investigation.

    Science.gov (United States)

    Clarke, D; Dix, E; Liddy, S; Gormally, M; Byrne, M

    2016-03-01

    Allergenic mites are responsible for inducing hypersensitive reactions in genetically predisposed people worldwide. Mites in dust from 30 Irish homes with pets (dogs, n = 23; cats, n = 7) were compared with those in 30 homes without pets. House dust mites constituted 78% of all mites recorded, with Dermatophagoides pteronyssinus (Acariformes: Pyroglyphidae) representing 57-72% of mites in furniture and mattresses in both home types compared with only 22% of mites in pet beds. Although storage mites accounted for just 13% of all mites recorded, they represented 46% of mites recorded in pet beds. Median levels of the dust mite allergen Der p 1 (µg/g) in dust samples from mattresses in homes without pets were significantly greater than in mattresses from homes with pets, reflecting the greater densities of D. pteronyssinus found in the former home category. Mite species richness was greater in homes with pets (17 species) than in homes without pets (13 species). This suggests that although the presence of pets can result in a wider variety of epidemiologically important mite species within households, increased competition among mite species may result in a more balanced mite fauna in the home, inhibiting the dominance of any one species and hence lowering allergen-associated risks. © 2015 The Royal Entomological Society.

  10. House dust-mite allergen exposure is associated with serum specific IgE but not with respiratory outcomes.

    Science.gov (United States)

    Bakolis, I; Heinrich, J; Zock, J P; Norbäck, D; Svanes, C; Chen, C M; Accordini, S; Verlato, G; Olivieri, M; Jarvis, D

    2015-06-01

    Exposure to house dust has been associated with asthma in adults, and this is commonly interpreted as a direct immunologic response to dust-mite allergens in those who are IgE sensitized to house dust-mite. Mattress house dust-mite concentrations were measured in a population-based sample of 2890 adults aged between 27 and 56 years living in 22 centers in 10 countries. Generalized linear mixed models were employed to explore the association of respiratory symptoms with house dust-mite concentrations, adjusting for individual and household confounders. There was no overall association of respiratory outcomes with measured house dust-mite concentrations, even in those who reported they had symptoms on exposure to dust and those who had physician-diagnosed asthma. However, there was a positive association of high serum specific IgE levels to HDM (>3.5 kUA /l) with mattress house dust-mite concentrations and a negative association of sensitization to cat with increasing house dust-mite concentrations. In conclusion, there was no evidence that respiratory symptoms in adults were associated with exposure to house dust-mite allergen in the mattress, but an association of house mite with strong sensitization was observed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Vocational High School Effectiveness Standard ISO 9001: 2008 for Achievement Content Standards, Standard Process and Competency Standards Graduates

    Directory of Open Access Journals (Sweden)

    Yeni Ratih Pratiwi

    2014-06-01

    Full Text Available Efektivitas Sekolah Menengah Kejuruan Berstandar ISO 9001:2008 terhadap Pencapaian Standar Isi, Standar Proses dan Standar Kompetensi Lulusan Abstract: The purpose of this study was to determine differences in the effectiveness of the achievement of the content standards, process standards, and competency standards in vocational already standard ISO 9001: 2008 with CMS that has not been standardized ISO 9001: 2008 both in public schools and private schools. Data collection using the questionnaire enclosed Likert scale models. Analysis of data using one-way ANOVA using SPSS. The results showed: (1 there is no difference in effectiveness between public SMK ISO standard ISO standards with private SMK (P = 0.001; (2 there are differences in the effectiveness of public SMK SMK ISO standards with ISO standards have not (P = 0.000; (3 there are differences in the effectiveness of public SMK ISO standards with private vocational yet ISO standards (P = 0.000; (4 there are differences in the effectiveness of the private vocational school with vocational standard ISO standard ISO country has not (P = 0.015; (5 there are differences in the effectiveness of the private vocational bertandar ISO with private vocational yet standardized ISO (P = 0.000; (6 there was no difference in the effectiveness of public SMK has not been standardized by the ISO standard ISO private SMK yet. Key Words: vocational high school standards ISO 9001: 2008, the standard content, process standards, competency standards Abstrak: Tujuan penelitian ini untuk mengetahui perbedaan efektivitas pencapaian standar isi, standar proses, dan standar kompetensi lulusan pada SMK yang sudah berstandar ISO 9001:2008 dengan SMK yang belum berstandar ISO 9001:2008 baik pada sekolah negeri maupun sekolah swasta. Pengumpulan data menggunakan kuisioner tertutup model skala likert. Analisis data menggunakan ANOVA one way menggunakan program SPSS. Hasil penelitian menunjukkan: (1 ada perbedaan

  12. Implementing process safety management in gas processing operations

    International Nuclear Information System (INIS)

    Rodman, D.L.

    1992-01-01

    The Occupational Safety and Health Administration (OSHA) standard entitled Process Safety Management of Highly Hazardous Chemicals; Explosives and Blasting Agents was finalized February 24, 1992. The purpose of the standard is to prevent or minimize consequences of catastrophic releases of toxic, flammable, or explosive chemicals. OSHA believes that its rule will accomplish this goal by requiring a comprehensive management program that integrates technologies, procedures, and management practices. Gas Processors Association (GPA) member companies are significantly impacted by this major standard, the requirements of which are extensive and complex. The purpose of this paper is to review the requirements of the standard and to discuss the elements to consider in developing and implementing a viable long term Process Safety Management Program

  13. Telemetry Standards, RCC Standard 106-17. Chapter 3. Frequency Division Multiplexing Telemetry Standards

    Science.gov (United States)

    2017-07-01

    Standard 106-17 Chapter 3, July 2017 3-5 Table 3-4. Constant-Bandwidth FM Subcarrier Channels Frequency Criteria\\Channels: A B C D E F G H Deviation ...Telemetry Standards , RCC Standard 106-17 Chapter 3, July 2017 3-i CHAPTER 3 Frequency Division Multiplexing Telemetry Standards Acronyms...Frequency Division Multiplexing Telemetry Standards ................................ 3-1 3.1 General

  14. A study on cow comfort and risk for lameness and mastitis in relation to different types of bedding materials.

    Science.gov (United States)

    van Gastelen, S; Westerlaan, B; Houwers, D J; van Eerdenburg, F J C M

    2011-10-01

    The aim was to obtain data regarding the effects of 4 freestall bedding materials (i.e., box compost, sand, horse manure, and foam mattresses) on cow comfort and risks for lameness and mastitis. The comfort of freestalls was measured by analyzing the way cows entered the stalls, the duration and smoothness of the descent movement, and the duration of the lying bout. The cleanliness of the cows was evaluated on 3 different body parts: (1) udder, (2) flank, and (3) lower rear legs, and the bacteriological counts of the bedding materials were determined. The combination of the cleanliness of the cows and the bacteriological count of the bedding material provided an estimate of the risk to which dairy cows are exposed in terms of intramammary infections. The results of the hock assessment revealed that the percentage of cows with healthy hocks was lower (20.5 ± 6.7), the percentage of cows with both damaged and swollen hocks was higher (26.8 ± 3.2), and the severity of the damaged hock was higher (2.32 ± 0.17) on farms using foam mattresses compared with deep litter materials [i.e., box compost (64.0 ± 10.4, 3.5 ± 4.7, 1.85 ± 0.23, respectively), sand (54.6 ± 8.2, 2.0 ± 2.8, 1.91 ± 0.09, respectively), and horse manure (54.6 ± 4.5, 5.5 ± 5.4, 1.85 ± 0.17, respectively)]. In addition, cows needed more time to lie down (140.2 ± 84.2s) on farms using foam mattresses compared with the deep litter materials sand and horse manure (sand: 50.1 ± 31.6s, horse manure: 32.9 ± 0.8s). Furthermore, the duration of the lying bout was shorter (47.9 ± 7.4 min) on farms using foam mattresses compared to sand (92.0 ± 12.9 min). These results indicate that deep litter materials provide a more comfortable lying surface compared with foam mattresses. The 3 deep litter bedding materials differed in relation to each other in terms of comfort and their estimate of risk to which cows were exposed in terms of intramammary infections [box compost: 17.8 cfu (1.0(4)) ± 19.4/g

  15. Gas release during salt well pumping: model predictions and comparisons to laboratory experiments

    International Nuclear Information System (INIS)

    Peurrung, L.M.; Caley, S.M.; Bian, E.Y.; Gauglitz, P.A.

    1996-09-01

    The Hanford Site has 149 single-shell tanks (SSTs) containing radioactive wastes that are complex mixes of radioactive and chemical products. Some of these wastes are known to generate mixtures of flammable gases, including hydrogen, nitrous oxide, and ammonia. Nineteen of these SSTs have been placed on the Flammable Gas Watch List (FGWL) because they are known or suspected, in all but one case, to retain these flammable gases. Salt well pumping to remove the interstitial liquid from SSTs is expected to cause the release of much of the retained gas, posing a number of safety concerns. Research at the Pacific Northwest National Laboratory (PNNL) has sought to quantify the release of flammable gases during salt well pumping operations. This study is being conducted for Westinghouse Hanford Company as part of the PNNL Flammable Gas Project. Understanding and quantifying the physical mechanisms and waste properties that govern gas release during salt well pumping will help to resolve the associated safety issues

  16. Hazardous Materials Hazard Analysis, Portland, Oregon.

    Science.gov (United States)

    1981-06-01

    poisons and flammables are found in all agriculture and garden supply shops, automotive repair facilities, retail paint and hardware stores, etc...Peroxide rompressed Gases and Welding 4 NON-FLAMMABLE GAS: Surpplies Liquid Nitrogen FLAMMABLE GAS: Acetylene Hydrogen Propane Propylene Oxide OTHER...this small community said Sunday and where the water and the chemicals and 16,000 bags of chemicals were de- that he was upset with the way officials

  17. Standards for Standardized Logistic Regression Coefficients

    Science.gov (United States)

    Menard, Scott

    2011-01-01

    Standardized coefficients in logistic regression analysis have the same utility as standardized coefficients in linear regression analysis. Although there has been no consensus on the best way to construct standardized logistic regression coefficients, there is now sufficient evidence to suggest a single best approach to the construction of a…

  18. The Safety of Hospital Beds: Ingress, Egress, and In-Bed Mobility.

    Science.gov (United States)

    Morse, Janice M; Gervais, Pierre; Pooler, Charlotte; Merryweather, Andrew; Doig, Alexa K; Bloswick, Donald

    2015-01-01

    To explore the safety of the standard and the low hospital bed, we report on a microanalysis of 15 patients' ability to ingress, move about the bed, and egress. The 15 participants were purposefully selected with various disabilities. Bed conditions were randomized with side rails up or down and one low bed with side rails down. We explored the patients' use of the side rails, bed height, ability to lift their legs onto the mattress, and ability to turn, egress, and walk back to the chair. The standard bed was too high for some participants, both for ingress and egress. Side rails were used by most participants when entering, turning in bed, and exiting. We recommend that side rails be reconsidered as a means to facilitate in-bed movement, ingress, and egress. Furthermore, single deck height settings for all patients are not optimal. Low beds as a safety measure must be re-evaluated.

  19. The Safety of Hospital Beds

    Science.gov (United States)

    Gervais, Pierre; Pooler, Charlotte; Merryweather, Andrew; Doig, Alexa K.; Bloswick, Donald

    2015-01-01

    To explore the safety of the standard and the low hospital bed, we report on a microanalysis of 15 patients’ ability to ingress, move about the bed, and egress. The 15 participants were purposefully selected with various disabilities. Bed conditions were randomized with side rails up or down and one low bed with side rails down. We explored the patients’ use of the side rails, bed height, ability to lift their legs onto the mattress, and ability to turn, egress, and walk back to the chair. The standard bed was too high for some participants, both for ingress and egress. Side rails were used by most participants when entering, turning in bed, and exiting. We recommend that side rails be reconsidered as a means to facilitate in-bed movement, ingress, and egress. Furthermore, single deck height settings for all patients are not optimal. Low beds as a safety measure must be re-evaluated. PMID:28462302

  20. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  1. DOE technical standards list. Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  2. Back Pain

    Science.gov (United States)

    ... addition, there doesn't appear to be one type of mattress that's best for people with back pain. It's probably a ... of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  3. 77 FR 43542 - Cost Accounting Standards: Cost Accounting Standards 412 and 413-Cost Accounting Standards...

    Science.gov (United States)

    2012-07-25

    ... rule that revised Cost Accounting Standard (CAS) 412, ``Composition and Measurement of Pension Cost... Accounting Standards: Cost Accounting Standards 412 and 413--Cost Accounting Standards Pension Harmonization Rule AGENCY: Cost Accounting Standards Board, Office of Federal Procurement Policy, Office of...

  4. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    Science.gov (United States)

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (Pprefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  5. How to remove a chest drain.

    Science.gov (United States)

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  6. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This technical standards list (TSL) was prepared for use by personnel involved in the selection and use of US DOE technical standards and other government and non-government standards. This TSL provides listings of current DOE technical standards, non-government standards that have been adopted by DOE, other government documents in which DOE has a recorded interest, and cancelled DOE technical standards. Standards are indexed by type in the appendices to this document. Definitions of and general guidance for the use of standards are also provided.

  7. Spine alignment in men during lateral sleep position: experimental study and modeling

    Directory of Open Access Journals (Sweden)

    Leilnahari Karim

    2011-11-01

    Full Text Available Abstract Background A proper sleep system can affect the spine support in neutral position. Most of the previous studies in scientific literature have focused on the effects of customary mattresses on the spinal alignment. To keep the spine in optimal alignment, one can use sleep surfaces with different zonal elasticity, the so called custom-made arrangements. The required stiffness of a sleep surface for each individual can be obtained by changing this arrangement applying the experimental method and modeling. Methods In experimental part, the coordinate positions of the markers mounted on the spinous processes of the vertebrae of 25 male volunteers were registered in frontal plane through the optical tracking method and so the spinal alignment was obtained in lateral sleep position on soft and firm surfaces and on the best custom-made arrangement. Thereupon the π-P8 angles were extracted from these alignments and then were compared with each other. In modeling part the anthropometric data of four different types of volunteers were used. And then the models built in BRG.LifeMOD (ver. 2007, Biomechanics Research Group, Inc., USA based on these data and in accordance with the experimental tests, were analyzed. Results The one way ANOVA statistical model and the post hoc tests showed a significant difference in the π-P8 angles between soft & custom-made and soft & firm mattresses at the p = 0.001 level and between firm & soft mattresses at the p = 0.05 level. In modeling part, the required stiffness of the sleep surface for four weight-dimensional groups was acquired quantitatively. Conclusions The mattress with a custom-made arrangement is a more appropriate choice for heavier men with pronounced body contour. After data fitting, it was observed that the variations of spinal alignment obtained from both methods have the same trend. Observing the amount of required stiffness obtained for the sleep surface, can have a significant effect on

  8. 41 CFR 50-204.72 - Safe practices for welding and cutting on containers which have held combustibles.

    Science.gov (United States)

    2010-07-01

    ... combustibles. Welding or cutting, or both, on containers which have held flammable or combustible solids, liquids, or gases, or have contained substances which may produce flammable vapors or gases will not be...

  9. Controlling Bed Bugs Using Integrated Pest Management (IPM)

    Science.gov (United States)

    Several non-chemical methods can help control an infestation, such as heat treatment or freezing, or mattress and box spring encasements. When using a pesticide, follow label directions carefully and check for EPA registration.

  10. The International Standards Organisation offshore structures standard

    International Nuclear Information System (INIS)

    Snell, R.O.

    1994-01-01

    The International Standards Organisation has initiated a program to develop a suite of ISO Codes and Standards for the Oil Industry. The Offshore Structures Standard is one of seven topics being addressed. The scope of the standard will encompass fixed steel and concrete structures, floating structures, Arctic structures and the site specific assessment of mobile drilling and accommodation units. The standard will use as base documents the existing recommended practices and standards most frequently used for each type of structure, and will develop them to incorporate best published and recognized practice and knowledge where it provides a significant improvement on the base document. Work on the Code has commenced under the direction of an internationally constituted sub-committee comprising representatives from most of the countries with a substantial offshore oil and gas industry. This paper outlines the background to the code and the format, content and work program

  11. SAFETY ENGINEERING FOR THE RELATIVISTIC HEAVY ION COLLIDER AT THE BROOKHAVEN NATIONAL LABORATORY

    International Nuclear Information System (INIS)

    Musolino, S.V.; Kane, S.F.; Levesque, J.W.

    1999-01-01

    THERE ARE ONLY A FEW OTHER HIGH ENERGY PARTICLE ACCELERATORS LIKE RHIC IN THE WORLD. THEREFORE, THE DESIGNERS OF THE MACHINE DO NOT ALWAYS HAVE CONSENSUS DESIGN STANDARDS AND REGULATORY GUIDANCE AVAILABLE TO ESTABLISH THE ENGINEERING PARAMETERS FOR SAFETY. SOME OF THE AREAS WHERE STANDARDS ARE NOT AVAILABLE RELATE TO THE CRYOGENIC SYSTEM, CONTAINMENT OF LARGE VOLUMES OF FLAMMABLE GAS IN FRAGILE VESSELS IN THE EXPERIMENTAL APPARATUS AND MITIGATION OF A DESIGN BASIS ACCIDENT WITH A STORED PARTICLE BEAM. UNIQUE BUT EQUIVALENT SAFETY ENGINEERING MUST BE DETERMINED. SPECIAL DESIGN CRITERIA FOR PROMPT RADIATION WERE DEVELOPED TO PROVIDE GUIDANCE FOR THE DESIGN OF RADIATION SHIELDING

  12. Ventilation in homes infested by house-dust mites.

    Science.gov (United States)

    Sundell, J; Wickman, M; Pershagen, G; Nordvall, S L

    1995-02-01

    Thirty single-family homes with either high (> or = 2000 ng/g) or low (< or = 1000 ng/g) house-dust mite (HDM) allergen levels in mattress dust were examined for ventilation, thermal climate, and air quality (formaldehyde and total volatile organic compounds (TVOC). Elevated concentrations of HDM allergen in mattress and floor dust were associated with the difference in absolute humidity between indoor and outdoor air, as well as with low air-change rates of the home, particularly the bedroom. No correlation was found between concentration of TVOC or formaldehyde in bedroom air and HDM allergen concentration. In regions with a cold winter climate, the air-change rate of the home and the infiltration of outdoor air into the bedroom appear to be important for the infestation of HDM.

  13. Status of conversion of DOE standards to non-Government standards

    Energy Technology Data Exchange (ETDEWEB)

    Moseley, H.L.

    1992-07-01

    One major goal of the DOE Technical Standards Program is to convert existing DOE standards into non-Government standards (NGS's) where possible. This means that a DOE standard may form the basis for a standards-writing committee to produce a standard in the same subject area using the non-Government standards consensus process. This report is a summary of the activities that have evolved to effect conversion of DOE standards to NGSs, and the status of current conversion activities. In some cases, all requirements in a DOE standard will not be incorporated into the published non-Government standard because these requirements may be considered too restrictive or too specific for broader application by private industry. If requirements in a DOE standard are not incorporated in a non-Government standard and the requirements are considered necessary for DOE program applications, the DOE standard will be revised and issued as a supplement to the non-Government standard. The DOE standard will contain only those necessary requirements not reflected by the non-Government standard. Therefore, while complete conversion of DOE standards may not always be realized, the Department's technical standards policy as stated in Order 1300.2A has been fully supported in attempting to make maximum use of the non-Government standard.

  14. Status of conversion of DOE standards to non-Government standards

    Energy Technology Data Exchange (ETDEWEB)

    Moseley, H.L.

    1992-07-01

    One major goal of the DOE Technical Standards Program is to convert existing DOE standards into non-Government standards (NGS`s) where possible. This means that a DOE standard may form the basis for a standards-writing committee to produce a standard in the same subject area using the non-Government standards consensus process. This report is a summary of the activities that have evolved to effect conversion of DOE standards to NGSs, and the status of current conversion activities. In some cases, all requirements in a DOE standard will not be incorporated into the published non-Government standard because these requirements may be considered too restrictive or too specific for broader application by private industry. If requirements in a DOE standard are not incorporated in a non-Government standard and the requirements are considered necessary for DOE program applications, the DOE standard will be revised and issued as a supplement to the non-Government standard. The DOE standard will contain only those necessary requirements not reflected by the non-Government standard. Therefore, while complete conversion of DOE standards may not always be realized, the Department`s technical standards policy as stated in Order 1300.2A has been fully supported in attempting to make maximum use of the non-Government standard.

  15. Instant standard concept for data standards development

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert; Kulcsor, Istvan Zsolt; Roes, Jasper

    2013-01-01

    This paper presents the current results of an ongoing research about a new data standards development concept. The concept is called Instant Standard referring to the pressure that is generated by shrinking the length of the standardization process. Based on this concept it is estimated that the

  16. Mechanisms of gas retention and release: Experimental results for Hanford waste tanks 241-AW-101 and 241-AN-103

    Energy Technology Data Exchange (ETDEWEB)

    Rassat, S.D.; Gauglitz, P.A.; Bredt, P.R.; Mahoney, L.A.; Forbes, S.V.; Tingey, S.M.

    1997-09-01

    The 177 storage tanks at Hanford contain a vast array of radioactive waste forms resulting, primarily, from nuclear materials processing. Through radiolytic, thermal, and other decomposition reactions of waste components, gaseous species including hydrogen, ammonia, and the oxidizer nitrous oxide are generated within the waste tanks. Many of these tanks are known to retain and periodically release quantities of these flammable gas mixtures. The primary focus of the Flammable Gas Project is the safe storage of Hanford tank wastes. To this end, we strive to develop an understanding of the mechanisms of flammable gas retention and release in Hanford tanks through laboratory investigations on actual tank wastes. These results support the closure of the Flammable Gas Unreviewed Safety Question (USQ) on the safe storage of waste tanks known to retain flammable gases and support resolution of the broader Flammable Gas Safety Issue. The overall purpose of this ongoing study is to develop a comprehensive and thorough understanding of the mechanisms of flammable gas retention and release. The first objective of the current study was to classify bubble retention and release mechanisms in two previously untested waste materials from Tanks 241-AN-103 (AN-103) and 241-AW-101 (AW-101). Results were obtained for retention mechanisms, release characteristics, and the maximum gas retention. In addition, unique behavior was also documented and compared with previously studied waste samples. The second objective was to lengthen the duration of the experiments to evaluate the role of slowing bubble growth on the retention and release behavior. Results were obtained for experiments lasting from a few hours to a few days.

  17. Mechanisms of gas retention and release: Experimental results for Hanford waste tanks 241-AW-101 and 241-AN-103

    International Nuclear Information System (INIS)

    Rassat, S.D.; Gauglitz, P.A.; Bredt, P.R.; Mahoney, L.A.; Forbes, S.V.; Tingey, S.M.

    1997-09-01

    The 177 storage tanks at Hanford contain a vast array of radioactive waste forms resulting, primarily, from nuclear materials processing. Through radiolytic, thermal, and other decomposition reactions of waste components, gaseous species including hydrogen, ammonia, and the oxidizer nitrous oxide are generated within the waste tanks. Many of these tanks are known to retain and periodically release quantities of these flammable gas mixtures. The primary focus of the Flammable Gas Project is the safe storage of Hanford tank wastes. To this end, we strive to develop an understanding of the mechanisms of flammable gas retention and release in Hanford tanks through laboratory investigations on actual tank wastes. These results support the closure of the Flammable Gas Unreviewed Safety Question (USQ) on the safe storage of waste tanks known to retain flammable gases and support resolution of the broader Flammable Gas Safety Issue. The overall purpose of this ongoing study is to develop a comprehensive and thorough understanding of the mechanisms of flammable gas retention and release. The first objective of the current study was to classify bubble retention and release mechanisms in two previously untested waste materials from Tanks 241-AN-103 (AN-103) and 241-AW-101 (AW-101). Results were obtained for retention mechanisms, release characteristics, and the maximum gas retention. In addition, unique behavior was also documented and compared with previously studied waste samples. The second objective was to lengthen the duration of the experiments to evaluate the role of slowing bubble growth on the retention and release behavior. Results were obtained for experiments lasting from a few hours to a few days

  18. Occurrence, emission and ignition of combustible strata gases in Witwatersrand gold mines and Bushveld platinum mines, and means of ameliorating related ignition and explosion hazards, Part 1: literature and technical review.

    CSIR Research Space (South Africa)

    Cook, AP

    1998-10-01

    Full Text Available 60 62 63 64 9 Terminology and abbreviations The terms combustible, flammable and inflammable, to describe gases encountered in mining, are all used commonly in literature and within the South African mining industry. The Concise Oxford English... dictionary defines them as: combustible: capable of burning inflammable: easily set on fire flammable: rarely used except in “nonflammable”. In this report combustible and flammable are used to describe gas or gases that will burn or explode in air...

  19. Energy poverty, shack fires and childhood burns

    Directory of Open Access Journals (Sweden)

    D K Kimemia

    2017-04-01

    Full Text Available Burn injuries are a persisting challenge in South Africa. Energy poverty, prevalent in under-resourced communities, is a key contributor to the problem. The energy-poor rely on solid fuels and flammable hydrocarbons, such as paraffin, for energy services. The fuels are burnt in inefficient, leaky and unstable appliances, leading to health losses from pollutant emissions, burns, and conflagrations. Within cramped informal home settings, using flammable fuels and risky combustion technologies, the situation can become devastating, especially for young children. Those who survive fiery incidents have to contend with trauma and property losses that may lead to further impoverishment. Proactive intervention strategies are required and should include the broadening of access to safe and sustainable energy. We advocate greater enforcement of home appliance standards and targeted support for the distribution of proven alternative energy technologies, such as liquefied petroleum gas and solar power. Support and advocacy from professional and citizen groups would be necessary to ensure that government prioritises the safe energy requirements of poor citizens.

  20. Compliance of Bombardier's Challenger 604 and CRJ200 to FAR25.856(a) : flame propagation of thermal/acoustic insulation materials and future trends in aircraft materials fire safety

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, W.R. [Bombardier, Montreal, PQ (Canada); Schofield, C.M.A. [Transport Canada, Ottawa, ON (Canada)

    2007-07-01

    This paper provided details of a testing program designed to ensure the compliance of Bombardier's Challenger 604 to new rules established to improve flammability standards for thermal and acoustic insulation materials. The rule applied to both pressurized and unpressurized sections of the fuselage, as well as to ducting, sound damping foams, and insulation bags. Test samples of all non-metallic insulation components were collected. Testing of the samples was conducted in a chamber with an ignition source as well as a controlled heat flux provided by a radiant panel. The new rules were discussed as well as challenges faced by industry which will have to show compliance for flame propagation requirements. Issues related to the in-service replacement of thermal and acoustic insulation materials were reviewed along with potential changes to flammability regulations. Materials used by Bombardier for compliant constructions were also listed. It was concluded that the safety of airplane occupants will be improved through compliance to new testing methods under harsher fire threat conditions, with more stringent pass and fail criteria. 15 refs., 5 figs.

  1. Status of conversion of NE standards to national consensus standards

    International Nuclear Information System (INIS)

    Jennings, S.D.

    1990-06-01

    One major goal of the Nuclear Standards Program is to convert existing NE standards into national consensus standards (where possible). This means that an NE standard in the same subject area using the national consensus process. This report is a summary of the activities that have evolved to effect conversion of NE standards to national consensus standards, and the status of current conversion activities. In some cases, all requirements in an NE standard will not be incorporated into the published national consensus standard because these requirements may be considered too restrictive or too specific for broader application by the nuclear industry. If these requirements are considered necessary for nuclear reactor program applications, the program standard will be revised and issued as a supplement to the national consensus standard. The supplemental program standard will contain only those necessary requirements not reflected by the national consensus standard. Therefore, while complete conversion of program standards may not always be realized, the standards policy has been fully supported in attempting to make maximum use of the national consensus standard. 1 tab

  2. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  3. 33 CFR 149.405 - How are fire extinguishers classified?

    Science.gov (United States)

    2010-07-01

    ... percentages of water, are of primary importance; (2) “B” for fires of flammable liquids, greases, or other thick flammable substances where a blanketing effect is essential; and (3) “C” for fires in electrical...

  4. Safety Education Resources: Childproofing Your Home

    Science.gov (United States)

    ... Kids and Babies En Español Kids and Babies - Safety Alerts Back to Safety Education Resources Air Mattresses ... Home Drowning Deaths in Spanish Kids and Babies - Safety Guides Back to Safety Education Resources Baby Safety ...

  5. Telemetry Standards, RCC Standard 106-17. Chapter 8. Digital Data Bus Acquisition Formatting Standard

    Science.gov (United States)

    2017-07-01

    incorrect word count/message and illegal mode codes are not considered bus errors. 8.6.2 Source Signal The source of data is a signal conforming to...Telemetry Standards, RCC Standard 106-17 Chapter 8, July 2017 CHAPTER 8 Digital Data Bus Acquisition Formatting Standard Acronyms...check FCS frame check sequence HDDR high-density digital recording MIL-STD Military Standard msb most significant bit PCM pulse code modulation

  6. Consistency Across Standards or Standards in a New Business Model

    Science.gov (United States)

    Russo, Dane M.

    2010-01-01

    Presentation topics include: standards in a changing business model, the new National Space Policy is driving change, a new paradigm for human spaceflight, consistency across standards, the purpose of standards, danger of over-prescriptive standards, a balance is needed (between prescriptive and general standards), enabling versus inhibiting, characteristics of success-oriented standards, characteristics of success-oriented standards, and conclusions. Additional slides include NASA Procedural Requirements 8705.2B identifies human rating standards and requirements, draft health and medical standards for human rating, what's been done, government oversight models, examples of consistency from anthropometry, examples of inconsistency from air quality and appendices of government and non-governmental human factors standards.

  7. Nonpharmacologic Interventions to Prevent Pressure Ulcers in Older Patients: An Overview of Systematic Reviews (The Software ENgine for the Assessment and optimization of drug and non-drug Therapy in Older peRsons [SENATOR] Definition of Optimal Evidence-Based Non-drug Therapies in Older People [ONTOP] Series).

    Science.gov (United States)

    Lozano-Montoya, Isabel; Vélez-Díaz-Pallarés, Manuel; Abraha, Iosief; Cherubini, Antonio; Soiza, Roy L; O'Mahony, Denis; Montero-Errasquín, Beatriz; Correa-Pérez, Andrea; Cruz-Jentoft, Alfonso J

    2016-04-01

    over usual mattresses, and very low quality evidence to support nutrition interventions in hospital settings. No recommendations on hydration, repositioning, standardized risk assessment, or multicomponent interventions can be done. In older patients at high risk to suffer PUs, high-technology and low- technology support surfaces can significantly reduce the incidence of PUs. Nutrition intervention may also have a role in preventing PUs in hospital settings. More evidence is needed to support other recommendations, which is specially lacking for repositioning. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  8. Bifurcation and extinction limit of stretched premixed flames with chain-branching intermediate kinetics and radiative loss

    Science.gov (United States)

    Zhang, Huangwei; Chen, Zheng

    2018-05-01

    Premixed counterflow flames with thermally sensitive intermediate kinetics and radiation heat loss are analysed within the framework of large activation energy. Unlike previous studies considering one-step global reaction, two-step chemistry consisting of a chain branching reaction and a recombination reaction is considered here. The correlation between the flame front location and stretch rate is derived. Based on this correlation, the extinction limit and bifurcation characteristics of the strained premixed flame are studied, and the effects of fuel and radical Lewis numbers as well as radiation heat loss are examined. Different flame regimes and their extinction characteristics can be predicted by the present theory. It is found that fuel Lewis number affects the flame bifurcation qualitatively and quantitatively, whereas radical Lewis number only has a quantitative influence. Stretch rates at the stretch and radiation extinction limits respectively decrease and increase with fuel Lewis number before the flammability limit is reached, while the radical Lewis number shows the opposite tendency. In addition, the relation between the standard flammability limit and the limit derived from the strained near stagnation flame is affected by the fuel Lewis number, but not by the radical Lewis number. Meanwhile, the flammability limit increases with decreased fuel Lewis number, but with increased radical Lewis number. Radical behaviours at flame front corresponding to flame bifurcation and extinction are also analysed in this work. It is shown that radical concentration at the flame front, under extinction stretch rate condition, increases with radical Lewis number but decreases with fuel Lewis number. It decreases with increased radiation loss.

  9. Bug bites and stings: When to see a dermatologist

    Medline Plus

    Full Text Available ... C. Fox Award and Lectureship Grants from outside organizations Health Volunteers Overseas Grant Honorary International Society Meeting ... it under the mattress for maximum protection. Pay attention to outbreaks. Check the CDC Travel Health Notices ...

  10. Analyzing Contingency Contracting Purchases for Operation Iraqi Freedom (Unrestricted Version)

    Science.gov (United States)

    2008-01-01

    that could inform such strategic purchasing decisions. 14 We used the unique contract identification number to check for cross -organization...beds, mattresses, dressers , footlockers) Other (stools, rugs, seats, cabinets, tables, folding chairs, paintings) Generators Various power generators

  11. Bug bites and stings: When to see a dermatologist

    Medline Plus

    Full Text Available ... and closed shoes instead of sandals. For additional protection, pull your socks up over your pants and ... floor, tuck it under the mattress for maximum protection. Pay attention to outbreaks. Check the CDC Travel ...

  12. 16 CFR 1633.7 - Mattress test procedure.

    Science.gov (United States)

    2010-01-01

    ... consumption calorimetry. The calibration should follow generally accepted practices for calibration. The... Grade 10 machining practice with a well formed #53 drill bit). The holes shall point 5° out of the plane... practice with a well formed #53 drill bit). The holes shall point 5° out of the plane of the diagram in...

  13. Information draft on the development of air standards for n-heptane

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    Heptane is a colourless, volatile, flammable liquid with nine isomers, the most common being n-heptane, which has a paraffinic odour. It is an ingredient in gasoline, rubber solvents, naphtha and other petroleum solvents. It occurs almost entirely in the vapour phase, where it is degraded primarily by reaction with photochemically-produced hydroxyl radicals. Short-term exposure to n-heptane at relatively low concentration resulted in vertigo and loss of coordination. Exposure to high concentration for less than 40 minutes induced prostration and loss of reflexes prior to convulsion and death. Average ambient air concentration for n-heptane in Ontario between 1988 and 1995 was 0.81 microgram/cubic meter, as measured by Environment Canada. Currently, Ontario does not have air quality criterion for n-heptane. A review of pertinent literature from world-wide sources revealed that only the states of Michigan and New York have developed air quality guidelines specifically for n-heptane, based on occupational exposure. No human or animal data was found to be available to assess the carcinogenicity of this compound. 33 refs., 1 tab., appendix.

  14. Decommissioning standards

    International Nuclear Information System (INIS)

    Crofford, W.N.

    1980-01-01

    EPA has agreed to establish a series of environmental standards for the safe disposal of radioactive waste through participation in the Interagency Review Group on Nuclear Waste Management (IRG). One of the standards required under the IRG is the standard for decommissioning of radioactive contaminated sites, facilities, and materials. This standard is to be proposed by December 1980 and promulgated by December 1981. Several considerations are important in establishing these standards. This study includes discussions of some of these considerations and attempts to evaluate their relative importance. Items covered include: the form of the standards, timing for decommissioning, occupational radiation protection, costs and financial provisions. 4 refs

  15. 49 CFR 172.312 - Liquid hazardous materials in non-bulk packagings.

    Science.gov (United States)

    2010-10-01

    ... offered or intended for transportation by aircraft, packages containing flammable liquids in inner... offered or intended for transportation by aircraft, packages containing flammable liquids in inner... hermetically sealed inner packagings. (6) Packages containing liquid infectious substances in primary...

  16. Comparison of relative and actual chest compression depths during cardiac arrest in children, adolescents, and young adults☆

    Science.gov (United States)

    Niles, Dana E.; Nishisaki, Akira; Sutton, Robert M.; Nysæther, Jon; Eilevstjønn, Joar; Leffelman, Jessica; Maltese, Matthew R.; Arbogast, Kristy B.; Abella, Benjamin S.; Helfaer, Mark A.; Berg, Robert A.; Nadkarni, Vinay M.

    2013-01-01

    Aim Cardiopulmonary resuscitation (CPR) guidelines recommend specific chest compression (CC) target depths for children. We quantitatively describe relative anterior–posterior diameter (APD) depth, actual depth, and force of CCs during real CPR events in children. Methods CC depth and force were recorded during real CPR events in children ≥8 years using FDA-approved CC sensor. Patient chest APD was measured at conclusion of each CPR event. CC data was stratified and analyzed according to age (pre-puberty, 8–14 years; post-puberty, 15+ years). Relative (% APD) and actual CC depth, corrected for mattress deflection, were assessed and compared with American Heart Association (AHA) 2005 and 2010 pediatric CPR guidelines. Results 35 events in 32 subjects included 16,158 CCs for data analysis: 16 pre-puberty (CCs = 7484, age 11.9 ± 2 years, APD 164.6 ± 25.1 mm); 19 post-puberty (CCs = 8674, age 18.0 ± 2.7 years, APD 196.5 ± 30.4 mm). After correction for mattress deflection, 92% of CC delivered to pre-puberty were resuscitation teams were frequently <1/3 relative APD and <38 mm actual depth after mattress deflection correction, below pediatric and adult target guidelines. Mean CC actual depth and force were not significantly different in pre-puberty and post-puberty. Additional investigation to determine depth of CCs to optimize hemodynamics and outcomes is needed to inform future CPR guidelines. PMID:22079410

  17. HUBUNGAN ANTARA PERILAKU PENCEGAHAN DAN KEPATUHAN BEROBAT PENDERITA TB DI INDONESIA

    Directory of Open Access Journals (Sweden)

    Noor Edi Widya Sukoco

    2012-11-01

    Full Text Available Background: Indonesia constitutes the third highest of Tuberculosis (TB cases after India and China. One of the problem in TB control is still low of drug treatment compliance of TB patients. The objective of this study was to know the relationship between TB disease prevention behaviors with treatment compliance of TB patients in Indonesia. Methods: Data explored from National Basic Health Survey (Riskesdas 2010. The data is designed to represent provinces. Design of study is cross sectional. The population is all respondents of Riskesdas 2010, while samples were chosen aged > 5 years with Pulmonary TB, particularly the TB patients who was received medication and treated by health facilities. The number of samples are all 968 patients. Interviews were conducted by skilled interviewers. Data were processed by SPSS 15 version. Results: The behavior of respondents drying the wrong mattress have risk non-compliant treatment about 1. 64 compared with the behavior of respondents drying the right mattress (OR = 1. 64; P = 0.001; confidence interval (CI=1. 21-2.22. Likewise, low education has risk non-compliant treatment in the amount of 1.62 compared with highly educated respondents (OR= 1.62; P = 0.005; confidence interval (CI = 1.15-2.27. Conclusion: The updated data signify that analysis of drug adherence TB patients will show significantly in correlation between drug adherence with level of education, and behaviour of dry mattress. Key words: drug compliance, preventive behavior. tuberculosis

  18. 16 CFR 1605.2 - Conduct and scope of inspections.

    Science.gov (United States)

    2010-01-01

    ... Section 1605.2 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS INVESTIGATIONS, INSPECTIONS AND INQUIRIES PURSUANT TO THE FLAMMABLE FABRICS ACT Procedures for Investigations... any product, fabric, or related material and all pertinent equipment, materials, substances, products...

  19. Probabilistic assessment of night pumping operation of flammable fluids and pressure testing with maritime diesel; Analise probabilisica de seguranca para as operacoes de bombeio noturno de inflamaveis e teste de pressao com diesel maritimo

    Energy Technology Data Exchange (ETDEWEB)

    Jacinto, Carlos M.C.; Barbosa, Valdir P. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Garcia, Pauli A.A. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Ramos, Fernando A.

    2008-07-01

    Some operations, due to unscientific knowledge, have been prohibited in E and P activities. Among these operations one have night pumping of flammable fluid and pressure test with maritime diesel. For this reason one has a considerable lost of time due to the necessity to wait until the morning of the day after, in case of night pumping, or due to logistic skills concerning the difficulties to obtain materials which can be adopted in place of the maritime diesel. In turn to verify, scientifically, funding on a probabilistic safety analysis, the present paper present a hybrid approach, due to the high complexity of the considered scenario. In this hybrid approach, one has: HAZOP, event trees, Bayesian network, fault trees, and Bayesian inference for expert opinions estimation. The obtained results are satisfactory haven in view that they show the probability of occurrence of a catastrophic event concerning the analyzed operations. The obtained results are very satisfactory due to the fact that the one have obtained the probability values of undesirable events, and these values can be compared to the reference one. These reference figures are known as ALARP and are proposed by HSE. (author)

  20. Evaluation of Burning Test Rate Method for Flammable Solids to Increase air-Cargo Safety.

    Science.gov (United States)

    Lukežič, Marjan; Marinšek, Marjan; Faganeli, Jadran

    2010-03-01

    This paper deals with a standard classification procedure for readily combustible solids and their assignment to the relevant packing groups according to international air-cargo legislation and regulations. The current International Air Transport Association and United Nations Orange Book regulations were used on chemically similar substances: hexamethylenetetramine and Dancook ignition briquettes, which are both assigned into the same Packing Group III. To critically evaluate the degree of hazard both chemicals present, a standard burning test rate as well as thermogravimetry, differential scanning calorimetry and evolved gas analysis measurements were performed. It was shown that relatively small changes in the chemical composition of the material may have essential influence on the package group determination. Taking into account all the facts collected in the experimental work, it was concluded that ignition briquettes will undergo spontaneous combustion if exposed to elevated temperatures and, from this point of view, represent higher risk than hexamethylenetetramine during air transportation. Therefore, ignition briquettes should be classified into Packing Group II.