WorldWideScience

Sample records for maternal-fetal monitoring system

  1. Maternal, Fetal and Neonatal Outcomes in Pregnant Women with Systemic Lupus Erythematosus: A Comprehensive Review Study

    Directory of Open Access Journals (Sweden)

    Fatemeh Zahra Karimi

    2017-11-01

    Full Text Available Background:Systemic lupus erythematosus (SLE is an autoimmune disease with multiple organ involvement and periods of relapse and remission that mainly affects young women of childbearing age. In this regard the reproductive health is an important issue. Although diagnosis, treatment and management of pregnancy in SLE women have been improved recently, but the main concern is effects of SLE on maternal, fetal and neonatal outcomes. This study aimed to investigate the maternal, fetal and neonatal outcomes in pregnant women with SLE. Materials and Methods: The databases of PubMed, Medline, Scopus and Web of Science as well as domestic database (Persian such as SID, Magiran, Irandoc, and Google Scholar were searched with using keywords such as" Systemic lupus erythematosus"; "Pregnancy"; "Neonatal lupus"; "maternal, fetus or neonatal outcome";  and equivalent Persian words. Included were all Persian and English articles, published between 2000 and May 2017. Finally, a total of 77 studies were included. Results: Adverse perinatal outcomes increase in pregnancies with lupus. Outcomes include respiratory, cardiovascular, blood and skin disorders in mothers; stillbirth, spontaneous, and recurrent abortion in fetuses and neonatal lupus, prematurity, intrauterine growth restriction (IUGR, and small for gestational age (SGA in neonates, respectively. Conclusion: Pregnant women with SLE are at high risk due to increased complications for both mother and fetus. It seems broad control of the women before fertilization, so that they be at full remission in the beginning of pregnancy and the disease activity be in complete control, it can help to improve outcomes of pregnancy and so better results can be expected.

  2. Society for Maternal-Fetal Medicine

    Science.gov (United States)

    ... checklists in obstetrics Coding update of the SMFM definition of low risk for cesarean delivery from ICD- ... DC 20024 Email: smfm@smfm.org © 2000-2017, Society for Maternal-Fetal Medicine. All rights reserved The ...

  3. Metabolomics Application in Maternal-Fetal Medicine

    OpenAIRE

    Fanos, Vassilios; Atzori, Luigi; Makarenko, Karina; Melis, Gian Benedetto; Ferrazzi, Enrico

    2013-01-01

    Metabolomics in maternal-fetal medicine is still an “embryonic” science. However, there is already an increasing interest in metabolome of normal and complicated pregnancies, and neonatal outcomes. Tissues used for metabolomics interrogations of pregnant women, fetuses and newborns are amniotic fluid, blood, plasma, cord blood, placenta, urine, and vaginal secretions. All published papers highlight the strong correlation between biomarkers found in these tissues and fetal malformations, prete...

  4. Metabolomics Application in Maternal-Fetal Medicine

    Directory of Open Access Journals (Sweden)

    Vassilios Fanos

    2013-01-01

    Full Text Available Metabolomics in maternal-fetal medicine is still an “embryonic” science. However, there is already an increasing interest in metabolome of normal and complicated pregnancies, and neonatal outcomes. Tissues used for metabolomics interrogations of pregnant women, fetuses and newborns are amniotic fluid, blood, plasma, cord blood, placenta, urine, and vaginal secretions. All published papers highlight the strong correlation between biomarkers found in these tissues and fetal malformations, preterm delivery, premature rupture of membranes, gestational diabetes mellitus, preeclampsia, neonatal asphyxia, and hypoxic-ischemic encephalopathy. The aim of this review is to summarize and comment on original data available in relevant published works in order to emphasize the clinical potential of metabolomics in obstetrics in the immediate future.

  5. Simulation in maternal-fetal medicine: making a case for the need.

    Science.gov (United States)

    Goffman, Dena; Colleen, Lee; Bernstein, Peter S

    2013-06-01

    Medical error remains a cause for concern in obstetrics. Studies have shown that the most important contributing factors to adverse events in obstetrics often relate to poor teamwork and ineffective communication. A potential solution to these problems includes transforming institutions, obstetric departments, and maternal-fetal medicine divisions into high-reliability organizations. Simulation is a valuable tool which can be utilized, in obstetrics and maternal-fetal medicine, as an integral part of programs designed to advance knowledge and technical skills; improve communication and team function; and identify and correct systems issues. Simulation should be an integral part of our journey towards high reliability with the ultimate goal of improving patient safety and quality of care in obstetrics. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. MATERNAL-FETAL TOLERANCE AS A MANIFESTATION OF REGULATORY CONTINUUM AND PLASTICITY OF THEIR IMMUNE SYSTEMS (in memory of I.P. Ashmarin

    Directory of Open Access Journals (Sweden)

    E. P. Kharchenko

    2011-01-01

    Full Text Available Abstract. Relations of immune tolerance between mother and fetus are considered in view of a common regulatory continuum which is formed under the influence of a growing fetus. To explain such an immune tolerance, a notion of immune system plasticity is introduced, as an analogue to the nervous system plasticity, which develops in response to a continuum of changes occurring in fetal and maternal organisms during the nine months of pregnancy. The immune system plasticity in females is supposed to be among possible factors causing collisions upon conception and in the course of pregnancy. (Med. Immunol., 2011, vol. 13, N 2-3, pp 121-132

  7. Magnesium 1993 Maternal-Fetal Toxicology. A Clinician's Guide ...

    African Journals Online (AJOL)

    I S I G I 0 I M I. Maternal-Fetal Toxicology. A Clinician's. Guide. 2nd edition. Ed. by Gideon Koren. Pp. 824 ... analysis is presented, and survival curve ideas for effects over time. Final chapters ... SPSS-PC+, SAS and Nanostat. Several important.

  8. What do we know about maternal-fetal attachment?

    Science.gov (United States)

    Shieh, C; Kravitz, M; Wang, H H

    2001-09-01

    A review of the literature suggests that there are three critical attributes related to the concept of maternal-fetal attachment, including cognitive, affective, and altruistic attachment. Cognitive attachment is the desire to know the baby. Affective attachment is the pleasure associated with thoughts of or interaction with the fetus. Altruistic attachment refers to a desire to protect the unborn child. Existing measurements on maternal-fetal attachment are developed based on low-risk and white pregnant women and previous research has not yet resulted in a consistent theoretical model. Future research should focus on development of culturally sensitive instruments and combining qualitative and quantitative measures to broaden theoretical understanding of the concept. Nursing assessment of maternal-fetal attachment is an on-going process. The nurse's role is to reassure those who have developed attachment to their fetuses and to motivate those who are unaware of or unconcerned about their attachment to their fetuses. Collecting data from different attributes of attachment helps nurses identify each woman's attachment patterns and areas of concern.

  9. A Review of the Importance of Maternal-fetal Attachment According to the Islamic Recommendations

    OpenAIRE

    Fatemeh Ghodrati; Marzieh Akbarzadeh

    2018-01-01

    Background & aim: Maternal-fetal attachment has an important effect on mother's identity as well as maternal and fetal health. Moreover, this concept is considered as a crucial issue for the improvement of children emotional development. Regarding the Islamic recommendations on maternal-fetal attachment and its correlation with maternal affection, this study was conducted to review the importance of maternal-fetal attachment according to the Islamic recommendations. Methods: This review was c...

  10. Variations in management of mild prenatal hydronephrosis among maternal-fetal medicine obstetricians, and pediatric urologists and radiologists.

    Science.gov (United States)

    Zanetta, Vitor C; Rosman, Brian M; Bromley, Bryan; Shipp, Thomas D; Chow, Jeanne S; Campbell, Jeffrey B; Herndon, C D Anthony; Passerotti, Carlo C; Cendron, Marc; Retik, Alan B; Nguyen, Hiep T

    2012-11-01

    There are no current guidelines for diagnosing and managing mild prenatal hydronephrosis. Variations in physician approach make it difficult to analyze outcomes and establish optimal management. We determined the variability of diagnostic approach and management regarding prenatal hydronephrosis among maternal-fetal medicine obstetricians, pediatric urologists and pediatric radiologists. Online surveys were sent to mailing lists for national societies for each specialty. Participants were surveyed regarding criteria for diagnosing mild prenatal hydronephrosis and recommendations for postnatal management, including use of antibiotic prophylaxis, followup scheduling and type of followup imaging. A total of 308 maternal-fetal medicine obstetricians, 126 pediatric urologists and 112 pediatric radiologists responded. Pediatric urologists and radiologists were divided between Society for Fetal Urology criteria and use of anteroposterior pelvic diameter for diagnosis, while maternal-fetal medicine obstetricians preferred using the latter. For postnatal evaluation radiologists preferred using personal criteria, while urologists preferred using anteroposterior pelvic diameter or Society for Fetal Urology grading system. There was wide variation in the use of antibiotic prophylaxis among pediatric urologists. Regarding the use of voiding cystourethrography/radionuclide cystography in patients with prenatal hydronephrosis, neither urologists nor radiologists were consistent in their recommendations. Finally, there was no agreement on length of followup for mild prenatal hydronephrosis. We observed a lack of uniformity regarding grading criteria in diagnosing hydronephrosis prenatally and postnatally among maternal-fetal medicine obstetricians, pediatric urologists and pediatric radiologists. There was also a lack of agreement on the management of mild intermittent prenatal hydronephrosis, resulting in these cases being managed inconsistently. A unified set of guidelines for

  11. 77 FR 42768 - Leadership Meeting on Maternal, Fetal, and Infant Opioid Exposure and Neonatal Abstinence Syndrome

    Science.gov (United States)

    2012-07-20

    ... OFFICE OF NATIONAL DRUG CONTROL POLICY Leadership Meeting on Maternal, Fetal, and Infant Opioid Exposure and Neonatal Abstinence Syndrome AGENCY: Office of National Drug Control Policy. ACTION: Notice. SUMMARY: An ONDCP Leadership Meeting on Maternal, Fetal and Infant Opioid Exposure and Neonatal Abstinence...

  12. Effect of Guided Imagery on Maternal Fetal Attachment in Nulliparous Women with Unplanned Pregnancy

    OpenAIRE

    Masoumeh Kordi; Maryam Fasanghari; Negar Asgharipour; Habibollah Esmaily

    2016-01-01

    Introduction and Objectives: Nulliparous women with unplanned pregnancy experience high levels of anxiety, which may adversely affect maternal-fetal attachment. Therefore, in this study, we aimed to determine the effect of guided imagery on maternal-fetal attachment in nulliparous women with unplanned pregnancy. Materials and Methods: In this clinical trial, 67 nulliparous women with unplanned pregnancy were randomly divided into two groups of intervention (n=35) and control (n=32) in 2015. D...

  13. The relation between social support, anxiety and distress symptoms and maternal fetal attachment.

    Science.gov (United States)

    Hopkins, Joyce; Miller, Jennifer L; Butler, Kristina; Gibson, Lynda; Hedrick, Laura; Boyle, Deborah Anne

    2018-05-04

    The aims of this study were to: (1) examine the relation between social support, trait anxiety, symptoms of maternal distress (including stress, depression and anxiety) and maternal-fetal attachment; and (2) to determine if social support buffers the relation between trait anxiety, symptoms of distress and maternal-fetal attachment. Ninety-four pregnant women completed five self-report questions. Two hierarchical regression analyses were conducted to examine the influence of trait anxiety, symptoms of distress, and social support on two factors of maternal-fetal attachment, quality and intensity/frequency. In the first model with the dependent measure as the maternal-fetal attachment quality score, trait anxiety (β = -.24, p social support (β = .30, p social support (β = .32, p social support is high, the relation between anxiety and maternal-fetal attachment intensity/frequency is attenuated. This study demonstrates that prenatal attachment is related to trait anxiety and social support. These findings suggest that interventions to decrease anxiety and increase social support could enhance maternal-fetal attachment.

  14. Impact of chronic maternal stress during early gestation on maternal-fetal stress transfer and fetal stress sensitivity in sheep.

    Science.gov (United States)

    Dreiling, Michelle; Schiffner, Rene; Bischoff, Sabine; Rupprecht, Sven; Kroegel, Nasim; Schubert, Harald; Witte, Otto W; Schwab, Matthias; Rakers, Florian

    2018-01-01

    Acute stress-induced reduction of uterine blood flow (UBF) is an indirect mechanism of maternal-fetal stress transfer during late gestation. Effects of chronic psychosocial maternal stress (CMS) during early gestation, as may be experienced by many working women, on this stress signaling mechanism are unclear. We hypothesized that CMS in sheep during early gestation augments later acute stress-induced decreases of UBF, and aggravates the fetal hormonal, cardiovascular, and metabolic stress responses during later development. Six pregnant ewes underwent repeated isolation stress (CMS) between 30 and 100 days of gestation (dGA, term: 150 dGA) and seven pregnant ewes served as controls. At 110 dGA, ewes were chronically instrumented and underwent acute isolation stress. The acute stress decreased UBF by 19% in both the CMS and control groups (p stress-induced cortisol and norepinephrine concentrations indicating a hyperactive hypothalamus-pituitary-adrenal (HPA)-axis and sympathetic-adrenal-medullary system. Increased fetal norepinephrine is endogenous as maternal catecholamines do not cross the placenta. Cortisol in the control but not in the CMS fetuses was correlated with maternal cortisol blood concentrations; these findings indicate: (1) no increased maternal-fetal cortisol transfer with CMS, (2) cortisol production in CMS fetuses when the HPA-axis is normally inactive, due to early maturation of the fetal HPA-axis. CMS fetuses were better oxygenated, without shift towards acidosis compared to the controls, potentially reflecting adaptation to repeated stress. Hence, CMS enhances maternal-fetal stress transfer by prolonged reduction in UBF and increased fetal HPA responsiveness.

  15. [Design and Application of High-risk Pregnancy Monitoring & Warning Internet Platform Based on Internet of Things].

    Science.gov (United States)

    Lu, Heqing; Zhang, Xiaofeng; Li, Bin

    2017-09-30

    Through illustrating the designing of high-risk pregnancy maternal-fetal monitoring system based on the internet of things, this paper introduced the specific application of using wearable medical devices to provide maternal-fetal mobile medical services. With the help of big data and cloud obstetrics platform, the monitoring and warning network was further improved, the level-to-level administration of high-risk pregnancy was realized, the level of perinatal health care was enhanced and the risk of critical emergency of pregnancy decreased.

  16. Effect of Guided Imagery on Maternal Fetal Attachment in Nulliparous Women with Unplanned Pregnancy

    Directory of Open Access Journals (Sweden)

    Masoumeh Kordi

    2016-10-01

    Full Text Available Introduction and Objectives: Nulliparous women with unplanned pregnancy experience high levels of anxiety, which may adversely affect maternal-fetal attachment. Therefore, in this study, we aimed to determine the effect of guided imagery on maternal-fetal attachment in nulliparous women with unplanned pregnancy. Materials and Methods: In this clinical trial, 67 nulliparous women with unplanned pregnancy were randomly divided into two groups of intervention (n=35 and control (n=32 in 2015. Data collection tools included a demographic form and London, DASS 21, and Cranley's maternal-fetal attachment questionnaires. In the intervention group, one session of guided imagery on maternal role was performed in 34th week of pregnancy in groups of four to seven. Afterwards, guided imagery CDs were given to mothers to be performed at home twice a week for two weeks; the control group only received the routine care. Maternal-fetal attachment was assessed before and two weeks after the intervention. To analyze the data, independent t-test, paired t-test, Chi-squared, Fisher’s exact test, and Mann-Whitney U tests were run using SPSS version 21. Results: Maternal mean age was 24.1±4.3 years, and most mothers (49.3% had high school education. Mean score of maternal-fetal attachment was significantly different between the intervention (94.26±6.7 and control (90.22 ± 9.5 groups after the intervention (P=0.04. Also, there was a significant difference between mean score of maternal-fetal attachment at the beginning and end of the intervention in the intervention and control groups (5.86±7.2 vs. 1.72±3.2; P=0.004. Conclusion: Guided imagery promoted maternal-fetal attachment in women with unplanned pregnancy; thus, it is recommended to use this method in prenatal care for these women.

  17. Maternal-fetal cholesterol transport in the second half of mouse pregnancy does not involve LDL receptor-related protein 2.

    Science.gov (United States)

    Zwier, M V; Baardman, M E; van Dijk, T H; Jurdzinski, A; Wisse, L J; Bloks, V W; Berger, R M F; DeRuiter, M C; Groen, A K; Plösch, T

    2017-08-01

    LDL receptor-related protein type 2 (LRP2) is highly expressed on both yolk sac and placenta. Mutations in the corresponding gene are associated with severe birth defects in humans, known as Donnai-Barrow syndrome. We here characterized the contribution of LRP2 and maternal plasma cholesterol availability to maternal-fetal cholesterol transport and fetal cholesterol levels in utero in mice. Lrp2 +/- mice were mated heterozygously to yield fetuses of all three genotypes. Half of the dams received a 0.5% probucol-enriched diet during gestation to decrease maternal HDL cholesterol. At E13.5, the dams received an injection of D7-labelled cholesterol and were provided with 1- 13 C acetate-supplemented drinking water. At E16.5, fetal tissues were collected and maternal cholesterol transport and fetal synthesis quantified by isotope enrichments in fetal tissues by GC-MS. The Lrp2 genotype did not influence maternal-fetal cholesterol transport and fetal cholesterol. However, lowering of maternal plasma cholesterol levels by probucol significantly reduced maternal-fetal cholesterol transport. In the fetal liver, this was associated with increased cholesterol synthesis rates. No indications were found for an interaction between the Lrp2 genotype and maternal probucol treatment. Maternal-fetal cholesterol transport and endogenous fetal cholesterol synthesis depend on maternal cholesterol concentrations but do not involve LRP2 in the second half of murine pregnancy. Our results suggest that the mouse fetus can compensate for decreased maternal cholesterol levels. It remains a relevant question how the delicate system of cholesterol transport and synthesis is regulated in the human fetus and placenta. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  18. A Review of the Importance of Maternal-fetal Attachment According to the Islamic Recommendations

    Directory of Open Access Journals (Sweden)

    Fatemeh Ghodrati

    2018-01-01

    Full Text Available Background & aim: Maternal-fetal attachment has an important effect on mother's identity as well as maternal and fetal health. Moreover, this concept is considered as a crucial issue for the improvement of children emotional development. Regarding the Islamic recommendations on maternal-fetal attachment and its correlation with maternal affection, this study was conducted to review the importance of maternal-fetal attachment according to the Islamic recommendations. Methods: This review was conducted on the religious texts, which covered the subject of interest and were published within 2000-2017. Various databases including Medline, PubMed, Google, IranMedex, SID, and Magiran as well as the websites of Muslim authorities (i.e., the section responding to religious questions were searched. The searching was carried out using keywords as: “Islamic religious teachings”, “pregnant women and Fatwa of the Islamic jurists”, and “aspects of maternal fetal attachment in Islam”. Results: According to the results of the reviewed texts, the mutual readiness of mother and fetus leads to the improvement of their affection. The maternal factors affecting the maternal-neonatal attachment included personality traits, marriage, selection of partner, post-marriage issues, pregnancy, as well as physical and psychological characteristics. There were also some effective factors on the newborn’s innate readiness for the development of attachment, such as fetal appearance, family and social support, maternal nutrition during pregnancy, and neonatal mood. Conclusion: According to the Holy Quran versus and hadiths, maternal-fetal attachment and its promotion are affected by both maternal and fetal factors. Moreover, following the factors affecting attachment will lead to their role functioning. Therefore, it is intensively recommended to incorporate a glance of Islamic instruction into the pregnancy education to improve the maternal-fetal attachment.

  19. Evaluation of the maternal-fetal transfer of granisetron in an ex vivo placenta perfusion model.

    Science.gov (United States)

    Julius, Justin M; Tindall, Andrew; Moise, Kenneth J; Refuerzo, Jerrie S; Berens, Pamela D; Smith, Judith A

    2014-11-01

    The objective of this study was to estimate maternal-fetal transplacental passage of granisetron in an ex vivo placental perfusion model. Term human placentas (N=8) were collected immediately after delivery. A single cotyledon from each placenta was perfused granisetron concentration to mimic systemic maternal peak plasma concentrations following either IV (50ng/mL) or transdermal administration (5ng/mL). To assess drug transfer and accumulation, samples were collected from maternal and fetal compartments. In the 50ng/mL open model, the mean transport fraction was 0.21±0.08 with clearance index of 0.53±0.66. Fetal peak concentrations achieved was 5.6±6.6ng/mL with mean accumulation of 5.35±6.4ng/mL. No drug was detected in the fetal compartment with the 5ng/mL models. Transplacental passage of granisetron was inconsistent at the 50ng/mL concentration that achieved with IV dosing. However, there consistently was no detectable passage in all the placentas evaluated of the granisetron at 5ng/mL concentration that would be achieved after transdermal patch administration. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Analysis of maternal-fetal outcomes of valvular heart surgeries in

    Directory of Open Access Journals (Sweden)

    Alireza Yaghoubi

    2010-03-01

    Full Text Available Valvular heart surgery (VHS in pregnancy has its specific complexity and problems.Between years 1983-2007 11 women who underwent VHS during pregnancy were found and analyzed. Valvular heart surgery in pregnancy is associated with the least maternal-fetal side effects. Intensive evaluations before and during pregnancy with a specialized medical team is essential

  1. Improved performance of maternal-fetal medicine staff after maternal cardiac arrest simulation-based training.

    Science.gov (United States)

    Fisher, Nelli; Eisen, Lewis A; Bayya, Jyothshna V; Dulu, Alina; Bernstein, Peter S; Merkatz, Irwin R; Goffman, Dena

    2011-09-01

    To determine the impact of simulation-based maternal cardiac arrest training on performance, knowledge, and confidence among Maternal-Fetal Medicine staff. Maternal-Fetal Medicine staff (n = 19) participated in a maternal arrest simulation program. Based on evaluation of performance during initial simulations, an intervention was designed including: basic life support course, advanced cardiac life support pregnancy modification lecture, and simulation practice. Postintervention evaluative simulations were performed. All simulations included a knowledge test, confidence survey, and debriefing. A checklist with 9 pregnancy modification (maternal) and 16 critical care (25 total) tasks was used for scoring. Postintervention scores reflected statistically significant improvement. Maternal-Fetal Medicine staff demonstrated statistically significant improvement in timely initiation of cardiopulmonary resuscitation (120 vs 32 seconds, P = .042) and cesarean delivery (240 vs 159 seconds, P = .017). Prompt cardiopulmonary resuscitation initiation and pregnancy modifications application are critical in maternal and fetal survival during cardiac arrest. Simulation is a useful tool for Maternal-Fetal Medicine staff to improve skills, knowledge, and confidence in the management of this catastrophic event. Published by Mosby, Inc.

  2. Rab11 family expression in the human placenta: Localization at the maternal-fetal interface

    Science.gov (United States)

    Artemiuk, Patrycja A.; Hanscom, Sara R.; Lindsay, Andrew J.; Wuebbolt, Danielle; Breathnach, Fionnuala M.; Tully, Elizabeth C.; Khan, Amir R.; McCaffrey, Mary W.

    2017-01-01

    placenta, with novel localization at the maternal-fetal interface. PMID:28922401

  3. The influence of physical activity during pregnancy on maternal, fetal or infant heart rate variability: a systematic review.

    Science.gov (United States)

    Dietz, Pavel; Watson, Estelle D; Sattler, Matteo C; Ruf, Wolfgang; Titze, Sylvia; van Poppel, Mireille

    2016-10-26

    Physical activity (PA) during pregnancy has been shown to be associated with several positive effects for mother, fetus, and offspring. Heart rate variability (HRV) is a noninvasive and surrogate marker to determine fetal overall health and the development of fetal autonomic nervous system. In addition, it has been shown to be significantly influenced by maternal behavior. However, the influence of maternal PA on HRV has not yet been systematically reviewed. Therefore, the aim of this systematic review was to assess the influence of regular maternal PA on maternal, fetal or infant HRV. A systematic literature search following a priori formulated criteria of studies that examined the influence of regular maternal PA (assessed for a minimum period of 6 weeks) on maternal, fetal or infant HRV was performed in the databases Pubmed and SPORTDiscus. Quality of each study was assessed using the standardized Quality Assessment Tool for Quantitative Studies (QATQS). Nine articles were included into the present systematic review: two intervention studies, one prospective longitudinal study, and six post-hoc analysis of subsets of the longitudinal study. Of these articles four referred to maternal HRV, five to fetal HRV, and one to infant HRV. The overall global rating for the standardized quality assessment of the articles was moderate to weak. The articles regarding the influence of maternal PA on maternal HRV indicated contrary results. Five of five articles regarding the influence of maternal PA on fetal HRV showed increases of fetal HRV on most parameters depending on maternal PA. The article referring to infant HRV (measured one month postnatal) showed an increased HRV. Based on the current evidence available, our overall conclusion is that the hypothesis that maternal PA influences maternal HRV cannot be supported, but there is a trend that maternal PA might increase fetal and infant HRV (clinical conclusion). Therefore, we recommend that further, high quality studies

  4. Prediction of Maternal-Fetal Attachment Based on the Components of Gender Role in Pregnant women

    Directory of Open Access Journals (Sweden)

    Mojgan Zolfaghari

    2016-10-01

    Full Text Available Background and aim: Maternal concept is part of the feminine gender role. The important part of the maternal concept is the unique relationship experience between mother and child that begins with  maternal-fetal attachment(MFA during pregnancy. The aim of this study is predict the MFA according to Gender role in pregnant women in Shiraz city. Methods:This descriptive correlational study was conducted on 171 primiparous and multiparous women with Gestational age above 24 weeks of pregnancy reffering to the obstetric and midwifery department of Shiraz –Kowsar Hospital during 2 monthes period from May to June 2015,  which were selected using the Purposive sampling.Data were collected using a Demographic obstetric questionnaire   including  age and obstetric information,Cranly’s Maretnal Fetal Attachment  questionnaire(validity:0.85 and Bem Gender Role questionnaire(reliability:0.90 were used during this study.  For data analysis  Pearson correlation coefficient and multiple regression were performed,using spss version 16. Results:  Results showed a statistically significant correlation between components of femininity and masculinity of gender role with maternal-fetal attachment. Maximum correlation was between Masculinity and MFA ( R=0.33, P=0.001 and then between Femininity and MFA  (R=0.24,P=0.009.There was no correlation between neutral and MFA.(R=0.12,P=0.084  Almost 14% of the variance in maternal-fetal attachment was explained by gender role . According to the comparison of regression coefficients, the femininity indicator (β=0.159 ,P=0.015 and masculinity indicator (β=0.266, P=0.001 were positively predicted the maternal-fetal attachment, but neutral component (β=0.109, P=0.064 was not predicted the maternal-fetal attachment (Table 2. Conclusions: Gender role is part of mental health that predicts MFA during pregnancy. Mental health of mother and fetus can be improved by identifying mothers based Gender role. These

  5. Placental adaptations to the maternal-fetal environment: implications for fetal growth and developmental programming.

    Science.gov (United States)

    Sandovici, Ionel; Hoelle, Katharina; Angiolini, Emily; Constância, Miguel

    2012-07-01

    The placenta is a transient organ found in eutherian mammals that evolved primarily to provide nutrients for the developing fetus. The placenta exchanges a wide array of nutrients, endocrine signals, cytokines and growth factors with the mother and the fetus, thereby regulating intrauterine development. Recent studies show that the placenta is not just a passive organ mediating maternal-fetal exchange. It can adapt its capacity to supply nutrients in response to intrinsic and extrinsic variations in the maternal-fetal environment. These dynamic adaptations are thought to occur to maximize fetal growth and viability at birth in the prevailing conditions in utero. However, some of these adaptations may also affect the development of individual fetal tissues, with patho-physiological consequences long after birth. Here, this review summarizes current knowledge on the causes, possible mechanisms and consequences of placental adaptive responses, with a focus on the regulation of transporter-mediated processes for nutrients. This review also highlights the emerging roles that imprinted genes and epigenetic mechanisms of gene regulation may play in placental adaptations to the maternal-fetal environment. Copyright © 2012 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Distortion of maternal-fetal angiotensin II type 1 receptor allele transmission in pre-eclampsia.

    Science.gov (United States)

    Morgan, L; Crawshaw, S; Baker, P N; Brookfield, J F; Broughton Pipkin, F; Kalsheker, N

    1998-01-01

    OBJECTIVE: To investigate the fetal angiotensin II type 1 receptor genotype in pre-eclampsia. DESIGN: Case-control study. POPULATION: Forty-one maternal-fetal pairs from pre-eclamptic pregnancies and 80 maternal-fetal pairs from normotensive pregnancies. METHODS: Maternal and fetal DNA was genotyped at three diallelic polymorphisms, at nucleotides 573, 1062, and 1166, in the coding exon of the angiotensin II type 1 receptor gene, and at a dinucleotide repeat polymorphism in its 3' flanking region. RESULTS: Allele and genotype frequencies at the four polymorphic regions investigated did not differ between pre-eclamptic and normotensive groups, in either fetal or maternal samples. Mothers heterozygous for the dinucleotide repeat allele designated A4 transmitted this allele to the fetus in 15 of 18 informative pre-eclamptic pregnancies and in eight of 26 normotensive pregnancies. This was greater than the expected probability in pre-eclamptic pregnancies (p=0.04) and less than expected in normotensive pregnancies (p<0.005). The 573T variant, which is in partial linkage disequilibrium with the A4 allele, showed a similar distortion of maternal-fetal transmission. CONCLUSION: Angiotensin II type 1 receptor gene expression in the fetus may contribute to the aetiology of pre-eclampsia. It is unclear whether susceptibility is conferred by the fetal genotype acting alone, or by allele sharing by mother and fetus. Possible mechanisms for the effect of the angiotensin II type 1 receptor gene are suggested by the association of the 573T variant with low levels of surface receptor expression on platelets. If receptor expression is similarly genetically determined in the placenta, responsiveness to angiotensin II may be affected, with the potential to influence placentation or placental prostaglandin secretion. PMID:9719367

  7. Onset of human preterm and term birth is related to unique inflammatory transcriptome profiles at the maternal fetal interface

    Directory of Open Access Journals (Sweden)

    Radek Bukowski

    2017-09-01

    suppression of chemokines expression in TNL, withdrawal of this suppression in TL, activation of multiple pathways of inflammation in PL, and an immune rejection profile in PNL. The genes constituting expression signatures showed over-representation of three putative regulatory elements in their 5′and 3′ UTR regions. Conclusions The results suggest that pregnancy is maintained by downregulation of chemokines at the maternal-fetal interface. Withdrawal of this downregulation results in the term birth and its overriding by the activation of multiple pathways of the immune system in the preterm birth. Complications of the pregnancy associated with impairment of placental function, which necessitated premature delivery of the fetus in the absence of labor, show gene expression patterns associated with immune rejection.

  8. Lipoprotein Profile Modifications during Gestation: A Current Approach to Cardiovascular risk surrogate markers and Maternal-fetal Unit Complications.

    Science.gov (United States)

    Santos, Ana Paula Caires Dos; Couto, Ricardo David

    2018-05-16

    Several changes occur in lipid metabolism during gestation due to hormonal and metabolic changes, which are essential to satisfy the nutritional demands of the maternal-fetal unit development. The gestation shows two distinct periods that begin with fat accumulation, mainly in maternal adipose tissue, and the late phase, characterized by accelerated catabolism, with the increase of fatty acids in the circulation that causes hyperlipidemia, especially the one characterized as hypertriglyceridemia. Maternal hyperlipidemia may be associated with the development of maternal-fetal complications (preterm birth, preeclampsia, vascular complications) and the development of long-term cardiovascular disease. The cardiovascular risk may not only be related to lipoproteins cholesterol content, but also to the number and functionality of circulating lipoprotein particles. This review reports the major changes that occur in lipoprotein metabolism during pregnancy and that are associated with the development of dyslipidemias, lipoprotein atherogenic phenotype, and maternal-fetal unit complications. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  9. Maternal-fetal disease information as a source of exercise motivation during pregnancy.

    Science.gov (United States)

    Gaston, Anca; Prapavessis, Harry

    2009-11-01

    A Protection Motivation Theory (PMT) framework was used to examine whether information about the role of exercise in preventing maternal-fetal disease served as a meaningful source of exercise motivation. Pregnant women (n = 208) were randomly assigned into one of three conditions: PMT, attention control, and noncontact control. Women in the PMT group read a brochure about the benefits of exercise during pregnancy incorporating the major components of PMT; perceived vulnerability (PV), perceived severity (PS), response efficacy (RE), and self-efficacy (SE). Participants in the attention-control condition read a brochure about diet. Following treatment, all participants completed measures of their beliefs toward maternal-fetal disease and exercise, goal intention (GI), and implementation intention (IMI). One week later, a measure of self-reported exercise behavior was collected. Main outcome measures were PMT variables (PV, PS, RE, and SE), GI, IMI, and follow-up physical activity. Participants assigned to the PMT-present group reported significantly higher PS, RE, SE, GI, and increased exercise behavior. PS, RE, and SE predicted GI, GI predicted IMI, and IMI predicted exercise behavior. Information grounded in PMT is effective in influencing pregnant women's beliefs and intentions as well as changing their initial behavior. PsycINFO Database Record (c) 2009 APA, all rights reserved.

  10. Maternal-Fetal Medicine Physician and Fellow Perceptions of Business in Medicine.

    Science.gov (United States)

    Porter, Blake; Iriye, Brian; Ghamsary, Mark

    2018-01-01

     Principles of practice management provide a foundation for clinical success and performance improvement. Scant data exist regarding maternal-fetal medicine (MFM) physicians' knowledge of these topics. We hypothesize that physicians enter practice with inadequate education in practice management.  Surveys were emailed to members of the Society for Maternal-Fetal Medicine rating their knowledge and capabilities in practice management topics, and respondents assessed their current institution's business in the medical curriculum.  A total of 325 (14.4%) physicians responded: 63 fellows in training and 262 MFM physician subspecialists. Practicing physicians reported learning most of their knowledge "in practice after fellowship" (85%) or "never at all" (10%). Only 3% of respondents had adequate business education during fellowship, and only 5% felt prepared to teach business principles. However, 85% of those surveyed agreed that this material should be taught during the fellowship. Among MFM subspecialists and fellows in training at institutions with fellowships, 60% reported no current curriculum for practice management, and those with current curricula reported it had "limited" or "no value" (76%).  There is a significant desire for practice management curricula during MFM fellowship, and current training is insufficient. With many MFM physicians ill-prepared to teach these principles, professional education from other financial fields, and standardized education in practice management from current expert sources is needed. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Maternal-fetal transmission of Trypanosoma cruzi, a health problem slightly studied in Mexico: case Chiapas

    Directory of Open Access Journals (Sweden)

    Guillermina Campos-Valdez

    2016-05-01

    Full Text Available Objective. To determine the Trypanosoma cruzi infection prevalence in 1125 pregnant women and the transmission frequency to their children from Tapachula and Palenque, Chiapas. Materials and methods. We determined the prevalence by serology tests and the transmission frequency by polymerase chain reaction (PCR and T. cruzi reactivity capacity after 12 months. Results. Total maternal infection prevalence were 23/1 125 (2.04%, 9/600 (1.5% were from Tapachula and 14/525 (2.6% from Palenque. The seropositive women were between 20 and 35 years old, 31.8% have Premature Rapture of Membrane and 9.1% have history of perinatal death. The total percentage of positive newborns by PCR was 9/23 (39.13%, out of those 2/9 (22.2% are from Tapachula and 7/14 (50% from Palenque. The Maternal Fetal transmission frequency was. 2/9 (22.2% in Tapachula and 1/14 (7.14% in Palenque, all positive infants were asynthomatic. Conclusion. The maternal-fetal transmission rate in Chiapas State is variable; the reason could be the maternal immunological status and T. cruzi strain.

  12. Effect of ethanol consumption during gestation on maternal-fetal amino acid metabolism in the rat

    International Nuclear Information System (INIS)

    Lin, G.W.

    1981-01-01

    The distribution of 14 C-alpha-aminoisobutyric acid (AIB), administered intravenously, in maternal, fetal and placental tissues was examined in the rat on gestation-day 21. Ethanol consumption during gestation (day 6 through 21) significantly reduced the uptake of AIB by the placenta and fetus while exerting no influence on maternal tissue AIB uptake. The concentration of fetal plasma free histidine was decreased 50% as a result of maternal ethanol ingestion, but the free histidine level of maternal plasma was not altered. Since no effect on protein content of fetal tissue could be detected, it is speculated that reduced histidine to the fetus might significantly alter the amounts of histamine and carnosine formed via their precursor. The significance of these findings in relation to the Fetal Alcohol Syndrome is discussed

  13. Female Physicians in Maternal-Fetal Medicine: A 32-Year Perspective.

    Science.gov (United States)

    Blackstone, Jacquelyn; Will, Vanessa K; Rayburn, William F

    2018-05-07

     To examine trends of female physicians either pursuing fellowships or in active practice in maternal-fetal medicine (MFM).  This observational study examined complete sets of MFM fellows and active members of the Society for Maternal-Fetal Medicine (SMFM) between 1985 and 2016. Databases from SMFM, American College of Obstetricians and Gynecologists (ACOG), and Accreditation Council for Graduate Medical Education were used. Analysis of covariance testing was used to assess interactions over time between groups.  The proportion of female MFM fellows increased steadily from 17.1% in 1985 to 72.5% in 2016. The proportion of females grew more rapidly among the MFM fellows than obstetrics and gynecology (ob-gyn) residents (2.1 vs. 1.4% per year; p  = 0.001) and among those who were active SMFM members than ACOG Fellows (1.4 vs. 1.2% per year; p  = 0.013). Slightly more than half (52.4%) of all SMFM members are now female and will approach two-thirds (64.4%) by 2025 (compared with 53.4% in 2016 and 65.3% in 2025 of ACOG fellows).  The rising proportion of female MFM fellows is directly related to the high number of female ob-gyn residents. Females comprise slightly more than half of all active SMFM members now and projected to approach two-thirds by 2025. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. [Effects of shoutai pills on expression of Th1/Th2 cytokine in maternal-fetal interface and pregnancy outcome].

    Science.gov (United States)

    Lai, Maohua; You, Zhaoling; Ma, Hongxia; Lei, Lei; Lu, Fangguo; He, Dongmei; Liu, Huiping; Yin, Sheng

    2010-11-01

    To evaluate its mechanism of inducing the maternal-fetal immune tolerance by studying the effects of Shoutai pills on the expression of Th1/Th2 cytokine and pregnancy in maternal-fetal interface of mice with recurrent spontaneous abortion (RSA). The normal pregnancy and RSA model were respectively induced with CBA/J x BALB/c and CBA/J x DBA/2. The mice with RSA were randomly divided into model group and low, middle and high dose groups of Shoutai pills. The mice were killed in 14 days after administration and embryo resorption rate was counted and their decidual and placental tissues were co-cultured to detect the expressions of IL-4, IL-10, IFN-gamma and TNF-alpha with ELISA. The embryo resorption rate of the model group was significantly higher than the normal pregnancy, middle and high dose groups of Shoutai pills could decreased the embryo resorption rate of the mice with RSA (P pills could decreased the expression of IFN-gamma and TNF-alpha (P pills. Middle and high doses of Shoutai pills could increased the expression of IL-4 and IL-10 (P pills. The mechanism about Shoutai pills can change Th1 /Th2 cytokine towards Th2 bias, which induced the maternal-fetal immune tolerance.

  15. Maternal-fetal communication of circadian phase in a precocious rodent, the spiny mouse

    International Nuclear Information System (INIS)

    Weaver, D.R.; Reppert, S.M.

    1987-01-01

    The development of circadian rhythms was examined in a precocious rodent species, the spiny mouse. Spiny mouse pups born and reared in constant darkness expressed robust circadian rhythms in locomotor activity as early as day 5 of live. Free-running activity rhythms of pups born and reared in constant darkness were coordinated with the dam on the day of birth. Postnatal maternal influences on pup rhythmicity are minimal in this species, as pups fostered on the day of birth to dams whose circadian phases were opposite to the pups' original dams were coordinated with their original dams on the day of birth. Studies using 2-deoxy-D-[1- 14 C]-glucose authoradiography showed that there were synchronous (coordinated) rhythms in metabolic activity in the maternal and fetal suprachiasmatic nuclei, directly demonstrating prenatal coordination of maternal and fetal rhythmicity. Maternal-fetal coordination of circadian phase was not the result of direct entrainment of the fetuses to the environmental light-dark cycle. These results demonstrate that there is prenatal communication of circadian phase in this precocious species, without demonstrable postnatal maternal influences on pup circadian rhythmicity. Spiny mice therefore represent an important animal model in which circadian rhythms in the postnatal period can be used to precisely assess prenatal influences on circadian phase

  16. Role of catecholamines in maternal-fetal stress transfer in sheep.

    Science.gov (United States)

    Rakers, Florian; Bischoff, Sabine; Schiffner, Rene; Haase, Michelle; Rupprecht, Sven; Kiehntopf, Michael; Kühn-Velten, W Nikolaus; Schubert, Harald; Witte, Otto W; Nijland, Mark J; Nathanielsz, Peter W; Schwab, Matthias

    2015-11-01

    We sought to evaluate whether in addition to cortisol, catecholamines also transfer psychosocial stress indirectly to the fetus by decreasing uterine blood flow (UBF) and increasing fetal anaerobic metabolism and stress hormones. Seven pregnant sheep chronically instrumented with uterine ultrasound flow probes and catheters at 0.77 gestation underwent 2 hours of psychosocial stress by isolation. We used adrenergic blockade with labetalol to examine whether decreased UBF is catecholamine mediated and to determine to what extent stress transfer from mother to fetus is catecholamine dependent. Stress induced transient increases in maternal cortisol and norepinephrine (NE). Maximum fetal plasma cortisol concentrations were 8.1 ± 2.1% of those in the mother suggesting its maternal origin. In parallel to the maternal NE increase, UBF decreased by maximum 22% for 30 minutes (P Fetal NE remained elevated for >2 hours accompanied by a prolonged blood pressure increase (P fetal NE and blood pressure increase and the shift toward anaerobic metabolism. We conclude that catecholamine-induced decrease of UBF is a mechanism of maternal-fetal stress transfer. It may explain the influence of maternal stress on fetal development and on programming of adverse health outcomes in later life especially during early pregnancy when fetal glucocorticoid receptor expression is limited. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. A study on maternal-fetal attachment in pregnant women undergoing fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Concetta Polizzi

    2017-03-01

    Full Text Available Purpose: To investigate the possible effects of the fetal echocardiography experience on the prenatal attachment process. The predictive effect of specific women’s psychological variables will be explored as well.Design and methods: This between groups study involved 85 women with pregnancy at risk who underwent the fetal echocardiography, and 83 women who were about to undergo the morphological scan. The tools employed were: the Prenatal Attachment Inventory (P.A.I. to explore the maternal-fetal attachment; the Maternity Social Support Scale to investigate the woman perception of being socially supported during pregnancy; both the Big Five Questionnaire and the FACES III to explore the personality traits of pregnant women and their perception of their couple relationship functioning.Findings: The outcomes of ANOVA do not show statistically significant differences between the two groups of the mothers-to-be with regard to the scores of the P.A.I. (F = .017; p = .897; η2 = .000, while the regression analysis of the possible effect of the maternal psychological variables on the mother-fetus relationship shows a statistically significant result only with regard to the “social support” variable (r2 = .061; df = 80; p = .025.Conclusions: It would seem that the process of the prenatal attachment develops independently whether the woman has to undergo a first level screening or a second level examination such as the fetal echocardiography.

  18. Maternal-Fetal Cancer Risk Assessment of Ochratoxin A during Pregnancy

    Directory of Open Access Journals (Sweden)

    Chit Shing Jackson Woo

    2016-03-01

    Full Text Available Increasing evidence has demonstrated that in utero exposure to environmental chemicals may interfere with fetal development and increase the risk of disease and cancer development later in life. Ochratoxin A (OTA has been proven to induce diverse toxic effects including teratogenicity, carcinogenicity, immunotoxicity and potential endocrine disruption. Due to the continuous and widespread occurrence of OTA as a potential contaminant of staple foods, there is increasing concern of in utero exposure of fetus to this mycotoxin. In this study, maternal-fetal risk assessment of OTA during pregnancy was conducted using the benchmark dose approach for genotoxic carcinogens. The daily intake of OTA for Egyptian pregnant women was estimated based on their serum OTA level using the refined Klaassen equation for pregnancy. Fetal exposure level was also estimated based on the maternal data. Comparison between the estimated daily exposure and the negligible cancer risk intake (NCRI, and the calculation of margin of exposure (MOE implicated that OTA exposure from dietary intake would be of low health concern for this general subpopulation of Egyptian women. This subpopulation of pregnant women was generally estimated not to be in high-risk for toxicity induced by OTA.

  19. Human Chorionic Gonadotropin Has Anti-Inflammatory Effects at the Maternal-Fetal Interface and Prevents Endotoxin-Induced Preterm Birth, but Causes Dystocia and Fetal Compromise in Mice1

    Science.gov (United States)

    Furcron, Amy-Eunice; Romero, Roberto; Mial, Tara N.; Balancio, Amapola; Panaitescu, Bogdan; Hassan, Sonia S.; Sahi, Aashna; Nord, Claire; Gomez-Lopez, Nardhy

    2016-01-01

    Human chorionic gonadotropin (hCG) is implicated in the maintenance of uterine quiescence by down-regulating myometrial gap junctions during pregnancy, and it was considered as a strategy to prevent preterm birth after the occurrence of preterm labor. However, the effect of hCG on innate and adaptive immune cells implicated in parturition is poorly understood. Herein, we investigated the immune effects of hCG at the maternal-fetal interface during late gestation, and whether this hormone can safely prevent endotoxin-induced preterm birth. Using immunophenotyping, we demonstrated that hCG has immune effects at the maternal-fetal interface (decidual tissues) by: 1) increasing the proportion of regulatory T cells; 2) reducing the proportion of macrophages and neutrophils; 3) inducing an M1 → M2 macrophage polarization; and 4) increasing the proportion of T helper 17 cells. Next, ELISAs were used to determine whether the local immune changes were associated with systemic concentrations of progesterone, estradiol, and/or cytokines (IFNgamma, IL1beta, IL2, IL4, IL5, IL6, IL10, IL12p70, KC/GRO, and TNFalpha). Plasma concentrations of IL1beta, but not progesterone, estradiol, or any other cytokine, were increased following hCG administration. Pretreatment with hCG prevented endotoxin-induced preterm birth by 44%, proving the effectiveness of this hormone as an anti-inflammatory agent. However, hCG administration alone caused dystocia and fetal compromise, as proven by Doppler ultrasound. These results provide insight into the mechanisms whereby hCG induces an anti-inflammatory microenvironment at the maternal-fetal interface during late gestation, and demonstrate its effectiveness in preventing preterm labor/birth. However, the deleterious effects of this hormone on mothers and fetuses warrant caution. PMID:27146032

  20. Monitorização materno-fetal durante procedimento odontológico em portadora de cardiopatia valvar Monitoreo maternofetal durante procedimiento odontológico en portadora de cardiopatía valvular Maternal-fetal monitoring during dental procedure in patients with heart valve disease

    Directory of Open Access Journals (Sweden)

    Itamara Lucia Itagiba Neves

    2009-11-01

    , electrocardiografía ambulatoria materna y cardiotocografía de 31 portadoras de cardiopatía reumática, entre la 28ª y la 37ª semana de gestación, divididas en dos grupos según la presencia o no del vasoconstrictor. RESULTADOS: Se observó reducción significativa de los valores de frecuencia cardíaca materna en los dos grupos, durante el procedimiento, al compararlo con los demás períodos (p 0,05. Lo mismo ocurrió (p > 0,05 con el número de contracciones uterinas, nivel de variabilidad de la línea de base y número de aceleraciones de la frecuencia cardíaca fetal. CONCLUSIÓN: El uso de 1,8 ml de lidocaína 2% asociado a la adrenalina se mostró seguro y eficaz en procedimiento odontológico restaurador durante la gestación de mujeres con cardiopatía valvular reumática.BACKGROUND: The effects of local dental anesthesia with lidocaine and epinephrine on cardiovascular parameters of pregnant women with heart valve diseases and their fetuses are not fully understood. OBJECTIVES: To assess and analyze cardiotocographic, blood pressure and electrocardiographic parameters of pregnant women with rheumatic heart valve disease undergoing local anesthesia with 1.8mL of lidocaine 2% with or without epinephrine 1:100,000 during restorative dental treatment. METHODS: Maternal ambulatory blood pressure and electrocardiographic monitoring as well as cardiotocography of 31 patients with rheumatic heart disease were performed between the 28th and 37th week of gestation. The patients were divided into two groups, those with or without vasoconstrictor. RESULTS: A significant reduction in maternal heart rate was shown in both groups during the procedure in comparison with the other periods (p0.05. The same occurred (p>0.05 with the number of uterine contractions, baseline level and variability, and number of accelerations of fetal heart rate. CONCLUSION: The use of 1.8mL of lidocaine 2% in combination with epinephrine was safe and efficient in restorative dental procedures during

  1. Pathologic Evaluation of Type 2 Porcine Reproductive and Respiratory Syndrome Virus Infection at the Maternal-Fetal Interface of Late Gestation Pregnant Gilts.

    Directory of Open Access Journals (Sweden)

    Predrag Novakovic

    Full Text Available The pathogenesis of fetal death caused by porcine reproductive and respiratory syndrome virus (PRRSV remains unclear. The objective of this study was to improve our understanding of the pathogenesis by assessing potential relationships between specific histopathological lesions and PRRSV RNA concentration in the fetuses and the maternal-fetal interface. Pregnant gilts were inoculated with PRRSV (n = 114 or sham inoculated (n = 19 at 85±1 days of gestation. Dams and their litters were humanely euthanized and necropsied 21 days later. PRRSV RNA concentration was measured by qRT-PCR in the maternal-fetal interface and fetal thymus (n = 1391. Presence of fetal lesions was positively related to PRRSV RNA concentration in the maternal-fetal interface and fetal thymus (P<0.05 for both, but not to the distribution or severity of vasculitis, or the severity of endometrial inflammation. The presence of fetal and umbilical lesions was associated with greater odds of meconium staining (P<0.05 for both. The distribution and severity of vasculitis in endometrium were not significantly related to PRRSV RNA concentration in maternal-fetal interface or fetal thymus. Endometrial inflammation severity was positively related to distribution and severity of vasculitis in endometrium (P<0.001 for both. Conclusions from this study suggest that type 2 PRRSV infection in pregnant gilts induces significant histopathological lesions at maternal-fetal interface, but they are not associated with presence of PRRSV in the maternal-fetal interface at 21 days post infection. Conversely, fetal pathological lesions are associated with presence of PRRSV in the maternal-fetal interface and fetal thymus, and meconium staining is significantly associated with the presence of both fetal and umbilical lesions observed 21 days post infection.

  2. Pathologic Evaluation of Type 2 Porcine Reproductive and Respiratory Syndrome Virus Infection at the Maternal-Fetal Interface of Late Gestation Pregnant Gilts

    Science.gov (United States)

    Novakovic, Predrag; Harding, John C. S.; Al-Dissi, Ahmad N.; Ladinig, Andrea; Detmer, Susan E.

    2016-01-01

    The pathogenesis of fetal death caused by porcine reproductive and respiratory syndrome virus (PRRSV) remains unclear. The objective of this study was to improve our understanding of the pathogenesis by assessing potential relationships between specific histopathological lesions and PRRSV RNA concentration in the fetuses and the maternal-fetal interface. Pregnant gilts were inoculated with PRRSV (n = 114) or sham inoculated (n = 19) at 85±1 days of gestation. Dams and their litters were humanely euthanized and necropsied 21 days later. PRRSV RNA concentration was measured by qRT-PCR in the maternal-fetal interface and fetal thymus (n = 1391). Presence of fetal lesions was positively related to PRRSV RNA concentration in the maternal-fetal interface and fetal thymus (P<0.05 for both), but not to the distribution or severity of vasculitis, or the severity of endometrial inflammation. The presence of fetal and umbilical lesions was associated with greater odds of meconium staining (P<0.05 for both). The distribution and severity of vasculitis in endometrium were not significantly related to PRRSV RNA concentration in maternal-fetal interface or fetal thymus. Endometrial inflammation severity was positively related to distribution and severity of vasculitis in endometrium (P<0.001 for both). Conclusions from this study suggest that type 2 PRRSV infection in pregnant gilts induces significant histopathological lesions at maternal-fetal interface, but they are not associated with presence of PRRSV in the maternal-fetal interface at 21 days post infection. Conversely, fetal pathological lesions are associated with presence of PRRSV in the maternal-fetal interface and fetal thymus, and meconium staining is significantly associated with the presence of both fetal and umbilical lesions observed 21 days post infection. PMID:26963101

  3. An updated literature review on maternal-fetal and reproductive disorders of Toxoplasma gondii infection.

    Science.gov (United States)

    Fallahi, S; Rostami, A; Nourollahpour Shiadeh, M; Behniafar, H; Paktinat, S

    2018-03-01

    Toxoplasma gondii infection is one of the most prevalent infectious disease with worldwide distribution. Congenital toxoplasmosis is annually responsible for 1.20 million disability-adjusted life years around the world, but often it is overlooked many countries. We performed an updated review to summarize the current researches on fetal, neonatal and maternal consequences of T. gondii infection and also adverse effects of toxoplasmosis on women reproductive organs. T. gondii infection could be cause of several abnormalities from hydrocephalus, microcephaly, deafness, abortion and still birth in fetal to psychomotor retardation, intellectual disability, hearing loss, slower postnatal motor development during the first year of life; and chorioretinitis, cryptogenic epilepsy and autism spectrum disorders in newborns. Moreover, this infection is related with neuropsychiatric disorders such as anxiety, schizophrenia spectrum disorders, depression, decreased weight, autoimmune thyroid diseases, self-directed violence, violent suicide attempts in mothers. This literature review emphasized that toxoplasmosis could be an important neglected factor endometritis, ovarian dysfunction, impaired folliculogenesis, ovarian and uterine atrophy, decrease in reproductive organs weight and reproductive performance in women. We reviewed role of the immunological profile such as pro-infiammatory cytokines and hormonal changes as main potential mechanisms related to this infection and development of maternal-fetal and reproductive disorders. T. gondii is associated with several brain related disorders in both mothers and newborns, and also it is cause of several abnormalities in reproductive organs. Early diagnosis and treatment of the infection could be effective to significantly improve the clinical outcome. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. The relationship of maternal-fetal attachment and depression with social support in pregnant women referring to health centers of Tabriz-Iran, 2016.

    Science.gov (United States)

    Delavari, Mina; Mirghafourvand, Mojgan; Mohammad-Alizadeh-Charandabi, Sakineh

    2018-09-01

    The objective of this study was to determine the relationship of maternal-fetal attachment and depression during pregnancy with social support. This cross-sectional study was done on 287 primipara women. The data collection tools used included a demographic characteristics questionnaire, Maternal-Fetal Attachment Scale, the Edinburgh Postnatal Depression Scale and the Social Support Scale. Pearson's correlation test and general linear model were used for data analysis. The mean maternal-fetal attachment score was 90.0 (SD: 10.3). The highest score was obtained in the "role taking" domain and the lowest in the "interaction with the fetus" domain. The mean depression score was 8.5 (SD: 4.0). The score of perceived social support was 135.5 (SD: 15.6). Pearson's correlation test showed a significant positive correlation between social support and maternal-fetal attachment (r = 0.36, p social support and depression (r= -0.14, p = .018). The present study found a significant relationship between maternal-fetal attachment, depression and social support. It is recommended to devise plans for increasing the support given to women and to improve the society's and families' awareness about these issues in the attempt to have healthy mothers and thereby healthy families and communities.

  5. The Relationship between Maternal-Fetal Attachment and Mother-Infant Attachment Behaviors in Primiparous Women Referring to Mashhad Health Care Centers

    Directory of Open Access Journals (Sweden)

    Mahin Taffazoli

    2015-04-01

    Full Text Available Background & aim: Mother-infant bonding and interactions after childbirth are shaped by maternal-fetal attachment during pregnancy. Although many studies have shown the positive correlation between maternal-fetal attachment and mother-infant attachment behaviors, some controversial studies have shown otherwise. Therefore, this study aimed to evaluate the correlation between maternal-fetal attachment and mother-infant attachment behaviors in primiparous women. Methods:This descriptive correlational study was conducted on 100 primiparous women, referring to the selected heath care centers of Mashhad. Data were collected using Cranley's maternal–fetal attachment scale, Avant’s mother-infant attachment tool, Edinburgh postnatal depression scale, and a demographic/obstetric questionnaire including demographic data, obstetric information, delivery outcomes, and postpartum data. Pregnant women with a gestational age of 35-41 weeks, who met the inclusion criteria, completed Cranley's questionnaire, as well as the demographic/obstetric questionnaire. Four and eight weeks after delivery, the subjects were asked to complete the Edinburgh questionnaire and postpartum information; then, they were asked to breastfeed their infants on a chair in a quiet place for 15 minutes. The researcher observed the mothers’ behaviors toward their neonates. For data analysis, descriptive and analytical tests were performed, using SPSS version 16. Results: There was a direct positive relationship between maternal-fetal attachment and mothers’ emotional behaviors toward infants four and eight weeks after delivery. However, four and eight weeks after childbirth, no significant correlation was found between maternal-fetal attachment and mothers’ caring behaviors. Conclusion: According to the findings, maternal-fetal attachment is one of the most important factors for mother-infant attachment. These findings could be applied for enriching mother-infant attachment

  6. Effect of Bauhinia forficata aqueous extract on the maternal-fetal outcome and oxidative stress biomarkers of streptozotocin-induced diabetic rats.

    Science.gov (United States)

    Volpato, G T; Damasceno, D C; Rudge, M V C; Padovani, C R; Calderon, I M P

    2008-02-28

    Bauhinia forficata Link, commonly known as "paw-of-cow", is widely used in Brazilian folk medicine for the treatment of diabetes. To evaluate the effect of Bauhinia forficata treatment on maternal-fetal outcome and antioxidant systems of streptozotocin-induced diabetic rats. Virgin female Wistar rats were injected with 40 mg/kg streptozotocin before mating. Oral administration of an aqueous extract of Bauhinia forficata leaves was given to non-diabetic and diabetic pregnant rats at increasing doses: 500 mg/kg from 0 to 4th day of pregnancy, 600 mg/kg from 5th to 14th day and 1000 mg/kg from 15th to 20th day. At day 21 of pregnancy the rats were anaesthetized with ether and a maternal blood sample was collected for the determination superoxide dismutase (SOD) and reduced glutathione (GSH). The gravid uterus was weighed with its contents and fetuses were analyzed. The data showed that the diabetic dams presented an increased glycemic level, resorption, placental weight, placental index, and fetal anomalies, and reduced GSH and SOD determinations, live fetuses, maternal weight gain, gravid uterine weight, and fetal weight. It was also verified that Bauhinia forficata treatment had no hypoglycemic effect, did not improve maternal outcomes in diabetic rats, but it contributed to maintain GSH concentration similarly to non-diabetic groups, suggesting relation with the decreased incidence of visceral anomalies.

  7. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  8. Dotting the I's and crossing the T's : autonomy and/or beneficence? The 'fetus as a patient' in maternal-fetal surgery

    NARCIS (Netherlands)

    Rodrigues, H. Catarina M. L.; van den Berg, Paul P.; Duwell, Marcus

    Chervenak and McCullough, authors of the most acknowledged ethical framework for maternal-fetal surgery, rely on the 'ethical-obstetrical' concept of the fetus as a patient in order to determine what is morally owed to fetuses by both physicians and the women who gestate them in the context of

  9. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  10. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  11. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  12. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  13. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  14. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  15. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  16. The Effect of Education of Fetal Movement Counting on Maternal-Fetal Attachment in the Pregnant Women: a Randomized Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Kobra Salehi

    2017-04-01

    Full Text Available Background Prenatal care is a good opportunity for evaluating and improving maternal-fetal attachment. In the present study the effect of early education of fetal movement counting in the second trimester on maternal-fetal attachment was evaluated. Materials and Methods 52 eligible pregnant women were selected through simple sampling and then randomly allocated into control (n=29, and intervention groups (n=23. First, demographic characteristics questionnaire and Cranely’s Maternal-Fetal Attachment Scale (MFAS, were completed by pregnant women. Face to face training about counting and recording the daily fetal movement was provided in the intervention group and from the 24th to 28th weeks of pregnancy, daily counting of fetal movements were conducted. Then at the end of the 28th week of pregnancy, MFAS was again completed by both groups. Data analysis was conducted using SPSS version16.0. Results The mean score of MFA scale in the intervention group was 86.63±11.62 and in the control group was 87.48±10.31 (total score of 120. No significant difference was observed between two groups. After the intervention, the mean score of MFA was increased to 96.30±10.81 in the intervention group and 88.64±10.31 in the control group. The difference was statistically significant between two groups (P

  17. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  18. Progesterone promotes maternal-fetal tolerance by reducing human maternal T-cell polyfunctionality and inducing a specific cytokine profile.

    Science.gov (United States)

    Lissauer, David; Eldershaw, Suzy A; Inman, Charlotte F; Coomarasamy, Aravinthan; Moss, Paul A H; Kilby, Mark D

    2015-10-01

    Progesterone is a steroid hormone essential for the maintenance of human pregnancy, and its actions are thought to include promoting maternal immune tolerance of the semiallogenic fetus. We report that exposure of maternal T cells to progesterone at physiological doses induced a unique skewing of the cytokine production profile of CD4(+) and CD8(+) T cells, with reductions not only in potentially deleterious IFN-γ and TNF-α production but also in IL-10 and IL-5. Conversely, production of IL-4 was increased. Maternal T cells also became less polyfunctional, focussing cytokine production toward profiles including IL-4. This was accompanied by reduced T-cell proliferation. Using fetal and viral antigen-specific CD8(+) T-cell clones, we confirmed that this as a direct, nonantigen-specific effect. Yet human T cells lacked conventional nuclear progesterone receptors, implicating a membrane progesterone receptor. CD4(+) and CD8(+) T cells responded to progesterone in a dose-dependent manner, with subtle effects at concentrations comparable to those in maternal blood, but profound effects at concentrations similar to those at the maternal-fetal interface. This characterization of how progesterone modulates T-cell function is important in understanding the normal biology of pregnancy and informing the rational use of progesterone therapy in pregnancies at risk of fetal loss. © 2015 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. War trauma and maternal-fetal attachment predicting maternal mental health, infant development, and dyadic interaction in Palestinian families.

    Science.gov (United States)

    Punamäki, Raija-Leena; Isosävi, Sanna; Qouta, Samir R; Kuittinen, Saija; Diab, Safwat Y

    2017-10-01

    Optimal maternal-fetal attachment (MFA) is believed to be beneficial for infant well-being and dyadic interaction, but research is scarce in general and among risk populations. Our study involved dyads living in war conditions and examined how traumatic war trauma associates with MFA and which factors mediate that association. It also modeled the role of MFA in predicting newborn health, infant development, mother-infant interaction, and maternal postpartum mental health. Palestinian women from the Gaza Strip (N = 511) participated during their second trimester (T1), and when their infants were 4 (T2) and 12 (T3) months. Mothers reported MFA (interaction with, attributions to, and fantasies about the fetus), social support, and prenatal mental health (post-traumatic stress disorder, depression, and anxiety) at T1, newborn health at T2, and the postpartum mental health, infant's sensorimotor and language development, and mother-infant interaction (emotional availability) at T3. Results revealed, first, that war trauma was not directly associated with MFA but that it was mediated through a low level of social support and high level of maternal prenatal mental health problems. Second, intensive MFA predicted optimal mother-reported infant's sensorimotor and language development and mother-infant emotional availability but not newborn health or maternal postpartum mental health.

  20. Endogenous lysophosphatidic acid participates in vascularisation and decidualisation at the maternal-fetal interface in the rat.

    Science.gov (United States)

    Sordelli, Micaela S; Beltrame, Jimena S; Zotta, Elsa; Gomez, Natalia; Dmytrenko, Ganna; Sales, María Elena; Blois, Sandra M; Davio, Carlos; Martinez, Silvina Perez; Franchi, Ana M; Ribeiro, María L

    2017-10-01

    Lysophosphatidic acid (LPA) affects several female reproductive functions through G-protein-coupled receptors. LPA contributes to embryo implantation via the lysophospholipid LPA 3 receptor. In the present study we investigated the participation of endogenous LPA signalling through the LPA 3 receptor in vascularisation and decidualisation, two crucial events at the maternal-fetal interface. Pregnant rats were treated with diacylglycerol pyrophosphate (DGPP), a highly selective antagonist of LPA 3 receptors, on Day 5 of gestation. Pregnant rats received intrauterine (i.u.) injections of single doses of DGPP (0.1mgkg -1 ) in a total volume of 2μL in the left horn (treated horn) in the morning of GD5. DGPP treatment produced aberrant embryo spacing and increased embryo resorption. The LPA 3 receptor antagonist decreased the cross-sectional length of the uterine and arcuate arteries and induced histological anomalies in the decidua and placentas. Marked haemorrhagic processes, infiltration of immune cells and tissue disorganisation were observed in decidual and placental tissues from sites of resorption. The mRNA expression of three vascularisation markers, namely interleukin 10 (Il10), vascular endothelial growth factor (Vegfa) and vascular endothelial growth factor receptor 1 (Vegfr1), was reduced at sites of resorption from Day 8. The results show that the disruption of endogenous LPA signalling by blocking the LPA 3 receptor modified the development of uterine vessels with consequences in the formation of the decidua and placenta and in the growth of embryos.

  1. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  2. Improving Perinatal Care in the Rural Regions Worldwide by Wireless Enabled Antepartum Fetal Monitoring: A Demonstration Project

    Directory of Open Access Journals (Sweden)

    Roberto Tapia-Conyer

    2015-01-01

    Full Text Available Background. Fetal and neonatal morbidity and mortality are significant problems in developing countries; remote maternal-fetal monitoring offers promise in addressing this challenge. The Gary and Mary West Health Institute and the Instituto Carlos Slim de la Salud conducted a demonstration project of wirelessly enabled antepartum maternal-fetal monitoring in the state of Yucatán, Mexico, to assess whether there were any fundamental barriers preventing deployment and use. Methods. Following informed consent, high-risk pregnant women at 27–29 weeks of gestation at the Chemax primary clinic participated in remote maternal-fetal monitoring. Study participants were randomized to receive either prototype wireless monitoring or standard-of-care. Feasibility was evaluated by assessing technical aspects of performance, adherence to monitoring appointments, and response to recommendations. Results. Data were collected from 153 high-risk pregnant indigenous Mayan women receiving either remote monitoring (n=74 or usual standard-of-care (n=79. Remote monitoring resulted in markedly increased adherence (94.3% versus 45.1%. Health outcomes were not statistically different in the two groups. Conclusions. Remote maternal-fetal monitoring is feasible in resource-constrained environments and can improve maternal compliance for monitoring sessions. Improvement in maternal-fetal health outcomes requires integration of such technology into sociocultural context and addressing logistical challenges of access to appropriate emergency services.

  3. Improving Perinatal Care in the Rural Regions Worldwide by Wireless Enabled Antepartum Fetal Monitoring: A Demonstration Project

    Science.gov (United States)

    Tapia-Conyer, Roberto; Lyford, Shelley; Saucedo, Rodrigo; Casale, Michael; Gallardo, Hector; Becerra, Karen; Mack, Jonathan; Mujica, Ricardo; Estrada, Daniel; Sanchez, Antonio; Sabido, Ramon; Meier, Carlos; Smith, Joseph

    2015-01-01

    Background. Fetal and neonatal morbidity and mortality are significant problems in developing countries; remote maternal-fetal monitoring offers promise in addressing this challenge. The Gary and Mary West Health Institute and the Instituto Carlos Slim de la Salud conducted a demonstration project of wirelessly enabled antepartum maternal-fetal monitoring in the state of Yucatán, Mexico, to assess whether there were any fundamental barriers preventing deployment and use. Methods. Following informed consent, high-risk pregnant women at 27–29 weeks of gestation at the Chemax primary clinic participated in remote maternal-fetal monitoring. Study participants were randomized to receive either prototype wireless monitoring or standard-of-care. Feasibility was evaluated by assessing technical aspects of performance, adherence to monitoring appointments, and response to recommendations. Results. Data were collected from 153 high-risk pregnant indigenous Mayan women receiving either remote monitoring (n = 74) or usual standard-of-care (n = 79). Remote monitoring resulted in markedly increased adherence (94.3% versus 45.1%). Health outcomes were not statistically different in the two groups. Conclusions. Remote maternal-fetal monitoring is feasible in resource-constrained environments and can improve maternal compliance for monitoring sessions. Improvement in maternal-fetal health outcomes requires integration of such technology into sociocultural context and addressing logistical challenges of access to appropriate emergency services. PMID:25691900

  4. System health monitoring

    International Nuclear Information System (INIS)

    Reneke, J.A.; Fryer, M.O.

    1995-01-01

    Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection

  5. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  6. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  7. Celecoxib restores angiogenic factor expression at the maternal-fetal interface in the BPH/5 mouse model of preeclampsia.

    Science.gov (United States)

    Reijnders, Dorien; Liu, Chin-Chi; Xu, Xinjing; Zhao, Anna M; Olson, Kelsey N; Butler, Scott D; Douglas, Nataki C; Sones, Jenny L

    2018-05-01

    Preeclampsia (PE), a hypertensive disease of pregnancy, is a leading cause of fetal and maternal morbidity/mortality. Early angiogenic and inflammatory disturbances within the placenta are thought to underlie the development of the maternal PE syndrome and poor pregnancy outcomes. However, the exact etiology remains largely unknown. Here, we use the BPH/5 mouse model of PE to elucidate the way in which inflammation early in pregnancy contributes to abnormal expression of angiogenic factors at the maternal-fetal interface. We have previously described improvement in maternal hypertension and fetal growth restriction in this model after treatment with the anti-inflammatory cyclooxygenase-2 (Cox2) specific inhibitor celecoxib. To further characterize the mechanisms by which celecoxib improves poor pregnancy outcomes in BPH/5 mice, we determined expression of angiogenic factors and complement pathway components after celecoxib. In BPH/5 implantation sites there was increased hypoxia inducible factor-1α ( Hif1α), heme oxygenase-1 ( Ho-1), and stem cell factor ( Scf) mRNA concomitant with elevated prostaglandin synthase 2 ( Ptgs2), encoding Cox2, and elevated VEGF protein. Angiopoietin 1 ( Ang1), tunica interna endothelial cell kinase-2 receptor ( Tie2), complement factor 3 ( C3), and complement factor B ( CfB) were increased in midgestation BPH/5 placentae. Whereas BPH/5 expression levels of VEGF, Ang1, and Tie2 normalized after celecoxib, placental C3 and CfB mRNA remained unchanged. However, celecoxib did reduce the pregnancy-specific circulating soluble fms-like tyrosine kinase-1 (sFlt-1) rise in BPH/5 mice at midgestation. These data show that elevated Cox2 during implantation contributes to placental angiogenic factor imbalances in the BPH/5 mouse model of PE.

  8. Icinga Monitoring System Interface

    CERN Document Server

    Neculae, Alina Georgiana

    2014-01-01

    The aim of this project is to develop a web interface that would be used by the Icinga monitoring system to manage the CMS online cluster, in the experimental site. The interface would allow users to visualize the information in a compressed and intuitive way, as well as modify the information of each individual object and edit the relationships between classes.

  9. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  10. Maternal-fetal acute responses to two moderate-intensity exercise types: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Jousilene de Sales Tavares

    2018-03-01

    Full Text Available Objective:  This study aims to compare maternal and fetal responses during two physical exercise types. Design:  A randomized clinical trial compared 120 pregnant women, gestational age of 35-37 weeks, 56 exercising on a stationary bicycle (Group A and 64 on a treadmill (Group B. Methods: Participants were monitored for three 20-minute phases: resting, exercise and recovery.  Fetal heart rate (FHR and maternal heart rate (MHR were monitored.  Glucose and lactate levels were evaluated at rest and during exercise. Results:  After the beginning of exercise, maximum lactate (L levels were reached at 20 minutes and never exceeded 4 mmol/l.  FHR decreased by 22 bpm during exercise in relation to resting values, irrespective of the exercise type (p0.05, increasing at 20’ to 32% and 40.6%, respectively, (p>0.05.  The FHR decrease during exercise was accompanied by a simultaneous increase in its variability (p<0.001, nevertheless a rapid return to resting values was observed shortly after exercise end.  Glucose decreased in both groups irrespective of the exercise type (85 mg/dl at rest; 79 mg/dl during exercise and 81 mg/dl during recovery; p<0.001. There were no hypoglycemia cases. Conclusions: FHR variability increase and the rapid return to resting values after exercise suggests that the FHR fall and the presence of bradycardia during exercise is the fetal physiologic response to blood flow redistribution, with maintenance of fetal well-being. Key-words: Exercise; fetal heart rate; glucose; maternal heart rate; pregnancy Clinical Trial Registration: ClinicalTrials.gov, www.clinicaltrials.gov, NCT01383889.

  11. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  12. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  13. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  14. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  15. The frequency of ABO blood group maternal-fetal incompatibility, maternal iso-agglutinins, and immune agglutinins quantitation in Osogbo, Osun State, South-West of Nigeria

    Directory of Open Access Journals (Sweden)

    Oseni Bashiru

    2011-01-01

    Full Text Available Background : ABO incompatibility in maternal-fetal relationship has been shown to cause hemolytic disease of the newborn (HDNB; a survey which is not yet done in this locality. Aim: Frequency of ABO blood group maternal-fetal incompatibility, maternal iso-agglutinins, and immune agglutinins quantitation was carried out in Osogbo, Osun State, South-West of Nigeria. Settings and Designs : A total of 260 subjects comprising 130 postpartum mothers within the age range of 22-35 years having good obstetrics history and normal delivery, with their 130 neonate babies were used for the study. Materials and Methods : ABO cell and serum groupings were carried out on the subjects using standard antisera and cells with appropriate controls. Direct Coomb′s Test was carried out on neonate red cells. Antibody quantitation by double dilution on the maternal serum using red cells containing corresponding antigen to the antibody was determined. A titer, which is the reciprocal of the highest dilution showing agglutination by Indirect Coombs Test, was determined. Another batch of sera was pretreated with 2-mecarptoethanol before determining the titer. Statistical Analysis: The distribution study results obtained were compared in percentages, whereas the antibodies quantitation was expressed as titers using the mode of the titers for compariso-agglutininsn. Results and Conclusions : Thirty-eight percent (50 mothers were ABO incompatible with their babies, whereas 62% (80 mothers were compatible. The distribution of blood groups in the compatible population showed blood group O (45%; A (30%; B (20%; and AB (5%. Mothers O, A, and B carrying incompatible babies had a frequency of 24% each, whereas mothers AB had 28%. Serologist differences occur in maternal ABO antibodies of corresponding incompatible baby ABO antigens. A high incidence of ABO maternal-fetal incompatibility observed without detection of immune agglutinins is indicative of a rare incidence of HDNB due

  16. Predictive value of vaginal IL-6 and TNFα bedside tests repeated until delivery for the prediction of maternal-fetal infection in cases of premature rupture of membranes.

    Science.gov (United States)

    Kayem, Gilles; Batteux, Frederic; Girard, Noémie; Schmitz, Thomas; Willaime, Marion; Maillard, Francoise; Jarreau, Pierre Henri; Goffinet, Francois

    2017-04-01

    Examine the predictive value for maternal-fetal infection of routine bedside tests detecting the proinflammatory cytokines, TNFα and IL-6, in the vaginal secretions of women with premature rupture of the membranes (PROM). This prospective two-center cohort study included all women hospitalized for PROM over a 2-year period. A bedside test assessed IL-6 and TNFα in vaginal secretions. Both centers routinely tested CRP and leukocytes, assaying both in maternal serum, and analyzed vaginal bacterial flora; all samples were repeated twice weekly until delivery. The study included 689 women. In cases of preterm PROM (PPROM) before 37 weeks (n=184), a vaginal sample positive for one or more bacteria was the only marker associated with early neonatal infection (OR 5.6, 95%CI; 2.0-15.7). Its sensitivity was 82% (95%CI; 62-94) and its specificity 56% (95%CI; 47-65). All positive markers of infection were associated with the occurrence of chorioamnionitis. In cases of PROM from 37 weeks onward (n=505), only CRP >5mg/dL was associated with early neonatal infection (OR=8.3, 95%CI; 1.1-65.4) or clinical chorioamnionitis (OR=6.8, 95%CI; 1.5-30.0). The sensitivity of CRP >5mg/dL was 91% (95%CI; 59-100) and its specificity 45% (95%CI; 40-51) for predicting early neonatal infection, and 89% (95%CI; 65-99) and 46% (95%CI; 41-51), respectively, for predicting clinical chorioamnionitis. The association of vaginal cytokines with maternal-fetal infection is weak and thus prevents their use as a good predictor of maternal-fetal infection. CRP and vaginal samples may be useful for identifying a group of women at low risk of infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Syphilis during pregnancy: a preventable threat to maternal-fetal health.

    Science.gov (United States)

    Rac, Martha W F; Revell, Paula A; Eppes, Catherine S

    2017-04-01

    dose of benzathine penicillin G in a labor and delivery department under continuous fetal monitoring for at least 24 hours. Thereafter, the remaining benzathine penicillin G doses can be given in an outpatient setting. The rate of maternal titer decline is not tied to pregnancy outcomes. Therefore, after adequate syphilotherapy, maternal titers should be checked monthly to ensure they are not increasing four-fold, as this may indicate reinfection or treatment failure. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Alpha-monitoring system

    International Nuclear Information System (INIS)

    Dincklage, R.D. von

    1982-01-01

    A continuously operating and fast system for the monitoring of radiactive materials is outlined. Its application to nuclear technology particularly to reprocessing is emphasized. Using high-resolution α-ray spectrocopy and the gas-jet method for the rapid transportation of the radionuclides to the solid state detectors makes detection limits as low as 0.2 μg/cm 3 for Pu-239 feasible. (orig.)

  19. Nuclear reactor monitoring system

    International Nuclear Information System (INIS)

    Drummond, C.N.; Bybee, R.T.; Mason, F.L.; Worsham, H.J.

    1976-01-01

    The invention pertains to an improved monitoring system for the neutron flux in a nuclear reactor. It is proposed to combine neutron flux detectors, a thermoelement, and a background radiation detector in one measuring unit. The spatial arrangement of these elements is fixed with great exactness; they are enclosed by an elastic cover and are brought into position in the reactor with the aid of a bent tube. The arrangement has a low failure rate and is easy to maintain. (HP) [de

  20. RTP Radiation Monitoring System

    International Nuclear Information System (INIS)

    Alfred, S.L.; Mohd Fairus Abdul Farid; Ahmad Nabil Abdul Rahim; Nurhayati Ramli

    2015-01-01

    Radiation Monitoring System aiming to limiting dose exposed to personnel to the lowest level referring to the concept of ALARA (As Low As Reasonably Achievable). Atomic Energy Licensing (Basic Safety Radiation Protection) Regulation 2010 (Act 304) is a baseline to control employee and public radiation protection program and guideline, as well as to meet the requirement of the Occupational Safety and Health 1994 (Act 514). (author)

  1. Application of a Consumer Health Information Needs Taxonomy to Questions in Maternal-Fetal Care.

    Science.gov (United States)

    Shenson, Jared A; Ingram, Ebone; Colon, Nadja; Jackson, Gretchen Purcell

    2015-01-01

    Pregnancy is a time when expectant mothers may have numerous questions about their unborn children, especially when congenital anomalies are diagnosed prenatally. We sought to characterize information needs of pregnant women seen in the Vanderbilt Children's Hospital Fetal Center. Participants recorded questions from diagnosis through delivery. Questions were categorized by two researchers using a hierarchical taxonomy describing consumer health information needs. Consensus category assignments were made, and inter-rater reliability was measured with Cohen's Kappa. Sixteen participants reported 398 questions in 39 subcategories, of which the most common topics were prognosis (53 questions; 13.3%) and indications for intervention (31 questions; 7.8%). Inter-rater reliability of assignments showed moderate (κ=0.57) to substantial (κ=0.75) agreement for subcategories and primary categories, respectively. Pregnant women with prenatal diagnoses have diverse unmet information needs; a taxonomy of consumer health information needs may improve the ability to meet such needs through content and system design.

  2. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  3. Does maternal-fetal transfer of creatine occur in pregnant sheep?

    Science.gov (United States)

    Baharom, Syed; De Matteo, Robert; Ellery, Stacey; Della Gatta, Paul; Bruce, Clinton R; Kowalski, Greg M; Hale, Nadia; Dickinson, Hayley; Harding, Richard; Walker, David; Snow, Rodney J

    2017-07-01

    Our aim was to determine the disposition of creatine in ovine pregnancy and whether creatine is transferred across the placenta from mother to fetus. Pregnant ewes received either 1 ) a continuous intravenous infusion of creatine monohydrate or saline from 122 to 131 days gestation, with maternal and fetal arterial blood and amniotic fluid samples collected daily for creatine analysis and fetal tissues collected at necropsy at 133 days for analysis of creatine content, or 2 ) a single systemic bolus injection of [ 13 C]creatine monohydrate at 130 days of gestation, with maternal and fetal arterial blood, uterine vein blood, and amniotic fluid samples collected before and for 4 h after injection and analyzed for creatine, creatine isotopic enrichment, and guanidinoacetic acid (GAA; precursor of creatine) concentrations. Presence of the creatine transporter-1 (SLC6A8) and l-arginine:glycine amidinotransferase (AGAT; the enzyme synthesizing GAA) proteins were determined by Western blots of placental cotyledons. The 10-day creatine infusion increased maternal plasma creatine concentration three- to fourfold ( P creatine content. Maternal arterial 13 C enrichment was increased ( P creatine injection without change of fetal arterial 13 C enrichment. SLC6A8 and AGAT proteins were identified in placental cotyledons, and GAA concentration was significantly higher in uterine vein than maternal artery plasma. Despite the presence of SLC6A8 protein in cotyledons, these results suggest that creatine is not transferred from mother to fetus in near-term sheep and that the ovine utero-placental unit releases GAA into the maternal circulation. Copyright © 2017 the American Physiological Society.

  4. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  5. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  6. Storage monitoring system - 1997

    International Nuclear Information System (INIS)

    Mickelsen, B.; Nilsen, C.; Kinzel, R.; Davidson, B.; Pollock, R.

    1999-01-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use 1 of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them. (author)

  7. Storage monitoring system - 1997

    International Nuclear Information System (INIS)

    Mickelsen, B.; Nilsen, C.; Kinzel, R.; Davidson, B.; Pollock, R.

    1997-01-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them

  8. Airborne monitoring system

    International Nuclear Information System (INIS)

    Kadmon, Y.; Gabovitch, A.; Tirosh, D.; Ellenbogen, M.; Mazor, T.; Barak, D.

    1997-01-01

    A complete system for tracking, mapping, and performing a composition analysis of a radioactive plume and contaminated area was developed at the NRCN. The system includes two major units : An airborne unit for monitoring and a ground station for analyzing. The airborne unit is mounted on a helicopter and includes file following. Four radiation sensor, two 2'' x 2'' Nal (Tl) sensors horizontally separated by lead shield for mapping and spectroscopy, and two Geiger Mueller (GM) tubes as part of the safety system. A multichannel analyzer card is used for spectroscopy. A navigation system, based on GPS and a barometric altitude meter, is used to locate the plume or ground data. The telemetry system, consisting of a transceiver and a modem, transfers all the data in real time to the ground station. An industrial PC (Field Works) runs a dedicated C++ Windows application to manage the acquired data. An independent microprocessor based backup system includes a recorder, display, and key pad. The ground station is based on an industrial PC, a telemetry system, a color printer and a modem to communicate with automatic meteorology stations in the relevant area. A special software controls the ground station. Measurement results are analyzed in the ground station to estimate plume parameters including motion, location, size, velocity, and perform risk assessment. (authors)

  9. Plant monitor system

    International Nuclear Information System (INIS)

    Scarola, K.; Jamison, D.; Manazir, R.; Rescori, R.; Harmon, D.

    1991-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system which is nuclear qualified for rapid response to changes in plant parameters and a component control system which together provide a discrete monitoring and control capability at a panel in the control room. A separate data processing system, which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs and a large, overhead integrated process status overview board. The discrete indicator and alarm system and the data processing system receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the main machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof. (author)

  10. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  11. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  12. Environmental monitoring and information systems

    International Nuclear Information System (INIS)

    Gibbert, R.

    1998-01-01

    Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)

  13. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  14. Life Support Systems: Environmental Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems (AES) Life Support Systems project Environmental Monitoring (EM) systems task objectives are to develop and demonstrate onboard...

  15. Ultrasonic monitoring system

    International Nuclear Information System (INIS)

    McLain, R.E.

    1975-01-01

    The ultrasonic monitoring system is used in LMFBR's, BWR's or PWR's. A remotely controlled, movable instrument carrier may be used which contains the piezo-electric transducer and is connected to the main control console by a transmission cable. An excitation pulse coming from a pulse generator is used to excite the transducer with a maximum of energy, independent of the length of the transmission line. Pulse width and pulse amplitude can be set without any direct interference into the transducer. For this purpose, a resistor whose impedance has been matched to that of the transmission line is connected to the input of the transmission line. Moreover, a capacitor for generation of the excitation pulse is coupled with the transmission line by means of a four-layer switching diode and is discharged. For termination of the excitation and the control pulses, respectively, another four-layer switching diode connected parallel to the capacitor quickly discharges the capacitor. The capacitor and the capacitance of the line constitute a voltage divider. In this way it is possible to change the length of the transmission line and, to safeguard the generation of a pulse of the desired amplitude, only vary the capacitance of the capacitor. (DG/RF) [de

  16. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  17. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  18. Early Life Exposure to Fructose Alters Maternal, Fetal and Neonatal Hepatic Gene Expression and Leads to Sex-Dependent Changes in Lipid Metabolism in Rat Offspring

    Science.gov (United States)

    Clayton, Zoe E.; Vickers, Mark H.; Bernal, Angelica; Yap, Cassandra; Sloboda, Deborah M.

    2015-01-01

    Aim Fructose consumption is associated with altered hepatic function and metabolic compromise and not surprisingly has become a focus for perinatal studies. We have previously shown that maternal fructose intake results in sex specific changes in fetal, placental and neonatal outcomes. In this follow-up study we investigated effects on maternal, fetal and neonatal hepatic fatty acid metabolism and immune modulation. Methods Pregnant rats were randomised to either control (CON) or high-fructose (FR) diets. Fructose was given in solution and comprised 20% of total caloric intake. Blood and liver samples were collected at embryonic day 21 (E21) and postnatal day (P)10. Maternal liver samples were also collected at E21 and P10. Liver triglyceride and glycogen content was measured with standard assays. Hepatic gene expression was measured with qPCR. Results Maternal fructose intake during pregnancy resulted in maternal hepatic ER stress, hepatocellular injury and increased levels of genes that favour lipogenesis. These changes were associated with a reduction in the NLRP3 inflammasome. Fetuses of mothers fed a high fructose diet displayed increased hepatic fructose transporter and reduced fructokinase mRNA levels and by 10 days of postnatal age, also have hepatic ER stress, and elevated IL1β mRNA levels. At P10, FR neonates demonstrated increased hepatic triglyceride content and particularly in males, associated changes in the expression of genes regulating beta oxidation and the NLRP3 inflammasome. Further, prenatal fructose results in sex-dependant changes in levels of key clock genes. Conclusions Maternal fructose intake results in age and sex-specific alterations in maternal fetal and neonatal free fatty acid metabolism, which may be associated in disruptions in core clock gene machinery. How these changes are associated with hepatic inflammatory processes is still unclear, although suppression of the hepatic inflammasome, as least in mothers and male neonates may

  19. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  20. Plant monitoring system

    International Nuclear Information System (INIS)

    Tamaoki, Tetsuo.

    1994-01-01

    The memory means of the present invention memorize conditions for analyzing a sampling period for inputting process signals and time sequential data of the process signals. The process signals are analyzed following after sampling period and the analysis conditions stored in the memory means preceding to monitoring. A monitoring condition setting means controls and subsequently updates the sampling period and the analysis conditions in the memory means based on the analysis data, to finally set monitoring conditions. With such procedures, analysis conditions such as optimum analysis frequency range, signal sampling period and correlational characteristics between process noise signals are automatically selected. (I.S.)

  1. Integrated photovoltaic (PV) monitoring system

    Science.gov (United States)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  2. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  3. Maintenance of radiation monitoring systems

    International Nuclear Information System (INIS)

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  4. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  5. Unattended Monitoring System Design Methodology

    International Nuclear Information System (INIS)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-01-01

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations

  6. Neutron monitoring system

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Arita, Setsuo.

    1994-01-01

    The present invention concerns neutron monitoring for monitoring reactor power, and presents a generation state of abnormal signals by monitoring output signals from neutron sensors, judges abnormal signals at an excessively high level outputted from the sensors to a measuring operator or a reactor operator. That is, a threshold value judging means judges whether a sensor signal exceeds a predetermined threshold value or not. When it exceeds the value, recognition signals are outputted to a memory means. The memory means memorizes the times of input of the recognition signals on every period of interval signals outputted from a reference signal generation means. The memory content of the memory means and the previously inputted hysteresis of the sensor are compared and judged, to determine the extent of the degradation of the sensors and output the result of the judgement and hysteresis information to the display means. The input means accesses to the judging means and the memory means to retrieve and correct the content of the memory means and the hysteresis information inputted to the judging means. (I.S.)

  7. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  8. Radiation monitoring system

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino

    2015-01-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  9. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  10. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  11. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  12. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  13. A blade deflection monitoring system

    DEFF Research Database (Denmark)

    2017-01-01

    A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...

  14. Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor)

    2017-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to control communication of data, via the bus, with each of the plurality of data acquisition modules.

  15. The JOYO remote monitoring system

    International Nuclear Information System (INIS)

    Damico, Joseph P.; Hashimoto, Yu

    2000-01-01

    The evolution of the personal computer, operating systems and applications software and the Internet has brought drastic change and many benefits worldwide. Remote monitoring systems benefit from computer network and other modern software technologies. The availability of fast, inexpensive and secure communications enables new solutions for monitoring system applications. The JOYO Remote Monitoring System (RMS) utilizes computer network communications and modular software design to provide a distributed integrated solution for monitoring multiple storage locations. This paper describes the remote monitoring system installed at the JOYO Fast Reactor. The system combines sensors, software, and computer network technologies to create a powerful data collection, storage and dissemination capability. The RMS provides a flexible, scalable solution for a variety of applications. The RMS integrates a variety of state of the art technologies from several sources and serves as a test bed for cutting edge technologies that can be shared with outside users. This paper describes the system components and their operation and discusses system benefits. Current activities and future plants for the JOYO RMS will be discussed. (author)

  16. ELECTRONIC FILE MONITORING SYSTEM

    African Journals Online (AJOL)

    GBUBEMI

    2014-11-06

    Nov 6, 2014 ... The result of the developed system shows a simple and effective graphic user interface ... business transactions, decision-making records and storage of .... Start. Input username and password. Access denied was login.

  17. A Grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin [Fermi National Accelerator Laboratory (United States); Nowack, Andreas [RWTH Aachen (Germany); Padhi, Sanjay [University of California San Diego (United States); Sarkar, Subir, E-mail: subir.sarkar@cern.c [INFN, Sezione di Pisa and Scuola Normale Superiore, Pisa (Italy)

    2010-04-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  18. A grid job monitoring system

    International Nuclear Information System (INIS)

    Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  19. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  20. UAV Delivery Monitoring System

    Directory of Open Access Journals (Sweden)

    San Khin Thida

    2018-01-01

    Full Text Available UAV-based delivery systems are increasingly being used in the logistics field, particularly to achieve faster last-mile delivery. This study develops a UAV delivery system that manages delivery order assignments, autonomous flight operation, real time control for UAV flights, and delivery status tracking. To manage the delivery item assignments, we apply the concurrent scheduler approach with a genetic algorithm. The present paper describes real time flight data based on a micro air vehicle communication protocol (MAVLink. It also presents the detailed hardware components used for the field tests. Finally, we provide UAV component analysis to choose the suitable components for delivery in terms of battery capacity, flight time, payload weight and motor thrust ratio.

  1. Prenatal Detection of Cardiac Anomalies in Fetuses with Single Umbilical Artery: Diagnostic Accuracy Comparison of Maternal-Fetal-Medicine and Pediatric Cardiologist

    Directory of Open Access Journals (Sweden)

    Ilir Tasha

    2014-01-01

    Full Text Available Aim. To determine agreement of cardiac anomalies between maternal fetal medicine (MFM physicians and pediatric cardiologists (PC in fetuses with single umbilical artery (SUA. Methods. A retrospective review of all fetuses with SUA between 1999 and 2008. Subjects were studied by MFM and PC, delivered at our institution, and had confirmation of SUA and cardiac anomaly by antenatal and neonatal PC follow-up. Subjects were divided into four groups: isolated SUA, SUA and isolated cardiac anomaly, SUA and multiple anomalies without heart anomalies, and SUA and multiple malformations including cardiac anomaly. Results. 39,942 cases were studied between 1999 and 2008. In 376 of 39,942 cases (0.94%, SUA was diagnosed. Only 182 (48.4% met inclusion criteria. Cardiac anomalies were found in 21% (38/182. Agreement between MFM physicians and PC in all groups combined was 94% (171/182 (95% CI [89.2, 96.8]. MFM physicians overdiagnosed cardiac anomalies in 4.4% (8/182. MFM physicians and PC failed to antenatally diagnose cardiac anomaly in the same two cases. Conclusions. Good agreement was noted between MFM physicians and PC in our institution. Studies performed antenatally by MFM physicians and PC are less likely to uncover the entire spectrum of cardiac abnormalities and thus neonatal follow-up is suggested.

  2. Predictive value of cord blood bilirubins for hyperbilirubinemia in neonates at risk for maternal-fetal blood group incompatibility and hemolytic disease of the newborn

    Science.gov (United States)

    Calkins, Kara L.; Roy, Devika; Molchan, Lauren; Bradley, Lyndsey; Grogan, Tristan; Elashoff, David; Walker, Valencia P.

    2015-01-01

    Objective To determine the predictive ability of cord blood bilirubin (CBB) for hyperbilirubinemia in a population at risk for maternal-fetal blood group incompatibility and hemolytic disease of the newborn. Study Design This is a single center retrospective case-control study. Cases received phototherapy; controls did not. Cases were matched 1:3 to controls by gender and treating physician. Inclusion criteria included: ≥ 35 weeks gestation, CBB, and one or more total serum bilirubin (TSB) concentrations. The primary outcome was CBB. Secondary outcomes were a TSB > 75th percentile, length of stay, and neonatal intensive care unit admission. The prognostic ability of CBB for phototherapy and TSB > 75th percentile was assessed using area under the receiver operating characteristic (ROC) curve. Logistic regression analyses were performed to determine predictors for phototherapy and TSB > 75th percentile. Result When compared to controls (n=142), cases (n=54) were more likely to have a positive Coombs’ test (82% vs. 41%, p 75th percentile (85% vs. 21%, p75th percentile was 0.87±0.03 (phemolytic disease of the newborn. PMID:26518407

  3. Predictive value of cord blood bilirubin for hyperbilirubinemia in neonates at risk for maternal-fetal blood group incompatibility and hemolytic disease of the newborn.

    Science.gov (United States)

    Calkins, K; Roy, D; Molchan, L; Bradley, L; Grogan, T; Elashoff, D; Walker, V

    2015-01-01

    To determine the predictive ability of cord blood bilirubin (CBB) for hyperbilirubinemia in a population at risk for maternal-fetal blood group incompatibility and hemolytic disease of the newborn. This is a single center retrospective case-control study. Cases received phototherapy; controls did not. Cases were matched 1:3 to controls by gender and treating physician. Inclusion criteria included: ≥35 weeks gestation, CBB, and one or more total serum bilirubin (TSB) concentrations. The primary outcome was CBB. Secondary outcomes were a TSB >75th percentile, length of stay, and neonatal intensive care unit admission. The prognostic ability of CBB for phototherapy and TSB >75th percentile was assessed using area under the receiver operating characteristic (ROC) curve. Logistic regression analyses were performed to determine predictors for phototherapy and TSB >75th percentile. When compared to controls (n = 142), cases (n = 54) were more likely to have a positive Coombs' test (82% vs. 41% , p 75th percentile (85% vs. 21% , p 75th percentile was 0.87 ± 0.03 (p hemolytic disease of the newborn.

  4. Maternal Fetal Attachment, Locus of Control and Adherence to STI/HIV Prevention and Prenatal Care Promotion Behaviors in Urban Women.

    Science.gov (United States)

    Kornfield, Sara L; Geller, Pamela A; Epperson, C Neill

    Young women of childbearing age are disproportionately affected by sexually transmitted infections (STIs) including HIV. In particular, young women have more frequent and more serious health problems from STI or HIV infection than men, and among women, African American women have especially high rates of infection. Pregnancy is an important time for beginning or continued STI and HIV prevention behaviors as discontinuing condom use when the contraceptive motivation is gone puts women and their fetuses at risk for contraction of STIs and HIV if they remain sexually active. There are many personal attributes that predict adherence to STI risk reduction behaviors including health related locus of control. The current study surveyed a group of 100 low-income, urban dwelling minority women during their pregnancies to determine whether maternal-fetal attachment, a characteristic specific to pregnancy, favorably influences pregnant women's health related locus of control such that women might be more inclined to engage in preventative STI/HIV risk reduction behaviors. Our findings revealed that while our sample has very high levels of MFA despite the high rate of unplanned pregnancy, condom use is not the method used to reduce the risk of contracting STIs/HIV. Rather, women are more likely to limit their number of sexual partners during pregnancy. While this is beneficial, pregnant women in non-monogamous relationships may discount the importance of condom use during pregnancy. Prenatal care providers can provide education about condom use as a beneficial prenatal care behavior similar to taking prenatal vitamins.

  5. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  6. GTA Beamloss-Monitor System

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper

  7. GTA beamloss-monitor system

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamloss-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamloss-Monitor System measures the induced gamma radiation, from (p,γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals, integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamloss-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics, is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/93 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper. (Author) 4 figs., ref

  8. Drinking-water monitoring systems

    International Nuclear Information System (INIS)

    1994-01-01

    A new measuring system was developed by the Austrian Research Centre Seibersdorf for monitoring the quality of drinking-water. It is based on the experience made with the installation of UWEDAT (registered trademark) environmental monitoring networks in several Austrian provinces and regions. The standard version of the drinking-water monitoring system comprises sensors for measuring chemical parameters in water, radioactivity in water and air, and meteorological values of the environment. Further measuring gauges, e.g. for air pollutants, can be connected at any time, according to customers' requirements. For integration into regional and supraregional networks, station computers take over the following tasks: Collection of data and status signals transmitted by the subsystem, object protection, intermediate storage and communication of data to the host or several subcentres via Datex-P postal service, permanent lines or radiotransmission

  9. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  10. Thermoluminescence dosimetry environmental monitoring system

    International Nuclear Information System (INIS)

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  11. Visualization System for Monitoring Data Management Systems

    Directory of Open Access Journals (Sweden)

    Emanuel Pinho

    2016-11-01

    Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.

  12. Energy Monitoring System Berbasis Web

    Directory of Open Access Journals (Sweden)

    Novan Zulkarnain

    2013-12-01

    Full Text Available Government through the Ministry of Energy and Mineral Resources (ESDM encourages the energy savings at whole buildings in Indonesia. Energy Monitoring System (EMS is a web-based solution to monitor energy usage in a building. The research methods used are the analysis, prototype design and testing. EMSconsists of hardware which consists of electrical sensors, temperature-humidity sensor, and a computer. Data on EMS are designed using Modbus protocol, stored in MySQL database application, and displayed on charts through Dashboard on LED TV using PHP programming.

  13. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  14. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  15. Type 2 porcine reproductive and respiratory syndrome virus infection increases apoptosis at the maternal-fetal interface in late gestation pregnant gilts.

    Directory of Open Access Journals (Sweden)

    Predrag Novakovic

    Full Text Available The pathogenesis of fetal death associated with porcine reproductive and respiratory syndrome (PRRS is hypothesized to be a consequence of PRRS virus-induced apoptosis at the maternal-fetal interface (MFI. The objectives of this study were to evaluate distribution and degree of apoptosis in the uterine and fetal placental tissues during the experimental type 2 PRRS virus (PRRSV infection and determine associations between apoptosis at the MFI, PRRSV RNA concentration and antigen staining intensity, PRRSV-induced microscopic lesions, and fetal preservation status. A total of 114 naïve, high-health pregnant gilts were inoculated with type 2 PRRSV on gestation day 85±1 with euthanasia 21 days later; 19 sham-inoculated gilts served as controls. Two hundred and fifty samples of uterine tissue with fetal placenta were selected based on negative, low PRRSV RNA, and high PRRSV RNA concentration (0, 2.7 log10 copies/mg, respectively. TUNEL assay was used to detect apoptosis in the endometrium and at the MFI. PRRSV RNA concentration and numbers of PRRSV immunopositive cells in uterine and placental tissue were positively associated with the severity of apoptosis in the endometrium and the MFI (P<0.001, P<0.05 and P<0.001, respectively. The number of TUNEL positive cells at the MFI was also positively associated with the severity (P<0.001 of vasculitis, but not total numbers of inflammatory cells in the endometrium. Increased numbers of TUNEL positive cells at the MFI were associated with PRRSV load in the fetal thymus, and greater odds of meconium staining of the fetus at 21 days post infection (P<0.001 for both. These findings suggest an important role of apoptosis in the pathogenesis of uterine epithelial and trophoblastic cell death at the MFI. Moreover, apoptosis at the MFI is significantly associated with fetal demise during in utero type 2 PRRSV infection.

  16. Selected maternal, fetal and placental trace element and heavy metal and maternal vitamin levels in preterm deliveries with or without preterm premature rupture of membranes.

    Science.gov (United States)

    Kucukaydin, Zehra; Kurdoglu, Mertihan; Kurdoglu, Zehra; Demir, Halit; Yoruk, Ibrahim H

    2018-01-25

    To compare maternal, fetal and placental trace element (magnesium, zinc and copper) and heavy metal (cadmium and lead) and maternal vitamin (retinol, α [alpha]-tocopherol, vitamin D 3 , 25-hydroxyvitamin D 3 and 1,25-dihydroxyvitamin D 3 ) levels in preterm deliveries with and without preterm premature rupture of membranes (PPROM). Sixty-eight patients giving birth preterm were grouped into preterm deliveries with PPROM (n = 35) and without PPROM (n = 33). Following delivery, maternal and umbilical cord blood sera and placental tissue samples were obtained. While magnesium, zinc, copper, cadmium and lead levels were measured in all samples, the levels of retinol, α-tocopherol, vitamin D 3 , 25-hydroxyvitamin D 3 and 1,25-dihydroxyvitamin D 3 were measured only in maternal serum. While magnesium level in maternal serum and zinc levels in both maternal and umbilical cord sera were lower, placental magnesium level was higher in preterm deliveries with PPROM (P 0.05). In preterm deliveries with PPROM, 25-hydroxyvitamin D 3 and retinol levels were higher, while vitamin D 3 and 1,25-dihydroxyvitamin D 3 levels were lower in maternal serum (P < 0.05). Maternal serum α-tocopherol levels were similar between the groups. Compared to spontaneous preterm births, PPROM is associated with low maternal serum together with high placental tissue magnesium and low maternal and umbilical cord sera zinc levels. Higher retinol and 25-hydroxyvitamin D 3 and lower vitamin D 3 and 1,25-dihydroxyvitamin D 3 maternal serum levels are also evident in these patients. © 2018 Japan Society of Obstetrics and Gynecology.

  17. Corral Monitoring System assessment results

    International Nuclear Information System (INIS)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system

  18. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  19. Operations Monitoring Assistant System Design

    Science.gov (United States)

    1986-07-01

    Logic. Artificial Inteligence 25(1)::75-94. January.18. 41 -Nils J. Nilsson. Problem-Solving Methods In Artificli Intelligence. .klcG raw-Hill B3ook...operations monitoring assistant (OMA) system is designed that combines operations research, artificial intelligence, and human reasoning techniques and...KnowledgeCraft (from Carnegie Group), and 5.1 (from Teknowledze). These tools incorporate the best methods of applied artificial intelligence, and

  20. Monitoring system for thermal plasma

    International Nuclear Information System (INIS)

    Romero G, M.; Vilchis P, A.E.

    1999-01-01

    In the Thermal plasma applications laboratory it has been the degradation project of oils for isolation in transformers. These are a very hazardous residues and at this time in the country they are stored in metal barrels. It has been the intention to undergo the oils to plasma for degradate them to non-hazardous residues. The system behavior must be monitored to establish the thermal plasma behavior. (Author)

  1. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    Science.gov (United States)

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  2. Energy Doubler cryoloop temperature monitor system

    International Nuclear Information System (INIS)

    Pucci, G.; Howard, D.

    1981-10-01

    The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control

  3. PC based vibration monitoring system

    International Nuclear Information System (INIS)

    Jain, Sanjay K.; Roy, D.A.; Pithawa, C.K.; Patil, R.K.

    2004-01-01

    Health of large rotating machinery gets reflected in the vibration signature of the rotor and supporting structures and proper recording of these signals and their analysis can give a clear picture of the health of the machine. Using these data and their trending, it is possible to predict an impending trouble in the machine so that preventive action can be taken in time and catastrophic failure can be avoided. Continuous monitoring and analysis can give quick warning and enable operator to take preventive measures. Reactor Control Division, BARC is developing a PC based Vibration monitoring system for turbo generator machinery. The System can acquire 20 vibration signals at a rate of 5000 samples per second and also 15 process signals at a rate of 100 samples/ sec. The software for vibration monitoring system includes acquisition modules, analysis modules and Graphical User Interface module. The acquisition module involves initialization, setting of required parameters and acquiring the data from PC-based data acquisition cards. The acquired raw vibration data is then stored for analysis using various software packages. The display and analysis of acquired data is done in LabVIEW 7.0 where the data is displayed in time as well as frequency domain along with the RMS value of the signal. (author)

  4. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  5. Distributed hierarchical radiation monitoring system

    International Nuclear Information System (INIS)

    Barak, D.

    1985-01-01

    A solution to the problem of monitoring the radiation levels in and around a nuclear facility is presented in this paper. This is a private case of a large scale general purpose data acqisition system with high reliability, availability and short maintenance time. The physical layout of the detectors in the plant, and the strict control demands dictated a distributed and hierarchical system. The system is comprised of three levels, each level contains modules. Level one contains the Control modules which collects data from groups of detectors and executes emergency local control tasks. In level two are the Group controllers which concentrate data from the Control modules, and enable local display and communication. The system computer is in level three, enabling the plant operator to receive information from the detectors and execute control tasks. The described system was built and is operating successfully for about two years. (author)

  6. Coolant monitoring systems for PWR reactors

    International Nuclear Information System (INIS)

    Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.

    1987-01-01

    The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated

  7. Relações entre a saúde mental da gestante e o apego materno-fetal Relations between pregnant women's mental health and maternal-fetal attachment

    Directory of Open Access Journals (Sweden)

    Patrícia Alvarenga

    2012-12-01

    Full Text Available O estudo investigou as relações entre variáveis sociodemográficas, saúde mental da gestante e o apego materno-fetal no terceiro trimestre de gestação. Participaram do estudo 261 gestantes selecionadas através de amostragem por acessibilidade em quatro maternidades públicas. As gestantes responderam individualmente uma ficha de dados sociodemográficos, a Escala de Apego Materno-Fetal e o SRQ-20. A análise de regressão revelou que o número de filhos (4% e a saúde mental materna (4,2% explicaram parte da variância no apego materno-fetal. A escolaridade da mãe e do pai não esteve associada a essa variável. O modelo de regressão múltipla considerando os quatro fatores analisados, explicou 8,2% da variância nos escores de apego materno-fetal. Discutem-se as implicações dessas variáveis na formação do vínculo da mãe com o bebê durante a gestação.This study investigated the relations among sociodemographic variables, pregnant women mental health, and maternal-fetal attachment in the third trimester of pregnancy. Participants were 261 pregnant women recruited from public maternity wards using a convenience sampling technique. Each pregnant woman completed a sociodemographic data form, the Maternal-Fetal Attachment Scale, and the SRQ-20. Regression analysis revealed that the number of children (4% and mothers' mental health (4.2% accounted for part of the variance in maternal-fetal attachment scores. Father's and mother's schooling was not associated with this variable. Taking the four analyzed factors into account, a multiple regression model accounted for 8.2% of the variance in the maternal-fetal attachment scores. The implications of these variables for mother-infant bonding during pregnancy are discussed.

  8. Battery Monitoring and Charging System

    National Research Council Canada - National Science Library

    Thivierge, Daniel P

    2007-01-01

    A battery monitoring device for a battery having cells grouped in modules. The device includes a monitoring circuit for each module which monitors the voltage in each cell and the overall module voltage...

  9. Monitoring Systems for Hydropower Plants

    Directory of Open Access Journals (Sweden)

    Damaschin Pepa

    2015-07-01

    Full Text Available One of the most important issue in hydro power industry is to determine the necessary degree of automation in order to improve the operation security. Depending upon the complexity of the system (the power plant equipment the automation specialist will build a philosophy of control following some general principals of security and operation. Helped by the modern digital equipment, today is relative easy to design a complete monitoring and supervising system including all the subparts of a hydro aggregate. A series of sensors and transducers specific for each auxiliary installation of the turbine and generator will be provided, together with a PLC or an industrial PC that will run an application software for implementing the security and control algorithms. The purpose of this paper is to offer a general view of these issues, providing a view of designing an automation & control and security system for hydro power plants of small, medium and big power.

  10. Radiation monitoring system for astronauts

    International Nuclear Information System (INIS)

    Thomson, I.; MacKay, G.; Ng, A.; Tomi, L.

    1996-01-01

    Astronauts in space are constantly under the bombardment of radiation particles from trapped electrons, and trapped proton. In addition, cosmic rays, while penetrating the spacecraft shell, generate secondary radiation of neutrons. As astronauts' stay in space is getting longer, the need for a real-time radiation monitoring device has become critical. Thermoluminescent dosemeter (TLD), used onboard both the MIR and the Space Transportation System (STS), cannot provide real-time dose reading. This paper describes a real-time direct read-out device, currently under development, which can measure skin, eye, and Blood Forming Organ (BFO) doses separately. (author)

  11. An analysis of variations of indications and maternal-fetal prognosis for caesarean section in a tertiary hospital of Beijing: A population-based retrospective cohort study.

    Science.gov (United States)

    Liu, Yajun; Wang, Xin; Zou, Liying; Ruan, Yan; Zhang, Weiyuan

    2017-02-01

    2014. Caesarean delivery on maternal request (CDMR) cannot improve the maternal-fetal prognosis compared with the spontaneous vaginal delivery. With the releasing of China's 2 children policy, more CS will be implemented due to previous CS. There is a need for further research that evaluates interventions for increasing VBAC rates that target clinicians.

  12. HTRA3 expression in non-pregnant rhesus monkey ovary and endometrium, and at the maternal-fetal interface during early pregnancy

    Directory of Open Access Journals (Sweden)

    Findlay Jock K

    2008-06-01

    Full Text Available Abstract Background HTRA3 is a recently identified member of the mammalian serine protease family HTRA (high temperature requirement factor A. In both the rodent and the human HTRA3 is transcribed into two mRNA species (long and short through alternative splicing. We have previously shown that HTRA3 is expressed in the mature rat ovary and may be involved in folliculogenesis and luteinisation. HTRA3 is also upregulated during mouse and human placental development. The current study investigated whether HTRA3 is also localised in the primate ovary (rhesus monkey n = 7. In addition, we examined the non-pregnant rhesus monkey endometrium (n = 4 and maternal-fetal interface during early pregnancy (n = 5 to further investigate expression of HTRA3 in primate endometrium and placentation. Methods HTRA3 mRNA levels in several rhesus monkey tissues was determined by semiquantitative RT-PCR. Protein expression and localisation of HTRA3 was determined by immunohistochemistry. Results Long and short forms of HTRA3 mRNA were detected in the ovary, aorta, bladder, small intestine, skeletal muscle, heart and uterus but not the liver nor the kidney. HTRA3 protein was immunolocalised to the oocyte of all follicular stages in the rhesus monkey ovary. Protein expression in mural and cumulus granulosa cells of late secondary follicles increased significantly compared to granulosa cells of primordial, primary and secondary follicles. Mural and cumulus granulosa cells of antral follicles also showed a significant increase in expression. Staining intensity was higher in the granulosa-lutein cells compared to the theca-lutein cells of corpora lutea (n = 3. In the non-pregnant monkey endometrium, HTRA3 was detected in the glandular epithelium. The basalis endometrial glands showed higher staining intensity than functionalis endometrial glands. During early pregnancy, strong staining for HTRA3 protein was seen in both maternal decidual cells and glands. Conclusion We

  13. A/H1N1 pandemic influenza vaccination: A retrospective evaluation of adverse maternal, fetal and neonatal outcomes in a cohort of pregnant women in Italy.

    Science.gov (United States)

    Fabiani, Massimo; Bella, Antonino; Rota, Maria C; Clagnan, Elena; Gallo, Tolinda; D'Amato, Maurizio; Pezzotti, Patrizio; Ferrara, Lorenza; Demicheli, Vittorio; Martinelli, Domenico; Prato, Rosa; Rizzo, Caterina

    2015-05-05

    Although concerns about safety of influenza vaccination during pregnancy have been raised in the past, vaccination of pregnant women was recommended in many countries during the 2009 A/H1N1 pandemic influenza. A retrospective cohort study was conducted to evaluate the risk of adverse maternal, fetal and neonatal outcomes among pregnant women vaccinated with a MF59-adjuvanted A/H1N1 pandemic influenza vaccine. The study was carried out in four Italian regions (Piemonte, Friuli-Venezia-Giulia, Lazio, and Puglia) among 102,077 pregnant women potentially exposed during the second or third trimester of gestation to the vaccination campaign implemented in 2009/2010. Based on data retrieved from the regional administrative databases, the statistical analysis was performed using the Cox proportional-hazards model, adjusting for the propensity score to account for the potential confounding effect due to the socio-demographic characteristics and the clinical and reproductive history of women. A total of 100,332 pregnant women were eligible for the analysis. Of these, 2003 (2.0%) received the A/H1N1 pandemic influenza vaccination during the second or third trimester of gestation. We did not observe any statistically significant association between the A/H1N1 pandemic influenza vaccination and different maternal outcomes (hospital admissions for influenza, pneumonia, hypertension, eclampsia, diabetes, thyroid disease, and anaemia), fetal outcomes (fetal death after the 22nd gestational week) and neonatal outcomes (pre-term birth, low birth weight, low 5-min Apgar score, and congenital malformations). Pre-existing health-risk conditions (hospital admissions and drug prescriptions for specific diseases before the onset of pregnancy) were observed more frequently among vaccinated women, thus suggesting that concomitant chronic conditions increased vaccination uptake. The results of this study add some evidence on the safety of A/H1N1 pandemic influenza vaccination during

  14. Quantitative and histological assessment of maternal-fetal transmission of Trypanosoma cruzi in guinea pigs: An experimental model of congenital Chagas disease.

    Directory of Open Access Journals (Sweden)

    Jatziri Torres-Vargas

    2018-01-01

    Full Text Available We evaluated the effect of Trypanosoma cruzi infection on fertility, gestation outcome, and maternal-fetal transmission in guinea pigs (Cavia porcellus.Animals were infected with T. cruzi H4 strain (TcI lineage before gestation (IBG or during gestation (IDG. Tissue and sera samples of dams and fetuses were obtained near parturition.All IBG and IDG dams were seropositive by two tests, and exhibited blood parasite load of 1.62±2.2 and 50.1±62 parasites/μl, respectively, by quantitative PCR. Histological evaluation showed muscle fiber degeneration and cellular necrosis in all infected dams. Parasite nests were not detected in infected dams by histology. However, qPCR analysis detected parasites-eq/g heart tissue of 153±104.7 and 169.3±129.4 in IBG and IDG dams, respectively. All fetuses of infected dams were positive for anti-parasite IgG antibodies and tissue parasites by qPCR, but presented a low level of tissue inflammatory infiltrate. Fetuses of IDG (vs. IBG dams exhibited higher degree of muscle fiber degeneration and cellular necrosis in the heart and skeletal tissues. The placental tissue exhibited no inflammatory lesions and amastigote nests, yet parasites-eq/g of 381.2±34.3 and 79.2±84.9 were detected in IDG and IBG placentas, respectively. Fetal development was compromised, and evidenced by a decline in weight, crow-rump length, and abdominal width in both groups.T. cruzi TcI has a high capacity of congenital transmission even when it was inoculated at a very low dose before or during gestation. Tissue lesions, parasite load, and fetal under development provide evidence for high virulence of the parasite during pregnancy. Despite finding of high parasite burden by qPCR, placentas were protected from cellular damage. Our studies offer an experimental model to study the efficacy of vaccines and drugs against congenital transmission of T. cruzi. These results also call for T. cruzi screening in pregnant women and adequate follow up of

  15. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  16. Monitoring of Danish marketed solar heating systems

    International Nuclear Information System (INIS)

    Ellehauge, K.

    1993-01-01

    The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)

  17. A real time monitoring system

    International Nuclear Information System (INIS)

    Fontanini, Horacio; Galdoz, Erwin

    1989-01-01

    A real time monitoring system is described. It was initially developed to be used as a man-machine interface between a basic principles simulator of the Embalse Nuclear Power Plant and the operators. This simulator is under construction at the Bariloche Atomic Center's Process Control Division. Due to great design flexibility, this system can also be used in real plants. The system is designed to be run on a PC XT or AT personal computer with high resolution graphics capabilities. Three interrelated programs compose the system: 1) Graphics Editor, to build static image to be used as a reference frame where to show dynamically updated data. 2) Data acquisition and storage module. It is a memory resident module to acquire and store data in background. Data can be acquired and stored without interference with the operating system, via serial port or through analog-to-digital converter attached to the personal computer. 3) Display module. It shows the acquired data according to commands received from configuration files prepared by the operator. (Author) [es

  18. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  19. Plant operation state monitoring system

    International Nuclear Information System (INIS)

    Sakai, Masanori; Babuchi, Katsumi; Arato, Toshiaki

    1994-01-01

    The system of the present invention accurately monitors a plant operation state of a plant, such as a nuclear power plant and a thermal power plant by using high temperature water, based on water quality informations. That is, water quality informations for the objective portion by using an electrochemical water quality sensor disposed in the objective portion to be monitored in the plant are continuously extracted for a predetermined period of time. Water quality is evaluated based on the extracted information. Obtained results for water quality evaluation and predetermined reference values of the plant operation handling are compared. Necessary part among the results of the measurement is displayed or recorded. The predetermined period of time described above is a period that the water quality information reaches at least a predetermined value or a period that the predetermined value is estimated by the water quality information, and it is defined as a period capable of measuring the information for three months continuously. The measurement is preferably conducted continuously in a period up to each periodical inspection on about every one year. (I.S.)

  20. A unique radiation area monitoring system

    International Nuclear Information System (INIS)

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  1. Radiation monitor system for nuclear power plants

    International Nuclear Information System (INIS)

    Wu Bingzhe; Guo Shusheng

    1990-12-01

    The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants

  2. Stack Monitoring System At PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin

    2014-01-01

    This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)

  3. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  4. Project W-420 stack monitoring system upgrades

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420

  5. Acoustic emission leak monitoring system LMS-96

    International Nuclear Information System (INIS)

    Liska, J.; Cvrcek, M.; Mueller, L.

    1997-01-01

    On-line acoustic emission leak monitoring under industrial conditions of nuclear power plants is a problem with specific features setting specific demands on the leak monitoring system. The paper briefly reviews those problems (attenuation pattern of a real structure, acoustic background, alarm system, etc.) and the solution of some of them is discussed. Information is presented on the Acoustic Emission Leak Monitoring System LMS-96 by SKODA NUCLEAR MACHINERY and the system's function is briefly described. (author)

  6. Data monitoring system of technical diagnosis system for EAST

    International Nuclear Information System (INIS)

    Qian Jing; Weng Peide; Chen Zhuomin; Wu Yu; Xi Weibin; Luo Jiarong

    2010-01-01

    Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor.. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described. (authors)

  7. Environmental monitoring system with TLD

    International Nuclear Information System (INIS)

    Aguerre, L.; Carelli, J.; Gregori, B.

    2006-01-01

    Presently work the methodology used by the Laboratory of Thermoluminescent Dosimetry (TLD) of the Nuclear Regulatory Authority (RNA) to gauge it system of environmental monitoring in function of the media absorbed dose rate in free air and the environmental dose equivalent, H * (10), according to the recommendation ICRU Report 47 is described. It was studied the response of the environmental dosemeter (DA) in fields of photonic radiation of energies W60, Wl 10, W200 and 137 Cs. The irradiations were carried out following the recommendations of the standard ISO:4037. It was analyzed the response in the DA of the detectors LiF: Mg, Ti and CaF 2 : Dy for the different radiation qualities and the relative response at 137 Cs of both. The methodology used in the evaluation of the dose includes: the correction of the readings of both detectors by fading, gotten experimentally, the witness of transfers, the energy answer and the value of the zero. The dose is calculated applying the average pondered in uncertainty of the dose obtained for each type of detector. Its were analyzed and calculated the uncertainties that affect to the measurement following the recommendation of the Argentine standard IRAM 35050. The detection limit of the absorbed dose rate in free air of this system it is 3.5 n Gy/h for a period of sampling of 3 months. With this detection limit environmental dose equivalent rates of the order of 70 n Sv/h are measured with an expanded uncertainty of the order of 10% with a cover factor k = 2. (Author)

  8. A prospective population-based study of maternal, fetal, and neonatal outcomes in the setting of prolonged labor, obstructed labor and failure to progress in low- and middle-income countries.

    Science.gov (United States)

    Harrison, Margo S; Ali, Sumera; Pasha, Omrana; Saleem, Sarah; Althabe, Fernando; Berrueta, Mabel; Mazzoni, Agustina; Chomba, Elwyn; Carlo, Waldemar A; Garces, Ana; Krebs, Nancy F; Hambidge, K; Goudar, Shivaprasad S; Dhaded, S M; Kodkany, Bhala; Derman, Richard J; Patel, Archana; Hibberd, Patricia L; Esamai, Fabian; Liechty, Edward A; Moore, Janet L; Koso-Thomas, Marion; McClure, Elizabeth M; Goldenberg, Robert L

    2015-01-01

    This population-based study sought to quantify maternal, fetal, and neonatal morbidity and mortality in low- and middle-income countries associated with obstructed labor, prolonged labor and failure to progress (OL/PL/FTP). A prospective, population-based observational study of pregnancy outcomes was performed at seven sites in Argentina, Guatemala, India (2 sites, Belgaum and Nagpur), Kenya, Pakistan and Zambia. Women were enrolled in pregnancy and delivery and 6-week follow-up obtained to evaluate rates of OL/PL/FTP and outcomes resulting from OL/PL/FTP, including: maternal and delivery characteristics, maternal and neonatal morbidity and mortality and stillbirth. Between 2010 and 2013, 266,723 of 267,270 records (99.8%) included data on OL/PL/FTP with an overall rate of 110.4/1000 deliveries that ranged from 41.6 in Zambia to 200.1 in Pakistan. OL/PL/FTP was more common in women aged 3500g, and women with a BMI >25 (RR 1.4, 95% CI 1.3 - 1.5), with the suggestion of OL/PL/FTP being less common in preterm deliveries. Protective characteristics included parity of ≥3, having an infant birth vaginally were more likely to become infected, to have an infected neonate, to hemorrhage in the antepartum and postpartum period, and to die, have a stillbirth, or have a neonatal demise. Women with OL/PL/FTP were far more likely to deliver in a facility and be attended by a physician or other skilled provider than women without this diagnosis. Women with OL/PL/FTP in the communities studied were more likely to be primiparous, younger than age 20, overweight, and of higher education, with an infant with birthweight of >3500g. Women with this diagnosis were more likely to experience a maternal, fetal, or neonatal death, antepartum and postpartum hemorrhage, and maternal and neonatal infection. They were also more likely to deliver in a facility with a skilled provider. CS may decrease the risk of poor outcomes (as in the case of antepartum hemorrhage), but unassisted vaginal

  9. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  10. Distributed Monitoring System Based on ICINGA

    CERN Multimedia

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  11. PEM fuel cell monitoring system

    Science.gov (United States)

    Meltser, Mark Alexander; Grot, Stephen Andreas

    1998-01-01

    Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

  12. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo

    1993-03-01

    Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)

  13. Critical function monitoring system algorithm development

    International Nuclear Information System (INIS)

    Harmon, D.L.

    1984-01-01

    Accurate critical function status information is a key to operator decision-making during events threatening nuclear power plant safety. The Critical Function Monitoring System provides continuous critical function status monitoring by use of algorithms which mathematically represent the processes by which an operating staff would determine critical function status. This paper discusses in detail the systematic design methodology employed to develop adequate Critical Function Monitoring System algorithms

  14. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  15. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  16. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  17. The design of radiation monitor passageway system

    International Nuclear Information System (INIS)

    Chu Chengsheng

    2006-10-01

    The Radiation Monitor Passageway System is designed as four modules, the radiation detection modules, the control modules, the mechanism modules and the optional modules. this system integrate the radiation detection technology and door ban control technology. It is a effective radiation monitor equipment with high detect sensitiveness, it will be hopeful devoted to national nuclear safeguard. (authors)

  18. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, H.; Kobalyashi, H.

    1993-01-01

    JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles

  19. Storage monitoring systems for the year 2000

    International Nuclear Information System (INIS)

    Nilsen, C.; Pollock, R.

    1997-01-01

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000

  20. Supervisory monitoring system in nuclear power plants

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Turkcan, E.

    1997-01-01

    Monitoring of a power plant is one of the essential tasks during operation and the computer-based implementations are nowadays seemingly quite mature. However, presently these are still not satisfactory enough to meet the high standards to the licensing requirements and they are mostly not truly integrated to the plant's design-based monitoring system. This is basically due to the robustness problem as the majority of the methods are not robust enough for the monitoring of the safety parameter set in a plant or intelligent supervision. Therefore, a supervisory monitoring system (SMS) in a plant is necessary to supervise the monitoring tasks: determining the objectives to be obtained and finding the means to support them. SMS deals with the changing plant status and the coordination of the information flow among the monitoring subunits. By means of these robustness and consistency in monitoring is achieved. The paper will give the guidelines of knowledge and data management techniques in a framework of robust comprehensive and coordinated monitoring which is presented as supervisory monitoring. Such a high level monitoring serves for consistent and immediate actions in fault situations while this particularly has vital importance in preventing imminent severe accidents next to the issues of recognition of the monitoring procedures for licensing and enhanced plant safety. (author). 8 refs, 5 figs

  1. The CERN GSM monitoring system

    International Nuclear Information System (INIS)

    Ghabrous, Carlos

    2010-01-01

    This paper presents the way CERN has approached the problem of monitoring its own GSM infrastructure, especially in the Large Hadron Collider (LHC) accelerator tunnel and other underground facilities, where a leaky feeder cable carries mobile phone signals, and where this technology is the only means for inter-personnel communications.

  2. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  3. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  4. Monitoring system in reactor dry well

    International Nuclear Information System (INIS)

    Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.

    1991-01-01

    A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)

  5. Intervalos de referência longitudinais de parâmetros doplervelocimétricos materno-fetais Longitudinal reference intervals of maternal-fetal Doppler parameters

    Directory of Open Access Journals (Sweden)

    Nelsilene Mota Carvalho Tavares

    2013-01-01

    scanned fortnightly from 18 to 40 weeks for the measurements of PI of the UA, MCA, DV and UtA. Linear mixed models were used for the elaboration of longitudinal reference intervals (5th, 50th and 95th percentiles of these measurements. PI obtained for the placental and abdominal portions of the umbilical artery were compared by the t-test for independent samples. Two-sided p values of less than 0.05 were considered statistically significant. RESULTS: A total of 164 patients underwent 1,242 scans. There was significant decrease in PI values of all vessels studied with gestational age (GA. From the 18th to the 40th week of pregnancy, the median PI values of UA (abdominal and placental ends of the cord, MCA, DV and the mean PI of the UtA ranged from 1.19 to 0.74, 1.33 to 0.78, 1.56 to 1.39, 0.58 to 0.41, and 0.98 to 0.66, respectively. The following equations were obtained for the prediction of the medians: PI-UA=1.5602786 - (0.020623 x GA; Logarithm of the PI-MCA=0.8149111 - (0.004168 x GA - [0.02543 x (GA - 28.7756²]; Logarithm of the PI-DV=-0.26691- (0.015414 x GA; PI-UtA = 1.2362403 - (0.014392 x GA. There was a significant difference between the PI-UA obtained at the abdominal and placental ends of the umbilical cord (p<0.001. CONCLUSIONS: Longitudinal reference intervals for the main gestational Doppler parameters were obtained in a Brazilian cohort. These intervals could be more adequate for the follow-up of maternal-fetal hemodynamic modifications in normal and abnormal pregnancies, a fact that still requires further validation.

  6. The VICKSI monitor interlock system

    International Nuclear Information System (INIS)

    Borchardt, D.; Kluppak, B.

    1983-01-01

    Dose rate equivalents are monitored separately for all working areas and evaluated by a central unit. The accelerator is shut off automatically if the maximum permissible concentrations given in the Radiation Protection Ordinance are exceeded and if persons are endangered. However, the experimenter may, on his own responsibility, define certain areas as 'vacated' (no staff members inside). Operation can then proceed as desired. Entry of persons into these areas is checked by the central computer. (orig./HP) [de

  7. EDGAR, a new plant radiation monitoring system

    International Nuclear Information System (INIS)

    Vuong, Q.M.; Da Costa Vieira, D.

    2004-01-01

    The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)

  8. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  9. Distributed intelligent urban environment monitoring system

    Science.gov (United States)

    Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang

    2018-02-01

    The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion

  10. Computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  11. Ulysses spacecraft control and monitoring system

    Science.gov (United States)

    Hamer, P. A.; Snowden, P. J.

    1991-01-01

    The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.

  12. RFID and IOT for Attendance Monitoring System

    Directory of Open Access Journals (Sweden)

    Dedy Irawan Joseph

    2018-01-01

    Full Text Available In recent years, RFID technology has been widely used in various sectors, such as in-education, transportation, agriculture, animal husbandry, store sales and other sectors. RFID utilization in education is student attendance monitoring system, by using Internet of Things (IoT and Cloud technology, it will produce a real time attendance monitoring system that can be accessed by various parties, such as lecturer, campus administration and parents. With this monitoring system if there are students who are not present can be immediately discovered and can be taken immediate action and the learning process can run smoothly.

  13. Remote supervision of GIS monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pannunzio, J.; Juge, P.; Ficheux, A.; Rayon, J.L. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada)

    2007-07-01

    Operators of gas-insulated substations (GIS) are increasingly concerned with failure prevention, scheduled maintenance, personnel safety and shortage of maintenance crews. Until recently, the density levels of the insulating gas sulfur hexafluoride (SF6) was the only parameter controlled in gas-insulated substations. Modern digital type control and monitoring equipment have been widely used in the past decade. Remote indication of gas density and status of dynamic components was made possible and shown on local control panels. Modern GIS monitoring systems offer features such as SF6 monitoring, SF6 leakage trends, internal arc localization and detection. The required information is recorded in a local computer and displaced onto a local human machine interface (HMI) or a local industrial PC mounted next to the GIS. These monitoring systems are used as decision making tools to facilitate maintenance activities and optimize the management of assets. This paper presented the latest developments in digital monitoring systems in terms of modern digital architecture; management of information flows between monitoring systems and control systems; operation of remote supervision; configuration of high voltage substations and information sharing; and, types of links between GIS room and remote supervision. This paper also demonstrated what can be achieved by moving the central HMI of a GIS monitoring system to the decision-making centres. It was shown that integrated features that allow remote on-line or automated management have reached an acceptable level of reliability and comfort for operators. 5 figs.

  14. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  15. Automated Cryocooler Monitor and Control System Software

    Science.gov (United States)

    Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad

    2011-01-01

    This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

  16. Communications interface for plant monitoring system

    International Nuclear Information System (INIS)

    Lee, K.L.; Morgan, F.A.

    1988-01-01

    This paper presents the communications interface for an intelligent color graphic system which PSE and G developed as part of a plant monitoring system. The intelligent graphic system is designed to off-load traditional host functions such as dynamic graphic updates, keyboard handling and alarm display. The distributed system's data and synchronization problems and their solutions are discussed

  17. Activity monitoring systems in health care

    NARCIS (Netherlands)

    Kröse, B.; van Oosterhout, T.; van Kasteren, T.; Salah, A.A.; Gevers, T.

    2011-01-01

    This chapter focuses on activity monitoring in a home setting for health care purposes. First the most current sensing systems are described, which consist of wearable and ambient sensors. Then several approaches for the monitoring of simple actions are discussed, like falls or therapies. After

  18. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  19. EMBEDDED SYSTEMS FOR VIBRATION MONITORING

    Directory of Open Access Journals (Sweden)

    Miloš Milovančević

    2014-08-01

    Full Text Available The purpose of the research presented in this paper is the development of the optimal micro configuration for vibration monitoring of pumping aggregate, based on Microchip’s microcontroller (MC. Hardware used is 10-bit MC, upgraded with 12/bit A/D converter. Software for acquisition and data analysis is optimized for testing turbo pumps with rotation speed up to 2000 rpm. This software limitation is set for automatic diagnostics and for individual and manual vibro-diagnostic; the only limitation is set by accelerometer performance. The authors have performed numerous measurements on a wide range of turbo aggregates for establishing the operational condition of pumping aggregates.

  20. Wearable Health Monitoring Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  1. Radiation monitoring system based on EPICS

    International Nuclear Information System (INIS)

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)

  2. Deployable Thermoelectric Metamaterial Energy Harvesting Monitoring System

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will combine a novel asynchronous monitoring system with the first-of-its-kind thermoelectric metamaterial.  The thermoelectric prototype is constructed...

  3. Wearable Health Monitoring Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  4. Geographic information system planning and monitoring best ...

    African Journals Online (AJOL)

    Poor urbanization policies, inefficient planning and monitoring technologies are evident. The consequences include some of the worst types of environmental hazards. Best urbanization practices require integrated planning approaches that result in environmental conservation. Geographic Information systems (GIS) provide ...

  5. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  6. ZPR-9 airborne plutonium monitoring system

    International Nuclear Information System (INIS)

    Rusch, G.K.; McDowell, W.P.; Knapp, W.G.

    1975-01-01

    An airborne plutonium monitoring system which is installed in the ZPR-9 (Zero Power Reactor No. 9) facility at Argonne National Laboratory is described. The design and operational experience are discussed. This monitoring system utilizes particle size and density discrimination, alpha particle energy discrimination, and a background-subtraction techique operating in cascade to separate airborne-plutonium activity from other, naturally occurring, airborne activity. Relatively high sensitivity and reliability are achieved

  7. Data monitoring system for PV solar generators

    International Nuclear Information System (INIS)

    Stoev, M.; Katerski, A.; Williams, A.

    2000-01-01

    The two 1.5 kWp photovoltaic (PV) solar generators are installed and the new PC data monitoring system is developed by applying EC standards for European Solar Test Installation (ESTI). The schematic system diagram of PV generator is presented. The recording parameters for analytical and global monitoring are discussed. The meteorological data from ESTI sensors, temperature sensor and electrical data from inverter and calibrated shunt are stored via analog digital converters (ADC) on a hard disk of data storage PC. Data Logger and Monitor software for automatic data acquisition, treatment and visual distance control of all output PV data from PV solar generator has been created

  8. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  9. Moisture monitoring and control system engineering study

    International Nuclear Information System (INIS)

    Carpenter, K.E.; Fadeff, J.G.

    1995-01-01

    During the past 50 years, a wide variety of chemical compounds have been placed in the 149 single-shell tanks (SSTS) on the Hanford Site. A concern relating to chemical stability, chemical control, and safe storage of the waste is the potential for propagating reactions as a result of ferrocyanide-oxidizer and organic-oxidizer concentrations in the SSTS. Propagating reactions in fuel-nitrate mixtures are precluded if the amounts of fuel and moisture present in the waste are within specified limits. Because most credible ignition sources occur near the waste surface, the main emphasis of this study is toward monitoring and controlling moisture in the top 14 cm (5.5 in.) of waste. The purpose of this engineering study is to recommend a moisture monitoring and control system for use in SSTs containing sludge and saltcake. This study includes recommendations for: (1) monitoring and controlling moisture in SSTs; (2) the fundamental design criteria for a moisture monitoring and control system; and (3) criteria for the deployment of a moisture monitoring and control system in hanford Site SSTs. To support system recommendations, technical bases for selecting and using a moisture monitoring and control system are presented. Key functional requirements and a conceptual design are included to enhance system development and establish design criteria

  10. Monitor for reactor feedwater systems

    International Nuclear Information System (INIS)

    Takizawa, Yoji; Tomizawa, Teruaki

    1983-01-01

    Purpose: To improve the reliability of operator's procedures upon occurrence of the feedwater system abnormality in a BWR type reactor by presenting the operation with effective information to avoid such abnormality. Constitution: A feedwater temperature at the reactor inlet of a reactor feedwater system measured by a temperature detector and a predetermined value for the feedwater temperature at the reactor inlet determined depending on the reactor conditions are inputted to a start-up system. The start-up system outputs a start-up signal when the difference between the inputted values exceeds a predetermined value. Then, the start-up signal is inputted to a display device where information required for the operator is displayed in the device. Thus, the information required for the operator is rapidly provided upon abnormality of the feedwater system to thereby improve the reliability of the operator's procedures. (Moriyama, K.)

  11. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  12. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  13. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  14. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  15. Reliability of operating WWER monitoring systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.

    1996-01-01

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs

  16. Monitoring system for OpenPBS environment

    Energy Technology Data Exchange (ETDEWEB)

    Kolosov, V. [ITEP, Moscow (Russian Federation)]. E-mail: victor.kolosov@itep.ru; Lublev, Y. [ITEP, Moscow (Russian Federation); Makarychev, S. [ITEP, Moscow (Russian Federation)

    2004-11-21

    The OpenPBS batch system is widely used in the HEP community. The Open PBS package has a set of tools to check the current status of the system. This information is useful, but it is not sufficient enough for resource accounting and planning. As a solution for this problem, we developed a monitoring system which parses the logfiles from OpenPBS and stores the information into a SQL database (PostgreSQL). This allows us to analyze the data in many different ways using SQL queries. The system was used in ITEP during the last two years for batch farm monitoring.

  17. Remote monitoring system workshop and technical cooperation

    International Nuclear Information System (INIS)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W.

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person

  18. Reliability of operating WWER monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.

    1997-12-31

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.

  19. An environmental monitoring detection system

    International Nuclear Information System (INIS)

    Leli Yuniarsari; Istofa; Sukandar

    2015-01-01

    Is part of radiation detection of the nuclear facilities engineering activities within nuclear facilities. The system comprised of gamma-ray radiation detector and weather detection which includes anemometer to detect the wind direction and speed, as well as rain gauge to measure the rainfall in a period of time. Data acquisition of the output is processed by Arduino Uno system which transformed the data into a particular standard and then displayed online in the website. The radiation detection system uses gamma-ray detector of NaI(Tl) and GM which convert the radiation detected into electric pulse to be fed into a pre-amp and amplifier and modified into square pulse. The weather detection system on the other hand works based on switch principle. For example, the wind with a certain speed could turn on a switch in the system and produce a voltage or pulse which can be measured. This value will then be interpreted as the wind direction and speed. Likewise for the rainfall gauge, the volume of water entering the bucket will turn the switch on, at the same time producing 1 pulse. The result of the experiment shows that for radiation detection system the output is a square pulse 4 volts by using detector NaI(Tl) and 4.4 volts by using detector GM. For weather detection system, basically was able to detect the wind direction, wind speed and rainfall just to find out further research is needed accuracy and the results compared with the standard tools available in BMKG. (author)

  20. Tritium monitor and collection system

    Science.gov (United States)

    Bourne, G.L.; Meikrantz, D.H.; Ely, W.E.; Tuggle, D.G.; Grafwallner, E.G.; Wickham, K.L.; Maltrud, H.R.; Baker, J.D.

    1992-01-14

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter. 7 figs.

  1. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  2. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion......Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  3. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  4. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  5. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  6. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  7. Monitoring support system for nuclear power plant

    International Nuclear Information System (INIS)

    Higashikawa, Yuichi; Kubota, Rhuji; Tanaka, Keiji; Takano, Yoshiyuki

    1996-01-01

    The nuclear power plants in Japan reach to 49 plants and supply 41.19 million kW in their installed capacities, which is equal to about 31% of total electric power generation and has occupied an important situation as a stable energy supplying source. As an aim to keeping safe operation and working rate of the power plants, various monitoring support systems using computer technology, optical information technology and robot technology each advanced rapidly in recent year have been developed to apply to the actual plants for a plant state monitoring system of operators in normal operation. Furthermore, introduction of the emergent support system supposed on accidental formation of abnormal state of the power plants is also investigated. In this paper, as a monitoring system in the recent nuclear power plants, design of control panel of recent central control room, introduction to its actual plant and monitoring support system in development were described in viewpoints of improvement of human interface, upgrade of sensor and signal processing techniques, and promotion of information service technique. And, trend of research and development of portable miniature detector and emergent monitoring support system are also introduced in a viewpoint of labor saving and upgrade of the operating field. (G.K.)

  8. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  9. Well Monitoring System For EGS

    Energy Technology Data Exchange (ETDEWEB)

    Normann, Randy [Perma Works LLC, Pattonville, TX (United States); Glowka, Dave [Perma Works LLC, Pattonville, TX (United States); Normann, Charles [Perma Works LLC, Pattonville, TX (United States); Parker, James [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Josip [Electrochemical Systems Inc, Knoxville, TN (United States); Dustan, Don [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Mario [Electrochemical Systems Inc, Knoxville, TN (United States); Sariri, Kouros [Frequency Management Int. Inc., Huntington Beach, CA (United States); Beal, Craig [MajiQ Technologies Inc., Somerville, MA (United States)

    2017-02-26

    This grant is a collection of projects designed to move aircraft high temperature electronics technology into the geothermal industry. Randy Normann is the lead. He licensed the HT83SNL00 chip from Sandia National Labs. This chip enables aircraft developed electronics for work within a geothermal well logging tool. However, additional elements are needed to achieve commercially successful logging tools. These elements are offered by a strong list of industrial partners on this grant as: Electrochemical Systems Inc. for HT Rechargeable Batteries, Frequency Management Systems for 300C digital clock, Sandia National Labs for experts in high temperature solder, Honeywell Solid-State Electronics Center for reprogrammable high temperature memory. During the course of this project MagiQ Technologies for high temperature fiber optics.

  10. Amplified OTDR Systems for Multipoint Corrosion Monitoring

    Science.gov (United States)

    Nascimento, Jehan F.; Silva, Marcionilo J.; Coêlho, Isnaldo J. S.; Cipriano, Eliel; Martins-Filho, Joaquim F.

    2012-01-01

    We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR) technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations. PMID:22737017

  11. Hypoxia, Monitoring, and Mitigation System

    Science.gov (United States)

    2015-08-01

    art_psych_combat.htm “Humans have three primary survival systems: vision, cognitive processing, and motor skill performance. Under stress , all...fundamental truth of modern combat is that the stress of facing close-range interpersonal aggression is so great that, if endured for months on end without... Stroop Test. However these authors felt that improved cognitive function may be due to cerebral neural activation associated with exercise rather

  12. Radiation monitoring system in medical facilities

    International Nuclear Information System (INIS)

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  13. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Marjanovic, Marija; The ATLAS collaboration

    2018-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibers to photo-multiplier tubes (PMTs), located in the outer part of the calorimeter. The readout is segmented into about 5000 cells, each one being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of the full readout chain during the data taking, a set of calibration sub-systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements, and an integrator based readout system. Combined information from all systems allows to monitor and to equalize the calorimeter response at each stage of the signal evolution, from scintillation light to digitization. Calibration runs are monitored from a data quality perspective and u...

  14. An automated neutron monitor maintenance system

    International Nuclear Information System (INIS)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-01-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  15. Integrated environmental monitoring and information system

    International Nuclear Information System (INIS)

    Klinda, J.; Lieskovska, Z.

    1998-01-01

    The concept of the environmental monitoring within the territory of the Slovak Republic and the concept of the integrated environmental information system of the Slovak Republic were accepted and confirmed by the Government Order No. 449/1992. The state monitoring system covering the whole territory of Slovakia is the most important and consists of 13 Partial Monitoring Systems (PMSs). List of PMSs is included. The listed PMSs are managed according to the concept of the Sectoral Information System (SIS) of the Ministry of the Environment of the Slovak Republic (MESR) which was established by the National Council Act No. 261/1995 Coll. on the SIS. The SIS consists of 18 subsystems which are listed. The overviews of budget of PMSs as well as of environmental publications and periodicals of the MESR are included

  16. Pickering Nuclear site wide groundwater monitoring system

    International Nuclear Information System (INIS)

    DeWilde, J.; Chin-Cheong, D.; Lledo, C.; Wootton, R.; Belanger, D.; Hansen, K.

    2001-01-01

    Ontario Power Generation Inc. (OPG) is continuing its efforts to understand the chemical and physical characteristics of the groundwater flow systems beneath the Pickering Nuclear Generating Station (PNGS). To this end, OPG constructed a site-wide Groundwater Monitoring System (GMS) at the PNGS to provide support to other ongoing environmental investigations and to provide a means to monitor current and future groundwater environmental issues. This paper will present the results of this work, including the development of a state-of-the-art data management system for storage and retrieval of environmental data for the site, which has applications for other power generation facilities. (author)

  17. Modernization of WWER-1000 radiation monitoring systems

    International Nuclear Information System (INIS)

    Smith, T.

    1995-01-01

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs

  18. Modernization of WWER-1000 radiation monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T [General Atomics, San Diego, CA (United States)

    1996-12-31

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs.

  19. The AGS Booster Beam Position Monitor system

    International Nuclear Information System (INIS)

    Ciardullo, D.J.; Abola, A.; Beadle, E.R.; Smith, G.A.; Thomas, R.; Van Zwienen, W.; Warkentien, R.; Witkover, R.L.

    1991-01-01

    To accelerate both protons and heavy ions, the AGS Booster requires a broadband (multi-octave) beam position monitoring system with a dynamic range spanning several orders of magnitude (2 x 10 10 to 1.5 x 10 13 particles per pulse). System requirements include the ability to acquire single turn trajectory and average orbit information with ± 0.1 mm resolution. The design goal of ± 0.5 mm corrected accuracy requires that the detectors have repeatable linear performance after periodic bakeout at 300 degree C. The system design and capabilities of the Booster Beam Position Monitor will be described, and initial results presented. 7 refs., 5 figs

  20. Development of the simulation monitoring system

    International Nuclear Information System (INIS)

    Kato, Katsumi; Watanabe, Tadashi; Kume, Etsuo

    2001-01-01

    Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering for the computational science research in nuclear fields. Visualization and animation processing techniques are developed for efficient understanding of simulation results. The development of the simulation monitoring system, which is used for real-time visualization of ongoing simulations or for successive visualization of calculated results, is described in this report. The standard visualization tool AVS5 or AVS/EXPRESS is used for the simulation monitoring system, and thus, this system can be utilized in various computer environments. (author)

  1. Embedded data acquisition system for neutron monitors

    International Nuclear Information System (INIS)

    Población, Ó G; Tejedor, I G; Sánchez, S; Blanco, J J; Gómez-Herrero, R; Medina, J; Steigies, C T

    2014-01-01

    This article presents the design and implementation of a new data acquisition system to be used as replacement for the old ones that have been in use with neutron monitors for the last decades and, which are eventually becoming obsolete. This new system is also intended to be used in new installations, enabling these scientific instruments to use today's communication networks to send data and receive commands from the operators. This system is currently running in two stations: KIEL2, in the Christian-Albrechts-Universität zu Kiel, Kiel, Germany, and CALMA, in the Castilla-La Mancha Neutron Monitor, Guadalajara, Spain

  2. Standard monitoring system for domestic heat pumps

    NARCIS (Netherlands)

    Geelen, C.P.J.M.; Oostendorp, P.A.

    1999-01-01

    In the years to come many domestic heat pump systems are to be installed in the Netherlands. The Dutch agency for energy and environment, NOVEM, and the association of energy utility companies, EnergieNed, give high priority to the monitoring of heat pump systems. The results of the projects,

  3. Psychometric aspects of pupil monitoring systems

    NARCIS (Netherlands)

    Glas, Cornelis A.W.; Geerlings, Hanneke

    2009-01-01

    Pupil monitoring systems support the teacher in tailoring teaching to the individual level of a student and in comparing the progress and results of teaching with national standards. The systems are based on the availability of an item bank calibrated using item response theory. The assessment of

  4. A system for environmental monitoring

    International Nuclear Information System (INIS)

    Tawil, R.A.; Velbeck, K.J.; Rotunda, J.E.; Flory, C.; Moscovitch, M.

    1993-01-01

    The system described in this paper consists of a reader, multi-element dosemeters, and dose algorithm. The reader is a medium capacity non-contact gas heating unit interfaced to an application software package that evaluates and manages generated data. The dosemeter consists of elements that are 240 mg.cm -2 thick and which are symmetrically filtered. The two CaF 2 :Dy (TLD-200) elements are shielded by 80 mg.cm -2 ABS plastic, 0.25 mm tantalum and 0.05 mm lead. The two LiF:Mg,Ti (TLD-100) are shielded by the 80 mg.cm -2 ABS plastic only. The response of this system was characterised according to the criteria established in the ANSI Standard N545, Section 4, as modified by NRC Regulatory Guide 4.13. The procedures applied to study the energy response, fading, linearity, uniformity, minimum detectability, reproducibility, reponse dependence on angle of incidence are described, reviewed, and the results presented. The study also included self-irradiation, sensitivity to light and moisture, and performance in actual field conditions. The results demonstrate that this dosemeter satisfies all of the N545-1975 performance requirements. The dose calculation algorithm developed for this dosemeter is outlined and the accuracy of its performance in various pure and mixed fields has been determined. The results are presented and discussed. (author)

  5. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  6. Radiachromic: a radiation monitoring system

    International Nuclear Information System (INIS)

    Humpherys, K.C.; Kantz, A.D.

    1977-01-01

    Various plastic film materials have been utilized to measure radiation fields. The radiachromic materials have been found to have advantages in reproducibility, stability, equivalent response to electrons and gamma ray fields, dose rate dependence and negligible variation for most environmental parameters. A simple photometer has been developed for read-out. The physical and chemical properties of the total system are described. A standard radiachromic has been selected for application to radiation processing. This material has a dose range of 5 x 10 4 to 3 x 10 7 rads, no dose rate effects to above 4 x 10 14 R/sec, an equivalent response to electrons and gamma rays, shelf life of greater than one year. Other forms are also applicable to radiation processing. (author)

  7. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  8. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  9. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  10. Data-acquisition system for radon monitoring

    International Nuclear Information System (INIS)

    Franklin, J.C.; Zawadzki, R.J.; Meyer, T.O.; Hill, A.L.

    1976-01-01

    A data-acquisition system was designed by the Bureau of Mines to monitor five detectors with radon continuously flowing through each. These detectors could be monitored up to 12 times an hour, but were only monitored according to a preset time, thus allowing radon to be monitored continuously in a uranium mine. The counter can be set to monitor each detector for any period of time up to 16.5 minutes. This allows very low concentrations to be monitored longer to reduce statistical error. There would be no upper limit in radon concentration that could be monitored, but there would be a lower limit of 50 pCi/l. Each detector was calibrated by the Lucas flask method. Multiple samples were taken at two different concentrations, and the correction factor for each detector was determined by a least squares fit of the data. To verify the calibrations, a series of measurements at several concentrations were made against a constant source. The agreement at low radon concentrations (300 pCi/l) with the two-filter method was within 3 percent; thus, the total error would be this difference plus the two-filter error. At high concentrations, the coefficient of variation ranged between 2.1 and 9.8 percent for the five different detector units

  11. Design of BEPCII bunch current monitor system

    International Nuclear Information System (INIS)

    Zhang Lei; Ma Huizhou; Yue Junhui; Lei Ge; Cao Jianshe; Ma Li

    2008-01-01

    BEPC II is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPC II. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPC II timing system can also use the bunch current database to decide which bucket needs to refill to implement 'top-off' injection. (authors)

  12. Smart Sensor Network System For Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Javed Ali Baloch

    2012-07-01

    Full Text Available SSN (Smart Sensor Network systems could be used to monitor buildings with modern infrastructure, plant sites with chemical pollution, horticulture, natural habitat, wastewater management and modern transport system. To sense attributes of phenomena and make decisions on the basis of the sensed value is the primary goal of such systems. In this paper a Smart Spatially aware sensor system is presented. A smart system, which could continuously monitor the network to observe the functionality and trigger, alerts to the base station if a change in the system occurs and provide feedback periodically, on demand or even continuously depending on the nature of the application. The results of the simulation trials presented in this paper exhibit the performance of a Smart Spatially Aware Sensor Networks.

  13. Monitoring SLAC High Performance UNIX Computing Systems

    International Nuclear Information System (INIS)

    Lettsome, Annette K.

    2005-01-01

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface

  14. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  15. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  16. A dose monitoring system for dental radiography

    International Nuclear Information System (INIS)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young

    2016-01-01

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose

  17. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  18. Trend Monitoring System (TMS) graphics software

    Science.gov (United States)

    Brown, J. S.

    1979-01-01

    A prototype bus communications systems, which is being used to support the Trend Monitoring System (TMS) and to evaluate the bus concept is considered. A set of FORTRAN-callable graphics subroutines for the host MODCOMP comuter, and an approach to splitting graphics work between the host and the system's intelligent graphics terminals are described. The graphics software in the MODCOMP and the operating software package written for the graphics terminals are included.

  19. GSM BASED IRRIGATION CONTROL AND MONITORING SYSTEM

    OpenAIRE

    GODFREY A. MILLS; STEPHEN K. ARMOO; AGYEMAN K. ROCKSON; ROBERT A. SOWAH; MOSES A. ACQUAH

    2013-01-01

    Irrigated agriculture is one of the primary water consumers in most parts of the world. With developments in technology, efforts are being channeled into automation of irrigation systems to facilitate remote control of the irrigation system and optimize crop production and cost effectiveness. This paper describes an on-going work on GSM based irrigation monitoring and control systems. The objective of the work is to provide an approach that helps farmers to easily access, manage and regulate ...

  20. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to an equipment rack controller on the equipment rack. The equipment rack controllers link to a central control computer that provides an operator ...

  1. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  2. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  3. Design of Wind Turbine Vibration Monitoring System

    Directory of Open Access Journals (Sweden)

    Shoubin Wang

    2013-04-01

    Full Text Available In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed. In this paper, it analyses the enlargement of all the parts of the structure and the working mechanism, the research method of wind turbine operation vibration is introduced, with the focus being the use of the sensor principle. Finally the hardware design and software of this system is introduced and the main function of this system is described, which realizes condition monitoring of the work state of wind turbines.

  4. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....

  5. Hanger-type laundry monitor system

    International Nuclear Information System (INIS)

    Aoyama, Kei; Kouno, Yoshio; Yanagishima, Ryouhei; Ikeda, Yasuyuki; Nakatani, Masahiro

    1987-01-01

    Laundry monitor is installed in nuclear power plants or other nuclear facilities in order to efficiently detect radioactive contamination remains on the surfaces of the working clothes which were used in the controlled area and washed afterward. The number of the working clothes which must be measured has been increasing in accordance with the increase of the nuclear facilities. This fact and recent intensified radiation control require automatic, high-speed and high sensitive measurement. Conveyer-type laundry monitor in which the working clothes are inserted by the metal net conveyer has been generally used, and recently new system with an automatic folder has become more popular. But, this type of system has not so big capacity because the clothes are conveyed longitudinally and also requires considerable wide space when installed. Fuji electric Co., Ltd. has been engaging in research and development for an optimum laundry monitor system used in nuclear facilities since the joint investigation with ten electric power companies in Japan in 1982. Consequently hanger-type laundry monitor system using automatic hanger conveyer was developed and 2 systems were delivered to Chubu Electric Power Co., Ltd. in 1986. This system permits to detect radioactive contamination on the working clothes, pick the contaminated clothes out and fold the uncontaminated clothes fully automatically and continuously. Moreover it allows to shorten the measurement time because the clothes are conveyed transversely and save the installation space, so that this will be regarded as considerably complete system in the world. This report describes the outline of the hanger-type laundry monitor system. (author)

  6. Evaluation of a multiport groundwater monitoring system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Hall, S.H.; Olsen, K.B.; Spane, F.A. Jr.

    1991-03-01

    In 1988 and 1989, Pacific Northwest Laboratory installed a multiport groundwater monitoring system in two wells on the Hanford Site: one near the 216-B-3 Pond in the center of the Hanford Site and one just north of the 300 Area near the Columbia River. The system was installed to provide the US Department of Energy with needed three-dimensional data on the vertical distribution of contaminants and hydraulic heads on the Hanford Site. This study evaluates the ability of the multiport system to obtain hydrogeologic data at multiple points vertically in a single borehole, and addresses the representativeness of the data. Data collected from the two wells indicate that the multiport system is well suited for groundwater monitoring networks requiring three-dimensional characterization of the hydrogeologic system. A network of these systems could provide valuable information on the hydrogeologic environment. However, the advantages of the multiport system diminish when the system is applied to long-term monitoring networks (30+ years) and to deeper wells (<300 ft). For shallow wells, the multiport system provides data in a cost-effective manner that would not be reasonably obtainable with the conventional methods currently in use at the Hanford Site. 17 refs., 28 figs., 6 tabs

  7. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  8. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  9. Background compensation methodologies for contamination monitoring systems

    International Nuclear Information System (INIS)

    Raman, Anand; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiation surveillance program in the various nuclear facilities incorporate contamination monitoring as an important component. Contamination monitoring programs constitute monitoring for alpha and beta contamination of the physical entities associated with the working personnel that include his hands, feet, clothing, shoes as well as the general surface areas in the working environment like floors. All these measurements are fraught with the contribution of the ambient gamma background radiation fields. These inhibit a proper and precise estimation of the contamination concentration being monitored. This paper investigates the efficacy of two methodologies that have been incorporated in two of the contamination monitoring systems developed in the Division. In the first system discussed, a high degree of gamma compensation has been achieved for an uniform exposure of the order of 50 nSv/hr to 100 mSv/hr. In the second system discussed, the degree of gamma compensation achieved is equal to those dictated by the statistical nature of the uncertainties associated with the subtraction of background from the source data. These two methods can be very effectively employed depending on the application requirement. A minimum detection level equivalent to 0.37 Bq/cdm 2 has been achieved in both these cases

  10. Uranium concentration monitor manual: 2300 system

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.

    1985-04-01

    This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs

  11. An interactive beam position monitor system simulator

    International Nuclear Information System (INIS)

    Ryan, W.A.; Shea, T.J.

    1993-03-01

    A system simulator has been implemented to aid the development of the RHIC position monitor system. Based on the LabVIEW software package by National Instruments, this simulator allows engineers and technicians to interactively explore the parameter space of a system during the design phase. Adjustable parameters are divided into three categories: beam, pickup, and electronics. The simulator uses these parameters in simple formulas to produce results in both time-domain and frequencydomain. During the prototyping phase, these simulated results can be compared to test data acquired with the same software package. The RHIC position monitor system is presented as an example, but the software is applicable to several other systems as well

  12. Radiation monitoring system based on Internet

    International Nuclear Information System (INIS)

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  13. Environmental radiation monitoring system with GPS (global positioning system)

    International Nuclear Information System (INIS)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  14. Wireless remote monitoring system for sleep apnea

    Science.gov (United States)

    Oh, Sechang; Kwon, Hyeokjun; Varadan, Vijay K.

    2011-04-01

    Sleep plays the important role of rejuvenating the body, especially the central nervous system. However, more than thirty million people suffer from sleep disorders and sleep deprivation. That can cause serious health consequences by increasing the risk of hypertension, diabetes, heart attack and so on. Apart from the physical health risk, sleep disorders can lead to social problems when sleep disorders are not diagnosed and treated. Currently, sleep disorders are diagnosed through sleep study in a sleep laboratory overnight. This involves large expenses in addition to the inconvenience of overnight hospitalization and disruption of daily life activities. Although some systems provide home based diagnosis, most of systems record the sleep data in a memory card, the patient has to face the inconvenience of sending the memory card to a doctor for diagnosis. To solve the problem, we propose a wireless sensor system for sleep apnea, which enables remote monitoring while the patient is at home. The system has 5 channels to measure ECG, Nasal airflow, body position, abdominal/chest efforts and oxygen saturation. A wireless transmitter unit transmits signals with Zigbee and a receiver unit which has two RF modules, Zigbee and Wi-Fi, receives signals from the transmitter unit and retransmits signals to the remote monitoring system with Zigbee and Wi-Fi, respectively. By using both Zigbee and Wi-Fi, the wireless sensor system can achieve a low power consumption and wide range coverage. The system's features are presented, as well as continuous monitoring results of vital signals.

  15. FFTF fission gas monitor computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be controlled by the computer, allowing the system to provide rapid system self tests and operational performance reports

  16. The dynamic state monitoring of bearings system

    Directory of Open Access Journals (Sweden)

    Marek Krynke

    2015-03-01

    Full Text Available The article discusses the methods of dynamic state monitoring of bearings system. A vibration signal contains important technical information about the machine condition and is currently the most frequently used in diagnostic bearings systems. One of the main ad-vantages of machine condition monitoring is identifying the cause of failure of the bearings and taking preventative measures, otherwise the operation of such a machine will lead to frequent replacement of the bearings. Monitoring changes in the course of the operation of machin-ery repair strategies allows keeping the conditioned state of dynamic failure conditioned preventive repairs and repairs after-failure time. In addition, the paper also presents the fundamental causes of bearing failure and identifies mechanisms related to the creation of any type of damage.

  17. Design of Simple Landslide Monitoring System

    Science.gov (United States)

    Meng, Qingjia; Cai, Lingling

    2018-01-01

    The simple landslide monitoring system is mainly designed for slope, collapse body and surface crack. In the harsh environment, the dynamic displacement data of the disaster body is transmitted to the terminal acquisition system in real time. The main body of the system adopt is PIC32MX795F512. This chip is to realize low power design, wakes the system up through the clock chip, and turns on the switching power supply at set time, which makes the wireless transmission module running during the interval to ensure the maximum battery consumption, so that the system can be stable long term work.

  18. Wireless battery management control and monitoring system

    Science.gov (United States)

    Zumstein, James M.; Chang, John T.; Farmer, Joseph C.; Kovotsky, Jack; Lavietes, Anthony; Trebes, James Edward

    2018-01-16

    A battery management system using a sensor inside of the battery that sensor enables monitoring and detection of various events in the battery and transmission of a signal from the sensor through the battery casing to a control and data acquisition module by wireless transmission. The detection of threshold events in the battery enables remedial action to be taken to avoid catastrophic events.

  19. Functional Modeling for Monitoring of Robotic System

    DEFF Research Database (Denmark)

    Wu, Haiyan; Bateman, Rikke R.; Zhang, Xinxin

    2018-01-01

    With the expansion of robotic applications in the industrial domain, it is important that the robots can execute their tasks in a safe and reliable way. A monitoring system can be implemented to ensure the detection of abnormal situations of the robots and report the abnormality to their human su...

  20. A low frequency RFI monitoring system

    Science.gov (United States)

    Amiri, Shahram; Shankar, N. Udaya; Girish, B. S.; Somashekar, R.

    Radio frequency interference (RFI) is a growing problem for research in radio astronomy particularly at wavelengths longer than 2m. For satisfactory operation of a radio telescope, several bands have been protected for radio astronomy observations by the International Telecommunication Union. Since the radiation from cosmic sources are typically 40 to 100 dB below the emission from services operating in unprotected bands, often the out-of-band emission limits the sensitivity of astronomical observations. Moreover, several radio spectral emissions from cosmic sources are present in the frequency range outside the allocated band for radio astronomy. Thus monitoring of RFI is essential before building a receiver system for low frequency radio astronomy. We describe the design and development of an RFI monitoring system operating in the frequency band 30 to 100 MHz. This was designed keeping in view our proposal to extend the frequency of operation of GMRT down to 40 MHz. The monitor is a PC based spectrometer recording the voltage output of a receiver connected to an antenna, capable of digitizing the low frequency RF directly with an 8 bit ADC and sampling bandwidths up to 16 MHz. The system can operate continuously in almost real-time with a loss of only 2% of data. Here we will present the systems design aspects and the results of RFI monitoring carried out at the Raman Research Institute, Bangalore and at the GMRT site in Khodad.

  1. A hand-hygiene behaviour monitoring system

    NARCIS (Netherlands)

    Van Schie, M.; Wiesman, R.F.F.

    2008-01-01

    The invention relates to a hand-hygiene behaviour monitoring system, comprising: means for detecting the occurrence of an event specified in a hand-hygiene rule, wherein the event involves a person; means for updating behaviour data that is related to acts according to the hand-hygiene rule, wherein

  2. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  3. A monitoring system for gypsy moth management

    Science.gov (United States)

    F. William Ravlin; S. J. Fleischer; M. R. Carter; E. A. Roberts; M. L. McManus

    1991-01-01

    Within the last ten years considerable research has been directed toward the development of a gypsy moth monitoring system for project planning at a regional level and for making control decisions at a local level. Pheromones and pheromone-baited traps have been developed and widely used and several egg mass sampling techniques have also been developed. Recently these...

  4. DIADEM: a system for collaborative environmental monitoring

    NARCIS (Netherlands)

    Winterboer, A.; Martens, M.A.; Pavlin, G.; Groen, F.C.A.; Evers, V.

    2011-01-01

    Environmental monitoring and emergency response projects in urban-industrial areas increasingly rely on efficient collaboration between experts in control rooms and at incident locations, and citizens who live or work in the area. In the video accompanying this abstract we present a system that uses

  5. Locomotive monitoring system using wireless sensor networks

    CSIR Research Space (South Africa)

    Croucamp, PL

    2014-07-01

    Full Text Available Theft of cables used for powering a locomotive not only stops the train from functioning but also paralyzes the signalling and monitoring system. This means that information on certain locomotive's cannot be passed onto other locomotives which may...

  6. A systems approach to nuclear facility monitoring

    International Nuclear Information System (INIS)

    Argo, P.E.; Doak, J.E.; Howse, J.W.

    1996-01-01

    Sensor technology for use in nuclear facility monitoring has reached an advanced stage of development. Research on where to place these sensors in a facility and how to combine their outputs in a meaningful fashion does not appear to be keeping pace. In this paper, the authors take a global view of the problem where sensor technology is viewed as only one piece of a large puzzle. Other pieces of this puzzle include the optimal location and type of sensors used in a specific facility, the rate at which sensors record information, and the risk associated with the materials/processes at a facility. If the data are analyzed off-site, how will they be transmitted? Is real-time analysis necessary? Is one monitoring only the facility itself, or might one also monitor the processing that occurs there (e.g., tank levels and concentrations)? How is one going to combine the outputs from the various sensors to give us an accurate picture of the state of the facility? This paper will not try to answer all these questions, but rather it will attempt to stimulate thought in this area by formulating a systems approach to the problem demonstrated by a prototype system and a system proposed for an actual facility. The focus will be on the data analysis aspect of the problem. Future work in this area should focus on recommendations and guidelines for a monitoring system based upon the type of facility and processing that occurs there

  7. Web Based Room Monitoring System Using Webcam

    Directory of Open Access Journals (Sweden)

    Tole Sutikno

    2008-04-01

    Full Text Available A security has become very important along with the increasing number of crime cases. If some security system fails, there is a need for a mechanism that capable in recording the criminal act. Therefore, it can be used for investigation purpose of the authorities. The objective of this research is to develop a security system using video streaming that able to monitor in real-time manner, display movies in a browser, and record a video as triggered by a sensor. This monitoring system comprises of two security level camera as a video recorder of special events based on infrared sensor that is connected to a microcontroller via serial communication and camera as a real-time room monitor. The hardware system consists of infrared sensor circuit to detect special events that is serially communicated to an AT89S51 microcontroller that controls the system to perform recording process, and the software system consists of a server that displaying video streaming in a webpage and a video recorder. The software for video recording and server camera uses Visual Basic 6.0 and for video streaming uses PHP 5.1.6. As the result, the system can be used to record special events that it is wanted, and can displayed video streaming in a webpage using LAN infrastructure.

  8. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Cortes-Gonzalez, Arely; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two photomultiplier in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator based readout system. Combined information from all systems allows to monitor and equalise the calorimeter r...

  9. Master Console System Monitoring and Control Development

    Science.gov (United States)

    Brooks, Russell A.

    2013-01-01

    The Master Console internship during the spring of 2013 involved the development of firing room displays at the John F. Kennedy Space Center (KSC). This position was with the Master Console Product Group (MCPG) on the Launch Control System (LCS) project. This project is responsible for the System Monitoring and Control (SMC) and Record and Retrieval (R&R) of launch operations data. The Master Console is responsible for: loading the correct software into each of the remaining consoles in the firing room, connecting the proper data paths to and from the launch vehicle and all ground support equipment, and initializing the entire firing room system to begin processing. During my internship, I developed a system health and status display for use by Master Console Operators (MCO) to monitor and verify the integrity of the servers, gateways, network switches, and firewalls used in the firing room.

  10. Mobile Monitoring System for Nuclear Contamination Analysis

    International Nuclear Information System (INIS)

    Broide, A.; Sheinfeld, M.; Marcus, E.; Wengrowicz, U.; Tirosh, D.

    2002-01-01

    In case of a nuclear accident, it is essential to have extensive knowledge concerning the nature of the radioactive plume expansion, for further analysis. For this purpose a mobile monitoring system may provide important data about the plume characteristics. An advanced Mobile Monitoring System is under development at the Nuclear Research Center-Negev. The system is composed of a network of mobile stations, typically installed onboard vehicles, which transmit radiation measurements along with position information to a central station. The mobile network's communications infrastructure is based on Motorola Mobile Logic Unit devices, which are state-of-the-art reliable modems with an integrated Global Positioning System module. The radiation measurements received by the central station are transferred to a risk assessment program, which evaluates the expected hazards to the populated areas located in the estimated plume's expansion direction

  11. System specification for the integrated monitoring and surveillance system

    International Nuclear Information System (INIS)

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides

  12. Condition Indicators for Gearbox Condition Monitoring Systems

    Directory of Open Access Journals (Sweden)

    P. Večeř

    2005-01-01

    Full Text Available Condition monitoring systems for manual transmissions based on vibration diagnostics are widely applied in industry. The systems deal with various condition indicators, most of which are focused on a specific type of gearbox fault. Frequently used condition indicators (CIs are described in this paper. The ability of a selected condition indicator to describe the degree of gearing wear was tested using vibration signals acquired during durability testing of manual transmission with helical gears. 

  13. AIR TICKETS RATES MONITORING: INFORMATION SYSTEM DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Oleg Smirnov

    2015-05-01

    Full Text Available In the article conduct analysis of preconditions of air tickets fares dynamics. Monitoring informational system formation in aim of public regulation of air transport on base of an assessment of the current state and development prospects of Russian civil aviation, and formed the conceptual basis for information system architecture at the levels of the presentation layer, business-logic and data access layer.

  14. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  15. Wireless monitoring system for personal dose

    International Nuclear Information System (INIS)

    Kobayashi, Hironobu; Kawamura, Takeshi; Inoue, Takayuki

    2000-01-01

    Fuji Electric has developed a system for the higher radiation controlled area in nuclear power plants, in which exposure dose data measured on the wearer's chest, hands, and legs are transferred by wireless to the data control equipment so that the exposure dose can be controlled in real time. The system using a specified low-power radio wave causes no interference to the other types of dosimeters. The data control equipment automatically saves data received from the dosimeters and also has functions of calibration of dosimeters and maintenance of the wireless system. This paper describes the wireless monitoring system that consists of chest and parts dosimeters and data control equipment. (author)

  16. Weight monitoring system for newborn incubator application

    Science.gov (United States)

    Widianto, Arif; Nurfitri, Intan; Mahatidana, Pradipta; Abuzairi, Tomy; Poespawati, N. R.; Purnamaningsih., Retno W.

    2018-02-01

    We proposed weight monitoring system using load cell sensor for newborn incubator application. The weight sensing system consists of a load cell, conditioning signal circuit, and microcontroller Arduino Uno R3. The performance of the sensor was investigated by using the various weight from 0 up to 3000 g. Experiment results showed that this system has a small error of 4.313% and 12.5 g of threshold and resolution value. Compared to the typical baby scale available in local market, the proposed system has a lower error value and hysteresis.

  17. Multistandard Receiver Design for Telemedicine Monitoring System

    Directory of Open Access Journals (Sweden)

    Hongmei Wang

    2018-01-01

    Full Text Available In short-distance wireless communications for telemedicine monitoring, different medical data measurement equipment has different wireless transmission modes. A multistandard receiver is designed that can adapt to different medical data measuring equipment. Using a second-order bandpass sampling for the design of antialiasing filters, two aliasing signals can be separated. Simultaneously, constraint conditions for sampling frequency are not as critical. The design is useful for a multistandard receiver in a telemedicine monitoring system and has the advantages such as saving spectrum resources and facilitating spectrum planning.

  18. Development of in-situ monitoring system

    International Nuclear Information System (INIS)

    Lee, Bong Soo; Cho, Dong Hyun; Yoo, Wook Jae; Heo, Ji Yeon

    2010-03-01

    Development of in-situ monitoring system using an optical fiber to measure the real time temperature variation of subsurface water for the evaluation of flow characteristics. We describe the feasibility of developing a fiber-optic temperature sensor using a thermochromic material. A sensor-tip is fabricated by mixing of a thermochromic material powder. The relationships between the temperatures and the output voltages of detectors are determined to measure the temperature of water. It is expected that the fiber-optic temperature monitoring sensor using thermochromic material can be used to measure the real time temperature variation of subsurface water

  19. Infrared system for monitoring movement of objects

    Science.gov (United States)

    Valentine, Kenneth H.; Falter, Diedre D.; Falter, Kelly G.

    1991-01-01

    A system for monitoring moving objects, such as the flight of honeybees and other insects, using a pulsed laser light source. This system has a self-powered micro-miniaturized transmitting unit powered, in the preferred embodiment, with an array solar cells. This transmitting unit is attached to the object to be monitored. These solar cells provide current to a storage energy capacitor to produce, for example, five volts for the operation of the transmitter. In the simplest embodiment, the voltage on the capacitor operates a pulse generator to provide a pulsed energizing signal to one or more very small laser diodes. The pulsed light is then received at a receiving base station using substantially standard means which converts the light to an electrical signal for processing in a microprocessor to create the information as to the movement of the object. In the case of a unit for monitoring honeybees and other insects, the transmitting unit weighs less than 50 mg, and has a size no larger than 1.times.3.times.5 millimeters. Also, the preferred embodiment provides for the coding of the light to uniquely identify the particular transmitting unit that is being monitored. A "wake-up" circuit is provided in the preferred embodiment whereby there is no transmission until the voltage on the capacitor has exceeded a pre-set threshold. Various other uses of the motion-detection system are described.

  20. Geological hazard monitoring system in Georgia

    Science.gov (United States)

    Gaprindashvili, George

    2017-04-01

    Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.

  1. Intelligent monitoring system of bedridden elderly

    Science.gov (United States)

    Dong, Rue Shao; Tanaka, Motohiro; Ushijima, Miki; Ishimatsu, Takakazu

    2005-12-01

    In this paper we propose a system to detect physical behavior of the elderly under bedridden status. This system is used to prevent those elderly from falling down and being wounded. Basic idea of our approach is to measure the body movements of the elderly using the acceleration sensor. Based on the data measured, dangerous actions of the elderly are extracted and warning signals to the caseworkers are generated via wireless signals. A feature of the system is that the senor part is compactly assembled as a wearable unit. Another feature of the system is that the system adopts a simplified wireless network system. Due to the network capability the system can monitor physical movements of multi-patients. Applicability of the system is now being examined at hospitals.

  2. Methods, apparatus, and systems for monitoring transmission systems

    Science.gov (United States)

    Polk, Robert E [Idaho Falls, ID; Svoboda, John M [Idaho Falls, ID; West, Phillip B [Idaho Falls, ID; Heath, Gail L [Iona, ID; Scott, Clark L [Idaho Falls, ID

    2010-08-31

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  3. Networked Biomedical System for Ubiquitous Health Monitoring

    Directory of Open Access Journals (Sweden)

    Arjan Durresi

    2008-01-01

    Full Text Available We propose a distributed system that enables global and ubiquitous health monitoring of patients. The biomedical data will be collected by wearable health diagnostic devices, which will include various types of sensors and will be transmitted towards the corresponding Health Monitoring Centers. The permanent medical data of patients will be kept in the corresponding Home Data Bases, while the measured biomedical data will be sent to the Visitor Health Monitor Center and Visitor Data Base that serves the area of present location of the patient. By combining the measured biomedical data and the permanent medical data, Health Medical Centers will be able to coordinate the needed actions and help the local medical teams to make quickly the best decisions that could be crucial for the patient health, and that can reduce the cost of health service.

  4. Advanced condition monitoring program for turbine system

    International Nuclear Information System (INIS)

    Ono, Shigetoshi

    2015-01-01

    It is important for utilities to achieve a stable operation in nuclear power plants. To achieve it, plant anomalies that affect a stable operation must be found out and eliminated. Therefore, the advanced condition monitoring program was developed. In this program, a sophisticated heat balance model based on the actual plant data is adopted to identify plant anomalies at an incipient stage and the symptoms of plant anomalies are found by heat balance changes from the model calculation. The model calculation results have shown precise prediction for actual plant parameters. Moreover, this program has the diagnostic engine that helps operators derive the cause of plant anomalies. By using this monitoring program, the component reliability in the turbine system can be periodically monitored and assessed, and as a result the stable operation of nuclear power plants can be achieved. (author)

  5. A new venous infusion pathway monitoring system.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2007-01-01

    A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.

  6. Quebec firm develops satellite monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2004-09-01

    Satellite-based technology that gives project owners an affordable way to monitor and control wind turbine operation, even in remote sites, is announced. Called Satwind, the system can be adapted to any scale, ranging from simple, low-cost units for small wind turbines to advanced versions designed to handle more complex wind-diesel installations, as well as large turbines used in offshore projects. Current installations include a turbine in the Tunisian desert and two Quebec wind-diesel plants accessible only by helicopter. The system can be operated directly from a cell-phone, in a user-friendly Internet manner, without the need to be connected to a complex centralized wind farm monitoring system.

  7. Environmental monitoring with a portable TLD system

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, P P; Feher, I; Deme, S; Szabo, B; Vagvoelgyi, J; German, E [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    Two types of TLD systems are used for environmental dose monitoring. One is based on an NHZ-203 laboratory TLD reader and CaSO/sub 4/:Dy powder. The other is based on CaSO/sub 4/:Tm bulbs and a small, portable TLD reader built into a cross-country car and operated by means of the car battery. The laboratory TLD system has been used for many years for environmental monitoring and it has been tested and proved satisfactory at international intercomparisons for environmental dosemeters. The new portable TLD system has the advantage of being able to establish the dose in a few minutes at the environmental station. The transport dose is omitted as the TLDs are evaluated at the field site. The evaluation of a bulb needs only a few minutes and the measured dose value can be reported back by radio - an important aspect during an emergency situation.

  8. A design methodology for unattended monitoring systems

    International Nuclear Information System (INIS)

    SMITH, JAMES D.; DELAND, SHARON M.

    2000-01-01

    The authors presented a high-level methodology for the design of unattended monitoring systems, focusing on a system to detect diversion of nuclear materials from a storage facility. The methodology is composed of seven, interrelated analyses: Facility Analysis, Vulnerability Analysis, Threat Assessment, Scenario Assessment, Design Analysis, Conceptual Design, and Performance Assessment. The design of the monitoring system is iteratively improved until it meets a set of pre-established performance criteria. The methodology presented here is based on other, well-established system analysis methodologies and hence they believe it can be adapted to other verification or compliance applications. In order to make this approach more generic, however, there needs to be more work on techniques for establishing evaluation criteria and associated performance metrics. They found that defining general-purpose evaluation criteria for verifying compliance with international agreements was a significant undertaking in itself. They finally focused on diversion of nuclear material in order to simplify the problem so that they could work out an overall approach for the design methodology. However, general guidelines for the development of evaluation criteria are critical for a general-purpose methodology. A poor choice in evaluation criteria could result in a monitoring system design that solves the wrong problem

  9. Helmet-based physiological signal monitoring system.

    Science.gov (United States)

    Kim, Youn Sung; Baek, Hyun Jae; Kim, Jung Soo; Lee, Haet Bit; Choi, Jong Min; Park, Kwang Suk

    2009-02-01

    A helmet-based system that was able to monitor the drowsiness of a soldier was developed. The helmet system monitored the electrocardiogram, electrooculogram and electroencephalogram (alpha waves) without constraints. Six dry electrodes were mounted at five locations on the helmet: both temporal sides, forehead region and upper and lower jaw strips. The electrodes were connected to an amplifier that transferred signals to a laptop computer via Bluetooth wireless communication. The system was validated by comparing the signal quality with conventional recording methods. Data were acquired from three healthy male volunteers for 12 min twice a day whilst they were sitting in a chair wearing the sensor-installed helmet. Experimental results showed that physiological signals for the helmet user were measured with acceptable quality without any intrusions on physical activities. The helmet system discriminated between the alert and drowsiness states by detecting blinking and heart rate variability (HRV) parameters extracted from ECG. Blinking duration and eye reopening time were increased during the sleepiness state compared to the alert state. Also, positive peak values of the sleepiness state were much higher, and the negative peaks were much lower than that of the alert state. The LF/HF ratio also decreased during drowsiness. This study shows the feasibility for using this helmet system: the subjects' health status and mental states could be monitored without constraints whilst they were working.

  10. System for monitoring microclimate conditions in greenhouse

    Directory of Open Access Journals (Sweden)

    Marković Dušan B.

    2014-01-01

    Full Text Available Monitoring microclimate parameters in different kind of environments has significant contribution to many areas of human activity and production processes. One of them is vegetable production in greenhouses where measurement of its microclimate parameters may influence the decision on taking appropriate action and protect crops. It is also important to preserve optimal condition in greenhouses to facilitate the process of transpiration, plant mineral nutrition and prevent of a variety physiological damage caused by a deficit of some specific nutrients. Systems for monitoring have wide application in the last years thanks to development of modern computer technology. In this paper model of the monitoring system based on smart transducer concept was introduced. Within the system components are based on MSP430 ultra low power micro controllers. They are using wireless communication to exchange data within the system that was structured according to smart transducer concept. User applications from the network could access to system interface using HTTP protocol where web server could be running on the computer or it could be an embedded web server running on micro controller based device.

  11. Automated system for data acquisition and monitoring

    Directory of Open Access Journals (Sweden)

    Borza Sorin

    2017-01-01

    Full Text Available The Environmental management has become, with the development of human society a very important issue. There have been multiple systems that automatically monitors the environment. In this paper we propose a system that integrates GIS software and data acquisition software. In addition the proposed system implements new AHP multicriteria method that can get an answer online on each pollutant influence on limited geographical area in which the monitors. Factors pollutants of limited geographical areas are taken automatically by specific sensors through acquisition board. Labview software, with virtual instrument created by transferring them into a database Access. Access database they are taken up by software Geomedia Professional and processed using multi-criteria method AHP, so that at any moment, their influence on the environment and classify these influences, can be plotted on the screen monitoring system. The system allows, the automatic collection of data, the memorization and the generation of GIS elements. The research presented in this paper were aimed at implementing multi-criteria methods in GIS software.

  12. Non Invasive Glucose Monitoring System Using Nanosensors

    Directory of Open Access Journals (Sweden)

    Rajasekaran C.

    2016-03-01

    Full Text Available The most existing future technology is an outcome of the fields of computer science, electronics and Biology. Health inequalities have become the focus of a number of descriptive and analytical studies. One of the health related problem is diabetes. Diabetes at its serious stage leads to blindness. Monitoring glucose level in blood is one preventive measure to check diabetes. Increase in Glucose is a common risk factor which leads to hyperglycemia, Hypoglycemia, heart attack, stokes and aneurysms. A glucose monitoring system continuously measures and monitors the glucose level in a patient’s blood. Normal blood glucose level of human is 70-110 milligram/deciliter. The level is maintained by using the secretion of insulin inside the body. When the insulin level gets increased it leads to hyperglycemia, and hypoglycemia when the level gets decreased. Hyperglycemia disease includes cataract,edema, hypertension, polyuria and polydipsia. Hypoglycemaia disease includes confusion, giddiness, unconsciousness, coma and death. The proposed system finds a new way for measuring the glucose level. The work uses Nanopellets which measure’s the glucose level, when the glucose level gets increased or decreased, it will be automatically get monitored and processed using microcontroller (MSP430G2553. The information is then send to the doctor through GSM.

  13. Beam position monitor system for storage rings

    International Nuclear Information System (INIS)

    Nakamura, M.; Hinkson, J.A.

    1985-05-01

    Beam position monitors (BPM) for synchrotron light storage rings usually consist of beam pickup electrodes, coaxial relays and a narrowband receiver. While accurate, these systems are slow and of limited use in the commissioning of an accelerator. A beam position monitor is described which is intended to be a principal diagnostic during debug and routine running of a storage ring. It is capable of measuring the position of a single bunch on the first or nth orbit to an accuracy of a few percent. Stored beam position is more accurately measured with averaging techniques. Beam position changes can be studied in a bandwidth from DC to a few MHz. The beam monitor electronics consist of a separate amplification, detection, and sampling channel for each beam pickup electrode. Fast switches in each channel permit selection of the nth turn for measurement (single bunch mode). A calibration pulse is injected into each channel after beam measurement to permit gain offsets to be measured and removed from the final data. While initially more costly than the usual beam position monitor system, this sytem will pay for itself in reduced storage ring debug and trouble shooting time. 5 refs., 5 figs

  14. Fermilab accelerator control system: Analog monitoring facilities

    International Nuclear Information System (INIS)

    Seino, K.; Anderson, L.; Smedinghoff, J.

    1987-10-01

    Thousands of analog signals are monitored in different areas of the Fermilab accelerator complex. For general purposes, analog signals are sent over coaxial or twinaxial cables with varying lengths, collected at fan-in boxes and digitized with 12 bit multiplexed ADCs. For higher resolution requirements, analog signals are digitized at sources and are serially sent to the control system. This paper surveys ADC subsystems that are used with the accelerator control systems and discusses practical problems and solutions, and it describes how analog data are presented on the console system

  15. Monitoring and crisis system of radiation safety

    International Nuclear Information System (INIS)

    Bartok, J.; Borovansky, P.; Macica, J.; Petrovicova, M.

    2005-01-01

    In this paper we have briefly described our practical experiences with the most complex Radiation Monitoring System we have designed. This system consists of number of stations; those data are collected in the main crisis center of the whole system. The main center integrates RMS Central Database, the IMS Model Suite workstation and the Graphics workstation. The radiations probes of the RP series are the base for stationary , portable sets and for sets measuring underwater radiation. The radiation and meteorological data, which are necessary for reasonable interpretation of radiation data, are archived in RMS Central database. The Lagrangian trajectory model from the IMS Model Suite serves for radiation dispersion modeling. (authors)

  16. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  17. Quaternion Based Thermal Condition Monitoring System

    Science.gov (United States)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.

  18. Integrated monitoring of wind plant systems

    Science.gov (United States)

    Whelan, Matthew J.; Janoyan, Kerop D.; Qiu, Tong

    2008-03-01

    Wind power is a renewable source of energy that is quickly gaining acceptance by many. Advanced sensor technologies have currently focused solely on improving wind turbine rotor aerodynamics and increasing of the efficiency of the blade design and concentration. Alternatively, potential improvements in wind plant efficiency may be realized through reduction of reactionary losses of kinetic energy to the structural and substructural systems supporting the turbine mechanics. Investigation of the complete dynamic structural response of the wind plant is proposed using a large-scale, high-rate wireless sensor network. The wireless network enables sensors to be placed across the sizable structure, including the rotating blades, without consideration of cabling issues and the economic burden associated with large spools of measurement cables. A large array of multi-axis accelerometers is utilized to evaluate the modal properties of the system as well as individual members and would enable long-term structural condition monitoring of the wind turbine as well. Additionally, environmental parameters, including wind speed, temperature, and humidity, are wirelessly collected for correlation. Such a wireless system could be integrated with electrical monitoring sensors and actuators and incorporated into a remote multi-turbine centralized plant monitoring and control system.

  19. Honey Bee Colonies Remote Monitoring System

    Directory of Open Access Journals (Sweden)

    Sergio Gil-Lebrero

    2016-12-01

    Full Text Available Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD. The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time.

  20. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  1. The AGS Booster beam loss monitor system

    International Nuclear Information System (INIS)

    Beadle, E.R.; Bennett, G.W.; Witkover, R.L.

    1991-01-01

    A beam loss monitor system has been developed for the Brookhaven National Laboratory Booster accelerator, and is designed for use with intensities of up to 1.5 x 10 13 protons and carbon to gold ions at 50-3 x 10 9 ions per pulse. This system is a significant advance over the present AGS system by improving the sensitivity, dynamic range, and data acquisition. In addition to the large dynamic range achievable, it is adaptively shifted when high losses are detected. The system uses up to 80 argon filled ion chambers as detectors, as well as newly designed electronics for processing and digitizing detector outputs. The hardware simultaneously integrates each detector output, interfaces to the beam interrupt systems, and digitizes all 80 channels to 21 bits at 170 KHz. This paper discuses the design, construction, and operation of the system. 4 refs., 2 figs

  2. A new system for radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.

    1993-01-01

    The Finnish authorities are acquiring a new radiation monitoring system enabling realtime transmission of information on the radiation situation. The system will also gather meteorological data and make predictions on the movements of a radioactive cloud. The data are stored in a database, from which they can be retrieved onto a user's workstation. Each user can get an overall picture of the current situation by viewing a set of files which are produced automatically by the system. Upon receiving notice of a hazard, the system contacts the paging devices of the officers on call. When the notice comes from a single station, the system automatically reads the measurement data of all stations within 50 kilometers. The system, development of which began in 1992, will be put to use early next year. (orig.)

  3. Service models for remote healthcare monitoring systems.

    Science.gov (United States)

    Moorman, Bridget A

    2010-01-01

    These scenarios reflect where the future is heading for remote health monitoring technology and service expectations. Being able to manage a "system of systems" with timely service hand-off over seams of responsibility and system interfaces will become very important for a BMET or clinical engineer. These interfaces will include patient homes, clinician homes, commercial/civilian infrastructure, public utilities, vendor infrastructure as well as internal departmental domains. Concurrently, technology is changing rapidly resulting in newer software delivery modes and hardware appliances as well as infrastructure changes. Those who are able to de-construct the complex systems and identify infrastructure assumptions and seams of servicing responsibility will be able to better understand and communicate the expectations for service of these systems. Moreover, as identified in Case 1, prodigious use of underlying system monitoring tools (managing the "meta-data") could move servicing of these remote systems from a reactive approach to a proactive approach. A prepared healthcare organization will identify their current and proposed future service combination use cases and design service philosophies and expectations for those use cases, while understanding the infrastructure assumptions and seams of responsibility. This is the future of technical service to the healthcare clinicians and patients.

  4. Production monitoring system for understanding product robustness

    DEFF Research Database (Denmark)

    Boorla, Srinivasa Murthy; Howard, Thomas J.

    2016-01-01

    study is used to demonstrate how the monitoring system can be used to efficiently guide corrective action to improve product performance. It is claimed that the monitoring system can be used to dramatically cut the time taken to identify, planand execute corrective action related to typical quality......In the current quality paradigm, the performance of a product is kept within specification by ensuring that its parts are within specification. Product performance is then validated after final assembly. However, this does not control how robust the product performance is, i.e. how much...... it will vary between the specification limits. In this paper, a model for predicting product performance is proposed, taking into account design, assembly and process parameters live from production. This empowers production to maintain final product performance, instead of part quality. The PRECI‐IN case...

  5. The Argentine remote monitoring and surveillance system

    International Nuclear Information System (INIS)

    Bonino, A.; Roca, J.L.; Perez, A.; Pizarro, L.; Krimer, M.; Teira, R.; Higa, Z.; Saettone, S.; Monzon, J.; Moroni, D.

    1996-01-01

    The Scientific and Technical Support Department of the Argentine National Board of Nuclear Regulation (ENREN) has developed a Remote Monitoring and Surveillance System (RMSS) that provides a media to verify state of variables related to the monitoring and surveillance activities of nuclear facilities, mainly safeguard applications. RMSS includes a variety of on site installed sensors, an authenticated radiofrequency communication link, a receiver processing unit, an active vision set and a user friendly personal computer interface to collect, view and store pertinent histories of events. A real time data base allows consulting, maintenance, updating and checking activities. RMSS could be integrated into a LAN or WAN via modem for use in a remote operation scheme. In this paper a description of the RMSS is provided. Also, an overview of the RMSS operation at one facility under safeguards belonging to the National Commission of Atomic Energy (CNEA) is presented. Results and conclusions of the system associated with this facility are given. (author). 37 figs

  6. A VME based health monitoring system

    International Nuclear Information System (INIS)

    Huang Yiming; Wang Chunhong

    2011-01-01

    It introduces a VME based health system for monitoring the working status of VME crates in the BEPCⅡ. It consists of a PC and a VME crate where a CMM (Classic Monitor System) is installed. The CMM module is responsible for collecting data from the power supply and temperature as well as fan speed inside the VME crate and send these data to the PC via the serial port. The author developed EPICS asynchronous driver by using a character-based device protocol StreamDevice. The data is saved into EPICS IOC database in character. Man-machine interface which is designed by BOY displays the running status of the VME crate including the power supply and temperature as well as fan speed. If the value of records display unusual, the color of the value will be changed into red. This can facilitate the maintenance of the VME crates. (authors)

  7. Software for airborne radiation monitoring system

    International Nuclear Information System (INIS)

    Sheinfeld, M.; Kadmon, Y.; Tirosh, D.; Elhanany, I.; Gabovitch, A.; Barak, D.

    1997-01-01

    The Airborne Radiation Monitoring System monitors radioactive contamination in the air or on the ground. The contamination source can be a radioactive plume or an area contaminated with radionuclides. This system is composed of two major parts: Airborne Unit carried by a helicopter, and Ground Station carried by a truck. The Airborne software is intended to be the core of a computerized airborne station. The software is written in C++ under MS-Windows with object-oriented methodology. It has been designed to be user-friendly: function keys and other accelerators are used for vital operations, a help file and help subjects are available, the Human-Machine-Interface is plain and obvious. (authors)

  8. The Argentine remote monitoring and surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, A; Roca, J L; Perez, A; Pizarro, L; Krimer, M; Teira, R; Higa, Z; Saettone, S; Monzon, J; Moroni, D [Ente Nacional Regulador Nuclear, Buenos Aires (Argentina). Dept. Apoyo Cientifico y Tecnico

    1997-12-31

    The Scientific and Technical Support Department of the Argentine National Board of Nuclear Regulation (ENREN) has developed a Remote Monitoring and Surveillance System (RMSS) that provides a media to verify state of variables related to the monitoring and surveillance activities of nuclear facilities, mainly safeguard applications. RMSS includes a variety of on site installed sensors, an authenticated radiofrequency communication link, a receiver processing unit, an active vision set and a user friendly personal computer interface to collect, view and store pertinent histories of events. A real time data base allows consulting, maintenance, updating and checking activities. RMSS could be integrated into a LAN or WAN via modem for use in a remote operation scheme. In this paper a description of the RMSS is provided. Also, an overview of the RMSS operation at one facility under safeguards belonging to the National Commission of Atomic Energy (CNEA) is presented. Results and conclusions of the system associated with this facility are given. (author). 37 figs.

  9. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00445232; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  10. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00445232; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises cesium radioactive sources, Laser and charge injection elements, and allows for monitoring and equalization of the calorimeter response at each stage of the signal production, ...

  11. The RM-5000 system for radiation monitoring

    International Nuclear Information System (INIS)

    1997-01-01

    Eight models of radiation monitors can be assembled from independent modules for the agricultural firms, customs house, boundary transitions, for the control of transport and passenger flows and for prevention of the non-authorized moving of radioactive and fissionable materials. Two modules are a basis of the system - gamma radiation detector on the basis of plastic scintillator and neutrons detector on the basis of the proportional 3 He counters

  12. [Maintenance and monitoring of water treatment system].

    Science.gov (United States)

    Pontoriero, G; Pozzoni, P; Tentori, F; Scaravilli, P; Locatelli, F

    2005-01-01

    Water treatment systems must be submitted to maintenance, disinfections and monitoring periodically. The aim of this review is to analyze how these processes must complement each other in order to preserve the efficiency of the system and optimize the dialysis fluid quality. The correct working of the preparatory process (pre-treatment) and the final phase of depuration (reverse osmosis) of the system need a periodic preventive maintenance and the regular substitution of worn or exhausted components (i.e. the salt of softeners' brine tank, cartridge filters, activated carbon of carbon tanks) by a competent and trained staff. The membranes of reverse osmosis and the water distribution system, including dialysis machine connections, should be submitted to dis-infections at least monthly. For this purpose it is possible to use chemical and physical agents according to manufacturer' recommendations. Each dialysis unit should predispose a monitoring program designed to check the effectiveness of technical working, maintenance and disinfections and the achievement of chemical and microbiological standards taken as a reference. Generally, the correct composition of purified water is monitored by continuous measuring of conductivity, controlling bacteriological cultures and endotoxin levels (monthly) and checking water contaminants (every 6-12 months). During pre-treatment, water hardness (after softeners) and total chlorine (after chlorine tank) should be checked periodically. Recently the Italian Society of Nephrology has developed clinical guidelines for water and dialysis solutions aimed at suggesting rational procedures for production and monitoring of dialysis fluids. It is hopeful that the application of these guidelines will lead to a positive cultural change and to an improvement in dialysis fluid quality.

  13. Development of CANDU core monitoring system

    International Nuclear Information System (INIS)

    Yoon, M. Y.; Yeam, C. S.; Kwon, O. H.; Kim, K. H.

    2003-01-01

    The research was performed to develop a CANDU Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong Nuclear Power Plant(NPP) No. 1. CCMS uses RFSP(Reactor Fueling Simulation Program) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from DCC(Digital Control Computer) for the purpose of producing basic input data. CCMS could be largely divided into two modules; CCMS server program and CCMS client program. CCMS server program plays the role in automatic and continuous RFSP run and management of the past output data resulting from the run using Data Base Management System(DBMS). CCMS client program enables users to monitor current and past core status with GUI(Graphic-User Interface) environment predefined. The effectiveness of CCMS was verified by comparing the data resulted from field-test of the system for about 43 hours with the data used in the field of Wolsong NPP No. 1

  14. Development of CANDU core monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, M. Y.; Yeam, C. S.; Kwon, O. H.; Kim, K. H. [Institute for Advanced Engineering, Yongin (Korea, Republic of)

    2003-07-01

    The research was performed to develop a CANDU Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong Nuclear Power Plant(NPP) No. 1. CCMS uses RFSP(Reactor Fueling Simulation Program) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from DCC(Digital Control Computer) for the purpose of producing basic input data. CCMS could be largely divided into two modules; CCMS server program and CCMS client program. CCMS server program plays the role in automatic and continuous RFSP run and management of the past output data resulting from the run using Data Base Management System(DBMS). CCMS client program enables users to monitor current and past core status with GUI(Graphic-User Interface) environment predefined. The effectiveness of CCMS was verified by comparing the data resulted from field-test of the system for about 43 hours with the data used in the field of Wolsong NPP No. 1.

  15. A system approach to nuclear facility monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Argo, P.E.; Doak, J.E.; Howse, J.W.

    1996-09-01

    Sensor technology for use in nuclear facility monitoring has reached and advanced stage of development. Research on where to place these sensors in a facility and how to combine their outputs in a meaningful fashion does not appear to be keeping pace. In this paper, we take a global view of the problem where sensor technology is viewed as only one piece of a large puzzle. Other pieces of this puzzle include the optimal location and type of sensors used in a specific facility, the rate at which sensors record information, and the risk associated with the materials/processes at a facility. If the data are analyzed off-site, how will they be transmitted? Is real-time analysis necessary? Are we monitoring only the facility itself, or might we also monitor the processing that occurs there? How are we going to combine the output from the various sensors to give us an accurate picture of the state of the facility? This paper will not try to answer all these questions, but rather it will attempt to stimulate thought in this area by formulating a systems approach to the problem demonstrated by a prototype system and a systems proposed for an actual facility. Our focus will be on the data analysis aspect of the problem.

  16. ATLAS Tile Calorimeter calibration and monitoring systems

    Science.gov (United States)

    Cortés-González, Arely

    2018-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. Neutral particles may also produce a signal after interacting with the material and producing charged particles. The readout is segmented into about 5000 cells, each of them being read out by two photomultipliers in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. This comprises Cesium radioactive sources, Laser, charge injection elements and an integrator based readout system. Information from all systems allows to monitor and equalise the calorimeter response at each stage of the signal production, from scintillation light to digitisation. Calibration runs are monitored from a data quality perspective and used as a cross-check for physics runs. The data quality efficiency achieved during 2016 was 98.9%. These calibration and stability of the calorimeter reported here show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.

  17. Beam loss monitor system for machine protection

    CERN Document Server

    Dehning, B

    2005-01-01

    Most beam loss monitoring systems are based on the detection of secondary shower particles which depose their energy in the accelerator equipment and finally also in the monitoring detector. To allow an efficient protection of the equipment, the likely loss locations have to be identified by tracking simulations or by using low intensity beams. If superconducting magnets are used for the beam guiding system, not only a damage protection is required but also quench preventions. The quench levels for high field magnets are several orders of magnitude below the damage levels. To keep the operational efficiency high under such circumstances, the calibration factor between the energy deposition in the coils and the energy deposition in the detectors has to be accurately known. To allow a reliable damage protection and quench prevention, the mean time between failures should be high. If in such failsafe system the number of monitors is numerous, the false dump probability has to be kept low to keep a high operation...

  18. A novel continuous subcutaneous lactate monitoring system.

    Science.gov (United States)

    Poscia, A; Messeri, D; Moscone, D; Ricci, F; Valgimigli, F

    2005-05-15

    A novel continuous lactate monitoring system has been developed modifying the GlucoDay portable medical device (A. Menarini Diagnostics), already present in the European market, and used to continuously measure glucose levels. Lactate oxidase based biosensors have been developed immobilising the enzyme on nylon net and placing it on a Pt electrode. The biosensor was connected to the portable device provided with a micro-pump and coupled to a microdialysis system. It is capable to record subcutaneous lactate every 3 min. In vitro analytical results confirmed that the sensors respond linearly in the interval of concentration between 0.1 and 10 mmol/L, covering the whole physiological range. During prolonged monitoring periods, the response of the biosensors remained stable, showing a limited drift of 8%, within 60 h. Stability tests are still on route. However, preliminary results have shown a shelf life of about 10 months. In vivo experiments performed on healthy rabbits have demonstrated the good accuracy and reproducibility of the system. A correlation coefficient equal to 0.9547 (N=80) was found, which represents a good correlation between the GlucoDay and the laboratory reference analyser. A 16 h in vivo monitoring on a healthy volunteer has been also performed.

  19. Hybrid Wireless Hull Monitoring System for Naval Combat Vessels

    Science.gov (United States)

    2010-03-01

    Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system

  20. Microcomputer-based monitoring and control system

    International Nuclear Information System (INIS)

    Talaska, D.

    1979-03-01

    This report describes a microcomputer-based monitoring and control system devised within, and used by, the Cryogenic Operations group at SLAC. Presently, a version of it is operating at the one meter liquid hydrogen bubble chamber augmenting the conventional pneumatic and human feedback system. Its use has greatly improved the controlled tolerances of temperature and pulse shape, and it has nearly eliminated the need for operating personnel to adjust the conventional pneumatic control system. The latter is most important since the rapid cycling machine can demand attentions beyond the operator's skill. Similar microcomputer systems are being prepared to monitor and control cryogenic devices situated in regions of radiation which preclude human entry and at diverse locations which defy the dexterity of the few operators assigned to maintain them. An IMSAI 8080 microcomputer is basic to the system. The key to the use of the IMSAI 8080 in this system was in the development of unique interface circuitry, and the report is mostly concerned with this

  1. Reactor coolant pump monitoring and diagnostic system

    International Nuclear Information System (INIS)

    Singer, R.M.; Gross, K.C.; Walsh, M.; Humenik, K.E.

    1990-01-01

    In order to reliably and safely operate a nuclear power plant, it is necessary to continuously monitor the performance of numerous subsystems to confirm that the plant state is within its prescribed limits. An important function of a properly designed monitoring system is the detection of incipient faults in all subsystems (with the avoidance of false alarms) coupled with an information system that provides the operators with fault diagnosis, prognosis of fault progression and recommended (either automatic or prescriptive) corrective action. In this paper, such a system is described that has been applied to reactor coolant pumps. This system includes a sensitive pattern-recognition technique based upon the sequential probability ratio test (SPRT) that detects incipient faults from validated signals, an expert system embodying knowledge bases on pump and sensor performance, extensive hypertext files containing operating and emergency procedures as well as pump and sensor information and a graphical interface providing the operator with easily perceived information on the location and character of the fault as well as recommended corrective action. This system is in the prototype stage and is currently being validated utilizing data from a liquid-metal cooled fast reactor (EBR-II). 3 refs., 4 figs

  2. Low temperature monitoring system for subsurface barriers

    Science.gov (United States)

    Vinegar, Harold J [Bellaire, TX; McKinzie, II Billy John [Houston, TX

    2009-08-18

    A system for monitoring temperature of a subsurface low temperature zone is described. The system includes a plurality of freeze wells configured to form the low temperature zone, one or more lasers, and a fiber optic cable coupled to at least one laser. A portion of the fiber optic cable is positioned in at least one freeze well. At least one laser is configured to transmit light pulses into a first end of the fiber optic cable. An analyzer is coupled to the fiber optic cable. The analyzer is configured to receive return signals from the light pulses.

  3. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad; Ouda, Mahmoud H.; Marnat, Loic; Shamim, Atif; Salama, Khaled N.

    2013-01-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  4. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  5. Automated Cryocooler Monitor and Control System

    Science.gov (United States)

    Britcliffe, Michael J.; Hanscon, Theodore R.; Fowler, Larry E.

    2011-01-01

    A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and

  6. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  7. Expert systems for protective monitoring of facilities

    International Nuclear Information System (INIS)

    Carr, K.R.

    1987-01-01

    In complex plants, the possibility of serious operator error always exists to some extent, but, this can be especially true during an experiment or some other unusual exercise. Possible contributing factors to operational error include personnel fatigue, misunderstanding in communication, mistakes in executing orders, uncertainty about the delegated authority, pressure to meet a demanding schedule, and a lack of understanding of the possible consequences of deliberate violations of the facility's established operating procedures. Authoritative reports indicate that most of these factors were involved in the disastrous Russian Chernobyl-4 nuclear reactor accident in April 1986, which, ironically, occurred when a safety experiment was being conducted. Given the computer hardware and software now available for implementing expert systems together with integrated signal monitoring and communications, plant protection could be enhanced by an expert system with extended features to monitor the plant. The system could require information from the operators on a rigidly enforced schedule and automatically log in and report on a scheduled time basis to authorities at a central remote site during periods of safe operation. Additionally, the system could warn an operator or automatically shut down the plant in case of dangerous conditions, while simultaneously notifying independent, responsible, off-site personnel of the action taken. This approach would provide protection beyond that provided by typical facility scram circuits. This paper presents such an approach to implementing an expert system for plant protection, together with specific hardware and software configurations. The Chernobyl accident is used as the basis of discussion

  8. The new FTU continuous monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Bertocchi, A [Euratom-ENEA Association, Frascati Research Center, Via E. Fermi 45, 00044 Frascati (Rome) (Italy); Podda, S [Euratom-ENEA Association, Frascati Research Center, Via E. Fermi 45, 00044 Frascati (Rome) (Italy); Vitale, V [Euratom-ENEA Association, Frascati Research Center, Via E. Fermi 45, 00044 Frascati (Rome) (Italy)

    2005-11-15

    The Frascati Tokamak Upgrade (FTU) continuous (slow) data acquisition system has been redesigned to allow easy monitoring of the status of the plant. In the new system 'Opto22(TM)' modules, which use Ethernet as fieldbus, substitute the old 'programmable logic controller (PLC)' devices allowing easy access to and display of many continuous measurements. Data collected by 'Opto22' modules are stored in a 'MySQL' database via a driver written in C++ language. A 'CORBA' server, running on the same machine hosting the 'MySQL' server, allows the database access from any remote client regardless of the local platform. A remarkable aspect looks out for the use of totally free software packages. This new architecture overcomes the limitations of the previous monitoring system:*an interface based on internet browser allows to easily configure Opto22 modules and MySQL database; a graphical interface, developed in Java, allows data management and visualization; the above operations are completely platform independent. In addition the CORBA server introduces the advantages of:hardware independence, thus allowing maximum flexibility in the choice of platforms and system components; both network and programming languages being completely transparent. This paper will present the new system architecture, last results and future developments.

  9. The new FTU continuous monitoring system

    International Nuclear Information System (INIS)

    Bertocchi, A.; Podda, S.; Vitale, V.

    2005-01-01

    The Frascati Tokamak Upgrade (FTU) continuous (slow) data acquisition system has been redesigned to allow easy monitoring of the status of the plant. In the new system 'Opto22(TM)' modules, which use Ethernet as fieldbus, substitute the old 'programmable logic controller (PLC)' devices allowing easy access to and display of many continuous measurements. Data collected by 'Opto22' modules are stored in a 'MySQL' database via a driver written in C++ language. A 'CORBA' server, running on the same machine hosting the 'MySQL' server, allows the database access from any remote client regardless of the local platform. A remarkable aspect looks out for the use of totally free software packages. This new architecture overcomes the limitations of the previous monitoring system:*an interface based on internet browser allows to easily configure Opto22 modules and MySQL database; a graphical interface, developed in Java, allows data management and visualization; the above operations are completely platform independent. In addition the CORBA server introduces the advantages of:hardware independence, thus allowing maximum flexibility in the choice of platforms and system components; both network and programming languages being completely transparent. This paper will present the new system architecture, last results and future developments

  10. Master Console System Monitoring and Control Development

    Science.gov (United States)

    Brooks, Russell A.

    2013-01-01

    The Master Console internship during the summer of 2013 involved the development of firing room displays and support applications at the John F. Kennedy Space Center (KSC). This position was with the Master Console Product Group (MCPG) on the Launch Control System (LCS) project. This project is responsible for the System Monitoring and Control (SMC) and Record and Retrieval (R&R) of launch operations data. The Master Console is responsible for: loading the correct software into each of the remaining consoles in the firing room, connecting the proper data paths to and from the launch vehicle and all ground support equipment, and initializing the entire firing room system to begin processing. During my internship, I created control scripts using the Application Control Language (ACL) to analyze the health and status of Kennedy Ground Control System (KGCS) programmable logic controllers (PLCs). This application provides a system health and status display I created with summarized data for use by Master Console Operators (MCO) to monitor and verify the integrity of KGCS subsystems.

  11. Nutrient Film Technique (NFT Hydroponic Monitoring System

    Directory of Open Access Journals (Sweden)

    Helmy Helmy

    2016-10-01

    Full Text Available Plant cultivation using hydroponic is very popular today. Nutrient Film Technique (NFT hydroponic system is commonly used by people. It can be applied indoor or outdoor. Plants in this systemneed nutrient solution to grow well. pH, TDS and temperature of the nutrient solution must be check to ensure plant gets sufficient nutrients. This research aims todevelop monitoring system of NFT hydroponic. Farmer will be able to monitor pH, TDS and temperature online. It will ease farmer to decide which plant is suitable to be cultivated and time to boost growth.Delay of the system will be measured to know system performance. Result shows that pH is directly proportional with TDS. Temperature value has no correlation with pH and TDS. System has highest delay during daylight and afternoon but it will decline in the night and morning. Average of delay in the morning is 11 s, 28.5 s in daylight, 32 s in the afternoon and 17.5 s in the night.

  12. Preventing the first cesarean delivery: summary of a joint Eunice Kennedy Shriver National Institute of Child Health and Human Development, Society for Maternal-Fetal Medicine, and American College of Obstetricians and Gynecologists Workshop.

    Science.gov (United States)

    Spong, Catherine Y; Berghella, Vincenzo; Wenstrom, Katharine D; Mercer, Brian M; Saade, George R

    2012-11-01

    With more than one third of pregnancies in the United States being delivered by cesarean and the growing knowledge of morbidities associated with repeat cesarean deliveries, the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the Society for Maternal-Fetal Medicine, and the American College of Obstetricians and Gynecologists convened a workshop to address the concept of preventing the first cesarean delivery. The available information on maternal and fetal factors, labor management and induction, and nonmedical factors leading to the first cesarean delivery was reviewed as well as the implications of the first cesarean delivery on future reproductive health. Key points were identified to assist with reduction in cesarean delivery rates including that labor induction should be performed primarily for medical indication; if done for nonmedical indications, the gestational age should be at least 39 weeks or more and the cervix should be favorable, especially in the nulliparous patient. Review of the current literature demonstrates the importance of adhering to appropriate definitions for failed induction and arrest of labor progress. The diagnosis of "failed induction" should only be made after an adequate attempt. Adequate time for normal latent and active phases of the first stage, and for the second stage, should be allowed as long as the maternal and fetal conditions permit. The adequate time for each of these stages appears to be longer than traditionally estimated. Operative vaginal delivery is an acceptable birth method when indicated and can safely prevent cesarean delivery. Given the progressively declining use, it is critical that training and experience in operative vaginal delivery are facilitated and encouraged. When discussing the first cesarean delivery with a patient, counseling should include its effect on future reproductive health.

  13. Preventing the First Cesarean Delivery: Summary of a Joint Eunice Kennedy Shriver National Institute of Child Health and Human Development, Society for Maternal-Fetal Medicine, and American College of Obstetricians and Gynecologists Workshop

    Science.gov (United States)

    Spong, Catherine Y.; Berghella, Vincenzo; Wenstrom, Katharine D.; Mercer, Brian M.; Saade, George R.

    2012-01-01

    With over one-third of pregnancies in the United States being delivered by cesarean and the growing knowledge of morbidities associated with repeat cesarean deliveries, the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the Society for Maternal-Fetal Medicine, and the American College of Obstetricians and Gynecologists convened a workshop to address the concept of preventing the first cesarean. The available information on maternal and fetal factors, labor management and induction, and non-medical factors leading to the first cesarean were reviewed as well as the implications of the first cesarean on future reproductive health. Key points were identified to assist with reduction in cesarean rates including that labor induction should be performed primarily for medical indication; if done for non-medical indications, the gestational age should be at least 39 weeks or more and the cervix should be favorable, especially in the nulliparous patient. Review of the current literature demonstrates the importance of adhering to appropriate definitions for failed induction and arrest of labor progress. The diagnosis of “failed induction” should only be made after an adequate attempt. Adequate time for normal latent and active phases of the first stage, and for the second stage, should be allowed, as long as the maternal and fetal conditions permit. The adequate time for each of these stages appears to be longer than traditionally estimated. Operative vaginal delivery is an acceptable birth method when indicated, and can safely prevent cesarean delivery. Given the progressively declining use, it is critical that training and experience in operative vaginal delivery is facilitated and encouraged. When discussing the first cesarean with a patient, counseling should include its effect on future reproductive health. PMID:23090537

  14. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  15. A radiation monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.

    1974-01-01

    Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)

  16. The adaptive safety analysis and monitoring system

    Science.gov (United States)

    Tu, Haiying; Allanach, Jeffrey; Singh, Satnam; Pattipati, Krishna R.; Willett, Peter

    2004-09-01

    The Adaptive Safety Analysis and Monitoring (ASAM) system is a hybrid model-based software tool for assisting intelligence analysts to identify terrorist threats, to predict possible evolution of the terrorist activities, and to suggest strategies for countering terrorism. The ASAM system provides a distributed processing structure for gathering, sharing, understanding, and using information to assess and predict terrorist network states. In combination with counter-terrorist network models, it can also suggest feasible actions to inhibit potential terrorist threats. In this paper, we will introduce the architecture of the ASAM system, and discuss the hybrid modeling approach embedded in it, viz., Hidden Markov Models (HMMs) to detect and provide soft evidence on the states of terrorist network nodes based on partial and imperfect observations, and Bayesian networks (BNs) to integrate soft evidence from multiple HMMs. The functionality of the ASAM system is illustrated by way of application to the Indian Airlines Hijacking, as modeled from open sources.

  17. Development of the real time monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Katsumi [Research Organization for Information Science and Technology, Tokai, Ibaraki (Japan); Watanabe, Tadashi; Kaburaki, Hideo

    1996-10-01

    Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering (CCSE) for the computational science research in nuclear fields. Visualization and animation processing technique are studied and developed for efficient understanding of simulation results. The real time monitor system, in which on-going simulation results are transferred from a supercomputer or workstation to a graphic workstation and are visualized and recorded, is described in this report. This system is composed of the graphic workstation and the video equipment connected to the network. The control shell programs are the job-execution shell for simulations on supercomputers, the file-transfer shell for output files for visualization, and the shell for starting visualization tools. Special image processing technique and hardware are not necessary in this system and the standard visualization tool AVS and the UNIX commands are used, so that this system can be implemented and applied in various computer environments. (author)

  18. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  19. Development of the Guardian environmental monitoring system

    International Nuclear Information System (INIS)

    Gould, J.L.; Thompson, I.M.G.

    1982-01-01

    The report describes the Guardian Environmental Monitoring System, developed jointly by the CEGB's Berkeley Nuclear Laboratories (BNL) and GEC Energy Systems Limited (ESL). The basic battery operated instrument was developed by BNL for the measurement of any nuclear facility contribution to the overall environmental dose. It uses an energy compensated Geiger counter to provide a continuous record for over a month of dose rates from 1 μR h -1 (10nGy h -1 ). Results are presented of initial development trials and of an intercomparison with the USA Environmental Measurement Laboratory. The Guardian system, however, was developed, not only to meet the CEGB requirements for a recording monitor, but also to meet the requirements of US Regulatory Commission Guide RG 1.97, introduced as a result of the accident at Three Mile Island. This system, by using two energy compensated Geiger counters has a range from 1μRh -1 up to 10Rh -1 (approximately equal to 100mGyh -1 ), and the associated electronics provides automatic range changing, including fast response to ramp exposure rate changes, alarm and test facilities and telemetry by line or radio to a central station. (author)

  20. Monitoring System For Improving Radiation Safety Management

    International Nuclear Information System (INIS)

    Osovizky, A.; Paran, J.; Tal, N.; Ankry, N.; Ashkenazi, B.; Tirosh, D.; Marziano, R.; Chisin, R.

    1999-01-01

    Medi SMARTS (Medical Survey Mapping Automatic Radiation Tracing System), a gamma radiation monitoring system, was installed in a nuclear medicine department. In this paper the evaluation of the system's ability to improve radiation safety management is presented. The system is based on a state of the art software that continuously collects on line radiation measurements for display, analysis and logging. Radiation is measured by GM tubes; the signal is transferred to a data processing unit and then via an RS-485 communication line to a computer. The system automatically identifies the detector type and its calibration factor, thus providing compatibility, maintainability and versatility when changing detectors. Radiation levels are displayed on the nuclear medicine department map at six locations. The system has been operating continuously for more than one year, documenting abnormal events caused by routine operation or failure incidents. In cases where abnormal working conditions were encountered, an alarm message was sent automatically to the supervisor via his tele-pager. An interesting issue observed during the system evaluation, was the inability to distinguish between high radiation levels caused by proper routine operation and those caused by safety failure incidents. The solution included examination of two parameters, radiation levels as well as their duration period. A careful analysis of the historical data, applying the appropriated combined parameters determined for each location, verified that such a system can identify abnormal events, provide alarms to warn in case of incidents and improve standard operating procedures

  1. Smart Garbage Monitoring System for Waste Management

    Directory of Open Access Journals (Sweden)

    Mohd Yusof Norfadzlia

    2017-01-01

    Full Text Available Piles of rubbish are one of the major problems faced by most people in Malaysia, especially those who live in flats, as the number of bins is limited and shared among all residents. It may cause pollutions, which may lead to sanitary issues and diseases. This project presents the development of a smart garbage monitoring system in order to measure waste level in the garbage bin in real-time and to alert the municipality, in particular cases, via SMS. The proposed system is consisted by the ultrasonic sensor to measure the waste level, the GSM module to send the SMS, and an Arduino Uno which controls the system operation. It supposes to generate and send the warning messages to the municipality via SMS when the waste bin is full or almost full, so the garbage can be collected immediately. Furthermore, it is expected to contribute to improving the efficiency of the solid waste disposal management.

  2. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface......, and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program...

  3. An empirical, integrated forest biomass monitoring system

    Science.gov (United States)

    Kennedy, Robert E.; Ohmann, Janet; Gregory, Matt; Roberts, Heather; Yang, Zhiqiang; Bell, David M.; Kane, Van; Hughes, M. Joseph; Cohen, Warren B.; Powell, Scott; Neeti, Neeti; Larrue, Tara; Hooper, Sam; Kane, Jonathan; Miller, David L.; Perkins, James; Braaten, Justin; Seidl, Rupert

    2018-02-01

    The fate of live forest biomass is largely controlled by growth and disturbance processes, both natural and anthropogenic. Thus, biomass monitoring strategies must characterize both the biomass of the forests at a given point in time and the dynamic processes that change it. Here, we describe and test an empirical monitoring system designed to meet those needs. Our system uses a mix of field data, statistical modeling, remotely-sensed time-series imagery, and small-footprint lidar data to build and evaluate maps of forest biomass. It ascribes biomass change to specific change agents, and attempts to capture the impact of uncertainty in methodology. We find that: • A common image framework for biomass estimation and for change detection allows for consistent comparison of both state and change processes controlling biomass dynamics. • Regional estimates of total biomass agree well with those from plot data alone. • The system tracks biomass densities up to 450-500 Mg ha-1 with little bias, but begins underestimating true biomass as densities increase further. • Scale considerations are important. Estimates at the 30 m grain size are noisy, but agreement at broad scales is good. Further investigation to determine the appropriate scales is underway. • Uncertainty from methodological choices is evident, but much smaller than uncertainty based on choice of allometric equation used to estimate biomass from tree data. • In this forest-dominated study area, growth and loss processes largely balance in most years, with loss processes dominated by human removal through harvest. In years with substantial fire activity, however, overall biomass loss greatly outpaces growth. Taken together, our methods represent a unique combination of elements foundational to an operational landscape-scale forest biomass monitoring program.

  4. Monitoring the LHCb data quality system

    CERN Multimedia

    Baranov, Alexander

    2016-01-01

    Monitoring the quality of the data, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the apparatus during the data taking. DQM at LHCb is carried out in two phase. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs with some delay. For the Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator's task, Monet is also equipped with an automated, fully configurable, alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation.

  5. Prometheus: a next-generation monitoring system

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Prometheus is an open eco-system that provides an end-to-end approach to infrastructure and application monitoring. It covers all levels beginning with easy instrumentation based on a flexible, multi-dimensional data model. The Prometheus server itself collects and stores time series while trying to maintain operational simplicity while being adaptable to varying scales and layouts of infrastructure. By integrating with a wide range of service discovery systems, it always stays in sync with the world it is monitoring. The powerful query language allows us to ask complex questions and can be applied seamlessly between ad-hoc investigation and static dashboarding. It is also directly applied in the eco-system's alerting layer, which favors a time-series based over and event driven approach. In this talk we will look at all aspects of Prometheus from the high-level philosophy behind its design to its practical concerns of implementation and operation. About the speaker Fabian Reinartz is a software eng...

  6. Monitored Retrievable Storage System Requirements Document

    International Nuclear Information System (INIS)

    1994-03-01

    This Monitored Retrievable Storage System Requirements Document (MRS-SRD) describes the functions to be performed and technical requirements for a Monitored Retrievable Storage (MRS) facility subelement and the On-Site Transfer and Storage (OSTS) subelement. The MRS facility subelement provides for temporary storage, at a Civilian Radioactive Waste Management System (CRWMS) operated site, of spent nuclear fuel (SNF) contained in an NRC-approved Multi-Purpose Canister (MPC) storage mode, or other NRC-approved storage modes. The OSTS subelement provides for transfer and storage, at Purchaser sites, of spent nuclear fuel (SNF) contained in MPCs. Both the MRS facility subelement and the OSTS subelement are in support of the CRWMS. The purpose of the MRS-SRD is to define the top-level requirements for the development of the MRS facility and the OSTS. These requirements include design, operation, and decommissioning requirements to the extent they impact on the physical development of the MRS facility and the OSTS. The document also presents an overall description of the MRS facility and the OSTS, their functions (derived by extending the functional analysis documented by the Physical System Requirements (PSR) Store Waste Document), their segments, and the requirements allocated to the segments. In addition, the top-level interface requirements of the MRS facility and the OSTS are included. As such, the MRS-SRD provides the technical baseline for the MRS Safety Analysis Report (SAR) design and the OSTS Safety Analysis Report design

  7. Automatic outdoor monitoring system for photovoltaic panels.

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  8. Automatic outdoor monitoring system for photovoltaic panels

    Energy Technology Data Exchange (ETDEWEB)

    Stefancich, Marco [Consiglio Nazionale delle Ricerce, Istituto dei Materiali per l’Elettronica ed il Magnetismo (CNR-IMEM), Parco Area delle Scienze 37/A, 43124 Parma, Italy; Simpson, Lin [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA; Chiesa, Matteo [Masdar Institute of Science and Technology, P.O. Box 54224, Masdar City, Abu Dhabi, United Arab Emirates

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  9. ATLAS Tile calorimeter calibration and monitoring systems

    Science.gov (United States)

    Chomont, Arthur; ATLAS Collaboration

    2017-11-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises cesium radioactive sources, Laser and charge injection elements, and allows for monitoring and equalization of the calorimeter response at each stage of the signal production, from scintillation light to digitization. Based on LHC Run 1 experience, several calibration systems were improved for Run 2. The lessons learned, the modifications, and the current LHC Run 2 performance are discussed.

  10. Best Management Practices Monitoring Guide for Stream Systems

    OpenAIRE

    Mesner, Nancy

    2011-01-01

    Best Management Practices Monitoring Guide for Stream Systems provides guidance on establishing a water quality monitoring program that will demonstrate the effectiveness of Best Management Practices (BMPs) to reduce nonpoint source pollution in stream systems.

  11. Inherently safe passive gas monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Cordaro, Joseph V.; Bellamy, John Stephen; Shuler, James M.; Shull, Davis J.; Leduc, Daniel R.

    2016-09-06

    Generally, the present disclosure is directed to gas monitoring systems that use inductive power transfer to safely power an electrically passive device included within a nuclear material storage container. In particular, the electrically passive device can include an inductive power receiver for receiving inductive power transfer through a wall of the nuclear material storage container. The power received by the inductive power receiver can be used to power one or more sensors included in the device. Thus, the device is not required to include active power generation components such as, for example, a battery, that increase the risk of a spark igniting flammable gases within the container.

  12. Underwater Animal Monitoring Magnetic Sensor System

    KAUST Repository

    Kaidarova, Altynay

    2017-10-01

    Obtaining new insights into the behavior of free-living marine organisms is fundamental for conservation efforts and anticipating the impact of climate change on marine ecosystems. Despite the recent advances in biotelemetry, collecting physiological and behavioral parameters of underwater free-living animals remains technically challenging. In this thesis, we develop the first magnetic underwater animal monitoring system that utilizes Tunnel magnetoresistance (TMR) sensors, the most sensitive solid-state sensors today, coupled with flexible magnetic composites. The TMR sensors are composed of CoFeB free layers and MgO tunnel barriers, patterned using standard optical lithography and ion milling procedures. The short and long-term stability of the TMR sensors has been studied using statistical and Allan deviation analysis. Instrumentation noise has been reduced using optimized electrical interconnection schemes. We also develop flexible NdFeB-PDMS composite magnets optimized for applications in corrosive marine environments, and which can be attached to marine animals. The magnetic and mechanical properties are studied for different NdFeB powder concentrations and the performance of the magnetic composites for different exposure times to sea water is systematically investigated. Without protective layer, the composite magnets loose more than 50% of their magnetization after 51 days in seawater. The durability of the composite magnets can be considerably improved by using polymer coatings which are protecting the composite magnet, whereby Parylene C is found to be the most effective solution, providing simultaneously corrosion resistance, flexibility, and enhanced biocompatibility. A Parylene C film of 2μm thickness provides the sufficient protection of the magnetic composite in corrosive aqueous environments for more than 70 days. For the high level performance of the system, the theoretically optimal position of the composite magnets with respect to the sensing

  13. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  14. airborne data analysis/monitor system

    Science.gov (United States)

    Stephison, D. B.

    1981-01-01

    An Airborne Data Analysis/Monitor System (ADAMS), a ROLM 1666 computer based system installed onboard test airplanes used during experimental testing is evaluated. In addition to the 1666 computer, the ADAMS hardware includes a DDC System 90 fixed head disk and a Miltape DD400 floppy disk. Boeing designed a DMA interface to the data acquisition system and an intelligent terminal to reduce system overhead and simplify operator commands. The ADAMS software includes RMX/RTOS and both ROLM FORTRAN and assembly language are used. The ADAMS provides real time displays that enable onboard test engineers to make rapid decisions about test conduct thus reducing the cost and time required to certify new model airplanes, and improved the quality of data derived from the test, leading to more rapid development of improvements resulting in quieter, safer, and more efficient airplanes. The availability of airborne data processing removes most of the weather and geographical restrictions imposed by telemetered flight test data systems. A data base is maintained to describe the airplane, the data acquisition system, the type of testing, and the conditions under which the test is performed.

  15. Minicomputer controlled test system for process control and monitoring systems

    International Nuclear Information System (INIS)

    Worster, L.D.

    A minicomputer controlled test system for testing process control and monitoring systems is described. This system, in service for over one year, has demonstrated that computerized control of such testing has a real potential for expanding the scope of the testing, improving accuracy of testing, and significantly reducing the time required to do the testing. The test system is built around a 16-bit minicomputer with 12K of memory. The system programming language is BASIC with the addition of assembly level routines for communication with the peripheral devices. The peripheral devices include a 100 channel scanner, analog-to-digital converter, visual display, and strip printer. (auth)

  16. Monitoring and operation system for severe accidents

    International Nuclear Information System (INIS)

    Fukui, Toshiki; Niida, Shinji; Kato, Yumeto

    2017-01-01

    Monitoring and operation system for Severe Accidents (SA-MOS) is a compact Instrumentation and Control (I and C) system developed by Mitsubishi Heavy Industries (MHI) and certificated by the Japanese Nuclear Regulatory Agency (NRA) as a design application for Japanese existing PWR nuclear power plants. The system is tailored to provide monitoring and operation for Severe Accident (SA) conditions, and consists of digitalized I and C System, Human Systems Interface (HSI) system and Power Supply (PS) system as further improvement of reliability and safety. This design plans to be applied to the next Japanese PWR plants. In accordance with the new regulatory standards that NRA has established corresponding to the Fukushima accident, a long-term Station Black Out (SBO) scenario and 24-hours power supply by the storage battery in case of SA has been required. In order to address 24-hours power supply requirement in SA condition, the storage battery volume shall be increased. However, it may be difficult to introduce additional batteries to the existing plant site because of room space constraints, etc. Therefore, power distributions for the facilities which are only used for Design Basis Accident (DBA), are shut down in order to secure 24-hours operations of facilities for SA conditions including SA-MOS. That enables efficient battery resource operations as well as optimizes room space factors shared by battery cabinets. Another benefit is to introduce dedicate HSI system for SA condition and operators shift their operations using that dedicated HSI system to cope with SA events. That can reduce operator workload which forces operators to verify or choose which controllers and indicators are available in SA conditions. Furthermore, application of SA-MOS, secures the independence of the layers (DBA⇔SA) as well as secures the plant data transfer for SA conditions outside of plant. Those plant data assets can be shared by plant operation supporting personnel and

  17. Propose Reactor Control and Monitoring System for RTP

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Izhar Abu Hussin; Mohd Idris Taib; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha

    2011-01-01

    Reactor control and monitoring system is a one of the important features used in reactor. The control and monitoring must come together to provide safety, excellent performance and reliable in nuclear reactor technology application. Objectives of this technical paper are to design and propose reactor control system and reactor monitoring system in Research Reactor (RTP) for Reactor Upgrading Project. (author)

  18. Alignment performance monitoring for ASML systems

    Science.gov (United States)

    Chung, Woong-Jae; Temchenko, Vlad; Hauck, Tarja; Schmidt, Sebastian

    2006-03-01

    In today's semiconductor industry downscaling of the IC design puts a stringent requirement on pattern overlay control. Tighter overlay requirements lead to exceedingly higher rework rates, meaning additional costs to manufacturing. Better alignment control became a target of engineering efforts to decrease rework rate for high-end technologies. Overlay performance is influenced by known parameters such as "Shift, Scaling, Rotation, etc", and unknown parameters defined as "Process Induced Variation", which are difficult to control by means of a process automation system. In reality, this process-induced variation leads to a strong wafer to wafer, or lot to lot variation, which are not easy to detect in the mass-production environment which uses sampling overlay measurements for only several wafers in a lot. An engineering task of finding and correcting a root cause for Process Induced Variations of overlay performance will be greatly simplified if the unknown parameters could be tracked for each wafer. This paper introduces an alignment performance monitoring method based on analysis of automatically generated "AWE" files for ASML scanner systems. Because "AWE" files include alignment results for each aligned wafer, it is possible to use them for monitoring, controlling and correcting the causes of "process induced" overlay performance without requiring extra measurement time. Since "AWE" files include alignment information for different alignment marks, it is also possible to select and optimize the best alignment recipe for each alignment strategy. Several case studies provided in our paper will demonstrate how AWE file analysis can be used to assist engineer in interpreting pattern alignment data. Since implementing our alignment data monitoring method, we were able to achieve significant improvement of alignment and overlay performance without additional overlay measurement time. We also noticed that the rework rate coming from alignment went down and

  19. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  20. RHIC Beam Loss Monitor System Initial Operation

    International Nuclear Information System (INIS)

    Witkover, R. L.; Michnoff, R. J.; Geller, J. M.

    1999-01-01

    The RHIC Beam Loss Monitor (BLM) System is designed to prevent beam loss quenching of the superconducting magnets, and acquire loss data. Four hundred ion chambers are located around the rings to detect losses. The required 8-decade range in signal current is compressed using an RC pre-integrator ahead of a low current amplifier. A beam abort may be triggered if fast or slow losses exceed programmable threshold levels. A micro-controller based VME module sets references and gains and reads trip status for up to 64 channels. Results obtained with the detectors in the RHIC Sextant Test and the prototype electronics in the AGS-to-RHIC (AtR) transfer line are presented along with the present status of the system

  1. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Boumediene, Djamel Eddine; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). PMT signals are then digitized at 40 MHz and stored on detector and are only transferred off detector once the first level trigger acceptance has been confirmed. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator b...

  2. Airborne systems for emergency radiological monitoring

    International Nuclear Information System (INIS)

    Jupiter, C.; Boyns, P.

    1976-01-01

    A variety of aerial radiological monitoring systems are available to respond to a radiological accident or incident affecting large areas. These are operated by EG and G, Inc. for ERDA's Division of Operational Safety. A survey system can be airborne within approximately two hours after notification. Both airborne and terrestrial radioactivity can be measured and mapped. Special analysis procedures allow discrimination between radioactivity from most man-made radioelements and naturally occurring radioelements. A position accuracy of +-54 feet can be maintained over a large area survey. Detection sensitivity for gamma sources employing NaI detector arrays on board an airplane flying at 500 feet altitude is better than 2 μR/hr for surface planar contaminants and approximately 10 mCi for a point gamma source

  3. The Automator: Intelligent control system monitoring

    International Nuclear Information System (INIS)

    M. Bickley; D.A. Bryan; K.S. White

    1999-01-01

    A large-scale control system may contain several hundred thousand control points which must be monitored to ensure smooth operation. Knowledge of the current state of such a system is often implicit in the values of these points and operators must be cognizant of the state while making decisions. Repetitive operators requiring human intervention lead to fatigue, which can in turn lead to mistakes. The authors propose a tool called the Automator based on a middleware software server. This tool would provide a user-configurable engine for monitoring control points. Based on the status of these control points, a specified action could be taken. The action could range from setting another control point, to triggering an alarm, to running an executable. Often the data presented by a system is meaningless without context information from other channels. Such a tool could be configured to present interpreted information based on values of other channels. Additionally, this tool could translate numerous values in a non-friendly form (such as numbers, bits, or return codes) into meaningful strings of information. Multiple instances of this server could be run, allowing individuals or groups to configure their own Automators. The configuration of the tool will be file-based. In the future, these files could be generated by graphical design tools, allowing for rapid development of new configurations. In addition, the server will be able to explicitly maintain information about the state of the control system. This state information can be used in decision-making processes and shared with other applications. A conceptual framework and software design for the tool are presented

  4. Safety performance monitoring of autonomous marine systems

    International Nuclear Information System (INIS)

    Thieme, Christoph A.; Utne, Ingrid B.

    2017-01-01

    The marine environment is vast, harsh, and challenging. Unanticipated faults and events might lead to loss of vessels, transported goods, collected scientific data, and business reputation. Hence, systems have to be in place that monitor the safety performance of operation and indicate if it drifts into an intolerable safety level. This article proposes a process for developing safety indicators for the operation of autonomous marine systems (AMS). The condition of safety barriers and resilience engineering form the basis for the development of safety indicators, synthesizing and further adjusting the dual assurance and the resilience based early warning indicator (REWI) approaches. The article locates the process for developing safety indicators in the system life cycle emphasizing a timely implementation of the safety indicators. The resulting safety indicators reflect safety in AMS operation and can assist in planning of operations, in daily operational decision-making, and identification of improvements. Operation of an autonomous underwater vehicle (AUV) exemplifies the process for developing safety indicators and their implementation. The case study shows that the proposed process leads to a comprehensive set of safety indicators. It is expected that application of the resulting safety indicators consequently will contribute to safer operation of current and future AMS. - Highlights: • Process for developing safety indicators for autonomous marine systems. • Safety indicators based on safety barriers and resilience thinking. • Location of the development process in the system lifecycle. • Case study on AUV demonstrating applicability of the process.

  5. Indirect Tire Monitoring System - Machine Learning Approach

    Science.gov (United States)

    Svensson, O.; Thelin, S.; Byttner, S.; Fan, Y.

    2017-10-01

    The heavy vehicle industry has today no requirement to provide a tire pressure monitoring system by law. This has created issues surrounding unknown tire pressure and thread depth during active service. There is also no standardization for these kind of systems which means that different manufacturers and third party solutions work after their own principles and it can be hard to know what works for a given vehicle type. The objective is to create an indirect tire monitoring system that can generalize a method that detect both incorrect tire pressure and thread depth for different type of vehicles within a fleet without the need for additional physical sensors or vehicle specific parameters. The existing sensors that are connected communicate through CAN and are interpreted by the Drivec Bridge hardware that exist in the fleet. By using supervised machine learning a classifier was created for each axle where the main focus was the front axle which had the most issues. The classifier will classify the vehicles tires condition and will be implemented in Drivecs cloud service where it will receive its data. The resulting classifier is a random forest implemented in Python. The result from the front axle with a data set consisting of 9767 samples of buses with correct tire condition and 1909 samples of buses with incorrect tire condition it has an accuracy of 90.54% (0.96%). The data sets are created from 34 unique measurements from buses between January and May 2017. This classifier has been exported and is used inside a Node.js module created for Drivecs cloud service which is the result of the whole implementation. The developed solution is called Indirect Tire Monitoring System (ITMS) and is seen as a process. This process will predict bad classes in the cloud which will lead to warnings. The warnings are defined as incidents. They contain only the information needed and the bandwidth of the incidents are also controlled so incidents are created within an

  6. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing.......We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  7. Timing and control monitor system upgrade design document. Version 4

    International Nuclear Information System (INIS)

    Brandt, J.J.

    1984-01-01

    This is a design document for the Timing and Control Monitor System Upgrade Project. This project is intended to provide a replacement system for the existing user Encoder Monitor Systems and Varian 72 Control Room computer systems. All of these systems reside at the Nevada Test Site. The function of the T and C Monitor System is to gather real-time statistics and data on user defined key variables from control, communication, data acquistion systems, and from the monitoring system itself. The control, communication, and data acquisition systems each operate separately from the monitor system. The T and C Monitor System gathers this data in order to verify the readiness of an event to begin countdown. This includes setup, verification, calibration, and peripheral services, report any failures that may occur during the countdown, verify detonation and containment, and assist reentry activities after the event

  8. The arrangement of deformation monitoring project and analysis of monitoring data of a hydropower engineering safety monitoring system

    Science.gov (United States)

    Wang, Wanshun; Chen, Zhuo; Li, Xiuwen

    2018-03-01

    The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.

  9. Ocean waves monitor system by inland microseisms

    Science.gov (United States)

    Lin, L. C.; Bouchette, F.; Chang, E. T. Y.

    2016-12-01

    Microseisms are continuous ground oscillations which have been wildly introduced for decades. It is well known that the microseismicity in the frequency band from 0.05 to about 1 Hz partly results from ocean waves, which has been first explained by Longuet-Higgins [1950]. The generation mechanism for such a microseismicity is based on nonlinear wave-wave interactions which drive pressure pulses within the seafloor. The resulting ground pressure fluctuations yield ground oscillations at a double frequency (DF) with respect to that of current ocean waves. In order to understand the characteristics of DF microseisms associated with different wave sources, we aim to analyze and interpret the spectra of DF microseisms by using the simple spectrum method [Rabinovich, 1997] at various inland seismometer along the Taiwan coast. This is the first monitoring system of ocean waves observed by inland seismometers in Taiwan. The method is applied to identify wave sources by estimating the spectral ratios of wave induced microseisms associated with local winds and typhoons to background spectra. Microseism amplitudes above 0.2 Hz show a good correlation with wind-driven waves near the coast. Comparison of microseism band between 0.1 and 0.2 Hz with buoys in the deep sea shows a strong correlation of seismic amplitude with storm generated waves, implying that such energy portion originates in remote regions. Results indicate that microseisms observed at inland sites can be a potential tool for the tracking of typhoon displacements and the monitoring of extreme ocean waves in real time. Real- time Microseism-Ocean Waves Monitoring Website (http://mwave.droppages.com/) Reference Rabinovich, A. B. (1997) "Spectral analysis of tsunami waves: Separation of source and topography effects," J. Geophys. Res., Vol. 102, p. 12,663-12,676. Longuet-Higgins, M.S. (1950) "A theory of origin of microseisms," Philos. Trans. R. Soc., A. 243, pp. 1-35.

  10. Seals monitoring systems using wireless communications

    International Nuclear Information System (INIS)

    Hermand, Guillaume; Bertrand, Johan; Farhoud, Radwan; Suzuki, Kei; ETO, Jiro; Tanabe, Hiromi; Takamura, Hisashi; Suyama, Yasuhiro

    2012-01-01

    Document available in extended abstract form only. Wireless monitoring based on electromagnetic waves is a promising application for deep geological nuclear waste repositories. It should allow data transmission without installing wires across the various seals (disposal cell plugs, gallery plugs, shaft plugs). Developments of the wireless system (e.g. transmitter and receiver) are in progress in order to fit the repository requirements. A common research program has been elaborated by RWMC and Andra. The present work aims at developing the wireless monitoring technology to intermediate level waste (ILW) disposal facilities concept. In this concept, ILW packages will be emplaced in disposal cells with concrete liner. After the operational phase, the cells will be backfilled with sealing material. In practice, this work demonstrates the feasibility of adapting and optimizing the wireless transmission system for specific repository cases. After preliminary transmission studies, it was decided to make a representative test in situ of a wireless transmission through the clay from a sealed side to an accessible side of the repository. In order to reduce the attenuation of magnetic flux caused by steel components between the transmitter and the receiver, the receiving antenna is installed in a dedicated borehole (drilled from the accessible side). Two types of reception antennas have been designed. According to its coil orientation, type A antenna measures the electromagnetic wave perpendicular to the borehole axis. On the other hand, type B antenna with a coil set in-line with the tubular casing, measures the electromagnetic wave parallel to the borehole axis. The outside cylinder (pressure tight case) is made of PVC considering the attenuation of electromagnetic flux. According to the direction of electromagnetic flux and position of the boreholes in the final repository design, type A or type B will be chosen. For the 'representative' test, a borehole, TSF1002 has been

  11. INFN-CNAF Monitor and Control System

    International Nuclear Information System (INIS)

    Antonelli, Stefano; De Girolamo, Donato; Dell'Agnello, Luca; Gregori, Daniele; Guizzunti, Guido; Ricci, Pier Paolo; Rosso, Felice; Sapunenko, Vladimir; Veraldi, Riccardo; Veronesi, Paolo; Vistoli, Cristina; Finzi, Giulia Vita; Zani, Stefano

    2011-01-01

    CNAF is the national center of National Institute of Nuclear Physics (INFN) for R and D in the field of Information Technologies applied to High Energy Physics (HEP) experiments. It is involved in the management and development of the most important information and data handling services in behalf of the INFN. In 2005, the Italian Tier-1 for Large Hadron Collider (LHC) experiments has been inaugurated at INFN-CNAF. Due to the huge complexity of Tier-1 center, the use of control systems is fundamental for management and operation of the center. At INFN-CNAF, several solutions have been adopted, from commercial to open source products up to entirely home-made systems. Adopted open source solutions have been strongly adapted to specific needs; a wide set of customized sensors has been developed for various divisions like Network, Storage, Farming, Grid operation and National Services. Finally, a dashboard has been developed, to which described control systems send critical alarms (sent via sms to an operator as well). The dashboard can be exploited to get an historical view of the Tier-1 and national services' state and to allow a quick web control. In this article, the whole system, adopted customizations in monitoring and control as well as their integrations with the dashboard will be described.

  12. Distributed monitoring system based on Icinga

    International Nuclear Information System (INIS)

    Haen, C.; Bonaccorsi, E.; Neufeld, N.

    2012-01-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure: it comprises more than 2000 servers and embedded systems and more than 200 network devices. Many of these equipment are critical in order to run the experiment, and it is important to have a monitoring solution efficient enough so that the experts can diagnose and act quickly. While our previous system was based on a central Nagios server, our current system uses a distributed Icinga infrastructure. We have a single instance of Icinga that schedules the checks and deals with the results but we have other servers (called 'workers') to perform the checks. The load induced on the worker is negligible, whereas the central server is fully busy. A client/server model based on Gearman manages queues the clients use to get their tasks and give their results. The other interesting feature of Icinga is the database back-end. Icinga will log the result of every action and check-result in a database. The new installation is now running 36000 service checks on 2100 hosts with 50 Gearman workers. Performances have dramatically improved

  13. A machine protection beam position monitor system

    International Nuclear Information System (INIS)

    Medvedko, E.; Smith, S.; Fisher, A.

    1998-01-01

    Loss of the stored beam in an uncontrolled manner can cause damage to the PEP-II B Factory. We describe here a device which detects large beam position excursions or unexpected beam loss and triggers the beam abort system to extract the stored beam safely. The bad-orbit abort trigger beam position monitor (BOAT BPM) generates a trigger when the beam orbit is far off the center (>20 mm), or rapid beam current loss (dI/dT) is detected. The BOAT BPM averages the input signal over one turn (136 kHz). AM demodulation is used to convert input signals at 476 MHz to baseband voltages. The detected signal goes to a filter section for suppression of the revolution frequency, then on to amplifiers, dividers, and comparators for position and current measurements and triggering. The derived current signal goes to a special filter, designed to perform dI/dT monitoring at fast, medium, and slow current loss rates. The BOAT BPM prototype test results confirm the design concepts. copyright 1998 American Institute of Physics

  14. Standard-D hydrogen monitoring system, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1996-01-01

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS

  15. Microquimerismo fetal-materno nas doenças reumáticas auto-imunes Maternal-fetal microchimerism in autoimmune rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Karin Spat Albino Barcellos

    2004-02-01

    Full Text Available Estudos recentes indicam a existência de um tráfego bidirecional de células durante a gestação humana normal. Células fetais persistem no sangue periférico materno por muitos anos após a gestação. Muitas doenças auto-imunes são mais prevalentes em mulheres, algumas das quais apresentam pico de incidência em fases tardias dos anos férteis femininos. A doença enxerto-versushospedeiro é uma condição conhecida de quimerismo e possui similaridades clínicas com algumas doenças auto-imunes reumáticas, notavelmente com esclerose sistêmica e síndrome de Sjögren e, algumas vezes, com lúpus eritematoso sistêmico. Este artigo explora a hipótese de que o microquimerismo fetal contribua para a patogênese de algumas doenças auto-imunes, baseado em revisões de estudos anteriores que trabalharam com esta hipótese. São apresentadas ressalvas de ordem conceitual e técnica a serem consideradas na interpretação dos dados da literatura.Recent studies indicate that there is bi-directional traffic of cells during normal human pregnancy. Fetal cells have been found to persist in the maternal peripheral blood for many years after pregnancy. Many autoimmune diseases are more prevalent in women, and some of them have peak incidence at late stages of childbearing years. Chronic graft versus host disease (cGVHD is a known condition of chimerism and has clinical similarities to some rheumatic autoimmune diseases, notably systemic sclerosis, Sjögren's syndrome and systemic lupus erythematosus. This article explores the hypothesis that fetal microchimerism contributes to the pathogenesis of some autoimmune diseases, based on reviews of previous studies that have worked with this hypothesis. Technical and conceptual considerations are presented for a critical appraisal of the available literature.

  16. Plant-wide integrated equipment monitoring and analysis system

    International Nuclear Information System (INIS)

    Morimoto, C.N.; Hunter, T.A.; Chiang, S.C.

    2004-01-01

    A nuclear power plant equipment monitoring system monitors plant equipment and reports deteriorating equipment conditions. The more advanced equipment monitoring systems can also provide information for understanding the symptoms and diagnosing the root cause of a problem. Maximizing the equipment availability and minimizing or eliminating consequential damages are the ultimate goals of equipment monitoring systems. GE Integrated Equipment Monitoring System (GEIEMS) is designed as an integrated intelligent monitoring and analysis system for plant-wide application for BWR plants. This approach reduces system maintenance efforts and equipment monitoring costs and provides information for integrated planning. This paper describes GEIEMS and how the current system is being upgraded to meet General Electric's vision for plant-wide decision support. (author)

  17. On-line process control monitoring system

    International Nuclear Information System (INIS)

    O'Rourke, P.E.; Van Hare, D.R.; Prather, W.S.

    1992-01-01

    This patent describes apparatus for monitoring at a plurality of locations within a system the concentration of at least one chemical substance involved in a chemical process. It comprises plurality of process cells; first means for carrying the light; second means for carrying the light; means for producing a spectrum from the light received by the second carrying means; multiplexing means for selecting one process cell of the plurality of process cells at a time so that the producing means can produce a process spectrum from the one cell of the process cells; a reference cell for producing a reference spectrum for comparison to the process spectrum; a standard cell for producing a standard spectrum for comparison to the process spectrum; and means for comparing the reference spectrum, the standard spectrum and the process spectrum and determining the concentration of the chemical substance in the process cell

  18. An integrate system for radioactivity monitoring

    International Nuclear Information System (INIS)

    Rusu, Al.; Bartos, D.; Constantin, F.; Stanga, D.; Giolu, Gh.; Calin, R.; Guta, T.; Stochioiu, A.; Lupu, A.

    2003-01-01

    This is one of the projects included in IFIN-HH nucleus programme 'Nuclear Physics Advanced Researches and Applied Nuclear Techniques'. A new instrument generation for measuring or monitoring the environmental radioactivity is to be developed, based on nowadays components, technology and data processing methods. The additional results should be: - the instrument and related procedures to certify the national standard for neutron dosimetry; - the operational simplicity and higher confidence in the new portable instruments for radioprotection; - the instruments and methods for gas absolute volume activity measuring laboratory; - transportable stand to measure the efficiency of the aerosol filtering systems; - PC based technique to reconstruct the radiometric map of an area supervised by an intelligent gamma probe array. The lecture is a review of the activities to be done. (authors)

  19. Rack Protection Monitor - A Simple System

    International Nuclear Information System (INIS)

    Orr, S.

    1997-12-01

    The Rack Protection Monitor is a simple, fail-safe device to monitor smoke, temperature and ventilation sensors. It accepts inputs from redundant sensors and has a hardwired algorithm to prevent nuisance power trips due to random sensor failures. When a sensor is triggered the Rack Protection Monitor latches and annunicates the alarm. If another sensor is triggered, the Rack Protection Monitor locally shuts down the power to the relay rack and sends alarm to central control

  20. A multifunction radioactive waste monitoring system

    International Nuclear Information System (INIS)

    Edeline, J.C.; Libs, G.

    1991-01-01

    The monitoring of unknown radioactive transuranic wastes mixed with fission products (FP) needs several measuring technics: passive and active neutron methods, gamma rays spectrometry and, sometimes, emission tomography to localize the hot points in the waste packages. The goal is to achieve a whole system from the most up-dated electronics sub-assemblies to provide these characterization measurement at the lowest cost and in the simplest manner. The control of the different measurements is made by only one micro-processor and an unusual way of using the gamma spectrometry A.D.C. and multichannel analyser makes possible to control the neutron analogic electronics: neutron counter high-voltage supplies, amplifiers and discriminators; many of the gamma spectrometry sub-assemblies are also used for the gamma emission tomography. The different measurements are automated and different programs offer the possibility to choice the proper measurement methods for each item. The waste package handling apparatus is not included in the system but the control of such handling might be performed by the micro-computer. We describe the main parts and features of the system [fr

  1. Monitoring System with Two Central Facilities Protocol

    Directory of Open Access Journals (Sweden)

    Caesar Firdaus

    2017-03-01

    Full Text Available The security of data and information on government’s information system required proper way of defending against threat. Security aspect can be achieved by using cryptography algorithm, applying information hiding concept, and implementing security protocol. In this research, two central facilities protocol was implemented on Research and Development Center of Mineral and Coal Technology’s Cooperation Contract Monitoring System by utilizing AES and whitespace manipulation algorithm. Adjustment on the protocol by creating several rule of validation ID’s generation and checking processes could fulfill two of four cryptography objectives, consist of authentication and non-repudiation. The solid collaboration between central legitimization agency (CLA, central tabulating facility (CTF, and client is the main idea in two central facilities protocol. The utilization of AES algorithm could defend the data on transmission from man in the middle attack scenario. On the other hand, whitespace manipulation algorithm provided data integrity aspect of the document that is uploaded to the system itself. Both of the algorithm fulfill confidentiality, data integrity, and authentication.

  2. NOKIA - nuclear power plant monitoring system

    International Nuclear Information System (INIS)

    Anon.

    The monitoring system is described developed specially for the LOVIISA-1 and -2 nuclear power plants with two WWER-440 units. The multiprocessor system of the WWER-440 contains 3 identical main computers. The in core instrumentation is based on stationary self-powered neutron detectors and on thermocouples for measuring the coolant temperature. The system has equipment for the automatic control of the insulation resistance of the self-powered detectors. It is also equipped with a wide range of standard and special programmes. The standard programmes permit the recording of analog and digital data at different frequencies depending on the pre-set requirements. These data are processed and form data files which are accessible from all programmes. The heart of the special programme is a code for the determination of the power distribution in the core of the WWER-440 reactor. The main part of the programme is the algorithm for computing measured neutron fluxes derived from the signals of the self-powered detectors and the algorithm for deriving the global distribution of the neutron flux in the core. The computed power distribution is used for the determination of instantaneous thermal loads and the distribution of burnup in the core. The production programme of the FINNATOM company for nuclear power plants is listed. (B.S.)

  3. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    Energy Technology Data Exchange (ETDEWEB)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P

    2006-09-15

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO{sub 2} into U-metal. For demonstration of this process, {alpha}-{gamma} type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for {gamma}-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  4. Air Quality System (AQS) Monitoring Network, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains points which depict air quality monitors within EPA's Air Quality System (AQS) monitoring network. This dataset is updated weekly to...

  5. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  6. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    International Nuclear Information System (INIS)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.

    2006-09-01

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for γ-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration

  7. The Creation of Differential Correction Systems and the Systems of Global Navigation Satellite System Monitoring

    National Research Council Canada - National Science Library

    Polishchuk, G. M; Kozlov, V. I; Urlichich, Y. M; Dvorkin, V. V; Gvozdev, V. V

    2002-01-01

    ... for the Russian Federation and a system of global navigation satellite system monitoring. These projects are some of the basic ones in the Federal program "Global Navigation System," aimed at maintenance and development of the GLONASS system...

  8. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  9. Liquid Effluent Monitoring Information System (LEMIS) System Construction

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The liquid effluent sampling program is part of the effort to minimize adverse environmental impact during the cleanup operation at the Hanford Site. Of the 33 Phase I and Phase II liquid effluents, all streams actively discharged to the soil column will be sampled. The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Construction document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  10. A New Environmental Monitoring System For Silkworm Incubators

    OpenAIRE

    Alejandra Duque-Torres; Juan Ruiz-Rosero; Gesille Zambrano-Gonzalez; Martha Almanza-Pinzon; Oscar Mauricio Caicedo Rendon; Gustavo Ramirez-Gonzalez

    2018-01-01

    A newly Monitoring Environmental Conditions System is proposed based on Raspberry-Pi. This proposal monitors the temperature, humidity, and luminosity in a silkworm incubator. The monitoring data are collected and save in the cloud for the subsequent analysis. The monitoring environmental system is based on Raspberry Pi due to capabilities, features, and low cost. The preliminary tests were realized in a real scenery and the results demonstrating its reliability.

  11. Diagnostic and monitoring systems in nuclear power plants

    International Nuclear Information System (INIS)

    Wehling, H.J.; Jax, P.; Streicher, V.

    1987-01-01

    Monitoring systems are important for the availability of nuclear power plants. A survey is given about such systems designed and constructed by the Kraftwerk Union AG Erlangen (Federal Republic of Germany) in order to assure the mechanical integrity of reactor cooling systems. Three monitoring systems based on microprocessors are presented: KUES (acoustic detection of loose parts), SUES (vibration), and FAMOS (fatigue)

  12. Wide-area, real-time monitoring and visualization system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  13. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  14. Tracer verification and monitoring of containment systems

    International Nuclear Information System (INIS)

    Lowry, W.; Dunn, S.D.; Williams, C.

    1996-01-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential for movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Consequently, barriers are primarily intended for use in high-risk sites where few viable alternatives exist to stop the movement of contaminants in the near term. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Existing surface-based and borehole geophysical techniques do not provide the degree of resolution required to assure the formation of an integral in-situ barrier. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) are developing a quantitative subsurface barrier assessment system using gaseous tracers. Called SEAtrace trademark, this system integrates an autonomous, multipoint soil vapor sampling and analysis system with a global optimization modeling methodology to pinpoint leak sources and sizes in real time. SEAtrace trademark is applicable to impermeable barrier emplacements above the water table, providing a conservative assessment of barrier integrity after emplacement, as well as a long term integrity monitoring function. The SEAtrace trademark system is being developed under funding by the DOE-EM Subsurface Contaminant Focus Area

  15. Current status of technology development on remote monitoring system

    International Nuclear Information System (INIS)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  16. RHIC beam loss monitor system design

    International Nuclear Information System (INIS)

    Witkover, R.; Zitvogel, E.; Michnoff, R.

    1997-01-01

    The Beam Loss Monitor (BLM) System is designed to prevent the quenching of RHIC magnets due to beam loss, provide quantitative loss data, and the loss history in the event of a beam abort. The system uses 400 ion chambers of a modified Tevatron design. To satisfy fast (single turn) and slow (100 msec) loss beam criteria and provide sensitivity for studies measurements, a range of over 8 decades is needed. An RC pre-integrator reduces the dynamic range for a low current amplifier. This is digitized for data logging. The output is also applied to an analog multiplier which compensates the energy dependence, extending the range of the abort comparators. High and low pass filters separate the signal to dual comparators with independent programmable trip levels. Up to 64 channels, on 8 VME boards, are controlled by a micro-controller based VME module, decoupling it from the front-end computer (FEC) for real-time operation. Results with the detectors in the RHIC Sextant Test and the electronics in the AGS-to-RHIC (AtR) transfer line will be presented

  17. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  18. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  19. Image acquisition system for traffic monitoring applications

    Science.gov (United States)

    Auty, Glen; Corke, Peter I.; Dunn, Paul; Jensen, Murray; Macintyre, Ian B.; Mills, Dennis C.; Nguyen, Hao; Simons, Ben

    1995-03-01

    An imaging system for monitoring traffic on multilane highways is discussed. The system, named Safe-T-Cam, is capable of operating 24 hours per day in all but extreme weather conditions and can capture still images of vehicles traveling up to 160 km/hr. Systems operating at different remote locations are networked to allow transmission of images and data to a control center. A remote site facility comprises a vehicle detection and classification module (VCDM), an image acquisition module (IAM) and a license plate recognition module (LPRM). The remote site is connected to the central site by an ISDN communications network. The remote site system is discussed in this paper. The VCDM consists of a video camera, a specialized exposure control unit to maintain consistent image characteristics, and a 'real-time' image processing system that processes 50 images per second. The VCDM can detect and classify vehicles (e.g. cars from trucks). The vehicle class is used to determine what data should be recorded. The VCDM uses a vehicle tracking technique to allow optimum triggering of the high resolution camera of the IAM. The IAM camera combines the features necessary to operate consistently in the harsh environment encountered when imaging a vehicle 'head-on' in both day and night conditions. The image clarity obtained is ideally suited for automatic location and recognition of the vehicle license plate. This paper discusses the camera geometry, sensor characteristics and the image processing methods which permit consistent vehicle segmentation from a cluttered background allowing object oriented pattern recognition to be used for vehicle classification. The image capture of high resolution images and the image characteristics required for the LPRMs automatic reading of vehicle license plates, is also discussed. The results of field tests presented demonstrate that the vision based Safe-T-Cam system, currently installed on open highways, is capable of producing automatic

  20. Online NPP monitoring with neuro-expert system

    International Nuclear Information System (INIS)

    Nabeshima, K.

    2002-01-01

    This study present a hybrid monitoring system for nuclear power plant utilizing neural networks and a rule-based expert system. The whole monitoring system including a data acquisition system and the advisory displays has been tested by an on-line simulator of pressurized water reactor. From the testing results, it was shown that the neural network in the monitoring system successfully modeled the plant dynamics and detected the symptoms of anomalies earlier than the conventional alarm system. The expert system also worked satisfactorily in diagnosing and displaying the system status by using the outputs of neural networks and a priori knowledge base

  1. Structure health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok

    2003-01-01

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  2. Structural health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)

    2003-07-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  3. Structure health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok [Smart Measurment Group. Korea Resarch Institute of Standards and Science, Saejeon (Korea, Republic of)

    2003-05-15

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  4. Structural health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok

    2003-01-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  5. Systems and method for lagrangian monitoring of flooding conditions

    KAUST Repository

    Claudel, Christian G.; Shamim, Atif; Farooqui, Muhammad Fahad

    2015-01-01

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do

  6. A corrosion monitoring system for existing reinforced concrete structures.

    Science.gov (United States)

    2015-05-01

    This study evaluated a multi-parameter corrosion monitoring system for existing reinforced concrete structures in chloride-laden service environments. The system was fabricated based on a prototype concrete corrosion measurement system that : had bee...

  7. Reactivity Monitoring of Accelerator-Driven Nuclear Reactor Systems

    NARCIS (Netherlands)

    Uyttenhove, W.

    2016-01-01

    This thesis provides a methodology and set-up of a reactivity monitoring tool for Accelerator-Driven Systems (ADS). The reactivity monitoring tool should guarantee the operation of an ADS at a safe margin from criticality. Robustness is assured in different aspects of the monitoring tool: the choice

  8. Analysis of food radiation monitoring system in Belarus

    International Nuclear Information System (INIS)

    1992-01-01

    Food radiation monitoring system in Belarus due to the Chernobyl accident is analysed. Structure of radiation monitoring network, instrumentation and modern developments. Information on permissible concentration levels in foodstuffs and water is presented and calculations of radionuclide intake for man are performed. Proposals on the creation of social centres of food radiation monitoring for Belarussian population are considered. 4 tabs

  9. Garment design for an ambulatory pregnancy monitoring system

    NARCIS (Netherlands)

    Perusquia Hernandez, Monica; Chen, W.; Feijs, L.M.G.; Pecchia, L.; Chen, L.L.; Nugent, C.; Bravo, J.

    2014-01-01

    Constant pregnancy monitoring is a promising alternative to reduce the number of stillbirths and preterm delivery due to false alarms. Tele-monitoring systems can provide regular, accurate and timely monitoring to re-duce risks, costs and the time the mothers-to-be spend at hospitals. A smart

  10. Hydrological Monitoring System Design and Implementation Based on IOT

    Science.gov (United States)

    Han, Kun; Zhang, Dacheng; Bo, Jingyi; Zhang, Zhiguang

    In this article, an embedded system development platform based on GSM communication is proposed. Through its application in hydrology monitoring management, the author makes discussion about communication reliability and lightning protection, suggests detail solutions, and also analyzes design and realization of upper computer software. Finally, communication program is given. Hydrology monitoring system from wireless communication network is a typical practical application of embedded system, which has realized intelligence, modernization, high-efficiency and networking of hydrology monitoring management.

  11. Tuning permissiveness of active safety monitors for autonomous systems

    OpenAIRE

    Masson , Lola; Guiochet , Jérémie; Waeselynck , Hélène; Cabrera , Kalou; Cassel , Sofia; Törngren , Martin

    2018-01-01

    International audience; Robots and autonomous systems have become a part of our everyday life, therefore guaranteeing their safety is crucial.Among the possible ways to do so, monitoring is widely used, but few methods exist to systematically generate safety rules to implement such monitors. Particularly, building safety monitors that do not constrain excessively the system's ability to perform its tasks is necessary as those systems operate with few human interventions.We propose in this pap...

  12. Automatic acoustic and vibration monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Tothmatyas, Istvan; Illenyi, Andras; Kiss, Jozsef; Komaromi, Tibor; Nagy, Istvan; Olchvary, Geza

    1990-01-01

    A diagnostic system for nuclear power plant monitoring is described. Acoustic and vibration diagnostics can be applied to monitor various reactor components and auxiliary equipment including primary circuit machinery, leak detection, integrity of reactor vessel, loose parts monitoring. A noise diagnostic system has been developed for the Paks Nuclear Power Plant, to supervise the vibration state of primary circuit machinery. An automatic data acquisition and processing system is described for digitalizing and analysing diagnostic signals. (R.P.) 3 figs

  13. Optical monitoring system for a turbine engine

    Science.gov (United States)

    Lemieux, Dennis H; Smed, Jan P; Williams, James P; Jonnalagadda, Vinay

    2013-05-14

    The monitoring system for a gas turbine engine including a viewing tube assembly having an inner end and an outer end. The inner end is located adjacent to a hot gas flow path within the gas turbine engine and the outer end is located adjacent to an outer casing of the gas turbine engine. An aperture wall is located at the inner end of the viewing tube assembly and an optical element is located within the viewing tube assembly adjacent to the inner end and is spaced from the aperture wall to define a cooling and purge chamber therebetween. An aperture is defined in the aperture wall for passage of light from the hot gas flow path to the optical element. Swirl passages are defined in the viewing tube assembly between the aperture wall and the optical element for passage of cooling air from a location outside the viewing tube assembly into the chamber, wherein swirl passages effect a swirling movement of air in a circumferential direction within the chamber.

  14. Core monitoring system for FBR type reactor

    International Nuclear Information System (INIS)

    Azekura, Kazuo.

    1981-01-01

    Purpose: To determine power distribution ON-line after the change of the insertion degree of control rods by the provision of means for calculating power change coefficient at each of the points due to the change in the insertion degree from the specific change of insertion degree and multiplying the same with the newest power distribution determined periodically by the diffusion calculation. Constitution: The monitoring system additionally comprises a calculation device for power change coefficient that calculates the power change coefficient in a fuel assembly adjacent to a control rod based on the data concerning the operation of the control rod, and a provisional power distribution calculation device that executes multiplication between the power distribution calculated in a periodical power distribution calculation device based on the calculation instruction and stored in the core and the power change coefficient from the power change coefficient calculation device and forecasts the provisional power distribution. Then, based on the result of the foregoing calculations, 2-dimensional power distribution, maximum temperature for the cladding tube of the specified fuel assembly, maximum temperature of pellets in the specified fuel assembly, maximum power density and the like are calculated in various display value calculation devices and displayed on a display device. (Horiuchi, T.)

  15. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  16. FIREMON: Fire effects monitoring and inventory system

    Science.gov (United States)

    Duncan C. Lutes; Robert E. Keane; John F. Caratti; Carl H. Key; Nathan C. Benson; Steve Sutherland; Larry J. Gangi

    2006-01-01

    Monitoring and inventory to assess the effects of wildland fire is critical for 1) documenting fire effects, 2) assessing ecosystem damage and benefit, 3) evaluating the success or failure of a burn, and 4) appraising the potential for future treatments. However, monitoring fire effects is often difficult because data collection requires abundant funds, resources, and...

  17. Information system of partial monitoring system 'Radioactivity of the environment'

    International Nuclear Information System (INIS)

    Melicherova, T.

    2007-01-01

    Slovak Hydrometeorological Institute (SHMI) is operator of radiation monitoring from 1963. At present SHMI operates in its monitoring network 23 detectors GammaTracer fy Genitron, one mobile detector and one standby detector. Radiation data (dose rate in the unit nSv/h) from detectors in the automated meteorological stations are transmitted by data-logger and private institute network to National Telecommunication Centre in Bratislava. The data from MSS (message switch system) are inserted into the database. The 1 hours and 24 hours averages are computed on the server automatically. Delay between time of measurements and time of inserting data to database is only 10 min. Radiation files from SHMI network are on-line transmitted to information system of Nuclear Regulatory Authority of the Slovak Republic and to information system of Slovak Army. Transmission to to Crisis Centre of Civil Protection is under reconstruction at present. Database contains one table for radiation data and several tables for configurations, catalogues of stations and additional tables. Database works in environment client-server. On client PC runs the user front-end application. This application provides to display the data using many filters, to display tables with configurations concerning technical equipment, to display maps, graphs, etc. There is the possibility to store data into the archives, to make reports and to analyse data in the environment of professional statistical software. Precipitations values from meteorological stations were integrated do the information system of radiation monitoring for better interpretation of gamma dose rate values. SHMI cooperates in the radiation data exchange with European Commission Joint Research Centre in Ispra, Radiation Warning Centre in Vienna and Meteoservice Budapest. (author)

  18. Design Scheme of Remote Monitoring System Based on Qt

    Directory of Open Access Journals (Sweden)

    Xu Dawei

    2015-01-01

    Full Text Available This paper introduces a design scheme of remote monitoring system based on Qt, the scheme of remote monitoring system based on S3C2410 and Qt, with the aid of cross platform development tools Qt and powerful ARM platform design and implementation. The development of remote video surveillance system based on embedded terminal has practical significance and value.

  19. Passive sensor systems for nuclear material monitoring

    International Nuclear Information System (INIS)

    Simpson, M.L.; Boatner, L.A.; Holcomb, D.E.; McElhaney, S.A.; Mihalczo, J.T.; Muhs, J.D.; Roberts, M.R.; Hill, N.W.

    1993-01-01

    Passive fiber optic sensor systems capable of confirming the presence of special nuclear materials in storage or process facilities are being developed at Oak Ridge National Laboratory (ORNL). These sensors provide completely passive, remote measurement capability. No power supplies, amplifiers, or other active components that could degrade system reliability are required at the sensor location. ORNL, through its research programs in scintillator materials, has developed a variety of materials for use in alpha-, beta-, gamma-, and neutron-sensitive scintillator detectors. In addition to sensors for measuring radiation flux, new sensor materials have been developed which are capable of measuring weight, temperature, and source location. An example of a passive sensor for temperature measurement is the combination of a thermophosphor (e.g., rare-earth activated Y 2 O 3 ) with 6 LiF (95% 6 Li). This combination results in a new class of scintillators for thermal neutrons that absorb energy from the radiation particles and remit the energy as a light pulse, the decay rate of which, over a specified temperature range, is temperature dependent. Other passive sensors being developed include pressure-sensitive triboluminescent materials, weight-sensitive silicone rubber fibers, scintillating fibers, and other materials for gamma and neutron detection. The light from the scintillator materials of each sensor would be sent through optical fibers to a monitoring station, where the attribute quantity could be measured and compared with previously recorded emission levels. Confirmatory measurement applications of these technologies are being evaluated to reduce the effort, costs, and employee exposures associated with inventorying stockpiles of highly enriched uranium at the Oak Ridge Y-12 Plant

  20. Radiation monitoring of nuclear census intelligent data management and mobile monitoring data acquisition system

    International Nuclear Information System (INIS)

    Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo

    2014-01-01

    The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)

  1. Operational readiness of filtered air discharge monitoring systems

    International Nuclear Information System (INIS)

    Lafortune, J.F.; Jamieson, T.J.

    1993-08-01

    An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report

  2. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  3. Smart health monitoring systems: an overview of design and modeling.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  4. Satellite Based Cropland Carbon Monitoring System

    Science.gov (United States)

    Bandaru, V.; Jones, C. D.; Sedano, F.; Sahajpal, R.; Jin, H.; Skakun, S.; Pnvr, K.; Kommareddy, A.; Reddy, A.; Hurtt, G. C.; Izaurralde, R. C.

    2017-12-01

    Agricultural croplands act as both sources and sinks of atmospheric carbon dioxide (CO2); absorbing CO2 through photosynthesis, releasing CO2 through autotrophic and heterotrophic respiration, and sequestering CO2 in vegetation and soils. Part of the carbon captured in vegetation can be transported and utilized elsewhere through the activities of food, fiber, and energy production. As well, a portion of carbon in soils can be exported somewhere else by wind, water, and tillage erosion. Thus, it is important to quantify how land use and land management practices affect the net carbon balance of croplands. To monitor the impacts of various agricultural activities on carbon balance and to develop management strategies to make croplands to behave as net carbon sinks, it is of paramount importance to develop consistent and high resolution cropland carbon flux estimates. Croplands are typically characterized by fine scale heterogeneity; therefore, for accurate carbon flux estimates, it is necessary to account for the contribution of each crop type and their spatial distribution. As part of NASA CMS funded project, a satellite based Cropland Carbon Monitoring System (CCMS) was developed to estimate spatially resolved crop specific carbon fluxes over large regions. This modeling framework uses remote sensing version of Environmental Policy Integrated Climate Model and satellite derived crop parameters (e.g. leaf area index (LAI)) to determine vertical and lateral carbon fluxes. The crop type LAI product was developed based on the inversion of PRO-SAIL radiative transfer model and downscaled MODIS reflectance. The crop emergence and harvesting dates were estimated based on MODIS NDVI and crop growing degree days. To evaluate the performance of CCMS framework, it was implemented over croplands of Nebraska, and estimated carbon fluxes for major crops (i.e. corn, soybean, winter wheat, grain sorghum, alfalfa) grown in 2015. Key findings of the CCMS framework will be presented

  5. Design Of Pump Monitoring Of Primary Cooling System

    International Nuclear Information System (INIS)

    Indrakoesoema, Koes; Sujarwono

    2000-01-01

    Monitoring of 3 primary cooling pumps done visually by operator on the spot. The operator must be check oil in a sight glass, oil leakage during pump operation and water leakage. If reaktor power increase about more than 3 MW, the radiation exposure also increase in the primary cell and that's way the operator can not check the pumps. To continuing monitor all pump without delay, one system has been added I.e Closed Circuit Television (CCTV). This system using 3 video camera to monitor 3 pumps and connected to one receiver video monitor by coaxial cable located in Main Control Room. The sequence monitoring can be done by sequential switcher

  6. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  7. The cyclical monitoring system for digital power supplies at SSRF

    International Nuclear Information System (INIS)

    Tang Junlong; Li Deming; Shen Tianjian

    2009-01-01

    Based on available digital PS testing system and long-distance monitoring hardwares, the cyclical monitoring system for digital power supplies (PS) was developed at SSRF. Two models, i.e.long-distance cyclical monitoring and local cyclical monitoring, were established. The software developed in LabVIEW language was applied to the two models without any user interface modification. The user interface is simple. The system is suitable for debugging the digital PSs during long-distance monitoring and examining the performance. The long-distance model imitates the digital PSs' status for fault analysis and communication between the digital PS and the centre control room. The local model simultaneously examines stability of 18 new PSs for 24 h, monitors the PS controller, and detects malfunction. Parameters and status of the controller can be stored in Excel or Text file. The two models have been used at SSRF for monitoring the digital PSs. (authors)

  8. Design of Kartini reactor radiation monitor system using lab view

    International Nuclear Information System (INIS)

    Adi Abimanyu; Jumari; Achmad Fahrul Aji; Muhammad Khoiri

    2014-01-01

    Kartini Reactor operation will result in radiation exposure. Gamma radiation exposure rate at the Kartini Reactor monitored by several radiation monitors (Ludlum) that integrate with the computer, so that the rate of radiation exposure is always monitored. Current monitoring system combines six radiation monitor in one computer monitor radiation, and monitoring performed by operators and supervisors to see how the radiation exposure rate measured in the area around the reactor core in a periodic time manually. This research will develop a system to monitor radiation exposure in Kartini reactor based ATMega8 micro controller for interface between radiation monitor and computer and also Graphical User Interface (GUI) develop using Lab view software that makes monitoring is easier and documented regularly. This system is testing by simulation, it is done by replacing the function of the radiation monitoring devices (Ludlum) in Kartini Reactor with computers that send serial data with the same format with a format that is sent by Ludlum. The results show that the interface system has the ability to operate in a range of baud rate 1,200 bps, 2,400 bps, 4,800 bps, 9,600 bps, 14,400 bps, 19,200 bps and 38,400 bps, with the ability to provide realtime information every 6 seconds and able to document the rate of exposure to radiation in the form of logbook. (author)

  9. Expert systems for real-time monitoring and fault diagnosis

    Science.gov (United States)

    Edwards, S. J.; Caglayan, A. K.

    1989-01-01

    Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.

  10. Monitoring circuit for reactor safety systems

    Science.gov (United States)

    Keefe, Donald J.

    1976-01-01

    The ratio between the output signals of a pair of reactor safety channels is monitored. When ratio falls outside of a predetermined range, it indicates that one or more of the safety channels has malfunctioned.

  11. Monitoring circuit for reactor safety systems

    International Nuclear Information System (INIS)

    Keefe, D.J.

    1976-01-01

    The ratio between the output signals of a pair of reactor safety channels is monitored. When ratio falls outside of a predetermined range, it indicates that one or more of the safety channels has malfunctioned. 3 claims, 2 figures

  12. Wireless physiological monitoring system for psychiatric patients.

    Science.gov (United States)

    Rademeyer, A J; Blanckenberg, M M; Scheffer, C

    2009-01-01

    Patients in psychiatric hospitals that are sedated or secluded are at risk of death or injury if they are not continuously monitored. Some psychiatric patients are restless and aggressive, and hence the monitoring device should be robust and must transmit the data wirelessly. Two devices, a glove that measures oxygen saturation and a dorsally-mounted device that measures heart rate, skin temperature and respiratory rate were designed and tested. Both devices connect to one central monitoring station using two separate Bluetooth connections, ensuring a completely wireless setup. A Matlab graphical user interface (GUI) was developed for signal processing and monitoring of the vital signs of the psychiatric patient. Detection algorithms were implemented to detect ECG arrhythmias such as premature ventricular contraction and atrial fibrillation. The prototypes were manufactured and tested in a laboratory setting on healthy volunteers.

  13. Instrumentation for environmental monitoring in biological systems

    International Nuclear Information System (INIS)

    Amer, N.M.; Graven, R.M.; Budnitz, R.J.; Mack, D.A.

    1975-01-01

    A brief review of the status of instrumentation for monitoring environmental pollutants is given. Pollutants are divided into six broad categories: trace elements, pesticides and herbicides, ionizing radiation and radionuclides, asbestos and other microparticulates, and gaseous pollutants. (U.S.)

  14. As necessidades comunicacionais das práticas educativas na prevenção da transmissão materno-fetal do HIV Communication needs of education practices in preventing maternal-fetal HIV transmission

    Directory of Open Access Journals (Sweden)

    Katia Virginia de O Feliciano

    2003-12-01

    Full Text Available OBJETIVOS: elucidar a fecundidade da prática educativa centrada na prevenção da transmissão materno-fetal da AIDS para promover a comunicação usuárias-serviços. MÉTODOS: Estudo exploratório, parte de uma pesquisa sobre atenção pré-natal, realizado em 19 centros de saúde, duas maternidades e seis unidades de saúde da família da Secretaria de Saúde da cidade do Recife, de maio a julho de 1998. O processo de trabalho foi observado, equipes técnicas entrevistadas e um questionário foi aplicado às 355 mulheres em atendimento; dessas, 81 foram submetidas à sondagem. RESULTADOS: nenhum serviço faz aconselhamento, mesmo quando informam sobre o teste anti-HIV (48,1%. O trabalho educativo está focalizado no fornecimento de informações durante a consulta, pois, as atividades coletivas, nas unidades que realizam-nas (48,1%, não ocorrem em todos os horários do pré-natal. A prática educativa baseada na racionalidade estratégica subestima a importância da aproximação às decisões valorativas das mulheres, das quais somente 11,1% utilizam camisinha de modo sistemático. CONCLUSÕES: a pequena oferta de atividades educativas no pré-natal e o "monólogo tecnocrático" que predomina nas relações entre usuárias e serviços de saúde têm repercussões negativas na vulnerabilidade da população feminina e de seus filhos.OBJECTIVES: to determine the efficiency of educational methods in preventing maternal-fetal AIDS transmission through communication among users and health services providers. METHODS: exploratory study, part of the survey on pre-natal care, accomplished in 19 clinics, two maternity hospitals and six family health units performed by the Health Secretariat of the city of Recife, from May to July, 1998. Procedures were observed, technical teams were interviewed and questionnaires applied to 355 women being seen, of these, 81 participated of the survey. RESULTS: healthcare providers do not perform counseling, even

  15. Systems engineering approach towards performance monitoring of emergency diesel generator

    International Nuclear Information System (INIS)

    Nurhayati Ramli; Lee, Y.K.

    2013-01-01

    Full-text: Systems engineering is an interdisciplinary approach and means to enable the realization of successful systems. In this study, systems engineering approach towards the performance monitoring of Emergency Diesel Generator (EDG) is presented. Performance monitoring is part and parcel of predictive maintenance where the systems and components conditions can be detected before they result into failures. In an effort to identify the proposal for addressing performance monitoring, the EDG boundary has been defined. Based on the Probabilistic Safety Analysis (PSA) results and industry operating experiences, the most critical component is identified. This paper proposed a systems engineering concept development framework towards EDG performance monitoring. The expected output of this study is that the EDG reliability can be improved by the performance monitoring alternatives through the systems engineering concept development effort. (author)

  16. Rip current monitoring using GPS buoy system

    Science.gov (United States)

    Song, DongSeob; Kim, InHo; Kang, DongSoo

    2014-05-01

    The occurrence of rip current in the Haeundae beach, which is one of the most famous beaches in South Korea, has been threatening beach-goers security in summer season annually. Many coastal scientists have been investigating rip currents by using field observations and measurements, laboratory measurements and wave tank experiments, and computer and numerical modeling. Rip current velocity is intermittent and may rapidly increase within minutes due to larger incoming wave groups or nearshore circulation instabilities. It is important to understand that changes in rip current velocity occur in response to changes in incoming wave height and period as well as changes in water level. GPS buoys have been used to acquire sea level change data, atmospheric parameters and other oceanic variables in sea for the purposes of vertical datum determination, tide correction, radar altimeter calibration, ocean environment and marine pollution monitoring. Therefore, we adopted GPS buoy system for an experiment which is to investigate rip current velocity; it is sporadic and may quickly upsurge within minutes due to larger arriving wave groups or nearshore flow uncertainties. In this study, for high accurate positioning of buy equipment, a Satellite Based Argumentation System DGPS data logger was deployed to investigate within floating object, and it can be acquired three-dimensional coordinate or geodetic position of buoy with continuous NMEA-0183 protocol during 24 hours. The wave height measured by in-situ hydrometer in a cross-shore array clearly increased before and after occurrence of rip current, and wave period also was lengthened around an event. These results show that wave height and period correlate reasonably well with long-shore current interaction in the Haeundae beach. Additionally, current meter data and GPS buoy data showed that rip current velocities, about 0.2 m/s, may become dangerously strong under specific conditions. Acknowledgement This research was

  17. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System

    OpenAIRE

    Sungjun Kwon; Dongseok Lee; Jeehoon Kim; Youngki Lee; Seungwoo Kang; Sangwon Seo; Kwangsuk Park

    2016-01-01

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user?s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user?s high-level contexts, such as stress and affective state levels. In th...

  18. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-01-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs

  19. Automated wireless monitoring system for cable tension using smart sensors

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jongwoong; Cho, Soojin; Spencer, Billie F.; Yun, Chung-Bang

    2013-04-01

    Cables are critical load carrying members of cable-stayed bridges; monitoring tension forces of the cables provides valuable information for SHM of the cable-stayed bridges. Monitoring systems for the cable tension can be efficiently realized using wireless smart sensors in conjunction with vibration-based cable tension estimation approaches. This study develops an automated cable tension monitoring system using MEMSIC's Imote2 smart sensors. An embedded data processing strategy is implemented on the Imote2-based wireless sensor network to calculate cable tensions using a vibration-based method, significantly reducing the wireless data transmission and associated power consumption. The autonomous operation of the monitoring system is achieved by AutoMonitor, a high-level coordinator application provided by the Illinois SHM Project Services Toolsuite. The monitoring system also features power harvesting enabled by solar panels attached to each sensor node and AutoMonitor for charging control. The proposed wireless system has been deployed on the Jindo Bridge, a cable-stayed bridge located in South Korea. Tension forces are autonomously monitored for 12 cables in the east, land side of the bridge, proving the validity and potential of the presented tension monitoring system for real-world applications.

  20. Seismic monitoring: a unified system for research and verifications

    International Nuclear Information System (INIS)

    Thigpen, L.

    1979-01-01

    A system for characterizing either a seismic source or geologic media from observational data was developed. This resulted from an examination of the forward and inverse problems of seismology. The system integrates many seismic monitoring research efforts into a single computational capability. Its main advantage is that it unifies computational and research efforts in seismic monitoring. 173 references, 9 figures, 3 tables

  1. Personnel monitoring system by thermoluminescence dosimeter - a study and review

    International Nuclear Information System (INIS)

    Iyer, V.S.; Alok, M.; Chandel, B.S.

    2018-01-01

    The principle objective of personnel monitoring system is to prevent overexposure and avoid unnecessary exposure of personnel working with various sources of radiation. The adequate system of personnel monitoring must provide for the measurement. evaluation and recording of significant doses accumulated by individuals together with a recording of conditions under which these doses are received

  2. Partial monitoring system Radioactivity of the Environment, 2006

    International Nuclear Information System (INIS)

    Melicherova, T.

    2007-01-01

    In this report the Partial monitoring system 'Radioactivity of the Environment' for the year 2006 is presented. International co-operation of the Slovak Hydrometeorological Institute in the Partial monitoring system 'Radioactivity of the Environment' of the Slovak Republic, international co-operation as well as financial data are reviewed

  3. [A wireless mobile monitoring system based on bluetooth technology].

    Science.gov (United States)

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  4. Real time kernel performance monitoring with SystemTap

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    SystemTap is a dynamic method of monitoring and tracing the operation of a running Linux kernel. In this talk I will present a few practical use cases where SystemTap allowed me to turn otherwise complex userland monitoring tasks in simple kernel probes.

  5. Banking system and financial monitoring in Russian Federation

    Directory of Open Access Journals (Sweden)

    Osipov A.V.

    2017-04-01

    Full Text Available the article explores the definition of banking system and financial monitoring. Attention is emphasizes on role of internal control in aspect their relation to contraction to money laundering and financing of terrorism/ Internal control is analises from the point of view law, economic and management. Basic attention in the article author emphasizes on work of systems of financial monitoring in organizations.

  6. Experience with digital acoustic monitoring systems for PWRs and BWRs

    International Nuclear Information System (INIS)

    Olma, B.J.

    1998-01-01

    Substantial progress could be reached both in system technics and in application of digital acoustic monitoring systems for assessing mechanical integrity of reactor primary systems. For the surveillance of PWRs and BWRs during power operation of the plants, acoustic signals of Loose Parts Monitoring System sensors are continuously monitored for signal bursts associated with metallic impacts. ISTec/GRS experience with its digital systems MEDEA and RAMSES has shown that acoustic signature analysis is very successful for detecting component failures at an early stage. Methods for trending and classification of digital burst signals are shown, experience with their practical use will be presented. (author)

  7. The software design of area γ radiation monitoring system

    International Nuclear Information System (INIS)

    Song Chenxin; Deng Changming; Cheng Chang; Ren Yi; Meng Dan; Liu Yun

    2007-01-01

    This paper main introduction the system structure, software architecture, design ideas of the area γ radiation monitoring system. Detailed introduction some programming technology about the computer communication with the local display unit. (authors)

  8. The software design of area γ radiation monitoring system

    International Nuclear Information System (INIS)

    Song Chenxin; Deng Changming; Cheng Chang; Ren Yi; Meng Dan; Liu Yun

    2008-01-01

    This paper main introduction the system structure, software architecture, design ideas of the area γ radiation monitoring system. Detailed introduction some programming technology about the computer communication with the local display unit. (authors)

  9. Distributed Rocket Engine Testing Health Monitoring System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The on-ground and Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) provides a system architecture and software tools for performing diagnostics...

  10. Distributed Rocket Engine Testing Health Monitoring System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  11. Systems and methods for monitoring a solid-liquid interface

    Science.gov (United States)

    Stoddard, Nathan G; Lewis, Monte A.; Clark, Roger F

    2013-06-11

    Systems and methods are provided for monitoring a solid-liquid interface during a casting process. The systems and methods enable determination of the location of a solid-liquid interface during the casting process.

  12. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  13. System of message for gamma-radiation monitor

    International Nuclear Information System (INIS)

    Bolic, M.D.; Koturovic, A.M.

    2001-01-01

    Paper describes a system of voice messages for gamma-radiation monitor based on PC. The systems reproduces recorded messages that is simpler than the process of their synthesis. Message choice is based on combination of recorded digital results and/or received reference messages or warnings. The system of generation of voice messages applies the Windows based software. The total memory array required to create independent voice system is maximum 1.7 mbyte. The monitor may be used for continuous monitoring of radioactivity level with 5-8 s period of message repetition. Another option of the system operation is based on monitor application for the environment monitoring. Period of messages in this case is equal to 5-30 min [ru

  14. Standard-B Hydrogen Monitoring System, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1995-01-01

    During most of the year, it is assumed that the vapor in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gases to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gases from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. This document describes the design of the Standard-B Hydrogen Monitoring System, (SHMS) and its components as it differs from the original SHMS. The differences are derived from changes made to improve the system performance but not implemented in all the installed enclosures

  15. TLA monitoring of an anodic protection system

    International Nuclear Information System (INIS)

    Wallace, G.; Boulton, H.

    1992-01-01

    Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by corrosion. 14 refs., 7 figs., 4 tabs

  16. The ALICE data quality monitoring system

    International Nuclear Information System (INIS)

    Haller, B von; Telesca, A; Chapeland, S; Carena, F; Carena, W; Barroso, V Chibante; Costa, F; Denes, E; Divià, R; Fuchs, U; Simonetti, G; Soós, C; Vyvre, P Vande

    2011-01-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.

  17. The ALICE data quality monitoring system

    Science.gov (United States)

    von Haller, B.; Telesca, A.; Chapeland, S.; Carena, F.; Carena, W.; Chibante Barroso, V.; Costa, F.; Denes, E.; Divià, R.; Fuchs, U.; Simonetti, G.; Soós, C.; Vande Vyvre, P.; ALICE Collaboration

    2011-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.

  18. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  19. Study concerning an integrated radiation monitoring systems for nuclear facilities

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, M.; Cerga, V.; Pirvu, V; Badea, E.

    1996-01-01

    This paper presents an integrated radiation monitoring system designed to assess the effects of nuclear accidents and to provide a basis for making right decisions and countermeasures in order to reduce health damages. The system implies a number of stationary monitoring equipment, data processing unit and a communication network. The system meets the demands of efficiency and reliability, providing the needed tools to easily create programs able to process simple input data filling the information management system. (author). 10 refs

  20. [Implementation of ECG Monitoring System Based on Internet of Things].

    Science.gov (United States)

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  1. Development of mobile air pollution monitoring system (LIDAR)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyung Ki; Song, Kyu Seok; Kim, Dukh Yeon; Yang, Ki Ho; Lee, Jong Min; Yoon, S.; Rostov, A

    2001-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment and provide pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR(Light Detection And Ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The coal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols.

  2. Development of mobile air pollution monitoring system (LIDAR)

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Song, Kyu Seok; Kim, Dukh Yeon; Yang, Ki Ho; Lee, Jong Min; Yoon, S.; Rostov, A.

    2001-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment and provide pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR(Light Detection And Ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The coal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols

  3. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  4. Intelligent Monitoring of Rocket Test Systems

    Science.gov (United States)

    Duran, Esteban; Rocha, Stephanie; Figueroa, Fernando

    2016-01-01

    Stephanie Rocha is an undergraduate student pursuing a degree in Mechanical Engineering. Esteban Duran is pursuing a degree in Computer Science. Our mentor is Fernando Figueroa. Our project involved developing Intelligent Health Monitoring at the High Pressure Gas Facility (HPGF) utilizing the software GensymG2.

  5. A review on transient monitoring systems

    International Nuclear Information System (INIS)

    Baylac, G.

    1986-01-01

    A good design must be followed by the continuous verification during service of design basis hypotheses. Transient monitoring techniques described hereafter were developed to fulfill this very logical requirement. They are shown to be useful to improve the reliability, operability, inspection and lifetime of components of the Reactor Coolant Pressure Boundary. 16 refs.

  6. Decision Support System for Condition Monitoring Technologies

    NARCIS (Netherlands)

    Mouatamir, Abderrahim

    2018-01-01

    The technological feasibility of a condition-based maintenance (CBM) policy is intrinsically related to the suitable selection of condition monitoring (CM) technologies such as vibration- and oil analysis or other non-destructive testing (NDT) techniques such as radiographic- and magnetic particle

  7. An autonomic security monitor for distributed operating systems

    OpenAIRE

    Arenas, A.; Aziz, Benjamin; Maj, S.; Matthews, B.

    2011-01-01

    This paper presents an autonomic system for the monitoring of security-relevant information in a Grid-based operating system. The system implements rule-based policies using Java Drools. Policies are capable of controlling the system environment based on changes in levels of CPU/memory usage, accesses to system resources, detection of abnormal behaviour such as DDos attacks.

  8. Principles in wireless building health monitoring systems.

    Science.gov (United States)

    Pentaris, F. P.; Makris, J. P.; Stonham, J.; Vallianatos, F.

    2012-04-01

    Monitoring the structural state of a building is essential for the safety of the people who work, live, visit or just use it as well as for the civil protection of urban areas. Many factors can affect the state of the health of a structure, namely man made, like mistakes in the construction, traffic, heavy loads on the structures, explosions, environmental impacts like wind loads, humidity, chemical reactions, temperature changes and saltiness, and natural hazards like earthquakes and landslides. Monitoring the health of a structure provides the ability to anticipate structural failures and secure the safe use of buildings especially those of public services. This work reviews the state of the art and the challenges of a wireless Structural Health Monitoring (WiSHM). Literature review reveals that although there is significant evolution in wireless structural health monitoring, in many cases, monitoring by itself is not enough to predict when a structure becomes inappropriate and/or unsafe for use, and the damage or low durability of a structure cannot be revealed (Chintalapudi, et al., 2006; Ramos, Aguilar, & Lourenço, 2011). Several features and specifications of WiSHM like wireless sensor networking, reliability and autonomy of sensors, algorithms of data transmission and analysis should still be evolved and improved in order to increase the predictive effectiveness of the SHM (Jinping Ou & Hui Li, 2010; Lu & Loh, 2010) . Acknowledgments This work was supported in part by the ARCHEMEDES III Program of the Ministry of Education of Greece and the European Union in the framework of the project entitled «Interdisciplinary Multi-Scale Research of Earthquake Physics and Seismotectonics at the front of the Hellenic Arc (IMPACT-ARC) ».

  9. Upgrade of the monitoring system of LHCb ECAL

    CERN Document Server

    Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei

    2016-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.

  10. Continuous monitoring system for environmental {gamma} radiation near nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Jin; Qingyu, Yue; Wenhai, Wang [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1996-06-01

    The continuous monitoring system which is used for the environmental routine and accident emergency {gamma} radiation monitoring near nuclear facility is described. The continuous monitoring system consists of a high pressurized ionization chamber, integrated weak current amplifier, V/F converter and intelligent data recorder. The data gained by recorder can be transmitted to a PC through a standard RS-232-C interface for the data handling and graph plotting. This continuous monitoring system has the functions of alarm over threshold and recorded output signal of detector and temperature. The measuring range is from 10 nGy{center_dot}h{sup -1} to 10 mGy{center_dot}h{sup -1} because a high insulation switch atomically changed measuring ranges is used. The monitoring system has been operating continuously for a long time with high stability and reliability. (5 figs., 2 tabs.).

  11. Continuous monitoring system for environmental γ radiation near nuclear facility

    International Nuclear Information System (INIS)

    Jin Hua; Yue Qingyu; Wang Wenhai

    1996-06-01

    The continuous monitoring system which is used for the environmental routine and accident emergency γ radiation monitoring near nuclear facility is described. The continuous monitoring system consists of a high pressurized ionization chamber, integrated weak current amplifier, V/F converter and intelligent data recorder. The data gained by recorder can be transmitted to a PC through a standard RS-232-C interface for the data handling and graph plotting. This continuous monitoring system has the functions of alarm over threshold and recorded output signal of detector and temperature. The measuring range is from 10 nGy·h -1 to 10 mGy·h -1 because a high insulation switch atomically changed measuring ranges is used. The monitoring system has been operating continuously for a long time with high stability and reliability. (5 figs., 2 tabs.)

  12. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  13. Research and Implementation of Distributed Database HBase Monitoring System

    Directory of Open Access Journals (Sweden)

    Guo Lisi

    2017-01-01

    Full Text Available With the arrival of large data age, distributed database HBase becomes an important tool for storing data in massive data age. The normal operation of HBase database is an important guarantee to ensure the security of data storage. Therefore designing a reasonable HBase monitoring system is of great significance in practice. In this article, we introduce the solution, which contains the performance monitoring and fault alarm function module, to meet a certain operator’s demand of HBase monitoring database in their actual production projects. We designed a monitoring system which consists of a flexible and extensible monitoring agent, a monitoring server based on SSM architecture, and a concise monitoring display layer. Moreover, in order to deal with the problem that pages renders too slow in the actual operation process, we present a solution: reducing the SQL query. It has been proved that reducing SQL query can effectively improve system performance and user experience. The system work well in monitoring the status of HBase database, flexibly extending the monitoring index, and issuing a warning when a fault occurs, so that it is able to improve the working efficiency of the administrator, and ensure the smooth operation of the project.

  14. Modern diagnostic systems for loose parts, vibration and leakage monitoring

    International Nuclear Information System (INIS)

    Kunze, U.

    1997-01-01

    The modern diagnostic systems for loose parts, vibration and leakage monitoring of Siemens marked improvements in signal detection, ease of operation, and the display of information. The paper gives an overview on: Loose parts monitoring system KUeS '95 - a computer-based system. The knowledge and experience about loose parts detection incorporated into this system can be characterized as ''intelligence''. Vibration monitoring system SUeS '95 - a fully automated system for early detection of changes in the vibration patterns of the reactor coolant system components and reactor pressure vessel internals. Leak detection system FLUeS - a system that detects even small leaks in steam-carrying components and very accurately determines their location. Leaks are detected on the moisture distribution in a sample air column into which the escaping steam locally diffuses. All systems described represent the latest state of technology. Nevertheless a considerable amount of operational experience can be reported. (author). 5 refs, 10 figs

  15. The evolution of industrial power monitoring and control systems

    Energy Technology Data Exchange (ETDEWEB)

    Nicholson, K. E.

    1998-04-01

    The evolution of power monitoring and control systems in industrial situations are described. Computer-based PMC (power monitoring and control) systems are discussed in two sections. Section 1 covers the PC/DOS based systems in use up to the 1990s. These systems had multitasking capability, sufficient for scanning a serial line running a multi-drop protocol to field instruments, which in turn were running either proprietary or PLC subsets, maintaining a level of operator display, data logging and query support. Since the mid-1990s the second generation of industrial power monitoring and control systems based on the PC/NT system came into use, driven to market by three factors: (1) availability of low cost PCs, (2) widespread availability of computer networking technologies, and (3) the appearance of the robust, industrially viable NT operating system. Second generation systems are characterized by division into two tiers; a monitoring system focused on remote metering, and a second tier of a modular system capable of fully implementing both power monitoring and supervisory control. Looking toward the future, the requirements for systems is expected to become more unique, driven by the need for information for energy procurement decision making, automatic control for integrating power acquisition from multiple suppliers, power capacity and integrated power and production control planning needs, and power quality and reliability issues. A review of the functionality of PMC systems, and system architectures was also provided. Results of a survey of PMC systems applications were also discussed. 2 refs., 4 tabs., 8 figs.

  16. Experience with neutron flux monitoring systems qualified for post-accident monitoring

    International Nuclear Information System (INIS)

    Shugars, H.G.; Miller, J.F.

    1995-01-01

    In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs

  17. Structural health monitoring system/method using electroactive polymer fibers

    Science.gov (United States)

    Scott-Carnell, Lisa A. (Inventor); Siochi, Emilie J. (Inventor)

    2013-01-01

    A method for monitoring the structural health of a structure of interest by coupling one or more electroactive polymer fibers to the structure and monitoring the electroactive responses of the polymer fiber(s). Load changes that are experienced by the structure cause changes in the baseline responses of the polymer fiber(s). A system for monitoring the structural health of the structure is also provided.

  18. IEEE 802.11 ECG monitoring system.

    Science.gov (United States)

    Tejero-Calado, Juan; Lopez-Casado, Carmen; Bernal-Martin, Antonio; Lopez-Gomez, Miguel; Romero-Romero, Marco; Quesada, Guillermo; Lorca, Julio; Rivas, Ramon

    2005-01-01

    New wireless technologies make possible the implementation of high level integration wireless devices which allow the replacement of traditional large wired monitoring devices. This kind of devices favours at-home hospitalization, reducing the affluence to sanitary assistance centers to make routine controls. This fact causes a really favourable social impact, especially for elder people, rural-zone inhabitant, chronic patients and handicapped people. Furthermore, it offers new functionalities to physicians and will reduce the sanitary cost. Among these functionalities, biomedical signals can be sent to other devices (screen, PDA, PC...) or processing centers, without restricting the patients' mobility. The aim of this project is the development and implementation of a reduced size multi-channel electrocardiograph based on IEEE 802.11, which allows wireless monitoring of patients, and the insertion of the information into the TCP/IP Hospital network.

  19. Monitoring Distributed Systems: A Relational Approach.

    Science.gov (United States)

    1982-12-01

    4. Summary 200 • 0" List of Figures Iv List of Figures Figure 2-1: Relationships between Primitive and Derived Events and Periods 15 Figure 3-1...structure in order to ensure specified invariants. usually relating to synchronization [Hoare 74). Both definitions emphasize the control, rather than the...monitor must understand that there are such things as proces- sors. processes, memory, message ports, semaphores , etc. and that certain relationships

  20. Modification of GNPS environment radiation monitoring network system

    International Nuclear Information System (INIS)

    Jiang Lili; Cao Chunsheng

    1999-01-01

    GNPS Environment Radiation Continuous Monitoring System (KRS), the only real time on-line system of site radiation monitoring, was put into service in 1993 prior to the first loading the the plant. It is revealed through several years of operation that this system has some deficiencies such as inadequate real time monitoring means, no figure and diagram display function on the central computer, high failures, frequent failure warning signals, thus making the availability of the system at a low level. In recent years, with the rapid development of computer network technology and increasingly strict requirements on the NPP environment protection raised by the government and public, KRS modification had become necessary and urgent. In 1996, GNPS carried out modification work on the measuring geometry condition of γ radiation monitoring sub-station and lightening protection. To enhance the functions of real time monitoring and data auto-processing, further modification of the system was made in 1998, including the update of the software and hardware of KRS central processor, set-up of system computer local network and database. In this way, the system availability and monitoring quality are greatly improved and effective monitoring and analysis means are provided for gaseous release during normal operation and under accident condition