WorldWideScience

Sample records for mastocytosis display distinct

  1. Dermoscopic features of skin lesions in patients with mastocytosis.

    Science.gov (United States)

    Vano-Galvan, Sergio; Alvarez-Twose, Iván; De las Heras, Elena; Heras, Elena De Las; Morgado, J M; Matito, Almudena; Sánchez-Muñoz, Laura; Plana, Maria N; Planas, Maria Nieves; Jaén, Pedro; Orfao, Alberto; Escribano, Luis

    2011-08-01

    To evaluate dermoscopic features in a group of 127 patients with mastocytosis in the skin and to investigate the relationship between different dermoscopic patterns and other clinical and biological characteristics of the disease. Clinical and laboratory data were compared among patients with mastocytosis grouped according to the different dermoscopic patterns. Patients were selected from the Instituto de Estudios de Mastocitosis de Castilla La Mancha and the Department of Dermatology of Hospital Universitario Ramón y Cajal from April 1 through September 30, 2009. Patients Overall, 127 consecutive patients (70 females [55.1%] and 57 males [44.9%]; median age, 17 years; range, 0-81 years) with mastocytosis in the skin were included in the study. Evaluation of dermoscopic patterns and investigation of potential predictive factors for more symptomatic forms of the disease according to the need for daily antimediator therapy. Four distinct dermoscopic patterns were observed: yellow-orange blot, pigment network, reticular vascular pattern, and (most frequently) light-brown blot. A reticular vascular pattern was identified in all telangiectasia macular eruptiva and some maculopapular mastocytosis. In turn, all patients with mastocytoma displayed the yellow-orange blot pattern. The reticular vascular dermoscopic pattern was associated with the need for daily antimediator therapy; this pattern, together with serum tryptase levels and plaque-type mastocytosis, represented the best combination of independent factors to predict the need for maintained antimediator therapy. Dermoscopy is a feasible method for the subclassification of mastocytosis. Of note, a reticular vascular pattern is more frequently associated with the need for antimediator therapy.

  2. Mastocytosis: magnetic resonance imaging patterns of marrow disease

    International Nuclear Information System (INIS)

    Avila, N.A.; Ling, A.; Metcalfe, D.D.; Worobec, A.S.

    1998-01-01

    Objective. To report the bone marrow MRI findings of patients with mastocytosis and correlate them with clinical, pathologic, and radiographic features. Design and patients. Eighteen patients with mastocytosis had T1-weighted spin echo and short tau inversion recovery MRI of the pelvis at 0.5 T. In each patient the MR pattern of marrow disease was classified according to intensity and uniformity and was correlated with the clinical category of mastocytosis, bone marrow biopsy results, and radiographic findings. Results. Two patients had normal MRI scans and normal bone marrow biopsies. One patient had a normal MRI scan and a marrow biopsy consistent with mastocytosis. Fifteen patients had abnormal MRI scans and abnormal marrow biopsies. There were several different MR patterns of marrow involvement; none was specifically associated with any given clinical category of mastocytosis. Fifteen of the 18 patients had radiographs of the pelvis; of those, 13 with abnormal MRI scans and abnormal marrow biopsies had the following radiographic findings: normal (nine); sclerosis (three); diffuse osteopenia (one). Conclusion. While radiographs are very insensitive for the detection of marrow abnormalities in mastocytosis, MRI is very sensitive and may display several different patterns of marrow involvement. (orig.)

  3. Mastocytosis of the female breast.

    Science.gov (United States)

    Setia, Namrata; Crisi, Giovanna M; Pantanowitz, Liron

    2010-10-01

    A subset of patients with systemic mastocytosis may manifest with extracutaneous involvement. To the best of our knowledge, mastocytosis of the human breast has not been described. This study reports a case with mastocytosis involving the breasts of a 33-year-old woman associated with mammary hypertrophy (breast mastocytosis). The potential for infiltrating mast cells to mimic lobular carcinoma is emphasized and the relationship to breast hypertrophy in this case is discussed.

  4. Mastocytosis and insect venom allergy.

    Science.gov (United States)

    Bonadonna, Patrizia; Zanotti, Roberta; Müller, Ulrich

    2010-08-01

    To analyse the association of systemic allergic hymenoptera sting reactions with mastocytosis and elevated baseline serum tryptase and to discuss diagnosis and treatment in patients with both diseases. In recent large studies on patients with mastocytosis a much higher incidence of severe anaphylaxis following hymenoptera stings than in the normal population was documented. In patients with hymenoptera venom allergy, elevated baseline tryptase is strongly associated with severe anaphylaxis. Fatal sting reactions were reported in patients with mastocytosis, notably after stopping venom immunotherapy. During venom immunotherapy most patients with mastocytosis are protected from further sting reactions. Based on these observations immunotherapy for life is recommended for patients with mastocytosis and venom allergy. The incidence of allergic side-effects is increased in patients with mastocytosis and elevated baseline tryptase, especially in those allergic to Vespula venom. Premedication with antihistamines, or omalizumab in cases with recurrent severe side-effects, can be helpful. In all patients with anaphylaxis following hymenoptera stings, baseline serum tryptase should be determined. A value above 11.4 microg/l is often due to mastocytosis and indicates a high risk of very severe anaphylaxis following re-stings. Venom immunotherapy is safe and effective in this situation.

  5. Multidisciplinary Management of Mastocytosis

    DEFF Research Database (Denmark)

    Broesby-Olsen, Sigurd; Dybedal, Ingunn; Gülen, Theo

    2016-01-01

    Mastocytosis is a heterogeneous group of diseases defined by an increased number and accumulation of mast cells, and often also by signs and symptoms of mast cell activation. Disease subtypes range from indolent to rare aggressive forms. Mastocytosis affects people of all ages and has been...... an individualized, multidisciplinary approach. We present here consensus recommendations from a Nordic expert group for the diagnosis and general management of patients with mastocytosis....

  6. Multidisciplinary Management of Mastocytosis

    DEFF Research Database (Denmark)

    Broesby-Olsen, Sigurd; Dybedal, Ingunn; Gülen, Theo

    2016-01-01

    Mastocytosis is a heterogeneous group of diseases defined by an increased number and accumulation of mast cells, and often also by signs and symptoms of mast cell activation. Disease subtypes range from indolent to rare aggressive forms. Mastocytosis affects people of all ages and has been consid...... an individualized, multidisciplinary approach. We present here consensus recommendations from a Nordic expert group for the diagnosis and general management of patients with mastocytosis....

  7. Treatment strategies in mastocytosis

    DEFF Research Database (Denmark)

    Siebenhaar, Frank; Akin, Cem; Bindslev-Jensen, Carsten

    2014-01-01

    Treatment recommendations for mastocytosis are based mostly on expert opinion rather than evidence obtained from controlled clinical trials. In this article, treatment options for mastocytosis are presented, with a focus on the control of mediator-related symptoms in patients with indolent disease....

  8. Advances in the classification and treatment of mastocytosis

    DEFF Research Database (Denmark)

    Valent, Peter; Akin, Cem; Hartmann, Karin

    2017-01-01

    Mastocytosis is a term used to denote a heterogeneous group of conditions defined by the expansion and accumulation of clonal (neoplastic) tissue mast cells in various organs. The classification of the World Health Organization (WHO) divides the disease into cutaneous mastocytosis, systemic...... leukemia. The clinical impact and prognostic value of this classification has been confirmed in numerous studies, and its basic concept remains valid. However, refinements have recently been proposed by the consensus group, the WHO, and the European Competence Network on Mastocytosis. In addition, new...... of mastocytosis, with emphasis on classification, prognostication, and emerging new treatment options in advanced systemic mastocytosis....

  9. Epidemiology of systemic mastocytosis in Denmark

    DEFF Research Database (Denmark)

    Cohen, Sarah; Hoffmann, Stine Skovbo; Vestergaard, Hanne

    2014-01-01

    Mastocytosis is a heterogeneous group of diseases characterized by abnormal proliferation of mast cells. Systemic mastocytosis (SM), in which abnormal mast cells are present in tissues beyond the skin, is divided into seven subcategories with varying degrees of severity and prognosis. Very little......%), followed by SM with subtype unknown (n = 61; 11%), SM with associated clonal haematological non-mast cell lineage disease (n = 24; 4%), aggressive SM (n = 8; 2%), and mast cell leukaemia (n = 5; 1%). The incidence rate for SM (all subtypes including urticaria pigmentosa) was 0_89 per 100 000 per year...... to be overall relatively rare with notable variation by subtype for patient characteristics, survival and epidemiological measures. Keywords: aggressive systemic mastocytosis, indolent systemic mastocytosis, urticaria pigmentosa, epidemiology, Denmark....

  10. Systemic mastocytosis - A systematic review

    DEFF Research Database (Denmark)

    Andersen, C.L.; Hasselbalch, H.C.; Kristensen, T.K.

    2012-01-01

    of the cell has been described and its fascinating biology has only recently been depicted. We here give a review of systemic mastocytosis in regards to cell biology, diagnostic approaches and clinical practice. METHODS: A search was made in PubMed in August 2011 entering the keywords: mastocytosis, (systemic...

  11. Cutaneous manifestations in patients with mastocytosis

    DEFF Research Database (Denmark)

    Hartmann, Karin; Escribano, Luis; Grattan, Clive

    2016-01-01

    with mastocytosis. To address this unmet need, an international task force involving experts from different organizations (including the European Competence Network on Mastocytosis; the American Academy of Allergy, Asthma & Immunology; and the European Academy of Allergology and Clinical Immunology) met several...... times between 2010 and 2014 to discuss the classification and criteria for diagnosis of cutaneous manifestations in patients with mastocytosis. This article provides the major outcomes of these meetings and a proposal for a revised definition and criteria. In particular, we recommend that the typical...

  12. Interferon-α treatment in systemic mastocytosis

    DEFF Research Database (Denmark)

    Bjerrum, Ole Weis

    2011-01-01

    classification need treatment. This review on interferon treatment in systemic mastocytosis documents an effect of this biological agent in some patients with mastocytosis. However, the place of interferon-a, as mono- or combination therapy, in the treatment algorithm may only be definitely established...

  13. European Competence Network on Mastocytosis (ECNM)

    DEFF Research Database (Denmark)

    Valent, Peter; Arock, Michel; Bonadonna, Patrizia

    2012-01-01

    The European Competence Network on Mastocytosis (ECNM) was initiated in 2002 as a multidisciplinary and multinational cooperative approach to increase awareness and to improve diagnosis and therapy of mastocytosis. The network is composed of local centers, physicians, and scientists who have dedi...

  14. Case report 561: Systemic mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Schweitzer, M.E.; Irwin, G.A.L. (Nassau County Medical Center, East Meadow, NY (USA). Dept. of Radiology)

    1989-08-01

    A case is presented of a 55-year-old man with systemic mastocytosis. CT studies showed mesenteric and retroperetoneal lymphadenopathy, hepatosplenomegaly and sclerotic lesions of lumbar vertebrae. Lesions of the skin were absent. Pathological studies of lymph nodes indicated the presence of mastocytosis. The clinical, radiological and pathological features of this disorder and its five forms were discussed. Prognosis and treatment were also considered. (orig./GDG).

  15. Diffuse Cutaneous Mastocytosis in a Child - a Case Report

    Directory of Open Access Journals (Sweden)

    Popadić Svetlana

    2017-09-01

    Full Text Available Mastocytosis refers to a group of diseases characterized by a clonal proliferation and accumulation of mast cells in one or more tissues/organs with different clinical presentations. In children, limited cutaneous forms of mastocytosis are rather frequent, while systemic mastocytosis is rare. The diagnosis of cutaneous mastocytosis is based on clinical findings and histopathology. We present a patient who developed skin lesions at the age of 18 months. Clinical findings, confirmed by histopathology, were consistent with diffuse cutaneous mastocytosis. The follow-up period was 7 years. The treatment included oral antihistamines in combination with mast cell stabilizers, mild topical steroids and avoidance of friction. During the follow-up period, there were no signs of systemic involvement, and the quality of life was preserved, despite the large surface of affected skin. This case report should increase the awareness and knowledge of clinicians about this rare form of cutaneous mastocytosis in the pediatric population.

  16. Guidelines for the Diagnosis and Treatment of Cutaneous Mastocytosis in Children

    Science.gov (United States)

    Castells, Mariana; Metcalfe, Dean D.; Escribano, Luis

    2012-01-01

    Mastocytosis is a disease with many variants, all of which are characterized by a pathologic increase in mast cells in cutaneous tissue and extracutaneous organs such as the bone marrow, liver, spleen and lymph nodes. The disease presents in two primary age-related patterns: pediatric-onset mastocytosis and adult-onset mastocytosis, which may differ in their clinical manifestations and disease course. Pediatric-onset mastocytosis commonly is diagnosed prior to 2 years of age, and usually consists of cutaneous disease, with urticaria pigmentosa (UP) the most common pattern. The course of pediatric-onset mastocytosis is variable. This is in contrast to adult onset disease which generally presents with systemic findings and increases in extent and severity over time. Because pediatric forms of mastocytosis often differ in presentation and prognosis from adult variants, it is most important to understand pediatric mastocytosis and not rely on adult approaches as a guide on how to identify and manage disease. This is especially important in selecting therapy where antiproliferative agents have a very different set of concerns when used to treat adult mastocytosis compared to pediatric mastocytosis, especially in terms of long-term toxicity. This review is directed at providing age-specific information surrounding the care of the child with mastocytosis. PMID:21668033

  17. Findings of skin and bones in mastocytosis

    International Nuclear Information System (INIS)

    Rohner, H.G.; Bartl, R.; Koischwitz, D.; Rodermund, O.E.

    1982-01-01

    The syndrome of mastocytosis can include isolated urticaria pigmentosa, systemic mastocytosis, or the extremely rare form of mast cell leucemia. Our investigations of many patients have shown more frequently than earlier suspected, that the mastocytosis is a systemic disease. The frequency of attacked bone marrow is noteworthy. Because of the inflammatorygranulomatous manifestation in bone marrow, considerations of the pathogenesis of an immune and reactive event are taken into account. The mast cell granulomas are mostly found in the endosteal region, which is the reason for frequenctly occurring bone lesions (half on all patients show bone lesions). The bone changes can develop generalized (osteoporosis-osteosclerosis) or localized (osteolytic-osteosclerotic foci). In clinical work bone biopsies and skeletal radiology are supplementing each other: bone biopsy and skin biopsy give the first diagnosis of mastocytosis and reveal the systemic disease; X-ray pictures give information of shape and dimension of the induced osteopathy. (orig.)

  18. Findings of skin and bones in mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rohner, H.G.; Bartl, R.; Koischwitz, D.; Rodermund, O.E.

    1982-12-01

    The syndrome of mastocytosis can include isolated urticaria pigmentosa, systemic mastocytosis, or the extremely rare form of mast cell leucemia. Our investigations of many patients have shown more frequently than earlier suspected, that the mastocytosis is a systemic disease. The frequency of attacked bone marrow is noteworthy. Because of the inflammatory granulomatous manifestation in bone marrow, considerations of the pathogenesis of an immune and reactive event are taken into account. The mast cell granulomas are mostly found in the endosteal region, which is the reason for frequently occurring bone lesions (half of all patients show bone lesions). The bone changes can develop generalized (osteoporosis-osteosclerosis) or localized (osteolytic-osteosclerotic foci). In clinical work bone biopsies and skeletal radiology are supplementing each other: bone biopsy and skin biopsy give the first diagnosis of mastocytosis and reveal the systemic disease; X-ray pictures give information of shape and dimension of the induced osteopathy.

  19. Case report 369: Systemic mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodenberg, J.C.; Maegaard, K.K.; Svanholm, H.

    1986-05-01

    In summary, the case of a 58-year-old woman with upper gastrointestinal symptoms and a reddish-brown skin rash over a number of years has been presented. Biopsies from various sites, including bone marrow, were negative initially. A repeat cutaneous biopsy demonstrated the presence of systemic mastocytis. The characteristic clinical and radiological aspects of mastocytosis were described and the pathological features also were considered. A relevant differential diagnosis of the sclerotic form of mastocytosis was presented.

  20. Pregnancy and Delivery in Patients with Mastocytosis Treated at the Polish Center of the European Competence Network on Mastocytosis (ECNM.

    Directory of Open Access Journals (Sweden)

    Katarzyna Ciach

    Full Text Available To present current guidelines regarding treatment of mastocytosis in pregnancy on the example of observed patients.Case control national study.Polish Center of the European Competence Network on Mastocytosis (ECNM.23 singleton spontaneous pregnancies in 17 women diagnosed with mastocytosis in years 1999-2014, before becoming pregnant.Prospective analysis outcomes of pregnancies and deliveries.Survey developed in cooperation with the Spanish Instituto de Estudios de Mastocitosis de Castilla-La Mancha (CLMast, Hospital Virgen del Valle, Toledo, Red Espańola de Mastocitosis (REMA, Spain.All 23 pregnancies resulted from natural conception. Obstetrical complications recorded in the first trimester included spontaneous miscarriage (5 pregnancies. Four patients delivered preterm, including one delivery due to preeclampsia at 26 weeks which resulted with neonate death due to extreme prematurity. Five women delivered via cesarean: four due to obstetrical indications and one due to mastocytosis, during which no anesthesia related complications were recorded. Of patients delivering vaginally, two received extradural anesthesia, three required oxytocin infusion due to uterine hypotonia. No labor complications were recorded. In one woman with pregnancy-induced hypertension, early puerperium was complicated by the presence of persistent arterial hypertension. One neonate was born with the signs of cutaneous mastocytosis. Another neonate was diagnosed with Patau syndrome. Four women were treated for mastocytosis prior to conception and continued therapy after becoming pregnant. One patient was put on medications in the first trimester due to worsening of her symptoms. Pregnancy exerted only a slight effect on the intensity and frequency of mastocytosis-related symptoms observed. Worsening of the disease-related symptoms was documented in only four patients (23%. None of the patients showed the signs of anaphylaxis, either before becoming pregnant, or during

  1. Pregnancy and Delivery in Patients with Mastocytosis Treated at the Polish Center of the European Competence Network on Mastocytosis (ECNM).

    Science.gov (United States)

    Ciach, Katarzyna; Niedoszytko, Marek; Abacjew-Chmylko, Anna; Pabin, Izabela; Adamski, Przemyslaw; Leszczynska, Katarzyna; Preis, Krzysztof; Olszewska, Hanna; Wydra, Dariusz G; Hansdorfer-Korzon, Rita

    2016-01-01

    To present current guidelines regarding treatment of mastocytosis in pregnancy on the example of observed patients. Case control national study. Polish Center of the European Competence Network on Mastocytosis (ECNM). 23 singleton spontaneous pregnancies in 17 women diagnosed with mastocytosis in years 1999-2014, before becoming pregnant. Prospective analysis outcomes of pregnancies and deliveries. Survey developed in cooperation with the Spanish Instituto de Estudios de Mastocitosis de Castilla-La Mancha (CLMast), Hospital Virgen del Valle, Toledo, Red Espańola de Mastocitosis (REMA), Spain. All 23 pregnancies resulted from natural conception. Obstetrical complications recorded in the first trimester included spontaneous miscarriage (5 pregnancies). Four patients delivered preterm, including one delivery due to preeclampsia at 26 weeks which resulted with neonate death due to extreme prematurity. Five women delivered via cesarean: four due to obstetrical indications and one due to mastocytosis, during which no anesthesia related complications were recorded. Of patients delivering vaginally, two received extradural anesthesia, three required oxytocin infusion due to uterine hypotonia. No labor complications were recorded. In one woman with pregnancy-induced hypertension, early puerperium was complicated by the presence of persistent arterial hypertension. One neonate was born with the signs of cutaneous mastocytosis. Another neonate was diagnosed with Patau syndrome. Four women were treated for mastocytosis prior to conception and continued therapy after becoming pregnant. One patient was put on medications in the first trimester due to worsening of her symptoms. Pregnancy exerted only a slight effect on the intensity and frequency of mastocytosis-related symptoms observed. Worsening of the disease-related symptoms was documented in only four patients (23%). None of the patients showed the signs of anaphylaxis, either before becoming pregnant, or during pregnancy

  2. Rush immunotherapy for wasp venom allergy seems safe and effective in patients with mastocytosis.

    Science.gov (United States)

    Verburg, M; Oldhoff, J M; Klemans, R J B; Lahey-de Boer, A; de Bruin-Weller, M S; Röckmann, H; Sanders, C; Bruijnzeel-Koomen, C A F M; Pasmans, S G M A; Knulst, A C

    2015-11-01

    Patients with mastocytosis and wasp venom allergy (WA) may benefit from venom immunotherapy (VIT). However, fatal insect sting reactions have been described in mastocytosis patients despite previous immunotherapy. We investigated the safety and efficacy of (rush) VIT in patients with mastocytosis and WA. To investigate the safety and efficacy of (rush) VIT in patients with mastocytosis and WA. We describe nine patients with cutaneous mastocytosis and WA who received VIT. Cutaneous mastocytosis was confirmed by histopathology and systemic mastocytosis was diagnosed according to World Health Organization criteria. VIT was given according to a rush protocol. Given the difference in safety and efficacy of VIT in patients with WA and honeybee venom allergy, we reviewed the literature for VIT with the focus on WA patients with mastocytosis and addressed the difference between patients with cutaneous versus systemic mastocytosis. Nine patients had WA and mastocytosis, of whom six had cutaneous mastocytosis, two combined cutaneous and systemic mastocytosis and one systemic mastocytosis. All patients received rush IT with wasp venom. Most patients had only mild local side effects, with no systemic side effects during the course of VIT. One patient had a systemic reaction upon injection on one occasion, during the updosing phase, with dyspnoea and hypotension, but responded well to treatment. Immunotherapy was continued after temporary dose adjustment without problems. Two patients with a previous anaphylactic reaction were re-stung, without any systemic effects. VIT is safe in cutaneous mastocytosis patients with WA, while caution has to be made in case of systemic mastocytosis. VIT was effective in the patients who were re-stung.

  3. Update on Mastocytosis (Part 2): Categories, Prognosis, and Treatment.

    Science.gov (United States)

    Azaña, J M; Torrelo, A; Matito, A

    2016-01-01

    Mastocytosis is a term used to describe a heterogeneous group of disorders characterized by clonal proliferation of mast cells in different organs. The organ most often affected is the skin. The World Health Organization classifies cutaneous mastocytosis into mastocytoma, maculopapular cutaneous mastocytosis, and diffuse mastocytosis. The systemic variants in this classification are as follows: indolent systemic mastocytosis (SM), aggressive SM, SM with an associated clonal hematological non-mast cell lineage disease, mast cell leukemia, mast cell sarcoma, and extracutaneous mastocytoma. The two latest systemic variants are rare. Although the course of disease is unpredictable in children, lesions generally resolve by early adulthood. In adults, however, the disease tends to persist. The goal of treatment should be to control clinical manifestations caused by the release of mast cell mediators and, in more aggressive forms of the disease, to reduce mast cell burden. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  4. Management around invasive procedures in mastocytosis : An update

    NARCIS (Netherlands)

    Hermans, Maud A. W.; Arends, Nicolette J. T.; van Wijk, Roy Gerth; van Hagen, P. Martin; Kluin-Nelemans, Hanneke C.; Elberink, Hanneke N. G. Oude; Pasmans, Suzanne G. M. A.; van Daele, Paul L. A.

    2017-01-01

    Objective: Mastocytosis is a chronic hematologic disorder that is characterized by the accumulation of aberrant mast cells and typically involves the skin and/or bone marrow. Patients with mastocytosis are at increased risk of anaphylaxis. Based on theoretical assumptions, medical procedures

  5. Proposed diagnostic algorithm for patients with suspected mastocytosis

    DEFF Research Database (Denmark)

    Valent, P; Escribano, L; Broesby-Olsen, S

    2014-01-01

    Mastocytosis is an emerging differential diagnosis in patients with more or less specific mediator-related symptoms. In some of these patients, typical skin lesions are found and the diagnosis of mastocytosis can be established. In other cases, however, skin lesions are absent, which represents a...

  6. [Cutaneous mastocytosis: A case report].

    Science.gov (United States)

    Zegpi-Trueba, María Soledad; Hasbún-Acuña, Paula; Berroeta-Mauriziano, Daniela

    2016-01-01

    Mastocytosis represents a group of diseases characterised by an excesive accumulation of mastocytes in one or multiple tissues. It can affect only the skin, or have a systemic involvement. It has a low prevalence, and the prognosis is benign in children. To report a case of urticaria pigmentosa as a subtype of cutaneous mastocytosis, and present a literature review focused on clinical findings, diagnosis and initial basic management. A child of six months of age presenting with multiple blemishes and light brown papules located on the trunk, arms and legs. The symptoms were compatible with urticaria pigmentosa, and was confirmed by biopsy. Tests to rule out systemic involvement were requested. The patient was treated with general measures, education, and antihistamines, with favourable results. Cutaneous mastocytosis is a rare disease with a good prognosis. In childhood general measures and education are usually enough to obtain favourable results. Histamine H1 antagonists are the first line drug treatment. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Mastocytosis

    Directory of Open Access Journals (Sweden)

    Sandra Nora González-Díaz

    2015-02-01

    Full Text Available Mastocytosis is one of the eight subcategories of the myeloproliferative neoplasms of the classification of lymphoid and hematopoietic tissues’ tumors of 2008 of World Health Organization; it is an heterogeneous group of myeloproliferative diseases characterized by the excessive proliferation of atypical mastocytes in morphological and immunophenotype terms, besides the cumulus of these cells in one or several organs or tissues, including skin, bone marrow, liver, spleen and lymph nodes.

  8. Review papers The role of KIT gene mutations in pathogenesis of pediatric mastocytosis

    Directory of Open Access Journals (Sweden)

    Joanna Dawicka

    2015-03-01

    Full Text Available Mastocytosis is characterized by excessive proliferation and accumulation of mast cells in skin and/or other organs. Two forms of the disease, cutaneous and systemic mastocytosis, differ significantly in symptomatology and clinical course. KIT mutations play an important role in the pathogenesis of the disease. The presence of p.D816V KIT mutation was detected in the vast majority of adults with systemic mastocytosis. The role of KIT mutations in childhood-onset mastocytosis remains a matter of discussion. More recent studies have shown that cutaneous mastocytosis, which is the most common clinical manifestation of the disease in children, has a genetic background. In contrast to adults, different types of KIT mutations have been described in pediatric and familial mastocytosis. The understanding of the molecular mechanisms in mastocytosis enables targeted therapy using tyrosine kinase inhibitors.

  9. Systemic mastocytosis: A rare cause of non-cirrhotic portal hypertension.

    Science.gov (United States)

    Martins, Cláudio; Teixeira, Cristina; Ribeiro, Suzane; Trabulo, Daniel; Cardoso, Cláudia; Mangualde, João; Freire, Ricardo; Gamito, Élia; Alves, Ana Luísa; Cremers, Isabelle; Alves, Cecília; Neves, Anabela; Oliveira, Ana Paula

    2016-07-28

    Mastocytosis is a clonal neoplastic disorder of the mast cells (MC) that can be limited to the skin (cutaneous mastocytosis) or involve one or more extracutaneous organs (systemic mastocytosis). The clinical manifestations of mastocytosis are heterogeneous ranging from indolent disease with a long-term survival to a highly aggressive neoplasm with survival of about 6 mo. Although liver involvement in aggressive systemic mastocytosis (ASM) is relatively common, the development of portal hypertension with or without cirrhosis is rare. We report a case of ASM without skin involvement in a 72-year-old caucasian male who presented with non-cirrhotic portal hypertension based on clinical, analytical, imagiological and endoscopic findings. Given the hematological picture, the correct diagnosis was established based on ancillary tests for MC using bone marrow aspirates and biopsy. Extensive involvement of the liver and gastrointestinal tract was histologically documented. The disease progressed rapidly and severe pancytopenia and recurrent upper gastrointestinal bleeding became the dominant problem. This case illustrates the challenge in establishing a diagnosis of ASM especially when the clinical picture is atypical and without skin involvement. Gastroenterologists should consider infiltrative disease, particularly systemic mastocytosis, as a differential diagnosis in a clinical case of portal hypertension of unknown etiology.

  10. Coexistence of two types of clinical lesions in childhood-onset mastocytosis

    Directory of Open Access Journals (Sweden)

    Lidia Pérez-Pérez

    2011-01-01

    Full Text Available The vast majority of mastocytosis appear in childhood, urticaria pigmentosa (UP and mastocytomas being the most common types. Terms such as "xanthelasmoid mastocytosis", "pseudoxanthomatous mastocytosis" or "nodular mastocytosis" have been introduced in the literature to describe the presence of yellowish papular or nodular lesions. We describe two children with cutaneous mastocytosis showing yellowish lesions in combination with other skin lesions. A 10-year-old girl presented with asymptomatic lesions in her vulva at birth, and developed brownish macules on her trunk years after. An eight- year-old boy presented with multiple yellowish papular lesions on his trunk, neck and limbs coexisting with a few clinically anetodermic lesions. No systemic involvement was found and the skin biopsy confirmed a cutaneous mastocytosis in both cases. The two patients are currently asymptomatic and are being periodically followed up. Mastocytoses may show a variety of clinical lesions, sometimes leading to misdiagnosis. Although there are previous reports, involvement of the mucosae and secondary anetoderma are not common findings in cutaneous mastocytoses. We consider that cutaneous manifestations of mastocytoses compose a clinical spectrum, thus explaining the coexistence of different clinical lesions and the development of uncommon presentations.

  11. Case-control cohort study of patients' perceptions of disability in mastocytosis.

    Directory of Open Access Journals (Sweden)

    Olivier Hermine

    Full Text Available BACKGROUND: Indolent forms of mastocytosis account for more than 90% of all cases, but the types and type and severity of symptoms and their impact on the quality of life have not been well studied. We therefore performed a case-control cohort study to examine self-reported disability and impact of symptoms on the quality of life in patients with mastocytosis. METHODOLOGY/PRINCIPAL FINDINGS: In 2004, 363 mastocytosis patients and 90 controls in France were asked to rate to their overall disability (OPA score and the severity of 38 individual symptoms. The latter was used to calculate a composite score (AFIRMM score. Of the 363 respondents, 262 were part of an ongoing pathophysiological study so that the following data were available: World Health Organization classification, standard measures of physical and psychological disability, existence of the D816V KIT mutation, and serum tryptase level. The mean OPA and AFIRMM scores and the standard measures of disability indicated that most mastocytosis patients suffer from disabilities due to the disease. Surprisingly, the patient's measurable and perceived disabilities did not differ according to disease classification or presence or absence of the D816V KIT mutation or an elevated (> or = 20 ng/mL serum tryptase level. Also, 32 of the 38 AFIRMM symptoms were more common in patients than controls, but there were not substantial differences according to disease classification, presence of the D816V mutation, or the serum tryptase level. CONCLUSIONS: On the basis of these results and for the purposes of treatment, we propose that mastocytosis be first classified as aggressive or indolent and that indolent mastocytosis then be categorized according to the severity of patients' perceived symptoms and their impact on the quality of life. In addition, it appears that mastocytosis patients suffer from more symptoms and greater disability than previously thought, that mastocytosis may therefore be under

  12. Phenotypic and genotypic characteristics of mastocytosis according to the age of onset.

    Directory of Open Access Journals (Sweden)

    Fanny Lanternier

    Full Text Available Adult's mastocytosis is usually associated with persistent systemic involvement and c-kit 816 mutation, while pediatrics disease is mostly limited to the skin and often resolves spontaneously. We prospectively included 142 adult patients with histologically proven mastocytosis. We compared phenotypic and genotypic features of adults patients whose disease started during childhood (Group 1, n = 28 with those of patients whose disease started at adult's age (Group 2, n = 114. Genotypic analysis was performed on skin biopsy by sequencing of c-kit exons 17 and 8 to 13. According to WHO classification, the percentage of systemic disease was similar (75 vs. 73% in 2 groups. C-kit 816 mutation was found in 42% and 77% of patients in groups 1 and 2, respectively (p<0.001. 816 c-kit mutation was associated with systemic mastocytosis in group 2 (87% of patients with systemic mastocytosis vs. 45% with cutaneous mastocytosis, p = 0.0001. Other c-kit activating mutations were found in 23% of patients with mastocytosis' onset before the age of 5, 0% between 6 and 15 years and 2% at adults' age (p<0.001. In conclusion, pathogenesis of mastocytosis significantly differs according to the age of disease's onset. Our data may have major therapeutic relevance when considering c-kit-targeted therapy.

  13. Update on Mastocytosis (Part 1): Pathophysiology, Clinical Features, and Diagnosis.

    Science.gov (United States)

    Azaña, J M; Torrelo, A; Matito, A

    2016-01-01

    Mastocytosis is a term used to describe a heterogeneous group of disorders characterized by clonal proliferation of mast cells in various organs. The organ most often affected is the skin. Mastocytosis is a relatively rare disorder that affects both sexes equally. It can occur at any age, although it tends to appear in the first decade of life, or later, between the second and fifth decades. Our understanding of the pathophysiology of mastocytosis has improved greatly in recent years, with the discovery that somatic c-kit mutations and aberrant immunophenotypic features have an important role. The clinical manifestations of mastocytosis are diverse, and skin lesions are the key to diagnosis in most patients. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  14. Mastocytosis in Pregnancy

    Directory of Open Access Journals (Sweden)

    Ilknur Col Madendag

    2010-06-01

    Conclusion: Pregnant women with mastocytosis should be treated symptomatically and should avoid factors that may exacerbate symptoms of disease. Clinicians should be aware of preterm labor during pregnancy. As a preventive measure, resuscitation equipment should be available during the labor, delivery and postpartum period to treat unanticipated hypotension and shock.

  15. European Competence Network on Mastocytosis (ECNM): 10-year jubilee, update, and future perspectives.

    Science.gov (United States)

    Valent, Peter; Arock, Michel; Bonadonna, Patrizia; Brockow, Knut; Broesby-Olsen, Sigurd; Escribano, Luis; Gleixner, Karoline V; Grattan, Clive; Hadzijusufovic, Emir; Hägglund, Hans; Hermine, Olivier; Horny, Hans-Peter; Kluin-Nelemans, Hanneke C; Maurer, Marcus; Niedoszytko, Marek; Nedoszytko, Boguslaw; Nilsson, Gunnar; Oude-Elberink, Hanneke N G; Orfao, Alberto; Radia, Deepti; Reiter, Andreas; Siebenhaar, Frank; Sotlar, Karl; Sperr, Wolfgang R; Triggiani, Massimo; VanDoormaal, Jaap J; Várkonyi, Judit; Yavuz, Selim; Hartmann, Karin

    2012-12-01

    The European Competence Network on Mastocytosis (ECNM) was initiated in 2002 as a multidisciplinary and multinational cooperative approach to increase awareness and to improve diagnosis and therapy of mastocytosis. The network is composed of local centers, physicians, and scientists who have dedicated their work to patients with mastocytosis. A strategic goal of the ECNM is to provide the best available information about the disease to patients and physicians. During the past 10 years, the ECNM has expanded to various countries and contributed successfully to the development of markers, definitions, and standards in the field of mastocytosis. Members of the ECNM organized Annual Meetings in Europe and two Working Conferences on Mastocytosis in Vienna (in 2005 and 2010), and initiated and supported several preclinical and clinical trials. In all these activities, representatives of the ECNM cooperate closely with their US colleagues, with patient-organizations in Europe and in the USA, and with other scientific networks. The ECNM also launched a mastocytosis registry that has been activated in 2012. Using the central database of this registry, cooperative multicenter studies, which should include sufficient numbers of patients and robust evaluations, will be conducted. These studies will increase our knowledge about optimal management and therapy of patients with mastocytosis in the future.

  16. Systemic mastocytosis: Case report with literature review

    Directory of Open Access Journals (Sweden)

    Mitrović Mirjana

    2012-01-01

    Full Text Available Introduction. Mastocytosis is a clonal neoplastic disorder of the mast cells. The clinical signs and symptoms of mastocytosis are heterogeneous ranging from indolent disease with a longterm survival to a highly aggressive neoplasm with survival of about 6 months. Systemic mastocytosis (SM is characterized by mastocyte infiltration of one or more organs, with or without skin involvment. Case Outline. The presented patient presents a highly challenging diagnostic and therapeutic case. A 46-year-old man was referred to our Centre due to the 7-year-long history of hepatosplenomegaly and mild thrombocytopenia. Ultrasound examination showed hepatosplenomegaly (liver 170 mm; spleen 200 mm, platelet count was 90Č109/L, serum tryptase level was elevated and bone marrow biopsy showed infiltration with mast cells (CD117, CD25 and mast cell tryptase positive. Our patient was diagnosed with aggressive systemic mastocytosis (SM according to WHO Classification (2008, although the clinical course of the disease was indolent, without complications for more than 7 years. Because of the ‘intermediate’ course, this patient was referred to as smouldering or intermediate SM and was not treated with cytostatics. Conclusion. Utilizing the established criteria, indolent SM can be discriminated from the aggressive subvariants of SM in most cases. However, a small group of patients, like our case belongs to the „grey zone“. Therapeutic approach to these patients is individual and prognosis is uncertain.

  17. Systemic mastocytosis in a patient with polycythemia vera treated with radioactive phosphorus

    International Nuclear Information System (INIS)

    Eagan, J.W. Jr.; Baughman, K.L.; Miller, S.; Conley, C.L.; Eggleston, J.C.

    1977-01-01

    Systemic mastocytosis occurred as a fatal event in a patient with long-standing polycythemia vera. The patient had been treated over the course of 21 yr with radioactive phosphorus. Possible relationships between mastocytosis and polycythemia vera, and also between mastocytosis and treatment with ionizing radiation, are discussed. Histopathologic and electron microscopic findings are illustrated. Difficulties in establishing the diagnosis of mast cell disease in this setting are also described

  18. Radiological contribution to skeletal changes in systemic mastocytosis - urticaria pigmentosa

    Energy Technology Data Exchange (ETDEWEB)

    Schratter, M.; Canigiani, G.; Schoenbauer, C.; Mach, K.

    1983-11-01

    Three patients are demonstrated suffering from systemic mastocytosis with skin and skeletal involvement. History, clinical and radiological results are reported. After a brief analysis of the pathogenetic mechanism, the radiological findings on the skeletal system in systemic mastocytosis are discussed. Finally, roentgenological differential diagnosis of the osseous lesions is explained.

  19. Gene expression analysis predicts insect venom anaphylaxis in indolent systemic mastocytosis

    NARCIS (Netherlands)

    Niedoszytko, M.; Bruinenberg, M.; van Doormaal, J. J.; de Monchy, J. G. R.; Nedoszytko, B.; Koppelman, G. H.; Nawijn, M. C.; Wijmenga, C.; Jassem, E.; Oude Elberink, J. N. G.

    P>Background: Anaphylaxis to insect venom (Hymenoptera) is most severe in patients with mastocytosis and may even lead to death. However, not all patients with mastocytosis suffer from anaphylaxis. The aim of the study was to analyze differences in gene expression between patients with indolent

  20. Cutaneous and gastrointestinal symptoms in two patients with systemic mastocytosis successfully treated with omalizumab

    DEFF Research Database (Denmark)

    Lieberoth, Sofie; Thomsen, Simon Francis

    2015-01-01

    The pathogenesis of mastocytosis is not well defined and thus treatment remains challenging and remains on a palliative basis. We present two cases (a 48-year-old woman and a 57-year-old man) with indolent systemic mastocytosis in whom omalizumab (anti-IgE) reduced gastrointestinal and cutaneous...... symptoms significantly. This observation provides additional insight into the effects of omalizumab on systemic mastocytosis....

  1. Mastocytosis and insect venom allergy : diagnosis, safety and efficacy of venom immunotherapy

    NARCIS (Netherlands)

    Niedoszytko, M.; de Monchy, J.; van Doormaal, J. J.; Jassem, E.; Oude Elberink, J. N. G.

    The most important causative factor for anaphylaxis in mastocytosis are insect stings. The purpose of this review is to analyse the available data concerning prevalence, diagnosis, safety and effectiveness of venom immunotherapy (VIT) in mastocytosis patients. If data were unclear, authors were

  2. Association of paediatric mastocytosis with a polymorphism resulting in an amino acid substitution (M541L) in the transmembrane domain of c-KIT.

    Science.gov (United States)

    Foster, R; Byrnes, E; Meldrum, C; Griffith, R; Ross, G; Upjohn, E; Braue, A; Scott, R; Varigos, G; Ferrao, P; Ashman, L K

    2008-11-01

    The receptor tyrosine kinase c-KIT plays a key role in normal mast cell development. Point mutations in c-KIT have been associated with sporadic or familial mastocytosis. Two unrelated pairs of apparently identical twins affected by cutaneous mastocytosis attending the Mastocytosis Clinic at the Royal Children's Hospital, Melbourne, provided an opportunity to assess the possible contribution of c-KIT germline mutations or polymorphisms in this disease. Tissue biopsy, blood and/or buccal swab specimens were collected from 10 children with mastocytosis. To detect germline mutations/polymorphisms in c-KIT, we studied all coding exons by denaturing high pressure liquid chromatography. Exons showing mismatches were examined by direct sequencing. The influence of the substitution identified was further examined by expressing the variant form of c-KIT in factor-dependent FDC-P1 cells. In both pairs of twins, a heterozygous ATG to CTG transition in codon 541 was observed, resulting in the substitution of a methionine residue in the transmembrane domain by leucine (M541L). In each case, one parent was also heterozygous for this allele. Expression of M541L KIT in FDC-P1 cells enabled them to grow in human KIT ligand (stem cell factor, SCF) but did not confer factor independence. Compared with cells expressing wild-type KIT at a similar level, M541L KIT-expressing cells displayed enhanced growth at low levels of SCF, and heightened sensitivity to the KIT inhibitor, imatinib mesylate. The data suggest that the single nucleotide polymorphism resulting in the substitution M541L may predispose to paediatric mastocytosis.

  3. ANAPHYLACTOID SHOCK FOLLOWING HYMENOPTERA STING AS A PRESENTING SYMPTOM OF SYSTEMIC MASTOCYTOSIS

    NARCIS (Netherlands)

    KORS, JW; VANDOORMAAL, JJ; DEMONCHY, JGR

    Systemic mastocytosis is a rare and chronic disorder characterized by a pathologically increased number of mast cells in various tissues and overproduction of mast cell mediators. From a group of 1 5 patients (I 0 females, 5 males) with systemic mastocytosis five female patients presented with a

  4. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  5. Cutaneous manifestations in patients with mastocytosis: Consensus report of the European Competence Network on Mastocytosis; the American Academy of Allergy, Asthma & Immunology; and the European Academy of Allergology and Clinical Immunology.

    Science.gov (United States)

    Hartmann, Karin; Escribano, Luis; Grattan, Clive; Brockow, Knut; Carter, Melody C; Alvarez-Twose, Ivan; Matito, Almudena; Broesby-Olsen, Sigurd; Siebenhaar, Frank; Lange, Magdalena; Niedoszytko, Marek; Castells, Mariana; Oude Elberink, Joanna N G; Bonadonna, Patrizia; Zanotti, Roberta; Hornick, Jason L; Torrelo, Antonio; Grabbe, Jürgen; Rabenhorst, Anja; Nedoszytko, Boguslaw; Butterfield, Joseph H; Gotlib, Jason; Reiter, Andreas; Radia, Deepti; Hermine, Olivier; Sotlar, Karl; George, Tracy I; Kristensen, Thomas K; Kluin-Nelemans, Hanneke C; Yavuz, Selim; Hägglund, Hans; Sperr, Wolfgang R; Schwartz, Lawrence B; Triggiani, Massimo; Maurer, Marcus; Nilsson, Gunnar; Horny, Hans-Peter; Arock, Michel; Orfao, Alberto; Metcalfe, Dean D; Akin, Cem; Valent, Peter

    2016-01-01

    Cutaneous lesions in patients with mastocytosis are highly heterogeneous and encompass localized and disseminated forms. Although a classification and criteria for cutaneous mastocytosis (CM) have been proposed, there remains a need to better define subforms of cutaneous manifestations in patients with mastocytosis. To address this unmet need, an international task force involving experts from different organizations (including the European Competence Network on Mastocytosis; the American Academy of Allergy, Asthma & Immunology; and the European Academy of Allergology and Clinical Immunology) met several times between 2010 and 2014 to discuss the classification and criteria for diagnosis of cutaneous manifestations in patients with mastocytosis. This article provides the major outcomes of these meetings and a proposal for a revised definition and criteria. In particular, we recommend that the typical maculopapular cutaneous lesions (urticaria pigmentosa) should be subdivided into 2 variants, namely a monomorphic variant with small maculopapular lesions, which is typically seen in adult patients, and a polymorphic variant with larger lesions of variable size and shape, which is typically seen in pediatric patients. Clinical observations suggest that the monomorphic variant, if it develops in children, often persists into adulthood, whereas the polymorphic variant may resolve around puberty. This delineation might have important prognostic implications, and its implementation in diagnostic algorithms and future mastocytosis classifications is recommended. Refinements are also suggested for the diagnostic criteria of CM, removal of telangiectasia macularis eruptiva perstans from the current classification of CM, and removal of the adjunct solitary from the term solitary mastocytoma. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  6. Systemic Mastocytosis: A Rare Case of Increased Liver Stiffness

    Directory of Open Access Journals (Sweden)

    Stefanie Adolf

    2012-01-01

    Full Text Available Assessment of liver stiffness (LS by transient elastography (Fibroscan has significantly improved the noninvasive diagnosis of liver fibrosis. We here report on a 55-year-old patient with drastically increased LS due to previously unknown systemic mastocytosis. The patient initially presented with increased weight loss, nocturnal pruritus, increased transaminases, bilirubinemia, and thrombocytopenia. Abdominal ultrasound showed ascites, hepatomegaly, and splenomegaly. In addition, LS was 75 kPa (IQR 0 kPa clearly exceeding the cut-off value for F4 cirrhosis of 12.5 kPa. However, histological analysis of the liver specimen indicated liver involvement by systemic mastocytosis and excluded liver cirrhosis. An additional CT scan detected disseminated bone lesions. After three months of treatment with Midostaurin, LS slightly decreased down to 31.9 kPa (IQR 8.3 kPa. This case illustrates that diffused sinusoidal neoplastic infiltrates are a pitfall in the non-invasive diagnosis of liver cirrhosis. In conclusion, refined clinical algorithms for increased LS should also include mastocytosis in addition to inflammation, congestion, and biliary obstruction.

  7. The Mastocytosis Society survey on mast cell disorders: patient experiences and perceptions.

    Science.gov (United States)

    Jennings, Susan; Russell, Nancy; Jennings, Blair; Slee, Valerie; Sterling, Lisa; Castells, Mariana; Valent, Peter; Akin, Cem

    2014-01-01

    Mast cell diseases include mastocytosis and mast cell activation syndromes, some of which have been shown to involve clonal defects in mast cells that result in abnormal cellular proliferation or activation. Numerous clinical studies of mastocytosis have been published, but no population-based comprehensive surveys of patients in the United States have been identified. Few mast cell disease specialty centers exist in the United States, and awareness of these mast cell disorders is limited among nonspecialists. Accordingly, information concerning the experiences of the overall estimated population of these patients has been lacking. To identify the experiences and perceptions of patients with mastocytosis, mast cell activation syndromes, and related disorders, The Mastocytosis Society (TMS), a US based patient advocacy, research, and education organization, conducted a survey of its members and other people known or suspected to be part of this patient population. A Web-based survey was publicized through clinics that treat these patients and through TMS's newsletter, Web site, and online blogs. Both online and paper copies of the questionnaire were provided, together with required statements of consent. The first results are presented for 420 patients. These results include demographics, diagnoses, symptoms, allergies, provoking factors of mast cell symptoms, and disease impact. Patients with mastocytosis and mast cell activation syndromes have provided clinical specialists, collaborators, and other patients with information to enable them to explore and deepen their understanding of the experiences and perceptions of people coping with these disorders. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  8. A French National Survey on Clotting Disorders in Mastocytosis.

    Science.gov (United States)

    Carvalhosa, Ana B; Aouba, Achille; Damaj, Gandhi; Canioni, Danielle; Brouzes, Chantal; Gyan, Emmanuel; Durupt, Stéphane; Durieu, Isabelle; Cathebras, Pascal; Costédoat-Chalumeau, Nathalie; Launay, David; Pilmis, Benoit; Barete, Stephane; Frenzel, Laurent; Lortholary, Olivier; Hermine, Olivier; Hermans, Cedric; Chandesris, Marie-Olivia

    2015-10-01

    Mastocytosis is characterized by a clonal mast cell proliferation with organ infiltration and uncontrolled degranulation. Although not characteristic and poorly explained, some patients develop clotting abnormalities. We retrospectively identified patients with established diagnosis of mastocytosis and related clotting abnormalities (clinical and/or biological) using the national French Reference Centre for Mastocytosis database. From our cohort of 14 adult patients with clotting abnormalities (median age 46 years [range 26-75]), 4 had a presentation suggestive of a primary hemostasis disorder alone (by their symptoms and/or abnormal clotting tests [PFA, von Willebrand's disease [vWD] screening]) and 10 had a laboratory impairment of secondary hemostasis. Among these, 7 had bleeds characteristic of a coagulation cascade disorder (severe/life-threatening in 5 and mild in 2 patients). Clotting abnormalities were of variable severity, typically related to intense crisis of degranulation, such as anaphylactic reactions, and/or to severe organ infiltration by mast cells. Importantly, classical hemostatic management with platelet transfusion, fresh frozen plasma, or vitamin K infusions was unsuccessful, as opposed to the use of agents inhibiting mast cell activity, particularly steroids. This illustrates the crucial role of mast cell mediators such as tryptase and heparin, which interfere both with primary (mainly via inhibition of von Willebrand factor) and secondary hemostasis. There was interestingly an unusually high number of aggressive mastocytosis (particularly mast cell leukemia) and increased mortality in the group with secondary hemostasis disorders (n = 5, 36% of the whole cohort). Mast cell degranulation and/or high tumoral burden induce both specific biologic antiaggregant and anticoagulant states with a wide clinical spectrum ranging from asymptomatic to life-threatening bleeds. Hemostatic control is achieved by mast cell inhibitors such as steroids.

  9. Systemic mastocytosis with polyostotic bone involvement abstract

    International Nuclear Information System (INIS)

    Melendez, Patricia; Elvira, Castro; Neira, Fabian

    2004-01-01

    Mastocytosis is a heterogeneous group of diseases characterized by the proliferation of mast cells and their subsequent accumulation in one or more organ systems. the signs and symptoms of the mast cell disease are varied, depending on the localization of the mast cell in different organs and on the local and systemic effects of the mediators released by these cells. Cutaneous mast cell disease is the most common one, either localized in the skin or associated with extra cutaneous organs. Most patients have a favorable outcome: their lesions regress spontaneously, remain stable, or are only slowly progressive. In others, the mast cell proliferation is systemic, with or without evidence of skin infiltration. Mast cell leukemia, mast cell sarcoma, and hematological malignancy are rare. The case considered in this paper is a 52-year-old man's with multiple lytic osseous lesions due to a systemic mastocytosis

  10. Apparent third patient with cutaneous mastocytosis, microcephaly, conductive hearing loss, and microtia.

    Science.gov (United States)

    Salpietro, Carmelo Damiano; Briuglia, Silvana; Cutrupi, Maria Concetta; Gallizzi, Romina; Rigoli, Luciana; Dallapiccola, Bruno

    2009-10-01

    Mastocytosis refers to a heterogeneous group of rare disorders characterized by an abnormal accumulation of mast cells in one or more organ systems. Cutaneous mastocytosis (CM) is the most frequent form in children and is characterized by hyperpigmented macules or papules symmetrically distributed over the trunk, and less so over the limbs, neck, and scalp. Two published articles have reported on unrelated girls presenting with mastocytosis, microcephaly, hearing loss, and hypotonia. Based on the original observation, this disorder was defined as CM with short stature, conductive hearing loss, and microtia (OMIM 248910). Here we report on a girl with similar manifestations who corroborates the existence of this rare disorder. CM, microcephaly, microtia, and/or hearing loss are the minimal diagnostic criteria. All the known patients were sporadic, but parental consanguinity in the first case argues for a possible autosomal-recessive inheritance.

  11. Advanced imaging of skeletal manifestations of systemic mastocytosis

    International Nuclear Information System (INIS)

    Fritz, J.; Fishman, E.K.; Carrino, J.A.; Horger, M.S.

    2012-01-01

    Systemic mastocytosis comprises a group of clonal disorders of the mast cell that most commonly involves the skeletal system. Imaging can be helpful in the detection and characterization of the osseous manifestations of this disease. While radiography and bone scans are frequently used for this assessment, low-dose multidetector computed tomography and magnetic resonance imaging can be more sensitive for the detection of marrow involvement and for the demonstration of the various disease patterns. In this article, we review the pathophysiological and clinical features of systemic mastocytosis, discuss the role of imaging for staging and management, and illustrate the various cross-sectional imaging appearances. Awareness and knowledge of the imaging features of this disorder will increase the accuracy of image interpretation and can contribute important information for management decisions. (orig.)

  12. Advanced imaging of skeletal manifestations of systemic mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Fishman, E.K.; Carrino, J.A. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Horger, M.S. [Eberhard-Karls-University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2012-08-15

    Systemic mastocytosis comprises a group of clonal disorders of the mast cell that most commonly involves the skeletal system. Imaging can be helpful in the detection and characterization of the osseous manifestations of this disease. While radiography and bone scans are frequently used for this assessment, low-dose multidetector computed tomography and magnetic resonance imaging can be more sensitive for the detection of marrow involvement and for the demonstration of the various disease patterns. In this article, we review the pathophysiological and clinical features of systemic mastocytosis, discuss the role of imaging for staging and management, and illustrate the various cross-sectional imaging appearances. Awareness and knowledge of the imaging features of this disorder will increase the accuracy of image interpretation and can contribute important information for management decisions. (orig.)

  13. Skin mastocytosis, hearing loss and mental retardation

    NARCIS (Netherlands)

    Hennekam, R. C.; Beemer, F. A.

    1992-01-01

    A girl with skin mastocytosis, hearing loss, microcephaly, mild dysmorphic features and severe mental retardation is described. The symptoms of the child resemble those reported in 1990 by Wolach et al. in another patient sufficiently to suspect the same entity in both. Inheritance may be autosomal

  14. FDG-PET/CT findings in systemic mastocytosis: a French multicentre study

    Energy Technology Data Exchange (ETDEWEB)

    Djelbani-Ahmed, S. [Assistance Publique - Hopitaux de Paris (APHP), Department of Nuclear Medicine, Avicenne Hospital, Bobigny (France); Paris 13 University, Sorbonne Paris Cite, Bobigny (France); Chandesris, M.O. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (France); Necker Children' s Hospital, APHP, Department of Haematology, Paris (France); Paris Descartes University, Sorbonne Paris Cite, Imagine Institute, Paris (France); Mekinian, A.; Fain, O. [Saint Antoine Hospital, Department of Internal Medicine and Inflammation-Immunopathology-Biotherapy Department (DHU i2B), AP-HP, Paris (France); Canioni, D. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (France); Paris Descartes University, Sorbonne Paris Cite, Imagine Institute, Paris (France); Necker Children' s Hospital, APHP, Department of Pathology, Paris (France); Brouzes, C. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (France); Paris Descartes University, Sorbonne Paris Cite, Imagine Institute, Paris (France); Necker Children' s Hospital, APHP, Laboratory of Haematology, Paris (France); Hanssens, K. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (France); Aix-Marseille University, INSERM U1068, Centre de Recherche en Cancerologie de Marseille (Signaling, Hematopoiesis and Mechanism of Oncogenesis), Paoli Calmettes Institute, Marseille (France); Pop, G.; Eder, V. [Assistance Publique - Hopitaux de Paris (APHP), Department of Nuclear Medicine, Avicenne Hospital, Bobigny (France); Durieu, I.; Durupt, S. [Universite de Lyon, Department of Internal and Vascular Medicine, Hospices Civils de Lyon, Groupe Hopitalier Sud, Pierre-Benite (France); Grosbois, B.; Besnard, S. [Rennes University Hospital, Department of Internal Medicine, Rennes (France); Tournilhac, O. [Clermont-Ferrand University Hospital, Department of Internal Medicine, Clermont-Ferrand (France); Beyne-Rauzy, O. [Purpan University Hospital, Department of Internal Medicine, Toulouse (France); Agape, P. [Saint-Denis University Hospital, Department of Oncology and Haematology, Saint-Denis de la Reunion (France); Delmer, A. [Reims University Hospital, Department of Haematology, Reims (France); Ranta, D. [Brabois University Hospital, Department of Haematology, Vandoeuvre les Nancy (France); Jeandel, P.Y. [Nice University Hospital, Department of Internal Medicine, Nice (France); Georgin-Lavialle, S. [Tenon Hospital, Department of Internal Medicine, Paris (France); Frenzel, L.; Hermine, O. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (FR); Necker Children' s Hospital, APHP, Department of Haematology, Paris (FR); Paris Descartes University, Sorbonne Paris Cite, Imagine Institute, Paris (FR); Damaj, G. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (FR); Caen University Hospital, Department of Haematology, Caen (FR); Lortholary, O. [Necker Children' s Hospital, APHP, French Reference center for Mastocytosis (Centre de Reference des Mastocytoses, CEREMAST), Paris (FR); Paris Descartes University, Sorbonne Paris Cite, Imagine Institute, Paris (FR); Pasteur Institute, Department of Infectious Diseases and Tropical Medicine, Necker Children' s Hospital, APHP, Paris (FR); Soussan, M. [Assistance Publique - Hopitaux de Paris (APHP), Department of Nuclear Medicine, Avicenne Hospital, Bobigny (FR); Paris 13 University, Sorbonne Paris Cite, Bobigny (FR)

    2015-12-15

    Mastocytosis is a clonal haematological disease characterized by uncontrolled proliferation and the activation of mast cells. The value of FDG-PET/CT (FDG-PET) in mastocytosis has yet to be determined. We retrospectively identified patients with an established diagnosis of systemic mastocytosis (SM), according to the WHO criteria, who underwent PET using the French Reference Centre for Mastocytosis database. Semi-quantitative and visual analysis of FDG-PET was performed and compared to the clinico-biological data. Our cohort included 19 adult patients, median age 65 years [range 58-74], including three with smouldering SM (SSM), three with aggressive SM (ASM), 10 with an associated clonal haematological non-mast-cell lineage disease (SM-AHNMD), and three with mast cell sarcoma (MCS). FDG-PET was performed at the time of the SM diagnosis (15/19), to evaluate lymph node (LN) activity (3/19) or the efficacy of therapy (1/19). FDG uptake was observed in the bone marrow (BM) (9/19, 47 %), LN (6/19, 32 %), spleen (12/19, 63 %), or liver (1/19, 5 %). No significant FDG uptake was observed in the SSM and ASM patients. A pathological FDG uptake was observed in the BM of 6/10 patients with SM-AHNMD, appearing as diffuse and homogeneous, and in the LN of 5/10 patients. All 3 MCS patients showed intense and multifocal BM pathological uptake, mimicking metastasis. No correlation was found between the FDG-PET findings and serum tryptase levels, BM mast cell infiltration percentage, and CD30 and CD2 expression by mast cells. FDG uptake does not appear to be a sensitive marker of mast cell activation or proliferation because no significant FDG uptake was observed in most common forms of mastocytosis (notably purely aggressive SM). However, pathological FDG uptake was observed in the SM-AHNMD and in MCS cases, suggesting a role of FDG-PET in their early identification and as a tool of therapeutic assessment in this subgroup of patients. (orig.)

  15. FDG-PET/CT findings in systemic mastocytosis: a French multicentre study

    International Nuclear Information System (INIS)

    Djelbani-Ahmed, S.; Chandesris, M.O.; Mekinian, A.; Fain, O.; Canioni, D.; Brouzes, C.; Hanssens, K.; Pop, G.; Eder, V.; Durieu, I.; Durupt, S.; Grosbois, B.; Besnard, S.; Tournilhac, O.; Beyne-Rauzy, O.; Agape, P.; Delmer, A.; Ranta, D.; Jeandel, P.Y.; Georgin-Lavialle, S.; Frenzel, L.; Hermine, O.; Damaj, G.; Lortholary, O.; Soussan, M.

    2015-01-01

    Mastocytosis is a clonal haematological disease characterized by uncontrolled proliferation and the activation of mast cells. The value of FDG-PET/CT (FDG-PET) in mastocytosis has yet to be determined. We retrospectively identified patients with an established diagnosis of systemic mastocytosis (SM), according to the WHO criteria, who underwent PET using the French Reference Centre for Mastocytosis database. Semi-quantitative and visual analysis of FDG-PET was performed and compared to the clinico-biological data. Our cohort included 19 adult patients, median age 65 years [range 58-74], including three with smouldering SM (SSM), three with aggressive SM (ASM), 10 with an associated clonal haematological non-mast-cell lineage disease (SM-AHNMD), and three with mast cell sarcoma (MCS). FDG-PET was performed at the time of the SM diagnosis (15/19), to evaluate lymph node (LN) activity (3/19) or the efficacy of therapy (1/19). FDG uptake was observed in the bone marrow (BM) (9/19, 47 %), LN (6/19, 32 %), spleen (12/19, 63 %), or liver (1/19, 5 %). No significant FDG uptake was observed in the SSM and ASM patients. A pathological FDG uptake was observed in the BM of 6/10 patients with SM-AHNMD, appearing as diffuse and homogeneous, and in the LN of 5/10 patients. All 3 MCS patients showed intense and multifocal BM pathological uptake, mimicking metastasis. No correlation was found between the FDG-PET findings and serum tryptase levels, BM mast cell infiltration percentage, and CD30 and CD2 expression by mast cells. FDG uptake does not appear to be a sensitive marker of mast cell activation or proliferation because no significant FDG uptake was observed in most common forms of mastocytosis (notably purely aggressive SM). However, pathological FDG uptake was observed in the SM-AHNMD and in MCS cases, suggesting a role of FDG-PET in their early identification and as a tool of therapeutic assessment in this subgroup of patients. (orig.)

  16. Systemic mastocytosis--a systematic review

    DEFF Research Database (Denmark)

    Andersen, Christen Lykkegaard; Kristensen, Thomas Kielsgaard; Severinsen, Marianne Tang

    2012-01-01

    The mast cell lives a hidden life, but it is implicated in several physiological reactions. Its ability to react to different stimuli impacts a variety of conditions such as asthma, atopic dermatitis, urticaria and anaphylaxis. It is not until recent decades that the evolution of the cell has bee...... described and its fascinating biology has only recently been depicted. We here give a review of systemic mastocytosis in regards to cell biology, diagnostic approaches and clinical practice....

  17. Bone scan in mastocytosis: case report

    International Nuclear Information System (INIS)

    Sy, W.M.; Bonventre, M.V.; Camera, A.

    1976-01-01

    A 45-year-old man with well-documented systemic mastocytosis showed generalized symmetric increased activity on bone imaging. These scan findings are grossly indistinguishable from those of patients with renal osteodystrophy or secondary hyperparathyroidism. The images of the hands, however, failed to show the changes observed in secondary hyperparathyroidism. The mechanism for this intense activity is thought to be due to aberrant new-bone formation

  18. Epidemiology, diagnosis, and treatment of Hymenoptera venom allergy in mastocytosis patients.

    Science.gov (United States)

    Niedoszytko, Marek; Bonadonna, Patrizia; Oude Elberink, Joanne N G; Golden, David B K

    2014-05-01

    Hymenoptera venom allergy is a typical IgE-mediated reaction caused by sensitization to 1 or more allergens of the venom, and accounts for 1.5% to 34% of all cases of anaphylaxis. Patients suffering from mastocytosis are more susceptible to the anaphylactic reactions to an insect sting. This article aims to answer the most important clinical questions raised by the diagnosis and treatment of insect venom allergy in mastocytosis patients. Total avoidance of Hymenoptera is not feasible, and there is no preventive pharmacologic treatment available, although venom immunotherapy reduces the risk of subsequent systemic reactions. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Diffuse cutaneous mastocytosis: analysis of 10 cases and a brief review of the literature.

    Science.gov (United States)

    Lange, M; Niedoszytko, M; Nedoszytko, B; Łata, J; Trzeciak, M; Biernat, W

    2012-12-01

    Diffuse cutaneous mastocytosis (DCM) is an extremely rare disease characterized by mast cell (MCs) infiltration of the entire skin. Little is known about the natural course of DCM. We decided to characterize clinical manifestations, the frequency of MCs mediator-related symptoms and anaphylaxis, risk of systemic mastocytosis (SM) and prognosis, based on 10 cases of DCM, the largest series published to date. Diffuse cutaneous mastocytosis, DCM was confirmed by histopathological examination of skin samples in all cases. SCORing Mastocytosis (SCORMA) Index was used to assess the intensity of DCM. The analysis of clinical symptoms and laboratory tests, including serum tryptase levels was performed. Bone marrow biopsy was done only in selected cases. Large haemorrhagic bullous variant of DCM (five cases) and infiltrative small vesicular variant (five cases) were identified. The skin symptoms appeared in age-dependent manner; blistering predominated in infancy, whereas grain-leather appearance of the skin and pseudoxanthomatous presentation developed with time. SM was not recognized in any of the patients. Mast cell mediator-related symptoms were present in all cases. Anaphylactic shock occurred in three patients. Follow-up performed in seven cases revealed slight improvement of skin symptoms, reflected by decrease of SCORMA Index in all of them. Serum tryptase levels declined with time in six cases. Diffuse cutaneous mastocytosis, DCM is a heterogeneous, severe, cutaneous disease, associated with mediator-related symptoms and risk of anaphylactic shock. Although our results suggest generally favourable prognosis, the review of the literature indicate that SM may occur. Therefore, more guarded prognosis should be given in DCM patients. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  20. KIT D816V mutation-positive cell fractions in lesional skin biopsies from adults with systemic mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Broesby-Olsen, Sigurd; Vestergaard, Hanne

    2013-01-01

    Most adults with systemic mastocytosis (SM) carry the somatic KIT D816V mutation, but the occurrence of the mutation in lesional skin remains to be characterized.......Most adults with systemic mastocytosis (SM) carry the somatic KIT D816V mutation, but the occurrence of the mutation in lesional skin remains to be characterized....

  1. Indolent Systemic Mastocytosis – a Case Report

    Directory of Open Access Journals (Sweden)

    Vujanović Ljuba

    2017-09-01

    Full Text Available Indolent systemic mastocytosis is a benign form of systemic mastocytosis characterized by an abnormal proliferation of mast cells either in the bone marrow or in numerous tissues. Case Report: A 27-year-old female patient was admitted to our department due to urticaria which started a month ago. Before the skin changes appeared, our patient suffered from a toothache, so she took various painkillers (nimesulide, ibuprofen, acetylsalicylic acid, paracetamol. During skin examination, individual hyperpigmented macules on the trunk and lower limbs were observed as incidental findings. The patient reported having them for the last two years. Darier's sign was positive. Following the examination, she was admitted due to suspected urticaria pigmentosa. Laboratory Findings: erythrocyte sedimentation rate: 9 mm/h; complete blood count, urine, blood glucose, total and direct bilirubin, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, urea, creatinine, and uric acid were within normal ranges. Electrolytes: sodium, potassium, chlorine clearance, total calcium and calcium ionized, osteocalcin, and crosslaps were within normal ranges as well. Fibrinogen: 5.57 g/l; 5-Hydroxyindoleacetic acid: 49.8 umol/dU (10.4 - 31.2. Bone densitometry, chest x-ray and upper abdomen ultrasound findings were normal. The suspected clinical diagnosis of urticaria pigmentosa was confirmed by skin biopsy. Histopathological examination of the bone marrow showed moderately increased cellularity (60 - 70%. All three types of blood cells were slightly multiplied. Focal infiltrations were found in the perivascular area, consisting of elongated, oval cells with abundant eosinophilic granular cytoplasm. The nuclei were regular, oval shaped with finely granular chromatin and inconspicuous nucleoli. No nuclear atypia was found. These cells are highly CD117-positive. This finding strongly indicated bone marrow infiltration in systemic mastocytosis. The

  2. Two patients with osteoporosis : initial presentation of systemic mastocytosis

    NARCIS (Netherlands)

    Donker, Marjolein L.; Bakker, Nicolaas A.; Jaspers, Wim J. M.; Verhage, Albert H.

    In two patients with osteoporosis, systemic mastocytosis ultimately turned out to be the underlying disease. Both patients had a history of anaphylactic reactions caused by wasp stings but did not have any skin or other symptoms. This observation reflects the need for careful history taking and

  3. Biochemical markers predictive for bone marrow involvement in systemic mastocytosis

    NARCIS (Netherlands)

    Donker, Marjolein L.; van Doormaal, Jasper J.; van Doormaal, Frederiek F.; Kluin, Philip M.; van der Veer, Eveline; de Monchy, Jan G. R.; Kema, Ido P.; Kluin-Nelemans, Hanneke C.

    Systemic mastocytosis is characterized by bone marrow involvement, which requires a bone marrow biopsy for diagnostic work-up. We questioned whether bone marrow involvement could be predicted using biochemical markers. We selected patients with various symptoms suggestive of indolent systemic

  4. Added sensitivity of component-resolved diagnosis in hymenoptera venom-allergic patients with elevated serum tryptase and/or mastocytosis

    DEFF Research Database (Denmark)

    Michel, J B; Brockow, K; Darsow, U

    2016-01-01

    BACKGROUND: Anaphylaxis caused by hymenoptera venom allergy is associated with elevation of baseline serum tryptase (sBT) and/or mastocytosis in about 5% of patients. Up to now, no information has become available on single venom allergen sIgE reactivity and the usefulness of component......-resolved approaches to diagnose this high-risk patient group. To address the component-resolved sIgE sensitization pattern and diagnostic sensitivity in hymenoptera venom-allergic patients with elevated sBT levels and/or mastocytosis, a panel of yellow jacket and honeybee venom allergens was applied on a widely used...... IgE immunoassay platform. METHODS: Fifty-three patients with mastocytosis and/or elevated sBT tryptase level and systemic reactions to hymenoptera venoms were analyzed for their IgE reactivity to recombinant yellow jacket and honeybee venom allergens by Immulite3 g. RESULTS: sIgE reactivity to Ves v...

  5. Epidemiology, Diagnosis, and Treatment of Hymenoptera Venom Allergy in Mastocytosis Patients

    NARCIS (Netherlands)

    Niedoszytko, Marek; Bonadonna, Patrizia; Oude Elberink, Joanne N. G.; Golden, David B. K.

    Hymenoptera venom allergy is a typical IgE-mediated reaction caused by sensitization to 1 or more allergens of the venom, and accounts for 1.5% to 34% of all cases of anaphylaxis. Patients suffering from mastocytosis are more susceptible to the anaphylactic reactions to an insect sting. This article

  6. Osteoporosis and Osteopathy Markers in Patients with Mastocytosis

    Directory of Open Access Journals (Sweden)

    Nilüfer Alpay Kanıtez

    2015-03-01

    Full Text Available OBJECTIVE: Osteoporosis, osteosclerosis, and lytic bone lesions have been observed in patients with systemic mastocytosis (SM. We examined bone mineral density (BMD biochemical turnover markers and serum tryptase levels in SM, which is considered a rare disease. METHODS: Seventeen adult patients (5 females, 12 males; median age: 33 years, range: 20-64 with mastocytosis were included in this study. We investigated the value of quantitative ultrasound (QUS of the calcaneus in the assessment of BMD in SM patients, as well as BMD of the lumbar spine (L1-L4, femoral neck, and distal radius using dual energy x-ray absorptiometry (DXA and plasma tryptase levels, biochemical markers of bone turnover. RESULTS: At lumbar spine L1-L4, the femoral neck, and the distal radius or as calcaneus stiffness, 12 of 17 patients had T-scores of less than -1 at least at 1 site, reflecting osteopenia. Three of 17 patients had T-scores showing osteoporosis (T-score <-2.5. There was no relationship between DXA and bone lesion severity. We also found a significant positive correlation between tryptase levels and disease severity, as well as between disease severity and pyridinoline (p<0.01 by Spearman’s test. CONCLUSION: DXA and calcaneal QUS may not be appropriate techniques to assess bone involvement in SM patients because of the effects of osteosclerosis. This study further shows that the osteoclastic marker pyridinoline is helpful in patients with severe disease activity and sclerotic bone lesions to show bone demineralization.

  7. Mastocitosis sistémica: repercusión ósea Systemic mastocytosis: bone impact

    Directory of Open Access Journals (Sweden)

    Francisco R. Spivacow

    2012-06-01

    Full Text Available La mastocitosis sistémica es una enfermedad caracterizada por acumulación de mastocitos en varios órganos, de los cuales el más afectado es la piel. La repercusión ósea de esta enfermedad es poco frecuente y en general se la asocia al desarrollo de osteoporosis secundaria con o sin fracturas óseas. Se presentan tres pacientes con lesiones características en piel de mastocitosis y diferentes manifestaciones óseas; el primer caso es una mujer de 51 años en la que se observó una variante esclerosante muy poco frecuente, con densitometría ósea en valores normales-altos y aumento de la densidad ósea observada en varias vértebras por radiografías. Una punción-biopsia de cresta ilíaca confirmó el compromiso óseo de su enfermedad de base. El segundo caso fue una mujer de 57 años que mostró signos característicos de mastocitosis sistémica con diarreas, gastritis, flushes y reacciones cutáneas particulares ante exposición a alérgenos. Se observó además grave disminución de la densidad mineral ósea tanto en columna lumbar como en cuello de fémur con parámetros bioquímicos de aumento de la resorción ósea, por lo que fue necesario tratarla con bisfosfonatos. La tercera paciente, de 67 años de edad, presentó varias fracturas vertebrales, con densitometría ósea levemente disminuida. En esta última paciente se constató una hiperplaquetosis con diagnóstico histológico de trombocitemia esencial, cuadro que suele asociarse a la mastocitosis sistémica. En definitiva, se presentan y discuten tres variantes óseas diferentes de mastocitosis sistémica.Systemic mastocytosis is a disease characterized by accumulation of mast cells in various organs of which the most affected is the skin. The bone impact of this disease is very rare and generally associated with the development of secondary osteoporosis with or without fractures. We present three cases of patients with skin mastocytosis lesions and different bone

  8. Mastocytosis and adverse reactions to biogenic amines and histamine-releasing foods : what is the evidence?

    NARCIS (Netherlands)

    Viieg-Boerstra, BJ; van der Heide, S; Elberink, JNGO; Kluin-Nelemans, JC; Dubois, AEJ

    2005-01-01

    Background: It has been suggested that normal concentrations of biogenic amines and 'histamine-releasing foods' may exacerbate symptoms in mastocytosis. The purpose of this study was to look for scientific evidence in the literature on diets restricted in biogenic amines and histamine-releasing

  9. Nonaggressive systemic mastocytosis (SM) without skin lesions associated with insect-induced anaphylaxis shows unique features versus other indolent SM.

    Science.gov (United States)

    Alvarez-Twose, Iván; Zanotti, Roberta; González-de-Olano, David; Bonadonna, Patrizia; Vega, Arantza; Matito, Almudena; Sánchez-Muñoz, Laura; Morgado, José Mário; Perbellini, Omar; García-Montero, Andrés; De Matteis, Giovanna; Teodósio, Cristina; Rossini, Maurizio; Jara-Acevedo, María; Schena, Donatella; Mayado, Andrea; Zamò, Alberto; Mollejo, Manuela; Sánchez-López, Paula; Cabañes, Nieves; Orfao, Alberto; Escribano, Luis

    2014-02-01

    Indolent systemic mastocytosis (ISM) without skin lesions (ISMs(-)) shows a higher prevalence in males, lower serum baseline tryptase levels, and KIT mutation more frequently restricted to bone marrow (BM) mast cells (MCs) than ISM with skin lesions (ISMs(+)). Interestingly, in almost one-half of ISMs(-) patients, MC-mediator release episodes are triggered exclusively by insects. We aimed to determine the clinical and laboratory features of ISMs(-) associated with insect-induced anaphylaxis (insectISMs(-)) versus other patients with ISM. A total of 335 patients presenting with MC activation syndrome, including 143 insectISMs(-), 72 ISMs(-) triggered by other factors (otherISMs(-)), 56 ISMs(+), and 64 nonclonal MC activation syndrome, were studied. Compared with otherISMs(-) and ISMs(+) patients, insectISMs(-) cases showed marked male predominance (78% vs 53% and 46%; P < .001), a distinct pattern of MC-related symptoms, and significantly lower median serum baseline tryptase levels (22.4 vs 28.7 and 45.8 μg/L; P ≤ .009). Moreover, insectISMs(-) less frequently presented BM MC aggregates (46% vs 70% and 81%; P ≤ .001), and they systematically showed MC-restricted KIT mutation. ISMs(-) patients with anaphylaxis triggered exclusively by insects display clinical and laboratory features that are significantly different from other ISM cases, including other ISMs(-) and ISMs(+) patients, suggesting that they represent a unique subgroup of ISM with a particularly low BM MC burden in the absence of adverse prognostic factors. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  10. Determination of D816V mutation in the c-kIt gene in the Slovenian patients with acute myeloid leukemia and systemic mastocytosis

    Directory of Open Access Journals (Sweden)

    Martina Fink

    2012-12-01

    Full Text Available Background: D816V mutation in the C-KIT gene is present in more than 90 % of patients with systemic mastocytosis (SM and 2–7 % of patients with acute myeloid leukemia (AML. D816V mutation is caused by the substitution of adenine with thymine at 2447 nucleotide sequence in the C-KIT gene. This nucleotide substitution causes the replacment of aspartate acid by valine at codon 816 of the KIT protein. KIT protein with D816V mutation acts as constitutively active tyrosine kinase that promotes cell proliferation and inhibits apoptosis. The purpose of our study was to determine the incidence of D816V mutation in the C-KIT gene in Slovenian patients with AML and in patients with suspected systemic mastocytosis. Patients and methods: In the retrospective study, 71 patients with AML and 25 patients with suspected systemic mastocytosis were included. D816V mutation in the C-KIT gene was determined by polymerase chain reaction (PCR and the resulting PCR products were analyzed by agarose gel electrophoresis. Results: D816V mutation in KIT protein was determined in 7 % of patients with AML and in 32 % patients with suspected systemic mastocytosis. Conclusions: Identification of D816V mutation in the C-KIT gene must always be performed in patients with suspected systemic mastocytosis. The determination of this mutation contributes to the diagnosis and treatment selection. The finding of D816V mutation in the C-KIT gene in patients with AML and concomitant genetic modifications RUNX-RUNX1T1 (typical translocation t(8; 21 (q22, q22 or CBFB-MYH11, which is the result of inversion on chromosome 16–(inv (16 (p13, q22, however, indicates a faster, more aggressive course of the disease and predicts a worse outcome. The finding of the mutation in other patients with AML may indicate the presence of concomitant AML and SM, which was not found in our patients.

  11. The transcriptome of the human mast cell leukemia cells HMC-1.2: an approach to identify specific changes in the gene expression profile in KitD816V systemic mastocytosis.

    Science.gov (United States)

    Haenisch, B; Herms, S; Molderings, G J

    2013-05-01

    To circumvent the costly isolation procedure associated with tissue mast cells, human mast cell lines such as HMC-1 are employed in mastocytosis research, but their relation to mutated mast cells in systemic mastocytosis has not been investigated systematically. In the present study, we determined the transcriptome of HMC-1.2 cells and compared the expression data with those reported in the literature for normal human resting lung and tonsillar mast cells as well as leukocytes from peripheral blood and mononuclear cells from bone marrow aspirates of patients with D816 V-positive systemic mastocytosis. Our results suggest that HMC-1.2 cells are an appropriate model for the investigation of this variant of systemic mast cell activation disease. The data confirm previous suggestions that the pathologically increased activity of mast cells in patients with D816 V-positive systemic mastocytosis can be deduced from the detection of mutation-related changes in the gene expression profile in leukocytes from peripheral blood and in mononuclear cells from bone marrow aspirates. Thus, mutation-related changes of the expression profile can serve as surrogates (besides clustering of mast cells, expression of CD25, and increased release of tryptase) for the presence of the mutation D816 V in tyrosine kinase Kit in patients with systemic mastocytosis according to the WHO criteria. Whether this also holds true for systemic mast cell activation disease caused by other mutations in Kit or other mast cell activity-related genes is a subject for future studies.

  12. Mastocitose sistêmica na infância: relato de 3 casos Systemic mastocytosis in childhood: report of 3 cases

    Directory of Open Access Journals (Sweden)

    Evódie I. Fernandes

    2002-04-01

    Full Text Available Objetivo: mastocitose é o termo usado para um grupo de moléstias caracterizadas pelo acúmulo de mastócitos na pele, com ou sem comprometimento de outros órgãos. Os sintomas podem ser apenas cutâneos, associados aos decorrentes dos órgãos envolvidos ou também sistêmicos, pela liberação de mediadores químicos. São descritos três casos de mastocitose sistêmica, cada um com diferentes manifestações próprias da doença.Descrição: no primeiro caso é relatado um paciente com urticária pigmentosa que evoluiu com persistência das lesões até a puberdade, quando iniciaram as manifestações sistêmicas com o comprometimento linforreticular, esplenomegalia e infiltração da medula óssea. No segundo caso, a paciente apresentava mastocitose bolhosa acompanhada de sintomas gastrintestinais, cuja investigação mostrou infiltração de mastócitos na parede intestinal. A terceira paciente ilustra a manifestação cutânea precoce e extensa da mastocitose, com uma evolução dramática para choque e posterior óbito. Comentários: são discutidos aspectos clínicos, laboratoriais, tratamento e diagnóstico.Objective: mastocytosis comprises a group of diseases characterized by accumulation of mast cells on the skin, with the possibility of affecting other systems. Symptoms can be exclusively cutaneous, associated with symptoms of the organs involved or even systemic, due to the release of chemical mediators. Three cases of systemic mastocytosis are described, each case presenting different manifestations of the disorder. Description: the first report is about a patient with urticaria pigmentosa that presented persistent lesions until puberty when systemic manifestations initiated with lymphoreticular involvement, splenomegaly and bone marrow infiltration. In the second case, the child had bullous mastocytosis associated with gastrointestinal symptoms, whose investigation showed mast cell infiltration in the intestinal wall. The third

  13. Systemic mastocytosis uncommon in KIT D816V mutation positive core-binding factor acute myeloid leukemia

    DEFF Research Database (Denmark)

    Kristensen, Thomas; Preiss, Birgitte; Broesby-Olsen, Sigurd

    2012-01-01

    Abstract The KIT D816V mutation is detected in the vast majority of adult cases of systemic mastocytosis (SM). The mutation is also frequently detected in core-binding factor acute myeloid leukemia (CBF-AML) defined by the presence of t(8;21)(q22;q22); RUNX1-RUNX1T1 or inv(16)(p13.1;q22)/t(16;16)(p...

  14. Omalizumab prevents anaphylaxis and improves symptoms in systemic mastocytosis

    DEFF Research Database (Denmark)

    Broesby-Olsen, S; Vestergaard, H; Mortz, C G

    2018-01-01

    BACKGROUND: Patients with systemic mastocytosis (SM) may suffer from mast cell (MC) mediator-related symptoms insufficiently controlled by conventional therapy. Omalizumab is an established treatment in other MC-driven diseases, but experiences in SM are limited. OBJECTIVE: To assess the efficacy...... and safety of omalizumab in SM. METHODS: In our patient cohort, we evaluated all SM patients treated with omalizumab. A physician global assessment of type and severity of symptoms was performed at baseline, at 3 and 6 months and at latest follow-up. Quality of life was assessed by visual analogue scale. S......-tryptase and KIT D816V allele burden were monitored. RESULTS: A total of 14 adult SM patients (10 ISM, 2 BMM, 1 SSM, and 1 ASM-AHN) received omalizumab with a median duration of 17 months (range: 1-73 months). One patient was excluded due to concomitant cytoreductive therapy. In the remaining 13 patients, we...

  15. Multiple vertebral fractures in young man as first manifestation of systemic mastocytosis.

    Science.gov (United States)

    Carrasco Cubero, Carmen; Chamizo Carmona, Eugenio

    Systemic mastocytosis (SM) is a clonal disease of mast cell progenitors from the bone marrow. The clinical picture varies from asymptomatic forms (indolent) to a highly aggressive form with a very short (mast cell leukemia) survival. Between 28-34% of patients with SM are related to bone condition at the time of diagnosis and 16% have symptomatic fractures. The presentation of SM as clinical vertebral fractures in young men is rare. Here, we describe a case of established osteoporosis as the only manifestation of SM. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  16. Comparison of skeletal scintigraphy and radiology for showing the osseous manifestations of generalised mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Bieler, E.U.; Wohlenberg, H.; Utech, C.

    1985-05-01

    Bone scans and skeletal X-rays of eight patients with systemic mastocytosis were reviewed. Mast cell infiltration of bone marrow had been proven histologically in every patient. Bone scan and roentgenographic findings are not specific for the disease and do not correlate well in some patients. A generalized increase of uptake was noted in two patients, a generalized decrease of skeletal activity with poor delineation of bony structures was observed in others. A circumscribed increase of activity was observed in some patients, only one patient had a normal bone scan. Roentgenographic examination revealed diffuse sclerosis of trabecular bone in three patients, osteoporosis with collaps of multiple vertebral bodies in three patients, and no abnormalities in two patients.

  17. Improved detection of the KIT D816V mutation in patients with systemic mastocytosis using a quantitative and highly sensitive real-time qPCR assay

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Møller, Michael Boe

    2011-01-01

    The vast majority of patients with systemic mastocytosis (SM) carry the somatic D816V mutation in the KIT gene. The KIT D816V mutation is one of the minor criteria for a diagnosis of SM according to the 2008 World Health Organization classification of myeloproliferative neoplasms. In the present ...

  18. MR-based trabecular bone microstructure is not altered in subjects with indolent systemic mastocytosis.

    Science.gov (United States)

    Baum, Thomas; Karampinos, Dimitrios C; Brockow, Knut; Seifert-Klauss, Vanadin; Jungmann, Pia M; Biedermann, Tilo; Rummeny, Ernst J; Bauer, Jan S; Müller, Dirk

    2015-01-01

    Subjects with indolent systemic mastocytosis (ISM) have an increased risk for osteoporosis. It has been demonstrated that trabecular bone microstructure analysis improves the prediction of bone strength beyond dual-energy X-ray absorptiometry-based bone mineral density. The purpose of this study was to obtain Magnetic Resonance (MR)-based trabecular bone microstructure parameters as advanced imaging biomarkers in subjects with ISM (n=18) and compare them with those of normal controls (n=18). Trabecular bone microstructure parameters were not significantly (P>.05) different between subjects with ISM and controls. These findings revealed important pathophysiological information about ISM-associated osteoporosis and may limit the use of trabecular bone microstructure analysis in this clinical setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Single nucleotide polymorphism array lesions, TET2, DNMT3A, ASXL1 and CBL mutations are present in systemic mastocytosis.

    Directory of Open Access Journals (Sweden)

    Fabiola Traina

    Full Text Available We hypothesized that analysis of single nucleotide polymorphism arrays (SNP-A and new molecular defects may provide new insight in the pathogenesis of systemic mastocytosis (SM. SNP-A karyotyping was applied to identify recurrent areas of loss of heterozygosity and bidirectional sequencing was performed to evaluate the mutational status of TET2, DNMT3A, ASXL1, EZH2, IDH1/IDH2 and the CBL gene family. Overall survival (OS was analyzed using the Kaplan-Meier method. We studied a total of 26 patients with SM. In 67% of SM patients, SNP-A karyotyping showed new chromosomal abnormalities including uniparental disomy of 4q and 2p spanning TET2/KIT and DNMT3A. Mutations in TET2, DNMT3A, ASXL1 and CBL were found in 23%, 12%, 12%, and 4% of SM patients, respectively. No mutations were observed in EZH2 and IDH1/IDH2. Significant differences in OS were observed for SM mutated patients grouped based on the presence of combined TET2/DNMT3A/ASXL1 mutations independent of KIT (P = 0.04 and sole TET2 mutations (P<0.001. In conclusion, TET2, DNMT3A and ASXL1 mutations are also present in mastocytosis and these mutations may affect prognosis, as demonstrated by worse OS in mutated patients.

  20. Regenerant arabidopsis lineages display a distinct genome-wide spectrum of mutations conferring variant phenotypes

    KAUST Repository

    Jiang, Caifu

    2011-07-28

    Multicellular organisms can be regenerated from totipotent differentiated somatic cell or nuclear founders [1-3]. Organisms regenerated from clonally related isogenic founders might a priori have been expected to be phenotypically invariant. However, clonal regenerant animals display variant phenotypes caused by defective epigenetic reprogramming of gene expression [2], and clonal regenerant plants exhibit poorly understood heritable phenotypic ("somaclonal") variation [4-7]. Here we show that somaclonal variation in regenerant Arabidopsis lineages is associated with genome-wide elevation in DNA sequence mutation rate. We also show that regenerant mutations comprise a distinctive molecular spectrum of base substitutions, insertions, and deletions that probably results from decreased DNA repair fidelity. Finally, we show that while regenerant base substitutions are a likely major genetic cause of the somaclonal variation of regenerant Arabidopsis lineages, transposon movement is unlikely to contribute substantially to that variation. We conclude that the phenotypic variation of regenerant plants, unlike that of regenerant animals, is substantially due to DNA sequence mutation. 2011 Elsevier Ltd. All rights reserved.

  1. Regenerant arabidopsis lineages display a distinct genome-wide spectrum of mutations conferring variant phenotypes

    KAUST Repository

    Jiang, Caifu; Mithani, Aziz; Gan, Xiangchao; Belfield, Eric J.; Klingler, John  P.; Zhu, Jian-Kang; Ragoussis, Jiannis; Mott, Richard; Harberd, Nicholas  P.

    2011-01-01

    Multicellular organisms can be regenerated from totipotent differentiated somatic cell or nuclear founders [1-3]. Organisms regenerated from clonally related isogenic founders might a priori have been expected to be phenotypically invariant. However, clonal regenerant animals display variant phenotypes caused by defective epigenetic reprogramming of gene expression [2], and clonal regenerant plants exhibit poorly understood heritable phenotypic ("somaclonal") variation [4-7]. Here we show that somaclonal variation in regenerant Arabidopsis lineages is associated with genome-wide elevation in DNA sequence mutation rate. We also show that regenerant mutations comprise a distinctive molecular spectrum of base substitutions, insertions, and deletions that probably results from decreased DNA repair fidelity. Finally, we show that while regenerant base substitutions are a likely major genetic cause of the somaclonal variation of regenerant Arabidopsis lineages, transposon movement is unlikely to contribute substantially to that variation. We conclude that the phenotypic variation of regenerant plants, unlike that of regenerant animals, is substantially due to DNA sequence mutation. 2011 Elsevier Ltd. All rights reserved.

  2. Curcumin Ingestion Inhibits Mastocytosis and Suppresses Intestinal Anaphylaxis in a Murine Model of Food Allergy.

    Directory of Open Access Journals (Sweden)

    Shannon R M Kinney

    Full Text Available IgE antibodies and mast cells play critical roles in the establishment of allergic responses to food antigens. Curcumin, the active ingredient of the curry spice turmeric, has anti-inflammatory properties, and thus may have the capacity to regulate Th2 cells and mucosal mast cell function during allergic responses. We assessed whether curcumin ingestion during oral allergen exposure can modulate the development of food allergy using a murine model of ovalbumin (OVA-induced intestinal anaphylaxis. Herein, we demonstrate that frequent ingestion of curcumin during oral OVA exposure inhibits the development of mastocytosis and intestinal anaphylaxis in OVA-challenged allergic mice. Intragastric (i.g. exposure to OVA in sensitized BALB/c mice induced a robust IgE-mediated response accompanied by enhanced OVA-IgE levels, intestinal mastocytosis, elevated serum mMCP-1, and acute diarrhea. In contrast, mice exposed to oral curcumin throughout the experimental regimen appeared to be normal and did not exhibit intense allergic diarrhea or a significant enhancement of OVA-IgE and intestinal mast cell expansion and activation. Furthermore, allergic diarrhea, mast cell activation and expansion, and Th2 responses were also suppressed in mice exposed to curcumin during the OVA-challenge phase alone, despite the presence of elevated levels of OVA-IgE, suggesting that curcumin may have a direct suppressive effect on intestinal mast cell activation and reverse food allergy symptoms in allergen-sensitized individuals. This was confirmed by observations that curcumin attenuated the expansion of both adoptively transferred bone marrow-derived mast cells (BMMCs, and inhibited their survival and activation during cell culture. Finally, the suppression of intestinal anaphylaxis by curcumin was directly linked with the inhibition of NF-κB activation in curcumin-treated allergic mice, and curcumin inhibited the phosphorylation of the p65 subunit of NF-κB in BMMCs. In

  3. Advances in the understanding and clinical management of mastocytosis and clonal mast cell activation syndromes [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    David González-de-Olano

    2016-11-01

    Full Text Available Clonal mast cell activation syndromes and indolent systemic mastocytosis without skin involvement are two emerging entities that sometimes might be clinically difficult to distinguish, and they involve a great challenge for the physician from both a diagnostic and a therapeutic point of view. Furthermore, final diagnosis of both entities requires a bone marrow study; it is recommended that this be done in reference centers. In this article, we address the current consensus and guidelines for the suspicion, diagnosis, classification, treatment, and management of these two entities.

  4. Tumour cells expressing single VEGF isoforms display distinct growth, survival and migration characteristics.

    Directory of Open Access Journals (Sweden)

    Chryso Kanthou

    Full Text Available Vascular endothelial growth factor-A (VEGF is produced by most cancer cells as multiple isoforms, which display distinct biological activities. VEGF plays an undisputed role in tumour growth, vascularisation and metastasis; nevertheless the functions of individual isoforms in these processes remain poorly understood. We investigated the effects of three main murine isoforms (VEGF188, 164 and 120 on tumour cell behaviour, using a panel of fibrosarcoma cells we developed that express them individually under endogenous promoter control. Fibrosarcomas expressing only VEGF188 (fs188 or wild type controls (fswt were typically mesenchymal, formed ruffles and displayed strong matrix-binding activity. VEGF164- and VEGF120-producing cells (fs164 and fs120 respectively were less typically mesenchymal, lacked ruffles but formed abundant cell-cell contacts. On 3D collagen, fs188 cells remained mesenchymal while fs164 and fs120 cells adopted rounded/amoeboid and a mix of rounded and elongated morphologies respectively. Consistent with their mesenchymal characteristics, fs188 cells migrated significantly faster than fs164 or fs120 cells on 2D surfaces while contractility inhibitors accelerated fs164 and fs120 cell migration. VEGF164/VEGF120 expression correlated with faster proliferation rates and lower levels of spontaneous apoptosis than VEGF188 expression. Nevertheless, VEGF188 was associated with constitutively active/phosphorylated AKT, ERK1/2 and Stat3 proteins. Differences in proliferation rates and apoptosis could be explained by defective signalling downstream of pAKT to FOXO and GSK3 in fs188 and fswt cells, which also correlated with p27/p21 cyclin-dependent kinase inhibitor over-expression. All cells expressed tyrosine kinase VEGF receptors, but these were not active/activatable suggesting that inherent differences between the cell lines are governed by endogenous VEGF isoform expression through complex interactions that are independent of tyrosine

  5. Endemic versus epidemic viral spreads display distinct patterns of HTLV-2b replication

    International Nuclear Information System (INIS)

    Gabet, Anne-Sophie; Moules, Vincent; Sibon, David; Nass, Catharie C.; Mortreux, Franck; Mauclere, Philippe; Gessain, Antoine; Murphy, Edward L.; Wattel, Eric

    2006-01-01

    As the replication pattern of leukemogenic PTLVs possesses a strong pathogenic impact, we investigated HTLV-2 replication in vivo in asymptomatic carriers belonging into 2 distinct populations infected by the same HTLV-2b subtype. They include epidemically infected American blood donors, in whom HTLV-2b has been present for only 30 years, and endemically infected Bakola Pygmies from Cameroon, characterized by a long viral endemicity (at least few generations). In blood donors, both the circulating proviral loads and the degree of infected cell proliferation were largely lower than those characterizing asymptomatic carriers infected with leukemogenic PTLVs (HTLV-1, STLV-1). This might contribute to explain the lack of known link between HTLV-2b infection and the development of malignancies in this population. In contrast, endemically infected individuals displayed high proviral loads resulting from the extensive proliferation of infected cells. The route and/or the duration of infection, viral genetic drift, host immune response, genetic background, co-infections or a combination thereof might have contributed to these differences between endemically and epidemically infected subjects. As the clonality pattern observed in endemically infected individuals is very reminiscent of that of leukemogenic PTLVs at the pre-leukemic stage, our results highlight the possible oncogenic effect of HTLV-2b infection in such population

  6. [Systemic mastocytosis: a review of the literature and of the cases in Reggio Emilia from 1986 to 1994].

    Science.gov (United States)

    D'Incà, M; Ghirarduzzi, A; Albertini, G; Iori, I

    1996-01-01

    Systemic mastocytosis is a rare pathology that can affect most systems of the human organism. Although diagnosis is often fortuitous and prognosis good in a very high percentage of cases, it can sometimes present in extremely severe and occasionally fatal forms. With the aid of the available literature, we discuss the most recent classifications, clinical features and diagnostic and therapeutic approaches to this disease. We then do an epidemiological review of the cases reported in Reggio Emilia over the past 9 years. Due to the lack of symptoms of this pathology, its reported incidence of about 0.3 new cases per 100,000 inhabitants per year is obviously underestimated. Drug therapy is purely symptomatic and does not affect its clinical evolution.

  7. Mast cell distribution in normal adult skin.

    Science.gov (United States)

    Janssens, A S; Heide, R; den Hollander, J C; Mulder, P G M; Tank, B; Oranje, A P

    2005-03-01

    To investigate mast cell distribution in normal adult skin to provide a reference range for comparison with mastocytosis. Mast cells (MCs) were counted in uninvolved skin adjacent to basal cell carcinomas and other dermatological disorders in adults. There was an uneven distribution of MCs in different body sites using the anti-tryptase monoclonal antibody technique. Numbers of MCs on the trunk, upper arm, and upper leg were similar, but were significantly different from those found on the lower leg and forearm. Two distinct groups were formed--proximal and distal. There were 77.0 MCs/mm2 at proximal body sites and 108.2 MCs/mm2 at distal sites. Adjusted for the adjacent diagnosis and age, this difference was consistent. The numbers of MCs in uninvolved skin adjacent to basal cell carcinomas and other dermatological disorders were not different from those in the control group. Differences in the numbers of MCs between the distal and the proximal body sites must be considered when MCs are counted for a reliable diagnosis of mastocytosis. A pilot study in patients with mastocytosis underlined the variation in the numbers of MCs in mastocytosis and normal skin, but showed a considerable overlap. The observed numbers of MCs in adults cannot be extrapolated to children. MC numbers varied significantly between proximal and distal body sites and these differences must be considered when MCs are counted for a reliable diagnosis of mastocytosis. There was a considerable overlap between the numbers of MCs in mastocytosis and normal skin.

  8. Conceptual Design of Industrial Process Displays

    DEFF Research Database (Denmark)

    Pedersen, C.R.; Lind, Morten

    1999-01-01

    discusses aspects of process display design taking into account both the designer's and the operator's points of view. Three aspects are emphasized: the operator tasks, the display content and the display form. The distinction between these three aspects is the basis for proposing an outline for a display......Today, process displays used in industry are often designed on the basis of piping and instrumentation diagrams without any method of ensuring that the needs of the operators are fulfilled. Therefore, a method for a systematic approach to the design of process displays is needed. This paper...... by a simple example from a plant with batch processes. Later the method is applied to develop a supervisory display for a condenser system in a nuclear power plant. The differences between the continuous plant domain of power production and the batch processes from the example are analysed and broad...

  9. Improvements in data display

    International Nuclear Information System (INIS)

    Ellis, G.W.

    1979-01-01

    An analog signal processor is described in this patent for connecting a source of analog signals to a cathode ray tube display in order to extend the dynamic range of the display. This has important applications in the field of computerised X-ray tomography since significant medical information, such as tumours in soft tissue, is often represented by minimal level changes in image density. Cathode ray tube displays are limited to approximately 15 intensity levels. Thus if both strong and weak absorption of the X-rays occurs, the dynamic range of the transmitted signals will be too large to permit small variations to be examined directly on a cathode ray display. Present tomographic image reconstruction methods are capable of quantising X-ray absorption density measurements into 256 or more distinct levels and a description is given of the electronics which enables the upper and lower range of intensity levels to be independently set and continuously varied. (UK)

  10. 33 CFR 173.27 - Numbers: Display; size; color.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Numbers: Display; size; color...: Display; size; color. (a) Each number required by § 173.15 must: (1) Be painted on or permanently attached...; (3) Contrast with the color of the background and be distinctly visible and legible; (4) Have spaces...

  11. The pursuit of optimal distinctiveness and consumer preferences.

    Science.gov (United States)

    He, Lingnan; Cong, Feng; Liu, Yanping; Zhou, Xinyue

    2010-10-01

    This article investigates the effect of optimal distinctiveness on consumer product consumption. The authors argue that consumers acquire and display material possessions to restore their optimal levels of distinctiveness. Results showed that placing consumers in a state of low distinctiveness increased desire to acquire distinctive products, whereas perceptions of high distinctiveness reduced desire to acquire such products. Consumers' desire for distinctiveness-related products held true for various consumer choices, including willingness to pay more for limited-edition products and preference for unpopular gifts. This finding has implications for understanding consumer choice in expressing identity. © 2010 The Authors. Scandinavian Journal of Psychology © 2010 The Scandinavian Psychological Associations.

  12. What is shared, what is different? Core relational themes and expressive displays of eight positive emotions.

    Science.gov (United States)

    Campos, Belinda; Shiota, Michelle N; Keltner, Dacher; Gonzaga, Gian C; Goetz, Jennifer L

    2013-01-01

    Understanding positive emotions' shared and differentiating features can yield valuable insight into the structure of positive emotion space and identify emotion states, or aspects of emotion states, that are most relevant for particular psychological processes and outcomes. We report two studies that examined core relational themes (Study 1) and expressive displays (Study 2) for eight positive emotion constructs--amusement, awe, contentment, gratitude, interest, joy, love, and pride. Across studies, all eight emotions shared one quality: high positive valence. Distinctive core relational theme and expressive display patterns were found for four emotions--amusement, awe, interest, and pride. Gratitude was associated with a distinct core relational theme but not an expressive display. Joy and love were each associated with a distinct expressive display but their core relational themes also characterised pride and gratitude, respectively. Contentment was associated with a distinct expressive display but not a core relational theme. The implications of this work for the study of positive emotion are discussed.

  13. FLOCK cluster analysis of mast cell event clustering by high-sensitivity flow cytometry predicts systemic mastocytosis.

    Science.gov (United States)

    Dorfman, David M; LaPlante, Charlotte D; Pozdnyakova, Olga; Li, Betty

    2015-11-01

    In our high-sensitivity flow cytometric approach for systemic mastocytosis (SM), we identified mast cell event clustering as a new diagnostic criterion for the disease. To objectively characterize mast cell gated event distributions, we performed cluster analysis using FLOCK, a computational approach to identify cell subsets in multidimensional flow cytometry data in an unbiased, automated fashion. FLOCK identified discrete mast cell populations in most cases of SM (56/75 [75%]) but only a minority of non-SM cases (17/124 [14%]). FLOCK-identified mast cell populations accounted for 2.46% of total cells on average in SM cases and 0.09% of total cells on average in non-SM cases (P < .0001) and were predictive of SM, with a sensitivity of 75%, a specificity of 86%, a positive predictive value of 76%, and a negative predictive value of 85%. FLOCK analysis provides useful diagnostic information for evaluating patients with suspected SM, and may be useful for the analysis of other hematopoietic neoplasms. Copyright© by the American Society for Clinical Pathology.

  14. Two distinct groups within the Bacillus subtilis group display significantly different spore heat resistance properties.

    Science.gov (United States)

    Berendsen, Erwin M; Zwietering, Marcel H; Kuipers, Oscar P; Wells-Bennik, Marjon H J

    2015-02-01

    The survival of bacterial spores after heat treatment and the subsequent germination and outgrowth in a food product can lead to spoilage of the food product and economical losses. Prediction of time-temperature conditions that lead to sufficient inactivation requires access to detailed spore thermal inactivation kinetics of relevant model strains. In this study, the thermal inactivation kinetics of spores of fourteen strains belonging to the Bacillus subtilis group were determined in detail, using both batch heating in capillary tubes and continuous flow heating in a micro heater. The inactivation data were fitted using a log linear model. Based on the spore heat resistance data, two distinct groups (p subtilis group could be identified. One group of strains had spores with an average D120 °C of 0.33 s, while the spores of the other group displayed significantly higher heat resistances, with an average D120 °C of 45.7 s. When comparing spore inactivation data obtained using batch- and continuous flow heating, the z-values were significantly different, hence extrapolation from one system to the other was not justified. This study clearly shows that heat resistances of spores from different strains in the B. subtilis group can vary greatly. Strains can be separated into two groups, to which different spore heat inactivation kinetics apply. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. New displays and new emotions: a commentary on Rozin and Cohen (2003).

    Science.gov (United States)

    Keltner, Dacher; Shiota, Michelle N

    2003-03-01

    In this article, the authors elaborate on 3 ideas advanced in P. Rozin and A. B. Cohen's (2003) innovative study of facial expression. Taking a cue from their discovery of new expressive behaviors (e.g., the narrowed eyebrows), the authors review recent studies showing that emotions are conveyed in more channels than usually studied, including posture, gaze patterns, voice, and touch. Building on their claim that confusion has a distinct display, the authors review evidence showing distinct displays for 3 self-conscious emotions (embarrassment, shame, and pride), 5 positive emotions (amusement, desire, happiness, love, interest), and sympathy and compassion. Finally, the authors offer a functional definition of emotion to integrate these findings on "new" displays and emotions.

  16. Eukaryotic ribosome display with in situ DNA recovery.

    Science.gov (United States)

    He, Mingyue; Edwards, Bryan M; Kastelic, Damjana; Taussig, Michael J

    2012-01-01

    Ribosome display is a cell-free display technology for in vitro selection and optimisation of proteins from large diversified libraries. It operates through the formation of stable protein-ribosome-mRNA (PRM) complexes and selection of ligand-binding proteins, followed by DNA recovery from the selected genetic information. Both prokaryotic and eukaryotic ribosome display systems have been developed. In this chapter, we describe the eukaryotic rabbit reticulocyte method in which a distinct in situ single-primer RT-PCR procedure is used to recover DNA from the selected PRM complexes without the need for prior disruption of the ribosome.

  17. Morphologically occult systemic mastocytosis in bone marrow: clinicopathologic features and an algorithmic approach to diagnosis.

    Science.gov (United States)

    Reichard, Kaaren K; Chen, Dong; Pardanani, Animesh; McClure, Rebecca F; Howard, Matthew T; Kurtin, Paul J; Wood, Adam J; Ketterling, Rhett P; King, Rebecca L; He, Rong; Morice, William G; Hanson, Curtis A

    2015-09-01

    Bone marrow (BM) biopsy specimens involved by systemic mastocytosis (SM) typically show multifocal, compact, dense aggregates of spindled mast cells (MCs). However, some cases lack aggregate formation and fulfill the World Health Organization 2008 criteria for SM, based on minor criteria. We identified 26 BM cases of KIT D816V-mutated, morphologically occult SM in the BM. All patients had some combination of allergic/MC activating symptoms. Peripheral blood counts were generally normal. BM aspirates showed 5% or less MCs, which were only occasionally spindled. BM biopsy specimens showed no morphologic classic MC lesions. Tryptase immunohistochemistry (IHC) demonstrated interstitial, individually distributed MCs (up to 5%) with prominent spindling, lacking aggregate formation. MCs coexpressed CD25 by IHC and/or flow cytometry. Spindled MCs constituted more than 25% of total MCs in all cases and more than 50% in 20 of 26 cases. Morphologically occult involvement of normal-appearing BM by SM will be missed without appropriate clinical suspicion and pathologic evaluation by tryptase and CD25 IHC and KIT D816V mutation analysis. On the basis of these findings, we propose a cost-effective, data-driven, evidence-based algorithmic approach to the workup of these cases. Copyright© by the American Society for Clinical Pathology.

  18. SETD2 and histone H3 lysine 36 methylation deficiency in advanced systemic mastocytosis.

    Science.gov (United States)

    Martinelli, G; Mancini, M; De Benedittis, C; Rondoni, M; Papayannidis, C; Manfrini, M; Meggendorfer, M; Calogero, R; Guadagnuolo, V; Fontana, M C; Bavaro, L; Padella, A; Zago, E; Pagano, L; Zanotti, R; Scaffidi, L; Specchia, G; Albano, F; Merante, S; Elena, C; Savini, P; Gangemi, D; Tosi, P; Ciceri, F; Poletti, G; Riccioni, L; Morigi, F; Delledonne, M; Haferlach, T; Cavo, M; Valent, P; Soverini, S

    2018-01-01

    The molecular basis of advanced systemic mastocytosis (SM) is not fully understood and despite novel therapies the prognosis remains dismal. Exome sequencing of an index-patient with mast cell leukemia (MCL) uncovered biallelic loss-of-function mutations in the SETD2 histone methyltransferase gene. Copy-neutral loss-of-heterozygosity at 3p21.3 (where SETD2 maps) was subsequently found in SM patients and prompted us to undertake an in-depth analysis of SETD2 copy number, mutation status, transcript expression and methylation levels, as well as functional studies in the HMC-1 cell line and in a validation cohort of 57 additional cases with SM, including MCL, aggressive SM and indolent SM. Reduced or no SETD2 protein expression-and consequently, H3K36 trimethylation-was found in all cases and inversely correlated with disease aggressiveness. Proteasome inhibition rescued SETD2 expression and H3K36 trimethylation and resulted in marked accumulation of ubiquitinated SETD2 in SETD2-deficient patients but not in patients with near-normal SETD2 expression. Bortezomib and, to a lesser extent, AZD1775 alone or in combination with midostaurin induced apoptosis and reduced clonogenic growth of HMC-1 cells and of neoplastic mast cells from advanced SM patients. Our findings may have implications for prognostication of SM patients and for the development of improved treatment approaches in advanced SM.

  19. Development of an Evaluation Method for the Design Complexity of Computer-Based Displays

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Ju; Lee, Seung Woo; Kang, Hyun Gook; Seong, Poong Hyun [KAIST, Daejeon (Korea, Republic of); Park, Jin Kyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    The importance of the design of human machine interfaces (HMIs) for human performance and the safety of process industries has long been continuously recognized for many decades. Especially, in the case of nuclear power plants (NPPs), HMIs have significant implications for the safety of the NPPs because poor HMIs can impair the decision making ability of human operators. In order to support and increase the decision making ability of human operators, advanced HMIs based on the up-to-date computer technology are provided. Human operators in advanced main control room (MCR) acquire information through video display units (VDUs) and large display panel (LDP), which is required for the operation of NPPs. These computer-based displays contain a huge amount of information and present it with a variety of formats compared to those of a conventional MCR. For example, these displays contain more display elements such as abbreviations, labels, icons, symbols, coding, etc. As computer-based displays contain more information, the complexity of advanced displays becomes greater due to less distinctiveness of each display element. A greater understanding is emerging about the effectiveness of designs of computer-based displays, including how distinctively display elements should be designed. This study covers the early phase in the development of an evaluation method for the design complexity of computer-based displays. To this end, a series of existing studies were reviewed to suggest an appropriate concept that is serviceable to unravel this problem

  20. Serum tryptase monitoring in indolent systemic mastocytosis: association with disease features and patient outcome.

    Directory of Open Access Journals (Sweden)

    Almudena Matito

    Full Text Available BACKGROUND: Serum baseline tryptase (sBT is a minor diagnostic criterion for systemic mastocytosis (SM of undetermined prognostic impact. We monitored sBT levels in indolent SM (ISM patients and investigated its utility for predicting disease behaviour and outcome. METHODS: In total 74 adult ISM patients who were followed for ≥48 months and received no cytoreductive therapy were retrospectively studied. Patients were classified according to the pattern of evolution of sBT observed. RESULTS: Overall 16/74 (22% cases had decreasing sBT levels, 48 (65% patients showed increasing sBT levels and 10 (13% patients showed a fluctuating pattern. Patients with significantly increasing sBT (sBT slope ≥0.15 after 48 months of follow-up showed a slightly greater rate of development of diffuse bone sclerosis (13% vs. 2% and hepatomegaly plus splenomegaly (16% vs. 5%, as well as a significantly greater frequency of multilineage vs. mast cells (MC-restricted KIT mutation (p = 0.01 together with a greater frequency of cases with progression of ISM to smouldering and aggressive SM (p = 0.03, and a shorter progression-free survival (p = 0.03. CONCLUSIONS: Monitoring of sBT in ISM patients is closely associated with poor prognosis disease features as well as with disease progression, pointing out the need for a closer follow-up in ISM patients with progressively increasing sBT values.

  1. Application of the Decomposition Method to the Design Complexity of Computer-based Display

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Ju; Lee, Seung Woo; Seong, Poong Hyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Jin Kyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The importance of the design of human machine interfaces (HMIs) for human performance and safety has long been recognized in process industries. In case of nuclear power plants (NPPs), HMIs have significant implications for the safety of the NPPs since poor implementation of HMIs can impair the operators' information searching ability which is considered as one of the important aspects of human behavior. To support and increase the efficiency of the operators' information searching behavior, advanced HMIs based on computer technology are provided. Operators in advanced main control room (MCR) acquire information through video display units (VDUs), and large display panel (LDP) required for the operation of NPPs. These computer-based displays contain a very large quantity of information and present them in a variety of formats than conventional MCR. For example, these displays contain more elements such as abbreviations, labels, icons, symbols, coding, and highlighting than conventional ones. As computer-based displays contain more information, complexity of the elements becomes greater due to less distinctiveness of each element. A greater understanding is emerging about the effectiveness of designs of computer-based displays, including how distinctively display elements should be designed. And according to Gestalt theory, people tend to group similar elements based on attributes such as shape, color or pattern based on the principle of similarity. Therefore, it is necessary to consider not only human operator's perception but the number of element consisting of computer-based display

  2. Application of the Decomposition Method to the Design Complexity of Computer-based Display

    International Nuclear Information System (INIS)

    Kim, Hyoung Ju; Lee, Seung Woo; Seong, Poong Hyun; Park, Jin Kyun

    2012-01-01

    The importance of the design of human machine interfaces (HMIs) for human performance and safety has long been recognized in process industries. In case of nuclear power plants (NPPs), HMIs have significant implications for the safety of the NPPs since poor implementation of HMIs can impair the operators' information searching ability which is considered as one of the important aspects of human behavior. To support and increase the efficiency of the operators' information searching behavior, advanced HMIs based on computer technology are provided. Operators in advanced main control room (MCR) acquire information through video display units (VDUs), and large display panel (LDP) required for the operation of NPPs. These computer-based displays contain a very large quantity of information and present them in a variety of formats than conventional MCR. For example, these displays contain more elements such as abbreviations, labels, icons, symbols, coding, and highlighting than conventional ones. As computer-based displays contain more information, complexity of the elements becomes greater due to less distinctiveness of each element. A greater understanding is emerging about the effectiveness of designs of computer-based displays, including how distinctively display elements should be designed. And according to Gestalt theory, people tend to group similar elements based on attributes such as shape, color or pattern based on the principle of similarity. Therefore, it is necessary to consider not only human operator's perception but the number of element consisting of computer-based display

  3. Prospective evaluation of the diagnostic value of sensitive KIT D816V mutation analysis of blood in adults with suspected systemic mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, H; Bindslev-Jensen, C

    2017-01-01

    BACKGROUND: Sensitive KIT D816V mutation analysis of blood has been proposed to guide bone marrow (BM) investigation in suspected systemic mastocytosis (SM). The aim of this prospective study was for the first time to compare the D816V status of the "screening blood sample" used to guide BM biopsy...... in suspected SM to the outcome of the subsequent BM investigation. METHODS: Fifty-eight adult patients with suspected SM were included. The outcome of sensitive KIT D816V analysis of blood was compared to the result of the BM investigation. RESULTS: Screening blood samples from 44 of 58 patients tested D816V...... patients did not fulfill any diagnostic SM criteria (excluding tryptase criterion). Of the 48 SM patients, 90% tested D816V-positive. Thirteen SM patients presented with Hymenoptera venom-induced anaphylaxis, no skin lesions, and baseline serum tryptase ≤20 ng/mL. Of these, 92% tested D816V...

  4. Low-cost general purpose spectral display unit using an IBM PC

    International Nuclear Information System (INIS)

    Robinson, S.L.

    1985-10-01

    Many physics experiments require acquisition and analysis of spectral data. commercial minicomputer-based multichannel analyzers collect detected counts at various energies, create a histogram of the counts in memory, and display the resultant spectra. They acquire data and provide the user-to-display interface. The system discussed separates functions into the three modular components of data acquisition, storage, and display. This decoupling of functions allows the experimenter to use any number of detectors for data collection before forwarding up to 64 spectra to the display unit, thereby increasing data throughput over that available with commercial systems. An IBM PC was chosen for the low-cost, general purpose display unit. Up to four spectra may be displayed simultaneously in different colors. The histogram saves 1024 channels per detector, 640 of which may be distinctly displayed per spectra. The IEEE-488 standard provides the data path between the IBM PC and the data collection unit. Data is sent to the PC under interrupt control, using direct memory access. Display manipulations available via keyboard are also discussed

  5. Market trends in the projection display industry

    Science.gov (United States)

    Dash, Sweta

    2000-04-01

    The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection television segment. But rear LCD (liquid crystal display) and rear reflective (DLP, or Digital Light ProcessingTM) televisions are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are still popular in the high-end home theater market. Front LCD technology and front DLP technology dominate the business market. Traditional light valve technology was the only solution for applications requiring high light outputs, but new three-chip DLP projectors meet the higher light output requirements at a lower price. In the last few years the strongest growth has been in the business market for multimedia presentation applications. This growth was due to the continued increase in display pixel formats, the continued reduction in projector weight, and the improved price/performance ratio. The projection display market will grow at a significant rate during the next five years, driven by the growth in ultraportable (market to digital and HDTV products.

  6. Game engines and immersive displays

    Science.gov (United States)

    Chang, Benjamin; Destefano, Marc

    2014-02-01

    While virtual reality and digital games share many core technologies, the programming environments, toolkits, and workflows for developing games and VR environments are often distinct. VR toolkits designed for applications in visualization and simulation often have a different feature set or design philosophy than game engines, while popular game engines often lack support for VR hardware. Extending a game engine to support systems such as the CAVE gives developers a unified development environment and the ability to easily port projects, but involves challenges beyond just adding stereo 3D visuals. In this paper we outline the issues involved in adapting a game engine for use with an immersive display system including stereoscopy, tracking, and clustering, and present example implementation details using Unity3D. We discuss application development and workflow approaches including camera management, rendering synchronization, GUI design, and issues specific to Unity3D, and present examples of projects created for a multi-wall, clustered, stereoscopic display.

  7. A low-cost general purpose spectral display unit using an IBM PC

    International Nuclear Information System (INIS)

    Robinson, S.L.

    1986-01-01

    Many physics experiments require acquisition and analysis of spectral data. Commercial minicomputer-based multichannel analyzers collect detected counts at various energies, create a histogram of the counts in memory, and display the resultant spectra. They acquire data and provide the user-to-display interface. The system discussed separates functions into the three modular components of data acquisition, storage, and display. This decoupling of functions allows the experimenter to use any number of detectors for data collection before forwarding up to 64 spectra to the display unit, thereby increasing data throughput over that available with commercial systems. An IBM PC was chosen for the low-cost, general purpose display unit. Up to four spectra may be displayed simultaneously in different colors. The histogram saves 1024 channels per detector, 640 of which may be distinctly displayed per spectra. The IEEE-488 standard provides the data path between the IBM PC and the data collection unit. Data is sent to the PC under interrupt control, using direct memory access. Display manipulations available via keyboard are also discussed

  8. Embarrassment: its distinct form and appeasement functions.

    Science.gov (United States)

    Keltner, D; Buswell, B N

    1997-11-01

    The authors address 2 questions about embarrassment. First, Is embarrassment a distinct emotion? The evidence indicates that the antecedents, experience, and display of embarrassment, and to a limited extent its autonomic physiology, are distinct from shame, guilt, and amusement and share the dynamic, temporal characteristics of emotion. Second, What are the theoretical accounts of embarrassment? Three accounts focus on the causes of embarrassment, positioning that it follows the loss of self-esteem, concern for others' evaluations, or absence of scripts to guide interactions. A fourth account focuses on the effects of the remedial actions of embarrassment, which correct preceding transgressions. A fifth account focuses on the functional parallels between embarrassment and nonhuman appeasement. The discussion focuses on unanswered questions about embarrassment.

  9. Distinct kinetics of serine and threonine dephosphorylation are essential for mitosis

    DEFF Research Database (Denmark)

    Hein, Jamin B; Hertz, Emil P T; Garvanska, Dimitriya H

    2017-01-01

    Protein phosphatase 2A (PP2A) in complex with B55 regulatory subunits reverses cyclin-dependent kinase 1 (Cdk1) phosphorylations at mitotic exit. Interestingly, threonine and serine residues phosphorylated by Cdk1 display distinct phosphorylation dynamics, but the biological significance remains ...

  10. 3D display system using monocular multiview displays

    Science.gov (United States)

    Sakamoto, Kunio; Saruta, Kazuki; Takeda, Kazutoki

    2002-05-01

    A 3D head mounted display (HMD) system is useful for constructing a virtual space. The authors have researched the virtual-reality systems connected with computer networks for real-time remote control and developed a low-priced real-time 3D display for building these systems. We developed a 3D HMD system using monocular multi-view displays. The 3D displaying technique of this monocular multi-view display is based on the concept of the super multi-view proposed by Kajiki at TAO (Telecommunications Advancement Organization of Japan) in 1996. Our 3D HMD has two monocular multi-view displays (used as a visual display unit) in order to display a picture to the left eye and the right eye. The left and right images are a pair of stereoscopic images for the left and right eyes, then stereoscopic 3D images are observed.

  11. Circular displays: control/display arrangements and stereotype strength with eight different display locations.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Two experiments are reported that were designed to investigate control/display arrangements having high stereotype strengths when using circular displays. Eight display locations relative to the operator and control were tested with rotational and translational controls situated on different planes according to the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (2010). (Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT), Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, 54: 1022-1026). In many cases, there was little effect of display locations, indicating the importance of the Worringham and Beringer (1998. Directional stimulus-response compatibility: a test of three alternative principles. Ergonomics, 41(6), 864-880) Visual Field principle and an extension of this principle for rotary controls (Hoffmann and Chan (2013). The Worringham and Beringer 'visual field' principle for rotary controls. Ergonomics, 56(10), 1620-1624). The initial indicator position (12, 3, 6 and 9 o'clock) had a major effect on control/display stereotype strength for many of the six controls tested. Best display/control arrangements are listed for each of the different control types (rotational and translational) and for the planes on which they are mounted. Data have application where a circular display is used due to limited display panel space and applies to space-craft, robotics operators, hospital equipment and home appliances. Practitioner Summary: Circular displays are often used when there is limited space available on a control panel. Display/control arrangements having high stereotype strength are listed for four initial indicator positions. These arrangements are best for design purposes.

  12. High color fidelity thin film multilayer systems for head-up display use

    Science.gov (United States)

    Tsou, Yi-Jen D.; Ho, Fang C.

    1996-09-01

    Head-up display is gaining increasing access in automotive vehicles for indication and position/navigation purposes. An optical combiner, which allows the driver to receive image information from outside and inside of the automobile, is the essential part of this display device. Two multilayer thin film combiner coating systems with distinctive polarization selectivity and broad band spectral neutrality are discussed. One of the coating systems was designed to be located at the lower portion of the windshield. The coating reduced the exterior glare by approximately 45% and provided about 70% average see-through transmittance in addition to the interior information display. The other coating system was designed to be integrated with the sunshield located at the upper portion of the windshield. The coating reflected the interior information display while reducing direct sunlight penetration to 25%. Color fidelity for both interior and exterior images were maintained in both systems. This facilitated the display of full-color maps. Both coating systems were absorptionless and environmentally durable. Designs, fabrication, and performance of these coating systems are addressed.

  13. The effect of display movement angle, indicator type and display location on control/display stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S

    2017-08-01

    Much research on stereotype strength relating display and control movements for displays moving in the vertical or horizontal directions has been reported. Here we report effects of display movement angle, where the display moves at angles (relative to the vertical) of between 0° and 180°. The experiment used six different controls, four display locations relative to the operator and three types of indicator. Indicator types were included because of the strong effects of the 'scale-side principle' that are variable with display angle. A directional indicator had higher stereotype strength than a neutral indicator, and showed an apparent reversal in control/display stereotype direction beyond an angle of 90°. However, with a neutral indicator this control reversal was not present. Practitioner Summary: The effects of display moving at angles other than the four cardinal directions, types of control, location of display and types of indicator are investigated. Indicator types (directional and neutral) have an effect on stereotype strength and may cause an apparent control reversal with change of display movement angle.

  14. Visual search asymmetries within color-coded and intensity-coded displays.

    Science.gov (United States)

    Yamani, Yusuke; McCarley, Jason S

    2010-06-01

    Color and intensity coding provide perceptual cues to segregate categories of objects within a visual display, allowing operators to search more efficiently for needed information. Even within a perceptually distinct subset of display elements, however, it may often be useful to prioritize items representing urgent or task-critical information. The design of symbology to produce search asymmetries (Treisman & Souther, 1985) offers a potential technique for doing this, but it is not obvious from existing models of search that an asymmetry observed in the absence of extraneous visual stimuli will persist within a complex color- or intensity-coded display. To address this issue, in the current study we measured the strength of a visual search asymmetry within displays containing color- or intensity-coded extraneous items. The asymmetry persisted strongly in the presence of extraneous items that were drawn in a different color (Experiment 1) or a lower contrast (Experiment 2) than the search-relevant items, with the targets favored by the search asymmetry producing highly efficient search. The asymmetry was attenuated but not eliminated when extraneous items were drawn in a higher contrast than search-relevant items (Experiment 3). Results imply that the coding of symbology to exploit visual search asymmetries can facilitate visual search for high-priority items even within color- or intensity-coded displays. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  15. MR1-restricted MAIT cells display ligand discrimination and pathogen selectivity through distinct T cell receptor usage

    DEFF Research Database (Denmark)

    Gold, Marielle C.; McLaren, James E.; Reistetter, Joseph A.

    2015-01-01

    with this interpretation, MAIT cell clones with distinct TCRs responded differentially to a riboflavin metabolite. These results suggest that MAIT cells can discriminate between pathogen-derived ligands in a clonotype-dependent manner, providing a basis for adaptive memory via recruitment of specific repertoires shaped...

  16. Individual microRNAs (miRNAs) display distinct mRNA targeting "rules".

    Science.gov (United States)

    Wang, Wang-Xia; Wilfred, Bernard R; Xie, Kevin; Jennings, Mary H; Hu, Yanling Hu; Stromberg, Arnold J; Nelson, Peter T

    2010-01-01

    MicroRNAs (miRNAs) guide Argonaute (AGO)-containing microribonucleoprotein (miRNP) complexes to target mRNAs.It has been assumed that miRNAs behave similarly to each other with regard to mRNA target recognition. The usual assumptions, which are based on prior studies, are that miRNAs target preferentially sequences in the 3'UTR of mRNAs,guided by the 5' "seed" portion of the miRNAs. Here we isolated AGO- and miRNA-containing miRNPs from human H4 tumor cells by co-immunoprecipitation (co-IP) with anti-AGO antibody. Cells were transfected with miR-107, miR-124,miR-128, miR-320, or a negative control miRNA. Co-IPed RNAs were subjected to downstream high-density Affymetrix Human Gene 1.0 ST microarray analyses using an assay we validated previously-a "RIP-Chip" experimental design. RIP-Chip data provided a list of mRNAs recruited into the AGO-miRNP in correlation to each miRNA. These experimentally identified miRNA targets were analyzed for complementary six nucleotide "seed" sequences within the transfected miRNAs. We found that miR-124 targets tended to have sequences in the 3'UTR that would be recognized by the 5' seed of miR-124, as described in previous studies. By contrast, miR-107 targets tended to have 'seed' sequences in the mRNA open reading frame, but not the 3' UTR. Further, mRNA targets of miR-128 and miR-320 are less enriched for 6-mer seed sequences in comparison to miR-107 and miR-124. In sum, our data support the importance of the 5' seed in determining binding characteristics for some miRNAs; however, the "binding rules" are complex, and individual miRNAs can have distinct sequence determinants that lead to mRNA targeting.

  17. Biophysical subsets of embryonic stem cells display distinct phenotypic and morphological signatures.

    Directory of Open Access Journals (Sweden)

    Tom Bongiorno

    Full Text Available The highly proliferative and pluripotent characteristics of embryonic stem cells engender great promise for tissue engineering and regenerative medicine, but the rapid identification and isolation of target cell phenotypes remains challenging. Therefore, the objectives of this study were to characterize cell mechanics as a function of differentiation and to employ differences in cell stiffness to select population subsets with distinct mechanical, morphological, and biological properties. Biomechanical analysis with atomic force microscopy revealed that embryonic stem cells stiffened within one day of differentiation induced by leukemia inhibitory factor removal, with a lagging but pronounced change from spherical to spindle-shaped cell morphology. A microfluidic device was then employed to sort a differentially labeled mixture of pluripotent and differentiating cells based on stiffness, resulting in pluripotent cell enrichment in the soft device outlet. Furthermore, sorting an unlabeled population of partially differentiated cells produced a subset of "soft" cells that was enriched for the pluripotent phenotype, as assessed by post-sort characterization of cell mechanics, morphology, and gene expression. The results of this study indicate that intrinsic cell mechanical properties might serve as a basis for efficient, high-throughput, and label-free isolation of pluripotent stem cells, which will facilitate a greater biological understanding of pluripotency and advance the potential of pluripotent stem cell differentiated progeny as cell sources for tissue engineering and regenerative medicine.

  18. Differential autoshaping to common and distinctive elements of positive and negative discriminative stimuli.

    Science.gov (United States)

    Wasserman, E A; Anderson, P A

    1974-11-01

    The learning by hungry pigeons of a discrimination between two successively presented compound visual stimuli was investigated using a two-key autoshaping procedure. Common and distinctive stimulus elements were simultaneously presented on separate keys and either followed by food delivery, S+, or not, S-. The subjects acquired both between-trial and within-trial discriminations. On S+ trials, pigeons pecked the distinctive stimulus more than the common stimulus; before responding ceased on S- trials, they pecked the common stimulus more than the distinctive one. Mastery of the within-display discrimination during S+ trials preceded mastery of the between-trials discrimination. These findings extend the Jenkins-Sainsbury analysis of discriminations based upon a single distinguishing feature to discriminations in which common and distinctive elements are associated with both the positive and negative discriminative stimuli. The similarity of these findings to other effects found in autoshaping-approach to signals that forecast reinforcement and withdrawal from signals that forecast nonreinforcement-is also discussed.

  19. European display scene

    Science.gov (United States)

    Bartlett, Christopher T.

    2000-08-01

    The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.

  20. Effect of display location on control-display stereotype strength for translational and rotational controls with linear displays.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.

  1. Yeast surface display platform for rapid discovery of conformationally selective nanobodies

    DEFF Research Database (Denmark)

    McMahon, Conor; Baier, Alexander S.; Pascolutti, Roberta

    2018-01-01

    this problem, we report a fully in vitro platform for nanobody discovery based on yeast surface display. We provide a blueprint for identifying nanobodies, demonstrate the utility of the library by crystallizing a nanobody with its antigen, and most importantly, we utilize the platform to discover...... conformationally selective nanobodies to two distinct human GPCRs. To facilitate broad deployment of this platform, the library and associated protocols are freely available for nonprofit research....

  2. Displays in scintigraphy

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.E.; Pizer, S.M.

    1977-01-01

    Displays have several functions: to transmit images, to permit interaction, to quantitate features and to provide records. The main characteristics of displays used for image transmission are their resolution, dynamic range, signal-to-noise ratio and uniformity. Considerations of visual acuity suggest that the display element size should be much less than the data element size, and in current practice at least 256X256 for a gamma camera image. The dynamic range for image transmission should be such that at least 64 levels of grey (or equivalent) are displayed. Scanner displays are also considered, and in particular, the requirements of a whole-body camera are examined. A number of display systems and devices are presented including a 'new' heated object colour display system. Interaction with displays is considered, including background subtraction, contrast enhancement, position indication and region-of-interest generation. Such systems lead to methods of quantitation, which imply knowledge of the expected distributions. Methods for intercomparing displays are considered. Polaroid displays, which have for so long dominated the field, are in the process of being replaced by stored image displays, now that large cheap memories exist which give an equivalent image quality. The impact of this in nuclear medicine is yet to be seen, but a major effect will be to enable true quantitation. (author)

  3. Motivation to hide emotion and children's understanding of the distinction between real and apparent emotions.

    Science.gov (United States)

    Gosselin, Pierre; Warren, Madeleine; Diotte, Michèle

    2002-12-01

    The authors investigated the extent to which children's understanding of the distinction between real and apparent emotions varied according to the motivation to hide emotions. Children, aged 6-7 and 10-11 years, were read stories designed to elicit either prosocial or self-protective motivated display rules and were asked to predict the facial expressions the protagonists would make to hide felt emotions. Children were found to understand the distinction between real and apparent emotions very well, independently of the type of motivation. Contrary to predictions, boys understood this distinction better than did girls when the motivation to hide positive emotions was prosocial. Children perceived neutralization as the most appropriate strategy to hide felt emotions, followed by masking.

  4. EAP application to artificial tactile feel display of virtual reality

    Science.gov (United States)

    Konyo, Masashi; Tadokoro, Satoshi; Takamori, Toshi; Oguro, Keisuke

    2001-07-01

    A tactile feel display device for virtual reality was developed using Nafion-Platinum composite type EAP actuator (known as IPMC or ICPF). Conventional tactile displays can hardly express tactile human feeling of the fine touch of the surface of a cloth, because their mechanisms cannot excite minute distributed stimuli on human skin. We propose a new ciliary device using ICPF actuators. The ICPF has sufficient softness, utilizing the passive material property, that complex control is not required. The low drive voltage is safe enough for the touch of fingers. Its simple operation mechanism allows miniaturization for practical equipments. The developed device was designed with a number of cilia consisting of ICPF actuators, where a cilium is 2 mm wide and 5 mm long. An ICPF membrane is cut into pectination, and only the cilium part is plated and has a function of an actuator. An inclined configuration of the cilia produces variety of stimuli to human skin controlling frequencies. We tried to display both pressure and vibration at the same time using modulated low and high frequencies. The result clearly shows that over 80% of the subjects sensed some special tactile feeling. A comparison with real material samples shows that this display can present a subtle distinction of tactile feeling of cloth, especially like a towel and denim.

  5. Monocular display unit for 3D display with correct depth perception

    Science.gov (United States)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  6. A Distinct Population of Microglia Supports Adult Neurogenesis in the Subventricular Zone

    DEFF Research Database (Denmark)

    Ribeiro Xavier, Anna L.; Kress, Benjamin T.; Goldman, Steven A.

    2015-01-01

    found that microglia residing in the SVZ and adjacent rostral migratory stream (RMS) comprise a morphologically and antigenically distinct phenotype of immune effectors. Whereas exhibiting characteristics of alternatively activated microglia, the SVZ/RMS microglia were clearly distinguished by their low...... STATEMENT: Microglial cells are a specialized population of macrophages in the CNS, playing key roles as immune mediators. As integral components in the CNS, the microglia stand out for using the same mechanisms, phagocytosis and cytochemokine release, to promote homeostasis, synaptic pruning, and neural...... toward olfactory bulb layers. In addition to other unique populations residing in the SVZ niche, microglia display distinct morphofunctional properties that boost neuronal progenitor survival and migration in the mammalian brain....

  7. GDNF family ligands display distinct action profiles on cultured GABAergic and serotonergic neurons of rat ventral mesencephalon

    DEFF Research Database (Denmark)

    Ducray, Angélique; Krebs, Sandra H:; Schaller, Benoft

    2006-01-01

    Glial-cell-line-derived neurotrophic factor (GDNF), neurturin (NRTN), artemin (ARTN) and persephin (PSPN), known as the GDNF family ligands (GFLs), influence the development, survival and differentiation of cultured dopaminergic neurons from ventral mesencephalon (VM). Detailed knowledge about...... factors for VM GABAergic and serotonergic neurons, demonstrating characteristic individual action profiles emphasizing their important and distinct roles during brain development....

  8. Hepatocellular carcinoma displays distinct DNA methylation signatures with potential as clinical predictors.

    Directory of Open Access Journals (Sweden)

    Hector Hernandez-Vargas

    Full Text Available BACKGROUND: Hepatocellular carcinoma (HCC is characterized by late detection and fast progression, and it is believed that epigenetic disruption may be the cause of its molecular and clinicopathological heterogeneity. A better understanding of the global deregulation of methylation states and how they correlate with disease progression will aid in the design of strategies for earlier detection and better therapeutic decisions. METHODS AND FINDINGS: We characterized the changes in promoter methylation in a series of 30 HCC tumors and their respective surrounding tissue and identified methylation signatures associated with major risk factors and clinical correlates. A wide panel of cancer-related gene promoters was analyzed using Illumina bead array technology, and CpG sites were then selected according to their ability to classify clinicopathological parameters. An independent series of HCC tumors and matched surrounding tissue was used for validation of the signatures. We were able to develop and validate a signature of methylation in HCC. This signature distinguished HCC from surrounding tissue and from other tumor types, and was independent of risk factors. However, aberrant methylation of an independent subset of promoters was associated with tumor progression and etiological risk factors (HBV or HCV infection and alcohol consumption. Interestingly, distinct methylation of an independent panel of gene promoters was strongly correlated with survival after cancer therapy. CONCLUSION: Our study shows that HCC tumors exhibit specific DNA methylation signatures associated with major risk factors and tumor progression stage, with potential clinical applications in diagnosis and prognosis.

  9. The IFN Response in Bats Displays Distinctive IFN-Stimulated Gene Expression Kinetics with Atypical RNASEL Induction.

    Science.gov (United States)

    De La Cruz-Rivera, Pamela C; Kanchwala, Mohammed; Liang, Hanquan; Kumar, Ashwani; Wang, Lin-Fa; Xing, Chao; Schoggins, John W

    2018-01-01

    Bats host a large number of zoonotic viruses, including several viruses that are highly pathogenic to other mammals. The mechanisms underlying this rich viral diversity are unknown, but they may be linked to unique immunological features that allow bats to act as asymptomatic viral reservoirs. Vertebrates respond to viral infection by inducing IFNs, which trigger antiviral defenses through IFN-stimulated gene (ISG) expression. Although the IFN system of several bats is characterized at the genomic level, less is known about bat IFN-mediated transcriptional responses. In this article, we show that IFN signaling in bat cells from the black flying fox ( Pteropus alecto ) consists of conserved and unique ISG expression profiles. In IFN-stimulated cells, bat ISGs comprise two unique temporal subclusters with similar early induction kinetics but distinct late-phase declines. In contrast, human ISGs lack this decline phase and remained elevated for longer periods. Notably, in unstimulated cells, bat ISGs were expressed more highly than their human counterparts. We also found that the antiviral effector 2-5A-dependent endoribonuclease, which is not an ISG in humans, is highly IFN inducible in black flying fox cells and contributes to cell-intrinsic control of viral infection. These studies reveal distinctive innate immune features that may underlie a unique virus-host relationship in bats. Copyright © 2017 by The American Association of Immunologists, Inc.

  10. Towards an optimal model for a bistable nematic liquid crystal display device

    KAUST Repository

    Cummings, L. J.

    2013-03-13

    Bistable liquid crystal displays offer the potential for considerable power savings compared with conventional (monostable) LCDs. The existence of two stable field-free states that are optically distinct means that contrast can be maintained in a display without an externally applied electric field. An applied field is required only to switch the device from one state to the other, as needed. In this paper we examine a theoretical model of a possible bistable device, originally proposed by Cummings and Richardson (Euro J Appl Math 17:435-463 2006), and explore means by which it may be optimized, in terms of optical contrast, manufacturing considerations, switching field strength, and switching times. The compromises inherent in these conflicting design criteria are discussed. © 2013 Springer Science+Business Media Dordrecht.

  11. Common and distinct genetic properties of ESCRT-II components in Drosophila.

    Directory of Open Access Journals (Sweden)

    Hans-Martin Herz

    Full Text Available BACKGROUND: Genetic studies in yeast have identified class E vps genes that form the ESCRT complexes required for protein sorting at the early endosome. In Drosophila, mutations of the ESCRT-II component vps25 cause endosomal defects leading to accumulation of Notch protein and increased Notch pathway activity. These endosomal and signaling defects are thought to account for several phenotypes. Depending on the developmental context, two different types of overgrowth can be detected. Tissue predominantly mutant for vps25 displays neoplastic tumor characteristics. In contrast, vps25 mutant clones in a wild-type background trigger hyperplastic overgrowth in a non-autonomous manner. In addition, vps25 mutant clones also promote apoptotic resistance in a non-autonomous manner. PRINCIPAL FINDINGS: Here, we genetically characterize the remaining ESCRT-II components vps22 and vps36. Like vps25, mutants of vps22 and vps36 display endosomal defects, accumulate Notch protein and--when the tissue is predominantly mutant--show neoplastic tumor characteristics. However, despite these common phenotypes, they have distinct non-autonomous phenotypes. While vps22 mutations cause strong non-autonomous overgrowth, they do not affect apoptotic resistance. In contrast, vps36 mutations increase apoptotic resistance, but have little effect on non-autonomous proliferation. Further characterization reveals that although all ESCRT-II mutants accumulate Notch protein, only vps22 and vps25 mutations trigger Notch activity. CONCLUSIONS/SIGNIFICANCE: The ESCRT-II components vps22, vps25 and vps36 display common and distinct genetic properties. Our data redefine the role of Notch for hyperplastic and neoplastic overgrowth in these mutants. While Notch is required for hyperplastic growth, it appears to be dispensable for neoplastic transformation.

  12. The Plasmodium serine-type SERA proteases display distinct expression patterns and non-essential in vivo roles during life cycle progression of the malaria parasite.

    Science.gov (United States)

    Putrianti, Elyzana D; Schmidt-Christensen, Anja; Arnold, Iris; Heussler, Volker T; Matuschewski, Kai; Silvie, Olivier

    2010-06-01

    Parasite proteases play key roles in several fundamental steps of the Plasmodium life cycle, including haemoglobin degradation, host cell invasion and parasite egress. Plasmodium exit from infected host cells appears to be mediated by a class of papain-like cysteine proteases called 'serine repeat antigens' (SERAs). A SERA subfamily, represented by Plasmodium falciparum SERA5, contains an atypical active site serine residue instead of a catalytic cysteine. Members of this SERAser subfamily are abundantly expressed in asexual blood stages, rendering them attractive drug and vaccine targets. In this study, we show by antibody localization and in vivo fluorescent tagging with the red fluorescent protein mCherry that the two P. berghei serine-type family members, PbSERA1 and PbSERA2, display differential expression towards the final stages of merozoite formation. Via targeted gene replacement, we generated single and double gene knockouts of the P. berghei SERAser genes. These loss-of-function lines progressed normally through the parasite life cycle, suggesting a specialized, non-vital role for serine-type SERAs in vivo. Parasites lacking PbSERAser showed increased expression of the cysteine-type PbSERA3. Compensatory mechanisms between distinct SERA subfamilies may thus explain the absence of phenotypical defect in SERAser disruptants, and challenge the suitability to develop potent antimalarial drugs based on specific inhibitors of Plasmodium serine-type SERAs.

  13. Pediatric Expression of Mast Cell Activation Disorders

    DEFF Research Database (Denmark)

    Broesby-Olsen, Sigurd; Carter, Melody; Kjaer, Henrik Fomsgaard

    2018-01-01

    , anaphylaxis, mastocytosis, and other conditions where MC activation is contributing to the pathogenesis. This article focuses on clinical presentations, challenges, and controversies in pediatric mastocytosis and gives an overview of current knowledge and areas in need of further research....

  14. Differential autoshaping to common and distinctive elements of positive and negative discriminative stimuli1

    Science.gov (United States)

    Wasserman, Edward A.; Anderson, Patricia A.

    1974-01-01

    The learning by hungry pigeons of a discrimination between two successively presented compound visual stimuli was investigated using a two-key autoshaping procedure. Common and distinctive stimulus elements were simultaneously presented on separate keys and either followed by food delivery, S+, or not, S−. The subjects acquired both between-trial and within-trial discriminations. On S+ trials, pigeons pecked the distinctive stimulus more than the common stimulus; before responding ceased on S− trials, they pecked the common stimulus more than the distinctive one. Mastery of the within-display discrimination during S+ trials preceded mastery of the between-trials discrimination. These findings extend the Jenkins-Sainsbury analysis of discriminations based upon a single distinguishing feature to discriminations in which common and distinctive elements are associated with both the positive and negative discriminative stimuli. The similarity of these findings to other effects found in autoshaping—approach to signals that forecast reinforcement and withdrawal from signals that forecast nonreinforcement—is also discussed. PMID:16811812

  15. Distinction of Fly Artifacts from Human Blood using Immunodetection.

    Science.gov (United States)

    Rivers, David B; Acca, Gillian; Fink, Marc; Brogan, Rebecca; Chen, Dorothy; Schoeffield, Andrew

    2018-02-21

    Insect stains produced by necrophagous flies are indistinguishable morphologically from human bloodstains. At present, no diagnostic tests exist to overcome this deficiency. As the first step toward developing a chemical test to recognize fly artifacts, polyclonal antisera were generated in rats against three distinct antigenic sequences of fly cathepsin D-like proteinase, an enzyme that is structurally distinct in cyclorrhaphous Diptera from other animals. The resulting rat antisera bound to artifacts produced by Protophormia terraenovae and synthetic peptides used to generate the polyclonal antisera, but not with any type of mammalian blood tested in immunoassays. Among the three antisera, anti-md3 serum displayed the highest reactivity for fly stains, demonstrated cross-reactivity for all synthetic peptides representing antigenic sequences of the mature fly enzyme, and bound artifacts originating from the fly digestive tract. Further work is needed to determine whether the antisera are suitable for non-laboratory conditions. © 2018 American Academy of Forensic Sciences.

  16. Invisible Display in Aluminum

    DEFF Research Database (Denmark)

    Prichystal, Jan Phuklin; Hansen, Hans Nørgaard; Bladt, Henrik Henriksen

    2005-01-01

    Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish for an integ......Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish...... for an integrated display in a metal surface is often ruled by design and functionality of a product. The integration of displays in metal surfaces requires metal removal in order to clear the area of the display to some extent. The idea behind an invisible display in Aluminum concerns the processing of a metal...

  17. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    International Nuclear Information System (INIS)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    2005-01-01

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L amb ) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m 2 , LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to

  18. Agent-specific learning signals for self-other distinction during mentalising.

    Directory of Open Access Journals (Sweden)

    Sam Ereira

    2018-04-01

    Full Text Available Humans have a remarkable ability to simulate the minds of others. How the brain distinguishes between mental states attributed to self and mental states attributed to someone else is unknown. Here, we investigated how fundamental neural learning signals are selectively attributed to different agents. Specifically, we asked whether learning signals are encoded in agent-specific neural patterns or whether a self-other distinction depends on encoding agent identity separately from this learning signal. To examine this, we tasked subjects to learn continuously 2 models of the same environment, such that one was selectively attributed to self and the other was selectively attributed to another agent. Combining computational modelling with magnetoencephalography (MEG enabled us to track neural representations of prediction errors (PEs and beliefs attributed to self, and of simulated PEs and beliefs attributed to another agent. We found that the representational pattern of a PE reliably predicts the identity of the agent to whom the signal is attributed, consistent with a neural self-other distinction implemented via agent-specific learning signals. Strikingly, subjects exhibiting a weaker neural self-other distinction also had a reduced behavioural capacity for self-other distinction and displayed more marked subclinical psychopathological traits. The neural self-other distinction was also modulated by social context, evidenced in a significantly reduced decoding of agent identity in a nonsocial control task. Thus, we show that self-other distinction is realised through an encoding of agent identity intrinsic to fundamental learning signals. The observation that the fidelity of this encoding predicts psychopathological traits is of interest as a potential neurocomputational psychiatric biomarker.

  19. Advanced Colorimetry of Display Systems: Tetra-Chroma3 Display Unit

    Directory of Open Access Journals (Sweden)

    J. Kaiser

    2005-06-01

    Full Text Available High-fidelity color image reproduction is one of the key issues invisual telecommunication systems, for electronic commerce,telemedicine, digital museum and so on. All colorimetric standards ofdisplay systems are up to the present day trichromatic. But, from theshape of a horseshoe-area of all existing colors in the CIE xychromaticity diagram it follows that with three real reproductivelights, the stated area in the CIE xy chromaticity diagram cannot beoverlaid. The expansion of the color gamut of a display device ispossible in a few ways. In this paper, the way of increasing the numberof primaries is studied. The fourth cyan primary is added to threeconventional ones to enlarge the color gamut of reproduction towardscyans and yellow-oranges. The original method of color management forthis new display unit is introduced. In addition, the color gamut ofthe designed additive-based display is successfully compared with thecolor gamut of a modern subtractive-based system. A display with morethan three primary colors is called a multiprimary color display. Thevery advantageous property of such display is the possibility todisplay metameric colors.

  20. Distinct collective states due to trade-off between attractive and repulsive couplings

    Science.gov (United States)

    Sathiyadevi, K.; Chandrasekar, V. K.; Senthilkumar, D. V.; Lakshmanan, M.

    2018-03-01

    We investigate the effect of repulsive coupling together with an attractive coupling in a network of nonlocally coupled oscillators. To understand the complex interaction between these two couplings we introduce a control parameter in the repulsive coupling which plays a crucial role in inducing distinct complex collective patterns. In particular, we show the emergence of various cluster chimera death states through a dynamically distinct transition route, namely the oscillatory cluster state and coherent oscillation death state as a function of the repulsive coupling in the presence of the attractive coupling. In the oscillatory cluster state, the oscillators in the network are grouped into two distinct dynamical states of homogeneous and inhomogeneous oscillatory states. Further, the network of coupled oscillators follow the same transition route in the entire coupling range. Depending upon distinct coupling ranges, the system displays different number of clusters in the death state and oscillatory state. We also observe that the number of coherent domains in the oscillatory cluster state exponentially decreases with increase in coupling range and obeys a power-law decay. Additionally, we show analytical stability for observed solitary state, synchronized state, and incoherent oscillation death state.

  1. Choosing colors for map display icons using models of visual search.

    Science.gov (United States)

    Shive, Joshua; Francis, Gregory

    2013-04-01

    We show how to choose colors for icons on maps to minimize search time using predictions of a model of visual search. The model analyzes digital images of a search target (an icon on a map) and a search display (the map containing the icon) and predicts search time as a function of target-distractor color distinctiveness and target eccentricity. We parameterized the model using data from a visual search task and performed a series of optimization tasks to test the model's ability to choose colors for icons to minimize search time across icons. Map display designs made by this procedure were tested experimentally. In a follow-up experiment, we examined the model's flexibility to assign colors in novel search situations. The model fits human performance, performs well on the optimization tasks, and can choose colors for icons on maps with novel stimuli to minimize search time without requiring additional model parameter fitting. Models of visual search can suggest color choices that produce search time reductions for display icons. Designers should consider constructing visual search models as a low-cost method of evaluating color assignments.

  2. An Adult Developmental Approach to Perceived Facial Attractiveness and Distinctiveness

    Directory of Open Access Journals (Sweden)

    Natalie C. Ebner

    2018-05-01

    Full Text Available Attractiveness and distinctiveness constitute facial features with high biological and social relevance. Bringing a developmental perspective to research on social-cognitive face perception, we used a large set of faces taken from the FACES Lifespan Database to examine effects of face and perceiver characteristics on subjective evaluations of attractiveness and distinctiveness in young (20–31 years, middle-aged (44–55 years, and older (70–81 years men and women. We report novel findings supporting variations by face and perceiver age, in interaction with gender and emotion: although older and middle-aged compared to young perceivers generally rated faces of all ages as more attractive, young perceivers gave relatively higher attractiveness ratings to young compared to middle-aged and older faces. Controlling for variations in attractiveness, older compared to young faces were viewed as more distinctive by young and middle-aged perceivers. Age affected attractiveness more negatively for female than male faces. Furthermore, happy faces were rated as most attractive, while disgusted faces were rated as least attractive, particularly so by middle-aged and older perceivers and for young and female faces. Perceivers largely agreed on distinctiveness ratings for neutral and happy emotions, but older and middle-aged compared to young perceivers rated faces displaying negative emotions as more distinctive. These findings underscore the importance of a lifespan perspective on perception of facial characteristics and suggest possible effects of age on goal-directed perception, social motivation, and in-group bias. This publication makes available picture-specific normative data for experimental stimulus selection.

  3. Distinctive identity claims in federal systems: Judicial policing of subnational variance

    DEFF Research Database (Denmark)

    Abat Ninet, Antoni; Gardner, James A.

    2016-01-01

    nationally imposed limits on their power typically have at their disposal many tools with which to press against formal boundaries. Federal systems, moreover, frequently display a surprising degree of tolerance for subnational obstruction, disobedience, and other behaviors intended to expand subnational...... authority and influence, even over national objection. This tolerance, however, has limits. In this article, we examine a set of rulings by national constitutional courts invalidating formalized claims by subnational units to a distinctive subnational identity. The emphatically negative reactions...

  4. Microlaser-based displays

    Science.gov (United States)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  5. Handbook of display technology

    CERN Document Server

    Castellano, Joseph A

    1992-01-01

    This book presents a comprehensive review of technical and commercial aspects of display technology. It provides design engineers with the information needed to select proper technology for new products. The book focuses on flat, thin displays such as light-emitting diodes, plasma display panels, and liquid crystal displays, but it also includes material on cathode ray tubes. Displays include a large number of products from televisions, auto dashboards, radios, and household appliances, to gasoline pumps, heart monitors, microwave ovens, and more.For more information on display tech

  6. Liquid crystal display

    International Nuclear Information System (INIS)

    Takami, K.

    1981-01-01

    An improved liquid crystal display device is described which can display letters, numerals and other necessary patterns in the night time using a minimized amount of radioactive material. To achieve this a self-luminous light source is placed in a limited region corresponding to a specific display area. (U.K.)

  7. INFORMATION DISPLAY: CONSIDERATIONS FOR DESIGNING COMPUTER-BASED DISPLAY SYSTEMS

    International Nuclear Information System (INIS)

    O'HARA, J.M.; PIRUS, D.; BELTRATCCHI, L.

    2004-01-01

    This paper discussed the presentation of information in computer-based control rooms. Issues associated with the typical displays currently in use are discussed. It is concluded that these displays should be augmented with new displays designed to better meet the information needs of plant personnel and to minimize the need for interface management tasks (the activities personnel have to do to access and organize the information they need). Several approaches to information design are discussed, specifically addressing: (1) monitoring, detection, and situation assessment; (2) routine task performance; and (3) teamwork, crew coordination, collaborative work

  8. Group A rotavirus and norovirus display sharply distinct seasonal profiles in Belém, northern Brazil

    Directory of Open Access Journals (Sweden)

    Jones Anderson Monteiro Siqueira

    2013-08-01

    Full Text Available Several viruses have been associated with acute gastroenteritis (AGE, and group A rotavirus (RVA and nor-ovirus (NoV are the most prevalent. This study aimed to assess their prevalence among children hospitalised for diarrhoea during a three-year surveillance study. From May 2008-April 2011, overall positivity rates of 21.6% (628/2904 and 35.4% (171/483 were observed for RVA and NoV, respectively. The seasonality observed indicated distinct patterns when both viruses were compared. This finding may explain why hospitalisation for AGE remains constant throughout the year. Continuous AGE monitoring is needed to better assess the patterns of infection.

  9. Molecular cloning and pharmacology of functionally distinct isoforms of the human histamine H(3) receptor

    DEFF Research Database (Denmark)

    Wellendorph, Petrine; Goodman, M W; Burstein, E S

    2002-01-01

    The pharmacology of histamine H(3) receptors suggests the presence of distinct receptor isoforms or subtypes. We herein describe multiple, functionally distinct, alternatively spliced isoforms of the human H(3) receptor. Combinatorial splicing at three different sites creates at least six distinct...... receptor isoforms, of which isoforms 1, 2, and 4, encode functional proteins. Detailed pharmacology on isoforms 1 (unspliced receptor), and 2 (which has an 80 amino acid deletion within the third intracellular loop of the protein) revealed that both isoforms displayed robust responses to a series of known...... revealed a rank order of potency at both isoforms of clobenpropit>iodophenpropit>thioperamide, and these drugs are fivefold less potent at isoform 2 than isoform 1. To further explore the pharmacology of H(3) receptor function, we screened 150 clinically relevant neuropsychiatric drugs for H(3) receptor...

  10. Liquid Crystal Airborne Display

    Science.gov (United States)

    1977-08-01

    Cum.nings, J. P., et al., Properties and Limitations oe Liquid Crystals for Aircraft Displays, Honeywell Corporate Researc ."I Center, Final Report HR-72...basic module could be used to build displays for both the commercial and military! 157- marhecs, and so would establi sh a broad and sizable market ... market for the display becomes a reality; therein lies, f TABLE 16 THE COURSE OF FUTURE DISPLAY DEVELOPMENT Today 1976-77 1980 1985 Display Size 2" 1 3.2

  11. JAVA Stereo Display Toolkit

    Science.gov (United States)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  12. Latest development of display technologies

    International Nuclear Information System (INIS)

    Gao Hong-Yue; Yao Qiu-Xiang; Liu Pan; Zheng Zhi-Qiang; Liu Ji-Cheng; Zheng Hua-Dong; Zeng Chao; Yu Ying-Jie; Sun Tao; Zeng Zhen-Xiang

    2016-01-01

    In this review we will focus on recent progress in the field of two-dimensional (2D) and three-dimensional (3D) display technologies. We present the current display materials and their applications, including organic light-emitting diodes (OLEDs), flexible OLEDs quantum dot light emitting diodes (QLEDs), active-matrix organic light emitting diodes (AMOLEDs), electronic paper (E-paper), curved displays, stereoscopic 3D displays, volumetric 3D displays, light field 3D displays, and holographic 3D displays. Conventional 2D display devices, such as liquid crystal devices (LCDs) often result in ambiguity in high-dimensional data images because of lacking true depth information. This review thus provides a detailed description of 3D display technologies. (topical review)

  13. Enhancing Electrophoretic Display Lifetime: Thiol-Polybutadiene Evaporation Barrier Property Response to Network Microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Cook, Caitlyn Christian [California State Polytechnic State Univ., San Luis Obispo, CA (United States)

    2017-02-27

    An evaporation barrier is required to enhance the lifetime of electrophoretic deposition (EPD) displays. As EPD functions on the basis of reversible deposition and resuspension of colloids suspended in a solvent, evaporation of the solvent ultimately leads to device failure. Incorporation of a thiol-polybutadiene elastomer into EPD displays enabled display lifetime surpassing six months in counting and catalyzed rigid display transition into a flexible package. Final flexible display transition to mass production compels an electronic-ink approach to encapsulate display suspension within an elastomer shell. Final thiol-polybutadiene photosensitive resin network microstructure was idealized to be dense, homogeneous, and expose an elastic response to deformation. Research at hand details an approach to understanding microstructural change within display elastomers. Polybutadiene-based resin properties are modified via polymer chain structure, with and without added aromatic urethane methacrylate difunctionality, and in measuring network response to variation in thiol and initiator concentration. Dynamic mechanical analysis results signify that cross-linked segments within a difunctionalized polybutadiene network were on average eight times more elastically active than that of linked segments within a non-functionalized polybutadiene network. Difunctionalized polybutadiene samples also showed a 2.5 times greater maximum elastic modulus than non-functionalized samples. Hybrid polymer composed of both polybutadiene chains encompassed TE-2000 stiffness and B-1000 elasticity for use in encapsulating display suspension. Later experiments measured kinetic and rheological response due to alteration in dithiol cross-linker chain length via real time Fourier transform infrared spectroscopy and real-time dynamic rheology. Distinct differences were discovered between dithiol resin systems, as maximum thiol conversion achieved in short and long chain length dithiols was 86% and

  14. Displays and simulators

    Science.gov (United States)

    Mohon, N.

    A 'simulator' is defined as a machine which imitates the behavior of a real system in a very precise manner. The major components of a simulator and their interaction are outlined in brief form, taking into account the major components of an aircraft flight simulator. Particular attention is given to the visual display portion of the simulator, the basic components of the display, their interactions, and their characteristics. Real image displays are considered along with virtual image displays, and image generators. Attention is given to an advanced simulator for pilot training, a holographic pancake window, a scan laser image generator, the construction of an infrared target simulator, and the Apollo Command Module Simulator.

  15. Displays enabling mobile multimedia

    Science.gov (United States)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  16. On Integrity of Flexible Displays

    Science.gov (United States)

    Bouten, Piet C. P.

    Nowadays two display types are dominant in the display market: the bulky cathode ray tube (CRT) and liquid crystal displays (LCD). Both types use glass as substrate material. The LCD display is the dominant player for mobile applications, in for instance mobile phones and portable computers. In the development of displays and their applications a clear interest exists to replace the rigid rectangular display cells by free-shaped, curved or even roll-up cells. These types of applications require flexible displays.

  17. Book Display as Adult Service

    Directory of Open Access Journals (Sweden)

    Matthew S. Moore

    1997-03-01

    Full Text Available 無Book display as an adult service is defined as choosing and positioning adult books from the collection to increase their circulation. The author contrasts bookstore arrangement for sales versus library arrangement for access. The paper considers the library-as-a-whole as a display, examines the right size for an in-library display, and discusses mass displays, end-caps, on-shelf displays, and the Tiffany approach. The author proposes that an effective display depends on an imaginative, unifying theme, and that book displays are part of the joy of libraries.

  18. Versatile protein recognition by the encoded display of multiple chemical elements on a constant macrocyclic scaffold

    Science.gov (United States)

    Li, Yizhou; De Luca, Roberto; Cazzamalli, Samuele; Pretto, Francesca; Bajic, Davor; Scheuermann, Jörg; Neri, Dario

    2018-03-01

    In nature, specific antibodies can be generated as a result of an adaptive selection and expansion of lymphocytes with suitable protein binding properties. We attempted to mimic antibody-antigen recognition by displaying multiple chemical diversity elements on a defined macrocyclic scaffold. Encoding of the displayed combinations was achieved using distinctive DNA tags, resulting in a library size of 35,393,112. Specific binders could be isolated against a variety of proteins, including carbonic anhydrase IX, horseradish peroxidase, tankyrase 1, human serum albumin, alpha-1 acid glycoprotein, calmodulin, prostate-specific antigen and tumour necrosis factor. Similar to antibodies, the encoded display of multiple chemical elements on a constant scaffold enabled practical applications, such as fluorescence microscopy procedures or the selective in vivo delivery of payloads to tumours. Furthermore, the versatile structure of the scaffold facilitated the generation of protein-specific chemical probes, as illustrated by photo-crosslinking.

  19. Children's Control/Display Stereotypes.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S; Tai, Judy P C

    2018-06-01

    Objective The aim of this study was to determine control/display stereotypes for children of a range of ages and development of these stereotypes with age. Background Little is known about control/display stereotypes for children of different ages and the way in which these stereotypes develop with age. This study is part of a program to determine the need to design differentially for these age groups. Method We tested four groups of children with various tasks (age groups 5 to 7, 8 to 10, 11 to 13, 14 to 16), with about 30 in each group. Examples of common tasks were opening a bottle, turning on taps, and allocating numbers to keypads. More complex tasks involved rotating a control to move a display in a requested direction. Results Tasks with which different age groups were familiar showed no effect of age group. Different control/display arrangements generally showed an increase in stereotype strength with age, with dependence on the form of the control/display arrangement. Two-dimensional arrangements, with the control on the same plane as the display, had higher stereotype strength than three-dimensional arrangements for all age groups, suggesting an effect of familiarity with controls and displays with increasing age. Conclusion Children's control/display stereotypes do not differ greatly from those of adults, and hence, design for children older than 5 years of age, for control/display stereotypes, can be the same as that for adult populations. Application When designing devices for children, the relationship between controls and displays can be as for adult populations, for which there are considerable experimental data.

  20. Augmenting digital displays with computation

    Science.gov (United States)

    Liu, Jing

    As we inevitably step deeper and deeper into a world connected via the Internet, more and more information will be exchanged digitally. Displays are the interface between digital information and each individual. Naturally, one fundamental goal of displays is to reproduce information as realistically as possible since humans still care a lot about what happens in the real world. Human eyes are the receiving end of such information exchange; therefore it is impossible to study displays without studying the human visual system. In fact, the design of displays is rather closely coupled with what human eyes are capable of perceiving. For example, we are less interested in building displays that emit light in the invisible spectrum. This dissertation explores how we can augment displays with computation, which takes both display hardware and the human visual system into consideration. Four novel projects on display technologies are included in this dissertation: First, we propose a software-based approach to driving multiview autostereoscopic displays. Our display algorithm can dynamically assign views to hardware display zones based on multiple observers' current head positions, substantially reducing crosstalk and stereo inversion. Second, we present a dense projector array that creates a seamless 3D viewing experience for multiple viewers. We smoothly interpolate the set of viewer heights and distances on a per-vertex basis across the arrays field of view, reducing image distortion, crosstalk, and artifacts from tracking errors. Third, we propose a method for high dynamic range display calibration that takes into account the variation of the chrominance error over luminance. We propose a data structure for enabling efficient representation and querying of the calibration function, which also allows user-guided balancing between memory consumption and the amount of computation. Fourth, we present user studies that demonstrate that the ˜ 60 Hz critical flicker fusion

  1. Display of adenoregulin with a novel Pichia pastoris cell surface display system.

    Science.gov (United States)

    Ren, Ren; Jiang, Zhengbing; Liu, Meiyun; Tao, Xinyi; Ma, Yushu; Wei, Dongzhi

    2007-02-01

    Two Pichia pastoris cell surface display vectors were constructed. The vectors consisted of the flocculation functional domain of Flo1p with its own secretion signal sequence or the alpha-factor secretion signal sequence, a polyhistidine (6xHis) tag for detection, an enterokinase recognition site, and the insertion sites for target proteins. Adenoregulin (ADR) is a 33-amino-acid antimicrobial peptide isolated from Phyllomedusa bicolor skin. The ADR was expressed and displayed on the Pichia pastoris KM71 cell surface with the system reported. The displayed recombinant ADR fusion protein was detected by fluorescence microscopy and confocal laser scanning microscopy (CLSM). The antimicrobial activity of the recombinant adenoregulin was detected after proteolytic cleavage of the fusion protein on cell surface. The validity of the Pichia pastoris cell surface display vectors was proved by the displayed ADR.

  2. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  3. Flat panel display - Impurity doping technology for flat panel displays

    International Nuclear Information System (INIS)

    Suzuki, Toshiharu

    2005-01-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified

  4. Handbook of Visual Display Technology

    CERN Document Server

    Cranton, Wayne; Fihn, Mark

    2012-01-01

    The Handbook of Visual Display Technology is a unique work offering a comprehensive description of the science, technology, economic and human interface factors associated with the displays industry. An invaluable compilation of information, the Handbook will serve as a single reference source with expert contributions from over 150 international display professionals and academic researchers. All classes of display device are covered including LCDs, reflective displays, flexible solutions and emissive devices such as OLEDs and plasma displays, with discussion of established principles, emergent technologies, and particular areas of application. The wide-ranging content also encompasses the fundamental science of light and vision, image manipulation, core materials and processing techniques, display driving and metrology.

  5. Polymer Dispersed Liquid Crystal Displays

    Science.gov (United States)

    Doane, J. William

    The following sections are included: * INTRODUCTION AND HISTORICAL DEVELOPMENT * PDLC MATERIALS PREPARATION * Polymerization induced phase separation (PIPS) * Thermally induced phase separation (TIPS) * Solvent induced phase separation (SIPS) * Encapsulation (NCAP) * RESPONSE VOLTAGE * Dielectric and resistive effects * Radial configuration * Bipolar configuration * Other director configurations * RESPONSE TIME * DISPLAY CONTRAST * Light scattering and index matching * Incorporation of dyes * Contrast measurements * PDLC DISPLAY DEVICES AND INNOVATIONS * Reflective direct view displays * Large-scale, flexible displays * Switchable windows * Projection displays * High definition spatial light modulator * Haze-free PDLC shutters: wide angle view displays * ENVIRONMENTAL STABILITY * ACKNOWLEDGEMENTS * REFERENCES

  6. Information rich display design

    International Nuclear Information System (INIS)

    Welch, Robin; Braseth, Alf Ove; Veland, Oeystein

    2004-01-01

    This paper presents the concept Information Rich Displays. The purpose of Information Rich Displays (IRDs) is to condensate prevailing information in process displays in such a way that each display format (picture) contains more relevant information for the user. Compared to traditional process control displays, this new concept allows the operator to attain key information at a glance and at the same time allows for improved monitoring of larger portions of the process. This again allows for reduced navigation between both process and trend displays and ease the cognitive demand on the operator. This concept has been created while working on designing display prototypes for the offshore petroleum production facilities of tomorrow. Offshore installations basically consist of wells, separation trains (where oil, gas and water are separated from each other), an oil tax measurement system (where oil quality is measured and the pressure increased to allow for export), gas compression (compression of gas for export) and utility systems (water treatment, chemical systems etc.). This means that an offshore control room operator has to deal with a complex process that comprises several functionally different systems. The need for a new approach to offshore display format design is in particular based on shortcomings in today's designs related to the keyhole effect, where the display format only reveals a fraction of the whole process. Furthermore, the upcoming introduction of larger off- and on-shore operation centres will increase the size and complexity of the operators' work domain. In the light of the increased demands on the operator, the proposed IRDs aim to counter the negative effects this may have on the workload. In this work we have attempted to classify the wide range of different roles an operator can have in different situations. The information content and amount being presented to the operator in a display should be viewed in context of the roles the

  7. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  8. Display technologies for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang

    2018-02-01

    With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.

  9. Next generation smart window display using transparent organic display and light blocking screen.

    Science.gov (United States)

    Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk

    2018-04-02

    Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.

  10. Drug hypersensitivity in clonal mast cell disorders

    DEFF Research Database (Denmark)

    Bonadonna, P; Pagani, M; Aberer, W

    2015-01-01

    and severity of immediate hypersensitivity reactions. Mastocytosis in adults is associated with a history of anaphylaxis in 22-49%. Fatal anaphylaxis has been described particularly following hymenoptera stings, but also occasionally after the intake of drugs such as nonsteroidal anti-inflammatory drugs......, opioids and drugs in the perioperative setting. However, data on the frequency of drug hypersensitivity in mastocytosis and vice versa are scarce and evidence for an association appears to be limited. Nevertheless, clonal MC disorders should be ruled out in cases of severe anaphylaxis: basal serum...... tryptase determination, physical examination for cutaneous mastocytosis lesions, and clinical characteristics of anaphylactic reaction might be useful for differential diagnosis. In this position paper, the ENDA group performed a literature search on immediate drug hypersensitivity reactions in clonal MC...

  11. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  12. Nuclear Medicine Image Display. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, H. [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-12-15

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  13. Nuclear Medicine Image Display. Chapter 14

    International Nuclear Information System (INIS)

    Bergmann, H.

    2014-01-01

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  14. Display systems for NPP control

    International Nuclear Information System (INIS)

    Rozov, S.S.

    1988-01-01

    Main trends in development of display systems used as the means for image displaying in NPP control systems are considered. It is shown that colour display devices appear to be the most universal means for concentrated data presentation. Along with digital means the display systems provide for high-speed response, sufficient for operative control of executive mechanisms. A conclusion is drawn that further development of display systems will move towards creation of large colour fields (on reflection base or with multicolour gas-discharge elements)

  15. Menzerath-Altmann law for distinct word distribution analysis in a large text

    Science.gov (United States)

    Eroglu, Sertac

    2013-06-01

    The empirical law uncovered by Menzerath and formulated by Altmann, known as the Menzerath-Altmann law (henceforth the MA law), reveals the statistical distribution behavior of human language in various organizational levels. Building on previous studies relating organizational regularities in a language, we propose that the distribution of distinct (or different) words in a large text can effectively be described by the MA law. The validity of the proposition is demonstrated by examining two text corpora written in different languages not belonging to the same language family (English and Turkish). The results show not only that distinct word distribution behavior can accurately be predicted by the MA law, but that this result appears to be language-independent. This result is important not only for quantitative linguistic studies, but also may have significance for other naturally occurring organizations that display analogous organizational behavior. We also deliberately demonstrate that the MA law is a special case of the probability function of the generalized gamma distribution.

  16. Ribosome display: next-generation display technologies for production of antibodies in vitro.

    Science.gov (United States)

    He, Mingyue; Khan, Farid

    2005-06-01

    Antibodies represent an important and growing class of biologic research reagents and biopharmaceutical products. They can be used as therapeutics in a variety of diseases. With the rapid expansion of proteomic studies and biomarker discovery, there is a need for the generation of highly specific binding reagents to study the vast number of proteins encoded by the genome. Display technologies provide powerful tools for obtaining antibodies. Aside from the preservation of natural antibody repertoires, they are capable of exploiting diversity by DNA recombination to create very large libraries for selection of novel molecules. In contrast to in vivo immunization processes, display technologies allow selection of antibodies under in vitro-defined selection condition(s), resulting in enrichment of antibodies with desired properties from large populations. In addition, in vitro selection enables the isolation of antibodies against difficult antigens including self-antigens, and this can be applied to the generation of human antibodies against human targets. Display technologies can also be combined with DNA mutagenesis for antibody evolution in vitro. Some methods are amenable to automation, permitting high-throughput generation of antibodies. Ribosome display is considered as representative of the next generation of display technologies since it overcomes the limitations of cell-based display methods by using a cell-free system, offering advantages of screening larger libraries and continuously expanding new diversity during selection. Production of display-derived antibodies can be achieved by choosing one of a variety of prokaryotic and eukaryotic cell-based expression systems. In the near future, cell-free protein synthesis may be developed as an alternative for large-scale generation of antibodies.

  17. Viewport: An object-oriented approach to integrate workstation software for tile and stack mode display

    OpenAIRE

    Ghosh, Srinka; Andriole, Katherine P.; Avrin, David E.

    1997-01-01

    Diagnostic workstation design has migrated towards display presentation in one of two modes: tiled images or stacked images. It is our impression that the workstation setup or configuration in each of these two modes is rather distinct. We sought to establish a commonality to simplify software design, and to enable a single descriptor method to facilitate folder manager development of “hanging” protocols. All current workstation designs use a combination of “off-screen” and “on-screen” memory...

  18. Large-screen display industry: market and technology trends for direct view and projection displays

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1996-03-01

    Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.

  19. Scalable Resolution Display Walls

    KAUST Repository

    Leigh, Jason; Johnson, Andrew; Renambot, Luc; Peterka, Tom; Jeong, Byungil; Sandin, Daniel J.; Talandis, Jonas; Jagodic, Ratko; Nam, Sungwon; Hur, Hyejung; Sun, Yiwen

    2013-01-01

    This article will describe the progress since 2000 on research and development in 2-D and 3-D scalable resolution display walls that are built from tiling individual lower resolution flat panel displays. The article will describe approaches and trends in display hardware construction, middleware architecture, and user-interaction design. The article will also highlight examples of use cases and the benefits the technology has brought to their respective disciplines. © 1963-2012 IEEE.

  20. X-Windows Widget for Image Display

    Science.gov (United States)

    Deen, Robert G.

    2011-01-01

    XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.

  1. Study on the visibility of an electroluminescent display for automobiles; Jidoshayo EL display no shininsei

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, N; Harada, M; Idogaki, T [Denso Corp., Aichi (Japan)

    1997-10-01

    This report explores the visibility of an Electroluminescent (EL) display for automotive use. Displays for automobiles are exposed to the direct rays of the sun and forced to operate in wide temperature range. Therefore, luminous flux density by the lighting on EL display panel and operating environment temperature must be considered for the visibility evaluation. Sensory evaluation on the visibility and physical measurements such as contrast, chromaticity difference in accordance with the viewing angle change indicate that the visibility of the EL display for automobiles is advantageous over other displays. 6 refs., 11 figs., 1 tab.

  2. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  3. OLED displays and lighting

    CERN Document Server

    Koden, Mitsuhiro

    2017-01-01

    Organic light-emitting diodes (OLEDs) have emerged as the leading technology for the new display and lighting market. OLEDs are solid-state devices composed of thin films of organic molecules that create light with the application of electricity. OLEDs can provide brighter, crisper displays on electronic devices and use less power than conventional light-emitting diodes (LEDs) or liquid crystal displays (LCDs) used today. This book covers both the fundamentals and practical applications of flat and flexible OLEDs.

  4. Dichroic Liquid Crystal Displays

    Science.gov (United States)

    Bahadur, Birendra

    The following sections are included: * INTRODUCTION * DICHROIC DYES * Chemical Structure * Chemical and Photochemical Stability * THEORETICAL MODELLING * DEFECTS CAUSED BY PROLONGED LIGHT IRRADIATION * CHEMICAL STRUCTURE AND PHOTOSTABILITY * OTHER PARAMETERS AFFECTING PHOTOSTABILITY * CELL PREPARATION * DICHROIC PARAMETERS AND THEIR MEASUREMENTS * Order Parameter and Dichroic Ratio Of Dyes * Absorbance, Order Parameter and Dichroic Ratio Measurements * IMPACT OF DYE STRUCTURE AND LIQUID CRYSTAL HOST ON PHYSICAL PROPERTIES OF A DICHROIC MIXTURE * Order Parameter and Dichroic Ratio * EFFECT OF LENGTH OF DICHROIC DYES ON THE ORDER PARAMETER * EFFECT OF THE BREADTH OF DYE ON THE ORDER PARAMETER * EFFECT OF THE HOST ON THE ORDER PARAMETER * TEMPERATURE VARIATION OF THE ORDER PARAMETER OF DYES IN A LIQUID CRYSTAL HOST * IMPACT OF DYE CONCENTRATION ON THE ORDER PARAMETER * Temperature Range * Viscosity * Dielectric Constant and Anisotropy * Refractive Indices and Birefringence * solubility43,153-156 * Absorption Wavelength and Auxochromic Groups * Molecular Engineering of Dichroic Dyes * OPTICAL, ELECTRO-OPTICAL AND LIFE PARAMETERS * Colour And CIE Colour space120,160-166 * CIE 1931 COLOUR SPACE * CIE 1976 CHROMATICITY DIAGRAM * CIE UNIFORM COLOUR SPACES & COLOUR DIFFERENCE FORMULAE120,160-166 * Electro-Optical Parameters120 * LUMINANCE * CONTRAST AND CONTRAST RATIO * SWITCHING SPEED * Life Parameters and Failure Modes * DICHROIC MIXTURE FORMULATION * Monochrome Mixture * Black Mixture * ACHROMATIC BLACK MIXTURE FOR HEILMEIER DISPLAYS * Effect of Illuminant on Display Colour * Colour of the Field-On State * Effect of Dye Linewidth * Optimum Centroid Wavelengths * Effect of Dye Concentration * Mixture Formulation Using More Than Three Dyes * ACHROMATIC MIXTURE FOR WHITE-TAYLOR TYPE DISPLAYS * HEILMEIER DISPLAYS * Theoretical Modelling * Threshold Characteristic * Effects of Dye Concentration on Electro-optical Parameters * Effect of Cholesteric Doping * Effect of Alignment

  5. Crosstalk evaluation in stereoscopic displays

    NARCIS (Netherlands)

    Wang, L.; Teunissen, C.; Tu, Yan; Chen, Li; Zhang, P.; Zhang, T.; Heynderickx, I.E.J.

    2011-01-01

    Substantial progress in liquid-crystal display and polarization film technology has enabled several types of stereoscopic displays. Despite all progress, some image distortions still exist in these 3-D displays, of which interocular crosstalk - light leakage of the image for one eye to the other eye

  6. Quantum Distinction: Quantum Distinctiones!

    OpenAIRE

    Zeps, Dainis

    2009-01-01

    10 pages; How many distinctions, in Latin, quantum distinctiones. We suggest approach of anthropic principle based on anthropic reference system which should be applied equally both in theoretical physics and in mathematics. We come to principle that within reference system of life subject of mathematics (that of thinking) should be equated with subject of physics (that of nature). For this reason we enter notions of series of distinctions, quantum distinction, and argue that quantum distinct...

  7. Consortium for military LCD display procurement

    Science.gov (United States)

    Echols, Gregg

    2002-08-01

    International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.

  8. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  9. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix; Gregson, James; Wetzstein, Gordon; Raskar, Ramesh; Heidrich, Wolfgang

    2014-01-01

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  10. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  11. JTEC panel on display technologies in Japan

    Science.gov (United States)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  12. Australian Children's Understanding of Display Rules

    Science.gov (United States)

    Choy, Grace

    2009-01-01

    Cultural display rules govern the manifestation of emotional expressions. In compliance with display rules, the facial expressions displayed (i.e. apparent emotion) may be incongruent with the emotion experienced (i.e. real emotion). This study investigates Australian Caucasian children's understanding of display rules. A sample of 80 four year…

  13. The case for transparent depth display

    NARCIS (Netherlands)

    Kooi, F.L.

    2003-01-01

    Purpose: The continuing developments in display technology have resulted in the ability to present increasing amounts of data on computer displays. One of the coming break-throughs is generally believed to be the introduction of '3-D displays': displays with a true sense of depth. Though these types

  14. Anticancer Properties of Distinct Antimalarial Drug Classes

    Science.gov (United States)

    Hooft van Huijsduijnen, Rob; Guy, R. Kiplin; Chibale, Kelly; Haynes, Richard K.; Peitz, Ingmar; Kelter, Gerhard; Phillips, Margaret A.; Vennerstrom, Jonathan L.; Yuthavong, Yongyuth; Wells, Timothy N. C.

    2013-01-01

    We have tested five distinct classes of established and experimental antimalarial drugs for their anticancer potential, using a panel of 91 human cancer lines. Three classes of drugs: artemisinins, synthetic peroxides and DHFR (dihydrofolate reductase) inhibitors effected potent inhibition of proliferation with IC50s in the nM- low µM range, whereas a DHODH (dihydroorotate dehydrogenase) and a putative kinase inhibitor displayed no activity. Furthermore, significant synergies were identified with erlotinib, imatinib, cisplatin, dasatinib and vincristine. Cluster analysis of the antimalarials based on their differential inhibition of the various cancer lines clearly segregated the synthetic peroxides OZ277 and OZ439 from the artemisinin cluster that included artesunate, dihydroartemisinin and artemisone, and from the DHFR inhibitors pyrimethamine and P218 (a parasite DHFR inhibitor), emphasizing their shared mode of action. In order to further understand the basis of the selectivity of these compounds against different cancers, microarray-based gene expression data for 85 of the used cell lines were generated. For each compound, distinct sets of genes were identified whose expression significantly correlated with compound sensitivity. Several of the antimalarials tested in this study have well-established and excellent safety profiles with a plasma exposure, when conservatively used in malaria, that is well above the IC50s that we identified in this study. Given their unique mode of action and potential for unique synergies with established anticancer drugs, our results provide a strong basis to further explore the potential application of these compounds in cancer in pre-clinical or and clinical settings. PMID:24391728

  15. Anticancer properties of distinct antimalarial drug classes.

    Directory of Open Access Journals (Sweden)

    Rob Hooft van Huijsduijnen

    Full Text Available We have tested five distinct classes of established and experimental antimalarial drugs for their anticancer potential, using a panel of 91 human cancer lines. Three classes of drugs: artemisinins, synthetic peroxides and DHFR (dihydrofolate reductase inhibitors effected potent inhibition of proliferation with IC50s in the nM- low µM range, whereas a DHODH (dihydroorotate dehydrogenase and a putative kinase inhibitor displayed no activity. Furthermore, significant synergies were identified with erlotinib, imatinib, cisplatin, dasatinib and vincristine. Cluster analysis of the antimalarials based on their differential inhibition of the various cancer lines clearly segregated the synthetic peroxides OZ277 and OZ439 from the artemisinin cluster that included artesunate, dihydroartemisinin and artemisone, and from the DHFR inhibitors pyrimethamine and P218 (a parasite DHFR inhibitor, emphasizing their shared mode of action. In order to further understand the basis of the selectivity of these compounds against different cancers, microarray-based gene expression data for 85 of the used cell lines were generated. For each compound, distinct sets of genes were identified whose expression significantly correlated with compound sensitivity. Several of the antimalarials tested in this study have well-established and excellent safety profiles with a plasma exposure, when conservatively used in malaria, that is well above the IC50s that we identified in this study. Given their unique mode of action and potential for unique synergies with established anticancer drugs, our results provide a strong basis to further explore the potential application of these compounds in cancer in pre-clinical or and clinical settings.

  16. New ultraportable display technology and applications

    Science.gov (United States)

    Alvelda, Phillip; Lewis, Nancy D.

    1998-08-01

    MicroDisplay devices are based on a combination of technologies rooted in the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates. Customized diffraction grating and optical distortion correction technology for lens-system compensation allow the elimination of many lenses and systems-level components. The MicroDisplay Corporation's miniature integrated information display technology is rapidly leading to many new defense and commercial applications. There are no moving parts in MicroDisplay substrates, and the fabrication of the color generating gratings, already part of the CMOS circuit fabrication process, is effectively cost and manufacturing process-free. The entire suite of the MicroDisplay Corporation's technologies was devised to create a line of application- specific integrated circuit single-chip display systems with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass and head mounted displays, pagers and Personal Communication Services hand-sets, and wristwatch-mounted video phones are among the may target commercial markets for MicroDisplay technology. Defense applications range from Maintenance and Repair support, to night-vision systems, to portable projectors for mobile command and control centers.

  17. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  18. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity

    DEFF Research Database (Denmark)

    Wendel, Sofie; Christian Fischer, Emil; Martinez, Virginia

    2016-01-01

    Background: Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay...... to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency.Conclusions: We have developed an inexpensive and easy read-out assay for surface display using...... nanobody: GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies...

  19. Reconfigurable Full-Page Braille Displays

    Science.gov (United States)

    Garner, H. Douglas

    1994-01-01

    Electrically actuated braille display cells of proposed type arrayed together to form full-page braille displays. Like other braille display cells, these provide changeable patterns of bumps driven by digitally recorded text stored on magnetic tapes or in solid-state electronic memories. Proposed cells contain electrorheological fluid. Viscosity of such fluid increases in strong electrostatic field.

  20. Standardized access, display, and retrieval of medical video

    Science.gov (United States)

    Bellaire, Gunter; Steines, Daniel; Graschew, Georgi; Thiel, Andreas; Bernarding, Johannes; Tolxdorff, Thomas; Schlag, Peter M.

    1999-05-01

    The system presented here enhances documentation and data- secured, second-opinion facilities by integrating video sequences into DICOM 3.0. We present an implementation for a medical video server extended by a DICOM interface. Security mechanisms conforming with DICOM are integrated to enable secure internet access. Digital video documents of diagnostic and therapeutic procedures should be examined regarding the clip length and size necessary for second opinion and manageable with today's hardware. Image sources relevant for this paper include 3D laparoscope, 3D surgical microscope, 3D open surgery camera, synthetic video, and monoscopic endoscopes, etc. The global DICOM video concept and three special workplaces of distinct applications are described. Additionally, an approach is presented to analyze the motion of the endoscopic camera for future automatic video-cutting. Digital stereoscopic video sequences are especially in demand for surgery . Therefore DSVS are also integrated into the DICOM video concept. Results are presented describing the suitability of stereoscopic display techniques for the operating room.

  1. Display-management system for MFTF

    International Nuclear Information System (INIS)

    Nelson, D.O.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is controlled by 65 local control microcomputers which are supervised by a local network of nine 32-bit minicomputers. Associated with seven of the nine computers are state-of-the-art graphics devices, each with extensive local processing capability. These devices provide the means for an operator to interact with the control software running on the minicomputers. It is critical that the information the operator views accurately reflects the current state of the experiment. This information is integrated into dynamically changing pictures called displays. The primary organizational component of the display system is the software-addressable segment. The segments created by the display creation software are managed by display managers associated with each graphics device. Each display manager uses sophisticated storage management mechanisms to keep the proper segments resident in the local graphics device storage

  2. Data display with the Q system

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1979-01-01

    The Q data-acquisition system for PDP-11 mini-computers at the Clinton P. Anderson Meson Physics Facility (LAMPF) provides experimenters with basic tools for on-line data display. Tasks are available to plot one- and two-parameter histograms on Tektronix 4000 series storage-tube terminals. The histograms to be displayed and the display format may be selected with simple keyboard commands. A task is also available to create and display live two-parameter scatter plots for any acquired or calculated quantities. Other tasks in the system manage the display data base, list display parameters and histogram contents on hardcopy devices, and save core histograms on disk or tape for off-line analysis. 8 figures

  3. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity.

    Science.gov (United States)

    Wendel, Sofie; Fischer, Emil C; Martínez, Virginia; Seppälä, Susanna; Nørholm, Morten H H

    2016-05-03

    Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay for evaluating and developing surface display systems is missing. Using a single domain antibody (also called nanobody) with high affinity for green fluorescent protein (GFP), we constructed a system that allows for fast, fluorescence-based detection of displayed proteins. The outer membrane hybrid protein LppOmpA and the autotransporter C-IgAP exposed the nanobody on the surface of Escherichia coli with very different efficiency. Both anchors were capable of functionally displaying the enzyme Chitinase A as a fusion with the nanobody, and this considerably increased expression levels compared to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency. We have developed an inexpensive and easy read-out assay for surface display using nanobody:GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies on the mechanism of protein transport to the surface of living cells, as well as the optimisation of applications in industrial biotech.

  4. Human engineering evaluation of Hamaoka No. 3 advanced control room CRT display system

    International Nuclear Information System (INIS)

    Okajima, Hiroyuki; Ito, Takahiko; Noguchi, Yoshihiro; Kabasawa, Yoshihiko

    1985-01-01

    As the central control board of Hamaoka No. 3 plant, a new type control board was adopted for the purpose of powerfully supporting the general judgement function of operators by processing enormous plant data in the normal operation and at the time of an accident with a computer, and displaying the results on CRT screens in the summarized form. Recently, the evaluation of this new control board was carried out by ergonomical techniques, and it was confirmed that the initial objective has been attained. Besides, the criteria for the ergonomical evaluation of central control boards mainly for CRT display were determined, and the contents of design were able to be systematically evaluated and verified. As the ergonomical design of the central control board, the easy distinction of the function of switches, the easy confirmation of system constitution by mimics, the use of CRTs, the easy identification of operation pilot lamps, alarms, instruments and so on were considered. The central control board consists of the main control board, auxiliary control boards and vertical boards, and 12 CRTs are installed. (Kako, I.)

  5. Temporomandibular joint formation requires two distinct hedgehog-dependent steps.

    Science.gov (United States)

    Purcell, Patricia; Joo, Brian W; Hu, Jimmy K; Tran, Pamela V; Calicchio, Monica L; O'Connell, Daniel J; Maas, Richard L; Tabin, Clifford J

    2009-10-27

    We conducted a genetic analysis of the developing temporo-mandibular or temporomandi-bular joint (TMJ), a highly specialized synovial joint that permits movement and function of the mammalian jaw. First, we used laser capture microdissection to perform a genome-wide expression analysis of each of its developing components. The expression patterns of genes identified in this screen were examined in the TMJ and compared with those of other synovial joints, including the shoulder and the hip joints. Striking differences were noted, indicating that the TMJ forms via a distinct molecular program. Several components of the hedgehog (Hh) signaling pathway are among the genes identified in the screen, including Gli2, which is expressed specifically in the condyle and in the disk of the developing TMJ. We found that mice deficient in Gli2 display aberrant TMJ development such that the condyle loses its growth-plate-like cellular organization and no disk is formed. In addition, we used a conditional strategy to remove Smo, a positive effector of the Hh signaling pathway, from chondrocyte progenitors. This cell autonomous loss of Hh signaling allows for disk formation, but the resulting structure fails to separate from the condyle. Thus, these experiments establish that Hh signaling acts at two distinct steps in disk morphogenesis, condyle initiation, and disk-condyle separation and provide a molecular framework for future studies of the TMJ.

  6. Helmet-Mounted Display Design Guide

    Science.gov (United States)

    1997-11-03

    on openStack create menu "CSHMD" set the menuitems of "CSHMD" to "(Main Menu; References;-; Definitions;Display Criteria;Display Formats;Display Modes...34Macintosh" then put ":" into dirSep else put "V’ into dirSep put stackPathO&"Resource"&dirSep into gResPath put 0 into gXRef end openStack on

  7. Ruggedized Full-Color Flexible OLED Display

    National Research Council Canada - National Science Library

    Hack, Michael

    2003-01-01

    .... The team comprised Universal Display Corporation, Princeton University, the University of Southern California, Penn State University, L3 Displays and Vitex Systems, and was led by Universal Display Corporation (PI: Michael Hack...

  8. A variable-collimation display system

    Science.gov (United States)

    Batchko, Robert; Robinson, Sam; Schmidt, Jack; Graniela, Benito

    2014-03-01

    Two important human depth cues are accommodation and vergence. Normally, the eyes accommodate and converge or diverge in tandem; changes in viewing distance cause the eyes to simultaneously adjust both focus and orientation. However, ambiguity between accommodation and vergence cues is a well-known limitation in many stereoscopic display technologies. This limitation also arises in state-of-the-art full-flight simulator displays. In current full-flight simulators, the out-the-window (OTW) display (i.e., the front cockpit window display) employs a fixed collimated display technology which allows the pilot and copilot to perceive the OTW training scene without angular errors or distortions; however, accommodation and vergence cues are limited to fixed ranges (e.g., ~ 20 m). While this approach works well for long-range, the ambiguity of depth cues at shorter range hinders the pilot's ability to gauge distances in critical maneuvers such as vertical take-off and landing (VTOL). This is the first in a series of papers on a novel, variable-collimation display (VCD) technology that is being developed under NAVY SBIR Topic N121-041 funding. The proposed VCD will integrate with rotary-wing and vertical take-off and landing simulators and provide accurate accommodation and vergence cues for distances ranging from approximately 3 m outside the chin window to ~ 20 m. A display that offers dynamic accommodation and vergence could improve pilot safety and training, and impact other applications presently limited by lack of these depth cues.

  9. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  10. Basics of Antibody Phage Display Technology.

    Science.gov (United States)

    Ledsgaard, Line; Kilstrup, Mogens; Karatt-Vellatt, Aneesh; McCafferty, John; Laustsen, Andreas H

    2018-06-09

    Antibody discovery has become increasingly important in almost all areas of modern medicine. Different antibody discovery approaches exist, but one that has gained increasing interest in the field of toxinology and antivenom research is phage display technology. In this review, the lifecycle of the M13 phage and the basics of phage display technology are presented together with important factors influencing the success rates of phage display experiments. Moreover, the pros and cons of different antigen display methods and the use of naïve versus immunized phage display antibody libraries is discussed, and selected examples from the field of antivenom research are highlighted. This review thus provides in-depth knowledge on the principles and use of phage display technology with a special focus on discovery of antibodies that target animal toxins.

  11. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  12. Display rules versus display autonomy: emotion regulation, emotional exhaustion, and task performance in a call center simulation.

    Science.gov (United States)

    Goldberg, Lori Sideman; Grandey, Alicia A

    2007-07-01

    "Service with a smile" is satisfying for the customer, but such display rules may be costly to the employee and the organization. Most previous research on such costs has used self-reported and cross-sectional designs. The authors use an experimental approach to test tenets of resource depletion theories; specifically, whether the self-regulation of emotions required by display rules depletes energy and attentional resources during a service encounter. Using a call center simulation with three "customer" interactions, the authors found that participants given positive display rules (e.g., be enthusiastic and hide frustration) reported more postsimulation exhaustion and made more errors on the order form compared to those with display autonomy. Customer hostility during one of the calls also increased exhaustion overall and the number of errors during that specific call, though proposed interactions with display rules were not supported. Surface-level emotion regulation, but not deep-level, was the mechanism for the energy depletion effect of display rules, while display rules had a direct effect on performance decrements. Theoretical and practical implications for display rules as part of job requirements are discussed. Copyright 2007 APA

  13. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  14. Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots

    Science.gov (United States)

    2010-04-01

    you are performing the low crawl 4.25 5.00 Drive the robot while you are negotiating the hill 6.00 5.00 Drive the robot while you are climbing the... stairs 4.67 5.00 Drive the robot while you are walking 5.70 5.27 HMD It was fairly doable. 1 When you’re looking through the lens, it’s not...Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots by Elizabeth S. Redden, Rodger A. Pettitt

  15. Distinctly visible right upper lobe bronchus on the lateral chest: A clue to adolescent cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Reinig, J.W.; Sanchez, F.W.; Thomason, D.M.; Gobien, R.P.

    1985-05-01

    Radiographic differentiation between cystic fibrosis and asthma presenting in teenagers and young adults can be difficult. Many patients with a late presentation of cystic fibrosis display minimal changes on a chest radiograph. However, a large majority (90%) of cystic fibrosis patients with an essentially normal PA chest radiograph will have a distinctly outlined orifice of right upper lobe bronchus on a lateral chest film as opposed to a small number of asthmatics (25%) or normal patients (18%). This observation correlates well with the pathologic finding that the initial pulmonary involvement in cystic fibrosis is typically in the right upper lobe in adolescents. Teenager or young adult patients presenting with a history of repeated respiratory infections, asthma-like symptoms and a distinctly visible right upper lobe bronchus on a lateral chest film should be sweat-tested to exclude cystic fibrosis.

  16. Liquid crystal displays with plastic substrates

    Science.gov (United States)

    Lueder, Ernst H.

    1998-04-01

    Plastic substrates for the cells of displays exhibit only 1/6 of the weight of glass substrates; they are virtually unbreakable; their flexibility allows the designer to give them a shape suppressing reflections, to realize a display board on a curved surface or meeting the requirements for an appealing styling; displays with plastics are thinner which provides a wider viewing angle. These features render them attractive for displays in portable systems such as mobile phones, pagers, smart cards, personal digital assistants (PDAs) and portable computers. Reflective displays are especially attractive as they don't need a back light. The most important requirements are the protection of plastics against gas permeation and chemical agents, the prevention of layers on plastics to crack or peel off when the plastic is bent and the development of low temperature thin film processes because the plastics, as a rule, only tolerate temperatures below 150 degrees Celsius. Bistable reflective FLC- and PSCT-displays with plastic substrates will be introduced. Special sputtered SiO2-orientation layers preserve the displayed information even if pressure or torsion is applied. MIM-addressed PDLC-displays require additional Al- or Ti-layers which provide the necessary ductility. Sputtered or PECVD-generated TFTs can be fabricated on plastics at temperatures below 150 degrees Celsius.

  17. Are children conservative, liberal, or metacognitive? Preliminary evidence for the involvement of the distinctiveness heuristic in decision making.

    Science.gov (United States)

    Geurten, Marie; Willems, Sylvie; Meulemans, Thierry

    2015-04-01

    The experiment tested whether young children are able to reduce their false recognition rate after distinctive encoding by implementing a strategic metacognitive rule. The participants, 72 children aged 4, 6, and 9 years, studied two lists of unrelated items. One of these lists was visually displayed (picture condition), whereas the other was presented auditorily (word condition). After each study phase, participants completed recognition tests. Finally, they answered questions about their explicit knowledge of the distinctive encoding effect. The results revealed that even the youngest children in our sample showed a smaller proportion of intrusions in the picture condition than in the word condition. Furthermore, the results of the signal detection analyses were consistent with the hypothesis that the lower rate of false recognitions after picture encoding results from the implementation of a conservative response criterion based on metacognitive expectations (distinctiveness heuristic). Moreover, the absence of correlation between children's explicit knowledge of the distinctiveness rule and their effective use of this metacognitive heuristic seems to indicate that its involvement in memory decisions could be mediated by implicit mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Plant state display device

    International Nuclear Information System (INIS)

    Kadota, Kazuo; Ito, Toshiichiro.

    1994-01-01

    The device of the present invention conducts information processing suitable for a man to solve a problem in a plant such as a nuclear power plant incorporating a great amount of information, where safety is required and provides information to an operator. Namely, theories and rules with respect to the flow and balanced state of materials and energy upon plant start-up, and a vapor cycle of operation fluids are symbolized and displayed on the display screen of the device. Then, the display of the plant information suitable to the information processing for a man to dissolve problems is provided. Accordingly, a mechanism for analyzing a purpose of the plant is made more definite, thereby enabling to prevent an erroneous judgement of an operator and occurrence of plant troubles. In addition, a simular effect can also be expected when the theories and rules with respect to the flow and the balanced state of materials and energy and thermohydrodynamic behavior of the operation fluids in a state of after-heat removing operation during shutdown of the plant are symbolized and displayed. (I.S.)

  19. Efficient Imaging and Real-Time Display of Scanning Ion Conductance Microscopy Based on Block Compressive Sensing

    Science.gov (United States)

    Li, Gongxin; Li, Peng; Wang, Yuechao; Wang, Wenxue; Xi, Ning; Liu, Lianqing

    2014-07-01

    Scanning Ion Conductance Microscopy (SICM) is one kind of Scanning Probe Microscopies (SPMs), and it is widely used in imaging soft samples for many distinctive advantages. However, the scanning speed of SICM is much slower than other SPMs. Compressive sensing (CS) could improve scanning speed tremendously by breaking through the Shannon sampling theorem, but it still requires too much time in image reconstruction. Block compressive sensing can be applied to SICM imaging to further reduce the reconstruction time of sparse signals, and it has another unique application that it can achieve the function of image real-time display in SICM imaging. In this article, a new method of dividing blocks and a new matrix arithmetic operation were proposed to build the block compressive sensing model, and several experiments were carried out to verify the superiority of block compressive sensing in reducing imaging time and real-time display in SICM imaging.

  20. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  1. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  2. MRNIDX - Marine Data Index: Database Description, Operation, Retrieval, and Display

    Science.gov (United States)

    Paskevich, Valerie F.

    1982-01-01

    A database referencing the location and content of data stored on magnetic medium was designed to assist in the indexing of time-series and spatially dependent marine geophysical data collected or processed by the U. S. Geological Survey. The database was designed and created for input to the Geologic Retrieval and Synopsis Program (GRASP) to allow selective retrievals of information pertaining to location of data, data format, cruise, geographical bounds and collection dates of data. This information is then used to locate the stored data for administrative purposes or further processing. Database utilization is divided into three distinct operations. The first is the inventorying of the data and the updating of the database, the second is the retrieval of information from the database, and the third is the graphic display of the geographical boundaries to which the retrieved information pertains.

  3. SNS online display technologies for EPICS

    International Nuclear Information System (INIS)

    Kasemir, K.U.; Chen, X.; Purcell, J.; Danilova, E.

    2012-01-01

    The ubiquitousness of web clients from personal computers to cell phones results in a growing demand for web-based access to control system data. At the Oak Ridge National Laboratory Spallation Neutron Source (SNS) we have investigated different technical approaches to provide read access to data in the Experimental Physics and Industrial Control System (EPICS) for a wide variety of web client devices. The core web technology, HTTP, is less than ideal for online control system displays. Appropriate use of Ajax, especially the Long Poll paradigm, can alleviate fundamental HTTP limitations. The SNS Status web uses basic Ajax technology to generate generic displays for a wide audience. The Dashboard uses Long Poll and more client-side Java-Script to offer more customization and faster updates for users that need specialized displays. The Web OPI uses RAP for web access to any BOY display, offering utmost flexibility because users can create their own BOY displays in CSS. These three approaches complement each other. Users can access generic status displays with zero effort, invest time in creating their fully customized displays for the Web OPI, or use the Dashboard as an intermediate solution

  4. Dyes for displays

    Science.gov (United States)

    Claussen, U.

    1984-01-01

    The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.

  5. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  6. Performance of NCAP projection displays

    Science.gov (United States)

    Jones, Philip J.; Tomita, Akira; Wartenberg, Mark

    1991-08-01

    Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.

  7. Compressive multi-mode superresolution display

    KAUST Repository

    Heide, Felix

    2014-01-01

    Compressive displays are an emerging technology exploring the co-design of new optical device configurations and compressive computation. Previously, research has shown how to improve the dynamic range of displays and facilitate high-quality light field or glasses-free 3D image synthesis. In this paper, we introduce a new multi-mode compressive display architecture that supports switching between 3D and high dynamic range (HDR) modes as well as a new super-resolution mode. The proposed hardware consists of readily-available components and is driven by a novel splitting algorithm that computes the pixel states from a target high-resolution image. In effect, the display pixels present a compressed representation of the target image that is perceived as a single, high resolution image. © 2014 Optical Society of America.

  8. Nuclear image display controller

    International Nuclear Information System (INIS)

    Roth, D.A.

    1985-01-01

    In a nuclear imaging system the digitized x and y coordinates of gamma ray photon emission events address memory locations corresponding to the coordinates. The respective locations are incremented each time they are addressed so at the end of a selected time or event count period the locations contain digital values or raw data corresponding to the intensity of pixels comprising an image frame. The raw data for a frame is coupled to one input of an arithmetic logic unit (ALU) whose output is coupled to a display controller memory. The output of the controller memory is coupled to another ALU input with a feedback bus and is also coupled to a further signal processing circuit which includes means for converting processed data to analog video signals for television display. The ALU is selectively controlled to let raw image data pass through to the display controllor memory or alternately to add (or subtract) raw data for the last image frame developed to the raw data for preceding frames held in the display controller to thereby produce the visual effect on the television screen of an isotope flowing through anatomy

  9. Dimensions of Situatedness for Digital Public Displays

    Directory of Open Access Journals (Sweden)

    Rui José

    2014-01-01

    Full Text Available Public displays are often strongly situated signs deeply embedded in their physical, social, and cultural setting. Understanding how the display is coupled with on-going situations, its level of situatedness, provides a key element for the interpretation of the displays themselves but is also an element for the interpretation of place, its situated practices, and its social context. Most digital displays, however, do not achieve the same sense of situatedness that seems so natural in their nondigital counterparts. This paper investigates people’s perception of situatedness when considering the connection between public displays and their context. We have collected over 300 photos of displays and conducted a set of analysis tasks involving focus groups and structured interviews with 15 participants. The contribution is a consolidated list of situatedness dimensions that should provide a valuable resource for reasoning about situatedness in digital displays and informing the design and development of display systems.

  10. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  11. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs.......Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  12. Microencapsulated Electrophoretic Films for Electronic Paper Displays

    Science.gov (United States)

    Amundson, Karl

    2003-03-01

    Despite the dominance of liquid crystal displays, they do not perform some functions very well. While backlit liquid crystal displays can offer excellent color performance, they wash out in bright lighting and suffer from high power consumption. Reflective liquid crystal displays have limited brightness, making these devices challenging to read for long periods of time. Flexible liquid crystal displays are difficult to manufacture and keep stable. All of these attributes (long battery lifetime, bright reflective appearance, compatibility with flexible substrates) are traits that would be found in an ideal electronic paper display - an updateable substitute for paper that could be employed in electronic books, newspapers, and other applications. I will discuss technologies that are being developed for electronic-paper-like displays, and especially on particle-based technologies. A microencapsulated electrophoretic display technology is being developed at the E Ink corporation. This display film offers offer high brightness and an ink-on-paper appearance, compatibility with flexible substrates, and image stability that can lead to very low power consumption. I will present some of the physical and chemical challenges associated with making display films with high performance.

  13. Revisiting the debate on the relationship between display rules and performance: considering the explicitness of display rules.

    Science.gov (United States)

    Christoforou, Paraskevi S; Ashforth, Blake E

    2015-01-01

    We argue that the strength with which the organization communicates expectations regarding the appropriate emotional expression toward customers (i.e., explicitness of display rules) has an inverted U-shaped relationship with service delivery behaviors, customer satisfaction, and sales performance. Further, we argue that service organizations need a particular blend of explicitness of display rules and role discretion for the purpose of optimizing sales performance. As hypothesized, findings from 2 samples of salespeople suggest that either high or low explicitness of display rules impedes service delivery behaviors and sales performance, which peaks at moderate explicitness of display rules and high role discretion. The findings also suggest that the explicitness of display rules has a positive relationship with customer satisfaction. (c) 2015 APA, all rights reserved.

  14. The distinctly visible right upper lobe bronchus on the lateral chest: A clue to adolescent cystic fibrosis

    International Nuclear Information System (INIS)

    Reinig, J.W.; Sanchez, F.W.; Thomason, D.M.; Gobien, R.P.

    1985-01-01

    Radiographic differentiation between cystic fibrosis and asthma presenting in teenagers and young adults can be difficult. Many patients with a late presentation of cystic fibrosis display minimal changes on a chest radiograph. However, a large majority (90%) of cystic fibrosis patients with an essentially normal PA chest radiograph will have a distinctly outlined orifice of right upper lobe bronchus on a lateral chest film as opposed to a small number of asthmatics (25%) or normal patients (18%). This observation correlates well with the pathologic finding that the initial pulmonary involvement in cystic fibrosis is typically in the right upper lobe in adolescents. Teenager or young adult patients presenting with a history of repeated respiratory infections, asthma-like symptoms and a distinctly visible right upper lobe bronchus on a lateral chest film should be sweat-tested to exclude cystic fibrosis. (orig.)

  15. Viewport: an object-oriented approach to integrate workstation software for tile and stack mode display.

    Science.gov (United States)

    Ghosh, S; Andriole, K P; Avrin, D E

    1997-08-01

    Diagnostic workstation design has migrated towards display presentation in one of two modes: tiled images or stacked images. It is our impression that the workstation setup or configuration in each of these two modes is rather distinct. We sought to establish a commonality to simplify software design, and to enable a single descriptor method to facilitate folder manager development of "hanging" protocols. All current workstation designs use a combination of "off-screen" and "on-screen" memory whether or not they use a dedicated display subsystem, or merely a video board. Most diagnostic workstations also have two or more monitors. Our central concept is that of a "logical" viewport that can be smaller than, the same size as, or larger than a single monitor. Each port "views" an image data sequence loaded into offscreen memory. Each viewport can display one or more images in sequence in a one-on-one or traditionally tiled presentation. Viewports can be assigned to the available monitor "real estate" in any manner that fits. For example, a single sequence computed tomography (CT) study could be displayed across all monitors in a tiled appearance by assigning a single large viewport to the monitors. At the other extreme, a multisequence magnetic resonance (MR) study could be compared with a similar previous study by assigning four viewports to each monitor, single image display per viewport, and assigning four of the sequences of the current study to the left monitor viewports, and four of the earlier study to the right monitor viewports. Ergonomic controls activate scrolling through the off-screen image sequence data. Workstation folder manager hanging protocols could then specify viewports, number of images per viewport, and the automatic assignment of appropriately named sequences of current and previous studies to the viewports on a radiologist-specific basis. Furthermore, software development is simplified by common base objects and methods of the tile and stack

  16. Software for Minsk-32 display station

    International Nuclear Information System (INIS)

    Belyaeva, L.M.; Gangrskaya, O.G.; Manno, I.; Fefilov, B.V.; Ehsenski, J.

    1976-01-01

    The mathematical provision is described of the Minsk-32 display station. Described is the application of editing program DOSE, assembler translator SLANG and program display-focal. Program DOSE permits to edit the texts with the aid of a rester display on Minsk-32 magnetic tape. The program system permits to use a disk monitor system

  17. An Investigation of Interval Management Displays

    Science.gov (United States)

    Swieringa, Kurt A.; Wilson, Sara R.; Shay, Rick

    2015-01-01

    NASA's first Air Traffic Management (ATM) Technology Demonstration (ATD-1) was created to transition the most mature ATM technologies from the laboratory to the National Airspace System. One selected technology is Interval Management (IM), which uses onboard aircraft automation to compute speeds that help the flight crew achieve and maintain precise spacing behind a preceding aircraft. Since ATD-1 focuses on a near-term environment, the ATD-1 flight demonstration prototype requires radio voice communication to issue an IM clearance. Retrofit IM displays will enable pilots to both enter information into the IM avionics and monitor IM operation. These displays could consist of an interface to enter data from an IM clearance and also an auxiliary display that presents critical information in the primary field-of-view. A human-in-the-loop experiment was conducted to examine usability and acceptability of retrofit IM displays, which flight crews found acceptable. Results also indicate the need for salient alerting when new speeds are generated and the desire to have a primary field of view display available that can display text and graphic trend indicators.

  18. Distributed rendering for multiview parallax displays

    Science.gov (United States)

    Annen, T.; Matusik, W.; Pfister, H.; Seidel, H.-P.; Zwicker, M.

    2006-02-01

    3D display technology holds great promise for the future of television, virtual reality, entertainment, and visualization. Multiview parallax displays deliver stereoscopic views without glasses to arbitrary positions within the viewing zone. These systems must include a high-performance and scalable 3D rendering subsystem in order to generate multiple views at real-time frame rates. This paper describes a distributed rendering system for large-scale multiview parallax displays built with a network of PCs, commodity graphics accelerators, multiple projectors, and multiview screens. The main challenge is to render various perspective views of the scene and assign rendering tasks effectively. In this paper we investigate two different approaches: Optical multiplexing for lenticular screens and software multiplexing for parallax-barrier displays. We describe the construction of large-scale multi-projector 3D display systems using lenticular and parallax-barrier technology. We have developed different distributed rendering algorithms using the Chromium stream-processing framework and evaluate the trade-offs and performance bottlenecks. Our results show that Chromium is well suited for interactive rendering on multiview parallax displays.

  19. Spielräume schulischer Displays

    Directory of Open Access Journals (Sweden)

    Antje Lehn

    2014-03-01

    Full Text Available Antje Lehn zeigt in ihrem Beitrag, wie durch einen erweiterten Display-Begriff in der Schulklasse durch konkrete Projekte Frontalunterricht unterwandert und das Klassenzimmer zu einem ergebnisoffenen Handlungsraum umgestaltet werden kann. Auch Decken, Spiegel, Tische und Spinde sind Displays ...

  20. Performance evaluation of a kinesthetic-tactual display

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.; Dunn, R. S.

    1982-01-01

    Simulator studies demonstrated the feasibility of using kinesthetic-tactual (KT) displays for providing collective and cyclic command information, and suggested that KT displays may increase pilot workload capability. A dual-axis laboratory tracking task suggested that beyond reduction in visual scanning, there may be additional sensory or cognitive benefits to the use of multiple sensory modalities. Single-axis laboratory tracking tasks revealed performance with a quickened KT display to be equivalent to performance with a quickened visual display for a low frequency sum-of-sinewaves input. In contrast, an unquickened KT display was inferior to an unquickened visual display. Full scale simulator studies and/or inflight testing are recommended to determine the generality of these results.

  1. Effect of display size on visual attention.

    Science.gov (United States)

    Chen, I-Ping; Liao, Chia-Ning; Yeh, Shih-Hao

    2011-06-01

    Attention plays an important role in the design of human-machine interfaces. However, current knowledge about attention is largely based on data obtained when using devices of moderate display size. With advancement in display technology comes the need for understanding attention behavior over a wider range of viewing sizes. The effect of display size on test participants' visual search performance was studied. The participants (N = 12) performed two types of visual search tasks, that is, parallel and serial search, under three display-size conditions (16 degrees, 32 degrees, and 60 degrees). Serial, but not parallel, search was affected by display size. In the serial task, mean reaction time for detecting a target increased with the display size.

  2. Exploring interaction with 3D volumetric displays

    Science.gov (United States)

    Grossman, Tovi; Wigdor, Daniel; Balakrishnan, Ravin

    2005-03-01

    Volumetric displays generate true volumetric 3D images by actually illuminating points in 3D space. As a result, viewing their contents is similar to viewing physical objects in the real world. These displays provide a 360 degree field of view, and do not require the user to wear hardware such as shutter glasses or head-trackers. These properties make them a promising alternative to traditional display systems for viewing imagery in 3D. Because these displays have only recently been made available commercially (e.g., www.actuality-systems.com), their current use tends to be limited to non-interactive output-only display devices. To take full advantage of the unique features of these displays, however, it would be desirable if the 3D data being displayed could be directly interacted with and manipulated. We investigate interaction techniques for volumetric display interfaces, through the development of an interactive 3D geometric model building application. While this application area itself presents many interesting challenges, our focus is on the interaction techniques that are likely generalizable to interactive applications for other domains. We explore a very direct style of interaction where the user interacts with the virtual data using direct finger manipulations on and around the enclosure surrounding the displayed 3D volumetric image.

  3. Volume scanning three-dimensional display with an inclined two-dimensional display and a mirror scanner

    Science.gov (United States)

    Miyazaki, Daisuke; Kawanishi, Tsuyoshi; Nishimura, Yasuhiro; Matsushita, Kenji

    2001-11-01

    A new three-dimensional display system based on a volume-scanning method is demonstrated. To form a three-dimensional real image, an inclined two-dimensional image is rapidly moved with a mirror scanner while the cross-section patterns of a three-dimensional object are displayed sequentially. A vector-scan CRT display unit is used to obtain a high-resolution image. An optical scanning system is constructed with concave mirrors and a galvanometer mirror. It is confirmed that three-dimensional images, formed by the experimental system, satisfy all the criteria for human stereoscopic vision.

  4. Genes expressed in specific areas of the human fetal cerebral cortex display distinct patterns of evolution.

    Directory of Open Access Journals (Sweden)

    Nelle Lambert

    2011-03-01

    Full Text Available The developmental mechanisms through which the cerebral cortex increased in size and complexity during primate evolution are essentially unknown. To uncover genetic networks active in the developing cerebral cortex, we combined three-dimensional reconstruction of human fetal brains at midgestation and whole genome expression profiling. This novel approach enabled transcriptional characterization of neurons from accurately defined cortical regions containing presumptive Broca and Wernicke language areas, as well as surrounding associative areas. We identified hundreds of genes displaying differential expression between the two regions, but no significant difference in gene expression between left and right hemispheres. Validation by qRTPCR and in situ hybridization confirmed the robustness of our approach and revealed novel patterns of area- and layer-specific expression throughout the developing cortex. Genes differentially expressed between cortical areas were significantly associated with fast-evolving non-coding sequences harboring human-specific substitutions that could lead to divergence in their repertoires of transcription factor binding sites. Strikingly, while some of these sequences were accelerated in the human lineage only, many others were accelerated in chimpanzee and/or mouse lineages, indicating that genes important for cortical development may be particularly prone to changes in transcriptional regulation across mammals. Genes differentially expressed between cortical regions were also enriched for transcriptional targets of FoxP2, a key gene for the acquisition of language abilities in humans. Our findings point to a subset of genes with a unique combination of cortical areal expression and evolutionary patterns, suggesting that they play important roles in the transcriptional network underlying human-specific neural traits.

  5. Refreshing Refreshable Braille Displays.

    Science.gov (United States)

    Russomanno, Alexander; O'Modhrain, Sile; Gillespie, R Brent; Rodger, Matthew W M

    2015-01-01

    The increased access to books afforded to blind people via e-publishing has given them long-sought independence for both recreational and educational reading. In most cases, blind readers access materials using speech output. For some content such as highly technical texts, music, and graphics, speech is not an appropriate access modality as it does not promote deep understanding. Therefore blind braille readers often prefer electronic braille displays. But, these are prohibitively expensive. The search is on, therefore, for a low-cost refreshable display that would go beyond current technologies and deliver graphical content as well as text. And many solutions have been proposed, some of which reduce costs by restricting the number of characters that can be displayed, even down to a single braille cell. In this paper, we demonstrate that restricting tactile cues during braille reading leads to poorer performance in a letter recognition task. In particular, we show that lack of sliding contact between the fingertip and the braille reading surface results in more errors and that the number of errors increases as a function of presentation speed. These findings suggest that single cell displays which do not incorporate sliding contact are likely to be less effective for braille reading.

  6. Soya bean Gα proteins with distinct biochemical properties exhibit differential ability to complement Saccharomyces cerevisiae gpa1 mutant.

    Science.gov (United States)

    Roy Choudhury, Swarup; Wang, Yuqi; Pandey, Sona

    2014-07-01

    Signalling pathways mediated by heterotrimeric G-proteins are common to all eukaryotes. Plants have a limited number of each of the G-protein subunits, with the most elaborate G-protein network discovered so far in soya bean (Glycine max, also known as soybean) which has four Gα, four Gβ and ten Gγ proteins. Biochemical characterization of Gα proteins from plants suggests significant variation in their properties compared with the well-characterized non-plant proteins. Furthermore, the four soya bean Gα (GmGα) proteins exhibit distinct biochemical activities among themselves, but the extent to which such biochemical differences contribute to their in vivo function is also not known. We used the yeast gpa1 mutant which displays constitutive signalling and growth arrest in the pheromone-response pathway as an in vivo model to evaluate the effect of distinct biochemical activities of GmGα proteins. We showed that specific GmGα proteins can be activated during pheromone-dependent receptor-mediated signalling in yeast and they display different strengths towards complementation of yeast gpa1 phenotypes. We also identified amino acids that are responsible for differential complementation abilities of specific Gα proteins. These data establish that specific plant Gα proteins are functional in the receptor-mediated pheromone-response pathway in yeast and that the subtle biochemical differences in their activity are physiologically relevant.

  7. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  8. Software for graphic display systems

    International Nuclear Information System (INIS)

    Karlov, A.A.

    1978-01-01

    In this paper some aspects of graphic display systems are discussed. The design of a display subroutine library is described, with an example, and graphic dialogue software is considered primarily from the point of view of the programmer who uses a high-level language. (Auth.)

  9. Information Display: Considerations for Designing Modern Computer-Based Display Systems

    International Nuclear Information System (INIS)

    O'Hara, J.; Pirus, D.; Beltracchi, L.

    2003-01-01

    OAK- B135 To help nuclear utilities and suppliers design and implement plant information management systems and displays that provide accurate and timely information and require minimal navigation and interface management

  10. Refreshable Braille displays using EAP actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-04-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators.

  11. Refreshable Braille Displays Using EAP Actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-01-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators..

  12. System Would Generate Virtual Heads-Up Display

    Science.gov (United States)

    Lambert, James L.

    1994-01-01

    Proposed helmet-mounted electronic display system superimposes full-color alphanumerical and/or graphical information onto observer's visual field. Displayed information projected directly onto observer's retinas, giving observer illusion of full-size computer display in foreground or background. Display stereoscopic, holographic, or in form of virtual image. Used by pilots to view navigational information while looking outside or at instruments, by security officers to view information about critical facilities while looking at visitors, or possibly even stock-exchange facilities to view desktop monitors and overhead displays simultaneously. System includes acousto-optical tunable filter (AOTF), which acts as both spectral filter and spatial light modulator.

  13. Manufacturing considerations for AMLCD cockpit displays

    Science.gov (United States)

    Luo, Fang-Chen

    1995-06-01

    AMLCD cockpit displays need to meet more stringent requirements compared with AMLCD commercial displays in areas such as environmental conditions, optical performance and device reliability. Special considerations are required for the manufacturing of AMLCD cockpit displays in each process step to address these issues. Some examples are: UV stable polarizers, wide-temperature LC material, strong LC glue seal, ESS test system, gray scale voltage EEPROM, etc.

  14. Designing low cost LED display for the billboard

    Science.gov (United States)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  15. [Application of the grayscale standard display function to general purpose liquid-crystal display monitors for clinical use].

    Science.gov (United States)

    Tanaka, Nobukazu; Naka, Kentaro; Sueoka, Masaki; Higashida, Yoshiharu; Morishita, Junji

    2010-01-20

    Interpretations of medical images have been shifting to soft-copy readings with liquid-crystal display (LCD) monitors. The display function of the medical-grade LCD monitor for soft-copy readings is recommended to calibrate the grayscale standard display function (GSDF) in accordance with the guidelines of Japan and other countries. In this study, the luminance and display function of five models of eight general purpose LCD monitors were measured to gain an understanding of their characteristics. Moreover, the display function (gamma 2.2 or gamma 1.8) of general purpose LCD monitors was converted to GSDF through the use of a look-up table, and the detectability of a simulated lung nodule in the chest x-ray image was examined. As a result, the maximum luminance, contrast ratio, and luminance uniformity of general purpose LCD monitors, except for one model of two LCD monitors, met the management grade 1 standard in the guideline JESRA X-0093-2005. In addition, the detectability of simulated lung nodule in the mediastinal space was obviously improved by converting the display function of a general purpose LCD monitor into GSDF.

  16. Generating Animated Displays of Spacecraft Orbits

    Science.gov (United States)

    Candey, Robert M.; Chimiak, Reine A.; Harris, Bernard T.

    2005-01-01

    Tool for Interactive Plotting, Sonification, and 3D Orbit Display (TIPSOD) is a computer program for generating interactive, animated, four-dimensional (space and time) displays of spacecraft orbits. TIPSOD utilizes the programming interface of the Satellite Situation Center Web (SSCWeb) services to communicate with the SSC logic and database by use of the open protocols of the Internet. TIPSOD is implemented in Java 3D and effects an extension of the preexisting SSCWeb two-dimensional static graphical displays of orbits. Orbits can be displayed in any or all of the following seven reference systems: true-of-date (an inertial system), J2000 (another inertial system), geographic, geomagnetic, geocentric solar ecliptic, geocentric solar magnetospheric, and solar magnetic. In addition to orbits, TIPSOD computes and displays Sibeck's magnetopause and Fairfield's bow-shock surfaces. TIPSOD can be used by the scientific community as a means of projection or interpretation. It also has potential as an educational tool.

  17. IMDISP - INTERACTIVE IMAGE DISPLAY PROGRAM

    Science.gov (United States)

    Martin, M. D.

    1994-01-01

    The Interactive Image Display Program (IMDISP) is an interactive image display utility for the IBM Personal Computer (PC, XT and AT) and compatibles. Until recently, efforts to utilize small computer systems for display and analysis of scientific data have been hampered by the lack of sufficient data storage capacity to accomodate large image arrays. Most planetary images, for example, require nearly a megabyte of storage. The recent development of the "CDROM" (Compact Disk Read-Only Memory) storage technology makes possible the storage of up to 680 megabytes of data on a single 4.72-inch disk. IMDISP was developed for use with the CDROM storage system which is currently being evaluated by the Planetary Data System. The latest disks to be produced by the Planetary Data System are a set of three disks containing all of the images of Uranus acquired by the Voyager spacecraft. The images are in both compressed and uncompressed format. IMDISP can read the uncompressed images directly, but special software is provided to decompress the compressed images, which can not be processed directly. IMDISP can also display images stored on floppy or hard disks. A digital image is a picture converted to numerical form so that it can be stored and used in a computer. The image is divided into a matrix of small regions called picture elements, or pixels. The rows and columns of pixels are called "lines" and "samples", respectively. Each pixel has a numerical value, or DN (data number) value, quantifying the darkness or brightness of the image at that spot. In total, each pixel has an address (line number, sample number) and a DN value, which is all that the computer needs for processing. DISPLAY commands allow the IMDISP user to display all or part of an image at various positions on the display screen. The user may also zoom in and out from a point on the image defined by the cursor, and may pan around the image. To enable more or all of the original image to be displayed on the

  18. Oil defect detection of electrowetting display

    Science.gov (United States)

    Chiang, Hou-Chi; Tsai, Yu-Hsiang; Yan, Yung-Jhe; Huang, Ting-Wei; Mang, Ou-Yang

    2015-08-01

    In recent years, transparent display is an emerging topic in display technologies. Apply in many fields just like mobile device, shopping or advertising window, and etc. Electrowetting Display (EWD) is one kind of potential transparent display technology advantages of high transmittance, fast response time, high contrast and rich color with pigment based oil system. In mass production process of Electrowetting Display, oil defects should be found by Automated Optical Inspection (AOI) detection system. It is useful in determination of panel defects for quality control. According to the research of our group, we proposed a mechanism of AOI detection system detecting the different kinds of oil defects. This mechanism can detect different kinds of oil defect caused by oil overflow or material deteriorated after oil coating or driving. We had experiment our mechanism with a 6-inch Electrowetting Display panel from ITRI, using an Epson V750 scanner with 1200 dpi resolution. Two AOI algorithms were developed, which were high speed method and high precision method. In high precision method, oil jumping or non-recovered can be detected successfully. This mechanism of AOI detection system can be used to evaluate the oil uniformity in EWD panel process. In the future, our AOI detection system can be used in quality control of panel manufacturing for mass production.

  19. You Be the Judge: Display.

    Science.gov (United States)

    Koeninger, Jimmy G.

    The instructional package was developed to provide the distributive education teacher-coordinator with visual materials that can be used to supplement existing textbook offerings in the area of display (visual merchandising). Designed for use with 35mm slides of retail store displays, the package allows the student to view the slides of displays…

  20. Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Fujita, H.; Asai, Y.; Uemura, M.; Ookura, Y.; Matsumoto, M.; Johkoh, T.

    2005-01-01

    The aim of the present study was to propose suitable display functions for CT image representation on liquid crystal display (LCD) monitors by analyzing the characteristics of the monitor's typical display functions using psychophysical analysis. The luminance of the LCD monitor was adjusted to a maximum of 275 cd/m 2 and 480 cd/m 2 . Three types of postcalibrated display functions (i.e., GSDF, CIELAB, and Exponential γ 2.2) were evaluated. Luminance calculation of a new grayscale test pattern (NGTP) was done for the conversion of the digital driving level (DDL) into the CT value. The psychophysical gradient δ of display functions for the CT value was evaluated and compared via statistical analysis. The δ value of GSDF and CIE decreased exponentially; however, the δ value of Exponential γ 2.2 showed a convex curve with a peak at a specific point. There was a statistically significant difference among the δ values of the three types of display functions on the 480 cd/m 2 maximum via Kruskal Wallis test (P<0.001). The GSDF was suitable for observation of abdominal and lung CT images; however, the display function combined the Exponential γ 2.2 and the GSDF functions and was ideal for observation of brain CT images by psychophysical analysis. (orig.)

  1. Method for control-room display design

    International Nuclear Information System (INIS)

    Montmayeul, R.

    1988-01-01

    This document describes a method for control-room displays design. It can be used either for isolated display to add to an existing system either for the design of a full system of operator aids. The method is a top-down design with steps of possible iteration. The emphasis is put on display design rather than on system design; system aspects are just mentioned. Advantages of using a method are described [fr

  2. Statistical Arbitrage Mining for Display Advertising

    OpenAIRE

    Zhang, Weinan; Wang, Jun

    2015-01-01

    We study and formulate arbitrage in display advertising. Real-Time Bidding (RTB) mimics stock spot exchanges and utilises computers to algorithmically buy display ads per impression via a real-time auction. Despite the new automation, the ad markets are still informationally inefficient due to the heavily fragmented marketplaces. Two display impressions with similar or identical effectiveness (e.g., measured by conversion or click-through rates for a targeted audience) may sell for quite diff...

  3. Frequency of Gingival Display During Smiling and Comparison of Biometric Measurements in Subjects with and without Gingival Display

    International Nuclear Information System (INIS)

    Khan, F.; Abbas, M.

    2014-01-01

    Objective: To determine the frequency of gingival display during smiling and to compare biometric measurements in subjects with and without gingival display. Study Design: Cross-sectional study. Place and Duration of Study: Department of Prosthodontics, Dr. Ishrat-ul-Ibad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2012 to March 2013. Methodology: A total of 275 subjects (121 men and 154 women) were included in this study. The age of the participants ranged between 21 and 65 years. Measurements were carried out using digital caliper. For each participants, the gingival display was judged as either visible or not. The amounts of horizontal and vertical overlap of anterior teeth were measured using a digital caliper. Gender differences in these parameters and the relationship between subjects showing gingival display when smiling and the two intraoral dental biometric measurements were determined. Statistical analyses of data were performed using SPSS version 17.0 software. The mean scores for gender were calculated and a Student's t-test was used to identify significant differences between both groups. Significant level was set to 0.05. Results: A relatively small percentage of the subjects (37.8%) displayed gingiva when smiling. More women significantly displayed gingiva when smiling than men, with a 2:1 female: male ratio. Women had significantly (p=0.001) more horizontal overlap (3.34 +- 1.45 mm) than men (2.90 +- 1.44 mm), although no significant gender difference were found in vertical overlap. Subjects with gingival display had significantly (p < 0.05) more horizontal (3.49 +- 1.36 mm) and vertical (3.26 +- 1.47 mm) overlap of anterior teeth compared to those who did not display gingiva when smiling. Conclusion: Significantly more women displayed gingiva in smiling. Women had significantly more horizontal overlap than men. No gender differences were recorded between vertical overlap. Subjects who displayed

  4. Three-dimensional volumetric display by inclined-plane scanning

    Science.gov (United States)

    Miyazaki, Daisuke; Eto, Takuma; Nishimura, Yasuhiro; Matsushita, Kenji

    2003-05-01

    A volumetric display system based on three-dimensional (3-D) scanning that uses an inclined two-dimensional (2-D) image is described. In the volumetric display system a 2-D display unit is placed obliquely in an imaging system into which a rotating mirror is inserted. When the mirror is rotated, the inclined 2-D image is moved laterally. A locus of the moving image can be observed by persistence of vision as a result of the high-speed rotation of the mirror. Inclined cross-sectional images of an object are displayed on the display unit in accordance with the position of the image plane to observe a 3-D image of the object by persistence of vision. Three-dimensional images formed by this display system satisfy all the criteria for stereoscopic vision. We constructed the volumetric display systems using a galvanometer mirror and a vector-scan display unit. In addition, we constructed a real-time 3-D measurement system based on a light section method. Measured 3-D images can be reconstructed in the 3-D display system in real time.

  5. Displays: Entering a New Dimension

    Science.gov (United States)

    Starkman, Neal

    2007-01-01

    As display technologies prepare to welcome 3-D, the 21st-century classroom will soon bear little resemblance to anything students and teachers have ever seen. In this article, the author presents the latest innovations in the world of digital display technology. These include: (1) Touchlight, an interactive touch screen program that takes a normal…

  6. Crystal ball single event display

    International Nuclear Information System (INIS)

    Grosnick, D.; Gibson, A.; Allgower, C.; Alyea, J.; Argonne National Lab., IL

    1997-01-01

    The Single Event Display (SED) is a routine that is designed to provide information graphically about a triggered event within the Crystal Ball. The SED is written entirely in FORTRAN and uses the CERN-based HICZ graphing package. The primary display shows the amount of energy deposited in each of the NaI crystals on a Mercator-like projection of the crystals. Ten different shades and colors correspond to varying amounts of energy deposited within a crystal. Information about energy clusters is displayed on the crystal map by outlining in red the thirteen (or twelve) crystals contained within a cluster and assigning each cluster a number. Additional information about energy clusters is provided in a series of boxes containing useful data about the energy distribution among the crystals within the cluster. Other information shown on the event display include the event trigger type and data about π o 's and η's formed from pairs of clusters as found by the analyzer. A description of the major features is given, along with some information on how to install the SED into the analyzer

  7. Synthetic vision display evaluation studies

    Science.gov (United States)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  8. Touch sensitive electrorheological fluid based tactile display

    Science.gov (United States)

    Liu, Yanju; Davidson, Rob; Taylor, Paul

    2005-12-01

    A tactile display is programmable device whose controlled surface is intended to be investigated by human touch. It has a great number of potential applications in the field of virtual reality and elsewhere. In this research, a 5 × 5 tactile display array including electrorheological (ER) fluid has been developed and investigated. Force responses of the tactile display array have been measured while a probe was moved across the upper surface. The purpose of this was to simulate the action of touch performed by human finger. Experimental results show that the sensed surface information could be controlled effectively by adjusting the voltage activation pattern imposed on the tactels. The performance of the tactile display is durable and repeatable. The touch sensitivity of this ER fluid based tactile display array has also been investigated in this research. The results show that it is possible to sense the touching force normal to the display's surface by monitoring the change of current passing through the ER fluid. These encouraging results are helpful for constructing a new type of tactile display based on ER fluid which can act as both sensor and actuator at the same time.

  9. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  10. Flexible Bistable Cholesteric Reflective Displays

    Science.gov (United States)

    Yang, Deng-Ke

    2006-03-01

    Cholesteric liquid crystals (ChLCs) exhibit two stable states at zero field condition-the reflecting planar state and the nonreflecting focal conic state. ChLCs are an excellent candidate for inexpensive and rugged electronic books and papers. This paper will review the display cell structure,materials and drive schemes for flexible bistable cholesteric (Ch) reflective displays.

  11. Multimethods approach to safety-parameter-display evaluation

    International Nuclear Information System (INIS)

    Banks, W.W.; Blackman, H.S.; Gertman, D.I.; Petersen, R.J.

    1982-01-01

    The Human Factors Engineering Office of EG and G Idaho performed this NRC-funded study to assist the NRC in objectively assessing licensee-developed safety parameter display (SPD) formats and designs. The purpose of this study was to quantitatively measure the degree to which a tachistoscopic method of display evaluation would correlate with the results of a multidimensional rating approach to display evaluation. Results of the following three experiments will be presented; (a) tachistoscopic, (b) multidimensional rating scale, and (c) the combined results of a and b. The test material for all experiments consisted of three multivariate data display formats all under development as SPDs for reactor control rooms presenting safety parameter display data at the loss-of-fluid test (LOFT) facility. The three display formats studied were stars, deviation bar graphs, and meters. Eighteen adult volunteers were used as subjects. All were currently qualified reactor operators from the LOFT reactor plant, with a mean of 9.4 years reactor operating experience

  12. Antecedents and consequences of emotional display rule perceptions.

    Science.gov (United States)

    Diefendorff, James M; Richard, Erin M

    2003-04-01

    Central to all theories of emotional labor is the idea that individuals follow emotional display rules that specify the appropriate expression of emotions on the job. This investigation examined antecedents and consequences of emotional display rule perceptions. Full-time working adults (N = 152) from a variety of occupations provided self-report data, and supervisors and coworkers completed measures pertaining to the focal employees. Results using structural equation modeling revealed that job-based interpersonal requirements, supervisor display rule perceptions, and employee extraversion and neuroticism were predictive of employee display rule perceptions. Employee display rule perceptions, in turn, were related to self-reported job satisfaction and coworker ratings of employees' emotional displays on the job. Finally, neuroticism had direct negative relationships with job satisfaction and coworker ratings of employees' emotional displays.

  13. New portable FELIX 3D display

    Science.gov (United States)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  14. Digital Display Integration Project Project Online 2.0

    International Nuclear Information System (INIS)

    Bardsley, J. N.

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multiple sources or a composite image from a single source. The more rapid rate of technological improvements and the higher cost of flat panel displays raise the incentive for greater planning and guidance in the acquisition and integration of high performance displays into large organizations, such as LLNL. The goal of the Digital Display Integration Project (DDIP) is to provide such support. This will be achieved through collaboration with leading suppliers of displays, communications equipment and image-processing products, and by greater exchange of information within the Laboratory. The project will start in October 1999. During the first two years (FY2000-1), the primary focus of the program will be upon: introducing displays with high information content (over 5M pixels); facilitating the transition from analog to digital interfaces; enabling data transfer from key computer platforms; incorporating optical communications to remove length restrictions on data

  15. Evaluation of tactual displays for flight control

    Science.gov (United States)

    Levison, W. H.; Tanner, R. B.; Triggs, T. J.

    1973-01-01

    Manual tracking experiments were conducted to determine the suitability of tactual displays for presenting flight-control information in multitask situations. Although tracking error scores are considerably greater than scores obtained with a continuous visual display, preliminary results indicate that inter-task interference effects are substantially less with the tactual display in situations that impose high visual scanning workloads. The single-task performance degradation found with the tactual display appears to be a result of the coding scheme rather than the use of the tactual sensory mode per se. Analysis with the state-variable pilot/vehicle model shows that reliable predictions of tracking errors can be obtained for wide-band tracking systems once the pilot-related model parameters have been adjusted to reflect the pilot-display interaction.

  16. Real time speech formant analyzer and display

    Science.gov (United States)

    Holland, George E.; Struve, Walter S.; Homer, John F.

    1987-01-01

    A speech analyzer for interpretation of sound includes a sound input which converts the sound into a signal representing the sound. The signal is passed through a plurality of frequency pass filters to derive a plurality of frequency formants. These formants are converted to voltage signals by frequency-to-voltage converters and then are prepared for visual display in continuous real time. Parameters from the inputted sound are also derived and displayed. The display may then be interpreted by the user. The preferred embodiment includes a microprocessor which is interfaced with a television set for displaying of the sound formants. The microprocessor software enables the sound analyzer to present a variety of display modes for interpretive and therapeutic used by the user.

  17. Transparent 3D display for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Hong, Jisoo

    2012-11-01

    Two types of transparent three-dimensional display systems applicable for the augmented reality are demonstrated. One of them is a head-mounted-display-type implementation which utilizes the principle of the system adopting the concave floating lens to the virtual mode integral imaging. Such configuration has an advantage in that the threedimensional image can be displayed at sufficiently far distance resolving the accommodation conflict with the real world scene. Incorporating the convex half mirror, which shows a partial transparency, instead of the concave floating lens, makes it possible to implement the transparent three-dimensional display system. The other type is the projection-type implementation, which is more appropriate for the general use than the head-mounted-display-type implementation. Its imaging principle is based on the well-known reflection-type integral imaging. We realize the feature of transparent display by imposing the partial transparency to the array of concave mirror which is used for the screen of reflection-type integral imaging. Two types of configurations, relying on incoherent and coherent light sources, are both possible. For the incoherent configuration, we introduce the concave half mirror array, whereas the coherent one adopts the holographic optical element which replicates the functionality of the lenslet array. Though the projection-type implementation is beneficial than the head-mounted-display in principle, the present status of the technical advance of the spatial light modulator still does not provide the satisfactory visual quality of the displayed three-dimensional image. Hence we expect that the head-mounted-display-type and projection-type implementations will come up in the market in sequence.

  18. New developments in flexible cholesteric liquid crystal displays

    Science.gov (United States)

    Schneider, Tod; Davis, Donald J.; Franklin, Sean; Venkataraman, Nithya; McDaniel, Diaz; Nicholson, Forrest; Montbach, Erica; Khan, Asad; Doane, J. William

    2007-02-01

    Flexible Cholesteric liquid crystal displays have been rapidly maturing into a strong contender in the flexible display market. Encapsulation of the Cholesteric liquid crystal permits the use of flexible plastic substrates and roll-to-roll production. Recent advances include ultra-thin displays, laser-cut segmented displays of variable geometry, and smart card applications. Exciting technologies such as simultaneous laser-edge sealing and singulation enable high volume production, excellent quality control and non-traditional display geometries and formats.

  19. 27 CFR 6.35 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.35 Section 6.35 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Renting display space. The renting of display space by an industry member at a retail establishment...

  20. 27 CFR 6.56 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.56 Section 6.56 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Distribution Service § 6.56 Renting display space. A promotion whereby an industry member rents display space...

  1. 14 CFR 255.4 - Display of information.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS AIRLINE COMPUTER RESERVATIONS SYSTEMS § 255.4 Display of information. (a) All systems shall provide at least one integrated display that includes the schedules, fares, rules, and availability of all... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Display of information. 255.4 Section 255.4...

  2. PMS2 endonuclease activity has distinct biological functions and is essential for genome maintenance.

    Science.gov (United States)

    van Oers, Johanna M M; Roa, Sergio; Werling, Uwe; Liu, Yiyong; Genschel, Jochen; Hou, Harry; Sellers, Rani S; Modrich, Paul; Scharff, Matthew D; Edelmann, Winfried

    2010-07-27

    The DNA mismatch repair protein PMS2 was recently found to encode a novel endonuclease activity. To determine the biological functions of this activity in mammals, we generated endonuclease-deficient Pms2E702K knock-in mice. Pms2EK/EK mice displayed increased genomic mutation rates and a strong cancer predisposition. In addition, class switch recombination, but not somatic hypermutation, was impaired in Pms2EK/EK B cells, indicating a specific role in Ig diversity. In contrast to Pms2-/- mice, Pms2EK/EK male mice were fertile, indicating that this activity is dispensable in spermatogenesis. Therefore, the PMS2 endonuclease activity has distinct biological functions and is essential for genome maintenance and tumor suppression.

  3. Projection display industry market and technology trends

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1995-04-01

    The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.

  4. Brief history of electronic stereoscopic displays

    Science.gov (United States)

    Lipton, Lenny

    2012-02-01

    A brief history of recent developments in electronic stereoscopic displays is given concentrating on products that have succeeded in the market place and hence have had a significant influence on future implementations. The concentration is on plano-stereoscopic (two-view) technology because it is now the dominant display modality in the marketplace. Stereoscopic displays were created for the motion picture industry a century ago, and this technology influenced the development of products for science and industry, which in turn influenced product development for entertainment.

  5. Advanced and tendencies in the development of display technologies

    Science.gov (United States)

    Kompanets, I. N.

    2006-06-01

    Advances and key display applications are discussed. Computer, compact mobile, TV and collective large screen displays are mentioned. Flat panel displays step on CRT devices to leave them behind in 2007. Materials, active matricies and applications of bright radiative field emission and organic LED displays are developing successively and pressing other technologies to be used in photo-cameras, cellular phones, auto-cars and avionics. Progress in flexible screens can substantially extend the display design and application soon. 3D display systems are under intensive development, and laser is an important unit in some vaiants of holographic and volumetric 3D displays. Value forecast of different display markets is presented.

  6. Color Analysis in Air Traffic Control Displays, Part II. Auxiliary Displays

    National Research Council Canada - National Science Library

    Xing, Jing

    2007-01-01

    ...), Traffic Management Advisor (TMA), and Integrated Terminal Weather System (ITWS). For each display, we documented the background and default colors, color-coding, color usage, associated purposes of color use, and color complexity...

  7. Visual Merchandising through Display: Advertising Services Occupations.

    Science.gov (United States)

    Maurer, Nelson S.

    The increasing use of displays by businessmen is creating a demand for display workers. This demand may be met by preparing high school students to enter the field of display. Additional workers might be recruited by offering adult training programs for individuals working within the stores. For this purpose a curriculum guide has been developed…

  8. 14 CFR 125.7 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.7 Display of certificate. (a) The certificate holder must display a true copy of the certificate in each of its aircraft. (b... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 125.7 Section 125.7...

  9. [Peptide phage display in biotechnology and biomedicine].

    Science.gov (United States)

    Kuzmicheva, G A; Belyavskaya, V A

    2016-07-01

    To date peptide phage display is one of the most common combinatorial methods used for identifying specific peptide ligands. Phage display peptide libraries containing billions different clones successfully used for selection of ligands with high affinity and selectivity toward wide range of targets including individual proteins, bacteria, viruses, spores, different kind of cancer cells and variety of nonorganic targets (metals, alloys, semiconductors etc.) Success of using filamentous phage in phage display technologies relays on the robustness of phage particles and a possibility to genetically modify its DNA to construct new phage variants with novel properties. In this review we are discussing characteristics of the most known non-commercial peptide phage display libraries of different formats (landscape libraries in particular) and their successful applications in several fields of biotechnology and biomedicine: discovery of peptides with diagnostic values against different pathogens, discovery and using of peptides recognizing cancer cells, trends in using of phage display technologies in human interactome studies, application of phage display technologies in construction of novel nano materials.

  10. Industrial Personal Computer based Display for Nuclear Safety System

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min

    2014-01-01

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view

  11. Industrial Personal Computer based Display for Nuclear Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min [KEPCO, Youngin (Korea, Republic of)

    2014-08-15

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view.

  12. Viewpoint adaptive display of HDR images

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Mantel, Claire

    2017-01-01

    In this paper viewpoint adaptive display of HDR images incorporating the effects of ambient light is presented and evaluated. LED backlight displays may render HDR images, but while at a global scale a high dynamic range may be achieved, locally the contrast is limited by the leakage of light...... through the LC elements of the display. To render high quality images, the display with backlight dimming can compute the values of the LED backlight and LC elements based on the input image, information about the viewpoint of the observer(s) and information of the ambient light. The goal is to achieve...... the best perceptual reproduction of the specified target image derived from the HDR input image in the specific viewing situation including multiple viewers, possibly having different preferences. An optimization based approach is presented. Some tests with reproduced images are also evaluated subjectively...

  13. Display Sharing: An Alternative Paradigm

    Science.gov (United States)

    Brown, Michael A.

    2010-01-01

    The current Johnson Space Center (JSC) Mission Control Center (MCC) Video Transport System (VTS) provides flight controllers and management the ability to meld raw video from various sources with telemetry to improve situational awareness. However, maintaining a separate infrastructure for video delivery and integration of video content with data adds significant complexity and cost to the system. When considering alternative architectures for a VTS, the current system's ability to share specific computer displays in their entirety to other locations, such as large projector systems, flight control rooms, and back supporting rooms throughout the facilities and centers must be incorporated into any new architecture. Internet Protocol (IP)-based systems also support video delivery and integration. IP-based systems generally have an advantage in terms of cost and maintainability. Although IP-based systems are versatile, the task of sharing a computer display from one workstation to another can be time consuming for an end-user and inconvenient to administer at a system level. The objective of this paper is to present a prototype display sharing enterprise solution. Display sharing is a system which delivers image sharing across the LAN while simultaneously managing bandwidth, supporting encryption, enabling recovery and resynchronization following a loss of signal, and, minimizing latency. Additional critical elements will include image scaling support, multi -sharing, ease of initial integration and configuration, integration with desktop window managers, collaboration tools, host and recipient controls. This goal of this paper is to summarize the various elements of an IP-based display sharing system that can be used in today's control center environment.

  14. Development and validation of a measure of display rule knowledge: the display rule assessment inventory.

    Science.gov (United States)

    Matsumoto, David; Yoo, Seung Hee; Hirayama, Satoko; Petrova, Galina

    2005-03-01

    As one component of emotion regulation, display rules, which reflect the regulation of expressive behavior, have been the topic of many studies. Despite their theoretical and empirical importance, however, to date there is no measure of display rules that assesses a full range of behavioral responses that are theoretically possible when emotion is elicited. This article reports the development of a new measure of display rules that surveys 5 expressive modes: expression, deamplification, amplification, qualification, and masking. Two studies provide evidence for its internal and temporal reliability and for its content, convergent, discriminant, external, and concurrent predictive validity. Additionally, Study 1, involving American, Russian, and Japanese participants, demonstrated predictable cultural differences on each of the expressive modes. Copyright 2005 APA, all rights reserved.

  15. Precisely Molded Nanoparticle Displaying DENV-E Proteins Induces Robust Serotype-Specific Neutralizing Antibody Responses.

    Directory of Open Access Journals (Sweden)

    Stefan W Metz

    2016-10-01

    Full Text Available Dengue virus (DENV is the causative agent of dengue fever and dengue hemorrhagic fever. The virus is endemic in over 120 countries, causing over 350 million infections per year. Dengue vaccine development is challenging because of the need to induce simultaneous protection against four antigenically distinct DENV serotypes and evidence that, under some conditions, vaccination can enhance disease due to specific immunity to the virus. While several live-attenuated tetravalent dengue virus vaccines display partial efficacy, it has been challenging to induce balanced protective immunity to all 4 serotypes. Instead of using whole-virus formulations, we are exploring the potentials for a particulate subunit vaccine, based on DENV E-protein displayed on nanoparticles that have been precisely molded using Particle Replication in Non-wetting Template (PRINT technology. Here we describe immunization studies with a DENV2-nanoparticle vaccine candidate. The ectodomain of DENV2-E protein was expressed as a secreted recombinant protein (sRecE, purified and adsorbed to poly (lactic-co-glycolic acid (PLGA nanoparticles of different sizes and shape. We show that PRINT nanoparticle adsorbed sRecE without any adjuvant induces higher IgG titers and a more potent DENV2-specific neutralizing antibody response compared to the soluble sRecE protein alone. Antigen trafficking indicate that PRINT nanoparticle display of sRecE prolongs the bio-availability of the antigen in the draining lymph nodes by creating an antigen depot. Our results demonstrate that PRINT nanoparticles are a promising platform for delivering subunit vaccines against flaviviruses such as dengue and Zika.

  16. The signer and the sign: cortical correlates of person identity and language processing from point-light displays.

    Science.gov (United States)

    Campbell, Ruth; Capek, Cheryl M; Gazarian, Karine; MacSweeney, Mairéad; Woll, Bencie; David, Anthony S; McGuire, Philip K; Brammer, Michael J

    2011-09-01

    In this study, the first to explore the cortical correlates of signed language (SL) processing under point-light display conditions, the observer identified either a signer or a lexical sign from a display in which different signers were seen producing a number of different individual signs. Many of the regions activated by point-light under these conditions replicated those previously reported for full-image displays, including regions within the inferior temporal cortex that are specialised for face and body-part identification, although such body parts were invisible in the display. Right frontal regions were also recruited - a pattern not usually seen in full-image SL processing. This activation may reflect the recruitment of information about person identity from the reduced display. A direct comparison of identify-signer and identify-sign conditions showed these tasks relied to a different extent on the posterior inferior regions. Signer identification elicited greater activation than sign identification in (bilateral) inferior temporal gyri (BA 37/19), fusiform gyri (BA 37), middle and posterior portions of the middle temporal gyri (BAs 37 and 19), and superior temporal gyri (BA 22 and 42). Right inferior frontal cortex was a further focus of differential activation (signer>sign). These findings suggest that the neural systems supporting point-light displays for the processing of SL rely on a cortical network including areas of the inferior temporal cortex specialized for face and body identification. While this might be predicted from other studies of whole body point-light actions (Vaina, Solomon, Chowdhury, Sinha, & Belliveau, 2001) it is not predicted from the perspective of spoken language processing, where voice characteristics and speech content recruit distinct cortical regions (Stevens, 2004) in addition to a common network. In this respect, our findings contrast with studies of voice/speech recognition (Von Kriegstein, Kleinschmidt, Sterzer

  17. Display analysis with the optimal control model of the human operator. [pilot-vehicle display interface and information processing

    Science.gov (United States)

    Baron, S.; Levison, W. H.

    1977-01-01

    Application of the optimal control model of the human operator to problems in display analysis is discussed. Those aspects of the model pertaining to the operator-display interface and to operator information processing are reviewed and discussed. The techniques are then applied to the analysis of advanced display/control systems for a Terminal Configured Vehicle. Model results are compared with those obtained in a large, fixed-base simulation.

  18. Solar active region display system

    Science.gov (United States)

    Golightly, M.; Raben, V.; Weyland, M.

    2003-04-01

    The Solar Active Region Display System (SARDS) is a client-server application that automatically collects a wide range of solar data and displays it in a format easy for users to assimilate and interpret. Users can rapidly identify active regions of interest or concern from color-coded indicators that visually summarize each region's size, magnetic configuration, recent growth history, and recent flare and CME production. The active region information can be overlaid onto solar maps, multiple solar images, and solar difference images in orthographic, Mercator or cylindrical equidistant projections. Near real-time graphs display the GOES soft and hard x-ray flux, flare events, and daily F10.7 value as a function of time; color-coded indicators show current trends in soft x-ray flux, flare temperature, daily F10.7 flux, and x-ray flare occurrence. Through a separate window up to 4 real-time or static graphs can simultaneously display values of KP, AP, daily F10.7 flux, GOES soft and hard x-ray flux, GOES >10 and >100 MeV proton flux, and Thule neutron monitor count rate. Climatologic displays use color-valued cells to show F10.7 and AP values as a function of Carrington/Bartel's rotation sequences - this format allows users to detect recurrent patterns in solar and geomagnetic activity as well as variations in activity levels over multiple solar cycles. Users can customize many of the display and graph features; all displays can be printed or copied to the system's clipboard for "pasting" into other applications. The system obtains and stores space weather data and images from sources such as the NOAA Space Environment Center, NOAA National Geophysical Data Center, the joint ESA/NASA SOHO spacecraft, and the Kitt Peak National Solar Observatory, and can be extended to include other data series and image sources. Data and images retrieved from the system's database are converted to XML and transported from a central server using HTTP and SOAP protocols, allowing

  19. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  20. Developing an integrated digitizing and display surface

    Science.gov (United States)

    Hipple, James D.; Wedding, Daniel K.; Wedding, Donald K., Sr.

    1995-04-01

    The development of an integrated digitizing and display surface, which utilizes touch entry and flat panel display (FPD) technology, is a significant hardware advance in the field of geographic information systems (GIS). Inherent qualities of the FPD, notably the ac gas plasma display, makes such a marriage inevitable. Large diagonal sizes, high resolution color, screen flatness, and monitor thickness are desirable features of an integrated digitizing and display surface. Recently, the GIS literature has addressed a need for such an innovation. The development of graphics displays based on sophisticated technologies include `photorealistic' (or high definition) imaging at resolutions of 2048 X 2048 or greater, palates of 16.7 million colors, formats greater than 30 inches diagonal, and integrated touch entry. In this paper, there is an evaluation of FPDs and data input technologies in the development of such a product.

  1. Helmet-mounted display requirements: just another head-up display (HUD) or a different animal altogether?

    Science.gov (United States)

    Newman, Richard L.; Haworth, Loran A.

    1994-06-01

    The helmet-mounted display (HMD) presents flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. The present study reviewed the state-of-the-art in HMDs and identified a number of issues applying to HMDs. Several are identical to head-up display (HUD) issues: symbol standardization, excessive clutter, and the need for integration with other cockpit displays and controls. Other issues are unique to the head-mounted display: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and field-of-view (FOV) vs. resolution tradeoff requirements. Symbol stabilization is critical. In the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and nap-of-the-earth (NOE) flight. This high workload translates into excessive training requirements. At the same time, misleading symbology makes interpretation of the height of obstructions impossible. The underlying cause is the absence of design criteria for HMDs. The existing military standard does not reflect the current state of technology. In addition, there are inadequate test and evaluation guidelines. The situation parallels the situation for HUDs several years ago.

  2. Digital Display Integration Project Project Online 2.0

    CERN Document Server

    Bardsley, J N

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multip...

  3. Autostereoscopic display technology for mobile 3DTV applications

    Science.gov (United States)

    Harrold, Jonathan; Woodgate, Graham J.

    2007-02-01

    Mobile TV is now a commercial reality, and an opportunity exists for the first mass market 3DTV products based on cell phone platforms with switchable 2D/3D autostereoscopic displays. Compared to conventional cell phones, TV phones need to operate for extended periods of time with the display running at full brightness, so the efficiency of the 3D optical system is key. The desire for increased viewing freedom to provide greater viewing comfort can be met by increasing the number of views presented. A four view lenticular display will have a brightness five times greater than the equivalent parallax barrier display. Therefore, lenticular displays are very strong candidates for cell phone 3DTV. Selection of Polarisation Activated Microlens TM architectures for LCD, OLED and reflective display applications is described. The technology delivers significant advantages especially for high pixel density panels and optimises device ruggedness while maintaining display brightness. A significant manufacturing breakthrough is described, enabling switchable microlenses to be fabricated using a simple coating process, which is also readily scalable to large TV panels. The 3D image performance of candidate 3DTV panels will also be compared using autostereoscopic display optical output simulations.

  4. Excitations Partition into Two Distinct Populations in Bulk Perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lili [Department of Chemistry, The James Franck Institute, The Institute for Biophysical Dynamics, The University of Chicago, Chicago IL 60637 USA; Brawand, Nicholas P. [The Institute for Molecular Engineering, The University of Chicago, Chicago IL 60637 USA; Vörös, Márton [Materials Science Division, Argonne National Laboratory, Lemont IL 60439 USA; Dahlberg, Peter D. [Department of Chemistry, The James Franck Institute, The Institute for Biophysical Dynamics, The University of Chicago, Chicago IL 60637 USA; Chemical Sciences and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Otto, John P. [Department of Chemistry, The James Franck Institute, The Institute for Biophysical Dynamics, The University of Chicago, Chicago IL 60637 USA; Williams, Nicholas E. [Department of Chemistry, The James Franck Institute, The Institute for Biophysical Dynamics, The University of Chicago, Chicago IL 60637 USA; Tiede, David M. [Chemical Sciences and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Galli, Giulia [The Institute for Molecular Engineering, The University of Chicago, Chicago IL 60637 USA; Materials Science Division, Argonne National Laboratory, Lemont IL 60439 USA; Engel, Gregory S. [Department of Chemistry, The James Franck Institute, The Institute for Biophysical Dynamics, The University of Chicago, Chicago IL 60637 USA

    2018-01-09

    Organolead halide perovskites convert optical excitations to charge carriers with remarkable efficiency in optoelectronic devices. Previous research predominantly documents dynamics in perovskite thin films; however, extensive disorder in this platform may obscure the observed carrier dynamics. Here, carrier dynamics in perovskite single-domain single crystals is examined by performing transient absorption spectroscopy in a transmissive geometry. Two distinct sets of carrier populations that coexist at the same radiation fluence, but display different decay dynamics, are observed: one dominated by second-order recombination and the other by third-order recombination. Based on ab initio simulations, this observation is found to be most consistent with the hypothesis that free carriers and localized carriers coexist due to polaron formation. The calculations suggest that polarons will form in both CH3NH3PbBr3 and CH3NH3PbI3 crystals, but that they are more pronounced in CH3NH3PbBr3. Single-crystal CH3NH3PbBr3 could represent the key to understanding the impact of polarons on the transport properties of perovskite optoelectronic devices.

  5. Advanced image display systems in radiology

    International Nuclear Information System (INIS)

    Wendler, T.

    1987-01-01

    Advanced image display systems for the fully digital diagnostic imaging departments of the future will be far more than simple replacements of the traditional film-viewing equipment. The new capabilities of very high resolution and highly dynamic displays offer a userfriendly and problem-oriented way of image interpretation. Advanced harware-, software- and human-machine interaction-concepts have been outlined. A scenario for a future way of handling and displaying images, reflecting a new image viewing paradigm in radiology is sketched which has been realized in an experimental image workstation model in the laboratory which, despite its technical complexity, offers a consistent strategy for fast and convenient interaction with image objects. The perspective of knowledge based techniques for workstation control software with object-oriented programming environments and user- and task-adaptive behavior leads to more advanced display properties and a new quality of userfriendliness. 2 refs.; 5 figs

  6. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  7. Distinctive Citizenship

    DEFF Research Database (Denmark)

    Kaur, Ravinder

    2009-01-01

    The refugee, in India's Partition history, appears as an enigmatic construct - part pitiful, part heroic, though mostly shorn of agency - representing the surface of the human tragedy of Partition. Yet this archetype masks the undercurrent of social distinctions that produced hierarchies of post...

  8. Three-dimensional display improves observer speed and accuracy

    International Nuclear Information System (INIS)

    Nelson, J.A.; Rowberg, A.H.; Kuyper, S.; Choi, H.S.

    1989-01-01

    In an effort to evaluate the potential cost-effectiveness of three-dimensional (3D) display equipment, we compared the speed and accuracy of experienced radiologists identifying in sliced uppercase letters from CT scans with 2D and pseudo-3D display. CT scans of six capital letters were obtained and printed as a 2D display or as a synthesized pseudo-3D display (Pixar). Six observes performed a timed identification task. Radiologists read the 3D display an average of 16 times faster than the 2D, and the average error rate of 2/6 (± 0.6/6) for 2D interpretations was totally eliminated. This degree of improvement in speed and accuracy suggests that the expense of 3D display may be cost-effective in a defined clinical setting

  9. To 'display' or not to 'display'- that is the peptide

    CSIR Research Space (South Africa)

    Crampton, Michael C

    2008-11-01

    Full Text Available eukaryotic and prokaryotic systems but has mainly focused around phages (Etz et al, 2001), yeast (Kondo and Ueda, 2004) and bacteria (Lee et al 2003). The central variable domain of the FliC protein is dispensable and can be used for the insertion and display...

  10. Functional displays

    International Nuclear Information System (INIS)

    Angelis De, F.; Haentjens, J.

    1995-01-01

    The Functional Displays are directly derived from the Man-Machine Design key document: Function-Based Task Analysis. The presentation defines and describes the goals-means structure of the plant function along with applicable control volumes and parameters of interest. The purpose of the subject is to show, through an example of a preliminary design, what the main parts of a function are. (3 figs.)

  11. Display hardware

    International Nuclear Information System (INIS)

    Myers, D.R.

    1983-01-01

    To appreciate the limitations and possibilities of computer graphics it is necessary to have some acquaintance with the available technology. The aim of this chapter is to mention briefly the different display types and their 'ball-park' price ranges. It must be stressed that prices change rapidly, and so those quoted here are only intended to give an idea of the cost at the time of writing.

  12. A visual-display and storage device

    Science.gov (United States)

    Bosomworth, D. R.; Moles, W. H.

    1972-01-01

    Memory and display device uses cathodochromic material to store visual information and fast phosphor to recall information for display and electronic processing. Cathodochromic material changes color when bombarded with electrons, and is restored to its original color when exposed to light of appropiate wavelength.

  13. NCAP projection displays: key issues for commercialization

    Science.gov (United States)

    Tomita, Akira; Jones, Philip J.

    1992-06-01

    Recently there has been much interest in a new polymer nematic dispersion technology, often called as NCAP, PDLC, PNLC, LCPC, etc., since projection displays using this technology have been shown to produce much brighter display images than projectors using conventional twisted nematic (TN) lightvalves. For commercializing projection displays based on this polymer nematic dispersion technology, the new materials must not only meet various electro- optic requirements, e.g., operational voltage, `off-state'' scattering angle, voltage holding ratio and hysteresis, but must also be stable over the lifetime of the product. This paper reports recent progress in the development of NCAP based projection displays and discusses some of the key commercialization issues.

  14. Polyvalent Display of Biomolecules on Live Cells.

    Science.gov (United States)

    Shi, Peng; Zhao, Nan; Lai, Jinping; Coyne, James; Gaddes, Erin R; Wang, Yong

    2018-06-04

    Surface display of biomolecules on live cells offers new opportunities to treat human diseases and perform basic studies. Existing methods are primarily focused on monovalent functionalization, that is, the display of single biomolecules across the cell surface. Here we show that the surface of live cells can be functionalized to display polyvalent biomolecular structures through two-step reactions under physiological conditions. This polyvalent functionalization enables the cell surface to recognize the microenvironment one order of magnitude more effectively than with monovalent functionalization. Thus, polyvalent display of biomolecules on live cells holds great potential for various biological and biomedical applications. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. PENGARUH DISPLAY PRODUK PADA KEPUTUSAN PEMBELIAN KONSUMEN

    Directory of Open Access Journals (Sweden)

    Ina Melati

    2012-11-01

    Full Text Available Most of ritel outlet recently using product display as a one of their best marketing strategy, the reason is quiet easy to be understood, since consumers are too easy to be teased by those kind of beautiful product display that is being displayed by the retail outlet. The good retail outlets are trying their best to design and make the very good product display, so they can attract more consumers and make them not thinking twice to visit their store and purchase lots of thing. Clearly seeing that an attractive product design is able to influence a consumer to make a buying decision. 

  16. Natural display mode for digital DICOM-conformant diagnostic imaging.

    Science.gov (United States)

    Peters, Klaus-Ruediger; Ramsby, Gale R

    2002-09-01

    The authors performed this study to investigate the verification of the contrast display properties defined by the digital imaging and communication in medicine (DICOM) PS (picture archiving and communication system [PACS] standard) 3.14-2001 gray-scale display function standard and their dependency on display luminance range and video signal bandwidth. Contrast sensitivity and contrast linearity of DICOM-conformant displays were measured in just-noticeable differences (JNDs) on special perceptual contrast test patterns. Measurements were obtained six times at various display settings under dark room conditions. Display luminance range and video bandwidth had a significant effect on contrast perception. The perceptual promises of the standard could be established only with displays that were calibrated to a unity contrast resolution, at which the number of displayed intensity steps was equal to the number of perceivable contrast steps (JNDs). Such display conditions provide for visual perception information at the level of single-step contrast sensitivity and full-range contrast linearity. These "natural display" conditions also help minimize the Mach banding effects that otherwise reduce contrast sensitivity and contrast linearity. Most, if not all, conventionally used digital display modalities are driven with a contrast resolution larger than 1. Such conditions reduce contrast perception when compared with natural imaging conditions. The DICOM-conformant display conditions at unity contrast resolution were characterized as the "natural display" mode, and, thus, the authors a priori recommend them as being useful for making a primary diagnosis with PACS and teleradiology and as a standard for psychophysical research and performance measurements.

  17. Pilot stereotypes for navigation symbols on electronic displays

    Science.gov (United States)

    2006-09-20

    There is currently no common symbology standard for the : electronic display of navigation information. The wide : range of display technologies and the different functions : these displays support make it difficult to design symbols : that are easil...

  18. Evaluating Ambient Displays in the Wild

    DEFF Research Database (Denmark)

    Messeter, Jörn; Molenaar, Daryn

    A prominent issue for evaluating ambient displays has been the conflict between the relative intrusiveness of evaluation methods and the intention to keep the display at the periphery of the user’s attention. There is a general lack of research discussing the difficulties of evaluating ambient di...

  19. Panoramic, large-screen, 3-D flight display system design

    Science.gov (United States)

    Franklin, Henry; Larson, Brent; Johnson, Michael; Droessler, Justin; Reinhart, William F.

    1995-01-01

    The report documents and summarizes the results of the required evaluations specified in the SOW and the design specifications for the selected display system hardware. Also included are the proposed development plan and schedule as well as the estimated rough order of magnitude (ROM) cost to design, fabricate, and demonstrate a flyable prototype research flight display system. The thrust of the effort was development of a complete understanding of the user/system requirements for a panoramic, collimated, 3-D flyable avionic display system and the translation of the requirements into an acceptable system design for fabrication and demonstration of a prototype display in the early 1997 time frame. Eleven display system design concepts were presented to NASA LaRC during the program, one of which was down-selected to a preferred display system concept. A set of preliminary display requirements was formulated. The state of the art in image source technology, 3-D methods, collimation methods, and interaction methods for a panoramic, 3-D flight display system were reviewed in depth and evaluated. Display technology improvements and risk reductions associated with maturity of the technologies for the preferred display system design concept were identified.

  20. White constancy method for mobile displays

    Science.gov (United States)

    Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo

    2014-03-01

    In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.

  1. Safety parameter display systems' effect on operator performance

    International Nuclear Information System (INIS)

    Cerven, F.; Ford, R.E.; Blackman, H.S.

    1983-01-01

    Computer generated displays are a powerful and flexible tool for presenting data to the operators of nuclear power plants. Such displays are currently being developed in industry for use as safety parameter displays and for use in advanced control rooms. There exists a need for methods to objectively evaluate the effect of these displays, positive or negative, on the performance of control room personnel. Results of developing one such method, noninteractive simulation, and the two experiments that were performed to determine if it can be used as a method for evaluating computer displays are presented. This method is more objective and powerful than pencil and paper methods because it measures human performance rather than opinion or perference, has excellent control of the experimental variables, and has a higher fidelity to the control room environment. The results of these experiments indicates that the present methodology does not differentiate among the display types tested at a statistically significant level. In other words, all display types tested worked equally well in providing operators needed information

  2. Investigating pointing tasks across angularly coupled display areas

    DEFF Research Database (Denmark)

    Hennecke, Fabian; De Luca, Alexander; Nguyen, Ngo Dieu Huong

    2013-01-01

    Pointing tasks are a crucial part of today’s graphical user interfaces. They are well understood for flat displays and most prominently are modeled through Fitts’ Law. For novel displays (e.g., curved displays with multi-purpose areas), however, it remains unclear whether such models for predicting...... that the target position affects overall pointing speed and offset in both conditions. However, we also found that Fitts’ Law can in fact still be used to predict performance as on flat displays. Our results help designers to optimize user interfaces on angularly coupled displays when pointing tasks are involved....... user performance still hold – in particular when pointing is performed across differently oriented areas. To answer this question, we conducted an experiment on an angularly coupled display – the Curve – with two input conditions: direct touch and indirect mouse pointer. Our findings show...

  3. User interface design in safety parameter display systems

    International Nuclear Information System (INIS)

    Schultz, E.E. Jr.; Johnson, G.L.

    1988-01-01

    The extensive installation of computerized safety Parameter Display Systems (SPDSs) in nuclear power plants since the Three-Mile Island accident has enhanced plant safety. It has also raised new issues of how best to ensure an effective interface between human operators and the plant via computer systems. New developments in interface technologies since the current generation of SPDSs was installed can contribute to improving display interfaces. These technologies include new input devices, three-dimensional displays, delay indicators, and auditory displays. Examples of how they might be applied to improve current SPDSs are given. These examples illustrate how the new use interface technology could be applied to future nuclear plant displays

  4. Position display device

    International Nuclear Information System (INIS)

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  5. Ocular Tolerance of Contemporary Electronic Display Devices.

    Science.gov (United States)

    Clark, Andrew J; Yang, Paul; Khaderi, Khizer R; Moshfeghi, Andrew A

    2018-05-01

    Electronic displays have become an integral part of life in the developed world since the revolution of mobile computing a decade ago. With the release of multiple consumer-grade virtual reality (VR) and augmented reality (AR) products in the past 2 years utilizing head-mounted displays (HMDs), as well as the development of low-cost, smartphone-based HMDs, the ability to intimately interact with electronic screens is greater than ever. VR/AR HMDs also place the display at much closer ocular proximity than traditional electronic devices while also isolating the user from the ambient environment to create a "closed" system between the user's eyes and the display. Whether the increased interaction with these devices places the user's retina at higher risk of damage is currently unclear. Herein, the authors review the discovery of photochemical damage of the retina from visible light as well as summarize relevant clinical and preclinical data regarding the influence of modern display devices on retinal health. Multiple preclinical studies have been performed with modern light-emitting diode technology demonstrating damage to the retina at modest exposure levels, particularly from blue-light wavelengths. Unfortunately, high-quality in-human studies are lacking, and the small clinical investigations performed to date have failed to keep pace with the rapid evolutions in display technology. Clinical investigations assessing the effect of HMDs on human retinal function are also yet to be performed. From the available data, modern consumer electronic displays do not appear to pose any acute risk to vision with average use; however, future studies with well-defined clinical outcomes and illuminance metrics are needed to better understand the long-term risks of cumulative exposure to electronic displays in general and with "closed" VR/AR HMDs in particular. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:346-354.]. Copyright 2018, SLACK Incorporated.

  6. 27 CFR 6.55 - Display service.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Display service. 6.55 Section 6.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Paying for Advertising, Display Or...

  7. Differentiation of closely related but biologically distinct cherry isolates of Prunus necrotic ringspot virus by polymerase chain reaction.

    Science.gov (United States)

    Hammond, R W; Crosslin, J M; Pasini, R; Howell, W E; Mink, G I

    1999-07-01

    Prunus necrotic ringspot ilarvirus (PNRSV) exists as a number of biologically distinct variants which differ in host specificity, serology, and pathology. Previous nucleotide sequence alignment and phylogenetic analysis of cloned reverse transcription-polymerase chain reaction (RT-PCR) products of several biologically distinct sweet cherry isolates revealed correlations between symptom type and the nucleotide and amino acid sequences of the 3a (putative movement protein) and 3b (coat protein) open reading frames. Based upon this analysis, RT-PCR assays have been developed that can identify isolates displaying different symptoms and serotypes. The incorporation of primers in a multiplex PCR protocol permits rapid detection and discrimination among the strains. The results of PCR amplification using type-specific primers that amplify a portion of the coat protein gene demonstrate that the primer-selection procedure developed for PNRSV constitutes a reliable method of viral strain discrimination in cherry for disease control and will also be useful for examining biological diversity within the PNRSV virus group.

  8. Radon daughters and work at display devices

    International Nuclear Information System (INIS)

    Falk, R.; Nyblom, L.

    1986-01-01

    It has been shown that ions and electrically charged particles in the air can be transported in the electrostatic field between a face and a display device to either the face or the screen. Radon daughters can occur as ions, or sitting on charged particles. This prestudy shows that radon daughters were manifold concentrated on the face of a doll placed in front of a display device, or in a electrostatic field of the kind typical for displaying devices. The radiation dose, in the skin from the radon daughters in an ordinary office environment plus the addition caused by work at a display device, is not strong enough to cause skin damages alone. (BoK)

  9. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    A computerized display has been created for the Experimental Breeder Reactor II (EBR-II) that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of ionic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing the traditional rule and skill based behavior, and includes side benefits such a inherent signal validation

  10. Optimizing height presentation for aircraft cockpit displays

    Science.gov (United States)

    Jordan, Chris S.; Croft, D.; Selcon, Stephen J.; Markin, H.; Jackson, M.

    1997-02-01

    This paper describes an experiment conducted to investigate the type of display symbology that most effectively conveys height information to users of head-down plan-view radar displays. The experiment also investigated the use of multiple information sources (redundancy) in the design of such displays. Subjects were presented with eight different height display formats. These formats were constructed from a control, and/or one, two, or three sources of redundant information. The three formats were letter coding, analogue scaling, and toggling (spatially switching the position of the height information from above to below the aircraft symbol). Subjects were required to indicate altitude awareness via a four-key, forced-choice keyboard response. Error scores and response times were taken as performance measures. There were three main findings. First, there was a significant performance advantage when the altitude information was presented above and below the symbol to aid the representation of height information. Second, the analogue scale, a line whose length indicated altitude, proved significantly detrimental to performance. Finally, no relationship was found between the number of redundant information sources employed and performance. The implications for future aircraft and displays are discussed in relation to current aircraft tactical displays and in the context of perceptual psychological theory.

  11. View interpolation for medical images on autostereoscopic displays

    NARCIS (Netherlands)

    Zinger, S.; Ruijters, D.; Do, Q.L.; With, de P.H.N.

    2012-01-01

    We present an approach for efficient rendering and transmitting views to a high-resolution autostereoscopic display for medical purposes. Displaying biomedical images on an autostereoscopic display poses different requirements than in a consumer case. For medical usage, it is essential that the

  12. Cholesteric Liquid Crystal Based Reflex Color Reflective Displays

    Science.gov (United States)

    Khan, Asad

    2012-02-01

    Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer

  13. Interactive editing program using display

    International Nuclear Information System (INIS)

    Lang, I.; Ehsenski, J.; Namsraj, Yu.; Fefilov, B.V.

    1976-01-01

    A general description is given as well as principal functions are considered of 'DOSE' interactive editor program with a display involved. The program has been elaborated for TRA/1-1001 computer. This program enables one to edit and correct texts in algorithmical languages on a raster display screen as well as to provide perforated tapes for their further usage. 'DOSE' program is regarded as a basic program system for a set of TRA/1 and MINSK-32 computers

  14. Small - Display Cartography

    DEFF Research Database (Denmark)

    Nissen, Flemming; Hvas, Anders; Münster-Swendsen, Jørgen

    Service Communication and finally, Part IV: Concluding remarks and topics for further research on small-display cartography. Part II includes a separate Appendix D consisting of a cartographic design specification. Part III includes a separate Appendix C consisting of a schema specification, a separate...

  15. Wired World-Wide Web Interactive Remote Event Display

    Energy Technology Data Exchange (ETDEWEB)

    De Groot, Nicolo

    2003-05-07

    WIRED (World-Wide Web Interactive Remote Event Display) is a framework, written in the Java{trademark} language, for building High Energy Physics event displays. An event display based on the WIRED framework enables users of a HEP collaboration to visualize and analyze events remotely using ordinary WWW browsers, on any type of machine. In addition, event displays using WIRED may provide the general public with access to the research of high energy physics. The recent introduction of the object-oriented Java{trademark} language enables the transfer of machine independent code across the Internet, to be safely executed by a Java enhanced WWW browser. We have employed this technology to create a remote event display in WWW. The combined Java-WWW technology hence assures a world wide availability of such an event display, an always up-to-date program and a platform independent implementation, which is easy to use and to install.

  16. Optimizing direct response in Internet display advertising

    OpenAIRE

    Aksakallı, Vural

    2013-01-01

    Internet display advertising has grown into a multi-billion dollar a year global industry and direct response campaigns account for about three-quarters of all Internet display advertising. In such campaigns, advertisers reach out to a target audience via some form of a visual advertisement (hereinafter also called “ad”) to maximize short-term sales revenue. In this study, we formulate an advertiser’s revenue maximization problem in direct response Internet display advertisement campaigns as ...

  17. Online Display Advertising Causal Attribution and Evaluation

    OpenAIRE

    Barajas Zamora, Joel

    2015-01-01

    The allocation of a given budget to online display advertising as a marketing channel has motivated the development of statistical methods to measure its effectiveness. Recent studies show that display advertising often triggers online users to search for more information on products. Eventually, many of these users convert at the advertiser’s website. A key challenge is to measure the effectiveness of display advertising when users are exposed to multiple unknown advertising channels.We deve...

  18. Methods and apparatus for transparent display using scattering nanoparticles

    Science.gov (United States)

    Hsu, Chia Wei; Qiu, Wenjun; Zhen, Bo; Shapira, Ofer; Soljacic, Marin

    2016-05-10

    Transparent displays enable many useful applications, including heads-up displays for cars and aircraft as well as displays on eyeglasses and glass windows. Unfortunately, transparent displays made of organic light-emitting diodes are typically expensive and opaque. Heads-up displays often require fixed light sources and have limited viewing angles. And transparent displays that use frequency conversion are typically energy inefficient. Conversely, the present transparent displays operate by scattering visible light from resonant nanoparticles with narrowband scattering cross sections and small absorption cross sections. More specifically, projecting an image onto a transparent screen doped with nanoparticles that selectively scatter light at the image wavelength(s) yields an image on the screen visible to an observer. Because the nanoparticles scatter light at only certain wavelengths, the screen is practically transparent under ambient light. Exemplary transparent scattering displays can be simple, inexpensive, scalable to large sizes, viewable over wide angular ranges, energy efficient, and transparent simultaneously.

  19. Array display tool ADT reference manual. Version 1.2

    International Nuclear Information System (INIS)

    Evans, K. Jr.

    1995-12-01

    Array Display Tool (ADT) is a Motif program to display arrays of process variables from the Advanced Photon Source control system. A typical use is to display the horizontal and vertical monitor readings. A picture of the ADT interface is here. The screen layout, apart from the menu bar, consists of two types of graphic areas in which the values for the arrays of process variables are shown: Display areas, which display one or more arrays as a function of index, and a zoom area. In the zoom area specified arrays only are displayed as a function of lattice position along with symbols for the major elements of the lattice. There can be several display areas, but at most one zoom area. When the screen is resized these areas change size proportionally. There are a number of options in the View Menu to change the way the values are displayed. It is also possible via the Options Menu to: (1) Store the current values internally. (2) Store the values from a snapshot file internally. (3) Display one of the stored sets of values along with the current values. (4) Display the difference of the current values with one of the stored sets of values. (5) Write the current values to a snapshot file. There are several (currently 5) slots in which you can store values internally. In addition you can display the values with specified reference values subtracted

  20. Young Children's Responses to Guilt Displays

    Science.gov (United States)

    Vaish, Amrisha; Carpenter, Malinda; Tomasello, Michael

    2011-01-01

    Displaying guilt after a transgression serves to appease the victim and other group members, restore interpersonal relationships, and indicate the transgressors' awareness of and desire to conform to the group's norms. We investigated whether and when young children are sensitive to these functions of guilt displays. In Study 1, after 4- and…

  1. Pervasive displays understanding the future of digital signage

    CERN Document Server

    Davies, Nigel; Alt, Florian

    2014-01-01

    Fueled by falling display hardware costs and rising demand, digital signage and pervasive displays are becoming ever more ubiquitous. Such systems have traditionally been used for advertising and information dissemination, with digital signage commonplace in shopping malls, airports and public spaces. While advertising and broadcasting announcements remain important applications, developments in sensing and interaction technologies are enabling entirely new classes of display applications that tailor content to the situation and audience of the display. As a result, signage systems are beginni

  2. Securing information display by use of visual cryptography.

    Science.gov (United States)

    Yamamoto, Hirotsugu; Hayasaki, Yoshio; Nishida, Nobuo

    2003-09-01

    We propose a secure display technique based on visual cryptography. The proposed technique ensures the security of visual information. The display employs a decoding mask based on visual cryptography. Without the decoding mask, the displayed information cannot be viewed. The viewing zone is limited by the decoding mask so that only one person can view the information. We have developed a set of encryption codes to maintain the designed viewing zone and have demonstrated a display that provides a limited viewing zone.

  3. Unit information system operational displays for VVER-1000 reactors

    International Nuclear Information System (INIS)

    Anikanov, S.S.; Carrera, J.P.; Gordon, P.

    1997-01-01

    The role of high level operational displays is explained as well as the principles of the design of such displays. The tasks of WWER operating personnel are described and the support provided by operational displays is highlighted. The architecture of the displays is also dealt with. (A.K.)

  4. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    This paper reports on a computerized display that has been created for the Experimental Breeder Reactor II that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of iconic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing data for the traditional rule and skill based behavior, and includes side benefits such as inherent signal validation

  5. Policies toward advanced display in the Clinton administration

    Science.gov (United States)

    Hart, Jeffrey A.

    1994-04-01

    The Clinton administration is using its policy toward advanced displays as a test case for making industry-specific policies. They have established a number of criteria for advanced displays that they hope to apply to other industries in the future. For example, they want to support the development of generic technologies through ARPA and NIST, while minimizing the government's role in key business decisions. They want the industry (by which they mean the tool makers, the component assemblers, and the systems firms) to agree internally before they go ahead with their promotional policies. Given the past history of the advanced display industry, especially its disunity in regard to the enforcement of the successful antidumping petition of the Advanced Display Manufacturers Association and to efforts to create the U.S. Display Consortium, these criteria will be hard to meet. Nevertheless, there now appears to be much greater consensus among the three groups than in the past on the need to build indigenous technological capabilities in advanced displays.

  6. A programmable display layer for virtual reality system architectures.

    Science.gov (United States)

    Smit, Ferdi Alexander; van Liere, Robert; Froehlich, Bernd

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We describe an architecture that provides a programmable display layer (PDL) in order to generate updated display frames. This replaces the default display behavior of repeating application frames until an update is available. We will show three benefits of the architecture typical to VR. First, smooth motion is provided by generating intermediate display frames by per-pixel depth-image warping using 3D motion fields. Smooth motion eliminates various perceptual artifacts due to judder. Second, we implement fine-grained latency reduction at the display frame level using a synchronized prediction of simulation objects and the viewpoint. This improves the average quality and consistency of latency reduction. Third, a crosstalk reduction algorithm for consecutive display frames is implemented, which improves the quality of stereoscopic images. To evaluate the architecture, we compare image quality and latency to that of a classic level-of-detail approach.

  7. The Staphylococcus aureus Two-Component System AgrAC Displays Four Distinct Genomic Arrangements That Delineate Genomic Virulence Factor Signatures

    Directory of Open Access Journals (Sweden)

    Kumari S. Choudhary

    2018-05-01

    Full Text Available Two-component systems (TCSs consist of a histidine kinase and a response regulator. Here, we evaluated the conservation of the AgrAC TCS among 149 completely sequenced Staphylococcus aureus strains. It is composed of four genes: agrBDCA. We found that: (i AgrAC system (agr was found in all but one of the 149 strains, (ii the agr positive strains were further classified into four agr types based on AgrD protein sequences, (iii the four agr types not only specified the chromosomal arrangement of the agr genes but also the sequence divergence of AgrC histidine kinase protein, which confers signal specificity, (iv the sequence divergence was reflected in distinct structural properties especially in the transmembrane region and second extracellular binding domain, and (v there was a strong correlation between the agr type and the virulence genomic profile of the organism. Taken together, these results demonstrate that bioinformatic analysis of the agr locus leads to a classification system that correlates with the presence of virulence factors and protein structural properties.

  8. The Staphylococcus aureus Two-Component System AgrAC Displays Four Distinct Genomic Arrangements That Delineate Genomic Virulence Factor Signatures

    Science.gov (United States)

    Choudhary, Kumari S.; Mih, Nathan; Monk, Jonathan; Kavvas, Erol; Yurkovich, James T.; Sakoulas, George; Palsson, Bernhard O.

    2018-01-01

    Two-component systems (TCSs) consist of a histidine kinase and a response regulator. Here, we evaluated the conservation of the AgrAC TCS among 149 completely sequenced Staphylococcus aureus strains. It is composed of four genes: agrBDCA. We found that: (i) AgrAC system (agr) was found in all but one of the 149 strains, (ii) the agr positive strains were further classified into four agr types based on AgrD protein sequences, (iii) the four agr types not only specified the chromosomal arrangement of the agr genes but also the sequence divergence of AgrC histidine kinase protein, which confers signal specificity, (iv) the sequence divergence was reflected in distinct structural properties especially in the transmembrane region and second extracellular binding domain, and (v) there was a strong correlation between the agr type and the virulence genomic profile of the organism. Taken together, these results demonstrate that bioinformatic analysis of the agr locus leads to a classification system that correlates with the presence of virulence factors and protein structural properties. PMID:29887846

  9. Counselor Identity: Conformity or Distinction?

    Science.gov (United States)

    McLaughlin, Jerry E.; Boettcher, Kathryn

    2009-01-01

    The authors explore 3 debates in other disciplines similar to counseling's identity debate in order to learn about common themes and outcomes. Conformity, distinction, and cohesion emerged as common themes. They conclude that counselors should retain their distinctive, humanistic approach rather than conforming to the dominant, medical approach.

  10. A multi-viewer tiled autostereoscopic virtual reality display

    KAUST Repository

    Kooima, Robert; Prudhomme, Andrew; Schulze, Jurgen; Sandin, Daniel; DeFanti, Thomas

    2010-01-01

    Recognizing the value of autostereoscopy for 3D displays in public contexts, we pursue the goal of large-scale, high-resolution, immersive virtual reality using lenticular displays. Our contributions include the scalable tiling of lenticular displays to large fields of view and the use of GPU image interleaving and application optimization for real-time performance. In this context, we examine several ways to improve group-viewing by combining user tracking with multi-view displays. Copyright © 2010 by the Association for Computing Machinery, Inc.

  11. An Advanced Diagnostic Display for Core Protection Calculator System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2008-10-15

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed.

  12. An Advanced Diagnostic Display for Core Protection Calculator System

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do

    2008-01-01

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed

  13. Function-oriented display system: background and first prototypes

    International Nuclear Information System (INIS)

    Andresen, Gisle; Friberg, Maarten; Teigen, Arild; Pirus, Dominique

    2004-04-01

    The objective of the function-oriented displays and alarm project is to design, implement and evaluate Human System Interfaces (HSI) based on a function-oriented design philosophy. Function-oriented design is an approach for designing HSIs where the plant's functions, identified through a function analysis, are used for determining the content, organisation, and management of displays. The project has used the 'FITNESS approach', originally developed by EDF in France, as a starting point. FITNESS provides an integrated display system consisting of process operating displays, operating procedures, alarms and trend displays - all based on a functional decomposition of the plant. So far, two prototypes have been implemented on the FRESH PWR simulator in HAMMLAB. The first prototype focused on the condensate pumps. Three process operating displays representing functions at different levels of the functional hierarchy were implemented. Computerised startup and shutdown procedures for the condensate pumps function were also implemented. In the second prototype, the scope was increased to cover the main feedwater system. The displays of the first prototype were redesigned and additional displays were created. In conclusion, the first phase of the project has been completed successfully, and we are now ready to enter the second phase. In the second phase, the scope of the prototype will be increased further to include the steam-generators and function-oriented disturbance operating procedures. The prototype will be evaluated in a user test conducted later in 2004. (Author)

  14. Reflective and transflective liquid crystal displays

    Science.gov (United States)

    Zhou, Fushan

    Recently transflective liquid crystal displays (LCD) received a lot of attention. A transflective display has a transmissive mode and a reflective mode. It combines the high contrast, high brightness of the transmissive mode with energy-saving of reflective mode and has good performance in various illumination conditions. However, state-of-the-art transflective displays have problems such as different electro-optical properties, difficulty in compatibility and optimization of both modes, low efficiency of light utilization, and complexity in structure. This dissertation focuses on finding new designs of transflective displays that address those problems. One way to do this is to study film compensation of LCD. We first studied film compensation of bistable twisted nematic (BTN) LCD. Starting form the reduced (3x3) Mueller matrices, we derived and simplified the conditions that film compensated BTN can be optimized. Based on these relations, electro-optical properties of some particular configurations, and designs of transflective BTN with high brightness and contrast were given. To confirm and get a better understanding of the results, we use the Poincare sphere to analyze film compensated BTN. The key to this approach is the existence of "fixed points". Compared with the matrix approach, this approach is more simple, elegant, and efficient. We then generalized the Poincare sphere approach to a universal approach of LCD. We applied the universal approach to film compensation of ECB and IPS, and the design of achromatic birefringent filters. We also give two more new designs of transflective displays. In the first design, a dichroic mirror is used to split the visible spectrum into two parts used in transmissive and reflective modes, respectively. Both modes can be optimized. It has a simple structure and good light utilization. A design for a full-color transflective display with good performance is also given. In the second design, each pixel is divided into two

  15. Structural brain alterations associated with schizophrenia preceded by conduct disorder: a common and distinct subtype of schizophrenia?

    Science.gov (United States)

    Schiffer, Boris; Leygraf, Norbert; Müller, Bernhard W; Scherbaum, Norbert; Forsting, Michael; Wiltfang, Jens; Gizewski, Elke R; Hodgins, Sheilagh

    2013-09-01

    Conduct disorder (CD) prior to age 15 is a precursor of schizophrenia in a minority of cases and is associated with violent behavior through adulthood, after taking account of substance misuse. The present study used structural magnetic imaging to examine gray matter (GM) volumes among 27 men with schizophrenia preceded by CD (SZ+CD), 23 men with schizophrenia but without CD (SZ-CD), 27 men with CD only (CD), and 25 healthy (H) men. The groups with schizophrenia were similar in terms of age of onset and duration of illness, levels of psychotic symptoms, and medication. The 2 groups with CD were similar as to number of CD symptoms, lifelong aggressive behavior, and number of criminal convictions. Men with SZ+CD, relative to those with SZ-CD, displayed (1) increased GM volumes in the hypothalamus, the left putamen, the right cuneus/precuneus, and the right inferior parietal cortex after controlling for age, alcohol, and drug misuse and (2) decreased GM volumes in the inferior frontal region. Men with SZ+CD (relative to the SZ-CD group) and CD (relative to the H group) displayed increased GM volumes of the hypothalamus and the inferior and superior parietal lobes, which were not associated with substance misuse. Aggressive behavior, both prior to age 15 and lifetime tendency, was positively correlated with the GM volume of the hypothalamus. Thus, among males, SZ+CD represents a distinct subtype of schizophrenia. Although differences in behavior emerge in childhood and remain stable through adulthood, further research is needed to determine whether the differences in GM volumes result from abnormal neural development distinct from that of other males developing schizophrenia.

  16. A kinesthetic-tactual display for stall deterrence

    Science.gov (United States)

    Gilson, R. D.; Ventola, R. W.; Fenton, R. E.

    1975-01-01

    A kinesthetic tactual display may be effectively used as a control aid per previous flight tests. Angle of attack information would be continuously presented to a pilot, via this display, during critical operational phases where stalls are probable. A two phase plan for evaluating this concept is presented. A first development phase would encompass: (1) display fabrication for a conventional control yoke; (2) its installation, together with other necessary instrumentation, in an experimental aircraft; and (3) preliminary flight testing by experienced pilots.

  17. Illuminant-adaptive color reproduction for mobile display

    Science.gov (United States)

    Kim, Jong-Man; Park, Kee-Hyon; Kwon, Oh-Seol; Cho, Yang-Ho; Ha, Yeong-Ho

    2006-01-01

    This paper proposes an illuminant-adaptive reproduction method using light adaptation and flare conditions for a mobile display. Mobile displays, such as PDAs and cellular phones, are viewed under various lighting conditions. In particular, images displayed in daylight are perceived as quite dark due to the light adaptation of the human visual system, as the luminance of a mobile display is considerably lower than that of an outdoor environment. In addition, flare phenomena decrease the color gamut of a mobile display by increasing the luminance of dark areas and de-saturating the chroma. Therefore, this paper presents an enhancement method composed of lightness enhancement and chroma compensation. First, the ambient light intensity is measured using a lux-sensor, then the flare is calculated based on the reflection ratio of the display device and the ambient light intensity. The relative cone response is nonlinear to the input luminance. This is also changed by the ambient light intensity. Thus, to improve the perceived image, the displayed luminance is enhanced by lightness linearization. In this paper, the image's luminance is transformed by linearization of the response to the input luminance according to the ambient light intensity. Next, the displayed image is compensated according to the physically reduced chroma, resulting from flare phenomena. The reduced chroma value is calculated according to the flare for each intensity. The chroma compensation method to maintain the original image's chroma is applied differently for each hue plane, as the flare affects each hue plane differently. At this time, the enhanced chroma also considers the gamut boundary. Based on experimental observations, the outer luminance-intensity generally ranges from 1,000 lux to 30,000 lux. Thus, in the case of an outdoor environment, i.e. greater than 1,000 lux, this study presents a color reproduction method based on an inverse cone response curve and flare condition. Consequently

  18. Improvements in or relating to information display arrangements

    International Nuclear Information System (INIS)

    Blay, A.G.

    1975-01-01

    An information display arrangement for use in biomedical radiography with either X- or γ-radiation or ultrasonic waves is described. This invention overcomes the drawbacks of conventional three-dimensional displays where certain features may be partially or completely obscured from view by matter which is not of interest. This improvement is achieved by interactive means using a light pen on a cathode ray tube display to effectively draw boundaries between relevant and irrelevant features. The computerised display is then up-dated from the information store containing the transmission data. (U.K.)

  19. Visual Attention to Radar Displays

    Science.gov (United States)

    Moray, N.; Richards, M.; Brophy, C.

    1984-01-01

    A model is described which predicts the allocation of attention to the features of a radar display. It uses the growth of uncertainty and the probability of near collision to call the eye to a feature of the display. The main source of uncertainty is forgetting following a fixation, which is modelled as a two dimensional diffusion process. The model was used to predict information overload in intercept controllers, and preliminary validation obtained by recording eye movements of intercept controllers in simulated and live (practice) interception.

  20. Facial Displays Are Tools for Social Influence.

    Science.gov (United States)

    Crivelli, Carlos; Fridlund, Alan J

    2018-05-01

    Based on modern theories of signal evolution and animal communication, the behavioral ecology view of facial displays (BECV) reconceives our 'facial expressions of emotion' as social tools that serve as lead signs to contingent action in social negotiation. BECV offers an externalist, functionalist view of facial displays that is not bound to Western conceptions about either expressions or emotions. It easily accommodates recent findings of diversity in facial displays, their public context-dependency, and the curious but common occurrence of solitary facial behavior. Finally, BECV restores continuity of human facial behavior research with modern functional accounts of non-human communication, and provides a non-mentalistic account of facial displays well-suited to new developments in artificial intelligence and social robotics. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. General multiplex centralized fire-alarm display system

    International Nuclear Information System (INIS)

    Zhu Liqun; Chen Jinming

    2002-01-01

    The fire-alarm display system is developed, which can connect with each type of fire controllers produced in the factory and SIGMASYS controllers. It can display whole alarm information. The display system software gathers communication, database and multimedia, has functions of inspecting fire, showing alarm, storing data, searching information and so on. The drawing software lets the user expediently add, delete, move and modify fire detection or fire fighting facilities on the building floor maps. The graphic transform software lets the display use the vectorgraph produced by popular plotting software such as Auto CAD. The system software provides the administration function, such as log book of changing shift and managing workers etc.. The software executed on Windows 98 platform. The user interface is friendly and reliable in operation

  2. Third-Generation Display Technology: Nominally Transparent Material

    Directory of Open Access Journals (Sweden)

    Charles Willow

    2010-12-01

    Full Text Available Display technology is reshaping the consumer, business, government, and even not-for-profit markets in the midst of the digital convergence, coupled with recent smart phones led by Apple, Inc. First-Generation (1G display technology was dominated by the Cathode Ray Tubes, followed by Liquid Crystal Display and Plasma in 2G. A radically innovative shift as a disruptive technology is expected to follow in 3G to utilize virtually any transparent material, which wirelessly connects to portable access points. This paper studies the feasibility of the 3G Display Technology (DT with Technology S-Curves, and presents possible business models and technology strategies which may be generated from it. Additional subsets of business models may be derived for a wide range of industry applications.

  3. Head Worn Display System for Equivalent Visual Operations

    Science.gov (United States)

    Cupero, Frank; Valimont, Brian; Wise, John; Best. Carl; DeMers, Bob

    2009-01-01

    Head-Worn Displays or so-called, near-to-eye displays have potentially significant advantages in terms of cost, overcoming cockpit space constraints, and for the display of spatially-integrated information. However, many technical issues need to be overcome before these technologies can be successfully introduced into commercial aircraft cockpits. The results of three activities are reported. First, the near-to-eye display design, technological, and human factors issues are described and a literature review is presented. Second, the results of a fixed-base piloted simulation, investigating the impact of near to eye displays on both operational and visual performance is reported. Straight-in approaches were flown in simulated visual and instrument conditions while using either a biocular or a monocular display placed on either the dominant or non-dominant eye. The pilot's flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested. The data generally supports a monocular design with minimal impact due to eye dominance. Finally, a method for head tracker system latency measurement is developed and used to compare two different devices.

  4. Scream-embrace displays in wild black-horned capuchin monkeys.

    Science.gov (United States)

    Lynch Alfaro, Jessica

    2008-06-01

    Reintroduction of capuchin monkeys (Cebus apella) into their social group in captivity can elicit sirena screams and embraces. Captive scream-embrace displays are male biased, and females never perform sirena screams. One hypothesis is that scream-embrace displays serve a tension-reduction or reconciliatory function between males with conflicting interests. Alternatively, these displays may function to maintain strong affiliative bonds between friendly male dyads. Scream and/or embrace displays in wild Brazilian black-horned capuchins were analyzed for social and ecological contexts, behavioral components, and individuals involved. Seventy-two displays were observed during the 199-day study period. Among the 66 displays for which both members could be identified by sex, there were 42 occurrences of male-male dyads, 17 of male-female dyads, and seven of female-female dyads. Scream-embrace dyads were male-male pairs significantly more often than expected from group membership, and the alpha male was the only male to engage in scream-embrace displays with females. Female-female pairs did embrace, but never emitted sirena screams. Displays most commonly occurred in "reunion" contexts, primarily the reuniting of subgroups after hours or days out of contact, but also after intergroup encounters, and across groups in "intergroup" displays. Displays were rare, but socially contagious, and subgroup reunions could elicit multiple displays in rapid succession. Although the occurrence of screams and embraces was positively correlated, both behaviors also occurred independently, and their functions may be different. Male sirena screams may be honest advertisements of united alliances, directed toward a third party, whereas the embrace may be a risky affiliative signal, directed primarily within the dyad. Copyright 2008 Wiley-Liss, Inc.

  5. An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

    Science.gov (United States)

    Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.

    2015-01-01

    A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the

  6. Drag and drop display & builder

    Energy Technology Data Exchange (ETDEWEB)

    Bolshakov, Timofei B.; Petrov, Andrey D.; /Fermilab

    2007-12-01

    The Drag and Drop (DnD) Display & Builder is a component-oriented system that allows users to create visual representations of data received from data acquisition systems. It is an upgrade of a Synoptic Display mechanism used at Fermilab since 2002. Components can be graphically arranged and logically interconnected in the web-startable Project Builder. Projects can be either lightweight AJAX- and SVG-based web pages, or they can be started as Java applications. The new version was initiated as a response to discussions between the LHC Controls Group and Fermilab.

  7. Recent progress in OLED and flexible displays and their potential for application to aerospace and military display systems

    Science.gov (United States)

    Sarma, Kalluri

    2015-05-01

    Organic light emitting diode (OLED) display technology has advanced significantly in recent years and it is increasingly being adapted in consumer electronics products with premium performance, such as high resolution smart phones, Tablet PCs and TVs. Even flexible OLED displays are beginning to be commercialized in consumer electronic devices such as smart phones and smart watches. In addition to the advances in OLED emitters, successful development and adoption of OLED displays for premium performance applications relies on the advances in several enabling technologies including TFT backplanes, pixel drive electronics, pixel patterning technologies, encapsulation technologies and system level engineering. In this paper we will discuss the impact of the recent advances in LTPS and AOS TFTs, R, G, B and White OLED with color filter pixel architectures, and encapsulation, on the success of the OLEDs in consumer electronic devices. We will then discuss potential of these advances in addressing the requirements of OLED and flexible displays for the military and avionics applications.

  8. An integrated acquisition, display, and analysis system

    International Nuclear Information System (INIS)

    Ahmad, T.; Huckins, R.J.

    1987-01-01

    The design goal of the ND9900/Genuie was to integrate a high performance data acquisition and display subsystem with a state-of-the-art 32-bit supermicrocomputer. This was achieved by integrating a Digital Equipment Corporation MicroVAX II CPU board with acquisition and display controllers via the Q-bus. The result is a tightly coupled processing and analysis system for Pulse Height Analysis and other applications. The system architecture supports distributed processing, so that acquisition and display functions are semi-autonomous, making the VAX concurrently available for applications programs

  9. Review of defense display research programs

    Science.gov (United States)

    Tulis, Robert W.; Hopper, Darrel G.; Morton, David C.; Shashidhar, Ranganathan

    2001-09-01

    Display research has comprised a substantial portion of the defense investment in new technology for national security for the past 13 years. These investments have been made by the separate service departments and, especially, via several Defense Research Projects Agency (DARPA) programs, known collectively as the High Definition Systems (HDS) Program (which ended in 2001) and via the Office of the Secretary of Defense (OSD) Defense Production Act (DPA) Title III Program (efforts ended in 2000). Using input from the Army, Navy, and Air Force to focus research and identify insertion opportunities, DARPA and the Title III Program Office have made investments to develop the national technology base and manufacturing infrastructure necessary to meet the twin challenge of providing affordable displays in current systems and enabling the DoD strategy of winning future conflicts by getting more information to all participants during the battle. These completed DARPA and DPA research and infrastructure programs are reviewed. Service investments have been and are being made to transition display technology; examples are described. Display science and technology (S&T) visions are documented for each service to assist the identification of areas meriting consideration for future defense research.

  10. 3D Display of Spacecraft Dynamics Using Real Telemetry

    Directory of Open Access Journals (Sweden)

    Sanguk Lee

    2002-12-01

    Full Text Available 3D display of spacecraft motion by using telemetry data received from satellite in real-time is described. Telemetry data are converted to the appropriate form for 3-D display by the real-time preprocessor. Stored playback telemetry data also can be processed for the display. 3D display of spacecraft motion by using real telemetry data provides intuitive comprehension of spacecraft dynamics.

  11. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  12. Distinct herpesvirus resistances and immune responses of three gynogenetic clones of gibel carp revealed by comprehensive transcriptomes.

    Science.gov (United States)

    Gao, Fan-Xiang; Wang, Yang; Zhang, Qi-Ya; Mou, Cheng-Yan; Li, Zhi; Deng, Yuan-Sheng; Zhou, Li; Gui, Jian-Fang

    2017-07-24

    Gibel carp is an important aquaculture species in China, and a herpesvirus, called as Carassius auratus herpesvirus (CaHV), has hampered the aquaculture development. Diverse gynogenetic clones of gibel carp have been identified or created, and some of them have been used as aquaculture varieties, but their resistances to herpesvirus and the underlying mechanism remain unknown. To reveal their susceptibility differences, we firstly performed herpesvirus challenge experiments in three gynogenetic clones of gibel carp, including the leading variety clone A + , candidate variety clone F and wild clone H. Three clones showed distinct resistances to CaHV. Moreover, 8772, 8679 and 10,982 differentially expressed unigenes (DEUs) were identified from comparative transcriptomes between diseased individuals and control individuals of clone A + , F and H, respectively. Comprehensive analysis of the shared DEUs in all three clones displayed common defense pathways to the herpesvirus infection, activating IFN system and suppressing complements. KEGG pathway analysis of specifically changed DEUs in respective clones revealed distinct immune responses to the herpesvirus infection. The DEU numbers identified from clone H in KEGG immune-related pathways, such as "chemokine signaling pathway", "Toll-like receptor signaling pathway" and others, were remarkably much more than those from clone A + and F. Several IFN-related genes, including Mx1, viperin, PKR and others, showed higher increases in the resistant clone H than that in the others. IFNphi3, IFI44-like and Gig2 displayed the highest expression in clone F and IRF1 uniquely increased in susceptible clone A + . In contrast to strong immune defense in resistant clone H, susceptible clone A + showed remarkable up-regulation of genes related to apoptosis or death, indicating that clone A + failed to resist virus offensive and evidently induced apoptosis or death. Our study is the first attempt to screen distinct resistances and

  13. Visual Neurons in the Superior Colliculus Innervated by Islet2+ or Islet2− Retinal Ganglion Cells Display Distinct Tuning Properties

    Directory of Open Access Journals (Sweden)

    Rachel B. Kay

    2017-10-01

    Full Text Available Throughout the visual system, different subtypes of neurons are tuned to distinct aspects of the visual scene, establishing parallel circuits. Defining the mechanisms by which such tuning arises has been a long-standing challenge for neuroscience. To investigate this, we have focused on the retina’s projection to the superior colliculus (SC, where multiple visual neuron subtypes have been described. The SC receives inputs from a variety of retinal ganglion cell (RGC subtypes; however, which RGCs drive the tuning of different SC neurons remains unclear. Here, we pursued a genetic approach that allowed us to determine the tuning properties of neurons innervated by molecularly defined subpopulations of RGCs. In homozygous Islet2-EphA3 knock-in (Isl2EA3/EA3 mice, Isl2+ and Isl2− RGCs project to non-overlapping sub-regions of the SC. Based on molecular and anatomic data, we show that significantly more Isl2− RGCs are direction-selective (DS in comparison with Isl2+ RGCs. Targeted recordings of visual responses from each SC sub-region in Isl2EA3/EA3 mice revealed that Isl2− RGC-innervated neurons were significantly more DS than those innervated by Isl2+ RGCs. Axis-selective (AS neurons were found in both sub-regions, though AS neurons innervated by Isl2+ RGCs were more tightly tuned. Despite this segregation, DS and AS neurons innervated by Isl2+ or Isl2− RGCs did not differ in their spatial summation or spatial frequency (SF tuning. Further, we did not observe alterations in receptive field (RF size or structure of SC neurons innervated by Isl2+ or Isl2− RGCs. Together, these data show that innervation by Isl2+ and Isl2− RGCs results in distinct tuning in the SC and set the stage for future studies investigating the mechanisms by which these circuits are built.

  14. ENERGY STAR Certified Displays

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 7.0 ENERGY STAR Program Requirements for Displays that are effective as of July 1, 2016....

  15. The Real Time Interactive Display Environment (RTIDE), a display building tool developed by Space Shuttle flight controllers

    Science.gov (United States)

    Kalvelage, Thomas A.

    1989-01-01

    NASA's Mission Control Center, located at Johnson Space Center, is incrementally moving from a centralized architecture to a distributed architecture. Starting with STS-29, some host-driven console screens will be replaced with graphics terminals driven by workstations. These workstations will be supplied realtime data first by the Real Time Data System (RTDS), a system developed inhouse, and then months later (in parallel with RTDS) by interim and subsequently operational versions of the Mission Control Center Upgrade (MCCU) software package. The Real Time Interactive Display Environment (RTIDE) was built by Space Shuttle flight controllers to support the rapid development of multiple new displays to support Shuttle flights. RTIDE is a display building tool that allows non-programmers to define object-oriented, event-driven, mouseable displays. Particular emphasis was placed on upward compatibility between RTIDE versions, ability to acquire data from different data sources, realtime performance, ability to modularly upgrade RTIDE, machine portability, and a clean, powerful user interface. The operational and organizational factors that drove RTIDE to its present form, the actual design itself, simulation and flight performance, and lessons learned in the process are discussed.

  16. Advanced Plasmonic Materials for Dynamic Color Display.

    Science.gov (United States)

    Shao, Lei; Zhuo, Xiaolu; Wang, Jianfang

    2018-04-01

    Plasmonic structures exhibit promising applications in high-resolution and durable color generation. Research on advanced hybrid plasmonic materials that allow dynamically reconfigurable color control has developed rapidly in recent years. Some of these results may give rise to practically applicable reflective displays in living colors with high performance and low power consumption. They will attract broad interest from display markets, compared with static plasmonic color printing, for example, in applications such as digital signage, full-color electronic paper, and electronic device screens. In this progress report, the most promising recent examples of utilizing advanced plasmonic materials for the realization of dynamic color display are highlighted and put into perspective. The performances, advantages, and disadvantages of different technologies are discussed, with emphasis placed on both the potential and possible limitations of various hybrid materials for dynamic plasmonic color display. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Identifying Bacterial Immune Evasion Proteins Using Phage Display.

    Science.gov (United States)

    Fevre, Cindy; Scheepmaker, Lisette; Haas, Pieter-Jan

    2017-01-01

    Methods aimed at identification of immune evasion proteins are mainly rely on in silico prediction of sequence, structural homology to known evasion proteins or use a proteomics driven approach. Although proven successful these methods are limited by a low efficiency and or lack of functional identification. Here we describe a high-throughput genomic strategy to functionally identify bacterial immune evasion proteins using phage display technology. Genomic bacterial DNA is randomly fragmented and ligated into a phage display vector that is used to create a phage display library expressing bacterial secreted and membrane bound proteins. This library is used to select displayed bacterial secretome proteins that interact with host immune components.

  18. Human factors guidelines for large-screen displays

    International Nuclear Information System (INIS)

    Collier, Steve

    2005-09-01

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  19. Human factors guidelines for large-screen displays

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Steve

    2005-09-15

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  20. Real-time Image Generation for Compressive Light Field Displays

    International Nuclear Information System (INIS)

    Wetzstein, G; Lanman, D; Hirsch, M; Raskar, R

    2013-01-01

    With the invention of integral imaging and parallax barriers in the beginning of the 20th century, glasses-free 3D displays have become feasible. Only today—more than a century later—glasses-free 3D displays are finally emerging in the consumer market. The technologies being employed in current-generation devices, however, are fundamentally the same as what was invented 100 years ago. With rapid advances in optical fabrication, digital processing power, and computational perception, a new generation of display technology is emerging: compressive displays exploring the co-design of optical elements and computational processing while taking particular characteristics of the human visual system into account. In this paper, we discuss real-time implementation strategies for emerging compressive light field displays. We consider displays composed of multiple stacked layers of light-attenuating or polarization-rotating layers, such as LCDs. The involved image generation requires iterative tomographic image synthesis. We demonstrate that, for the case of light field display, computed tomographic light field synthesis maps well to operations included in the standard graphics pipeline, facilitating efficient GPU-based implementations with real-time framerates.

  1. Hewlett-Packard's Approaches to Full Color Reflective Displays

    Science.gov (United States)

    Gibson, Gary

    2012-02-01

    Reflective displays are desirable in applications requiring low power or daylight readability. However, commercial reflective displays are currently either monochrome or capable of only dim color gamuts. Low cost, high-quality color technology would be rapidly adopted in existing reflective display markets and would enable new solutions in areas such as retail pricing and outdoor digital signage. Technical breakthroughs are required to enable bright color gamuts at reasonable cost. Pixel architectures that rely on pure reflection from a single layer of side-by-side primary-color sub-pixels use only a fraction of the display area to reflect incident light of a given color and are, therefore, unacceptably dark. Reflective devices employing stacked color primaries offer the possibility of a somewhat brighter color gamut but can be more complex to manufacture. In this talk, we describe HP's successes in addressing these fundamental challenges and creating both high performance stacked-primary reflective color displays as well as inexpensive single layer prototypes that provide good color. Our stacked displays utilize a combination of careful light management techniques, proprietary high-contrast electro-optic shutters, and highly transparent active-matrix TFT arrays based on transparent metal oxides. They also offer the possibility of relatively low cost manufacturing through roll-to-roll processing on plastic webs. To create even lower cost color displays with acceptable brightness, we have developed means for utilizing photoluminescence to make more efficient use of ambient light in a single layer device. Existing reflective displays create a desired color by reflecting a portion of the incident spectrum while absorbing undesired wavelengths. We have developed methods for converting the otherwise-wasted absorbed light to desired wavelengths via tailored photoluminescent composites. Here we describe a single active layer prototype display that utilizes these materials

  2. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  3. Co-circulation of multiple hemorrhagic fever diseases with distinct clinical characteristics in Dandong, China.

    Directory of Open Access Journals (Sweden)

    Zhi-Hai Chen

    Full Text Available Hemorrhagic fevers (HF caused by viruses and bacteria are a major public health problem in China and characterized by variable clinical manifestations, such that it is often difficult to achieve accurate diagnosis and treatment. The causes of HF in 85 patients admitted to Dandong hospital, China, between 2011-2012 were determined by serological and PCR tests. Of these, 34 patients were diagnosed with Huaiyangshan hemorrhagic fever (HYSHF, 34 with Hemorrhagic Fever with Renal Syndrome (HFRS, one with murine typhus, and one with scrub typhus. Etiologic agents could not be determined in the 15 remaining patients. Phylogenetic analyses of recovered bacterial and viral sequences revealed that the causative infectious agents were closely related to those described in other geographical regions. As these diseases have no distinctive clinical features in their early stage, only 13 patients were initially accurately diagnosed. The distinctive clinical features of HFRS and HYSHF developed during disease progression. Enlarged lymph nodes, cough, sputum, and diarrhea were more common in HYSHF patients, while more HFRS cases presented with headache, sore throat, oliguria, percussion pain kidney area, and petechiae. Additionally, HYSHF patients displayed significantly lower levels of white blood cells (WBC, higher levels of creations kinase (CK and alanine aminotransferase (ALT, while HFRS patients presented with an elevation of blood urea nitrogen (BUN and creatinine (CREA. These clinical features will assist in the accurate diagnosis of both HYSHF and HFRS. Overall, our data reveal the complexity of pathogens causing HFs in a single Chinese hospital, and highlight the need for accurate early diagnosis and a better understanding of their distinctive clinical features.

  4. 3D Image Display Courses for Information Media Students.

    Science.gov (United States)

    Yanaka, Kazuhisa; Yamanouchi, Toshiaki

    2016-01-01

    Three-dimensional displays are used extensively in movies and games. These displays are also essential in mixed reality, where virtual and real spaces overlap. Therefore, engineers and creators should be trained to master 3D display technologies. For this reason, the Department of Information Media at the Kanagawa Institute of Technology has launched two 3D image display courses specifically designed for students who aim to become information media engineers and creators.

  5. Lateralisation of aggressive displays in a tephritid fly

    Science.gov (United States)

    Benelli, Giovanni; Donati, Elisa; Romano, Donato; Stefanini, Cesare; Messing, Russell H.; Canale, Angelo

    2015-02-01

    Lateralisation (i.e. different functional and/or structural specialisations of the left and right sides of the brain) of aggression has been examined in several vertebrate species, while evidence for invertebrates is scarce. In this study, we investigated lateralisation of aggressive displays (boxing with forelegs and wing strikes) in the Mediterranean fruit fly, Ceratitis capitata. We attempted to answer the following questions: (1) do medflies show lateralisation of aggressive displays at the population-level; (2) are there sex differences in lateralisation of aggressive displays; and (3) does lateralisation of aggression enhance fighting success? Results showed left-biased population-level lateralisation of aggressive displays, with no consistent differences among sexes. In both male-male and female-female conflicts, aggressive behaviours performed with left body parts led to greater fighting success than those performed with right body parts. As we found left-biased preferential use of body parts for both wing strikes and boxing, we predicted that the left foreleg/wing is quicker in exploring/striking than the right one. We characterised wing strike and boxing using high-speed videos, calculating mean velocity of aggressive displays. For both sexes, aggressive displays that led to success were faster than unsuccessful ones. However, left wing/legs were not faster than right ones while performing aggressive acts. Further research is needed on proximate causes allowing enhanced fighting success of lateralised aggressive behaviour. This is the first report supporting the adaptive role of lateralisation of aggressive displays in insects.

  6. A green-color portable waveguide eyewear display system

    Science.gov (United States)

    Xia, Lingbo; Xu, Ke; Wu, Zhengming; Hu, Yingtian; Li, Zhenzhen; Wang, Yongtian; Liu, Juan

    2013-08-01

    Waveguide display systems are widely used in various display fields, especially in head mounted display. Comparing with the traditional head mounted display system, this device dramatically reduce the size and mass. However, there are still several fatal problems such as high scatting, the cumbersome design and chromatic aberration that should be solved. We designed and fabricated a monochromatic portable eyewear display system consist of a comfortable eyewear device and waveguide system with two holographic gratings located on the substrate symmetrically. We record the gratings on the photopolymer medium with high efficiency and wavelength sensitivity. The light emitting from the micro-display is diffracted by the grating and trapped in the glass substrate by total internal reflection. The relationship between the diffraction efficiency and exposure value is studied and analyzed, and we fabricated the gratings with appropriate diffraction efficiency in a optimization condition. To avoid the disturbance of the stray light, we optimize the waveguide system numerically and perform the optical experiments. With this system, people can both see through the waveguide to obtain the information outside and catch the information from the micro display. After considering the human body engineering and industrial production, we design the structure in a compact and portable way. It has the advantage of small-type configuration and economic acceptable. It is believe that this kind of planar waveguide system is a potentially replaceable choice for the portable devices in future mobile communications.

  7. A Qualitative Method to Estimate HSI Display Complexity

    International Nuclear Information System (INIS)

    Hugo, Jacques; Gertman, David

    2013-01-01

    There is mounting evidence that complex computer system displays in control rooms contribute to cognitive complexity and, thus, to the probability of human error. Research shows that reaction time increases and response accuracy decreases as the number of elements in the display screen increase. However, in terms of supporting the control room operator, approaches focusing on addressing display complexity solely in terms of information density and its location and patterning, will fall short of delivering a properly designed interface. This paper argues that information complexity and semantic complexity are mandatory components when considering display complexity and that the addition of these concepts assists in understanding and resolving differences between designers and the preferences and performance of operators. This paper concludes that a number of simplified methods, when combined, can be used to estimate the impact that a particular display may have on the operator's ability to perform a function accurately and effectively. We present a mixed qualitative and quantitative approach and a method for complexity estimation

  8. 14 CFR 147.39 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 147.39 Section 147...) SCHOOLS AND OTHER CERTIFICATED AGENCIES AVIATION MAINTENANCE TECHNICIAN SCHOOLS Operating Rules § 147.39 Display of certificate. Each holder of an aviation maintenance technician school certificate and ratings...

  9. Development and validation of novel AAV2 random libraries displaying peptides of diverse lengths and at diverse capsid positions.

    Science.gov (United States)

    Naumer, Matthias; Ying, Ying; Michelfelder, Stefan; Reuter, Antje; Trepel, Martin; Müller, Oliver J; Kleinschmidt, Jürgen A

    2012-05-01

    Libraries based on the insertion of random peptide ligands into the capsid of adeno-associated virus type 2 (AAV2) have been widely used to improve the efficiency and selectivity of the AAV vector system. However, so far only libraries of 7-mer peptide ligands have been inserted at one well-characterized capsid position. Here, we expanded the combinatorial AAV2 display system to a panel of novel AAV libraries, displaying peptides of 5, 7, 12, 19, or 26 amino acids in length at capsid position 588 or displaying 7-mer peptides at position 453, the most prominently exposed region of the viral capsid. Library selections on two unrelated cell types-human coronary artery endothelial cells and rat cardiomyoblasts-revealed the isolation of cell type-characteristic peptides of different lengths mediating strongly improved target-cell transduction, except for the 26-mer peptide ligands. Characterization of vector selectivity by transduction of nontarget cells and comparative gene-transduction analysis using a panel of 44 human tumor cell lines revealed that insertion of different-length peptides allows targeting of distinct cellular receptors for cell entry with similar efficiency, but with different selectivity. The application of such novel AAV2 libraries broadens the spectrum of targetable receptors by capsid-modified AAV vectors and provides the opportunity to choose the best suited targeting ligand for a certain application from a number of different candidates.

  10. A ROOT based event display software for JUNO

    Science.gov (United States)

    You, Z.; Li, K.; Zhang, Y.; Zhu, J.; Lin, T.; Li, W.

    2018-02-01

    An event display software SERENA has been designed for the Jiangmen Underground Neutrino Observatory (JUNO). The software has been developed in the JUNO offline software system and is based on the ROOT display package EVE. It provides an essential tool to display detector and event data for better understanding of the processes in the detectors. The software has been widely used in JUNO detector optimization, simulation, reconstruction and physics study.

  11. Liquid Crystal Microlenses for Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    José Francisco Algorri

    2016-01-01

    Full Text Available Three-dimensional vision has acquired great importance in the audiovisual industry in the past ten years. Despite this, the first generation of autostereoscopic displays failed to generate enough consumer excitement. Some reasons are little 3D content and performance issues. For this reason, an exponential increase in three-dimensional vision research has occurred in the last few years. In this review, a study of the historical impact of the most important technologies has been performed. This study is carried out in terms of research manuscripts per year. The results reveal that research on spatial multiplexing technique is increasing considerably and today is the most studied. For this reason, the state of the art of this technique is presented. The use of microlenses seems to be the most successful method to obtain autostereoscopic vision. When they are fabricated with liquid crystal materials, extended capabilities are produced. Among the numerous techniques for manufacturing liquid crystal microlenses, this review covers the most viable designs for its use in autostereoscopic displays. For this reason, some of the most important topologies and their relation with autostereoscopic displays are presented. Finally, the challenges in some recent applications, such as portable devices, and the future of three-dimensional displays based on liquid crystal microlenses are outlined.

  12. A wearable navigation display can improve attentiveness to the surgical field.

    Science.gov (United States)

    Stewart, James; Billinghurst, Mark

    2016-06-01

    Surgical navigation is typically shown on a computer display that is distant from the patient, making it difficult for the surgeon to watch the patient while performing a guided task. We investigate whether a light-weight, untracked, wearable display (such as Google Glass, which has the same size and weight as corrective glasses) can improve attentiveness to the surgical field in a simulated surgical task. Three displays were tested: a computer monitor; a peripheral display above the eye; and a through-the-lens display in front of the eye. Twelve subjects performed a task to position and orient a tracked tool on a plastic femur. Both wearable displays were tested on the dominant and non-dominant eyes of each subject. Attentiveness during the task was measured by the time taken to respond to randomly illuminated LEDs on the femur. Attentiveness was improved with the wearable displays at the cost of a decrease in accuracy. The through-the-lens display performed better than the peripheral display. The peripheral display performed better when on the dominant eye, while the through-the-lens display performed better when on the non-dominant eye. Attentiveness to the surgical field can be improved with the use of a light-weight, untracked, wearable display. A through-the-lens display performs better than a peripheral display, and both perform better than a computer monitor. Eye dominance should be considered when positioning the display.

  13. Evaluation of technical design of advanced information display(III)

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol; Park, Soon Hyuk

    2005-02-01

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines

  14. Evaluation of technical design of advanced information display(III)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol [Kumoh National Institute of Technology, Gumi (Korea, Republic of); Park, Soon Hyuk [DNT Inc., Daejeon (Korea, Republic of)

    2005-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines.

  15. Varifocal mirror display of organ surfaces from CT scans

    International Nuclear Information System (INIS)

    Pizer, S.M.; Fuchs, H.; Bloomberg, S.H.; Li Ching Tsai; Heinz, E.R.

    1982-01-01

    A means will be presented of constructing a powerful varifocal mirror 3D display system with limited cost based on an ordinary color video digital display system. The importance of dynamic interactive control of the display of these images will be discussed; in particular, the design and usefulness of a method allowing real-time user-controlled motion of the 3D object being displayed will be discussed. Also, an effective method will be described of presenting images made of surfaces by the straightforward, automatic calculation of 3D edge strength, the ordering of the resulting voxels by edge strength, and the 3D grey-scale display of the top voxels on this ordered list. The application of these ideas to the 3D display of the intimal wall of the region of bifurcation of the carotid artery from 12-24 CT scans of the neck will be discussed

  16. A new, rare and distinctive species of Panorthoptera (Insecta, Archaeorthoptera from the Upper Carboniferous of Xiaheyan (Ningxia, China

    Directory of Open Access Journals (Sweden)

    J.-J. Gu

    2017-11-01

    Full Text Available The Xiaheyan locality is providing abundant material on one of the earliest insect faunas. The most common species are comparatively remote relatives of Orthoptera (grasshoppers, crickets and katydids, belonging to the Archaeorthoptera nec Panorthoptera (the latter including crown Orthoptera. We establish the genus Sinogerarus gen. nov. to accommodate a new, rare species, S. pectinatus spec. nov., which can be conclusively assigned to Panorthoptera. It therefore represents the second occurrence of the group at this locality. The new species displays a distinctive combination of character states, adding to the knowledge of a number of Upper Carboniferous Panorthoptera whose relationships are poorly understood.

  17. Distinct Circuits for Recovery of Eye Dominance and Acuity in Murine Amblyopia.

    Science.gov (United States)

    Stephany, Céleste-Élise; Ma, Xiaokuang; Dorton, Hilary M; Wu, Jie; Solomon, Alexander M; Frantz, Michael G; Qiu, Shenfeng; McGee, Aaron W

    2018-05-24

    Degrading vision by one eye during a developmental critical period yields enduring deficits in both eye dominance and visual acuity. A predominant model is that "reactivating" ocular dominance (OD) plasticity after the critical period is required to improve acuity in amblyopic adults. However, here we demonstrate that plasticity of eye dominance and acuity are independent and restricted by the nogo-66 receptor (ngr1) in distinct neuronal populations. Ngr1 mutant mice display greater excitatory synaptic input onto both inhibitory and excitatory neurons with restoration of normal vision. Deleting ngr1 in excitatory cortical neurons permits recovery of eye dominance but not acuity. Reciprocally, deleting ngr1 in thalamus is insufficient to rectify eye dominance but yields improvement of acuity to normal. Abolishing ngr1 expression in adult mice also promotes recovery of acuity. Together, these findings challenge the notion that mechanisms for OD plasticity contribute to the alterations in circuitry that restore acuity in amblyopia. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. A programmable display layer for virtual reality system architectures

    NARCIS (Netherlands)

    Smit, F.A.; Liere, van R.; Fröhlich, B.

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We

  19. DUMA - a program to display distributions in hexagonal geometry

    International Nuclear Information System (INIS)

    Tran Quoc Dung; Makai, M.

    1987-09-01

    DUMA program displays hexagonal structures applied in WWER-440 reactors or one or two distributions in them. It helps users to display either integer, literal or real arrays in an arbitrary hexagonal structure. Possible applications: displaying reactor core layout, power distribution or activity measurements. (author)

  20. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  1. Thermoluminescence emission spectrometry of glass display in mobile phones and resulting evaluation of the dosimetric properties of a specific type of display glass

    International Nuclear Information System (INIS)

    Discher, Michael; Woda, Clemens

    2014-01-01

    Glass displays of mobile phones are sensitive to ionizing radiation and can be used for retrospective dosimetry for the purpose of triage after a radiological accident or attack. In this study the two main types of glass display that are used in modern mobile phones were investigated using thermoluminescence (TL) emission spectrometry. A different TL spectrum was observed for the glass display of category A (lime-aluminosilicate glass) and category B (boron-silicate glass). Based on the spectral measurements an optimized detection window was chosen to re-evaluate the dosimetric properties (dose response, optical and long-term stability) of glass display category B. - Highlights: • Two display glass types show similar TL emission peaks but with strongly different relative intensities. • The intrinsic background TL signal peaks at similar wavelengths as the radiation induced signal. • Dosimetric properties of one display glass type were re-evaluated using an optimized detection window

  2. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays.

    Science.gov (United States)

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising.

  3. Latency requirements for head-worn display S/EVS applications

    Science.gov (United States)

    Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.

    2004-08-01

    NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  4. Looking forward: In-vehicle auxiliary display positioning affects carsickness.

    Science.gov (United States)

    Kuiper, Ouren X; Bos, Jelte E; Diels, Cyriel

    2018-04-01

    Carsickness is associated with a mismatch between actual and anticipated sensory signals. Occupants of automated vehicles, especially when using a display, are at higher risk of becoming carsick than drivers of conventional vehicles. This study aimed to evaluate the impact of positioning of in-vehicle displays, and subsequent available peripheral vision, on carsickness of passengers. We hypothesized that increased peripheral vision during display use would reduce carsickness. Seated in the front passenger seat 18 participants were driven a 15-min long slalom on two occasions while performing a continuous visual search-task. The display was positioned either at 1) eye-height in front of the windscreen, allowing peripheral view on the outside world, and 2) the height of the glove compartment, allowing only limited view on the outside world. Motion sickness was reported at 1-min intervals. Using a display at windscreen height resulted in less carsickness compared to a display at glove compartment height. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Nucleic acid secondary structure prediction and display.

    OpenAIRE

    Stüber, K

    1986-01-01

    A set of programs has been developed for the prediction and display of nucleic acid secondary structures. Information from experimental data can be used to restrict or enforce secondary structural elements. The predictions can be displayed either on normal line printers or on graphic devices like plotters or graphic terminals.

  6. Effect of display type and room illuminance in chest radiographs

    International Nuclear Information System (INIS)

    Liukkonen, Esa; Jartti, Airi; Haapea, Marianne; Oikarinen, Heljae; Ahvenjaervi, Lauri; Mattila, Seija; Nevala, Terhi; Palosaari, Kari; Perhomaa, Marja; Nieminen, Miika T.

    2016-01-01

    To compare diagnostic accuracy in the detection of subtle chest lesions on digital chest radiographs using medical-grade displays, consumer-grade displays, and tablet devices under bright and dim ambient light. Five experienced radiologists independently assessed 50 chest radiographs (32 with subtle pulmonary findings and 18 without apparent findings) under bright (510 lx) and dim (16 lx) ambient lighting. Computed tomography was used as the reference standard for interstitial and nodular lesions and follow-up chest radiograph for pneumothorax. Diagnostic accuracy and sensitivity were calculated for assessments carried out in all displays and compared using the McNemar test. The level of significance was set to p < 0.05. Significant differences in sensitivity between the assessments under bright and dim lighting were found among consumer-grade displays in interstitial opacities with, and in pneumothorax without, Digital Imaging and Communication in Medicine-Grayscale Standard Display Function (DICOM-GSDF) calibration. Compared to 6 megapixel (MP) display under bright lighting, sensitivity in pneumothorax was lower in the tablet device and the consumer-grade display. Sensitivity in interstitial opacities was lower in the DICOM-GSDF calibrated consumer-grade display. A consumer-grade display with or without DICOM-GSDF calibration or a tablet device is not suitable for reading digital chest radiographs in bright lighting. No significant differences were observed between five displays in dim light. (orig.)

  7. HOXA1 and TALE proteins display cross-regulatory interactions and form a combinatorial binding code on HOXA1 targets.

    Science.gov (United States)

    De Kumar, Bony; Parker, Hugo J; Paulson, Ariel; Parrish, Mark E; Pushel, Irina; Singh, Narendra Pratap; Zhang, Ying; Slaughter, Brian D; Unruh, Jay R; Florens, Laurence; Zeitlinger, Julia; Krumlauf, Robb

    2017-09-01

    Hoxa1 has diverse functional roles in differentiation and development. We identify and characterize properties of regions bound by HOXA1 on a genome-wide basis in differentiating mouse ES cells. HOXA1-bound regions are enriched for clusters of consensus binding motifs for HOX, PBX, and MEIS, and many display co-occupancy of PBX and MEIS. PBX and MEIS are members of the TALE family and genome-wide analysis of multiple TALE members (PBX, MEIS, TGIF, PREP1, and PREP2) shows that nearly all HOXA1 targets display occupancy of one or more TALE members. The combinatorial binding patterns of TALE proteins define distinct classes of HOXA1 targets, which may create functional diversity. Transgenic reporter assays in zebrafish confirm enhancer activities for many HOXA1-bound regions and the importance of HOX-PBX and TGIF motifs for their regulation. Proteomic analyses show that HOXA1 physically interacts on chromatin with PBX, MEIS, and PREP family members, but not with TGIF, suggesting that TGIF may have an independent input into HOXA1-bound regions. Therefore, TALE proteins appear to represent a wide repertoire of HOX cofactors, which may coregulate enhancers through distinct mechanisms. We also discover extensive auto- and cross-regulatory interactions among the Hoxa1 and TALE genes, indicating that the specificity of HOXA1 during development may be regulated though a complex cross-regulatory network of HOXA1 and TALE proteins. This study provides new insight into a regulatory network involving combinatorial interactions between HOXA1 and TALE proteins. © 2017 De Kumar et al.; Published by Cold Spring Harbor Laboratory Press.

  8. Anaphylactic Reactions After Discontinuation of Hymenoptera Venom Immunotherapy: A Clonal Mast Cell Disorder Should Be Suspected.

    Science.gov (United States)

    Bonadonna, Patrizia; Zanotti, Roberta; Pagani, Mauro; Bonifacio, Massimiliano; Scaffidi, Luigi; Olivieri, Elisa; Franchini, Maurizio; Reccardini, Federico; Costantino, Maria Teresa; Roncallo, Chiara; Mauro, Marina; Boni, Elisa; Rizzini, Fabio Lodi; Bilò, Maria Beatrice; Marcarelli, Anna Rosaria; Passalacqua, Giovanni

    2017-12-16

    Up to 75% of patients with severe anaphylactic reactions after Hymenoptera sting are at risk of further severe reactions if re-stung. Venom immunotherapy (VIT) is highly effective in protecting individuals with ascertained Hymenoptera venom allergy (HVA) and previous severe reactions. After a 3- to 5-year VIT course, most patients remain protected after VIT discontinuation. Otherwise, a lifelong treatment should be considered in high-risk patients (eg, in mastocytosis). Several case reports evidenced that patients with mastocytosis and HVA, although protected during VIT, can re-experience severe and sometimes fatal reactions after VIT discontinuation. To evaluate whether patients who lost protection after VIT discontinuation may suffer from clonal mast cell disorders. The survey describes the characteristics of patients who received a full course of VIT for previous severe reactions and who experienced another severe reaction at re-sting after VIT discontinuation. Those with a Red Española de Mastocitosis score of 2 or more or a serum basal tryptase level of more than 25 ng/mL underwent a hematological workup (bone marrow biopsy, KIT mutation, expression of aberrant CD25) and/or skin biopsy. Nineteen patients (mean age, 56.3 years; 89.5% males) were evaluated. All of them had received at least 4 years of VIT and were protected. After VIT discontinuation they were re-stung and developed, in all but 1 case, severe anaphylactic reactions (12 with loss of consciousness, in the absence of urticaria/angioedema). Eighteen patients (94.7%) had a clonal mast cell disorder, 8 of them with normal tryptase. Looking at this selected population, we suggest that mastocytosis should be considered in patients developing severe reactions at re-sting after VIT discontinuation and, as a speculation, patients with mastocytosis and HVA should be VIT-treated lifelong. Copyright © 2017. Published by Elsevier Inc.

  9. OZ: An Innovative Primary Flight Display, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed SBIR project will develop OZ, an innovative primary flight display for aircraft. The OZ display, designed from "first principles" of vision science,...

  10. A comparison of tracking with visual and kinesthetic-tactual displays

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.

    1981-01-01

    Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under appropriate conditions it may be an effective means of providing visual workload relief. In order to better understand how KT tracking differs from visual tracking, both a critical tracking task and stationary single-axis tracking tasks were conducted with and without velocity quickening. On the critical tracking task, the visual displays were superior; however, the KT quickened display was approximately equal to the visual unquickened display. Mean squared error scores in the stationary tracking tasks for the visual and KT displays were approximately equal in the quickened conditions, and the describing functions were very similar. In the unquickened conditions, the visual display was superior. Subjects using the unquickened KT display exhibited a low frequency lead-lag that may be related to sensory adaptation.

  11. A novel shape-changing haptic table-top display

    Science.gov (United States)

    Wang, Jiabin; Zhao, Lu; Liu, Yue; Wang, Yongtian; Cai, Yi

    2018-01-01

    A shape-changing table-top display with haptic feedback allows its users to perceive 3D visual and texture displays interactively. Since few existing devices are developed as accurate displays with regulatory haptic feedback, a novel attentive and immersive shape changing mechanical interface (SCMI) consisting of image processing unit and transformation unit was proposed in this paper. In order to support a precise 3D table-top display with an offset of less than 2 mm, a custommade mechanism was developed to form precise surface and regulate the feedback force. The proposed image processing unit was capable of extracting texture data from 2D picture for rendering shape-changing surface and realizing 3D modeling. The preliminary evaluation result proved the feasibility of the proposed system.

  12. [Microcomputer control of a LED stimulus display device].

    Science.gov (United States)

    Ohmoto, S; Kikuchi, T; Kumada, T

    1987-02-01

    A visual stimulus display system controlled by a microcomputer was constructed at low cost. The system consists of a LED stimulus display device, a microcomputer, two interface boards, a pointing device (a "mouse") and two kinds of software. The first software package is written in BASIC. Its functions are: to construct stimulus patterns using the mouse, to construct letter patterns (alphabet, digit, symbols and Japanese letters--kanji, hiragana, katakana), to modify the patterns, to store the patterns on a floppy disc, to translate the patterns into integer data which are used to display the patterns in the second software. The second software package, written in BASIC and machine language, controls display of a sequence of stimulus patterns in predetermined time schedules in visual experiments.

  13. Reciprocal Engagement Between a Scientist and Visual Displays

    Science.gov (United States)

    Nolasco, Michelle Maria

    In this study the focus of investigation was the reciprocal engagement between a professional scientist and the visual displays with which he interacted. Visual displays are considered inextricable from everyday scientific endeavors and their interpretation requires a "back-and-forthness" between the viewers and the objects being viewed. The query that drove this study was: How does a scientist engage with visual displays during the explanation of his understanding of extremely small biological objects? The conceptual framework was based in embodiment where the scientist's talk, gesture, and body position were observed and microanalyzed. The data consisted of open-ended interviews that positioned the scientist to interact with visual displays when he explained the structure and function of different sub-cellular features. Upon microanalyzing the scientist's talk, gesture, and body position during his interactions with two different visual displays, four themes were uncovered: Naming, Layering, Categorizing, and Scaling . Naming occurred when the scientist added markings to a pre-existing, hand-drawn visual display. The markings had meaning as stand-alone label and iconic symbols. Also, the markings transformed the pre-existing visual display, which resulted in its function as a new visual object. Layering occurred when the scientist gestured over images so that his gestures aligned with one or more of the image's features, but did not touch the actual visual display. Categorizing occurred when the scientist used contrasting categories, e.g. straight vs. not straight, to explain his understanding about different characteristics that the small biological objects held. Scaling occurred when the scientist used gesture to resize an image's features so that they fit his bodily scale. Three main points were drawn from this study. First, the scientist employed a variety of embodied strategies—coordinated talk, gesture, and body position—when he explained the structure

  14. Evaluation of technical design of advanced information display(II)

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae; Park, Hyun Jin

    2004-02-01

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal such as CRT. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices

  15. Evaluation of technical design of advanced information display(II)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae; Park, Hyun Jin [Kumoh National Univ., Gumi (Korea, Republic of)

    2004-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal such as CRT. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices.

  16. Large Display Interaction Using Mobile Devices

    OpenAIRE

    Bauer, Jens

    2015-01-01

    Large displays become more and more popular, due to dropping prices. Their size and high resolution leverages collaboration and they are capable of dis- playing even large datasets in one view. This becomes even more interesting as the number of big data applications increases. The increased screen size and other properties of large displays pose new challenges to the Human- Computer-Interaction with these screens. This includes issues such as limited scalability to the number of users, diver...

  17. Projection display technology for avionics applications

    Science.gov (United States)

    Kalmanash, Michael H.; Tompkins, Richard D.

    2000-08-01

    Avionics displays often require custom image sources tailored to demanding program needs. Flat panel devices are attractive for cockpit installations, however recent history has shown that it is not possible to sustain a business manufacturing custom flat panels in small volume specialty runs. As the number of suppliers willing to undertake this effort shrinks, avionics programs unable to utilize commercial-off-the-shelf (COTS) flat panels are placed in serious jeopardy. Rear projection technology offers a new paradigm, enabling compact systems to be tailored to specific platform needs while using a complement of COTS components. Projection displays enable improved performance, lower cost and shorter development cycles based on inter-program commonality and the wide use of commercial components. This paper reviews the promise and challenges of projection technology and provides an overview of Kaiser Electronics' efforts in developing advanced avionics displays using this approach.

  18. Distinctiveness of Saudi Arabian EFL Learners

    Directory of Open Access Journals (Sweden)

    Manssour Habbash

    2016-04-01

    Full Text Available In view of the increasing concern among English language teachers dealing with students from Saudi Arabia, as it manifests in TESOL community discussions, about the uniqueness of Saudi Arabian EFL learners, this paper attempts to document the outcome of a study of their distinctiveness from the perspective of expatriate teachers working for PYPs (Preparatory Year Programs in Saudi Arabia. This study examines the distinctiveness with regard to the learning attitudes of Saudi students that are often cultivated by the culture and academic environment in their homeland. Employing an emic approach for collecting the required data an analysis was carried out in light of the other studies on ‘education’ in Saudi Arabia that have particular reference to the factors that can positively influence student motivation, student success and the academic environment. The findings were used in constructing the rationale behind such distinctiveness. Assuming that the outcome of the discussion on the findings of this exploration can be helpful for teachers in adapting their teaching methodology and improving their teacher efficacy in dealing with students both from the kingdom and in the kingdom, some recommendations are made. Keywords: China Distinctiveness, Saudi Arabian University context, Expatriate teachers’ perspective, Distinctiveness Theory

  19. The human factors of CRT displays for nuclear power plant control

    International Nuclear Information System (INIS)

    Danchak, M.M.

    1984-01-01

    This chapter attempts to show how the Cathode Ray Tube (CRT) can be used to effectively present information to the operator rather than just data. The capabilities of the human as a sensing and information processing subsystem are discussed with CRT displays in mind. The display system is described in terms of its hardware and functioning. The interface between the two is examined by providing substantive guidelines for the effective design of CRT displays for nuclear power plant control. Alphanumeric displays, graphic displays, and representational displays are treated. The design of CRT displays for nuclear power plant control requires an extensive knowledge of cognitive psychology, computer display systems and the process being controlled

  20. Social conformity despite individual preferences for distinctiveness.

    Science.gov (United States)

    Smaldino, Paul E; Epstein, Joshua M

    2015-03-01

    We demonstrate that individual behaviours directed at the attainment of distinctiveness can in fact produce complete social conformity. We thus offer an unexpected generative mechanism for this central social phenomenon. Specifically, we establish that agents who have fixed needs to be distinct and adapt their positions to achieve distinctiveness goals, can nevertheless self-organize to a limiting state of absolute conformity. This seemingly paradoxical result is deduced formally from a small number of natural assumptions and is then explored at length computationally. Interesting departures from this conformity equilibrium are also possible, including divergence in positions. The effect of extremist minorities on these dynamics is discussed. A simple extension is then introduced, which allows the model to generate and maintain social diversity, including multimodal distinctiveness distributions. The paper contributes formal definitions, analytical deductions and counterintuitive findings to the literature on individual distinctiveness and social conformity.

  1. Experience with model based display for advanced diagnostics and control

    International Nuclear Information System (INIS)

    Staffon, J.D.; Lindsay, R.W.

    1989-01-01

    A full color, model based display system based on the Rankine thermodynamic cycle has been developed for use at the Experimental Breeder Reactor II by plant operators, engineers, and experimenters. The displays generate a real time thermodynamic model of the plant processes on computer screens to provide a direct indication of the plant performance. Operators and others who view the displays are no longer required to mentally ''construct'' a model of the process before acting. The model based display accurately depicts the plant states. It appears to effectively reduce the gulf of evaluation, which should result in a significant reduction in human operator errors if this plant display approach is adopted by the nuclear industry. Preliminary comments from users, including operators, indicate an overwhelming acceptance of the display approach. The displays incorporate alarm functions as well as levels of detail ''paging'' capability. The system is developed on a computer network which allows the easy addition of displays as well as extra computers. Constructing a complete console can be rapid and inexpensive. 1 ref., 2 figs

  2. The ARG1-LIKE2 gene of Arabidopsis functions in a gravity signal transduction pathway that is genetically distinct from the PGM pathway

    Science.gov (United States)

    Guan, Changhui; Rosen, Elizabeth S.; Boonsirichai, Kanokporn; Poff, Kenneth L.; Masson, Patrick H.

    2003-01-01

    The arl2 mutants of Arabidopsis display altered root and hypocotyl gravitropism, whereas their inflorescence stems are fully gravitropic. Interestingly, mutant roots respond like the wild type to phytohormones and an inhibitor of polar auxin transport. Also, their cap columella cells accumulate starch similarly to wild-type cells, and mutant hypocotyls display strong phototropic responses to lateral light stimulation. The ARL2 gene encodes a DnaJ-like protein similar to ARG1, another protein previously implicated in gravity signal transduction in Arabidopsis seedlings. ARL2 is expressed at low levels in all organs of seedlings and plants. arl2-1 arg1-2 double mutant roots display kinetics of gravitropism similar to those of single mutants. However, double mutants carrying both arl2-1 and pgm-1 (a mutation in the starch-biosynthetic gene PHOSPHOGLUCOMUTASE) at the homozygous state display a more pronounced root gravitropic defect than the single mutants. On the other hand, seedlings with a null mutation in ARL1, a paralog of ARG1 and ARL2, behave similarly to the wild type in gravitropism and other related assays. Taken together, the results suggest that ARG1 and ARL2 function in the same gravity signal transduction pathway in the hypocotyl and root of Arabidopsis seedlings, distinct from the pathway involving PGM.

  3. Operational characteristics of pediatric radiology: Image display stations

    International Nuclear Information System (INIS)

    Taira, R.K.

    1987-01-01

    The display of diagnostic images is accomplished in the UCLA Pediatric Radiology Clinical Radiology Imaging System (CRIS) using 3 different types of digital viewing stations. These include a low resolution station with six 512 x 512 monitors, a high resolution station with three 1024 x 1024 monitors, and a very high resolution workstation with two 2048 x 2048 monitors. The display stations provide very basic image processing manipulations including zoom and scroll, contrast enhancement, and contrast reversal. The display stations are driven by a computer system which is dedicated for clinical use. During times when the clinical computer is unavailable (maintenance or system malfunction), the 512 x 512 workstation can be switched to operate from a research PACS system in the UCLA Image Processing Laboratory via a broadband communication network. Our initial clinical implementation involves digital viewing for pediatric radiology conferences. Presentation of inpatient cases use the six monitor 512 x 512 multiple viewing station. Later stages of the clinical implementation involve the use of higher resolution displays for the purpose of primary diagnosis from video displays

  4. A Qualitative Method to Estimate HSI Display Complexity

    Energy Technology Data Exchange (ETDEWEB)

    Hugo, Jacques; Gertman, David [Idaho National Laboratory, Idaho (United States)

    2013-04-15

    There is mounting evidence that complex computer system displays in control rooms contribute to cognitive complexity and, thus, to the probability of human error. Research shows that reaction time increases and response accuracy decreases as the number of elements in the display screen increase. However, in terms of supporting the control room operator, approaches focusing on addressing display complexity solely in terms of information density and its location and patterning, will fall short of delivering a properly designed interface. This paper argues that information complexity and semantic complexity are mandatory components when considering display complexity and that the addition of these concepts assists in understanding and resolving differences between designers and the preferences and performance of operators. This paper concludes that a number of simplified methods, when combined, can be used to estimate the impact that a particular display may have on the operator's ability to perform a function accurately and effectively. We present a mixed qualitative and quantitative approach and a method for complexity estimation.

  5. Adaptive controller for volumetric display of neuroimaging studies

    Science.gov (United States)

    Bleiberg, Ben; Senseney, Justin; Caban, Jesus

    2014-03-01

    Volumetric display of medical images is an increasingly relevant method for examining an imaging acquisition as the prevalence of thin-slice imaging increases in clinical studies. Current mouse and keyboard implementations for volumetric control provide neither the sensitivity nor specificity required to manipulate a volumetric display for efficient reading in a clinical setting. Solutions to efficient volumetric manipulation provide more sensitivity by removing the binary nature of actions controlled by keyboard clicks, but specificity is lost because a single action may change display in several directions. When specificity is then further addressed by re-implementing hardware binary functions through the introduction of mode control, the result is a cumbersome interface that fails to achieve the revolutionary benefit required for adoption of a new technology. We address the specificity versus sensitivity problem of volumetric interfaces by providing adaptive positional awareness to the volumetric control device by manipulating communication between hardware driver and existing software methods for volumetric display of medical images. This creates a tethered effect for volumetric display, providing a smooth interface that improves on existing hardware approaches to volumetric scene manipulation.

  6. A comparison of visual and kinesthetic-tactual displays for compensatory tracking

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.

    1983-01-01

    Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under certain conditions it can be an effective alternative or supplement to visual displays. In order to understand better how KT tracking compares with visual tracking, both a critical tracking and stationary single-axis tracking tasks were conducted with and without velocity quickening. In the critical tracking task, the visual displays were superior, however, the quickened KT display was approximately equal to the unquickened visual display. In stationary tracking tasks, subjects adopted lag equalization with the quickened KT and visual displays, and mean-squared error scores were approximately equal. With the unquickened displays, subjects adopted lag-lead equalization, and the visual displays were superior. This superiority was partly due to the servomotor lag in the implementation of the KT display and partly due to modality differences.

  7. Display Rules for Anger and Aggression in School-Age Children.

    Science.gov (United States)

    Underwood, Marion K.; And Others

    1992-01-01

    Two studies examined the development of display rules for anger and the relationship between the use of display rules for anger and aggressiveness as rated by school peers. Findings indicate that the phenomenon of display rules for anger is complex and depends on the way display rules are defined and the age and gender of the subjects. (GLR)

  8. Investigation of Energy-Efficient Supermarket Display Cases

    Energy Technology Data Exchange (ETDEWEB)

    Walker, D.H.

    2005-01-21

    Supermarkets represent one of the largest energy-intensive building groups in the commercial sector, consuming 2 to 3 million kWh/yr per store (ES-1). Over half of this energy use is for the refrigeration of food display cases and storage coolers. Display cases are used throughout a supermarket for the merchandising of perishable food products. The cases are maintained at air temperatures ranging from -10 to 35 F, depending upon the type of product stored. The operating characteristics and energy requirements of the refrigeration system are directly related to the refrigeration load. The sources of the display case refrigeration load consist of: (1) Moist and warm air infiltration through the open front of the case--air curtains are employed to inhibit this infiltration, but some ambient air is entrained, which adds a substantial portion to the refrigeration load. (2) Heat conduction through case panels and walls. (3) Thermal radiation from the ambient to the product and display case interior. (4) Internal thermal loads--the use of lights, evaporator fans, periodic defrosts, and antisweat heaters adds to the refrigeration load of the display case as well as directly consuming electric energy. The impact of each of these elements on the refrigeration load is very dependent upon case type (Figure ES-1). For example, air infiltration is the most significant portion of the refrigeration load for open, multi-deck cases, while radiation is the largest part of the load for tub-type cases. The door anti-sweat heaters represent a major share of the refrigeration load for frozen food door reach-in cases. Figure ES-2 shows the distribution of display cases in a typical supermarket (ES-2). Open, multi-deck, medium temperature display cases typically comprise about half of the refrigerated fixtures in a store (ES-3). In addition, medium temperature fixtures and storage coolers account for roughly 70 to 75 percent of the total store refrigeration load with open, multi-deck cases

  9. Three-dimensional display techniques: description and critique of methods

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1982-01-01

    The recent advances in non invasive medical imaging of 3 dimensional spatial distribution of radionuclides, X-ray attenuation coefficients, and nuclear magnetic resonance parameters necessitate development of a general method for displaying these data. The objective of this paper is to give a systematic description and comparison of known methods for displaying three dimensional data. The discussion of display methods is divided into two major categories: 1) computer-graphics methods which use a two dimensional display screen; and 2) optical methods (such as holography, stereopsis and vari-focal systems)

  10. Multichannel waveform display system

    International Nuclear Information System (INIS)

    Kolvankar, V.G.

    1989-01-01

    For any multichannel data acquisition system, a multichannel paper chart recorder undoubtedly forms an essential part of the system. When deployed on-line, it instantaneously provides, for visual inspection, hard copies of the signal waveforms on common time base at any desired sensitivity and time resolution. Within the country, only a small range of these strip chart recorder s is available, and under stringent specifications imported recorders are often procured. The cost of such recorders may range from 1 to 5 lakhs of rupees in foreign exchange. A system to provide on the oscilloscope a steady display of multichannel waveforms, refreshed from the digital data stored in the memory is developed. The merits and demerits of the display system are compared with that built around a conventional paper chart recorder. Various illustrations of multichannel seismic event data acquired at Gauribidanur seismic array station are also presented. (author). 2 figs

  11. Visual distinctiveness can enhance recency effects.

    Science.gov (United States)

    Bornstein, B H; Neely, C B; LeCompte, D C

    1995-05-01

    Experimental efforts to meliorate the modality effect have included attempts to make the visual stimulus more distinctive. McDowd and Madigan (1991) failed to find an enhanced recency effect in serial recall when the last item was made more distinct in terms of its color. In an attempt to extend this finding, three experiments were conducted in which visual distinctiveness was manipulated in a different manner, by combining the dimensions of physical size and coloration (i.e., whether the stimuli were solid or outlined in relief). Contrary to previous findings, recency was enhanced when the size and coloration of the last item differed from the other items in the list, regardless of whether the "distinctive" item was larger or smaller than the remaining items. The findings are considered in light of other research that has failed to obtain a similar enhanced recency effect, and their implications for current theories of the modality effect are discussed.

  12. Heterologous surface display on lactic acid bacteria: non-GMO alternative?

    Science.gov (United States)

    Zadravec, Petra; Štrukelj, Borut; Berlec, Aleš

    2015-01-01

    Lactic acid bacteria (LAB) are food-grade hosts for surface display with potential applications in food and therapy. Alternative approaches to surface display on LAB would avoid the use of recombinant DNA technology and genetically-modified organism (GMO)-related regulatory requirements. Non-covalent surface display of proteins can be achieved by fusing them to various cell-wall binding domains, of which the Lysine motif domain (LysM) is particularly well studied. Fusion proteins have been isolated from recombinant bacteria or from their growth medium and displayed on unmodified bacteria, enabling heterologous surface display. This was demonstrated on non-viable cells devoid of protein content, termed bacteria-like particles, and on various species of genus Lactobacillus. Of the latter, Lactobacillus salivarius ATCC 11741 was recently shown to be particularly amenable for LysM-mediated display. Possible regulatory implications of heterologous surface display are discussed, particularly those relevant for the European Union.

  13. 72-directional display having VGA resolution for high-appearance image generation

    Science.gov (United States)

    Takaki, Yasuhiro; Dairiki, Takeshi

    2006-02-01

    The high-density directional display, which was originally developed in order to realize a natural 3D display, is not only a 3D display but also a high-appearance display. The appearances of objects, such as glare and transparency, are the results of the reflection and the refraction of rays. The faithful reproduction of such appearances of objects is impossible using conventional 2D displays because rays diffuse on the display screen. The high-density directional display precisely controls the horizontal ray directions so that it can reproduce the appearances of objects. The fidelity of the reproduction of object appearances depends on the ray angle sampling pitch. The angle sampling pitch is determined by considering the human eye imaging system. In the present study the high-appearance display which has the resolution of 640×400 and emits rays in 72 different horizontal directions with the angle pitch of 0.38° was constructed. Two 72-directional displays were combined, each of which consisted of a high-resolution LCD panel (3,840×2,400) and a slanted lenticular sheet. Two images produced by two displays were superimposed by a half mirror. A slit array was placed at the focal plane of the lenticular sheet for each display to reduce the horizontal image crosstalk in the combined image. The impression analysis shows that the high-appearance display provides higher appearances and presence than the conventional 2D displays do.

  14. Time-Sequential Working Wavelength-Selective Filter for Flat Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    René de la Barré

    2017-02-01

    Full Text Available A time-sequential working, spatially-multiplexed autostereoscopic 3D display design consisting of a fast switchable RGB-color filter array and a fast color display is presented. The newly-introduced 3D display design is usable as a multi-user display, as well as a single-user system. The wavelength-selective filter barrier emits the light from a larger aperture than common autostereoscopic barrier displays with similar barrier pitch and ascent. Measurements on a demonstrator with commercial display components, simulations and computational evaluations have been carried out to describe the proposed wavelength-selective display design in static states and to show the weak spots of display filters in commercial displays. An optical modelling of wavelength-selective barriers has been used for instance to calculate the light ray distribution properties of that arrangement. In the time-sequential implementation, it is important to avoid that quick eye or eyelid movement leads to visible color artifacts. Therefore, color filter cells, switching faster than conventional LC display cells, must distribute directed light from different primaries at the same time, to create a 3D presentation. For that, electric tunable liquid crystal Fabry–Pérot color filters are presented. They switch on-off the colors red, green and blue in the millisecond regime. Their active areas consist of a sub-micrometer-thick nematic layer sandwiched between dielectric mirrors and indium tin oxide (ITO-electrodes. These cells shall switch narrowband light of red, green or blue. A barrier filter array for a high resolution, glasses-free 3D display has to be equipped with several thousand switchable filter elements having different color apertures.

  15. Flatbed-type 3D display systems using integral imaging method

    Science.gov (United States)

    Hirayama, Yuzo; Nagatani, Hiroyuki; Saishu, Tatsuo; Fukushima, Rieko; Taira, Kazuki

    2006-10-01

    We have developed prototypes of flatbed-type autostereoscopic display systems using one-dimensional integral imaging method. The integral imaging system reproduces light beams similar of those produced by a real object. Our display architecture is suitable for flatbed configurations because it has a large margin for viewing distance and angle and has continuous motion parallax. We have applied our technology to 15.4-inch displays. We realized horizontal resolution of 480 with 12 parallaxes due to adoption of mosaic pixel arrangement of the display panel. It allows viewers to see high quality autostereoscopic images. Viewing the display from angle allows the viewer to experience 3-D images that stand out several centimeters from the surface of the display. Mixed reality of virtual 3-D objects and real objects are also realized on a flatbed display. In seeking reproduction of natural 3-D images on the flatbed display, we developed proprietary software. The fast playback of the CG movie contents and real-time interaction are realized with the aid of a graphics card. Realization of the safety 3-D images to the human beings is very important. Therefore, we have measured the effects on the visual function and evaluated the biological effects. For example, the accommodation and convergence were measured at the same time. The various biological effects are also measured before and after the task of watching 3-D images. We have found that our displays show better results than those to a conventional stereoscopic display. The new technology opens up new areas of application for 3-D displays, including arcade games, e-learning, simulations of buildings and landscapes, and even 3-D menus in restaurants.

  16. Effect of price display on brand luxury perceptions

    OpenAIRE

    Parguel , Béatrice; Delécolle , Thierry; Valette-Florence , Pierre

    2014-01-01

    Based on two experimental studies, this paper investigates the impact of price display in the luxury sector on perceived brand luxury and brand attitude. Using a sample of students, Study1 shows that price display is associated with higher perceived quality, uniqueness, and conspicuousness for a fictitious luxury brand presented in a store window. Using two real luxury brands and a larger sample of consumers, Study 2 confirms the positive effect of price display on the brand’s perceived consp...

  17. Flat panel planar optic display. Revision 4/95

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-05-01

    A prototype 10 inch flat panel Planar Optic display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic glass sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  18. Orthoscopic real-image display of digital holograms.

    Science.gov (United States)

    Makowski, P L; Kozacki, T; Zaperty, W

    2017-10-01

    We present a practical solution for the long-standing problem of depth inversion in real-image holographic display of digital holograms. It relies on a field lens inserted in front of the spatial light modulator device addressed by a properly processed hologram. The processing algorithm accounts for pixel size and wavelength mismatch between capture and display devices in a way that prevents image deformation. Complete images of large dimensions are observable from one position with a naked eye. We demonstrate the method experimentally on a 10-cm-long 3D object using a single full-HD spatial light modulator, but it can supplement most holographic displays designed to form a real image, including circular wide angle configurations.

  19. Student displays of academic competence in the international university

    DEFF Research Database (Denmark)

    Kristiansen, Elisabeth Dalby

    that there may be a connection, on the one hand between students'​ orientation to language as a relevant ressource for displaying academic competence and the project report as the sole product of the students'​ project, and on the other hand between the orientation to multimodal resources for displaying academic......The study presents an ethnomethodologically founded understanding of academic competence as situated social practices displayed in and through social interaction. The project uses Conversation Analysis as a method for describing such displays of competence. The project describes the conversational...... phenomenon of the 'Writing aloud Voice'​ (WAV) and describes how students use WAV sequences to demonstrate their knowledge of and ability to use certain academic conventions for formulating research questions. This constitutes one method for displaying academic competence. The project also describes...

  20. Analysis of Display Latency for 3D Perceptual Experiments

    Science.gov (United States)

    2016-11-01

    Stereoscopic images were displayed on an LG 55 in. Class (54.6 in. diagonal) cinema 3D 1080p 240 Hz LED TV for stimulus display. The 3D display...were nearly identical to those in Recording 3, where we had the variation in stimulus depth and the randomly sampled ISI times. The camera position

  1. Pins and posters: Paradigms for content publication on situated displays.

    Science.gov (United States)

    José, Rui; Pinto, Hélder; Silva, Bruno; Melro, Ana

    2013-01-01

    Public-display systems are still far from being a medium for meeting people's diverse communication goals. Moving toward open displays will require publication paradigms that can overcome the challenges of meaningful engagement and enable users to fully understand and control the publication process. The metaphors of pins and posters have inspired two complementary paradigms for public displays. Researchers implemented these paradigms in the Instant Places system, which they deployed on 10 displays in diverse urban locations for six months. They collected user and system data regarding the users' practices. The findings improve the understanding of what might drive user-generated content in networks of urban displays. Such knowledge can inform the design of tools and procedures for situated publication in public displays.

  2. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays

    Directory of Open Access Journals (Sweden)

    Francisco Martinez-Pabon

    2015-01-01

    Full Text Available A new generation of public displays demands high interactive and multiscreen features to enrich people’s experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising.

  3. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays

    Science.gov (United States)

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising. PMID:25950018

  4. A análise geométrica de questionários : a lição de La Distinction de Bourdieu

    Directory of Open Access Journals (Sweden)

    Henry Rouanet

    2005-01-01

    Full Text Available This paper investigates the use of Correspondence Analysis (CA in Bourdieu's La Distinction (1976/79, having in mind the sociologists who wish to analyze their data in a way in harmony with that of Bourdieu. For Bourdieu, CA is not simply a handy tool among others for visualizing data, but a unique instrument apt to uncover the two related spaces of individuals and of properties. A careful reading of La Distinction reveals a thoughtful and creative use of CA, applied to Individuals x Properties tables, with its main aids to interpretation. The major conclusions from this ``lesson'' remain valid today and generally apply to Individuals x Properties tables whether analyzed by CA or more specifically by Multiple Correspondence Analysis (MCA. In the analysis of questionnaires, doing correspondence analyses is not enough to do ``analyses à la Bourdieu''. The fundamental space must be constructed from a set of relevant variables ample enough to allow the full multidimensional display of individuals.

  5. Super long viewing distance light homogeneous emitting three-dimensional display

    Science.gov (United States)

    Liao, Hongen

    2015-04-01

    Three-dimensional (3D) display technology has continuously been attracting public attention with the progress in today's 3D television and mature display technologies. The primary characteristics of conventional glasses-free autostereoscopic displays, such as spatial resolution, image depths, and viewing angle, are often limited due to the use of optical lenses or optical gratings. We present a 3D display using MEMS-scanning-mechanism-based light homogeneous emitting (LHE) approach and demonstrate that the display can directly generate an autostereoscopic 3D image without the need for optical lenses or gratings. The generated 3D image has the advantages of non-aberration and a high-definition spatial resolution, making it the first to exhibit animated 3D images with image depth of six meters. Our LHE 3D display approach can be used to generate a natural flat-panel 3D display with super long viewing distance and alternative real-time image update.

  6. On Hobbes’s distinction of accidents

    Directory of Open Access Journals (Sweden)

    Lupoli Agostino

    2012-06-01

    Full Text Available An interpolation introduced by K. Schuhmann in his critical edition of "De corpore" (chap. VI, § 13 diametrically overturns the meaning of Hobbes’s doctrine of distinction of accidents in comparison with all previous editions. The article focuses on the complexity of this crucial juncture in "De corpore" argument on which depends the interpretation of Hobbes’s whole conception of science. It discusses the reasons pro and contra Schuhmann’s interpolation and concludes against it, because it is not compatible with the rationale underlying the complex architecture of "De corpore", which involves a symmetry between the ‘logical’ distinction of accidents and the ‘metaphysical’ distinction of phantasms.

  7. Emotional display rules and emotional labor: the moderating role of commitment.

    Science.gov (United States)

    Gosserand, Robin H; Diefendorff, James M

    2005-11-01

    The authors examined whether commitment to emotional display rules is a necessary condition for emotional display rules to affect behavior at work. Results using structural equation modeling revealed that display rule commitment moderated the relationships of emotional display rule perceptions with surface acting, deep acting, and positive affective delivery at work, such that the relationships were strong and positive when commitment to display rules was high and weak when commitment to display rules was low. These findings suggest that motivation plays a role in the emotional labor process in that individuals must be committed to display rules for these rules to affect behavior. ((c) 2005 APA, all rights reserved).

  8. Smart displays in intelligent environments: a vision for Europe 2007+

    Science.gov (United States)

    Maiser, Eric

    2005-07-01

    Future electronic systems will create "ambient intelligence": environments that recognise us, applications which can be used intuitively. Displays will always be a key part of such systems, because visual information provides a densely packed fast link to our brain. European researchers and suppliers are global drivers in display innovation - on the other hand Europe is a major influence on the market for display applications. However, today displays are produced in Asia, European research and development is scattered, and lacks both collaboration and a strong production base. That is why adria, a European network for the displays community, has been formed: Its goal is to substantially enhance the standing of the displays industry in Europe by creating a common knowledge base, by generating a common vision for a display future in Europe and by establishing appreciated services for a future association that will serve as a "one-stop-shop" for the community. To effectively start the discussion, a vision paper1 has been compiled including inputs from 95 individuals from 17 European countries. It describes the state displays research and industry are in today and estimates future developments displays will take towards intelligent systems in the next decade and beyond. Recommendations are made to reinforce the displays industry in a sustainable way building on existing strengths in research, as well as in the materials and equipment sectors. The adria network, its roadmapping approach as well as key projections and findings of the vision paper are described here, going beyond the topic of Organic Light Emitting Diodes alone.

  9. Versatile microbial surface-display for environmental remediation and biofuels production

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Cindy H.; Mulchandani, Ashok; Chen, wilfred

    2008-02-14

    Surface display is a powerful technique that utilizes natural microbial functional components to express proteins or peptides on the cell exterior. Since the reporting of the first surface-display system in the mid-1980s, a variety of new systems have been reported for yeast, Gram-positive and Gram-negative bacteria. Non-conventional display methods are emerging, eliminating the generation of genetically modified microorganisms. Cells with surface display are used as biocatalysts, biosorbents and biostimulants. Microbial cell-surface display has proven to be extremely important for numerous applications ranging from combinatorial library screening and protein engineering to bioremediation and biofuels production.

  10. An IBM-Compatible 640 X 200 Electroluminescent (EL) Display Monitor

    Science.gov (United States)

    Gullick, Paul; Schmachtenberg, Richard; Laakso, Carl

    1986-05-01

    An electroluminescent flat-panel display has been developed and recently introduced that fills any of the needs of the portable computer market. The display is very thin, yet rugged enough for the rigors of portability. It is highly integrated, and very reliable. It has the crisp and clear display image that is typical of high quality electroluminescent displays. The unit has a pixel matrix organization and pixel dimensions that are not only asthetically and ergonomically pleasing, but also make the display compatible with the most widely used software packages run on today's personal computers (Figure 1).

  11. Pester power: snackfoods displayed at supermarket checkouts in Melbourne, Australia.

    Science.gov (United States)

    Dixon, Helen; Scully, Maree; Parkinson, Kristiina

    2006-08-01

    To establish the amount and accessibility of snack food displayed at supermarket checkouts located in Melbourne, Australia. Observational survey of 24 randomly selected supermarkets situated within a 20-kilometre radius of Melbourne's General Post Office. Individual checkouts within each store (n=257) were observed to determine the types of items that were displayed, how they were promoted, and whether they were within the reach of children. All supermarkets surveyed displayed food products at their checkouts, with most checkouts displaying chocolate (87%), gum (81%) and sweets (80%). Only 7% of checkouts had their display of foods or drinks out of the reach of children. Foods displayed at supermarket checkouts in Melbourne are predominantly energy-dense confectionery items. They are often promoted in a way that targets children and encourages parents to impulse buy for their children.

  12. GROPE-1: a computer display to the sense of feel

    Energy Technology Data Exchange (ETDEWEB)

    Batter, J J; Brooks, Jr, F P

    1972-01-01

    A computer display system was built and programmed that exerts programmable forces on the fingers as one moves a knob in a plane. The system includes a movable carriage, position sensors, mechanisms for converting computer outputs to forces, a visual graphic display, and, most important, the programs. A controlled experiment measured the utility of force output. Two groups were taught topics in elementary field theory and exercised with the computer displays. One group had force displayed to the hand as well as to the eye. The other had visual display only. The experiment was repeated with three different sets of students. The force-display groups performed significantly better in two of the three cases; in the third case, interest in the subject was low and this seems to account for low performance.

  13. Reconfigurable Auditory-Visual Display

    Science.gov (United States)

    Begault, Durand R. (Inventor); Anderson, Mark R. (Inventor); McClain, Bryan (Inventor); Miller, Joel D. (Inventor)

    2008-01-01

    System and method for visual and audible communication between a central operator and N mobile communicators (N greater than or equal to 2), including an operator transceiver and interface, configured to receive and display, for the operator, visually perceptible and audibly perceptible signals from each of the mobile communicators. The interface (1) presents an audible signal from each communicator as if the audible signal is received from a different location relative to the operator and (2) allows the operator to select, to assign priority to, and to display, the visual signals and the audible signals received from a specified communicator. Each communicator has an associated signal transmitter that is configured to transmit at least one of the visual signals and the audio signal associated with the communicator, where at least one of the signal transmitters includes at least one sensor that senses and transmits a sensor value representing a selected environmental or physiological parameter associated with the communicator.

  14. Interactive computer graphics displays for hierarchical data structures

    International Nuclear Information System (INIS)

    Cahn, D.F.; Murano, C.V.

    1980-05-01

    An interactive computer graphical display program was developed as an aid to user visualization and manipulation of hierarchically structured data systems such as thesauri. In the present configuration, a thesaurus term and its primary and secondary conceptual neighbors are presented to the user in tree graph form on a CRT; the user then designates, via light pen or keyboard, any of the neighbors as the next term of interest and receives a new display centered on this term. By successive specification of broader, narrower, and related terms, the user can course rapidly through the thesaurus space and refine his search file. At any stage, he deals with a term-centered, conceptually meaningful picture of a localized portion of the thesaurus, and is freed from the artificial difficulties of handling the traditional alphabetized thesaurus. Intentional limitation of the associative range of each display frame, and the use of color, case, and interconnecting vectors to encode relationships among terms, enhance interpretability of the display. Facile movement through the term space, provided by interactive computation, allows the display to remain simple, and is an essential element of the system. 3 figures

  15. Evaluation of technical design of advanced information display

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae [Kumoh National Institute of Technology, Gumi (Korea, Republic of)

    2003-03-15

    The performance of human machine system such as nuclear power plant is highly dependent on the suitability of the interface design of the system. As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on CRT or CBP (Computer Based Procedure). This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues as much as possible. The design Issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices.

  16. Evaluation of technical design of advanced information display

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae

    2003-03-01

    The performance of human machine system such as nuclear power plant is highly dependent on the suitability of the interface design of the system. As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on CRT or CBP (Computer Based Procedure). This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues as much as possible. The design Issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices

  17. Instrumentation for on-line mountain range displays

    International Nuclear Information System (INIS)

    van Asselt, W.K.; Ahrens, L.A.

    1994-01-01

    A method to obtain and process 'mountain range' displays of beam signals is described. A custom-made trigger generator and a digital oscilloscope are used for the data acquisition and the graphical interface package LabVIEW is used to process the data. High resolution displays of wall monitor signals updating every AGS cycle have proven very powerful as a beam diagnostic

  18. Advanced display concepts in nuclear control rooms

    International Nuclear Information System (INIS)

    Clark, M.T.; Banks, W.W.; Blackman, H.S.; Gertman, D.I.

    1982-01-01

    Precursors necessary for the development of a full-scale predictor display/control system have been under development since the mid 1940's. The predictor display itself has been available for use in manual control systems since 1958. However, the nuclear industry has not yet explored the uses and benefits of predictor systems. The purpose of this paper is to provide information on the application of this technology to the nuclear industry. The possibility of employing a simulation-based control system for nuclear plant systems that currently use conventional auto/manual schemes is discussed. By employing simulation-based systems, a predictor display could be made available to the operator during manual operations, thus facilitating control without outwardly affecting the overall control scheme

  19. Secondary visual workload capability with primary visual and kinesthetic-tactual displays

    Science.gov (United States)

    Gilson, R. D.; Burke, M. W.; Jagacinski, R. J.

    1978-01-01

    Subjects performed a cross-adaptive tracking task with a visual secondary display and either a visual or a quickened kinesthetic-tactual (K-T) primary display. The quickened K-T display resulted in superior secondary task performance. Comparisons of secondary workload capability with integrated and separated visual displays indicated that the superiority of the quickened K-T display was not simply due to the elimination of visual scanning. When subjects did not have to perform a secondary task, there was no significant difference between visual and quickened K-T displays in performing a critical tracking task.

  20. Issues in symbol design for electronic displays of navigation information

    Science.gov (United States)

    2004-10-24

    An increasing number of electronic displays, ranging from small hand-held displays for general aviation to installed displays for air transport, are showing navigation information, such as symbols representing navigational aids. The wide range of dis...

  1. Performance analysis of multi-primary color display based on OLEDs/PLEDs

    Science.gov (United States)

    Xiong, Yan; Deng, Fei; Xu, Shan; Gao, Shufang

    2017-09-01

    A multi-primary color display, such as the six-primary color format, is a solution in expanding the color gamut of a full-color flat panel display. The performance of a multi-primary color display based on organic/polymer light-emitting diodes was analyzed in this study using the fitting curves of the characteristics of devices (i.e., current density, voltage, luminance). A white emitter was introduced into a six-primary color format to form a seven-primary color format that contributes to energy saving, and the ratio of power efficiency of a seven-primary color display to that of a six-primary color display would increase from 1.027 to 1.061 by using emitting diodes with different electroluminescent efficiencies. Different color matching schemes of the seven-primary color format display were compared in a uniform color space, and the scheme of the color reproduction did not significantly affect the display performance. Although seven- and six-primary color format displays benefit a full-color display with higher quality, they are less efficient than three-primary (i.e., red (R), green (G), and blue (B), RGB) and four-primary (i.e., RGB+white, RGBW) color format displays. For the seven-primary color formats considered in this study, the advantages of white-primary-added display with efficiently developed light-emitting devices were more evident than the format without a white primary.

  2. Strategy-oriented display concept to assist severe accident management

    International Nuclear Information System (INIS)

    Jeong, Kwangsub; Ha, Jaejoo

    2000-01-01

    The Critical Function Monitoring System (CFMS) is a typical Safety Parameter Display System (SPDS) to assist the operation of Korean Standard Nuclear Power Plants during normal and emergency operation, and SPDS for severe accident is being developed in Korea. When the existing CFMS is used under a severe accident situation, some problems are expected from: (1) different design basis, i.e. prevention of core melt vs. protection of radiation release to environment, (2) different parameters for decision-making, and (3) different domain and depth of information to restore the plant. To resolve the above problems, a concept, 'Strategy-Oriented Information Display' concept, for displaying information for severe accident management is developed in this paper. Whereas the existing SPDS structure is based on the critical safety function, the developed concept is based on the severe accident management strategy. The display for each strategy includes the plant parameters to check the status of plant and component with the logical or graphical views necessary for executing the strategy. As the application of the proposed concept, KAERI is developing a display system, the prototype severe accident SPDS, Severe Accident Management Display System (SAMDIS), to assist plant personnel for executing Korean Severe Accident Management Guidelines. CFMS is developed for a general display suitable to all situations with various displays. On the contrary, SAMDIS provides all the relevant information on one screen based on the proposed concept. The SAMDIS screen shows more extensive area than CFMS and thus plant personnel can recognize the overall plant status at a glance. This concept is quite effective when used with severe accident management guidelines because of the relatively macroscopic characteristics of a severe accident management strategy. (author)

  3. Electro Spray Method for Flexible Display

    Science.gov (United States)

    2016-05-12

    AFRL-AFOSR-JP-TR-2016-0095 Electro Spray Method for Flexible Display Yukiharu Uraoka NARA INSTITUTE OF SCIENCE AND TECHNOLOGY Final Report 11/26/2016...DATES COVERED (From - To)  20 Mar 2013 to 19 May 2016 4. TITLE AND SUBTITLE Electro Spray Method for Flexible Display 5a.  CONTRACT NUMBER 5b.  GRANT...NUMBER FA2386-13-1-4024 5c.  PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S) Yukiharu Uraoka 5d.  PROJECT NUMBER 5e.  TASK NUMBER 5f.   WORK UNIT NUMBER 7

  4. Paradigm for expert display systems in nuclear plant and elsewhere

    International Nuclear Information System (INIS)

    Gabriel, J.R.

    1986-02-01

    Display of relevant data concerning plant operation has been a concern of the nuclear industry from its beginnings. Since the incident at Three Mile Island, this matter has had much careful scrutiny. L. Beltracchi, in particular, has originated a sequence of important steps to improve the operator's ability to recognize plant states and their changes. In the early 1980's, Beltracchi (1983, 1984) proposed a display based on the Rankine cycle for light water reactors. More recently, in an unpublished work (1986b), he described an extension that includes a small, rule-based system in the display program, drawing inferences about plant operation from sensor readings, and displaying those inferences on the Rankine display. Our paper examines Beltracchi's rule-based display from the perspective of knowledge bases. Earlier (Gabriel, 1983) we noted that analytical models of system behavior are just as much a knowledge base as are the rules of a conventional expert system. The problem of finding useful displays for a complex plant is discussed from this perspective. We then present a paradigm for developing designs with properties similar to those in Beltracchi's Rankine cycle display. Finally, to clarify the issue, we give a small example from an imaginary plant

  5. Is eye damage caused by stereoscopic displays?

    Science.gov (United States)

    Mayer, Udo; Neumann, Markus D.; Kubbat, Wolfgang; Landau, Kurt

    2000-05-01

    A normal developing child will achieve emmetropia in youth and maintain it. Thereby cornea, lens and axial length of the eye grow astonishingly coordinated. In the last years research has evidenced that this coordinated growing process is a visually controlled closed loop. The mechanism has been studied particularly in animals. It was found that the growth of the axial length of the eyeball is controlled by image focus information from the retina. It was shown that maladjustment can occur by this visually-guided growth control mechanism that result in ametropia. Thereby it has been proven that e.g. short-sightedness is not only caused by heredity, but is acquired under certain visual conditions. It is shown that these conditions are similar to the conditions of viewing stereoscopic displays where the normal accommodation convergence coupling is disjoint. An evaluation is given of the potential of damaging the eyes by viewing stereoscopic displays. Concerning this, different viewing methods for stereoscopic displays are evaluated. Moreover, clues are given how the environment and display conditions shall be set and what users shall be chosen to minimize the risk of eye damages.

  6. An expert display system and nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Beltracchi, L.

    1988-01-01

    An expert display system controls automatically the display of segments on a cathode ray tube's screen to form an image of plant operations. The image consists of an icon of: 1) the process (heat engine cycle), 2) plant control systems, and 3) safety systems. A set of data-driven, forward-chaining computer stored rules control the display of segments. As plant operation changes, measured plant data are processed through the rules, and the results control the deletion and addition of segments to the display format. The icon contains information needed by control rooms operators to monitor plant operations. One example of an expert display is illustrated for the operator's task of monitoring leakage from a safety valve in a steam line of a boiling water reactor (BWR). In another example, the use of an expert display to monitor plant operations during pre-trip, trip, and post-trip operations is discussed as a universal display. The viewpoints and opinions expressed herein are the author's personal ones, and they are not to be interpreted as Nuclear Regulatory Commission criteria, requirements, or guidelines

  7. A task-based usage strategy for control centre wall displays

    International Nuclear Information System (INIS)

    Davey, E.

    2005-01-01

    This paper summarizes the findings from an exploratory definition of a usage strategy for multiple control centre wall displays in CANDU nuclear power plants. Wall displays are defined as large sized, vertically oriented display surfaces that may be positioned in various locations about a control room to support user information needs. The paper begins by discussing the need for a usage strategy for all control room information resources, and then reviews the history in wall display implementation and usage in nuclear power plant control rooms. The balance of the paper discusses the approach used in characterization and review of control room task information needs and definition of a wall display usage strategy. The paper concludes by outlining some of the possible impacts on future control room design and operations that the introduction of wall displays may imply. (author)

  8. Binding of the cSH3 domain of Grb2 adaptor to two distinct RXXK motifs within Gab1 docker employs differential mechanisms.

    Science.gov (United States)

    McDonald, Caleb B; Seldeen, Kenneth L; Deegan, Brian J; Bhat, Vikas; Farooq, Amjad

    2011-01-01

    A ubiquitous component of cellular signaling machinery, Gab1 docker plays a pivotal role in routing extracellular information in the form of growth factors and cytokines to downstream targets such as transcription factors within the nucleus. Here, using isothermal titration calorimetry (ITC) in combination with macromolecular modeling (MM), we show that although Gab1 contains four distinct RXXK motifs, designated G1, G2, G3, and G4, only G1 and G2 motifs bind to the cSH3 domain of Grb2 adaptor and do so with distinct mechanisms. Thus, while the G1 motif strictly requires the PPRPPKP consensus sequence for high-affinity binding to the cSH3 domain, the G2 motif displays preference for the PXVXRXLKPXR consensus. Such sequential differences in the binding of G1 and G2 motifs arise from their ability to adopt distinct polyproline type II (PPII)- and 3(10) -helical conformations upon binding to the cSH3 domain, respectively. Collectively, our study provides detailed biophysical insights into a key protein-protein interaction involved in a diverse array of signaling cascades central to health and disease. Copyright © 2010 John Wiley & Sons, Ltd.

  9. Experiments using electronic display information in the NASA terminal configured vehicle

    Science.gov (United States)

    Morello, S. A.

    1980-01-01

    The results of research experiments concerning pilot display information requirements and visualization techniques for electronic display systems are presented. Topics deal with display related piloting tasks in flight controls for approach-to-landing, flight management for the descent from cruise, and flight operational procedures considering the display of surrounding air traffic. Planned research of advanced integrated display formats for primary flight control throughout the various phases of flight is also discussed.

  10. Software Development for Remote Control and Firing Room Displays

    Science.gov (United States)

    Zambrano Pena, Jessica

    2014-01-01

    The Launch Control System (LCS) developed at NASA's Kennedy Space Center (KSC) will be used to launch future spacecraft. Two of the many components of this system are the Application Control Language (ACL) and remote displays. ACL is a high level domain specific language that is used to write remote control applications for LCS. Remote displays are graphical user interfaces (GUIs) developed to display vehicle and Ground Support Equipment (GSE) data, they also provide the ability to send commands to control GSE and the vehicle. The remote displays and the control applications have many facets and this internship experience dealt with several of them.

  11. Evolution of phage display technology: from discovery to application.

    Science.gov (United States)

    Rahbarnia, Leila; Farajnia, Safar; Babaei, Hossein; Majidi, Jafar; Veisi, Kamal; Ahmadzadeh, Vahideh; Akbari, Bahman

    2017-03-01

    Phage display technology as a selection-based system is an attractive method for evolution of new biological drugs. Unique ability of phage libraries for displaying proteins on bacteriophage surfaces enable them to make a major contribution in diverse fields of researches related to the diagnosis and therapy of diseases. One of the great challenges facing researchers is the modification of phage display technology and the development of new applications. This article reviews the molecular basis of phage display library, and summarizes the novel and specific applications of this technique in the field of biological drugs development including therapeutic antibodies, peptides, vaccines, and catalytic antibodies.

  12. Millisecond accuracy video display using OpenGL under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    To measure people's reaction times to the nearest millisecond, it is necessary to know exactly when a stimulus is displayed. This article describes how to display stimuli with millisecond accuracy on a normal CRT monitor, using a PC running Linux. A simple C program is presented to illustrate how this may be done within X Windows using the OpenGL rendering system. A test of this system is reported that demonstrates that stimuli may be consistently displayed with millisecond accuracy. An algorithm is presented that allows the exact time of stimulus presentation to be deduced, even if there are relatively large errors in measuring the display time.

  13. Advanced Transport Operating System (ATOPS) color displays software description microprocessor system

    Science.gov (United States)

    Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.

    1992-01-01

    This document describes the software created for the Sperry Microprocessor Color Display System used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global reference section includes procedures and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight cathode ray tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.

  14. Radiation-associated breast tumors display a distinct gene expression profile

    DEFF Research Database (Denmark)

    Broeks, Annegien; Braaf, Linde M; Wessels, Lodewyk F A

    2010-01-01

    PURPOSE: Women who received irradiation for Hodgkin's lymphoma have a strong increased risk for developing breast cancer. Approximately 90% of the breast cancers in these patients can be attributed to their radiation treatment, rendering such series extremely useful to determine whether a common...... radiation-associated cause underlies the carcinogenic process. METHODS AND MATERIALS: In this study we used gene expression profiling technology to assess gene expression changes in radiation-associated breast tumors compared with a set of control breast tumors of women unexposed to radiation, diagnosed...... at the same age. RNA was obtained from fresh frozen tissue samples from 22 patients who developed breast cancer after Hodgkin's lymphoma (BfHL) and from 20 control breast tumors. RESULTS: Unsupervised hierarchical clustering of the profile data resulted in a clustering of the radiation-associated tumors...

  15. Radiation-associated breast tumors display a distinct gene expression profile

    NARCIS (Netherlands)

    Broeks, Annegien; Braaf, Linde M.; Wessels, Lodewyk F. A.; van de Vijver, Marc; de Bruin, Marie L.; Stovall, Marilyn; Russell, Nicola S.; van Leeuwen, Flora E.; van 't Veer, Laura J.

    2010-01-01

    PURPOSE: Women who received irradiation for Hodgkin's lymphoma have a strong increased risk for developing breast cancer. Approximately 90% of the breast cancers in these patients can be attributed to their radiation treatment, rendering such series extremely useful to determine whether a common

  16. Data displays for multi-detector monitoring systems

    International Nuclear Information System (INIS)

    Barnes, R.C.M.

    1978-03-01

    Extensive installations of sensors are used for environmental surveillance of radiological hazards, fire, etc. The data from such arrays of detectors can be collected by data processing systems which generate appropriate supervisory displays and records. This paper reviews facilities and physical configurations of computer-based display systems, with particular reference to radiological protection schemes. The general principles are relevant to other fields of application. (author)

  17. Future of photorefractive based holographic 3D display

    Science.gov (United States)

    Blanche, P.-A.; Bablumian, A.; Voorakaranam, R.; Christenson, C.; Lemieux, D.; Thomas, J.; Norwood, R. A.; Yamamoto, M.; Peyghambarian, N.

    2010-02-01

    The very first demonstration of our refreshable holographic display based on photorefractive polymer was published in Nature early 20081. Based on the unique properties of a new organic photorefractive material and the holographic stereography technique, this display addressed a gap between large static holograms printed in permanent media (photopolymers) and small real time holographic systems like the MIT holovideo. Applications range from medical imaging to refreshable maps and advertisement. Here we are presenting several technical solutions for improving the performance parameters of the initial display from an optical point of view. Full color holograms can be generated thanks to angular multiplexing, the recording time can be reduced from minutes to seconds with a pulsed laser, and full parallax hologram can be recorded in a reasonable time thanks to parallel writing. We also discuss the future of such a display and the possibility of video rate.

  18. GridOrbit public display

    DEFF Research Database (Denmark)

    Ramos, Juan David Hincapie; Tabard, Aurélien; Bardram, Jakob

    2010-01-01

    We introduce GridOrbit, a public awareness display that visualizes the activity of a community grid used in a biology laboratory. This community grid executes bioin-formatics algorithms and relies on users to donate CPU cycles to the grid. The goal of GridOrbit is to create a shared awareness about...

  19. Design and Implementation of a Wireless Message Display System

    Directory of Open Access Journals (Sweden)

    M. U. M. Bakura

    2016-08-01

    Full Text Available The technology of displaying message is an important part of communication and advertisement. In recent times, Wireless communication has announced its arrival on big stage and the world is going with Smartphone technology. This work describes the design and implementation of a microcontroller based messaging display system. The messaging display system will be interfaced with an android application which will then be used to display information from the comfort of one‘s phone to an LCD screen using the Bluetooth application interface. The work employs the use of an ATMEGA328p Microcontroller mounted on an Arduino board, a Bluetooth Module (HC-06 and an LCD screen. Most of these electronic display systems were using wired cable connections, the Bluetooth technology used in this work is aimed at solving the problem of wired cable connections.The microcontroller provides all the functionality of the display notices and wireless control. A desired text message from a mobile phone is sent via android mobile application to the Bluetooth module located at the receiving end. The Mobile Application was created using online software called App Inventor. When the entire system was connected and tested, it functioned as designed without any noticeable problems. The Bluetooth module responded to commands being sent from the android application appropriately and in a timely manner. The system was able to display 80 characters on the 4 x 20 LCD within the range of 10m as designated by the Bluetooth datasheet.

  20. Role of computer graphics in space telerobotics - Preview and predictive displays

    Science.gov (United States)

    Bejczy, Antal K.; Venema, Steven; Kim, Won S.

    1991-01-01

    The application of computer graphics in space telerobotics research and development work is briefly reviewed and illustrated by specific examples implemented in real time operation. The applications are discussed under the following four major categories: preview displays, predictive displays, sensor data displays, and control system status displays.

  1. Qinshan plant display system: experience to date

    International Nuclear Information System (INIS)

    Bin, L.; Jiangdong, Y.; Weili, C.; Haidong, W.; Wangtian, L.; Lockwood, R.; Doucet, R.; Trask, D.; Judd, R.

    2004-01-01

    The two CANDU 6 units operated by the Third Qinshan Nuclear Power Corporation (TQNPC) include, as part of a control centre upgrade, a new plant display system (PDS). The PDS provides plant operators with new display and monitoring functionality designed to compliment the DCC capability. It includes new overview and trend displays (e.g., critical safety parameter monitor and user-defined trends), and enhanced annunciation based on AECL's Computerized Alarm Message List System (CAMLS) including an alarm interrogation capability. This paper presents a review of operating experience gained since the PDS was commissioned more than three years ago. It includes feedback provided by control room operators and trainers, PDS maintainers, and AECL development and support staff. It also includes an overview of improvements implemented since the PDS and suggestions for the future enhancements. (author)

  2. 33 CFR 181.29 - Hull identification number display.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Hull identification number... SECURITY (CONTINUED) BOATING SAFETY MANUFACTURER REQUIREMENTS Identification of Boats § 181.29 Hull identification number display. Two identical hull identification numbers are required to be displayed on each...

  3. Instrument for 3D characterization of autostereoscopic displays

    Science.gov (United States)

    Prévoteau, J.; Chalençon-Piotin, S.; Debons, D.; Lucas, L.; Remion, Y.

    2011-03-01

    We now have numerous autostereoscopic displays, and it is mandatory to characterize them because it will allow to optimize their performances and to make efficient comparison between them. Therefore we need standards so we have to be able to quantify the quality of the viewer's perception. The purpose of the present paper is twofold; we first present a new instrument of characterization of the 3D perception on a given autostereoscopic display; then we propose a new way to realize an experimental protocol allowing to get a full characterization. This instrument will allow us to compare efficiently the different autostereoscopic displays but it will also validate practically the adequacy between the shooting and rendering geometries. In this aim, we are going to match a perceived scene with the virtual scene. It is hardly possible to determine the scene perceived by a viewer placed in front of an autostereoscopic display. Indeed if it may be executable on the pop-out, it is impossible on the depth effect because the depth of the virtual scene is set behind the screen. Therefore, we will have to use an optical illusion based on the deflection of light by a mirror to know the position which the viewer perceives some points of the virtual scene on an autostereoscopic display.

  4. Graphic Display Development Program. Volume II, Revision 0. Appendices

    International Nuclear Information System (INIS)

    1984-12-01

    The objective of this project is to demonstrate the feasibility and utility of developing a set of graphic displays to support symptom-based emergency operating procedures (EOPs). Development of generic graphic displays is based on Revision 3 of the symptomatic Emergency Procedure Guidelines (EPGs) prepared by the BWR Owners' Group (BWROG), and development of plant-specific graphic displays is based on a set of emergency operating procedures developed from these EPGs

  5. Visualization and computer graphics on isotropically emissive volumetric displays.

    Science.gov (United States)

    Mora, Benjamin; Maciejewski, Ross; Chen, Min; Ebert, David S

    2009-01-01

    The availability of commodity volumetric displays provides ordinary users with a new means of visualizing 3D data. Many of these displays are in the class of isotropically emissive light devices, which are designed to directly illuminate voxels in a 3D frame buffer, producing X-ray-like visualizations. While this technology can offer intuitive insight into a 3D object, the visualizations are perceptually different from what a computer graphics or visualization system would render on a 2D screen. This paper formalizes rendering on isotropically emissive displays and introduces a novel technique that emulates traditional rendering effects on isotropically emissive volumetric displays, delivering results that are much closer to what is traditionally rendered on regular 2D screens. Such a technique can significantly broaden the capability and usage of isotropically emissive volumetric displays. Our method takes a 3D dataset or object as the input, creates an intermediate light field, and outputs a special 3D volume dataset called a lumi-volume. This lumi-volume encodes approximated rendering effects in a form suitable for display with accumulative integrals along unobtrusive rays. When a lumi-volume is fed directly into an isotropically emissive volumetric display, it creates a 3D visualization with surface shading effects that are familiar to the users. The key to this technique is an algorithm for creating a 3D lumi-volume from a 4D light field. In this paper, we discuss a number of technical issues, including transparency effects due to the dimension reduction and sampling rates for light fields and lumi-volumes. We show the effectiveness and usability of this technique with a selection of experimental results captured from an isotropically emissive volumetric display, and we demonstrate its potential capability and scalability with computer-simulated high-resolution results.

  6. Presentation of Various Tactile Sensations Using Micro-Needle Electrotactile Display.

    Directory of Open Access Journals (Sweden)

    Mayuko Tezuka

    Full Text Available Tactile displays provoke tactile sensations by artificially stimulating tactile receptors. While many types of tactile displays have been developed, electrotactile displays that exploit electric stimulation can be designed to be thin, light, flexible and thus, wearable. However, the high voltages required to stimulate tactile receptors and limited varieties of possible sensations pose problems. In our previous work, we developed an electrotactile display using a micro-needle electrode array that can drastically reduce the required voltage by penetrating through the high-impedance stratum corneum painlessly, but displaying various tactile sensations was still a challenge. In this work, we demonstrate presentation of tactile sensation of different roughness to the subjects, which is enabled by the arrangement of the electrodes; the needle electrodes are on the fingertip and the ground electrode is on the fingernail. With this arrangement, the display can stimulate the tactile receptors that are located not only in the shallow regions of the finger but also those in the deep regions. It was experimentally revealed that the required voltage was further reduced compared to previous devices and that the roughness presented by the display was controlled by the pulse frequency and the switching time, or the stimulation flow rate. The proposed electrotactile display is readily applicable as a new wearable haptic device for advanced information communication technology.

  7. What makes health promotion research distinct?

    Science.gov (United States)

    Woodall, James; Warwick-Booth, Louise; South, Jane; Cross, Ruth

    2018-02-01

    There have been concerns about the decline of health promotion as a practice and discipline and, alongside this, calls for a clearer articulation of health promotion research and what, if anything, makes it distinct. This discussion paper, based on a review of the literature, the authors' own experiences in the field, and a workshop delivered by two of the authors at the 8th Nordic Health Promotion Conference, seeks to state the reasons why health promotion research is distinctive. While by no means exhaustive, the paper suggests four distinctive features. The paper hopes to be a catalyst to enable health promotion researchers to be explicit in their practice and to begin the process of developing an agreed set of research principles.

  8. Graphic display of spatially distributed binary-state experimental data

    International Nuclear Information System (INIS)

    Watson, B.L.

    1981-01-01

    Experimental data collected from a large number of transducers spatially distributed throughout a three-dimensional volume has typically posed a difficult interpretation task for the analyst. This paper describes one approach to alleviating this problem by presenting color graphic displays of experimental data; specifically, data representing the dynamic three-dimensional distribution of cooling fluid collected during the reflood and refill of simulated nuclear reactor vessels. Color-coded binary data (wet/dry) are integrated with a graphic representation of the reactor vessel and displayed on a high-resolution color CRT. The display is updated with successive data sets and made into 16-mm movies for distribution and analysis. Specific display formats are presented and extension to other applications discussed

  9. SureTrak Probability of Impact Display

    Science.gov (United States)

    Elliott, John

    2012-01-01

    The SureTrak Probability of Impact Display software was developed for use during rocket launch operations. The software displays probability of impact information for each ship near the hazardous area during the time immediately preceding the launch of an unguided vehicle. Wallops range safety officers need to be sure that the risk to humans is below a certain threshold during each use of the Wallops Flight Facility Launch Range. Under the variable conditions that can exist at launch time, the decision to launch must be made in a timely manner to ensure a successful mission while not exceeding those risk criteria. Range safety officers need a tool that can give them the needed probability of impact information quickly, and in a format that is clearly understandable. This application is meant to fill that need. The software is a reuse of part of software developed for an earlier project: Ship Surveillance Software System (S4). The S4 project was written in C++ using Microsoft Visual Studio 6. The data structures and dialog templates from it were copied into a new application that calls the implementation of the algorithms from S4 and displays the results as needed. In the S4 software, the list of ships in the area was received from one local radar interface and from operators who entered the ship information manually. The SureTrak Probability of Impact Display application receives ship data from two local radars as well as the SureTrak system, eliminating the need for manual data entry.

  10. The effect of rubber flooring on displaying stereotypies in gilts.

    Science.gov (United States)

    Ostović, Mario; Menčik, Sven; Kabalin, Anamaria Ekert; Gračner, Gordana Gregurić; Vučemilo, Marija; Matković, Kristina; Vukičević, Tajana Trbojević; Grahovac, Jurica; Pavičić, Zeljko

    2015-01-01

    The aim of the study was to assess the effect of rubber mats in service unit on displaying stereotypies in gilts. Four 28-day production cycles in all seasons were observed. Each cycle included 28 gilts housed in gestation stalls with slatted concrete floor, which was covered with adjusted mats for 14 gilts (experimental group), while the remaining 14 gilts served as controls. Display of stereotypies and other behaviours observed, mat manipulation and postural behaviours were estimated by direct 1-hour observation of gilts at 2-minute intervals after morning feed supply on days 1, 8, 15 and 28 of each cycle. During the study period, displaying stereotypies was significantly less frequent (P 0.05 all) between the frequency of displaying stereotypies and the frequency of lying and other postures observed, as well as between the stereotypy display and the air temperature. There was no significant correlation (P > 0.05 all) between the frequency of mat manipulation and displaying stereotypies in total or its particular forms, suggesting that the less pronounced stereotypy display in experimental gilts may have been influenced by factors other than those observed in the present study.

  11. Cockpit Displays to Support Hazard Awareness in Free Flight

    Science.gov (United States)

    Wickens, Christopher D.; Carbonari, Ron; Merwin, Dave; Morphew, Ephimia; OBrien, Janelle V.

    1997-01-01

    Three experiments are described which each examine different aspects of the formatting and integration of cockpit displays of traffic information to support pilots in traffic avoidance planning. The first two experiments compared two-dimensional (coplanar) with three-dimensional (perspective) versions of a cockpit display of traffic information. In Experiment 1, 30 certified flight instructors flew a series of traffic conflict detection and avoidance maneuvers around an intruder aircraft, sometimes in the presence of a second intruder. The results revealed an advantage for the coplanar display, particularly when there was vertical intruder behavior. In Experiment 2, 17 instructors flew with the coplanar and perspective formats when weather information was either overlaid or displayed separately. Again performance was best with the coplanar display, particularly when the weather data were overlaid. The results of both experiments are also discussed in ten-ns of the traffic maneuver stereotypes exhibited by the pilots. Experiment 3 examined the benefits of the two different predictor elements used in the coplanar displays of Experiments 1 and 2. The study was carried out in a multitask context. These elements were both found to improve safety (reduce actual and predicted conflicts) and to reduce workload, although the different elements affected workload in different ways. Neither predictor element imposed a cost to concurrent task performance.

  12. Distinct transmitter release properties determine differences in short-term plasticity at functional and silent synapses.

    Science.gov (United States)

    Cabezas, Carolina; Buño, Washington

    2006-05-01

    Recent evidence suggests that functional and silent synapses are not only postsynaptically different but also presynaptically distinct. The presynaptic differences may be of functional importance in memory formation because a proposed mechanism for long-term potentiation is the conversion of silent synapses into functional ones. However, there is little direct experimentally evidence of these differences. We have investigated the transmitter release properties of functional and silent Schaffer collateral synapses and show that on the average functional synapses displayed a lower percentage of failures and higher excitatory postsynaptic current (EPSC) amplitudes than silent synapses at +60 mV. Moreover, functional but not silent synapses show paired-pulse facilitation (PPF) at +60 mV and thus presynaptic short-term plasticity will be distinct in the two types of synapse. We examined whether intraterminal endoplasmic reticulum Ca2+ stores influenced the release properties of these synapses. Ryanodine (100 microM) and thapsigargin (1 microM) increased the percentage of failures and decreased both the EPSC amplitude and PPF in functional synapses. Caffeine (10 mM) had the opposite effects. In contrast, silent synapses were insensitive to both ryanodine and caffeine. Hence we have identified differences in the release properties of functional and silent synapses, suggesting that synaptic terminals of functional synapses express regulatory molecular mechanisms that are absent in silent synapses.

  13. Clinical evaluation of a medical high dynamic range display

    International Nuclear Information System (INIS)

    Marchessoux, Cedric; Paepe, Lode de; Vanovermeire, Olivier; Albani, Luigi

    2016-01-01

    Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM HDR is slightly higher than FoM LDR with 0.09% of difference. For the difficult nodules, the averaged FoM HDR is slightly higher than FoM LDR with 1.38% of difference. The averaged FoM HDR is slightly higher than FoM LDR with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in

  14. Volumetric 3D display using a DLP projection engine

    Science.gov (United States)

    Geng, Jason

    2012-03-01

    In this article, we describe a volumetric 3D display system based on the high speed DLPTM (Digital Light Processing) projection engine. Existing two-dimensional (2D) flat screen displays often lead to ambiguity and confusion in high-dimensional data/graphics presentation due to lack of true depth cues. Even with the help of powerful 3D rendering software, three-dimensional (3D) objects displayed on a 2D flat screen may still fail to provide spatial relationship or depth information correctly and effectively. Essentially, 2D displays have to rely upon capability of human brain to piece together a 3D representation from 2D images. Despite the impressive mental capability of human visual system, its visual perception is not reliable if certain depth cues are missing. In contrast, volumetric 3D display technologies to be discussed in this article are capable of displaying 3D volumetric images in true 3D space. Each "voxel" on a 3D image (analogous to a pixel in 2D image) locates physically at the spatial position where it is supposed to be, and emits light from that position toward omni-directions to form a real 3D image in 3D space. Such a volumetric 3D display provides both physiological depth cues and psychological depth cues to human visual system to truthfully perceive 3D objects. It yields a realistic spatial representation of 3D objects and simplifies our understanding to the complexity of 3D objects and spatial relationship among them.

  15. Survey of standards for electronic image displays

    Science.gov (United States)

    Rowe, William A.

    1996-02-01

    Electronic visual displays have been evolving from the 1960's basis of cathode ray tube (CRT) technology. Now, many other technologies are also available, including both flat panels and projection displays. Standards for these displays are being developed at both the national level and the international levels. Standards activity within the United States is in its infancy and is fragmented according to the inclination of each of the standards developing organizations. The latest round of flat panel display technology was primarily developed in Japan. Initially standards arose from component vendor-to-OEM customer relationships. As a result, Japanese standards for components are the best developed. The Electronics Industries Association of Japan (EIAJ) is providing their standards to the International Electrotechnical Commission (IEC) for adoption. On the international level, professional societies such as the human factors society (hfs) and the International Organization for Standardization (ISO) have completed major standards, hfs developed the first ergonomic standard hfs-100 and the ISO has developed some sections of a broader ergonomic standard ISO 9241. This paper addresses the organization of standards activity. Active organizations and their areas of focus are identified. The major standards that have been completed or are in development are described. Finally, suggestions for improving the this standards activity are proposed.

  16. Children's Understanding of Verbal and Facial Display Rules

    Science.gov (United States)

    Gnepp, Jackie; Hess, Debra L. R.

    1986-01-01

    First-, third-, fifth-, and tenth-grade children listened to eight stories designed to elicit prosocial or self-protective display rules. Children predicted protagonists' verbal and facial expressions to emotion-laden situations. Findings indicated knowledge of control of emotional displays increases between first and fifth grades, but then levels…

  17. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  18. Recreational atmospheric pollution episodes: Inhalable metalliferous particles from firework displays

    Science.gov (United States)

    Moreno, Teresa; Querol, Xavier; Alastuey, Andrés; Cruz Minguillón, Mari; Pey, Jorge; Rodriguez, Sergio; Vicente Miró, José; Felis, Carles; Gibbons, Wes

    The use of fireworks creates an unusual and distinctive anthropogenic atmospheric pollution event. We report on aerosol samples collected during Las Fallas in Valencia, a 6-day celebration famous for its firework displays, and add comparative data on firework- and bonfire-contaminated atmospheric aerosol samples collected from elsewhere in Spain (Barcelona, L'Alcora, and Borriana) and during the Guy Fawkes celebrations in London. Specific high-profile official firework events during Las Fallas included the afternoon Mascletà and the nightly aerial displays (especially in the climactic final 2 days of the fiesta) and were accompanied by pollution spikes in suspended particles, NO, SO 2, and the creation and dispersal of an aerosol cloud enriched in a range of metallic elements. Notable metal aerosol concentration increases recorded during Las Fallas were potassium (from 500 to 5900 ng m -3), aluminium (as Al 2O 3 from around 600 to 2200 ng m -3), titanium (from 200 to 700 ng m -3), magnesium (from 100 to 500 ng m -3), lead (from 17 to 379 ng m -3), barium (from 39 to 322 ng m -3), strontium (from 3 to 112 ng m -3), copper (from 12 to 71 ng m -3), and antimony (from 1 to 52 ng m -3). Firework-contaminated aerosols of similarly metalliferous composition were also identified at the other monitoring sites, although different sites show variations attributable to other sources such as bonfires and local industry. Unusual levels of the trace elements Ba, Sr and (to a lesser extent) Cu, always in proportions with Ba dominant, along with strongly enhanced K, Pb, and Sb, are identified as being particularly characteristic of firework aerosols. Although firework-related recreational pollution episodes are transient in nature, they are highly concentrated, contribute significantly to total annual metal emissions, and are on average fine enough to be easily inhaled and a health risk to susceptible individuals.

  19. A head-up display for low-visibility approach and landing

    Science.gov (United States)

    Bray, R. S.; Scott, B. C.

    1981-01-01

    An electronic flight-guidance display format was designed for use in evaluations of the collimated head-up display concept in low-visibility landings of transport aircraft. In the design process of iterative evaluation and modification, some general principles, or guidelines, applicable to such flight displays were suggested. The usefulness of an indication of instantaneous inertial flightpath was clearly demonstrated, particularly in low-altitude transition to visual references. Evaluator pilot acceptance of the unfamiliar display concepts was very positive when careful attention was given to indoctrination and training.

  20. P3-1: Ophthalmologic Factors Influencing Asthenopia with Watching 3D Displays

    Directory of Open Access Journals (Sweden)

    Sungwook Wee

    2012-10-01

    Full Text Available Purpose: To identify ophthalmologic factors influencing asthenopia while watching 3D displays. Methods: 30 adult subjects without ophthalmologic abnormality watched the same 3D displays for 30 minutes. Each subject's far and near visual acuity, near points of accommodation and convergence, amplitude of fusional convergence and divergence, stereopsis, angle of phoric deviation, tear break-up time, and temperature of ocular surface before and after watching 3D displays were measured. And surveys for subjective symptoms right after watching 3D displays were conducted. The above-mentioned experiments were performed equally with 2D displays for detection of innate influence of 3D displays. Results: The near points of accommodation and convergence were significantly changed after watching 3D displays (p < .05 compared to 2D displays. And all 10 subjective symptoms were significantly increased after watching 3D displays (p < .05. Conclusion: The accommodation and binocular vergence are predominant ophthalmologic factors that might influence asthenopia significantly while watching 3D displays. Subjective visual discomfort significantly increases with watching 3D displays, and more specific evaluation should be added for detecting the practically related factors with asthenopia.