WorldWideScience

Sample records for massive tornado tore

  1. Tornadoes Strike Northern Wisconsin

    Science.gov (United States)

    2007-01-01

    A series of tornadoes ripped through the Upper Midwest region of the United States in the evening of June 7, 2007. At least five different tornadoes touched down in Wisconsin, according to the Associated Press, one of which tore through the Bear Paw Resort in northern Wisconsin. Despite dropping as much as fifteen centimeters (six inches) of rain in some places and baseball-size hail in others, authorities were reporting no deaths attributable to the storm system, and only a smattering of injuries, but considerable property damage in some areas. When the MODIS instrument on NASA's Terra satellite observed the area on June 9, 2007, the track torn through the woods by one of the tornadoes stands out quite clearly. This photo-like image uses data collected by MODIS in the normal human vision range to give a familiar natural-looking appearance. The landscape is largely a checkerboard of farms, towns, roads, and cities. The pale land is predominantly farmland where crops have not fully grown in yet. Dark blue shows the winding path of rivers and lakes dotting the landscape. The large blue lake on the east (right) side of the image is Lake Michigan. Towns and cities, including the city of Green Bay, are gray. To the north side, farmland gives way to dark green as land use shifts from agriculture to the Menominee Indian Reservation and Nicolet National Forest. The diagonal slash through the dark green forested land shows the tornado track. Bare land was revealed where the tornado tore down trees or stripped vegetation off the branches. The high-resolution image provided above is at MODIS' full spatial resolution (level of detail) of 250 meters per pixel. The MODIS Rapid Response System provides this image at additional resolutions.

  2. Massive pediatric neurosurgical injuries and lessons learned following a tornado disaster in Alabama.

    Science.gov (United States)

    Chern, Joshua J; Miller, Joseph H; Tubbs, R Shane; Whisenhunt, Thomas R; Johnston, James M; Wellons, John C; Rozzelle, Curtis J; Blount, Jeffrey P; Oakes, W Jerry

    2011-12-01

    A large volume of patients presented to a Level I pediatric trauma center during and after a recent tornado disaster. Injuries of the central and peripheral nervous systems and the medical responses of a pediatric neurosurgical team are reviewed. The clinical courses of patients who suffered cranial, spinal, and peripheral nerve injuries due to the tornado storm are reported. The clinical actions taken by the neurosurgical team during and after the event are reviewed and the lessons learned are discussed. The tornado storm system moved through the Tuscaloosa and Birmingham metropolitan areas on the early evening hours of April 27, 2011. Twenty-four patients received care from the neurosurgical team. A total of 11 cranial (including placement of an external ventricular drain), 2 spine, and 2 peripheral procedures were performed for the victims. Nine procedures were performed within the first 12 hours of the event, and an additional 6 surgeries were performed in the following 24 hours. Injuries of the peripheral nervous system often presented in a delayed fashion. Several key components were identified that enabled adequate neurosurgical care for a large influx of acute patients. Massive casualties due to tornados are rare. A well-organized physician team working with the hospital administration may decrease the mortality and morbidity of such events.

  3. Exploratory modeling: Extracting causality from complexity

    NARCIS (Netherlands)

    Larsen, L.; Thomas, C.; Eppinga, M.B.; Coulthard, T.

    2014-01-01

    On 22 May 2011 a massive tornado tore through Joplin, Mo., killing 158 people. With winds blowing faster than 200 miles per hour, the tornado was the most deadly in the United States since modern record keeping began in the 1950s.

  4. Disruption mitigation on Tore Supra

    International Nuclear Information System (INIS)

    Martin, G.; Sourd, F.; Saint-Laurent, F.; Bucalossi, J.; Eriksson, L.G.

    2004-01-01

    During disruptions, the plasma energy is lost on the first wall within 1 ms, forces up to hundred tons are applied to the structures and kA of electrons are accelerated up to 50 MeV (runaway electrons). Already sources of concern in present day tokamaks, extrapolation to ITER shows the necessity of mitigation procedures, to avoid serious damages to in-vessel components. Massive gas injection was proposed, and encouraging tests have been done on Textor and DIII-D. Similar experiments where performed on Tore Supra, with the goal to validate their effect on runaway electrons, observed during the majority of disruptions. 0.1 mole of helium was injected within 5 ms in ohmic plasmas, up to 1.2 MA, either stable, or in a pre-disruptive phase (argon puffing). Beneficial effects where obtained: reduction of the current fall rate and eddy currents, total disappearance of runaway electrons and easy recovery for the next pulse, without noticeable helium pollution of following plasmas. Analysis of the 4 ms period between injection and disruption indicates that to reach these goals, one need to inject enough helium to keep it only partially ionised. It corresponds to 0.1 g for Tore Supra, and extrapolate to hundreds of grams for ITER. (authors)

  5. Disruption mitigation on Tore Supra

    International Nuclear Information System (INIS)

    Martin, G.; Sourd, F.; Saint-Laurent, F.; Bucalossi, J.; Eriksson, L.G.

    2005-01-01

    During disruptions, the plasma energy is lost on the first wall within 1 ms, forces up to hundred tons are applied to the structures and kA of electrons are accelerated up to 50 MeV (runaway electrons). Already sources of concern in present day tokamaks, extrapolation to ITER shows the necessity of mitigation procedures, to avoid serious damages to in-vessel components. Massive gas injection was proposed, and encouraging tests have been done on Textor and DIII-D. Similar experiments where performed on Tore Supra, with the goal to validate their effect on runaway electrons, observed during the majority of disruptions. 0.1 mole of helium was injected within 5 ms in ohmic plasmas, up to 1.2 MA, either stable, or in a pre-disruptive phase (argon puffing). Beneficial effects where obtained: reduction of the current fall rate and eddy currents, total disappearance of runaway electrons and easy recovery for the next pulse, without noticeable helium pollution of following plasmas. Analysis of the 4 ms period between injection and disruption indicates that to reach these goals, one need to inject enough helium to keep it only partially ionised. It correspond to 0.1 g for Tore Supra, and extrapolate to hundred's of grams for ITER. (author)

  6. Tore Supra

    International Nuclear Information System (INIS)

    Supra, E.T.

    1989-01-01

    Tore Supra is a tokamak implemented on the site of CEN Cadarache by the EURATOM-CEA Association. The machine technology integrates all problems related to the fabrication and the operation of large cyrogenic superconducting coils and of the associated cryogenic system. Tore Supra will provide a significant experience to prepare the next generation of machines for controlled design. Tore Supra has been designed to implement a lage physics program that takes advantage of the capability of operation with plasma pulses in excess of 30 seconds. Operation started in April, with a toroidal field of 2 teslas. Discharges of 500 kA with a 3 second current flat top were obtained after a few days. Machine parameters will be raised to their nominal values ( B -- 4.5 Teslas and Ip -- 1.7 MA) during summer

  7. Statistics of severe tornadoes and severe tornado outbreaks

    Directory of Open Access Journals (Sweden)

    B. D. Malamud

    2012-09-01

    Full Text Available The standard measures of the intensity of a tornado in the USA and many other countries are the Fujita and Enhanced Fujita scales. These scales are based on the damage that a tornado causes. Another measure of the strength of a tornado is its path length of touchdown, L. In this study we consider severe tornadoes, which we define as L≥10 km, in the continental USA (USA Storm Prediction Center Severe Weather Database. We find that for the period 1982–2011, for individual severe tornadoes (L≥10 km: (i There is a strong linear scaling between the number of severe tornadoes in a year and their total path length in that year. (ii The cumulative frequency path length data suggests that, not taking into account any changing trends over time, we would expect in a given year (on average one severe tornado with a path length L≥115 km and in a decade (on average one severe tornado with a path length L≥215 km. (iii The noncumulative frequency-length statistics of severe tornado touchdown path lengths, 20<L<200 km, is well approximated by an inverse power-law relationship with exponent near 3. We then take the total path length of severe tornadoes in a convective day (12:00–12:00 UTC, LD, as a measure of the strength of a 24-h USA tornado outbreak. We find that: (i For 1982–2011, the number of severe tornadoes in a USA convective day outbreak has a strong power-law relationship (exponent 0.80 on the convective day total path length, LD. (ii For 1952–2011, the cumulative frequency path length data for severe tornado outbreaks suggests that we would expect in a given year (on average one daily severe tornado outbreak with total path length LD≥480 km and in a decade (on average one daily severe tornado outbreak with a total path length LD≥1200 km. (iii For 1982–2011, the noncumulative frequency-length statistics of tornado

  8. Tornado lift

    OpenAIRE

    Ivanchin, Alexander

    2010-01-01

    It is shown that one of the causes for tornado is Tornado Lift. At increasing vortex diameter its kinetic energy decreases to keep the moment of momentum constant. A kinetic energy gradient of such vortex is Tornado Lift. Evaluation shows that contribution of Tornado Lift in air lifting in a tornado is comparable to buoyancy according to the order of magnitude.

  9. Tore Supra: technical description

    International Nuclear Information System (INIS)

    1985-08-01

    This report is aimed, after a brief recall of physics and technologic perspectives of Tore Supra, at giving a detailed description of the basic machine; details of each component are defined. Volume 1 is specifically concerned with the general aspects of Tore Supra and the toroidal field system [fr

  10. Tame a Tornado

    Science.gov (United States)

    Cronin, Jim

    2003-01-01

    The author was looking for a demonstration that actually used wind shear forces to set up the tornado effect when he saw a video produced by The Tornado Project called "Secrets of the Tornado". This video not only shows dozens of actual tornadoes, but also gives construction techniques for several different styles of tornado boxes that are…

  11. The Tornado.

    Science.gov (United States)

    Snow, John T.

    1984-01-01

    Although tornadoes have been one of the most elusive phenomena in meteorology, new observation techniques are now revealing how they are spawned by thunderstorms. Tornado structure and formation, thunderstorms, tornadic thunderstorms, and the evolution and structure of such thunderstorms are considered. Why the Midwest has frequent tornadoes is…

  12. Tornado-related fatalities--five states, Southeastern United States, April 25-28, 2011.

    Science.gov (United States)

    2012-07-20

    During April 25-28, 2011, a massive storm system generated 351 tornadoes (including 15 registering 4 or 5 on the Enhanced Fujita [EF] scale*), killing 338 persons in Alabama, Arkansas, Georgia, Mississippi, and Tennessee. This was the third-deadliest tornado event in the United States, surpassing an April 1974 event that resulted in 315 fatalities. This event also was historic because of the record number of fatalities that occurred despite modern advances in tornado forecasting, advanced warning times, and media coverage. Risk factors for death and injury from tornadoes are sheltering in mobile homes, proximity to an EF-4 or EF-5 tornado, being an older adult (aged ≥65 years), lack of accessibility to safe rooms (e.g., basements or reinforced shelters), and a night-time tornado impact. To describe the fatalities by demographic characteristics, type of shelter used, cause of death, and tornado severity and location, CDC reviewed data from the American Red Cross (Red Cross), death certificates, and the National Weather Service (NWS). This report summarizes the results of that review. Among the 338 decedents, median age was 55.0 years (range: 4 days-97 years); approximately one third were older adults. On tornado impact, 46.7% of decedents were in single-family homes, and 26.6% were in mobile homes. The leading cause of death was traumatic injury, including 21.9% with head injuries. Half of the deadly tornadoes were rated EF-4 or EF-5 and were responsible for 89.5% of the deaths. To prevent tornado-related deaths, health messaging should encourage the public (especially older adults and residents of mobile/manufactured homes) to pre-identify an accessible safe room, prepare the room with personal protection items (e.g., blankets and helmets), and monitor local weather.

  13. Proposing a tornado watch scale

    Science.gov (United States)

    Mason, Jonathan Brock

    This thesis provides an overview of language used in tornado safety recommendations from various sources, along with developing a rubric for scaled tornado safety recommendations, and subsequent development and testing of a tornado watch scale. The rubric is used to evaluate tornado refuge/shelter adequacy responses of Tuscaloosa residents gathered following the April 27, 2011 Tuscaloosa, Alabama EF4 tornado. There was a significant difference in the counts of refuge adequacy for Tuscaloosa residents when holding the locations during the April 27th tornado constant and comparing adequacy ratings for weak (EF0-EF1), strong (EF2-EF3) and violent (EF4-EF5) tornadoes. There was also a significant difference when comparing future tornado refuge plans of those same participants to the adequacy ratings for weak, strong and violent tornadoes. The tornado refuge rubric is then revised into a six-class, hierarchical Tornado Watch Scale (TWS) from Level 0 to Level 5 based on the likelihood of high-impact or low-impact severe weather events containing weak, strong or violent tornadoes. These levels represent maximum expected tornado intensity and include tornado safety recommendations from the tornado refuge rubric. Audio recordings similar to those used in current National Oceanic and Atmospheric Administration (NOAA) weather radio communications were developed to correspond to three levels of the TWS, a current Storm Prediction Center (SPC) tornado watch and a particularly dangerous situation (PDS) tornado watch. These were then used in interviews of Alabama residents to determine how changes to the information contained in the watch statements would affect each participant's tornado safety actions and perception of event danger. Results from interview participants (n=38) indicate a strong preference (97.37%) for the TWS when compared to current tornado watch and PDS tornado watch statements. Results also show the TWS elicits more adequate safety decisions from participants

  14. More tornadoes in the most extreme U.S. tornado outbreaks.

    Science.gov (United States)

    Tippett, Michael K; Lepore, Chiara; Cohen, Joel E

    2016-12-16

    Tornadoes and severe thunderstorms kill people and damage property every year. Estimated U.S. insured losses due to severe thunderstorms in the first half of 2016 were $8.5 billion (US). The largest U.S. effects of tornadoes result from tornado outbreaks, which are sequences of tornadoes that occur in close succession. Here, using extreme value analysis, we find that the frequency of U.S. outbreaks with many tornadoes is increasing and that it is increasing faster for more extreme outbreaks. We model this behavior by extreme value distributions with parameters that are linear functions of time or of some indicators of multidecadal climatic variability. Extreme meteorological environments associated with severe thunderstorms show consistent upward trends, but the trends do not resemble those currently expected to result from global warming. Copyright © 2016, American Association for the Advancement of Science.

  15. Spatial-Temporal Clustering of Tornadoes

    Science.gov (United States)

    Malamud, Bruce D.; Turcotte, Donald L.; Brooks, Harold E.

    2017-04-01

    The standard measure of the intensity of a tornado is the Enhanced Fujita scale, which is based qualitatively on the damage caused by a tornado. An alternative measure of tornado intensity is the tornado path length, L. Here we examine the spatial-temporal clustering of severe tornadoes, which we define as having path lengths L ≥ 10 km. Of particular concern are tornado outbreaks, when a large number of severe tornadoes occur in a day in a restricted region. We apply a spatial-temporal clustering analysis developed for earthquakes. We take all pairs of severe tornadoes in observed and modelled outbreaks, and for each pair plot the spatial lag (distance between touchdown points) against the temporal lag (time between touchdown points). We apply our spatial-temporal lag methodology to the intense tornado outbreaks in the central United States on 26 and 27 April 2011, which resulted in over 300 fatalities and produced 109 severe (L ≥ 10 km) tornadoes. The patterns of spatial-temporal lag correlations that we obtain for the 2 days are strikingly different. On 26 April 2011, there were 45 severe tornadoes and our clustering analysis is dominated by a complex sequence of linear features. We associate the linear patterns with the tornadoes generated in either a single cell thunderstorm or a closely spaced cluster of single cell thunderstorms moving at a near-constant velocity. Our study of a derecho tornado outbreak of six severe tornadoes on 4 April 2011 along with modelled outbreak scenarios confirms this association. On 27 April 2011, there were 64 severe tornadoes and our clustering analysis is predominantly random with virtually no embedded linear patterns. We associate this pattern with a large number of interacting supercell thunderstorms generating tornadoes randomly in space and time. In order to better understand these associations, we also applied our approach to the Great Plains tornado outbreak of 3 May 1999. Careful studies by others have associated

  16. Edge plasma diagnostics on Tore Supra tokamak

    International Nuclear Information System (INIS)

    Fujita, Junji

    1991-01-01

    From 1988 to 1991, the international scientific research 'Diagnosis of peripheral plasma in Tore Supra tokamak' was carried out as a three-year plan receiving the support of the scientific research expense of the Ministry of Education. This is to apply the method of measuring electron density distribution by neutral lithium beam probe spectroscopy to the measurement of the electron density distribution in the peripheral plasma in Tore Supra Tokamak in France. Among many tokamaks in operation doing respective characteristics researches, the Tore Supra generates the toroidal magnetic field by using superconducting coils, and aims at the long time discharge for 30 sec. for the time being, and for 300 sec. in future. In the plasma generators for long time discharge like this, the technology of particle control is a large problem. For this purpose, a divertor was added to the Tore Supra. In order to advance the research on particle control, it is necessary to examine the behavior of plasma in the peripheral part in detail. The measurement of peripheral plasma in tokamaks, beam probe spectroscopy, the Tore Supra tokamak, the progress of the joint research, the problems in the joint research and the perspective of hereafter are reported. (K.I.)

  17. Tornado Mechanics

    Science.gov (United States)

    1976-01-01

    The Nimbus and other weather satellites are helping determine why and how tornadoes form their structure and dynamics and ultimately how they can be prevented or artificially dissipated. NASA's Marshall Space Flight Center is also planning a cooperative research program later this year with the University of Arkansas to investigate how tornado damage occurs, and to develop tornado resistant building designs. Hardware and field-data collection are funded by the Technology Utilization Office while data reduction is being performed by the National Oceanic and Atmospheric Administration.

  18. Weather Advisory: Tornados | Poster

    Science.gov (United States)

    Summer months carry the threat of severe storms and tornados in our area. Take a few moments to consider how well you are prepared in the event of a tornado warning. The time to prepare for a tornado is before it happens. The Federal Emergency Management Agency (FEMA) provides information on how to prepare and what to do in the event of a tornado. Take a few moments to read

  19. Tornado Chasing.

    Science.gov (United States)

    Faidley, Warren

    1991-01-01

    Presents the rationale and purposes behind the phenomenon known as storm chasing, as well as the contributions that tornado chasers have made to both scientific knowledge and public safety. Provides statistical information on tornado frequencies and locations and contact addresses for storm chasers. (JJK)

  20. LABORATORY MODELING OF TORNADOES

    OpenAIRE

    文字, 信貴

    1982-01-01

    Laboratory modelings of the tornado vortices are overviewed. Modelings of the mesocyclone as theboundary conditions in the tornado simulations are found to have significant problems especially on thesource of thunderstorm and tornado rotation. A number of the problems related to the vortex structuresuch as the wind profiles or the role of turbulence are left unsolved. However, the simulated vortices arefound to have many common characteristics with the tornado vortices in nature, which sugges...

  1. Study of plasma-wall interactions in Tore-supra; Etude des phenomenes d'interaction plasma/paroi dans Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, R

    2000-01-01

    In tokamaks the interaction between wall and plasma generates impurities that affect the thermonuclear fusion. This thesis is divided into 2 parts. The first part describes the physico-chemical processes that are involved in chemical erosion, the second part deals with the study of the wear of Tore-supra's walls due to chemical erosion. Chapter 1 presents the wall-plasma interaction and reviews the different processes between plasma and carbon that occur in Tore-supra. Chapter 2 considers the various crystallographic and electronic structures of the carbon that interferes with Tore-supra plasma, the evolution of these structures during irradiation and their temperature dependence are studied. Chapter 3 presents a crystallo-chemical study of graphite samples that have undergone different surface treatments: ionic bombardment, annealing and air exposure. This experimental study has been performed by using energy-loss spectroscopy. It is shown that air exposure modifies the crystallo-chemical structure of surfaces, so it is necessary to prevent air from contaminating wall samples from Tore-supra. Chapter 4 presents a parametric study of chemical erosion rate of plasma facing components (LPM) of Tore-supra. A relation such as Y{sub cd4}{alpha}{gamma}{sup -0.1} gives a good agreement for chemical erosion rate between measurements and the numerical values of the simulation. (A.C.)

  2. Seismic detection of tornadoes

    Science.gov (United States)

    Tatom, F. B.

    1993-01-01

    Tornadoes represent the most violent of all forms of atmospheric storms, each year resulting in hundreds of millions of dollars in property damage and approximately one hundred fatalities. In recent years, considerable success has been achieved in detecting tornadic storms by means of Doppler radar. However, radar systems cannot determine when a tornado is actually in contact with the ground, expect possibly at extremely close range. At the present time, human observation is the only truly reliable way of knowing that a tornado is actually on the ground. However, considerable evidence exists indicating that a tornado in contact with the ground produces a significant seismic signal. If such signals are generated, the seismic detection and warning of an imminent tornado can become a distinct possibility. 

  3. Prevention of child injuries during tornadoes: cases from the 2011 tornado outbreak in Alabama.

    Science.gov (United States)

    Campbell, Christine M; Baker, Mark D; Monroe, Kathy W

    2012-12-01

    Tornadoes and violent weather pose a hazard to children, yet little is known about the use of personal protective devices during storms. An outbreak of tornadoes on April 27, 2011, resulted in the deaths of 23 children in Alabama. Records from 60 patients seen in a pediatric emergency department for tornado-related injuries were reviewed to identify the use of injury prevention devices. Three children directly exposed to a violent tornado (Enhanced Fujita Scale 4) were using safety equipment, specifically, a helmet and infant car seats. These 3 children sustained only minor injuries. Personal protective devices may have played a role in preventing child injuries from tornadoes. To our knowledge, this is the first report in the medical literature on helmet and infant car seat use as child protective devices during tornadoes.

  4. Fast imaging system on Tore Supra

    International Nuclear Information System (INIS)

    Geraud, A.; Salasca, S.; Verger, J. M.; Alarcon, T.; Agarici, G.; Bremond, S.; Chenevois, J. P.; Geynet, M.; Migozzi, J. B.; Reux, C.

    2009-01-01

    A new endoscope aiming at transferring the image of a poloidal section of the Tore Supra plasma to a fast camera able to record frames at a speed up to 4800 frames per second at full resolution, or much faster for a limited number of pixel, has been installed on Tore Supra. First movies showing the light emission associated to fast phenomena such as plasma start up, disruptions or gas and pellet injections have been produced.

  5. Condensational theory of stationary tornadoes

    International Nuclear Information System (INIS)

    Makarieva, A.M.; Gorshkov, V.G.; Nefiodov, A.V.

    2011-01-01

    Using the Bernoulli integral for air streamline with condensing water vapor a stationary axisymmetric tornado circulation is described. The obtained profiles of vertical, radial and tangential velocities are in agreement with observations for the Mulhall tornado, world's largest on record and longest-lived among the three tornadoes for which 3D velocity data are available. Maximum possible vortex velocities are estimated. -- Highlights: → Water vapor condensation causes a logarithmic drop of air pressure towards tornado center. → The first ever theoretical description of tornado velocities is obtained. → The maximum vortex velocity grows logarithmically with decreasing tornado eye radius. → Air motion with high velocities can only develop in sufficiently large condensation areas.

  6. "SOLAR MAGNETIZED ""TORNADOES:"" RELATION TO FILAMENTS"

    OpenAIRE

    Su, Yang; Wang, Tongjiang; Veronig, Astrid; Temmer, Manuela; Gan, Weiqun

    2012-01-01

    Solar magnetized "tornadoes", a phenomenon discovered in the solar atmosphere, appear as tornado-like structures in the corona but root in the photosphere. Like other solar phenomena, solar tornadoes are a feature of magnetized plasma and therefore differ distinctly from terrestrial tornadoes. Here we report the first analysis of solar "tornadoes" {Two papers which focused on different aspect of solar tornadoes were published in the Astrophysical Journal Letters (Li et al. 2012) and Nature (W...

  7. Excitation of seismic waves by a tornado

    Science.gov (United States)

    Valovcin, A.; Tanimoto, T.; Twardzik, C.

    2016-12-01

    Tornadoes are among the most common natural disasters to occur in the United States. Various methods are currently used in tornado forecasting, including surface weather stations, weather balloons and satellite and Doppler radar. These methods work for detecting possible locations of tornadoes and funnel clouds, but knowing when a tornado has touched down still strongly relies on reports from spotters. Studying tornadoes seismically offers an opportunity to know when a tornado has touched down without requiring an eyewitness report. With the installation of Earthscope's Transportable Array (TA), there have been an increased number of tornadoes that have come within close range of seismometers. We have identified seismic signals corresponding to three tornadoes that occurred in 2011 in the central US. These signals were recorded by the TA station closest to each of the tornado tracks. For each tornado, the amplitudes of the seismic signals increase when the storm is in contact with the ground, and continue until the tornado lifts off some time later. This occurs at both high and low frequencies. In this study we will model the seismic signal generated by a tornado at low frequencies (below 0.1 Hz). We will begin by modeling the signal from the Joplin tornado, an EF5 rated tornado which occurred in Missouri on May 22, 2011. By approximating the tornado as a vertical force, we model the generated signal as the tornado moves along its track and changes in strength. By modeling the seismic waveform generated by a tornado, we can better understand the seismic-excitation process. It could also provide a way to quantitatively compare tornadoes. Additional tornadoes to model include the Calumet-El Reno-Piedmont-Guthrie (CEPG) and Chickasa-Blanchard-Newcastle (CBN) tornadoes, both of which occurred on May 24, 2011 in Oklahoma.

  8. Runaway electrons dynamics and confinement in Tore-Supra

    International Nuclear Information System (INIS)

    Chatelier, M.; Geraud, A.; Joyer, P.; Martin, G.; Rax, J.M.

    1989-01-01

    The lack of energy of runaway electrons, confined in Tore Supra tokamak, is studied. Ohmic discharges, obtained with helium gas, exhibit a small amount of runaway electrons on both hard X-ray monitors and neutron sensors. The observations show an important lack of energy for runaway electrons confined in Tore Supra. It is assumed to be dued to a small pitch-angle scattering (a few degrees), and many candidates for this are compared: the strongest known one collisions seems not to be enough by an order of magnitude. Density and magnetic scans on Tore Supra are needed to discriminate between enhanced collisional scattering processes and purely magnetic phenomena

  9. Ripple losses during ICRF heating in Tore Supra

    International Nuclear Information System (INIS)

    Basiuk, V.; Eriksson, L.-G.; Bergeaud, V.; Chantant, M.; Martin, G.; Nguyen, F.; Reichle, R.; Vallet, J.C.; Delpeche, L.; Surle, F.

    2004-01-01

    The toroidal field coils in Tore Supra are supra-conducting, and their number is restricted to 18. As a result, the ripple is fairly large, about 7% at the plasma boundary. Tore Supra has consequently been equipped with dedicated ripple loss diagnostics, which has allowed ripple loss studies. This paper reports on the measurements made with these diagnostics and provides an analysis of the experimental results, comparing them with theoretical expectations whenever possible. Furthermore, the main heating source accelerating ions in Tore Supra is ion cyclotron resonance range of frequency (ICRF) heating, and the paper provides new information on the ripple losses of ICRF accelerated ions. (author)

  10. Snake studies on Tore Supra

    International Nuclear Information System (INIS)

    Cristofani, P.; Desgranges, C.; Garbet, X.; Geraud, A.; Gil, C.; Hoang, G.T.; Joffrin, E.; Pecquet, A.L.

    1995-01-01

    Snakes have been achieved after pellet injection in Tore Supra during ohmic as well as ICRH discharges as it has already been observed in other machines. On Tore Supra, high speed H 2 pellets were injected into D 2 plasmas under the specified experimental conditions, the matter is deposited in the centre and snakes are produced in 50% of the cases, but they are created on a second much more internal q=1 surface leading probably to a non monotonic current profile. The properties of the snake, induced current modification and the important role of the bootstrap current in the snake formation are described. (K.A.) 5 refs.; 7 figs

  11. Tornado-Shaped Curves

    Science.gov (United States)

    Martínez, Sol Sáez; de la Rosa, Félix Martínez; Rojas, Sergio

    2017-01-01

    In Advanced Calculus, our students wonder if it is possible to graphically represent a tornado by means of a three-dimensional curve. In this paper, we show it is possible by providing the parametric equations of such tornado-shaped curves.

  12. Tornado hazard model with the variation effects of tornado intensity along the path length

    International Nuclear Information System (INIS)

    Hirakuchi, Hiromaru; Nohara, Daisuke; Sugimoto, Soichiro; Eguchi, Yuzuru; Hattori, Yasuo

    2015-01-01

    Most of Japanese tornados have been reported near the coast line, where all of Japanese nuclear power plants are located. It is necessary for Japanese electric power companies to assess tornado risks on the plants according to a new regulation in 2013. The new regulatory guide exemplifies a tornado hazard model, which cannot consider the variation of tornado intensity along the path length and consequently produces conservative risk estimates. The guide also recommends the long narrow strip area along the coast line with the width of 5-10 km as a region of interest, although the model tends to estimate inadequate wind speeds due to the limit of application. The purpose of this study is to propose a new tornado hazard model which can be apply to the long narrow strip area. The new model can also consider the variation of tornado intensity along the path length and across the path width. (author)

  13. Reaping a Harvest of Hope - Continuum Magazine | NREL

    Science.gov (United States)

    Reaping a Harvest of Hope On May 4, 2007, an EF-5 tornado-the highest rating of tornados-tore Reaping a Harvest of Hope Five years after a devastating tornado, Greensburg, Kansas, has new energy and a city also relied on NREL's life-cycle cost analysis and its extensive energy project development and

  14. Generation of missiles by tornadoes

    International Nuclear Information System (INIS)

    1974-11-01

    Available data on tornado wind velocities and wind distribution are incorporated into a mathematical model of the tornado wind field. The mathematical model is then used to predict the time-history of motion of a potential missile in a tornado wind field. (U.S.)

  15. Pneumonia cases following an EF-5 tornado.

    Science.gov (United States)

    Forshee-Hakala, Beth A

    2015-07-01

    Infections following a natural disaster such as an EF-5 tornado can be atypical and difficult to treat. Studies have looked at illness following several natural disasters, but few have studied respiratory illness following a tornado. A review of patients with pneumonia admitted during the period from May 22, 2009, through May 21, 2012, was completed. The Tornado Zone Group included adult patients who lived or worked in the tornado zone during the year following the tornado. Data were isolated by number of pneumonia cases within and outside the tornado zone per month per year. An analysis of variance comparing the number of pneumonia cases from the tornado zone per month per year was significant at F2,38 = 12.93 and P Tornado Zone Group (P Tornado Zone patients to be younger than controls (t390 = 5.14; P Tornado Zone Group included uncommon pathogens not isolated during the 2 years prior. The number of pneumonia cases may increase following tornadoes. Although current guidelines recommend narrow-spectrum antibiotics for community-acquired pneumonia, results of this study suggest the possible need for broader antimicrobial coverage after tornadoes. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. What's Left After a Tornado.

    Science.gov (United States)

    Lawrence Inst. of Tech., Southfield, MI.

    Following recent tornadoes, terms of specially trained architectural and engineering faculty conducted onsite examinations and research of building damage. It was concluded that tornado damage to buildings is predictable. A trained architect or engineer can establish, before a tornado strikes, those portions of the building that will offer the…

  17. Ciel, a new breath for Tore Supra

    International Nuclear Information System (INIS)

    Garin, P.

    1998-01-01

    In view of preparing next generation of tokamaks, a new goal has been given to Tore Supra, initially designed for 30 second operation. In order to fulfill this target, with the ultimate aim of injecting in the plasma 25 MW for 1000 s shots: all existing components (including the 6 ergodic divertor modules) present inside the inner vessel of Tore Supra will be removed by the end of 1999, they will be replaced in 2000 by a set of up to date technology components, designed to withstand an overall power of 25 MW for shots up to 1000 s constituting the so-called 'CIEL' project (French acronym for 'Composants Internes Et Limiteur'). It is planned to stop present Tore Supra's operation in autumn 1999, and start again with CIEL environment at the end of 2000. Full capacity (pumping and cooling) will be available in 2002. (author)

  18. Runaway electrons dynamics and confinement in TORE-SUPRA

    International Nuclear Information System (INIS)

    Chatelier, M.; Geraud, A.; Joyer, P.; Martin, G.; Rax, J.M.

    1989-01-01

    Ohmic discharges in TORE-SUPRA are sufficiently long (∼ 6 s) for runaway electrons (R.E.) to reach a steady energy state: their energy limit is determined by the balance between parallel electric field acceleration (20 MeV/V.s in TORE-SUPRA) and radiation losses due to the curvature of the trajectories. When R.E. energy is supposed to be only parallel, this provides estimate of order of 70 MeV (value usually called 'synchrotron limit') reached in less than 2 seconds. Experimental observations on TORE-SUPRA of photoneutron emission together with residual induced radioactivity in the first wall components tend to prove that the actual value is much lower than 70 MeV (i.e. 15-35 MeV). Earlier observations in ORMAK, PLT and TFR already showed R.E. energy a slightly less than expected from standard loop voltage acceleration calculations. Explanations given for this lack of energy (as skin-effect lowering the electric field during the ramp-up phase or balance between continuous creation and losses) seems not to hold on TORE-SUPRA and therefore another mechanism must be considered to explain the R.E. energy limitation. 4 refs., 2 figs

  19. Remote experiment participation on Tore-Supra

    International Nuclear Information System (INIS)

    Theis, J.-M.; Larsen, J.-M.

    2004-01-01

    The DRFC has traditionally had a very large external collaboration involvement. In particular, 15% of the DRFC work is directed towards the JET programme. As a consequence substantial telecommunications facilities have been installed [F.E.D. 60/3 (2002) 449; F.E.D. 60/3 (2002) 459]. A specific station for remote communication has been set up in the Tore-Supra control room, closely coupled to a collaborating team at INRS Que., Canada. This paper describes our pilot experience with the Canadian participation, which gives details of the communication and data sharing tools used to fully work on Tore-Supra

  20. Climatological and regional characteristics of supercell tornado occurrence based on a long-term reanalysis of tornado parameters

    International Nuclear Information System (INIS)

    Sugimoto, Soichiro; Nohara, Daisuke; Hirakuchi, Hiromaru

    2016-01-01

    This study investigates tornado climatology in Japan in terms of the regionalization of tornado intensity. A 50-year reanalysis dataset (the horizontal resolution of 5 km and hourly interval), produced by downscaling using the WRF mesoscale model and ECMWF reanalysis datasets, is used to estimate tornado parameters such as convective available potential energy (CAPE) and 3-km storm relative helicity (SReH). Energy helicity index (EHI) is also calculated as a composite parameter. Based on a long-term reanalysis data of tornado parameters, the number of times simultaneously exceeding threshold values is counted for SReH and CAPE parameters. The same procedure is done for EHI parameter. The thresholds are set from meteorological analysis of F3 tornadoes that are currently the most intense in Japan. Results indicate that the Pacific side of Japan along the south coast is the most favorable region for the occurrence of the most intense scale of tornado. This is consistent with the fact that the paths of most of all F3 tornadoes are include in this high-frequency region in exceeding thresholds. In other hand, approximately one-order smaller frequency in exceeding than the Pacific sides is evaluated in the Japan Sea side, which suggests topographic effects of blocking humid unstable air mass transported from the Pacific Ocean. The tornado intensity region evaluated by our approach is useful for a probabilistic hazard analysis of tornado wind speeds in the implementation of impact assessment of tornadoes for nuclear power plants. (author)

  1. Towards high-power long-pulse operation on Tore Supra

    International Nuclear Information System (INIS)

    2000-01-01

    The Tore Supra tokamak was given the main mission to investigate the route towards long pulse plasma discharges. This includes the problem of heat exhaust and particle control (via the development of high-performance plasma facing components), and in parallel the physics of fully non inductive discharges and its optimization with respect to the confinement. Tore Supra is thus equipped with a superconducting toroidal magnet (maximum magnetic field on axis 4.5T), a full set of actively cooled plasma facing components (PFC), and a heating and current drive capability based on high power RIF systems connected to actively cooled antennas. The encouraging results already obtained, as well as recent progress in PFC, allowed us to envisage a significant improvement in the heat exhaust capability of Tore Supra. The so-called CIEL-project consists in a complete upgrade of the inner chamber of Tore Supra, planned to be installed during the year 2000. The present paper deals with the experimental and modeling activity linked to the preparation of the long-pulse high-power discharges using the present Tore Supra equipment: heating and current drive scenarios, power coupling, confinement and transport studies, discharge control... An overview of the results obtained in that field is presented, as well as the progress required in the coming years, and the expected performance, for the CIEL phase, in terms of current drive and confinement. (author)

  2. Annihilation and Reanimation of a Tornado in the Improved Tornado Tube

    Science.gov (United States)

    Bednarek, Stanislaw

    2016-01-01

    Some new experiments using an improved version of the "tornado tube" are described here. The improved tornado tube consists of two plastic transparent bottles whose openings are connected with a ball valve, available at most hardware stores. After being filled with fluid and inverting, this tube allows demonstration of the generation,…

  3. The acquisition system for Tore Supra 1000 s discharges

    International Nuclear Information System (INIS)

    Guillerminet, B.; How, J.

    2000-01-01

    Long duration discharges are planned for Tore Supra in the near future. A study has been made to detect and correct all the possible limitations of the data acquisition system. Results and analysis of a few 1000 s 'dry-run' test pulses are presented in this paper as well as the solutions foreseen for Tore Supra

  4. Genesis of tornadoes associated with hurricanes

    Science.gov (United States)

    Gentry, R. C.

    1983-01-01

    The climatological history of hurricane-tornadoes is brought up to date through 1982. Most of the tornadoes either form near the center of the hurricane, from the outer edge of the eyewall outward, or in an area between north and east-southeast of the hurricane center. The blackbody temperatures of the cloud tops which were analyzed for several hurricane-tornadoes that formed in the years 1974, 1975, and 1979, did not furnish strong precursor signals of tornado formation, but followed one of two patterns: either the temperatures were very low, or the tornado formed in areas of strong temperature gradients. Tornadoes with tropical cyclones most frequently occur at 1200-1800 LST, and although most are relatively weak, they can reach the F3 intensity level. Most form in association with the outer rainbands of the hurricane.

  5. New developments on Tore Supra data acquisition units

    International Nuclear Information System (INIS)

    Leroux, F.; Caulier, G.; Ducobu, L.; Goniche, M.; Antar, G.

    2012-01-01

    The Tore Supra data acquisition system (DAS) was designed in the early eighties and has considerably evolved since then. Three generations of data acquisition units still coexist. As cost and maintenance of different operating systems is expensive, it was decided to explore an alternative solution based on an open source operating system (OS) with a disk-less system for the fourth generation. In 2010, Linux distributions for VME bus and PCI bus systems have been evaluated and compared to Lynx OS TM real time OS. The results obtained allowed to choose a version of Linux for VME and PC platform for DAS on Tore Supra. In 2011, the Tore Supra DAS dedicated software was ported on a Linux disk-less PCI platform. The new generation was successfully tested during real plasma experiments on one diagnostic, called DCEDRE. (authors)

  6. Assessing a Tornado Climatology from Global Tornado Intensity Distributions

    OpenAIRE

    Feuerstein, B.; Dotzek, N.; Grieser, J.

    2005-01-01

    Recent work demonstrated that the shape of tornado intensity distributions from various regions worldwide is well described by Weibull functions. This statistical modeling revealed a strong correlation between the fit parameters c for shape and b for scale regardless of the data source. In the present work it is shown that the quality of the Weibull fits is optimized if only tornado reports of F1 and higher intensity are used and that the c–b correlation does indeed reflect a universal featur...

  7. Nuclear fusion TORE SUPRA, a new stage

    International Nuclear Information System (INIS)

    Gregoire, M.; Laurent, L.

    1995-01-01

    Since almost forty years, the scientists try and neutralize in a pacific aim thermonuclear fusion energy and therefore they use the magnetic confinement of hot plasmas.In France, since 1960 the achieved studies permitted in 1988 to bring into service the TORE SUPRA TOKAMAK, which used, for the first time a superconducting magnet to generate the confinement magnetic field. TORE SUPRA, which didn't still explore its maximal potentialities, will be one of the apparatuses which will be used as basis of the international project ITER development. 5 figs

  8. Numerical Simulation of a Tornado Generating Supercell

    Science.gov (United States)

    Proctor, Fred H.; Ahmad, Nashat N.; LimonDuparcmeur, Fanny M.

    2012-01-01

    The development of tornadoes from a tornado generating supercell is investigated with a large eddy simulation weather model. Numerical simulations are initialized with a sounding representing the environment of a tornado producing supercell that affected North Carolina and Virginia during the Spring of 2011. The structure of the simulated storm was very similar to that of a classic supercell, and compared favorably to the storm that affected the vicinity of Raleigh, North Carolina. The presence of mid-level moisture was found to be important in determining whether a supercell would generate tornadoes. The simulations generated multiple tornadoes, including cyclonic-anticyclonic pairs. The structure and the evolution of these tornadoes are examined during their lifecycle.

  9. The tornado risk in eastern Canada

    International Nuclear Information System (INIS)

    Asmis, G.J.K.

    1980-01-01

    In the United States, a tornado design requirement was imposed on nuclear power plants in 1967. This requirement precipitated considerable study on the probability of toronado strikes and the consequent damage. As a data base, records of thousands of tornadoes which occurred in the U.S. in the last 50 years were available. Unfortunately, no such data base exists for tornadoes and other extreme atmospheric events in Canada. A theoretical study employing a Monte Carlo technique was used to simulate the tornado environment for a hypothetical site. This exercise concluded that a site the size of a large nuclear park such as Bruce can be traversed by a tornado every 500 years. The results are very preliminary since very little Canadian data or meteorological considerations have been involved. The results do, however, show that the frequency of a tornado strike is in the order of 10 -3 events/annum and is therefore of concern in the safety assessment of nuclear facilities. (auth)

  10. Water leak localization and recovery in Tore Supra

    International Nuclear Information System (INIS)

    Martinez, A.; Samaille, F.; Chantant, M.; Hatchressian, J.C.

    2007-01-01

    For almost 20 years at Tore Supra, plasma facing components (PFCs) are actively cooled by a pressurized water primary loop. Tore Supra can be considered as ITER relevant on this particular aspect. During plasma operation, it happened, that unexpected localized power deposits damaged a PFC leading to more or less large water leaks in the vacuum vessel. The improvement of the procedure to localize the leaky circuits, the investigation of technical solutions for minimizing the amount of water from steam condensation in the vacuum vessel and the optimisation of the quality of the draining and the drying of Tore Supra cooling loop circuits are the result of the experience gained during several years by the analysis of the water leak from plasma facing components (PFCs) and their consequences. Different new specific systems designed and installed during this year to fulfil these objectives are described in this paper

  11. Tornado protection by venting

    International Nuclear Information System (INIS)

    Cavanagh, C.A.

    1987-01-01

    The purpose of this paper is to demonstrate the ability to protect a modern nuclear power plant from the effects of a tornado by the use of a system of venting in all safety-related structures outside of the containment. The paper demonstrates this by presenting a method of analysis and of equipment selection that fully complies with the intent and the letter of applicable federal regulatory guides. A report of an actual tornado in the City of Kalamazoo, Michigan, suggests that the concept of sealing a plant during a tornado may not always be applicable

  12. Mexico tornado climatology

    Directory of Open Access Journals (Sweden)

    Manuel Macías Medrano

    2013-07-01

    Full Text Available A brief introduction on some features of tornado database in Mexico is exposed showing its substantive criteria. We resent a brief analysis about main Mexican tornadoes´ characteristics, based on data collected between 2000 to 2010, talking about spatial and temporal expressions (historical, seasonal and horary in order to show the importance of it destruction capacity and also the people´s vulnerability in Mexico.

  13. Pellet injection requirements for TORE SUPRA

    International Nuclear Information System (INIS)

    Lafferranderie, J.

    1986-01-01

    The main parameters of TORE SUPRA are outlined and pellet injection requirements to meet plasma density goals are discussed. Topics considered include plasma buildup, plasma refueling and penetration depth

  14. Kinetic Energy of Tornadoes in the United States.

    Directory of Open Access Journals (Sweden)

    Tyler Fricker

    Full Text Available Tornadoes can cause catastrophic destruction. Here total kinetic energy (TKE as a metric of destruction is computed from the fraction of the tornado path experiencing various damage levels and a characteristic wind speed for each level. The fraction of the path is obtained from a model developed for the Nuclear Regulatory Commission that combines theory with empirical data. TKE is validated as a useful metric by comparing it to other indexes and loss indicators. Half of all tornadoes have TKE exceeding 62.1 GJ and a quarter have TKE exceeding 383.2 GJ. One percent of the tornadoes have TKE exceeding 31.9 TJ. April has more energy than May with fewer tornadoes; March has more energy than June with half as many tornadoes. September has the least energy but November and December have the fewest tornadoes. Alabama ranks number one in terms of tornado energy with 2.48 PJ over the period 2007-2013. TKE can be used to help better understand the changing nature of tornado activity.

  15. Kinetic Energy of Tornadoes in the United States.

    Science.gov (United States)

    Fricker, Tyler; Elsner, James B

    2015-01-01

    Tornadoes can cause catastrophic destruction. Here total kinetic energy (TKE) as a metric of destruction is computed from the fraction of the tornado path experiencing various damage levels and a characteristic wind speed for each level. The fraction of the path is obtained from a model developed for the Nuclear Regulatory Commission that combines theory with empirical data. TKE is validated as a useful metric by comparing it to other indexes and loss indicators. Half of all tornadoes have TKE exceeding 62.1 GJ and a quarter have TKE exceeding 383.2 GJ. One percent of the tornadoes have TKE exceeding 31.9 TJ. April has more energy than May with fewer tornadoes; March has more energy than June with half as many tornadoes. September has the least energy but November and December have the fewest tornadoes. Alabama ranks number one in terms of tornado energy with 2.48 PJ over the period 2007-2013. TKE can be used to help better understand the changing nature of tornado activity.

  16. Tore Supra: technical description

    International Nuclear Information System (INIS)

    1985-08-01

    Cryogenic system of Tore Supra is described with its principal functions and operation modes. Data control and acquisition with on line data processing is presented. Radiation dose and induced radioactivity evaluation is studied. Cooling system is detailed together with characteristics of facilities and circuits to cool. Then machine assembly and buildings are presented [fr

  17. Characteristics of tornado generated missiles

    International Nuclear Information System (INIS)

    Bhattacharyya, A.K.; Boritz, R.C.; Niyogi, P.K.

    1975-10-01

    The development of techniques designed to calculate tornado missile velocities is traced. It is shown that there is a need for a consistent method for obtaining missile velocities for a variety of tornado parameters. A consistent method for determination of trajectories and velocities of missiles generated by a tornado is described. The effects of plant layout upon missile impact velocity at a given building are discussed from the point of view of determining the necessary missile barrier characteristics. 19 references

  18. Particle control studies on Tore Supra

    International Nuclear Information System (INIS)

    Mioduszewski, P.

    1987-01-01

    The report consists of viewgraphs. The goal of the particle control program at Tore Supra is to study plasma performance with strong pellet fueling and corresponding particle exhaust in a limiter tokamak

  19. Apparent Solar Tornado-Like Prominences

    Science.gov (United States)

    Panasenco, Olga; Martin, Sara F.; Velli, Marco

    2014-02-01

    Recent high-resolution observations from the Solar Dynamics Observatory (SDO) have reawakened interest in the old and fascinating phenomenon of solar tornado-like prominences. This class of prominences was first introduced by Pettit ( Astrophys. J. 76, 9, 1932), who studied them over many years. Observations of tornado prominences similar to the ones seen by SDO had already been documented by Secchi ( Le Soleil, 1877). High-resolution and high-cadence multiwavelength data obtained by SDO reveal that the tornado-like appearance of these prominences is mainly an illusion due to projection effects. We discuss two different cases where prominences on the limb might appear to have a tornado-like behavior. One case of apparent vortical motions in prominence spines and barbs arises from the (mostly) 2D counterstreaming plasma motion along the prominence spine and barbs together with oscillations along individual threads. The other case of apparent rotational motion is observed in a prominence cavity and results from the 3D plasma motion along the writhed magnetic fields inside and along the prominence cavity as seen projected on the limb. Thus, the "tornado" impression results either from counterstreaming and oscillations or from the projection on the plane of the sky of plasma motion along magnetic-field lines, rather than from a true vortical motion around an (apparent) vertical or horizontal axis. We discuss the link between tornado-like prominences, filament barbs, and photospheric vortices at their base.

  20. A Statistical Model for Regional Tornado Climate Studies.

    Science.gov (United States)

    Jagger, Thomas H; Elsner, James B; Widen, Holly M

    2015-01-01

    Tornado reports are locally rare, often clustered, and of variable quality making it difficult to use them directly to describe regional tornado climatology. Here a statistical model is demonstrated that overcomes some of these difficulties and produces a smoothed regional-scale climatology of tornado occurrences. The model is applied to data aggregated at the level of counties. These data include annual population, annual tornado counts and an index of terrain roughness. The model has a term to capture the smoothed frequency relative to the state average. The model is used to examine whether terrain roughness is related to tornado frequency and whether there are differences in tornado activity by County Warning Area (CWA). A key finding is that tornado reports increase by 13% for a two-fold increase in population across Kansas after accounting for improvements in rating procedures. Independent of this relationship, tornadoes have been increasing at an annual rate of 1.9%. Another finding is the pattern of correlated residuals showing more Kansas tornadoes in a corridor of counties running roughly north to south across the west central part of the state consistent with the dryline climatology. The model is significantly improved by adding terrain roughness. The effect amounts to an 18% reduction in the number of tornadoes for every ten meter increase in elevation standard deviation. The model indicates that tornadoes are 51% more likely to occur in counties served by the CWAs of DDC and GID than elsewhere in the state. Flexibility of the model is illustrated by fitting it to data from Illinois, Mississippi, South Dakota, and Ohio.

  1. Mathematical modeling of tornadoes and squall storms

    Directory of Open Access Journals (Sweden)

    Sergey A. Arsen’yev

    2011-04-01

    Full Text Available Recent advances in modeling of tornadoes and twisters consist of significant achievements in mathematical calculation of occurrence and evolution of a violent F5-class tornado on the Fujita scale, and four-dimensional mathematical modeling of a tornado with the fourth coordinate time multiplied by its characteristic velocity. Such a tornado can arise in a thunderstorm supercell filled with turbulent whirlwinds. A theory of the squall storms is proposed. The squall storm is modeled by running perturbation of the temperature inversion on the lower boundary of cloudiness. This perturbation is induced by the action of strong, hurricane winds in the upper and middle troposphere, and looks like a running solitary wave (soliton; which is developed also in a field of pressure and velocity of a wind. If a soliton of a squall storm gets into the thunderstorm supercell then this soliton is captured by supercell. It leads to additional pressure fall of air inside a storm supercell and stimulate amplification of wind velocity here. As a result, a cyclostrophic balance inside a storm supercell generates a tornado. Comparison of the radial distribution of wind velocity inside a tornado calculated by using the new formulas and equations with radar observations of the wind velocity inside Texas Tornado Dummit in 1995 and inside the 3 May 1999 Oklahoma City Tornado shows good correspondence.

  2. Heat loads on Tore Supra ICRF Launchers Plasma Facing Components

    International Nuclear Information System (INIS)

    Bremond, S.; Colas, L.; Beaumont, B.; Chantant, M.; Goniche, M.; Mitteau, R.

    2005-01-01

    Understanding the heat loads on Ion Cyclotron Range of Frequency (ICRF) launchers plasma-facing components is a crucial task both for operating present tokamaks and for designing ITER ICRF launchers as these loads may limit the RF power coupling capability. Tore Supra facility is particularly well suited to take this issue. Parametric studies have been performed which enables to get an overall detailed picture of the different heat loads on several areas, pointing to different mechanisms at the origin of the heat power fluxes. It is found that the most critical items for Tore-Supra operation are localized heat loads on the Faraday screen top left corner and vertical edges. Warming up close to maximum temperature limit originally set for protection of the plasma-facing components is found of high power pulses, but no erosion was observed after detailed inspection of the launcher in Tore-Supra vessel. Yet, the associated heat loads could be limiting for Tore-Supra operation in the future, and some dedicated work is under progress to improve the understanding of these power fluxes, pointing out the importance of getting a better knowledge of particle flows in the scrape of layer

  3. Tore-Supra: a Tokamak with superconducting toroidal field coils

    International Nuclear Information System (INIS)

    Turck, B.

    1987-07-01

    Tore Supra is a tokamak under construction on the site of Cen Cadarache by the Euratom-CEA Association. The machine technology integrates all problems related to the fabrication and the operation of large superconducting coils and of the associated cryogenic system. Tore Supra will provide a significant experience to prepare the next generation of machines for plasma physics and controlled fusion. Tore Supra is specially designed to implement a large physics program. The superconducting coils make possible the study of plasma confinement in long pulses (more than 60s), the impurities and the stability, and the efficiency of additional heating sources (neutral particle beams and radio frequency heating). The opportunity is taken to recall the particular features and requirements of the superconducting coils of the large future tokamaks in order to point out the problems that have to be faced by any new material (superconducting or not)

  4. A Statistical Model for Regional Tornado Climate Studies.

    Directory of Open Access Journals (Sweden)

    Thomas H Jagger

    Full Text Available Tornado reports are locally rare, often clustered, and of variable quality making it difficult to use them directly to describe regional tornado climatology. Here a statistical model is demonstrated that overcomes some of these difficulties and produces a smoothed regional-scale climatology of tornado occurrences. The model is applied to data aggregated at the level of counties. These data include annual population, annual tornado counts and an index of terrain roughness. The model has a term to capture the smoothed frequency relative to the state average. The model is used to examine whether terrain roughness is related to tornado frequency and whether there are differences in tornado activity by County Warning Area (CWA. A key finding is that tornado reports increase by 13% for a two-fold increase in population across Kansas after accounting for improvements in rating procedures. Independent of this relationship, tornadoes have been increasing at an annual rate of 1.9%. Another finding is the pattern of correlated residuals showing more Kansas tornadoes in a corridor of counties running roughly north to south across the west central part of the state consistent with the dryline climatology. The model is significantly improved by adding terrain roughness. The effect amounts to an 18% reduction in the number of tornadoes for every ten meter increase in elevation standard deviation. The model indicates that tornadoes are 51% more likely to occur in counties served by the CWAs of DDC and GID than elsewhere in the state. Flexibility of the model is illustrated by fitting it to data from Illinois, Mississippi, South Dakota, and Ohio.

  5. Three scales of motions associated with tornadoes

    International Nuclear Information System (INIS)

    Forbes, G.S.

    1978-03-01

    This dissertation explores three scales of motion commonly associated with tornadoes, and the interaction of these scales: the tornado cyclone, the tornado, and the suction vortex. The goal of the research is to specify in detail the character and interaction of these scales of motion to explain tornadic phenomena

  6. Solar Magnetized Tornadoes: Rotational Motion in a Tornado-like Prominence

    Science.gov (United States)

    Su, Yang; Gömöry, Peter; Veronig, Astrid; Temmer, Manuela; Wang, Tongjiang; Vanninathan, Kamalam; Gan, Weiqun; Li, YouPing

    2014-04-01

    Su et al. proposed a new explanation for filament formation and eruption, where filament barbs are rotating magnetic structures driven by underlying vortices on the surface. Such structures have been noticed as tornado-like prominences when they appear above the limb. They may play a key role as the source of plasma and twist in filaments. However, no observations have successfully distinguished rotational motion of the magnetic structures in tornado-like prominences from other motions such as oscillation and counter-streaming plasma flows. Here we report evidence of rotational motions in a tornado-like prominence. The spectroscopic observations in two coronal lines were obtained from a specifically designed Hinode/EIS observing program. The data revealed the existence of both cold and million-degree-hot plasma in the prominence leg, supporting the so-called prominence-corona transition region. The opposite velocities at the two sides of the prominence and their persistent time evolution, together with the periodic motions evident in SDO/AIA dark structures, indicate a rotational motion of both cold and hot plasma with a speed of ~5 km s-1.

  7. Major progress on tore supra toward steady state operation of tokamaks

    International Nuclear Information System (INIS)

    Saoutic, Y.

    2003-01-01

    During winter 2000-2001, a major upgrade of the internal components of Tore Supra has been completed that increased the heat extraction capability to 25 MW in steady state. Operating Tore Supra in this new configuration has produced a wealth of new results. The highlights of the 2002 long duration discharges campaign are: 4 minutes 25 seconds long discharges with an integrated energy of 0.75 GJ, which is three time higher than the old Tore Supra world record; recharge of the primary transformer by Lower Hybrid Current Drive (LHCD) for about 1 minute; 4 minutes long LHCD pulses; 1 minute long Ion Cyclotron Resonant Heating (ICRH) pulse (0.11 GJ of ICRH injected energy). Beyond the quantitative step, significant qualitative progress in the steady state nature of the discharge has been accomplished: contrary to the situation in the old Tore Supra configuration, the plasma density is perfectly controlled by active pumping over the overall shot duration. The duration of Tore Supra discharges is sufficient to allow the complete diffusion of the resistive current. Surprising new physics is revealed in such discharges when approaching zero loop voltage. Slow central electron temperature oscillations have been observed in a variety of situations. Such oscillations are not likely to be linked to any MHD instabilities and probably results from an interplay between current profile shape, LHCD power deposition and transport. Analysis of the temperature gradient in the core region shows a very interesting behaviour and the normalised temperature gradient length is compared to the critical thresholds. Finally, the performance of heating and current drive systems and the observations made of the interior of Tore Supra after the long duration discharges campaign are reported. (author)

  8. SOLAR MAGNETIZED 'TORNADOES': RELATION TO FILAMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Su Yang; Veronig, Astrid; Temmer, Manuela [IGAM-Kanzelhoehe Observatory, Institute of Physics, University of Graz, Universitaetsplatz 5, A-8010 Graz (Austria); Wang Tongjiang [Department of Physics, Catholic University of America, Washington, DC 20064 (United States); Gan Weiqun, E-mail: yang.su@uni-graz.at [Key Laboratory of Dark Matter and Space Astronomy, Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China)

    2012-09-10

    Solar magnetized 'tornadoes', a phenomenon discovered in the solar atmosphere, appear as tornado-like structures in the corona but are rooted in the photosphere. Like other solar phenomena, solar tornadoes are a feature of magnetized plasma and therefore differ distinctly from terrestrial tornadoes. Here we report the first analysis of solar 'tornadoes' (two papers which focused on different aspects of solar tornadoes were published in the Astrophysical Journal Letters and Nature, respectively, during the revision of this Letter). A detailed case study of two events indicates that they are rotating vertical magnetic structures probably driven by underlying vortex flows in the photosphere. They usually exist as a group and are related to filaments/prominences, another important solar phenomenon whose formation and eruption are still mysteries. Solar tornadoes may play a distinct role in the supply of mass and twists to filaments. These findings could lead to a new explanation of filament formation and eruption.

  9. Changing volatility of U.S. annual tornado reports

    Science.gov (United States)

    Tippett, Michael K.

    2014-10-01

    United States (U.S.) tornado activity results in substantial loss of life and property damage each year. A simple measure of the U.S. tornado climatology is the average number of tornadoes per year. However, even this statistic is elusive because of nonstationary behavior due in large part to changes in reporting practices. Differencing of the annual report data results in a quantity without mean trends and whose standard deviation we denote as volatility, since it is an indication of the likely year-to-year variation in the number of tornadoes reported. While volatility changes detected prior to 2000 can be associated with known reporting practice changes, an increase in volatility in the 2000s across intensity levels cannot. A volatility increase is also seen in a tornado environment index which measures the favorability of atmospheric conditions to tornado activity, providing evidence that the recent increase in tornado report volatility is related to the physical environment.

  10. Dispersion of small particles in a tornado

    International Nuclear Information System (INIS)

    Pepper, D.W.

    1975-05-01

    Based on 22 years of tornado statistics for South Carolina and Georgia, the probability of a tornado of Class F3 or greater striking a point at the Savannah River Plant is calculated to be approximately 14 x 10 -5 per year. These statistics show that Class F3 tornados (0.56-psi pressure drop and winds of 158 to 206 mph), are the most frequently occurring but cause only 23 percent of the damage compared with all classes of tornadoes. F4 tornadoes (1.10-psi pressure drop and winds of 207 to 260 mph) constitute only 20 percent of the total, but cause 63 percent of the damage. A Gaussian diffusion model is used to calculate the ground level concentration (ratio of concentration to source mass chi/Q) as a function of distance downwind should a tornado strike a point within the Savannah River Plant (SRP). The particles released to the atmosphere are assumed to be 1 to 3-μm diameter. For the calculations, two cases of possible small particle pickup are considered. In Case I a unit source of small particles is assumed to be injected into the tornado core and transported into the thunderstorm. In Case II, the cluster of particles is assumed to exit the side of the tornado core below the thunderstorm cloud. Several different stabilization heights within the thunderstorm, different horizontal wind speeds, and different turbulence dissipation rates are assumed for the calculations. (U.S.)

  11. ARE GIANT TORNADOES THE LEGS OF SOLAR PROMINENCES?

    Energy Technology Data Exchange (ETDEWEB)

    Wedemeyer, Sven; Scullion, Eamon; Rouppe van der Voort, Luc; Bosnjak, Antonija [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Antolin, Patrick, E-mail: sven.wedemeyer@astro.uio.no [Centre for Mathematical Plasma Astrophysics, Department of Mathematics, KU Leuven, Celestijnenlaan 200B, bus 2400, B-3001 Leuven (Belgium)

    2013-09-10

    Observations in the 171 A channel of the Atmospheric Imaging Assembly of the space-borne Solar Dynamics Observatory show tornado-like features in the atmosphere of the Sun. These giant tornadoes appear as dark, elongated, and apparently rotating structures in front of a brighter background. This phenomenon is thought to be produced by rotating magnetic field structures that extend throughout the atmosphere. We characterize giant tornadoes through a statistical analysis of properties such as spatial distribution, lifetimes, and sizes. A total number of 201 giant tornadoes are detected in a period of 25 days, suggesting that, on average, about 30 events are present across the whole Sun at a time close to solar maximum. Most tornadoes appear in groups and seem to form the legs of prominences, thus serving as plasma sources/sinks. Additional H{alpha} observations with the Swedish 1 m Solar Telescope imply that giant tornadoes rotate as a structure, although they clearly exhibit a thread-like structure. We observe tornado groups that grow prior to the eruption of the connected prominence. The rotation of the tornadoes may progressively twist the magnetic structure of the prominence until it becomes unstable and erupts. Finally, we investigate the potential relation of giant tornadoes to other phenomena, which may also be produced by rotating magnetic field structures. A comparison to cyclones, magnetic tornadoes, and spicules implies that such events are more abundant and short-lived the smaller they are. This comparison might help to construct a power law for the effective atmospheric heating contribution as a function of spatial scale.

  12. ARE GIANT TORNADOES THE LEGS OF SOLAR PROMINENCES?

    International Nuclear Information System (INIS)

    Wedemeyer, Sven; Scullion, Eamon; Rouppe van der Voort, Luc; Bosnjak, Antonija; Antolin, Patrick

    2013-01-01

    Observations in the 171 Å channel of the Atmospheric Imaging Assembly of the space-borne Solar Dynamics Observatory show tornado-like features in the atmosphere of the Sun. These giant tornadoes appear as dark, elongated, and apparently rotating structures in front of a brighter background. This phenomenon is thought to be produced by rotating magnetic field structures that extend throughout the atmosphere. We characterize giant tornadoes through a statistical analysis of properties such as spatial distribution, lifetimes, and sizes. A total number of 201 giant tornadoes are detected in a period of 25 days, suggesting that, on average, about 30 events are present across the whole Sun at a time close to solar maximum. Most tornadoes appear in groups and seem to form the legs of prominences, thus serving as plasma sources/sinks. Additional Hα observations with the Swedish 1 m Solar Telescope imply that giant tornadoes rotate as a structure, although they clearly exhibit a thread-like structure. We observe tornado groups that grow prior to the eruption of the connected prominence. The rotation of the tornadoes may progressively twist the magnetic structure of the prominence until it becomes unstable and erupts. Finally, we investigate the potential relation of giant tornadoes to other phenomena, which may also be produced by rotating magnetic field structures. A comparison to cyclones, magnetic tornadoes, and spicules implies that such events are more abundant and short-lived the smaller they are. This comparison might help to construct a power law for the effective atmospheric heating contribution as a function of spatial scale

  13. Steady state operation and control experiments on Tore Supra

    International Nuclear Information System (INIS)

    Saint-Laurent, F.

    2000-01-01

    The main programme of the Tore Supra tokamak is to investigate the route towards long pulse plasma discharges. Tore Supra is thus equipped with a superconducting toroidal magnet, a full set of actively cooled plasma facing components, and a heating and current drive capability based on high power RF systems connected to actively cooled antennas. After pioneering investigations using the LHCD system alone (2 min and zero loop voltage discharges), recent efforts have concentrated on finding scenarios to couple the two RF heating systems in order to perform high power, long duration discharges. To this aim, 6.5 MW, 25 s as well as 4 MW, 60 s discharges have been successfully achieved. At these high power levels, the plasma-wall interaction becomes a critical issue, and recycling fluxes must be controlled to maintain density and to avoid plasma contamination. All these results contributed to the validation of the upgrade of the Tore Supra first wall components (CIEL project) scheduled for 2000. (author)

  14. Methods for tornado frequency calculation of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Haibin; Li Lin

    2012-01-01

    In order to take probabilistic safety assessment of nuclear power plant tornado attack event, a method to calculate tornado frequency of nuclear power plant is introduced based on HAD 101/10 and NUREG/CR-4839 references. This method can consider history tornado frequency of the plant area, construction dimension, intensity various along with tornado path and area distribution and so on and calculate the frequency of different scale tornado. (authors)

  15. Increased variability of tornado occurrence in the United States.

    Science.gov (United States)

    Brooks, Harold E; Carbin, Gregory W; Marsh, Patrick T

    2014-10-17

    Whether or not climate change has had an impact on the occurrence of tornadoes in the United States has become a question of high public and scientific interest, but changes in how tornadoes are reported have made it difficult to answer it convincingly. We show that, excluding the weakest tornadoes, the mean annual number of tornadoes has remained relatively constant, but their variability of occurrence has increased since the 1970s. This is due to a decrease in the number of days per year with tornadoes combined with an increase in days with many tornadoes, leading to greater variability on annual and monthly time scales and changes in the timing of the start of the tornado season. Copyright © 2014, American Association for the Advancement of Science.

  16. Risk factors for tornado injuries.

    Science.gov (United States)

    Eidson, M; Lybarger, J A; Parsons, J E; MacCormack, J N; Freeman, J I

    1990-12-01

    Tornadoes in North and South Carolina on 28 March 1984 caused 252 people to be injured seriously enough to require hospitalization and 59 to be killed. To evaluate risk factors, we gathered information on 238 (94%) of those hospitalized and 46 (78%) of those killed. Those hospitalized or deceased had statistically significantly more deep cuts, concussions, unconsciousness and broken bones than those with them at the time of the tornado who were not hospitalized or killed. People living in mobile homes were more likely to be hospitalized or die than people occupying conventional houses. Other risk factors for hospitalization or death included advanced age (60+ years), no physical protection (not having been covered with a blanket or other object), having been struck by broken window glass or other falling objects, home lifted off its foundation, collapsed ceiling or floor, or walls blown away. More awareness of the tornado risk before it strikes and better adherence to tornado protection guidelines could reduce injuries and deaths in the future.

  17. Tornado Strikes Southern Maryland

    Science.gov (United States)

    2002-01-01

    Evening light catches the tops of towering thunderheads over the Mid-Atlantic states on April 28, 2002. The powerful storms spawned several tornados, one of which was classified as an F4 tornado. The powerful tornado touched down in the southern Maryland town of La Plata, destroying most of the historic downtown. The twister-one of the strongest ever to hit the state-beat a 24-mile swath running west to east through the state and claimed at least three lives. The image above was taken by the Geostationary Operational Environmental Satellite (GOES) at 7:15 PM Eastern Daylight Savings Time. A large version of the animation shows more detail. (5.9 MB Quicktime) Image courtesy National Oceanic and Atmospheric Administration (NOAA) and the GOES Project Science Office. Animation by Robert Simmon, NASA GSFC.

  18. Self-organization in the tornado: the new approach in the tornado description

    OpenAIRE

    Bystrai, G. P.; Lykov, I. A

    2012-01-01

    For the mathematical modeling of highly non-equilibrium and nonlinear processes in a tornado in this paper a new approach based on nonlinear equations of momentum transfer with function of sources and sinks is suggested. In constructing the model thermodynamic description is used, which is not entered before and allows discovering new principles of self-organization in a tornado. This approach gives fairly consistent physical results. This is an attempt to answer some fundamental questions co...

  19. Wind and tornado guidelines

    International Nuclear Information System (INIS)

    McDonald, J.R.

    1989-01-01

    The objective of the Department of Energy Natural Phenomena Hazards Project is to provide guidance and criteria for design of new facilities and for evaluation of existing ones subjected to extreme winds, earthquakes, and floods. This paper describes the treatment of wind and tornado hazards. Four facility-use categories are defined which represent increasing levels of risk to personnel or the environment in the event of a high wind event. Facilities are assigned to a particular category, depending on their mission, value, or toxic material content. The assigned facility-use category determines the design and evaluation criteria. The criteria are based on probabilistic hazard assessment. Performance goals are also specified for each facility-use category. A uniform approach to design wind loads, based on the ANSI A58.1-1982 standard, allows treatment of high winds and hurricane and tornado winds in a similar manner. Based on the wind hazard models, some sites must account for the possibility of tornadoes while others do not. Atmospheric pressure changes and missiles must be taken into account when considering tornadoes. The design and evaluation guidelines are designed to establish consistent levels of risk for different natural phenomena hazards and for facilities at different geographical locations

  20. Tornado-borne missile speeds. Final report

    International Nuclear Information System (INIS)

    Simiu, E.; Cordes, M.

    1976-04-01

    An investigation of the question of tornado-borne missile speeds was carried out, with a view to identify pertinent areas of uncertainty and to estimate credible tornado-borne missile speeds - within the limitations inherent in the present state of the art. The investigation consists of two parts: (1) a study in which a rational model for the missile motion is proposed, and numerical experiments are carried out corresponding to various assumptions on the initial conditions of the missile motion, the structure of the tornado flow, and the aerodynamic properties of the missile; (2) a theoretical and experimental study of tornado-borne missile aerodynamics, conducted by Colorado State Univ. (CSU) to be covered in a separate report by CSU. In the present report, the factors affecting missile motion and their influence upon such motion are examined

  1. SOLAR MAGNETIZED TORNADOES: ROTATIONAL MOTION IN A TORNADO-LIKE PROMINENCE

    Energy Technology Data Exchange (ETDEWEB)

    Su, Yang; Veronig, Astrid; Temmer, Manuela; Vanninathan, Kamalam [IGAM-Kanzelhöhe Observatory, Institute of Physics, University of Graz, Universitätsplatz 5, A-8010 Graz (Austria); Gömöry, Peter [Astronomical Institute of the Slovak Academy of Sciences, SK-05960 Tatranská Lomnica (Slovakia); Wang, Tongjiang [Department of Physics, the Catholic University of America, Washington, DC 20064 (United States); Gan, Weiqun; Li, YouPing, E-mail: yang.su@uni-graz.at [Key Laboratory of Dark Matter and Space Astronomy, Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China)

    2014-04-10

    Su et al. proposed a new explanation for filament formation and eruption, where filament barbs are rotating magnetic structures driven by underlying vortices on the surface. Such structures have been noticed as tornado-like prominences when they appear above the limb. They may play a key role as the source of plasma and twist in filaments. However, no observations have successfully distinguished rotational motion of the magnetic structures in tornado-like prominences from other motions such as oscillation and counter-streaming plasma flows. Here we report evidence of rotational motions in a tornado-like prominence. The spectroscopic observations in two coronal lines were obtained from a specifically designed Hinode/EIS observing program. The data revealed the existence of both cold and million-degree-hot plasma in the prominence leg, supporting the so-called prominence-corona transition region. The opposite velocities at the two sides of the prominence and their persistent time evolution, together with the periodic motions evident in SDO/AIA dark structures, indicate a rotational motion of both cold and hot plasma with a speed of ∼5 km s{sup –1}.

  2. SOLAR MAGNETIZED TORNADOES: ROTATIONAL MOTION IN A TORNADO-LIKE PROMINENCE

    International Nuclear Information System (INIS)

    Su, Yang; Veronig, Astrid; Temmer, Manuela; Vanninathan, Kamalam; Gömöry, Peter; Wang, Tongjiang; Gan, Weiqun; Li, YouPing

    2014-01-01

    Su et al. proposed a new explanation for filament formation and eruption, where filament barbs are rotating magnetic structures driven by underlying vortices on the surface. Such structures have been noticed as tornado-like prominences when they appear above the limb. They may play a key role as the source of plasma and twist in filaments. However, no observations have successfully distinguished rotational motion of the magnetic structures in tornado-like prominences from other motions such as oscillation and counter-streaming plasma flows. Here we report evidence of rotational motions in a tornado-like prominence. The spectroscopic observations in two coronal lines were obtained from a specifically designed Hinode/EIS observing program. The data revealed the existence of both cold and million-degree-hot plasma in the prominence leg, supporting the so-called prominence-corona transition region. The opposite velocities at the two sides of the prominence and their persistent time evolution, together with the periodic motions evident in SDO/AIA dark structures, indicate a rotational motion of both cold and hot plasma with a speed of ∼5 km s –1

  3. A step towards controlled fusion reactors: Tore Supra tokamak with superconducting magnets

    International Nuclear Information System (INIS)

    Turck, B.

    1988-01-01

    Tore Supra technology has to solve all the problems related to the development and the installaion of superconducting coils and associated cryogenic devices. Tore Supra will allow to get a significative experience to prepare next machines. Specifications and needs of tokamaks concerning the superconducting coils of future machines are recalled [fr

  4. Some New Ideas About Tornadoes

    Science.gov (United States)

    Weigel, Edwin P.

    1975-01-01

    Based on the assumption that if occupants of buildings knew which places in these buildings were relatively safe in disasters such as tornadoes, and if they had sufficient warning, architects and engineers feel there is a significant opportunity to advance the art of school (or building) design to provide tornado-protected areas. (EB)

  5. Modeling the Excitation of Seismic Waves by the Joplin Tornado

    Science.gov (United States)

    Valovcin, Anne; Tanimoto, Toshiro

    2017-10-01

    Tornadoes generate seismic signals when they contact the ground. Here we examine the signals excited by the Joplin tornado, which passed within 2 km of a station in the Earthscope Transportable Array. We model the tornado-generated vertical seismic signal at low frequencies (0.01-0.03 Hz) and solve for the strength of the seismic source. The resulting source amplitude is largest when the tornado was reported to be strongest (EF 4-5), and the amplitude is smallest when the tornado was weak (EF 0-2). A further understanding of the relationship between source amplitude and tornado intensity could open up new ways to study tornadoes from the ground.

  6. Lower hybrid current drive in Tore Supra and JET

    International Nuclear Information System (INIS)

    Moreau, D.; Gormezano, C.

    1991-01-01

    Recent Lower Hybrid Current Drive (LHCD) experiments in TORE SUPRA and JET are reported. Large multijunction launchers have allowed the coupling of 5MW to the plasma for several seconds with a maximum of 3.8 kW/cm 2 . Measurements of the scattering matrices of the antennae show good agreement with theory. The current drive efficiency in TORE SUPRA is about 0.2 x 10 20 Am -2 /W with LH power alone and reaches 0.4 x 10 20 Am -2 /W in JET thanks to a high volume-averaged electron temperature (1.9 keV) and also to a synergy between Lower Hybrid and Fast Magnetosonic Waves. At n e = 1.5 x 10 19 m -3 in TORE SUPRA, sawteeth are suppressed and m = 1MHD oscillations the frequency of which clearly depends on the amount of LH power are observed on soft X-rays, and also on non-thermal ECE. In Jet ICRH produced sawtooth free periods are extended by the application of LHCD and current profile broadening has been clearly observed consistent with off-axis fast electron populations. LH power modulation experiments performed in TORE SUPRA at n e = 4 x 10 19 m -3 show a delayed central electron heating despite the off-axis creation of suprathermal electrons, thus ruling out the possibility of a direct heating through central wave absorption. A possible explanation in terms of anomalous fast electron transport and classical slowing down would yield a diffusion coefficient of the order of 10 m 2 /s for the fast electrons. Finally, successful pellet fuelling of a partially LH driven plasma was obtained in TORE SUPRA, 28 successive pellets allowing the density to rise to n e = 4 x 10 19 m -3 . This could be achieved by switching the LH power off for 90 ms before each pellet injection, i.e. without modifying significantly the current density profile

  7. Lower hybrid current drive in Tore Supra and jet

    International Nuclear Information System (INIS)

    Moreau, D.; Gormezano, C.

    1991-07-01

    Recent Lower Hybrid Current Drive (LHCD) experiments in TORE SUPRA and JET are reported. Large multijunction launchers have allowed the coupling of 5 MW to the plasma for several seconds with a maximum of 3.8 kW/cm 2 . Measurements of the scattering matrices of the antennae show good agreement with theory. The current drive efficiency in TORE SUPRA is about 0.2 x 10 20 Am -2 /W with LH power alone and reaches 0.4 x 10 20 Am -2 /W in JET thanks to a high volume-averaged electron temperature (1.9 keV) and also to a synergy between Lower Hybrid and Fast Magnetosonic Waves. At average n e = 1.5 x 10 19 m -3 in TORE SUPRA, sawteeth are suppressed and m = 1 MHD oscillations the frequency of which clearly depends on the amount of LH power are observed on soft X-rays, and also on non-thermal ECE. In JET ICRH produced sawtooth-free periods are extended by the application of LHCD (2.9 s. with 4 MW ICRH) and current profile broadening has been clearly observed consistent with off-axis fast electron populations. LH power modulation experiments performed in TORE SUPRA at average n e = 4 x 10 19 m -3 show a delayed central electron heating despite the off-axis creation of suprathermal electrons, thus ruling out the possibility of a direct heating through central wave absorption. A possible explanation in terms of anomalous fast electron transport and classical slowing down would yield a diffusion coefficient of the order of 10 m 2 /s for the fast electrons. Other interpretations such as an anomalous heat pinch or a central confinement enhancement cannot be excluded. Finally, successful pellet fuelling of a partially LH driven plasma was obtained in TORE SUPRA, 28 successive pellets allowing the density to rise to average n e = 4 x 10 19 m -3 . This could be achieved by switching the LH power off for 90 ms before each pellet injection, i.e. without modifying significantly the current density profile

  8. Population and energy elasticity of tornado casualties

    Science.gov (United States)

    Fricker, Tyler; Elsner, James B.; Jagger, Thomas H.

    2017-04-01

    Tornadoes are capable of catastrophic destruction and mass casualties, but there are yet no estimates of how sensitive the number of casualties are to changes in the number of people in harm's way or to changes in tornado energy. Here the relationship between tornado casualties (deaths and injuries), population, and energy dissipation is quantified using the economic concept of "elasticity." Records of casualties from individual tornadoes over the period 2007-2015 are fit to a regression model. The coefficient on the population term (population elasticity) indicates that a doubling in population increases the casualty rate by 21% [(17, 24)%, 95% credible interval]. The coefficient on the energy term (energy elasticity) indicates that a doubling in energy dissipation leads to a 33% [(30, 35)%, 95% credible interval] increase in the casualty rate. The difference in elasticity values show that on average, changes in energy dissipation have been relatively more important in explaining tornado casualties than changes in population. Assuming no changes in warning effectiveness or mitigation efforts, these elasticity estimates can be used to project changes in casualties given the known population trends and possible trends in tornado activity.

  9. Steady-State Operation in Tore Supra

    Science.gov (United States)

    Hoang, G. T.; Tore Supra, Equipe

    1999-11-01

    The Tore Supra superconducting tokamak is devoted to steady-state operation. The CIEL (French acronym for internal component and limiter) project( LIPA, M., et al., Proc. of the 17th IEEE/NPSS Symp. on Fus. Engineering, San Diego, USA, 1997.) consists of a complete upgrade of the inner chamber of Tore Supra, planned to be installed during the year 2000. This project will allow physics scenarios with up to 24 MW of radio frequency heating and current drive (typically 8 - 10 MW of ICRF, 10 - 12 MW of LHCD and 2 MW of ECRF) in stationary plasmas up to 1000 s, with active particle control. This paper presents an overview of the experiments planned to explore the properties, such as the confinement and MHD stability, of various heating and current drive scenarios for long duration discharges. The expected performance for the CIEL phase is also reported.

  10. The probability of a tornado missile hitting a target

    International Nuclear Information System (INIS)

    Goodman, J.; Koch, J.E.

    1983-01-01

    It is shown that tornado missile transportation is a diffusion Markovian process. Therefore, the Green's function method is applied for the estimation of the probability of hitting a unit target area. This propability is expressed through a joint density of tornado intensity and path area, a probability of tornado missile injection and a tornado missile height distribution. (orig.)

  11. Infrasonic Emissions From A Tornado

    Science.gov (United States)

    Petrin, Christopher; Elbing, Brian

    2017-11-01

    Tornadoes cause dozens of deaths and significant damage throughout the United States every year. Tornado-producing storm systems emit infrasound (sound at frequencies below human hearing) up to 2 hours before tornadogenesis. Weak atmospheric attenuation at these frequencies allows them to be detected hundreds of miles away. Hence, passive infrasonic monitoring may be used for long-range study of tornadogenesis. This requires characterization of infrasound during the life of a tornado and from other background sources. This is being accomplished as part of the Collaboration Leading Operational UAS Development for Meteorology and Atmospheric Physics (CLOUD-MAP) project, a multi-university collaboration focused on the development and implementation of unmanned aerial systems (UAS) and their integration with sensors for atmospheric measurement. This presentation will report findings from a fixed infrasonic microphone that has been continuously monitoring the atmosphere since September 2, 2016. Infrasound from a tornado that occurred 19 km from the microphone on May 11, 2017 will be presented as well as an overview of other infrasonic observations. This work was supported by NSF Grant 1539070.

  12. Vorticity budget of a tornado-like vortex

    Energy Technology Data Exchange (ETDEWEB)

    Sassa, Koji; Takemura, Saki, E-mail: sassa@kochi-u.ac.jp [Department of Applied Science, Kochi University (Japan)

    2011-12-22

    We evaluated the vorticity budget of a tornado-like vortex by measuring vertical and horizontal circulations of it. Though spiral horizontal vortices are clearly observed to converge and tilted into the tornado-like vortex, their circulation is quite small. The conversion of the vertical vorticity concentrated at the side of the spiral horizontal vortices was found to mainly contribute to the maintenance of the tornado-like vortex.

  13. Impact assessment of tornado against nuclear power plant

    International Nuclear Information System (INIS)

    Sato, Daisuke

    2015-01-01

    The impact assessment of tornado against nuclear power plants conforms to the 'Assessment guide for tornado effect on nuclear power plants' stipulated by the Nuclear Regulation Authority. In face of the assessment, important items are the setting of the maximum wind speed considered in design, and the setting of a flying object evaluation model, on the basis of observation results. The Japan Society of Maintenology summarized the verification results of the concept on the setting of tornado design and flying object valuation model, the contents of which are explained here. The following are explained: (1) validity of the setting of tornado design in the Assessment Guide, (2) analysis of synoptic field, (3) study on the regional characteristics of tornado occurrence environmental field by means of the analysis of synoptic field and gust associated index, and (4) setting of tornado design based on the above (1)-(3). Next, on the flying object evaluation model, the authors picked up the Rankine vortex model and Fujita model, and verified the reproducibility of the models using the features of each and the actual state of tornado damage. (A.O.)

  14. Impact of tornadoes on hospital admissions for acute cardiovascular events.

    Science.gov (United States)

    Silva-Palacios, Federico; Casanegra, Ana Isabel; Shapiro, Alan; Phan, Minh; Hawkins, Beau; Li, Ji; Stoner, Julie; Tafur, Alfonso

    2015-11-01

    There is a paucity of data describing cardiovascular events after tornado outbreaks. We proposed to study the effects of tornadoes on the incidence of cardiovascular events at a tertiary care institution. Hospital admission records from a single center situated in a tornado-prone area three months before and after a 2013 tornado outbreak were abstracted. To control for seasonal variation, we also abstracted data from the same period of the prior year (control). Hospital admissions for cardiovascular events (CVEs) including acute myocardial infarction, stroke and venous thromboembolism (VTE) were summated by zip codes, and compared by time period. There were 22,607 admissions analyzed, of which 6,705 (30%), 7,980 (35%), and 7,922 (35%) were during the pre-tornado, post-tornado, and control time frames, respectively. There were 344 CVE in the controls, 317 CVE in pre-tornado and 364 CVEs in post tornado periods. There was no difference in the prevalence of CVE during the post-tornado season compared with the control (PPR=1.05 95% CI: 0.91 to 1.21, p=0.50) or the pre-tornado season (PPR=0.96, 95% CI: 0.83 to 1.21, p=0.63). In conclusion, tornado outbreaks did not increase the prevalence of cardiovascular events. In contrast to the effect of hurricanes, implementation of a healthcare policy change directed toward the early treatment and prevention of cardiovascular events after tornadoes does not seem warranted. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Rationale for reduced tornado design bases

    International Nuclear Information System (INIS)

    Rutherford, P.D.; Ho, H.W.; Hartung, J.A.; Kastenberg, W.E.

    1985-01-01

    This paper provides a rationale for relaxing the present NRC tornado design requirements, which are based on a design basis tornado (DBT) whose frequency of exceedance is 10 -7 per year. It is proposed that a reduced DBT frequency of 10 -5 to 10 -6 per year is acceptable. This change in the tornado design bases for LMFBRs (and possibly all types of nuclear plants) is justified based on (1) existing NRC regulations and guidelines, (2) probabilistic arguments, (3) consistency with NRC trial safety goals, and (4) cost-benefit analysis

  16. Magnetohydrodynamic Models of Molecular Tornadoes

    Science.gov (United States)

    Au, Kelvin; Fiege, Jason D.

    2017-07-01

    Recent observations near the Galactic Center (GC) have found several molecular filaments displaying striking helically wound morphology that are collectively known as molecular tornadoes. We investigate the equilibrium structure of these molecular tornadoes by formulating a magnetohydrodynamic model of a rotating, helically magnetized filament. A special analytical solution is derived where centrifugal forces balance exactly with toroidal magnetic stress. From the physics of torsional Alfvén waves we derive a constraint that links the toroidal flux-to-mass ratio and the pitch angle of the helical field to the rotation laws, which we find to be an important component in describing the molecular tornado structure. The models are compared to the Ostriker solution for isothermal, nonmagnetic, nonrotating filaments. We find that neither the analytic model nor the Alfvén wave model suffer from the unphysical density inversions noted by other authors. A Monte Carlo exploration of our parameter space is constrained by observational measurements of the Pigtail Molecular Cloud, the Double Helix Nebula, and the GC Molecular Tornado. Observable properties such as the velocity dispersion, filament radius, linear mass, and surface pressure can be used to derive three dimensionless constraints for our dimensionless models of these three objects. A virial analysis of these constrained models is studied for these three molecular tornadoes. We find that self-gravity is relatively unimportant, whereas magnetic fields and external pressure play a dominant role in the confinement and equilibrium radial structure of these objects.

  17. Magnetohydrodynamic Models of Molecular Tornadoes

    Energy Technology Data Exchange (ETDEWEB)

    Au, Kelvin; Fiege, Jason D., E-mail: fiege@physics.umanitoba.ca [Department of Physics and Astronomy, University of Manitoba Winnipeg, MB R3T 2N2 (Canada)

    2017-07-10

    Recent observations near the Galactic Center (GC) have found several molecular filaments displaying striking helically wound morphology that are collectively known as molecular tornadoes. We investigate the equilibrium structure of these molecular tornadoes by formulating a magnetohydrodynamic model of a rotating, helically magnetized filament. A special analytical solution is derived where centrifugal forces balance exactly with toroidal magnetic stress. From the physics of torsional Alfvén waves we derive a constraint that links the toroidal flux-to-mass ratio and the pitch angle of the helical field to the rotation laws, which we find to be an important component in describing the molecular tornado structure. The models are compared to the Ostriker solution for isothermal, nonmagnetic, nonrotating filaments. We find that neither the analytic model nor the Alfvén wave model suffer from the unphysical density inversions noted by other authors. A Monte Carlo exploration of our parameter space is constrained by observational measurements of the Pigtail Molecular Cloud, the Double Helix Nebula, and the GC Molecular Tornado. Observable properties such as the velocity dispersion, filament radius, linear mass, and surface pressure can be used to derive three dimensionless constraints for our dimensionless models of these three objects. A virial analysis of these constrained models is studied for these three molecular tornadoes. We find that self-gravity is relatively unimportant, whereas magnetic fields and external pressure play a dominant role in the confinement and equilibrium radial structure of these objects.

  18. Manufacture and mechanical test of a TORE SUPRA model coil

    International Nuclear Information System (INIS)

    Aymar, R.; Claudet, G.; Disdier, F.; Hamelin, J.; Libeyre, P.; Mayaux, G.; Meuris, C.; Parain, J.; Torossian, A.

    1980-09-01

    Inside the qualifying test programme, supporting the Tore Supra Design, a reduced scale model of a Bsub(T) coil was fabricated by a large industrial firm. This model coil is provided with the same features as those retained for the complete magnet. Tests of this model coil have been carried out in such a way that most of stresses which will arise in Tore Supra windings are simulated; simultaneously its cryogenic supply is fully representative of the system retained for the complete machine. Operation of the model coil has been found highly stable; under the conditions of applied field and forces a coil transition could be triggered, by an electrical heater located inside the coil, only when the temperature of the superfluid helium bath was close to Tsub(lambda). Thus, design and manufacturing techniques have been qualified satisfactorily to proceed to the next step: fabrication of the superconducting Bsub(T) coils of Tore Supra

  19. Towards operations on Tore Supra of an ITER relevant inspection robot and associated processes

    International Nuclear Information System (INIS)

    Gargiulo, L.; Cordier, J.J.; Friconneau, J.P.; Grisolia, C.; Palmer, J.D.; Perrot, Y.; Samaille, F.

    2007-01-01

    The aim of the project is to demonstrate on Tore Supra the reliability of a multi-purpose in-vessel remote handling inspection system using a long reach, limited payload carrier. The robot prototype is fully representative of the deployment carrier system that could be required on ITER. The demonstration on Tore Supra will help in the understanding of operation issues that could occur in the tokamak vacuum vessel equipped of actively cooled components. The viewing process that is currently under development will allow close inspection of the Tore Supra plasma facing components that are representative of the ITER divertor targets in terms of confined environment and identification of possible tiles failure of CFC carbon tiles. One of the other potential inspection processes that is foreseen to be tested using the AIA carrier in Tore Supra is the laser ablation system of the CFC armour. It could be fully relevant for the ITER wall detritiation issues. Such process can be simulated on Tore Supra through the deuterium inventory under long-time plasma discharges. The in situ leakage localisation of a damaged plasma facing component is also one of the major ITER maintenance challenges that could use remote handling inspection tools

  20. Towards operations on Tore Supra of an ITER relevant inspection robot and associated processes

    Energy Technology Data Exchange (ETDEWEB)

    Gargiulo, L. [Association Euratom-CEA, DSM/Departement de Recherche sur la Fusion Controlee, CEA/Cadarache, F-13108 Saint Paul Lez Durance Cedex (France)], E-mail: laurent.gargiulo@cea.fr; Cordier, J.J. [Association Euratom-CEA, DSM/Departement de Recherche sur la Fusion Controlee, CEA/Cadarache, F-13108 Saint Paul Lez Durance Cedex (France); Friconneau, J.P. [CEA-LIST Robotics and Interactive Systems Unit, BP6 F-92265 Fontenay aux Roses Cedex (France); Grisolia, C. [Association Euratom-CEA, DSM/Departement de Recherche sur la Fusion Controlee, CEA/Cadarache, F-13108 Saint Paul Lez Durance Cedex (France); Palmer, J.D. [EFDA CSU, Max-Planck-Institut fuer Plasma Physik Boltzmannstr. 2, D-85748 Garching (Germany); Perrot, Y. [CEA-LIST Robotics and Interactive Systems Unit, BP6 F-92265 Fontenay aux Roses Cedex (France); Samaille, F. [Association Euratom-CEA, DSM/Departement de Recherche sur la Fusion Controlee, CEA/Cadarache, F-13108 Saint Paul Lez Durance Cedex (France)

    2007-10-15

    The aim of the project is to demonstrate on Tore Supra the reliability of a multi-purpose in-vessel remote handling inspection system using a long reach, limited payload carrier. The robot prototype is fully representative of the deployment carrier system that could be required on ITER. The demonstration on Tore Supra will help in the understanding of operation issues that could occur in the tokamak vacuum vessel equipped of actively cooled components. The viewing process that is currently under development will allow close inspection of the Tore Supra plasma facing components that are representative of the ITER divertor targets in terms of confined environment and identification of possible tiles failure of CFC carbon tiles. One of the other potential inspection processes that is foreseen to be tested using the AIA carrier in Tore Supra is the laser ablation system of the CFC armour. It could be fully relevant for the ITER wall detritiation issues. Such process can be simulated on Tore Supra through the deuterium inventory under long-time plasma discharges. The in situ leakage localisation of a damaged plasma facing component is also one of the major ITER maintenance challenges that could use remote handling inspection tools.

  1. Science 101: What Causes Severe Thunderstorms and Tornadoes?

    Science.gov (United States)

    Robertson, Bill

    2016-01-01

    What causes severe thunderstorms and tornadoes? Tornadoes, often accompanied by severe thunderstorms and hail, form in pretty much the same way as severe thunderstorms. In the continental United States, tornadoes usually form in spring and summer, when warm, humid air from the Gulf of Mexico moves across the continent from southeast to northwest…

  2. Tornado intensity estimated from damage path dimensions.

    Science.gov (United States)

    Elsner, James B; Jagger, Thomas H; Elsner, Ian J

    2014-01-01

    The Newcastle/Moore and El Reno tornadoes of May 2013 are recent reminders of the destructive power of tornadoes. A direct estimate of a tornado's power is difficult and dangerous to get. An indirect estimate on a categorical scale is available from a post-storm survery of the damage. Wind speed bounds are attached to the scale, but the scale is not adequate for analyzing trends in tornado intensity separate from trends in tornado frequency. Here tornado intensity on a continuum is estimated from damage path length and width, which are measured on continuous scales and correlated to the EF rating. The wind speeds on the EF scale are treated as interval censored data and regressed onto the path dimensions and fatalities. The regression model indicates a 25% increase in expected intensity over a threshold intensity of 29 m s(-1) for a 100 km increase in path length and a 17% increase in expected intensity for a one km increase in path width. The model shows a 43% increase in the expected intensity when fatalities are observed controlling for path dimensions. The estimated wind speeds correlate at a level of .77 (.34, .93) [95% confidence interval] with a small sample of wind speeds estimated independently from a doppler radar calibration. The estimated wind speeds allow analyses to be done on the tornado database that are not possible with the categorical scale. The modeled intensities can be used in climatology and in environmental and engineering applications. Research is needed to understand the upward trends in path length and width.

  3. Tornado intensity estimated from damage path dimensions.

    Directory of Open Access Journals (Sweden)

    James B Elsner

    Full Text Available The Newcastle/Moore and El Reno tornadoes of May 2013 are recent reminders of the destructive power of tornadoes. A direct estimate of a tornado's power is difficult and dangerous to get. An indirect estimate on a categorical scale is available from a post-storm survery of the damage. Wind speed bounds are attached to the scale, but the scale is not adequate for analyzing trends in tornado intensity separate from trends in tornado frequency. Here tornado intensity on a continuum is estimated from damage path length and width, which are measured on continuous scales and correlated to the EF rating. The wind speeds on the EF scale are treated as interval censored data and regressed onto the path dimensions and fatalities. The regression model indicates a 25% increase in expected intensity over a threshold intensity of 29 m s(-1 for a 100 km increase in path length and a 17% increase in expected intensity for a one km increase in path width. The model shows a 43% increase in the expected intensity when fatalities are observed controlling for path dimensions. The estimated wind speeds correlate at a level of .77 (.34, .93 [95% confidence interval] with a small sample of wind speeds estimated independently from a doppler radar calibration. The estimated wind speeds allow analyses to be done on the tornado database that are not possible with the categorical scale. The modeled intensities can be used in climatology and in environmental and engineering applications. Research is needed to understand the upward trends in path length and width.

  4. Dual-Polarimetric Radar-Based Tornado Debris Signatures and Paths Associated with Tornadoes Over Northern Alabama During the Historic Outbreak of 27 April 2011

    Science.gov (United States)

    Carey, Lawrence D.; Schultz, Christopher J.; Schultz, Elise V.; Petersen, Walter A.; Gatlin, Patrick N.; Knupp, Kevin R.; Molthan, Andrew L.; Jedloved, Gary J.; Carcione, Brian C.; Darden, Christopher B.; hide

    2012-01-01

    A historic tornado and severe weather outbreak devastated much of the southeastern United States between 25 and 28 April 2011. On 27 April 2011, northern Alabama was particularly hard hit by 40 tornadoes, including 6 that reached EF-4 to EF-5 on the Enhanced Fujita damage scale. In northern Alabama alone, there were approximately 100 fatalities and hundreds of people who were injured or lost their homes during the havoc caused by these violent tornadic storms. Many of these tornadoes occurred within range of the University of Alabama in Huntsville (UAHuntsville) Advanced Radar for Meteorological and Operational Research (ARMOR, C-band dual-polarimetric). A unique capability of dual-polarimetric radar is the near-real time identification of lofted debris associated with ongoing tornadoes. The focus of this paper is to analyze the dual-polarimetric radar-inferred tornado debris signatures in 6 tornadoes in North Alabama on April 27, 2011. Several of these debris signatures were disseminated in real-time to the NWS Huntsville and local media to confirm storm spotter reports, confidence to enhance wording within warnings, and accurately pinpoint the locations of tornadoes for residents downstream of the storm. Also, the debris signature locations were used in post-event storm surveys to help locate areas of damage in regions where damage went unreported, or to help separate tornado tracks that were in close proximity to each other. Furthermore, the relative locations of the debris and damage paths for long track EF-4 and EF-5 tornadoes will be ascertained by careful comparison of the ARMOR analysis with NASA MODIS (Moderate Resolution Imaging Spectroradiometer) and ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) satellite imagery of the tornado damage scenes and the National Weather Service tornado damage surveys.

  5. Review of worldwide occurrence of tornadoes

    CSIR Research Space (South Africa)

    Goliger, Adam M

    1998-01-01

    Full Text Available of about 3]10~5/yr/km2. Tornado events were also reported in Holland, Spain, Switzerland and Malta. 6. Africa Tornado events have been recorded in several Southern African countries (Bot- swana, Swaziland and Namibia) and possibly over Liberia, Ivory Coast...

  6. Solar Tornadoes Triggered by Interaction between Filaments and EUV Jets

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Huadong; Zhang, Jun; Ma, Suli [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Yan, Xiaoli [Yunnan Observatories, Chinese Academy of Sciences, Kunming 650011 (China); Xue, Jianchao, E-mail: hdchen@nao.cas.cn, E-mail: zjun@nao.cas.cn [Key Laboratory for Dark Matter and Space Science, Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China)

    2017-05-20

    We investigate the formations and evolutions of two successive solar tornadoes in/near AR 12297 during 2015 March 19–20. Recurrent EUV jets close to two filaments were detected along a large-scale coronal loop prior to the appearances of the tornadoes. Under the disturbances from the activities, the filaments continually ascended and finally interacted with the loops tracked by the jets. Subsequently, the structures of the filaments and the loop were merged together, probably via magnetic reconnections, and formed tornado-like structures with a long spiral arm. Our observations suggest that solar tornadoes can be triggered by the interaction between filaments and nearby coronal jets, which has rarely been reported before. At the earlier development phase of the first tornado, about 30 small-scale sub-jets appeared in the tornado’s arm, accompanied by local EUV brightenings. They have an ejection direction approximately vertical to the axis of the arm and a typical maximum speed of ∼280 km s{sup −1}. During the ruinations of the two tornadoes, fast plasma outflows from the strong EUV brightenings inside tornadoes are observed, in company with the untangling or unwinding of the highly twisted tornado structures. These observational features indicate that self reconnections probably occurred between the tangled magnetic fields of the tornadoes and resulted in the rapid disintegrations and disappearances of the tornadoes. According to the reconnection theory, we also derive the field strength of the tornado core to be ∼8 G.

  7. Solar Tornadoes Triggered by Interaction between Filaments and EUV Jets

    International Nuclear Information System (INIS)

    Chen, Huadong; Zhang, Jun; Ma, Suli; Yan, Xiaoli; Xue, Jianchao

    2017-01-01

    We investigate the formations and evolutions of two successive solar tornadoes in/near AR 12297 during 2015 March 19–20. Recurrent EUV jets close to two filaments were detected along a large-scale coronal loop prior to the appearances of the tornadoes. Under the disturbances from the activities, the filaments continually ascended and finally interacted with the loops tracked by the jets. Subsequently, the structures of the filaments and the loop were merged together, probably via magnetic reconnections, and formed tornado-like structures with a long spiral arm. Our observations suggest that solar tornadoes can be triggered by the interaction between filaments and nearby coronal jets, which has rarely been reported before. At the earlier development phase of the first tornado, about 30 small-scale sub-jets appeared in the tornado’s arm, accompanied by local EUV brightenings. They have an ejection direction approximately vertical to the axis of the arm and a typical maximum speed of ∼280 km s −1 . During the ruinations of the two tornadoes, fast plasma outflows from the strong EUV brightenings inside tornadoes are observed, in company with the untangling or unwinding of the highly twisted tornado structures. These observational features indicate that self reconnections probably occurred between the tangled magnetic fields of the tornadoes and resulted in the rapid disintegrations and disappearances of the tornadoes. According to the reconnection theory, we also derive the field strength of the tornado core to be ∼8 G.

  8. Solar Tornadoes Triggered by Interaction between Filaments and EUV Jets

    Science.gov (United States)

    Chen, Huadong; Zhang, Jun; Ma, Suli; Yan, Xiaoli; Xue, Jianchao

    2017-05-01

    We investigate the formations and evolutions of two successive solar tornadoes in/near AR 12297 during 2015 March 19-20. Recurrent EUV jets close to two filaments were detected along a large-scale coronal loop prior to the appearances of the tornadoes. Under the disturbances from the activities, the filaments continually ascended and finally interacted with the loops tracked by the jets. Subsequently, the structures of the filaments and the loop were merged together, probably via magnetic reconnections, and formed tornado-like structures with a long spiral arm. Our observations suggest that solar tornadoes can be triggered by the interaction between filaments and nearby coronal jets, which has rarely been reported before. At the earlier development phase of the first tornado, about 30 small-scale sub-jets appeared in the tornado’s arm, accompanied by local EUV brightenings. They have an ejection direction approximately vertical to the axis of the arm and a typical maximum speed of ˜280 km s-1. During the ruinations of the two tornadoes, fast plasma outflows from the strong EUV brightenings inside tornadoes are observed, in company with the untangling or unwinding of the highly twisted tornado structures. These observational features indicate that self reconnections probably occurred between the tangled magnetic fields of the tornadoes and resulted in the rapid disintegrations and disappearances of the tornadoes. According to the reconnection theory, we also derive the field strength of the tornado core to be ˜8 G.

  9. Matching of Tore Supra ICRH antennas

    International Nuclear Information System (INIS)

    Ladurelle, L.; Beaumont, B.; Kuus, H.; Lombard, G.

    1994-01-01

    An automatic matching method is described for Tore Supra ICRH antennas based on impedance variations seen at their feed points. Error signals derived from directional voltage and phase measurements in the feeder allow to control the matching capacitors values for optimal power transmission. (author) 5 refs.; 9 figs

  10. TORE SUPRA fast reciprocating radio frequency probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  11. Two Categories of Apparent Tornado-like Prominences

    Science.gov (United States)

    Martin, Sara F.; Venkataramanasastry, Aparna

    2014-06-01

    Two categories of solar prominences have been described in the literature as having a pattern of mass motions and/or a shape similar to terrestrial tornados. We first identify the two categories associated with prominences in the historic literature and then show that counterparts do exist for both in recent literature but one has not been called a tornado prominence. One category described as being similar to tornados is associated with the barbs of quiescent filaments but barbs appear to have rotational motion only under special conditions. H alpha Doppler observations from Helio Research confirm that this category is an illusion in our mind’s eye resulting from counterstreaming in the large barbs of quiescent filaments. The second category is a special case of rotational motion occurring during the early stages of some erupting prominences, in recent years called the roll effect in erupting prominences. In these cases, the eruption begins with the sideways rolling of the top of a prominence. As the eruption proceeds the rolling motion propagates down one leg or both legs of an erupting prominence depending on whether the eruption is asymmetric or symmetric respectively. As an asymmetric eruption proceeds, the longer lasting leg becomes nearly vertical and has true rotational motion. If only this phase of the eruption was observed, as in the historic cases, it was called a tornado prominence and spectra recorded in these cases provide proof of the rotational motion. When one observes an entire eruption which exhibits the rolling motion, as accomplished at Helio Research, the similarity to a tornado is lost because the event as a whole has quite a different nature and the analogy to a terrestrial tornado not longer appears suitable or helpful in understanding the observed and deduced physical processes. Our conclusion is that there are no solar prominences with motions that are usefully described as tornado or tornado-like events aside from the fun of observing

  12. Tore Supra: technical aspects and early results after one year of operation

    International Nuclear Information System (INIS)

    Gravier, R.

    1989-01-01

    After one year operation (1988 to 1989), technical aspects of component systems and equipment of Tore Supra are summarized. Particular attention is given to the operation with: supraconducting toroidal field coil system, cryogenic system, poloidal field system, in vessel equipment, first wall conditioning, pump limiter. The ergodic divertor experiments and the current drive experiment are reported. The plasma heating methods adopted in Tore Supra are presented

  13. Ohmic discharges in Tore Supra - Marfes and detached plasmas

    International Nuclear Information System (INIS)

    Vallet, J.C.

    1990-01-01

    The Tore Supra plasma characteristics are given. The observed discharges are either leaning on the graphite inner first wall or limited by movable pump limiters located outboard and at the bottom of the vacuum chamber. The particular plasma conditions which lead to marfes and detached plasmas in ohmically heated He and D2 discharges limited by the inner wall are investigated. The results show that the ratio of radiated power to ohmic power increase linearly with M.g. As M.g rises, attached plasma, marfe and detached plasma are sequentially observed. Detached plasma with an effective radius as small as. 7 times the limiter radius was observed on Tore Supra

  14. First lower hybrid current drive experiments at 3.7 GHz in Tore Supra

    International Nuclear Information System (INIS)

    Tonon, G.; Goniche, M.; Moreau, D.

    1989-01-01

    The results of electromagnetic waves injection in the Tore Supra plasma, at a frequency of 3.7 GHz, are reported. The process is applied for current generation and plasma heating, through Landau damping on the electron population. The experimental set-up is described. The lower hybrid current drive experiments in Tore Supra are carried out under the following conditions: major and minor radii of the plasma are respectively 2.37 m and 0.77 m and the toroidal magnetic field is 1.8 Teslas. A multijunction-grill composed of 128 waveguides is applied. Up to 1.25 MW of rf power is injected in Tore Supra, after less than 30 plasma shots. The results lead to the conclusion that the coupling, not yet optimized, is good enough for safe klystron operation with no circulator. The measured value RIp P RF -1 (δV L /V L ) obtained on Tore Supra (Bt = 1.8 T) is closed to one observed on PETULA-B (Bt = 2.75 T) at the same frequency and density

  15. Modern tornado design of nuclear and other potentially hazardous facilities

    International Nuclear Information System (INIS)

    Stevenson, J.D.; Zhao, Y.

    1996-01-01

    Tornado wind loads and other tornado phenomena, including tornado missiles and differential pressure effects, have not usually been considered in the design of conventional industrial, commercial, or residential facilities in the United States; however, tornado resistance has often become a design requirement for certain hazardous facilities, such as large nuclear power plants and nuclear materials and waste storage facilities, as well as large liquefied natural gas storage facilities. This article provides a review of current procedures for the design of hazardous industrial facilities to resist tornado effects. 23 refs., 19 figs., 13 tabs

  16. Cold-Season Tornadoes: Climatological, Meteorological, and Social Perspectives

    Science.gov (United States)

    Childs, Samuel J.

    Tornadoes that occur during the cold season, defined here as November-February (NDJF), pose many unique societal risks. For example, people can be caught off-guard because in general one does not expect severe weather and tornadoes during winter months. The public can also be unsuspecting of significant weather due to the bustle of major holidays like Thanksgiving, Christmas, and New Year's, when most people are concerned with family activities and not thinking about the weather. Cold-season tornadoes also have a propensity to be nocturnal and occur most frequently in the South and Southeastern U.S., where variable terrain, inadequate resources, and a relatively high mobile home density add additional social vulnerabilities. Over the period 1953-2015 within a study domain of (25-42.5°N, 75-100°W), some 937 people lost their lives as a result of NDJF tornadoes. Despite this enhanced societal risk of cold-season tornadoes in the South, very little attention has been given to their meteorological characteristics and climate patterns, and public awareness of their potential impacts is lacking. This thesis aims to greatly advance the current state of knowledge of NDJF tornadoes by providing an in-depth investigation from three different science perspectives. First, a climatology of all (E)F1-(E)F5 NDJF tornadoes is developed, spanning the period 1953-2015 within a domain of (25-42.5°N, 75-100°W), in order to assess frequency and spatial changes over time. A large increasing trend in cold-season tornado occurrence is found across much of the Southeastern U.S., with the greatest uptick in Tennessee, while a decreasing trend is found across eastern Oklahoma. Spectral analysis reveals a cyclic pattern of enhanced NDJF counts every 3-7 years, coincident with the known period for ENSO. Indeed, La Nina episodes are found to be correlated with NDJF tornado counts, although a stronger teleconnection correlation exists with the Arctic Oscillation (AO), which explains 25% of

  17. Excitation of beta Alfven eigenmodes in Tore-Supra

    International Nuclear Information System (INIS)

    Nguyen, C; Garbet, X; Sabot, R; Goniche, M; Maget, P; Basiuk, V; Decker, J; Elbeze, D; Huysmans, G T A; Macor, A; Segui, J-L; Schneider, M; Eriksson, L-G

    2009-01-01

    Modes oscillating at the acoustic frequency and identified as beta Alfven eigenmodes (BAEs) have been observed in Tore-Supra under ion cyclotron resonant heating. In this paper, the linear excitation threshold of these modes, thought to be driven by suprathermal ions, is calculated and compared with Tore-Supra observations. Similar studies of the linear excitation threshold of energetic particles driven modes were carried out previously for toroidal Alfven eigenmodes or fishbones. In the case of BAEs, the main point is to understand whether the energetic particle drive is able to exceed ion Landau damping, which is expected to be important in the acoustic frequency range. For this, the BAE dispersion relation is computed and simplified in order to derive a tractable excitation criterion suitable for comparison with experiments. The observation of BAEs in Tore-Supra is found to be in agreement with the calculated criterion and confirms the possibility to trigger these modes in the presence of ion Landau damping. Moreover, the conducted analysis clearly puts forward the role of the global tunable parameters which play a role in the BAE excitation (the magnetic field, the density etc), as well as the role of some plasma profiles. In particular, the outcome of a modification of the shear or of the heating localization is found to be non-negligible and it is discussed in the paper.

  18. Family emergency preparedness plans in severe tornadoes.

    Science.gov (United States)

    Cong, Zhen; Liang, Daan; Luo, Jianjun

    2014-01-01

    Tornadoes, with warnings usually issued just minutes before their touchdowns, pose great threats to properties and people's physical and mental health. Few studies have empirically investigated the association of family emergency preparedness planning and observed protective behaviors in the context of tornadoes. The purpose of this study was to examine predictors for the action of taking shelter at the time of tornadoes. Specifically, this study investigated whether having a family emergency preparedness plan was associated with higher likelihood of taking shelter upon receiving tornado warnings. This study also examined the effects of socioeconomic status and functional limitations on taking such actions. A telephone survey based on random sampling was conducted in 2012 with residents in Tuscaloosa AL and Joplin MO. Each city experienced considerable damages, injuries, and casualties after severe tornadoes (EF-4 and EF-5) in 2011. The working sample included 892 respondents. Analysis was conducted in early 2013. Logistic regression identified emergency preparedness planning as the only shared factor that increased the likelihood of taking shelter in both cities and the only significant factor in Joplin. In Tuscaloosa, being female and white also increased the likelihood of taking shelter. Disability was not found to have an effect. This study provided empirical evidence on the importance of having a family emergency preparedness plan in mitigating the risk of tornadoes. The findings could be applied to other rapid-onset disasters. © 2013 American Journal of Preventive Medicine Published by American Journal of Preventive Medicine All rights reserved.

  19. Re-interpreting Prominences Classified as Tornadoes

    Science.gov (United States)

    Martin, Sara F.; Venkataramanasastry, Aparna

    2015-04-01

    Some papers in the recent literature identify tornado prominences with barbs of quiescent prominences while papers in the much older historic literature include a second category of tornado prominence that does not correspond to a barb of a quiescent prominence. The latter are described as prominence mass rotating around a nearly vertical axis prior to its eruption and the rotation was verified by spectral measurements. From H alpha Doppler-shifted mass motions recorded at Helio Research or the Dutch Open Telescope, we illustrate how the apparent tornado-like motions, identified with barbs, are illusions in our mind’s eye resulting from poorly resolved counterstreaming threads of mass in the barbs of quiescent prominences. In contrast, we confirm the second category of rotational motion in prominences shortly before and during eruption. In addition, we identify this second category as part of the late phase of a phenomenon called the roll effect in erupting prominences. In these cases, the eruption begins with the sideways rolling of the top of a prominence. As the eruption proceeds the rolling motion propagates down one leg or both legs of the prominence depending on whether the eruption is asymmetric or symmetric respectively. As an asymmetric eruption continues, the longer lasting leg becomes nearly vertical and its rotational motion also continues. If only this phase of the eruption was observed, as in some historic cases, it was called a tornado prominence. However, when we now observe entire eruptions in time-lapse sequences, the similarity to terrestrial tornadoes is lost. We conclude that neither prominence barbs, that give the illusion of rotation, nor the cases of true rotational motion, in the legs of erupting prominences, are usefully described as tornado prominences when the complete prominence structure or complete erupting event is observed.

  20. 300 W - 1.75 K TORE SUPRA refrigerator cold centrifugal compressors report

    International Nuclear Information System (INIS)

    Gistau, G.M.; Pecoud, Y.; Ravex, A.E.

    1988-01-01

    The centrifugal helium compressors for the TORE SUPRA tokamak refrigerator were designed and manufactured by L'Air Liquide and tested at nominal conditions on a custom test rig. The refrigerator is now installed and all acceptance tests have been completed. Other tests were carried out off design conditions with the machines installed in the TORE SUPRA refrigerator. The results of these tests, including compression ratio, efficiency, and heat losses, are discussed

  1. US tornadoes. Part 1: 70-year statistics

    Science.gov (United States)

    Fujita, T. T.

    1987-01-01

    If tornadoes were counted as the Gross National Product, no other country on the surface of the earth could come even close to the United States. During the recent 70 year period, the United States produced 31,054 tornadoes which left behind a cumulative path of 132,005 miles (212,396 km) which would circle the world 5.3 times along the equator. In completing the book, staff members of the Satellite and Mesometeorlogy Research Project (1961 to the present) played an important role in collecting, evaluating, and archiving the historical tornado data.

  2. The TORE SUPRA fast reciprocating RF probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.

    1994-01-01

    A fast reciprocating ICRF (Ion Cyclotron Range of Frequencies) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at ORNL. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal RF magnetic fields and the other senses poloidal RF magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm and a fast stroke (1.5 m/sec) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 cm to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data shows parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  3. Predictors of compliance with tornado warnings issued in Joplin, Missouri, in 2011.

    Science.gov (United States)

    Paul, Bimal Kanti; Stimers, Mitchel; Caldas, Marcellus

    2015-01-01

    Joplin, a city in the southwest corner of Missouri, United States, suffered an EF-5 tornado in the late afternoon of 22 May 2011. This event, which claimed the lives of 162 people, represents the deadliest single tornado to strike the US since modern record-keeping began in 1950. This study examines the factors associated with responses to tornado warnings. Based on a post-tornado survey of survivors in Joplin, it reveals that tornado warnings were adequate and timely. Multivariate logistic regression identified four statistically significant determinants of compliance with tornado warnings: number of warning sources, whether respondents were at home when the tornado struck, past tornado experience, and gender. The findings suggest several recommendations, the implementation of which will further improve responses to tornado warnings. © 2014 The Author(s). Disasters © Overseas Development Institute, 2014.

  4. The data acquisition and interlock system for Tore Supra infrared imaging

    International Nuclear Information System (INIS)

    Moulin, D.; Balorin, C.; Buravand, Y.; Caulier, G.; Ducobu, L.; Guilhem, D.; Jouve, M.; Roche, H.

    2003-01-01

    The data acquisition for the infrared measurement system on Tore-Supra is a key element in ensuring the supervision of the new actively-cooled plasma facing components of the CIEL project. It will allow us to follow the thermal evolution of components of Tore-Supra, in particular the toroidal pumped limiter (LPT) (360 deg.-15 m long) and the five additional heating launchers. When fully installed, the infrared measurement system will be composed of 12 digital 16-bit infrared cameras. They cover a 100-1200 deg.C temperature range and each picture has a definition of 320x240 pixels with a 20 ms time resolution. The objectives of the data acquisition system is real-time recording and analysis of each view element for further post-pulse analysis in order to understand the physics phenomenon and ensure the supervision of the plasma facing components and also to be part of the global feedback control system of Tore Supra

  5. Towards operations on Tore Supra of an ITER relevant inspection robot and associated processes

    International Nuclear Information System (INIS)

    Laurent Gargiulo, L.; Cordier, J.-J.; Samaille, F.; Grisolia, Ch.; Perrot, Y.; Olivier, D.; Friconneau, J.-P.; Palmer, J.

    2006-01-01

    The aim of the project is to demonstrate on Tore Supra the reliability of a multi-purpose in-vessel Remote Handling inspection system using a long reach, limited payload carrier. This project called AIA (Articulated Inspection Arm) is currently being developed at CEA under a European EFDA work program. The paper describes the detailed design, the manufacturing processes and the results of the first module test campaign in the CEA Tore Supra ME60 facility, at representative vacuum, temperature and nominal loading conditions. The second part of this work that is reported in the paper, concerns the description of the whole integration of the device on the Tore Supra tokamak that is foreseen to be operated on Tore Supra early 2007. The deployer system and the 10 m long storage vacuum vessel are presented. The robot prototype is fully representative of the deployment carrier system that could be required on ITER. The demonstration on Tore Supra will help in the understanding of operation issues that could occur in the tokamak vacuum vessel equipped of actively cooled components. The viewing process that is currently under development is presented in the paper. It will allow close inspection of the Tore Supra Plasma Facing Components that are representative of the ITER divertor targets in terms of confined environment and identification of possible tiles failure of CFC carbon tiles. Such viewing process could be used on ITER during the early stage of operation under a limited radiation level. The AIA technology is also showing promising potential for generic application in alternative systems for ITER. The feasibility study for viewing inspection of the beam line components in the neutral beam test facility is presented. One of the other potential inspection processes that is foreseen to be tested using the AIA carrier in Tore Supra is the laser ablation system of the CFC armour. It could be fully relevant for the ITER wall detritiation issues. Such process can be

  6. Experience from Tore Supra acquisition system and evolutions

    International Nuclear Information System (INIS)

    Guillerminet, B.; Buravand, Y.; Chatelier, E.; Leroux, F.

    2004-01-01

    The Tore Supra tokamak has been upgraded to explore long duration plasma discharges up to 1000s. Since summer 2001, the acquisition system operates in continuous mode apart of the data processing which is still done after the pulse. In the first part, we explore a few solutions to process continuously the data during the pulse, based on parallel processing on a Linux farm and then on a CONDOR system. The second part is devoted to the Web service exposing the Tore Supra operation. In the last part, the VME acquisition system has been redesigned to keep up with the high data rates required by a few diagnostics. The workflow is now distributed among a few computers. At the end, we give the current status of the realisation and the future planning

  7. Heat Loads On Tore Supra ICRF Launchers Plasma Facing Components

    International Nuclear Information System (INIS)

    Bremond, S.; Colas, L.; Chantant, M.; Beaumont, B.; Ekedahl, A.; Goniche, M.; Moreau, P.; Mitteau, R.

    2005-01-01

    Understanding the heat loads on Ion Cyclotron Range of Frequency launchers plasma facing components is a crucial task both for operating present tokamaks and for designing ITER ICRF launchers as these loads may limit the RF power coupling capability. Tore Supra facility is particularly well suited to take this issue. Parametric studies have been performed which enables to get an overall detailed picture of the different heat loads on several areas, pointing to different mechanisms at the origin of the heat power fluxes. Lessons are drawned both with regards to Tore Supra possible operational limits and to ITER ICRF launcher design

  8. Physical Patterns Associated with 27 April 2011 Tornado Outbreak

    Science.gov (United States)

    Ramos, Fernanda; Salem, Thomas

    2012-02-01

    The National Weather Service office in Memphis, Tennessee has aimed their efforts to improve severe tornado forecasting. Everything is not known about tornadogenesis, but one thing is: tornadoes tend to form within supercell thunderstorms. Hence, 27 April 2011 and 25 May 2011 were days when a Tornado Outbreak was expected to arise. Although 22 tornadoes struck the region on 27 April 2011, only 1 impacted the area on 25 May 2011. In order to understand both events, comparisons of their physical features were made. These parameters were studied using the Weather Event Simulator system and the NOAA/NWS Storm Prediction database. This research concentrated on the Surface Frontal Analysis, NAM40 700mb Dew-Points, NAM80 250mb Wind Speed and NAM20 500mb Vorticity images as well as 0-6 km Shear, MUCAPE and VGP mesoscale patterns. As result of this research a Dry-Line ahead of a Cold Front, Dew-points 5C and higher, and high Vorticity values^ were synoptic patterns that influenced to the formation of supercell tornadoes. Finally, MUCAPE and VGP favored the possibility of tornadoes occurrence on 25 May 2011, but shear was the factor that made 27 April 2011 a day for a Tornado Outbreak weather event.

  9. Statistical Models for Tornado Climatology: Long and Short-Term Views.

    Science.gov (United States)

    Elsner, James B; Jagger, Thomas H; Fricker, Tyler

    2016-01-01

    This paper estimates regional tornado risk from records of past events using statistical models. First, a spatial model is fit to the tornado counts aggregated in counties with terms that control for changes in observational practices over time. Results provide a long-term view of risk that delineates the main tornado corridors in the United States where the expected annual rate exceeds two tornadoes per 10,000 square km. A few counties in the Texas Panhandle and central Kansas have annual rates that exceed four tornadoes per 10,000 square km. Refitting the model after removing the least damaging tornadoes from the data (EF0) produces a similar map but with the greatest tornado risk shifted south and eastward. Second, a space-time model is fit to the counts aggregated in raster cells with terms that control for changes in climate factors. Results provide a short-term view of risk. The short-term view identifies a shift of tornado activity away from the Ohio Valley under El Niño conditions and away from the Southeast under positive North Atlantic oscillation conditions. The combined predictor effects on the local rates is quantified by fitting the model after leaving out the year to be predicted from the data. The models provide state-of-the-art views of tornado risk that can be used by government agencies, the insurance industry, and the general public.

  10. l tornado che colpì la laguna di Venezia I ' l l Settembre 1970 Qualche considerazione intorno alla teoria elettrica dei tornado

    Directory of Open Access Journals (Sweden)

    R. JANESELLI

    1972-06-01

    Full Text Available After a short description of the disastrous effects of the
    tornado which struck the Venice lagoon on September 11, 1970, the principal
    theories which in the centuries tried to account for the origin of such
    terrible vortexes, are reviewed. In particular, some remarks are given about
    the electrical theory of the tornadoes. It seems to the author that some features
    would be explained in a simple way by considering the tornado as a
    convectivo cell with electric currents of high intensity. Finally, after recalling
    the meteorological conditions preceding the tornado of September 11,
    its chief features are described.

  11. Dynamical analysis and visualization of tornadoes time series.

    Directory of Open Access Journals (Sweden)

    António M Lopes

    Full Text Available In this paper we analyze the behavior of tornado time-series in the U.S. from the perspective of dynamical systems. A tornado is a violently rotating column of air extending from a cumulonimbus cloud down to the ground. Such phenomena reveal features that are well described by power law functions and unveil characteristics found in systems with long range memory effects. Tornado time series are viewed as the output of a complex system and are interpreted as a manifestation of its dynamics. Tornadoes are modeled as sequences of Dirac impulses with amplitude proportional to the events size. First, a collection of time series involving 64 years is analyzed in the frequency domain by means of the Fourier transform. The amplitude spectra are approximated by power law functions and their parameters are read as an underlying signature of the system dynamics. Second, it is adopted the concept of circular time and the collective behavior of tornadoes analyzed. Clustering techniques are then adopted to identify and visualize the emerging patterns.

  12. Acoustic detection, tracking, and characterization of three tornadoes.

    Science.gov (United States)

    Frazier, William Garth; Talmadge, Carrick; Park, Joseph; Waxler, Roger; Assink, Jelle

    2014-04-01

    Acoustic data recorded at 1000 samples per second by two sensor arrays located at ranges of 1-113 km from three tornadoes that occurred on 24 May 2011 in Oklahoma are analyzed. Accurate bearings to the tornadoes have been obtained using beamforming methods applied to the data at infrasonic frequencies. Beamforming was not viable at audio frequencies, but the data demonstrate the ability to detect significant changes in the shape of the estimated power spectral density in the band encompassing 10 Hz to approximately 100 Hz at distances of practical value from the sensors. This suggests that arrays of more closely spaced sensors might provide better bearing accuracy at practically useful distances from a tornado. Additionally, a mathematical model, based on established relationships of aeroacoustic turbulence, is demonstrated to provide good agreement to the estimated power spectra produced by the tornadoes at different times and distances from the sensors. The results of this analysis indicate that, qualitatively, an inverse relationship appears to exist between the frequency of an observed peak of the power spectral density and the reported tornado intensity.

  13. Dynamical analysis and visualization of tornadoes time series.

    Science.gov (United States)

    Lopes, António M; Tenreiro Machado, J A

    2015-01-01

    In this paper we analyze the behavior of tornado time-series in the U.S. from the perspective of dynamical systems. A tornado is a violently rotating column of air extending from a cumulonimbus cloud down to the ground. Such phenomena reveal features that are well described by power law functions and unveil characteristics found in systems with long range memory effects. Tornado time series are viewed as the output of a complex system and are interpreted as a manifestation of its dynamics. Tornadoes are modeled as sequences of Dirac impulses with amplitude proportional to the events size. First, a collection of time series involving 64 years is analyzed in the frequency domain by means of the Fourier transform. The amplitude spectra are approximated by power law functions and their parameters are read as an underlying signature of the system dynamics. Second, it is adopted the concept of circular time and the collective behavior of tornadoes analyzed. Clustering techniques are then adopted to identify and visualize the emerging patterns.

  14. TORE SUPRA fast reciprocating radio frequency probe (abstract)

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  15. Tornado missile impact study

    International Nuclear Information System (INIS)

    McDonald, J.R.

    1991-01-01

    UCRL-15910 specifies wind and tornado missiles for moderate- and high-hazard DOE facilities. Wall-barrier specimens have been tested at the Tornado Missile Impact Facility at Texas Tech University. The facility has an air-activated tornado missile cannon capable of firing 2x4 timber planks weighing 12 lb at speeds up to 150 mph and 3-in-diameter steel pipes weighing 75 lb at speeds to 7 5 mph. Wall barriers tested to date include reinforced concrete walls from 4-in. to 10-in. thick; 8-in. and 12-in. walls of reinforced concrete masonry units (CMU); two other masonry wall configurations consisting of an 8-in. CMU with a 4-in. clay-brick veneer and a 10-in. composite wall with two wythes of 4-in. clay brick. The impact test series is designed to determine the impact speed that will produce backface spall of each wall barrier. A set of 15 wall sections has been constructed and tested at this time. Preliminary finding suggest that all cells of CMU walls must be grouted to prevent missile penetration. Walls recommended in the workshop on UCRL-15910 provide acceptable protection if cracking can be accepted

  16. Tornado missiles protections taken at the Ikata NPP of SEPCO

    International Nuclear Information System (INIS)

    Ikeda, Kazutoyo; Takagi, Toshimitsu; Inoue, Haruhisa; Yoshida, Hisao; Moriuchi, Takehiro

    2014-01-01

    On July 8, 2013, the new regulatory requirements for commercial power reactors got in force. Based on a concept of 'Defense-in-depth', essential importance was placed on the third and fourth layers of defense and prevention of simultaneous loss of all safety functions due to common causes. In this regards, the previous assumptions on the impact of earthquakes, tsunamis and other external events such as volcanic eruptions, tornadoes and forest fires were re-evaluated, and countermeasures for nuclear safety against these external events were decided to be enhanced. For tornado, Nuclear Regulation Authority promulgated the 'Assessment Guide for Tornado Effect on Nuclear Power Plants' to evaluate the effect of tornadoes. This paper will introduce the outline of evaluation cases of tornado effect, and tornado missiles protections taken at the Ikata Unit 3 Nuclear Power Plant (for actual case studies). (author)

  17. Implementation of FCI heating system to the control system of Tore-Supra

    International Nuclear Information System (INIS)

    Wisniewski, S.

    2001-11-01

    This report presents the implementation of the ion cyclotron resonance heating system (FCI) to the instrumentation and control system of the Tore-Supra tokamak. The new plasma heating system involves 3 antennas delivering 12 MW that are required to maintain fusion reactions. This paper is divided into 8 chapters: 1) thermonuclear fusion and Tore-Supra tokamak; 2) hardware system around Tore-Supra, in this chapter the control system and the data acquisition and processing systems are presented; 3) functional analysis, this analysis defines the different needs concerning timing and pilot-controlling, a preliminary proposition of hardware equipment is made; 4) operating modes of FCI; 5) communication within the control system network; 6) communication with the supervisory system of the power stations; 7) management of data exchange with SMX generators; and 8) control of the rate of stationary waves during the injection of power into the plasma

  18. Examining social, physical, and environmental dimensions of tornado vulnerability in Texas.

    Science.gov (United States)

    Siebeneck, Laura

    2016-01-01

    To develop a vulnerability model that captures the social, physical, and environmental dimensions of tornado vulnerability of Texas counties. Guided by previous research and methodologies proposed in the hazards and emergency management literature, a principle components analysis is used to create a tornado vulnerability index. Data were gathered from open source information available through the US Census Bureau, American Community Surveys, and the Texas Natural Resources Information System. Texas counties. The results of the model yielded three indices that highlight geographic variability of social vulnerability, built environment vulnerability, and tornado hazard throughout Texas. Further analyses suggest that counties with the highest tornado vulnerability include those with high population densities and high tornado risk. This article demonstrates one method for assessing statewide tornado vulnerability and presents how the results of this type of analysis can be applied by emergency managers towards the reduction of tornado vulnerability in their communities.

  19. ORNL compact loop antenna design for TFTR and Tore Supra

    International Nuclear Information System (INIS)

    Taylor, D.J.; Baity, F.W.; Bryan, W.E.; Hoffman, D.J.; McIlwain, R.L.; Ray, J.M.

    1987-01-01

    The goal supplemental ion cyclotron resonance heating (ICRH) of fusion plasma is to deliver power at high efficiencies deep within the plasma. The technology for fast-wave ICRH has reached the point of requiring ''proof-of-performance'' demonstration of specific antenna configurations of specific antenna configurations and their mechanical adequacy for operating in a fusion environment. Oak Ridge National Laboratory (ORNL) has developed the compact loop antenna concept based on a resonant double loop (RDL) configuration for use in both Tokamak Fusion Test Reactor (TFTR) and the Tore Supra ICRH programs. A description and a comparison of the technologies developed in the two designs are presented. The electrical circuit and the mechanical philosophy employed are the same for both antennas, but different operating environments result in substantial differences in the design of specific components. The ORNL TFTR antenna is designed to deliver 4 MW over a 2-s pulse, and the ORNL Tore Supra antenna is designed for 4 MW and essentially steady-state conditions. The TFTR design embodies the first operations compact RDL antenna, and the Tore Supra antenna extends the technology to an operational duty cycle consistent with reactor-relevant applications. 7 refs., 5 figs

  20. Theoretical tornado vortex model for nuclear plant design

    International Nuclear Information System (INIS)

    Sun, C.N.; Barnett, R.O.; Burdette, E.G.

    1977-01-01

    A simplified tornado vortex model is defined using fluid dynamics theory. Beginning with the Navier-Stokes equations of motion for an incompressible fluid and simpifying in a way consistent with a tornado wind field, develops the well-known cyclostrophic wind equation referred to by Hoecker and another equation which defines the tangential velocity profile. Together, they define a simplified tornado vertex model of which the Rankine and Hoecker vortices are special cases. Practical implications of the results obtained are discussed. (Auth.)

  1. Implementation of FCI heating system to the control system of Tore-Supra; Integration du systeme de chauffage FCI au sein du reseau de controle commande du Tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, S

    2001-11-01

    This report presents the implementation of the ion cyclotron resonance heating system (FCI) to the instrumentation and control system of the Tore-Supra tokamak. The new plasma heating system involves 3 antennas delivering 12 MW that are required to maintain fusion reactions. This paper is divided into 8 chapters: 1) thermonuclear fusion and Tore-Supra tokamak; 2) hardware system around Tore-Supra, in this chapter the control system and the data acquisition and processing systems are presented; 3) functional analysis, this analysis defines the different needs concerning timing and pilot-controlling, a preliminary proposition of hardware equipment is made; 4) operating modes of FCI; 5) communication within the control system network; 6) communication with the supervisory system of the power stations; 7) management of data exchange with SMX generators; and 8) control of the rate of stationary waves during the injection of power into the plasma.

  2. Spatial Distributions of Tropical Cyclone Tornadoes by Intensity and Size Characteristics

    Directory of Open Access Journals (Sweden)

    Todd W. Moore

    2017-08-01

    Full Text Available Tropical cyclones that make landfall often spawn tornadoes. Previous studies have shown that these tornadoes are not uniformly distributed in the United States or in the tropical cyclone environment. They show that tornadoes tend to occur relatively close to the coastline and that they tend to cluster to the east-of-center in the tropical cyclone environment, particularly in the northeast and east-of-center quadrants. This study contributes to these studies by analyzing the spatial distributions of tropical cyclone tornadoes by intensity, path length, path width, and the damage potential index. The analyses confirm that most tornadoes occur relatively close to the coastline, but show that stronger tornadoes with larger paths are disproportionately common farther inland. They also confirm that the highest amount of activity is located within the northeast and east-of-center quadrants and show that the most potentially damaging tornadoes cluster in a sub region near the intersection of these two quadrants.

  3. Tornadoes: Nature's Most Violent Storms. A Preparedness Guide Including Safety Information for Schools.

    Science.gov (United States)

    American National Red Cross, Washington, DC.

    This preparedness guide explains and describes tornadoes, and includes safety information for schools. A tornado is defined as a violently rotating column of air extending from a thunderstorm to the ground. The guide explains the cause of tornadoes, provides diagrams of how they form, describes variations of tornadoes, and classifies tornadoes by…

  4. 3400 m/s deuterium pellet injector for Tore Supra

    International Nuclear Information System (INIS)

    Perin, J.P.; Geraud, A.

    1995-01-01

    This paper reports on the Tore Supra high velocity pellet injector which was built in Grenoble and after qualification tests installed on Tore Supra Tokomak where it is used for plasma and ablation studies. By using a two stage light gas gun (TSG) and two cells (φ = 3 mm or 4 mm), unsupported pellets pellets (1 to 3.5 10 21 atoms) made directly in the gun by > [1] have been launched into Tore Supra plasma at speeds between 2400m/s and 3400m/s with a reliability of 80%. These higher pellets velocities (> 2500 m/s) [2] are obtained by the optimization of a TSG and the search for the cryogenic conditions of freezing deuterium with good mechanical properties. In particular, the impurities concentration in deuterium during the condensation process has been studied. Several tens pellets have been injected into ohmically and ICR heated plasma and during LH current drive experiments with a good reliability in the range of 3000m/s. These experiments allowed us to extend significantly the ablation data base. Central penetrations can be reached even for high temperatures plasma (3-5 keV) and very peaked density profiles have been obtained in ohmically and ICR heated plasmas A transient improved confinement regime is then observed, which presents some features similar to the PEP regime obtained on JET. (orig.)

  5. Design of convolutional tornado code

    Science.gov (United States)

    Zhou, Hui; Yang, Yao; Gao, Hongmin; Tan, Lu

    2017-09-01

    As a linear block code, the traditional tornado (tTN) code is inefficient in burst-erasure environment and its multi-level structure may lead to high encoding/decoding complexity. This paper presents a convolutional tornado (cTN) code which is able to improve the burst-erasure protection capability by applying the convolution property to the tTN code, and reduce computational complexity by abrogating the multi-level structure. The simulation results show that cTN code can provide a better packet loss protection performance with lower computation complexity than tTN code.

  6. Tornadoes and related damage costs: statistical modeling with a semi-Markov approach

    OpenAIRE

    Corini, Chiara; D'Amico, Guglielmo; Petroni, Filippo; Prattico, Flavio; Manca, Raimondo

    2015-01-01

    We propose a statistical approach to tornadoes modeling for predicting and simulating occurrences of tornadoes and accumulated cost distributions over a time interval. This is achieved by modeling the tornadoes intensity, measured with the Fujita scale, as a stochastic process. Since the Fujita scale divides tornadoes intensity into six states, it is possible to model the tornadoes intensity by using Markov and semi-Markov models. We demonstrate that the semi-Markov approach is able to reprod...

  7. Snake studies on TORE-SUPRA

    International Nuclear Information System (INIS)

    Cristofani, P.; Desgranges, C.; Garbet, X.; Geraud, A.; Gil, C.; Hoang, G.T.; Joffrin, E.; Pecquet, A.L.

    1994-01-01

    Snakes have been achieved after pellet injection in TORE-SUPRA during ohmic as well as ICRH discharges as it has already been observed in other machines. They are usually localized on a region around the q=1 surface, and correspond mainly to a perturbation of the density profile. The formation of the snake depends on the penetration depth L p of the pellet: the maximum of ablation must be well inside the q=1 surface, this condition is necessary but not sufficient to produce snakes. For example on TORE-SUPRA high speed H 2 pellets (1500 m/s and approximately 10 21 atoms) were injected into D 2 plasmas with following parameters: I p =1.4 MA, B Φ =3 T, T e =1.7 KeV, e >=2-3 10 19 m -3 , a=0.78 m, R=2.4 m, and q a =3.3. In such experimental conditions, the matter is deposited in the centre and snakes are produced in 50% of the cases, but they are created on a second much more internal q=1 surface leading probably to a non monotonic current profile. The first two paragraphs describe the properties of the snake and the induced current modification. The latter paragraph discusses the important role of the bootstrap current in the snake formation. (author) 5 refs., 7 figs

  8. Validation of the LH antenna code ALOHA against Tore Supra experiments

    International Nuclear Information System (INIS)

    Hillairet, J.; Ekedahl, A.; Kocan, M.; Gunn, J. P.; Goniche, M.

    2009-01-01

    Comparisons between ALOHA code predictions and experimental measurements of reflection coefficients for the two different Lower Hybrid Current Drive (LHCD) antennas (named C2 and C3) in Tore Supra are presented. A large variation of density in front of the antennas was obtained by varying the distance between the plasma and the antennas. Low power ( 2 ) was used in order to avoid non-linear effects on the wave coupling. Results obtained with ALOHA are in good agreement with the experimental measurements for both Tore Supra antennas and show that ALOHA is an efficient LH predictive tool.

  9. Touchable Tornadoes

    Science.gov (United States)

    Gilhousen, David

    2004-01-01

    In this article, the author discusses a tornado-producing machine that he used in teacher-led, student assisted demonstrations in order to reinforce concepts learned during a unit on weather. The machine, or simulator, was powered by a hair dryer, fan, and cool-mist humidifier. The machine consists of a demonstration table containing a plenum box,…

  10. A forensic re-analysis of one of the deadliest European tornadoes

    Science.gov (United States)

    Holzer, Alois M.; Schreiner, Thomas M. E.; Púčik, Tomáš

    2018-06-01

    Extremely rare events with high potential impact, such as violent tornadoes, are of strong interest for climatology and risk assessment. In order to obtain more knowledge about the most extreme events, it is vital to study historical cases. The purpose of this paper is twofold: (1) to demonstrate how a windstorm catastrophe that happened 100 years ago, such as the Wiener Neustadt, Lower Austria, tornado on 10 July 1916, can be successfully re-analyzed using a forensic approach, and (2) to propose a repeatable working method for assessing damage and reconstructing the path and magnitude of local windstorm and tornado cases with sufficient historical sources. Based on the results of the forensic re-analyses, a chronology of the tornado impact is presented, followed by a description of the key tornado characteristics: a maximum intensity rating of F4, a damage path length of 20 km and a maximum visible tornado diameter of 1 km. Compared to a historical scientific study published soon after the event, additional new findings are presented, namely the existence of two predecessor tornadoes and a higher number of fatalities: at least 34 instead of 32. While the storm-scale meteorology could not be reconstructed, rich damage data sources for the urban area of Wiener Neustadt facilitated a detailed analysis of damage tracks and wind intensities within the tornado. The authors postulate the requirement for an International Fujita Scale to rate tornadoes globally in a consistent way, based on comparable damage indicators.

  11. The plasma facing components of the Tore Supra ICRF antenna

    International Nuclear Information System (INIS)

    Beaumont, B.; Agarici, G.; Gauthier, E.; Kuus, H.; Schlosser, J.

    1994-01-01

    Two generations of Faraday shields for the Tore Supra ICRH antennas interacting with the edge plasma are presented. The last one, using a film of boron carbide as protective material performs well, proving the relevance of this technique for in vessel equipment submitted to low power fluxes. The different lateral protections used on Tore Supra are submitted to high power fluxes. Finite element calculations allow to assess their performances. One type, using Boron Carbide, can be used to measure the local heat flux. The estimation of this flux confirm the specificity of the edge/RF interaction, which is more than one order of magnitude above the exponential decay observed in ohmic plasmas. (author) 11 refs.; 1 fig

  12. Two Solar Tornadoes Observed with the Interface Region Imaging Spectrograph

    Science.gov (United States)

    Yang, Zihao; Tian, Hui; Peter, Hardi; Su, Yang; Samanta, Tanmoy; Zhang, Jingwen; Chen, Yajie

    2018-01-01

    The barbs or legs of some prominences show an apparent motion of rotation, which are often termed solar tornadoes. It is under debate whether the apparent motion is a real rotating motion, or caused by oscillations or counter-streaming flows. We present analysis results from spectroscopic observations of two tornadoes by the Interface Region Imaging Spectrograph. Each tornado was observed for more than 2.5 hr. Doppler velocities are derived through a single Gaussian fit to the Mg II k 2796 Å and Si IV 1393 Å line profiles. We find coherent and stable redshifts and blueshifts adjacent to each other across the tornado axes, which appears to favor the interpretation of these tornadoes as rotating cool plasmas with temperatures of 104 K–105 K. This interpretation is further supported by simultaneous observations of the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory, which reveal periodic motions of dark structures in the tornadoes. Our results demonstrate that spectroscopic observations can provide key information to disentangle different physical processes in solar prominences.

  13. Estimating dispersion from a tornado vortex and mesocyclone

    International Nuclear Information System (INIS)

    Weber, A.H.; Hunter, C.H.

    1996-06-01

    Atmospheric dispersion modeling is required to ensure that a postulated breach in radionuclide storage containers at the Savannah River Site (SRS) from a tornado strike of Fujita-scale intensity F2 or higher will not result in an unacceptable dose to individuals. Fujita-scale tornado descriptions are included in Appendix A of this report. Dispersion models previously used at SRS for estimating dispersion following a tornado strike were developed by D.W. Pepper in 1975 (DP-1387, Dispersion of Small Particles) and H.R. Haynes and D.W. Taylor in 1983 (DPST-82-982, Estimating Doses from Tornado Winds). Research conducted in 1983 on the formation and evolution of tornadic thunderstorms has lead to a more complete understanding of the tornado vortex and associated persistent updraft and downdraft regions within the parent thunderstorm. To ensure that appropriate, contemporary methods are used for safety analysis, the Pepper model and the Haynes and Taylor model were evaluated with respect to current knowledge of circulations within tornadic thunderstorms. Pepper's model is complex numerically but contains most of the desired physical parameterizations. Haynes and Taylor's model is used with the Puff-Plume model (an emergency response model on the Weather INformation and Display System at SRS) and has provisions for radionuclide deposition and rainout. Haynes and Taylor assumed heavy rain following the tornado for a period of ten minutes, followed by a lighter rain for another ten minutes, then no rain for the period when the material is transported to 100 km downwind. However, neither model incorporates the effects of a nearby thunderstorm downdraft

  14. A solar tornado triggered by flares?

    OpenAIRE

    Panesar, N. K.; Innes, D. E.; Tiwari, S. K.; Low, B. C.

    2013-01-01

    Context. Solar tornados are dynamical, conspicuously helical magnetic structures that are mainly observed as a prominence activity. Aims. We investigate and propose a triggering mechanism for the solar tornado observed in a prominence cavity by SDO/AIA on September 25, 2011. Methods. High-cadence EUV images from the SDO/AIA and the Ahead spacecraft of STEREO/EUVI are used to correlate three flares in the neighbouring active-region (NOAA 11303) and their EUV waves with the dynamical de...

  15. A forensic re-analysis of one of the deadliest European tornadoes

    Directory of Open Access Journals (Sweden)

    A. M. Holzer

    2018-06-01

    Full Text Available Extremely rare events with high potential impact, such as violent tornadoes, are of strong interest for climatology and risk assessment. In order to obtain more knowledge about the most extreme events, it is vital to study historical cases. The purpose of this paper is twofold: (1 to demonstrate how a windstorm catastrophe that happened 100 years ago, such as the Wiener Neustadt, Lower Austria, tornado on 10 July 1916, can be successfully re-analyzed using a forensic approach, and (2 to propose a repeatable working method for assessing damage and reconstructing the path and magnitude of local windstorm and tornado cases with sufficient historical sources. Based on the results of the forensic re-analyses, a chronology of the tornado impact is presented, followed by a description of the key tornado characteristics: a maximum intensity rating of F4, a damage path length of 20 km and a maximum visible tornado diameter of 1 km. Compared to a historical scientific study published soon after the event, additional new findings are presented, namely the existence of two predecessor tornadoes and a higher number of fatalities: at least 34 instead of 32. While the storm-scale meteorology could not be reconstructed, rich damage data sources for the urban area of Wiener Neustadt facilitated a detailed analysis of damage tracks and wind intensities within the tornado. The authors postulate the requirement for an International Fujita Scale to rate tornadoes globally in a consistent way, based on comparable damage indicators.

  16. Mortality from a tornado outbreak, Alabama, April 27, 2011.

    Science.gov (United States)

    Chiu, Cindy H; Schnall, Amy H; Mertzlufft, Caitlin E; Noe, Rebecca S; Wolkin, Amy F; Spears, Jeanne; Casey-Lockyer, Mary; Vagi, Sara J

    2013-08-01

    We describe the demographics of the decedents from the tornado outbreak in Alabama on April 27, 2011; examine the circumstances of death surrounding these fatalities; and identify measures to prevent future tornado-related fatalities. We collected information about the decedents from death certificates, disaster-related mortality surveillance, and interview data collected by American Red Cross volunteers from the decedent's families. We describe demographic characteristics, circumstances and causes of death, and sheltering behaviors before death. Of the 247 fatalities, females and older adults were at highest risk for tornado-related deaths. Most deaths were directly related to the tornadoes, on scene, and trauma-related. The majority of the deceased were indoors in single-family homes. Word of mouth was the most common warning mechanism. This tornado event was the third deadliest in recent US history. Our findings support the need for local community shelters, enhanced messaging to inform the public of shelter locations, and encouragement of word-of-mouth warnings and personal and family preparedness planning, with a special focus on assisting vulnerable individuals in taking shelter.

  17. Transport and turbulence in TORE SUPRA ohmic discharges

    International Nuclear Information System (INIS)

    Garbet, X.; Payan, J.; Laviron, C.; Devynck, P.; Saha, S.K.; Capes, H.; Chen, X.P.; Coulon, J.P.; Gil, C.; Harris, G.; Hutter, T.; Pecquet, A.L.

    1992-01-01

    The mechanisms underlying the energy confinement behaviour in ohmic tokamak discharges are not yet understood. It is well known that the confinement time increases with the average density and saturates above a critical value of the density, but several explanations exist for this saturation. The present study is an analysis of a set of ohmic discharges in Tore Supra with I p =1.6 MA, B=4 T, R=2.35 m and a=0.78 m, where the average density was increased from 0.9 to 4.2 10 19 m -3 . For these plasma parameters, the energy confinement time given by magnetic measurements saturates for e > ≥ 2.5 10 19 m -3 . It is emphasized here that the onset of ionic turbulence is unlikely in Tore Supra. This conclusion relies on a transport analysis and turbulence measurements by CO 2 laser scattering, whose results are presented in this paper

  18. School interventions after the Joplin tornado.

    Science.gov (United States)

    Kanter, Robert K; Abramson, David

    2014-04-01

    To qualitatively describe interventions by schools to meet children's needs after the May 2011 Joplin, Missouri tornado. Qualitative exploratory study conducted six months after the tornado. Key informant interviews with school staff (teachers, psychologists, guidance counselor, nurse, principal), public health official, and physicians. After the tornado, school staff immediately worked to contact every enrolled child to provide assistance and coordinate recovery services. Despite severe damage to half of the city's schools, the decision was made to reopen schools at the earliest possible time to provide a safe, reassuring environment and additional services. An expanded summer school session emphasized child safety and emotional wellbeing. The 2011-2012 school year began on time, less than three months after the disaster, using temporary facilities. Displaced children were bused to their usual schools regardless of their new temporary residence locations. In just-in-time training sessions, teachers developed strategies to support students and staff experiencing anxiety or depression. Certified counselors conducted school-based, small-group counseling for students. Selective referrals were made to community mental health providers for children with greatest needs. Evidence from Joplin adds to a small body of empirical experience demonstrating the important contribution of schools to postdisaster community recovery. Despite timely and proactive services, many families and children struggled after the tornado. Improvements in the effectiveness of postdisaster interventions at schools will follow from future scientific evidence on optimal approaches.

  19. Dual-Polarimetric Radar-Based Tornado Debris Paths Associated with EF-4 and EF-5 Tornadoes over Northern Alabama During the Historic Outbreak of 27 April 2011

    Science.gov (United States)

    Carey, Lawrence D.; Schultz, Chrstopher J.; Schultz, Elise V.; Petersen, Walter A.; Gatlin, Patrick N.; Knupp, Kevin R.; Molthan, Andrew L.; Jedlovec, Gary J.; Darden, Christopher B.

    2012-01-01

    An historic tornado and severe weather outbreak devastated much of the southeastern United States between 25 and 28 April 2011. On 27 April 2011, northern Alabama was particularly hard hit by a large number of tornadoes, including several that reached EF-4 and EF-5 on the Enhanced Fujita damage scale. In northern Alabama alone, there were approximately 100 fatalities and hundreds of more people who were injured or lost their homes during the havoc caused by these violent tornadic storms. Two long-track and violent (EF-4 and EF-5) tornadoes occurred within range of the University of Alabama in Huntsville (UAHuntsville) Advanced Radar for Meteorological and Operational Research (ARMOR, C-band dual-polarimetric). A unique capability of dual-polarimetric radar is the near-real time identification of lofted debris associated with ongoing tornadoes on the ground. The focus of this paper is to analyze the dual-polarimetric radar-inferred tornado debris signatures and identify the associated debris paths of the long-track EF-4 and EF-5 tornadoes near ARMOR. The relative locations of the debris and damage paths for each tornado will be ascertained by careful comparison of the ARMOR analysis with NASA MODIS (Moderate Resolution Imaging Spectroradiometer) and ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) satellite imagery of the tornado damage scenes and the National Weather Service tornado damage surveys. With the ongoing upgrade of the WSR-88D (Weather Surveillance Radar 1988 Doppler) operational network to dual-polarimetry and a similar process having already taken place or ongoing for many private sector radars, dual-polarimetric radar signatures of tornado debris promise the potential to assist in the situational awareness of government and private sector forecasters and emergency managers during tornadic events. As such, a companion abstract (Schultz et al.) also submitted to this conference explores The use of dual-polarimetric tornadic debris

  20. Coupling Between Doppler Radar Signatures and Tornado Damage Tracks

    Science.gov (United States)

    Jedlovec, Gary J.; Molthan, Andrew L.; Carey, Lawrence; Carcione, Brian; Smith, Matthew; Schultz, Elise V.; Schultz, Christopher; Lafontaine, Frank

    2011-01-01

    On April 27, 2011, the southeastern United States was raked with several episodes of severe weather. Numerous tornadoes caused extensive damage, and tragically, the deaths of over 300 people. In Alabama alone, there were 61 confirmed tornados, 4 of them produced EF5 damage, and several were on the ground an hour or more with continuous damage tracks exceeding 80km. The use of Doppler radars covering the region provided reflectivity and velocity signatures that allowed forecasters to monitors the severe storms from beginning to end issuing hundreds of severe weather warnings throughout the day. Meteorologists from the the NWS performed extensive surveys to assess the intensity, duration, and ground track of tornadoes reported during the event. Survey activities included site visits to the affected locations, analysis of radar and satellite data, aerial surveys, and interviews with eyewitnesses. Satellite data from NASA's MODIS and ASTER instruments played a helpful role in determining the location of tornado damage paths and in the assessment. High resolution multispectral and temporal composites helped forecasters corroborate their damage assessments, determine starting and ending points for tornado touchdowns, and helped to provide forecasters with a better big-picture view of the damage region. The imagery also helped to separate damage from the April 27th tornados from severe weather that occurred earlier that month. In a post analysis of the outbreak, tornado damage path signatures observed in the NASA satellite data have been correlated to "debris ball" signatures in the NWS Doppler radars and a special ARMOR dual-polarization radar operated by the University of Alabama Huntsville during the event. The Doppler radar data indicates a circular enhanced reflectivity signal and rotational couplet in the radial velocity likely associated with the tornado that is spatially correlated with the damage tracks in the observed satellite data. An algorithm to detect and

  1. Edge plasma control: Particle channeling in Tore Supra pump limiter and ergodic divertor

    International Nuclear Information System (INIS)

    Ghendrih, P.; Samain, A.; Grosman, A.; Capes, H.; Morera, J.P.

    1989-01-01

    Improved pumping efficiency can be achieved on Tore Supra by channeling process for particles, i.e. channeling of neutrals in the throat of pump limiters and channeling of plasma towards neutralizer plates in the ergodic divertor. The plugging length for the pump limiter throat is computed and numerical evidence of plasma flux channeling between the conductor bars of the ergodic divertor is presented. The effect of the Tore Supra ergodic divertor on edge plasma state and edge plasma transport is discussed. (orig.)

  2. A rational method to evaluate tornado-borne missile speed in nuclear power plants. Validation of a numerical code based on Fujita's tornado model

    International Nuclear Information System (INIS)

    Eguchi, Yuzuru; Sugimoto, Soichiro; Hattori, Yasuo; Hirakuchi, Hiromaru

    2015-01-01

    Explanation is given about a rational method to evaluate tornado-borne missile speed, flight distance and flight height to be used for safety design of a nuclear power plant. In the method, the authors employed Fujita's DBT-77 model as a tornado wind model to take the near-ground tornado wind profile into account. A liftoff model of an object on the ground was developed by conservatively modeling the lift force due to ground effect. The wind field model and the liftoff model have been compiled together with a conventional flight model into a computer code, named TONBOS. In this study, especially, the code is verified for one- and two-dimensional free-fall problems as well as a case of 1957 Dallas tornado wind field model, whose solutions are theoretically or numerically known. Finally, the code is validated by typical car behaviors characterized by tornado wind speeds of the enhanced Fujita scale, as well as by an actual event where a truck was blown away by a tornado which struck a part of the town of Saroma, Hokkaido in November, 2006. (author)

  3. Fusion profile measurement on Tore-Supra

    International Nuclear Information System (INIS)

    Martin, G.; Gilles, P.; Joyer, P.

    1990-01-01

    The new diagnostic set on Tore-Supra to observe charged fusion particles is described. The detector is a multiple strip chips and equivalent to 16 small detectors placed close to one another. For given toroidal and poloidal fields, the knowledge of the pitch angle allows to calculate the particle trajectories. The proton flux on the detector is the highest for the most central trajectory. The detector efficiency, resolution and first experimental results are discussed

  4. Tornado-resistance design for the nuclear safety structure of Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Xia Zufeng.

    1987-01-01

    The primary design consideration of anti-tornado of the nuclear safety structure of Qinshan Nuclear Power Plant is briefly presented. It mainly includes estimating the probability of tornado arising in the site, ascertaining the design requirments of the anti-tornado structures and deciding the tornado load acted on the structures

  5. Magnetic traps with a sperical separatrix: Tornado traps

    International Nuclear Information System (INIS)

    Peregood, B.P.; Lehnert, B.

    1979-11-01

    A review is given on the features of magnetic traps with a spherical separatrix, with special emphesis on Tornado spiral coil configurations. The confinement and heating of static plasmas in Tornado traps is treated, including the topology of the magnetic field structure, the magneto-mechanical properties of the magnetic coil system, as well as the particle orbits and plasma behaviour in these traps. In additio, the mode of rotating plasma operation by crossed electric and magnetic fields is being described. The results of experiments on static and rotating plasmas are summarized, and conclusions are drawn about future possibilities of Tornado traps for the creation and containment of hot plasmas. (author)

  6. Magnetic traps with a spherical separatrix: Tornado traps

    International Nuclear Information System (INIS)

    Peregood, B.P.; Lehnert, B.

    1981-01-01

    A review is given on the features of magnetic traps with a spherical separatrix, with special emphasis on Tornado spiral coil configurations. The confinement and heating of static plasms in Tornado traps is treated, including the topology of the magnetic field structure, the magneto-mechanical properties of the magnetic coil system, as well as the particle orbits and plasma behaviour in these traps. In addition, the mode of rotating plasma operation by crossed electric and magnetic fields is described. The results of experiments on static and rotating plasmas are summarized, and conclusions are drawn about future possibilities of Tornado traps in the creation and containment of hot plasmas. (orig.)

  7. Community Post-Tornado Support Groups: Intervention and Evaluation.

    Science.gov (United States)

    McCammon, Susan; And Others

    Post-tornado support groups were organized by the Greene County, North Carolina disaster coordinators and the Pitt County outreach workers from the Community Mental Health Center sponsored tornado follow-up project. The most significant intervention used was the emphasis on creating a climate of group support by establishing a forum for…

  8. Tornado from Texas.

    Science.gov (United States)

    Vail, Kathleen

    1996-01-01

    Santa Fe School Superintendent Yvonne Gonzales, the "Texas Tornado," was hired to fix a 40% student-dropout rate and a white/Hispanic gap in achievement test scores. Gonzales is an avid integrationist; relies on humor, appeasement, and persuasion tactics; and has alienated some school employees by increasing central office…

  9. Tornadoes: A Center Approach.

    Science.gov (United States)

    Christman-Rothlein, Liz; Meinbach, Anita M.

    1981-01-01

    Information is given on how to put together a learning center. Discusses information and activity packets for a complete learning center on tornadoes including objectives, directions, materials, photographs of physical arrangements, and posttest. (DC)

  10. Tore supra first wall conditioning

    International Nuclear Information System (INIS)

    Gauthier, E.; Achard, M.H.; Grosman, A.; Monier, P.

    1989-01-01

    The procedures and the results obtained concerning impurity and isotopic control in Tore Supra tokamak are summarized. The conditioning of the vessel, mainly achieved by glow discharges, is described. The impurity control of the discharge was monitored with a VUV-X spectrometer. The in situ blasting degassing procedure applied is explained. In the sequence of the conditioning process, the hydrogen and the helium glow discharges and the carbonization method are discussed. The He glow discharges allowed to limit the H content of the He plasma shot below 20%

  11. A Bayesian modelling framework for tornado occurrences in North America.

    Science.gov (United States)

    Cheng, Vincent Y S; Arhonditsis, George B; Sills, David M L; Gough, William A; Auld, Heather

    2015-03-25

    Tornadoes represent one of nature's most hazardous phenomena that have been responsible for significant destruction and devastating fatalities. Here we present a Bayesian modelling approach for elucidating the spatiotemporal patterns of tornado activity in North America. Our analysis shows a significant increase in the Canadian Prairies and the Northern Great Plains during the summer, indicating a clear transition of tornado activity from the United States to Canada. The linkage between monthly-averaged atmospheric variables and likelihood of tornado events is characterized by distinct seasonality; the convective available potential energy is the predominant factor in the summer; vertical wind shear appears to have a strong signature primarily in the winter and secondarily in the summer; and storm relative environmental helicity is most influential in the spring. The present probabilistic mapping can be used to draw inference on the likelihood of tornado occurrence in any location in North America within a selected time period of the year.

  12. Preliminar calculation of tornado risk in the site of Ipero

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Rafael R.; Costa, Saulo Barros, E-mail: rafael.rade@ctmsp.mar.mil.br, E-mail: saulo.costa@ctmsp.mar.mil.br [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil); Andrade, Delvonei A., E-mail: delvonei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    General Design Criterion (GDC) 2 to 10 CFR 50 requires that 'structures, systems, and components that are important to safety shall be designed to withstand the effects of natural phenomena, such as tornadoes, without loss of capability to perform their safety functions'. According to Regulatory Guide 1.76, the design-basis intensity of a tornado for a nuclear power plant shall not exceed the intensity of the strongest tornado that occurs with the frequency of 10-7/years. Reinforcing the plant to achieve this goal represents a high increase in the costs of the project, and correspondently increase in the time required to have it commissioned. This way, the right definition of tornado risk in a site would represent savings in money for the project and in time for the licensing of a nuclear power plants. This works aims to establish a preliminary calculation of the tornado risk in the site of Ipero, where will work LABGENE from Brazilian Navy, and RMB from CNEN. (author)

  13. The assessment of tornado missile hazard to nuclear power plants

    International Nuclear Information System (INIS)

    Goodman, J.; Koch, J.E.

    1983-01-01

    Numerical methods and computer codes for assessing tornado missile hazards to nuclear power plants are developed. Due to the uncertainty and randomness of tornado and tornado-generated missiles' characteristics, the damage probability of targets has a highly spread distribution. The proposed method is useful for assessing the risk of not providing protection to some nonsafety-related targets whose failure can create a hazard to the safe operation of nuclear power plants

  14. An Analysis of Operational Total Lightning Data During Long-Track Tornadoes

    Science.gov (United States)

    Carcione, Brian C.; Stano, Geoffrey T.

    2012-01-01

    The 27 April 2011 tornado outbreak brought three distinct waves of tornadic thunderstorms to portions of Mississippi, Alabama, Tennessee, and Georgia, striking the Tennessee Valley of north Alabama and southern Tennessee particularly hard. A total of 42 tornado paths were surveyed across the fourteen county area covered by the National Weather Service (NWS) forecast office in Huntsville, Alabama. Ten of these tornadoes were on the ground for at least 20 miles, two had total path lengths over 130 miles, and six tornadoes were classified as violent (EF-4 or EF-5 on the Enhanced Fujita Scale). Many of these tornadoes occurred within the domain of the North Alabama Lightning Mapping Array (NALMA), a ground-based total lightning detection network owned and operated by the NASA Marshall Space Flight Center. Since 2003, the NASA Short-term Prediction Research and Transition Center has supplied data from NALMA in real time to NWS forecast offices in Huntsville, Knoxville/Tri-Cities, Birmingham, and Nashville. Previous research has documented the utility of total lightning information in predicting tornadogenesis, particularly when combined with other remote sensing tools. Basic warning decision-making during events such as 27 April is not the most difficult part of the process; instead, the focus of warning meteorologists shifts to looking for changes in intensity or possible particularly dangerous situations, since doppler radar velocity data often cannot distinguish between weak and strong tornadoes. To that end, this research attempts to determine if any correlation exists between flash densities of the longest-tracked tornadoes over time, and the surveyed wind speeds of the tornadoes. The long-track EF-5 tornado which struck the Hackleburg, Phil Campbell, and Tanner communities in north Alabama was the primary focus of this research due to its intensity and extended life cycle. However, not all tornadoes were available for total lightning analysis due to widespread

  15. Tornadoes and related damage costs: statistical modelling with a semi-Markov approach

    Directory of Open Access Journals (Sweden)

    Guglielmo D’Amico

    2016-09-01

    Full Text Available We propose a statistical approach to modelling for predicting and simulating occurrences of tornadoes and accumulated cost distributions over a time interval. This is achieved by modelling the tornado intensity, measured with the Fujita scale, as a stochastic process. Since the Fujita scale divides tornado intensity into six states, it is possible to model the tornado intensity by using Markov and semi-Markov models. We demonstrate that the semi-Markov approach is able to reproduce the duration effect that is detected in tornado occurrence. The superiority of the semi-Markov model as compared to the Markov chain model is also affirmed by means of a statistical test of hypothesis. As an application, we compute the expected value and the variance of the costs generated by the tornadoes over a given time interval in a given area. The paper contributes to the literature by demonstrating that semi-Markov models represent an effective tool for physical analysis of tornadoes as well as for the estimation of the economic damages to human things.

  16. Long pulse operation on Tore Supra

    International Nuclear Information System (INIS)

    Monier-Garbet, P.

    2004-01-01

    This document gathers a series of transparencies dedicated to the long pulse operation on Tore-Supra. The structure of the document is described as follows: the first part is an introduction recalling fusion basis and presenting the different physical and technological phenomenon time scales. The second part is dedicated to the production of long pulses through non-inductive drive and some experimental scenarios illustrate it. The final part is devoted to physics issues like particle retention

  17. Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Malinowski, K.; Mirowski, R.; Lotte, Ph.; Gunn, J.; Pascal, J-Y.; Colledani, G.; Basiuk, V.; Goniche, M.; Lipa, M.

    2010-01-01

    The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

  18. Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Malinowski, K.; Mirowski, R. [Andrzej Soltan Institute for Nuclear Studies (IPJ), Otwock-Swierk 05-400 (Poland); Lotte, Ph.; Gunn, J.; Pascal, J-Y.; Colledani, G.; Basiuk, V.; Goniche, M.; Lipa, M. [CEA, IRFM, St Paul-lez-Durance F-13108 (France)

    2010-01-15

    The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

  19. Electrical Characteristics of Simulated Tornadoes and Dust Devils

    Science.gov (United States)

    Zimmerman, Michael I.; Farrell, William M.; Barth, E. L.; Lewellen, W. S.; Perlongo, N. J.; Jackson, T. L.

    2012-01-01

    It is well known that tornadoes and dust devils have the ability to accumulate significant, visible clouds of debris. Collisions between sand-like debris species produce different electric charges on different types of grains, which convect along different trajectories around the vortex. Thus, significant charge separations and electric currents are possible, which as the vortex fluctuates over time are thought to produce ULF radiation signatures that have been measured in the field. These electric and magnetic fields may contain valuable information about tornado structure and genesis, and may be critical in driving electrochemical processes within dust devils on Mars. In the present work, existing large eddy simulations of debris-laden tornadoes performed at West Virginia University are coupled with a new debris-charging and advection code developed at Goddard Space Flight Center to investigate the detailed (meter-resolution) fluid-dynamic origins of electromagnetic fields within terrestrial vortices. First results are presented, including simulations of the electric and magnetic fields that would be observed by a near-surface, instrument-laden probe during a direct encounter with a tornado.

  20. Vulnerability Assessment of the nuclear power plant Vandellos II before a tornado; Evaluacion de vulnerabilidad de C.N. Vandellos II ante tornado

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A.; Encabo, J.; Vaz-Romero, A.; Moran, M. A.; Roch, M.; Nicolas, P.; Barrera, N.

    2010-07-01

    The purpose of this work was the study of vulnerability to tornado event Vandellos II NPP. To do this, we have evaluated all structures (buildings), security systems and components to the installation of wind stresses, depression and impact of projectiles, generated by a tornado on the site.

  1. Assessment guide for tornado effect on Nuclear Power Plants (draft) with its commentaries

    International Nuclear Information System (INIS)

    Inoue, Hiroto; Fukunishi, Shiro; Suzuki, Tetsuo

    2013-10-01

    In the context of a severe accident at the Fukushima Daiichi Nuclear Power Station (NPS) operated by the Tokyo Electric Power Company (TEPCO) due to the 2011 off the Pacific coast of Tohoku Earthquake and Tsunami, Nuclear Regulation Authority (NRA) was established on September 19, 2012 under the relevant law. After that NRA organized a task force for studying new regulatory standards for nuclear power plants (NPPs) in consideration of lessons learned from the severe accident at Fukushima. In the task force open meeting, through discussing about design basis external natural events which should be considered in the new regulatory standards, tornado was newly introduced into new regulatory standards as an external natural event. Based on the decision that tornado was newly introduced into new regulatory standards, the Secretariat of the Nuclear Regulation Authority (SNRA) commissioned the Japan Nuclear Energy Safety Organization (JNES) to study an assessment guide for tornado effect on NPPs intended to be used for an official safety review for a NPP construction. JNES organized Sectional Committee for Tornado Effect Assessment Guide consisting of experts in meteorology and wind engineering fields, discussing about assessment methods for tornado effect on NPPs, draft version of the assessment guide for tornado effect on NPPs was completed on April 4, 2013, and JNES submitted the draft guide to SNRA on the same date. After that NRA called for public comments for the draft version of the assessment guide, the draft version of the assessment guide was partly amended taking posted public comments account, and tornado effect assessment guide was officially released on June 19, 2013. Contents in this paper are as follows, assessment guide for tornado effect on NPPs (Draft version on April 4, 2013), supplementary documents, calculation examples, and future tasks for further improved reliability of tornado effect assessment on NPPs. This draft guide consists of six chapters

  2. Assessment guide for tornado effect on Nuclear Power Plants (draft) with its commentaries

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Hiroto; Fukunishi, Shiro; Suzuki, Tetsuo [Japan Nuclear Energy Safety Organization, Seismic Safety Department, Tokyo (Japan)

    2013-10-15

    In the context of a severe accident at the Fukushima Daiichi Nuclear Power Station (NPS) operated by the Tokyo Electric Power Company (TEPCO) due to the 2011 off the Pacific coast of Tohoku Earthquake and Tsunami, Nuclear Regulation Authority (NRA) was established on September 19, 2012 under the relevant law. After that NRA organized a task force for studying new regulatory standards for nuclear power plants (NPPs) in consideration of lessons learned from the severe accident at Fukushima. In the task force open meeting, through discussing about design basis external natural events which should be considered in the new regulatory standards, tornado was newly introduced into new regulatory standards as an external natural event. Based on the decision that tornado was newly introduced into new regulatory standards, the Secretariat of the Nuclear Regulation Authority (SNRA) commissioned the Japan Nuclear Energy Safety Organization (JNES) to study an assessment guide for tornado effect on NPPs intended to be used for an official safety review for a NPP construction. JNES organized Sectional Committee for Tornado Effect Assessment Guide consisting of experts in meteorology and wind engineering fields, discussing about assessment methods for tornado effect on NPPs, draft version of the assessment guide for tornado effect on NPPs was completed on April 4, 2013, and JNES submitted the draft guide to SNRA on the same date. After that NRA called for public comments for the draft version of the assessment guide, the draft version of the assessment guide was partly amended taking posted public comments account, and tornado effect assessment guide was officially released on June 19, 2013. Contents in this paper are as follows, assessment guide for tornado effect on NPPs (Draft version on April 4, 2013), supplementary documents, calculation examples, and future tasks for further improved reliability of tornado effect assessment on NPPs. This draft guide consists of six chapters

  3. Pellet injection and confinement in the tore supra tokamak; Injection de glacons et confinement dans le tokamak tore supra

    Energy Technology Data Exchange (ETDEWEB)

    Maget, P

    1998-09-23

    Pellet injection in the centre of tokamak plasmas can lead to an improved confinement regime called PEP (Pellet Enhanced Performance). The present work is dedicated to the mechanisms involved in the PEP regimes obtained in the tokamak Tore Supra. A neoclassical approach of transport shows that it is the anomalous transport, due to plasma turbulence, that causes the enhanced confinement. A linear model describing electrostatic instabilities has been developed in order to study the roles of density profile and current profile during the PEP, in the limit of large growth rates. The effect ofradial shear in flows is taken into account by removing the ExB shear flow rate from the linear growth rate, as suggested by non-linear numerical simulations of turbulence. A local transport coefficient is estimated from the knowledge of the linear growth rate and the mode width. We find that the peaked density profile in PEP regime lowers the diffusion coefficient, and that the velocity shear amplifies this effect. The evolution of the current profile is also stabilizing, but this parameter is not known with sufficient accuracy, so that its role in Tore Supra PEP experiments remains uncertain. (author)

  4. The occurrence of a tornado in Serbia on 31 march 2013

    Directory of Open Access Journals (Sweden)

    Pavlovic-Berdon Nada

    2013-01-01

    Full Text Available Tornado occurs very rarely in the territory of Serbia. The occurrence of a tornado above Torda (Vojvodina, Serbia on 31 March 2013 indicted the importance of monitoring such a dangerous weather phenomenon, knowing its characteristics and forecasting it. This paper analyzes the synoptic conditions and vertical structure of the atmosphere that prevailed during the development of a supercell with a tornado. Changes in temperature and air pressure are presented on mesoscale maps. The analysis was performed by using the Nonhydrostatic Mesoscale Model (NMM. The tornado occurrence was monitored via satellite images and radar characteristics of a supercell. The cause of tornadogenesis has been ascertained. According to the EF scale, the tornado reached F0 intensity. Damages to roofs, power lines, trees and cars caused by the wind (>35ms-1 are also presented.

  5. Teacher Guidelines for Helping Students after a Tornado

    Science.gov (United States)

    National Child Traumatic Stress Network, 2013

    2013-01-01

    Being in a tornado can be very frightening, and the days, weeks, and months following the storm can be very stressful. Most families recover over time, especially with the support of relatives, friends, and their community. But different families may have different experiences during and after a tornado, and how long it takes them to recover will…

  6. Tornadoes and waterspouts in Catalonia (1950-2009)

    OpenAIRE

    Gayà, M.; Llasat Botija, María del Carmen; Arús Dumenjó, Joan

    2011-01-01

    This paper presents a preliminary climatology of tornadoes and waterspouts in Catalonia (NE Iberian Peninsula). A database spanning 60 yr (1950–2009) has been developed on the basis of information collected from various sources such as weather reports, insurance companies, newspapers and damage surveys. This database has been subjected to a rigorous validation process, and the climatology describes its main features: timing, spatial pattern, and trends in the tornado and wat...

  7. An experimental investigation of wind pressures on square pillars in tornado-like vortices

    International Nuclear Information System (INIS)

    Iwatani, Yoshiharu; Maruta, Eizou; Kanda, Makoto; Hattori, Yousuke; Hamano, Naoki; Matsuura, Takeshi

    1992-01-01

    This report describes a laboratory simulation of tornado-like vortices and laboratory measurements of steady wind loads on model structures in tornado-like vortices. The variations of wind direction and wind speed of tornado-like vortices and ground surface pressure under tornado-like vortices with the swirl ratio, Reynolds number and the surface roughness were investigated. Wind pressure distributions on square pillars were measured in tornado-like vortices. It was observed in the experiment that the negative pressures on the roof faces of square pillars were high and distributed rather uniformly but these on the side faces differed greatly from place to place and locally became high. The high pressure regions on the side faces were close to ground surface in the case where the model structures stood in the center of tornado-like vortex, and became higher as the increase of distance between the model structures and the center of tornado-like vortices. (author)

  8. AM05-13-009 Experimental simulation of non-supercell tornadoes

    OpenAIRE

    佐々, 浩司; Koji, Sassa; 高知大理; Kochi Univ.

    2005-01-01

    The non-supercell tornadoes was experimentally simulated by the combination of the gust made of dry ice and the updraft fan. Three typical patterns of tornadoes were observed in relation to the change of updraft velocity. These patterns are a laminar vortex, a turbulent vortex and a spiral vortex. The resultant tornadoes were found to move with the updraft fan. They broke down when the moving velocity was larger than the mean velocity in the shear line.

  9. Numerical modelling of pump limiter biasing on TEXTOR-94 and Tore Supra

    International Nuclear Information System (INIS)

    Gerhauser, H.; Claassen, H.A.; Mank, G.; Zagorski, R.; Loarer, T.; Gunn, J.; Boucher, C.

    2002-01-01

    The two-dimensional multifluid code TECXY has been used to model the biasing (with respect to the first wall) of the toroidal belt limiter ALT-II on the tokamak TEXTOR-94 and of the new toroidal pump limiter being installed on Tore Supra tokamak in the framework of the CIEL project. It is well known that the edge flow pattern can be influenced by the poloidal electric drifts from imposing radial electric fields. The modelling with TECXY introduces imprinted bias currents in the scrape-off layer (SOL) for the case of negative (limiter) biasing, and imprinted bias potentials for the case of positive biasing. This allowed us to simulate sufficiently well the experimental I-V characteristics for either biasing of ALT-II and also reproduced the essential features and trends of the observed plasma profiles in the SOL of TEXTOR-94. For negative biasing a moderate improvement of the pumping exhaust efficiency can be achieved in the case of TEXTOR. For Tore Supra, however, only a negligible improvement of the limiter performance with biasing can be predicted, which is explained by the relatively weak drift flows in Tore Supra. (author)

  10. Tornadoes in Canada for the period 1950 to 1979

    International Nuclear Information System (INIS)

    Newark, M.J.

    1981-06-01

    This report has attempted to arrive at a set of quantitative conclusions concerning the physical characteristics of tornadoes from what is basically a set of qualitative data. The task was composed of a number of steps: a) finding the data in the first place, b) defining the terms and equations to be used in the study, c) devising a method of dealing with the errors and inconsistencies in the data, d) encoding it into a quantitative form, e) computerizing the encoded data for ease of sorting and calculation, and f) analyzing the result. The results of the study give details concerning the physical dimensions of tornado damage; national maps of tornado incidence and risk; probability of tornado damage in selected cities; diurnal and seasonal frequencies as well as frequencies of travel direction and F-scale number; length of tornado season. An analysis has been made of the distribution of damage length, width and area in order to find whether or not correlations exist among them, and whether or not they can be described in a mathematical fashion. No correlations were found, and although the distributions of these dimensions superficially resembled a log normal curve, this result failed to be statistically significant

  11. Tornadoes and waterspouts in Catalonia (1950–2009

    Directory of Open Access Journals (Sweden)

    M. Gayà

    2011-07-01

    Full Text Available This paper presents a preliminary climatology of tornadoes and waterspouts in Catalonia (NE Iberian Peninsula. A database spanning 60 yr (1950–2009 has been developed on the basis of information collected from various sources such as weather reports, insurance companies, newspapers and damage surveys. This database has been subjected to a rigorous validation process, and the climatology describes its main features: timing, spatial pattern, and trends in the tornado and waterspout distribution. Results show the highest concentration of tornadoes from August to October, the highest density in the heavily populated coastal areas and a growing positive trend that is likely more closely linked to an increase in observation and perception rather than a real climatic trend.

  12. Tore-Supra infrared thermography system, a real steady-state diagnostic

    International Nuclear Information System (INIS)

    Guilhem, D.; Bondil, J.L.; Bertrand, B.; Desgranges, C.; Lipa, M.; Messina, P.; Missirlian, M.; Portafaix, C.; Reichle, R.; Roche, H.; Saille, A.

    2005-01-01

    Tore-Supra Tokamak (I p = 1.5 MA, B t = 4 T) has been constructed with a steady-state magnetic field using super-conducting magnets and water-cooled plasma facing components (PFCs) for high-performance long pulse plasma discharges. When not actively cooled, plasma facing components can only accumulate a limited amount of energy since the temperature increases continuously during the discharge until radiation cooling equals the incoming heat flux. Such an environment is found in the JET Tokamak [JET Team, IAEA-CN-60/A1-3, Seville, 1994] and on TRIAM [M. Sakamoto, H. Nakashima, S. Kawasaki, A. Iyomasa, S.V. Kulkarni, M. Hasegawa, E. Jotaki, H. Zushi, K. Nakamura, K. Hanada, S. Itoh, Static and dynamic properties of wall recycling in TRIAM-1M, J. Nucl. Mater. 313-316 (2003) 519-523] [Y. Kamada, et al., Nucl. Fusion 3 (1999) 1845]. In Tore-Supra, the surface temperature of the actively cooled plasma facing components reach steady state within a second. We present here the Tore-Supra thermographic system, made of seven endoscope bodies equipped so far with eight infrared (IR) cameras. It has to be noted that this diagnostic is the first diagnostic to be actively cooled, as required for steady state. The main purpose of such a diagnostic is to prevent the plasma to damage the actively cooled plasma facing components (ACPFCs), which consist of the toroidal pumped limiter (TPL), 7 m 2 , and of five radio-frequency antennae, 1.5 m 2 each

  13. TORE SUPRA vacuum vessel and shield manufacturing

    International Nuclear Information System (INIS)

    Blateyron, J.; Lepez, R.

    1984-01-01

    TORE SUPRA vacuum vessel and vacuum chamber shield manufacturing in progress at Jeumont-Schneider consists of three main phases: - Detail engineering and manufacturing fixture construction; - Prototype section manufacturing and process preparation; - Construction of the 6 production modules. The welding techniques adopted, call for three special automatic processes: TIG, MIG and PLASMA welding which guarantee mechanical strength, vacuum tightness and absence of distortion. Production of the modules began July 1984. (author)

  14. Electron cyclotron emission measurement in Tore Supra

    International Nuclear Information System (INIS)

    Javon, C.

    1991-06-01

    Electron cyclotron radiation from Tore-Supra is measured with Michelson and Fabry-Perot interferometers. Calibration methods, essential for this diagnostic, are developed allowing the determination of electron temperature in the plasma. In particular the feasibility of Fabry-Perot interferometer calibration by an original method is demonstrated. A simulation code is developed for modelling non-thermal electron population in these discharges using measurements in non-inductive current generation regime [fr

  15. First results of the Tore Supra ITER like ICRF antenna prototype

    International Nuclear Information System (INIS)

    Vulliez, K.; Bosia, G.; Bremond, S.; Agarici, G.; Beaumont, B.; Lombard, G.; Millon, L.; Mollard, P.; Volpe, D.

    2005-01-01

    The project of an ITER-like (IL) ion cyclotron (IC) prototype antenna was initiated in mid 2002 in Cadarache, to assess the operational characteristics of the IL scheme in a Tore Supra (TS)-sized array. The prototype was developed by modifying an existing Tore Supra resonant double loop (RDL) antenna. This strategy, chosen to reduce cost and manufacturing time, allowed the completion of the array construction at the end of 2003. The array was installed on TS in January 2004, at the beginning of the new experimental campaign. After a few comments on the design, the paper reports results on low-power characterisation, high-power commissioning and preliminary tests on TS plasmas, prior to the array dis-assembly for inspection

  16. MHD activity triggered by monster sawtooth crashes on Tore Supra

    International Nuclear Information System (INIS)

    Maget, P; Artaud, J-F; Eriksson, L-G; Huysmans, G; Lazaros, A; Moreau, P; Ottaviani, M; Segui, J-L; Zwingmann, W

    2005-01-01

    The crash of monster sawteeth in Tore Supra ion cyclotron resonance heated plasmas is observed to trigger long-lived magneto hydrodynamic (MHD) activity, dominated by a (m = 3, n = 2) magnetic perturbation at the edge. This phenomenon is reminiscent of the triggering of neoclassical tearing modes, although in Tore Supra the MHD activity decays and eventually vanishes. It can be explained by the linear destabilization of the (3, 2) mode as the current sheet developed in the non-linear stage of the internal kink relaxation gets closer to q = 3/2. However, the lifetime of the (3, 2) island is longer than the period of linear instability. We find that the neoclassical drive is essential for explaining the observed lifetime and width of the island, although the overall dynamics is controlled by the relaxation of the current profile on a resistive time scale

  17. The recollective qualities of adolescents' and adults' narratives about a long-ago tornado.

    Science.gov (United States)

    Bauer, Patricia J; Stark, Emily N; Ackil, Jennifer K; Larkina, Marina; Merrill, Natalie; Fivush, Robyn

    2017-03-01

    The recollective qualities of autobiographical memory are thought to develop over the course of the first two decades of life. We used a 9-year follow-up test of recall of a devastating tornado and of non-tornado-related events from before and after the storm, to compare the recollective qualities of adolescents' (n = 20, ages 11 years, 11 months to 20 years, 8 months) and adults' (n = 14) autobiographical memories. At the time of the tornado, half of the adolescents had been younger than age 6. Nine years after the event, all participants provided evidence that they recall the event of the tornado. Adults also had high levels of recall of the non-tornado-related events. Adolescents recalled proportionally fewer non-tornado-related events; adolescents younger than 6 at the time of the events recalled the fewest non-tornado-related events. Relative to adolescents, adults produced longer narratives. With narrative length controlled, there were few differences in the recollective qualities of adolescents' and adults' narrative reports, especially in the case of the tornado; the recollective qualities were stronger among adolescents older at the time of the events. Overall, participants in both age groups provided evidence of the qualities of recollection that are characteristic of autobiographical memory.

  18. Assessment of the bases for selecting criteria for protection against tornado-entrained debris

    International Nuclear Information System (INIS)

    Read, J.B.J.; Bell, L.W.

    1977-05-01

    The probabilities and consequences of the acceleration of solid objects by air motion within a tornado are discussed, in order to assess the risks of damage from tornado missiles. Design criteria for protection against tornado missile risks are suggested

  19. Wind pressure testing of tornado safe room components made from wood

    Science.gov (United States)

    Robert Falk; Deepak Shrestha

    2016-01-01

    To evaluate the ability of a wood tornado safe room to resist wind pressures produced by a tornado, two safe room com-ponents were tested for wind pressure strength. A tornado safe room ceiling panel and door were static-pressure-tested according to ASTM E 330 using a vacuum test system. Re-sults indicate that the panels had load capacities from 2.4 to 3.5 times that...

  20. Data on rotating plasma operation in Tornado traps

    International Nuclear Information System (INIS)

    Lehnert, B.

    1976-01-01

    Rotating plasma operation in spiral coil 'Tornado' traps provides a unique combination of confinement and heating properties. Such a system consists of a closed and compact magnetic bottle to which the crossed-field technique can be applied, in absence of end insulators and their critical velocity limitation effect. This should make possible the generation and heating of fully ionized plasmas by simple means, within a large range of ion densities, temperatures, and rotational velocities. Provided that stable operation becomes possible at high temperatures, it is likely that Tornado traps can be used as strong neutron sources of moderately large dimensions and technically realizable parameter values. Some detailed data and operation ranges are given for the 'Tornado 650' device in Leningrad, and for a somewhat larger device to be operated as neutron source. (Auth.)

  1. Full-scale tornado-missile impact tests. Interim report

    International Nuclear Information System (INIS)

    Stephenson, A.E.

    1976-04-01

    Seven completed initial tests are described with 4 types of hypothetical tornado-borne missiles (impacting reinforced concrete panels that are typical of walls in nuclear power facilities). The missiles were rocket propelled to velocities currently postulated as being attainable by debris in tornadoes. (1500-pound 35-foot long utility pole; 8-pound 1-inch Grade 60 reinforcing bar; 78-pound 3-inch Schedule 40 pipe; and 743-pound 12-inch Schedule 40 pipe;) The results show that a minimum thickness of 24 inches is sufficient to prevent backface scabbing from normal impacts of currently postulated tornado missiles and that existing power plant walls are adequate for the most severe conditions currently postulated by regulatory agencies. This report gives selected detailed data on the tests completed thus far, including strain, panel velocity, and reaction histories

  2. Residential tornado safe room from commodity wood products – design and development

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell

    2018-01-01

    In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms have helped decrease the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a nonproprietary residential tornado safe...

  3. Spatially resolved charge exchange flux calculations on the Toroidal Pumped Limiter of Tore Supra

    International Nuclear Information System (INIS)

    Marandet, Y.; Tsitrone, E.; Boerner, P.; Reiter, D.; Beaute, A.; Delchambre, E.; Escarguel, A.; Brezinsek, S.; Genesio, P.; Gunn, J.; Monier-Garbet, P.; Mitteau, R.; Pegourie, B.

    2009-01-01

    A spatially resolved calculation of the charge exchange particle and energy fluxes on the Toroidal Pumped Limiter (TPL) of Tore Supra is presented, as a first step towards a better understanding and modelling of carbon erosion, migration, as well as deuterium codeposition and bulk diffusion of deuterium in Tore Supra. The results are obtained with the EIRENE code run in a 3D geometry. Physical and chemical erosion maps on the TPL are calculated, and the contribution of neutrals to erosion, especially in the self-shadowed area, is calculated.

  4. The Tore Supra HeII cryogenic system

    International Nuclear Information System (INIS)

    Claudet, G.

    1991-01-01

    The tokamak TORE SUPRA built by the association EURATOM-CEA is routinely operated with a toroidal magnet made of Niobium Titanium cooled at 1.8 K by pressurized HeII. The paper will remind the reasons for such a choice and will describe the corresponding technical solutions. After several years of operation, the validity of the HeII cooling solution will be discussed on the basis of the actual and long term behaviour

  5. An experimental investigation of flow around a vehicle passing through a tornado

    Science.gov (United States)

    Suzuki, Masahiro; Obara, Kouhei; Okura, Nobuyuki

    2016-03-01

    Flow around a vehicle running through a tornado was investigated experimentally. A tornado simulator was developed to generate a tornado-like swirl flow. PIV study confirmed that the simulator generates two-celled vortices which are observed in the natural tornadoes. A moving test rig was developed to run a 1/40 scaled train-shaped model vehicle under the tornado simulator. The car contained pressure sensors, a data logger with an AD converter to measure unsteady surface pressures during its run through the swirling flow. Aerodynamic forces acting on the vehicle were estimated from the pressure data. The results show that the aerodynamic forces change its magnitude and direction depending on the position of the car in the swirling flow. The asymmetry of the forces about the vortex centre suggests the vehicle itself may deform the flow field.

  6. An experimental investigation of flow around a vehicle passing through a tornado

    Directory of Open Access Journals (Sweden)

    Suzuki Masahiro

    2016-01-01

    Full Text Available Flow around a vehicle running through a tornado was investigated experimentally. A tornado simulator was developed to generate a tornado-like swirl flow. PIV study confirmed that the simulator generates two-celled vortices which are observed in the natural tornadoes. A moving test rig was developed to run a 1/40 scaled train-shaped model vehicle under the tornado simulator. The car contained pressure sensors, a data logger with an AD converter to measure unsteady surface pressures during its run through the swirling flow. Aerodynamic forces acting on the vehicle were estimated from the pressure data. The results show that the aerodynamic forces change its magnitude and direction depending on the position of the car in the swirling flow. The asymmetry of the forces about the vortex centre suggests the vehicle itself may deform the flow field.

  7. Numerical simulation of tornado-borne missile impact

    International Nuclear Information System (INIS)

    Tu, D.K.; Murray, R.C.

    1977-01-01

    The feasibility of using a finite element procedure to examine the impact phenomenon of a tornado-borne missile impinging on a reinforced concrete barrier was assessed. The major emphasis of this study was to simulate the impact of a nondeformable missile. Several series of simulations were run, using an 8-in.-dia steel slug as the impacting missile. The numerical results were then compared with experimental field tests and empirical formulas. The work is in support of tornado design practices for fuel reprocessing and fuel fabrication plants

  8. Simulation of core turbulence measurement in Tore Supra ohmic regimes

    NARCIS (Netherlands)

    Hacquin, S.; Citrin, J.; Arnichand, H.; Sabot, R.; Bourdelle, C.; Garbet, X.; Kramer-Flecken, A.; Tore Supra team,

    2016-01-01

    This paper reports on a simulation of reflectometry measurement in Tore Supra ohmic discharges, for which the experimental observations as well as gyrokinetic non-linear computations predict a modification of turbulence spectrum between the linear (LOC) and the saturated ohmic confinement (SOC)

  9. DYNAMICS OF A SOLAR PROMINENCE TORNADO OBSERVED BY SDO/AIA ON 2012 NOVEMBER 7–8

    Energy Technology Data Exchange (ETDEWEB)

    Mghebrishvili, Irakli; Zaqarashvili, Teimuraz V.; Kukhianidze, Vasil; Ramishvili, Giorgi [Abastumani Astrophysical Observatory at Ilia State University, University St. 2, Tbilisi, Georgia (United States); Shergelashvili, Bidzina [Space Research Institute, Austrian Academy of Sciences, Schmiedlstrasse 6, A-8042 Graz (Austria); Veronig, Astrid [IGAM-Kanzelhöhe Observatory, Institute of Physics, University of Graz, Universitätsplatz 5, A-8010 Graz (Austria); Poedts, Stefaan, E-mail: teimuraz.zaqarashvili@oeaw.ac.at [Centre for Mathematical Plasma Astrophysics, Celestijnenlaan 200B, B-3001 Leuven (Belgium)

    2015-09-10

    We study the detailed dynamics of a solar prominence tornado using time series of 171, 304, 193, and 211 Å spectral lines obtained by the Solar Dynamics Observatory/Atmospheric Imaging Assembly during 2012 November 7–8. The tornado first appeared at 08:00 UT, November 07, near the surface, gradually rose upwards with the mean speed of ∼1.5 km s{sup −1} and persisted over 30 hr. Time–distance plots show two patterns of quasi-periodic transverse displacements of the tornado axis with periods of 40 and 50 minutes at different phases of the tornado evolution. The first pattern occurred during the rising phase and can be explained by the upward motion of the twisted tornado. The second pattern occurred during the later stage of evolution when the tornado already stopped rising and could be caused either by MHD kink waves in the tornado or by the rotation of two tornado threads around a common axis. The later hypothesis is supported by the fact that the tornado sometimes showed a double structure during the quasi-periodic phase. 211 and 193 Å spectral lines show a coronal cavity above the prominence/tornado, which started expansion at ∼13:00 UT and continuously rose above the solar limb. The tornado finally became unstable and erupted together with the corresponding prominence as coronal mass ejection (CME) at 15:00 UT, November 08. The final stage of the evolution of the cavity and the tornado-related prominence resembles the magnetic breakout model. On the other hand, the kink instability may destabilize the twisted tornado, and consequently prominence tornadoes can be used as precursors for CMEs.

  10. Particles pumping in Tore Supra

    International Nuclear Information System (INIS)

    Bonnel, P.; Chappuis, P.; Lipa, M.

    1989-01-01

    TORE SUPRA and its peripheral equipments are provided with routine clean high vacuum by turbomolecular pumping. During plasma discharges large quantity of very hot gases activating at plasma edge and plasma density in scrape off layer has to be controlled before they strike violently solid wall provoking increase in impurities content and make density up to disruptive level. A Magnetic Ergodic Divertor made of six winding structures - MED - six Vertical Pumped Limiters - VPL - and one Horizontal Pumped Limiter - HPL - are set in the vacuum chamber in order to cope with plasma-wall interactions and neutral gas recycling. Each apparatus is equipped at front side with thermal shield respectively made of polycristallin and pyrolitic graphite bolted on stainless steel support for MED and HPL whereas for VPL it is made of CFC Aerolor 05 brazed on hardened copper. The total heat removal capacity of these plasma facing components is 12 MW. Design of particles collection openings and ducts conductance allow 10% of capture efficiency, that means for TORE SUPRA a flux of 3 x 10 21 particles/second has to be sorbed by water cooled titanium getter pumps, settled at rear side. All those facilities were put into plasma operation at the beginning of 1989 for a short time. Preliminary observations go along with theoretical predictions, that actions in scrappe-off layer may provoke effects in bulk plasma. Very first results drawn out, show that particle collection and heat removal were effective by MED, VPL and HPL and that plasma behaviour was not disturbed by their presence and actions but instead tendency to improvement was observed

  11. The Tore Supra control, computer system : six years of operation and improvements

    International Nuclear Information System (INIS)

    Journeaux, J.Y.; Badie, O.; Chatelier, E.; Hennion, F.; Lebourg, P.; Leveque, P.; Hernandez, M.; Moulin, D.

    1995-01-01

    The Tore Supra control computer system has been providing a good operation of the Tore Supra machine for six years. It controls all of the sub-systems, the continuous ones as well as the sequential ones, and the automatic operation is very efficient. The control system has been programmed by the users themselves thanks to its user-friendly qualities, in order to keep the full control and knowledge of the automatisms. Nevertheless, some improvements are now necessary. Their main principles are : to choose ergonomic and powerful tools, industrial standards, and to keep the users's participation. The whole control system will be upgraded : the automatism level as well as the display level and the communication networks. The operator's driving job is analysed as supervisory and diagnostic tasks which have an effect on the Tore Supra machine efficiency. So a very powerful driving software has been chosen and linked with an expert system, which is to be designed and implemented with the aim to give an immediate accurate and global understanding of the process and situations, in particular in case of trouble. The method is based on an artificial intelligence approach, and it exploits both the process' informations and automatisms' steps, to determine the process state, next possible states and diagnosis of the process troubles. (orig.)

  12. Articulated inspection arm for ITER, a demonstration in the Tore Supra tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Cordier, J.J.; Gargiulo, L.; Grisolia, C.; Samaille, F. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Friconneau, J.P.; Perrot, Y. [CEA Fontenay-aux-Roses, LIST Robotics and Interactive Systems Unit, 92 (France); Palmer, J.D. [Max-Planck-Institut fuer Plasmaphysik Boltzmannstr.2, Garching (Germany)

    2003-07-01

    The aim of this program is to demonstrate for ITER the feasibility of an in-vessel remote handling inspection using a long reach, limited payload carrier (1 to 10 kg) for penetration of the ITER chamber through the openings. This device is dedicated to close inspection of the Plasma Facing Components (PFC). An articulated demonstrator called articulated inspection arm (AIA) has been manufactured. A feasibility study of a full AIA operation in Tore Supra was performed, taking into account ITER reference requirements. A scale one demonstration of the AIA under ITER relevant condition is feasible on Tore Supra and would give significant improvement in research results for ITER remote Handling equipment. The test of the AIA demonstrator behaviour is foreseen in 2005 in real Tokamak conditions. The paper presents the full robot concept, the results of the first test campaign, the AIA new design and its integration on Tore Supra. Several potential uses of the AIA for the in vessel components inspection are being studied such as PFC visual inspection, water loop leak testing, laser ablation for wall detritiation and carbon dust and flakes removal are foreseen as utilities to be placed at the AIA head. These various systems are described in the paper.

  13. Articulated inspection arm for ITER, a demonstration in the Tore Supra tokamak

    International Nuclear Information System (INIS)

    Cordier, J.J.; Gargiulo, L.; Grisolia, C.; Samaille, F.; Palmer, J.D.

    2003-01-01

    The aim of this program is to demonstrate for ITER the feasibility of an in-vessel remote handling inspection using a long reach, limited payload carrier (1 to 10 kg) for penetration of the ITER chamber through the openings. This device is dedicated to close inspection of the Plasma Facing Components (PFC). An articulated demonstrator called articulated inspection arm (AIA) has been manufactured. A feasibility study of a full AIA operation in Tore Supra was performed, taking into account ITER reference requirements. A scale one demonstration of the AIA under ITER relevant condition is feasible on Tore Supra and would give significant improvement in research results for ITER remote Handling equipment. The test of the AIA demonstrator behaviour is foreseen in 2005 in real Tokamak conditions. The paper presents the full robot concept, the results of the first test campaign, the AIA new design and its integration on Tore Supra. Several potential uses of the AIA for the in vessel components inspection are being studied such as PFC visual inspection, water loop leak testing, laser ablation for wall detritiation and carbon dust and flakes removal are foreseen as utilities to be placed at the AIA head. These various systems are described in the paper

  14. Tornado Protection: Selecting and Designing Safe Areas in Buildings.

    Science.gov (United States)

    Abernethy, James J.

    Tornadoes and extreme winds cause heavy loss of life and property damage throughout the United States. Most buildings offer significant protection from this danger, and building administrators should know the areas where this protection is available. This booklet presents a review of three schools, all of which were struck by tornadoes on April 3,…

  15. Doppler Radar and Lightning Network Observations of a Severe Outbreak of Tropical Cyclone Tornadoes

    Science.gov (United States)

    Mccaul, Eugene W., Jr.; Buechler, Dennis E.; Goodman, Steven J.; Cammarata, Michael

    2004-01-01

    Data from a single Weather Surveillance Radar-1988 Doppler (WSR-88D) and the National Lightning Detection Network are used to examine the characteristics of the convective storms that produced a severe tornado outbreak, including three tornadoes that reached F3 intensity, within Tropical Storm Beryl s remnants on 16 August 1994. Comparison of the radar data with reports of tornadoes suggests that only 13 cells produced the 29 tornadoes that were documented in Georgia and the Carolinas on that date. Six of these cells spawned multiple tornadoes, and the radar data confirm the presence of miniature supercells. One of the cells was identifiable on radar for 11 h. spawning tornadoes over a time period spanning approximately 6.5 h. Several other tornadic cells also exhibited great longevity, with cell lifetimes longer than ever previously documented in a landfalling tropical cyclone (TC) tornado event. This event is easily the most intense TC tornado outbreak yet documented with WSR-88Ds. Time-height analyses of the three strongest tornadic supercells are presented in order to document storm kinematic structure and to show how these storms appear at different ranges from a WSR-88D. In addition, cloud-to-ground (CG) lightning data are examined in Beryl s remnants. Although the tornadic cells were responsible for most of Beryl's CG lightning, their flash rates were only weak to moderate, and in all the tornadic storms the lightning flashes were almost entirely negative in polarity. A few of the single-tornado storms produced no detectable CG lightning at all. There is evidence that CG lightning rates decreased during the tornadoes, compared to 30-min periods before the tornadoes. A number of the storms spawned tornadoes just after producing their final CG lightning flashes. Contrary to the findings for flash rates, both peak currents and positive flash percentages were larger in Beryl's nontornadic storms than in the tornadic ones.

  16. Comprehensive analysis of tornado statistics in comparison to earthquakes: intensity and temporal behaviour

    Directory of Open Access Journals (Sweden)

    L. Schielicke

    2013-01-01

    Full Text Available Tornadoes and earthquakes are characterised by a high variability in their properties concerning intensity, geometric properties and temporal behaviour. Earthquakes are known for power-law behaviour in their intensity (Gutenberg–Richter law and temporal statistics (e.g. Omori law and interevent waiting times. The observed similarity of high variability of these two phenomena motivated us to compare the statistical behaviour of tornadoes using seismological methods and quest for power-law behaviour. In general, the statistics of tornadoes show power-law behaviour partly coextensive with characteristic scales when the temporal resolution is high (10 to 60 min. These characteristic scales match with the typical diurnal behaviour of tornadoes, which is characterised by a maximum of tornado occurrences in the late afternoon hours. Furthermore, the distributions support the observation that tornadoes cluster in time. Finally, we shortly discuss a possible similar underlying structure composed of heterogeneous, coupled, interactive threshold oscillators that possibly explains the observed behaviour.

  17. Spatial Distributions of Tropical Cyclone Tornadoes by Intensity and Size Characteristics

    OpenAIRE

    Todd W. Moore; Nicholas J. Sokol; Robert A. Blume

    2017-01-01

    Tropical cyclones that make landfall often spawn tornadoes. Previous studies have shown that these tornadoes are not uniformly distributed in the United States or in the tropical cyclone environment. They show that tornadoes tend to occur relatively close to the coastline and that they tend to cluster to the east-of-center in the tropical cyclone environment, particularly in the northeast and east-of-center quadrants. This study contributes to these studies by analyzing the spatial distributi...

  18. Latest climate changes in Romania :tornadoes

    Science.gov (United States)

    Pop, Elena

    2014-05-01

    Latest climate changes in Romania :tornadoes As climate change has been considered a research priority in the European Strategy for enduring development , I have done a detailed research with my students of the new climate change that has been going on in Romania for the past decade. More precisely I have studied together with my students the phenomenon of tornadoes that have seriously affected on some occasions some our our country's locations, such as Facaeni, in the county of Ialomita, in August 2002. A quite unusual phenomenon occurred on that location situated at 44.56 degrees northern latitude and at 27.89 degrees eastern longitude, that caused severe damage to the local environment and three persons lost their lives in the process, as well as other thirty people suffering from bad injuries. The magnitude of that strong phenomenon rose on the Fujita scale at level F3 which implied wing gusts between 252-300 km/ hour . A main cause of occurrence of such a severe weather was the difference in temperature of two huge air masses, one of Polar origin, and other coming from tropical latitudes . Their crossroads was on that precise territory of Romania. The duration of the worst part of the tornado path lasted only for two minutes, but the consequences of its passage were colossal : total destruction of 33 households, and other 395 were partially damaged, 1,000 people afflicted by the devastation and 100 acres of acacia tree forest ripped off the ground. The first ever recorded tornado phenomenon in Romania was around 1894-1896, considered at that time " a freak of nature" was seen as a cloud formation abnormality , an uncontrolled force of nature that had a huge impact , and at the same time, it vanished into "thin air " fast. The most affected areas in Romania by tornadoes are the south-eastern planes where the cloud formations can create fast columns of air rotating up to 500 km/hour. The local people compared the cloud funnels created on the planes to "serpents

  19. Apophysomyces trapeziformis infection associated with a tornado-related injury.

    Science.gov (United States)

    Weddle, Gina; Gandy, Kimberly; Bratcher, Denise; Pahud, Barbara; Jackson, Mary Anne

    2012-06-01

    This report defines the role of Apophysomyces as an aggressive fungal pathogen seen after a tornado injury. Clinical and laboratory manifestations of infections after environmentally contaminated wounds incurred during a tornado are outlined, emphasizing mechanism of injury, comorbidities, and diagnostic and treatment challenges. Therapy with systemic antifungal therapy and aggressive serial tissue debridement was successful in achieving cure.

  20. Engineering studies for the installation of an axi-symmetric metallic divertor in Tore Supra

    International Nuclear Information System (INIS)

    Doceul, L.; Portafaix, C.; Bucalossi, J.; Saille, A.; Bertrand, B.; Lipa, M.; Missirlian, M.; Jiolat, G.; Samaille, F.; Soler, B.

    2011-01-01

    Tore Supra (TS) has been designed to operate using technologies that allow long plasma operation (a few minutes), by means of superconducting magnets and actively-cooled high heat flux plasma facing components (PFCs). Actively cooled tungsten PFC will be used in the baffle area of the first ITER divertor. In order to validate such a technology fully (industrial manufacturing, operation with long plasma duration), the implementation of a tungsten axi-symmetric divertor in the tokamak Tore Supra has been studied . With this second major upgrade, Tore Supra should be able to address the problematic of long plasma discharges with a metallic divertor. The proposed divertor is made up of two stainless steel casings containing a copper coil winding located at the top and bottom area of the vacuum vessel. These casings are firmly maintained by connection beams and protected by PFC. This paper describes the mechanical design of this major component and its integration in TS, the associated electromagnetic and thermomechanical analysis, the manufacturing issues and finally the integration of ITER representative PFCs.

  1. An evaluation method for tornado missile strike probability with stochastic correction

    Energy Technology Data Exchange (ETDEWEB)

    Eguchi, Yuzuru; Murakami, Takahiro; Hirakuchi, Hiromaru; Sugimoto, Soichiro; Hattori, Yasuo [Nuclear Risk Research Center (External Natural Event Research Team), Central Research Institute of Electric Power Industry, Abiko (Japan)

    2017-03-15

    An efficient evaluation method for the probability of a tornado missile strike without using the Monte Carlo method is proposed in this paper. A major part of the proposed probability evaluation is based on numerical results computed using an in-house code, Tornado-borne missile analysis code, which enables us to evaluate the liftoff and flight behaviors of unconstrained objects on the ground driven by a tornado. Using the Tornado-borne missile analysis code, we can obtain a stochastic correlation between local wind speed and flight distance of each object, and this stochastic correlation is used to evaluate the conditional strike probability, QV(r), of a missile located at position r, where the local wind speed is V. In contrast, the annual exceedance probability of local wind speed, which can be computed using a tornado hazard analysis code, is used to derive the probability density function, p(V). Then, we finally obtain the annual probability of tornado missile strike on a structure with the convolutional integration of product of QV(r) and p(V) over V. The evaluation method is applied to a simple problem to qualitatively confirm the validity, and to quantitatively verify the results for two extreme cases in which an object is located just in the vicinity of or far away from the structure.

  2. An evaluation method for tornado missile strike probability with stochastic correction

    International Nuclear Information System (INIS)

    Eguchi, Yuzuru; Murakami, Takahiro; Hirakuchi, Hiromaru; Sugimoto, Soichiro; Hattori, Yasuo

    2017-01-01

    An efficient evaluation method for the probability of a tornado missile strike without using the Monte Carlo method is proposed in this paper. A major part of the proposed probability evaluation is based on numerical results computed using an in-house code, Tornado-borne missile analysis code, which enables us to evaluate the liftoff and flight behaviors of unconstrained objects on the ground driven by a tornado. Using the Tornado-borne missile analysis code, we can obtain a stochastic correlation between local wind speed and flight distance of each object, and this stochastic correlation is used to evaluate the conditional strike probability, QV(r), of a missile located at position r, where the local wind speed is V. In contrast, the annual exceedance probability of local wind speed, which can be computed using a tornado hazard analysis code, is used to derive the probability density function, p(V). Then, we finally obtain the annual probability of tornado missile strike on a structure with the convolutional integration of product of QV(r) and p(V) over V. The evaluation method is applied to a simple problem to qualitatively confirm the validity, and to quantitatively verify the results for two extreme cases in which an object is located just in the vicinity of or far away from the structure

  3. Prepare to protect: Operating and maintaining a tornado safe room.

    Science.gov (United States)

    Herseth, Andrew; Goldsmith-Grinspoon, Jennifer; Scott, Pataya

    2017-06-01

    Operating and maintaining a tornado safe room can be critical to the effective continuity of business operations because a firm's most valuable asset is its people. This paper describes aspects of operations and maintenance (O&M) for existing tornado safe rooms as well as a few planning and design aspects that affect the ultimate operation of a safe room for situations where a safe room is planned, but not yet constructed. The information is based on several Federal Emergency Management Agency safe room publications that provide guidance on emergency management and operations, as well as the design and construction of tornado safe rooms.

  4. Millimeter-wave molecular line observations of the Tornado nebula

    International Nuclear Information System (INIS)

    Sakai, D.; Oka, T.; Tanaka, K.; Matsumura, S.; Miura, K.; Takekawa, S.

    2014-01-01

    We report the results of millimeter-wave molecular line observations of the Tornado Nebula (G357.7-0.1), which is a bright radio source behind the Galactic center region. A 15' × 15' area was mapped in the J = 1-0 lines of CO, 13 CO, and HCO + with the Nobeyama Radio Observatory 45 m telescope. The Very Large Array archival data of OH at 1720 MHz were also reanalyzed. We found two molecular clouds with separate velocities, V LSR = –14 km s –1 and +5 km s –1 . These clouds show rough spatial anti-correlation. Both clouds are associated with OH 1720 MHz emissions in the area overlapping with the Tornado Nebula. The spatial and velocity coincidence indicates violent interaction between the clouds and the Tornado Nebula. Modestly excited gas prefers the position of the Tornado 'head' in the –14 km s –1 cloud, also suggesting the interaction. Virial analysis shows that the +5 km s –1 cloud is more tightly bound by self-gravity than the –14 km s –1 cloud. We propose a formation scenario for the Tornado Nebula; the +5 km s –1 cloud collided into the –14 km s –1 cloud, generating a high-density layer behind the shock front, which activates a putative compact object by Bondi-Hoyle-Lyttleton accretion to eject a pair of bipolar jets.

  5. First results of the ECE measurements on Tore Supra

    International Nuclear Information System (INIS)

    Garcin, M.; Javon, C.; Laurent, L.; Masset, R.; Rodriguez, L.; Talvard, M.

    1989-01-01

    Since the beginning of the Tore Supra experiments in april 1988, the ECE diagnostic has been partially operated. The main elements of the diagnostic have been tested and first results have been obtained with a Michelson interferometer and a vertical array of antennae. According to the latter arrangement, the first inverted emissivity profiles are presented

  6. Annual and seasonal tornado activity in the United States and the global wind oscillation

    Science.gov (United States)

    Moore, Todd W.

    2018-06-01

    Previous studies have searched for relationships between tornado activity and atmospheric teleconnections to provide insight on the relationship between tornadoes, their environments, and larger scale patterns in the climate system. Knowledge of these relationships is practical because it can improve seasonal and sub-seasonal predictions of tornado probability and, therefore, help mitigate tornado-related losses. This study explores the relationships between the annual and seasonal tornado activity in the United States and the Global Wind Oscillation. Time series herein show that phases of the Global Wind Oscillation, and atmospheric angular momentum anomalies, vary over a period of roughly 20-25 years. Rank correlations indicate that tornado activity is weakly correlated with phases 2, 3, and 4 (positive) and 6, 7, and 8 (negative) of the Global Wind Oscillation in winter, spring, and fall. The correlation is not as clear in summer or at the annual scale. Non-parametric Mann-Whitney U tests indicate that winters and springs with more phase 2, 3, and 4 and fewer phase 6, 7, and 8 days tend to have more tornadoes. Lastly, logistic regression models indicate that winters and springs with more phase 2, 3, and 4 days have greater likelihoods of having more than normal tornado activity. Combined, these analyses suggest that seasons with more low atmospheric angular momentum days, or phase 2, 3, and 4 days, tend to have greater tornado activity than those with fewer days, and that this relationship is most evident in winter and spring.

  7. Annual and seasonal tornado activity in the United States and the global wind oscillation

    Science.gov (United States)

    Moore, Todd W.

    2017-08-01

    Previous studies have searched for relationships between tornado activity and atmospheric teleconnections to provide insight on the relationship between tornadoes, their environments, and larger scale patterns in the climate system. Knowledge of these relationships is practical because it can improve seasonal and sub-seasonal predictions of tornado probability and, therefore, help mitigate tornado-related losses. This study explores the relationships between the annual and seasonal tornado activity in the United States and the Global Wind Oscillation. Time series herein show that phases of the Global Wind Oscillation, and atmospheric angular momentum anomalies, vary over a period of roughly 20-25 years. Rank correlations indicate that tornado activity is weakly correlated with phases 2, 3, and 4 (positive) and 6, 7, and 8 (negative) of the Global Wind Oscillation in winter, spring, and fall. The correlation is not as clear in summer or at the annual scale. Non-parametric Mann-Whitney U tests indicate that winters and springs with more phase 2, 3, and 4 and fewer phase 6, 7, and 8 days tend to have more tornadoes. Lastly, logistic regression models indicate that winters and springs with more phase 2, 3, and 4 days have greater likelihoods of having more than normal tornado activity. Combined, these analyses suggest that seasons with more low atmospheric angular momentum days, or phase 2, 3, and 4 days, tend to have greater tornado activity than those with fewer days, and that this relationship is most evident in winter and spring.

  8. Tornado frequency in the USA - meteorological and non-meteorological factors of a downward trend

    Directory of Open Access Journals (Sweden)

    Mihajlović Jovan

    2015-01-01

    Full Text Available Citing numerical simulations, climate alarmists believe that global warming will lead to more frequent and more intensive tornadoes. Considering temperature increase data in the contiguous USA, this study has investigated the trend of strong tornadoes in F3+ category in the 1954-2012 period. Statistically significant decrease of tornadoes per year at an average rate of 0.44 has been recorded, that is, 4.4 tornadoes per decade. Tornado increase has been recorded with F0 and F1 categories and the cause of this increase lies in meteorological and non-meteorological factors. By using upper and lower standard deviation values, the stages of tornado activity have been singled out. The 1957-1974 period may be considered as an active stage and the 1978-2009 period as an inactive stage. Upward trend of air temperature increase does not correspond with the downward trend of the number of F3+ tornado category, while the correlation coefficient between these two variables is R = −0.14. This fact does not correspond with the simulation results and output data of various numerical models anticipating an increase in the number and intensity of tornado events in the conditions of surface air temperature growth.

  9. Infrared reflection properties and modelling of in situ reflection measurements on plasma-facing materials in Tore Supra

    International Nuclear Information System (INIS)

    Reichle, R; Desgranges, C; Faisse, F; Pocheau, C; Lasserre, J-P; Oelhoffen, F; Eupherte, L; Todeschini, M

    2009-01-01

    Tore Supra has-like ITER-reflecting internal surfaces, which can perturb the machine protection systems based on infrared (IR) thermography. To ameliorate this situation, we have measured and modelled in the 3-5 μm wavelength range the bi-directional reflection distribution function (BRDF) of wall material samples from Tore Supra and conducted in situ reflection measurements and simulated them with the CEA COSMOS code. BRDF results are presented for B 4 C and carbon fibre composite (CFC) tiles. The hemispherical integrated reflection ranges from 0.12 for the B 4 C sample to 0.39 for a CFC tile from the limiter erosion zone. In situ measurements of the IR reflection of a blackbody source off an ICRH and an LHCD antenna of Tore Supra are well reproduced by the simulation.

  10. Infrared reflection properties and modelling of in situ reflection measurements on plasma-facing materials in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Reichle, R; Desgranges, C; Faisse, F; Pocheau, C [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Lasserre, J-P; Oelhoffen, F; Eupherte, L; Todeschini, M [CEA, DAM, CESTA, F-33114 Le Barp (France)

    2009-12-15

    Tore Supra has-like ITER-reflecting internal surfaces, which can perturb the machine protection systems based on infrared (IR) thermography. To ameliorate this situation, we have measured and modelled in the 3-5 {mu}m wavelength range the bi-directional reflection distribution function (BRDF) of wall material samples from Tore Supra and conducted in situ reflection measurements and simulated them with the CEA COSMOS code. BRDF results are presented for B{sub 4}C and carbon fibre composite (CFC) tiles. The hemispherical integrated reflection ranges from 0.12 for the B{sub 4}C sample to 0.39 for a CFC tile from the limiter erosion zone. In situ measurements of the IR reflection of a blackbody source off an ICRH and an LHCD antenna of Tore Supra are well reproduced by the simulation.

  11. ASSESSMENT OF TORNADOS WITH THE ENHANCED FUJITA SCALE IN ROMANIA

    Directory of Open Access Journals (Sweden)

    C. NUCUŢĂ

    2011-03-01

    Full Text Available Assessment of tornadoes with the Enhanced Fujita Scale in Romania. An analysis of the damage caused by a tornado, in order to determine the maximum wind speed that was reached, is important both in terms of documenting the phenomenon and to make improvements to the evaluation method which is used, especially if this method is not specific for the analyzed territory. An overview of the way the tornado from Silivaşu de Câmpie, on the 26th of May 2010, was termed EF2 is done to summarize the difficulties that arise in the assessment of tornadoes occurring in Romania with the Enhanced Fujita scale. The lack of correlation between damage indicators, different construction styles and building materials between those in the United States and those selected in this case study are the main issues addressed. Solutions for these issues are discussed as a starting point for the adjustment of Enhanced Fujita scale for Romania.

  12. Schools in Kansas with Tornado Protection. Shawnee Mission Public Schools--District No. 512.

    Science.gov (United States)

    Ward, Delbert B.

    Kansas and nearby Missouri are among the half-dozen states in America having the greatest frequency of tornadoes of any region in the world. This booklet describes a districtwide approach of designing and constructing tornado-resistant shelters as integrated parts of the school facilities. The design criteria for tornado protection also resulted…

  13. Differential pressures on building walls during tornados

    International Nuclear Information System (INIS)

    Yeh, G.C.K.

    1975-01-01

    In the United States, containment structures and some auxiliary structures (control building, auxiliary building, spent fuel building, etc.) in nuclear power plants are required to be designed to withstand the effects of the design basis tornado. In addition to velocity pressures and missile impact a tornado also gives rise to a rapid change in atmospheric pressure, which can, in cases of closed or partially vented structures, produce direct differential pressure loading. In this paper a digital computer program is described which applies a tornado-induced, time-dependent atmospheric pressure change to a building and calculates the differential pressure histories across the interior and exterior walls of the building. Laws for quasi-steady, one-dimensional motion of an ideal compressible gas are used to calculate the pressures due to the flow of air through ports, doors and windows in the building. Numerical examples show that for each assumed atmospheric pressure change history a vent area to compartment volume ratio may be specified as the criterion for a building to be considered fully vented. (orig.) [de

  14. Tornado missile simulation and risk analysis

    International Nuclear Information System (INIS)

    Twisdale, L.A.; Dunn, W.L.; Chu, J.

    1978-01-01

    Mathematical models of the contributing events to the tornado missile hazard at nuclear power plants have been developed in which the major sources of uncertainty have been considered in a probabilistic framework. These models have been structured into a sequential event formalism which permits the treatment of both single and multiple missile generation events. A simulation computer code utilizing these models has been developed to obtain estimates of tornado missile event likelihoods. Two case studies have been analyzed; the results indicate that the probability of a single missile from the sampling population impacting any of the plant's targets is less then about 10 -7 per reactor-year. Additional work is needed for verification and sensitivity study

  15. MHD limits in non-inductive tokamak plasmas: simulations and comparison to experiments on Tore Supra

    International Nuclear Information System (INIS)

    Maget, P.; Huysmans, G.; Ottaviani, M.; Garbet, X.; Moreau, Ph.; Segui, J.-L.; Luetjens, H.

    2008-01-01

    Non-inductive tokamak discharges with a flat or hollow current profile are prone to the triggering of large tearing modes when the minimum of the safety factor is just below a low order rational. This issue is of particular importance for discussing the optimal safety factor for MHD modes avoidance in Steady-State reactor plasmas. Different non-linear regimes of such magnetic configurations in Tore Supra are studied using the full MHD code XTOR. Numerical simulations show that the non-linear stage of the Double-Tearing Mode (DTM) is governed by the full reconnection model, but a single tearing mode in a low magnetic shear configuration can have a similar impact on the confinement. The different regimes observed experimentally are recovered in the simulations: a small amplitude (2,1) DTM for close resonant surfaces as seen in Tore Supra, a sawtooth-like behaviour of the (2,1) Double-Tearing Mode as first seen in TFTR, or a large amplitude (2,1) tearing mode that severely degrades the energy confinement, as reported in Tore Supra, JET or DIII-D. Situations where q min ≅1.5 with a stable n = 1 mode, as seen in Tore Supra longest discharges, seem to put specific constraints on the MHD model that is used. Indeed, curvature stabilisation without transport terms as could explain linear stability, but such effect vanishes in presence of heat transport. Electron diamagnetic rotation effect is investigated as a possible mechanism for n = 1 mode stabilization.

  16. Tore supra: towards the 'long time' fusion. Press journey

    International Nuclear Information System (INIS)

    2008-01-01

    After a recall of the interest in the fusion for the development of energy sources, the document presents the fusion from the solar reaction to the nuclear fusion in laboratory. Then it discusses the great challenges of this technology and the Tore Supra installation. The last part is devoted to ITER and DEMO projects. (A.L.B.)

  17. Data on rotating plasma operation in Tornado traps

    International Nuclear Information System (INIS)

    Lehnert, B.

    1977-01-01

    Rotating plasma operation in spiral coil 'Tornado' traps provides a unique combination of confinement and heating properties. Such a system consists of a closed and compact magnetic bottle to which the crossed-field technique can be applied, in absence of end insulators and their critical velocity limitation effect. This is expected to lead to the generation and heating of fully ionized plasmas within a large range of ion densities, temperatures, and rotational velocities. Provided that stable operation becomes possible at high temperatures and the effects due to the asymmetries of the spiral coil structure can be neglected, it is likely that Tornado traps can be used as strong neutron sources of moderately large dimensions and technically realizable parameter values. Some detailed data and operation ranges are outlined for the 'Tornado 650' device in Leningrad, and for a somewhat larger device which may be operated as a neutron source. (Auth.)

  18. Tornado outbreak variability follows Taylor's power law of fluctuation scaling and increases dramatically with severity.

    Science.gov (United States)

    Tippett, Michael K; Cohen, Joel E

    2016-02-29

    Tornadoes cause loss of life and damage to property each year in the United States and around the world. The largest impacts come from 'outbreaks' consisting of multiple tornadoes closely spaced in time. Here we find an upward trend in the annual mean number of tornadoes per US tornado outbreak for the period 1954-2014. Moreover, the variance of this quantity is increasing more than four times as fast as the mean. The mean and variance of the number of tornadoes per outbreak vary according to Taylor's power law of fluctuation scaling (TL), with parameters that are consistent with multiplicative growth. Tornado-related atmospheric proxies show similar power-law scaling and multiplicative growth. Path-length-integrated tornado outbreak intensity also follows TL, but with parameters consistent with sampling variability. The observed TL power-law scaling of outbreak severity means that extreme outbreaks are more frequent than would be expected if mean and variance were independent or linearly related.

  19. Tornado outbreak variability follows Taylor's power law of fluctuation scaling and increases dramatically with severity

    Science.gov (United States)

    Tippett, Michael K.; Cohen, Joel E.

    2016-01-01

    Tornadoes cause loss of life and damage to property each year in the United States and around the world. The largest impacts come from ‘outbreaks' consisting of multiple tornadoes closely spaced in time. Here we find an upward trend in the annual mean number of tornadoes per US tornado outbreak for the period 1954–2014. Moreover, the variance of this quantity is increasing more than four times as fast as the mean. The mean and variance of the number of tornadoes per outbreak vary according to Taylor's power law of fluctuation scaling (TL), with parameters that are consistent with multiplicative growth. Tornado-related atmospheric proxies show similar power-law scaling and multiplicative growth. Path-length-integrated tornado outbreak intensity also follows TL, but with parameters consistent with sampling variability. The observed TL power-law scaling of outbreak severity means that extreme outbreaks are more frequent than would be expected if mean and variance were independent or linearly related. PMID:26923210

  20. Ion Temperature Measurements in the Tore Supra Scrape-Off Layer Using a Retarding Field Analyzer

    International Nuclear Information System (INIS)

    Kocan, M.; Gunn, J.P.; Pascal, J.Y.; Gauthier, E.

    2010-01-01

    The retarding field analyzer (RFA) is one of the only widely accepted diagnostics for measuring the ion temperature T i )in the tokamak scrape-off layer. An overview of the outstanding RFA performance over ten years of operation in Tore Supra tokamak is given and the validation of T i measurements is addressed. The RFA measurements in Tore Supra are found to be well reproducible. The ion-to-electron temperature ratio is higher than one at low-to-moderate ion-electron collisionality regime and converges to unity at high collisionality regime. (authors)

  1. Production and control of an edge radiating layer with the ergodic divertor on TORE SUPRA

    International Nuclear Information System (INIS)

    Poutchy, L.; Vallet, J.C.; Michelis, C. de; Grosman, A.; Hess, W.; Mattioli, M.; Monier-Garbet, P.

    1992-01-01

    We have recently defined on Tore Supra a discharge piloting strategy to prevent disruptions at the density limit, based on the property of the Ergodic Divertor to stabilize MHD activity. This strategy allows plasma studies close to the density limit without disruptions, and has been successfully used on Tore Supra ohmicly heated plasmas. The Ergodic Divertor allows also the stabilization of detached plasmas which appear spontaneously near the density limit. Edge impurities are shown to play a fundamental role in this stabilization. Detached plasmas have been thereby controlled during 10 seconds

  2. Tore supra: towards the 'long time' fusion. Press journey; Tore Supra: vers la fusion 'longue duree'. Voyage de presse

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    After a recall of the interest in the fusion for the development of energy sources, the document presents the fusion from the solar reaction to the nuclear fusion in laboratory. Then it discusses the great challenges of this technology and the Tore Supra installation. The last part is devoted to ITER and DEMO projects. (A.L.B.)

  3. The February 21, 1993 tornadoes of East Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, K.E.; Kornegay, F.C. [Martin Marietta Energy Systems, Inc., Oak Ridge, TN (United States)

    1993-08-11

    A series of tornadoes struck the east Tennessee area on Sunday afternoon, February 21, 1993 around Knoxville, Lenoir City, and Oak Ridge causing millions of dollars worth of damage to both homes and businesses in the area, killing one, injuring a number of persons, and leaving a large area without power for many hours or even days due to damage to the local TVA transmission line network. One tornado touched down in the Department of Energy Oak Ridge Reservation near the Oak Ridge Y-12 Plant, continued through the Union Valley business district located just east of the plant, through the adjacent University of Tennessee Arboretum and then continued into the communities of Claxton and Powell. The path length of the tornado was approximately 13 miles. Damage to the Y-12 Plant was minimal, but the Union Valley business district was seriously damaged, including the Fusion Energy Design Center (FEDC) which houses a number of DOE related projects. The preliminary cost estimate of the damage to DOE facilities (both at Y-12 and at the FEDC) was around $520,000. This paper describes the local meteorological data, the tornado that struck near the Y-12 plant, the resulting damage both to the DOE facilities and to the surrounding communities, the plant emergency response and recovery activities, and the current hazard analyses being undertaken at the plant.

  4. Two-phase flows in the formed tornado funnel

    Science.gov (United States)

    Sinkevich, O. A.; Bortsova, A. A.

    2017-10-01

    At present, it is obvious that the problem of the tornado is important not only for our planetЮ to determine the conditions for the formation of a tornado, it is required to take into account a number of hydrodynamic and plasma processes [1 - 6]. Along to prediction of a tornado generation conditions [1 - 3] it is necessary to evaluate the characteristics of its quasi-stationary motion in a formed funnel: the mass of the moving moist air involved in the funnel and the size and form of the funnel. For a complete description of the phenomena, it is necessary to involve numerical calculations. We note that even for numerical calculations using powerful computers, the problem is very difficult because of the need to calculate multiphase turbulent flows with free, self-organizing boundaries [1, 6]. However, “strict” numerical calculations, it is impossible to do without the use of many, often mutually exclusive, models. For example, how to choice an adequate model of turbulence (algebraic, k-ε model, etc.) or the use of additional, often not accepted, hypotheses about certain processes used in calculations (mechanisms on the nature of moisture condensation, etc.). Therefore, along with numerical calculations of such flows, modeling problems that allow an exact solution and allow to determine the most important and observed characteristics of a tornado.

  5. Why do tornados and hailstorms rest on weekends?

    Science.gov (United States)

    Rosenfeld, Daniel; Bell, Thomas L.

    2011-10-01

    This study shows for the first time statistical evidence that when anthropogenic aerosols over the eastern United States during summertime are at their weekly mid-week peak, tornado and hailstorm activity there is also near its weekly maximum. The weekly cycle in summertime storm activity for 1995-2009 was found to be statistically significant and unlikely to be due to natural variability. It correlates well with previously observed weekly cycles of other measures of storm activity. The pattern of variability supports the hypothesis that air pollution aerosols invigorate deep convective clouds in a moist, unstable atmosphere, to the extent of inducing production of large hailstones and tornados. This is caused by the effect of aerosols on cloud drop nucleation, making cloud drops smaller and hydrometeors larger. According to simulations, the larger ice hydrometeors contribute to more hail. The reduced evaporation from the larger hydrometeors produces weaker cold pools. Simulations have shown that too cold and fast-expanding pools inhibit the formation of tornados. The statistical observations suggest that this might be the mechanism by which the weekly modulation in pollution aerosols is causing the weekly cycle in severe convective storms during summer over the eastern United States. Although we focus here on the role of aerosols, they are not a primary atmospheric driver of tornados and hailstorms but rather modulate them in certain conditions.

  6. The February 21, 1993 tornadoes of East Tennessee

    International Nuclear Information System (INIS)

    Fricke, K.E.; Kornegay, F.C.

    1993-01-01

    A series of tornadoes struck the east Tennessee area on Sunday afternoon, February 21, 1993 around Knoxville, Lenoir City, and Oak Ridge causing millions of dollars worth of damage to both homes and businesses in the area, killing one, injuring a number of persons, and leaving a large area without power for many hours or even days due to damage to the local TVA transmission line network. One tornado touched down in the Department of Energy Oak Ridge Reservation near the Oak Ridge Y-12 Plant, continued through the Union Valley business district located just east of the plant, through the adjacent University of Tennessee Arboretum and then continued into the communities of Claxton and Powell. The path length of the tornado was approximately 13 miles. Damage to the Y-12 Plant was minimal, but the Union Valley business district was seriously damaged, including the Fusion Energy Design Center (FEDC) which houses a number of DOE related projects. The preliminary cost estimate of the damage to DOE facilities (both at Y-12 and at the FEDC) was around $520,000. This paper describes the local meteorological data, the tornado that struck near the Y-12 plant, the resulting damage both to the DOE facilities and to the surrounding communities, the plant emergency response and recovery activities, and the current hazard analyses being undertaken at the plant

  7. Millimeter-wave molecular line observations of the Tornado nebula

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, D. [Department of Astronomy, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Oka, T.; Tanaka, K.; Matsumura, S.; Miura, K.; Takekawa, S., E-mail: sakai.daisuke@nao.ac.jp [Department of Physics, Institute of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama, Kanagawa 223-8522 (Japan)

    2014-08-10

    We report the results of millimeter-wave molecular line observations of the Tornado Nebula (G357.7-0.1), which is a bright radio source behind the Galactic center region. A 15' × 15' area was mapped in the J = 1-0 lines of CO, {sup 13}CO, and HCO{sup +} with the Nobeyama Radio Observatory 45 m telescope. The Very Large Array archival data of OH at 1720 MHz were also reanalyzed. We found two molecular clouds with separate velocities, V{sub LSR} = –14 km s{sup –1} and +5 km s{sup –1}. These clouds show rough spatial anti-correlation. Both clouds are associated with OH 1720 MHz emissions in the area overlapping with the Tornado Nebula. The spatial and velocity coincidence indicates violent interaction between the clouds and the Tornado Nebula. Modestly excited gas prefers the position of the Tornado 'head' in the –14 km s{sup –1} cloud, also suggesting the interaction. Virial analysis shows that the +5 km s{sup –1} cloud is more tightly bound by self-gravity than the –14 km s{sup –1} cloud. We propose a formation scenario for the Tornado Nebula; the +5 km s{sup –1} cloud collided into the –14 km s{sup –1} cloud, generating a high-density layer behind the shock front, which activates a putative compact object by Bondi-Hoyle-Lyttleton accretion to eject a pair of bipolar jets.

  8. Pre-Post Tornado Effects on Aggressive Children's Psychological and Behavioral Adjustment Through One-Year Postdisaster.

    Science.gov (United States)

    Lochman, John E; Vernberg, Eric; Powell, Nicole P; Boxmeyer, Caroline L; Jarrett, Matthew; McDonald, Kristina; Qu, Lixin; Hendrickson, Michelle; Kassing, Francesca

    2017-01-01

    Using a risk-resilience framework, this study examined how varying levels of exposure to a natural disaster (EF-4 tornado) and children's characteristics (sex; anxiety) influenced the behavioral and psychological adjustment of children who shared a common risk factor predisaster (elevated aggression) prior to exposure through 1-year postdisaster. Participants included 360 children in Grades 4-6 (65% male; 78% African American) and their parents from predominantly low-income households who were already participating in a longitudinal study of indicated prevention effects for externalizing outcomes when the tornado occurred in 2011. Fourth-grade children who were screened for overt aggressive behavior were recruited in 3 annual cohorts (120 per year, beginning in 2009). Parent-rated aggression and internalizing problems were assessed prior to the tornado (Wave 1), within a half-year after the tornado (Wave 2), and at a 1-year follow-up (Wave 3). Children and parents rated their exposure to aspects of tornado-related traumatic experiences at Wave 3. Children displayed less reduction on aggression and internalizing problems if the children had experienced distress after the tornado or fears for their life, in combination with their pre-tornado level of anxiety. Higher levels of children's and parents' exposure to the tornado interacted with children's lower baseline child anxiety to predict less reduction in aggression and internalizing problems 1 year after the tornado. Higher levels of disaster exposure negatively affected at-risk children's level of improvement in aggression and internalizing problems, when life threat (parent- and child-reported) and child-reported distress after the tornado were moderated by baseline anxiety.

  9. Meteorological and engineering approach to the regionalization of tornado wind criteria for nuclear power plant design

    International Nuclear Information System (INIS)

    1975-01-01

    Data on general meteorological factors governing tornado frequency and intensity in various locations throughout the USA are revised. A climatological model of multiple outbreak and long track tornadoes and the relation between the speed of a hurricane and the frequency of tornado occurrence over land and sea are discussed. Data from a structural engineering assessment of tornado damage are summarized and applications of the data for the development of design criteria for buildings and nuclear power plants to minimize tornado damage are suggested. It was concluded that it is very difficult to predict tornado risk and alternate methods and areas of study are presented for consideration

  10. Towards long pulse high performance discharges in Tore Supra: experimental knowledge and technological developments for heat exhaust

    International Nuclear Information System (INIS)

    1995-08-01

    This document deals with fusion heat exhaust experiments in Tore Supra tokamak. The purpose of the Tore Supra tokamak is to achieve and control long pulse powerful discharges. High input power is required to generate the non inductive current, approximately 25 MW . The conception and realisation of a Plasma Facing Component (PFC) scheme able to deal with this large amount of power is the main issue. A description of the water loop used for power removal and of the calorimetric system to determine the overall heat exhaust balance is provided. The infra-red measurements used during plasma operation are also described, together with several heat exhaust devices. The behaviour of ion cyclotron and lower hybrid wave launchers is addressed. Eventually, some information is provided on technological developments of PFC in Tore Supra. (TEC). 61 refs., 34 figs

  11. Tornadoes and Other Big Winds.

    Science.gov (United States)

    Markle, Sandra

    1983-01-01

    Information is presented for teaching about the formation of tornadoes and their effects. Ideas for relevant class discussion topics, writing assignments, and experiments to illustrate how temperature and air pressure changes involved in the storms work are also given. (PP)

  12. Supercell and tornado roles

    Science.gov (United States)

    as a consequence of the up- and down-motions. This also was considered a central idea by Lemon and herein. The definition of a tornado has been problematic (as discussed at some length here) but the basic definition of a vortex is problematic (Lugt 1979). The source of difficulty with defining a vortex is the

  13. Exploring the Experiences of Special Educators Following the Joplin Tornado

    Science.gov (United States)

    Palmer, Allyson

    2013-01-01

    On May 22, 2011, an EF5 tornado ripped through Joplin, MO, leaving many residents without homes and destroying or damaging several school buildings. The purpose of this qualitative study was to explore how special education teachers responded to the needs of their students with disabilities following the Joplin tornado. Purposeful sampling was…

  14. Controlled thermonuclear fusion: Tore Supra back bone of the EURATOM-CEA programme for the next ten years

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The decision to grant priority operation status to the French Tokamak Tore Supra will make it possible to start on the construction of this large machine and to bring together at the Cadarache Nuclear Study Centre all the facilities of the CEA for their research on fusion by magnetic confinement. The work is scheduled to begin in 1982 and to last until 1985. The financing is indicated and Tore Supra is briefly described [fr

  15. The Tore Supra Lower Hybrid Test Bed : improvements and applications

    International Nuclear Information System (INIS)

    Delpech, L.; Achard, J.; Beaumont, B.

    2006-01-01

    Within the CIMES project framework in Tore Supra, a klystron TH2103C (3.7 GHz) is under development at THALES ELECTRON DEVICES. It differs from the previous klystrons used in Tore Supra generator mainly in that it has no modulating anode, the RF output power will reach 700 kW CW, by raising the High Voltage value to 76 kV and a beam current up to 23 A. The Tore Supra test bed is a dedicated facility used for high power tests on RF components or on RF transmitters. It has been improved to integrate the TH2103C klystron and a specific 100 kV solide state switch which control the beam current. Since April 2005, the integration of the first tube (without modulating anode) and the 100 kV switch has been completed in the Test Bed and has allowed the modifications and tests of the interfaces and security system for the devices. Improvements were also made on the cooling loop flow to dissipate a power of 1750 kW CW. With these devices, the RF power routinely available in the Lower Hybrid Test Bed is 400 kW CW. With the development of the TH2103C, detailed studies and tests on RF components which will be used up to 750 kW CW on match load or 700 kW on VSWR = 1.4, are necessary to evaluate their performances and thermal behaviour. The test a crucial component, the recombiner, which adds the RF powers coming from the two RF outputs of the TH2103C and inject the resulted power into one WR284 waveguide to a test load or to the plasma, was completed. Two tests have been performed : a thermal study with 400 kW during 1000 s, and RF pulsed tests on short cuts to increase the value of the electric field inside the component. The experiments and calculations (ANSYS and HFSS codes) validate the use of this device with the TH2103C. A module made with two different Beryllium Oxide RF windows, has been under test. The losses on each window are measured by calorimetric measurements and evaluated by computation with HFSS and ANSYS code. The results are compared. In this paper, the

  16. Residential Tornado Safe Rooms from Commodity Wood Products: Wall Development and Impact Testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell; John C. Hermanson

    2015-01-01

    In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms and shelters have helped reduce the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a residential tornado safe room...

  17. Near-ground tornado-like vortex structure resolved by particle image velocimetry (PIV)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei [Iowa State University, Aerospace Engineering Department, Ames, IA (United States); University of Minnesota, Saint Anthony Falls Laboratory, Minneapolis, MN (United States); Sarkar, Partha P. [Iowa State University, Aerospace Engineering Department, Ames, IA (United States)

    2012-02-15

    The near-ground flow structure of tornadoes is of utmost interest because it determines how and to what extent civil structures could get damaged in tornado events. We simulated tornado-like vortex flow at the swirl ratios of S = 0.03-0.3 (vane angle {theta}{sub v} = 15 -60 ), using a laboratory tornado simulator and investigated the near-ground-vortex structure by particle imaging velocimetry. Complicated near-ground flow was measured in two orthogonal views: horizontal planes at various elevations (z = 11, 26 and 53 mm above the ground) and the meridian plane. We observed two distinct vortex structures: a single-celled vortex at the lowest swirl ratio (S = 0.03, {theta}{sub v} = 15 ) and multiple suction vortices rotating around the primary vortex (two-celled vortex) at higher swirl ratios (S = 0.1-0.3, {theta}{sub v} = 30 -60 ). We quantified the effects of vortex wandering on the mean flow and found that vortex wandering was important and should be taken into account in the low swirl ratio case. The tangential velocity, as the dominant velocity component, has the peak value about three times that of the maximum radial velocity regardless of the swirl ratio. The maximum velocity variance is about twice at the high swirl ratio ({theta}{sub v} = 45 ) that at the low swirl ratio ({theta}{sub v} = 15 ), which is contributed significantly by the multiple small-scale secondary vortices. Here, the results show that not only the intensified mean flow but greatly enhanced turbulence occurs near the surface in the tornado-like vortex flow. The intensified mean flow and enhanced turbulence at the ground level, correlated with the ground-vortex interaction, may cause dramatic damage of the civil structures in tornadoes. This work provides detailed characterization of the tornado-like vortex structure, which has not been fully revealed in previous field studies and laboratory simulations. It would be helpful in improving the understanding of the interaction between the

  18. Conceptions of Tornado Wind Speed and Land Surface Interactions among Undergraduate Students in Nebraska

    Science.gov (United States)

    Van Den Broeke, Matthew S.; Arthurs, Leilani

    2015-01-01

    To ascertain novice conceptions of tornado wind speed and the influence of surface characteristics on tornado occurrence, 613 undergraduate students enrolled in introductory science courses at a large state university in Nebraska were surveyed. Our findings show that students lack understanding of the fundamental concepts that (1) tornadoes are…

  19. TORE SUPRA 300 W - 1.75 K refrigerator report

    International Nuclear Information System (INIS)

    Gistau, G.M.; Bonneton, M.; Mart, J.W.

    1988-01-01

    The TORE SUPRA refrigerator is now installed and the acceptance tests have been completed. All equipment has performed above design levels. The liquid ring pumps and cold centrifugal compressors have run for more than 1000 hours. Commissioning and acceptance tests, including cooldown, variable heat load, unscheduled shutdown, power outage and automatic restart, and a 400-hour shakedown run, are described and evaluated

  20. Systematic Study of the Failure of a Light-Frame Wood Roof in a Tornado

    Directory of Open Access Journals (Sweden)

    Christine Standohar-Alfano

    2012-12-01

    Full Text Available Tornadoes are a particularly devastating natural hazard that affect communities across the United States, particularly the Midwest and South. They are unique from an engineering point-of-view due to their very low probability of occurrence but often highly destructive consequences. The 2011 season was particularly devastating to the Southeastern portion of the U.S. This paper presents a single case study of a 2012 tornado that struck a single large rural light-frame wood house with an unconventional roof system. A fragility methodology was used as a tool to probabilistically study the loss of the roof system, and bound an Enhanced Fujita (EF scale rating of the tornado. The tornado was initially rated as an EF3 tornado by the U.S. National Weather Service. However, following a detailed site inspection verified with numerical structural models, the tornado was downgraded to an EF2 tornado. As expected, the use of nail connections in a roof-to-wall connection resulted in a weaker link compared to a hurricane clip. The approach presented in this paper can be used as a supplement to the EF rating provided by U.S. National Weather Service meteorologists when unusual conditions in either the structure or surroundings exists.

  1. Tornado-like transport in a magnetized plasma

    Science.gov (United States)

    Poulos, Matthew; van Compernolle, Bart; Morales, George

    2017-10-01

    Recent heat transport experiments conducted in the LAPD device at UCLA in which avalanche events have been previously documented have also lead to the identification of a new tornado-like transport phenomenon. These tornados occur much earlier than the avalanches events, essentially in the interval following the application of the bias voltage that causes the injection of an electron beam from a ring-shaped LaB6 cathode into the afterglow of a cold, magnetized plasma. The tornados exhibit a low-frequency (4 kHz) (much lower than drift-waves), spiraling, global eigenmode whose transient behavior is responsible for significant radial transport well outside the heated region. Detailed experimental observations are compared with a Braginskii transport code that includes the effects of ExB convection induced by the spiraling global eigenmode. New insights are gained into the necessary modifications of classical transport to accurately simulate the spiraling effects and the possible interaction with avalanches. This work is supported by the NSF/DOE partnership in basic plasma science and engineering, Grant Number 1619505, and is performed at the Basic Plasma Science Facility, sponsored jointly by DOE and NSF. Sponsored by DOE/NSF at BaPSF and NSF 1619505.

  2. Community emergency department utilization following a natural disaster (the Goderich Tornado).

    Science.gov (United States)

    Appavoo, Samuel D; Khemlin, Alexander; Appavoo, Donna M; Flynn, Candi J

    2016-01-01

    On 21 August 2011 an F3 tornado hit the Canadian town of Goderich, Ontario, leaving 40 people injured and one dead. Specific medium-term changes in utilization of health care following a disaster have not been analyzed in medical literature. Documenting the emergency department utilization through this subacute period would be helpful to enable institutions and healthcare practitioners to be better prepared for future events. A medical chart review was conducted at the Alexandra Marine and General Hospital in Goderich. All emergency department visits made during the 30 days after the Tornado in 2011 (intervention group), 30 days prior to the tornado in 2011 (primary control group), and during the similar calendar period of 30 days after the tornado in 2010 (seasonal control group) were reviewed. Medical diagnoses of all patients who presented at the emergency department were collected and compared. Fewer people presented to the emergency department following the tornado than during the control periods, and those who did were significantly older than those who presented in the control periods (pptornado in a rural Ontario community. This information serves to inform the medical community and other hospitals how to increase their level of preparedness should a comparable disaster occur again in the future.

  3. Prominence and tornado dynamics observed with IRIS and THEMIS

    Science.gov (United States)

    Schmieder, Brigitte; Levens, Peter; Labrosse, Nicolas; Mein, Pierre; Lopez Ariste, Arturo; Zapior, Maciek

    2017-08-01

    Several prominences were observed during campaigns in September 2013 and July 2014 with the IRIS spectrometer and the vector magnetograph THEMIS (Tenerife). SDO/AIA and IRIS provided images and spectra of prominences and tornadoes corresponding to different physical conditions of the transition region between the cool plasma and the corona. The vector magnetic field was derived from THEMIS observations by using the He D3 depolarisation due to the magnetic field. The inversion code (PCA) takes into account the Hanle and Zeeman effects and allows us to compute the strength and the inclination of the magnetic field which is shown to be mostly horizontal in prominences as well as in tornadoes. Movies from SDO/AIA in 304 A and Hinode/SOT in Ca II show the highly dynamic nature of the fine structures. From spectra in Mg II and Si IV lines provided by IRIS and H-alpha observed by the Multi-channel Subtractive Double Pass (MSDP) spectrograph in the Meudon Solar Tower we derived the Doppler shifts of the fine structures and reconstructed the 3D structure of tornadoes. We conclude that the apparent rotation of AIA tornadoes is due to large-scale quasi-periodic oscillations of the plasma along more or less horizontal magnetic structures.

  4. Finite Element Analysis of Saferooms Subjected to Tornado Impact Loads

    Science.gov (United States)

    Parfilko, Y.; Amaral de Arruda, F.; Varela, B.

    2017-10-01

    A Tornado is one of the most dreadful and unpredictable events in nature. Unfortunately, weather and geographic conditions make a large portion of the United States prone to this phenomenon. Tornado saferooms are monolithic reinforced concrete protective structures engineered to guard against these natural disasters. Saferooms must withstand impacts and wind loads from EF-5 tornadoes - where the wind speed reaches up to 150 m/s (300 mph) and airborne projectiles can reach up to 50 m/s (100 mph). The objective of this work is to evaluate the performance of a saferoom under impact from tornado-generated debris and tornado-dragged vehicles. Numerical simulations were performed to model the impact problem using explicit dynamics and energy methods. Finite element models of the saferoom, windborne debris, and vehicle models were studied using the LS-DYNA software. RHT concrete material was used to model the saferoom and vehicle models from NCAC were used to characterize damage from impacts at various speeds. Simulation results indicate good performance of the saferoom structure at vehicle impact speeds up to 25 meters per second. Damage is more significant and increases nonlinearly starting at impact velocities of 35 m/s (78 mph). Results of this study give valuable insight into the dynamic response of saferooms subjected to projectile impacts, and provide design considerations for civilian protective structures. Further work is being done to validate the models with experimental measurements.

  5. Pellet injection and confinement in the tore supra tokamak

    International Nuclear Information System (INIS)

    Maget, P.

    1998-01-01

    Pellet injection in the centre of tokamak plasmas can lead to an improved confinement regime called PEP (Pellet Enhanced Performance). The present work is dedicated to the mechanisms involved in the PEP regimes obtained in the tokamak Tore Supra. A neoclassical approach of transport shows that it is the anomalous transport, due to plasma turbulence, that causes the enhanced confinement. A linear model describing electrostatic instabilities has been developed in order to study the roles of density profile and current profile during the PEP, in the limit of large growth rates. The effect of radial shear in flows is taken into account by removing the ExB shear flow rate from the linear growth rate, as suggested by non-linear numerical simulations of turbulence. A local transport coefficient is estimated from the knowledge of the linear growth rate and the mode width. We find that the peaked density profile in PEP regime lowers the diffusion coefficient, and that the velocity shear amplifies this effect. The evolution of the current profile is also stabilizing, but this parameter is not known with sufficient accuracy, so that its role in Tore Supra PEP experiments remains uncertain. (author)

  6. Characteristics of Tornado-Like Vortices Simulated in a Large-Scale Ward-Type Simulator

    Science.gov (United States)

    Tang, Zhuo; Feng, Changda; Wu, Liang; Zuo, Delong; James, Darryl L.

    2018-02-01

    Tornado-like vortices are simulated in a large-scale Ward-type simulator to further advance the understanding of such flows, and to facilitate future studies of tornado wind loading on structures. Measurements of the velocity fields near the simulator floor and the resulting floor surface pressures are interpreted to reveal the mean and fluctuating characteristics of the flow as well as the characteristics of the static-pressure deficit. We focus on the manner in which the swirl ratio and the radial Reynolds number affect these characteristics. The transition of the tornado-like flow from a single-celled vortex to a dual-celled vortex with increasing swirl ratio and the impact of this transition on the flow field and the surface-pressure deficit are closely examined. The mean characteristics of the surface-pressure deficit caused by tornado-like vortices simulated at a number of swirl ratios compare well with the corresponding characteristics recorded during full-scale tornadoes.

  7. One minute pulse operation in TORE SUPRA

    International Nuclear Information System (INIS)

    van Houtte, D.

    1992-01-01

    Long pulse operation is the main focus of the research program on the high field superconducting Tore Supra tokamak. During the past two years, most of subsystems (Lower Hybrid Current Drive, Ion Cyclotron Radiofrequency Heating, Pellet Injector, Inner Wall, Pump Limiters) have been tested separately and time constants of associated phenomena have been investigated. In 1992, combined experiments have allowed to perform a 1MA-1mn long flat top current plasma discharge. The present paper concentrates on the main characteristics of this long pulse high energy discharge

  8. Profile measurements of localized fast electrons and ions in TORE SUPRA

    International Nuclear Information System (INIS)

    Basiuk, V.; Roubin, J.P.; Becoulet, A.; Carrasco, J.; Martin, G.; Moreau, D.; Saoutic, B.

    1992-01-01

    The strong toroidal and poloidal anisotropy of the heat flux to the first wall of Tore Supra during additional heating has been related to suprathermal particle losses induced by the TF ripple. In this paper we describe a new system of electric collectors designed to diagnose these localized particles and we analyse measurements performed during LHCD, ICRH and NBI heating. The interaction of fast particles created by additional heating with the TF ripple perturbation in Tore Supra has been analyzed by a direct measurement of the localized particles. The good confinement region has been identified thanks to a peak in the measured current profiles and is in agreement with theory. During LHCD and ICRH, the global losses are weak but strongly anisotropic leading to hot spots at the wall. During ICRH, an ejection of fast ions by the sawteeth towards peripheral zones where they get lost in the ripple has been seen. This is a possible scenario of α particle losses in a reactor

  9. Management of water leaks on Tore Supra actively cooled fusion device

    International Nuclear Information System (INIS)

    Hatchressian, J.C.; Gargiulo, L.; Samaille, F.; Soler, B.

    2005-01-01

    Up to now, Tore Supra is the only fusion device fully equipped with actively cooled Plasma Facing Components (PFCs). In case of abnormal events during a plasma discharge, the PFCs could be submitted to a transient high power density (run away electrons) or to a continuous phenomena as local thermal flux induced by trapped suprathermal electrons or ions). It could lead to a degradation of the PFC integrity and in the worst case to a water leak occurrence. Such water leak has important consequence on the tokamak operation that concerns PFCs themselves, monitoring equipment located in the vacuum vessel or connected to the ports as RF antennas, diagnostics or pumping systems. Following successive water leak events (the most important water leak, that occurred in September 2002, is described in the paper), a large feedback experience has been gained on Tore supra since more than 15 years that could be useful to actively cooled next devices as W7X and ITER. (authors)

  10. Plasma Edge Control in Tore Supra

    International Nuclear Information System (INIS)

    Evans, T.E.; Mioduszewski, P.K.; Foster, C.; Haste, G.; Horton, L.; Grosman, A.; Ghendrih, P.; Chatelier, M.; Capes, H.; Michelis, C. De; Fall, T.; Geraud, A.; Grisolia, C.; Guilhem, D.; Hutter, T.

    1990-01-01

    TORE SUPRA is a large superconducting tokamak designed for sustaining long inductive pulses (t∼ 30 s). In particular, all the first wall components have been designed for steady-state heat and particle exhaust, particle injection, and additional heating. In addition to these technological assets, a strict control of the plasma-wall interactions is required. This has been done at low power: experiments with ohmic heating have been mainly devoted to the pump limiter, ergodic divertor and pellet injection experiments. Some specific problems arising in large tokamaks are encountered; the pump limiter and the ergodic divertor yield the expected effects on the plasma edge. The effects on the bulk are discussed

  11. Pump limiter studies in Tore Supra

    International Nuclear Information System (INIS)

    Chatelier, M.; Bonnel, P.; Bruneau, J.L.; Gil, C.; Grisolia, C.; Loarer, T.; Martin, G.; Pegourie, B.; Rodriguez, L.

    1991-01-01

    The aim of the Tore Supra pump limiter program is to study particle exhaust with a pump limiter system in long-pulse discharges with continuous pellet fueling and strong auxiliary heating. The pump limiter system consists of six vertical modules, located at the bottom of the machine, and one horizontal module at the outer midplane. The instrumentation of the limiter included pressure gauges, a residual gas analyser Langmuir probes, a spectrometer and water calorimeters. Initial results in low-density discharges, with the outboard limiter only, showed a modest effect on the plasma density, while large exhaust fluxes were measured in the pump limiter, without any external fueling

  12. Windfield and trajectory models for tornado-propelled objects. Final report

    International Nuclear Information System (INIS)

    Redmann, G.H.; Radbill, J.R.; Marte, J.E.; Dergarabedian, P.; Fendell, F.E.

    1983-03-01

    This is the final report of a three-phased research project to develop a six-degree-of-freedom mathematical model to predict the trajectories of tornado-propelled objects. The model is based on the meteorological, aerodynamic, and dynamic processes that govern the trajectories of missiles in a tornadic windfield. The aerodynamic coefficients for the postulated missiles were obtained from full-scale wind tunnel tests on a 12-inch pipe and car and from drop tests. Rocket sled tests were run whereby the 12-inch pipe and car were injected into a worst-case tornado windfield in order to verify the trajectory model. To simplify and facilitate the use of the trajectory model for design applications without having to run the computer program, this report gives the trajectory data for NRC-postulated missiles in tables based on given variables of initial conditions of injection and tornado windfield. Complete descriptions of the tornado windfield and trajectory models are presented. The trajectory model computer program is also included for those desiring to perform trajectory or sensitivity analyses beyond those included in the report or for those wishing to examine other missiles and use other variables

  13. Meteorological environment of a tornado outbreak in Southern Romania

    Directory of Open Access Journals (Sweden)

    I. C. Oprea

    2009-04-01

    Full Text Available On 7 May 2005, a squall line with an embedded bow echo formed over Southern Romania causing severe wind damage. The length of the wind damage was around 150 km. Three tornadoes have been reported, two of them being recorded by video camera. One of the tornadoes occurred in Buftea (near Bucharest, the second in Ciobanu village (near Medgidia radar site and the third in Movilita village, 40 km to the northeast of Bucharest. The site surveys confirmed wind damage associated with these tornadoes. Based on damage, the Movilita village tornado was classified as an F1 type on the Fujita scale, and the Buftea and Ciobanu village tornadoes were classified as F0. Large scale forcing was provided by a vigorous upper level trough. The squall line developed in the warm sector of a low, ahead of the cold front. The Bucharest EEC-DWSR-2500C Doppler velocity depicted cyclonically rotational structures associated with the left end of the bow echo. In two hours this squall line traversed the southern part of the country. The northern end of the line preserved the bowed structures and high reflectivity gradient in front of them. The dry air associated with the descending rear inflow jet was evident as rear inflow notches in the reflectivity field of the Bucharest C-band radar and the Medgidia S-band WSR-98 D radar. The synoptic and mesoscale environment associated with 7 May 2005 bow echo had many similarities to the "dynamic" pattern described by John and Hirt (1987. Herein are analyzed the combined effects of synoptic and mesoscale circulations, together with the data provided by C-band EEC-DWSR-2500C and S-band WSR-98D radars, and the ECMWF and ALADIN model output data. Some operational aspects of the warning process are also discussed.

  14. Number of warning information sources and decision making during tornadoes.

    Science.gov (United States)

    Luo, Jianjun; Cong, Zhen; Liang, Daan

    2015-03-01

    Taking proper protective action upon receiving tornado warnings is critical to reducing casualties. With more warning information sources becoming available, how the number of such information sources affects decision making should be quantitatively investigated. To examine how the number of warning information sources affected individuals' decisions to take protective action during tornadoes. A telephone survey using random sampling was conducted in 2012 with residents in Tuscaloosa AL and Joplin MO, resulting in a working sample of 782 respondents. Both cities were struck by violent tornadoes (Enhanced Fujita Scale [EF]4 and EF5) in 2011. The analysis was conducted in 2013. Logistic regression analysis showed that relative to having only one warning information source, having two and three or more warning information sources significantly increased the odds of taking protective action in Joplin but not in Tuscaloosa; having three or more sources had a significantly stronger effect on taking protective action in Joplin than in Tuscaloosa. Having an emergency preparation plan in both cities and being white in Tuscaloosa significantly increased the odds of taking protective action, whereas being divorced in Joplin reduced these odds. Receiving warnings from more warning information sources might be more beneficial in places with less previous exposure to tornadoes and for populations with lower awareness of a potential tornado and higher probability of receiving no warnings. Emergency management agencies and public health officials should give priority to these places and populations when formulating disaster mitigation decisions and policies. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Chaotic Financial Tornadoes

    Science.gov (United States)

    Jakimowicz, Aleksander

    In contemporary economies classic business cycles are increasingly changing their form undergoing a transformation into phenomena that have been nicknamed financial tornados. A generalization of the Lotka-Volterra model can be used to describe these fast-changing processes. Economically speaking, the most useful are such dynamical systems in which wormholes appear. This article features application of a model with one population of prey and two populations of predators in order to explain the global financial crisis and the consequent phenomena.

  16. Pre-Post Tornado Effects on Aggressive Children’s Psychological and Behavioral Adjustment Through One-Year Postdisaster

    Science.gov (United States)

    Lochman, John E.; Vernberg, Eric; Powell, Nicole P.; Boxmeyer, Caroline L.; Jarrett, Matthew; McDonald, Kristina; Qu, Lixin; Hendrickson, Michelle; Kassing, Francesca

    2017-01-01

    Objective Using a risk-resilience framework, this study examined how varying levels of exposure to a natural disaster (EF-4 tornado) and children’s characteristics (sex; anxiety) influenced the behavioral and psychological adjustment of children who shared a common risk factor predisaster (elevated aggression) prior to exposure through one-year postdisaster. Method Participants included 360 children in 4th–6th grades (65% male; 78% African American) and their parents from predominantly low-income households who were already participating in a longitudinal study of indicated prevention effects for externalizing outcomes when the tornado occurred in 2011. Fourth-grade children who were screened for overt aggressive behavior were recruited in three annual cohorts (120 per year, beginning in 2009). Parent-rated aggression and internalizing problems were assessed prior to the tornado (Wave 1), within a half-year after the tornado (Wave 2), and at a one-year follow-up (Wave 3). Children and parents rated their exposure to aspects of tornado-related traumatic experiences at Wave 3. Results Children displayed less reduction on aggression and internalizing problems if the children had experienced distress after the tornado or fears for their life, in combination with their pre-tornado level of anxiety. Higher levels of children’s and parents’ exposure to the tornado interacted with children’s lower baseline child anxiety to predict less reduction in aggression and internalizing problems one year after the tornado. Conclusion Higher levels of disaster exposure negatively affected at-risk children’s level of improvement in aggression and internalizing problems, when life threat (parent- and child-reported) and child-reported distress after the tornado were moderated by baseline anxiety. PMID:27841691

  17. Calibration procedures of the Tore-Supra infrared endoscopes

    Science.gov (United States)

    Desgranges, C.; Jouve, M.; Balorin, C.; Reichle, R.; Firdaouss, M.; Lipa, M.; Chantant, M.; Gardarein, J. L.; Saille, A.; Loarer, T.

    2018-01-01

    Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5 μm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.

  18. Conceptual design of a high heat flux toroidal pumped limiter for Tore Supra

    International Nuclear Information System (INIS)

    Doceul, L.; Schlosser, J.; Chappuis, Ph.; Chatelier, M.; Cocat, J.P.; Deck, C.; Faisse, F.; Grosman, A.; Mitteau, R.; Tonon, G.

    1994-01-01

    In the frame of the Tore-Supra upgrade, where it is planned to inject up to 25 MW during a time up to 1000 s, a complete toroidal pumped limiter covered of CFC (Carbon Fiber Composite) tiles is being designed. The design is based on the important experience gained from the operation on Tore Supra of actively cooled plasma facing components and pumped limiters. This toroidal limiter covers 7.5 m 2 of the bottom part of the inner vessel and is composed of 576 elementary components. Each element is built from dispersion strengthened copper (DSCu) protected by brazed CFC flat tiles and cooled by pressurised water at 150 deg C. This limiter is designed to sustain 15 MW of convective power. (author) 7 refs.; 5 figs., 3 tabs

  19. Development of a Probabilistic Tornado Wind Hazard Model for the Continental United States Volume I: Main Report

    International Nuclear Information System (INIS)

    Boissonnade, A; Hossain, Q; Kimball, J

    2000-01-01

    Since the mid-l980's, assessment of the wind and tornado risks at the Department of Energy (DOE) high and moderate hazard facilities has been based on the straight wind/tornado hazard curves given in UCRL-53526 (Coats, 1985). These curves were developed using a methodology that utilized a model, developed by McDonald, for severe winds at sub-tornado wind speeds and a separate model, developed by Fujita, for tornado wind speeds. For DOE sites not covered in UCRL-53526, wind and tornado hazard assessments are based on the criteria outlined in DOE-STD-1023-95 (DOE, 1996), utilizing the methodology in UCRL-53526; Subsequent to the publication of UCRL53526, in a study sponsored by the Nuclear Regulatory Commission (NRC), the Pacific Northwest Laboratory developed tornado wind hazard curves for the contiguous United States, NUREG/CR-4461 (Ramsdell, 1986). Because of the different modeling assumptions and underlying data used to develop the tornado wind information, the wind speeds at specified exceedance levels, at a given location, based on the methodology in UCRL-53526, are different than those based on the methodology in NUREG/CR-4461. In 1997, Lawrence Livermore National Laboratory (LLNL) was funded by the DOE to review the current methodologies for characterizing tornado wind hazards and to develop a state-of-the-art wind/tornado characterization methodology based on probabilistic hazard assessment techniques and current historical wind data. This report describes the process of developing the methodology and the database of relevant tornado information needed to implement the methodology. It also presents the tornado wind hazard curves obtained from the application of the method to DOE sites throughout the contiguous United States

  20. A Database of Tornado Events as Perceived by the USArray Transportable Array Network

    Science.gov (United States)

    Tytell, J. E.; Vernon, F.; Reyes, J. C.

    2015-12-01

    Over the course of the deployment of Earthscope's USArray Transportable Array (TA) network there have numerous tornado events that have occurred within the changing footprint of its network. The Array Network Facility based in San Diego, California, has compiled a database of these tornado events based on data provided by the NOAA Storm Prediction Center (SPC). The SPC data itself consists of parameters such as start-end point track data for each event, maximum EF intensities, and maximum track widths. Our database is Antelope driven and combines these data from the SPC with detailed station information from the TA network. We are now able to list all available TA stations during any specific tornado event date and also provide a single calculated "nearest" TA station per individual tornado event. We aim to provide this database as a starting resource for those with an interest in investigating tornado signatures within surface pressure and seismic response data. On a larger scale, the database may be of particular interest to the infrasound research community

  1. Experience gained from high heat flux actively cooled PFCs in Tore Supra

    International Nuclear Information System (INIS)

    Grosman, A.; Bayetti, P.; Brosset, C.; Bucalossi, J.; Cordier, J.J.; Durocher, A.; Escourbiac, F.; Ghendrih, Ph.; Guilhem, D.; Gunn, J.; Loarer, T.; Lipa, M.; Mitteau, R.; Pegourie, B.; Reichle, R.; Schlosser, J.; Tsitrone, E.; Vallet, J.C.

    2005-01-01

    The implementation of actively cooled high heat flux plasma facing components (PFCs) is one of the major ingredients required for operating the Tore Supra tokamak with very long pulses. A pioneering activity has been developed in this field from the very beginning of the device operation that is today culminating with the routine operation of an actively cooled toroidal pumped limiter (TPL) capable to sustain up to 10 MW/m 2 of nominal convected heat flux. Technical information is drawn from the whole development up to the industrialisation and focuses on a number of critical issues, such as bonding technology analysis, manufacture processes, repair processes, destructive and non-destructive testing. The actual experience in Tore Supra allows to address the question of D retention on carbon walls. Redeposition on surfaces without plasma flux is suspected to cause the final 'burial' of about half of the injected gas during long discharges

  2. Plasma-liquid system with reverse vortex flow of 'tornado' type (TORNADO-LE)

    International Nuclear Information System (INIS)

    Nedybalyuk, O.A.; Chernyak, V.Ya.; Olszewski, S.V.

    2010-01-01

    The results of experimental investigations of the plasma in plasma-liquid system with reverse vortex flow of 'tornado' type are presented. Volt-ampere characteristic of discharge in the current range from 200 to 400 mA were measured. Emission spectra of plasma in range from 200 to 1100 nm were measured. Excitation temperatures (electronic T e * , vibrational T v * and rotational T r * ) were obtained. Emission spectra of hydroxyl OH were calculated.

  3. Lower-hybrid wave coupling and impurity generation in Tore Supra

    International Nuclear Information System (INIS)

    Goniche, M.; Litaudon, X.; Guilhem, D.; Hutter, T.; Beaumont, B.; Froissart, P.; Rey, G.; Saoutic, B.

    1995-01-01

    This document deals with the high power coupling of Lower Hybrid (LH) waves in Tore Supra. The effect of the plasma shape is described, together with LH coupling in ion-cyclotron resonance experiments. It appears that plasma modifications can alter the LH coupling. Eventually, the effect of LH power on thermal load and impurity generation is presented. (TEC). 3 refs., 3 figs

  4. Practitioners' Experiences Creating and Implementing an Emotional Recovery and Physical Activity Program Following a Natural Disaster

    Science.gov (United States)

    Wahl-Alexander, Zachary

    2015-01-01

    On April 27, 2011 a series of tornadoes tore through the southeast United States. Sixty-four percent of the counties in the state of Alabama were directly affected by these storms. After a natural disaster, children who are directly or indirectly affected show numerous intense emotional reactions. Recovery programs can be set up to enable them to…

  5. Keeping Students Safe: Introducing the Monolithic Dome

    Science.gov (United States)

    Lanham, Carol

    2009-01-01

    The tiny town of Niangua, Missouri, made national headlines in 2008 when a rare cluster of winter tornadoes tore across the state on an unseasonably warm January night. The twisters killed a Niangua woman in her trailer home and destroyed numerous other structures. News photos of the trailer debris were a sobering reminder of the vulnerability of…

  6. First plasma experiments in Tore Supra with a new generation of high heat flux limiters for RF antennas

    International Nuclear Information System (INIS)

    Agarici, G.; Beaumont, B.; Bibet, Ph.; Bremond, S.; Bucalossi, J.; Colas, L.; Durocher, A.; Gargiulo, L.; Ladurelle, L.; Lombard, G.; Martin, G.; Mollard, P.

    2000-01-01

    During the 1997 and 1998 Tore Supra shutdown, a first set of new antenna guard limiters was installed on one of the three ion cyclotron resonance heating (ICRH) antennas of Tore Supra. This limiter, which was one of the main technological studies of the 1998 campaign, was widely experimented in real plasma conditions, thus allowing the validation in situ, for the first time, of the technology of active metal casting (AMC) for plasma facing components. The huge improvement in the thermal response of the new limiter generation, compared to the old one, is shown on plasma pulses made identical in terms of antenna position and injected RF power profile. By using the infrared cameras installed inside Tore Supra and viewing the antennas front, the power density fluxes received by the carbon fibre composite (CFC) surface of the limiter were evaluated by correlation with the heat load tests made on the electrons beam facility of CEA/Framatome

  7. Deuterium Inventory in Tore Supra (DITS): 2nd post-mortem analysis campaign and fuel retention in the gaps

    International Nuclear Information System (INIS)

    Dittmar, T.; Tsitrone, E.; Pegourie, B.; Cadez, I.; Pelicon, P.; Gauthier, E.; Languille, P.; Likonen, J.; Litnovsky, A.; Markelj, S.; Martin, C.; Mayer, M.; Pascal, J.-Y.; Pardanaud, C.; Philipps, V.; Roth, J.; Roubin, P.; Vavpetic, P.

    2011-01-01

    A dedicated study on fuel retention has been launched in Tore Supra, which includes a D wall-loading campaign and the dismantling of the main limiter (Deuterium Inventory in Tore Supra, DITS project). This paper presents new results from a second post-mortem analysis campaign on 40 tiles with special emphasis on the D retention in the gaps. SIMS analysis reveals that only 1/3 of the thickness of deposits in the plasma shadowed zones are due to the DITS wall-loading campaign. As pre-DITS deposits contain less D than DITS deposits, the contribution of DITS to the D inventory is about 30-50%. The new estimate for the total amount of D retained in the Tore Supra limiter is 1.7 x 10 24 atoms, close to the previous estimate, with the gap surfaces contributing about 33%. NRA measurements show a stepped decrease of D along the gap with strong asymmetries between different gap orientations.

  8. Condensation-induced kinematics and dynamics of cyclones, hurricanes and tornadoes

    International Nuclear Information System (INIS)

    Makarieva, A.M.; Gorshkov, V.G.

    2009-01-01

    A universal equation is obtained for air pressure and wind velocity in cyclones, hurricanes and tornadoes as dependent on the distance from the center of the considered wind pattern driven by water vapor condensation. The obtained theoretical estimates of the horizontal profiles of air pressure and wind velocity, eye and wind wall radius in hurricanes and tornadoes and maximum values of the radial, tangential and vertical velocity components are in good agreement with empirical evidence.

  9. Solar Tornado Prominences: Plasma Motions Along Filament Barbs

    Science.gov (United States)

    Panasenco, Olga; Velli, Marco; Martin, Sara F.; Rappazzo, Franco

    2013-03-01

    Recent high-resolution observations from the Solar Dynamic Observatory (SDO) have reawakened interest in the old and fascinating phenomenon of solar tornado prominences. This class of prominences was first introduced by E. Pettit in 1932, who studied them over many years up to 1950. High resolution and high cadence multi-wavelength data obtained by SDO reveal that the tornado-like properties of these prominences are mainly an illusion due to projection effects. We show that counterstreaming plasma motions with projected velocities up to +/- 45 km/sec along the prominence spine and barbs create a tornado-like impression when viewed at the limb. We demonstrate that barbs are often rooted at the intersection between 4-5 supergranular cells. We discuss the observed oscillations along the vertical parts of barbs and whether they may be related to vortex flows coming from the convection downdrafts at the intersection of supergranules (and possibly smaller convective cells) in the photosphere and their entrained magnetic field. The unwinding of magnetic threads near the photosphere via reconnection might be a source of the waves which are observed as oscillations in prominence barbs.

  10. Net erosion measurements on plasma facing components of Tore Supra

    International Nuclear Information System (INIS)

    Tsitrone, E.; Chappuis, P.; Corre, Y.; Gauthier, E.; Grosman, A.; Pascal, J.Y.

    2001-01-01

    Erosion of the plasma facing components is a crucial point of investigation in long pulse operation of future fusion devices. Therefore erosion measurements have been undertaken in the Tore Supra tokamak. After each experimental campaign, different plasma facing components have been monitored in situ by non-destructive means, in order to evaluate their net erosion following a long plasma exposure. This paper presents the results obtained over three experimental campaigns on the Tore Supra ergodic divertor B 4 C-coated neutralisers and CFC Langmuir probes. The erosion on the Langmuir probes after one year of plasma exposure can reach 100 μm, leading to an effective erosion coefficient of around 5x10 -3 to 10 -2 , in reasonable agreement with values found on other tokamaks. The erosion of the ergodic divertor neutraliser plates is lower (10 μm). This is coherent with the attenuated particle flux due to a lower incidence angle, and might also be due to some surface temperature effect, since the neutralisers are actively cooled while the Langmuir probes are not. Moreover, the profile along the neutraliser shows net erosion in zones wetted by the plasma and net redeposition in shadowed zones

  11. Climatology, storm morphologies, and environments of tornadoes in the British Isles: 1980–2012

    OpenAIRE

    Mulder, Kelsey J.; Schultz, David M.

    2015-01-01

    A climatology is developed for tornadoes during 1980–2012 in the British Isles, defined in this article as England, Scotland, Wales, Northern Ireland, Republic of Ireland, Channel Islands, and the Isle of Man. The climatology includes parent storm type, interannual variability, annual and diurnal cycles, intensities, oc- currence of outbreaks (defined as three or more tornadoes in the same day), geographic distribution, and environmental conditions derived from proximity soundings of tornadoe...

  12. Operation of an ITER relevant inspection robot on Tore Supra tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Gargiulo, Laurent [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)], E-mail: laurent.gargiulo@cea.fr; Bayetti, Pascal; Bruno, Vincent; Hatchressian, Jean-Claude; Hernandez, Caroline; Houry, Michael [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Keller, Delphine [CEA, LIST, Service de Robotique Interactive, F-92265 Fontenay aux Roses (France); Martins, Jean-Pierre [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Measson, Yvan; Perrot, Yann [CEA, LIST, Service de Robotique Interactive, F-92265 Fontenay aux Roses (France); Samaille, Frank [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2009-06-15

    Robotic operations are one of the major maintenance challenges for ITER and future fusion reactors. CEA has developed a multipurpose carrier able to realize deployments in the plasma vessel without breaking the Ultra High Vacuum (UHV) and temperature conditioning. A 6 years R and D programme was jointly conducted by CEA-LIST Interactive Robotics Unit and the Institute for Magnetic Fusion Research (IRFM) in order to demonstrate the feasibility and reliability of an in-vessel inspection robot relevant to ITER requirements. The Articulated Inspection Arm robot (AIA) is an 8-m long multilink carrier with a payload up to 10 kg operable between plasma under tokamak conditioning environment; its geometry allows a complete close inspection of Plasma Facing Components (PFCs) of the Tore Supra vessel. Different tools are being developed by CEA to be plugged at the front head of the carrier. The diagnostic presently in operation consists in a viewing system offering accurate visual inspection of PFCs. Leak detection of first wall based on helium sniffing and laser compact system for carbon co-deposited layers characterizations or treatments are also considered for demonstration. In April 2008, the AIA robot equipped with its vision diagnostic has realized a complete deployment into Tore Supra and the first closed inspection of the vessel under UHV conditions. During the upcoming experimental campaign, the same operation will be performed under relevant conditions (10{sup -6} Pa and 120 deg. C) after a conditioning phase at 200 deg. C to avoid outgassing pollution of the chamber. This paper describes the different steps of the project development, robot capabilities with the present operations conducted on Tore Supra and future requirements for making the robot a tool for tokamak routine operation.

  13. Daily variation in natural disaster casualties: information flows, safety, and opportunity costs in tornado versus hurricane strikes.

    Science.gov (United States)

    Zahran, Sammy; Tavani, Daniele; Weiler, Stephan

    2013-07-01

    Casualties from natural disasters may depend on the day of the week they strike. With data from the Spatial Hazard Events and Losses Database for the United States (SHELDUS), daily variation in hurricane and tornado casualties from 5,043 tornado and 2,455 hurricane time/place events is analyzed. Hurricane forecasts provide at-risk populations with considerable lead time. Such lead time allows strategic behavior in choosing protective measures under hurricane threat; opportunity costs in terms of lost income are higher during weekdays than during weekends. On the other hand, the lead time provided by tornadoes is near zero; hence tornados generate no opportunity costs. Tornado casualties are related to risk information flows, which are higher during workdays than during leisure periods, and are related to sheltering-in-place opportunities, which are better in permanent buildings like businesses and schools. Consistent with theoretical expectations, random effects negative binomial regression results indicate that tornado events occurring on the workdays of Monday through Thursday are significantly less lethal than tornados that occur on weekends. In direct contrast, and also consistent with theory, the expected count of hurricane casualties increases significantly with weekday occurrences. The policy implications of observed daily variation in tornado and hurricane events are considered. © 2012 Society for Risk Analysis.

  14. Edge density profile measurements by X-mode reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Bottereau, C.; Chareau, J.M.; Paume, M.; Sabot, R.

    2000-10-01

    A broadband reflectometer operating in the frequency range 50-75 GHz has been developed on Tore Supra to measure electron density profiles at the edge. The system uses extraordinary mode polarization and performs routine measurements in 20 μs with a heterodyne detection to ensure a high dynamic range sensitivity. It allows separate phase and amplitude information of the signal. The density profiles are fully automatically calculated from the raw phase. The initialization is done with an automatic detection of the first cut-off from the amplitude of the reflected signal with accuracy up to ±0.5 cm. The profiles are now part of the public database of Tore Supra (TS) and can provide details of density structures better than the centimeter range. High reliability of the measurements for various plasma conditions make this diagnostic an ideal tool to study specific edge plasma physics with given examples on detached plasma behaviour and RF antenna-plasma coupling processes. It also is shown how the presence of suprathermal electrons may perturb the measurements. (authors)

  15. Integration of advanced feedback control techniques on Tore Supra

    International Nuclear Information System (INIS)

    Barana, O.; Basiuk, V.; Bucalossi, J.

    2006-01-01

    Tore Supra tokamak plays an important role in development and optimisation of steady-state scenarios. Its real-time feedback control system is a key instrument to improve plasma performances. For this reason, new feedback control schemes have been recently put into operation and others are being developed. This work deals with the implementation in Tore Supra of these advanced algorithms, reports the technical details and shows the first positive results that have been achieved. For instance, encouraging results have been obtained in the field of profiles control. Controls of the full width at half maximum of the suprathermal electrons local emission profile at very low loop voltage and of the maximum of the thermal Larmor radius, normalised to the characteristic length of the electron temperature gradient, have been attained. While the first quantity can be directly associated to the current profile, the second one characterises the pressure profile. A new feedback control algorithm, employed to maximise a given quantity by means of a '' Search Optimisation '' technique, has been effectively tested too: the hard X-ray width has been maximised with simultaneous use of lower hybrid heating power and wave parallel index as actuators. These and other promising results, whose detailed description will be given in the article, have been obtained thanks to the real-time availability of several diagnostic systems. Using a shared memory network as communication layer, they send their measurements to a central computing unit that, in its turn, dispatches the necessary requirements to the actuators. A key issue is the possibility to integrate these controls in such a way as to cope with different requests at the same time. As an example, simultaneous control of the plasma current by means of the lower hybrid heating power, of the loop voltage by means of the poloidal field system and of the hard X-ray width through the lower hybrid heating phase shift has been successfully

  16. Problems and proposed solution in evaluating tornado-borne missile speed

    International Nuclear Information System (INIS)

    Eguchi, Yuzuru; Sugimoto, Soichiro; Hattori, Yasuo; Hirakuchi, Hiromaru

    2014-01-01

    Large variation was found among the design values of tornado missile speed shown in current standards and guides in Japan and U.S. It was also found that the design missile speed indicated in the Guide issued by the Nuclear Regulation Authority of Japan is the most restrictive among them. The primary reason is due to the evaluation method where all the objects are unconditionally assumed to be placed in air as high as 40 m, even if the object should be on the ground. In order to solve this problem, the authors have adopted the tornado engineering model DBT-77 proposed by Dr. Fujita as a wind field model, and developed a numerical analysis code TONBOS with adding an object liftoff model. The effectiveness of the numerical analysis code was demonstrated by simulating liftoff and flight of a truck struck by an F3 tornado in Saroma. (author)

  17. Evaluation of atmospheric-pressure change in tornado using Fujita model

    International Nuclear Information System (INIS)

    Shimizu, Juntaro; Ohtsubo, Shunsuke

    2017-01-01

    Evaluation of the atmospheric-pressure change (APC) in a tornado is necessary to assess the integrity of nuclear-related facilities. The Rankine model has been most frequently used to theoretically calculate the APC in a tornado. The result, however, is considered to be overly conservative because the Rankine model wind speed at the ground is larger than that in reality. On the other hand, the wind speed of the Fujita model is closer to that of actual tornadoes but is expressed by more complicated algebraic equations than that in the Rankine model. Also, because it is impossible to analytically derive the APC equation using the Fujita model, numerical computation is required. A previous study employed the finite element method (FEM) for such a purpose. However, a general-purpose FEM code often requires complicated input parameters. In order to conduct parametric studies to evaluate the integrity of facilities in various cases of tornadoes, the finite-difference method code “TORPEC”, which is specialized to analyze the APC, was developed as a convenient design tool. TORPEC is based on Poisson’s equation derived from the Navier-Stokes equation. It also runs on widely available technical calculation software such as Microsoft"® Excel VBA or MATLAB"®. Taking advantage of such convenience, various calculations have been conducted to reveal the characteristics of APC as functions of the maximum tangential wind speed, axial position and tornado radius. TORPEC is used as a benchmark in the existing paper. The case study results obtained by TORPEC show a constant ratio of the pressure drop of the Fujita model against the Rankine model. This factor can be used to derive the Fujita model result from the Rankine model result without FEM analysis. (author)

  18. Radio frequency additional heating systems issues for the TORE-SUPRA WEST project

    NARCIS (Netherlands)

    Guilhem, D.; Argouarch, A.; Bernard, J.M.; Bouquey, F.; Colas, L.; Delpech, L.; Durodié, F.; Ekedahl, A.; Helvoirt, J.; Hillairet, J.; Joffrin, E.; Litaudon, X.; Magne, R.; Milanesio, D.; Moerel, J.; Mollard, P.; Wittebol, E.; Achard, J.; Armitano, A.; Berger-By, G.; Charabot, N.; Goniche, M.; Jacquot, J.; Lombard, G.; Prou, M.; Traisnel-Corbel, E.; Volpe, R.; Vulliez, K.

    2013-01-01

    This year TORE-SUPRA celebrated its 25 years of operation. During this long time a number of technologies have been developed [1]. First of all it was mandatory to develop reliable superconducting magnets at ∼ - 4 K, with superfluid helium as efficient coolant. For the production of steady state

  19. Near infrared thermography by CCD cameras and application to first wall components of Tore Supra tokamak; Thermographie proche infrarouge par cameras CCD et application aux composants de premiere paroi du tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, F.

    1996-06-07

    In the Tokamak TORE-SUPRA, the plasma facing components absorbs and evacuate (active cooling) high power fluxes (up to 10 MW/m{sup 2}). Their thermal behavior study is essential for the success of controlled thermonuclear fusion line. The first part is devoted to the study of power deposition on the TORE-SUPRA actively cooled limiters. A model of power deposition on one of the limiters is developed. It takes into account the magnetic topology and a description of the plasma edge. The model is validated with experimental calorimetric data obtained during a series of shots. This will allow to compare the surface temperature measurements with the predicted ones. The main purpose of this thesis was to evaluate and develop a new temperature measurement system. It works in the near infrared range (890 nm) and is designed to complete the existing thermographic diagnostic of TORE-SUPRA. By using the radiation laws (for a blackbody and the plasma) and the laboratory calibration one can estimate the surface temperature of the observed object. We evaluate the performances and limits of such a device in the harsh conditions encountered in a Tokamak environment. On the one hand, in a quasi ideal situation, this analysis shows that the range of measurements is 600 deg. C to 2500 deg. C. On the other hand, when one takes into account of the plasma radiation (with an averaged central plasma density of 6.10{sup 19} m{sup -3}), we find that the minimum surface temperature rise to 900 deg. C instead of 700 deg. C. In the near future, according to the development of IR-CCD cameras working in the near infrared range up to 2 micrometers, we will be able to keep the good spatial resolution with an improved lower limit for the temperature down to 150 deg. C. The last section deals with a number of computer tools to process the images obtained from experiments on TORE-SUPRA. A pattern recognition application was developed to detect a complex plasma iso-intensity structure. 87 refs.

  20. Eddy current calculations for the tore supra tokamak

    International Nuclear Information System (INIS)

    Blum, J.; Dupas, L.; Leloup, C.; Thooris, B.

    1983-01-01

    This paper deals with the calculation of the eddy currents in the structures of a Tokamak, which can be assimilated to thin conductors, so that the three-dimensional problem can be reduced mathematically to a two-dimensional one, the variables being two orthogonal coordinates of the considered surface. A variational formulation of the problem in terms of the electric vector potential is then given and a finite element method has been used, which enables to treat the complicated geometry of the toroidal field magnet, the mechanical structures and the vacuum vessels of Tore Supra

  1. A new protection system against high voltage vacuum breakdowns developed for the Tore Supra neutral beam injector prototype

    International Nuclear Information System (INIS)

    Fumelli, M.; Jequier, F.; Pamela, J.

    1988-01-01

    A passive protection system against high voltage vacuum breakdowns has been developed. This system is based on the principle of oscillatory discharges in an RLC circuit coupled with the use of a diode. It allows the interruption of a vacuum breakdown in a few milliseconds. This study has been made for protecting some parts of the neutral beam injectors of the Tore Supra Tokamak experiment, but its field of application should be quite large. The conception of the whole high voltage electrical circuit developed for the Tore Supra injector prototype experiments is also presented

  2. Note: Measurements of fast electrons in the TORE-SUPRA tokamak by means of modified Cherenkov-type diamond detector

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Jakubowski, M. J.; Malinowski, K.; Mirowski, R. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland); Lotte, Ph.; Goniche, M.; Gunn, J.; Colledani, G.; Pascal, J.-Y.; Basiuk, V. [CEA, IRFM, F-13108 Saint Paul-lez-Durance (France)

    2013-01-15

    The Note reports on experimental studies of ripple born fast electrons within the TORE-SUPRA facility, which were performed by means of a modified measuring head equipped with diamond detectors designed especially for recording the electron-induced Cherenkov radiation. There are presented signals produced by fast electrons in the TORE-SUPRA machine, which were recorded during two experimental campaigns performed in 2010. Shapes of these electron-induced signals are considerably different from those observed during the first measurements carried out by the prototype Cherenkov probe in 2008. An explanation of the observed differences is given.

  3. Note: Measurements of fast electrons in the TORE-SUPRA tokamak by means of modified Cherenkov-type diamond detector

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M. J.; Zebrowski, J.; Rabinski, M.; Jakubowski, M. J.; Malinowski, K.; Mirowski, R.; Lotte, Ph.; Goniche, M.; Gunn, J.; Colledani, G.; Pascal, J.-Y.; Basiuk, V.

    2013-01-01

    The Note reports on experimental studies of ripple born fast electrons within the TORE-SUPRA facility, which were performed by means of a modified measuring head equipped with diamond detectors designed especially for recording the electron-induced Cherenkov radiation. There are presented signals produced by fast electrons in the TORE-SUPRA machine, which were recorded during two experimental campaigns performed in 2010. Shapes of these electron-induced signals are considerably different from those observed during the first measurements carried out by the prototype Cherenkov probe in 2008. An explanation of the observed differences is given.

  4. Explicating Experience: Development of a Valid Scale of Past Hazard Experience for Tornadoes.

    Science.gov (United States)

    Demuth, Julie L

    2018-03-23

    People's past experiences with a hazard theoretically influence how they approach future risks. Yet, past hazard experience has been conceptualized and measured in wide-ranging, often simplistic, ways, resulting in mixed findings about its relationship with risk perception. This study develops a scale of past hazard experiences, in the context of tornadoes, that is content and construct valid. A conceptual definition was developed, a set of items were created to measure one's most memorable and multiple tornado experiences, and the measures were evaluated through two surveys of the public who reside in tornado-prone areas. Four dimensions emerged of people's most memorable experience, reflecting their awareness of the tornado risk that day, their personalization of the risk, the intrusive impacts on them personally, and impacts experienced vicariously through others. Two dimensions emerged of people's multiple experiences, reflecting common types of communication received and negative emotional responses. These six dimensions are novel in that they capture people's experience across the timeline of a hazard as well as intangible experiences that are both direct and indirect. The six tornado experience dimensions were correlated with tornado risk perceptions measured as cognitive-affective and as perceived probability of consequences. The varied experience-risk perception results suggest that it is important to understand the nuances of these concepts and their relationships. This study provides a foundation for future work to continue explicating past hazard experience, across different risk contexts, and for understanding its effect on risk assessment and responses. © 2018 Society for Risk Analysis.

  5. Axisymmetric Tornado Simulations with a Semi-Slip Boundary

    Directory of Open Access Journals (Sweden)

    Brian H. Fiedler

    2017-12-01

    Full Text Available The structure of natural tornadoes and simulated analogs are sensitive to the lower boundary condition for friction. Three-dimensional numerical simulations of storms require a choice for turbulence parameterizations and resolution of wind near the lower boundary. This article explores some of the consequences of choices of a surface drag coefficient on the structure of a mature simulated tornado, using a conventional axisymmetric model. The surface drag parameterization is explored over the range of the semi-slip condition, including the extremes of no-slip and free-slip. A moderate semi-slip condition allows for an extreme pressure deficit, but without the unrealistic vortex breakdown of the no-slip condition.

  6. On necessity of revaluation of nuclear power safety of Ukraine in the tornado hazardous areas

    International Nuclear Information System (INIS)

    Skalozubov, V.I.; Gablaya, T.V.; Vasilchenko, S.V.; Kozlov, I.V.

    2015-01-01

    The article contains the main provisions regulating the tornado danger of objects of atomic energy, as well as analysis of the known results of evaluations of the impact of hurricanes on the safety of nuclear power plants of Ukraine, received in the ''before'' and ''post Fukushima'' periods. As a result of analysis is insufficient justification to the estimated frequency of passing tornadoes and exclusion from consideration emergency events with flooding of indus-trial sites under the influence of tornadoes not less than 2-th class intensity, defined a reassessment of NPP safety of Ukraine taking into account reasonably established performance tornado dangerous areas and lessons Fukushima accident

  7. Casualty Risk From Tornadoes in the United States is Highest in Urbanized Areas Across the Mid South

    Science.gov (United States)

    Fricker, T.; Elsner, J.

    2017-12-01

    Risk factors for tornado casualties are well known. Less understood is how and to what degree these determinants, after controlling for strength and urban density, vary spatially and temporally. Here we fit models to casualty counts from all casualty-producing tornadoes since 1995 in order to quantify the interactions between urbanization and energy on casualty rates. Results from the models show that the more urbanized areas of the Mid South are substantively and significantly more vulnerable to casualties from tornadoes than elsewhere in the country. Casualty rates are significantly higher on the weekend for tornadoes in this region. Night and day casualty rates are similar regardless of where they occur. Higher vulnerability to casualties from tornadoes occurring in more urbanized areas correspond significantly with greater percentages of elderly people. Many of the micro cities in the Mid South are threatened by tornadoes annually and this threat might potentially be exacerbated by climate change.

  8. Cybele: a large size ion source of module construction for Tore-Supra injector

    International Nuclear Information System (INIS)

    Simonin, A.; Garibaldi, P.

    2005-01-01

    A 70 keV 40 A hydrogen beam injector has been developed at Cadarache for plasma diagnostic purpose (MSE diagnostic and Charge exchange) on the Tore-Supra Tokamak. This injector daily operates with a large size ions source (called Pagoda) which does not completely fulfill all the requirements necessary for the present experiment. As a consequence, the development of a new ion source (called Cybele) has been underway whose objective is to meet high proton rate (>80%), current density of 160 mA/cm 2 within 5% of uniformity on the whole extraction surface for long shot operation (from 1 to 100 s). Moreover, the main particularity of Cybele is the module construction concept: it is composed of five source modules vertically juxtaposed, with a special orientation which fits the curved extraction surface of the injector; this curvature ensures a geometrical focalization of the neutral beam 7 m downstream in the Tore-Supra chamber. Cybele will be tested first in positive ion production for the Tore-Supra injector, and afterward in negative ion production mode; its modular concept could be advantageous to ensure plasma uniformity on the large extraction surface (about 1 m 2 ) of the ITER neutral beam injector. A module prototype (called the Drift Source) has already been developed in the past and optimized in the laboratory both for positive and negative ion production, where it has met the ITER ion source requirements in terms of D-current density (200 A/m 2 ), source pressure (0.3 Pa), uniformity and arc efficiency (0.015 A D-/kW). (authors)

  9. Development of a tornado wind speed hazard model for limited area (TOWLA) for nuclear power plants at a coastline

    International Nuclear Information System (INIS)

    Hirakuchi, Hiromaru; Nohara, Daisuke; Sugimoto, Soichiro; Eguchi, Yuzuru; Hattori, Yasuo

    2016-01-01

    It is necessary for Japanese electric power companies to assess tornado risks on the nuclear power plants according to a new regulation in 2013. The new regulatory guide recommends to select a long narrow strip area along a coast line with the width of 5 km to the seaward and landward sides as a target area of tornado risk assessment, because most of Japanese tornados have been reported near the coast line, where all of Japanese nuclear power plants are located. However, it is very difficult to evaluate a tornado hazard along a coast line, because there is no available information of F-scale and damage length/width on tornadic waterspouts. The purpose of this study is to propose a new tornado wind hazard model for limited area (TOWLA), which can be apply to a long narrow strip area along a coastline. In order to consider tornadic waterspouts moved inland, we evaluate the number of waterspouts entering/passing the targeting area, and add them to the total number of the tornado occurred in the area. A characteristic of the model is to use 'segment lengths' instead of damage lengths. The segment length is a part of the tornado foot print in the long narrow strip area. We show two methods for segment length computation. One is based on tornado records; latitude and longitude of tornado genesis and dissipation locations. The other is to compute the expected segment length based on the geometrical relationship among the damage length, area width, and directional characteristics of tornado movement. The new model can also consider the variation of tornado intensity along the path length and across the path width. (author)

  10. Infrared surface temperature measurements for long pulse operation, and real time feedback control in Tore-Supra, an actively cooled Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Guilhem, D.; Adjeroud, B.; Balorin, C.; Buravand, Y.; Bertrand, B.; Bondil, J.L.; Desgranges, C.; Gauthier, E.; Lipa, M.; Messina, P.; Missirlian, M.; Mitteau, R.; Moulin, D.; Pocheau, C.; Portafaix, C.; Reichle, R.; Roche, H.; Saille, A.; Vallet, S

    2004-07-01

    Tore-Supra has a steady-state magnetic field using super-conducting magnets and water-cooled plasma facing components for high performances long pulse plasma discharges. When not actively cooled, plasma-facing components can only accumulate a limited amount of energy since the temperature increase continuously (T proportional to {radical}(t)) during the discharge until radiation cooling is equal to the incoming heat flux (T > 1800 K). Such an environment is found in most today Tokamaks. In the present paper we report the recent results of Tore-Supra, especially the design of the new generation of infrared endoscopes to measure the surface temperature of the plasma facing components. The Tore-Supra infrared thermography system is composed of 7 infrared endoscopes, this system is described in details in the paper, the new JET infrared thermography system is presented and some insights of the ITER set of visible/infrared endoscope is given. (authors)

  11. Infrared surface temperature measurements for long pulse operation, and real time feedback control in Tore-Supra, an actively cooled Tokamak

    International Nuclear Information System (INIS)

    Guilhem, D.; Adjeroud, B.; Balorin, C.; Buravand, Y.; Bertrand, B.; Bondil, J.L.; Desgranges, C.; Gauthier, E.; Lipa, M.; Messina, P.; Missirlian, M.; Mitteau, R.; Moulin, D.; Pocheau, C.; Portafaix, C.; Reichle, R.; Roche, H.; Saille, A.; Vallet, S.

    2004-01-01

    Tore-Supra has a steady-state magnetic field using super-conducting magnets and water-cooled plasma facing components for high performances long pulse plasma discharges. When not actively cooled, plasma-facing components can only accumulate a limited amount of energy since the temperature increase continuously (T proportional to √(t)) during the discharge until radiation cooling is equal to the incoming heat flux (T > 1800 K). Such an environment is found in most today Tokamaks. In the present paper we report the recent results of Tore-Supra, especially the design of the new generation of infrared endoscopes to measure the surface temperature of the plasma facing components. The Tore-Supra infrared thermography system is composed of 7 infrared endoscopes, this system is described in details in the paper, the new JET infrared thermography system is presented and some insights of the ITER set of visible/infrared endoscope is given. (authors)

  12. Opportunist combination of electronic technologies for real time calculations in the Tore Supra Tokamak

    International Nuclear Information System (INIS)

    Barbuti, A.; Gil, C.; Pastor, P.; Spuig, P.; Vincent, B.; Volpe, D.

    2013-06-01

    The Tore Supra tokamak real-time plasma control is based on measurements coming from various diagnostics. The complexity of all the events that occur during plasma is at the origin of measurements disturbances which have to be corrected in real time in order to ensure an optimal control. The signal correction does not just mean processing but requires complex algorithms. Electronics does not only need to process and adapt electrical signals, but it has to include corrections by mathematical calculation. The FPGA (field-programmable gate array) technology, with the help of basic adapted electronics, allows integrating the entire real time calculation and digital data transmission on the network. FMC (FPGA Mezzanine Card) coupled with in-house motherboard, which is used both as the interface with Tore Supra specific systems and as the support for other signals processing options, is the perfect answer to this request. The FMC includes a FPGA, memory, Ethernet port and multiple I/O for interfacing with the motherboard and Tore Supra signals. The algorithms are developed in VHDL (Very high speed integrated circuit Hardware Description Language), parallel process management that promotes faster calculation than a common μC (Micro-controller) in one clock pulse. The flexibility, the low cost and the implementation speed allow fitting a large number of various applications in fields where no 'off-theshelf' component can be found. And more specifically, in research and experimentation, algorithms can be continuously improved or modified for new requirements. (authors)

  13. Particle retention during long discharges in Tore Supra and JET

    International Nuclear Information System (INIS)

    Loarer, T.; Tsitrone, E.; Brosset, C.; Bucalossi, J.; Gunn, J.; Joffrin, E.; Monier-Garbet, P.; Pegourie, B.; Thomas, P.; Lomas, P.; Ongena, J.

    2003-01-01

    The particle balances and the associated particle retentions for the long discharge experiments performed in Tore-Supra and for the L and H mode discharges carried out in JET are reported in this paper. From the reported experiments, the same particle retention behaviors are observed in Tore-Supra and JET in spite of the differences between the plasma geometry and the confinement mode (respectively limiter L-mode and divertor H-mode). A particle retention up to 70-80% of Γ(puff) for the larger gas injection has been obtained in JET. The particle retention behavior observed with the gas puff appears to be strongly dominant in the particle retention process. Indeed, no influence has been noticed from the active pumping, the saturation of the recycling area (0.4 D/C), the precedent discharges history (in terms of total 'particles retained' in the vessel) and even from the disruptions (conditioning). Also, the outgassing between discharges becomes negligible in terms of particle recovering when Γ(puff) and/or the discharge duration are increased. Finally, neither the edge localized modes (ELMs type-I or III) nor the disruptions modify the reported behaviour. For ITER, the particle retention is strictly limited and from the presented results it seems that strong gas injection should be avoided. (A.C.)

  14. Utilizing Tornado Data for Classroom Exercises.

    Science.gov (United States)

    Kohler, Fred

    Exercises were developed using tornado statistics to provide students with a better understanding of the spatial and temporal characteristics of these phenomena in the United States. Four categories of exercises were considered beginning with the simplest and progressing to the more complex. The first set of exercises required students to…

  15. Tornado missile simulation and design methodology. Volume 2: model verification and data base updates. Final report

    International Nuclear Information System (INIS)

    Twisdale, L.A.; Dunn, W.L.

    1981-08-01

    A probabilistic methodology has been developed to predict the probabilities of tornado-propelled missiles impacting and damaging nuclear power plant structures. Mathematical models of each event in the tornado missile hazard have been developed and sequenced to form an integrated, time-history simulation methodology. The models are data based where feasible. The data include documented records of tornado occurrence, field observations of missile transport, results of wind tunnel experiments, and missile impact tests. Probabilistic Monte Carlo techniques are used to estimate the risk probabilities. The methodology has been encoded in the TORMIS computer code to facilitate numerical analysis and plant-specific tornado missile probability assessments

  16. Theoretical and experimental study of the hybrid wave coupling in Tore Supra and Jet by multijunction antennas

    International Nuclear Information System (INIS)

    Litaudon, X.

    1990-06-01

    The hybrid or slow electron plasma waves propagation and coupling are investigated in a toroidal magnetic confinement configuration such as found in Tokamaks. The main characteristics of the antenna, formed of several waveguides displaced in the toroidal direction, are studied. The equations of the hybrid waves linear propagation are solved for a plane geometrical configuration and in an inhomogeneous plasma. The optimization of the hybrid wave couplers of Tore Supra and Jet is carried out by means of the SWAN code. The results of the experiments performed on Tore Supra are analyzed. The investigation shows that the wave coupling depends on the edge plasma properties [fr

  17. First results of correlation electron cyclotron emission on Tore Supra

    OpenAIRE

    Udintsev, V. S.; Goniche, M.; Ségul, J.L.; Giruzzi, G.; Molina, D.; Turco, F.; Huysmans, G. T. A.; Maget, P.; Krämer-Flecken, A.

    2006-01-01

    Measurements of electron temperature fluctuations by means of correlation electron cyclotron emission (ECE) diagnostics aid in understanding the nature of the turbulent transport infusion plasmas. On Tore Supra tokamak, a 32-channel heterodyne ECE radiometer has been upgraded to include two channels for temperature fluctuation measurements. The central frequency of the yttrium iron garnet filter on each channel is remotely monitored by a driver, allowing one to shift the observation volume in...

  18. Lower hybrid wave coupling in TORE SUPRA through multijunction launchers

    International Nuclear Information System (INIS)

    Litaudon, X.; Bibet, P.; Goniche, M.

    1991-01-01

    The TORE SUPRA Lower Hybrid Current Drive experiments (8MW/3.7GHz) use large phased waveguide arrays (4 rows of 32 waveguides for each of the two 'grills') to couple the waves to the plasma. These launchers are based on the 'Multijunction' principle which allows them to be quite compact but needs to be fully assessed for the design of efficient multi-megawatt antennas in NET/ITER. (author) 5 refs., 6 figs

  19. Tornado: School Damage Tops $3 Million.

    Science.gov (United States)

    Story, Nancy

    1999-01-01

    Describes efforts by the publications staff of North Hall High School (Gainesville, Georgia) to cover a tornado and its aftermath. Notes that the first issue published after the storm focused in intrusion by the media. Suggests that an anniversary issues was more effective in achieving the emotional catharsis the school needed. (RS)

  20. Improved confinement with ion cyclotron hydrogen minority heating on Tore Supra

    International Nuclear Information System (INIS)

    Hoang, G.T.; Monier-Garbet, P.; Aniel, T.; Bourdelle, C.; Eriksson, L.G.; Garbet, X.; Grisolia, C.; Platz, P.; Budny, R.V.

    1999-02-01

    Tore Supra experiments are presently devoted to study the high density and high radiation regimes with radio frequency heating. Recent results of ion cyclotron minority heating have been obtained with an improved L-mode confinement, close to ELMy H-mode, at relatively high density (up to 80% of Greenwald limit). Such a regime is very promising as possible scenario in a next step tokamak. (authors)

  1. Laboratory Study of Topographic Effects on the Near-surface Tornado Flow Field

    Science.gov (United States)

    Razavi, Alireza; Sarkar, Partha P.

    2018-03-01

    To study topographic effects on the near-surface tornado flow field, the Iowa State University tornado simulator was used to simulate a translating tornado passing over three different two-dimensional topographies: a ridge, an escarpment and a valley. The effect of the translation speed on maximum horizontal wind speeds is observed for translation speeds of 0.15 and 0.50 m s^{-1} , with the lower value resulting in a larger maximum horizontal wind speed. The tornado translation over the three topographies with respect to flat terrain is assessed for changes in: (a) the maximum horizontal wind speeds in terms of the flow-amplification factor; (b) the maximum aerodynamic drag in terms of the tornado speed-up ratio; (c) the maximum duration of exposure at any location to high wind speeds of a specific range in terms of the exposure amplification factor. Results show that both the maximum wind amplification factor of 14%, as well as the maximum speed-up ratio of 14%, occur on the ridge. For all topographies, the increase in aerodynamic drag is observed to be maximized for low-rise buildings, which illustrates the importance of the vertical profiles of the horizontal wind speed near the ground. The maximum exposure amplification factors, estimated for the range of wind speeds corresponding to the EF2 (50-60 m s^{-1} ) and EF3 (61-75 m s^{-1}) scales, are 86 and 110% for the ridge, 4 and 60% for the escarpment and - 6 and 47% for the valley, respectively.

  2. Working after a tornado: a survey of hospital personnel in Joplin, Missouri.

    Science.gov (United States)

    Charney, Rachel; Rebmann, Terri; Flood, Robert G

    2014-01-01

    In 2011, an EF5 tornado hit Joplin, MO, requiring complete evacuation of 1 hospital and a patient surge to another. We sought to assess the resilience of healthcare workers in these hospitals as measured by number reporting to work, willingness to work, personal disaster preparedness, and childcare responsibilities following the disaster. In May 2013, a survey was distributed to healthcare workers at both Joplin hospitals that asked them to report their willingness to work and personal disaster preparedness following various disaster scenarios. For those with childcare responsibilities, scheduling, costs, and impact of hypothetical alternative childcare programs were considered in the analyses. A total of 1,234 healthcare workers completed the survey (response rate: 23.4%). Most (87.8%) worked the week following the Joplin tornado. Healthcare workers report more willingness to work during a future earthquake or tornado compared to their pre-Joplin tornado attitudes (86.2 vs 88.4%, t=-4.3, ptornado personal disaster preparedness, but only preevent preparedness was a significant predictor of postevent preparedness. Nearly half (48.5%, n=598) had childcare responsibilities; 61% (n=366) had childcare needs the week of the tornado, and 54% (n=198) required the use of alternative childcare. If their hospital had provided alternative childcare, 51% would have used it and 42% felt they would have been more willing to report to work. Most healthcare workers reported to work following this disaster, demonstrating true resilience. Disaster planners should be aware of these perceptions as they formulate their own emergency operation plans.

  3. Doppler Radar and Cloud-to-Ground Lightning Observations of a Severe Outbreak of Tropical Cyclone Tornadoes

    Science.gov (United States)

    McCaul, Eugene W., Jr.; Buechler, Dennis; Cammarata, Michael; Arnold, James E. (Technical Monitor)

    2002-01-01

    Data from a single WSR-88D Doppler radar and the National Lightning Detection Network are used to examine the characteristics of the convective storms that produced a severe tornado outbreak within Tropical Storm Beryl's remnants on 16 August 1994. Comparison of the radar data with reports of tornadoes suggests that only 12 cells produced the 29 tornadoes that were documented in Georgia and the Carolinas on that date. Six of these cells spawned multiple tornadoes, and the radar data confirm the presence of miniature supercells. One of the cells was identifiable on radar for 11 hours, spawning tornadoes over a time period spanning approximately 6.5 hours. Time-height analyses of the three strongest supercells are presented in order to document storm kinematic structure and evolution. These Beryl mini-supercells were comparable in radar-observed intensity but much more persistent than other tropical cyclone-spawned tornadic cells documented thus far with Doppler radars. Cloud-to-ground lightning data are also examined for all the tornadic cells in this severe swarm-type tornado outbreak. These data show many of the characteristics of previously reported heavy-precipitation supercells. Lightning rates were weak to moderate, even in the more intense supercells, and in all the storms the lightning flashes were almost entirely negative in polarity. No lightning at all was detected in some of the single-tornado storms. In the stronger cells, there is some evidence that lightning rates can decrease during tornadogenesis, as has been documented before in some midlatitude tornadic storms. A number of the storms spawned tornadoes just after producing their final cloud-to-ground lightning flashes. These findings suggest possible benefits from implementation of observing systems capable of monitoring intracloud as well as cloud-to-ground lightning activity.

  4. Global analysis of ICRF wave coupling on Tore Supra

    International Nuclear Information System (INIS)

    Goniche, M.; Bremond, S.; Colas, L.

    2003-01-01

    The Tore Supra tokamak is equipped with a multi-megawatt ion cyclotron range of frequency (ICRF) system for heating and current drive. The coupling of the fast wave to the plasma, characterized by the distributed coupling resistance along the radiating straps, is a crucial issue in order to launch large RF powers. Many factors can have an effect on ICRF wave coupling. Quantitative prediction from theoretical modelling requires the knowledge of the local inhomogeneous plasma density profile in front of the antenna for running sophisticated antenna codes. In this work, we have rather followed a 'global' approach, based on Tore Supra experimental results, for the parametric study of the coupling resistance. From a large data base covering seven experimental campaigns (∼2250 shots), a scaling law of the coupling resistance including the main parameters of the plasma and of the antenna configuration is established. This approach is found to be reliable for the analysis of coupling in the different scenarios: He/D 2 gas filling, gas/pellets for plasma fuelling, plasma leaning on inner wall/low field side limiter, limiter/ergodic divertor configuration, minority heating/direct electron heating. From one scenario to another, a significant variation of the coefficients of the scaling law is found. The study of these variations allows to get some insight on the main physical mechanisms which influence the ICRF wave coupling in a tokamak operation, such as the wall conditioning and recycling conditions, RF sheaths or frequency. (author)

  5. Carbon source from the toroidal pumped limiter during long discharge operation in Tore Supra

    International Nuclear Information System (INIS)

    Dufour, E.; Brosset, C.; Lowry, C.; Bucalossi, J.; Chappuis, P.; Corre, Y.; Desgranges, C.; Guirlet, R.; Gunn, J.; Loarer, T.; Mitteau, R.; Monier-Garbet, P.; Pegourie, B.; Reichle, R.; Thomas, P.; Tsitrone, E.; Hogan, J.; Roubin, P.; Martin, C.; Arnas, C.

    2005-01-01

    A better understanding of deuterium retention mechanisms requires the knowledge of carbon sources in Tore-Supra. The main source of carbon in the vacuum vessel during long discharges is the toroidal pumped limiter (TPL). This work is devoted to the experimental characterisation of the carbon source from the TPL surface during long discharges using a visible spectroscopy diagnostic. Moreover, we present an attempt to perform a carbon balance over a typical campaign and we discuss it with regards to the deuterium in-vessel inventory deduced from particle balance and the deuterium content of the deposited layers. The study shows that only a third of the estimated deuterium trapped in the vessel is trapped in the carbon deposits. Thus, in the present state of our knowledge and characterisation of the permanent retention, one has to search for mechanisms other than co-deposition to explain the deuterium retention in Tore Supra. (A.C.)

  6. ON THE MAGNETISM AND DYNAMICS OF PROMINENCE LEGS HOSTING TORNADOES

    International Nuclear Information System (INIS)

    Martínez González, M. J.; Ramos, A. Asensio; Arregui, I.; Collados, M.; Beck, C.; Rodríguez, J. de la Cruz

    2016-01-01

    Solar tornadoes are dark vertical filamentary structures observed in the extreme ultraviolet associated with prominence legs and filament barbs. Their true nature and relationship to prominences requires an understanding of their magnetic structure and dynamic properties. Recently, a controversy has arisen: is the magnetic field organized forming vertical, helical structures or is it dominantly horizontal? And concerning their dynamics, are tornadoes really rotating or is it just a visual illusion? Here we analyze four consecutive spectro-polarimetric scans of a prominence hosting tornadoes on its legs, which helps us shed some light on their magnetic and dynamical properties. We show that the magnetic field is very smooth in all the prominence, which is probably an intrinsic property of the coronal field. The prominence legs have vertical helical fields that show slow temporal variation that is probably related to the motion of the fibrils. Concerning the dynamics, we argue that (1) if rotation exists, it is intermittent, lasting no more than one hour, and (2) the observed velocity pattern is also consistent with an oscillatory velocity pattern (waves).

  7. ON THE MAGNETISM AND DYNAMICS OF PROMINENCE LEGS HOSTING TORNADOES

    Energy Technology Data Exchange (ETDEWEB)

    Martínez González, M. J.; Ramos, A. Asensio; Arregui, I.; Collados, M. [Instituto de Astrofísica de Canarias, Vía Láctea s/n, E-38205 La Laguna, Tenerife (Spain); Beck, C. [National Solar Observatory, Sacramento Peak P.O. Box 62, Sunspot, NM 88349 (United States); Rodríguez, J. de la Cruz [Institute for Solar Physics, Department of Astronomy, Stockholm University, Albanova University Center, SE-10691 Stockholm (Sweden)

    2016-07-10

    Solar tornadoes are dark vertical filamentary structures observed in the extreme ultraviolet associated with prominence legs and filament barbs. Their true nature and relationship to prominences requires an understanding of their magnetic structure and dynamic properties. Recently, a controversy has arisen: is the magnetic field organized forming vertical, helical structures or is it dominantly horizontal? And concerning their dynamics, are tornadoes really rotating or is it just a visual illusion? Here we analyze four consecutive spectro-polarimetric scans of a prominence hosting tornadoes on its legs, which helps us shed some light on their magnetic and dynamical properties. We show that the magnetic field is very smooth in all the prominence, which is probably an intrinsic property of the coronal field. The prominence legs have vertical helical fields that show slow temporal variation that is probably related to the motion of the fibrils. Concerning the dynamics, we argue that (1) if rotation exists, it is intermittent, lasting no more than one hour, and (2) the observed velocity pattern is also consistent with an oscillatory velocity pattern (waves).

  8. Collection and Characterization of Particulate from the Tore Supra Tokamak (Dec. 1999 Vent)

    International Nuclear Information System (INIS)

    Sharpe, John Phillip

    2002-01-01

    Particulate generated during the operation of a fusion device contributes to the radiological source term associated with accident scenarios in the device. Understanding the mechanisms generating the particulate and correctly describing its physical and chemical behavior is essential for safety analyses of future fusion devices. Knowledge of these mechanisms is gained by collecting and characterizing particulate matter from operating fusion facilities. Tokamak dust, the particulate matter generated during the operation of a tokamak fusion device, was collected from Tore Supra in December 1999, during the initial phase of the scheduled shutdown for installation of advanced plasma facing components. Tore Supra, located at CEA Cadarache, France, is presently the third largest operating tokamak with the capability of long-pulse operation. Eighteen super-conducting coils produce the 4.5 T magnetic field inside a vessel 2.4 m in major radius and 1.2 m in minor radius. Limiter and divertor regimes of operation are possible. In the divertor regime, the circular magnetic configuration is ergodized by six outboard resonant divertor modules that are covered with 12 m2 of carbon fiber composite (CFC) tiles. In addition, some field lines are diverted to actively cooled neutralizing plates made of CuCrZr bars covered with B4C. In the limiter regime, the plasma leans on the actively cooled inboard first wall or on a set of inertially cooled pumped limiters. The first wall area of 12 m2 is covered with both polycrystalline graphite tiles (83%) and CFC tiles (17%). The single outboard limiter is constructed of pyrolitic graphite, and the four toroidally symmetric bottom limiters are constructed of CFC. Figure 1.1 displays the relative location of plasma facing components within the plasma chamber of Tore Supra. In this report, we present in Section 2 the methods used to collect and analyze this dust and describe the selection of sampling locations. Section 3 includes a discussion

  9. TORE-SUPRA: design of thermal radiation shield at 80 K

    International Nuclear Information System (INIS)

    Aymar, R.; Cordier, J.J.; Deschamps, P.; Gauthier, A.; Perin, J.P.

    1982-09-01

    The TORE-SUPRA superconducting toroidal magnet operating at liquid helium temperature, must be protected against thermal radiation from the vessels. For this purpose, stainless steel heat shields, cooled at 80 K, are positioned between coil casings at 4.5 K and the vessels, and constitute a double stiff toroid which completely surrounds the magnet. Mockups have been manufactured to study their design and operating problems. Calculations have also been made to analyse the mechanical behaviour of these shields

  10. Characterization of the wind loads and flow fields around a gable-roof building model in tornado-like winds

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Hui; Yang, Zifeng; Sarkar, Partha [Iowa State University, Department of Aerospace Engineering, Ames, IA (United States); Haan, Fred [Iowa State University, Department of Aerospace Engineering, Ames, IA (United States); Rose-Hulman Institute of Technology, Department of Mechanical Engineering, Terre Haute, IN (United States)

    2011-09-15

    An experimental study was conducted to quantify the characteristics of a tornado-like vortex and to reveal the dynamics of the flow-structure interactions between a low-rise, gable-roof building model and swirling, turbulent tornado-like winds. The experimental work was conducted by using a large-scale tornado simulator located in the Aerospace Engineering Department of Iowa State University. In addition to measuring the pressure distributions and resultant wind loads acting on the building model, a digital Particle Image Velocimetry system was used to conduct detailed flow field measurements to quantify the evolution of the unsteady vortices and turbulent flow structures around the gable-roof building model in tornado-like winds. The effects of important parameters, such as the distance between the centers of the tornado-like vortex and the test model and the orientation angles of the building model related to the tornado-like vortex, on the evolutions of the wake vortices and turbulent flow structures around the gable-roof building model as well as the wind loads induced by the tornado-like vortex were assessed quantitatively. The detailed flow field measurements were correlated with the surface pressure and wind load measurements to elucidate the underlying physics to gain further insight into flow-structure interactions between the gable-roof building model and tornado-like winds in order to provide more accurate prediction of wind damage potential to built structures. (orig.)

  11. Connexion topology and sol physics induced by the ergodic divertor in Tore Supra

    International Nuclear Information System (INIS)

    Nguyen, F.; Ghendrih, P.; Samain, A.

    1990-01-01

    The diffuse connexion induced by the ergodic divertor in Tore Supra leads to heat load patterns on the plasma facing components. The topology of those patterns is analysed using field line tracing and analytical derivation of effective heat transport coefficients. Control of the heat load via the magnetic configuration is investigated

  12. Plasma density control with ergodic divertor on Tore Supra; Controle de la densite du plasma en presence du divertor ergodique dans le tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Meslin, B

    1998-04-30

    Plasma density control on the tokamak Tore Supra is important for the optimization of every experimental scenario dealing with the improvement of plasma performances. Specific conditions are required both in the plasma bulk and at the edge. Within the framework of the present study, a magnetic configuration is used in the e plasma edge of Tore Supra: the ergodic divertor configuration. A magnetic perturbation which is resonant with the permanent field destroys the plasma confinement locally, opening the field lines onto the material components. They aim of the study is the characterization of the edge density in every relevant scenario for Tore Supra. The first part of this work is dedicated to density and temperature measurements by a series of fixed Langmuir probes located at the very edge of the plasma. Thanks to them, density regimes have been put in evidence during experiments where the volume averaged density , an usual control parameter of the plasma, was varied. The analysis of heat and particle transport through the plasma edge region explains the mechanisms leading to those regimes. The essential factor in our analysis is the dependence of the electron conductivity and ionization depth on temperature. While heat conduction governs the heat transport, the edge density varies linearly according to . Below a critical temperature, reached when the ion flux amplification at constant power density is large enough, a parallel temperature gradient appears leading to a density gradient in the opposite direction in order to maintain the pressure constant along the field lines. A high recycling regime is obtained and the edge density varies like {sup 3}. The pressure conservation is no more satisfied during the detachment of the plasma, which is characterized by a high neutral density at low temperatures leading to a ion momentum loss by friction against the neutrals. The edge density drops in those conditions. These regimes are similar

  13. The design of the helium refrigerator for TORE SUPRA

    International Nuclear Information System (INIS)

    Gistau, G.M.; Claudet, G.

    1984-01-01

    The special cryogenic requirements of TORE SUPRA have called for novel solutions. Pumping the 1,75 K (13 mb) helium bath is achieved by the use of a pair of centrifugal pumps operating at very low temperature, backed up by liquid rings pumps at room temperature. Four oil-lubricated screw compressors mounted in series-parallel form the main cycle helium compression set. The Joule-Thomson expansion valve is replaced by a mechanical expansion engine working with a bi-phase exhaust. The control of the refrigeration system is entirely automatic

  14. Tornado Damage Assessment: Reconstructing the Wind Through Debris Tracking and Treefall Pattern Analysis

    Science.gov (United States)

    Godfrey, C. M.; Peterson, C. J.; Lombardo, F.

    2017-12-01

    Efforts to enhance the resilience of communities to tornadoes requires an understanding of the interconnected nature of debris and damage propagation in both the built and natural environment. A first step toward characterizing the interconnectedness of these elements within a given community involves detailed post-event surveys of tornado damage. Such damage surveys immediately followed the 22 January 2017 EF3 tornadoes in the southern Georgia towns of Nashville and Albany. After assigning EF-scale ratings to impacted structures, the authors geotagged hundreds of pieces of debris scattered around selected residential structures and outbuildings in each neighborhood and paired each piece of debris with its source structure. Detailed information on trees in the vicinity of the structures supplements the debris data, including the species, dimensions, location, fall direction, and level of damage. High-resolution satellite imagery helps to identify the location and fall direction of hundreds of additional forest trees. These debris and treefall patterns allow an estimation of the near-surface wind field using a Rankine vortex model coupled with both a tree stability model and an infrastructure fragility model that simulates debris flight. Comparisons between the modeled damage and the actual treefall and debris field show remarkable similarities for a selected set of vortex parameters, indicating the viability of this approach for estimating enhanced Fujita scale levels, determining the near-surface wind field of a tornado during its passage through a neighborhood, and identifying how debris may contribute to the overall risk from tornadoes.

  15. ARE TORNADO-LIKE MAGNETIC STRUCTURES ABLE TO SUPPORT SOLAR PROMINENCE PLASMA?

    Energy Technology Data Exchange (ETDEWEB)

    Luna, M.; Moreno-Insertis, F. [Instituto de Astrofísica de Canarias, E-38200 La Laguna, Tenerife (Spain); Priest, E. [Mathematics Institute, University of St Andrews, St Andrews KY16 9SS (United Kingdom)

    2015-07-20

    Recent high-resolution and high-cadence observations have surprisingly suggested that prominence barbs exhibit apparent rotating motions suggestive of a tornado-like structure. Additional evidence has been provided by Doppler measurements. The observations reveal opposite velocities for both hot and cool plasma on the two sides of a prominence barb. This motion is persistent for several hours and has been interpreted in terms of rotational motion of prominence feet. Several authors suggest that such barb motions are rotating helical structures around a vertical axis similar to tornadoes on Earth. One of the difficulties of such a proposal is how to support cool prominence plasma in almost-vertical structures against gravity. In this work we model analytically a tornado-like structure and try to determine possible mechanisms to support the prominence plasma. We have found that the Lorentz force can indeed support the barb plasma provided the magnetic structure is sufficiently twisted and/or significant poloidal flows are present.

  16. Facebook and Twitter, communication and shelter, and the 2011 Tuscaloosa tornado.

    Science.gov (United States)

    Stokes, Courtney; Senkbeil, Jason C

    2017-01-01

    This paper represents one of the first attempts to analyse the many ways in which Facebook and Twitter were used during a tornado disaster. Comparisons between five randomly selected campus samples and a city of Tuscaloosa, Alabama, sample revealed that campus samples used Facebook and Twitter significantly more both before and after the tornado, but Facebook usage was not significantly different after the event. Furthermore, differences in social media usage and other forms of communication before the tornado were found for age, education, and years lived in Tuscaloosa. Generally, age and education were inversely proportionate to social media usage. Influences on shelter-seeking actions varied between social media users and three random samples of non-social media users; however, it appears that social media respondents were likely to be using a smartphone simultaneously to access warning polygon information, to receive text message alerts, and to listen or respond to environmental cues. © 2017 The Author(s). Disasters © Overseas Development Institute, 2017.

  17. ARE TORNADO-LIKE MAGNETIC STRUCTURES ABLE TO SUPPORT SOLAR PROMINENCE PLASMA?

    International Nuclear Information System (INIS)

    Luna, M.; Moreno-Insertis, F.; Priest, E.

    2015-01-01

    Recent high-resolution and high-cadence observations have surprisingly suggested that prominence barbs exhibit apparent rotating motions suggestive of a tornado-like structure. Additional evidence has been provided by Doppler measurements. The observations reveal opposite velocities for both hot and cool plasma on the two sides of a prominence barb. This motion is persistent for several hours and has been interpreted in terms of rotational motion of prominence feet. Several authors suggest that such barb motions are rotating helical structures around a vertical axis similar to tornadoes on Earth. One of the difficulties of such a proposal is how to support cool prominence plasma in almost-vertical structures against gravity. In this work we model analytically a tornado-like structure and try to determine possible mechanisms to support the prominence plasma. We have found that the Lorentz force can indeed support the barb plasma provided the magnetic structure is sufficiently twisted and/or significant poloidal flows are present

  18. Are Tornado-Like Magnetic Structures Able to Support Solar Prominence Plasma?

    Science.gov (United States)

    Ogunjo, S. T.; Luna Bennasar, M.; Moreno-Insertis, F.; Priest, E. R.

    2015-12-01

    Recent high-resolution and high-cadence observations have surprisingly suggested that prominence barbs exhibit apparent rotating motions suggestive of a tornado-like structure. Additional evidence has been provided by Doppler measurements. The observations reveal opposite velocities for both hot and cool plasma on the two sides of a prominence barb. This motion is persistent for several hours and has been interpreted in terms of rotational motion of prominence feet. Several authors suggest that such barb motions are rotating helical structures around a vertical axis similar to tornadoes on Earth. One of the difficulties of such a proposal is how to support cool prominence plasma in almost-vertical structures against gravity. In this work we model analytically a tornado-like structure and try to determine possible mechanisms to support the prominence plasma. We have found that the Lorentz force can indeed support the barb plasma provided the magnetic structure is sufficiently twisted and/or significant poloidal flows are present.

  19. Calibration of Fabry-Perot interferometers for electron cyclotron emission measurements on the Tore Supra tokamak

    International Nuclear Information System (INIS)

    Javon, C.; Talvard, M.

    1990-01-01

    The electron temperature is routinely measured on TORE SUPRA using Fabry-Perot cavities. These have been calibrated using a technique involving coherent addition and Fourier analysis of a chopped black-body source. Comparison with conventional techniques is reported

  20. TORNADO-LIKE EVOLUTION OF A KINK-UNSTABLE SOLAR PROMINENCE

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wensi; Liu, Rui; Wang, Yuming, E-mail: rliu@ustc.edu.cn [CAS Key Laboratory of Geospace Environment, Department of Geophysics and Planetary Sciences, University of Science and Technology of China, Hefei 230026 (China)

    2017-01-01

    We report on the tornado-like evolution of a quiescent prominence on 2014 November 1. The eastern section of the prominence first rose slowly, transforming into an arch-shaped structure as high as ∼150 Mm above the limb; the arch then writhed moderately in a left-handed sense, while the original dark prominence material emitted in the Fe ix 171 Å passband, and a braided structure appeared at the eastern edge of the warped arch. The unraveling of the braided structure was associated with a transient brightening in the EUV and apparently contributed to the formation of a curtain-like structure (CLS). The CLS consisted of myriad thread-like loops rotating counterclockwise about the vertical if viewed from above. Heated prominence material was observed to slide along these loops and land outside the filament channel. The tornado eventually disintegrated and the remaining material flew along a left-handed helical path constituting approximately a full turn, as corroborated through stereoscopic reconstruction, into the cavity of the stable, western section of the prominence. We suggest that the tornado-like evolution of the prominence was governed by the helical kink instability, and that the CLS formed through magnetic reconnections between the prominence field and the overlying coronal field.

  1. Near infrared thermography by CCD cameras and application to first wall components of Tore Supra tokamak

    International Nuclear Information System (INIS)

    Moreau, F.

    1996-01-01

    In the Tokamak TORE-SUPRA, the plasma facing components absorbs and evacuate (active cooling) high power fluxes (up to 10 MW/m 2 ). Their thermal behavior study is essential for the success of controlled thermonuclear fusion line. The first part is devoted to the study of power deposition on the TORE-SUPRA actively cooled limiters. A model of power deposition on one of the limiters is developed. It Takes into account the magnetic topology and a description of the plasma edge. The model is validated with experimental calorimetric data obtained during a series of shots. This will allow to compare the surface temperature measurements with the predicted ones. The main purpose of this thesis was to evaluate and develop a new surface temperature measurement system. It works in the near infrared range (890 nm) and is designed to complete the existing thermographic diagnostic of TORE-SUPRA. By using the radiation laws (for a blackbody and the plasma) ant the laboratory calibration one can estimate the surface temperature of the observed object. We evaluate the performances and limits of such a device in the harsh conditions encountered in a Tokamak environment. On the one hand, in a quasi ideal situation, this analysis shows that the range of measurement is 600 deg. C to 2500 deg. C. On the other hand, when one takes into account of the plasma radiation (with an averaged central plasma density of 6.10 19 m -3 ), we find that the minimum surface temperature rise to 900 deg. C. In the near future, according to the development of IR-CCD cameras working in the near infrared range up to 2 micrometers, we will be able to keep the good spatial resolution with an improved lower limit for the temperature down to 150 deg. C. The last section deals with a number of computer tools to process the images obtained from experiments on TORE-SUPRA. A pattern recognition application was especially developed to detect a complex plasma iso-intensity structure. (author)

  2. Near infrared thermography by CCD cameras and application to first wall components of Tore Supra tokamak

    International Nuclear Information System (INIS)

    Moreau, F.

    1996-01-01

    In the Tokamak TORE-SUPRA, the plasma facing components absorbs and evacuate (active cooling) high power fluxes (up to 10 MW/m 2 ). Their thermal behavior study is essential for the success of controlled thermonuclear fusion line. The first part is devoted to the study of power deposition on the TORE-SUPRA actively cooled limiters. A model of power deposition on one of the limiters is developed. It takes into account the magnetic topology and a description of the plasma edge. The model is validated with experimental calorimetric data obtained during a series of shots. This will allow to compare the surface temperature measurements with the predicted ones. The main purpose of this thesis was to evaluate and develop a new temperature measurement system. It works in the near infrared range (890 nm) and is designed to complete the existing thermographic diagnostic of TORE-SUPRA. By using the radiation laws (for a blackbody and the plasma) and the laboratory calibration one can estimate the surface temperature of the observed object. We evaluate the performances and limits of such a device in the harsh conditions encountered in a Tokamak environment. On the one hand, in a quasi ideal situation, this analysis shows that the range of measurements is 600 deg. C to 2500 deg. C. On the other hand, when one takes into account of the plasma radiation (with an averaged central plasma density of 6.10 19 m -3 ), we find that the minimum surface temperature rise to 900 deg. C instead of 700 deg. C. In the near future, according to the development of IR-CCD cameras working in the near infrared range up to 2 micrometers, we will be able to keep the good spatial resolution with an improved lower limit for the temperature down to 150 deg. C. The last section deals with a number of computer tools to process the images obtained from experiments on TORE-SUPRA. A pattern recognition application was especially developed to detect a complex plasma iso-intensity structure. (author)

  3. Full steady state LH scenarios in Tore Supra

    International Nuclear Information System (INIS)

    Kazarian-Vibert, F.; Litaudon, X.; Arslanbekov, R.; Hoang, G.T.; Moreau, D.; Peysson, Y.

    1995-01-01

    Lower Hybrid discharge have been realised in Tore Supra using feed-back control of the primary circuit voltage such that the loop voltage was maintained exactly to zero near the plasma surface. This new scenario allows the plasma current to float and quickly reach an equilibrium value determined by the current drive efficiency and Lower Hybrid power. Recent experimental results show that, with the new constant flux scenario the coupled plasma and primary currents reach a steady state in less than 10 s which is a good agreement with theoretical expectations. A complete analysis of this scenario is presented. (authors). 8 refs., 3 figs

  4. Radiant heat exchange measurements for Tore Supra

    International Nuclear Information System (INIS)

    Chatain, D.; Disdier, F.; Gauthier, A.; Raffin, M.; Renaud, M.

    1984-03-01

    In order to minimize the energy consumption of the low temperature cryogenic system connected to the superconducting magnet of TORE-SUPRA, heat exchange from thermal radiation between the vacuum vessels and the thermal shields has been studied. Accordingly large scale cold and hot walls of T.S. have been simulated in a model with reduced dimensions. In this model, the experiment consists in the measurement of the thermal radiated power between two concentric cylindrical surfaces of stainless steel under vacuum conditions. The temperature of the external cylinder was kept constant at 80 K. The internal cylinder was bakeable up to 250 0 C. Various surface treatments were applied on the two cylinders (mechanical polishing and metal deposition of Al, Ag, Ni) [fr

  5. Analyses of metallic first mirror samples after long term plasma exposure in Tore Supra

    International Nuclear Information System (INIS)

    Lipa, M.; Schunke, B.; Gil, Ch.; Bucalossi, J.; Voitsenya, V.S.; Konovalov, V.; Vukolov, K.; Balden, M.; De Temmerman, G.; Oelhafen, P.; Litnovsky, A.; Wienhold, P.

    2006-01-01

    Metallic mirrors are foreseen in ITER diagnostic systems as optical elements directly viewing the plasma radiation. In the frame of an EFDA contract, metallic mirror samples have been exposed for long pulse plasma discharges in Tore Supra (TS) in order to investigate surface modifications caused by erosion and re-deposition processes. Three different materials have been selected: mono-crystalline molybdenum (mc-Mo), polycrystalline stainless steel (SS) and copper (Cu). The mc-Mo samples showed after TS exposure almost no surface roughness modifications and the lowest net-erosion. A slight reflectivity reduction, most pronounced in the near UV, is attributed to light absorption in a thin carbon deposit. Cu mirrors showed by far the highest surface roughness, erosion and diffusive reflectivity. Comparative laboratory glow discharge experiments with virgin reference samples and numerical simulations of erosion/deposition confirm the dominant contribution of conditioning procedures to erosion of mirrors exposed (without shutter protection) in Tore Supra

  6. Tornado Emergency Readiness Planning for Schools.

    Science.gov (United States)

    Wisconsin State Dept. of Public Instruction, Madison.

    A place of safe refuge in the event of violent natural forces or a tornado should be included in the design of all new school buildings. Existing a school buildings should be analyzed by the architect, contractor, or engineer to determine if a safe place exists or if one can be readily adapted. Most criteria for fallout shelters are the same for…

  7. Study of heat flux deposition in the Tore Supra Tokamak; Etude des depots de chaleur dans le tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Carpentier, S.

    2009-02-15

    Accurate measurements of heat loads on internal tokamak components is essential for protection of the device during steady state operation. The optimisation of experimental scenarios also requires an in depth understanding of the physical mechanisms governing the heat flux deposition on the walls. The objective of this study is a detailed characterisation of the heat flux to plasma facing components (PFC) of the Tore Supra tokamak. The power deposited onto Tore Supra PFCs is calculated using an inverse method, which is applied to both the temperature maps measured by infrared thermography and to the enthalpy signals from calorimetry. The derived experimental heat flux maps calculated on the toroidal pumped limiter (TPL) are then compared with theoretical heat flux density distributions from a standard SOL-model. They are two experimental observations that are not consistent with the model: significant heat flux outside the theoretical wetted area, and heat load peaking close to the tangency point between the TPL and the last closed field surface (LCFS). An experimental analysis for several discharges with variable security factors q is made. In the area consistent with the theoretical predictions, this parametric study shows a clear dependence between the heat flux length lambda{sub q} (estimated in the SOL (scrape-off layer) from the IR measurements) and the magnetic configuration. We observe that the spreading of heat fluxes on the component is compensated by a reduction of the power decay length lambda{sub q} in the SOL when q decreases. On the other hand, in the area where the derived experimental heat loads are not consistent with the theoretical predictions, we observe that the spreading of heat fluxes outside the theoretical boundary increases when q decreases, and is thus not counterbalanced. (author)

  8. Toward better assessment of tornado potential in typhoons: Significance of considering entrainment effects for CAPE

    Science.gov (United States)

    Sueki, Kenta; Niino, Hiroshi

    2016-12-01

    The characteristics of typhoons that spawned tornadoes (tornadic typhoons: TTs) in Japan from 1991 to 2013 were investigated by composite analysis using the Japanese 55 year Reanalysis and compared with those of typhoons that did not spawn tornadoes (nontornadic typhoons: NTs). We found that convective available potential energy (CAPE), which considers the effects of entrainment (entraining CAPE: E-CAPE), and storm-relative environmental helicity (SREH) are significantly large in the northeast quadrant of TTs where tornadoes frequently occur and that E-CAPE and SREH in that quadrant for TTs are larger than those for NTs. On the other hand, ordinary CAPE without entrainment does not account for the spatial distribution of tornado occurrences nor does it distinguish TTs from NTs. E-CAPE is sensitive to humidity in the midtroposphere; thus, it is effective for detecting a conditionally unstable layer up to about 550 hPa, which is distinctive of TTs.

  9. Steady-state operation of tokamaks: Key physics and technology developments on Tore Supra

    International Nuclear Information System (INIS)

    Jacquinot, J.

    2005-01-01

    Important technological and physics issues related to long pulse operation required for a reactor are now being addressed in Tore Supra. experimental results in conditions where all the plasma facing components are actively cooled during pulses exceeding six minutes. Important physics issues related to continuous operation are observed in non inductively driven plasmas. (author)

  10. Impact of dual-polarization radar technology and Twitter on the Hattiesburg, Mississippi tornado.

    Science.gov (United States)

    Cates, Alexis L; Arnold, Brent W; Cooper, Guy Paul; Yeager, Violet; Stake, Josh; Ali, Mohammed; Calderone, Richard C; Wilkinson, James; Hsu, Edbert; Parrillo, Steven; Piper, Steven; Subbarao, Italo

    2013-12-01

    Dual-Polarization Radar and Twitter were analyzed to determine the impact on injuries sustained by the Hattiesburg EF-4 tornado. Tracking data provided from the Dual-Pol radar systems in National Weather Service Jackson were reviewed. Twitter data from four local Twitter handles were obtained. The change in tweets and followers for the day of the storm were compared to historical averages. A Student t-test was utilized in determining statistical significance (ptornado. An Injury Severity Score (ISS) was calculated for trauma records related to the tornado. Radar detection of the tornado gave approximately 30 minutes of advanced warning time. Statistical significance in follower growth was seen in all four Twitter handles. Out of 50 patients, the average ISS was 3.9 with a range of 1 to 29. There were zero fatalities. An ISS average of 3.9 was significantly less than two previous tornadoes of similar strength that occurred prior to increased usage of Dual-pol radar and Twitter as a means for communicating severe weather information. Early detection from Dual-pol radar improved warning time. Tweets informed citizens to seek appropriate shelter. (Disaster Med Public Health Preparedness. 2013;7:585-592).

  11. Tornado Warning Perception and Response: Integrating the Roles of Visual Design, Demographics, and Hazard Experience.

    Science.gov (United States)

    Schumann, Ronald L; Ash, Kevin D; Bowser, Gregg C

    2018-02-01

    Recent advancements in severe weather detection and warning dissemination technologies have reduced, but not eliminated, large-casualty tornado hazards in the United States. Research on warning cognition and behavioral response by the public has the potential to further reduce tornado-related deaths and injuries; however, less research has been conducted in this area compared to tornado research in the physical sciences. Extant research in this vein tends to bifurcate. One branch of studies derives from classic risk perception, which investigates cognitive, affective, and sociocultural factors in relation to concern and preparation for uncertain risks. Another branch focuses on psychological, social, and cultural factors implicated in warning response for rapid onset hazards, with attention paid to previous experience and message design. Few studies link risk perceptions with cognition and response as elicited by specific examples of warnings. The present study unites risk perception, cognition, and response approaches by testing the contributions of hypothesized warning response drivers in one set of path models. Warning response is approximated by perceived fear and intended protective action as reported by survey respondents when exposed to hypothetical tornado warning scenarios. This study considers the roles of hazard knowledge acquisition, information-seeking behaviors, previous experience, and sociodemographic factors while controlling for the effects of the visual warning graphic. Findings from the study indicate the primacy of a user's visual interpretation of a warning graphic in shaping tornado warning response. Results also suggest that information-seeking habits, previous tornado experience, and local disaster culture play strong influencing roles in warning response. © 2017 Society for Risk Analysis.

  12. Replacement of the instrumentation and control system of Tore Supra; Remplacement du systeme de controle commande de Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P

    1995-02-01

    The control system of the Tore-Supra is a wide and complex system that cannot be interrupted while running without significant consequences on the operating of the machine. Replacing the current system cannot be achieved in a global way without immobilisation and high costs. Therefore partial changes have been decided on. This work presents the detailed analysis of the arrangements and the operating of the system that will be replaced: the pro`s and con`s that have appeared through experience are related. The possibilities that the new apparatus offers are also examined. A method of step by step replacements had to be set up in order to assess the means, funds, term of achievement, performance and quality of the overall project. (TEC). 15 refs., 29 figs.

  13. A long-period analog integrator for magnetic measurements in Tore Supra

    International Nuclear Information System (INIS)

    Prou, M.; Barth, E.; Couturier, P.; Ouvrier-Buffet, P.

    1998-01-01

    A new analog integrator, called 'Integrateur 2000', has been developed for precise integration over long periods for the magnetic signals of Tore Supra with the aim of 1000 s discharges for the CIEL project. This new integrator is already in routine use for the present pulse lengths of up to 200 s in T-S, and tests have been carried out up to 1000 s with less than 2 mV of drift. (author)

  14. Experiment and Modelling of Itb Phenomena with Eccd on Tore Supra

    Science.gov (United States)

    Turco, F.; Giruzzi, G.; Artaud, J.-F.; Huysmans, G.; Imbeaux, F.; Maget, P.; Mazon, D.; Segui, J.-L.

    2009-04-01

    An extensive database of Tore Supra discharges with Internal Transport Barriers (ITBs) has been analysed. A tight correlation has been found, which links the central value of q and the creation of an ITB, while no correspondence with magnetic shear or qmin values can be inferred. In the case of incomplete transition to ITB (O-regime), modelling in presence of ECCD confirms the experimental observations about triggering/stopping and amplifying the oscillations.

  15. Reversed magnetic shear operation with ICRF minority heating on Tore Supra

    International Nuclear Information System (INIS)

    Hoang, G.T.; Antar, G.; Aniel, T.

    1999-01-01

    This paper reports a scenario recently investigated in Tore Supra for high density and high plasma current (Ip) operation, which allows to use the ion cyclotron resonance frequency (ICRF) minority heating only for the internal transport barrier (ITB) formation. The main aim is to perform a hollow current density profile by minimizing the edge resistive skin depth during the rapid Ip ramp-up, i-e efficient freezing of the resistive current diffusion

  16. A study on the regionalization of tornadogenesis for the domestic largest scale of tornado

    International Nuclear Information System (INIS)

    Sugimoto, Soichiro; Nohara, Daisuke; Hirakuchi, Hiromaru

    2014-01-01

    A new regulatory guide has been issued by the Nuclear Regulation Authority of Japan since the last year. According to this guide, electric power companies have to assess the influence of tornadoes on their nuclear power plants for operation. The purpose of this study is to evaluate the likelihood of the occurrence of F3 tornadoes, which are the largest encountered in Japan, and to consider the possibility of the regionalization of the maximum wind speed. Then, mesoscale analysis with a numerical meteorological model and re-analysis data is performed along with synoptic scale analysis. Especially, tornado parameters such as SReH (Storm Relative Helicity) and CAPE (Convective Available Potential Energy) are used for evaluating the potential tornadogenesis of F3 tornado. Both analyses indicate that favorable meteorological condition tends to occur in the coastal zones in the Pacific side west of Ibaraki and around Kyushu island. The frequency in these zones is different from the one in the other area in the order of 1 or 2, which is large enough for regionalization. (author)

  17. Studies of suprathermal electron loss in the magnetic ripple of Tore Supra

    International Nuclear Information System (INIS)

    Basiuk, V.; Lipa, M.; Martin, G.; Chantant, M.; Guilhem, D.; Imbeaux, F.; Mitteau, R.; Peysson, Y.; Surle, F.

    2000-01-01

    A new prototype of protection against fast electron trapped in the magnetic ripple was installed on Tore-Supra in 1998. It was designed to support the high flux of fast electron generated by lower hybrid in the CIEL project (up to 6 MW/m 2 ) during steady state experiments. So it is actively cooled and allows a direct measurement of the energy lost in the ripple. (author)

  18. Assessment of the Public Health Risks and Impact of a Tornado in Funing, China, 23 June 2016: A Retrospective Analysis.

    Science.gov (United States)

    Wang, Kaiwen; Zhong, Shuang; Wang, Xiaoye; Wang, Zhe; Yang, Lianping; Wang, Qiong; Wang, Suhan; Sheng, Rongrong; Ma, Rui; Lin, Shao; Liu, Wenyu; Zu, Rongqiang; Huang, Cunrui

    2017-10-10

    (1) Background: Tornadoes are one of the deadliest disasters but their health impacts in China are poorly investigated. This study aimed to assess the public health risks and impact of an EF-4 tornado outbreak in Funing, China; (2) Methods: A retrospective analysis on the characteristics of tornado-related deaths and injuries was conducted based on the database from the Funing's Center for Disease Control and Prevention (CDC) and Funing People's Hospital. A change-point time-series analysis of weekly incidence for the period January 2010 to September 2016 was used to identify sensitive infectious diseases to the tornado; (3) Results: The 75 to 84 years old group was at the highest risk of both death (RR = 82.16; 95% CIs = 19.66, 343.33) and injury (RR = 31.80; 95% CI = 17.26, 58.61), and females were at 53% higher risk of death than males (RR = 1.53; 95% CIs = 1.02, 2.29). Of the 337 injuries, 274 injuries (81%) were minor. Most deaths occurred indoors (87%) and the head (74%) was the most frequent site of trauma during the tornado. Five diseases showed downward change-points; (4) Conclusions: The experience of the Funing tornado underscores the relative danger of being indoors during a tornado and is successful in avoiding epidemics post-tornado. Current international safety guidelines need modification when generalized to China.

  19. Assessment of the Public Health Risks and Impact of a Tornado in Funing, China, 23 June 2016: A Retrospective Analysis

    Directory of Open Access Journals (Sweden)

    Kaiwen Wang

    2017-10-01

    Full Text Available (1 Background: Tornadoes are one of the deadliest disasters but their health impacts in China are poorly investigated. This study aimed to assess the public health risks and impact of an EF-4 tornado outbreak in Funing, China; (2 Methods: A retrospective analysis on the characteristics of tornado-related deaths and injuries was conducted based on the database from the Funing’s Center for Disease Control and Prevention (CDC and Funing People’s Hospital. A change-point time-series analysis of weekly incidence for the period January 2010 to September 2016 was used to identify sensitive infectious diseases to the tornado; (3 Results: The 75 to 84 years old group was at the highest risk of both death (RR = 82.16; 95% CIs = 19.66, 343.33 and injury (RR = 31.80; 95% CI = 17.26, 58.61, and females were at 53% higher risk of death than males (RR = 1.53; 95% CIs = 1.02, 2.29. Of the 337 injuries, 274 injuries (81% were minor. Most deaths occurred indoors (87% and the head (74% was the most frequent site of trauma during the tornado. Five diseases showed downward change-points; (4 Conclusions: The experience of the Funing tornado underscores the relative danger of being indoors during a tornado and is successful in avoiding epidemics post-tornado. Current international safety guidelines need modification when generalized to China.

  20. Residential tornado safe room from commodity wood products – impact and wind pressure testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell; C. Adam Senalik; Marshall Begel

    2018-01-01

    A tornado safe room is a shelter designed to provide protection during a tornado and is specifically engineered to resist the high wind pressures and debris impact generated by these high wind events. The required performance criteria of these shelters has been established and is found in the International Code Council Standard for the Design and Construction of Storm...

  1. Tornado detection data reduction and analysis

    Science.gov (United States)

    Davisson, L. D.

    1977-01-01

    Data processing and analysis was provided in support of tornado detection by analysis of radio frequency interference in various frequency bands. Sea state determination data from short pulse radar measurements were also processed and analyzed. A backscatter simulation was implemented to predict radar performance as a function of wind velocity. Computer programs were developed for the various data processing and analysis goals of the effort.

  2. Global energy confinement in TORE SUPRA

    International Nuclear Information System (INIS)

    Hoang, G.T.; Bizarro, J.P.; Genile, B. de; Hutter, Th.; Laurent, L.; Litaudon, X.; Moreau, D.; Peysson, Y.; Tonon, G.; Houtte, D. van

    1992-01-01

    The global energy confinement behaviour of mixed Ohmic/Lower Hybrid driven Tore Supra plasmas has been analysed at various densities. In contradiction with L-mode ITER scaling law, this analysis indicates that the global energy confinement time depends strongly on the plasma density and the isotopic dependence seems not to be observed. The thermal electron energy content of steady-state discharges is in good agreement with the offset linear Rebut-Lallia scaling law. During current ramp experiments, the global energy confinement time was found to depend on the internal self-inductance (li). Improved confinement has been obtained for a steady-state 0.8 MA plasma where the plasma current profile is peaked by LH waves (li ∼1.8). In this case, the global confinement time is found to be about 40% higher than the value predicted by the Rebut-Lallia scaling law. (author) 3 refs., 6 figs

  3. Ventilation systems analysis during tornado conditions. Progress report, January--June 1975

    International Nuclear Information System (INIS)

    Bennett, G.A.; Gregory, W.S.; Smith, P.R.

    1975-11-01

    The principal concern of this investigation is to develop the capability to simulate the dynamic effects of a tornado depressurization on a ventilation system. The basic formulation and solution of the two-zone series model ventilation subsystem is based on lumped parameter component response equations, the isothermal compression of air, and the conservation of mass. Solutions based on these assumptions are also presented for the two-zone series model with natural bypass, the two-zone series model with recirculation, and the natural branching model. A parameter study is presented comparing the effects of changes in system resistance, system capacitance, and variable tornado depressurization rates. The adaptability of the basic formulation to adiabatic compression of air and the addition of duct resistance is examined. A quasi-steady formulation is introduced and preliminary considerations of the importance of inertia are presented. Preliminary conclusions in this area indicate that inertial effects can be neglected. For relatively long ducts slow shock development appears possible. Work on the effect of tornado depressurization rates as related to shock development and on the importance of inertia effects is continuing

  4. From eroded material to dust: An experimental evaluation of the mobilised dust production in Tore Supra

    International Nuclear Information System (INIS)

    Grisolia, C.; Rosanvallon, S.; Loarte, A.; Sharpe, P.; Arnas, C.

    2009-01-01

    In a fusion reactor like ITER, in-vessel materials are subjected to interactions with the plasma. One of the main consequences of these plasma-material interactions is the creation of co-deposited layers especially with Beryllium and Carbon based materials. Due to internal stresses, part of these layers can crack leading to micro particle creation. The purpose of the following paper is to review the tokamak operation processes that lead to the erosion of the bulk material and then to layer creation. The proportion of these layers that are converted into micro particles will be evaluated in the case of Tore Supra experiments. For Tore Supra, this conversion factor (Cd) is close to 7-8% comparable to the current ITER retained value of 10%. In the second part of the papers, diagnostics which can be used to constraint the Cd value are proposed.

  5. Design and manufacture of the large poloidal coils for TORE SUPRA

    International Nuclear Information System (INIS)

    Calmels, C.; Leloup, C.; Rijnoudt, E.; Ane, J.M.; Chassain, P.; Giaccheto, A.

    1984-01-01

    After a short summary of the main features of the TORE SUPRA long pulse Tokamak poloidal field system, the manufacture process of the six larger coils is described. The hollow conductor copper cross section is almost equal to the water channel one so that the coils can withstand more than 30 s pulses at full power. The main difficulties arise from the exceptional size of these one piece coils which are up to 9 meters in diameter. (author)

  6. Plasma rotation study in Tore Supra radio frequency heated plasmas

    International Nuclear Information System (INIS)

    Chouli, Bilal

    2014-01-01

    Toroidal flows are found to improve the performance of the magnetic confinement devices with increase of the plasma stability and confinement. In ITER or future reactors, the torque from NBI should be less important than in present-day tokamaks. Consequently, it is of interest to study other intrinsic mechanisms that can give rise to plasma rotation in order to predict the rotation profile in experiments. Intriguing observations of plasmas rotation have been made in radio frequency (RF) heated plasmas with little or no external momentum injection. Toroidal rotation in both the direction of the plasma current (co-current) and in the opposite direction (counter-current) has been observed depending on the heating schemes and plasma performance. In Tore Supra, most observations in L-mode plasmas have been in the counter-current direction. However, in this thesis, we show that in lower hybrid current drive (LHCD), the core toroidal rotation increment is in co- or counter-current direction depending on the plasma current amplitude. At low plasma current the rotation change is in the co-current direction while at high plasma current, the change is in the counter-current direction. In both low and high plasma current cases, rotation increments are found to increase linearly with the injected LH power. Several mechanisms in competition which can induce co- or counter-current rotation in Tore Supra LHCD plasmas are investigated and typical order of magnitude are discussed in this thesis. (author) [fr

  7. An advanced plasma control system for Tore Supra

    International Nuclear Information System (INIS)

    Wijnands, T.; Martin, G.

    1996-01-01

    First results on plasma control with the new plasma control system of Tore Supra are presented. The system has been especially designed for long pulse operation: plasmas are controlled on reference signals, which can be varied in real time by using diagnostic measurements. On line determination of the global plasma equilibrium has enabled new operation scenarios in which both the power from the poloidal field generators and the total Lower Hybrid (LH) power are used to control the plasma. Experiments with feedback control of the safety factor on the plasma boundary, control of the LH driven current, control of the flux on the plasma boundary and control of the internal inductance are discussed. (author)

  8. An advanced plasma control system for Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Wijnands, T.; Martin, G.

    1996-01-01

    First results on plasma control with the new plasma control system of Tore Supra are presented. The system has been especially designed for long pulse operation: plasmas are controlled on reference signals, which can be varied in real time by using diagnostic measurements. On line determination of the global plasma equilibrium has enabled new operation scenarios in which both the power from the poloidal field generators and the total Lower Hybrid (LH) power are used to control the plasma. Experiments with feedback control of the safety factor on the plasma boundary, control of the LH driven current, control of the flux on the plasma boundary and control of the internal inductance are discussed. (author). 12 refs.

  9. Current diffusion and flux consumption in Tore Supra

    International Nuclear Information System (INIS)

    Van Houtte, D.; Talvard, M.; Agostini, E.; Gil, C.; Hoang, G.T.; Lecoustey, P.; Parlange, F.; Rodriguez, L.; Vallet, J.C.

    1991-01-01

    TORE SUPRA has been designed to study long pulse plasmas (t > 30 s) at high plasma current (Ip < 2 MA) associated with high additional power (20 MW). Current diffusion studies are essentially based on the analysis of the plasma discharge paths. The current diffusion rate during the current rise phase is analysed with a numerical code using plasma resistivity profiles from Te profiles measured by the ECE diagnostic. Owing to the fact that the quantity of magnetic flux available in a tokamak is limited, perfect knowledge is required of the various components of the flux consumed in order to minimize consumption and to be able to define a suitable transformer size for future high current tokamak projects

  10. Identification and real time control of current profile in Tore-supra: algorithms and simulation; Identification et controle en temps reel du profil de courant dans Tore Supra: algorithmes et simulations

    Energy Technology Data Exchange (ETDEWEB)

    Houy, P

    1999-10-15

    The aim of this work is to propose a real-time control of the current profile in order to achieve reproducible operating modes with improved energetic confinement in tokamaks. The determination of the profile is based on measurements given by interferometry and polarimetry diagnostics. Different ways to evaluate and improve the accuracy of these measurements are exposed. The position and the shape of a plasma are controlled by the poloidal system that forces them to cope with standard values. Gas or neutral ions or ice pellet or extra power injection are technical means used to control other plasma parameters. These controls are performed by servo-controlled loops. The poloidal system of Tore-supra is presented. The main obstacle to a reliable determination of the current profile is the fact that slightly different Faraday angles lead to very different profiles. The direct identification method that is exposed in this work, gives the profile that minimizes the square of the margin between measured and computed values. The different algorithms proposed to control current profiles on Tore-supra have been validated by using a plasma simulation. The code Cronos that solves the resistive diffusion equation of current has been used. (A.C.)

  11. Temperature oscillating regimes in Tore Supra diagnosed by MHD activity

    International Nuclear Information System (INIS)

    Maget, P.; Imbeaux, F.; Giruzzi, G.; Udintsev, V.S.; Huysmans, G.T.A.; Segui, J.-L.; Goniche, M.; Moreau, Ph.; Sabot, R.; Garbet, X.

    2006-01-01

    This paper describes what we can learn on the regimes of spontaneous electron temperature oscillations discovered in Tore Supra from the analysis of MHD activity. Since the first observations of this oscillating behaviour of plasma equilibrium, and its interpretation as a predator-prey system involving lower hybrid waves power deposition and electron confinement, analysis of MHD modes has confirmed the reality of safety factor profile oscillations. This points towards the importance of rational values of the safety factor in the transition to transport barriers in reversed magnetic shear plasmas

  12. Full-scale impact test data for tornado-missile design of nuclear plants

    International Nuclear Information System (INIS)

    Stephenson, A.E.; Sliter, G.E.

    1977-01-01

    It is standard practice to consider the effects of low-probability impacts of tornado-borne debris (''tornado missiles'' such as utility poles and steel pipes) in the structural design of nuclear power plants in the United States. To provide data that can be used directly in the design procedure, a series of full-scale tornado-missile impact tests was performed. This paper is a brief summary of the results and conclusions from these tests. The tests consisted of reinforced concrete panels impacted by poles, pipes, and rods propelled by a rocket sled. The panels were constructed to current minimum standards and had thicknesses typical of auxiliary buildings of nuclear power plants. A specific objective was the determination of the impact velocities below which the panels do not experience backface scabbing. Another objective was to assess the adequacy of (1) conventional design formulae for penetration and scabbing and (2) conventional design methods for overall structural response. Test missiles and velocities represented those in current design standards. Missiles included utility poles, steel pipes, and steel bars. It is important to interpret the data in this paper in recognition that the test conditions represent conservative assumptions regarding maximum wind speeds, injection of the missile into the wind stream, aerodynamic trajectory, and orientation of missile at impact. Even with the severe assumptions made, the full-scale tests described demonstrate the ability of prototypical nuclear plant walls and roofs to provide adequate protection against postulated tornado-missile impact

  13. Four hospitals in the path of killer tornadoes--what happened before ... during ... after.

    Science.gov (United States)

    Friedrick, Joanne

    2012-01-01

    In mid-and late-April, late May, and early June of 2011, tornadoes swept across states in the Midwest, South, Southeast, and even New England, killing hundreds, injuring thousands, destroying property in the billions in both rural and urban areas. Some hospitals in areas where the tornadoes struck did not escape damage and one was destroyed. This article describes what happened at four hospitals in cities hardest hit by the storms and the many roles played by security officers.

  14. Using Unmanned Aerial Vehicles (UAVs) to Modeling Tornado Impacts

    Science.gov (United States)

    Wagner, M.; Doe, R. K.

    2017-12-01

    Using Unmanned Aerial Vehicles (UAVs) to assess storm damage is a useful research tool. Benefits include their ability to access remote or impassable areas post-storm, identify unknown damages and assist with more detailed site investigations and rescue efforts. Technological advancement of UAVs mean that they can capture high resolution images often at an affordable price. These images can be used to create 3D environments to better interpret and delineate damages from large areas that would have been difficult in ground surveys. This research presents the results of a rapid response site investigation of the 29 April 2017 Canton, Texas, USA, tornado using low cost UAVs. This was a multiple, high impact tornado event measuring EF4 at maximum. Rural farmland was chosen as a challenging location to test both equipment and methodology. Such locations provide multiple impacts at a variety of scales including structural and vegetation damage and even animal fatalities. The 3D impact models allow for a more comprehensive study prior to clean-up. The results show previously unseen damages and better quantify damage impacts at the local level. 3D digital track swaths were created allowing for a more accurate track width determination. These results demonstrate how effective the use of low cost UAVs can be for rapid response storm damage assessments, the high quality of data they can achieve, and how they can help us better visualize tornado site investigations.

  15. The effects of the April 2011 tornado outbreak on personal preparedness in Jefferson County, Alabama.

    Science.gov (United States)

    McCormick, Lisa C; Pevear, Jesse; Rucks, Andrew C; Ginter, Peter M

    2014-01-01

    The purpose of this study was to examine the effects of a tornado disaster on the personal preparedness of local residents to determine (1) to what extent the tornado outbreak experience had altered preparedness awareness, willingness to act, and levels of personal preparedness of residents as measured by possession of a preparedness kit; and (2) what effect this experience had on the variables associated with having a complete disaster preparedness kit. Two random digit-dialed surveys were completed following the Behavioral Risk Factor Surveillance System protocols. The pre-tornado survey was conducted between October and December 2010 and the post-tornado survey was conducted between January and March 2012. After the April 2011 tornado outbreak, 86.08% of the respondents (n = 1364) reported that they had thought more about personal or family preparedness and 59.65% (n = 907) reported that they had taken actions to increase their level of preparedness. Overall, general awareness of preparedness media campaigns increased significantly (almost 24%; P < .0001), as did the percentage of those having a complete disaster preparedness kit (a 66% increase, not quite doubled from 2010 to 2012; P < .0001). Findings of the study indicate that the disaster had a significant impact on the local residents' (1) awareness of preparedness campaigns, (2) awareness of the need to be prepared, (3) willingness to become better prepared, and (4) possession of a disaster and emergency preparedness kit and its associated items.

  16. The political ecology of disaster: an analysis of factors influencing U.S. tornado fatalities and injuries, 1998-2000.

    Science.gov (United States)

    Donner, William R

    2007-08-01

    This study examines casualties from tornadoes in the United States between the years 1998 and 2000. A political model of human ecology (POET) was used to explore how the environment, technology, and social inequality influence rates of fatalities and injuries in two models. Data were drawn from four sources: John Hart's Severe Plot v2.0, National Weather Service (NWS) Warning Verification data, Storm Prediction Center (SPC) watch data, and tract-level census data. Negative binomial regression was used to analyze the causes of tornado fatalities and injuries. Independent variables (following POET) are classified in the following manner: population, organization, environment, and technology. Rural population, population density, and household size correspond to population; racial minorities and deprivation represent social organization; tornado area represents environment; and tornado watches and warnings, as well as mobile homes, correspond to technology. Findings suggest a strong relationship between the size of a tornado path and both fatalities and injuries, whereas other measures related to technology, population, and organization produce significant yet mixed results. Census tracts having larger populations of rural residents was, of the nonenvironmental factors, the most conclusive regarding its effects across the two models. The outcomes of analysis, although not entirely supportive of the model presented in this study, suggest to some degree that demographic and social factors play a role in vulnerability to tornadoes.

  17. Tornado risk analysis at Savannah River Plant using windspeed damage thresholds and single building strike frequencies

    International Nuclear Information System (INIS)

    Taylor, D.H.; McDonald, J.R.; Twisdale, L.A.

    1985-01-01

    Tornado risk analysis at the Savannah River Plant has taken a two pronged approach: (1) developing a catalogue of damage thresholds as a function of windspeed for processing buildings and other representative site structures; (2) developing a method of estimating, for each building, the probability of a tornado exceeding each damage threshold. Wind resistance of building construction at SRP varies widely depending on the function of the structure. It was recognized that all tornadoes do not necessarily seriously damage buildings, but the damage thresholds were unknown. In order to evaluate the safety of existing structures and properly design new structures, an analysis of tornado resistance was conducted by J.R. McDonald on each process building at SRP and other buildings by type. Damage estimates were catalogued for each Fujita class windspeed interval and windspeeds were catalogued as a function of increased levels of damage. Tornado single point and structure specific strike probabilities for the SRP site were determined by L.A. Twisdale using the TORRISK computer code. To calculate the structure specific strike probability, a correction factor is determined from a set of curves using building area and aspect ratio (length/width relative to north) as parameters. The structure specific probability is then the product of the correction factor and the point probability. The correction factor increases as a function of building size and windspeed. For large buildings (10 5 ft 2 ) and very intense storms (250 mph), the correction factor is equal to or greater than 4. The cumulative probability of a tornado striking any building type (process, personnel, etc.) was also calculated

  18. Ion temperature measurements in the scrape-off layer of the Tore Supra Tokamak

    International Nuclear Information System (INIS)

    Kocan, M.

    2009-10-01

    The thesis describes measurements of the scrape-off layer (SOL) ion temperature T i with a retarding field analyzer (RFA) in the limiter tokamak Tore Supra. Considerable emphasis is placed on study of the instrumental effects of RFAs and their influence on T i measurements. In general, the influence of instrumental effects on T i measurements is found to be relatively small. The instrumental study is followed by systematic measurements of T i (as well as other parameters) in the Tore Supra SOL. This includes the scaling of SOL temperatures and electron density with the main plasma parameters (such as the plasma density, toroidal magnetic field, working gas, and the radiated power fraction). Except at very high densities or in detached plasmas, SOL T i is found to be higher than T e by up to a factor of 7. While SOL T i is found to vary by almost two orders of magnitude, following the variation of the core temperatures, SOL T e changes only little and seems to be decoupled from the core plasma. The first continuous T i /T e profile from the edge of the confined plasma into the SOL is constructed using data from different tokamaks. It is shown that T i /T e > 1 in the SOL but also in the confined plasma, and increases with radius. The first evidence of poloidal asymmetry of the radial ion and electron energy transport in the SOL is reported. Implications for ITER start-up phase are discussed. Correlation of the asymmetries of SOL T i and T e measured from both directions along the magnetic field lines with changes of the parallel Mach number is studied. SOL T i was measured for the first time in Tore Supra by charge exchange recombination spectroscopy (CXRS) and compared to RFA data. A factor of 4 higher T i measured by CXRS is a subject of further analysis. (A.C.)

  19. Okla. Tornado Renews Debate on Storm Safety

    Science.gov (United States)

    Shah, Nirvi

    2013-01-01

    As soon as the winds that left seven students in Moore, Okla., dead last month had calmed, and more storms blew through the same area less than two weeks later, questions about the safety of schools in a region labeled Tornado Alley rose amid the rubble. While better design of new schools and thorough emergency training and practice may be in…

  20. Transport in the plasma edge specific connection to the wall in the Tore Supra ergodic divertor experiments

    International Nuclear Information System (INIS)

    Grosman, A.; Ghendrih, P.; DeMichelis, C.; Monier-Garbet, P.; Vallet, J.C.; Capes, H.; Chatelier, M.; Geraud, A.; Goniche, M.; Grisolia, C.; Guilhem, D.; Harris, G.; Hess, W.; Nguyen, F.; Poutchy, L.; Samain, A.

    1992-01-01

    The ergodic divertor experiments in TORE SUPRA can be analysed along two main lines. The first one refers to the change of the heat and particle transport in the ergodized zone. This is especially true for the electron heat transport which is enhanced in the edge layer. But other distinctive features give evidence of the importance of the parallel connexion length between the plasma edge and the wall. The field lines, which are stochastic in the major part of the perturbed layer (10-15 cm) are such that, in the outermost layer (3 cm), the connexion topology is regular. This has obvious effects on the particle and power deposition, but also on the plasma parameters, and consequently influences the particle recycling and impurity shielding processes. The TORE SUPRA ergodic divertor experiments are reviewed in this framework

  1. Investigation into the Formation, Structure, and Evolution of an EF4 Tornado in East China Using a High-Resolution Numerical Simulation

    Science.gov (United States)

    Yao, Dan; Xue, Haile; Yin, Jinfang; Sun, Jisong; Liang, Xudong; Guo, Jianping

    2018-04-01

    Devastating tornadoes in China have received growing attention in recent years, but little is known about their formation, structure, and evolution on the tornadic scale. Most of these tornadoes develop within the East Asian monsoon regime, in an environment quite different from tornadoes in the U.S. In this study, we used an idealized, highresolution (25-m grid spacing) numerical simulation to investigate the deadly EF4 (Enhanced Fujita scale category 4) tornado that occurred on 23 June 2016 and claimed 99 lives in Yancheng, Jiangsu Province. A tornadic supercell developed in the simulation that had striking similarities to radar observations. The violent tornado in Funing County was reproduced, exceeding EF4 (74 m s-1), consistent with the on-site damage survey. It was accompanied by a funnel cloud that extended to the surface, and exhibited a double-helix vorticity structure. The signal of tornado genesis was found first at the cloud base in the pressure perturbation field, and then developed both upward and downward in terms of maximum vertical velocity overlapping with the intense vertical vorticity centers. The tornado's demise was found to accompany strong downdrafts overlapping with the intense vorticity centers. One of the interesting findings of this work is that a violent surface vortex was able to be generated and maintained, even though the simulation employed a free-slip lower boundary condition. The success of this simulation, despite using an idealized numerical approach, provides a means to investigate more historical tornadoes in China.

  2. Development of a design basis tornado and structural design criteria for Lawrence Livermore Laboratory's Site 300

    International Nuclear Information System (INIS)

    McDonald, J.R.; Minor, J.E.; Mehta, K.C.

    1975-11-01

    Criteria are prescribed and guidance is provided for professional personnel who are involved with the evaluation of existing buildings and facilities at Site 300 near Livermore, California to resist the possible effects of extreme winds and tornadoes. The development of parameters for the effects of tornadoes and extreme winds and guidelines for evaluation and design of structures are presented. The investigations conducted are summarized and the techniques used for arriving at the combined tornado and extreme wind risk model are discussed. The guidelines for structural design methods for calculating pressure distributions on walls and roofs of structures and methods for accommodating impact loads from missiles are also presented

  3. Parametric dependences of impurity transport in the Tore Supra tokamak

    International Nuclear Information System (INIS)

    Parisot, Th.

    2007-09-01

    During this Ph.D. work, a full setup of tools for an experimental investigation of impurity transport has been developed on the Tore Supra tokamak. It includes a laser blow-off system for metallic impurity injections and developments for ITC (Impurity Transport Code), a transport code which allows the extraction of the experimental impurity transport coefficients (diffusion and convection velocity). This tool has been used to perform and analyse several experiments, to evidence parametric dependences of impurity transport. In a first experiment, a confinement time law for nickel in Tore Supra has been obtained as a function of collisionality ν * and normalized Larmor radius ρ * . Then the impurity charge Z role has been investigated in various conditions: ohmic regime with or without sawteeth, and sawtooth less L-mode with LH power. No Z effect is observed, consistently with theoretical predictions, whether neoclassical (NCLASS) or for turbulent transport with both non linear gyro-fluid (TRB) and quasilinear gyrokinetic (QuaLiKiz) simulations. An exception is found for LH heated plasmas where the confinement time seems to decrease for the heaviest impurities. This is not explained by any model available. The observed transport is close to neoclassical between sawtooth relaxations, in the centre (r q-1 ) of ohmic plasmas, turbulent outside. Without sawteeth, it is turbulent in the whole plasma, for ohmic or L mode discharges. The profile shape of the diffusion coefficient is here qualitatively different, with a stronger and deeper transition between the low diffusion central region and a more turbulent peripheral region for LH heated plasmas. (author)

  4. Tornado missile simulation and design methodology. Volume 1: simulation methodology, design applications, and TORMIS computer code. Final report

    International Nuclear Information System (INIS)

    Twisdale, L.A.; Dunn, W.L.

    1981-08-01

    A probabilistic methodology has been developed to predict the probabilities of tornado-propelled missiles impacting and damaging nuclear power plant structures. Mathematical models of each event in the tornado missile hazard have been developed and sequenced to form an integrated, time-history simulation methodology. The models are data based where feasible. The data include documented records of tornado occurrence, field observations of missile transport, results of wind tunnel experiments, and missile impact tests. Probabilistic Monte Carlo techniques are used to estimate the risk probabilities. The methodology has been encoded in the TORMIS computer code to facilitate numerical analysis and plant-specific tornado missile probability assessments. Sensitivity analyses have been performed on both the individual models and the integrated methodology, and risk has been assessed for a hypothetical nuclear power plant design case study

  5. Emotional Reactions of Rescue Workers Following a Tornado.

    Science.gov (United States)

    McCammon, Susan L.; And Others

    Rescue and medical workers may be at risk for negative emotional experience following intervention efforts in disaster situations. To examine this possibility, 120 rescue and hospital personnel responded to a survey of their emotional reactions and coping behaviors 3 months after a devastating tornado. Twenty-eight subjects had been involved in…

  6. The ground fault detection system for the Tore Supra toroidal pump limiter

    International Nuclear Information System (INIS)

    Zunino, K.; Cara, P.; Fejoz, P.; Hourtoule, J.; Loarer, T.; Pomaro, N.; Santagiustina, A.; Spuig, P.; Villecroze, F.

    2003-01-01

    The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding

  7. The response of the Tore Supra edge plasma to supersonic pulsed gas injection

    Czech Academy of Sciences Publication Activity Database

    Pánek, Radomír; Gunn, J. P.; Bucalossi, J.; Ďuran, Ivan; Geraud, A.; Hron, Martin; Loarer, T.; Pégourié, B.; Stöckel, Jan; Tsitrone, E.

    337-339, č. 16 (2005), s. 530-534 ISSN 0022-3115. [Plasma Surface Interactions /16./. Portland, 24.5.2005-28.5.2005] R&D Projects: GA ČR(CZ) GP202/03/P062 Institutional research plan: CEZ:AV0Z20430508 Keywords : Edge plasma * Gas injection and fuelling * probes * Plasma flow * Tore Supra Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.414, year: 2005

  8. Necrotizing cutaneous mucormycosis after a tornado in Joplin, Missouri, in 2011.

    Science.gov (United States)

    Neblett Fanfair, Robyn; Benedict, Kaitlin; Bos, John; Bennett, Sarah D; Lo, Yi-Chun; Adebanjo, Tolu; Etienne, Kizee; Deak, Eszter; Derado, Gordana; Shieh, Wun-Ju; Drew, Clifton; Zaki, Sherif; Sugerman, David; Gade, Lalitha; Thompson, Elizabeth H; Sutton, Deanna A; Engelthaler, David M; Schupp, James M; Brandt, Mary E; Harris, Julie R; Lockhart, Shawn R; Turabelidze, George; Park, Benjamin J

    2012-12-06

    Mucormycosis is a fungal infection caused by environmentally acquired molds. We investigated a cluster of cases of cutaneous mucormycosis among persons injured during the May 22, 2011, tornado in Joplin, Missouri. We defined a case as a soft-tissue infection in a person injured during the tornado, with evidence of a mucormycete on culture or immunohistochemical testing plus DNA sequencing. We conducted a case-control study by reviewing medical records and conducting interviews with case patients and hospitalized controls. DNA sequencing and whole-genome sequencing were performed on clinical specimens to identify species and assess strain-level differences, respectively. A total of 13 case patients were identified, 5 of whom (38%) died. The patients had a median of 5 wounds (range, 1 to 7); 11 patients (85%) had at least one fracture, 9 (69%) had blunt trauma, and 5 (38%) had penetrating trauma. All case patients had been located in the zone that sustained the most severe damage during the tornado. On multivariate analysis, infection was associated with penetrating trauma (adjusted odds ratio for case patients vs. controls, 8.8; 95% confidence interval [CI], 1.1 to 69.2) and an increased number of wounds (adjusted odds ratio, 2.0 for each additional wound; 95% CI, 1.2 to 3.2). Sequencing of the D1-D2 region of the 28S ribosomal DNA yielded Apophysomyces trapeziformis in all 13 case patients. Whole-genome sequencing showed that the apophysomyces isolates were four separate strains. We report a cluster of cases of cutaneous mucormycosis among Joplin tornado survivors that were associated with substantial morbidity and mortality. Increased awareness of fungi as a cause of necrotizing soft-tissue infections after a natural disaster is warranted.

  9. Unmanned Aerial Vehicle Systems for Disaster Relief: Tornado Alley

    Science.gov (United States)

    DeBusk, Wesley M.

    2009-01-01

    Unmanned aerial vehicle systems are currently in limited use for public service missions worldwide. Development of civil unmanned technology in the United States currently lags behind military unmanned technology development in part because of unresolved regulatory and technological issues. Civil unmanned aerial vehicle systems have potential to augment disaster relief and emergency response efforts. Optimal design of aerial systems for such applications will lead to unmanned vehicles which provide maximum potentiality for relief and emergency response while accounting for public safety concerns and regulatory requirements. A case study is presented that demonstrates application of a civil unmanned system to a disaster relief mission with the intent on saving lives. The concept utilizes unmanned aircraft to obtain advanced warning and damage assessments for tornados and severe thunderstorms. Overview of a tornado watch mission architecture as well as commentary on risk, cost, need for, and design tradeoffs for unmanned aerial systems are provided.

  10. Using Satellite Imagery to Identify Tornado Damage Tracks and Recovery from the April 27, 2011 Severe Weather Outbreak

    Science.gov (United States)

    Cole, Tony A.; Molthan, Andrew L.; Bell, Jordan R.

    2014-01-01

    Emergency response to natural disasters requires coordination between multiple local, state, and federal agencies. Single, relatively weak tornado events may require comparatively simple response efforts; but larger "outbreak" events with multiple strong, long-track tornadoes can benefit from additional tools to help expedite these efforts. Meteorologists from NOAA's National Weather Service conduct field surveys to map tornado tracks, assess damage, and determine the tornado intensity following each event. Moderate and high resolution satellite imagery can support these surveys by providing a high-level view of the affected areas. Satellite imagery could then be used to target areas for immediate survey or to corroborate the results of the survey after it is completed. In this study, the feasibility of using satellite imagery to identify tornado damage tracks was determined by comparing the characteristics of tracks observed from low-earth orbit to tracks assessed during the official NWS storm survey process. Of the 68 NWS confirmed centerlines, 24 tracks (35.3%) could be distinguished from other surface features using satellite imagery. Within each EF category, 0% of EF-0, 3% of EF-1, 50% of EF-2, 77.7% of EF-3, 87.5% of EF-4 and 100% of EF-5 tornadoes were detected. It was shown that satellite data can be used to identify tornado damage tracks in MODIS and ASTER NDVI imagery, where damage to vegetation creates a sharp drop in values though the minimum EF-category which can be detected is dependent upon the type of sensor used and underlying vegetation. Near-real time data from moderate resolution sensors compare favorably to field surveys after the event and suggest that the data can provide some value in the assessment process.

  11. Alabama Disasters: Leveraging NASA EOS to Explore the Environmental and Economic Impact of the April 27 Tornado Outbreak

    Science.gov (United States)

    Herdy, Claire; Luvall, Jeff

    2012-01-01

    The disastrous tornado outbreak in Alabama on April 27, 2011 greatly impacted the economy of the state. On record, the tornado outbreak was the second deadliest tornado outbreak in U.S. When considering the agricultural and value-added activities such as food and timber processing, farm inputs, manufacturing, transportation, and retail sales, the dollar value of Alabama agribusiness annually exceeds $40 billion (NASS, 2011). This research aims to examine how the timber and agriculture damage affected the state economy of Alabama and will be used to aid in long-term economic recovery. ASTER imagery was used along with ground-truthed NASS (National Agriculture Statistics Service) crop location records to verify the economic impact tornadoes had on the agricultural economy of the state. This swath damage can be calculated by correlating tornado path with NASS statistics on crop yield, precisely showing the fields affected and dollars lost to this disaster. Not only can this be executed manually using ENVI and ArcGIS, but also through the use of Python, a programming language that has the ability to automate the process, creating a product for initial damage assessment.

  12. 77 FR 4389 - In the Matter of Tornado Gold International Corp., Twin Faces East Entertainment Corp., Universal...

    Science.gov (United States)

    2012-01-27

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of Tornado Gold International Corp., Twin Faces East Entertainment Corp., Universal Ice Blast, Inc., US Farms, Inc., US Microbics... concerning the securities of Tornado Gold International Corp. because it has not filed any periodic reports...

  13. Development of a tornado safe room door from wood Products: door design and impact testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell

    2016-01-01

    In this study, a tornado safe room door built from wood products and steel sheeting was developed and impact-tested according to tornado safe room standards. Results indicate that an door constructed from as few as two sheets of 23/32-in. (18.26-mm) construction-grade plywood and overlaid with 18-gauge (0.05-in.- (1.27- mm-) thick) steel can pass the required impact...

  14. Full-scale Tornado-missile impact tests

    International Nuclear Information System (INIS)

    1976-04-01

    Initial tests with four types of hypothetical tornado-borne missiles impacting reinforced concrete panels have been completed. Panel thicknesses are typical of walls in nuclear power facilities. In the seven tests, the missiles were rocket propelled to velocities currently postulated as being attainable by debris in tornadoes. The objective of the 18-test program is to ascertain the vulnerability of test panels to penetration and backface scabbing. The four missile types being tested are: a 1500-pound 35-foot long utility pole, an 8-pound 1-inch Grade 60 reinforcing bar, a 78-pound 3-inch Schedule 40 pipe, and a 743-pound 12-inch Schedule 40 pipe. The test panels are 12, 18, and 24 inches thick with 15 by 15 foot free spans. They were constructed to current minimum ACI standards: 3000 psi design strength (actual strength about 3600 psi) and 0.2 percent reinforcing steel area each way, each face (actual area is about 0.27 percent with bars on 12-inch centers). The 12-inch pipe has been identified as the critical missile for design of nuclear facility walls under currently specified impact conditions. The utility poles splintered upon impact causing virtually no impact damage, and the 3-inch pipe and 1-inch rebar were comparatively ineffectual because of their light weight

  15. Power deposition profile during lower hybrid current drive in Tore Supra

    International Nuclear Information System (INIS)

    Pecquet, A.L.; Moreau, D.; Fall, T.; Lasalle, J.; Lecoustey, P.; Mattioli, M.; Peysson, Y.; Auge, N.; Rodriguez, L.; Talvard, M.; Hubbard, A.; Moret, J.M.

    1991-01-01

    Lower hybrid current drive (LHCD) experiments have been performed in Tore Supra in various density regimes. The total power coupled to the plasma reached 4MW and a strong electron heating has been observed. To investigate the power deposition mechanism on the electrons, r.f power modulation experiments have been performed. These experiments allow us to estimate the power deposition profiles on both thermal and non-thermal electrons and also to study their respective time responses. From these studies it is possible to deduce a thermal heating scenario which agrees with the experimental results

  16. Depletion of hydrogenoid atoms from the carbonized layer in Tore Supra

    International Nuclear Information System (INIS)

    Crisolia, C.; Grosman, A.; Bardon, J.

    1992-01-01

    The wall production of deuterium and hydrogen during an helium glow discharge of 1.6x10 5 s has been studied after 100 deuterium plasma shots in Tore Supra. After a transient, the desorption followed a t -1 time behaviour for the deuterium a t -1/2 behaviour for the hydrogen. The results are discussed in terms of ion-induced release for the deuterium and a diffusion-limited mechanism for the hydrogen. The values obtained for the different parameters are in good agreement with the relevant data of the literature. (orig.)

  17. Mechanical stress analysis for the poloidal field coils of TORE SUPRA

    International Nuclear Information System (INIS)

    Ane, J.M.; Perin, J.P.

    1985-01-01

    Hoop stresses, up to 100 MPa, in the poloidal field coils of TORE SUPRA have to be reacted back to the main body of the coil where a conductor ends or is twisted for an interturn or an interlayer transition. The load is taken by shear stress through the insulation. Carefully designed configurations, based on 1D, 2D and 3D analysis results, limit the shear stress levels to 15 MPa. A fatigue test of a conductor termination has shown that the experimental results are in good agreement with the calculated stresses

  18. Scientific feedback from high heat flux actively cooled PFCs development, realization and first results in Tore Supra

    International Nuclear Information System (INIS)

    Grosman, A.; Bayetti, P.; Brosset, C.; Bucalossi, J.; Cordier, J.J.; Durocher, A.; Escourbiac, F.; Ghendrih, Ph.; Guilhem, D.; Gunn, J.; Loarer, T.; Lipa, M.; Mitteau, R.; Pegourie, B.; Reichle, R.; Schlosser, J.; Tsitrone, E.; Vallet, J.C.

    2004-01-01

    The implementation of actively cooled high heat flux plasma facing components (PFCs) are one of the major ingredients required for operating the Tore Supra tokamak with very long pulses. A pioneering activity has been developed in this field from the very beginning of the device operation that is today culminating with the routine operation of an actively cooled toroidal pumped limiter (TPL) capable to sustain up to 10 MW.m -2 of nominal convected heat flux. A technical feedback is given from the whole development up to the industrialization and focuses on a number of critical issues, such as bonding technology analysis, manufacture processes, repair processes, destructive and non destructive testing. The actual experience in Tore Supra allows to address the question of D retention on carbon walls. Redeposition on surfaces without plasma flux is suspected to cause the final 'burial' of about the injected gas during long discharges. (authors)

  19. First pump limiter experiments in Tore Supra

    International Nuclear Information System (INIS)

    Chatelier, M.; Bruneau, J.L.; Chappuis, P.; Gil, C.; Guilhem, D.; Lipa, M.; Rodriguez, L.; Vallet, J.C.; Van Houtte, D.; Watkins, J.G.

    1989-01-01

    The thermal load and the particle pumping effects on the outboard pump limiters (OPL), in Tore Supra are analyzed. The investigations are performed for the plasma either in contact with the OPL/ONPL (outboard non pumped limiters) alone or with the OPL and the vertical limiters together. Calorimetric measurements provide estimates of the time-integrated balance of the energy flow at the plasma edge. Radiated and charge exchange energy losses are deduced from the inner vessel calorimetry (R=242cm, a=94cm). Conductive/convective losses on the OPL and vertical (top and bottom) limiters are independently measured, as well as the integrated energy flow on the ergodic divertors. The calorimetric results, the bolometric measurements of the radiated power and the Ohmic power estimates, are indicated. The central line density from interferometric measurement for the two successive shots, with the ONPL and with the OPL, are given

  20. First ECRH modulation experiments in Tore Supra

    International Nuclear Information System (INIS)

    Zou, X.L.; Artaud, J. F.; Bouquey, F.; Clary, J.; Darbos, C.; Giruzzi, G.; Lennholm, M.; Magne, R.; Segui, J.L.

    2003-01-01

    The modulation of Electron Cyclotron Resonance Heating (ECRH) is a powerful tool to investigate the crucial problem of heat transport in tokamaks. This method consists in producing perturbations in the electron temperature by means of highly localised electron heating. By studying the propagation of the heat pulse associated with such perturbations, it is possible to determine both the heat transport coefficient and, as a by-product, the ECRH power deposition. In this work, three methods have been used for electron transport analysis: i) the well-known FFT method; ii) an analytical method, consisting in the simulation of the temperature modulation by an analytical solution of the heat transport equation in cylindrical geometry; iii) the power balance method with the profile analysis. The three methods are applied to the analysis of recent experiments performed on Tore Supra, and their advantages and drawbacks are discussed. (authors)

  1. Systematic Study of the Failure of a Light-Frame Wood Roof in a Tornado

    OpenAIRE

    Lindt, John van de; Amini, Mohammad; Standohar-Alfano, Christine; Dao, Thang

    2012-01-01

    Tornadoes are a particularly devastating natural hazard that affect communities across the United States, particularly the Midwest and South. They are unique from an engineering point-of-view due to their very low probability of occurrence but often highly destructive consequences. The 2011 season was particularly devastating to the Southeastern portion of the U.S. This paper presents a single case study of a 2012 tornado that struck a single large rural light-frame wood house with an unconve...

  2. Full-scale tornado-missile impact tests

    International Nuclear Information System (INIS)

    Stephenson, A.E.; Sliter, G.E.; Burdette, E.G.

    1978-01-01

    Full-scale poles, pipes, and rods, representing postulated tornado-borne missiles, were rocket-propelled into reinforced concrete panels with thicknesses typical of walls and roofs in the auxillary buildings of nuclear power plants. Data from the 18 tests can be used directly for structural design or for validating design and analysis techniques. The test panels, constructed with 3000-psi design strength concrete and minimum allowable reinforcement, were 12, 18 and 24 in. thick with 15 X 15-ft unsupported spans. (Auth.)

  3. On the role of ion heating in ICRF-heated discharges in Tore Supra

    International Nuclear Information System (INIS)

    Eriksson, L.G.; Hoang, G.; Bergeaud, V.

    2000-09-01

    The effect of bulk ion heating in Tore Supra has been investigated by studying discharges with varying concentrations of minority ions during ICRF hydrogen minority heating in Deuterium/ 4 He plasmas. As expected, the level of bulk ion heating is found to increase with the minority concentration. Higher levels of ion heating are shown to be accompanied by two significant effects: an improved energy confinement and a strong influence on the plasma rotation. (author)

  4. Ground beetle (Coleoptera, Carabidae) assemblages inhabiting Scots pine stands of Puszcza Piska Forest: six-year responses to a tornado impact.

    Science.gov (United States)

    Skłodowski, Jarosław; Garbalińska, Paulina

    2011-01-01

    Ground beetle assemblages were studied during 2003-08 in the Pisz Forest by comparing stands disturbed by a tornado to undisturbed control stands. The following exploratory questions were put forward. (1) How do the carabid assemblages change during six years following the tornado impact? (2) Does the carabid assemblage recovery begin during the six first post-tornado years? To assess the state of carabid assemblages we used two indices: the MIB (Mean Individual Biomass) and the SPC (Sum of Progressive Characteristics). Carabid assemblages in the disturbed and in the control stands, as expressed by these two indices, were compared using the length of a regression distance (sample distance in a MIB:SPC coordinate system). A cluster analysis revealed that the assemblages of the disturbed and the control stands were different. The tornado-impacted stands produced lower carabid catch rates, but species richness was significantly higher there than in the control stands. They hosted lower proportions of individuals of European species, of large zoophages, and of forest and brachypterous species, than the control stands. The observed reduction in SPC and MIB, and an increase in the regression distances may indicate that the carabid assemblages had not started to recover from the tornado-caused disturbance. Carabid assemblages apparently responded to the tornado in two steps. Firstly, the first three years were characterized by moderate decreases of index values. Secondly, from the fourth to the sixth year after the tornado, many observed changes became magnified. We did not observe clear signals of the recovery of forest carabid assemblages during the six follow-up years.

  5. Mental Health Among Adolescents Exposed to a Tornado: The Influence of Social Support and Its Interactions With Sociodemographic Characteristics and Disaster Exposure.

    Science.gov (United States)

    Paul, Lisa A; Felton, Julia W; Adams, Zachary W; Welsh, Kyleen; Miller, Stephanie; Ruggiero, Kenneth J

    2015-06-01

    Approximately 25% of youths experience a natural disaster and many experience disaster-related distress, including symptoms of posttraumatic stress disorder (PTSD) and depression. This study contributes to the literature by examining PTSD and depressive symptoms among 2,000 adolescents (50.9% female, 70.5% White) assessed after exposure to tornadoes in 2011. The authors hypothesized that greater tornado exposure, female sex, and younger age would be associated with distress, and that social support would interact with these associations. Analyses showed that PTSD symptoms were associated with lower levels of social support (β = -.28, p tornado exposure (β = .14, p tornado exposure, sex, and social support (β = -.06, p = .017). For boys, the influence of tornado exposure on PTSD symptoms increased as social support decreased. Regardless of level of tornado exposure, low social support was related to PTSD symptoms for girls; depressive symptom results were similar. These findings were generally consistent with the literature and provide guidance for intervention development focused on strengthening social support at the individual, family, and community levels. © 2015 International Society for Traumatic Stress Studies.

  6. Tornado type closed magnetic trap for an ECR source

    CERN Document Server

    Abramova, K B; Voronin, A V; Zorin, V G

    1999-01-01

    We propose to use a Tornado type closed magnetic trap for creation of a source of mul-ticharged ions with plasma heating by microwave radiation. Plasma loss in closed traps is deter-mined by diffusion across the magnetic field, which increases substantially plasma confinement time as compared to the classical mirror trap [1]. We propose to extract ions with the aid of additional coils which partially destroy the closed structure of the magnetic lines in the trap, but don not influence the total confinement time. This allows for producing a controlled plasma flux that depends on the magnetic field of the additional coil. The Tornado trap also possesses merits such as an opportunity to produce high magnetic fields up to 3 T, which makes possible heating and confinement of plasma with a high density of electrons; plasma stability to magneto-hydrodynamic perturbations because the magnetic field structure corresponds to the "min B" configuration; and relatively low costs. All estimates and calculations were carrie...

  7. Innovative probabilistic risk assessment applications: barrier impairments and fracture toughness. 2. Demolition Debris and Tornado Missile Hazard During Decommissioning

    International Nuclear Information System (INIS)

    Calhoun, David; Shepherd, Stephen

    2001-01-01

    During their operating lives, nuclear power plants typically maintain a high level of control over the amount of debris that is allowed to accumulate at the plant site. Although primarily intended to reduce the potential for fire damage, some plants also rely on these controls to limit the damage that could be caused during a tornado from missiles generated from loose debris. Demolition work associated with power plant decommissioning inevitably increases the quantity of debris. When bulk commodities such as piping and electrical distribution components are demolished, they are subject to various staging, handling, and storage processes before they can be released from the site. The demolition of plant structures dramatically increases the quantity of loose steel and concrete debris. For the foreseeable future, all plants that undertake decommissioning will have spent-fuel assemblies present on the plant site during the demolition project whether the spent fuel remains stored in a spent-fuel pool or is transferred to an independent spent-fuel storage installation (ISFSI). Under present regulations, protection from tornado missiles would be required for both types of spent-fuel storage. In addition, a small proportion of decommissioning plants will have operating units in close proximity. Licensing commitments for tornado missile protection may mandate controls on the production or storage of demolition debris. This paper presents a case study of the San Onofre Nuclear Generating Station (Fig. 1). Tornado missile protection licensing commitments from three types of facilities will be in force during the decommissioning of San Onofre Unit 1 (Unit 1): 1. Unit 1, under a possession-only license; 2. an ISFSI that will eventually store spent fuel from Unit 1; 3. San Onofre Operating Unit 2 (Unit 2) and San Onofre Operating Unit 3 (Unit 3). Together, these three facilities illustrate the range of impacts that licensing commitments designed for tornado protection may

  8. Coupling of ionosphere and troposphere during the occurrence of isolated tornadoes on November 20, 1973

    Science.gov (United States)

    Hung, R. J.; Phan, T.; Smith, R. E.

    1979-01-01

    The paper examines the coupling between the ionosphere and the troposphere during time periods with isolated tornadoes on the stormy day of November 20, 1973. Observations are made with a high-frequency CW Doppler array system, in which radio receivers located at a central site monitored signals transmitted from three independent remote sites on three sets of frequencies (4.0125, 4.759, 5.734 MHz) and reflected off the ionosphere approximately halfway between the transmitter and receiver sites. It is shown that the sources of the gravity waves associated with tornadoes are always on the squall lines and near the tornado touchdown locations, and that analyses of ionospheric Doppler sounder observations of medium-scale gravity waves can contribute to the understanding of the coupling between the ionosphere and the troposphere during periods of severe storm activity.

  9. Scientific feedback from high heat flux actively cooled PFCs development, realization and first results in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Grosman, A.; Bayetti, P.; Brosset, C.; Bucalossi, J.; Cordier, J.J.; Durocher, A.; Escourbiac, F.; Ghendrih, Ph.; Guilhem, D.; Gunn, J.; Loarer, T.; Lipa, M.; Mitteau, R.; Pegourie, B.; Reichle, R.; Schlosser, J.; Tsitrone, E.; Vallet, J.C

    2004-07-01

    The implementation of actively cooled high heat flux plasma facing components (PFCs) are one of the major ingredients required for operating the Tore Supra tokamak with very long pulses. A pioneering activity has been developed in this field from the very beginning of the device operation that is today culminating with the routine operation of an actively cooled toroidal pumped limiter (TPL) capable to sustain up to 10 MW.m{sup -2} of nominal convected heat flux. A technical feedback is given from the whole development up to the industrialization and focuses on a number of critical issues, such as bonding technology analysis, manufacture processes, repair processes, destructive and non destructive testing. The actual experience in Tore Supra allows to address the question of D retention on carbon walls. Redeposition on surfaces without plasma flux is suspected to cause the final 'burial' of about the injected gas during long discharges. (authors)

  10. Gas puff modulation experiments in Tore Supra

    International Nuclear Information System (INIS)

    Haas, J.C.M. de; Devynck, P.; Dudok de Wit, T.; Garbet, X.; Gil, C.; Harris, G.; Laviron, C.; Martin, G.

    1993-01-01

    Experiments with a modulation of the gas puff have been done in Tore Supra with the aim to investigate the transport of particles and heat. The target plasma is ohmically heated, sawtoothing with frequencies between 12 and 20 Hz, deuterium for both the plasma and the injection, and with various densities, rising in a series of shots. Both the diffusion coefficient and the pinch velocity for the particle transport were determined using an harmonic modulation. The method gives reasonable results, even for small perturbations, and the obtained values are able to reproduce the stationary values. The heat flow carried by electrons also shows a modulation. The part of the modulation which is not caused by the density can in principle be used to discriminate diffusive and convective terms in the heat flux. An ion temperature profile calculated with empirically determined value of heat diffusivity reproduces the slow evolution of the total kinetic energy. 6 figs., 7 refs

  11. Tornadoes, Florida's Miami Tequesta Site, Memphremagog, America's Stonehenge, A.S., Mexico/Rumford ME, and Some Applied Physics.

    Science.gov (United States)

    Mc Leod, Edward M.; Mc Leod, David M.; Mc Leod, Roger D.

    2002-04-01

    Hay or dust devils, firestorm "twisters", waterspouts, and Fujita's entire range of F1 to F5 tornadoes have a completely explainable common source. These can exist only where the earth's electromagnetic field, EMF, makes loops, or their associated breaks and reorganizations, like those observable at sunspots. Fujita's F1 tornadoes require ionized air in modest thunderclouds with ordinary up- or downdrafts. The equivalent charge-velocity vector then is in "cross-product" with the "hypothesized," but detectable, "tubes" of magnetic field. This creates the familiar vortex that the ionic flow forms, which initially emerges somewhat horizontally from the thundercloud; this can work its way down the loop to touchdown. Fujita's F2 and F3 tornadoes may need the intersection of an ionized jet stream with a high-level EMF loop. The F4 and F5 variety possibly require the combined effects of vertical storm drafts and a jet stream to reach rotational speeds of 318 mph. We have been at EMF sites detectable by blue-light phenomena, A.S. and tornado sites visually qualify.

  12. Measurements of scrape-off layer ion-to-electron temperature ratio in Tore Supra ohmic plasmas

    Czech Academy of Sciences Publication Activity Database

    Kočan, M.; Gunn, J. P.; Pascal, J.-Y.; Bonhomme, G.; Devynck, P.; Ďuran, Ivan; Gauthier, E.; Ghendrih, P.; Marandet, Y.; Pegourie, B.; Vallet, J.-C.

    390-391, - (2009), s. 1074-1077 ISSN 0022-3115. [International Conference on Plasma-Surface Interactions in Controlled Fusion Devices/18th./. Toledo, 26.05.2008-30.05. 2008] Institutional research plan: CEZ:AV0Z20430508 Keywords : Ion temperature * Electron temperature * Edge plasma * Tore Supra Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.933, year: 2009

  13. ITER-like PAM launcher for tore supra's LHCD system

    International Nuclear Information System (INIS)

    Belo, J.H.; Bibet, Ph.; Missirlian, M.; Achard, J.; Beaumont, B.; Bertrand, B.; Chantant, M.; Chappuis, Ph.; Doceul, L.; Durocher, A.; Gargiulo, L.; Saille, A.; Samaille, F.; Villedieu, E.

    2004-01-01

    A new launcher based upon the PAM concept (Passive-Active Multijunction) already proposed for ITER has been developed and is currently under realisation at Tore Supra. It was designed for an injection power capability of 2.7 MW CW at 3.7 GHz, a power density of 25 MW/m 2 , to radiate a power spectrum peaked at N || = 1.7 with a maximum power directivity near the electron cut-off density and with very good coupling properties on a wide range of electron densities. In this paper an overall description of the antenna as well as the foreseen manufacturing and assembling processes are given, followed by the results from studies and optimizations of its RF components, and by a stress analysis of its thermomechanical behaviour. (authors)

  14. Conditional probability of the tornado missile impact given a tornado occurrence

    International Nuclear Information System (INIS)

    Goodman, J.; Koch, J.E.

    1982-01-01

    Using an approach based on statistical mechanics, an expression for the probability of the first missile strike is developed. The expression depends on two generic parameters (injection probability eta(F) and height distribution psi(Z,F)), which are developed in this study, and one plant specific parameter (number of potential missiles N/sub p/). The expression for the joint probability of simultaneous impact of muitiple targets is also developed. This espression is applicable to calculation of the probability of common cause failure due to tornado missiles. It is shown that the probability of the first missile strike can be determined using a uniform missile distribution model. It is also shown that the conditional probability of the second strike, given the first, is underestimated by the uniform model. The probability of the second strike is greatly increased if the missiles are in clusters large enough to cover both targets

  15. ICRF plasma production in Tore Supra: analysis of antenna coupling and plasma properties

    International Nuclear Information System (INIS)

    Beaumont, B.; Becoulet, A.; Lyssoivan, A.

    1999-01-01

    A study of RF plasma production frequency range ω. 2ω ci has been undertaken on Tore Supra taking into account antenna coupling predictions of theory and the TEXTOR-94 database. Two scenarios for RF discharges have been tested (fixed frequency of the RF generator): operation with pure toroidal magnetic field, at standard and lower B T and operation in the magnetic configuration with a small vertical (B V ) field superimposed on B T (B V T ). (authors)

  16. High heat flux actively cooled plasma facing components development, realization and first results in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Grosman, A. [Association Euratom-CEA, Centre d' Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    2004-07-01

    The development, design, manufacture and testing of actively cooled high heat flux plasma facing components (PFC) has been an essential stage towards long powerful tokamak operations for Tore-Supra, it lasted about 10 years. This paper deals with the toroidal pumped limiter (TPL) that is able to sustain up to 10 MW/m{sup 2} of nominal heat flux. This device is based on hardened copper alloy heat sink structures covered by a carbon fiber composite armour, it resulted in the manufacturing of 600 elementary components, called finger elements, to achieve the 7.6 m{sup 2} TPL. This assembly has been operating in Tore-Supra since spring 2002. Some difficulties occurred during the manufacturing phase, the valuable industrial experience is summarized in the section 2. The permanent monitoring of PFC surface temperature all along the discharge is performed by a set of 6 actively cooled infrared endoscopes. The heat flux monitoring and control issue but also the progress made in our understanding of the deuterium retention in long discharges are described in the section 3. (A.C.)

  17. High heat flux actively cooled plasma facing components development, realization and first results in Tore Supra

    International Nuclear Information System (INIS)

    Grosman, A.

    2004-01-01

    The development, design, manufacture and testing of actively cooled high heat flux plasma facing components (PFC) has been an essential stage towards long powerful tokamak operations for Tore-Supra, it lasted about 10 years. This paper deals with the toroidal pumped limiter (TPL) that is able to sustain up to 10 MW/m 2 of nominal heat flux. This device is based on hardened copper alloy heat sink structures covered by a carbon fiber composite armour, it resulted in the manufacturing of 600 elementary components, called finger elements, to achieve the 7.6 m 2 TPL. This assembly has been operating in Tore-Supra since spring 2002. Some difficulties occurred during the manufacturing phase, the valuable industrial experience is summarized in the section 2. The permanent monitoring of PFC surface temperature all along the discharge is performed by a set of 6 actively cooled infrared endoscopes. The heat flux monitoring and control issue but also the progress made in our understanding of the deuterium retention in long discharges are described in the section 3. (A.C.)

  18. Permanent record. Electronic records aid in the aftermath of Joplin tornado.

    Science.gov (United States)

    Russell, Matthew

    2011-09-01

    When a tornado struck St. John's Regional Medical Center in May 2011, its patient records were stored in a newly launched electronic health record system, helping prevent a bad situation from being worse.

  19. Development of margin assessment methodology of decay heat removal function against external hazards. (2) Tornado PRA methodology

    International Nuclear Information System (INIS)

    Nishino, Hiroyuki; Kurisaka, Kenichi; Yamano, Hidemasa

    2014-01-01

    Probabilistic Risk Assessment (PRA) for external events has been recognized as an important safety assessment method after the TEPCO's Fukushima Daiichi nuclear power station accident. The PRA should be performed not only for earthquake and tsunami which are especially key events in Japan, but also the PRA methodology should be developed for the other external hazards (e.g. tornado). In this study, the methodology was developed for Sodium-cooled Fast Reactors paying attention to that the ambient air is their final heat sink for removing decay heat under accident conditions. First, tornado hazard curve was estimated by using data recorded in Japan. Second, important structures and components for decay heat removal were identified and an event tree resulting in core damage was developed in terms of wind load and missiles (i.e. steel pipes, boards and cars) caused by a tornado. Main damage cause for important structures and components is the missiles and the tornado missiles that can reach those components and structures placed on high elevations were identified, and the failure probabilities of the components and structures against the tornado missiles were calculated as a product of two probabilities: i.e., a probability for the missiles to enter the intake or outtake in the decay heat removal system, and a probability of failure caused by the missile impacts. Finally, the event tree was quantified. As a result, the core damage frequency was enough lower than 10 -10 /ry. (author)

  20. Study on the materials for mirrors and back mirror reflectors of thermonuclear reactors and their testing in Tore-Supra

    International Nuclear Information System (INIS)

    Schunke, B.; Voytsenya, V.; Gil, C.; Lipa, M.

    2003-01-01

    Plasma diagnostics using visible or ultra-violet or infra-red radiations require mirrors to probe the plasma. These mirrors have to sustain very hostile environment and despite that must maintain good optical properties. Mirror samples made of 3 different metals: copper, stainless steel and molybdenum have been designed and installed in Tore Supra tokamak and will be exposed to plasmas till mid 2004. This project will allow fusion engineers to assess the impact of plasma ion bombardment on mirror reflectivity. Optical properties and parameters concerning the surface state of the samples have been measured before the installation in Tore Supra and are presented in the paper. Simulations with a Monte-Carlo code predict the particle flux and spectra near the samples. A specific back mirror reflector has been designed to probe mirror reflectivity changes. (A.C.)

  1. Development of a design basis tornado and structural design criteria for the Nevada Test Site, Nevada. Final report

    International Nuclear Information System (INIS)

    McDonald, J.R.; Minor, J.E.; Mehta, K.C.

    1975-06-01

    In order to evaluate the ability of critical facilities at the Nevada Test Site to withstand the possible damaging effects of extreme winds and tornadoes, parameters for the effects of tornadoes and extreme winds and structural design criteria for the design and evaluation of structures were developed. The meteorological investigations conducted are summarized, and techniques used for developing the combined tornado and extreme wind risk model are discussed. The guidelines for structural design include methods for calculating pressure distributions on walls and roofs of structures and methods for accommodating impact loads from wind-driven missiles. Calculations for determining the design loads for an example structure are included

  2. Hawkmoth flight performance in tornado-like whirlwind vortices.

    Science.gov (United States)

    Ortega-Jimenez, Victor Manuel; Mittal, Rajat; Hedrick, Tyson L

    2014-06-01

    Vertical vortex systems such as tornadoes dramatically affect the flight control and stability of aircraft. However, the control implications of smaller scale vertically oriented vortex systems for small fliers such as animals or micro-air vehicles are unknown. Here we examined the flapping kinematics and body dynamics of hawkmoths performing hovering flights (controls) and maintaining position in three different whirlwind intensities with transverse horizontal velocities of 0.7, 0.9 and 1.2 m s(-1), respectively, generated in a vortex chamber. The average and standard deviation of yaw and pitch were respectively increased and reduced in comparison with hovering flights. Average roll orientation was unchanged in whirlwind flights but was more variable from wingbeat to wingbeat than in hovering. Flapping frequency remained unchanged. Wingbeat amplitude was lower and the average stroke plane angle was higher. Asymmetry was found in the angle of attack between right and left wings during both downstroke and upstroke at medium and high vortex intensities. Thus, hawkmoth flight control in tornado-like vortices is achieved by a suite of asymmetric and symmetric changes to wingbeat amplitude, stroke plane angle and principally angle of attack.

  3. Hawkmoth flight performance in tornado-like whirlwind vortices

    International Nuclear Information System (INIS)

    Ortega-Jimenez, Victor Manuel; Hedrick, Tyson L; Mittal, Rajat

    2014-01-01

    Vertical vortex systems such as tornadoes dramatically affect the flight control and stability of aircraft. However, the control implications of smaller scale vertically oriented vortex systems for small fliers such as animals or micro-air vehicles are unknown. Here we examined the flapping kinematics and body dynamics of hawkmoths performing hovering flights (controls) and maintaining position in three different whirlwind intensities with transverse horizontal velocities of 0.7, 0.9 and 1.2 m s −1 , respectively, generated in a vortex chamber. The average and standard deviation of yaw and pitch were respectively increased and reduced in comparison with hovering flights. Average roll orientation was unchanged in whirlwind flights but was more variable from wingbeat to wingbeat than in hovering. Flapping frequency remained unchanged. Wingbeat amplitude was lower and the average stroke plane angle was higher. Asymmetry was found in the angle of attack between right and left wings during both downstroke and upstroke at medium and high vortex intensities. Thus, hawkmoth flight control in tornado-like vortices is achieved by a suite of asymmetric and symmetric changes to wingbeat amplitude, stroke plane angle and principally angle of attack. (papers)

  4. Real time determination and control of the plasma localisation and internal inductance in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Laurent, F. E-mail: stlauren@drfc.cad.cea.fr; Martin, G

    2001-10-01

    The study of long-duration high-power discharges need an efficient real time control of the plasma parameters, especially the plasma position when RF heating systems are used. On Tore Supra, recent improvements have been carried out (i) for the poloidal interpolation and the radial extrapolation of the magnetic measurements, (ii) for a better feedback matrix converting the radial errors of the plasma position to voltage values for the poloidal generators, and (iii) for a very fast solution to find the plasma parameters from the knowledge of its surface. The plasma edge localisation is now controlled with a precision better than 1 cm and controlled within a few millimetres uncertainty for several tenths of seconds. Moreover, for advanced tokamak scenarios, a precise real time determination of safety factor, poloidal beta, internal inductance, Shafranov shift as well as the online computation of the electron density and current density profiles are now available on Tore Supra. These quantities compare well with results from batch calculations using an equilibrium code. To fulfil the new requirements of plasma control for the CIEL project, a local control of the plasma edge position and curvature is planned for the near future.

  5. Predictive simulations of radio frequency heated plasmas of Tore Supra using the Multi-Mode model

    International Nuclear Information System (INIS)

    Voitsekhovitch, Irina; Bateman, Glenn; Kritz, Arnold H.; Pankin, Alexei

    2002-01-01

    Multichannel integrated predictive simulations using the Multi-Mode transport model are carried out for radio frequency heated Tore Supra tokamak discharges in which helium is the primary ion component. Lower hybrid heated discharges in which the total current is driven noninductively [X. Litaudon et al., Plasma Phys. Controlled Fusion 43, 677 (2001)] and a discharge with ion cyclotron radio frequency heating of the hydrogen minority ions [G. T. Hoang et al., Nucl. Fusion 38, 117 (1998)] are simulated. The simulations of these discharges represent the first test of the Multi-Mode model in helium plasmas with dominant electron heating. Also for the first time, the particle transport in Tore Supra discharges is computed and the density profiles are predicted self-consistently with other transport channels. It is found in these simulations that the anomalous transport driven by trapped electron mode turbulence is dominant compared to the transport driven by the ion temperature gradient turbulence. The feature of the Multi-Mode model to calculate the impurity transport self-consistently with other transport channels is used in this study to predict the influence of carbon impurity influx on the discharge evolution

  6. Coupling properties and edge plasma interaction characteristics of the new Tore Supra lower hybrid antenna

    International Nuclear Information System (INIS)

    Bibet, Ph.; Fuchs, V.; Mailloux, J.

    1999-01-01

    A significant part of the non-inductive in Tore Supra will be driven by a new launcher, to be installed in September 1999. The antenna phase 2 is made of 6 rows with 48 active waveguides and 9 passive ones in each. Passive waveguides are inserted at every 6. active one. This grill has been designed in the frame of the CIEL project. It will inject 4 MW at 3.7 GHz at a safe power density of 25 MW/m 2 for a pulse length of 1000 s. The radiated spectrum peaks at N // = 2.03 with a possible variation of ± 0.35 and a FWHM of 0.35. In order to prepare for operation with this grill, the coupling properties and the power directivity of the radiated spectra have been studied as a function of: the electron density and electron density gradient ; the feeding phase shift between the 8 antenna modules; the geometry of the antenna. Furthermore, the interaction of plasma edge electrons with the antenna is analysed and a comparison with the previous Tore Supra antenna is made. This is done for a range of plasma parameters and feeding phase. (authors)

  7. Thermal electron transport in regimes with low and negative magnetic shear in Tore Supra

    International Nuclear Information System (INIS)

    Voitsekhovitch, I.; Litaudon, X.; Moreau, D.; Aniel, T.; Becoulet, A.; Erba, M.; Joffrin, E.; Kazarian-Vibert, F.; Peysson, Y.

    1997-01-01

    The magnetic shear effect on thermal electron transport is studied in a large variety of non-inductive plasmas in Tore Supra. An improved confinement in the region of low and negative shear was observed and quantified with an exponential dependence on the magnetic shear (Litaudon, et al., Fusion Energy 1996 (Proc. 16th Int. Conf. Montreal, 1996), Vol. 1, IAEA, Vienna (1997) 669). This is interpreted as a consequence of a decoupling of the global modes (Romanelli and Zonca, Phys. Fluids B 5 (1993) 4081) that are thought to be responsible for anomalous transport. This dependence is proposed in order to complete the Bohm-like L mode local electron thermal diffusivity so as to describe the transition from Bohm-like to gyroBohm transport in the plasma core. The good agreement between the predictive simulations of the different Tore Supra regimes (hot core lower hybrid enhanced performance, reversed shear plasmas and combined lower hybrid current drive and fast wave electron heating) and experimental data provides a basis for extrapolation of this magnetic shear dependence in the local transport coefficients to future machines. As an example, a scenario for non-inductive current profile optimization and control in ITER is presented. (author)

  8. Particle pinch with fully noninductive lower hybrid current drive in Tore Supra.

    Science.gov (United States)

    Hoang, G T; Bourdelle, C; Pégourié, B; Schunke, B; Artaud, J F; Bucalossi, J; Clairet, F; Fenzi-Bonizec, C; Garbet, X; Gil, C; Guirlet, R; Imbeaux, F; Lasalle, J; Loarer, T; Lowry, C; Travère, J M; Tsitrone, E

    2003-04-18

    Recently, plasmas exceeding 4 min have been obtained with lower hybrid current drive (LHCD) in Tore Supra. These LHCD plasmas extend for over 80 times the resistive current diffusion time with zero loop voltage. Under such unique conditions the neoclassical particle pinch driven by the toroidal electric field vanishes. Nevertheless, the density profile remains peaked for more than 4 min. For the first time, the existence of an inward particle pinch in steady-state plasma without toroidal electric field, much larger than the value predicted by the collisional neoclassical theory, is experimentally demonstrated.

  9. Study of heat flux deposition in the Tore Supra Tokamak

    International Nuclear Information System (INIS)

    Carpentier, S.

    2009-02-01

    Accurate measurements of heat loads on internal tokamak components is essential for protection of the device during steady state operation. The optimisation of experimental scenarios also requires an in depth understanding of the physical mechanisms governing the heat flux deposition on the walls. The objective of this study is a detailed characterisation of the heat flux to plasma facing components (PFC) of the Tore Supra tokamak. The power deposited onto Tore Supra PFCs is calculated using an inverse method, which is applied to both the temperature maps measured by infrared thermography and to the enthalpy signals from calorimetry. The derived experimental heat flux maps calculated on the toroidal pumped limiter (TPL) are then compared with theoretical heat flux density distributions from a standard SOL-model. They are two experimental observations that are not consistent with the model: significant heat flux outside the theoretical wetted area, and heat load peaking close to the tangency point between the TPL and the last closed field surface (LCFS). An experimental analysis for several discharges with variable security factors q is made. In the area consistent with the theoretical predictions, this parametric study shows a clear dependence between the heat flux length λ q (estimated in the SOL (scrape-off layer) from the IR measurements) and the magnetic configuration. We observe that the spreading of heat fluxes on the component is compensated by a reduction of the power decay length λ q in the SOL when q decreases. On the other hand, in the area where the derived experimental heat loads are not consistent with the theoretical predictions, we observe that the spreading of heat fluxes outside the theoretical boundary increases when q decreases, and is thus not counterbalanced. (author)

  10. Brazing of the Tore Supra actively cooled Phase III Limiter

    International Nuclear Information System (INIS)

    Nygren, R.E.; Walker, C.A.; Lutz, T.J.; Hosking, F.M.; McGrath, R.T.

    1993-01-01

    The head of the water-cooled Tore Supra Phase 3 Limiter is a bank of 14 round OFHC copper tubes, curved to fit the plasma radius, onto which several hundred pyrolytic graphite (PG) tiles and a lesser number of carbon fiber composite tiles are brazed. The small allowable tolerances for fitting the tiles to the tubes and mating of compound curvatures made the brazing and fabrication extremely challenging. The paper describes the fabrication process with emphasis on the procedure for brazing. In the fixturing for vacuum furnace brazing, the tiles were each independently clamped to the tube with an elaborate set of window frame clamps. Braze quality was evaluated with transient heating tests. Some rebrazing was necessary

  11. Pipe/duct system design for tornado missile impact loads

    Energy Technology Data Exchange (ETDEWEB)

    Li, J.; Wang, S.; Johnson, W., E-mail: whjohnso@bechtel.com

    2014-04-01

    For nuclear power plant life extension projects, it may be convenient and in some instances necessary to locate safety-related steel ducts and pipes outside of the main structures, exposing them to extreme environmental loads such as tornado missile impact. Examples of this application include emergency firewater lines and Control Room vent ducts. A typical exposed commodity run could be comprised of a rectangular or circular cross-section with horizontal and vertical segments supported at variable spans off of roof and wall panels, respectively. Efficient and economical design of such a tornado-impacted duct or pipe system, consisting of the commodity and its supports, must exploit all of the system's capability to absorb the impact energy by deforming plastically to the fullest extent allowable. Energy can be absorbed locally in the vicinity of impact on the commodity, globally through rotation at flexural plastic hinges, and through yielding of the supports. In this paper a simplified NDOF lumped parameter nonlinear analysis methodology is presented and applied to the coupled commodity/support system subjected to tornado impulse loading. The analysis methodology is confirmed using a detailed ANSYS nonlinear finite element model. Optimization of the initial trial design is achieved by progressively decreasing the support resistances, while monitoring the response ductilities throughout the system. Evaluation methodologies are provided for the four types of plastic deformation responses which occur in the system: local response in the immediate vicinity of impact, flexural and membrane response of the sidewall out to one or two times the commodity depth beyond the point of impact, global response of the commodity as a beam spanning between supports, and the shear and flexural response of support. The inelastic responses are evaluated against AISC N690 acceptance criteria (ANSI, 2006), supplemented as appropriate by triaxiality considerations for inelastic

  12. Structural performance of HEPA filters under simulated tornado conditions

    International Nuclear Information System (INIS)

    Horak, H.L.; Gregory, W.S.; Ricketts, C.I.; Smith, P.R.

    1982-02-01

    This report contains the results of structural tests to determine the response of High Efficiency Particulate Air filters to simulated tornado conditions. The data include the structural limits of the filters, their resistance at high flow rates, and the effects of filter design features and tornado parameters. Considering all the filters tested, the mean break pressure or structural limit was found to be 2.35 pse (16.2 kPa). The maximum value was 2.87 psi (19.8 kPa), and the low value found was 1.31 psi (9.0 kPa). The type of failure was usually a medium break of the downstream filter fold. The type of filters that were evaluated were nuclear grade with design flow rates of 1000 cfm (0.472 m 3 /s), standard separators, and folded medium design. The parameters evaluated that are characteristic of the filter included manufacturer, separator type, faceguards, pack tightness, and aerosol loading. Manufacturer and medium properties were found to have a large effect on the structural limits

  13. Individual relocation decisions after tornadoes: a multi-level analysis.

    Science.gov (United States)

    Cong, Zhen; Nejat, Ali; Liang, Daan; Pei, Yaolin; Javid, Roxana J

    2018-04-01

    This study examines how multi-level factors affected individuals' relocation decisions after EF4 and EF5 (Enhanced Fujita Tornado Intensity Scale) tornadoes struck the United States in 2013. A telephone survey was conducted with 536 respondents, including oversampled older adults, one year after these two disaster events. Respondents' addresses were used to associate individual information with block group-level variables recorded by the American Community Survey. Logistic regression revealed that residential damage and homeownership are important predictors of relocation. There was also significant interaction between these two variables, indicating less difference between homeowners and renters at higher damage levels. Homeownership diminished the likelihood of relocation among younger respondents. Random effects logistic regression found that the percentage of homeownership and of higher income households in the community buffered the effect of damage on relocation; the percentage of older adults reduced the likelihood of this group relocating. The findings are assessed from the standpoint of age difference, policy implications, and social capital and vulnerability. © 2018 The Author(s). Disasters © Overseas Development Institute, 2018.

  14. Feasibility study of carbon particles injection by laser ablation to calibrate spectroscopic erosion measurements in Tore Supra

    International Nuclear Information System (INIS)

    Naiim Habib, M.; Mercadier, L.; Marandet, Y.; Delaporte, Ph.; Hernandez, C.; Grisolia, C.; Monier-Garbet, P.

    2011-01-01

    To check if spectroscopic measurements can be used for erosion determination, we propose to inject in the line of sight of the diagnostic, during plasma operation, a known carbon particle source, produced by laser ablation. A first assessment of this technique will be presented in the context of the Tore Supra tokamak.

  15. Determination of electromagnetic modes in oversized corrugated waveguides on the electron cyclotron resonance heating installation at the tokamak Tore Supra; Determination de modes electromagnetiques de guides d'ondes corrugues surdimensionnes sur l'installation de chauffage des electrons de tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, L

    2001-03-09

    Electron cyclotron resonance heating (ECRH) in the Tore Supra tokamak constitutes an important step in the research aimed at obtaining thermonuclear fusion reactions. Electron heating is achieved by transmitting an electromagnetic wave from the oscillators (gyrotrons) to the plasma via the fundamental mode, propagating in oversized corrugated waveguides. Maximizing the proportion of the gyrotron power coupled to the fundamental waveguide mode is essential for the good functioning of the transmission line and for maximizing the effect on the plasma. This thesis gives all necessary tools for finding the proportion of the fundamental mode and all other modes present in passive components and at the output of the gyrotron as installed in the Tore Supra ECRH plant. This characterisation is based on obtaining amplitude and phase diagrams of the electric field on a plane transverse to the propagation axis. The most difficult part of obtaining these diagrams is measuring the phase which, despite the very short wavelength, is measured directly at low power levels. At high power levels the phase is numerically reconstructed from amplitude measurements for gyrotron characterisation. A complete theoretical study of the phase reconstruction code is given including its validation with theoretical diagrams. This study allows the realisation of a modal characterisation unit electromagnetic for measurement of radiated beams and usable in each part of the ECRH installation. At the end, the complete modal characterisation is given at low level for a mode converter and also at high level for the first series gyrotron installed at TORE SUPRA. (author)

  16. Thomson scattering upgrade on Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Leroux, F., E-mail: fabrice.leroux@cea.f [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Manenc, L.; Moreau, M. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2010-07-15

    The Thomson scattering diagnostic supplies the electron temperature and density of Tore Supra plasmas from the spectrum analysis of scattered light of a very short laser pulse. A new spectrometer has been realized to improve the signal to noise ratio. In order to obtain an efficient noise reduction, a real time calculation is necessary. The current analogue integration of the signal is inadequate. A fast digitalization must be used with a sampling rate of 1 GSamples/s, a bandwidth of 150 MHz and a 12 bits dynamic range. In a first step, fast analogue data acquisition boards for 4 channels were added in 2009 to the VME acquisition system in place. A MATACQ (Matrix for acquisition) board was chosen for sampling analogue data up to 2 GSamples/s over 4 channels with a large bandwidth of 300 MHz and a 14 bits dynamic range. This solution offers a low cost acquisition system that is not available in any other commercial board with this dynamic range. The first results will be obtained on calibration period with a light emitted diode before the summer 2009. This article will present the new data acquisition system and the coming first results.

  17. Current density profile inside q=1 on Tore Supra

    International Nuclear Information System (INIS)

    Joffrin, E.; Desgranges, C.; Sabot, R.; Dubois, M.A.

    1995-01-01

    The Tore Supra polarimeter used to measure the poloidal field distribution is described. The current density profiles are computed in two different ways using the interferometric and polarimetric data in conjunction with the magnetic data and the location of the inversion radius determined by the soft X-ray camera. The current density inside the q=1 surface is investigated for normal and monster sawteeth. Its variation are also measured by the polarimeter and compared with that predicted by the current diffusion equation assuming complete reconnection. Finally, the safety factor profile is compared with that obtained with the striation data of the pellet ablation. The results of the evolution of the q profile during sawteeth are in good agreement with those obtained in other devices. (author) 9 refs.; 4 figs

  18. Pneumatic injector of deuterium macroparticles for TORE-SUPRA tokamak

    International Nuclear Information System (INIS)

    Vinyar, I.V.; Umov, A.P.; Lukin, A.Ya.; Skoblikov, S.V.; Reznichenko, P.V.; Krasil'nikov, I.A.

    2006-01-01

    The pneumatic injector for periodic injection of fuel-solid-deuterium pellets into the plasma of the TORE-SUPRA tokamak in a steady-state mode is described. The deuterium pellet injection with an unlimited duration is ensured by a screw extruder in which gaseous deuterium is frozen and squeezed outwards in the form of a rod with a rectangular cross section. A cutter installed on the injector's barrel cuts a cylinder with a diameter of 2 mm and a length of 1.0-3.5 mm out from this rod. The movement of the cutter is controlled by a pulsed electromagnetic drive at a pulse repetition rate of 10 Hz. In the injector's barrel, a compressed gas accelerates a deuterium pellet to a velocity of 100-650 m/s [ru

  19. Scrape-off layer flows in the Tore Supra tokamak

    International Nuclear Information System (INIS)

    Gunn, J.P.; Loarer, T.; Saint-Laurent, F.; Bucalossi, J.; Devynck, P.; Hertout, P.; Moreau, P.; Nanobashvili, I.; Rimini, F.; Duran, I.; Fuchs, V.; Panek, R.; Stockel, J.; Adamek, J.; Dejarnac, R.; Hron, M.; Sarkissian, A.

    2005-01-01

    Near-sonic parallel flows are systematically observed in the scrape-off layer (SOL) of the limiter tokamak Tore Supra, as in many X-point divertor tokamaks. The poloidal variation of the Mach number of the parallel flow has been measured by moving the contact point of a small circular plasma onto limiters at different poloidal angles. The resulting variations of flow are consistent with the existence of a poloidally nonuniform core-to-SOL out-flux concentrated near the outboard midplane. Strong variations of the SOL width up to a factor of 10 suggest that this localized out-flux is due to enhanced radial transport. The plasma that gets ejected into the SOL can expand radially to the wall if magnetic field lines have long connection lengths and pass unobstructed across the outboard midplane. (authors)

  20. Analytic studies on satellite detection of severe, two-cell tornadoes

    Science.gov (United States)

    Carrier, G. F.; Dergarabedian, P.; Fendell, F. E.

    1979-01-01

    From funnel-cloud-length interpretation, the severe tornado is characterized by peak swirl speed relative to the axis of rotation of about 90 m/s. Thermohydrodynamic achievement of the pressure deficit from ambient necessary to sustain such swirls requires that a dry, compressionally heated, non-rotating downdraft of initially tropopause-level air lie within an annulus of rapidly swirling, originally low-level air ascending on a near-moist-adiabatic locus of thermodynamic states. The two-cell structure furnishes an observable parameter possibly accessible to a passively instrumented, geosynchronous meteorological satellite with mesoscale resolution, for early detection of a severe tornado. Accordingly, the low-level turnaround region, in which the surface inflow layer separates to become a free ascending layer and for which inviscid modeling suffices, is examined quantitatively. Preliminary results indicate that swirl overshoot, i.e., swirl speeds in the turnaround region in excess of the maximum achieved in the potential vortex, is modest.

  1. Barrier design for tornado-generated missiles

    International Nuclear Information System (INIS)

    Kar, A.K.

    1977-01-01

    Nuclear power plant facilities and many other structures need protection against missiles generated by tornados and explosions. The missile impacts result in both local and overall effects on barriers or targets. The local effects are characterized by penetration, perforation and backface spalling or scabbing of the target material. The overall effects of missile impact on structural stability are commonly evaluated in terms of the flexural and shear behaviour of the target. Empirical formulas are presented to determine the local effects on concrete and steel barriers. Procedures are given for determining the design loads for overall effects. Design methods are described. (Auth.)

  2. Barrier design for tornado-generated missiles

    International Nuclear Information System (INIS)

    Kar, A.K.

    1977-01-01

    Nuclear powerplant facilities and many other structures need protection against missiles generated by tornadoes and explosions. The missile impacts result in both local and overall effects on barriers or targets. The local effects are characterized by penetration, perforation, and backface spalling or scabbing of the target material. The overall effects of missile impact on structural stability are commonly evaluated in terms of the flexural and shear behavior of the target. Empirical formulas are presented to determine the local effects on concrete and steel barriers. Procedures are given for determining the design loads for overall effects. Design methods are described

  3. Feedback control of the lower hybrid power deposition profile on Tore Supra

    International Nuclear Information System (INIS)

    Barana, O; Mazon, D; Laborde, L; Turco, F

    2007-01-01

    The Tore Supra facility is well suited to study ITER relevant topics such as the real-time control of plasma current and the sustaining of steady-state discharges. This work describes a tool that was recently developed and implemented on Tore Supra to control in real time, by means of the direct knowledge of the suprathermal electron local emission profile, the width of the lower hybrid power deposition profile. This quantity can be considered to some extent equivalent to the width of the plasma current density profile in case of fully non-inductive discharges. This system takes advantage of an accurate hard x-ray diagnostics, of an efficient lower hybrid additional heating and of a reliable real-time communication network. The successful experiments carried out to test the system employed, as actuators, the parallel refractive index n // and the total power P LH . The control of the suprathermal electron local emission profile through n // was also integrated with the feedback control of the total plasma current I P with P LH and of the loop voltage V loop with the central solenoid flux. These results demonstrate that the system is robust, reliable and able to counterbalance destabilizing events. This tool can be effectively used in the future in fully non-inductive discharges to improve the MHD stability and to maintain internal transport barriers or lower hybrid enhanced performance modes. The real-time control of the lower hybrid power deposition profile could also be used in conjunction with the electron-cyclotron radiofrequency heating for synergy studies

  4. Tornado damage at the Grand Gulf, Mississippi nuclear power plant site: aerial and ground surveys

    International Nuclear Information System (INIS)

    Fujita, T.T.; McDonald, J.R.

    1978-05-01

    A tornado struck the Grand Gulf nuclear power generating station, Port Gibson, Mississippi, about 11:30 p.m. on April 17, 1978. Storm damage investigators from the University of Chicago and Texas Tech University were dispatched to survey the damage. The meteorological situation that spawned the Grand Gulf tornado and seven others in the area is discussed. Aerial surveys of the entire damage path and detailed surveys of the plant site are presented. An engineering evaluation of the damage is also presented based primarily on information gained from detailed ground surveys

  5. Pioneering superconducting magnets in large tokamaks: evaluation after 16 years of operating experience in tore supra

    International Nuclear Information System (INIS)

    Duchateau, J.L.; Gravil, B.; Tena, E.; Henry, D.; Journeaux, J.Y.; Libeyre, P.

    2004-01-01

    The toroidal field (TF) system of Tore Supra (TS) is superconducting. After 16 years of operation it is possible to give an overview of the experience gained on a large superconducting system integrated in a large Tokamak. Quantitative data will be given, about the TF system for the cryogenic system and for the magnet system as well, concerning the number of plasmas shots and the availability of the machine. The origin and the number of breakdowns or incidents will be described, with emphasis on cryogenics, to document repairs and changes on the system components. Concerning the behaviour during operation, the Fast Safety Discharges (FSD) in operation are of particular interest for the Tokamak operation, as they interrupt it on a significant time of the order of one hour. This aspect is particularly documented. The approach followed to decrease the number of these FSD will be reported and explained. The Tore Supra Tokamak was the first important meeting between Superconductivity and Plasma Physics on a large scale. Overall, despite the differences in design and size, the accumulated experience over 16 years of operation is a useful tool to prepare the manufacturing and the operation of the ITER magnets. (authors)

  6. Synergy between electron cyclotron and lower hybrid current drive on Tore Supra

    International Nuclear Information System (INIS)

    Giruzzi, G.; Artaud, J.F.; Dumont, R.J.; Imbeaux, F.; Bibet, P.; Berger-By, G.; Bouquey, F.; Clary, J.; Darbos, C.; Ekedahl, A.; Hoang, G.T.; Lennholm, M.; Maget, P.; Magne, R.; Segui, J.L.; Bruschi, A.; Granucci, G.

    2005-01-01

    Improvement (up to a factor ∼ 4) of the electron cyclotron (EC) current drive efficiency in plasmas sustained by lower hybrid (LH) current drive has been demonstrated in stationary conditions on the Tore Supra tokamak. This was made possible by feedback controlled discharges at zero loop voltage, constant plasma current and density. This effect, predicted by kinetic theory, results from a favorable interplay of the velocity space diffusions induced by the two waves: the EC wave pulling low-energy electrons out of the Maxwellian bulk, and the LH wave driving them to high parallel velocities. (author)

  7. Electron cyclotron resonance heating assisted plasma startup in the Tore Supra tokamak

    International Nuclear Information System (INIS)

    Bucalossi, J.; Hertout, P.; Lennholm, M.; Saint-Laurent, F.; Bouquey, F.; Darbos, C.; Traisnel, E.

    2009-04-01

    ECRH assisted plasma startup at fundamental resonance is investigated in Tore Supra in view of ITER operation. ECRH pre-ionisation is found to be very efficient allowing plasma initiation in a wide range of pre-fill pressure compared to ohmic startup. Reliable assisted startup has been achieved at the ITER reference toroidal electric field (0.3 V/m) with 160 kW of ECRH. Resonance location scan indicates that the plasma is initiated at the resonance location and that the plasma current channel position had to be real-time controlled since the very beginning of the discharge to obtain robust plasma startup. (authors)

  8. Quench and safety tests on a toroidal field coil of Tore Supra

    International Nuclear Information System (INIS)

    Ciazynski, D.; Cure, C.; Duchateau, J.L.

    1987-01-01

    As a part of the safety analysis of the magnet, three quenches have been initiated in one of the TF coils in the Saclay test facility. While transporting a given current, the coil is insulated from the refrigerator: the temperatures of the helium and of the coil increase slowly on account of thermal losses. At the current sharing temperature a quench rapidly propagates and the protection system makes the coil discharge in the dump resistor. At three levels of current, electrical, thermal and hydraulic measurements have been performed. All these results are taken into account for the safety design of TORE SUPRA

  9. Automated Tracking of Tornado-Producing Mesoscale Convective Systems in the United States

    Science.gov (United States)

    Kuo, K.; Hong, Y.; Clune, T. L.

    2011-12-01

    The great majority of Earth Science events are studied using "snap-shot" observations in time, mainly due to the scarcity of observations with dense temporal coverage and the lack of robust methods amenable to connecting the "snap shots". To enable the studies of these events in the four-dimensional (4D) spatiotemporal space and to demonstrate the utility of this capability, we have applied the neighbor enclosed area tracking (NEAT) method of Inatsu (2009) to three years of high-resolution (in both time and space) NEXRAD-derived and rain-gauge-corrected QE2 precipitation observations and GOES satellite Rapid Scan Operation imagery to track tornado-producing mesoscale convective systems (MCS's). We combine information from the databases of the Tornado History Project (which provides tornado occurrence and trajectory) and the NWS Watch/Warning Archive (which provides severe weather watch/warning locations) to obtain initial estimate of the time and location of a tornado-producing MCS. The NEAT algorithm is then applied to QE2 and GOES data, both forward and backward in time, to identify the entire system as one integral entity from its inception to its eventual dissipation in the 4D spatiotemporal space. For each system so identified, we extract its morphological/structural parameters, such as perimeter length, area, and orientation, from each of the snap shots in time. We also record physical parameters such as minimum and maximum precipitation rates. In addition, we perform areal integral on the precipitation rate field, which in turn enables time integral for the entire MCS throughout its lifecycle to obtain an estimate of the system's precipitation production. We can extend this proof-of-concept prototype to other precipitation producing severe weather events, such as blizzards. Furthermore, the spatiotemporal data collected may be used to discover other data, such as satellite remote sensing observations and model analyses/simulations, which can then be combined

  10. Eddy current calculations for the Tore Supra toroidal field magnet

    International Nuclear Information System (INIS)

    Blum, J.

    1983-01-01

    An outline is given of the calculation of the eddy currents in the magnetic structures of a Tokamak, which can be assimilated to thin conductors, so that the three-dimensional problem can be reduced mathematically to a two-dimensional one, the variables being two orthogonal coordinates of the considered surface. A finite element method has been used in order to treat the complicated geometry of the set of the 18 toroidal field coil casings and mechanical structures of Tore Supra. This eddy current code has been coupled with an axisymmetric equilibrium code in order to simulate typical phases of a Tokamak discharge (plasma current rise, additional heating, disruption, cleaning discharge) and the losses in the toroidal field magnet have thus been calculated. (author)

  11. Measurements of RF-induced sol modifications in Tore Supra tokamak

    International Nuclear Information System (INIS)

    Kubic, Martin; Gunn, James P.; Colas, Laurent; Heuraux, Stephane; Faudot, Eric

    2012-01-01

    Since spring 2011, one of the three ion cyclotron resonance heating (ICRH) antennas in the Tore Supra (TS) tokamak is equipped with a new type of Faraday screen (FS). Results from Radio Frequency (RF) simulations of the new Faraday screen suggest the innovative structure with cantilevered bars and 'shark tooth' openings significantly changes the current flow pattern on the front of the antenna which in turn reduces the RF potential and RF electrical field in particular parallel to the magnetic field lines which contributes to generating RF sheaths. Effects of the new FS operation on RF-induced scrape-off layer (SOL) modifications are studied for different plasma and antenna configurations - scans of strap power ratio imbalance, phasing, injected power and SOL density. (authors)

  12. Temperature gradient driven electron transport in NSTX and Tore Supra

    International Nuclear Information System (INIS)

    Horton, W.; Wong, H.V.; Morrison, P.J.; Wurm, A.; Kim, J.H.; Perez, J.C.; Pratt, J.; Hoang, G.T.; LeBlanc, B.P.; Ball, R.

    2005-01-01

    Electron thermal fluxes are derived from the power balance for Tore Supra (TS) and NSTX discharges with centrally deposited fast wave electron heating. Measurements of the electron temperature and density profiles, combined with ray tracing computations of the power absorption profiles, allow detailed interpretation of the thermal flux versus temperature gradient. Evidence supporting the occurrence of electron temperature gradient turbulent transport in the two confinement devices is found. With control of the magnetic rotational transform profile and the heating power, internal transport barriers are created in TS and NSTX discharges. These partial transport barriers are argued to be a universal feature of transport equations in the presence of invariant tori that are intrinsic to non-monotonic rotational transforms in dynamical systems

  13. Replacement of the instrumentation and control system of Tore Supra

    International Nuclear Information System (INIS)

    Leveque, P.

    1995-02-01

    The control system of the Tore-Supra is a wide and complex system that cannot be interrupted while running without significant consequences on the operating of the machine. Replacing the current system cannot be achieved in a global way without immobilisation and high costs. Therefore partial changes have been decided on. This work presents the detailed analysis of the arrangements and the operating of the system that will be replaced: the pro's and con's that have appeared through experience are related. The possibilities that the new apparatus offers are also examined. A method of step by step replacements had to be set up in order to assess the means, funds, term of achievement, performance and quality of the overall project. (TEC). 15 refs., 29 figs

  14. Assessing Middle School and College Students' Conceptions About Wind, Fog, and Tornadoes

    Science.gov (United States)

    Polito, E.; Monteverdi, J. P.; Garcia, O.; Tanner, K. D.

    2008-12-01

    Meteorological content is presented in K-12 educational standards and in university general education courses, yet little research has been done to explore how students conceptualize weather phenomena. This investigation probes the understanding of students at three cognitive levels-6th grade earth science students, university non-meteorology majors, and meteorology major students-of three meteorological phenomena-wind, fog, and tornadoes. All students were enrolled in schools in San Francisco, CA. The meteorological content chosen for this project-wind, fog, and tornadoes-was deliberate. Wind is a fundamental process on our planet, and has the potential to cause great damage. Students have direct experience with wind on a daily basis. Fog is a dominant feature of San Francisco climatology, and a familiar phenomenon to students living in our region. Tornadoes are associated with devastating winds and represent a destructive weather phenomenon that students only experience indirectly through movies representations and other media outlets. The phases consisted of (a) a fifteen-question survey, (b) written essay assessments, and (c) videotaped interviews. Phase I, a weather survey, was given to the entire population (65 middle school students, 50 university non-meteorology majors, and 10 university meteorology majors) and consisted of 10-15 challenge statements. Challenge statements assert a common misconception or truism and ask the students to rank their level of agreement on a 4-point Likert scale (strongly agree, agree, disagree, strongly disagree). Phase II presented the students a subset of statements and questions, and they were given 5 minutes to explain why they chose their response. To quantify the resulting qualitative data, the written essay assessments were scored using a developed conceptual rubric by multiple observers, using inter-observer reliability to measure agreement in scoring. The results from this phase helped to structure the interview

  15. Epidemiology of tornado destruction in rural northern Bangladesh: risk factors for death and injury.

    Science.gov (United States)

    Sugimoto, Jonathan D; Labrique, Alain B; Ahmad, Salahuddin; Rashid, Mahbubur; Shamim, Abu Ahmed; Ullah, Barkat; Klemm, Rolf D W; Christian, Parul; West, Keith P

    2011-04-01

    The epidemiology of tornado-related disasters in the developing world is poorly understood. An August 2005 post-tornado cohort study in rural Bangladesh identified elevated levels of death and injury among the elderly (≥ 60 years of age) (adjusted odds ratio (AOR) = 8.9 (95 per cent confidence interval (CI): 3.9-20.2) and AOR = 1.6 (95 per cent CI: 1.4-1.8), respectively), as compared to 15-24 year-olds, and among those outdoors versus indoors during the tornado (AOR = 10.4 (95 per cent CI: 5.5-19.9) and AOR = 6.6 (95 per cent CI: 5.8-7.5), respectively). Females were 1.24 times (95 per cent CI: 1.15-1.33) more likely to be injured than males. Elevated risk of injury was significantly associated with structural damage to the house and tin construction materials. Seeking treatment was protective against death among the injured, odds ratio = 0.08 (95 per cent CI: 0.03-0.21). Further research is needed to develop injury prevention strategies and to address disparities in risk between age groups and between men and women. © 2011 The Author(s). Disasters © Overseas Development Institute, 2011.

  16. Wind field and trajectory models for tornado-propelled objects

    International Nuclear Information System (INIS)

    Anon

    1978-01-01

    This report contains the results of the second phase of a research program which has as its objective the development of a mathematical model to predict the trajectory of tornado-borne objects postulated to be in the vicinity of nuclear power plants. An improved tornado wind field model satisfies the no-slip ground boundary condition of fluid mechanics and includes the functional dependence of eddy viscosity with altitude. Sub-scale wind tunnel data are obtained for all of the missiles currently specified for nuclear plant design. Confirmatory full-scale data are obtained for a 12-inch pipe and automobile. The original six-degree-of-freedom trajectory model is modified to include the improved wind field and increased capability as to body shapes and inertial characteristics that can be handled. The improved trajectory model is used to calculate maximum credible speeds, which for all of the heavy missiles are considerably less than those currently specified for design. Equivalent coefficients for use in three-degree-of-freedom models are developed and the sensitivity of range and speed to various trajectory parameters for the 12-inch diameter pipe is examined

  17. Twitter as a Potential Disaster Risk Reduction Tool. Part II: Descriptive Analysis of Identified Twitter Activity during the 2013 Hattiesburg F4 Tornado.

    Science.gov (United States)

    Cooper, Guy Paul; Yeager, Violet; Burkle, Frederick M; Subbarao, Italo

    2015-06-29

    This article describes a novel triangulation methodological approach for identifying twitter activity of regional active twitter users during the 2013 Hattiesburg EF-4 Tornado. A data extraction and geographically centered filtration approach was utilized to generate Twitter data for 48 hrs pre- and post-Tornado. The data was further validated using six sigma approach utilizing GPS data. The regional analysis revealed a total of 81,441 tweets, 10,646 Twitter users, 27,309 retweets and 2637 tweets with GPS coordinates. Twitter tweet activity increased 5 fold during the response to the Hattiesburg Tornado.  Retweeting activity increased 2.2 fold. Tweets with a hashtag increased 1.4 fold. Twitter was an effective disaster risk reduction tool for the Hattiesburg EF-4 Tornado 2013.

  18. Study of the electron heat transport in Tore-Supra tokamak; Etude du transport de la chaleur electronique dans le Tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Harauchamps, E

    2004-07-01

    This work presents analytical solutions to the electron heat transport equation involving a damping term and a convection term in a cylindrical geometry. These solutions, processed by Matlab, allow the determination of the evolution of the radial profile of electron temperature in tokamaks during heating. The modulated injection of waves around the electron cyclotron frequency is an efficient tool to study heat transport experimentally in tokamaks. The comparison of these analytical solutions with experimental results from Tore-Supra during 2 discharges (30550 and 31165) shows the presence of a sudden change for the diffusion and damping coefficients. The hypothesis of the presence of a pinch spread all along the plasma might explain the shape of the experimental temperature profiles. These analytical solutions could be used to determine the time evolution of plasma density as well or of any parameter whose evolution is governed by a diffusion-convection equation. (A.C.)

  19. Experimental characterization and modelling of non-linear coupling of the lower hybrid current drive power on Tore Supra

    Science.gov (United States)

    Preynas, M.; Goniche, M.; Hillairet, J.; Litaudon, X.; Ekedahl, A.; Colas, L.

    2013-01-01

    To achieve steady-state operation on future fusion devices, in particular on ITER, the coupling of the lower hybrid wave must be optimized on a wide range of edge conditions. However, under some specific conditions, deleterious effects on the lower hybrid current drive (LHCD) coupling are sometimes observed on Tore Supra. In this way, dedicated LHCD experiments have been performed using the LHCD system of Tore Supra, composed of two different conceptual designs of launcher: the fully active multi-junction (FAM) and the new passive active multi-junction (PAM) antennas. A non-linear interaction between the electron density and the electric field has been characterized in a thin plasma layer in front of the two LHCD antennas. The resulting dependence of the power reflection coefficient (RC) with the LHCD power is not predicted by the standard linear theory of the LH wave coupling. A theoretical model is suggested to describe the non-linear wave-plasma interaction induced by the ponderomotive effect and implemented in a new full wave LHCD code, PICCOLO-2D (ponderomotive effect in a coupling code of lower hybrid wave-2D). The code self-consistently treats the wave propagation in the antenna vicinity and its interaction with the local edge plasma density. The simulation reproduces very well the occurrence of a non-linear behaviour in the coupling observed in the LHCD experiments. The important differences and trends between the FAM and the PAM antennas, especially a larger increase in RC for the FAM, are also reproduced by the PICCOLO-2D simulation. The working hypothesis of the contribution of the ponderomotive effect in the non-linear observations of LHCD coupling is therefore validated through this comprehensive modelling for the first time on the FAM and PAM antennas on Tore Supra.

  20. Experimental characterization and modelling of non-linear coupling of the lower hybrid current drive power on Tore Supra

    International Nuclear Information System (INIS)

    Preynas, M.; Goniche, M.; Hillairet, J.; Litaudon, X.; Ekedahl, A.; Colas, L.

    2013-01-01

    To achieve steady-state operation on future fusion devices, in particular on ITER, the coupling of the lower hybrid wave must be optimized on a wide range of edge conditions. However, under some specific conditions, deleterious effects on the lower hybrid current drive (LHCD) coupling are sometimes observed on Tore Supra. In this way, dedicated LHCD experiments have been performed using the LHCD system of Tore Supra, composed of two different conceptual designs of launcher: the fully active multi-junction (FAM) and the new passive active multi-junction (PAM) antennas. A non-linear interaction between the electron density and the electric field has been characterized in a thin plasma layer in front of the two LHCD antennas. The resulting dependence of the power reflection coefficient (RC) with the LHCD power is not predicted by the standard linear theory of the LH wave coupling. A theoretical model is suggested to describe the non-linear wave–plasma interaction induced by the ponderomotive effect and implemented in a new full wave LHCD code, PICCOLO-2D (ponderomotive effect in a coupling code of lower hybrid wave-2D). The code self-consistently treats the wave propagation in the antenna vicinity and its interaction with the local edge plasma density. The simulation reproduces very well the occurrence of a non-linear behaviour in the coupling observed in the LHCD experiments. The important differences and trends between the FAM and the PAM antennas, especially a larger increase in RC for the FAM, are also reproduced by the PICCOLO-2D simulation. The working hypothesis of the contribution of the ponderomotive effect in the non-linear observations of LHCD coupling is therefore validated through this comprehensive modelling for the first time on the FAM and PAM antennas on Tore Supra. (paper)

  1. Mental Health Among Adolescents Exposed to a Tornado: The Influence of Social Support and its Interactions with Socio-Demographic Characteristics and Disaster Exposure

    Science.gov (United States)

    Paul, Lisa A.; Felton, Julia W.; Adams, Zachary W.; Welsh, Kyleen; Miller, Stephanie; Ruggiero, Kenneth J.

    2015-01-01

    Approximately 25% of youths experience a natural disaster and many experience disaster-related distress, including symptoms of posttraumatic stress disorder (PTSD) and depression. This study contributes to the literature by examining PTSD and depressive symptoms among 2,000 adolescents (50.9% female, 70.5% White) assessed after exposure to tornadoes in 2011. The authors hypothesized that greater tornado exposure, female sex, and younger age would be associated with distress, and that social support would interact with these associations. Analyses showed that PTSD symptoms were predicted by lower levels of social support (β = −.28, p tornado exposure (β = .14, ptornado exposure, sex, and social support (β = −.06, p = .017). For boys, the influence of tornado exposure on PTSD symptoms increased as social support decreased. Regardless of level of tornado exposure, low social support was related to PTSD symptoms for girls; depressive symptom results were similar. These findings are generally consistent with the literature and provide guidance for intervention development focused on strengthening social support at the individual, family, and community levels. PMID:26031997

  2. The tornado history of the Czech Lands, AD 1119–2010

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Chromá, Kateřina; Dobrovolný, Petr; Černoch, Z.

    2012-01-01

    Roč. 118, NOV 2012 (2012), s. 193-204 ISSN 0169-8095 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0073 Keywords : Tornado * Spatio-temporal fluctuations * Impacts * Documentary data * Czech Lands Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 2.200, year: 2012

  3. Study of the effects of a tornado on a nuclear plant(from the point of view of civil engineering)

    International Nuclear Information System (INIS)

    Melendro, J.

    2010-01-01

    is to analyze the applicability of Regulatory Guide 1.76 d esign basis Tornado and Tornado Missiles for Nuclear Power Plants , assessing the guide / standard compliance of a nuclear facility with respect to it, identifying the actions required for the compliance if applicable and valuation, with engineering judgment, the benefits for the plant would total or partial implantation of the guide.

  4. Deuterium inventory in Tore Supra: reconciling particle balance and post-mortem analysis

    International Nuclear Information System (INIS)

    Tsitrone, E.; Brosset, C.; Pegourie, B.; Gauthier, E.; Bouvet, J.; Bucalossi, J.; Carpentier, S.; Corre, Y.; Delchambre, E.; Dittmar, T.; Douai, D.; Ekedahl, A.; Ghendrih, Ph.; Grisolia, C.; Grosman, A.; Gunn, J.; Hong, S.H.; Desgranges, L.; Escarguel, A.; Jacob, W.

    2009-01-01

    Fuel retention, a crucial issue for next step devices, is assessed in present-day tokamaks using two methods: particle balance performed during shots and post-mortem analysis carried out during shutdowns between experimental campaigns. Post-mortem analysis generally gives lower estimates of fuel retention than integrated particle balance. In order to understand the discrepancy between these two methods, a dedicated experimental campaign has been performed in Tore Supra to load the vessel walls with deuterium (D) and monitor the trapped D inventory through particle balance. The campaign was followed by an extensive post-mortem analysis phase of the Tore Supra limiter. This paper presents the status of the analysis phase, including the assessment of the D content in the castellated tile structure of the limiter. Indeed, using combined surface analysis techniques, it was possible to derive the relative contributions of different zones of interest on the limiter (erosion, thick deposits, thin deposits), showing that the post-mortem inventory is mainly due to codeposition (90% of the total), in particular due to gap deposits. However, deuterium was also evidenced deep into the material in erosion zones (10% of the total). At the present stage of the analysis, 50% of the inventory deduced from particle balance has been found through post-mortem analysis, a significant progress with respect to previous studies (factor 8-10 discrepancy). This shows that post-mortem analysis can be consistent with particle balance provided specific procedures are implemented (dedicated campaign followed by extensive post-mortem analysis). Both techniques are needed for a reliable assessment of fuel retention in tokamaks, giving complementary information on how much and where fuel is retained in the vessel walls.

  5. An observational study of the 7 September 2005 Barcelona tornado outbreak

    Directory of Open Access Journals (Sweden)

    J. Bech

    2007-01-01

    Full Text Available This paper presents an observational study of the tornado outbreak that took place on the 7 September 2005 in the Llobregat delta river, affecting a densely populated and urbanised area and the Barcelona International airport (NE Spain. The site survey confirmed at least five short-lived tornadoes. Four of them were weak (F0, F1 and the other one was significant (F2 on the Fujita scale. They started mostly as waterspouts and moved later inland causing extensive damage estimated in 9 million Euros, three injured people but fortunately no fatalities. Large scale forcing was provided by upper level diffluence and low level warm air advection. Satellite and weather radar images revealed the development of the cells that spawned the waterspouts along a mesoscale convergence line in a highly sheared and relatively low buoyant environment. Further analysis indicated characteristics that could be attributed indistinctively to non-supercell or to mini-supercell thunderstorms.

  6. Response of centrifugal blowers to simulated tornado transients, July-September 1981

    International Nuclear Information System (INIS)

    Idar, E.S.; Gregory, W.S.; Martin, R.A.; Littleton, P.E.

    1982-03-01

    During this quarter, quasi-steady and dynamic testing of the 24-in. centrifugal blower was completed using the blowdown facility located at New Mexico State University. The data were obtained using a new digital data-acquisition system. Software was developed at the Los Alamos National Laboratory to reduce the dynamic test data and create computer-generated movies showing the dynamic performance of the blower under simulated tornado transient pressure conditions relative to its quasi-steady-state performance. Currently, quadrant-four (outrunning flow) data have been reduced for the most severe and a less severe tornado pressure transient. The results indicate that both the quasi-steady and dynamic blower performance are very similar. Some hysteresis in the dynamic performance occurs because of rotational inertia effects in the blower rotor and drive system. Currently quadrant-two (backflow) data are being transferred to the LTSS computer system at Los Alamos and will be reduced shortly

  7. Simulation of the Tornado Event of 22 March, 2013 over ...

    Indian Academy of Sciences (India)

    An attempt has been made to simulate this rare event using the Weather Research and Forecasting (WRF) model. The model was run in a single domain at 9 km resolution for a period of 24 hrs, starting at 0000 UTC on 22 March, 2013. The meteorological conditions that led to form this tornado have been analyzed.

  8. Edge plasma density convection during ICRH on Tore Supra

    International Nuclear Information System (INIS)

    Becoulet, M.; Colas, L.; Gunn, J.; Ghendrih, Ph.; Becoulet, A.; Pecoul, S.; Heuraux, S.

    2001-11-01

    The 2D edge plasma density distribution around ion cyclotron resonance heating (ICRH) antennae is studied experimentally and numerically in the tokamak Tore Supra (TS). A local density decrease in front of the loaded ICRH antenna ('pump-out' effect) is demonstrated by Langmuir probe measurements in a low recycling regime. An up-down asymmetry in the heat-flux and in the antenna erosion is also observed, and is associated with poloidal variations of the local density. These density redistributions are ascribed to an ExB convection process linked with RF-sheaths. To assess this interpretation, the 2D transport code CELLS was developed for modeling the density distribution near an antenna. The code takes into account perpendicular diffusion, parallel transport and convection in RF-sheath-driven potentials given by the 3D-antenna code ICANT. The strong density differences obtained in simulations reproduce up-down asymmetries of the heat fluxes. (authors)

  9. Interaction of ICRF power and edge plasma in Tore Supra ergodic divertor configuration

    International Nuclear Information System (INIS)

    Nguyen, F.; Grosman, A.; Basiuk, V.; Fraboulet, D.; Beaumont, B.; Becoulet, A.; Ghendrih, Ph.; Ladurelle, L.; Meslin, B.

    2000-01-01

    The coupling of ICRF power to plasma is a crucial problem in Tore Supra for high power and long pulse operations and depends greatly on the edge parameters, in particular on the edge density. Conversely, the behaviour of the bulk plasma is related to the edge conditions and the injection of RF power also induces major modifications on the edge plasma. Moreover, the Ergodic Divertor (ED) of Tore Supra imposes a complex configuration at the edge due to the presence of the magnetic perturbation. Several diagnostics are available to study the interaction of ICRF power with the edge plasma: Langmuir probes on the ED modules, infra red (IR) cameras, charge exchange neutral analysers. In minority heating scheme, the edge density is very sensitive to any perturbation in the high recycling regime which is always found in the ED configuration for relevant plasma parameters. Partially detached regimes, with or without inhomogeneities of density and temperature induced by the flux tubes of the laminar layer, are obtained for high resistance coupling values. The coupling is then not very robust and feedback control or antenna automatic matching techniques are developed. In fast wave electron heating scheme with ED, various fast wave absorption mechanisms (minority heating, Mode Conversion, Alfven resonance) are present at the plasma edge due to the large size of the plasma. The ICRF coupling is difficult due to the low fast wave direct electron damping, even with high hydrogen minority scheme. An increase of the injected ICRF power could improve this situation

  10. Study of plasma turbulence by ultrafast sweeping reflectometry on the Tore Supra Tokamak

    International Nuclear Information System (INIS)

    Hornung, Gregoire

    2013-01-01

    The performance of a fusion reactor is closely related to the turbulence present in the plasma. The latter is responsible for anomalous transport of heat and particles that degrades the confinement. The measure and characterization of turbulence in tokamak plasma is therefore essential to the understanding and control of this phenomenon. Among the available diagnostics, the sweeping reflectometer installed on Tore Supra allows to access the plasma density fluctuations from the edge to the centre of the plasma discharge with a fine spatial (mm) and temporal resolution (μs), that is of the order of the characteristic turbulence scales.This thesis consisted in the characterization of plasma turbulence in Tore Supra by ultrafast sweeping reflectometry measurements. Correlation analyses are used to quantify the spatial and temporal scales of turbulence as well as their radial velocity. In the first part, the characterization of turbulence properties from the reconstructed plasma density profiles is discussed, in particular through a comparative study with Langmuir probe data. Then, a parametric study is presented, highlighting the effect of collisionality on turbulence, an interpretation of which is proposed in terms of the stabilization of trapped electron turbulence in the confined plasma. Finally, it is shown how additional heating at ion cyclotron frequency produces a significant though local modification of the turbulence in the plasma near the walls, resulting in a strong increase of the structure velocity and a decrease of the correlation time. The supposed effect of rectified potentials generated by the antenna is investigated via numerical simulations. (author) [fr

  11. Real time control of fully non-inductive operation in Tore Supra leading to 6 minutes, 1 giga-joule plasma discharges

    International Nuclear Information System (INIS)

    Van Houtte, D.; Martin, G.; Becoulet, A.; Saoutic, B.

    2004-01-01

    The experimental programme of Tore Supra (a = 0.72 m, R = 2.4 m, I p T < 4.5 T) has been devoted in 2003 to study simultaneously heat removal capability and particle exhaust in steady-state fully non-inductive current drive discharges. This required both advanced technology integration and steady-state real time plasma control. In particular, an improvement of the plasma position within a few millimetre range, and new real time cross controls between radio frequency (RF) power and various actuators built around a shared memory network, have allowed Tore Supra to access a powerful steady-state regime with an improved safety level for the actively cooled plasma facing components. Feedback controlled fully non-inductive plasma discharges have been sustained in a steady-state regime up to 6 minutes with a new world record of injected-extracted energy exceeding 1 GJ. Advanced tools, experimental results and brief physics analysis of these discharges are presented and discussed. (authors)

  12. Real time control of fully non-inductive operation in Tore Supra leading to 6 minutes, 1 giga-joule plasma discharges

    Energy Technology Data Exchange (ETDEWEB)

    Van Houtte, D.; Martin, G.; Becoulet, A.; Saoutic, B

    2004-07-01

    The experimental programme of Tore Supra (a = 0.72 m, R = 2.4 m, I{sub p} < 1.7 MA, B{sub T} < 4.5 T) has been devoted in 2003 to study simultaneously heat removal capability and particle exhaust in steady-state fully non-inductive current drive discharges. This required both advanced technology integration and steady-state real time plasma control. In particular, an improvement of the plasma position within a few millimetre range, and new real time cross controls between radio frequency (RF) power and various actuators built around a shared memory network, have allowed Tore Supra to access a powerful steady-state regime with an improved safety level for the actively cooled plasma facing components. Feedback controlled fully non-inductive plasma discharges have been sustained in a steady-state regime up to 6 minutes with a new world record of injected-extracted energy exceeding 1 GJ. Advanced tools, experimental results and brief physics analysis of these discharges are presented and discussed. (authors)

  13. The control of plasma density profile in Tore Supra. Comparison of different fueling techniques

    International Nuclear Information System (INIS)

    Commaux, N.

    2007-09-01

    The behaviour of a reactor-class plasma when fuelled using the existing techniques (gas puffing, supersonic molecular beam injection and pellet injection) is still very difficult to foresee. The present work has been initiated on Tore Supra in order to extrapolate the consequences of the different fuelling systems on ITER. Two main topics have been studied: the comparison of the plasma behaviour when fuelled using the different techniques at high Greenwald density fractions and the study of the homogenization following a pellet injection (main fuelling technique for ITER burning plasmas). The experiments at high Greenwald density fractions performed on Tore Supra showed that the plasma behaviour is very dependent on the fuelling method. The plasma energy confinement is following the scaling laws determined at low density when fuelled using pellet injection. which is better than for gas puffing and SMBI. both inducing a significant confinement loss. This behaviour is nor related to a transport modification: the ratio between effective diffusion and convection is similar to the pellet case. The difference between these shots is related only to the position of the matter source (at the edge for gas and close to the center for pellets). The study concerning the homogenization phenomena following a pellet injection aims mainly to study the ∇B-drift effect that expels the mater deposited by a pellet toward the low field side. A new phenomenon. which appears to be particularly important for the ∇B-drift during low field side injections. was then discovered: the influence of magnetic surfaces with an integer-valued safety factor (q). When the mater drifting toward low field side crosses an integer q surface. it experiences an important braking effect which stops the drift motion. It implies that the pellet material is mainly deposited on the last integer q surface crossed by the pellet during its injection. This study allows also to determine that the

  14. Pioneering superconducting magnets in large tokamaks: Evaluation after 16 years of operating experience in tore supra

    International Nuclear Information System (INIS)

    Libeyre, P.; Duchateau, J.L.; Gravil, B.; Tena, E.; Henry, D.; Journeaux, J.Y.

    2005-01-01

    The toroidal field (TF) system of TORE SUPRA (TS) is superconducting. After 16 years of operation it is possible to give an overview of the experience gained on a large superconducting system integrated in a large Tokamak. Quantitative data will be given, about the TF system for the cryogenic system and for the magnet system as well, concerning the number of plasmas shots and the availability of the machine. The origin and the number of breakdowns or incidents will be described, with emphasis on cryogenics and associated repairs and changes on the system components along the time. As concerns the behaviour during operation, the fast safety discharges (FSD) in operation are of particular interest for the Tokamak operation, as they interrupt it for a significant time of the order of 1 h. This aspect is particularly documented. The approach followed to decrease the number of these FSD will be reported and explained. The TORE SUPRA Tokamak was the first important application of superconductivity in plasma physics on a large scale. Overall, despite the differences in design and size, the accumulated experience over 16 years of operation is a useful tool to prepare the manufacture and the operation of the ITER magnets

  15. An H minority heating regime in Tore Supra showing improved L mode confinement

    International Nuclear Information System (INIS)

    Hoang, G.T.; Monier-Garbet, P.; Aniel, T.

    2000-01-01

    Tore Supra experiments are at present devoted to the study of high density regimes with radiofrequency heating. Recently, an improved L mode confinement regime has been observed in plasmas heated by ion cyclotron hydrogen minority heating, at relatively high densities up to 80% of the Greenwald limit. The quality of energy confinement is as good as that of ELMy H mode. The main physical mechanism of this regime has not been clearly identified. However, some features very similar to those of previous improved confinement modes using neutral beam heating in other tokamaks have been observed. (author)

  16. Experiments on FW-IBW mode conversion heating combined with LHCD on Tore Supra

    International Nuclear Information System (INIS)

    Basiuk, V.; Becoulet, A.; Imbeaux, F.; Nguyen, F.; Peysson, Y.; Monakhov, I.; Petrov, Y.; Petrov, Y.

    1999-01-01

    Recent RF heating and current drive investigations revealed a growing interest in a scheme based on mode conversion (MC) of externally excited fast waves (FW) to ion Bernstein waves (IBW). Suitability of MC scheme for on/off axis electron heating has already been reported on Tore Supra. New results, which were obtained during MC experiments combined with Low Hybrid Current Drive (LHCD) are presented in this paper. Application of new experimental tools and numerical techniques provided better insight into the problem of MC power deposition. an outcome of active search for synergistic LHCD-IBW current drive effects is also reported

  17. Gliding arc in tornado using a reverse vortex flow

    International Nuclear Information System (INIS)

    Kalra, Chiranjeev S.; Cho, Young I.; Gutsol, Alexander; Fridman, Alexander; Rufael, Tecle S.

    2005-01-01

    The present article reports a new gliding arc (GA) system using a reverse vortex flow ('tornado') in a cylindrical reactor (gliding arc in tornado, or GAT), as used to preserve the main advantages of traditional GA systems and overcome their main drawbacks. The primary advantages of traditional GA systems retained in the present GAT are the possibility to generate transitional plasma and to avoid considerable electrode erosion. In contrast to a traditional GA, the new GAT system ensures much more uniform gas treatment and has a significantly larger gas residence time in the reactor. The present article also describes the design of the new reactor and its stable operation regime when the variation of GAT current is very small. These features are understood to be very important for most viable applications. Additionally the GAT provides near-perfect thermal insulation from the reactor wall, indicating that the present GAT does not require the reactor wall to be constructed of high-temperature materials. The new GAT system, with its unique properties such as a high level of nonequilibrium and a large residence time, looks very promising for many industrial applications including fuel conversion, carbon dioxide conversion to carbon monoxide and oxygen, surface treatment, waste treatment, flame stabilization, hydrogen sulfide treatment, etc

  18. Geomorphological impacts of a tornado disturbance in a subtropical forest

    Science.gov (United States)

    Jonathan Phillips; Daniel A. Marion; Chad Yocum; Stephanie H. Mehlhope; Jeff W. Olson

    2015-01-01

    We studied tree uprooting associated with an EF2 tornado that touched down in portions of the Ouachita Mountains in western Arkansas in 2009. In the severe blowdown areas all trees in the mixed shortleaf pine–hardwood forest were uprooted or broken, with no relationship between tree species or size and whether uprooting or breakage occurred. There was also no...

  19. Routine average effective charge calculation using visible Bremsstrahlung emission and comparison with the impurity transport code of Tore Supra

    International Nuclear Information System (INIS)

    Guirlet, R.; Mattioli, M.; DeMichelis, C.; Hess, W.; Pecquet, A.L.

    1995-01-01

    Effective charge measurements and calculations are presented for the Tore Supra, using visible Bremsstrahlung diagnostics. The measurements, are presented together with a reliability test of the results are discussed, by means of an impurity transport code simulating all available experimental data (XUV line spectroscopy, soft X-ray emission and Bremsstrahlung). (author) 5 refs.; 10 figs

  20. Multichannel and multicolor infrared thermography in Tore Supra

    International Nuclear Information System (INIS)

    Reichle, R.; Pocheau, C.; Balorin, C.; Delchambre, E.; Desgrange, C.; Guilhem, D.; Messina, P.; Roche, H.

    2004-01-01

    An imaging spectrometer using a sapphire prism as dispersing element has been conceived at Tore Supra for the spectral range of 1 - 4 μm. It measures simultaneously at various wavelengths the temperature on distributed high heat-flux elements under plasma impact with 36 optical fibres, 4 of which are ZrF 4 fibres. It employs an InSb focal plane array detector (256*320 pixels) behind a silicon filter and a ZnS window yielding a dynamic range of 200 to 1500 deg C with 20 ms temporal resolution. The fibre transmission and the spatial variation of gain and background of the camera are calibrated using a light source with integrating sphere. With a black body source one determines the non linearity of the average gain and controls its stability during operation. The spectral dispersion of about 30 nm/pixel is determined with interference filters and controlled with a spectral lamp. The measurements at various wavelengths allow to determine the temperature distribution in the held of view. (author)

  1. Leak tightness tests on actively cooled plasma facing components: Lessons learned from Tore Supra experience and perspectives for the new fusion machines

    Energy Technology Data Exchange (ETDEWEB)

    Chantant, M., E-mail: michel.chantant@cea.fr; Lambert, R.; Gargiulo, L.; Hatchressian, J.-C.; Guilhem, D.; Samaille, F.; Soler, B.

    2015-10-15

    Highlights: • Test procedures for the qualification of the tightness of actively cooled plasma facing components were defined. • The test is performed after the component manufacturing and before its set-up in the vacuum vessel. • It allows improving the fusion machine availability. • The lessons of tests over 20 years at Tore Supra are presented. - Abstract: The fusion machines under development or construction (ITER, W7X) use several hundreds of actively cooled plasma facing components (ACPFC). They are submitted to leak tightness requirements in order to get an appropriate vacuum level in the vessel to create the plasma. During the ACPFC manufacturing and before their installation in the machine, their leak tightness performance must be measured to check that they fulfill the vacuum requirements. A relevant procedure is needed which allows to segregate potential defects. It must also be optimized in terms of test duration and costs. Tore Supra, as an actively cooled Tokamak, experienced several leaks on ACPFCs during the commissioning and during the operation of the machine. A test procedure was then defined and several test facilities were set-up. Since 1990 the tightness of all the new ACPFCs is systematically tested before their installation in Tore Supra. During the qualification test, the component is set up in a vacuum test tank, and its cooling circuits are pressurized with helium. It is submitted to 3 temperature cycles from room temperature up to the baking temperature level in Tore Supra (200 °C) and two pressurization tests are performed (6 MPa at room temperature and 4 MPa at 200 °C) at each stage. At the end of the last cycle when the ACPFC is at room temperature and pressurized with helium at 6 MPa, the measured leak rate must be lower than 5 × 10{sup −11} Pa m{sup 3} s{sup −1}, the pressure in the test tank being <5 × 10{sup −5} Pa. A large experience has been gained on ACPFCs with carbon parts on stainless steel and Cu

  2. Sounding-derived parameters associated with large hail and tornadoes in the Netherlands

    NARCIS (Netherlands)

    Groenemeijer, P.H.; van Delden, A.J.|info:eu-repo/dai/nl/072670703

    2007-01-01

    A study is presented focusing on the potential value of parameters derived from radiosonde data or data from numerical atmospheric models for the forecasting of severe weather associated with convective storms. Parameters have been derived from soundings in the proximity of large hail, tornadoes

  3. New fast switches for the Tore Supra ohmic heating circuit

    International Nuclear Information System (INIS)

    Zunino, K.; Bruneth, J.; Cara, P.; Louart, A.; Santagiustina, A.; Emelyanova, I.; Filippov, F.; Mikailov, N.

    2003-01-01

    The Tore-Supra ohmic heating circuit is equipped with four fast make switches and one fast opening switch. After many years of operation, it became necessary to substitute this equipment by modern components with similar ratings. An extensive research has been undertaken to find fast switches able to withstand more than 2500 operations per year without maintenance, at a make current of 54 kA, a voltage of 12 kV and with a closing time of less than 15 ms. At the end of the investigation, it was decided to replace the old components by fast mechanical switches proposed by the Efremov Institute and based on a prototype developed for ITER. This paper presents the technical requirements and the characteristics of the switches and describes the operational experience gained with these components during operating campaigns of 2002 and 2003. (authors)

  4. Overview of recent results from the Tore Supra ECE diagnostics

    International Nuclear Information System (INIS)

    Talvard, M.; Liu, W.D.; Giruzzi, G.

    1993-01-01

    The Tore Supra ECE diagnostic system consists of a set of 3 Michelson and 12 Fabry-Perot interferometers, which is now fully operational. We present results obtained with the 3 Michelson during LHCD experiments first. It is shown how the sensitivity of the diagnostic to rather high v (perpendicular) prevents detection of v (parallel) anisotropies. On the other hand, measurements during the Ohmic phase reveal some unexpected anisotropy which can be attributed to superthermal electrons related to the bootstrap current. The 12 Fabry-Perot have been operated using high acquisition sampling rates during pellet injection experiments. A shudder preceding the pellet itself is clearly evidenced just before an internal disruption occurs. During sawtooth activity, such measurements are also used to study the dynamics of the m=1, n=1 instability on the q=1 surface itself

  5. Edge plasma density convection during ICRH on Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Becoulet, M.; Colas, L.; Gunn, J.; Ghendrih, Ph.; Becoulet, A. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Pecoul, S.; Heuraux, S. [Nancy-1 Univ., 54 (France). Lab. de Physique des Milieux Ionises

    2001-11-01

    The 2D edge plasma density distribution around ion cyclotron resonance heating (ICRH) antennae is studied experimentally and numerically in the tokamak Tore Supra (TS). A local density decrease in front of the loaded ICRH antenna ('pump-out' effect) is demonstrated by Langmuir probe measurements in a low recycling regime. An up-down asymmetry in the heat-flux and in the antenna erosion is also observed, and is associated with poloidal variations of the local density. These density redistributions are ascribed to an ExB convection process linked with RF-sheaths. To assess this interpretation, the 2D transport code CELLS was developed for modeling the density distribution near an antenna. The code takes into account perpendicular diffusion, parallel transport and convection in RF-sheath-driven potentials given by the 3D-antenna code ICANT. The strong density differences obtained in simulations reproduce up-down asymmetries of the heat fluxes. (authors)

  6. The control of plasma density profile in Tore Supra. Comparison of different fueling techniques; Controle du profil de densite dans le plasma de Tore Supra. Comparaison de differentes methodes d'alimentation en particules

    Energy Technology Data Exchange (ETDEWEB)

    Commaux, N

    2007-09-15

    The behaviour of a reactor-class plasma when fuelled using the existing techniques (gas puffing, supersonic molecular beam injection and pellet injection) is still very difficult to foresee. The present work has been initiated on Tore Supra in order to extrapolate the consequences of the different fuelling systems on ITER. Two main topics have been studied: the comparison of the plasma behaviour when fuelled using the different techniques at high Greenwald density fractions and the study of the homogenization following a pellet injection (main fuelling technique for ITER burning plasmas). The experiments at high Greenwald density fractions performed on Tore Supra showed that the plasma behaviour is very dependent on the fuelling method. The plasma energy confinement is following the scaling laws determined at low density when fuelled using pellet injection. which is better than for gas puffing and SMBI. both inducing a significant confinement loss. This behaviour is nor related to a transport modification: the ratio between effective diffusion and convection is similar to the pellet case. The difference between these shots is related only to the position of the matter source (at the edge for gas and close to the center for pellets). The study concerning the homogenization phenomena following a pellet injection aims mainly to study the {nabla}B-drift effect that expels the mater deposited by a pellet toward the low field side. A new phenomenon. which appears to be particularly important for the {nabla}B-drift during low field side injections. was then discovered: the influence of magnetic surfaces with an integer-valued safety factor (q). When the mater drifting toward low field side crosses an integer q surface. it experiences an important braking effect which stops the drift motion. It implies that the pellet material is mainly deposited on the last integer q surface crossed by the pellet during its injection. This study allows also to determine that the {nabla

  7. Tornado hazard communication disparities among Spanish-speaking individuals in an English-speaking community.

    Science.gov (United States)

    Ahlborn, Leslie; Franc, Jeffrey Michael

    2012-02-01

    The state of Oklahoma, known for destructive tornados, has a native Spanish-speaking (NSS) population of approximately 180,241, of which 50% report being able to speak English "very well" (US Census Bureau). With almost 50% of these native Spanish-speaking persons being limited English proficient (LEP), their reception of tornado hazard communications may be restricted. This study conducted in northeast Oklahoma (USA) evaluates the association between native language and receiving tornado hazard communications. This study was a cross-sectional survey conducted among a convenience sample of NSS and native English-speaking (NES) adults at Xavier Clinic and St. Francis Trauma Emergency Center in Tulsa, OK, USA from September 2009 through December 2009. Of the 82 surveys administered, 80 were returned, with 40 NES and 40 NSS participants. A scoring system (Severe Weather Information Reception (SWIR)) was developed to quantify reception of hazard information among the study participants (1-3 points=poor reception, 4-5=adequate reception, 6-8=excellent reception). Pearson's chi-squared test was used to calculate differences between groups with Yates' continuity correction applied where appropriate, and SWIR scores were analyzed using ANOVA. P-valuestornado siren. NSS were less likely to have Internet access (Ptornado warning reception between NSS and NES. Poor English proficiency was noted to be 75% among NSS, which is approximately 25% more than estimated by the US Census Bureau. This study demonstrates a need for emergency managers to recognize when appropriate and overcome communication disparities among limited English proficient populations.

  8. Shielding study of a fusion machine. Elaboration of a global shielding calculation scheme for the Tokamak tore Supra

    International Nuclear Information System (INIS)

    Diop, C.M'B.

    1984-01-01

    This thesis presents a global shielding calculation scheme for neutron and gamma rays arising from the Tokamak TORE SUPRA fusion device, in which a deuterium plasma is used. To study the shield parameters we have elabored a important chaining of neutron and gamma transport codes, TRIPOLI, ANISN, MERCURE 4, allowing to evaluate the radial and skyshine components of the dose rate behind the concrete shield. The study of thermonuclear neutron activation is fundamental to define a tokamak exploitation strategy. For this, two formalisme have been developed. They are based on a modelization of the activation reaction rates according to TRIPOLI, ANISN, and MERCURE 4 codes capabilities. The first one calculates, in one dimensional geometry, the desactivation gamma dose rate inside the vacuum chamber. The second one is a tridimensional model which determines the spatial variation of the gamma dose rate in the machine room. The problem of the existence of runaway electrons and associated secondaries radiations, bremsstrahlung gamma rays particularly, is approched. The results which are presented have contributed to define the parameters of the concrete shield and a strategy for TORE SUPRA Tokamak exploitation [fr

  9. Interplay between edge and outer core fluctuations in the tokamak Tore Supra

    International Nuclear Information System (INIS)

    Fenzi, C.; Garbet, X.; Capes, H.; Devynck, P.; Laviron, C.; Truc, A.; Gervais, F.; Hennequin, P.; Quemeneur, A.

    2000-01-01

    In the tokamak Tore Supra, when a poloidally and toroidally localized limiter, called a modular limiter, is introduced into the lower part of the scrape-off layer, density fluctuations located in the vicinity of this limiter present a specific feature with the appearance of a new spectral pattern in the associated frequency spectrum. This leads to a strong up-down asymmetry observed in both the plasma edge and the plasma outer core, with a maximum level of turbulence at the bottom of the plasma. The observed asymmetry characteristics show that magnetic connection lengths play a critical role here and that the limiter configuration has some effect on the outer core turbulence. (author)

  10. A concentrated outbreak of tornadoes, downbursts and microbursts, and implications regarding vortex classification

    Science.gov (United States)

    Forbes, G. S.; Wakimoto, R. M.

    1983-01-01

    A remarkable case of severe weather occurred near Springfield, Illinois on 6 August 1977. Aerial and ground surveys revealed that 17 cyclonic vortices, an anticyclonic vortex, 10 downbursts and 19 microbursts occurred in a limited (20 km x 40 km) area, associated with a bow-shaped radar echo. About half of the vortices appeared to have occurred along a gust front. Some of the others appear to have occurred within the circulation of a mesocyclone accompanying the bow echo, but these vortices seem to have developed specifically in response to localized boundary-layer vorticity generation associated with horizontal and vertical wind shears on the periphery of microbursts. Some of these vortices, and other destructive vortices in the literature, do not qualify as tornadoes as defined in the Glossary of Meteorology. A more pragmatic definition of a tornado is suggested.

  11. Observation of gravity waves during the extreme tornado outbreak of 3 April 1974

    Science.gov (United States)

    Hung, R. J.; Phan, T.; Smith, R. E.

    1978-01-01

    A continuous wave-spectrum high-frequency radiowave Doppler sounder array was used to observe upper-atmospheric disturbances during an extreme tornado outbreak. The observations indicated that gravity waves with two harmonic wave periods were detected at the F-region ionospheric height. Using a group ray path computational technique, the observed gravity waves were traced in order to locate potential sources. The signals were apparently excited 1-3 hours before tornado touchdown. Reverse ray tracing indicated that the wave source was located at the aurora zone with a Kp index of 6 at the time of wave excitation. The summation of the 24-hour Kp index for the day was 36. The results agree with existing theories (Testud, 1970; Titheridge, 1971; Kato, 1976) for the excitation of large-scale traveling ionospheric disturbances associated with geomagnetic activity in the aurora zone.

  12. Forest structure following tornado damage and salvage logging in northern Maine, USA

    Science.gov (United States)

    Shawn Fraver; Kevin J. Dodds; Laura S. Kenefic; Rick Morrill; Robert S. Seymour; Eben Sypitkowski

    2017-01-01

    Understanding forest structural changes resulting from postdisturbance management practices such as salvage logging is critical for predicting forest recovery and developing appropriate management strategies. In 2013, a tornado and subsequent salvage operations in northern Maine, USA, created three conditions (i.e., treatments) with contrasting forest structure:...

  13. Observation of the m = 1 mode by microwave transmission measurements in the Tore Supra tokamak

    International Nuclear Information System (INIS)

    Giruzzi, G.; Segui, J.L.; Pecquet, A.L.; Gil, C.

    1991-06-01

    Microwave transmission measurements in the Tore Supra tokamak exhibit low-frequency oscillations of the transmitted power, associated to the presence of a saturated m = 1, n = 1 mode, as observed by soft X-ray diagnostics. It is shown that these oscillations are related to refraction effects, and specifically to modulations of the electron density profile due to a rotating magnetic island. An analytical solution of the ray equations in the presence of a rotating density perturbation is found, explaining the frequency spectrum of the oscillations

  14. Tornado missile risk analysis. Topical report No. 1

    International Nuclear Information System (INIS)

    Dunn, W.L.; Lew, S.T.; Davis, R.L.; Hsu, J.C.; McConnell, B.S.

    1976-01-01

    Literature reviews, preliminary models, methodology descriptions, and general progress appraisal corresponding to the first 12 weeks of the research and approximately 14% of the budget expenditures are presented. Consequently, much of the methodology discussed in the various tasks is tentative and dependent upon further investigation as noted. The objective of this project is to develop a probabilistic formalism for characterizing the effects of the tornado generated missiles on the plant safety. The state-of-the-art nnd the R/D efforts needed to accomplish the stated objective are summarized

  15. Water Leak Localisation and Recovery in Tore Supra

    International Nuclear Information System (INIS)

    Martinez, A.; Samaille, F.; Chantant, M.; Hatchressian, J.-C.

    2006-01-01

    For almost 20 years, Tore Supra (TS) Tokamak uses water as a coolant for its plasma facing and in-vessels components. It can be considered as ITER relevant on this particular aspect. During plasma operation in TS, the water inlet temperature and outlet pressure are 120 o C and 2.4 MPa respectively, while baking is performed at 200 o C and 2 Mpa. It happened, that unexpected localized power deposits damaged in-vessels components leading to more or less large water leaks. In order to protect the vacuum vessel from over-pressurisation in case of large water leaks and to avoid the release of eventual activated materials, a pressure suppression system, composed of two rupture disks and a relief pipe header, has been designed. In the event of smaller leaks, the issue for Tore Supra operations is to apply methods capable of detecting and localising leaking water cooling circuits inside the vacuum vessel within an acceptable time. For this purpose, drainage and drying systems have been designed and manufactured to evacuate completely the water in the components and vacuum vessel, facilitating, in that way, leak testing procedure of the components. A new system allows the localization of the leaky circuit remotely by using the cooling loops monitoring system. The sub-circuits can be selected, isolated and de pressurized by the operator. Simultaneously the vacuum is monitored in the vessel and analyzed with a mass spectrometer. The water resulting from the steam condensation in the cold parts of the vacuum vessel is pumped by a new specific vacuum system in the lower parts of the machine and stored in tanks to avoid dissipation of activated products in the environment. Filters are implemented on the outlets lines of the pumps. The in-vessels components fed by the upper part of the cooling loop are connected in parallel and the water inlets and outlets are located on top of the machine, so some difficulties were encountered to drain-off completely this components. Presently

  16. Proposal for evaluation methodology on impact resistant performance and construction method of tornado missile protection net structure

    International Nuclear Information System (INIS)

    Namba, Kosuke; Shirai, Koji

    2014-01-01

    In nuclear power plants, the necessity of the Tornado Missile Protection Structure is becoming a technical key issue. Utilization of the net structure seems to be one of the realistic counter measures from the point of the view of the mitigation wind and seismic loads. However, the methodology for the selection of the net suitable materials, the energy absorption design method and the construction method are not sufficiently established. In this report, three materials (high-strength metal mesh, super strong polyethylene fiber net and steel grating) were selected for the candidate material and the material screening tests, the energy absorption tests by free drop test using the heavy weight and the impact tests with the small diameter missile. As a result, high-strength metal mesh was selected as a suitable material for tornado missile protection net structure. Moreover, the construction method to obtain the good energy absorption performance of the material and the practical design method to estimate the energy absorption of the high-strength metal mesh under tornado missile impact load were proposed. (author)

  17. Experimental demonstration of synergy between electron cyclotron and lower hybrid current drive on Tore Supra

    International Nuclear Information System (INIS)

    Artaud, J.F.; Giruzzi, G.; Dumont, R.J.; Imbeaux, F.; Bibet, P.; Bouquey, F.; Clary, J.; Ekedahl, A.; Hoang, G.T.; Lennholm, M.; Magne, R.; Segui, J.L.

    2004-01-01

    Non-inductive current drive (CD) has two main applications in tokamaks: sustainment of a substantial fraction of the toroidal plasma current necessary for the plasma confinement and control of the plasma stability and transport properties by appropriate shaping of the current density profile. For the first kind of applications, lower hybrid (LH) waves are known to provide the highest efficiency (defined as the ratio of the driven current to the injected wave power), although with limited control capability. Conversely, electron cyclotron (EC) waves drive highly localized currents, and are therefore particularly suited for control purposes, but their CD efficiency is much lower than that of LH waves (typically, an order of magnitude in present day experiments). Various calculations have demonstrated an interesting property: the current driven by the simultaneous use of the two waves, I(LH+EC), can be significantly larger than the sum I(LH)+I(EC) of the currents separately driven by the two waves in the same plasma conditions. This property, called synergy effect. The peculiar experimental conditions attainable on the Tore Supra tokamak have allowed the first experimental demonstration of the synergy between EC and LH current drive. The significant improvement of the electron cyclotron current drive (ECCD) efficiency in the presence of low hybrid current drive (LHCD), predicted by kinetic theory and confirmed by stationary experiments on Tore Supra, opens up the possibility of using ECCD as an efficient current profile control tool in LHCD plasmas

  18. Twitter as a Potential Disaster Risk Reduction Tool. Part III: Evaluating Variables that Promoted Regional Twitter Use for At-risk Populations During the 2013 Hattiesburg F4 Tornado.

    Science.gov (United States)

    Cooper, Guy Paul; Yeager, Violet; Burkle, Frederick M; Subbarao, Italo

    2015-06-29

    Study goals attempt to identify the variables most commonly associated with successful tweeted messages and determine which variables have the most influence in promoting exponential dissemination of information (viral spreading of the message) and trending (becoming popular) in the given disaster affected region. Part II describes the detailed extraction and triangulation filtration methodological approach to acquiring twitter data for the 2013 Hattiesburg Tornado. The data was then divided into two 48 hour windows before and after the tornado impact with a 2 hour pre-tornado buffer to capture tweets just prior to impact. Criteria-based analysis was completed for Tweets and users. The top 100 pre-Tornado and post-Tornado retweeted users were compared to establish the variability among the top retweeted users during the 4 day span.  Pre-Tornado variables that were correlated to higher retweeted rates include total user tweets (0.324), and total times message retweeted (0.530).  Post-Tornado variables that were correlated to higher retweeted rates include total hashtags in a retweet (0.538) and hashtags #Tornado (0.378) and #Hattiesburg (0.254). Overall hashtags usage significantly increased during the storm. Pre-storm there were 5,763 tweets with a hashtag and post-storm there was 13,598 using hashtags. Twitter's unique features allow it to be considered a unique social media tool applicable for emergency managers and public health officials for rapid and accurate two way communication.  Additionally, understanding how variables can be properly manipulated plays a key role in understanding how to use this social media platform for effective, accurate, and rapid mass information communication.

  19. Environmental risk perception from visual cues: the psychophysics of tornado risk perception

    Science.gov (United States)

    Dewitt, Barry; Fischhoff, Baruch; Davis, Alexander; Broomell, Stephen B.

    2015-12-01

    Lay judgments of environmental risks are central to both immediate decisions (e.g., taking shelter from a storm) and long-term ones (e.g., building in locations subject to storm surges). Using methods from quantitative psychology, we provide a general approach to studying lay perceptions of environmental risks. As a first application of these methods, we investigate a setting where lay decisions have not taken full advantage of advances in natural science understanding: tornado forecasts in the US and Canada. Because official forecasts are imperfect, members of the public must often evaluate the risks on their own, by checking environmental cues (such as cloud formations) before deciding whether to take protective action. We study lay perceptions of cloud formations, demonstrating an approach that could be applied to other environmental judgments. We use signal detection theory to analyse how well people can distinguish tornadic from non-tornadic clouds, and multidimensional scaling to determine how people make these judgments. We find that participants (N = 400 recruited from Amazon Mechanical Turk) have heuristics that generally serve them well, helping participants to separate tornadic from non-tornadic clouds, but which also lead them to misjudge the tornado risk of certain cloud types. The signal detection task revealed confusion regarding shelf clouds, mammatus clouds, and clouds with upper- and mid-level tornadic features, which the multidimensional scaling task suggested was the result of participants focusing on the darkness of the weather scene and the ease of discerning its features. We recommend procedures for training (e.g., for storm spotters) and communications (e.g., tornado warnings) that will reduce systematic misclassifications of tornadicity arising from observers’ reliance on otherwise useful heuristics.

  20. Java graphical user interface for the supervision of Tore Supra

    International Nuclear Information System (INIS)

    Utzel, Nadine; Guillerminet, Bernard; Leluyer, Mireille; Moulin, Daniele

    2002-01-01

    The graphical user interface (GUI) for the supervision of Tore Supra is intended to supervise the start-up and the shut-down of the installation, to control general state (state of all diagnostics, state of the system and network) and to follow the pulse sequence. Implementation of a new multi-platform, modular GUI for Tore Supra is in progress. This provides not only a simpler, more structured view for the non-specialist user, but also is open-ended and adaptable to a wide variety of uses. The actual implementation of a GUI is a question of user-ergonomics. Hence, a user-directed study in 2000 produced a specification for the interface. The information is treated with a hierarchical order. At the top level, only the global state of the supervised elements appears, i.e. the general state of every diagnostics, the pulse sequence, the safety systems. If a problem occurs, the operator has access to the lower level detailed state of the concerned element, simply with a double-click. An event log also helps the operator to analyse the chronology of the alarms arising during the pulse. Although the GUI is mainly used in the control room on X terminals under Unix, it should also be accessible via a portable PC for the purpose of maintenance, or directly from any office to see how the physics program is progressing. The choice of Java, multi-platform object programming language was thus adopted with access via any web browser. The modularity of the GUI is made possible by a distributed architecture (remote method invocation) between the graphic client and different servers: one for the diagnostics and the sequence, one for the system and the network and one for the configuration database. All the components interact with each other in a very simple and standard way. This distributed architecture allows the progressive set up of the new interface. The first step, being produced for mid-2001 is the GUI for the supervision of diagnostics. This prototype will help us to