WorldWideScience

Sample records for mass absorption coefficients

  1. Mass: Fortran program for calculating mass-absorption coefficients

    Nielsen, Aa.; Svane Petersen, T.

    1980-01-01

    Determinations of mass-absorption coefficients in the x-ray analysis of trace elements are an important and time consuming part of the arithmetic calculation. In the course of time different metods have been used. The program MASS calculates the mass-absorption coefficients from a given major element analysis at the x-ray wavelengths normally used in trace element determinations and lists the chemical analysis and the mass-absorption coefficients. The program is coded in FORTRAN IV, and is operational on the IBM 370/165 computer, on the UNIVAC 1110 and on PDP 11/05. (author)

  2. Restricted mass energy absorption coefficients for use in dosimetry

    Brahme, A.

    1977-02-01

    When matter is irradiated by a photon beam the fraction of energy absorbed locally in some region Rsub(Δ) (where the size of the region Rsub(Δ) is related to the range of secondary electrons of some restriction energy Δ) is expressed by the restricted mass energy absorption coefficient. In this paper an example is given of how restricted mass energy absorption coefficients can be calculated from existing differential photon interaction cross sections. Some applications of restricted mass absorption coefficients in dosimetry are also given. (B.D.)

  3. A method for determination mass absorption coefficient of gamma rays by Compton scattering

    El Abd, A.

    2014-01-01

    A method was proposed for determination mass absorption coefficient of gamma rays for compounds, alloys and mixtures. It is based on simulating interaction processes of gamma rays with target elements having atomic numbers from Z=1 to Z=92 using the MCSHAPE software. Intensities of Compton scattered gamma rays at saturation thicknesses and at a scattering angle of 90° were calculated for incident gamma rays of different energies. The obtained results showed that the intensity of Compton scattered gamma rays at saturations and mass absorption coefficients can be described by mathematical formulas. These were used to determine mass absorption coefficients for compound, alloys and mixtures with the knowledge of their Compton scattered intensities. The method was tested by calculating mass absorption coefficients for some compounds, alloys and mixtures. There is a good agreement between obtained results and calculated ones using WinXom software. The advantages and limitations of the method were discussed. - Highlights: • Compton scattering of γ−rays was used for determining mass absorption coefficient. • Scattered intensities were determined by the MCSHAPE software. • Mass absorption coefficients were determined for some compounds, mixtures and alloys. • Mass absorption coefficients were calculated by Winxcom software. • Good agreements were found between determined and calculated results

  4. A method for determination mass absorption coefficient of gamma rays by Compton scattering.

    El Abd, A

    2014-12-01

    A method was proposed for determination mass absorption coefficient of gamma rays for compounds, alloys and mixtures. It is based on simulating interaction processes of gamma rays with target elements having atomic numbers from Z=1 to Z=92 using the MCSHAPE software. Intensities of Compton scattered gamma rays at saturation thicknesses and at a scattering angle of 90° were calculated for incident gamma rays of different energies. The obtained results showed that the intensity of Compton scattered gamma rays at saturations and mass absorption coefficients can be described by mathematical formulas. These were used to determine mass absorption coefficients for compound, alloys and mixtures with the knowledge of their Compton scattered intensities. The method was tested by calculating mass absorption coefficients for some compounds, alloys and mixtures. There is a good agreement between obtained results and calculated ones using WinXom software. The advantages and limitations of the method were discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Mass attenuation coefficient of chromium and manganese compounds around absorption edge.

    Sharanabasappa; Kaginelli, S B; Kerur, B R; Anilkumar, S; Hanumaiah, B

    2009-01-01

    The total mass attenuation coefficient for Potassium dichromate, Potassium chromate and Manganese acetate compounds are measured at different photon energies 5.895, 6.404, 6.490, 7.058, 8.041 and 14.390 keV using Fe-55, Co-57 and 241Am source with Copper target, radioactive sources. The photon intensity is analyzed using a high resolution HPGe detector system coupled to MCA under good geometrical arrangement. The obtained values of mass attenuation coefficient values are compared with theoretical values. This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 5-28%.

  6. Mass Absorption Coefficients At 661,6 keV Energy In Various Samples

    Suhariyono, Gatot; Bunawas

    2000-01-01

    Determination mass absorption coefficients (mum) at 661.6 keV energy in the samples various, such as lysine, coffee, chocolate, nutrisari, coconut oil, monosodium glutamate (MSG), tea, tin fish and the soil with experiment method has been carried out. The mum research was carried out in effort to give the measurement result of Cs-137 concentration that more accurate to the samples, because the sample density increases, mass absorption coefficients (mum) decreases. The mum correction on measurement of Cs-137 concentration in the samples various around between 0 and 13%, the highest is on the chocolate sample and the lowest is on the tin fish sample. Density of the samples decreases, the mum influence increases on the counting of Cs-137 concentration in the sample (Bq/kg)

  7. Mass absorption and mass energy transfer coefficients for 0.4-10 MeV gamma rays in elemental solids and gases

    Gurler, O. [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)], E-mail: ogurler@uludag.edu.tr; Oz, H. [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey); Gundogdu, O. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, GU2 7XX (United Kingdom)

    2009-01-15

    The mass energy absorption, the mass energy transfer and mass absorption coefficients have been widely used for problems and applications involving dose calculations. Direct measurements of the coefficients are difficult, and theoretical computations are usually employed. In this paper, analytical equations are presented for determining the mass energy transfer and mass absorption coefficients for gamma rays with an incident energy range between 0.4 and 10 MeV in nitrogen, silicon, carbon, copper and sodium iodide. The mass absorption and mass energy transfer coefficients for gamma rays were calculated, and the results obtained were compared with the values reported in the literature.

  8. Mass absorption and mass energy transfer coefficients for 0.4-10 MeV gamma rays in elemental solids and gases

    Gurler, O.; Oz, H.; Yalcin, S.; Gundogdu, O.

    2009-01-01

    The mass energy absorption, the mass energy transfer and mass absorption coefficients have been widely used for problems and applications involving dose calculations. Direct measurements of the coefficients are difficult, and theoretical computations are usually employed. In this paper, analytical equations are presented for determining the mass energy transfer and mass absorption coefficients for gamma rays with an incident energy range between 0.4 and 10 MeV in nitrogen, silicon, carbon, copper and sodium iodide. The mass absorption and mass energy transfer coefficients for gamma rays were calculated, and the results obtained were compared with the values reported in the literature

  9. Empirical formulae for mass attenuation and energy absorption coefficients from 1 keV to 20 MeV

    Manjunatha, H.C.; Sowmya, N.; Seenappa, L.; Sridhar, K.N.; Hanumantharayappa, C.

    2017-01-01

    Mass attenuation and energy absorption coefficients represents attenuation and absorption of X-rays and gamma rays in the material medium. A new empirical formula is proposed for mass attenuation and energy absorption coefficients in the region 1 < Z < 92 and from 1 keV to 20 MeV. The mass attenuation and energy absorption coefficients do not varies linearly with energy. We have performed the nonlinear regressions/nonlinear least square fittings and proposed the simple empirical relations between mass attenuation coefficients (μ/ρ) and mass energy absorption coefficients (μ en /ρ) and energy. We have compared the values produced by this formula with that of experiments. A good agreement of present formula with the experiments/previous models suggests that the present formulae could be used to evaluate mass attenuation and energy absorption coefficients in the region 1 < Z < 92. This formula is a model-independent formula and is the first of its kind that produces a mass attenuation and energy absorption coefficient values with the only simple input of energy for wide energy range 1 keV - 20 MeV in the atomic number region 1 < Z < 92. This formula is very much useful in the fields of radiation physics and dosimetry

  10. Prediction of mass absorption coefficients from inelastically scattered X-radiation for specimens of less than 'infinite thickness'

    Kieser, R.; Mulligan, T.J.

    1979-01-01

    An equation is developed which describes the X-ray scatter radiation from specimens of any thickness. This equation suggests that a specimen's mass absorption coefficient can be determined from its inelastically scattered X-radiation not only when the specimen is 'infinitely thick' but also when it is of 'intermediate thickness'. Measurements have been carried out with a standard energy-dispersive X-ray spectrometer on specimens of 'intermediate thickness'. Good agreement is obtained between the mass absorption coefficients that are calculated from the scattered radiation and those obtained on the basis of tabulated mass absorption coefficients for the elements. (author)

  11. Measurement of mass attenuation coefficients around the K absorption edge by parametric X-rays

    Tamura, Masaya; Akimoto, Tadashi; Aoki, Yohei; Ikeda, Jiro; Sato, Koichi; Fujita, Fumiyuki; Homma, Akira; Sawamura, Teruko; Narita, Masakuni

    2002-01-01

    When electrons at relativistic velocities pass through a crystal plate, such as silicon, photons are emitted around the Bragg angle for X-ray diffraction. This phenomenon is called parametric X-ray radiation (PXR). The monochromaticity and directivity of PXR are adequate and the energy can be changed continuously by rotating the crystal. This study measured the mass attenuation coefficient around the K-shell absorption edge of Nb, Zr and Mo as a PXR application of monochromatic hard X-ray radiation sources

  12. Measurement of mass attenuation coefficients around the K absorption edge by parametric X-rays

    Tamura, M; Aoki, Y; Ikeda, J; Sato, K; Fujita, F; Homma, A; Sawamura, T; Narita, M

    2002-01-01

    When electrons at relativistic velocities pass through a crystal plate, such as silicon, photons are emitted around the Bragg angle for X-ray diffraction. This phenomenon is called parametric X-ray radiation (PXR). The monochromaticity and directivity of PXR are adequate and the energy can be changed continuously by rotating the crystal. This study measured the mass attenuation coefficient around the K-shell absorption edge of Nb, Zr and Mo as a PXR application of monochromatic hard X-ray radiation sources.

  13. Stopping-power and mass energy-absorption coefficient ratios for Solid Water

    Ho, A.K.; Paliwal, B.R.

    1986-01-01

    The AAPM Task Group 21 protocol provides tables of ratios of average restricted stopping powers and ratios of mean energy-absorption coefficients for different materials. These values were based on the work of Cunningham and Schulz. We have calculated these quantities for Solid Water (manufactured by RMI), using the same x-ray spectra and method as that used by Cunningham and Schulz. These values should be useful to people who are using Solid Water for high-energy photon calibration

  14. On the uncertainties of photon mass energy-absorption coefficients and their ratios for radiation dosimetry

    Andreo, Pedro; Burns, David T.; Salvat, Francesc

    2012-04-01

    A systematic analysis of the available data has been carried out for mass energy-absorption coefficients and their ratios for air, graphite and water for photon energies between 1 keV and 2 MeV, using representative kilovoltage x-ray spectra for mammography and diagnostic radiology below 100 kV, and for 192Ir and 60Co gamma-ray spectra. The aim of this work was to establish ‘an envelope of uncertainty’ based on the spread of the available data. Type A uncertainties were determined from the results of Monte Carlo (MC) calculations with the PENELOPE and EGSnrc systems, yielding mean values for µen/ρ with a given statistical standard uncertainty. Type B estimates were based on two groupings. The first grouping consisted of MC calculations based on a similar implementation but using different data and/or approximations. The second grouping was formed by various datasets, obtained by different authors or methods using the same or different basic data, and with different implementations (analytical, MC-based, or a combination of the two); these datasets were the compilations of NIST, Hubbell, Johns-Cunningham, Attix and Higgins, plus MC calculations with PENELOPE and EGSnrc. The combined standard uncertainty, uc, for the µen/ρ values for the mammography x-ray spectra is 2.5%, decreasing gradually to 1.6% for kilovoltage x-ray spectra up to 100 kV. For 60Co and 192Ir, uc is approximately 0.1%. The Type B uncertainty analysis for the ratios of µen/ρ values includes four methods of analysis and concludes that for the present data the assumption that the data interval represents 95% confidence limits is a good compromise. For the mammography x-ray spectra, the combined standard uncertainties of (µen/ρ)graphite,air and (µen/ρ)graphite,water are 1.5%, and 0.5% for (µen/ρ)water,air, decreasing gradually down to uc = 0.1% for the three µen/ρ ratios for the gamma-ray spectra. The present estimates are shown to coincide well with those of Hubbell (1977 Rad. Res

  15. Photon mass energy absorption coefficients from 0.4 MeV to 10 MeV for silicon, carbon, copper and sodium iodide

    Oz, H.; Gurler, O.; Gultekin, A.; Yalcin, S.; Gundogdu, O.

    2006-01-01

    The absorption coefficients have been widely used for problems and applications involving dose calculations. Direct measurements of the coefficients are difficult, and theoretical computations are usually employed. In this paper, analytical equations are presented for determining the mass energy absorption coefficients for gamma rays with an incident energy range between 0.4 MeV and 10 MeV in silicon, carbon, copper and sodium iodide. The mass energy absorption coefficients for gamma rays were calculated, and the results obtained were compared with the values reported in the literature.

  16. Photon mass energy absorption coefficients from 0.4 MeV to 10 MeV for silicon, carbon, copper and sodium iodide

    Oz, H.; Gurler, O.; Gultekin, A. [Uludag University, Bursa (Turkmenistan); Yalcin, S. [Kastamonu University, Kastamonu (Turkmenistan); Gundogdu, O. [University of Surrey, Guildford (United Kingdom)

    2006-07-15

    The absorption coefficients have been widely used for problems and applications involving dose calculations. Direct measurements of the coefficients are difficult, and theoretical computations are usually employed. In this paper, analytical equations are presented for determining the mass energy absorption coefficients for gamma rays with an incident energy range between 0.4 MeV and 10 MeV in silicon, carbon, copper and sodium iodide. The mass energy absorption coefficients for gamma rays were calculated, and the results obtained were compared with the values reported in the literature.

  17. Doppler broadening and its contribution to Compton energy-absorption cross sections: An analysis of the Compton component in terms of mass-energy absorption coefficient

    Rao, D.V.; Takeda, T.; Itai, Y.; Akatsuka, T.; Cesareo, R.; Brunetti, A.; Gigante, G.E.

    2002-01-01

    Compton energy absorption cross sections are calculated using the formulas based on a relativistic impulse approximation to assess the contribution of Doppler broadening and to examine the Compton profile literature and explore what, if any, effect our knowledge of this line broadening has on the Compton component in terms of mass-energy absorption coefficient. Compton energy-absorption cross sections are evaluated for all elements, Z=1-100, and for photon energies 1 keV-100 MeV. Using these cross sections, the Compton component of the mass-energy absorption coefficient is derived in the energy region from 1 keV to 1 MeV for all the elements Z=1-100. The electron momentum prior to the scattering event should cause a Doppler broadening of the Compton line. The momentum resolution function is evaluated in terms of incident and scattered photon energy and scattering angle. The overall momentum resolution of each contribution is estimated for x-ray and γ-ray energies of experimental interest in the angular region 1 deg. -180 deg. . Also estimated is the Compton broadening using nonrelativistic formula in the angular region 1 deg. -180 deg., for 17.44, 22.1, 58.83, and 60 keV photons for a few elements (H, C, N, O, P, S, K, and Ca) of biological importance

  18. Doppler Broadening and its Contribution to Compton Energy-Absorption Cross Sections: An Analysis of the Compton Component in Terms of Mass-Energy Absorption Coefficient

    Rao, D. V.; Takeda, T.; Itai, Y.; Akatsuka, T.; Cesareo, R.; Brunetti, A.; Gigante, G. E.

    2002-09-01

    Compton energy absorption cross sections are calculated using the formulas based on a relativistic impulse approximation to assess the contribution of Doppler broadening and to examine the Compton profile literature and explore what, if any, effect our knowledge of this line broadening has on the Compton component in terms of mass-energy absorption coefficient. Compton energy-absorption cross sections are evaluated for all elements, Z=1-100, and for photon energies 1 keV-100 MeV. Using these cross sections, the Compton component of the mass-energy absorption coefficient is derived in the energy region from 1 keV to 1 MeV for all the elements Z=1-100. The electron momentum prior to the scattering event should cause a Doppler broadening of the Compton line. The momentum resolution function is evaluated in terms of incident and scattered photon energy and scattering angle. The overall momentum resolution of each contribution is estimated for x-ray and γ-ray energies of experimental interest in the angular region 1°-180°. Also estimated is the Compton broadening using nonrelativistic formula in the angular region 1°-180°, for 17.44, 22.1, 58.83, and 60 keV photons for a few elements (H, C, N, O, P, S, K, and Ca) of biological importance.

  19. Sabine absorption coefficients to random incidence absorption coefficients

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  20. Converting Sabine absorption coefficients to random incidence absorption coefficients

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  1. Determination of ash content of coal by mass absorption coefficient measurements at two X-ray energies

    Fookes, R.A.; Gravitis, V.L.; Watt, J.S.

    1977-01-01

    A method for determining the ash content of coal is proposed. It involves measurements proportional to mass absorption coefficients of coal at two X-ray energies. These measurements can be made using X-ray transmission or scatter techniques. Calculations based on transmission of narrow beams of X-rays have shown that ash can be determined to about 1wt%(1 sigma) in coal of widely varying ash content and composition. Experimentally, ash content was determined to 0.67wt% by transmission techniques and 1.0wt% by backscatter techniques in coal samples from the Bulli seam, NSW, Australia, having ash in the range 11-34wt%. For samples with a much wider range of coal composition (7-53wt% ash and 0-25wt% iron in the ash), ash content was determined by backscatter measurements to 1.62wt%. The method produced ash determinations at least as accurate as those produced by the established technique which compensates for variation in iron content of the ash by X-ray fluorescence analysis for iron. Compared with the established technique, it has the advantage of averaging analysis over much larger volumes of coal, but the disadvantage that much more precise measurements of X-ray intensities are required. (author)

  2. The selection of stopping power and mass energy absorption coefficient data for the HPA Code of Practice for dosimetry

    Williams, P.C.

    1985-01-01

    The author draws attention to a discussion by Cunningham and Schultz (1984) which states that, 'with the exception of the NACP and AAPM protocols, the selection of stopping power and energy absorption coefficient ratios has been based upon only the stated accelerating potential of the accelerator', and points out that the HPA Revised Code of Practice should be added to these exceptions. In calculating the HPA's new Csub(lambda) values, a similar, but not identical, approach was taken in order to determine the stopping power and absorption coefficient ratios at each radiation quality. It was recognised that the approximation of a spectrum to a monoenergetic spectrum of between 0.4 and 0.45 of the maximum energy, as had been done in calculating the values, given in ICRU Report 14, was incorrect. (U.K.)

  3. Measurement of X-ray mass attenuation coefficient of nickel around the K-edge using synchrotron radiation based X-ray absorption study

    Roy, Bunty Rani; Rajput, Parasmani; Jha, S.N.; Nageswara Rao, A.S.

    2015-01-01

    The work presents the X-ray absorption fine structure (XAFS) technique for measuring the X-ray mass attenuation coefficient of nickel metal foil in the X-ray energy range of 8271.2–8849.4 eV using scanning XAFS beam line (BL-09) at Indus-2 synchrotron radiation source facility, Raja Ramanna Centre for Advanced Technology (RRCAT) at Indore, India. The result represents the X-ray mass attenuation coefficient data for 0.02 mm thick Ni metal foil in the XAFS region of Ni K-edge. However, the results are compared to theoretical values using X-COM. There is a maximum deviation which is found exactly near the K-edge jump and decreases as we move away from the absorption edge. Oscillatory structure appears just above the observed absorption edge i.e., 8348.7 eV and is confined to around 250 eV above the edge. - Highlights: • Mass attenuation coefficient measurements of nickel using synchrotron radiation. • The measurements were taken exactly near the Ni K-edge at an energy step of 1 eV. • A maximum deviation is found near the K-edge

  4. Determination of the Mass Absorption Coefficient in Two-Layer Ti/V and V/Ti Thin Film Systems by the X-Ray Fluorescence Method

    Mashin, N. I.; Chernyaeva, E. A.; Tumanova, A. N.; Gafarova, L. M.

    2016-03-01

    A new XRF procedure for the determination of the mass absorption coefficient in thin film Ti/V and V/Ti two-layer systems has been proposed. The procedure uses easy-to-make thin-film layers of sputtered titanium and vanadium on a polymer film substrate. Correction coefficients have been calculated that take into account attenuation of primary radiation of the X-ray tube, as well as attenuation of the spectral line of the bottom layer element in the top layer.

  5. Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.

    Buhr, H; Büermann, L; Gerlach, M; Krumrey, M; Rabus, H

    2012-12-21

    For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron storage ring BESSY II both the radiant power and the fraction of power deposited in dry air were measured using a cryogenic electrical substitution radiometer and a free air ionization chamber, respectively. The measured absorption coefficients were compared with state-of-the art calculations and showed an average deviation of 2% from calculations by Seltzer. However, they agree within 1% with data calculated earlier by Hubbell. In the course of this work, an improvement of the data analysis of a previous experimental determination of the mass energy-absorption coefficient of air in the range of 3 to 10 keV was found to be possible and corrected values of this preceding study are given.

  6. Mass energy-absorption coefficients and average atomic energy-absorption cross-sections for amino acids in the energy range 0.122-1.330 MeV

    More, Chaitali V., E-mail: chaitalimore89@gmail.com; Lokhande, Rajkumar M.; Pawar, Pravina P., E-mail: pravinapawar4@gmail.com [Department of physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad 431004 (India)

    2016-05-06

    Mass attenuation coefficients of amino acids such as n-acetyl-l-tryptophan, n-acetyl-l-tyrosine and d-tryptophan were measured in the energy range 0.122-1.330 MeV. NaI (Tl) scintillation detection system was used to detect gamma rays with a resolution of 8.2% at 0.662 MeV. The measured attenuation coefficient values were then used to determine the mass energy-absorption coefficients (σ{sub a,en}) and average atomic energy-absorption cross sections (μ{sub en}/ρ) of the amino acids. Theoretical values were calculated based on XCOM data. Theoretical and experimental values are found to be in good agreement.

  7. Determination of the X-ray mass absorption coefficient by measurement of the intensity of AgKα Compton scattered radiation

    Franzini, M.; Leoni, L.; Saitta, M.

    1976-01-01

    By utilizing a reflection geometry, an accurate mass absorption coefficient of a sample can be determined by measuring the Ag Kα Compton intensity. Intensities of Ag Kα Compton scattered radiation have been collected by using either the usual reflection geometry of a Philips PW 1450 automatic x-ray spectrometer or a more refined reflection geometry, achieved on a Philips PW 1540/10A manual x-ray spectrometer. The experimental results have shown that the relationship between the Ag Kα Compton intensity and the mass absorption is a logarithmic function. The experimental results are not in agreement with those reported in literature, but a theoretical explanation to account for this fact has not been achieved as yet. (author)

  8. Mass attenuation and mass energy absorption coefficients for 10 keV to 10 MeV photons; Coefficients d'attenuation massique et d'absorption massique en energie pour les photons de 10 keV a 10 MeV

    Joffre, H; Pages, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    In this report are given the elements allowing the definition of the values of mass attenuation coefficients and mass energy absorption coefficients for some elements and mixtures, necessary for the study of tissue equivalent materials, for photons in the energy range 10 keV to 10 MeV. After a short reminding of the definitions of the two coefficients, follows, in table form, a compilation of these coefficients, as a function of energy, for simple elements, for certain mineral compounds, organic compounds, gases and particularly of soft tissues. (author) [French] Dans ce rapport, sont donnes les elements permettant de determiner les valeurs des coefficients d'attenuation massique et d'absorption massique en energie pour certains elements et melanges necessaires a l'etude des materiaux equivalents aux tissus pour les photons dans le domaine d'energie allant de 10 keV a 10 MeV. Apres un bref rappel des definitions des deux coefficients, suit, sous forme de tableaux, un recueil de ces coefficients, en fonction de l'energie, pour les elements simples, certains composes mineraux, composes organiques, gaz, et, particulierement, pour les tissus mous. (auteur)

  9. Studies on absorption coefficient near edge of multi elements

    Eisa, M.H.; Shen, H.; Yao, H.Y.; Mi, Y.; Zhou, Z.Y.; Hu, T.D.; Xie, Y.N.

    2005-01-01

    X-ray absorption near edge structure (XANES) was used to study the near edge mass-absorption coefficients of seven elements, such as, Ti, V, Fe, Co, Ni, Cu and Zn. It is well known that, on the near edge absorption of element, when incident X-ray a few eV change can make the absorption coefficient an order magnitude alteration. So that, there are only a few points mass-absorption coefficient at the near edge absorption and that always average value in published table. Our results showed a wide range of data, the total measured data of mass-absorption coefficient of the seven elements was about 505. The investigation confirmed that XANES is useful technique for multi-element absorption coefficient measurement. Details of experimental methods and results are given and discussed. The experimental work has been performed at Beijing Synchrotron Radiation Facility. The measured values were compared with the published data. Good agreement between experimental results and published data is obtained

  10. Studies on absorption coefficient near edge of multi elements

    Eisa, M. H.; Shen, H.; Yao, H. Y.; Mi, Y.; Zhou, Z. Y.; Hu, T. D.; Xie, Y. N.

    2005-12-01

    X-ray absorption near edge structure (XANES) was used to study the near edge mass-absorption coefficients of seven elements, such as, Ti, V, Fe, Co, Ni, Cu and Zn. It is well known that, on the near edge absorption of element, when incident X-ray a few eV change can make the absorption coefficient an order magnitude alteration. So that, there are only a few points mass-absorption coefficient at the near edge absorption and that always average value in published table. Our results showed a wide range of data, the total measured data of mass-absorption coefficient of the seven elements was about 505. The investigation confirmed that XANES is useful technique for multi-element absorption coefficient measurement. Details of experimental methods and results are given and discussed. The experimental work has been performed at Beijing Synchrotron Radiation Facility. The measured values were compared with the published data. Good agreement between experimental results and published data is obtained.

  11. Absorption coefficients of silicon: A theoretical treatment

    Tsai, Chin-Yi

    2018-05-01

    A theoretical model with explicit formulas for calculating the optical absorption and gain coefficients of silicon is presented. It incorporates direct and indirect interband transitions and considers the effects of occupied/unoccupied carrier states. The indirect interband transition is calculated from the second-order time-independent perturbation theory of quantum mechanics by incorporating all eight possible routes of absorption or emission of photons and phonons. Absorption coefficients of silicon are calculated from these formulas. The agreements and discrepancies among the calculated results, the Rajkanan-Singh-Shewchun (RSS) formula, and Green's data are investigated and discussed. For example, the RSS formula tends to overestimate the contributions of indirect transitions for cases with high photon energy. The results show that the state occupied/unoccupied effect is almost negligible for silicon absorption coefficients up to the onset of the optical gain condition where the energy separation of Quasi-Femi levels between electrons and holes is larger than the band-gap energy. The usefulness of using the physics-based formulas, rather than semi-empirical fitting ones, for absorption coefficients in theoretical studies of photovoltaic devices is also discussed.

  12. Experimental methodology for obtaining sound absorption coefficients

    Carlos A. Macía M

    2011-07-01

    Full Text Available Objective: the authors propose a new methodology for estimating sound absorption coefficients using genetic algorithms. Methodology: sound waves are generated and conducted along a rectangular silencer. The waves are then attenuated by the absorbing material covering the silencer’s walls. The attenuated sound pressure level is used in a genetic algorithm-based search to find the parameters of the proposed attenuation expressions that include geometric factors, the wavelength and the absorption coefficient. Results: a variety of adjusted mathematical models were found that make it possible to estimate the absorption coefficients based on the characteristics of a rectangular silencer used for measuring the attenuation of the noise that passes through it. Conclusions: this methodology makes it possible to obtain the absorption coefficients of new materials in a cheap and simple manner. Although these coefficients might be slightly different from those obtained through other methodologies, they provide solutions within the engineering accuracy ranges that are used for designing noise control systems.

  13. Reproducibility of The Random Incidence Absorption Coefficient Converted From the Sabine Absorption Coefficient

    Jeong, Cheol-Ho; Chang, Ji-ho

    2015-01-01

    largely depending on the test room. Several conversion methods for porous absorbers from the Sabine absorption coefficient to the random incidence absorption coefficient were suggested by considering the finite size of a test specimen and non-uniformly incident energy onto the specimen, which turned out...... resistivity optimization outperforms the surface impedance optimization in terms of the reproducibility....

  14. Low-temperature MIR to submillimeter mass absorption coefficient of interstellar dust analogues. II. Mg and Fe-rich amorphous silicates

    Demyk, K.; Meny, C.; Leroux, H.; Depecker, C.; Brubach, J.-B.; Roy, P.; Nayral, C.; Ojo, W.-S.; Delpech, F.

    2017-10-01

    Context. To model the cold dust emission observed in the diffuse interstellar medium, in dense molecular clouds or in cold clumps that could eventually form new stars, it is mandatory to know the physical and spectroscopic properties of this dust and to understand its emission. Aims: This work is a continuation of previous studies aiming at providing astronomers with spectroscopic data of realistic cosmic dust analogues for the interpretation of observations. The aim of the present work is to extend the range of studied analogues to iron-rich silicate dust analogues. Methods: Ferromagnesium amorphous silicate dust analogues were produced by a sol-gel method with a mean composition close to Mg1-xFexSiO3 with x = 0.1, 0.2, 0.3, 0.4. Part of each sample was annealed at 500 °C for two hours in a reducing atmosphere to modify the oxidation state of iron. We have measured the mass absorption coefficient (MAC) of these eight ferromagnesium amorphous silicate dust analogues in the spectral domain 30-1000 μm for grain temperature in the range 10-300 K and at room temperature in the 5-40 μm range. Results: The MAC of ferromagnesium samples behaves in the same way as the MAC of pure Mg-rich amorphous silicate samples. In the 30-300 K range, the MAC increases with increasing grain temperature whereas in the range 10-30 K, we do not see any change of the MAC. The MAC cannot be described by a single power law in λ- β. The MAC of the samples does not show any clear trend with the iron content. However the annealing process has, on average, an effect on the MAC that we explain by the evolution of the structure of the samples induced by the processing. The MAC of all the samples is much higher than the MAC calculated by dust models. Conclusions: The complex behavior of the MAC of amorphous silicates with wavelength and temperature is observed whatever the exact silicate composition (Mg vs. Fe amount). It is a universal characteristic of amorphous materials, and therefore of

  15. Regularity of the Interband Light Absorption Coefficient

    In this paper we consider the interband light absorption coefficient (ILAC), in a symmetric form, in the case of random operators on the -dimensional lattice. We show that the symmetrized version of ILAC is either continuous or has a component which has the same modulus of continuity as the density of states.

  16. K-shell absorption jump factors and jump ratios in elements between Tm ( Z = 69) and Os ( Z = 76) derived from new mass attenuation coefficient measurements

    Kaya, Necati; Tıraşoğlu, Engin; Apaydın, Gökhan; Aylıkcı, Volkan; Cengiz, Erhan

    2007-08-01

    The K-shell absorption jump factors and jump ratios were derived from new mass attenuation coefficients measured using an energy dispersive X-ray fluorescence (EDXRF) spectrometer for Tm, Yb elements being Tm 2O 3, Yb 2O 3 compounds and pure Lu, Hf, Ta, W, Re and Os. The measurements, in the region 56-77 keV, were done in a transmission geometry utilizing the K α1 , K α2 , K β1 and K β2 X- rays from different secondary source targets (Yb, Ta, Os, W, Re and Ir, etc.) excited by the 123.6 keV γ-photons from an 57Co annular source and detected by an Ultra-LEGe solid state detector with a resolution of 150 eV at 5.9 keV. Experimental results have been compared with theoretically calculated values. The measured values of Tm, Yb, Lu, Hf, Ta, W, Re and Os are reported here for the first time.

  17. K-shell absorption jump factors and jump ratios in elements between Tm (Z = 69) and Os (Z = 76) derived from new mass attenuation coefficient measurements

    Kaya, Necati; Tirasoglu, Engin; Apaydin, Goekhan; Aylikci, Volkan; Cengiz, Erhan

    2007-01-01

    The K-shell absorption jump factors and jump ratios were derived from new mass attenuation coefficients measured using an energy dispersive X-ray fluorescence (EDXRF) spectrometer for Tm, Yb elements being Tm 2 O 3 , Yb 2 O 3 compounds and pure Lu, Hf, Ta, W, Re and Os. The measurements, in the region 56-77 keV, were done in a transmission geometry utilizing the K α1 , K α2 , K β1 and K β2 X- rays from different secondary source targets (Yb, Ta, Os, W, Re and Ir, etc.) excited by the 123.6 keV γ-photons from an 57 Co annular source and detected by an Ultra-LEGe solid state detector with a resolution of 150 eV at 5.9 keV. Experimental results have been compared with theoretically calculated values. The measured values of Tm, Yb, Lu, Hf, Ta, W, Re and Os are reported here for the first time

  18. Absorption coefficient instrument for turbid natural waters

    Friedman, E.; Cherdak, A.; Poole, L.; Houghton, W.

    1980-01-01

    The paper presents an instrument that directly measures multispectral absorption coefficient of turbid natural water. Attention is given to the design, which is shown to incorporate methods for the compensation of variation in the internal light source intensity, correction of the spectrally dependent nature of the optical elements, and correction for variation in the background light level. In addition, when used in conjunction with a spectrally matched total attenuation instrument, the spectrally dependent scattering coefficient can also be derived. Finally, it is reported that systematic errors associated with multiple scattering have been estimated using Monte Carlo techniques.

  19. Multiphoton absorption coefficients in solids: an universal curve

    Brandi, H.S.; Araujo, C.B. de

    1983-04-01

    An universal curve for the frequency dependence of the multiphoton absorption coefficient is proposed based on a 'non-perturbative' approach. Specific applications have been made to obtain two, three, four and five photons absorption coefficient in different materials. Properly scaling of the two photon absorption coefficient and the use of the universal curve yields results for the higher order absorption coefficients in good agreement with the experimental data. (Author) [pt

  20. Axially symmetric reconstruction of plasma emission and absorption coefficients

    Yang Lixin; Jia Hui; Yang Jiankun; Li Xiujian; Chen Shaorong; Liu Xishun

    2013-01-01

    A layered structure imaging model is developed in order to reconstruct emission coefficients and absorption coefficients simultaneously, in laser fusion core plasma diagnostics. A novel axially symmetric reconstruction method that utilizes the LM (Levenberg-Marquardt) nonlinear least squares minimization algorithm is proposed based on the layered structure. Numerical simulation results demonstrate that the proposed method is sufficiently accurate to reconstruct emission coefficients and absorption coefficients, and when the standard deviation of noise is 0.01, the errors of emission coefficients and absorption coefficients are 0.17, 0.22, respectively. Furthermore, this method could perform much better on reconstruction effect compared with traditional inverse Abel transform algorithms. (authors)

  1. A parameterization scheme for the x-ray linear attenuation coefficient and energy absorption coefficient.

    Midgley, S M

    2004-01-21

    A novel parameterization of x-ray interaction cross-sections is developed, and employed to describe the x-ray linear attenuation coefficient and mass energy absorption coefficient for both elements and mixtures. The new parameterization scheme addresses the Z-dependence of elemental cross-sections (per electron) using a simple function of atomic number, Z. This obviates the need for a complicated mathematical formalism. Energy dependent coefficients describe the Z-direction curvature of the cross-sections. The composition dependent quantities are the electron density and statistical moments describing the elemental distribution. We show that it is possible to describe elemental cross-sections for the entire periodic table and at energies above the K-edge (from 6 keV to 125 MeV), with an accuracy of better than 2% using a parameterization containing not more than five coefficients. For the biologically important elements 1 coefficients. At higher energies, the parameterization uses fewer coefficients with only two coefficients needed at megavoltage energies.

  2. Aerosol Angstrom Absorption Coefficient Comparisons during MILAGRO.

    Marley, N. A.; Marchany-Rivera, A.; Kelley, K. L.; Mangu, A.; Gaffney, J. S.

    2007-12-01

    Measurements of aerosol absorption were obtained as part of the MAX-Mex component of the MILAGRO field campaign at site T0 (Instituto Mexicano de Petroleo in Mexico City) by using a 7-channel aethalometer (Thermo- Anderson) during the month of March, 2006. The absorption measurements obtained in the field at 370, 470, 520, 590, 660, 880, and 950 nm were used to determine the aerosol Angstrom absorption exponents by linear regression. Since, unlike other absorbing aerosol species (e.g. humic like substances, nitrated PAHs), black carbon absorption is relatively constant from the ultraviolet to the infrared with an Angstrom absorption exponent of -1 (1), a comparison of the Angstrom exponents can indicate the presence of aerosol components with an enhanced UV absorption over that expected from BC content alone. The Angstrom exponents determined from the aerosol absorption measurements obtained in the field varied from - 0.7 to - 1.3 during the study and was generally lower in the afternoon than the morning hours, indicating an increase in secondary aerosol formation and photochemically generated UV absorbing species in the afternoon. Twelve-hour integrated samples of fine atmospheric aerosols (Petroleo (IMP) and CENICA.

  3. Calculation of effective absorption coefficient for aerosols of internal mixture

    Xu Bo; Huang Yinbo; Fan Chengyu; Qiao Chunhong

    2012-01-01

    The effective absorption coefficient with time of strong absorbing aerosol made of carbon dusts and water of internal mixture is analyzed, and the influence of different wavelengths and radius ratios on it is discussed. The shorter the wavelength is, the larger the effective absorption coefficient is , and more quickly it increases during 1-100 μs, and the largest increase if 132.65% during 1-100 μs. Different ratios between inner and outer radius have large influence on the effective absorption coefficient. The larger the ratio is, the larger the effective absorption coefficient is, and more quickly it increases during 1-100 μs. The increase of the effective absorption coefficient during 1-100 μs is larger than that during 100-1000 μs, and the largest increase is 138.66% during 1-100 μs. (authors)

  4. Realistic absorption coefficient of ultrathin films

    Cesaria, M; Caricato, A P; Martino, M

    2012-01-01

    Both a theoretical algorithm and an experimental procedure are discussed of a new route to determine the absorption/scattering properties of thin films deposited on transparent substrates. Notably, the non-measurable contribution of the film–substrate interface is inherently accounted for. While the experimental procedure exploits only measurable spectra combined according to a very simple algorithm, the theoretical derivation does not require numerical handling of the acquired spectra or any assumption on the film homogeneity and substrate thickness. The film absorption response is estimated by subtracting the measured absorption spectrum of the bare substrate from that of the film on the substrate structure but in a non-straightforward way. In fact, an assumption about the absorption profile of the overall structure is introduced and a corrective factor accounting for the relative film-to-substrate thickness. The method is tested on films of a well known material (ITO) as a function of the film structural quality and influence of the film–substrate interface, both deliberately changed by thickness tuning and doping. Results are found fully consistent with information obtained by standard optical analysis and band gap values reported in the literature. Additionally, comparison with a conventional method demonstrates that our route is generally more accurate even if particularly suited for very thin films. (paper)

  5. Realistic absorption coefficient of ultrathin films

    Cesaria, M.; Caricato, A. P.; Martino, M.

    2012-10-01

    Both a theoretical algorithm and an experimental procedure are discussed of a new route to determine the absorption/scattering properties of thin films deposited on transparent substrates. Notably, the non-measurable contribution of the film-substrate interface is inherently accounted for. While the experimental procedure exploits only measurable spectra combined according to a very simple algorithm, the theoretical derivation does not require numerical handling of the acquired spectra or any assumption on the film homogeneity and substrate thickness. The film absorption response is estimated by subtracting the measured absorption spectrum of the bare substrate from that of the film on the substrate structure but in a non-straightforward way. In fact, an assumption about the absorption profile of the overall structure is introduced and a corrective factor accounting for the relative film-to-substrate thickness. The method is tested on films of a well known material (ITO) as a function of the film structural quality and influence of the film-substrate interface, both deliberately changed by thickness tuning and doping. Results are found fully consistent with information obtained by standard optical analysis and band gap values reported in the literature. Additionally, comparison with a conventional method demonstrates that our route is generally more accurate even if particularly suited for very thin films.

  6. Determination of optical absorption coefficient with focusing photoacoustic imaging.

    Li, Zhifang; Li, Hui; Zeng, Zhiping; Xie, Wenming; Chen, Wei R

    2012-06-01

    Absorption coefficient of biological tissue is an important factor for photothermal therapy and photoacoustic imaging. However, its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique to quantify the target optical absorption coefficient. It utilizes the ratio of the amplitude of the peak signal from the top boundary of the target to that from the bottom boundary based on wavelet transform. This method is self-calibrating. Factors, such as absolute optical fluence, ultrasound parameters, and Grüneisen parameter, can be canceled by dividing the amplitudes of the two peaks. To demonstrate this method, we quantified the optical absorption coefficient of a target with various concentrations of an absorbing dye. This method is particularly useful to provide accurate absorption coefficient for predicting the outcomes of photothermal interaction for cancer treatment with absorption enhancement.

  7. Measurement of Absorption Coefficient of Paraformaldehyde and Metaldehyde with Terahertz Spectroscopy

    Zhang, J.; Xia, T.; Chen, Q.; Sun, Q.; Deng, Y.; Wang, C.

    2018-03-01

    The characteristic absorption spectra of paraformaldehyde and metaldehyde in the terahertz frequency region are obtained by terahertz time-domain spectroscopy (THz-TDS). In order to reduce the absorption of terahertz (THz) wave by water vapor in the air and the background noise, the measurement system was filled with dry air and the measurements were conducted at the temperature of 24°C. Meanwhile, the humidity was controlled within 10% RH. The THz frequency domain spectra of samples and their references from 0 to 2.5 THz were analyzed via Fourier transform. The refractive index and absorption coefficients of the two aldehydes were calculated by the model formulas. From 0.1 to 2.5 THz, there appear two weak absorption peaks at 1.20 and 1.66 THz in the absorption spectra of paraformaldehyde. Only one distinct absorption peak emerges at 1.83 THz for metaldehyde. There are significant differences between the terahertz absorption coefficients of paraformaldehyde and metaldehyde, which can be used as "fingerprints" to identify these substances. Furthermore, the relationship between the average absorption coefficients and mass concentrations was investigated and the average absorption coefficient-mass concentration diagrams of paraformaldehyde and metaldehyde were shown. For paraformaldehyde, there is a linear relationship between the average absorption coefficient and the natural logarithm of mass concentration. For metaldehyde, there exists a simpler linear relationship between the average absorption coefficient and the mass concentration. Because of the characteristics of THz absorption of paraformaldehyde and metaldehyde, the THz-TDS can be applied to the qualitative and quantitative detection of the two aldehydes to reduce the unpredictable hazards due to these substances.

  8. Effect of applied mechanical stress on absorption coefficient of compounds

    Gupta, Manoj Kumar, E-mail: mkgupta.sliet@gmail.com [Department of Applied Sciences, Bhai Gurdas Institute of Engineering and Technology, Sangrur (India); Singh, Gurinderjeet; Dhaliwal, A. S.; Kahlon, K. S. [Department of Physics, Sant Longowal Institute of Engineering & Technology Deemed University, Longowal (Sangrur) India-148106 (India)

    2015-08-28

    The absorption coefficient of given materials is the parameter required for the basic information. The measurement of absorption coefficient of compounds Al{sub 2}O{sub 3}, CaCO{sub 3}, ZnO{sub 2}, SmO{sub 2} and PbO has been taken at different incident photon energies 26, 59.54, 112, 1173, 1332keV. The studies involve the measurements of absorption coefficient of the self supporting samples prepared under different mechanical stress. This mechanical stress is render in terms of pressure up to 0-6 ton by using hydraulic press. Measurements shows that absorption coefficient of a material is directly proportional to applied mechanical stress on it up to some extent then become independent. Experimentally measured results are in fairly good agreement with in theoretical values obtained from WinXCOM.

  9. Use of appropriate absorption coefficients in gamma-ray dosimetry

    Gopinath, D.V.; Natarajan, A.; Subbaiah, K.V.

    1985-01-01

    The current use of the different types of absorption coefficients in the computation of γ-ray energy deposition rates and air dose is critically analyzed. Transport calculations are presented to bring out the errors associated with the use of different absorption coefficients. It is observed that except for source energies in the range of 0.3 to 3.0 MeV the consistent use of the absorption coefficient, μ/sub a/ results in an underestimate of the air dose everywhere and of energy deposition at regions away from source. The underestimate becomes more significant with increased atomic number (Z) of the medium. Based on the computations and analysis it is concluded that the absorption coefficients μ/sub a/ and μ/sub k/ are of very limited use in practical γ-ray dosimetry

  10. Absorption Coefficient in Periodic InAs/GaAs Nanostructures

    Rodriguez-BolIvar, S; Gomez-Campos, F M; Luque-Rodriguez, A; Lopez-Villanueva, J A; Carceller, J E, E-mail: fmgomez@ugr.e [Departamento de Electronica y TecnologIa de los Computadores, Facultad de Ciencias, Av. Fuentenueva s/n, C. P. 18071, Universidad de Granada (Spain)

    2010-09-01

    Periodic nanostructure manufacture has been proposed as a procedure for obtaining new materials with tunable physical properties, such as the photon absorption coefficient. In this work we have theoretically investigated this quantity in ordered InAs/GaAs cubic quantum dot systems. We solved the Schroedinger equation associated with these structures, using a set of 13x13x13 plane waves at 12,167 equally spaced points of the Q space. We focused on the transitions between minibands arising from the conduction band. We took into account the different effective masses in each material. We included the effects of the strain by taking a conduction band offset of 0.5 eV, corresponding to strained InAs in GaAs

  11. Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

    Kessler, W. J.; Carleton, K. L.; Marinelli, W. J.

    1993-01-01

    Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

  12. Measurement of gamma attenuation coefficients in UO2 and zirconium for self-absorption corrections of burn-up determination

    Podest, M.; Klima, J.; Stecher, P.; Stecherova, E.

    1978-01-01

    UO 2 pellets from ALUOX fuel elements were used in measuring the absorption coefficient of gamma radiation in UO 2 . The results of measurements of the energy dependence of the linear absorption coefficient (within 622 to 796 keV) and of the dependence on pellet density showed that in the given density interval the absorption coefficient was almost constant. The density interval was chosen to be typical for pellet fuel used in water cooled and water moderated power reactors. The results are also shown of the dependence of the mass absorption coefficient of gamma radiation in Zr on radiation energy and compared with the mass absorption coefficient of Mo; these also showed the independence of the absorption coefficient on density. The linear and mass absorption coefficients of UO 2 are considerably high and correspond approximately to the absorption coefficient of lead. For the measured energy range the variation of absorption coefficient is about 40%, which causes errors in burnup determination. The efficiency was also determined of Ge(Li) detectors for the energy range 0.5 to 1.2 MeV. The determination of the above coefficients was used for improving the gamma fuel scanning technique in determining the activity and burnup of spent fuel elements. (J.P.)

  13. X-ray absorption coefficients of the elements (Li TO Bi, U)

    Sasaki, Satoshi.

    1990-11-01

    The atomic absorption coefficient, μ a , and the mass absorption coefficient, μ/ρ, have been calculated for the elements Li to Bi and U, based on both photoelectric and scattering effects. Tables include the μ a and μ/ρ values (i) at 0.01 A intervals in the wavelength range from 0.1 to 2.89 A and (ii) at 0.0001 A intervals in the neighborhood of the K, L 1 , L 2 , and L 3 absorption edges. (author)

  14. Techniques For Measuring Absorption Coefficients In Crystalline Materials

    Klein, Philipp H.

    1981-10-01

    Absorption coefficients smaller than 0.001 cm-1 can, with more or less difficulty, be measured by several techniques. With diligence, all methods can be refined to permit measurement of absorption coefficients as small as 0.00001 cm-1. Spectral data are most readily obtained by transmission (spectrophotometric) methods, using multiple internal reflection to increase effective sample length. Emissivity measurements, requiring extreme care in the elimination of detector noise and stray light, nevertheless afford the most accessible spectral data in the 0.0001 to 0.00001 cm-1 range. Single-wavelength informa-tion is most readily obtained with modifications of laser calorimetry. Thermo-couple detection of energy absorbed from a laser beam is convenient, but involves dc amplification techniques and is susceptible to stray-light problems. Photoacoustic detection, using ac methods, tends to diminish errors of these types, but at some expense in experimental complexity. Laser calorimetry has been used for measurements of absorption coefficients as small as 0.000003 cm-1. Both transmission and calorimetric data, taken as functions of intensity, have been used for measurement of nonlinear absorption coefficients.

  15. Determination of sedimentation rates and absorption coefficient of ...

    DR. MIKE HORSFALL

    particles have pores that can absorb radiation. Gamma rays have been used to study the absorption coefficients of cobalt(II) insoluble compounds (Essien and Ekpe, 1998), densities of marine sediments. (Gerland and Villinger, 1995) and soil particle-size distribution (Vaz et al., 1992). In this study, sedimentation rates of ...

  16. Lifshitz Tails for the Interband Light Absorption Coefficient

    In this paper we consider the interband light absorption coefficient (ILAC) for various models. We show that at the lower and upper edges of the spectrum the Lifshitz tails behaviour of the density of states implies similar behaviour for the ILAC at appropriate energies. The Lifshitz tails property is also exhibited at some points ...

  17. Estimation of water absorption coefficient using the TDR method

    Suchorab, Zbigniew; Majerek, Dariusz; Brzyski, Przemysław; Sobczuk, Henryk; Raczkowski, Andrzej

    2017-07-01

    Moisture accumulation and transport in the building barriers is an important feature that influences building performance, causing serious exploitation problems as increased energy use, mold and bacteria growth, decrease of indoor air parameters that may lead to sick building syndrome (SBS). One of the parameters that is used to describe moisture characteristic of the material is water absorption coefficient being the measure of capillary behavior of the material as a function of time and the surface area of the specimen. As usual it is determined using gravimetric methods according to EN 1925:1999 standard. In this article we demonstrate the possibility of determination of water absorption coefficient of autoclaved aerated concrete (AAC) using the Time Domain Reflectometry (TDR) method. TDR is an electric technique that had been adopted from soil science and can be successfully used for real-time monitoring of moisture transport in building materials and envelopes. Data achieved using TDR readouts show high correlation with standard method of moisture absorptivity coefficient determination.

  18. Prediction of Molar Extinction Coefficients of Proteins and Peptides Using UV Absorption of the Constituent Amino Acids at 214 nm To Enable Quantitative Reverse Phase High-Performance Liquid Chromatography-Mass Spectrometry Analysis

    Kuipers, B.J.H.; Gruppen, H.

    2007-01-01

    The molar extinction coefficients of 20 amino acids and the peptide bond were measured at 214 nm in the presence of acetonitrile and formic acid to enable quantitative comparison of peptides eluting from reversed-phase high-performance liquid chromatography, once identified with mass spectrometry

  19. Energy absorption coefficients for 662 keV gamma ray in some fatty acids

    Bhandal, G.S.; Singh, K.; Rama Rani; Vijay Kumar

    1993-01-01

    The mass energy absorption coefficient refers to the amount of energy dissipation by the secondary electron set in motion as a result of interactions between incident photons and matter. Under certain conditions, the energy dissipated by electrons in a given volume can be equated to the energy absorbed in that volume. The absorbed energy is of basic interest in radiation dosimetry because it represents the amount of energy made available for the production of chemical or biological effects. Sphere transmission is employed for the direct measurement of mass energy absorption coefficients at 662 keV in some fatty acids. Excellent agreement is obtained between the measured and theoretical values. (author). 6 refs., 1 fig., 1 tab

  20. Modeling of the Interminiband Absorption Coefficient in InGaN Quantum Dot Superlattices

    Giovanni Giannoccaro

    2016-01-01

    Full Text Available In this paper, a model to estimate minibands and theinterminiband absorption coefficient for a wurtzite (WZ indium gallium nitride (InGaN self-assembled quantum dot superlattice (QDSL is developed. It considers a simplified cuboid shape for quantum dots (QDs. The semi-analytical investigation starts from evaluation through the three-dimensional (3D finite element method (FEM simulations of crystal mechanical deformation derived from heterostructure lattice mismatch under spontaneous and piezoelectric polarization effects. From these results, mean values in QDs and barrier regions of charge carriers’ electric potentials and effective masses for the conduction band (CB and three valence sub-bands for each direction are evaluated. For the minibands’ investigation, the single-particle time-independent Schrödinger equation in effective mass approximation is decoupled in three directions and resolved using the one-dimensional (1D Kronig–Penney model. The built-in electric field is also considered along the polar axis direction, obtaining Wannier–Stark ladders. Then, theinterminiband absorption coefficient in thermal equilibrium for transverse electric (TE and magnetic (TM incident light polarization is calculated using Fermi’s golden rule implementation based on a numerical integration into the first Brillouin zone. For more detailed results, an absorption coefficient component related to superlattice free excitons is also introduced. Finally, some simulation results, observations and comments are given.

  1. Measured and numerically partitioned phytoplankton spectral absorption coefficients in inland waters

    Zhang, Y.; Liu, M.; Van Dijk, M.A.; Zhu, G.; Gong, Z.; Li, Y.M.; Qin, B.

    2009-01-01

    Total particulate, tripton and phytoplankton absorption coefficients were measured for eutrophic (Lake Taihu), meso-eutrophic (Lake Tianmuhu) and mesotrophic waters (the Three Gorges Reservoir) in China using the quantitative filter technique. Meanwhile, tripton and phytoplankton absorption

  2. Light Absorption Coefficients for Soluble Species in Snow, Dome C, Antarctica, Version 1

    National Aeronautics and Space Administration — This data set contains light absorption coefficients for soluble chromophores (light-absorbing chemicals) and concentrations of hydrogen peroxide (HOOH) and nitrate...

  3. Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber

    Peng, Dong-qing; Zhu, Li-li; Li, Zhi-fang; Li, Hui

    2017-09-01

    Absorption coefficient of biological tissue is an important parameter in biomedicine, but its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique and internal light irradiation of cylindrical diffusing fiber (CDF) to quantify the target optical absorption coefficient. Absorption coefficients for ink absorbers are firstly determined through photoacoustic and spectrophotometric measurements at the same excitation, which demonstrates the feasibility of this method. Also, the optical absorption coefficients of ink absorbers with several concentrations are measured. Finally, the two-dimensional scanning photoacoustic image is obtained. Optical absorption coefficient measurement and simultaneous photoacoustic imaging of absorber non-invasively are the typical characteristics of the method. This method can play a significant role for non-invasive determination of blood oxygen saturation, the absorption-based imaging and therapy.

  4. Modelling the light absorption coefficients of oceanic waters: Implications for underwater optical applications

    Prabhakaran, Sai Shri; Sahu, Sanjay Kumar; Dev, Pravin Jeba; Shanmugam, Palanisamy

    2018-05-01

    Spectral absorption coefficients of particulate (algal and non-algal components) and dissolved substances are modelled and combined with the pure seawater component to determine the total light absorption coefficients of seawater in the Bay of Bengal. Two parameters namely chlorophyll-a (Chl) concentration and turbidity were measured using commercially available instruments with high sampling rates. For modelling the light absorption coefficients of oceanic waters, the measured data are classified into two broad groups - algal dominant and non-algal particle (NAP) dominant. With these criteria the individual absorption coefficients of phytoplankton and NAP were established based on their concentrations using an iterative method. To account for the spectral dependence of absorption by phytoplankton, the wavelength-dependent coefficients were introduced into the model. The CDOM absorption was determined by subtracting the individual absorption coefficients of phytoplankton and NAP from the measured total absorption data and then related to the Chl concentration. Validity of the model is assessed based on independent in-situ data from certain discrete locations in the Bay of Bengal. The total absorption coefficients estimated using the new model by considering the contributions of algal, non-algal and CDOM have good agreement with the measured total absorption data with the error range of 6.9 to 28.3%. Results obtained by the present model are important for predicting the propagation of the radiant energy within the ocean and interpreting remote sensing observation data.

  5. Absorptive capacity and mass customization capability

    Zhang, Min; Zhao, Xiande; Lyles, Marjorie A.; Guo, Hangfei

    2015-01-01

    Purpose The purpose of this paper is to investigate the effects of a manufacturer’s absorptive capacity (AC) on its mass customization capability (MCC). Design/methodology/approach The authors conceptualize AC within the supply chain context as four processes: knowledge acquisition from customers, knowledge acquisition from suppliers, knowledge assimilation, and knowledge application. The authors then propose and empirically test a model on the relationships among AC processes and MCC using s...

  6. Chemical effect on total mass attenuation coefficients of V, Cr, Mn, Co and Ni

    Soeguet, Oe.; Colak, S.; Bueyuekkasap, E.; Kuecuekoender, A.

    2002-01-01

    Detailed interpretation of data obtained from X-ray transmission measurements usually depends on the assumption that the contribution of each element is additive. This assumption yields the mixture rule for X-ray attenuation coefficients which is valid if molecular and chemical effects are negligible. Total mass attenuation coefficients of V, Cr, Mn, Co and Ni in various their compounds was measured. Absorption corrections were carried on data for ligands in the compounds. It was found that V, Cr, Mn, Co and Ni had different total mass attenuation coefficients in the different compounds. Results were compared with theoretical values of HUBBELL and SELTZER. (author)

  7. Temperature dependence of the absorption coefficient of water for midinfrared laser radiation

    Jansen, E. D.; van Leeuwen, T. G.; Motamedi, M.; Borst, C.; Welch, A. J.

    1994-01-01

    The dynamics of the water absorption peak around 1.94 microns was examined. This peak is important for the absorption of holmium and thulium laser radiation. To examine the effect of temperature on the absorption coefficient, the transmission of pulsed Ho:YAG, Ho:YAG, Ho:YSGG, and Tm:YAG laser

  8. Producing of Impedance Tube for Measurement of Acoustic Absorption Coefficient of Some Sound Absorber Materials

    R. Golmohammadi

    2008-04-01

    Full Text Available Introduction & Objective: Noise is one of the most important harmful agents in work environment. In spit of industrial improvements, exposure with over permissible limit of noise is counted as one of the health complication of workers. In Iran, do not exact information of the absorption coefficient of acoustic materials. Iranian manufacturer have not laboratory for measured of sound absorbance of their products, therefore using of sound absorber is limited for noise control in industrial and non industrial constructions. The goal of this study was to design an impedance tube based on pressure method for measurement of the sound absorption coefficient of acoustic materials.Materials & Methods: In this study designing of measuring system and method of calculation of sound absorption based on a available equipment and relatively easy for measurement of the sound absorption coefficient related to ISO10534-1 was performed. Measuring system consist of heavy asbestos tube, a pure tone sound generator, calibrated sound level meter for measuring of some commonly of sound absorber materials was used. Results: In this study sound absorption coefficient of 23 types of available acoustic material in Iran was tested. Reliability of results by three repeat of measurement was tested. Results showed that the standard deviation of sound absorption coefficient of study materials was smaller than .Conclusion: The present study performed a necessary technology of designing and producing of impedance tube for determining of acoustical materials absorption coefficient in Iran.

  9. Vapor-Phase Infrared Absorptivity Coefficient of Cyclohexyl Isothiocyanate

    Samuels, Alan C; Miles, Jr., Ronald W; Williams, Barry R; Hulet, Melissa S

    2008-01-01

    ...)) at a spectral resolution of 0.125 cm(-1). The chemical used in the feedstock was subjected to a rigorous analysis by gas chromatography-mass spectrometry, nuclear magnetic resonance, and Karl-Fischer titration to verify its purity...

  10. Spatial dispersion effects in spectral line broadening by pressure. I. The Bouguer Law and absorption coefficient

    Cherkasov, M.R.

    1995-01-01

    Based on the general principles of semiclassical electrodynamics, the Bouguer law is derived, and the expression for the absorption coefficient is obtained, formally including all effects related to the phenomenon of spatial dispersion

  11. Peculiarities of determination of coefficient of radionuclide absorption in alimentary canal of ruminants

    Korneev, N.A.; Sirotkin, A.N.; Rasin, I.M.; Sarapul'tsev, I.A.; Abramova, T.N.

    1986-01-01

    Sheep taken as example, the new method for calculation of the coefficient of radionuclide ( 65 Zn) absorption in gastrointestinal tract (GIT) is suggested. It is shown that the radionuclide absorption process of sheep lasted 35 h. In case of parenteral intake radionuclide excretion from tissues and organs and its inclusion in structural parts of blood occurs. In animals to which 65 Zn is injected orally, the same processes at 65 Zn simultaneous absorption in GIT during 35 h take place. In 35 hours after radio nuclide injection its absorption coefficient in the GIT of sheep constituted 10.1+-0.05%. Using traditional calculation methods the 65 Zn absorption coefficient for the first 24 h constituted 6.6%

  12. Critical mass, rod values and reactivity coefficients for Rapsodie; Masse critique, valeur des barres et coefficients de reactivite de rapsodie

    Stevens, L; Gourdon, J [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1967-07-01

    Besides a brief general description, the report contains a description and discussion of the aims, the methods used and the results of critical mass, rod worth and static reactivity coefficient measurements on the Rapsodie reactor. (authors) [French] Apres une breve description generale, le rapport decrit et discute le but, les methodes employees et les resultats des mesures de masse critique, de reactivite des barres et des coefficients de reactivite statiques du reacteur RAPSODIE. (auteurs)

  13. Overall mass-transfer coefficients in non-linear chromatography

    Mollerup, Jørgen; Hansen, Ernst

    1998-01-01

    In case of mass transfer where concentration differences in both phases must be taken into account, one may define an over-all mass-transfer coefficient basd on the apparent over-all concentration difference. If the equilibrium relationship is linear, i.e. in cases where a Henry´s law relationshi...

  14. On the sound absorption coefficient of porous asphalt pavements for oblique incident sound waves

    Bezemer-Krijnen, Marieke; Wijnant, Ysbrand H.; de Boer, Andries; Bekke, Dirk; Davy, J.; Don, Ch.; McMinn, T.; Dowsett, L.; Broner, N.; Burgess, M.

    2014-01-01

    A rolling tyre will radiate noise in all directions. However, conventional measurement techniques for the sound absorption of surfaces only give the absorption coefficient for normal incidence. In this paper, a measurement technique is described with which it is possible to perform in situ sound

  15. Vapor-Phase Infrared Absorptivity Coefficient of HN1

    2013-08-01

    the boil-off of a bulk liquid nitrogen tank, across an alumina Soxhlet thimble in a glass holder filled with the analyte. A vapor–liquid...with mass spectrometry (MS) yielded the results shown in Table 3. Table 3. Results from Analysis of HN1 Sample Used for Determination of...2 yields (3) Equation 3 can then be solved at each frequency using a least-squares approach. This was

  16. Bottom Extreme-Ultraviolet-Sensitive Coating for Evaluation of the Absorption Coefficient of Ultrathin Film

    Hijikata, Hayato; Kozawa, Takahiro; Tagawa, Seiichi; Takei, Satoshi

    2009-06-01

    A bottom extreme-ultraviolet-sensitive coating (BESC) for evaluation of the absorption coefficients of ultrathin films such as extreme ultraviolet (EUV) resists was developed. This coating consists of a polymer, crosslinker, acid generator, and acid-responsive chromic dye and is formed by a conventional spin-coating method. By heating the film after spin-coating, a crosslinking reaction is induced and the coating becomes insoluble. A typical resist solution can be spin-coated on a substrate covered with the coating film. The evaluation of the linear absorption coefficients of polymer films was demonstrated by measuring the EUV absorption of BESC substrates on which various polymers were spin-coated.

  17. Bayesian inversion from sabine absorption coefficients to flow resistivity values for porous absorbers

    Jeong, Cheol-Ho

    2015-01-01

    to determine the flow resistivity of a porous material from the Sabine absorption coefficient was investigated through a reliable model. The model for the flow resistivity estimation is based on an equivalent fluid model, i.e., Miki’s model, together with the most advanced model that accounts for edge...... diffraction, named Thomasson’s finite size correction. As input data, a set of the Sabine absorption coefficients in a recent absorption round robin test in 13 European chambers was used. Finally, the flow resistivity of the test specimen is characterized via the Bayesian framework, together...

  18. [Extracting THz absorption coefficient spectrum based on accurate determination of sample thickness].

    Li, Zhi; Zhang, Zhao-hui; Zhao, Xiao-yan; Su, Hai-xia; Yan, Fang

    2012-04-01

    Extracting absorption spectrum in THz band is one of the important aspects in THz applications. Sample's absorption coefficient has a complex nonlinear relationship with its thickness. However, as it is not convenient to measure the thickness directly, absorption spectrum is usually determined incorrectly. Based on the method proposed by Duvillaret which was used to precisely determine the thickness of LiNbO3, the approach to measuring the absorption coefficient spectra of glutamine and histidine in frequency range from 0.3 to 2.6 THz(1 THz = 10(12) Hz) was improved in this paper. In order to validate the correctness of this absorption spectrum, we designed a series of experiments to compare the linearity of absorption coefficient belonging to one kind amino acid in different concentrations. The results indicate that as agreed by Lambert-Beer's Law, absorption coefficient spectrum of amino acid from the improved algorithm performs better linearity with its concentration than that from the common algorithm, which can be the basis of quantitative analysis in further researches.

  19. The fundamental parameter approach of quantitative XRFA- investigation of photoelectric absorption coefficients

    Shaltout, A.

    2003-06-01

    The present work describes some actual problems of quantitative x-ray fluorescence analysis by means of the fundamental parameter approach. To perform this task, some of the main parameters are discussed in detail. These parameters are photoelectric cross sections, coherent and incoherent scattering cross sections, mass absorption cross sections and the variation of the x-ray tube voltage. Photoelectric cross sections, coherent and incoherent scattering cross sections and mass absorption cross sections in the energy range from 1 to 300 keV for the elements from Z=1 to 94 considering ten different data bases are studied. These are data bases given by Hubbell, McMaster, Mucall, Scofield, Xcom, Elam, Sasaki, Henke, Cullen and Chantler's data bases. These data bases have been developed also for an application in fundamental parameter programs for quantitative x-ray analysis (Energy Dispersive X-Ray Fluorescence Analysis (EDXRFA), Electron Probe Microanalysis (EPMA), X-Ray Photoelectron Spectroscopy (XPS) and Total Electron Yield (TEY)). In addition a comparison is performed between different data bases. In McMaster's data base, the missing elements (Z=84, 85, 87, 88, 89, 91, and 93) are added by using photoelectric cross sections of Scofield's data base, coherent as well as incoherent scattering cross sections of Elam's data base and the absorption edges of Bearden. Also, the N-fit coefficients of the elements from Z=61 to 69 are wrong in McMaster data base, therefore, linear least squares fits are used to recalculate the N-fit coefficients of these elements. Additionally, in the McMaster tables the positions of the M- and N-edges of all elements with the exception of the M1- and N1- edges are not defined as well as the jump ratio of the edges. In the present work, the M- and N-edges and the related jump ratios are calculated. To include the missing N-edges, Bearden's values of energy edges are used. In Scofield's data base, modifications include check and correction

  20. Measurement of atomic number and mass attenuation coefficient in ...

    literature on the measurement of mass attenuation coefficient in magnesium ferrite. The knowledge of photon ... pure) MgO and Fe2O3. The details of experimental ... and (4 4 0) planes belonging to cubic spinel structure. The XRD pattern ...

  1. Minority carrier diffusion lengths and absorption coefficients in silicon sheet material

    Dumas, K. A.; Swimm, R. T.

    1980-01-01

    Most of the methods which have been developed for the measurement of the minority carrier diffusion length of silicon wafers require that the material have either a Schottky or an ohmic contact. The surface photovoltage (SPV) technique is an exception. The SPV technique could, therefore, become a valuable diagnostic tool in connection with current efforts to develop low-cost processes for the production of solar cells. The technique depends on a knowledge of the optical absorption coefficient. The considered investigation is concerned with a reevaluation of the absorption coefficient as a function of silicon processing. A comparison of absorption coefficient values showed these values to be relatively consistent from sample to sample, and independent of the sample growth method.

  2. Dynamic absorption coefficients of chemically amplified resists and nonchemically amplified resists at extreme ultraviolet

    Fallica, Roberto; Stowers, Jason K.; Grenville, Andrew; Frommhold, Andreas; Robinson, Alex P. G.; Ekinci, Yasin

    2016-07-01

    The dynamic absorption coefficients of several chemically amplified resists (CAR) and non-CAR extreme ultraviolet (EUV) photoresists are measured experimentally using a specifically developed setup in transmission mode at the x-ray interference lithography beamline of the Swiss Light Source. The absorption coefficient α and the Dill parameters ABC were measured with unprecedented accuracy. In general, the α of resists match very closely with the theoretical value calculated from elemental densities and absorption coefficients, whereas exceptions are observed. In addition, through the direct measurements of the absorption coefficients and dose-to-clear values, we introduce a new figure of merit called chemical sensitivity to account for all the postabsorption chemical reaction ongoing in the resist, which also predicts a quantitative clearing volume and clearing radius, due to the photon absorption in the resist. These parameters may help provide deeper insight into the underlying mechanisms of the EUV concepts of clearing volume and clearing radius, which are then defined and quantitatively calculated.

  3. Semi-analytical Model for Estimating Absorption Coefficients of Optically Active Constituents in Coastal Waters

    Wang, D.; Cui, Y.

    2015-12-01

    The objectives of this paper are to validate the applicability of a multi-band quasi-analytical algorithm (QAA) in retrieval absorption coefficients of optically active constituents in turbid coastal waters, and to further improve the model using a proposed semi-analytical model (SAA). The ap(531) and ag(531) semi-analytically derived using SAA model are quite different from the retrievals procedures of QAA model that ap(531) and ag(531) are semi-analytically derived from the empirical retrievals results of a(531) and a(551). The two models are calibrated and evaluated against datasets taken from 19 independent cruises in West Florida Shelf in 1999-2003, provided by SeaBASS. The results indicate that the SAA model produces a superior performance to QAA model in absorption retrieval. Using of the SAA model in retrieving absorption coefficients of optically active constituents from West Florida Shelf decreases the random uncertainty of estimation by >23.05% from the QAA model. This study demonstrates the potential of the SAA model in absorption coefficients of optically active constituents estimating even in turbid coastal waters. Keywords: Remote sensing; Coastal Water; Absorption Coefficient; Semi-analytical Model

  4. Measurement of the sound absorption coefficient for an advanced undergraduate physics laboratory

    Macho-Stadler, E.; Elejalde-García, M. J.

    2017-09-01

    We present a simple experiment that allows advanced undergraduates to learn the basics of the acoustic properties of materials. The impedance tube-standing wave method is applied to study the normal absorption coefficient of acoustics insulators. The setup includes a tube, a speaker, a microphone, a digital function generator and an oscilloscope, material available in an undergraduate laboratory. Results of the change of the absorption coefficient with the frequency, the sample thickness and the sample density are analysed and compared with those obtained with a commercial system.

  5. Sound absorption coefficient of coal bottom ash concrete for railway application

    Ramzi Hannan, N. I. R.; Shahidan, S.; Maarof, Z.; Ali, N.; Abdullah, S. R.; Ibrahim, M. H. Wan

    2017-11-01

    A porous concrete able to reduce the sound wave that pass through it. When a sound waves strike a material, a portion of the sound energy was reflected back and another portion of the sound energy was absorbed by the material while the rest was transmitted. The larger portion of the sound wave being absorbed, the lower the noise level able to be lowered. This study is to investigate the sound absorption coefficient of coal bottom ash (CBA) concrete compared to the sound absorption coefficient of normal concrete by carried out the impedance tube test. Hence, this paper presents the result of the impedance tube test of the CBA concrete and normal concrete.

  6. Pendulum mass affects the measurement of articular friction coefficient.

    Akelman, Matthew R; Teeple, Erin; Machan, Jason T; Crisco, Joseph J; Jay, Gregory D; Fleming, Braden C

    2013-02-01

    Friction measurements of articular cartilage are important to determine the relative tribologic contributions made by synovial fluid or cartilage, and to assess the efficacy of therapies for preventing the development of post-traumatic osteoarthritis. Stanton's equation is the most frequently used formula for estimating the whole joint friction coefficient (μ) of an articular pendulum, and assumes pendulum energy loss through a mass-independent mechanism. This study examines if articular pendulum energy loss is indeed mass independent, and compares Stanton's model to an alternative model, which incorporates viscous damping, for calculating μ. Ten loads (25-100% body weight) were applied in a random order to an articular pendulum using the knees of adult male Hartley guinea pigs (n=4) as the fulcrum. Motion of the decaying pendulum was recorded and μ was estimated using two models: Stanton's equation, and an exponential decay function incorporating a viscous damping coefficient. μ estimates decreased as mass increased for both models. Exponential decay model fit error values were 82% less than the Stanton model. These results indicate that μ decreases with increasing mass, and that an exponential decay model provides a better fit for articular pendulum data at all mass values. In conclusion, inter-study comparisons of articular pendulum μ values should not be made without recognizing the loads used, as μ values are mass dependent. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Laboratory measurement of the absorption coefficient of riboflavin for ultraviolet light (365 nm).

    Iseli, Hans Peter; Popp, Max; Seiler, Theo; Spoerl, Eberhard; Mrochen, Michael

    2011-03-01

    Corneal cross-linking (CXL) is an increasingly used treatment technique for stabilizing the cornea in keratoconus. Cross-linking (polymerization) between collagen fibrils is induced by riboflavin (vitamin B2) and ultraviolet light (365 nm). Although reported to reach a constant value at higher riboflavin concentrations, the Lambert-Beer law predicts a linear increase in the absorption coefficient. This work was carried out to determine absorption behavior at different riboflavin concentrations and to further investigate the purported plateau absorption coefficient value of riboflavin and to identify possible bleaching effects. The Lambert-Beer law was used to calculate the absorption coefficient at various riboflavin concentrations. The following investigated concentrations of riboflavin solutions were prepared using a mixture of 0.5% riboflavin and 20% Dextran T500 dissolved in 0.9% sodium chloride solution: 0%, 0.02%, 0.03%, 0.04%, 0.05%, 0.06%, 0.08%, 0.1%, 0.2%, 0.3%, 0.4%, and 0.5%, and were investigated with and without aperture plate implementation. An additional test series measured the transmitted power at selected riboflavin concentrations over time. In diluted solutions, a linear correlation exists between the absorption coefficient and riboflavin concentration. The absorption coefficient reaches a plateau, but this occurs at a higher riboflavin concentration (0.1%) than previously reported (just above 0.04%). Transmitted light power increases over time, indicating a bleaching effect of riboflavin. The riboflavin concentration can be effectively varied as a treatment parameter in a considerably broader range than previously thought. Copyright 2011, SLACK Incorporated.

  8. Reconstruction of absorption and scattering coefficients in two dimensional heterogeneous participating media

    Montero, Raul F. Carita; Roberty, Nilson C.; Silva Neto, Antonio J.; Universidade Federal, Rio de Janeiro, RJ

    2002-01-01

    In the present work it is presented the solution of the two dimensional inverse radiative transfer problem of scattering and absorption coefficients estimation, in heterogeneous media, using the source-detector methodology and a discrete ordinates method consistent with the source-detector system. The mathematical formulation of the direct and inverse problems is presented as well as test case results. (author)

  9. Absorption coefficient of nearly transparent liquids measured using thermal lens spectrometry

    H.Cabrera

    2006-01-01

    Full Text Available We use an optimized pump-probe mode-mismatched thermal lens scheme to determine the optical absorption coefficient and thermal diffusivity of ethanol, benzene, acetone, methanol, toluene and chloroform. In this scheme the excitation beam is focused in the presence of a collimated probe beam. The agreement between experimentally obtained results and values reported in the literature is good.

  10. Nuclear equipment to determine soil and water mass attenuation coefficients

    Zucchi, O.L.A.D.; Nascimento Filho, V.F. do

    1984-01-01

    The feasibility of substituting the monochannel gamma spectrometer, traditionally used in the gamma ray attenuation technique, for a less sophisticated and less expensive system of integral counting is studied. The proposed system can be operated by a non-specialized person. Three detection systems were used in the determination of the mass attenuation coefficients for different types of soil and for water. (M.A.C.) [pt

  11. Quantitative photoacoustic microscopy of optical absorption coefficients from acoustic spectra in the optical diffusive regime.

    Guo, Zijian; Favazza, Christopher; Garcia-Uribe, Alejandro; Wang, Lihong V

    2012-06-01

    Photoacoustic (PA) microscopy (PAM) can image optical absorption contrast with ultrasonic spatial resolution in the optical diffusive regime. Conventionally, accurate quantification in PAM requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection bandwidth. We circumvent this requirement by quantifying the optical absorption coefficients from the acoustic spectra of PA signals acquired at multiple optical wavelengths. With the acoustic spectral method, the absorption coefficients of an oxygenated bovine blood phantom at 560, 565, 570, and 575 nm were quantified with errors of <3%. We also quantified the total hemoglobin concentration and hemoglobin oxygen saturation in a live mouse. Compared with the conventional amplitude method, the acoustic spectral method provides greater quantification accuracy in the optical diffusive regime. The limitations of the acoustic spectral method was also discussed.

  12. Absorption Mode FT-ICR Mass Spectrometry Imaging

    Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco; O' Connor, Peter B.; Heeren, Ronald M.

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  13. Statistical Models for Sediment/Detritus and Dissolved Absorption Coefficients in Coastal Waters of the Northern Gulf of Mexico

    Green, Rebecca E; Gould, Jr., Richard W; Ko, Dong S

    2008-01-01

    ... (CDOM) absorption coefficients from physical hydrographic and atmospheric properties. The models were developed for northern Gulf of Mexico shelf waters using multi-year satellite and physical data...

  14. Saponification reaction system: a detailed mass transfer coefficient determination.

    Pečar, Darja; Goršek, Andreja

    2015-01-01

    The saponification of an aromatic ester with an aqueous sodium hydroxide was studied within a heterogeneous reaction medium in order to determine the overall kinetics of the selected system. The extended thermo-kinetic model was developed compared to the previously used simple one. The reaction rate within a heterogeneous liquid-liquid system incorporates a chemical kinetics term as well as mass transfer between both phases. Chemical rate constant was obtained from experiments within a homogeneous medium, whilst the mass-transfer coefficient was determined separately. The measured thermal profiles were then the bases for determining the overall reaction-rate. This study presents the development of an extended kinetic model for considering mass transfer regarding the saponification of ethyl benzoate with sodium hydroxide within a heterogeneous reaction medium. The time-dependences are presented for the mass transfer coefficient and the interfacial areas at different heterogeneous stages and temperatures. The results indicated an important role of reliable kinetic model, as significant difference in k(L)a product was obtained with extended and simple approach.

  15. Chlorophyll specific absorption coefficient and phytoplankton biomass in the Red Sea

    Tiwari, Surya Prakash

    2015-01-01

    The role of total particulate matter, the sum of phytoplankton and nonalgal particles, is essential to understanding the distribution and pathways of particulate carbon in the ocean. Their relative contributions to light absorption and scattering are fundamental to understanding remotely sensed ocean color. Until recently, data regarding the contribution of phytoplankton and algal particles to the inherent optical properties of the Red Sea was nonexistent. Some of the first measurements of these inherent optical properties in the Red Sea including phytoplankton specific absorption coefficients (aph*(λ)) were obtained by the TARA Oceans expedition in January 2010. From these observations, chlorophyll a was calculated using the Line Height Method (LHM) that minimizes the contribution to total and particulate absorption by non-algal particles (NAP) and CDOM. Bricaud and Stramski’s (1990) a method was then used to decompose hyperspectral total particulate absorption into the contributions by phytoplankton and nonalgal particles.

  16. Analysis of the absorption coefficient by annealing in carbon implanted Nd: YVO4

    Sanchez-Morales, M E; Vazquez, G V; Lifante, G; Cantelar, E; Rickards, J; Trejo-Luna, R

    2011-01-01

    Low loss in optical waveguides is very important in order to achieve high laser efficiency. Waveguide fabrication by ion implantation generates color centers, leading to absorption losses which can be reduced by annealing; however, this process may eliminate the waveguide and hence it is necessary to consider both the optimum annealing time and temperature. This work reports the behavior of the absorption coefficient by successive annealing steps in Nd:YVO 4 implanted with a dose of 5xl0 14 ions/cm 2 .

  17. Large nonlinear absorption and refraction coefficients of carbon nanotubes estimated from femtosecond z-scan measurements

    Kamaraju, N.; Kumar, Sunil; Sood, A. K.; Guha, Shekhar; Krishnamurthy, Srinivasan; Rao, C. N. R.

    2007-12-01

    Nonlinear transmission of 80 and 140fs pulsed light with 0.79μm wavelength through single walled carbon nanotubes suspended in water containing sodium dodecyl sulfate is studied. Pulse-width independent saturation absorption and negative cubic nonlinearity are observed, respectively, in open and closed aperture z-scan experiments. The theoretical expressions derived to analyze the z-dependent transmission in the saturable limit require two photon absorption coefficient β0˜1.4cm/MW and a nonlinear index γ ˜-5.5×10-11cm2/W to fit the data.

  18. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  19. Water vapor absorption coefficients in the 8-13-micron spectral region - A critical review

    Grant, William B.

    1990-01-01

    Measurements of water vapor absorption coefficients in the thermal IR atmospheric window (8-13 microns) during the past 20 years obtained by a variety of techniques are reviewed for consistency and compared with computed values based on the AFGL spectral data tapes. The methods of data collection considered were atmospheric long path absorption with a CO2 laser or a broadband source and filters, a White cell and a CO2 laser or a broadband source and a spectrometer, and a spectrophone with a CO2 laser. Advantages and disadvantages of each measurement approach are given as a guide to further research. Continuum absorption has apparently been measured accurately to about the 5-10 percent level in five of the measurements reported.

  20. Precise determination of total absorption coefficients for low-energy gamma-quanta with Moessbauer effect

    Bonchev, T.; Statev, S.; Nejkov, Kh.

    1980-01-01

    A new method of determining the total absorption coefficient applying the Moessbauer effect is proposed. This method enables the accuracy of the measurement increase. The coefficient is measured with practically no background on using the recoilless part of gamma radiation obtained from the Moessbauer source with and without the sample between the source of the gamma-quanta and the detector. Moessbauer sources and absorbers with a single line and without an isomeric shift are used. The recoilless part of the radiation is obtained by the ''two point'' method as a difference between the numbers of photons corresponding to the stationary source and to the vibrating one with a big mean square velocity, respectively. In the concrete measurements the sources 57 Co and 119 Sn are used. The total absorption coefficient for different samples beginning with water up to plumbum is determined. The mean square error for the mean result in all measurements is less than the mean statistical error for the coefficient. The obtained experimental data give a much smaller deviation from the theoretical data of the last issue of the Stom-Israel Tables than the one expected by their authors

  1. Simultaneous effects of hydrostatic pressure and spin–orbit coupling on linear and nonlinear intraband optical absorption coefficients in a GaAs quantum ring

    Mughnetsyan, V.N.; Manaselyan, A.Kh.; Barseghyan, M.G.; Kirakosyan, A.A.

    2013-01-01

    In this paper the simultaneous effect of hydrostatic pressure and Rashba spin–orbit interaction on intraband linear and nonlinear light absorption has been investigated in cylindrical quantum ring. The one electron energy spectrum has been found using the effective mass approximation and diagonalization procedure. We have found that the Rashba interaction can lead both to the blue- or to the red-shift of the absorption spectrum depending on the transitions character, while the only red-shift is observed due to the hydrostatic pressure. - Highlights: ► The effects of hydrostatic pressure and spin–orbit coupling are investigated for quantum ring. ► The non-linear absorption coefficient is calculated. ► The hydrostatic pressure leads to the decrease in the absorption coefficient. ► Spin–orbit coupling weakens some transitions and strengthens others.

  2. Use of primary beam filtration in estimating mass attenuation coefficients by Compton scattering

    O'Connor, B.H.; Chang, W.J.

    1985-01-01

    Mass attenuation coefficients (MACs) are frequently estimated over a range of wavelengths in x-ray spectrometry from the intensity of the Compton peak I /SUB C/ associated with a prominent tube line. The MAC μ /SUB ll/ at wavelength lambda is estimated from the MAC at the Compton wavelength lambda /SUB C/ with the approximations μ /SUB ll/ α μ /SUB C/ and μ /SUB C/ α l/I /SUB C/ , Systematic errors may introduce absorption edge bias (AEB) effects into the results, caused by sample components with absorption edges between lambda /SUB C/ and lambda. A procedure is described which eliminates AEB effects by measuring I /SUB C/ using emission radiation from a primary beam filter

  3. Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption.

    Calvo-Lerma, Joaquim; Martínez-Barona, Sandra; Masip, Etna; Fornés, Victoria; Ribes-Koninckx, Carmen

    2017-10-01

    Pancreatic enzyme replacement therapy (PERT) remains a backbone in the nutritional treatment of cystic fibrosis. Currently, there is a lack of an evidence-based tool that allows dose adjustment. To date, no studies have found an association between PERT dose and fat absorption. Therefore, the aim of the study was to assess the influence of both the PERT dose and the variability in this dose on the coefficient of fat absorption (CFA). This is a retrospective longitudinal study of 16 pediatric patients (192 food records) with three consecutive visits to the hospital over a twelve-month period. Dietary fat intake and PERT were assessed via a four-day food record and fat content in stools was determined by means of a three-day stool sample collection. A beta regression model was built to explain the association between the CFA and the interaction between the PERT dose (lipase units [LU]/g dietary fat) and the variability in the PERT dose (standard deviation [SD]). The coefficient of fat absorption increased with the PERT dose when the variability in the dose was low. In contrast, even at the highest PERT dose values, the CFA decreased when the variability was high. The confidence interval suggested an association, although the analysis was not statistically significant. The variability in the PERT dose adjustment should be taken into consideration when performing studies on PERT efficiency. A clinical goal should be the maintenance of a constant PERT dose rather than trying to obtain an optimal value.

  4. Spectroscopic method for determination of the absorption coefficient in brain tissue

    Johansson, Johannes D.

    2010-09-01

    I use Monte Carlo simulations and phantom measurements to characterize a probe with adjacent optical fibres for diffuse reflectance spectroscopy during stereotactic surgery in the brain. Simulations and measurements have been fitted to a modified Beer-Lambert model for light transport in order to be able to quantify chromophore content based on clinically measured spectra in brain tissue. It was found that it is important to take the impact of the light absorption into account when calculating the apparent optical path length, lp, for the photons in order to get good estimates of the absorption coefficient, μa. The optical path length was found to be well fitted to the equation lp=a+b ln(Is)+c ln(μa)+d ln(Is)ln(μa), where Is is the reflected light intensity for scattering alone (i.e., zero absorption). Although coefficients a-d calculated in this study are specific to the probe used here, the general form of the equation should be applicable to similar probes.

  5. Functional dependence of the lower hybrid power absorption coefficient in JET

    Pericoli-Ridolfini, V.; Ekedahl, A.; Baranov, Y.

    1997-01-01

    The fraction of the coupled lower hybrid (LH) power adsorbed in divertor plasmas in JET has been determined experimentally with a method utilizing the time derivative of the total stored energy (plasma and magnetic). This method can account for the power adsorbed inside a normalized flux co-ordinate ψ ∼ 0.7. The experimental LH absorption coefficient reaches 100% at low plasma densities, antineutron e 19 m -3 and decreases to 25% at antineutron e > 3.5 x 10 19 m -3 . The LH wave accessibility to the plasma core has been found to play an important role in determining the power absorption and the radial deposition profile. The decreasing absorption is correlated with a gradual shift of the LH power deposition profile, as determined by the hard x-ray profiles, towards the plasma periphery. Similar behaviour is found in ray tracing + Fokker-Planck code calculations. The frequency spectrum of the LH pump wave as determined by a probe outside the tokamak vessel broadens strongly as the wave accessibility is reduced and the absorption drops. (author)

  6. Pressure-induced absorption coefficients for radiative transfer calculations in Titan's atmosphere

    Courtin, Regis

    1988-01-01

    The semiempirical theory of Birnbaum and Cohen (1976) is used to calculate the FIR pressure-induced absorption (PIA) spectra of N2, CH4, N2 + Ar, N2 + CH4, and N2 + H2 under conditions like those in the Titan troposphere. The results are presented graphically and compared with published data from laboratory measurements of PIA in the same gases and mixtures (Dagg et al., 1986; Dore et al., 1986). Good agreement is obtained, with only a slight underestimation of PIA at 300-400/cm in the case of CH4. The absorption coefficients are presented in tables, and it is suggested that the present findings are of value for evaluating the effects of tropospheric clouds on the Titan FIR spectrum and studying the greenhouse effect near the Titan surface.

  7. Opto-acoustic measurement of the local light absorption coefficient in turbid media: 2. On the possibility of light absorption coefficient measurement in a turbid medium from the amplitude of the opto-acoustic signal

    Pelivanov, Ivan M; Barskaya, M I; Podymova, N B; Khokhlova, Tanya D; Karabutov, Aleksander A

    2009-01-01

    The second part of this work describes the experimental technique of measuring the local light absorption in turbid media. The technique is based on the measurement of the amplitude of an opto-acoustic (OA) signal excited in a turbid medium under the condition of one-sided access to the object under study. An OA transducer is developed to perform the proposed measurement procedure. Experiments are conducted for the turbid media with different optical properties (light absorption and reduced scattering coefficients) and for different diameters of the incident laser beam. It is found that the laser beam diameter can be chosen so that the dependences of the measured OA signal amplitude on the light absorption coefficient coincide upon varying the reduced scattering coefficient by more than twice. The obtained numerical and experimental results demonstrate that the OA method is applicable for measuring the local light absorption coefficient in turbid media, for example, in biological tissues. (measurement of parametrs of laser radiation)

  8. A neural network based approach for determination of optical scattering and absorption coefficients of biological tissue

    Warncke, D; Lewis, E; Leahy, M; Lochmann, S

    2009-01-01

    The propagation of light in biological tissue depends on the absorption and reduced scattering coefficient. The aim of this project is the determination of these two optical properties using spatially resolved reflectance measurements. The sensor system consists of five laser sources at different wavelengths, an optical fibre probe and five photodiodes. For these kinds of measurements it has been shown that an often used solution of the diffusion equation can not be applied. Therefore a neural network is being developed to extract the needed optical properties out of the reflectance data. Data sets for the training, validation and testing process are provided by Monte Carlo Simulations.

  9. Mass transfer of ammonia escape and CO2 absorption in CO2 capture using ammonia solution in bubbling reactor

    Ma, Shuangchen; Chen, Gongda; Zhu, Sijie; Han, Tingting; Yu, Weijing

    2016-01-01

    Highlights: • Mass transfer coefficient models of ammonia escape were built. • Influences of temperature, inlet CO 2 and ammonia concentration were studied. • Mass transfer coefficients of ammonia escape and CO 2 absorption were obtained. • Studies can provide the basic data as a reference guideline for process application. - Abstract: The mass transfer of CO 2 capture using ammonia solution in the bubbling reactor was studied; according to double film theory, the mass transfer coefficient models and interface area model were built. Through our experiments, the overall volumetric mass transfer coefficients were obtained, while the interface areas in unit volume were estimated. The volumetric mass transfer coefficients of ammonia escaping during the experiment were 1.39 × 10 −5 –4.34 × 10 −5 mol/(m 3 s Pa), and the volumetric mass transfer coefficients of CO 2 absorption were 2.86 × 10 −5 –17.9 × 10 −5 mol/(m 3 s Pa). The estimated interface area of unit volume in the bubbling reactor ranged from 75.19 to 256.41 m 2 /m 3 , making the bubbling reactor a viable choice to obtain higher mass transfer performance than the packed tower or spraying tower.

  10. Determination of balloon gas mass and revised estimates of drag and virtual mass coefficients

    Robbins, E.; Martone, M.

    1993-01-01

    In support of the NASA Balloon Program, small-scale balloons were flown with varying lifting gas and total system mass. Instrument packages were developed to measure and record acceleration and temperature data during these tests. Top fitting and instrument payload accelerations were measured from launch to steady state ascent and through ballast drop transients. The development of the small lightweight self-powered Stowaway Special instrument packages is discussed along with mathematical models developed to determine gas mass, drag and virtual mass coefficients.

  11. ABSORPTION, SCATTERING, ATTENUATION COEFFICIENTS and Other Data from NOAA-11 SATELLITE from 19930101 to 19931231 (NCEI Accession 9300064)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Sea surface topography, absorption, scattering, attenuation coefficients and other data in this accession was collected from NOAA-11 Advanced Very High...

  12. Bayesian inference of the flow resistivity of a sound absorber and the room's influence on the Sabine absorption coefficients

    Jeong, Cheol-Ho; Choi, Sang-Hyeon; Lee, Ikjin

    2017-01-01

    A Bayesian analysis is applied to determine the flow resistivity of a porous sample and the influence of the test chamber based on measured Sabine absorption coefficient data. The Sabine absorption coefficient measured in a reverberation chamber according to ISO 354 is influenced by the test...... chamber significantly, whereas the flow resistivity is a rather reproducible material property, from which the absorptive characteristics can be calculated through reliable models. Using Sabine absorption coefficients measured in 13 European reverberation chambers, the maximum a posteriori...... and the uncertainty of the flow resistivity and the test chamber’s influence are estimated. Inclusion of more than one chamber’s absorption data helps the flow resistivity converge towards a reliable value with a standard deviation below 17%...

  13. Determination of absorption coefficient based on laser beam thermal blooming in gas-filled tube.

    Hafizi, B; Peñano, J; Fischer, R; DiComo, G; Ting, A

    2014-08-01

    Thermal blooming of a laser beam propagating in a gas-filled tube is investigated both analytically and experimentally. A self-consistent formulation taking into account heating of the gas and the resultant laser beam spreading (including diffraction) is presented. The heat equation is used to determine the temperature variation while the paraxial wave equation is solved in the eikonal approximation to determine the temporal and spatial variation of the Gaussian laser spot radius, Gouy phase (longitudinal phase delay), and wavefront curvature. The analysis is benchmarked against a thermal blooming experiment in the literature using a CO₂ laser beam propagating in a tube filled with air and propane. New experimental results are presented in which a CW fiber laser (1 μm) propagates in a tube filled with nitrogen and water vapor. By matching laboratory and theoretical results, the absorption coefficient of water vapor is found to agree with calculations using MODTRAN (the MODerate-resolution atmospheric TRANsmission molecular absorption database) and HITRAN (the HIgh-resolution atmospheric TRANsmission molecular absorption database).

  14. Carbonation Coefficients from Concrete Made with High-Absorption Limestone Aggregate

    Eric I. Moreno

    2013-01-01

    Full Text Available Normal aggregates employed in concrete have absorption levels in the range of 0.2% to 4% for coarse aggregate and 0.2 to 2% for fine aggregate. However, some aggregates have absorption levels above these values. As the porosity of concrete is related to the porosity of both the cement paste and the aggregate and the carbonation rate is a function, among other things, of the porosity of the material, there is concern about the effect of this high porosity material in achieving good quality concrete from the durability point of view. Thus, the objective of this investigation was to study the carbonation rates of concrete specimens made with high-absorption limestone aggregate. Four different water/cement ratios were used, and cylindrical concrete specimens were exposed to accelerated carbonation. High porosity values were obtained for concrete specimens beyond the expected limits for durable concrete. However, carbonation coefficients related to normal quality concrete were obtained for the lowest water/cement ratio employed suggesting that durable concrete may be obtained with this material despite the high porosity.

  15. Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption

    Joaquim Calvo-Lerma

    Full Text Available Objectives: Pancreatic enzyme replacement therapy (PERT remains a backbone in the nutritional treatment of cystic fibrosis. Currently, there is a lack of an evidence-based tool that allows dose adjustment. To date, no studies have found an association between PERT dose and fat absorption. Therefore, the aim of the study was to assess the influence of both the PERT dose and the variability in this dose on the coefficient of fat absorption (CFA. Methods: This is a retrospective longitudinal study of 16 pediatric patients (192 food records with three consecutive visits to the hospital over a twelve-month period. Dietary fat intake and PERT were assessed via a four-day food record and fat content in stools was determined by means of a three-day stool sample collection. A beta regression model was built to explain the association between the CFA and the interaction between the PERT dose (lipase units [LU]/g dietary fat and the variability in the PERT dose (standard deviation [SD]. Results: The coefficient of fat absorption increased with the PERT dose when the variability in the dose was low. In contrast, even at the highest PERT dose values, the CFA decreased when the variability was high. The confidence interval suggested an association, although the analysis was not statistically significant. Conclusion: The variability in the PERT dose adjustment should be taken into consideration when performing studies on PERT efficiency. A clinical goal should be the maintenance of a constant PERT dose rather than trying to obtain an optimal value.

  16. Density, ultrasound velocity, acoustic impedance, reflection and absorption coefficient determination of liquids via multiple reflection method.

    Hoche, S; Hussein, M A; Becker, T

    2015-03-01

    The accuracy of density, reflection coefficient, and acoustic impedance determination via multiple reflection method was validated experimentally. The ternary system water-maltose-ethanol was used to execute a systematic, temperature dependent study over a wide range of densities and viscosities aiming an application as inline sensor in beverage industries. The validation results of the presented method and setup show root mean square errors of: 1.201E-3 g cm(-3) (±0.12%) density, 0.515E-3 (0.15%) reflection coefficient and 1.851E+3 kg s(-1) m(-2) (0.12%) specific acoustic impedance. The results of the diffraction corrected absorption showed an average standard deviation of only 0.12%. It was found that the absorption change shows a good correlation to concentration variations and may be useful for laboratory analysis of sufficiently pure liquids. The main part of the observed errors can be explained by the observed noise, temperature variation and the low signal resolution of 50 MHz. In particular, the poor signal-to-noise ratio of the second reflector echo was found to be a main accuracy limitation. Concerning the investigation of liquids the unstable properties of the reference material PMMA, due to hygroscopicity, were identified to be an additional, unpredictable source of uncertainty. While dimensional changes can be considered by adequate methodology, the impact of the time and temperature dependent water absorption on relevant reference properties like the buffer's sound velocity and density could not be considered and may explain part of the observed deviations. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Evaluation of the Extinction Coefficient, Radiation Absorption and Use Efficiency of Saffron (Crocus sativus L.

    Seyyedeh Maliheh Mirhashemi

    2015-10-01

    Full Text Available Leaf area index, light extinction coefficient and radiation use efficiency are important eco-physiological characteristics for realization of crops growth, development and radiation absorption. In order to determine the leaf area index (LAI, light extinction coefficient (K and radiation use efficiency (RUE of saffron during the first and second growing seasons, four experiments were started in 2011 and ended in 2014, at the Research Farm of the Agriculture Faculty, the Ferdowsi University of Mashhad, Iran. Saffron corms with weights between 13 to15 g and density of 50 plant.m2 were cultivated in 2011 and 2012. In all experimental years during the growing season, crop sampling was taken for required measurements including the leaf area index and shoot dry weight of saffron once every 14 days. The results showed that by increasing the age of saffron from 1 year to two years, the maximum LAI of saffron increased from 0.33 to 1.81, and light extinction coefficient decreased from 1.20 to 0.54. The increasing trend of LAI was coincident with fraction of absorbed radiation for all four years of the experiment. In the first and the second growing seasons, the amount of fraction of absorbed radiation gradually increased with increasing LAI and at 1083 and 1034 GDD reached its maximum value, respectively. In saffron farms when the plant was one year old and two years old, the mean value of RUE was 0.68 and 1.73 g.MJ-1 PAR, respectively. These results indicate that by increasing the saffron age and LAI, the value of K decreases and consequently radiation absorption and use efficiency will‎ increase.

  18. Sound absorption coefficient in situ: an alternative for estimating soil loss factors.

    Freire, Rosane; Meletti de Abreu, Marco Henrique; Okada, Rafael Yuri; Soares, Paulo Fernando; GranhenTavares, Célia Regina

    2015-01-01

    The relationship between the sound absorption coefficient and factors of the Universal Soil Loss Equation (USLE) was determined in a section of the Maringá Stream basin, Paraná State, by using erosion plots. In the field, four erosion plots were built on a reduced scale, with dimensions of 2.0×12.5m. With respect to plot coverage, one was kept with bare soil and the others contained forage grass (Brachiaria), corn and wheat crops, respectively. Planting was performed without any type of conservation practice in an area with a 9% slope. A sedimentation tank was placed at the end of each plot to collect the material transported. For the acoustic system, pink noise was used in the measurement of the proposed monitoring, for collecting information on incident and reflected sound pressure levels. In general, obtained values of soil loss confirmed that 94.3% of material exported to the basin water came from the bare soil plot, 2.8% from the corn plot, 1.8% from the wheat plot, and 1.1% from the forage grass plot. With respect to the acoustic monitoring, results indicated that at 16kHz erosion plot coverage type had a significant influence on the sound absorption coefficient. High correlation coefficients were found in estimations of the A and C factors of the USLE, confirming that the acoustic technique is feasible for the determination of soil loss directly in the field. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Parameterization of the chlorophyll a-specific in vivo light absorption coefficient covering estuarine, coastal and oceanic waters

    Stæhr, P. A.; Markager, S.

    2004-01-01

    We evaluated models predicting the spectral chlorophyll-a (Chl a)-specific absorption coefficient (a*ph (¿)) from Chl a concentration [Chl a] on the basis of 465 phytoplankton absorption spectra collected in estuarine, coastal and oceanic waters. A power model on ln-transformed data provided...

  20. Detailed tabulation of atomic form factors, photoelectric absorption and scattering cross section, and mass attenuation coefficients in the vicinity of absorption edges in the soft X-ray (Z=30-36, Z=60-89, E=0.1 keV-10 keV), addressing convergence issues of earlier work

    Chantler, C.T.

    2000-01-01

    Reliable knowledge of the complex x-ray form factor [Re(f ) ] and the photoelectric attenuation coefficient (σ PE ) is required for crystallography, medical diagnosis, radiation safety, and XAFS studies. Discrepancies between currently used theoretical approaches of 200% exist for numerous elements from 1 to 3 keV x-ray energies. The key discrepancies are due to the smoothing of edge structure, the use of nonrelativistic wave functions, and the lack of appropriate convergence of wave functions. This paper addresses these key discrepancies and derives new theoretical results of substantially higher accuracy in near-edge soft x-ray regions. The high-energy limitations of the current approach are also illustrated. The energy range covered is 0.1 to 10 keV. The associated figures and tabulation demonstrate the current comparison with alternate theory and with available experimental data. In general, experimental data are not sufficiently accurate to establish the errors and inadequacies of theory at this level. However, the best experimental data and the observed experimental structure as a function of energy are strong indicators of the validity of the current approach. New developments in experimental measurement hold great promise in making critical comparisons with theory in the near future

  1. Determination of Scattering and Absorption Coefficients for Plasma-Sprayed Yttria-Stabilized Zirconia Thermal Barrier Coatings at Elevated Temperatures

    Eldridge, Jeffrey I.; Spuckler, Charles M.; Markham, James R.

    2009-01-01

    The temperature dependence of the scattering and absorption coefficients for a set of freestanding plasma-sprayed 8 wt% yttria-stabilized zirconia (8YSZ) thermal barrier coatings (TBCs) was determined at temperatures up to 1360 C in a wavelength range from 1.2 micrometers up to the 8YSZ absorption edge. The scattering and absorption coefficients were determined by fitting the directional-hemispherical reflectance and transmittance values calculated by a four-flux Kubelka Munk method to the experimentally measured hemispherical-directional reflectance and transmittance values obtained for five 8YSZ thicknesses. The scattering coefficient exhibited a continuous decrease with increasing wavelength and showed no significant temperature dependence. The scattering is primarily attributed to the relatively temperature-insensitive refractive index mismatch between the 8YSZ and its internal voids. The absorption coefficient was very low (less than 1 per centimeter) at wavelengths between 2 micrometers and the absorption edge and showed a definite temperature dependence that consisted of a shift of the absorption edge to shorter wavelengths and an increase in the weak absorption below the absorption edge with increasing temperature. The shift in the absorption edge with temperature is attributed to strongly temperature-dependent multiphonon absorption. While TBC hemispherical transmittance beyond the absorption edge can be predicted by a simple exponential decrease with thickness, below the absorption edge, typical TBC thicknesses are well below the thickness range where a simple exponential decrease in hemispherical transmittance with TBC thickness is expected. [Correction added after online publication August 11, 2009: "edge to a shorter wavelengths" has been updated as edge to shorter wavelengths."

  2. Measurement of X-ray attenuation coefficients around K-absorption edges using Fe Kα X-rays

    Kerur, B.R.; Thontadarya, S.R.; Hanumaiah, B.

    1993-01-01

    The x-ray mass attenuation coefficients were measured around the K-absorption edges of elements in the range 16 ≤ Z ≤ 30 using Fe Kα x-rays of energy 6.400 keV, which is the weighted average energy of Kα 1 and Kα 2 x-ray components from the 57 Co radioactive source. Kβ x-rays were almost eliminated by the differential absorption technique. The small difference in energy between Kα 1 and Kα 2 , 13 eV, was shown to be inconsequential by comparing the measured and theoretical values of μ/ρ for standard materials such as Al, Cu, Mo and Ta. The effect of fine structure of the K-absorption edge on μ/ρ was elucidated by using the compounds of elements in the range 16 ≤ X ≤ 30, containing one element with its K-absorption edge energy (E k ) close to the incident photon energy (E x ). The results clearly indicate the validity of the theoretical mixture rule for all those compounds whose K edge is far away from the incident energy but show deviations of as much as 10% for the manganese compound whose K edge is 140 eV above E x and about 12% for the chromium compound whose K edge is 410 eV below E x . These deviations are attributed to the possible influence of resonance Raman scattering when the incident photon energy E x is less than the edge and to the influence of EXAFS when E x is more than the edge energy. (Author)

  3. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes

    Binzoni, T; Leung, T S; Ruefenacht, D; Delpy, D T

    2006-01-01

    Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware

  4. IR Absorption Coefficients for the Quantification of Water in Hydrous Ringwoodite

    Thomas, Sylvia-Monique; Jacobsen, Steven D.; Bina, Craig R.; Smyth, Joseph R.; Frost, Daniel J.

    2010-05-01

    Raman spectroscopy, combined with the 'Comparator technique' has been developed to determine water contents ranging from a few wt ppm to wt% in glasses and nominally anhydrous minerals including garnets, olivine, and SiO2 polymorphs (Thomas et al. 2009). The routine is one promising example of quantification tools to determine mineral specific molar absorption coefficients (ɛ) for IR spectroscopy. Mineral specific absorption coefficients are required because general IR calibrations do not necessarily apply to minerals with water incorporated as hydroxyl point defects. Here we utilize the 'Comparator technique' to provide ɛ-values for a set of synthetic Fe-free (Fo100) and Fe-bearing (Fo90, Fo87, Fo83, Fo60) ringwoodites, as well as for γ-Mg2GeO4. Ringwoodite is considered one of the major phases of the Earth's lower transition zone (520-660 km depth) and the knowledge of its absolute water storage capacity is essential for modeling the Earth's deep water cycle. Samples were synthesized at variable P-T conditions in a multi-anvil press and cover a range of OH contents. Single-crystals were characterized using X-ray diffraction and IR spectroscopy. Mineral specific IR absorption coefficients were calculated from independently determined water contents from Raman spectroscopy. Unpolarized IR spectra of Mg-ringwoodite show broad absorption features in the OH region with band maxima at ~2350, 2538, 3130, 3172, 3598 and 3688 cm-1. In the spectra of Fe-bearing ringwoodite and γ-Mg2GeO4 the maxima of the main OH band are shifted to 3244 cm-1 (Fo60) and 3207 cm-1, respectively. For Mg-ringwoodite with the mean wavenumber (area-weighted average of the peak position) of 3170 cm-1 an ɛ-value of 191500 ± 38300 L cm-2/ molH2O was determined. For the ringwoodites with Fo90, Fo87 and Fo83 composition and the mean wavenumbers of 3229 cm-1, 3252 cm-1 and 3163 cm-1 values of 123600 ± 24700 L cm-2/ molH2O, 176300 ± 52900 L cm-2/ molH2O and 155000 ± 46500 L cm-2/ molH2O were

  5. The Optical Absorption Coefficient of Maize Grains Investigated by Photoacoustic Spectroscopy

    Rodríguez-Páez, C. L.; Carballo-Carballo, A.; Rico-Molina, R.; Hernández-Aguilar, C.; Domínguez-Pacheco, A.; Cruz-Orea, A.; Moreno-Martínez, E.

    2017-01-01

    In the maize and tortilla industry, it is important to characterize the color of maize ( Zea mays L.) grain, as it is one of the attributes that directly affect the quality of the tortillas consumed by the population. For this reason, the availability of alternative techniques for assessing and improving the quality of grain is valued. Photoacoustic spectroscopy has proven to be a useful tool for characterizing maize grain. So, the objective of the present study was to determine the optical absorption coefficient β of the maize grain used to make tortillas from two regions of Mexico: (a) Valles Altos, 2012-2013 production cycle and (b) Guasave, Sinaloa, 2013-2014 production cycle. Traditional reflectance measurements, physical characteristics of the grain and nutrient content were also calculated. The experimental results show different characteristics for maize grains.

  6. Coefficient of Performance Optimization of Single-Effect Lithium-Bromide Absorption Cycle Heat Pumps

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    In this paper, we investigate the coefficient of performance (COP) of a LiBr absorption cycle heat pump under different operating conditions. The investigation is carried out using a dynamical model fitted against data recorded from an actual heat pump used for district heating in S......⊘nderborg, Denmark. Since the model is too complex to study analytically, we vary different input variables within the permissible operating range of the heat pump and evaluate COP at the resulting steady-state operating points. It is found that the best set-point for each individual input is located at an extreme......-state operation of the heat pump, while avoiding crystallization issues....

  7. Evaluation of mass absorption in LiBr flat-fan sheets

    Palacios, E.; Izquierdo, M.; Marcos, J.D.; Lizarte, R.

    2009-01-01

    Experiments were conducted to determine the absorption rates of refrigerant vapour in an aqueous lithium bromide flat-fan sheet for use in absorption air-conditioning systems. The solution flow rates tested ranged from 0.023 to 0.054 kg/s (84-194 kg/h), with pressure losses in the injection nozzle of from 40 to 250 kPa. The effect of the mass flow rate on both solution residence time and the sheet deformation rate was also analyzed in absorption chambers of a pre-defined length, along with the effect of the sub-cooling temperature on the amount of vapour absorbed. The downstream evolution of approach to equilibrium factor F was quantified. The mass transfer coefficient values were found to be over 3 x 10 -4 m/s. In absorption chambers 100 mm long, over 0.8 g/s l of vapour were absorbed per chamber absorption volume. Moreover, about 600 g of vapour were absorbed per kJ of solution flow work. Flat-fan sheet configurations were found to perform better than falling film and spray absorbers.

  8. Determination of the absorption coefficient of chromophoric dissolved organic matter from underway spectrophotometry.

    Dall'Olmo, Giorgio; Brewin, Robert J W; Nencioli, Francesco; Organelli, Emanuele; Lefering, Ina; McKee, David; Röttgers, Rüdiger; Mitchell, Catherine; Boss, Emmanuel; Bricaud, Annick; Tilstone, Gavin

    2017-11-27

    Measurements of the absorption coefficient of chromophoric dissolved organic matter (ay) are needed to validate existing ocean-color algorithms. In the surface open ocean, these measurements are challenging because of low ay values. Yet, existing global datasets demonstrate that ay could contribute between 30% to 50% of the total absorption budget in the 400-450 nm spectral range, thus making accurate measurement of ay essential to constrain these uncertainties. In this study, we present a simple way of determining ay using a commercially-available in-situ spectrophotometer operated in underway mode. The obtained ay values were validated using independent collocated measurements. The method is simple to implement, can provide measurements with very high spatio-temporal resolution, and has an accuracy of about 0.0004 m -1 and a precision of about 0.0025 m -1 when compared to independent data (at 440 nm). The only limitation for using this method at sea is that it relies on the availability of relatively large volumes of ultrapure water. Despite this limitation, the method can deliver the ay data needed for validating and assessing uncertainties in ocean-colour algorithms.

  9. Realistic absorption coefficient of each individual film in a multilayer architecture

    Cesaria, M.; Caricato, A. P.; Martino, M.

    2015-02-01

    A spectrophotometric strategy, termed multilayer-method (ML-method), is presented and discussed to realistically calculate the absorption coefficient of each individual layer embedded in multilayer architectures without reverse engineering, numerical refinements and assumptions about the layer homogeneity and thickness. The strategy extends in a non-straightforward way a consolidated route, already published by the authors and here termed basic-method, able to accurately characterize an absorbing film covering transparent substrates. The ML-method inherently accounts for non-measurable contribution of the interfaces (including multiple reflections), describes the specific film structure as determined by the multilayer architecture and used deposition approach and parameters, exploits simple mathematics, and has wide range of applicability (high-to-weak absorption regions, thick-to-ultrathin films). Reliability tests are performed on films and multilayers based on a well-known material (indium tin oxide) by deliberately changing the film structural quality through doping, thickness-tuning and underlying supporting-film. Results are found consistent with information obtained by standard (optical and structural) analysis, the basic-method and band gap values reported in the literature. The discussed example-applications demonstrate the ability of the ML-method to overcome the drawbacks commonly limiting an accurate description of multilayer architectures.

  10. [Estimation of DOC concentrations using CDOM absorption coefficients: a case study in Taihu Lake].

    Jiang, Guang-Jia; Ma, Rong-Hua; Duan, Hong-Tao

    2012-07-01

    Dissolved organic carbon (DOC) is the largest organic carbon stock in water ecosystems, which plays an important role in the carbon cycle in water. Chromophoric dissolved organic matter (CDOM), an important water color variation, is the colored fraction of DOC and its absorption controls the instruction of light under water. The available linkage between DOC concentration and CDOM absorptions enables the determination of DOC accumulations using remote sensing reflectance or radiance in lake waters. The present study explored the multi-liner relationship between CDOM absorptions [a(g) (250) and a(g) (365)] and DOC concentrations in Taihu Lake, based on the available data in 4 cruises (201005, 201101, 201103, 201105) (totally 183 sampling sites). Meanwhile, the results were validated with the data of the experiment carried out from August 29 to September 2, 2011 in Taihu Lake (n = 27). Furthermore, a universal pattern of modeling from remote sensing was built for lake waters. The results demonstrated that this method provided more satisfying estimation of DOC concentrations in Taihu Lake. Except the data obtained in January 2011, the fitted results of which were not conductive to the winter dataset (201101) in Taihu Lake, due to the diverse sources and sinks of DOC and CDOM, the multi-liner relationship was robust for the data collected in the other three cruises (R2 = 0.64, RMSE = 14.31%, n = 164), which was validated using the 201108 sampling dataset (R2 = 0.67, RMSE = 10.58%, n = 27). In addition, the form of the statistic model is universal, to some extent, for other water areas, however, there is difference in the modeling coefficients. Further research should be focused on the parameterization using local data from different lakes, which provides effective methodology for the estimation of DOC concentrations in lakes and other water regions.

  11. Comparison of different models for the determination of the absorption and scattering coefficients of thermal barrier coatings

    Wang, Li; Eldridge, Jeffrey I.; Guo, S.M.

    2014-01-01

    The thermal radiative properties of thermal barrier coatings (TBCs) are becoming more important as the inlet temperatures of advanced gas-turbine engines are continuously being pushed higher in order to improve efficiency. To determine the absorption and scattering coefficients of TBCs, four-flux, two-flux and Kubelka–Munk models were introduced and used to characterize the thermal radiative properties of plasma-sprayed yttria-stabilized zirconia (YSZ) coatings. The results show that the absorption coefficient of YSZ is extremely low for wavelengths 200 μm suggests that when the coating thickness is larger than around twice the average scattering distance, the collimated flux can be simply treated as a diffuse flux inside the coating, and thus the two-flux model can be used to determine the absorption and scattering coefficients as a simplification of the four-flux model

  12. Non-invasive determination of the absorption coefficient of the brain from time-resolved reflectance using a neural network

    Jaeger, Marion; Kienle, Alwin

    2011-01-01

    We investigated the performance of a neural network for derivation of the absorption coefficient of the brain from simulated non-invasive time-resolved reflectance measurements on the head. A five-layered geometry was considered assuming that the optical properties (except the absorption coefficient of the brain) and the thickness of all layers were known with an uncertainty. A solution of the layered diffusion equation was used to train the neural network. We determined the absorption coefficient of the brain with an RMS error of <6% from reflectance data at a single distance calculated by diffusion theory. By applying the neural network to reflectance curves obtained from Monte Carlo simulations, similar errors were found. (note)

  13. Photon mass attenuation coefficients, effective atomic numbers and ...

    of atomic number Z was performed using the logarithmic regression analysis of the data measured by the authors and reported earlier. The best-fit coefficients so obtained in the photon ..... This photon build-up is a function of thickness and atomic number of the sample and also the incident photon energy, which combine to ...

  14. New naphthalene polyimide with unusual molar absorption coefficient and excited state properties: Synthesis, photophysics and electrochemistry

    Ozser, Mustafa E. [Girne American University, Faculty of Engineering and Architecture, Department of Industrial Engineering, Girne, North Cyprus (Cyprus); Yucekan, Ilke; Bodapati, Jagadeesh B. [Eastern Mediterranean University, Faculty of Arts and Sciences, Department of Chemistry, Famagusta, North Cyprus (Cyprus); Icil, Huriye, E-mail: huriye.icil@emu.edu.tr [Eastern Mediterranean University, Faculty of Arts and Sciences, Department of Chemistry, Famagusta, North Cyprus (Cyprus)

    2013-11-15

    A high molecular weight 1,4,5,8-naphthalene polyimide (ENPI) by one-step polycondensation mechanism and for comparison its monomeric diimide (ENDI) were synthesized; the photophysical and electrochemical properties were studied in detail for ENPI. Monomer has shown unusual insolubility so that the characterization proven to be difficult, whereas ENPI has shown better solubility. The molecular weight data obtained by GPC for the polymer were M{sub n}=8240 and M{sub w}=34,000 g mol{sup −1} respectively with a polydispersity of 4.13. The polyimide exhibited outstandingly high molar absorption coefficients as 599,000, 1,021,000, and 972,700 M{sup −1} cm{sup −1}, which is first time reported in literature for the characteristic 0–2, 0–1, and 0–0 electronic transitions, respectively. ENPI showed concentration dependent and red shifted excimer emission in 1,1,2,2-tetrachloroethane (TCE). The polymer has undergone multielectron reductions in CHCl{sub 3} solution below 100 mV s{sup −1} scan rates which merged into two reversible one-electron reduction peaks at higher scan rates. In solid-state, similar scan rate dependent reduction peaks were noticed. The LUMO, HOMO and optical band gap values obtained for ENPI were −3.73, −6.91, and 3.18 eV respectively. ENDI polymer with striking features has great potential as new sensitizer for efficient dye sensitized organic cells. Highlights: • A high molecular weight naphthalene polyimide was synthesized (M{sub w}=34,000 g mol{sup −1}). • The oligoether polyimide exhibited outstanding molar absorptivity (972,700 M{sup −1} cm{sup −1}). • A red shifted excimer emission has been observed. • The polymer has undergone multielectron reductions.

  15. The influence of surface modification on sound absorption coefficient of albizzia wood absorber

    Diharjo, Kuncoro; Prabowo, Anditya E.; Jamasri, Suharty, Neng Sri

    2017-01-01

    The purpose of this research is to investigate the influence of surface modification to sound absorption on absorber based albizia wood and kenaf fiber. The absorber was produced using the albizia wood as main materials, and the kenaf fiber was used as acoustic fill. The albizia wood used for producing the absorber was cut in the transverse direction so that its surface had good porosity. The size of specimens had 100 mm in diameter and 40 mm in thickness. The configuration of resonator cavities was 30 mm in diameter and 20 mm in depth, and each resonator was completed with a neck hole of the resonator. The types of surface modification were the addition of screen printing ink, fabric (with and without neck hole), and vinyl-wallpaper (with and without neck hole). According to ISO 10534-2, the absorber specimens were tested using two microphones impedance tube with random noise source to get the curve of noise absorption coefficient (NAC) for each specimen. The result shows that both unmodified absorber and absorber modified with screen printing ink have the similar characteristic of NAC and they are feasible to be used as an absorber in conversation rooms. The addition of fabric and vinyl-wallpaper as cover on the absorber surface give the positive effect of the air gap, and it increases the NAC in low frequency (100-400 Hz). However, the covers decrease the NAC in high frequency (400-1,400 Hz). The holes on the fabric and wallpaper covers give the improvement of NAC.

  16. Experimental evaluation of the objective virtual mass coefficient

    Heilbron Filho, Paulo Fernando Lavalle

    1984-04-01

    This work is a continuation of many others studies that have been made in the field of two-phase flow, concerning the influence of the void fraction in a parameter known as 'induced mass' that appears in the constitutive equation of the inter-phase force called 'virtual mass force'. The determination of the influence of the void fraction in the induced mass is done using experiment involving a bubble flow in a vertical tube filled with water. Using the two-phase flow model together with some hypothesis concerning the bubble flow experience and the constitutive equation for the virtual mass force, we achieve through the analysis of the filming of the experiment our purpose in determining the influence of the void fraction on the induced mass. (author)

  17. Correlation between oral drug absorption in humans and apparent drug permeability coefficients in human intestinal epithelial (Caco-2) cells

    Artursson, P.; Karlsson, J.

    1991-01-01

    Monolayers of a well differentiated human intestinal epithelial cell line, Caco-2, were used as a model to study passive drug absorption across the intestinal epithelium. Absorption rate constants (expressed as apparent permeability coefficients) were determined for 20 drugs and peptides with different structural properties. The permeability coefficients ranged from approximately 5 x 10 - 8 to 5 x 10 - 5 cm/s. A good correlation was obtained between data on oral absorption in humans and the results in the Caco-2 model. Drugs that are completely absorbed in humans had permeability coefficients greater than 1 x 10 - 6 cm/s. Drugs that are absorbed to greater than 1% but less than 100% had permeability coefficients of 0.1-1.0 x 10 - 6 cm/s while drugs and peptides that are absorbed to less than 1% had permeability coefficients of less than or equal to 1 x 10 - 7 cm/s. The results indicate that Caco-2 monolayers can be used as a model for studies on intestinal drug absorption

  18. Temperature modulation of the visible and near infrared absorption and scattering coefficients of human skin.

    Khalil, Omar S; Yeh, Shu-Jen; Lowery, Michael G; Wu, Xiaomao; Hanna, Charles F; Kantor, Stanislaw; Jeng, Tzyy-Wen; Kanger, Johannes S; Bolt, Rene A; de Mul, Frits F

    2003-04-01

    We determine temperature effect on the absorption and reduced scattering coefficients (mu(a) and mu(s)(')) of human forearm skin. Optical and thermal simulation data suggest that mu( a) and mu(s)(') are determined within a temperature-controlled depth of approximately 2 mm. Cutaneous mu(s)(') change linearly with temperature. Change in mu(a) was complex and irreversible above body normal temperatures. Light penetration depth (delta) in skin increased on cooling, with considerable person-to-person variations. We attribute the effect of temperature on mu(s)(') to change in refractive index mismatch, and its effect on mu(a) to perfusion changes. The reversible temperature effect on mu (s)(' ) was maintained during more than 90 min. contact between skin and the measuring probe, where temperature was modulated between 38 and 22 degrees C for multiple cycles While temperature modulated mu(s)(' ) instantaneously and reversibly, mu(a) exhibited slower response time and consistent drift. There was a statistically significant upward drift in mu(a) and a mostly downward drift in mu( s)(') over the contact period. The drift in temperature-induced fractional change in mu(s)(') was less statistically significant than the drift in mu(s)('). Deltamu( s)(') values determined under temperature modulation conditions may have less nonspecific drift than mu(s)(') which may have significance for noninvasive determination of analytes in human tissue.

  19. A new method for the direct measurement of the energy absorption coefficient of gamma rays

    Bradley, D.A.; Chong, C.S.; Shukri, A.; Tajuddin, A.A.; Ghose, A.M.

    1988-01-01

    The most important primary interaction cross section of gamma radiation which is of interest in radiation dosimetry and health physics is the energy absorption coefficient μ en of the medium under study. Direct measurement of μ en is, however, difficult and recourse is t aken to theoretical computations for its estimation. In this study a new, simple and direct method for the determination of μ en is reported. The method is based on paraxial sphere transmission using a proportional-response gamma detector. The bremsstrahlung originating from photoelectrons in the absorbing medium and fluorescence radiations from shielding etc. have been suppressed by using suitable filters. The effects of nonparaxiality of finite sample thickness have been accounted for, using extrapolation procedures. The deviation from nonproportionality and other corrections have been shown to be small. The measured value of μ en for paraffin has been determined as (3.3+-0.2)x10 -3 m 2 /Kg. This compares favourably with the theoretically computed value of 3.35 x 10 -3 m 2 /Kg given by Hubbell et al [pt

  20. Isotopic mass-dependence of noble gas diffusion coefficients inwater

    Bourg, I.C.; Sposito, G.

    2007-06-25

    Noble gas isotopes are used extensively as tracers inhydrologic and paleoclimatic studies. These applications requireknowledge of the isotopic mass (m) dependence of noble gas diffusioncoefficients in water (D), which has not been measured but is estimatedusing experimental D-values for the major isotopes along with an untestedrelationship from kinetic theory, D prop m-0.5. We applied moleculardynamics methods to determine the mass dependence of D for four noblegases at 298 K, finding that D prop m-beta with beta<0.2, whichrefutes the kinetic theory model underlying all currentapplications.

  1. ABSORBANCE, ABSORPTION COEFFICIENT, AND APPARENT QUANTUM YIELD: A COMMENT ON AMBIGUITY IN THE USE OF THESE OPTICAL CONCEPTS

    Several important optical terms such as "absorbance" and "absorption coefficient" are frequently used ambiguously in the current peer-reviewed literature. Since they are important terms that are required to derive other quantities such as the "apparent quantum yield" of photoprod...

  2. Pancreatic Enzyme Therapy and Coefficient of Fat Absorption in Children and AdolReplacement escents With Cystic Fibrosis

    Woestenenk, Janna W; van der Ent, Cornelis K.; Houwen, Roderick H J; van der Ent, CK

    Objectives: Pancreatic enzyme replacement therapy (PERT) is the proven therapy to substantially reduce fat malabsorption in patients with cystic fibrosis (CF). Few details of the daily practice regarding PERT and the resulting coefficient of fat absorption (CFA) are known. We therefore recorded the

  3. Linear and nonlinear optical absorption coefficients in GaAs/Ga1−xAlxAs concentric double quantum rings: Effects of hydrostatic pressure and aluminum concentration

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A.; Restrepo, R.L.; Duque, C.A.

    2013-01-01

    The linear and nonlinear intra-band optical absorption coefficients in GaAs/Ga 1−x Al x As two-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and aluminum concentration the energies of the ground (n=1,l=0) and the first excited state (n=2,l=1) have been found using the effective mass approximation and the transfer matrix formalism. The energies of these states and the corresponding threshold energy of the intra-band optical transitions are examined as a function of hydrostatic pressure and aluminum concentration for different sizes of the structure. We also investigated the dependencies of the linear, nonlinear, and total optical absorption coefficients as functions of the incident photon energy for different values of hydrostatic pressure, aluminum concentration, sizes of the structure, and incident optical intensity. Its is found that the effects of the hydrostatic pressure and the aluminum concentration lead to a shifting of the resonant peaks of the intra-band optical spectrum. - Highlights: ► Linear and nonlinear intra-band absorption in quantum rings. ► Threshold energy strongly depends on the hydrostatic pressure. ► Threshold energy strongly depends on the stoichiometry and sizes of structure. ► Optical absorption is affected by the incident optical intensity.

  4. Viscous slip coefficients for binary gas mixtures measured from mass flow rates through a single microtube

    Yamaguchi, H.; Takamori, K.; Perrier, P.; Graur, I.; Matsuda, Y.; Niimi, T.

    2016-01-01

    The viscous slip coefficient for helium-argon binary gas mixture is extracted from the experimental values of the mass flow rate through a microtube. The mass flow rate is measured by the constant-volume method. The viscous slip coefficient was obtained by identifying the measured mass flow rate through a microtube with the corresponding analytical expression, which is a function of the Knudsen number. The measurements were carried out in the slip flow regime where the first-order slip bounda...

  5. Vertical profiles of aerosol absorption coefficient from micro-Aethalometer data and Mie calculation over Milan.

    Ferrero, L; Mocnik, G; Ferrini, B S; Perrone, M G; Sangiorgi, G; Bolzacchini, E

    2011-06-15

    Vertical profiles of aerosol number-size distribution and black carbon (BC) concentration were measured between ground-level and 500m AGL over Milan. A tethered balloon was fitted with an instrumentation package consisting of the newly-developed micro-Aethalometer (microAeth® Model AE51, Magee Scientific, USA), an optical particle counter, and a portable meteorological station. At the same time, PM(2.5) samples were collected both at ground-level and at a high altitude sampling site, enabling particle chemical composition to be determined. Vertical profiles and PM(2.5) data were collected both within and above the mixing layer. Absorption coefficient (b(abs)) profiles were calculated from the Aethalometer data: in order to do so, an optical enhancement factor (C), accounting for multiple light-scattering within the filter of the new microAeth® Model AE51, was determined for the first time. The value of this parameter C (2.05±0.03 at λ=880nm) was calculated by comparing the Aethalometer attenuation coefficient and aerosol optical properties determined from OPC data along vertical profiles. Mie calculations were applied to the OPC number-size distribution data, and the aerosol refractive index was calculated using the effective medium approximation applied to aerosol chemical composition. The results compare well with AERONET data. The BC and b(abs) profiles showed a sharp decrease at the mixing height (MH), and fairly constant values of b(abs) and BC were found above the MH, representing 17±2% of those values measured within the mixing layer. The BC fraction of aerosol volume was found to be lower above the MH: 48±8% of the corresponding ground-level values. A statistical mean profile was calculated, both for BC and b(abs), to better describe their behaviour; the model enabled us to compute their average behaviour as a function of height, thus laying the foundations for valid parametrizations of vertical profile data which can be useful in both remote sensing

  6. Mapping Surface Water DOC in the Northern Gulf of Mexico Using CDOM Absorption Coefficients and Remote Sensing Imagery

    Kelly, B.; Chelsky, A.; Bulygina, E.; Roberts, B. J.

    2017-12-01

    Remote sensing techniques have become valuable tools to researchers, providing the capability to measure and visualize important parameters without the need for time or resource intensive sampling trips. Relationships between dissolved organic carbon (DOC), colored dissolved organic matter (CDOM) and spectral data have been used to remotely sense DOC concentrations in riverine systems, however, this approach has not been applied to the northern Gulf of Mexico (GoM) and needs to be tested to determine how accurate these relationships are in riverine-dominated shelf systems. In April, July, and October 2017 we sampled surface water from 80+ sites over an area of 100,000 km2 along the Louisiana-Texas shelf in the northern GoM. DOC concentrations were measured on filtered water samples using a Shimadzu TOC-VCSH analyzer using standard techniques. Additionally, DOC concentrations were estimated from CDOM absorption coefficients of filtered water samples on a UV-Vis spectrophotometer using a modification of the methods of Fichot and Benner (2011). These values were regressed against Landsat visible band spectral data for those same locations to establish a relationship between the spectral data, CDOM absorption coefficients. This allowed us to spatially map CDOM absorption coefficients in the Gulf of Mexico using the Landsat spectral data in GIS. We then used a multiple linear regressions model to derive DOC concentrations from the CDOM absorption coefficients and applied those to our map. This study provides an evaluation of the viability of scaling up CDOM absorption coefficient and remote-sensing derived estimates of DOC concentrations to the scale of the LA-TX shelf ecosystem.

  7. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Conti, C.C., E-mail: ccconti@ird.gov.br [Institute for Radioprotection and Dosimetry – IRD/CNEN, Rio de Janeiro (Brazil); Physics Institute, State University of Rio de Janeiro – UERJ, Rio de Janeiro (Brazil); Anjos, M.J. [Physics Institute, State University of Rio de Janeiro – UERJ, Rio de Janeiro (Brazil); Salgado, C.M. [Nuclear Engineering Institute – IEN/CNEN, Rio de Janeiro (Brazil)

    2014-09-15

    Highlights: •This work describes a procedure for sample self-absorption correction. •The use of Monte Carlo simulation to calculate the mass attenuation coefficients curve was effective. •No need for transmission measurement, saving time, financial resources and effort. •This article provides de curves for the 90° scattering angle. •Calculation on-line at (www.macx.net.br). -- Abstract: X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at (www.macx.net.br)

  8. Polaron effects on the linear and the nonlinear optical absorption coefficients and refractive index changes in cylindrical quantum dots with applied magnetic field

    Wu Qingjie; Guo Kangxian; Liu Guanghui; Wu Jinghe

    2013-01-01

    Polaron effects on the linear and the nonlinear optical absorption coefficients and refractive index changes in cylindrical quantum dots with the radial parabolic potential and the z-direction linear potential with applied magnetic field are theoretically investigated. The optical absorption coefficients and refractive index changes are presented by using the compact-density-matrix approach and iterative method. Numerical calculations are presented for GaAs/AlGaAs. It is found that taking into account the electron-LO-phonon interaction, not only are the linear, the nonlinear and the total optical absorption coefficients and refractive index changes enhanced, but also the total optical absorption coefficients are more sensitive to the incident optical intensity. It is also found that no matter whether the electron-LO-phonon interaction is considered or not, the absorption coefficients and refractive index changes above are strongly dependent on the radial frequency, the magnetic field and the linear potential coefficient.

  9. Determination of the gas-to-membrane mass transfer coefficient in a catalytic membrane reactor

    Veldsink, J.W.; Versteeg, G.F.; Swaaij, W.P.M. van

    1995-01-01

    A novel method to determine the external mass transfer coefficient in catalytic membrane reactors (Sloot et al., 1992a, b) was presented in this study. In a catalytically active membrane reactor, in which a very fast reaction occurs, the external transfer coefficient can conveniently be measured by

  10. Spatial Variation of Hydrodynamic Mass Coefficients for Tube Bundle in a Cylindrical Shell

    Yang, Keum Hee; Ryu, Ki Wahn [Chonbuk National University, Jeonju (Korea, Republic of); Park, Chi Yong [KEPCO Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    Wear of the steam generator (SG) tubes affects the performance of nuclear power plants. Generally, the problem is caused by excessive flow-induced vibration (FIV). In analyzing the FIV, many researchers have used a uniform added mass coefficient for all of the SG tubes. However, the outermost SG tubes have more structural problems than inside tubes. The purpose of this study is to find out the added mass coefficients of each tube in a cylindrical shell

  11. Calculus of the amplification and absorption coefficients of the electromagnetic waves in a cylindrical over dense plasma

    Arzate P, N.

    1994-01-01

    Based on the fundamental theory of cylindrical waveguides and resonant cavities, the main characteristic parameters of the microwave plasma source reported in [1] are calculated. The absorption coefficient of an electromagnetic wave which is excited in H 11 mode in a cylindrical waveguide that contains a cold, inhomogeneous and magnetized plasma column is determined by using the perturbative method describe in [2]. In similar way, due to the presence of the plasma column, the shifts of the resonant frequency and of the inverse of the quality of a cylindrical resonant cavity where a TE 111 mode is oscilating are obtained. Finally, based on the linear theory, an analysis of the penetration of electromagnetic fields in a semi-bounded plasma and a plasma layer is done. The reflexion, transmission and absorption coefficients of H waves for the cases of an isotropic homogeneous and weak inhomogeneous plasma are calculated. (Author)

  12. A Correction of Random Incidence Absorption Coefficients for the Angular Distribution of Acoustic Energy under Measurement Conditions

    Jeong, Cheol-Ho

    2009-01-01

    Most acoustic measurements are based on an assumption of ideal conditions. One such ideal condition is a diffuse and reverberant field. In practice, a perfectly diffuse sound field cannot be achieved in a reverberation chamber. Uneven incident energy density under measurement conditions can cause...... discrepancies between the measured value and the theoretical random incidence absorption coefficient. Therefore the angular distribution of the incident acoustic energy onto an absorber sample should be taken into account. The angular distribution of the incident energy density was simulated using the beam...... tracing method for various room shapes and source positions. The averaged angular distribution is found to be similar to a Gaussian distribution. As a result, an angle-weighted absorption coefficient was proposed by considering the angular energy distribution to improve the agreement between...

  13. Reference-free determination of tissue absorption coefficient by modulation transfer function characterization in spatial frequency domain.

    Chen, Weiting; Zhao, Huijuan; Li, Tongxin; Yan, Panpan; Zhao, Kuanxin; Qi, Caixia; Gao, Feng

    2017-08-08

    Spatial frequency domain (SFD) measurement allows rapid and non-contact wide-field imaging of the tissue optical properties, thus has become a potential tool for assessing physiological parameters and therapeutic responses during photodynamic therapy of skin diseases. The conventional SFD measurement requires a reference measurement within the same experimental scenario as that for a test one to calibrate mismatch between the real measurements and the model predictions. Due to the individual physical and geometrical differences among different tissues, organs and patients, an ideal reference measurement might be unavailable in clinical trials. To address this problem, we present a reference-free SFD determination of absorption coefficient that is based on the modulation transfer function (MTF) characterization. Instead of the absolute amplitude that is used in the conventional SFD approaches, we herein employ the MTF to characterize the propagation of the modulated lights in tissues. With such a dimensionless relative quantity, the measurements can be naturally corresponded to the model predictions without calibrating the illumination intensity. By constructing a three-dimensional database that portrays the MTF as a function of the optical properties (both the absorption coefficient μ a and the reduced scattering coefficient [Formula: see text]) and the spatial frequency, a look-up table approach or a least-square curve-fitting method is readily applied to recover the absorption coefficient from a single frequency or multiple frequencies, respectively. Simulation studies have verified the feasibility of the proposed reference-free method and evaluated its accuracy in the absorption recovery. Experimental validations have been performed on homogeneous tissue-mimicking phantoms with μ a ranging from 0.01 to 0.07 mm -1 and [Formula: see text] = 1.0 or 2.0 mm -1 . The results have shown maximum errors of 4.86 and 7% for [Formula: see text] = 1.0 mm -1 and

  14. Determination and correlation of mass transfer coefficients in a stirred cell

    Herranz, J.; Bloxom, S.R.; Keeler, J.B.; Roth, S.R.

    1975-01-01

    In the proposed Molten Salt Breeder Reactor flowsheet, a fraction of the rare earth fission products is removed from the fuel salt in mass transfer cells. To obtain design parameters for this extraction, the effect of cell size, blade diameter, phase volume, and agitation rate on the mass transfer for a high density ratio system (mercury/water) in nondispersing square cross section contactors was determined. Aqueous side mass transfer coefficients were measured by polarography over a wide range of operating conditions. Correlations for the experimental mass transfer coefficients as functions of the operating parameters are presented. Several techniques for measuring mercury-side mass transfer coefficients were evaluated and a new one is recommended

  15. Anomalous x-ray attenuation coefficients around the absorption edges using Mn Ksub(α) and Cu Ksub(α) x-rays

    Kerur, B.R.; Thontadarya, S.R.; Hanumaiah, B.

    1994-01-01

    The x-ray attenuation coefficients for three elements and for eight compounds are determined, adopting the method developed by employing a proportional counter, with a view to study the effect of fine structure on the mass attenuation coefficient values using Mn K α and Cu K α x-rays derived from K x-ray emitters, 55 Fe and 65 Zn radioactive sources, by a differential absorption technique. It is experimentally established that a small difference in energy between K α1 and K α2 (11 eV in the case of Mn K α and 24 eV in the case of the Cu K α x-ray) is inconsequential by comparing the measured and theoretical values of μ/ρ for standard elements, aluminium, copper and tantalum. The effect of fine structure on μ/ρ values is studied using the compounds containing one element with its absorption edge close to the incident photon energy. Results obtained in the present investigation show the nonvalidity of the mixture rule above the edge and also below the edge, ranging from about 600 eV below the edge to about 1500 eV about the edge. The contribution of resonance Raman scattering to the attenuation coefficient and indications to the presence of pre-edge structure similar to EXAFS are discussed. (author)

  16. Absorption coefficient measurrement of monochromatized synchrotron radiation at 0.65 - 1.3 A interval for some biological objects

    Avakian, Ts.M.; Karabekov, I.P.; Martirossian, M.A.

    1977-01-01

    The results of the measurement of absorption coefficients for some biological objects such as pea (Pissum sativum), wheat (Triticum aestivum), tobacco (Nicotiana-tabacum-α) seeds, as well as the distilled water are presented. The measurement has been carried out on the Erevan Physical Institute Electron Accelerator synchrotron radiation beam. The good agreement of experimental and calculated data for water confirms the accuracy of the results related to other objects

  17. A comparison study for mass attenuation coefficients of some amino acids using MCNP code

    Vahabi, Seyed Milad; Bahreynipour, Mostean; Shamsaie-Zafarghandi, Mojtaba [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Energy Engineering and Physics

    2017-07-15

    In this study, a novel model of MCNP4C code reported recently was used to determine the photon mass attenuation coefficients of some amino acids at energies, 123, 360, 511, 662, 1170, 1280 and 1330 keV. The simulation results were compared with the XCOM data. It was indicated that the results were highly close to the calculated XCOM values. Obtained results were used to calculate the molar extinction coefficient. All the results showed the convenience and usefulness of the model in calculation of mass attenuation coefficients of amino acids.

  18. UV absorption coefficients of Y2(1-x-y)Gd2xEu2yO3 phosphors

    Ling, M.; Yocom, P.W.; Soules, T.F.

    1990-01-01

    The ability of a phosphor to absorb 254 nm excitation is important in the development of phosphors for fluorescent lamps. Recently the optical properties of phosphor coating were modeled using ray tracing Monte-Carlo techniques. These calculations provided a relationship between absorptance measured on a semi-infinite plaque at a given wavelength and the product of the absorption coefficient of the phosphor and its particle diameter. The purpose of this work is to provide experimental data for comparison with the calculated data, to demonstrate a technique for obtaining absorption coefficients and to provide UV absorption coefficients obtained in this way for important yttrium oxide europium red-emitting phosphors

  19. Molecular design for improved photovoltaic efficiency: band gap and absorption coefficient engineering

    Mondal, Rajib; Ko, Sangwon; Norton, Joseph E.; Miyaki, Nobuyuki; Becerril, Hector A.; Verploegen, Eric; Toney, Michael F.; Bré das, Jean-Luc; McGehee, Michael D.; Bao, Zhenan

    2009-01-01

    Removing the adjacent thiophene groups around the acceptor core in low band gap polymers significantly enhances solar cell efficiency through increasing the optical absorption and raising the ionization potential of the polymer. © 2009 The Royal Society of Chemistry.

  20. Additions and corrections to the absorption coefficients of CO2 ice: Applications to the Martian south polar cap

    Calvin, W.M.

    1990-01-01

    Reflectance spectra of carbon dioxide frosts were calculated using the optical constants provided by Warren (1986) for the wavelength region 2-6 μm. In comparing these calculated spectra to spectra of frosts observed in the laboratory and on the surface of Mars, problems in the optical constants presented by Warren (1986) became apparent. Absorption coefficients for CO 2 ice have been derived using laboratory reflectance measurements and the Hapke (1981) model for calculating diffuse reflectance. This provides approximate values in regions where no data were previously available and indicates where corrections to the compilation by Warren (1986) are required. Using these coefficients to calculate the reflectance of CO 2 ice at varying grain sizes indicates that a typical Mariner polar cap spectrum is dominated by absorptions due to CO 2 frost or ice at grain sizes that are quite large, probably of the order of millimeters to centimeters. There are indications of contamination of water frost or dust, but confirmation will require more precise absorption coefficients for solid CO 2 than can be obtained from the method used here

  1. [Correlation of molecular weight and nanofiltration mass transfer coefficient of phenolic acid composition from Salvia miltiorrhiza].

    Li, Cun-Yu; Wu, Xin; Gu, Jia-Mei; Li, Hong-Yang; Peng, Guo-Ping

    2018-04-01

    Based on the molecular sieving and solution-diffusion effect in nanofiltration separation, the correlation between initial concentration and mass transfer coefficient of three typical phenolic acids from Salvia miltiorrhiza was fitted to analyze the relationship among mass transfer coefficient, molecular weight and concentration. The experiment showed a linear relationship between operation pressure and membrane flux. Meanwhile, the membrane flux was gradually decayed with the increase of solute concentration. On the basis of the molecular sieving and solution-diffusion effect, the mass transfer coefficient and initial concentration of three phenolic acids showed a power function relationship, and the regression coefficients were all greater than 0.9. The mass transfer coefficient and molecular weight of three phenolic acids were negatively correlated with each other, and the order from high to low is protocatechualdehyde >rosmarinic acid> salvianolic acid B. The separation mechanism of nanofiltration for phenolic acids was further clarified through the analysis of the correlation of molecular weight and nanofiltration mass transfer coefficient. The findings provide references for nanofiltration separation, especially for traditional Chinese medicine with phenolic acids. Copyright© by the Chinese Pharmaceutical Association.

  2. Einstein A-coefficients and statistical weights for molecular absorption transitions in the HITRAN database

    Simeckova, Marie; Jacquemart, David; Rothman, Laurence S.; Gamache, Robert R.; Goldman, Aaron

    2006-01-01

    This paper describes the calculation of the statistical weights and the Einstein A-coefficients for the 39 molecules and their associated isotopologues/isotopomers currently present in the line-by-line portion of the HITRAN database. Calculation of the Einstein A-coefficients was carried out using the HITRAN line intensities and the necessary statistical weights. The Einstein A-coefficient and the statistical weights of the upper and lower levels of the transition were added in the new format of the line parameters for the most recent edition of the HITRAN database

  3. Viscous slip coefficients for binary gas mixtures measured from mass flow rates through a single microtube

    Yamaguchi, H.; Takamori, K.; Perrier, P.; Graur, I.; Matsuda, Y.; Niimi, T.

    2016-09-01

    The viscous slip coefficient for helium-argon binary gas mixture is extracted from the experimental values of the mass flow rate through a microtube. The mass flow rate is measured by the constant-volume method. The viscous slip coefficient was obtained by identifying the measured mass flow rate through a microtube with the corresponding analytical expression, which is a function of the Knudsen number. The measurements were carried out in the slip flow regime where the first-order slip boundary condition can be applied. The measured viscous slip coefficients of binary gas mixtures exhibit a concave function of the molar ratio of the mixture, showing a similar profile with numerical results. However, from the detailed comparison between the measured and numerical values with the complete and incomplete accommodation at a surface, it is inappropriate to estimate the viscous slip coefficient for the mixture numerically by employing separately measured tangential momentum accommodation coefficient for each component. The time variation of the molar ratio in the downstream chamber was measured by sampling the gas from the chamber using the quadrupole mass spectrometer. In our measurements, it is indicated that the volume flow rate of argon is larger than that of helium because of the difference in the tangential momentum accommodation coefficient.

  4. A Method for Estimating Mass-Transfer Coefficients in a Biofilter from Membrane Inlet Mass Spectrometer Data

    Nielsen, Anders Michael; Nielsen, Lars Peter; Feilberg, Anders

    2009-01-01

    A membrane inlet mass spectrometer (MIMS) was used in combination with a developed computer model to study and improve management of a biofilter (BF) treating malodorous ventilation air from a meat rendering facility. The MIMS was used to determine percentage removal efficiencies (REs) of selected...... sulfur gases and to provide toluene retention profiles for the model to determine the air velocity and overall mass-transfer coefficient of toluene. The mass-transfer coefficient of toluene was used as a reference for determining the mass transfer of sulfur gases. By presenting the model to scenarios...... of a filter bed with a consortium of effective sulfur oxidizers, the most likely mechanism for incomplete removal of sulfur compounds from the exhaust air was elucidated. This was found to be insufficient mass transfer and not inadequate bacterial activity as anticipated by the manager of the BF. Thus...

  5. Calculation of the mass transfer coefficient for the combustion of a carbon particle

    Scala, Fabrizio [Istituto di Ricerche sulla Combustione - CNR, P.le Tecchio 80, 80125 Napoli (Italy)

    2010-01-15

    In this paper we address the calculation of the mass transfer coefficient around a burning carbon particle in an atmosphere of O{sub 2}, N{sub 2}, CO{sub 2}, CO, and H{sub 2}O. The complete set of Stefan-Maxwell equations is analytically solved under the assumption of no homogeneous reaction in the boundary layer. An expression linking the oxygen concentration and the oxygen flux at the particle surface (as a function of the bulk gas composition) is derived which can be used to calculate the mass transfer coefficient. A very simple approximate explicit expression is also given for the mass transfer coefficient, that is shown to be valid in the low oxygen flux limit or when the primary combustion product is CO{sub 2}. The results are given in terms of a correction factor to the equimolar counter-diffusion mass transfer coefficient, which is typically available in the literature for specific geometries and/or fluid-dynamic conditions. The significance of the correction factor and the accuracy of the different available expressions is illustrated for several cases of practical interest. Results show that under typical combustion conditions the use of the equimolar counter-diffusion mass transfer coefficient can lead to errors up to 10%. Larger errors are possible in oxygen-enriched conditions, while the error is generally low in oxy-combustion. (author)

  6. Precise Measurement of Refractive Index and Absorption Coefficient of Near Millimeter Wave and Far Infrared Materials.

    1987-06-01

    polyethylene. The plexiglass is a polymethyl methacrylate and the acrylic is a polymethacrylate . The polyamide(nylon) is made with adipic acid and hexamethylene...are made with acrylic acid . It was not sur- prizing to see both exhibiting similar absorption characteristics atleast 30 times higher than

  7. Radiographic and radioscopic testing of coatings with a high absorption coefficient

    Bourdarios, M.; Deleuze, M.; Lepoutre, M.

    1983-06-01

    Radiographies of a uranium disk obtained with an Ir192 source and a X-ray generator of 420kV are compared. Then a testing installation with a X-ray generator for high absorption material is studied. It comprises a mechanism to put the sample into position and a system for image processing to improve contrast and decrease background noise [fr

  8. Quantitative photoacoustic integrating sphere (QPAIS platform for absorption coefficient and Grüneisen parameter measurements: Demonstration with human blood

    Yolanda Villanueva-Palero

    2017-06-01

    Full Text Available Quantitative photoacoustic imaging in biomedicine relies on accurate measurements of relevant material properties of target absorbers. Here, we present a method for simultaneous measurements of the absorption coefficient and Grüneisen parameter of small volume of liquid scattering and absorbing media using a coupled-integrating sphere system which we refer to as quantitative photoacoustic integrating sphere (QPAIS platform. The derived equations do not require absolute magnitudes of optical energy and pressure values, only calibration of the setup using aqueous ink dilutions is necessary. As a demonstration, measurements with blood samples from various human donors are done at room and body temperatures using an incubator. Measured absorption coefficient values are consistent with known oxygen saturation dependence of blood absorption at 750 nm, whereas measured Grüneisen parameter values indicate variability among five different donors. An increasing Grüneisen parameter value with both hematocrit and temperature is observed. These observations are consistent with those reported in literature.

  9. Impact of measurement uncertainties on determination of chlorophyll-specific absorption coefficient for marine phytoplankton

    McKee, D.; Röttgers, R.; Neukermans, G.; Calzado, V.S.; Trees, C.; Ampolo-Rella, M.; Neil, C.; Cunningham, A.

    2014-01-01

    Understanding variability in the chlorophyll-specific absorption of marine phytoplankton, aph*Chl (λ), is essential for primary production modelling, calculation of underwater light field characteristics, and development of algorithms for remote sensing of chlorophyll concentrations. Previous field and laboratory studies have demonstrated significant apparent variability in aph*Chl (λ) for natural samples and algal cultures. However, the potential impact of measurement uncertain...

  10. Lithium bromide high-temperature absorption heat pump: coefficient of performance and exergetic efficiency

    Izquierdo, M [Consejo Superior de Investigaciones Cientificas, Madrid (ES). Inst. de Optica; Aroca, S [Escuela Tecnica Superior de Ingenieros Industriales, Valladolid (ES). Catedratico de Ingenieria Termica

    1990-04-01

    A theoretical study of a lithium bromide absorption heat pump, used as a machine type I and aimed to produce heat at 120{sup 0}C via waste heat sources at 60{sup 0}C, is given. Real performance conditions are stated for each component of the machine. By means of thermodynamic diagrams (p, t, x) and (h, x), the required data are obtained for calculation of the heat recovered in the evaporator Q{sub e}, the heat delivered to the absorber Q{sub a} and to the condenser Q{sub c}, and the heat supplied to the generator Q{sub g}. The heat delivered by the hot solution to the cold solution in the heat recovered Q{sub r}, and the work W{sub p} done by the solution pump are calculated. The probable COP is calculated as close to 1.4 and the working temperature in the generator ranges from 178 to 200{sup 0}C. The heat produced by the heat pump is 22% cheaper than that obtained from a cogeneration system comprising a natural gas internal combustion engine and high temperature heat pump with mechanical compression. Compared with a high temperature heat pump with mechanical compression, the heat produced by the absorption heat pump is 31% cheaper. From (h, x) and (s, x) diagrams, exergy losses for each component can be determined leading to an exergetic efficiency of 75% which provides the quality index of the absorption cycle. (author).

  11. Specific absorption and backscatter coefficient signatures in southeastern Atlantic coastal waters

    Bostater, Charles R., Jr.

    1998-12-01

    Measurements of natural water samples in the field and laboratory of hyperspectral signatures of total absorption and reflectance were obtained using long pathlength absorption systems (50 cm pathlength). Water was sampled in Indian River Lagoon, Banana River and Port Canaveral, Florida. Stations were also occupied in near coastal waters out to the edge of the Gulf Stream in the vicinity of Kennedy Space Center, Florida and estuarine waters along Port Royal Sound and along the Beaufort River tidal area in South Carolina. The measurements were utilized to calculate natural water specific absorption, total backscatter and specific backscatter optical signatures. The resulting optical cross section signatures suggest different models are needed for the different water types and that the common linear model may only appropriate for coastal and oceanic water types. Mean particle size estimates based on the optical cross section, suggest as expected, that particle size of oceanic particles are smaller than more turbid water types. The data discussed and presented are necessary for remote sensing applications of sensors as well as for development and inversion of remote sensing algorithms.

  12. Determination of self-absorption coefficient in measurement of solid sample activity using 4π ionization chamber

    Dryak, P.

    1982-01-01

    Computation based on the Monte Carlo method was tested for a 4π cylindrical ionization chamber with a detection volume of 7 litres, filled with argon. The sources are placed in the geometrical centre. The correction coefficient for self-absorption was determined as being the ratio of ionization currents induced by a source of finite size and by a massless point source. A flowchart of the program is given. The computations were experimentally tested for cylindrical sources of aqueous 137 Cs and 57 Co solutions. (M.D.)

  13. AN EFFICIENT ANALYSIS FOR ABSORPTION AND GAIN COEFFICIENTS IN 'SINGLE STEP-INDEX WAVEGUIDE'S BY USING THE ALPHA METHOD

    Mustafa TEMİZ

    2008-02-01

    Full Text Available In this study, some design parameters such as normalized frequency and especially normalized propagation constant have been obtained, depending on some parameters which are functions of energy eigenvalues of the carriers such as electrons and holes confined in a single step-index waveguide laser (SSIWGL or single stepindex waveguide (SSIWG. Some optical expressions about the optical power and probability quantities for the active region and cladding layers of the SSIWG or SSIWGL have been investigated. Investigations have been undertaken in terms of these parameters and also individually the optical even and odd electric field waves with the lowest-modes were theoretically computed. Especially absorption coefficients and loss coefficients addition to some important quantities of the single step-index waveguide lasers for the even and odd electric field waves are evaluated.

  14. Polarization dependence of two-photon absorption coefficient and nonlinear susceptibility tensor in InP

    Matsusue, Toshio; Bando, Hiroyuki; Fujita, Shoichi; Takayama, Yusuke

    2011-01-01

    Two-photon absorption (TPA) effect in (001) InP is investigated using fs laser. Its dependences on wavelength and polarization are clarified by single and double beam methods with linearly polarized lights. Characteristic features are revealed and discussed with scaling law, crystal bonding and mutual relation of polarizations for double beams. The results are successfully analyzed on the basis of the third-order susceptibility tensor for comprehensive understanding of TPA effect at any polarization geometry. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. ABSORPTION, SCATTERING, ATTENUATION COEFFICIENTS and Other Data from NOAA-11 SATELLITE From East Coast - US/Canada and Others from 19920201 to 19920331 (NCEI Accession 9200072)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Sea surface topography, absorption, scattering, attenuation coefficients and other data in this accession was collected from NOAA-11 satellite in East Coast...

  16. ABSORPTION, SCATTERING, ATTENUATION COEFFICIENTS and Other Data from NOAA-11 SATELLITE and Other Platforms from 19950101 to 19951231 (NCEI Accession 9500020)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Sea surface topography, absorption, scattering, attenuation coefficients and other data in this accession was collected from NOAA-11 AVHRR satellite in East...

  17. Development of a model to determine mass transfer coefficient and oxygen solubility in bioreactors

    Johnny Lee

    2017-02-01

    where T is in degree Kelvin, and the subscripts refer to degree Celsius; E, ρ, σ are properties of water. Furthermore, using data from published data on oxygen solubility in water, it was found that solubility bears a linear and inverse relationship with the mass transfer coefficient.

  18. Transmission coefficient and heat conduction of a harmonic chain with random masses

    Verheggen, T.

    1979-01-01

    We find upper and lower bounds for the transmission coefficient of a chain of random masses. Using these bounds we show that the heat conduction in such a chain does not obey Fourier's law: For different temperatures at the ends of a chain containing N particles the energy flux falls off like Nsup(-1/2) rather than N -1 . (orig.)

  19. Predicting dissolved lignin phenol concentrations in the coastal ocean from chromophoric dissolved organic matter (CDOM absorption coefficients

    Cédric G. Fichot

    2016-02-01

    Full Text Available Dissolved lignin is a well-established biomarker of terrigenous dissolved organic matter (DOM in the ocean, and a chromophoric component of DOM. Although evidence suggests there is a strong linkage between lignin concentrations and chromophoric DOM (CDOM absorption coefficients in coastal waters, the characteristics of this linkage and the existence of a relationship that is applicable across coastal oceans remain unclear. Here, 421 paired measurements of dissolved lignin concentrations (sum of 9 lignin phenols and CDOM absorption coefficients (ag(λ were used to examine their relationship along the river-ocean continuum (0-37 salinity and across contrasting coastal oceans (sub-tropical, temperate, high-latitude. Overall, lignin concentrations spanned four orders of magnitude and revealed a strong, non-linear relationship with ag(λ. The characteristics of the relationship (shape, wavelength dependency, lignin-composition dependency and evidence from degradation indicators were all consistent with lignin being an important driver of CDOM variability in coastal oceans, and suggested physical mixing and long-term photodegradation were important in shaping the relationship. These observations were used to develop two simple empirical models for estimating lignin concentrations from ag(λ with a +/- 20% error relative to measured values. The models are expected to be applicable in most coastal oceans influenced by terrigenous inputs.

  20. Measurement of mass attenuation coefficients of moderate-to-high atomic-number elements at low photon energies

    Tajuddin, A.A.; Chong, C.S.; Shukri, A.; Bradley, D.A.

    1995-01-01

    Mass attenuation coefficients for 12 selected moderate-to-high atomic-number elements have been obtained from good-geometry measurements made at five 241 Am photon energies of significant emission intensity. Particular interest focuses on measured values for photon energies close to absorption edges. Comparisons with renormalized cross-section predictions indicate agreement to within stated error limits for the majority of cases. Significant discrepancies (> 10%) are noted for Ta at 17.8 and 26.3 keV and W at 59.5 keV. Some support for a discrepancy between measurement and theory for W in the region of 60 keV is found in the reported measurements of others. (author)

  1. Changing of optical absorption and scattering coefficients in nonlinear-optical crystal lithium triborate before and after interaction with UV-radiation

    Demkin, Artem S.; Nikitin, Dmitriy G.; Ryabushkin, Oleg A.

    2016-04-01

    In current work optical properties of LiB3O5 (LBO) crystal with ultraviolet (UV) (λ= 266 nm) induced volume macroscopic defect (track) are investigated using novel piezoelectric resonance laser calorimetry technique. Pulsed laser radiation of 10 W average power at 532 nm wavelength, is consecutively focused into spatial regions with and without optical defect. For these cases exponential fitting of crystal temperature kinetics measured during its irradiation gives different optical absorption coefficients α1 = 8.1 • 10-4 cm-1 (region with defect) and α =3.9ṡ10-4 cm-1 (non-defected region). Optical scattering coefficient is determined as the difference between optical absorption coefficients measured for opaque and transparent lateral facets of the crystal respectively. Measurements reveal that scattering coefficient of LBO in the region with defect is three times higher than the optical absorption coefficient.

  2. Determination of scattering coefficient considering wavelength and absorption dependence of anisotropy factor measured by polarized beam for biological tissues

    Fukutomi, D.; Ishii, K.; Awazu, K.

    2015-12-01

    Anisotropy factor g, one of the optical properties of biological tissues, is the most important parameter to accurately determine scattering coefficient μs in the inverse Monte Carlo (iMC) simulation. It has been reported that g has wavelength and absorption dependence, however, there are few attempts in order to calculate μs of biological tissue considering the wavelength and absorption dependence of g. In this study, the scattering angular distributions of biological tissue phantoms were measured in order to determine g by using goniometric measurements with three polarization conditions at strongly and weakly absorbing wavelengths of hemoglobin. Then, optical properties, especially, μs were measured by integrating sphere measurements and iMC simulation in order to confirm the influence of measured g on optical properties in comparison of with general value of g (0.9) for soft biological tissue. Consequently, it was found that μs was overestimated at strongly absorbing wavelength, however, μs was underestimated at weakly absorbing wavelength if the g was not considered its wavelength and absorption dependence.

  3. Gastrointestinal absorption of neptunium in primates: effect of ingested mass, diet, and fasting

    Metivier, H.; Bourges, J.; Fritsch, P.; Nolibe, D.; Masse, R.

    1986-01-01

    Absorption and retention of neptunium were determined in baboons after intragastric administration of neptunium nitrate solutions at pH 1. The effects of mass, diet, and fasting on absorption were studied. At higher mass levels (400-800 micrograms Np/kg), absorption was about 1%; at lower mass intakes (0.0009-0.005 micrograms Np/kg), absorption was reduced by 10- to 20-fold. The addition of an oxidizing agent (Fe3+) increased gastrointestinal absorption and supported the hypothesis of a reduction of Np (V) when loss masses were ingested. Diets depleted of or enriched with hydroxy acids did not modify retention of neptunium but increased urinary excretion with increasing hydroxy acid content. The diet enriched with milk components reduced absorption by a factor of 5. Potatoes increased absorption and retention by a factor 5, not necessarily due to the effect of phytate. Fasting for 12 or 24 h increased retention and absorption by factors of about 3 and 10, respectively. Data obtained in baboons when low masses of neptunium were administered suggest that the f1 factor used by ICRP should be decreased. However, fasting as encountered in certain nutritional habits is a factor to be taken into consideration

  4. Experimental and Numerical Study on Effects of Airflow and Aqueous Ammonium Temperature on Ammonia Mass Transfer Coefficient

    Rong, Li; Nielsen, Peter V.; Zhang, Guoqiang

    2010-01-01

    greatly along the airflow direction on the emission surface. The average mass transfer coefficient increases with higher velocity and turbulence intensity. However, the mass transfer coefficient estimated by CFD simulation is consistently larger than the calculated one by the method using dissociation...... constant and Henry's constant models. In addition, the results show that the liquid-air temperature difference has little impact on the simulated mass transfer coefficient by CFD modeling, whereas the mass transfer coefficient increases with higher liquid temperature using the other method under...... the conditions that the liquid temperature is lower than the air temperature. Although there are differences of mass transfer coefficients between these two methods, the mass transfer coefficients determined by these two methods are significantly related....

  5. Single-experiment simultaneous-measurement of elemental mass-attenuation coefficients of hydrogen, carbon and oxygen for 0.123-1.33 MeV gamma rays

    Teli, M.T.; Nathuram, R.; Mahajan, C.S.

    2000-01-01

    As it is inconvenient to use elements like hydrogen, carbon and oxygen in pure forms for measurement of their gamma mass-attenuation coefficients, the measurements are to be done indirectly, by using compounds of the elements or a mixture of them. We give here a simple method of measuring the total mass-attenuation coefficients μ/ρ of the elements in a compound simultaneously and in a single experiment through the measurements of the μ/ρ values of the concerned compounds and using the mixture rule. The method is applied for the measurement of μ/ρ of hydrogen, carbon and oxygen by using acetone, ethanol and 1-propanol. Our results (for E γ =0.123-1.33 MeV) are seen to be in better agreement with the theoretical values of Hubbell and Seltzer (1995) [Hubbell J.H. and Seltzer S.M. (1995). Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest. NISTIR 5632] as compared to the results of El-Kateb and Abdul-Hamid (1991) [El-Kateb, A.H., Abdul-Hamid, A.S., 1991. Photon attenuation coefficient study of some materials containing hydrogen, carbon, and oxygen. Appl. Rad. Isot. 42, 303-307

  6. Characterization of the Metrology beamline at the SOLEIL synchrotron and application to the determination of mass attenuation coefficients of Ag and Sn in the range 3.5 ≤ E ≤ 28 keV

    Menesguen, Y.; Lepy, M.C.

    2011-01-01

    This work presents the new Metrology beamline at the SOLEIL synchrotron facility and a first attempt to quantitative measurements of mass attenuation coefficients for Ag and Sn performed on the hard X-ray branch. We first describe the beamline itself and the characterization performed of the unfocused monochromatic beam running mode. We performed a first experimental measurement of mass attenuation coefficients in the range 3.5 ≤ E ≤ 28 keV and we also derived the K-absorption and L-absorption jump ratios. The results are compared with theoretical values as well as with other experimental data and agree well with previous published values. (authors)

  7. Compositional dependence of absorption coefficient and band-gap for Nb2O5-SiO2 mixture thin films

    Sancho-Parramon, Jordi; Janicki, Vesna; Zorc, Hrvoje

    2008-01-01

    The absorption coefficient of composite films consisting of niobia (Nb 2 O 5 ) and silica (SiO 2 ) mixtures is studied for photon energies around the band gap. The films were deposited by co-evaporation and their composition was varied by changing the ratio of deposition rates of the two materials. Both, as-deposited and thermally annealed films were characterized by different techniques: the absorption coefficient was determined by spectrophotometric measurements and the structural properties were investigated using infrared spectroscopy, transmission electron microscopy and X-ray diffraction. The correlation between the variations of absorption properties and film composition and structure is established. The absorption coefficients determined experimentally are compared with the results derived from effective medium theories in order to evaluate the suitability of these theories for the studied composites

  8. Effect of the concentration of magnetic grains on the linear-optical-absorption coefficient of ferrofluid-doped lyotropic mesophases: deviation from the Beer-Lambert law.

    Cuppo, F L S; Gómez, S L; Figueiredo Neto, A M

    2004-04-01

    In this paper is reported a systematic experimental study of the linear-optical-absorption coefficient of ferrofluid-doped isotropic lyotropic mixtures as a function of the magnetic-grains concentration. The linear optical absorption of ferrolyomesophases increases in a nonlinear manner with the concentration of magnetic grains, deviating from the usual Beer-Lambert law. This behavior is associated to the presence of correlated micelles in the mixture which favors the formation of small-scale aggregates of magnetic grains (dimers), which have a higher absorption coefficient with respect to that of isolated grains. We propose that the indirect heating of the micelles via the ferrofluid grains (hyperthermia) could account for this nonlinear increase of the linear-optical-absorption coefficient as a function of the grains concentration.

  9. Measurement of the electronic absorption coefficient for 57Co 14.4 keV gamma photons in aluminium using the Moessbauer effect as a monochromator

    Rajan, N.; Nigam, A.K.

    1984-01-01

    The total electronic absorption coefficient for 14.4 keV gamma photons in aluminium, has been measured experimentally, for the first time, using the Moessbauer effect as a monochromator. This data is important for the determination of background in Moessbauer recoilless fraction measurements especially if the energy of X-rays of the source host lattice lie near the 14.4 keV photon energy (e.g. in Rh and Pd) in which case electronic absorption coefficients should be known precisely. The coefficient obtained by interpolation from available values at other energies differ from our experimental value by as much as 20%. It is shown that this can lead to errors, in recoilless fraction values, which are far from negligible. The above absorption coefficient for aluminium was measured to be 11+-1 cm 2 /g. (orig.)

  10. Antimony orthophosphate glasses with large nonlinear refractive indices, low two-photon absorption coefficients, and ultrafast response

    Falcao-Filho, E.L.; Araujo, Cid B. de; Bosco, C.A.C.; Maciel, G.S.; Acioli, L.H.; Nalin, M.; Messaddeq, Y.

    2005-01-01

    Antimony glasses based on the composition Sb 2 O 3 -SbPO 4 were prepared and characterized. The samples present high refractive index, good transmission from 380 to 2000 nm, and high thermal stability. The nonlinear refractive index, n 2 , of the samples was studied using the optical Kerr shutter technique at 800 nm. The third-order correlation signals between pump and probe pulses indicate ultrafast response ( 2 was observed by adding lead oxide to the Sb 2 O 3 -SbPO 4 composition. Large values of n 2 ≅10 -14 cm 2 /W and negligible two-photon absorption coefficients (smaller than 0.01 cm/GW) were determined for all samples. The glass compositions studied present appropriate figure-of-merit for all-optical switching applications

  11. Guideline for Adopting the Local Reaction Assumption for Porous Absorbers in Terms of Random Incidence Absorption Coefficients

    Jeong, Cheol-Ho

    2011-01-01

    resistivity and the absorber thickness on the difference between the two surface reaction models are examined and discussed. For a porous absorber backed by a rigid surface, the assumption of local reaction always underestimates the random incidence absorption coefficient and the local reaction models give...... incidence acoustical characteristics of typical building elements made of porous materials assuming extended and local reaction. For each surface reaction, five well-established wave propagation models, the Delany-Bazley, Miki, Beranek, Allard-Champoux, and Biot model, are employed. Effects of the flow...... errors of less than 10% if the thickness exceeds 120 mm for a flow resistivity of 5000 Nm-4s. As the flow resistivity doubles, a decrease in the required thickness by 25 mm is observed to achieve the same amount of error. For an absorber backed by an air gap, the thickness ratio between the material...

  12. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik [Sogang University, Seoul (Korea, Republic of); Yasin, Muhammad; Park, Shinyoung; Chang, In Seop [Gwangju Institute of Science and Technology (GIST), Gwangju (Korea, Republic of); Lee, Eun Yeol [Kyung Hee University, Yongin (Korea, Republic of)

    2015-06-15

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k{sub L}a). The feasibility of the new reactor was demonstrated by measuring k{sub L}a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k{sub L}a value of 102.9 h{sup -1} was obtained.

  13. Mass attenuation coefficients of X-rays in different medicinal plants

    Morabad, R B [Department of Post-Graduate Studies and Research in Physics, Gulbarga University, Gulbarga 585106, Karnataka (India); Kerur, B.R. [Department of Post-Graduate Studies and Research in Physics, Gulbarga University, Gulbarga 585106, Karnataka (India)], E-mail: kerurbrk@yahoo.com

    2010-02-15

    The mass attenuation coefficients of specific parts of several plants, (fruits, leaves, stem and seeds) often used as medicines in the Indian herbal system, have been measured employing NaI (TI)) detector. The electronic setup used is a NaI (TI) detector, which is coupled to MCA for analysis of the spectrum. A source of {sup 241}Am is used to get X-rays in the energy range 8-32 keV from Cu, Rb, Mo, Ag and Ba targets. In the present study, the measured mass attenuation coefficient of Ocimum sanctum, Catharanthus roseus, Trigonella foenum-graecum, Azadirachta indica, Aegle marmelos, Zingiber officinalis, Emblica officinalis, Anacardium occidentale, Momordica charantia and Syzygium cumini show a linear relation with the energy.

  14. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik; Yasin, Muhammad; Park, Shinyoung; Chang, In Seop; Lee, Eun Yeol

    2015-01-01

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k L a). The feasibility of the new reactor was demonstrated by measuring k L a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k L a value of 102.9 h -1 was obtained

  15. Mass attenuation coefficients of X-rays in different medicinal plants

    Morabad, R.B.; Kerur, B.R.

    2010-01-01

    The mass attenuation coefficients of specific parts of several plants, (fruits, leaves, stem and seeds) often used as medicines in the Indian herbal system, have been measured employing NaI (TI)) detector. The electronic setup used is a NaI (TI) detector, which is coupled to MCA for analysis of the spectrum. A source of 241 Am is used to get X-rays in the energy range 8-32 keV from Cu, Rb, Mo, Ag and Ba targets. In the present study, the measured mass attenuation coefficient of Ocimum sanctum, Catharanthus roseus, Trigonella foenum-graecum, Azadirachta indica, Aegle marmelos, Zingiber officinalis, Emblica officinalis, Anacardium occidentale, Momordica charantia and Syzygium cumini show a linear relation with the energy.

  16. Semiempirical method of determining flow coefficients for pitot rake mass flow rate measurements

    Trefny, C. J.

    1985-01-01

    Flow coefficients applicable to area-weighted pitot rake mass flow rate measurements are presented for fully developed, turbulent flow in an annulus. A turbulent velocity profile is generated semiempirically for a given annulus hub-to-tip radius ratio and integrated numerically to determine the ideal mass flow rate. The calculated velocities at each probe location are then summed, and the flow rate as indicated by the rake is obtained. The flow coefficient to be used with the particular rake geometry is subsequently obtained by dividing the ideal flow rate by the rake-indicated flow rate. Flow coefficients ranged from 0.903 for one probe placed at a radius dividing two equal areas to 0.984 for a 10-probe area-weighted rake. Flow coefficients were not a strong function of annulus hub-to-tip radius ratio for rakes with three or more probes. The semiempirical method used to generate the turbulent velocity profiles is described in detail.

  17. Mass Transfer Coefficients and Bubble Sizes in Oxidative Ladle Refining of Silicon

    Bjørnstad, Erlend Lunnan

    2016-01-01

    The mass transfer of [Al] and [Ca] between three synthetic SiO_{2}-CaO-Al_{2}O_{3} slags, and 8N silicon, has been investigated to find the overall mass transfer coefficient k_{i,t} for the individual species. Samples were kept at 1873K for 5, 10, 20, 30 and 180min before quenching. The metal phase was later analyzed by ICP-MS to view how the concentrations of impurities change with respect to time. This work then compares these results to industrial data gathered from ladles used for oxidati...

  18. Measurement of photon mass attenuation coefficients of plutonium from 60 to 2615 keV

    Rettschlag, M.; Berndt, R.; Mortreau, P.

    2007-01-01

    Measurements have been made to determine plutonium photon mass attenuation coefficients by using a collimated-beam transmission method in the energy range from 60 to 2615 keV. These experimental results were compared with previous experimental and theoretical data. Good agreements are observed in the 240-800 keV energy range, whereas differences up to maximum 10% are observed out of these limits

  19. Effect of heat and mass transfer coefficients on the performance of automotive catalytic converters

    Shamim, T. [Michigan Univ., Dept. of Mechanical Engineering, Dearborn, MI (United States)

    2003-06-01

    This paper numerically investigates the role of heat and mass transfer coefficients on the performance of automotive catalytic converters, which are employed to reduce engine exhaust emissions. The pollutant conversion performance of a converter is influenced by a number of physical and chemical processes that take place in gaseous and solid phases as the exhaust gases flow through the catalyst. A quantitative predictive understanding of these complex catalyst processes involving flow dynamics, heterogeneous surface reactions and heat and mass transport mechanisms is important in improving the converter design. The role of convective transport phenomena becomes important at high temperature when the mass transfer becomes rate-limiting to an increasing extent. The objective of the present study is to elucidate the influence of convective heat and mass transfer coefficients (mechanisms). The mathematical model considers the conservation of mass, momentum and energy in both gaseous and solid phases. In addition to the heterogeneous surface reactions, the model also takes into account the adsorption/desorption of oxygen in the catalyst during non-stoichiometric composition of air/fuel mixtures. The governing equations are solved by an implicit scheme using a successive line under a relaxation method. The converter performance under the transient conditions as simulated by the US Federal Test Procedure (US-FTP) is analysed. (Author)

  20. Spectral slopes of the absorption coefficient of colored dissolved and detrital material inverted from UV-visible remote sensing reflectance.

    Wei, Jianwei; Lee, Zhongping; Ondrusek, Michael; Mannino, Antonio; Tzortziou, Maria; Armstrong, Roy

    2016-03-01

    The spectral slope of the absorption coefficient of colored dissolved and detrital material (CDM), S cdm (units: nm -1 ), is an important optical parameter for characterizing the absorption spectral shape of CDM. Although highly variable in natural waters, in most remote sensing algorithms, this slope is either kept as a constant or empirically modeled with multiband ocean color in the visible domain. In this study, we explore the potential of semianalytically retrieving S cdm with added ocean color information in the ultraviolet (UV) range between 360 and 400 nm. Unique features of hyperspectral remote sensing reflectance in the UV-visible wavelengths (360-500 nm) have been observed in various waters across a range of coastal and open ocean environments. Our data and analyses indicate that ocean color in the UV domain is particularly sensitive to the variation of the CDM spectral slope. Here, we used a synthesized data set to show that adding UV wavelengths to the ocean color measurements will improve the retrieval of S cdm from remote sensing reflectance considerably, while the spectral band settings of past and current satellite ocean color sensors cannot fully account for the spectral variation of remote sensing reflectance. Results of this effort support the concept to include UV wavelengths in the next generation of satellite ocean color sensors.

  1. Determination of the scattering coefficient of biological tissue considering the wavelength and absorption dependence of the anisotropy factor

    Fukutomi, Daichi; Ishii, Katsunori; Awazu, Kunio

    2016-04-01

    The anisotropy factor g, one of the optical properties of biological tissues, has a strong influence on the calculation of the scattering coefficient μ s in inverse Monte Carlo (iMC) simulations. It has been reported that g has the wavelength and absorption dependence; however, few attempts have been made to calculate μ s using g values by taking the wavelength and absorption dependence into account. In this study, the angular distributions of scattered light for biological tissue phantoms containing hemoglobin as a light absorber were measured by a goniometric optical setup at strongly (405 nm) and weakly (664 nm) absorbing wavelengths to obtain g. Subsequently, the optical properties were calculated with the measured values of g by integrating sphere measurements and an iMC simulation, and compared with the results obtained with a conventional g value of 0.9. The μ s values with measured g were overestimated at the strongly absorbing wavelength, but underestimated at the weakly absorbing wavelength if 0.9 was used in the iMC simulation.

  2. Experimental Determination of the Molar Absorption Coefficient of n-Hexane Adsorbed on High-Silica Zeolites.

    Gatti, Giorgio; Olivas Olivera, Diana F; Sacchetto, Vittoria; Cossi, Maurizio; Braschi, Ilaria; Marchese, Leonardo; Bisio, Chiara

    2017-09-06

    Determination of the molar absorption coefficients of the CH 3 bending mode at ν˜ =1380 cm -1 (ϵ 1380 ) of n-hexane adsorbed from the gas phase on two different dealuminated zeolites is derived by a combination of IR spectroscopy and microgravimetric analysis. High-silica zeolite Y (HSZ-Y) and zeolite ZSM-5 (with SiO 2 /Al 2 O 3 ratios of 200 and 280, respectively) with different textural and surface features are selected to evaluate the effect of the pore structure and architecture on the value of ϵ 1380 of the adsorbed n-hexane. Experimental data indicate that the molecule experiences a different adsorption environment inside zeolites; thus resulting in a significant change of the dipole moment and very different ϵ 1380 values: (0.278±0.018) cm μmol -1 for HSZ-Y and (0.491±0.032) cm μmol -1 for ZSM-5. Experimental data are also supported by computational modeling, which confirms the effect of different matrices on the IR absorption intensity. This study reveals that the use of probe molecules for quantitative measurements of surface sites has to be judiciously adopted, especially if adsorption occurs in the restricted spaces of microporous materials. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Light absorption coefficients by phytoplankton pigments, suspended particles and colored dissolved organic matter in the Crimea coastal water (the Black sea) in June 2016

    Moiseeva, N.; Churilova, T.; Efimova, T.; Krivenko, O.; Latushkin, A.

    2017-11-01

    Variability of the bio-optical properties of the Crimean coastal waters in June 2016 has been analyzed. The type of vertical distribution chlorophyll a concentration and phytoplankton light absorption coefficients and spectra shape differed between shallow and deeper water. In the deeper water seasonal stratification divided euphotic zone into layers with different environmental conditions. In the deeper part of the euphotic zone (below the thermocline) phytoplankton absorption spectra had local maximum at 550 nm, which was likely to be associated with high abundance of cyanobacteria (Synechococcus sps.) in the phytoplankton community. The concentration of chlorophyll a specific light absorption coefficient of phytoplankton decreased with depth (especially pronounced in the blue domain of the spectrum). In the shallow water the vertical distributions of all absorption properties were relatively homogeneous due to vertical water mixing. In the shallow water non-algal particles light absorption coefficient and its contribution to total particulate absorption were higher than those in the deeper water. The non-algal particles (NAP) and colored dissolved organic matter (CDOM) light absorption spectra were well described by an exponential function with a slope averaging 0.010 nm-1 (SD = 0.001 nm-1) and 0.022 nm-1 (SD = 0.0060 nm-1), correspondingly. The CDOM absorption at 440 nm and slope coefficient varied significantly across the investigated area, which was possibly associated with the terrestrial influences. The assessment of the contribution of phytoplankton, NAP and CDOM to total light absorption showed that CDOM dominated in the absorption at 440 nm.

  4. Distinct positive temperature coefficient effect of polymer-carbon fiber composites evaluated in terms of polymer absorption on fiber surface.

    Zhang, Xi; Zheng, Shaodi; Zheng, Xiaofang; Liu, Zhengying; Yang, Wei; Yang, Mingbo

    2016-03-21

    In this article, the positive temperature coefficient (PTC) effect was studied for high-density polyethylene (HDPE)/carbon fiber (CF) composites. All of the samples showed a significant PTC effect during the heating processes without a negative temperature coefficient (NTC) effect, even at a temperature much higher than the melting point of the polymer matrix. An ever-increasing PTC intensity with increasing thermal cycles was observed in our study that had never been reported in previous research. The absence of a NTC effect resulted from the increased binding force between the matrix and fillers that contributed to the very special structure of CF surface. We incorporated thermal expansion theory and quantum tunneling effects to explain PTC effect. From the SEM micrographs for the HDPE/CF composites before and after the different thermal cycles, we found that the surface of CF was covered with a layer of polymer which resulted in a change in the gap length between CF and HDPE and its distribution. We believed that the gap change induced by polymer absorption on the fiber surface had a great effect on the PTC effect.

  5. High accuracy experimental determination of copper and zinc mass attenuation coefficients in the 100 eV to 30 keV photon energy range

    Ménesguen, Y.; Gerlach, M.; Pollakowski, B.; Unterumsberger, R.; Haschke, M.; Beckhoff, B.; Lépy, M.-C.

    2016-02-01

    The knowledge of atomic fundamental parameters such as mass attenuation coefficients with low uncertainties, is of decisive importance in elemental quantification using x-ray fluorescence analysis techniques. Several databases are accessible and frequently used within a large community of users. These compilations are most often in good agreement for photon energies in the hard x-ray ranges. However, they significantly differ for low photon energies and around the absorption edges of any element. In a joint cooperation of the metrology institutes of France and Germany, mass attenuation coefficients of copper and zinc were determined experimentally in the photon energy range from 100 eV to 30 keV by independent approaches using monochromatized synchrotron radiation at SOLEIL (France) and BESSY II (Germany), respectively. The application of high-accuracy experimental techniques resulted in mass attenuation coefficient datasets determined with low uncertainties that are directly compared to existing databases. The novel datasets are expected to enhance the reliability of mass attenuation coefficients.

  6. Mass transfer coefficient in ginger oil extraction by microwave hydrotropic solution

    Handayani, Dwi; Ikhsan, Diyono; Yulianto, Mohamad Endy; Dwisukma, Mandy Ayulia

    2015-12-01

    This research aims to obtain mass transfer coefficient data on the extraction of ginger oil using microwave hydrotropic solvent as an alternative to increase zingiberene. The innovation of this study is extraction with microwave heater and hydrotropic solvent,which able to shift the phase equilibrium, and the increasing rate of the extraction process and to improve the content of ginger oil zingiberene. The experiment was conducted at the Laboratory of Separation Techniques at Chemical Engineering Department of Diponegoro University. The research activities carried out in two stages, namely experimental and modeling work. Preparation of the model postulated, then lowered to obtain equations that were tested and validated using data obtained from experimental. Measurement of experimental data was performed using microwave power (300 W), extraction temperature of 90 ° C and the independent variable, i.e.: type of hydrotropic, the volume of solvent and concentration in order, to obtain zingiberen levels as a function of time. Measured data was used as a tool to validate the postulation, in order to obtain validation of models and empirical equations. The results showed that the mass transfer coefficient (Kla) on zingiberene mass transfer models ginger oil extraction at various hydrotropic solution attained more 14 ± 2 Kla value than its reported on the extraction with electric heating. The larger value of Kla, the faster rate of mass transfer on the extraction process. To obtain the same yields, the microwave-assisted extraction required one twelfth time shorter.

  7. Study of coupled heat and mass transfer during absorption of ...

    (iii) The gas phase is ideal from thermodynamic point of view. (iv) Only mass transfer and no heat transfer takes place through the porous filter. (v) The thermal conductivity and specific heat of the hydride bed are assumed to be constant. This assumption underestimates the bed performance slightly, because in actual case ...

  8. Study of coupled heat and mass transfer during absorption of ...

    2.3 Hydrogen mass balance ε. ∂ρg. ∂t. + div(ρgVg) ... staggered grids to catch the heat transfer across the control volume by convection effectively. .... temperature decreases due to fall in the reaction rate and increase in heat transfer from the.

  9. The Mass and Absorption Columns of Galactic Gaseous Halos

    Qu, Zhijie; Bregman, Joel N.

    2018-01-01

    The gaseous halo surrounding the galaxy is a reservoir for the gas on the galaxy disk, supplying materials for the star formation. We developed a gaseous halo model connecting the galactic disk and the gaseous halo by assuming the star formation rate is equal to the radiative cooling rate. Besides the single-phase collisional gaseous halo, we also consider the photoionization effect and a time-independent cooling model that assumes the mass cooling rate is constant over all temperatures. The photoionization dominates the low mass galaxy and the outskirts of the massive galaxy due to the low-temperature or low-density nature. The multi-phase cooling model dominates the denser region within the cooling radius, where the efficient radiative cooling must be included. Applying these two improvements, our model can reproduce the most of observed high ionization state ions (i.e., O VI, O VII, Ne VIII and Mg X). Our models show that the O VI column density is almost a constant of around 10^14 cm^-2 over a wide stellar mass from M_\\star ~10^8 M_Sun to 10^11 M_Sun, which is constant with current observations. This model also implies the O VI is photoionized for the galaxy with a halo mass fraction function of the EAGLE simulation. Finally, our model predicts plateaus of the Ne VIII and the Mg X column densities above the sub-L^* galaxy, and the possibly detectable O VII and O VIII column densities for low-mass galaxies, which help to determine the required detection limit for the future observations and missions.

  10. Dose Rate and Mass Attenuation Coefficients of Gamma Ray for Concretes

    Abdel-Latif, A A; Kansouh, W A; El-Sayed, F H

    2003-01-01

    This work is concerned with the study of the leakage gamma ray dose and mass attenuation coefficients for ordinary, basalt and dolomite concretes made from local ores. Concretes under investigation were constructed from gravel, basalt and dolomite ores, and then reconstructed with the addition of 3% steel fibers by weight. Measurements were carried out using a collimated beam from sup 6 sup 0 Co gamma ray source and sodium iodide (3x3) crystal with the genie 2000 gamma spectrometer. The obtained fluxes were transformed to gamma ray doses and displayed in the form of gamma ray dose rates distribution. The displayed curves were used to estimate the linear attenuation coefficients (mu), the relaxation lengths (lambda), half value layer (t sub 1 /2) and tenth value layer (t sub 1 /10). Also, The total mass attenuation coefficients of gamma ray have been calculated to the concerned concretes using XCOM (version 3.1) program and database elements cross sections from Z=1 to 100 at energies from 10 keV to 100 MeV. In...

  11. Non-equilibrium mass transfer absorption model for the design of boron isotopes chemical exchange column

    Bai, Peng; Fan, Kaigong; Guo, Xianghai; Zhang, Haocui

    2016-01-01

    Highlights: • We propose a non-equilibrium mass transfer absorption model instead of a distillation equilibrium model to calculate boron isotopes separation. • We apply the model to calculate the needed column height to meet prescribed separation requirements. - Abstract: To interpret the phenomenon of chemical exchange in boron isotopes separation accurately, the process is specified as an absorption–reaction–desorption hybrid process instead of a distillation equilibrium model, the non-equilibrium mass transfer absorption model is put forward and a mass transfer enhancement factor E is introduced to find the packing height needed to meet the specified separation requirements with MATLAB.

  12. Analysis of the behavior of an experimental absorption heat transformer for water purification for different mass flux rates in the generator

    Huicochea, Armando; Rivera, Wilfrido; Martínez, Hiram; Siqueiros, Javier; Cadenas, Erasmo

    2013-01-01

    In the present study, first and second laws of thermodynamics have been used to analyse the performance of an experimental absorption heat transformer for water purification. Irreversibilities, coefficients of performance (COP) and exergy coefficients of performance (ECOP) were determined as function of the mass flow of hot water supplied to the generator and as function of the overall thermal specific energy consumption (OSTEC) parameter defined in this paper. The results showed that the system irreversibilities increase meanwhile the coefficients of performance and the exergy coefficient of performance decrease with an increment of the mass flow of hot water supplied to the generator. Also it was shown that the system performance is better when the production of purified water increases due to the increment of the heat recycled to the generator and evaporator. -- Highlights: ► Exergetic performance of an absorption heat transformer for purifying water to different mass flux rates in the generator. ► The irreversibilities are increasing when the mass flow rate in the generator is major. ► The mass flow rates in the generator plays a decisive role in the whole system efficiency

  13. Simultaneous measurement of thermal diffusivity and effective infrared absorption coefficient in IR semitransparent and semiconducting n-CdMgSe crystals using photothermal radiometry

    Pawlak, M., E-mail: mpawlak@fizyka.umk.pl [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziądzka 5/7, Toruń (Poland); Maliński, M. [Department of Electronics and Computer Science, Koszalin University of Technology, 2 Śniadeckich St., Koszalin 75-453 (Poland)

    2015-01-10

    Highlights: • The new method of determination of the effective infrared absorption coefficient is presented. • The method can be used for transparent samples for the excitation radiation. • The effect of aluminum foil on the PTR signal in a transmission configuration is discussed. - Abstract: In this paper we propose a new procedure of simultaneous estimation of the effective infrared optical absorption coefficient and the thermal diffusivity of solid state samples using the photothermal infrared radiometry method in the transmission configuration. The proposed procedure relies on the analysis of the frequency dependent signal obtained from the samples covered with thin aluminum foil. This method can be applied for both optically opaque and transparent samples. The proposed method is illustrated with the results of the thermal diffusivity and the effective IR absorption coefficient obtained for several Cd{sub 1−x}Mg{sub x}Se crystals.

  14. Near-unity mass accommodation coefficient of organic molecules of varying structure.

    Julin, Jan; Winkler, Paul M; Donahue, Neil M; Wagner, Paul E; Riipinen, Ilona

    2014-10-21

    Atmospheric aerosol particles have a significant effect on global climate, air quality, and consequently human health. Condensation of organic vapors is a key process in the growth of nanometer-sized particles to climate relevant sizes. This growth is very sensitive to the mass accommodation coefficient α, a quantity describing the vapor uptake ability of the particles, but knowledge on α of atmospheric organics is lacking. In this work, we have determined α for four organic molecules with diverse structural properties: adipic acid, succinic acid, naphthalene, and nonane. The coefficients are studied using molecular dynamics simulations, complemented with expansion chamber measurements. Our results are consistent with α = 1 (indicating nearly perfect accommodation), regardless of the molecular structural properties, the phase state of the bulk condensed phase, or surface curvature. The results highlight the need for experimental techniques capable of resolving the internal structure of nanoparticles to better constrain the accommodation of atmospheric organics.

  15. Heat and mass transfer coefficients and modeling of infrared drying of banana slices

    Fernanda Machado Baptestini

    Full Text Available ABSTRACT Banana is one of the most consumed fruits in the world, having a large part of its production performed in tropical countries. This product possesses a wide range of vitamins and minerals, being an important component of the alimentation worldwide. However, the shelf life of bananas is short, thus requiring procedures to prevent the quality loss and increase the shelf life. One of these procedures widely used is drying. This work aimed to study the infrared drying process of banana slices (cv. Prata and determine the heat and mass transfer coefficients of this process. In addition, effective diffusion coefficient and relationship between ripening stages of banana and drying were obtained. Banana slices at four different ripening stages were dried using a dryer with infrared heating source with four different temperatures (65, 75, 85, and 95 ºC. Midilli model was the one that best represented infrared drying of banana slices. Heat and mass transfer coefficients varied, respectively, between 46.84 and 70.54 W m-2 K-1 and 0.040 to 0.0632 m s-1 for temperature range, at the different ripening stages. Effective diffusion coefficient ranged from 1.96 to 3.59 × 10-15 m² s-1. Activation energy encountered were 16.392, 29.531, 23.194, and 25.206 kJ mol-1 for 2nd, 3rd, 5th, and 7th ripening stages, respectively. Ripening stages did not affect the infrared drying of bananas.

  16. Kaon mass by critical absorption of kaonic atom x rays

    Lum, G.K.

    1979-10-01

    The energy of the kaonic 6h → 5g transition has been determined using the calculated μ/rho curve. Because the detectors used could not resolve the noncircular transitions, the predictions from a calculated cascade program were used. According to the cascade results for potassium, the number of noncircular x-rays was about 10% of all the transitions between n = 6 to n = 5. Based on the available information, the mass of the kaon was measured to be 493.576/sub -0.069//sup +0.044/ MeV

  17. Three loop massive operator matrix elements and asymptotic Wilson coefficients with two different masses

    Ablinger, J.; Hasselhuhn, A.; Schneider, C. [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC); Bluemlein, J.; Freitas, A. de [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Wissbrock, F. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC); IHES, Bures-sur-Yvette (France)

    2017-05-15

    Starting at 3-loop order, the massive Wilson coefficients for deep-inelastic scattering and the massive operator matrix elements describing the variable flavor number scheme receive contributions of Feynman diagrams carrying quark lines with two different masses. In the case of the charm and bottom quarks, the usual decoupling of one heavy mass at a time no longer holds, since the ratio of the respective masses, η=m{sup 2}{sub c}/m{sup 2}{sub b}∝1/10, is not small enough. Therefore, the usual variable flavor number scheme (VFNS) has to be generalized. The renormalization procedure in the two-mass case is different from the single mass case derived earlier (I. Bierenbaum, J: Bluemlein, S. Klein, 2009). We present the moments N=2,4 and 6 for all contributing operator matrix elements, expanding in the ratio η. We calculate the analytic results for general values of the Mellin variable N in the flavor non-singlet case, as well as for transversity and the matrix element A{sup (3)}{sub gq}. We also calculate the two-mass scalar integrals of all topologies contributing to the gluonic operator matrix element A{sub gg}. As it turns out, the expansion in η is usually inapplicable for general values of N. We therefore derive the result for general values of the mass ratio. From the single pole terms we derive, now in a two-mass calculation, the corresponding contributions to the 3-loop anomalous dimensions. We introduce a new general class of iterated integrals and study their relations and present special values. The corresponding functions are implemented in computer-algebraic form.

  18. Three loop massive operator matrix elements and asymptotic Wilson coefficients with two different masses

    J. Ablinger

    2017-08-01

    Full Text Available Starting at 3-loop order, the massive Wilson coefficients for deep-inelastic scattering and the massive operator matrix elements describing the variable flavor number scheme receive contributions of Feynman diagrams carrying quark lines with two different masses. In the case of the charm and bottom quarks, the usual decoupling of one heavy mass at a time no longer holds, since the ratio of the respective masses, η=mc2/mb2∼1/10, is not small enough. Therefore, the usual variable flavor number scheme (VFNS has to be generalized. The renormalization procedure in the two-mass case is different from the single mass case derived in [1]. We present the moments N=2,4 and 6 for all contributing operator matrix elements, expanding in the ratio η. We calculate the analytic results for general values of the Mellin variable N in the flavor non-singlet case, as well as for transversity and the matrix element Agq(3. We also calculate the two-mass scalar integrals of all topologies contributing to the gluonic operator matrix element Agg. As it turns out, the expansion in η is usually inapplicable for general values of N. We therefore derive the result for general values of the mass ratio. From the single pole terms we derive, now in a two-mass calculation, the corresponding contributions to the 3-loop anomalous dimensions. We introduce a new general class of iterated integrals and study their relations and present special values. The corresponding functions are implemented in computer-algebraic form.

  19. Mass transfer coefficient factor in pipe bend - 3 D CFD analysis

    Prasad, Mahendra; Gaikwad, Avinash J.; Madasamy, P.; Krishnamohan, T.V.; Velumurugan, S.; Sridharan, Arunkumar; Parida, Smrutiranjan

    2015-01-01

    In power industries Flow Accelerated Corrosion (FAC) has been a concern for pipe wall thinning where high velocity fluid at elevated temperatures is used. Even straight pipes are found to have non uniform corrosion and this is enhanced in junctions such as bends, orifices etc. Mass transfer coefficient (MTC) which defines the amount of corrosion changes from its value in straight pipe (with same fluid parameters) for flow in bends, orifice etc due to changes in velocity profile in axial direction. In this paper, 3 D computational fluid dynamics (CFD) simulation is carried out for an experiment on 58° bend angle and 2D bend radius circular carbon steel pipe carrying water at 120°C under neutral pH conditions. The turbulent model K-ω with shear stress transport was used for this purpose. The mass transfer boundary layer (MTBL) thickness δ mtbl depends on Schmidt number (Sc), as δ mtbl ∼ δ h /(Sc 1/3 ). MTBL is significantly smaller than hydrodynamic boundary layer δ h for large Sc, hence boundary layer meshing was carried out deep into δ mtbl . Uniform velocity was applied at the inlet. The flow velocity was 3 m/s at room temperature while the experimental fluid velocity was 7 m/s. Lower value of fluid velocity is chosen due to the limitations of grid size since it depends inversely on fluid velocity. The ratio of MTC in bend to straight pipe is not strongly dependent on Sc. CFD simulation at lower temperature is sufficient to get approximate MTC in bends. The ratio of the mass transfer coefficient at some locations in bend to the straight pipe coefficient (MTCR) is determined through simulation. The MTC increased in the extrados of the bend towards the outlet. (author)

  20. Comparison of Theoretical and Experimental Mass Transfer Coefficients of Gases in Supported Ionic Liquid Membranes

    Kárászová, Magda; Šimčík, Miroslav; Friess, K.; Randová, A.; Jansen, J. C.; Růžička, Marek; Sedláková, Zuzana; Izák, Pavel

    2013-01-01

    Roč. 118, 30 OCT (2013), s. 255-263 ISSN 1383-5866 R&D Projects: GA ČR GAP106/10/1194; GA MŠk(CZ) 7C11009 Grant - others:RFCS(XE) RFCR-CT-2010-00009; INP(IT) PON01_01840; HA MŠk(CZ) CZ.1.05/2.1.00/03.0071 Institutional support: RVO:67985858 Keywords : biogas purification * supported ionic liquid membranes * mass transfer coefficients Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.065, year: 2013

  1. Landsat-8/OLI images has the potential to estimate the CDOM absorption coefficient in tropical inland water

    Alcantara, E.; Bernardo, N.

    2016-12-01

    Colored dissolved organic matter (CDOM) is the most abundant dissolved organic matter (DOM) in many natural waters and can affect the water quality, such as the light penetration and the thermal properties of water system. So the objective of this letter was to estimate the colored dissolved organic matter (CDOM) absorption coefficient at 440 nm, aCDOM(440), in Barra Bonita Reservoir (São Paulo State, Brazil) using OLI/Landsat-8 images. For this two field campaigns were conducted in May and October 2014. During the field campaigns remote sensing reflectance (Rrs) were measured using a TriOS hyperspectral radiometer. Water samples were collected and analyzed to obtain the aCDOM(440). To predict the aCDOM(440) from Rrs at two key wavelengths (650 and 480 nm) were regressed against laboratory derived aCDOM(440) values. The validation using in situ data of aCDOM(440) algorithm indicated a goodness of fit, R2 = 0.70, with a root-mean-square error (RMSE) of 10.65%. The developed algorithm was applied to the OLI/Lansat-8 images. Distribution maps were created with OLI/Landsat-8 images based on the adjusted algorithm.

  2. Ozone mass transfer behaviors on physical and chemical absorption for hollow fiber membrane contactors.

    Zhang, Yong; Li, Kuiling; Wang, Jun; Hou, Deyin; Liu, Huijuan

    2017-09-01

    To understand the mass transfer behaviors in hollow fiber membrane contactors, ozone fluxes affected by various conditions and membranes were investigated. For physical absorption, mass transfer rate increased with liquid velocity and the ozone concentration in the gas. Gas flow rate was little affected when the velocity was larger than the critical value, which was 6.1 × 10 -3 m/s in this study. For chemical absorption, the flux was determined by the reaction rate between ozone and the absorbent. Therefore, concentration, species, and pH affected the mass transfer process markedly. For different absorbents, the order of mass transfer rate was the same as the reaction rate constant, which was phenol, sodium nitrite, hydrogen peroxide, and oxalate. Five hydrophobic membranes with various properties were employed and the mass transfer behavior can be described by the Graetz-Lévèque equation for the physical absorption process. The results showed the process was controlled by liquid film and the gas phase conditions, and membrane properties did not affect the ozone flux. For the chemical absorption, gas film, membrane and liquid film affected the mass transfer together, and none of them were negligible.

  3. Experimental study of convective coefficient of mass transfer of avocado (Persia americana Mill.)

    Alves, Suerda Bezerra; Luiz, Marcia Ramos; Amorim, Joselma Araujo de; Gusmao, Rennam Pereira de; Gurgel, Jose Mauricio [Universidade Federal da Paraiba (LES/UFPB), Joao Pessoa, PB (Brazil). Lab. de Energia Solar

    2010-07-01

    Most of all energy consumed worldwide comes from fossil fuels derived from petroleum. With the petroleum crisis in the 70 were sought new energy sources, among them renewable. One such source is biodiesel energy, organic matter originated from animal and/or vegetable. Among the various plant species is the avocado (Persia americana Mill.) showing great potential in the production of petroleum extracted from the pulp and the alcohol removed from the seed. The main obstacle for obtaining the petroleum is the high humidity found in the pulp, being necessary to the drying process, which involves the transfer of heat and mass. The aim of this study was to use the mathematical model represented by Newton's Law of Cooling to simulate the mass transfer on the surface of the avocado pulp during the drying process. The equation of the mathematical model was solved numerically and the method of least squares was identified convective coefficient of Mass Transfer. The dryer used in the experimental process was operated with air flow in the vertical, air flow average fixed 3m/s and temperatures of 50, 60 and 70 deg C. The scheme of the dryer used in the research is composed of the following equipment: centrifugal fan, which drives the air-drying; valve, which allows control of airflow; electrical resistance, used for heating air; the drying chamber, where enables measurement of temperature and relative humidity; support for smaller trays; trays smaller, where the samples of the pulp of the avocado are placed; exit of the air of drying for the environment. The result presented shows the ratio of moisture content as a function of temperature over time, where it is possible to also observe that how much bigger the temperature of drying, greater will be the convective coefficient of mass transfer of the avocado. (author)

  4. Assessment of Mass Transfer Coefficients in Coalescing Slug Flow in Vertical Pipes and Applications to Tubular Airlift Membrane Bioreactors

    Ratkovich, Nicolas Rios; Berube, P.R.; Nopens, I.

    2011-01-01

    by the gas flow. It was noted that coalescence of bubbles affects the MTH. Coalescence increased the “width” of the peaks (i.e. the estimate of the variability of the mass transfer coefficient) and the height of the peak (i.e. amount of time that a mass transfer coefficient of a given value is maintained......). A semi-empirical relationship based on the Lévêque relationship for the Sherwood number (mass transfer coefficient) was formulated for the laminar regime. A test case comparison between water and activated sludge was performed based on full-scale airlift MBR operational conditions. It was found...

  5. Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

    Fukuda, Makoto; Yoshimura, Kengo; Namekawa, Koki; Sakai, Kiyotaka

    2017-06-01

    The objective of the present study is to evaluate the effect of filtration coefficient and internal filtration on dialysis fluid flow and mass transfer coefficient in dialyzers using dimensionless mass transfer correlation equations. Aqueous solution of vitamin B 12 clearances were obtained for REXEED-15L as a low flux dialyzer, and APS-15EA and APS-15UA as high flux dialyzers. All the other design specifications were identical for these dialyzers except for filtration coefficient. The overall mass transfer coefficient was calculated, moreover, the exponents of Reynolds number (Re) and film mass transfer coefficient of the dialysis-side fluid (k D ) for each flow rate were derived from the Wilson plot and dimensionless correlation equation. The exponents of Re were 0.4 for the low flux dialyzer whereas 0.5 for the high flux dialyzers. Dialysis fluid of the low flux dialyzer was close to laminar flow because of its low filtration coefficient. On the other hand, dialysis fluid of the high flux dialyzers was assumed to be orthogonal flow. Higher filtration coefficient was associated with higher k D influenced by mass transfer rate through diffusion and internal filtration. Higher filtration coefficient of dialyzers and internal filtration affect orthogonal flow of dialysis fluid.

  6. Hydrotropic effect and thermodynamic analysis on the solubility and mass transfer coefficient enhancement of ethylbenzene

    Morais, Antony Bertie; Jayakumar, Chinnakannu; Gandhi, Nagarajan Nagendra

    2013-01-01

    Concentrated aqueous solutions of a large number of hydrotropic agents, urea, nicotinamide, and sodium salicylate, have been employed to enhance the aqueous solubilities of poorly water soluble organic compounds. The influence of a wide range of hydrotrope concentrations (0-3.0mol·L"−"1) and different system temperatures (303-333 K) on the solubility of ethylbenzene has been studied. The solubility of ethylbenzene increases with increase in hydrotrope concentration and also with system temperature. Consequent to the increase in the solubility of ethylbenzene, the mass transfer coefficient was also found to increase with increase in hydrotrope concentration at 303 K. The enhancement factor, which is the ratio of the value in the presence and absence of a hydrotrope, is reported for both solubility and mass transfer coefficient of ethylbenzene. The Setschenow constant, K_s, a measure of the effectiveness of a hydrotrope, was determined for each case. To ascertain the hydrotropic aggregation behavior of ethylbenzene, thermodynamic parameters such as Gibb’s free energy, enthalpy, and entropy of ethylbenzene were determined

  7. Hydrotropic effect and thermodynamic analysis on the solubility and mass transfer coefficient enhancement of ethylbenzene

    Morais, Antony Bertie; Jayakumar, Chinnakannu; Gandhi, Nagarajan Nagendra [Anna University, Chennai (India)

    2013-04-15

    Concentrated aqueous solutions of a large number of hydrotropic agents, urea, nicotinamide, and sodium salicylate, have been employed to enhance the aqueous solubilities of poorly water soluble organic compounds. The influence of a wide range of hydrotrope concentrations (0-3.0mol·L{sup −1}) and different system temperatures (303-333 K) on the solubility of ethylbenzene has been studied. The solubility of ethylbenzene increases with increase in hydrotrope concentration and also with system temperature. Consequent to the increase in the solubility of ethylbenzene, the mass transfer coefficient was also found to increase with increase in hydrotrope concentration at 303 K. The enhancement factor, which is the ratio of the value in the presence and absence of a hydrotrope, is reported for both solubility and mass transfer coefficient of ethylbenzene. The Setschenow constant, K{sub s}, a measure of the effectiveness of a hydrotrope, was determined for each case. To ascertain the hydrotropic aggregation behavior of ethylbenzene, thermodynamic parameters such as Gibb’s free energy, enthalpy, and entropy of ethylbenzene were determined.

  8. Entrainment coefficient and effective mass for conduction neutrons in neutron star crust: simple microscopic models

    Carter, Brandon; Chamel, Nicolas; Haensel, Pawel

    2005-01-01

    In the inner crust of a neutron star, at densities above the 'drip' threshold, unbound 'conduction' neutrons can move freely past through the ionic lattice formed by the nuclei. The relative current density ni=nv-bar i of such conduction neutrons will be related to the corresponding mean particle momentum pi by a proportionality relation of the form ni=Kpi in terms of a physically well defined mobility coefficient K whose value in this context has not been calculated before. Using methods from ordinary solid state and nuclear physics, a simple quantum mechanical treatment based on the independent particle approximation, is used here to formulate K as the phase space integral of the relevant group velocity over the neutron Fermi surface. The result can be described as an 'entrainment' that changes the ordinary neutron mass m to a macroscopic effective mass per neutron that will be given-subject to adoption of a convention specifying the precise number density n of the neutrons that are considered to be 'free'-by m-bar =n/K. The numerical evaluation of the mobility coefficient is carried out for nuclear configurations of the 'lasagna' and 'spaghetti' type that may be relevant at the base of the crust. Extrapolation to the middle layers of the inner crust leads to the unexpected prediction that m-bar will become very large compared with m

  9. Mass transfer coefficient of slug flow for organic solvent-aqueous system in a microreactor

    Tuek, Ana Jurinjak; Anic, Iva; Kurtanjek, Zelimir; Zelic, Bruno [University of Zagreb, Zagreb (Croatia)

    2015-06-15

    Application of microreactor systems could be the next break-through in the intensification of chemical and biochemical processes. The common flow regime for organic solvent-aqueous phase two-phase systems is a segmented flow. Internal circulations in segments cause high mass transfer and conversion. We analyzed slug flow in seven systems of organic solvents and aqueous phase. To analyze how slug lengths in tested systems depend on linear velocity and physical and chemical properties of used organic solvents, regression models were proposed. It was shown that models based on linearization of approximation by potentials give low correlation for slug length prediction; however, application of an essential nonlinear model of multiple layer perception (MLP) neural network gives high correlation with R{sup 2}=0.9. General sensitivity analysis was applied for the MLP neural network model, which showed that 80% of variance in slug length for the both phases is accounted for the viscosity and density of the organic phases; 10% is accounted by surface tension of the organic phase, while molecular masses and flow rates each account for 5%. For defined geometry of microreactor, mass transfer has been determined by carrying out the neutralization experiment with NaOH where acetic acid diffuses from organic phase (hexane) into aqueous phase. Estimated mass transfer coefficients were in the range k{sub L}a=4,652-1,9807 h{sup -1}.

  10. Mass transfer coefficient of slug flow for organic solvent-aqueous system in a microreactor

    Tuek, Ana Jurinjak; Anic, Iva; Kurtanjek, Zelimir; Zelic, Bruno

    2015-01-01

    Application of microreactor systems could be the next break-through in the intensification of chemical and biochemical processes. The common flow regime for organic solvent-aqueous phase two-phase systems is a segmented flow. Internal circulations in segments cause high mass transfer and conversion. We analyzed slug flow in seven systems of organic solvents and aqueous phase. To analyze how slug lengths in tested systems depend on linear velocity and physical and chemical properties of used organic solvents, regression models were proposed. It was shown that models based on linearization of approximation by potentials give low correlation for slug length prediction; however, application of an essential nonlinear model of multiple layer perception (MLP) neural network gives high correlation with R 2 =0.9. General sensitivity analysis was applied for the MLP neural network model, which showed that 80% of variance in slug length for the both phases is accounted for the viscosity and density of the organic phases; 10% is accounted by surface tension of the organic phase, while molecular masses and flow rates each account for 5%. For defined geometry of microreactor, mass transfer has been determined by carrying out the neutralization experiment with NaOH where acetic acid diffuses from organic phase (hexane) into aqueous phase. Estimated mass transfer coefficients were in the range k L a=4,652-1,9807 h -1

  11. Study of oxygen mass transfer coefficient and oxygen uptake rate in a stirred tank reactor for uranium ore bioleaching

    Zokaei-Kadijani, S.; Safdari, J.; Mousavian, M.A.; Rashidi, A.

    2013-01-01

    Highlights: ► Mass transfer coefficient does not depend on biomass concentration. ► The pulp density has a negative effect on mass transfer coefficient. ► The pulp density is the unique factor that affects maximum OUR. ► In this work, Neale’s correlation is corrected for prediction of mass transfer coefficient. ► Biochemical reaction is a limiting factor in the uranium bioleaching process. - Abstract: In this work, the volumetric oxygen mass transfer coefficient and the oxygen uptake rate (OUR) were studied for uranium ore bioleaching process by Acidthiobacillus ferrooxidans in a stirred tank reactor. The Box-Bohnken design method was used to study the effect of operating parameters on the oxygen mass transfer coefficient. The investigated factors were agitation speed (rpm), aeration rate (vvm) and pulp density (% weight/volume) of the stirred tank reactor. Analysis of experimental results showed that the oxygen mass transfer coefficient had low dependence on biomass concentration but had higher dependence on the agitation speed, aeration rate and pulp density. The obtained biological enhancement factors were equal to ones in experiments. On the other hand, the obtained values for Damkohler number (Da < 0.468) indicated that the process was limited by the biochemical reaction rate. Experimental results obtained for oxygen mass transfer coefficient were correlated with the empirical relations proposed by Garcia-Ochoa and Gomez (2009) and Neale and Pinches (1994). Due to the high relative error in the correlation of Neale and Pinches, that correlation was corrected and the coefficient of determination was calculated to be 89%. The modified correlation has been obtained based on a wide range of operating conditions, which can be used to determine the mass transfer coefficient in a bioreactor

  12. Mass diffusion coefficient measurement for vitreous humor using FEM and MRI

    Rattanakijsuntorn, Komsan; Penkova, Anita; Sadha, Satwindar S.

    2018-01-01

    In early studies, the ‘contour method’ for determining the diffusion coefficient of the vitreous humor was developed. This technique relied on careful injection of an MRI contrast agent (surrogate drug) into the vitreous humor of fresh bovine eyes, and tracking the contours of the contrast agent in time. In addition, an analytical solution was developed for the theoretical contours built on point source model for the injected surrogate drug. The match between theoretical and experimental contours as a least square fit, while floating the diffusion coefficient, led to the value of the diffusion coefficient. This method had its limitation that the initial injection of the surrogate had to be spherical or ellipsoidal because of the analytical result based on the point-source model. With a new finite element model for the analysis in this study, the technique is much less restrictive and handles irregular shapes of the initial bolus. The fresh bovine eyes were used for drug diffusion study in the vitreous and three contrast agents of different molecular masses: gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA, 938 Da), non-ionic gadoteridol (Prohance, 559 Da), and bovine albumin conjugated with gadolinium (Galbumin, 74 kDa) were used as drug surrogates to visualize the diffusion process by MRI. The 3D finite element model was developed to determine the diffusion coefficients of these surrogates with the images from MRI. This method can be used for other types of bioporous media provided the concentration profile can be visualized (by methods such as MRI or fluorescence).

  13. Laboratory Measurements of Mass Specific Absorption Spectra for Suites of Black Carbon-like, Biomass Burning and Mineral Dust Aerosols

    Radney, J.; Zangmeister, C.

    2017-12-01

    Light-absorbing atmospheric aerosols can be grouped into three categories: black carbon (BC), brown carbon (BrC) or mineral dust (MD). In many cases, the absorption of these species is best quantified using a mass-specific absorption cross section (MAC) since the particles are in the Rayleigh regime (BC) or optically thin (BrC and MD); notably, MAC values are both traceable to the SI and transferrable between photoacoustic spectroscopy and filter-based absorption measurements. Here, we present laboratory measurements of MAC for all three light-absorbing aerosol classes. Particles were size- and mass-selected using a differential mobility analyzer and aerosol particle mass analyzer, respectively, with absorption coefficients (αabs) and number concentrations (N) being measured by a broadband photoacoustic spectrometer and condensation particle counter, respectively. This suite of instrumentation allows for direct quantification of MAC from the measured parameters (MAC = αabs/Nmp). Further, the measurements contained > 8 data points spanning λ = 405 nm to 840 nm allowing for spectral curvatures (i.e. the Absorption Angstrom Exponent or AAE) to be fit from many data points versus the more common 2-point interpolations. For the carbonaceous, BC-like aerosols - five samples generated from flames, spark discharge soot (i.e. fullerene soot), graphene, reduced graphene oxide (rGO), and fullerene (C60) - we found: 1) measured MAC ranged between 2.4 m2 g-1 and 8.6 m2 g-1 at λ = 550 nm, 2) most AAEs ranged between 0.5 and 1.3; C60 AAE was 7.5 ± 0.9 and 3) MAC spectra were dependent on fuel type and formation conditions. For BrC particles generated from smoldering combustion of 3 hardwood (Oak, Hickory and Mesquite) and 3 softwood species (Western redcedar, Blue spruce and Baldcypress), we found: 1) median MAC values ranged from 1.4 x 10-2 m2 g-1 to 7.9 x 10-2 m2 g-1 at λ = 550 nm, 2) AAE values ranged between 3.5 and 6.2, and 3) Oak, Western redcedar and Blue spruce

  14. Effect of intense high-frequency laser field on the linear and nonlinear intersubband optical absorption coefficients and refractive index changes in a parabolic quantum well under the applied electric field

    Yesilgul, U., E-mail: uyesilgul@cumhuriyet.edu.tr [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Ungan, F. [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Sakiroglu, S. [Dokuz Eylül University, Physics Department, 35160 Buca, İzmir (Turkey); Mora-Ramos, M.E. [Facultad de Ciencias Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, C.P. 62209 Cuernavaca, Morelos (Mexico); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Kasapoglu, E.; Sarı, H. [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Sökmen, I. [Dokuz Eylül University, Physics Department, 35160 Buca, İzmir (Turkey)

    2014-01-15

    The effects of the intense high-frequency laser field on the optical absorption coefficients and the refractive index changes in a GaAs/GaAlAs parabolic quantum well under the applied electric field have been investigated theoretically. The electron energy levels and the envelope wave functions of the parabolic quantum well are calculated within the effective mass approximation. Analytical expressions for optical properties are obtained using the compact density-matrix approach. The numerical results show that the intense high-frequency laser field has a large effect on the optical characteristics of these structures. Also we can observe that the refractive index and absorption coefficient changes are very sensitive to the electric field in large dimension wells. Thus, this result gives a new degree of freedom in the optoelectronic device applications. -- Highlights: • ILF has a large effect on the optical properties of parabolic quantum wells. • The total absorption coefficients increase as the ILF increases. • The RICs increase as the ILF increases.

  15. Experimental and theoretical determination of the absorption coefficients of X-rays through barium plaster from 100 to 400 keV

    Joksimovicj, V.

    1976-01-01

    The absorption coefficients of X-rays from 100 to 400 keV through barium plaster of equivalent atomic number of 26 have been determined experimentally and theoretically. Calculated values are compared with experimental data. Matrix components of barium plaster were determined chemically and by X-ray fluorescence

  16. Linear and nonlinear optical absorption coefficients in GaAs/Ga{sub 1-x}Al{sub x}As concentric double quantum rings: Effects of hydrostatic pressure and aluminum concentration

    Baghramyan, H.M. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Barseghyan, M.G., E-mail: mbarsegh@ysu.am [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Kirakosyan, A.A. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Restrepo, R.L. [Escuela de Ingenieria de Antioquia, AA 7516 Medellin (Colombia); Duque, C.A. [Instituto de Fisica, Universidad de Antioquia, AA 1226 Medellin (Colombia)

    2013-02-15

    The linear and nonlinear intra-band optical absorption coefficients in GaAs/Ga{sub 1-x}Al{sub x}As two-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and aluminum concentration the energies of the ground (n=1,l=0) and the first excited state (n=2,l=1) have been found using the effective mass approximation and the transfer matrix formalism. The energies of these states and the corresponding threshold energy of the intra-band optical transitions are examined as a function of hydrostatic pressure and aluminum concentration for different sizes of the structure. We also investigated the dependencies of the linear, nonlinear, and total optical absorption coefficients as functions of the incident photon energy for different values of hydrostatic pressure, aluminum concentration, sizes of the structure, and incident optical intensity. Its is found that the effects of the hydrostatic pressure and the aluminum concentration lead to a shifting of the resonant peaks of the intra-band optical spectrum. - Highlights: Black-Right-Pointing-Pointer Linear and nonlinear intra-band absorption in quantum rings. Black-Right-Pointing-Pointer Threshold energy strongly depends on the hydrostatic pressure. Black-Right-Pointing-Pointer Threshold energy strongly depends on the stoichiometry and sizes of structure. Black-Right-Pointing-Pointer Optical absorption is affected by the incident optical intensity.

  17. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    Ungan, F.; Restrepo, R.L.; Mora-Ramos, M.E.; Morales, A.L.; Duque, C.A.

    2014-01-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga 0.7 Al 0.3 As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga 0.7 Al 0.3 As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications

  18. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    Ungan, F., E-mail: fungan@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Restrepo, R.L. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Escuela de Ingeniería de Antioquia AA 7516, Medellín (Colombia); Mora-Ramos, M.E. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Facultad de Ciencias, Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Morales, A.L.; Duque, C.A. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2014-02-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications.

  19. Estimation of added-mass and damping coefficients of a tethered spherical float using potential flow theory

    Vethamony, P.; Chandramohan, P.; Sastry, J.S.; Narasimhan, S.

    Added-mass (alpha) and damping coefficients (beta) of a tethered spherical float, undergoing oscillatory motion in sinusoidal waves, have been derived from the motion generated velocity potential for one degree-of-freedom (surge) using potential...

  20. Mass transfer of SCWO processes: Molecular diffusion and mass transfer coefficients of inorganic nitrate species in sub- and supercritical water

    Goemans, M.G.E.; Gloyna, E.F. [Univ. of Texas, Austin, TX (United States). Dept. of Civil Engineering; Buelow, S.J. [Los Alamos National Lab., NM (United States)

    1996-04-01

    Molecular diffusion coefficients of lithium-, sodium-, potassium-, cesium-, calcium-, and strontium nitrate in subcritical water were determined by analysis of Taylor dispersion profiles. Pressures ranged from 300 to 500 bar at temperatures ranging from 25{degrees}C to 300{degrees}C. The reported diffusion values were determined at infinite dilution. Molecular diffusion coefficients were 10 to 20 times faster in near-critical subcritical water than in water at ambient temperature and pressure (ATP). These findings implied that the diffusion rates were more liquid like than they were gas like, hence experimental results were correlated with diffusion models for liquids. The subcritical diffusion data presented in this work, and supercritical diffusion results published elsewhere were correlated with hydrodynamic diffusion equations. Both the Wilke-Chang correlation and the Stokes-Einstein equation yielded predictions within 10% of the experimental results if the structure of the diffusing species could be estimated. The effect of the increased diffusion rates on mass transfer rates in supercritical water oxidation applications was quantified, with emphasis on heterogeneous oxidation processes. This study and results published elsewhere showed that diffusion limited conditions are much more likely to be encountered in SCWO processes than commonly acknowledged.

  1. Mass transfer and thermodynamic modeling of carbon dioxide absorption into MEA aqueous solution

    Ghaemi Ahad

    2017-09-01

    Full Text Available In this research, thermodynamic and absorption rate of carbon dioxide in monoethanolamine (MEA solution was investigated. A correlation based on both liquid and a gas phase variable for carbon dioxide absorption rate was presented using the π-Buckingham theorem. The correlation was constructed based on dimensionless numbers, including carbon dioxide loading, carbon dioxide partial pressure, film parameter and the ratio of liquid phase film thickness and gas phase film thickness. The film parameter is used to apply the effect of chemical reactions on absorption rate. A thermodynamic model based on the extended-UNIQUAC equations for the activity coefficients coupled with the Virial equation of state for representing the non-ideality of the vapor phase was used to predict the CO2 solubility in the CO2-MEA-H2O system. The average absolute error of the results for the correlation was 6.4%, which indicates the accuracy of the proposed correlation.

  2. Determination of mercury in hair: Comparison between gold amalgamation-atomic absorption spectrometry and mass spectrometry.

    Domanico, Francesco; Forte, Giovanni; Majorani, Costanza; Senofonte, Oreste; Petrucci, Francesco; Pezzi, Vincenzo; Alimonti, Alessandro

    2017-09-01

    Mercury is a heavy metal that causes serious health problems in exposed subjects. The most toxic form, i.e., methylmercury (MeHg), is mostly excreted through human hair. Numerous analytical methods are available for total Hg analysis in human hair, including cold vapour atomic fluorescence spectrometry (CV-AFS), inductively coupled plasma mass spectrometry (ICP-MS) and thermal decomposition amalgamation atomic absorption spectrometry (TDA-AAS). The aim of the study was to compare the TDA-AAS with the ICP-MS in the Hg quantification in human hair. After the washing procedure to minimize the external contamination, from each hair sample two aliquots were taken; the first was used for direct analysis of Hg by TDA-AAS and the second was digested for Hg determination by the ICP-MS. Results indicated that the two data sets were fully comparable (median; TDA-AAS, 475ngg -1 ; ICP-MS, 437ngg -1 ) and were not statistically different (Mann-Whitney test; p=0.44). The two techniques presented results with a good coefficient of correlation (r=0.94) despite different operative ranges and method limits. Both techniques satisfied internal performance requirements and the parameters for method validation resulting sensitive, precise and reliable. Finally, the use of the TDA-AAS can be considered instead of the ICP-MS in hair analysis in order to reduce sample manipulation with minor risk of contamination, less time consuming due to the absence of the digestion step and cheaper analyses. Copyright © 2016 Elsevier GmbH. All rights reserved.

  3. Novel and facile microwave-assisted synthesis of Mo-doped hydroxyapatite nanorods: Characterization, gamma absorption coefficient, and bioactivity.

    Abutalib, M M; Yahia, I S

    2017-09-01

    In the current work, the authors report the microwave-assisted synthesis Molybdenum-doped (from 0.05 to 5wt%) hydroxyapatite (HAp) for the first time. The morphology of Mo-doped HAp is nanorods of diameter in the range of 25-70nm and length in the range of 25nm to 200nm. The good crystalline nature was confirmed from X-ray diffraction patterns and also lattice parameters, grain size, strain and dislocation density were determined. The crystallite size was found to be in the range 16 to 30nm and crystallinity was found to be enhanced from 0.5 to 0.7 with doping. The field emission SEM micrographs show that the morphology of the synthesized nanostructures of pure and Mo-doped HAp are nanorods of few nanometers. The vibrational modes were identified using the FT-Raman and FT-IR spectroscopy. The dielectric properties were studied and the AC electrical conductivity was found to be increased with increasing the concentration of Mo ions doping in HAp. Moreover, antimicrobial studies were also carried out to understand the anti-bacterial and anti-fungi properties. The results suggest that it may be a good bio-ceramics material for bio-medical applications. Mo-doped HAp was subjected to the gamma irradiation produced from Cs-137 (662keV) and its related parameters such as linear absorption coefficient, the half-value layer (HVL) and the tenth value layer TVL were calculated and analyzed. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Assessment of natural radioactivity and mass attenuation coefficients of brick and roofing tile used in Turkey

    Damla, N.; Cevik, U.; Kobya, A.I.; Celik, A.; Celik, N.; Yildirim, I.

    2011-01-01

    In this study the distribution of natural radionuclides ( 226 Ra, 232 Th, 40 K) in brick and roofing tile samples commonly used as building materials in Turkey was measured by using gamma spectrometry. The activity concentrations, radium equivalent activities (Ra eq ), representative level index, indoor absorbed dose rate in air values and annual effective dose due to the intake of the above-mentioned radionuclides in the brick and roofing tile samples were estimated to assess the radiation hazard for people living in dwellings made of the materials studied. The measured average activity concentrations of 226 Ra, 232 Th and 40 K were 34 ± 14, 34 ± 13 and 462 ± 175 Bq.kg -1 , respectively, for brick samples. For roofing tile, the average activity concentrations of 226 Ra, 232 Th and 40 K were measured to be 34 ± 14, 33 ± 12 and 429 ± 161 Bq.kg -1 , respectively. The concentrations for these natural radionuclides were compared with the reported data of other countries. The Ra eq values of all samples were lower than the limit of 370 Bq.kg -1 , equivalent to a gamma dose of 1.5 mSv.a -1 recommended by OECD. This study shows that the measured brick and roofing tile samples do not pose any significant source of radiation hazard and are safe to be used as building materials. Moreover, the experimental mass attenuation coefficients (μ/ρ) of brick and roofing tile samples were determined in the energy range 80-1332 keV using the gamma ray transmission method. The experimental mass attenuation coefficients were compared with theoretical values obtained using XCOM. It was found that the computed values and the experimental results of this work are in good agreement with those reported in the literature. The chemical compositions and structural analysis (XRD) of the brick and roofing tile samples are also presented. - Highlights: → In this study, the distribution of natural radionuclides in brick and roofing tile samples used in Turkey were studied. → Associated

  5. Effects of reservoir heterogeneity on scaling of effective mass transfer coefficient for solute transport

    Leung, Juliana Y.; Srinivasan, Sanjay

    2016-09-01

    Modeling transport process at large scale requires proper scale-up of subsurface heterogeneity and an understanding of its interaction with the underlying transport mechanisms. A technique based on volume averaging is applied to quantitatively assess the scaling characteristics of effective mass transfer coefficient in heterogeneous reservoir models. The effective mass transfer coefficient represents the combined contribution from diffusion and dispersion to the transport of non-reactive solute particles within a fluid phase. Although treatment of transport problems with the volume averaging technique has been published in the past, application to geological systems exhibiting realistic spatial variability remains a challenge. Previously, the authors developed a new procedure where results from a fine-scale numerical flow simulation reflecting the full physics of the transport process albeit over a sub-volume of the reservoir are integrated with the volume averaging technique to provide effective description of transport properties. The procedure is extended such that spatial averaging is performed at the local-heterogeneity scale. In this paper, the transport of a passive (non-reactive) solute is simulated on multiple reservoir models exhibiting different patterns of heterogeneities, and the scaling behavior of effective mass transfer coefficient (Keff) is examined and compared. One such set of models exhibit power-law (fractal) characteristics, and the variability of dispersion and Keff with scale is in good agreement with analytical expressions described in the literature. This work offers an insight into the impacts of heterogeneity on the scaling of effective transport parameters. A key finding is that spatial heterogeneity models with similar univariate and bivariate statistics may exhibit different scaling characteristics because of the influence of higher order statistics. More mixing is observed in the channelized models with higher-order continuity. It

  6. Direct Measurements of Gas/Particle Partitioning and Mass Accommodation Coefficients in Environmental Chambers.

    Krechmer, Jordan E; Day, Douglas A; Ziemann, Paul J; Jimenez, Jose L

    2017-10-17

    Secondary organic aerosols (SOA) are a major contributor to fine particulate mass and wield substantial influences on the Earth's climate and human health. Despite extensive research in recent years, many of the fundamental processes of SOA formation and evolution remain poorly understood. Most atmospheric aerosol models use gas/particle equilibrium partitioning theory as a default treatment of gas-aerosol transfer, despite questions about potentially large kinetic effects. We have conducted fundamental SOA formation experiments in a Teflon environmental chamber using a novel method. A simple chemical system produces a very fast burst of low-volatility gas-phase products, which are competitively taken up by liquid organic seed particles and Teflon chamber walls. Clear changes in the species time evolution with differing amounts of seed allow us to quantify the particle uptake processes. We reproduce gas- and aerosol-phase observations using a kinetic box model, from which we quantify the aerosol mass accommodation coefficient (α) as 0.7 on average, with values near unity especially for low volatility species. α appears to decrease as volatility increases. α has historically been a very difficult parameter to measure with reported values varying over 3 orders of magnitude. We use the experimentally constrained model to evaluate the correction factor (Φ) needed for chamber SOA mass yields due to losses of vapors to walls as a function of species volatility and particle condensational sink. Φ ranges from 1-4.

  7. Computation of the mass attenuation coefficient of polymeric materials at specific gamma photon energies

    Mirji, Rajeshwari; Lobo, Blaise

    2017-06-01

    The gamma ray mass attenuation coefficients of ten synthetic polymeric materials, namely, polyethylene (PE), polystyrene (PS), polycarbonate (PC), polyvinyl alcohol (PVA), polyvinyl chloride (PVC), Polyethylene terephthalate (PET), Polyvinyl pyrrolidone (PVP), Polytetrafluoroethylene (PTFE), Polypropylene (PP) and Polymethyl methacrylate (PMMA) have been calculated using second order polynomial equation and logarithmic interpolation formula at selected gamma photon energies, in the energy range starting from 14.4 keV up to 1332 keV. It is important to note that second order polynomial equation fits very well with NIST data for all the polymeric materials considered here, for gamma photon energies ranging from 300 keV up to 2000 keV. Third order polynomial fitting is best suited for lower gamma photon energies (from 10 keV up to 200 keV).

  8. Affection of blood supply of focal hepatic mass on apparent diffusion coefficient of the lesions

    Chen Zaizhi; Wu Yulin; Xu Zhongfei; Yang Zhenghan; Chen Min; Zhou Cheng; Xie Jingxia

    2002-01-01

    Objective: To investigate the affection of lesion blood supply on apparent diffusion coefficient (ADC) of focal hepatic mass. Methods: Diffusion-weighted imaging (DWI) with different b values was performed in 87 patients with 159 focal hepatic lesions. ADCs of lesion, liver, spleen, gallbladder were measured in every case. Results: On DWI with small b value and small b value remainder, ADCs were affected by blood perfusion of tissues or lesions. The mean ADC of hypervascular lesions was significantly higher than that of hypovascular lesions on DWI with small b value, and hemoangiomas got the highest mean ADC. The mean ADC of hepatic cysts was not affected by b value. Conclusion: Blood perfusion affects ADC of tissue or focal hepatic lesion, particularly on DWI with small b value, and to some degree, DWI and ADC can reflect the blood supply of focal hepatic lesion

  9. Simultaneous determination of mass and thermal accommodation coefficients from temporal evolution of an evaporating water microdroplet

    Zientara, M; Jakubczyk, D; Derkachov, G; Kolwas, K; Kolwas, M

    2005-01-01

    Scattering of coherent light by an evaporating droplet of pure water several micrometres in size was investigated. The droplet was levitated in an electrodynamic trap placed in a small climatic chamber. The evolution of the droplet radius and the evolution dynamics were investigated by means of analysing the scattering patterns with the aid of Mie theory. A numerical model of droplet evolution, incorporating the kinetic effects near the droplet surface, was constructed. Application of this model to the experimental data allowed us to determine the mass and thermal accommodation coefficients to be α C = 0.12 ± 0.02 and α T = 0.65 ± 0.09, respectively. This model enabled us to determine with high precision the temperature evolution of the droplet and the relative humidity in the droplet vicinity

  10. Thermodiffusion Coefficient Analysis of n-Dodecane /n-Hexane Mixture at Different Mass Fractions and Pressure Conditions

    Lizarraga, Ion; Bou-Ali, M. Mounir; Santamaría, C.

    2018-03-01

    In this study, the thermodiffusion coefficient of n-dodecane/n-hexane binary mixture at 25 ∘C mean temperature was determined for several pressure conditions and mass fractions. The experimental technique used to determine the thermodiffusion coefficient was the thermograviational column of cylindrical configuration. In turn, thermophysical properties, such as density, thermal expansion, mass expansion and dynamic viscosity up to 10 MPa were also determined. The results obtained in this work showed a linear relation between the thermophysical properties and the pressure. Thermodiffusion coefficient values confirm a linear effect when the pressure increases. Additionally, a new correlation based on the thermodiffusion coefficient for n C12/n C6 binary mixture at 25 ∘C temperature for any mass fraction and pressures, which reproduces the data within the experimental error, was proposed.

  11. Mass-transport limitation to in-cloud reaction rates: Implications of new accommodation coefficient measurements

    Schwartz, S.E.

    1988-10-01

    Although it has been recognized for some time that the rate of reactive uptake of gases in cloudwater can depend on the value of the mass-accommodation coefficient (α) describing interfacial mass transport (MT), definitive evaluation of such rates is only now becoming possible with the availability of measurements of α for gases of atmospheric interest at air-water interfaces. Examination of MT limitation to the rate of in-cloud aqueous-phase oxidation of SO 2 by O 3 and H 2 O 2 shows that despite the low value of α/sub O3/ (5 /times/ 10/sup /minus/4/), interfacial MT of this species is not limiting under essentially all conditions of interest; the high values of α for SO 2 (≥ 0.2) and H 2 O 2 (≥ 0.08) indicate no interfacial MT limitation for these species also. Although gas- and aqueous-phase MT can be limiting under certain extremes of conditions, treating the system as under chemical kinetic control is generally an excellent approximation. Interfacial MT limitation also is found not to hinder the rate of H 2 O 2 formation by aqueous-phase disproportionation of HO 2 . Finally, the rapid uptake of N 2 O 5 by cloud droplets implies that the yield of aqueous HNO 3 from in-cloud gas-phase oxidation of NO 2 by O 3 can be substantial even under daytime conditions. This report consists of copies of viewgraphs prepared for this presentation

  12. Absorption and scattering coefficients estimation in two-dimensional participating media using the generalized maximum entropy and Levenberg-Marquardt methods

    Berrocal T, Mariella J.; Roberty, Nilson C.; Silva Neto, Antonio J.; Universidade Federal, Rio de Janeiro, RJ

    2002-01-01

    The solution of inverse problems in participating media where there is emission, absorption and dispersion of the radiation possesses several applications in engineering and medicine. The objective of this work is to estimative the coefficients of absorption and dispersion in two-dimensional heterogeneous participating media, using in independent form the Generalized Maximum Entropy and Levenberg Marquardt methods. Both methods are based on the solution of the direct problem that is modeled by the Boltzmann equation in cartesian geometry. Some cases testes are presented. (author)

  13. Study of the influence of surfactants on the activity coefficients and mass transfer coefficients of methanol in aqueous mixtures by reversed-flow gas chromatography.

    Kotsalos, Efthimios; Brezovska, Boryana; Sevastos, Dimitrios; Vagena, Artemis; Koliadima, Athanasia; Kapolos, John; Karaiskakis, George

    2017-11-17

    This work focuses on the influences of surfactants on the activity coefficients, γ, of methanol in binary mixtures with water, as well as on the mass transfer coefficients, k c , for the evaporation of methanol, which is a ubiquitous component in the troposphere, from mixtures of methanol with water at various surfactant's and methanol's concentrations. The technique used is the Reversed-Flow Gas Chromatography (R.F.G.C.), a version of Inverse Gas Chromatography, which allows determining both parameters by performing only one experiment for the k c parameter and two experiments for the γ parameter. The k c and γ values decrease in the presence of the three surfactants used (CTAB, SDS, TRITON X-100) at all methanol's and surfactant's concentrations. The decrease in the methanol's molar fraction, at constant number of surfactant films leads to a decrease in the k c and γ values, while the decrease in the surfactant's concentration, at constant methanol's molar fraction leads to an increase in both the k c and γ parameters. Mass transfer coefficients for the evaporation of methanol at the surfactant films, are also calculated which are approximately between 4 and 5 orders of magnitude larger than the corresponding mass transfer coefficients at the liquid films. Finally, thicknesses of the boundary layer of methanol in the mixtures of methanol with water were determined. The quantities found are compared with those given in the literature or calculated theoretically using various empirical equations. The precision of the R.F.G.C. method for measuring γ and k c parameters is approximately high (94.3-98.0%), showing that R.F.G.C. can be used with success not only for the thermodynamic study of solutions, but also for the interphase transport. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Comparison Study on Empirical Correlation for Mass Transfer Coefficient with Gas Hold-up and Input Power of Aeration Process

    Park, Sang Kyoo; Yang, Hei Cheon

    2017-01-01

    As stricter environmental regulation have led to an increase in the water treatment cost, it is necessary to quantitatively study the input power of the aeration process to improve the energy efficiency of the water treatment processes. The objective of this study is to propose the empirical correlations for the mass transfer coefficient with the gas hold-up and input power in order to investigate the mass transfer characteristics of the aeration process. It was found that as the input power increases, the mass transfer coefficient increases because of the decrease of gas hold-up and increase of Reynolds number, the penetration length, and dispersion of mixed flow. The correlations for the volumetric mass transfer coefficients with gas hold-up and input power were consistent with the experimental data, with the maximum deviation less than approximately ±10.0%.

  15. Comparison Study on Empirical Correlation for Mass Transfer Coefficient with Gas Hold-up and Input Power of Aeration Process

    Park, Sang Kyoo; Yang, Hei Cheon [Chonnam Nat’l Univ., Gwangju (Korea, Republic of)

    2017-06-15

    As stricter environmental regulation have led to an increase in the water treatment cost, it is necessary to quantitatively study the input power of the aeration process to improve the energy efficiency of the water treatment processes. The objective of this study is to propose the empirical correlations for the mass transfer coefficient with the gas hold-up and input power in order to investigate the mass transfer characteristics of the aeration process. It was found that as the input power increases, the mass transfer coefficient increases because of the decrease of gas hold-up and increase of Reynolds number, the penetration length, and dispersion of mixed flow. The correlations for the volumetric mass transfer coefficients with gas hold-up and input power were consistent with the experimental data, with the maximum deviation less than approximately ±10.0%.

  16. Reduction in biomass burning aerosol light absorption upon humidification: Roles of inorganically-induced hygroscopicity, particle collapse, and photoacoustic heat and mass transfer

    lewis, Kristen A.; Arnott, W. P.; Moosmuller, H.; Chakrabarti, Raj; Carrico, Christian M.; Kreidenweis, Sonia M.; Day, Derek E.; Malm, William C.; Laskin, Alexander; Jimenez, Jose L.; Ulbrich, Ingrid M.; Huffman, John A.; Onasch, Timothy B.; Trimborn, Achim; Liu, Li; Mishchenko, M.

    2009-11-27

    Smoke particle emissions from the combustion of biomass fuels typical for the western and southeastern United States were studied and compared under high humidity and ambient conditions in the laboratory. The fuels used are Montana ponderosa pine (Pinus ponderosa), southern California chamise (Adenostoma fasciculatum), and Florida saw palmetto (Serenoa repens). Information on the non-refractory chemical composition of biomass burning aerosol from each fuel was obtained with an aerosol mass spectrometer and through estimation of the black carbon concentration from light absorption measurements at 870 nm. Changes in the optical and physical particle properties under high humidity conditions were observed for hygroscopic smoke particles containing substantial inorganic mass fractions that were emitted from combustion of chamise and palmetto fuels. Light scattering cross sections increased under high humidity for these particles, consistent with the hygroscopic growth measured for 100 nm particles in HTDMA measurements. Photoacoustic measurements of aerosol light absorption coefficients reveal a 20% reduction with increasing relative humidity, contrary to the expectation of light absorption enhancement by the liquid coating taken up by hygroscopic particles. This reduction is hypothesized to arise from two mechanisms: 1. Shielding of inner monomers after particle consolidation or collapse with water uptake; 2. The contribution of mass transfer through evaporation and condensation at high relative humidity to the usual heat transfer pathway for energy release by laser heated particles in the photoacoustic measurement of aerosol light absorption. The mass transfer contribution is used to evaluate the fraction of aerosol surface covered with liquid water solution as a function of RH.

  17. Water absorption lines, 931-961 nm - Selected intensities, N2-collision-broadening coefficients, self-broadening coefficients, and pressure shifts in air

    Giver, L. P.; Gentry, B.; Schwemmer, G.; Wilkerson, T. D.

    1982-01-01

    Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.

  18. Absorption coefficient and refractive index changes of a quantum ring in the presence of spin-orbit couplings: Temperature and Zeeman effects

    Zamani, A.; Azargoshasb, T.; Niknam, E.

    2017-10-01

    Effects of applied magnetic field, temperature and dimensions on the optical absorption coefficients (AC) and refractive index (RI) changes of a GaAs quantum ring are investigated in the presence of both Rashba and Dresselhaus spin-orbit interactions (SOI). To this end, the finite difference method (FDM) is used in order to numerically calculate the energy eigenvalues and eigenstates of the system while the compact density matrix approach is hired to calculate the optical properties. It is shown that application of magnetic field, temperature as well as the geometrical size in the presence of spin-orbit interactions, alter the electronic structure and consequently influence the linear and third-order nonlinear optical absorption coefficients as well as the refractive index changes of the system. Results show an obvious blue shift in optical curves with enhancing external magnetic field and temperature while the increment of dimensions result in red shift.

  19. Evaluation of self-absorption coefficients of aluminum emission lines in laser-induced breakdown spectroscopy measurements

    El Sherbini, A.M.; El Sherbini, Th.M.; Hegazy, H.; Cristoforetti, G.; Legnaioli, S.; Palleschi, V.; Pardini, L.; Salvetti, A.; Tognoni, E.

    2005-01-01

    In quantitative Laser Induced Breakdown Spectroscopy (LIBS) measurements it is essential to account for the effect of self-absorption on the emission lines intensity. In order to quantify this effect, in this paper we propose a simple method for evaluating the ratio between the actual measured line intensity and the intensity expected in absence of self-absorption and, if necessary, correcting the effect of self-absorption on line intensity. The method, based on a homogeneous plasma model, is applicable when the plasma electron density is known and in particular to lines whose Stark broadening parameter is available

  20. A new term 'Jzeff' derived from measured total attenuation coefficients of photons near the absorption edges of some compounds

    Polat, Recep; Icelli, Orhan

    2010-01-01

    In order to determine the effect of XAFS (X-ray absorption fine structure) on J zeff , we have measured μ/ρ values of compounds, which are determined by the mixture rule or the independent atomic model. Also, we want to obtain both XAFS effect and non-applicability or applicability of mixture rule. The most crucial finding in this study is that measurement of the effective atomic number is not appropriate near the absorption edge and the effective atomic number is affected by near the absorption edge. The results obtained have been compared with theoretical values. Also, the objective of this study is to show that there is a term 'J zeff ' between effective atomic numbers and absorption jump factor.

  1. Determination of Coefficient of Thermal Expansion (CTE) of 20MPa Mass Concrete Using Granite Aggregate

    Chee Siang, GO

    2017-07-01

    Experimental test was carried out to determine the coefficient of thermal expansion (CTE) value of 20MPa mass concrete using granite aggregate. The CTE value was established using procedure proposed by Kada et al. 2002 in determining the magnitude of early-ages CTE through laboratory test which is a rather accurate way by eliminating any possible superimposed effect of others early-age thermal deformation shrinkages such as autogenous, carbonation, plastic and drying shrinkage. This was done by submitting granite concrete block samples instrumented with ST4 vibrating wire extensometers to thermal shocks. The response of the concrete samples to this shock results in a nearly instantaneous deformation, which are measured by the sensor. These deformations, as well as the temperature signal, are used to calculate the CTE. By repeating heat cycles, the variation in the early-ages of concrete CTE over time was monitored and assessed for a period of upto 7 days. The developed CTE value facilitating the verification and validation of actual maximum permissible critical temperature differential limit (rather than arbitrarily follow published value) of cracking potential. For thick sections, internal restraint is dominant and this is governed by differentials mainly. Of the required physical properties for thermal modelling, CTE is of paramount importance that with given appropriate internal restraint factor the condition of cracking due to internal restraint is governs by equation, ΔTmax= 3.663ɛctu / αc. Thus, it can be appreciated that an increase in CTE will lower the maximum allowable differential for cracking avoidance in mass concrete while an increase of tensile strain capacity will increase the maximum allowable temperature differential.

  2. Measurement of the x-ray mass-attenuation coefficients of gold, derived quantities between 14 keV and 21 keV and determination of the bond lengths of gold

    Glover, J L; Chantler, C T; Barnea, Z; Rae, N A; Tran, C Q

    2010-01-01

    The x-ray mass-attenuation coefficients of gold are measured at 91 energies between 14 keV and 21 keV using synchrotron radiation. The measurements are accurate to between 0.08% and 0.1%. The photoelectric mass-absorption coefficients and the imaginary component of the form factors of gold are also determined. The results include the L I edge and are the most accurate and extensive gold dataset available in this energy range. An analysis of the L I edge XAFS showed excellent agreement between the measured and simulated XAFS and yielded highly accurate values of the bond lengths of gold. When our results are compared with earlier measurements and with predictions of major theoretical tabulations, significant discrepancies are noted. The comparison raises questions about the nature of discrepancies between experimental and theoretical values of mass-attenuation coefficients.

  3. Study on aroma components of osmanthus by absorption wire gas chromatography/mass spectrometry

    Feng Janyue; Zhao Jing; Huang Qiaoqiao; Feng Lianmei

    2001-01-01

    The aroma components of fresh osmanthus are captured by absorption wires. The fragrant components absorbed in the wires are desorbed immediately at 358 degree C in Curie-point pyrolyzed, and then led into GC/MS to analyze. As a result, 41 aroma compounds such as β-linalool, linalooloxide, β-ocimene etc. in osmanthus are detected qualitatively by gas chromatography/mass spectrometry. This method can be used to analyze the change of aroma compounds of fresh flowers while blossoming

  4. Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling

    Chang, Leyen S.; Strand, Christopher L.; Jeffries, Jay B.; Hanson, Ronald K.; Diskin, Glenn S.; Gaffney, Richard L.; Capriotti, Diego P.

    2011-01-01

    Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.

  5. Radiation dose estimation and mass attenuation coefficients of cement samples used in Turkey

    Damla, N.; Cevik, U.; Kobya, A.I.; Celik, A.; Celik, N.; Van Grieken, R.

    2010-01-01

    Different cement samples commonly used in building construction in Turkey have been analyzed for natural radioactivity using gamma-ray spectrometry. The mean activity concentrations observed in the cement samples were 52, 40 and 324 Bq kg -1 for 226 Ra, 232 Th and 40 K, respectively. The measured activity concentrations for these radionuclides were compared with the reported data of other countries and world average limits. The radiological hazard parameters such as radium equivalent activities (Ra eq ), gamma index (I γ ) and alpha index (I α ) indices as well as terrestrial absorbed dose and annual effective dose rate were calculated and compared with the international data. The Ra eq values of cement are lower than the limit of 370 Bq kg -1 , equivalent to a gamma dose of 1.5 mSv y -1 . Moreover, the mass attenuation coefficients were determined experimentally and calculated theoretically using XCOM in some cement samples. Also, chemical compositions analyses of the cement samples were investigated.

  6. Radiation dose estimation and mass attenuation coefficients of marble used in Turkey

    Cevik, U.; Damla, N.; Kobya, A.I.; Celik, A.; Kara, A.

    2010-01-01

    In this study the natural radioactivity in marble samples used in Turkey was measured by means of gamma spectrometry. The results showed that the specific activities of 226 Ra, 232 Th and 40 K ranged from 10 to 92 Bq kg -1 , from 4 to 122 Bq kg -1 and from 28 to 676 Bq kg -1 , respectively. The radiological hazards in marble samples due to the natural radioactivity were inferred from calculations of radium equivalent activities (Ra eq ), indoor absorbed dose rate in air values, the annual effective dose and gamma and alpha indexes. These radiological parameters were evaluated and compared with the internationally recommended values. The measurements showed that marble samples used in Turkey have low level of natural radioactivity; therefore, the use of these types of marble in dwellings is safe for inhabitants. Mass attenuation coefficients (μ/ρ) were obtained both experimentally and theoretically for different marble samples produced in Turkey by using gamma-ray transmission method. Experimental values showed a good agreement with the theoretical values.

  7. Transfer coefficients of energy in mass for X radiation-air: the kV relation and effective energy

    Teixeira, G.J.; Sousa, C.H.S.; Peixoto, J.G.P.

    2014-01-01

    The objective was to determine, through specific software, the mass-energy transfer coefficients by X-ray beams in air between 30-150 kV. Were generated by the Spectrum Processor program, the spectra and calculated their mass coefficients. The results behaved numerically decreasing order, ranging between 0.3733 and 0.0439 cm 2 /g, inversely proportional to the voltage used and differing behavior of mono-energetic beams above 100 keV. Values align with literal definitions of the interaction of radiation with matter, being useful for dosimetry in diagnostic radiology, including for systems not using an ionization chamber. (author)

  8. Long term change in atmospheric dust absorption, dust scattering and black carbon aerosols scattering coefficient parameters over western Indian locations

    Satoliya, Anil Kumar; Vyas, B. M.; Shekhawat, M. S.

    2018-05-01

    The first time satellite space based measurement of atmospheric black carbon (BC) aerosols scattering coefficient at 550nm (BC SC at 550nm), dust aerosols scattering and dust aerosols extinction coefficient (DSC at 550nm and DEC at 550nm) parameters have been used to understand their long term trend of natural and anthropogenic aerosols behavior with its close association with ground based measured precipitation parameters such as Total Rain Fall (TRF), and Total Number of Rainy Days (TNRD) for the same period over western Indian regions concerned to the primary aerosols sources of natural activities. The basic objective of this study is an attempt to investigate the inter-correlation between dust and black carbon aerosols loading characteristics with a variation of rainfall pattern parameters as indirect aerosols induced effect i.e., aerosols-cloud interaction. The black carbon aerosols generated by diverse anthropogenic or human made activities are studied by choosing of measured atmospheric BC SC at 550nm parameter, whereas desert dust mineral aerosols primarily produced by varieties of natural activities pre-dominated of dust mineral desert aerosols mainly over Thar desert influenced area of hot climate and rural tropical site are investigated by selecting DSC at 550nm and DEC at 550nm of first semi-urban site i.e., Udaipur (UDP, 24.6°N, 73.35°E, 580m above surface level (asl)) situated in southern Rajasthan part as well as over other two Great Indian Thar desert locations i.e., Jaisalmer (JSM, 26.90°N, 69.90°E, 220m asl)) and Bikaner (BKN, 28.03°N, 73.30°E, 224m asl) located in the vicinity of the Thar desert region situated in Rajasthan state of the western Indian region. The source of the present study would be collection of longer period of monthly values of the above parameters of spanning 35 years i.e., 1980 to 2015. Such types of atmospheric aerosols-cloud monsoon interaction investigation is helpful in view of understanding their direct and

  9. Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the 13.5-41.5-keV energy range

    Jonge, Martin D. de; Tran, Chanh Q.; Chantler, Christopher T.; Barnea, Zwi; Dhal, Bipin B.; Cookson, David J.; Lee, Wah-Keat; Mashayekhi, Ali

    2005-01-01

    We use the x-ray extended-range technique (XERT) [Chantler et al., Phys. Rev. A 64, 062506 (2001)] to measure the mass attenuation coefficients of molybdenum in the x-ray energy range of 13.5-41.5 keV to 0.02-0.15 % accuracy. Measurements made over an extended range of the measurement parameter space are critically examined to identify, quantify, and correct where necessary a number of experimental systematic errors. These results represent the most extensive experimental data set for molybdenum and include absolute mass attenuation coefficients in the regions of the x-ray absorption fine structure (XAFS) and x-ray-absorption near-edge structure (XANES). The imaginary component of the atomic form-factor f 2 is derived from the photoelectric absorption after subtracting calculated Rayleigh and Compton scattering cross sections from the total attenuation. Comparison of the result with tabulations of calculated photoelectric absorption coefficients indicates that differences of 1-15 % persist between the calculated and observed values

  10. Effect of mass of neptunium V in intestinal absorption in the monkey and the rat

    Metivier, H.; Masse, R.; Lafuma, J.

    1983-01-01

    The coefficient of gastrointestinal transfer of neptunium as pentavalent neptunyl nitrate was studied in rats and monkeys as a function of the ingested mass. In both species, the transfer coefficient ranged between 1.10 - 3 - 1.10 - 2 when the administered mass varied from 0.3 ng to 2 mg per kg. At low concentrations, the values obtained in the monkey are about twice as low as thoses obtained in the rat. Considering the strong urinary excretion, the amounts retained at the organ levels represent about 0.1% in the rat and 0.04% in the monkey for low concentrations. The values obtained are usually in good agreement with the few data published on the rat [fr

  11. Halo mass dependence of H I and O VI absorption: evidence for differential kinematics

    Mathes, Nigel L.; Churchill, Christopher W.; Nielsen, Nikole M.; Trujillo-Gomez, Sebastian [New Mexico State University, Las Cruces, NM 88003 (United States); Kacprzak, Glenn G. [Swinburne University of Technology, Victoria 3122 (Australia); Charlton, Jane; Muzahid, Sowgat [The Pennsylvania State University, University Park, PA 16802 (United States)

    2014-09-10

    We studied a sample of 14 galaxies (0.1 < z < 0.7) using HST/WFPC2 imaging and high-resolution HST/COS or HST/STIS quasar spectroscopy of Lyα, Lyβ, and O VI λλ1031, 1037 absorption. The galaxies, having 10.8 ≤ log (M {sub h}/M {sub ☉}) ≤ 12.2, lie within D = 300 kpc of quasar sightlines, probing out to D/R {sub vir} = 3. When the full range of M {sub h} and D/R {sub vir} of the sample are examined, ∼40% of the H I absorbing clouds can be inferred to be escaping their host halo. The fraction of bound clouds decreases as D/R {sub vir} increases such that the escaping fraction is ∼15% for D/R {sub vir} < 1, ∼45% for 1 ≤ D/R {sub vir} < 2, and ∼90% for 2 ≤ D/R {sub vir} < 3. Adopting the median mass log M {sub h}/M {sub ☉} = 11.5 to divide the sample into 'higher' and 'lower' mass galaxies, we find a mass dependency for the hot circumgalactic medium kinematics. To our survey limits, O VI absorption is found in only ∼40% of the H I clouds in and around lower mass halos as compared to ∼85% around higher mass halos. For D/R {sub vir} < 1, lower mass halos have an escape fraction of ∼65%, whereas higher mass halos have an escape fraction of ∼5%. For 1 ≤ D/R {sub vir} < 2, the escape fractions are ∼55% and ∼35% for lower mass and higher mass halos, respectively. For 2 ≤ D/R {sub vir} < 3, the escape fraction for lower mass halos is ∼90%. We show that it is highly likely that the absorbing clouds reside within 4R {sub vir} of their host galaxies and that the kinematics are dominated by outflows. Our finding of 'differential kinematics' is consistent with the scenario of 'differential wind recycling' proposed by Oppenheimer et al. We discuss the implications for galaxy evolution, the stellar to halo mass function, and the mass-metallicity relationship of galaxies.

  12. Remarkable optical red shift and extremely high optical absorption coefficient of V-Ga co-doped TiO2

    Deng, Quanrong; Han, Xiaoping; Gao, Yun; Shao, Guosheng

    2012-07-01

    A first attempt has been made to study the effect of codoping of transition metal and sp metal on the electronic structure and associated optical properties of TiO2, through V-Ga codoped thin films. V-Ga codoped rutile TiO2 films were fabricated on fused quartz substrates using pulsed laser ablation, followed by heat treatment at high temperatures. Gigantic redshift in the optical absorption edge was observed in V-Ga co-doped TiO2 materials, from UV to infrared region with high absorption coefficient. Through combined structural characterization and theoretical modeling, this is attributed to the p-d hybridization between the two metals. This leads to additional energy bands to overlap with the minimum of the conduction band, leading to remarkably narrowed band gap free of mid-gap states. The direct-gap of the co-doped phase is key to the remarkably high optical absorption coefficient of the coped titania.

  13. Obtaining the mass attenuation coefficient of the wood to a beam of gamma-ray of 241Am

    Costa, Vladimir Eliodoro; Rezende, Marcos Antonio de

    2009-01-01

    Full text: The quality of wood produced in Brazil reforestation has been the subject of many discussions in the Forestry Sector. SeEKXing to produce a rapid growth and wood quality, the Forestry Sector, found in Applied Nuclear Physics, a precise method of determining the density of wood known as ad hoc technique of attenuation of gamma-ray. The radioisotope used in this technique is that it has a picture 241 Am peak of 59.6 keV gamma-ray. This work has the objective of determining the mass attenuation coefficient of wood of the genus Eucalyptus for 241 Am radioisotope. We used 324 samples of wood from six different treatments: a seminal of Eucalyptus grandis; two clones of E. grandis; three clones of the hybrid E. grandis x E. urophylla. The same assay was used for the six treatments. It was determined the basic density of the samples by the method of immersion in water and then the basic density was converted into apparent density in the moisture equilibrium and it was determined the attenuation coefficient of mass. Preliminary results showed that the attenuation coefficient of mass did not vary between treatments, and its average value 0.1822 ± 0.0015. It was to here that the attenuation coefficient of mass in the wood of the genus Eucalyptus in moisture equilibrium can be constant. (author)

  14. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Conti, C. C.; Anjos, M. J.; Salgado, C. M.

    2014-09-01

    X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br.

  15. Determination of mass attenuation coefficient in wood and leaves of typical trees by gamma-ray attenuation technique

    Miranda, Regina M. de; Pascholati, Elisabete M.

    1997-01-01

    Using an 241 Am source the mass attenuation coefficient of different woods and leaves of typical species of the Atlantic Forest were measured. The results for natural wood, dry wood and dry leaves indicate that the variation is very small among different species. However, woods present a higher attenuation than leaves, both depending on their water content. (author). 10 refs., 3 figs., 1 tab

  16. Differential optical absorption spectroscopy (DOAS and air mass factor concept for a multiply scattering vertically inhomogeneous medium: theoretical consideration

    V. V. Rozanov

    2010-06-01

    Full Text Available The Differential Optical Absorption Spectroscopy (DOAS technique is widely used to retrieve amounts of atmospheric species from measurements of the direct solar light transmitted through the Earth's atmosphere as well as of the solar light scattered in the atmosphere or reflected from the Earth's surface. For the transmitted direct solar light the theoretical basis of the DOAS technique represented by the Beer-Lambert law is well studied. In contrast, scarcely investigated is the theoretical basis and validity range of the DOAS method for those cases where the contribution of the multiple scattering processes is not negligible. Our study is intended to fill this gap by means of a theoretical investigation of the applicability of the DOAS technique for the retrieval of amounts of atmospheric species from observations of the scattered solar light with a non-negligible contribution of the multiple scattering.

    Starting from the expansion of the intensity logarithm in the functional Taylor series we formulate the general form of the DOAS equation. The thereby introduced variational derivative of the intensity logarithm with respect to the variation of the gaseous absorption coefficient, which is often referred to as the weighting function, is demonstrated to be closely related to the air mass factor. Employing some approximations we show that the general DOAS equation can be rewritten in the form of the weighting function (WFDOAS, the modified (MDOAS, and the standard DOAS equations. For each of these forms a specific equation for the air mass factor follows which, in general, is not suitable for other forms of the DOAS equation. Furthermore, the validity range of the standard DOAS equation is quantitatively investigated using a suggested criterion of a weak absorption.

    The results presented in this study are intended to provide a basis for a better understanding of the applicability range of different forms of the DOAS equation as

  17. Influence of high range of mass transfer coefficient and convection heat transfer on direct contact membrane distillation performance

    Lee, Jung Gil

    2017-11-03

    In order to improve water production of membrane distillation (MD), the development of high performance membrane having better mass transfer and enhancement of convection heat transfer in MD module have been continuously investigated. This paper presents the relationship between the heat and mass transfer resistance across the membrane and the performance improvement. Various ranges of mass transfer coefficient (MTC) from normal (0.3×10−6 to 2.1×10−6kg/m2sPa: currently available membranes) to high (>2.1×10−6kg/m2sPa: membranes under development) were simulated using an experimentally validated model at different ranges of convection heat transfer by varying the inlet flow rates and spacer enhancement factor. The effect of mass transfer and convection heat transfer on the MD performance parameters including temperature polarization coefficient (TPC), mean permeate flux, and specific energy consumption were investigated in a direct contact MD (DCMD) configuration. Results showed that improving the MTC at the low ranges is more important than that at the high ranges where the heat transfer resistance becomes dominant and hence the convection heat transfer coefficient must be increased. Therefore, an effort on designing MD modules using feed and permeate spacers and controlling the membrane surface roughness to increase the convection heat transfer and TPC in the channel aiming to enhance the flux is required because the currently developed mass transfer has almost reached the critical point.

  18. Linear and nonlinear optical absorption coefficients and refractive index changes in GaN/Al{sub x}Ga{sub (1−x)}N double quantum wells operating at 1.55 μm

    Dakhlaoui, Hassen [Department of Physics, College of Science for Girls, University of Dammam (UOD), Saudi Arabia and Department of Physics, Faculty of Sciences of Bizerte, University of Carthage (Tunisia)

    2015-04-07

    In the present paper, the linear and nonlinear optical absorption coefficients and refractive index changes between the ground and the first excited states in double GaN/Al{sub x}Ga{sub (1−x)}N quantum wells are studied theoretically. The electronic energy levels and their corresponding wave functions are obtained by solving Schrödinger-Poisson equations self-consistently within the effective mass approximation. The obtained results show that the optical absorption coefficients and refractive index changes can be red- and blue-shifted through varying the left quantum well width and the aluminum concentration x{sub b2} of the central barrier, respectively. These structural parameters are found to present optimum values for carrying out the transition of 0.8 eV (1.55 μm). Furthermore, we show that the desired transition can also be achieved by replacing the GaN in the left quantum well with Al{sub y}Ga{sub (1−y)}N and by varying the aluminum concentration y{sub Al}. The obtained results give a new degree of freedom in optoelectronic device applications such as optical fiber telecommunications operating at (1.55 μm)

  19. A Multi-Band Analytical Algorithm for Deriving Absorption and Backscattering Coefficients from Remote-Sensing Reflectance of Optically Deep Waters

    Lee, Zhong-Ping; Carder, Kendall L.

    2001-01-01

    A multi-band analytical (MBA) algorithm is developed to retrieve absorption and backscattering coefficients for optically deep waters, which can be applied to data from past and current satellite sensors, as well as data from hyperspectral sensors. This MBA algorithm applies a remote-sensing reflectance model derived from the Radiative Transfer Equation, and values of absorption and backscattering coefficients are analytically calculated from values of remote-sensing reflectance. There are only limited empirical relationships involved in the algorithm, which implies that this MBA algorithm could be applied to a wide dynamic range of waters. Applying the algorithm to a simulated non-"Case 1" data set, which has no relation to the development of the algorithm, the percentage error for the total absorption coefficient at 440 nm a (sub 440) is approximately 12% for a range of 0.012 - 2.1 per meter (approximately 6% for a (sub 440) less than approximately 0.3 per meter), while a traditional band-ratio approach returns a percentage error of approximately 30%. Applying it to a field data set ranging from 0.025 to 2.0 per meter, the result for a (sub 440) is very close to that using a full spectrum optimization technique (9.6% difference). Compared to the optimization approach, the MBA algorithm cuts the computation time dramatically with only a small sacrifice in accuracy, making it suitable for processing large data sets such as satellite images. Significant improvements over empirical algorithms have also been achieved in retrieving the optical properties of optically deep waters.

  20. Donor impurity-related linear and nonlinear optical absorption coefficients in GaAs/Ga{sub 1−x}Al{sub x}As concentric double quantum rings: Effects of geometry, hydrostatic pressure, and aluminum concentration

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Restrepo, R.L. [Física Teórica y Aplicada, Escuela de Ingeniería de Antioquia, AA 7516, Medellín (Colombia); Grupo de Materia Condensada-UdeA, Instituto de Física, Facultadde Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21,Medellín (Colombia); Mora-Ramos, M.E. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultadde Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21,Medellín (Colombia); Facultad de Ciencias, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Duque, C.A., E-mail: cduque@fisica.udea.edu.co [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultadde Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21,Medellín (Colombia)

    2014-01-15

    The linear and nonlinear optical absorption associated with the transition between 1s and 2s states corresponding to the electron-donor-impurity complex in GaAs/Ga{sub 1−x}Al{sub x}As three-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and the variation of the aluminum concentration, the energies of the ground and first excited s-like states of a donor impurity in such a system have been calculated using the effective mass approximation and a variational method. The energies of these states and the corresponding threshold energy of the optical transitions are examined as functions of hydrostatic pressure, aluminum concentration, radial impurity position, as well as the geometrical dimensions of the structure. The dependencies of the linear, nonlinear and total optical absorption coefficients as functions of the incident photon energy are investigated for different values of those mentioned parameters. It is found that the influences mentioned above lead to either redshifts or blueshifts of the resonant peaks of the optical absorption spectrum. It is particularly discussed the unusual property exhibited by the third-order nonlinear of becoming positive for photon energies below the resonant transition one. It is shown that this phenomenon is associated with the particular features of the system under study, which determine the values of the electric dipole moment matrix elements. -- Highlights: • Intra-band optical absorption associated to impurity states in double quantum rings. • Combined effects of hydrostatic pressure and aluminum concentration are studied. • The influences mentioned above lead to shifts of resonant peaks. • It is discussed an unusual property exhibited by the third-order nonlinear absorption.

  1. Donor impurity-related linear and nonlinear optical absorption coefficients in GaAs/Ga1−xAlxAs concentric double quantum rings: Effects of geometry, hydrostatic pressure, and aluminum concentration

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A.; Restrepo, R.L.; Mora-Ramos, M.E.; Duque, C.A.

    2014-01-01

    The linear and nonlinear optical absorption associated with the transition between 1s and 2s states corresponding to the electron-donor-impurity complex in GaAs/Ga 1−x Al x As three-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and the variation of the aluminum concentration, the energies of the ground and first excited s-like states of a donor impurity in such a system have been calculated using the effective mass approximation and a variational method. The energies of these states and the corresponding threshold energy of the optical transitions are examined as functions of hydrostatic pressure, aluminum concentration, radial impurity position, as well as the geometrical dimensions of the structure. The dependencies of the linear, nonlinear and total optical absorption coefficients as functions of the incident photon energy are investigated for different values of those mentioned parameters. It is found that the influences mentioned above lead to either redshifts or blueshifts of the resonant peaks of the optical absorption spectrum. It is particularly discussed the unusual property exhibited by the third-order nonlinear of becoming positive for photon energies below the resonant transition one. It is shown that this phenomenon is associated with the particular features of the system under study, which determine the values of the electric dipole moment matrix elements. -- Highlights: • Intra-band optical absorption associated to impurity states in double quantum rings. • Combined effects of hydrostatic pressure and aluminum concentration are studied. • The influences mentioned above lead to shifts of resonant peaks. • It is discussed an unusual property exhibited by the third-order nonlinear absorption

  2. Determination of the external mass transfer coefficient and influence of mixing intensity in moving bed biofilm reactors for wastewater treatment.

    Nogueira, Bruno L; Pérez, Julio; van Loosdrecht, Mark C M; Secchi, Argimiro R; Dezotti, Márcia; Biscaia, Evaristo C

    2015-09-01

    In moving bed biofilm reactors (MBBR), the removal of pollutants from wastewater is due to the substrate consumption by bacteria attached on suspended carriers. As a biofilm process, the substrates are transported from the bulk phase to the biofilm passing through a mass transfer resistance layer. This study proposes a methodology to determine the external mass transfer coefficient and identify the influence of the mixing intensity on the conversion process in-situ in MBBR systems. The method allows the determination of the external mass transfer coefficient in the reactor, which is a major advantage when compared to the previous methods that require mimicking hydrodynamics of the reactor in a flow chamber or in a separate vessel. The proposed methodology was evaluated in an aerobic lab-scale system operating with COD removal and nitrification. The impact of the mixing intensity on the conversion rates for ammonium and COD was tested individually. When comparing the effect of mixing intensity on the removal rates of COD and ammonium, a higher apparent external mass transfer resistance was found for ammonium. For the used aeration intensities, the external mass transfer coefficient for ammonium oxidation was ranging from 0.68 to 13.50 m d(-1) and for COD removal 2.9 to 22.4 m d(-1). The lower coefficient range for ammonium oxidation is likely related to the location of nitrifiers deeper in the biofilm. The measurement of external mass transfer rates in MBBR will help in better design and evaluation of MBBR system-based technologies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Measurement of polarization dependence of two-photon absorption coefficient in InP using extended Z-scan technique for thick materials

    Oishi, Masaki; Shinozaki, Tomohisa; Hara, Hikaru; Yamamoto, Kazunuki; Matsusue, Toshio; Bando, Hiroyuki

    2018-03-01

    The two-photon absorption coefficient β in InP has been measured in the wavelength range of 1640 to 1800 nm by the Z-scan technique in relatively thick materials. The values of β have been evaluated from the fit to the equation including the spatial and temporal profiles of the focused Gaussian beam. The polarization dependence of β has also been measured. The dependence has been expressed very well by the expression of β with the imaginary part of the third-order nonlinear susceptibility tensor χ(3).

  4. Determination of true optical absorption and scattering coefficient of wooden cell wall substance by time-of-flight near infrared spectroscopy.

    Kitamura, Ryunosuke; Inagaki, Tetsuya; Tsuchikawa, Satoru

    2016-02-22

    The true absorption coefficient (μa) and reduced scattering coefficient (μ´s) of the cell wall substance in Douglas fir were determined using time-of-flight near infrared spectroscopy. Samples were saturated with hexane, toluene or quinolone to minimize the multiple reflections of light on the boundary between pore-cell wall substance in wood. μ´s exhibited its minimum value when the wood was saturated with toluene because the refractive index of toluene is close to that of the wood cell wall substance. The optical parameters of the wood cell wall substance calculated were μa = 0.030 mm(-1) and μ´s= 18.4 mm(-1). Monte Carlo simulations using these values were in good agreement with the measured time-resolved transmittance profiles.

  5. MEASUREMENT AND CORRELATION OF THE MASS TRANSFER COEFFICIENT FOR A LIQUID-LIQUID SYSTEM WITH HIGH DENSITY DIFFERENCE

    Zhixian Huang

    Full Text Available Abstract To investigate the mass transfer behavior of a liquid-liquid system with high density difference (∆ρ≈500 kg/m3, single drop experiments were performed by using the ternary chloroform-ethanol-water system. The mass transfer direction was from the dispersed phase to the continuous phase, while the aqueous phase was dispersed in chloroform to generate drops. The influences of drop diameter, initial solute concentration and temperature on the mass transfer were investigated. The effects of the drop diameter and initial solute concentration on interfacial instability of droplets hanging in the continuous phase were also observed. For the purpose of correlation, a mass transfer enhancement factor F was introduced and then correlated as a function of dimensionless variables. The modified correlation from the mass transfer coefficient model was found to fit well with the experimental values.

  6. Dual-energy X-ray analysis using synchrotron computed tomography at 35 and 60 keV for the estimation of photon interaction coefficients describing attenuation and energy absorption.

    Midgley, Stewart; Schleich, Nanette

    2015-05-01

    A novel method for dual-energy X-ray analysis (DEXA) is tested using measurements of the X-ray linear attenuation coefficient μ. The key is a mathematical model that describes elemental cross sections using a polynomial in atomic number. The model is combined with the mixture rule to describe μ for materials, using the same polynomial coefficients. Materials are characterized by their electron density Ne and statistical moments Rk describing their distribution of elements, analogous to the concept of effective atomic number. In an experiment with materials of known density and composition, measurements of μ are written as a system of linear simultaneous equations, which is solved for the polynomial coefficients. DEXA itself involves computed tomography (CT) scans at two energies to provide a system of non-linear simultaneous equations that are solved for Ne and the fourth statistical moment R4. Results are presented for phantoms containing dilute salt solutions and for a biological specimen. The experiment identifies 1% systematic errors in the CT measurements, arising from third-harmonic radiation, and 20-30% noise, which is reduced to 3-5% by pre-processing with the median filter and careful choice of reconstruction parameters. DEXA accuracy is quantified for the phantom as the mean absolute differences for Ne and R4: 0.8% and 1.0% for soft tissue and 1.2% and 0.8% for bone-like samples, respectively. The DEXA results for the biological specimen are combined with model coefficients obtained from the tabulations to predict μ and the mass energy absorption coefficient at energies of 10 keV to 20 MeV.

  7. Seasonal variation in chromophoric dissolved organic matter and relationships among fluorescent components, absorption coefficients and dissolved organic carbon in the Bohai Sea, the Yellow Sea and the East China Sea

    Zhu, Wen-Zhuo; Zhang, Hong-Hai; Zhang, Jing; Yang, Gui-Peng

    2018-04-01

    The absorption coefficient and fluorescent components of chromophoric dissolved organic matter (CDOM) in the Bohai Sea (BS), Yellow Sea (YS), and East China Sea (ECS) in spring and autumn were analyzed in this study. Excitation-emission matrices (EEMs) combined with parallel factor analysis (PARAFAC) identified three components, namely, humic-like C1, tyrosine-like C2 and tryptophan-like C3. The seasonal variations in the vertical patterns of the CDOM absorption coefficient (aCDOM(355)) and fluorescent components were influenced by the seasonal water mass except for the terrestrial input. The relationship between aCDOM(355) and dissolved organic matter (DOC) was attributed to their own mixing behavior. The correlation of the fluorescent components with DOC was disturbed by other non-conservative processes during the export of CDOM to the open ocean. The different chemical compositions and origins of DOC and CDOM led to variability in carbon-specific CDOM absorption (a*CDOM(355)) and fluorescent component ratios (ICn/IC1). The relationship between a*CDOM(355) and aCDOM(355) demonstrated that dissolved organic matter (DOM) in the BS, but not in the ECS, highly contributed non-absorbing DOC to the total DOC concentration. The photodegradation of dominant terrestrially derived CDOM in the ECS contributed to the positive relationship between a*CDOM(355) and ICn/IC1. By contrast, the abundant autochthonous CDOM in the YS was negatively correlated with ICn/IC1 in autumn. Our established box models showed that water exchange is a potentially important source of the aromatic components in the BS, YS, and ECS. Hence, the seasonal variations in water exchange might contribute to the variability of CDOM chemical composition in the BS, YS, and ECS, and significantly influence the structure and function of their ecosystems.

  8. Improved spectral absorption coefficient grouping strategy of wide band k-distribution model used for calculation of infrared remote sensing signal of hot exhaust systems

    Hu, Haiyang; Wang, Qiang

    2018-07-01

    A new strategy for grouping spectral absorption coefficients, considering the influences of both temperature and species mole ratio inhomogeneities on correlated-k characteristics of the spectra of gas mixtures, has been deduced to match the calculation method of spectral overlap parameter used in multiscale multigroup wide band k-distribution model. By comparison with current spectral absorption coefficient grouping strategies, for which only the influence of temperature inhomogeneity on the correlated-k characteristics of spectra of single species was considered, the improvements in calculation accuracies resulting from the new grouping strategy were evaluated using a series of 0D cases in which radiance under 3-5-μm wave band emitted by hot combustion gas of hydrocarbon fuel was attenuated by atmosphere with quite different temperature and mole ratios of water vapor and carbon monoxide to carbon dioxide. Finally, evaluations are presented on the calculation of remote sensing thermal images of transonic hot jet exhausted from a chevron ejecting nozzle with solid wall cooling system.

  9. Absorption coefficient and relative refractive index change for a double δ-doped GaAs MIGFET-like structure: Electric and magnetic field effects

    Martínez-Orozco, J. C.; Rodríguez-Magdaleno, K. A.; Suárez-López, J. R.; Duque, C. A.; Restrepo, R. L.

    2016-04-01

    In this work we present theoretical results for the electronic structure as well as for the absorption coefficient and relative refractive index change for an asymmetric double δ-doped like confining potential in the active region of a Multiple Independent Gate Field Effect Transistor (MIGFET) system. We model the potential profile as a double δ-doped like potential profile between two Schottky (parabolic) potential barriers that are just the main characteristics of the MIGFET configuration. We investigate the effect of external electromagnetic fields in this kind of quantum structures, in particular we applied a homogeneous constant electric field in the growth direction z as well as a homogeneous constant magnetic field in the x-direction. In general we conclude that by applying electromagnetic fields we can modulate the resonant peaks of the absorption coefficient as well as their energy position. Also with such probes it is possible to control the nodes and amplitude of the relative refractive index changes related to resonant intersubband optical transitions.

  10. Reduction in biomass burning aerosol light absorption upon humidification: roles of inorganically-induced hygroscopicity, particle collapse, and photoacoustic heat and mass transfer

    L. Liu

    2009-11-01

    Full Text Available Smoke particle emissions from the combustion of biomass fuels typical for the western and southeastern United States were studied and compared under high humidity and ambient conditions in the laboratory. The fuels used were Montana ponderosa pine (Pinus ponderosa, southern California chamise (Adenostoma fasciculatum, and Florida saw palmetto (Serenoa repens. Information on the non-refractory chemical composition of biomass burning aerosol from each fuel was obtained with an aerosol mass spectrometer and through estimation of the black carbon concentration from light absorption measurements at 870 nm. Changes in the optical and physical particle properties under high humidity conditions were observed for hygroscopic smoke particles containing substantial inorganic mass fractions that were emitted from combustion of chamise and palmetto fuels. Light scattering cross sections increased under high humidity for these particles, consistent with the hygroscopic growth measured for 100 nm particles in HTDMA measurements. Photoacoustic measurements of aerosol light absorption coefficients revealed a 20% reduction with increasing relative humidity, contrary to the expectation of light absorption enhancement by the liquid coating taken up by hygroscopic particles. This reduction is hypothesized to arise from two mechanisms: (1 shielding of inner monomers after particle consolidation or collapse with water uptake; (2 the lower case contribution of mass transfer through evaporation and condensation at high relative humidity (RH to the usual heat transfer pathway for energy release by laser-heated particles in the photoacoustic measurement of aerosol light absorption. The mass transfer contribution is used to evaluate the fraction of aerosol surface covered with liquid water solution as a function of RH.

  11. Reduction in biomass burning aerosol light absorption upon humidification: roles of inorganically-induced hygroscopicity, particle collapse, and photoacoustic heat and mass transfer

    Lewis, K. A.; Arnott, W. P.; Moosmüller, H.; Chakrabarty, R. K.; Carrico, C. M.; Kreidenweis, S. M.; Day, D. E.; Malm, W. C.; Laskin, A.; Jimenez, J. L.; Ulbrich, I. M.; Huffman, J. A.; Onasch, T. B.; Trimborn, A.; Liu, L.; Mishchenko, M. I.

    2009-11-01

    Smoke particle emissions from the combustion of biomass fuels typical for the western and southeastern United States were studied and compared under high humidity and ambient conditions in the laboratory. The fuels used were Montana ponderosa pine (Pinus ponderosa), southern California chamise (Adenostoma fasciculatum), and Florida saw palmetto (Serenoa repens). Information on the non-refractory chemical composition of biomass burning aerosol from each fuel was obtained with an aerosol mass spectrometer and through estimation of the black carbon concentration from light absorption measurements at 870 nm. Changes in the optical and physical particle properties under high humidity conditions were observed for hygroscopic smoke particles containing substantial inorganic mass fractions that were emitted from combustion of chamise and palmetto fuels. Light scattering cross sections increased under high humidity for these particles, consistent with the hygroscopic growth measured for 100 nm particles in HTDMA measurements. Photoacoustic measurements of aerosol light absorption coefficients revealed a 20% reduction with increasing relative humidity, contrary to the expectation of light absorption enhancement by the liquid coating taken up by hygroscopic particles. This reduction is hypothesized to arise from two mechanisms: (1) shielding of inner monomers after particle consolidation or collapse with water uptake; (2) the lower case contribution of mass transfer through evaporation and condensation at high relative humidity (RH) to the usual heat transfer pathway for energy release by laser-heated particles in the photoacoustic measurement of aerosol light absorption. The mass transfer contribution is used to evaluate the fraction of aerosol surface covered with liquid water solution as a function of RH.

  12. Mass attenuation coefficients of X-rays in different barite concrete used in radiation protection as shielding against ionizing radiation

    Almeida, A. T. Jr.; Nogueira, M.S.; Santos, M.A.P.; Campos, L.L.; Araújo, F. G. S.

    2015-01-01

    The attenuation coefficient depends on the incident photon energy and the nature of the materials. In order to minimize exposure to individuals. Barite concrete has been largely used as a shielding material in installations housing gamma radiation sources as well as X-ray generating equipment. This study was conducted to evaluate the efficacy of different mixtures of barite concrete for shielding in diagnostic X-ray rooms. The mass attenuation coefficient (μ/ρ). The mass attenuation coefficients have been measured by employing the CdTe detector model XR-100T. The distance between the source and the exposed surface of all samples was measured by SSD light indicator of machine which was 350 cm. The slope of the linear plot of the intensity transmitted versus specimen thickness would yield the attenuation coefficient. The mass attenuation coefficients (μ/ρ) were compared with the tabulations based upon the results of the XCOM program. The rectangular barite concrete blocks in different thicknesses from were used for the radiation attenuation test. The experimental values were compared with theoretical values WinXcom. The plots of the logarithm of transmitted intensity versus specimen thickness were linear for all the samples and the µ/ρ was obtained from the plots by linear regression over the 25%-2% transmission range, under good geometrical condition. There is a good agreement between theoretical and experimental values, within the 9%. In fact over the entire transmission range of 25-2% the experimental and theoretical values agree well for both the energies. (authors)

  13. The influence of surfactant on mass transfer coefficients in evaporation of volatile organic compound from water basin

    Bunyakan, C.

    2002-04-01

    Full Text Available Volatile organic compounds (VOCs have been found in wastewater of many chemical industries. Evaporation of VOCs from open water basin in waste treatment facilities causes air-pollution and has been regulated in many countries. Reduction or prevention of VOCs evaporation from open water basin is then necessary. The aim of this research was to investigate the influence of surface film generated by an insoluble surfactant on the mass transfer coefficient of VOCs evaporating from water. Hexadecanol and octadecanol were used as surfactant in this investigation with the amount in the range of 0 to 35 μg/cm2 and 0 to 25 μg/cm2, respectively. The VOCs used in this study were methanol, acetone, methyl ethyl ketone and toluene. The experimental results showed that the surfactant film can reduce the gas film and liquid coefficients by 56 and 80 %, respectively. The suitable amounts of the surfactant were 25 μg/cm2 for hexadecanol and 15 μg/cm2 for octadecanol. From this investigation we can conclude that covering the water surface with a film of hexadecanol or octadecanol could significantly reduce the VOCs evaporation rate.Finally, the empirical equations correlating gas film and liquid film coefficient to amount of surfactants were developed and verified against the experimental data. The predicted values of the overall mass transfer coefficients, obtained by using these empirical equations, were in good agreement with the measured values. Thus the empirical equations of mass transfer coefficients developed in this work can be used to predict the evaporation rates of VOCs from water surface covered by hexadecanol or octadecanol film.

  14. Computation of Added Mass and Damping Coefficients of a Horizontal Circular Cylinder in Open Foam

    Chen, Hao; Christensen, Erik Damgaard

    2016-01-01

    This paper presents numerical computation of added massand damping coefficients of a slender horizontal cylinder in thefree surface zone, which typically serves as a fish cage floater. A fully viscous two phase flow solver in OpenFOAM was employed in the numerical computation. The purpose...

  15. Correlation between octanol/water and liposome/water distribution coefficients and drug absorption of a set of pharmacologically active compounds.

    Esteves, Freddy; Moutinho, Carla; Matos, Carla

    2013-06-01

    Absorption and consequent therapeutic action are key issues in the development of new drugs by the pharmaceutical industry. In this sense, different models can be used to simulate biological membranes to predict the absorption of a drug. This work compared the octanol/water and the liposome/water models. The parameters used to relate the two models were the distribution coefficients between liposomes and water and octanol and water and the fraction of drug orally absorbed. For this study, 66 drugs were collected from literature sources and divided into four groups according to charge and ionization degree: neutral; positively charged; negatively charged; and partially ionized/zwitterionic. The results show a satisfactory linear correlation between the octanol and liposome systems for the neutral (R²= 0.9324) and partially ionized compounds (R²= 0.9367), contrary to the positive (R²= 0.4684) and negatively charged compounds (R²= 0.1487). In the case of neutral drugs, results were similar in both models because of the high fraction orally absorbed. However, for the charged drugs (positively, negatively, and partially ionized/zwitterionic), the liposomal model has a more-appropriate correlation with absorption than the octanol model. These results show that the neutral compounds only interact with membranes through hydrophobic bonds, whereas charged drugs favor electrostatic interactions established with the liposomes. With this work, we concluded that liposomes may be a more-appropriate biomembrane model than octanol for charged compounds.

  16. Measurement of the X-ray mass attenuation coefficients of silver in the 5-20 keV range.

    Islam, M Tauhidul; Tantau, Lachlan J; Rae, Nicholas A; Barnea, Zwi; Tran, Chanh Q; Chantler, Christopher T

    2014-03-01

    The X-ray mass attenuation coefficients of silver were measured in the energy range 5-20 keV with an accuracy of 0.01-0.2% on a relative scale down to 5.3 keV, and of 0.09-1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X-ray attenuation of high-Z elements can be measured with high accuracy even at low X-ray energies (silver in the low energy range, indicating the possibility of obtaining high-accuracy X-ray absorption fine structure down to the L1 edge (3.8 keV) of silver. Comparison of results reported here with an earlier data set optimized for higher energies confirms accuracy to within one standard error of each data set collected and analysed using the principles of the X-ray extended-range technique (XERT). Comparison with theory shows a slow divergence towards lower energies in this region away from absorption edges. The methodology developed can be used for the XAFS analysis of compounds and solutions to investigate structural features, bonding and coordination chemistry.

  17. Determination of the mass-transfer coefficient in liquid phase in a stream-bubble contact device

    Dmitriev, A. V.; Dmitrieva, O. S.; Madyshev, I. N.

    2016-09-01

    One of the most effective energy saving technologies is the improvement of existing heat and mass exchange units. A stream-bubble contact device is designed to enhance the operation efficiency of heat and mass exchange units. The stages of the stream-bubble units that are proposed by the authors for the decarbonization process comprise contact devices with equivalent sizes, whose number is determined by the required performance of a unit. This approach to the structural design eliminates the problems that arise upon the transition from laboratory samples to industrial facilities and makes it possible to design the units of any required performance without a decrease in the effectiveness of mass exchange. To choose the optimal design that provides the maximum effectiveness of the mass-exchange processes in units and their intensification, the change of the mass-transfer coefficient is analyzed with the assumption of a number of parameters. The results of the study of the effect of various structural parameters of a stream-bubble contact device on the mass-transfer coefficient in the liquid phase are given. It is proven that the mass-transfer coefficient increases in the liquid phase, in the first place, with the growth of the level of liquid in the contact element, because the rate of the liquid run-off grows in this case and, consequently, the time of surface renewal is reduced; in the second place, with an increase in the slot diameter in the downpipe, because the jet diameter and, accordingly, their section perimeter and the area of the surface that is immersed in liquid increase; and, in the third place, with an increase in the number of slots in the downpipe, because the area of the surface that is immersed in the liquid of the contact element increases. Thus, in order to increase the mass-transfer coefficient in the liquid phase, it is necessary to design the contact elements with a minimum width and a large number of slots and their increased diameter; in

  18. The influence of surfactant on mass transfer coefficients in evaporation of volatile organic compound from water basin

    Bunyakan, C.; Malakarn, S.; Tongurai, C.

    2002-01-01

    Volatile organic compounds (VOCs) have been found in wastewater of many chemical industries. Evaporation of VOCs from open water basin in waste treatment facilities causes air-pollution and has been regulated in many countries. Reduction or prevention of VOCs evaporation from open water basin is then necessary. The aim of this research was to investigate the influence of surface film generated by an insoluble surfactant on the mass transfer coefficient of VOCs evaporating from water. Hexadeca...

  19. Mass attenuation coefficient for X rays. Efficiency of a semiconducting diode

    Bardet, R.

    1977-03-01

    A critical review of usual values given in the litterature by tables or by analytical fit to experimental data, for X-ray absorption through different materials, is presented. The materials are those used in plasma physics experiments: Be, C, N, O, A1, Si, Ni, Au. Energy range is between 100eV and 100keV. An illustration is given by the estimation of efficiency of a silicon surface barrier detector with partial depletion [fr

  20. MASS TRANSFER COEFFICIENTS FOR A NON-NEWTONIAN FLUID AND WATER WITH AND WITHOUT ANTI-FOAM AGENTS

    Leishear, R.

    2009-09-09

    Mass transfer rates were measured in a large scale system, which consisted of an 8.4 meter tall by 0.76 meter diameter column containing one of three fluids: water with an anti-foam agent, water without an anti-foam agent, and AZ101 simulant, which simulated a non-Newtonian nuclear waste. The testing contributed to the evaluation of large scale mass transfer of hydrogen in nuclear waste tanks. Due to its radioactivity, the waste was chemically simulated, and due to flammability concerns oxygen was used in lieu of hydrogen. Different liquids were used to better understand the mass transfer processes, where each of the fluids was saturated with oxygen, and the oxygen was then removed from solution as air bubbled up, or sparged, through the solution from the bottom of the column. Air sparging was supplied by a single tube which was co-axial to the column, the decrease in oxygen concentration was recorded, and oxygen measurements were then used to determine the mass transfer coefficients to describe the rate of oxygen transfer from solution. Superficial, average, sparging velocities of 2, 5, and 10 mm/second were applied to each of the liquids at three different column fill levels, and mass transfer coefficient test results are presented here for combinations of superficial velocities and fluid levels.

  1. MASS TRANSFER COEFFICIENTS FOR A NON-NEWTONIAN FLUID AND WATER WITH AND WITHOUT ANTI-FOAM AGENTS

    Leishear, R.

    2009-01-01

    Mass transfer rates were measured in a large scale system, which consisted of an 8.4 meter tall by 0.76 meter diameter column containing one of three fluids: water with an anti-foam agent, water without an anti-foam agent, and AZ101 simulant, which simulated a non-Newtonian nuclear waste. The testing contributed to the evaluation of large scale mass transfer of hydrogen in nuclear waste tanks. Due to its radioactivity, the waste was chemically simulated, and due to flammability concerns oxygen was used in lieu of hydrogen. Different liquids were used to better understand the mass transfer processes, where each of the fluids was saturated with oxygen, and the oxygen was then removed from solution as air bubbled up, or sparged, through the solution from the bottom of the column. Air sparging was supplied by a single tube which was co-axial to the column, the decrease in oxygen concentration was recorded, and oxygen measurements were then used to determine the mass transfer coefficients to describe the rate of oxygen transfer from solution. Superficial, average, sparging velocities of 2, 5, and 10 mm/second were applied to each of the liquids at three different column fill levels, and mass transfer coefficient test results are presented here for combinations of superficial velocities and fluid levels

  2. A comparison of mass transfer coefficients between trickle-bed, hollow fiber membrane and stirred tank reactors.

    Orgill, James J; Atiyeh, Hasan K; Devarapalli, Mamatha; Phillips, John R; Lewis, Randy S; Huhnke, Raymond L

    2013-04-01

    Trickle-bed reactor (TBR), hollow fiber membrane reactor (HFR) and stirred tank reactor (STR) can be used in fermentation of sparingly soluble gasses such as CO and H2 to produce biofuels and bio-based chemicals. Gas fermenting reactors must provide high mass transfer capabilities that match the kinetic requirements of the microorganisms used. The present study compared the volumetric mass transfer coefficient (K(tot)A/V(L)) of three reactor types; the TBR with 3 mm and 6 mm beads, five different modules of HFRs, and the STR. The analysis was performed using O2 as the gaseous mass transfer agent. The non-porous polydimethylsiloxane (PDMS) HFR provided the highest K(tot)A/V(L) (1062 h(-1)), followed by the TBR with 6mm beads (421 h(-1)), and then the STR (114 h(-1)). The mass transfer characteristics in each reactor were affected by agitation speed, and gas and liquid flow rates. Furthermore, issues regarding the comparison of mass transfer coefficients are discussed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. On development of analytical closure relationships for local wall friction, heat and mass transfer coefficients for sub-channel codes

    Kornienko, Y.

    2000-01-01

    The purpose has been to describe an approach suggested for constructing generalized closure relationships for local and subchannel wall friction, heat and mass transfer coefficients, with not only axial and transversal parameters taken into account, but azimuthal substance transfer effects as well. These constitutive relations that are primary for description of one- and two-phase one-dimensional flow models can be derived from the initial 3-D drift flux formulation. The approach is based on the Reynolds flux, boundary layer and generalized coefficient of substance transfer. One more task has been to illustrate the validity of the 'conformity principle' for the limiting cases. The method proposed is based on the similarity theory, boundary layer model, and a phenomenological description of the regularities of the substance transfer (momentum, heat, and mass), as well as on an adequate simulation of the forms of flow structure by a generalized approach to build (an integrated in form and semi-empirical in maintenance structure) analytical relationships for wall friction, heat and mass transfer coefficients. (author)

  4. Rapid yet accurate measurement of mass diffusion coefficients by phase shifting interferometer

    Guo Zhi Xiong; Komiya, A

    1999-01-01

    The technique of using a phase-shifting interferometer is applied to the study of diffusion in transparent liquid mixtures. A quick method is proposed for determining the diffusion coefficient from the measurements of the location of fringes on a grey level picture. The measurement time is very short (within 100 s) and a very small transient diffusion field can be observed and recorded accurately with a rate of 30 frames per second. The measurement can be completed using less than 0.12 cc of solutions. The influence of gravity on the measurement of the diffusion coefficient is eliminated in the present method. Results on NaCl-water diffusion systems are presented and compared with the reference data. (author)

  5. Determination of heat and mass transfer coefficients in a rotary shaker used in fermentation processes

    Mario Arias Zabala

    2001-01-01

    Full Text Available In this paper the volumetric oxygen transfer (kLa and overall heat transfer (Ua coefficients were determined in flasks which were subjected to rotary shaker action, also provided with a temperature control chamber. Likewise, it was determined the effect over such coefficients of some parameters like surrounding temperature, shaking speed, closure type, liquid volume, capacity and baffles presence or absence in each flask, to determine the optimal work conditions in the rotary shaker. The used liquid in these experiments was distilled water. The kLa and Ua coefficients were also determined in the alcoholic fermentation of glucose by Saccharomyces cerevisiae yeast, in order to establish comparison standards. The maximum and minimum values of referred coefficients to distilled water and the operation conditions were:   kLa of 6.2 x 10-3 s-1, working at 25 ºC, 100 rpm, 50 ml of liquid volume, erlenmeyer of 500 ml with baffles and plastic closure. kLa of 4.107 x 10-3 s-1, working at 45 ºC, 60 rpm, 150 ml of liquid volume, erlenmeyer of 250 ml without baffles and cotton closure. Ua of 31.9963 J/min °C, working at 45 ºC, 150 rpm, 150 ml of liquid volume, erlenmeyer of 500 ml with baffles and cotton closure. Ua of 6.0179 J/min °C, working at 35 ºC, 60 rpm, 50 ml of liquid volume, erlenmeyer of 250 ml without baffles and plastic closure. The kLa and Ua values in the alcoholic fermentation and the operation conditions were: kLa of 2.6 x 10-4 s-1 and Ua of 12.8907 J/min °C, working at 35 °C, 150 rpm, 150 ml of liquid volume, Erlenmeyer of 250 ml, with baffles and cotton closure.

  6. Application of the two-film theory to the determination of mass transfer coefficients for bovine serum albumin on anion-exchange columns

    Hansen, Ernst; Mollerup, Jørgen

    1999-01-01

    The paper describes a method of simultaneous determination of the external and the solid phase mass-transfer coefficients from frontal analysis data. The protein flux to the solid particles is determined from the slope of the breakthrough curve and the mass-transfer coefficients are determined...

  7. Aerosol absorption coefficient and Equivalent Black Carbon by parallel operation of AE31 and AE33 aethalometers at the Zeppelin station, Ny Ålesund, Svalbard

    Eleftheriadis, Konstantinos; Kalogridis, Athina-Cerise; Vratolis, Sterios; Fiebig, Markus

    2016-04-01

    Light absorbing carbon in atmospheric aerosol plays a critical role in radiative forcing and climate change. Despite the long term measurements across the Arctic, comparing data obtained by a variety of methods across stations requires caution. A method for extracting the aerosol absorption coefficient from data obtained over the decades by filter based instrument is still under development. An IASOA Aerosol working group has been initiated to address this and other cross-site aerosol comparison opportunities. Continuous ambient measurements of EBC/light attenuation by means of a Magee Sci. AE-31 aethalometer operating at the Zeppelinfjellet station (474 m asl; 78°54'N, 11°53'E), Ny Ålesund, Svalbard, have been available since 2001 (Eleftheriadis et al, 2009), while a new aethalometer model (AE33, Drinovec et al, 2014) has been installed to operate in parallel from the same inlet since June 2015. Measurements are recorded by a Labview routine collecting all available parameters reported by the two instrument via RS232 protocol. Data are reported at 1 and 10 minute intervals as averages for EBC (μg m-3) and aerosol absorption coefficients (Mm-1) by means of routine designed to report Near Real Time NRT data at the EBAS WDCA database (ebas.nilu.no) Results for the first 6 month period are reported here in an attempt to evaluate comparative performance of the two instruments in terms of their response with respect to the variable aerosol load of light absorbing carbon during the warm and cold seasons found in the high arctic. The application of available conversion schemes for obtaining the absorption coefficient by the two instruments is found to demonstrate a marked difference in their output. During clean periods of low aerosol load (EBC origin was also conducted. Drinovec, L., Močnik, G., Zotter, P., Prévôt, A. S. H., Ruckstuhl, C., Coz, E., Rupakheti, M., Sciare, J., Müller, T., Wiedensohler, A., and Hansen, A. D. A. The "dual-spot" Aethalometer: an

  8. Absorption dynamics of organic chemical transport across trout gills as related to octanol-water partition coefficient

    McKim, J.; Schmieder, P.; Veith, G.

    1985-01-01

    An in vivo fish preparation was used that allowed a direct measure of the transport rates of 14 different organic chemicals across the gills of rainbow trout (Salmo gairdneri). The chemicals, all C14 labeled, were selected from five classes, encompassing a range of octanol-water partition coefficient (log P) values, from 0.23 (ethyl formate) to 7.5 (mirex). The uptake efficiency (extraction efficiency) of each chemical was determined by monitoring the inspired and expired water of trout exposed to each chemical over an exposure period of 1 to 6 hr. The mean gill extraction efficiency for all chemicals tested varied from a low of 7% to a high of 60%, extracted in a single pall of the chemical across the gills. The extraction efficiency of chemicals with log P or 1 or less were low and showed no relationship to log P. These low extraction efficiencies seen at log P of 1 and below with molecular weights below 100 were indicative of aqueous pore transport. The mean extraction efficiency for chemicals with log P values of 1 to 3 seemed to vary directly with log P, to a maximum of slightly greater than 60%, suggesting that uptake was controlled by the lipid membrane. The mean extraction efficiency for chemicals with log P of 3 to 6 was independent of log P and remained at 60%, which suggested that gill uptake was controlled by aqueous diffusion rates rather than gill membrane permeability. The mean extraction efficiency with mirex (log P . 7.5) decreased to 20%

  9. Determination of volumetric gas-liquid mass transfer coefficient of carbon monoxide in a batch cultivation system using kinetic simulations.

    Jang, Nulee; Yasin, Muhammad; Park, Shinyoung; Lovitt, Robert W; Chang, In Seop

    2017-09-01

    A mathematical model of microbial kinetics was introduced to predict the overall volumetric gas-liquid mass transfer coefficient (k L a) of carbon monoxide (CO) in a batch cultivation system. The cell concentration (X), acetate concentration (C ace ), headspace gas (N co and [Formula: see text] ), dissolved CO concentration in the fermentation medium (C co ), and mass transfer rate (R) were simulated using a variety of k L a values. The simulated results showed excellent agreement with the experimental data for a k L a of 13/hr. The C co values decreased with increase in cultivation times, whereas the maximum mass transfer rate was achieved at the mid-log phase due to vigorous microbial CO consumption rate higher than R. The model suggested in this study may be applied to a variety of microbial systems involving gaseous substrates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Estimation of the mass absorption cross-section of the black and brown carbon aerosols during GoPoEx 2014

    Cho, C.; Kim, S. W.; Lee, M.; Gustafsson, O.; Fang, W.

    2017-12-01

    Black carbon (BC) is a major contributor to the atmospheric heating by absorbing the solar radiation. According to recent studies, the solar absorption of brown carbon (BrC) is not negligible and even comparable to that of BC at visible to UV wavelengths, but most optical instruments that quantify light absorption are unable to distinguish each other. Thus, light absorption properties of BC or BrC usually have been studied through modeling researches by using mass absorption cross-section (MAC). Although MAC has a large spatial and temporal variability, most modeling studies have used a specific value of BC MAC and even the absorption by BrC is seldom considered in most chemical and climate models. The generalization of modeling research can lead to serious errors of radiative forcing by BC and BrC. In this study, MAC of BC and BrC are separately determined and the contribution of BC and BrC on aerosol light absorption are estimated from co-located simultaneous in-situ measurements, COSMOS, CLAP and Sunset EC/OC analyzer, at Gosan climate observatory, Korea during Gosan Pollution Experiment in January 2014 (GoPoEx 2014). At 565 nm, MAC of BC is found to be about 6.4±1.5 m2 g-1 from COSMOS and Sunset EC/OC analyzer measurements. This value is similar to those from previous studies in China (Cui et al., STE, 2016), but lower than those observed to be ranged 10-18 m2 g-1 in America or Europe (Lack et al., PNAS, 2012). Aerosol absorption coefficient (AAC) and BC mass concentration from COSMOS, meanwhile, are approximately 15-20% lower than those of CLAP. This difference can be attributable to the contribution of BrC. The MAC of BrC was calculated using the absorption coefficient of BrC and by the following three methods: (1) the difference of mass concentration from Aethalometer and COSMOS applied new BC MAC of this study, (2) The mass concentration of water-soluble organic carbon, (3) a method using the mass concentration of organic carbon suggested by Chung et al

  11. Nonlinear absorption coefficient and relative refraction index change for an asymmetrical double δ-doped quantum well in GaAs with a Schottky barrier potential

    Rojas-Briseño, J.G.; Martínez-Orozco, J.C.; Rodríguez-Vargas, I.; Mora-Ramos, M.E.; Duque, C.A.

    2013-01-01

    In this work we are reporting the energy level spectrum for a quantum system consisting of an n-type double δ-doped quantum well with a Schottky barrier potential in a Gallium Arsenide matrix. The calculated states are taken as the basis for the evaluation of the linear and third-order nonlinear contributions to the optical absorption coefficient and to the relative refractive index change, making particular use of the asymmetry of the potential profile. These optical properties are then reported as a function of the Schottky barrier height (SBH) and the separation distance between the δ-doped quantum wells. Also, the effects of the application of hydrostatic pressure are studied. The results show that the amplitudes of the resonant peaks are of the same order of magnitude of those obtained in the case of single δ-doped field effect transistors; but tailoring the asymmetry of the confining potential profile allows the control the resonant peak positions

  12. Nonlinear absorption coefficient and relative refraction index change for an asymmetrical double δ-doped quantum well in GaAs with a Schottky barrier potential

    Rojas-Briseño, J.G.; Martínez-Orozco, J.C.; Rodríguez-Vargas, I. [Unidad Académica de Física, Universidad Autónoma de Zacatecas, Calzada Solidaridad esquina con Paseo la Bufa S/N, C.P. 98060, Zacatecas, Zac. (Mexico); Mora-Ramos, M.E. [Facultad de Ciencias, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Instituto de Física, Universidad de Antioquia, AA 1226, Medellín (Colombia); Duque, C.A., E-mail: cduque@fisica.udea.edu.co [Instituto de Física, Universidad de Antioquia, AA 1226, Medellín (Colombia)

    2013-09-01

    In this work we are reporting the energy level spectrum for a quantum system consisting of an n-type double δ-doped quantum well with a Schottky barrier potential in a Gallium Arsenide matrix. The calculated states are taken as the basis for the evaluation of the linear and third-order nonlinear contributions to the optical absorption coefficient and to the relative refractive index change, making particular use of the asymmetry of the potential profile. These optical properties are then reported as a function of the Schottky barrier height (SBH) and the separation distance between the δ-doped quantum wells. Also, the effects of the application of hydrostatic pressure are studied. The results show that the amplitudes of the resonant peaks are of the same order of magnitude of those obtained in the case of single δ-doped field effect transistors; but tailoring the asymmetry of the confining potential profile allows the control the resonant peak positions.

  13. Determination of the quasi-TE mode (in-plane) graphene linear absorption coefficient via integration with silicon-on-insulator racetrack cavity resonators.

    Crowe, Iain F; Clark, Nicholas; Hussein, Siham; Towlson, Brian; Whittaker, Eric; Milosevic, Milan M; Gardes, Frederic Y; Mashanovich, Goran Z; Halsall, Matthew P; Vijayaraghaven, Aravind

    2014-07-28

    We examine the near-IR light-matter interaction for graphene integrated cavity ring resonators based on silicon-on-insulator (SOI) race-track waveguides. Fitting of the cavity resonances from quasi-TE mode transmission spectra reveal the real part of the effective refractive index for graphene, n(eff) = 2.23 ± 0.02 and linear absorption coefficient, α(gTE) = 0.11 ± 0.01dBμm(-1). The evanescent nature of the guided mode coupling to graphene at resonance depends strongly on the height of the graphene above the cavity, which places limits on the cavity length for optical sensing applications.

  14. Effect Of Particle Size Of Zeolite On The Mass Transfer Coefficient Of Strontium In The Radioactive Waste Ion-Exchange Process

    Dewi-Susilowati; Suyitno

    1998-01-01

    This research is aimed for finding out the volumetric mass transfer coefficient of the zeolite particle, ks. The experiment has been conducted using an ion exchange column. The column diameter and length are 4.2 cm and 28 cm, respectively. The experiments have been conducted by flowing in the feed to the ion-exchange column containing zeolite with the varied particle diameters, I.e. 20, 40, 60, 80 and 100 mesh. The feed concentrations of Sr(NO 3 ) 2 , have been varied, I.e. 100, 250, 450, 550 and 650 ppm, and so have been the flow rates, I.e/ 35, 49, 70, 90 and 105 ml/minute. Samples of the effluents have been taken at certain series of time and subjected to analysis using an Atomic Absorption Spectrophotometer. The analytical data obtained have shown that the mass transfer coefficient of the zeolite particle is predominantly affected by the zeolite structure, in particular is effected by the number of AI atoms that hold the K ions. The analytical result from the above parameters has been presented in the forms of several groups of dimensionless number. The equations obtained are: (k L *dp)/D L 18.902(Re) 0 ,378 (dp/D) 0 ,6972(Co * ) 0 ,2667 with a mean error of 7.26%; k S 2240.268(dp/D) 1 .553; and each of them is valid in range of: Re: 0.182 - 0.856; dp/D: 0.004 - 0.022; Co * : 9.5408x10 - 5 - 6.2827x10 - 4

  15. High absorption coefficients of the CuSb(Se,Te2 and CuBi(S,Se2 alloys enable high-efficient 100 nm thin-film photovoltaics

    Chen Rongzhen

    2017-01-01

    Full Text Available We demonstrate that the band-gap energies Eg of CuSb(Se,Te2 and CuBi(S,Se2 can be optimized for high energy conversion in very thin photovoltaic devices, and that the alloys then exhibit excellent optical properties, especially for tellurium rich CuSb(Se1−xTex2. This is explained by multi-valley band structure with flat energy dispersions, mainly due to the localized character of the Sb/Bi p-like conduction band states. Still the effective electron mass is reasonable small: mc ≈ 0.25m0 for CuSbTe2. The absorption coefficient α(ω for CuSb(Se1−xTex2 is at ħω = Eg + 1 eV as much as 5–7 times larger than α(ω for traditional thin-film absorber materials. Auger recombination does limit the efficiency if the carrier concentration becomes too high, and this effect needs to be suppressed. However with high absorptivity, the alloys can be utilized for extremely thin inorganic solar cells with the maximum efficiency ηmax ≈ 25% even for film thicknesses d ≈ 50 − 150 nm, and the efficiency increases to ∼30% if the Auger effect is diminished.

  16. High absorption coefficients of the CuSb(Se,Te)2 and CuBi(S,Se)2 alloys enable high-efficient 100 nm thin-film photovoltaics

    Chen, Rongzhen; Persson, Clas

    2017-06-01

    We demonstrate that the band-gap energies Eg of CuSb(Se,Te)2 and CuBi(S,Se)2 can be optimized for high energy conversion in very thin photovoltaic devices, and that the alloys then exhibit excellent optical properties, especially for tellurium rich CuSb(Se1-xTex)2. This is explained by multi-valley band structure with flat energy dispersions, mainly due to the localized character of the Sb/Bi p-like conduction band states. Still the effective electron mass is reasonable small: mc ≈ 0.25m0 for CuSbTe2. The absorption coefficient α(ω) for CuSb(Se1-xTex)2 is at ħω = Eg + 1 eV as much as 5-7 times larger than α(ω) for traditional thin-film absorber materials. Auger recombination does limit the efficiency if the carrier concentration becomes too high, and this effect needs to be suppressed. However with high absorptivity, the alloys can be utilized for extremely thin inorganic solar cells with the maximum efficiency ηmax ≈ 25% even for film thicknesses d ≈ 50 - 150 nm, and the efficiency increases to ˜30% if the Auger effect is diminished.

  17. Mass transfer coefficient in disturbed flow due to orifice for flow accelerated corrosion in nuclear power plant

    Prasad, Mahendra; Gaikwad, Avinash J.; Sridharan, Arunkumar; Parida, Smrutiranjan

    2015-01-01

    The flow of fluid in pipes cause corrosion wherein the inner surface of pipe becomes progressively thinner and susceptible to failure. This form of corrosion dependent on flow dynamics is called Flow Accelerated Corrosion (FAC) and has been observed in Nuclear Power Plants (NPPs). Mass transfer coefficient (MTC) is related to extent of wall thinning and it changes from its value in a straight pipe (with same fluid parameters) for flow in orifices, bends, junctions etc. due to gross disturbance of the velocity profile. This paper presents two-dimensional computational fluid dynamics (CFD) simulations for an orifice configuration in a straight pipe. Turbulent model K- ω with shear stress transport and transition flow was the model used for simulation studies. The mass transfer boundary layer (MTBL) thickness δ mtbl is related to the Schmidt number (Sc) and hydrodynamic boundary layer thickness δ h , as δ mtbl ~ δh/(Sc 1/3 ). MTBL is significantly smaller than δ h and hence boundary layer meshing was carried out deep into δ mtbl . Uniform velocity profile was applied at the inlet. Post orifice fluid shows large recirculating flows on the upper and lower wall. At various locations after orifice, mass transfer coefficient is calculated and compared with the value in straight pipe with fully developed turbulent flow. The MTC due to the orifice increases and it is correlated with enhanced FAC in region after orifice. (author)

  18. A Limit on the Warm Dark Matter Particle Mass from the Redshifted 21 cm Absorption Line

    Safarzadeh, Mohammadtaher; Scannapieco, Evan; Babul, Arif

    2018-06-01

    The recent Experiment to Detect the Global Epoch of Reionization Signature (EDGES) collaboration detection of an absorption signal at a central frequency of ν = 78 ± 1 MHz points to the presence of a significant Lyα background by a redshift of z = 18. The timing of this signal constrains the dark matter particle mass (m χ ) in the warm dark matter (WDM) cosmological model. WDM delays the formation of small-scale structures, and therefore a stringent lower limit can be placed on m χ based on the presence of a sufficiently strong Lyα background due to star formation at z = 18. Our results show that coupling the spin temperature to the gas through Lyα pumping requires a minimum mass of m χ > 3 keV if atomic cooling halos dominate the star formation rate at z = 18, and m χ > 2 keV if {{{H}}}2 cooling halos also form stars efficiently at this redshift. These limits match or exceed the most stringent limits cited to date in the literature, even in the face of the many uncertainties regarding star formation at high redshift.

  19. Conversion of time-varying Stokes coefficients into mass anomalies at the Earth's surface considering the Earth's oblateness

    Ditmar, Pavel

    2018-02-01

    Time-varying Stokes coefficients estimated from GRACE satellite data are routinely converted into mass anomalies at the Earth's surface with the expression proposed for that purpose by Wahr et al. (J Geophys Res 103(B12):30,205-30,229, 1998). However, the results obtained with it represent mass transport at the spherical surface of 6378 km radius. We show that the accuracy of such conversion may be insufficient, especially if the target area is located in a polar region and the signal-to-noise ratio is high. For instance, the peak values of mean linear trends in 2003-2015 estimated over Greenland and Amundsen Sea embayment of West Antarctica may be underestimated in this way by about 15%. As a solution, we propose an updated expression for the conversion of Stokes coefficients into mass anomalies. This expression is based on the assumptions that: (i) mass transport takes place at the reference ellipsoid and (ii) at each point of interest, the ellipsoidal surface is approximated by the sphere with a radius equal to the current radial distance from the Earth's center ("locally spherical approximation"). The updated expression is nearly as simple as the traditionally used one but reduces the inaccuracies of the conversion procedure by an order of magnitude. In addition, we remind the reader that the conversion expressions are defined in spherical (geocentric) coordinates. We demonstrate that the difference between mass anomalies computed in spherical and ellipsoidal (geodetic) coordinates may not be negligible, so that a conversion of geodetic colatitudes into geocentric ones should not be omitted.

  20. Methods for measuring nuclear properties of materials, Safety coefficient method and measurement of effective absorption coefficient of graphite by safety coefficient method; Razvijanje metoda merenja nuklearnih karakteristika materijala, Razrada metode koeficijenta opasnosti i merenje efektivnog apsorpcionog preseka grafita metodom koeficijenta opasnosti

    Maglic, R [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1962-11-15

    Reactivity of a reactor depends on production, absorption and leaking of neutrons. Change of absorption causes reactivity change, and this fact is used for determining the neutron absorption cross section for the sample inserted in the reactor core. Method for determining the absorption cross section based on reactivity change is called method of safety coefficient. Measurements of neutron absorption cross section for graphite was done in the RA reactor vertical experimental channel VK-5. taking into account the results obtained for five types of graphite this method is considered to be reliable for use. Comparison of nuclear properties of different types of graphite was done as well. Reaktivnost reaktora zavisi od proizvodnje neutrona, apsorpcije i isticanja neutrona. Promena apsorpcije izaziva promene reaktivnosti reaktora pa se ova osobina koristi za odedjivanje neutronskog apsorpcionog preseka uzorka koji se unosi u reaktor. Metoda merenja apsorpcionog preseka na bazi promene reaktivnosti nazvana je metodom koeficijenta opasnosti. Merenje apsorpcionog preseka grafita uradjeno je na reaktoru RA u vertikalnom eksperimentalnom kanalu VK-5. S obzirom na rezultate koji su dobijeni za pet vrsta grafita moze se smatrati da je opravdano koriscenje ove metode. Izvrseno je i poredjenje nuklearnih osobina pomenutih tipova grafita.

  1. Theoretical and experimental determination of mass attenuation coefficients of lead-based ceramics and their comparison with simulation

    Vejdani-Noghreiyan Alireza

    2016-01-01

    Full Text Available Mass attenuation coefficient of lead-based ceramics have been measured by experimental methods and compared with theoretical and Monte Carlo simulation results. Lead-based ceramics were prepared using mixed oxide method and the X-ray diffraction analysis was done to evaluate the crystal structure of the produced handmade ceramics. The experimental results show good agreement with theoretical and simulation results. However at two gamma ray energies, small differences between experimental and theoretical results have been observed. By adding other additives to ceramics and observing the changes in the shielding properties such as flexibility, one can synthesize and optimize ceramics as a neutron shield.

  2. Study of mass attenuation coefficients and effective atomic numbers of bismuth-ground granulated blast furnace slag concretes

    Kumar, Sandeep; Singh, Sukhpal

    2016-01-01

    Five samples of Bismuth-Ground granulated blast furnace slag (Bi-GGBFS) concretes were prepared using composition (0.6 cement + x Bi_2O_3 + (0.4-x) GGBFS, x = 0.05, 0.10, 0.15, 0.20 and 0.25) by keeping constant water (W) cement (C) ratio. Mass attenuation coefficients (μ_m) of these prepared samples were calculated using a computer program winXCOM at different gamma ray energies, whereas effective atomic numbers (Z_e_f_f) is calculated using mathematical formulas. The radiation shielding properties of Bi-GGBFS concrete has been compared with standard radiation shielding concretes.

  3. Effect of some additives on mass transfer coefficient at a vibrating horizontal screen

    Nosier, S.A.; El-Abd, M.Z. [Chemical Engineering Dept., Faculty of Engineering, Alexandria Univ. (Egypt); Zaki, M.M. [Environmental Engineering Dept., Faculty of Engineering, Zagazig Univ. (Egypt)

    1998-01-01

    The addition of small amounts of high molecular weight substances, such as polymers and surface-active agents, to fluids can produce significant reduction of friction in turbulent flow. The objectiv of the present work is to study the effect of drag-reducing additives such as Polyox WSR 301 and sodium lauryl sulfate (anionic surfactant) on the rate of mass transfer at a vibrating horizontal screen. The variables studied were the concentration of polymer and surfactant, frequency of vibration and amplitude of vibration. (orig.)

  4. Comparison of experimental methods for determination of the volumetric mass transfer coefficient in fermentation processes

    Tobajas, M.; Garcia-Calvo, E. [Dept. de Ingenieria Quimica, Univ. de Alcala, Alcala de Henares (Spain)

    2000-05-01

    Mass transfer in bioreactors has been examined. In the present work, dynamic methods are used for the determination of K{sub L}a values for water, model media and a fermentation broth (Candida utilis) in an airlift reactor. The conventional dynamic method is applied at the end of the microbial process in order to avoid an alteration in the metabolism of the microorganisms. New dynamic methods are used to determine K{sub L}a in an airlift reactor during the microbial growth of Candida utilis on glucose. One of the methods is based on the continuous measurement of carbon dioxide production while the other method is based on the relationship between the oxygen transfer and biomass growth rates. These methods of determining K{sub L}a does not interfere with the microorganisms action. A theoretical mass transfer model has been used for K{sub L}a estimation for the systems described above. Some differences between calculated and measured values are found for fermentation processes due to the model is developed for two-phase air-water systems. Nevertheless, the average deviation between the predicted values and those obtained from the relationship between oxygen transfer and biomass production rates are lower than 25% in any case. (orig.)

  5. The value of the apparent diffusion coefficient in MR diffusion weighted imaging for the differential diagnosis of sinonasal masses

    Wang Yongzhe; Yang Bentao; Xian Junfang; Li Jing; Chen Guangli

    2014-01-01

    Objective: To investigate the diagnostic value of apparent diffusion coefficient in the evaluation of sinonasal masses. Methods: Sixty-seven sinonasal solid masses over 1 cm in diameter confirmed by pathology were retrospectively analyzed, all patients underwent preoperative routine MRI with DWI, the ADC values were measured in ROI within the solid mass. The patients were divided into benign and malignant groups by the histopathology, according to pathological findings, the patients were further divided into the hematolymphoid tumors, the malignancy of epithelium and mesenchymal tissue, the benign tumors of epithelial and mesenchymal tissue, and vasogenic masses. ANOVA test and t test were used to compare the ADC values of different groups. The receiver operating characteristic curve (ROC) was constructed using various cut points of ADC for different parameters to confirm the diagnostic threshold value and evaluate the diagnostic efficacy. Results: All lesions were solitary. There were 22 malignant tumors, of which 6 lesions were hematolymphoid tumors and 16 lesions malignancy from epithelium and mesenchymal tissue. There were 45 benign tumors, of which 22 lesions were benign tumors from epithelium and mesenchymal tissue and 23 lesions vasogenic masses. The mean ADC value of malignant and benign masses was (0.88 ± 0.26) × 10 -3 mm 2 /s and (1.54 ± 0.41) × 10 -3 mm 2 /s respectively. There was statistically significant differences between them (t=6.897, P <0.01). The mean ADC value was(0.63 ± 0.10) × 10 -3 mm 2 /s in hematolymphoid tumors,(0.97 ±0.24) × 10 -3 mm 2 /s in malignancy from epithelium and mesenchymal tissue, (1.38 ± 0.23) × 10 -3 mm 2 /s in benign tumors from epithelium and mesenchymal tissue,(1.68 ± 0.49) × 10 -3 mm 2 /s in vasogenic masses respectively. There was statistically significant difference among all 4 groups(F=22.788, P<0.01), and the differences between any 2 groups were still statistically significant (P <0.05). The area under

  6. Effects of organometallic chelates and inulin in diets for laying hens on Mn and Fe absorption coefficients and their content in egg and tissue

    Cornescu Gabriela Maria

    2015-01-01

    Full Text Available The aim of this study was to evaluate effects of organic sources of manganese (Mn and iron (Fe and inulin in diets for laying hens on absorption of these minerals and their deposition in egg and tissue. The study was conducted on 90 Lohmann Brown laying hens in the period from 46-52 weeks of age, assigned to 3 groups with 30 hens/group and 3 hens/cage. The hens from the control group (C received a diet based on corn, rice bran and soybean meal with 16% of crude protein, as well as 60 mg Fe/kg and 71.9 mg Mn/kg of diet in form of inorganic salts. The formulation of the experimental diets (E1 and E2 differed from C group diet by the replacement of inorganic Fe and Mn salts by organometallic chelates of these elements, at a level of 25% lower than in the premix for group C. As source of inulin, group E1 diet also included 0.5% of dry Jerusalem artichoke, while group E2 diet included 0.5% of a product based on chicory root extract. At the end of the experiment, 6 hens from each group were slaughtered and blood serum and liver samples were collected and assayed for concentration of Fe and Mn. In the final week of the experiment, 18 eggs/group were collected for determination of Fe and Mn concentration in egg yolk. Concentration of measured blood serum parameters (haemoglobin, haematocrit, Fe and Mn in experimental (E groups were lower than in group C, but no significant differences (P>0.05 were registered. Absorption coefficients of Mn had higher values in E groups than in group C, with significant increase (P0.05 between groups were observed for Mn and Fe concentration in egg yolk.

  7. Equivalent Black Carbon measurements and spectral analysis of absorption coefficient during a biomass burning episode in the city of Bogotá, Colombia.

    Quirama, M.; Morales, R.

    2016-12-01

    Light-absorbing carbonaceous aerosol is recognized as a significant short lived climate pollutant that can contribute to direct and indirect radiative forcing. In urban environments, black carbon is an important contributor to the deterioration of local air quality. In this study, we report measurements of equivalent Black Carbon performed during the months of January, February, and March 2016 in the city of Bogotá, Colombia. During this period, a persistent condition of atmospheric stability lead to high concentrations of particulate matter throughout the city. During the month of February, the city was further impacted by a series of small-scale forest fires that took place on hills neighboring the city center. Equivalent Black Carbon (eBC) concentrations were monitored before, during, and after a mayor forest fire episode with a 7-wavelength Aethalometer. The monitoring instruments were located at a traffic impacted site, 18.3 km from the forest fire. To evaluate the contribution of biomass burning to the light-absorbing aerosol particle concentration, spectral analysis of the absorption coefficient of the sampled aerosol particles was performed. When the biomass burning plume directly impacted the monitoring station during the night of February 4, eBC concentrations of up to 40 µg/m3 were observed at nighttime. This concentration was significantly higher than average nighttime concentrations of eBC, observed to be 4 µg/m3 at the site. However, during the period most intensely affected by the biomass burning plume, the angstrom exponent computed between the 450nm and the 970 nm channel, was found to be close to 1. Angstrom exponent close to 1 is an indication that the contribution from traffic generated black carbon is dominant compared to the contribution of biomass burning. The data set collected during this period suggests that despite the significant contribution of the fresh biomass burning plume to the particulate matter concentration in the city, the

  8. Light scattering and extinction measurements combined with laser-induced incandescence for the real-time determination of soot mass absorption cross section.

    Wei, Yiyi; Ma, Lulu; Cao, Tingting; Zhang, Qing; Wu, Jun; Buseck, Peter R; Thompson, J E

    2013-10-01

    An aerosol albedometer was combined with laser-induced incandescence (LII) to achieve simultaneous measurements of aerosol scattering, extinction coefficient, and soot mass concentration. Frequency doubling of a Nd:YAG laser line resulted in a colinear beam of both λ = 532 and 1064 nm. The green beam was used to perform cavity ring-down spectroscopy (CRDS), with simultaneous measurements of scattering coefficient made through use of a reciprocal sphere nephelometer. The 1064 nm beam was selected and directed into a second integrating sphere and used for LII of light-absorbing kerosene lamp soot. Thermal denuder experiments showed the LII signals were not affected by the particle mixing state when laser peak power was 1.5-2.5 MW. The combined measurements of optical properties and soot mass concentration allowed determination of mass absorption cross section (M.A.C., m(2)/g) with 1 min time resolution when soot concentrations were in the low microgram per cubic meter range. Fresh kerosene nanosphere soot (ns-soot) exhibited a mean M.A.C and standard deviation of 9.3 ± 2.7 m(2)/g while limited measurements on dry ambient aerosol yielded an average of 8.2 ± 5.9 m(2)/g when soot was >0.25 μg/m(3). The method also detected increases in M.A.C. values associated with enhanced light absorption when polydisperse, laboratory-generated ns-soot particles were embedded within or coated with ammonium nitrate, ammonium sulfate, and glycerol. Glycerol coatings produced the largest fractional increase in M.A.C. (1.41-fold increase), while solid coatings of ammonium sulfate and ammonium nitrate produced increases of 1.10 and 1.06, respectively. Fresh, ns-soot did not exhibit increased M.A.C. at high relative humidity (RH); however, lab-generated soot coated with ammonium nitrate and held at 85% RH exhibited M.A.C. values nearly double the low-humidity case. The hybrid instrument for simultaneously tracking soot mass concentration and aerosol optical properties in real time is a

  9. Measurement of the mass attenuation coefficients and electron densities for BiPbSrCaCuO superconductor at different energies

    Çevik, U.; Baltaş, H.

    2007-03-01

    The mass attenuation coefficients for Bi, Pb, Sr, Ca, Cu metals, Bi2O3, PbO, SrCO3, CaO, CuO compounds and solid-state forms of Bi1.7Pb0.3Sr2Ca2Cu3O10 superconductor were determined at 57.5, 65.2, 77.1, 87.3, 94.6, 122 and 136 keV energies. The samples were irradiated using a 57Co point source emitted 122 and 136 keV γ-ray energies. The X-ray energies were obtained using secondary targets such as Ta, Bi2O3 and (CH3COO)2UO22H2O. The γ- and X-rays were counted by a Si(Li) detector with a resolution of 0.16 keV at 5.9 keV. The effect of absorption edges on electron density, effective atomic numbers and their variation with photon energy in composite superconductor samples was discussed. Obtained values were compared with theoretical values.

  10. Opto-acoustic measurement of the local light absorption coefficient in turbid media: 1. Monte-Carlo simulation of laser fluence distribution at the beam axis beneath the surface of a turbid medium

    Pelivanov, Ivan M; Barskaya, M I; Podymova, N B; Khokhlova, Tanya D; Karabutov, Aleksander A

    2009-01-01

    A new method for measuring the local light absorption coefficient in turbid media, for example, biological tissues, is proposed. The method is based on the fact that the amplitude of the excited opto-acoustic (OA) signal is proportional to the absorbed laser power density (the product of the light absorption coefficient and the laser fluence) at the medium interface. In the first part of the paper, the influence of the laser beam diameter, the light absorption and reduced scattering coefficients on the maximal amplitude of the laser fluence at the laser beam axis in the near-surface layer of the turbid medium is studied by using the Monte-Carlo simulation. The conditions are predicted under which the amplitude of the OA signal detected in a transparent medium in contact with the scattering medium should remain proportional to the light absorption coefficient of the medium under study, when the scattering coefficient in it changes more than twice. The results of the numerical simulation are used for the theoretical substantiation of the OA method being proposed. (measurement of parametrs of laser radiation)

  11. Apparent directional mass-transfer capacity coefficients in three-dimensional anisotropic heterogeneous aquifers under radial convergent transport

    Pedretti, D.; Fernàndez-Garcia, D.; Sanchez-Vila, X.; Bolster, D.; Benson, D. A.

    2014-02-01

    Aquifer hydraulic properties such as hydraulic conductivity (K) are ubiquitously heterogeneous and typically only a statistical characterization can be sought. Additionally, statistical anisotropy at typical characterization scales is the rule. Thus, regardless of the processes governing solute transport at the local (pore) scale, transport becomes non-Fickian. Mass-transfer models provide an efficient tool that reproduces observed anomalous transport; in some cases though, these models lack predictability as model parameters cannot readily be connected to the physical properties of aquifers. In this study, we focus on a multirate mass-transfer model (MRMT), and in particular the apparent capacity coefficient (β), which is a strong indicator of the potential of immobile zones to capture moving solute. We aim to find if the choice of an apparent β can be phenomenologically related to measures of statistical anisotropy. We analyzed an ensemble of random simulations of three-dimensional log-transformed multi-Gaussian permeability fields with stationary anisotropic correlation under convergent flow conditions. It was found that apparent β also displays an anisotropic behavior, physically controlled by the aquifer directional connectivity, which in turn is controlled by the anisotropic correlation model. A high hydraulic connectivity results in large β values. These results provide new insights into the practical use of mass-transfer models for predictive purposes.

  12. Determination of uranium self-diffusion coefficients in the U O2 nuclear fuel by secondary ion mass spectrometry

    Ferraz, Wilmar Barbosa

    1998-01-01

    This study of uranium self-diffusion in UO 2 presents a great technological interest because its knowledge is necessary to interpret the mechanism of many important processes like, for example, sintering, creep, grain growth, in-reactor densification and others. The present work deals with new measurements of uranium diffusion in UO 2 single crystals and polycrystals through an original mythology based on the utilization of 235 U as tracer and depth profiling by secondary ions mass spectrometry (SIMS). The diffusion experiments were performed between 1498 and 1697 deg C, in H 2 atmosphere. In our experimental conditions, the uranium volume diffusion coefficients measured in UO 2 single crystals can be described by the following Arrhenius relation: D(cm 2 /s) = 8.54x10 -7 exp[-4.4(eV)/K T]. The uranium grain-boundary diffusion experiments performed in UO 2 polycrystals corresponded to the type-B diffusion. In this case, it was possible to determine the product D'δ, where D is the grain-boundary diffusion and is the width of the grain-boundary. In our experimental conditions, the product D'δ can be described by the following relation: D'δ (cm 3 /s) = 1.62x10 -5 exp[-5.6(eV)/K T]. These results that the uranium volume diffusion coefficients, measured in UO 2 single crystals, are 5 orders of magnitude lower than the uranium grain boundary diffusion coefficients measured in UO 2 polycrystalline pellets, in the same experimental conditions. This large difference between these two types of diffusivities indicates that the grain boundary is a preferential via for uranium diffusion in UO 2 polycrystalline pellet. (author)

  13. Mass attenuation coefficients, effective atomic and electron numbers of stainless steel and carbon steels with different energies

    Mohd Fakarudin Abdul Rahman; Mohd Iqbal Saripan; Nor Paiza Mohamad Hasan; Ismail Mustapha

    2011-01-01

    The total mass attenuation coefficients (μ/ ρ) of stainless steel (SS316L) and carbon steel (A516) that are widely used as petrochemical plant components, such as distillation column, heat exchanger, boiler and storage tank were measured at 662, 1073 and 1332 keV of photon energies. Measurements of radiation intensity for various thicknesses of steel were made by using transmission method. The γ-ray intensity were counted by using a Gamma spectrometer that contains a Hyper-pure Germanium (HPGe) detector connected with Multi Channel Analyzer (MCA). The effective numbers of atomic (Z eff ) and electron (N eff ) obtained experimentally were compared by those obtained through theoretical calculation. Both experimental and calculated values of Z eff and N eff were in good agreement. (author)

  14. Anomalous phosphine sensitivity coefficients as probes for a possible variation of the proton-to-electron mass ratio

    Owens, A.; Yurchenko, S. N.; Špirko, V.

    2018-02-01

    A robust variational approach is used to investigate the sensitivity of the rotation-vibration spectrum of phosphine (PH3) to a possible cosmological variation of the proton-to-electron mass ratio, μ. Whilst the majority of computed sensitivity coefficients, T, involving the low-lying vibrational states acquire the expected values of T ≈ -1 and T ≈ -1/2 for rotational and ro-vibrational transitions, respectively, anomalous sensitivities are uncovered for the A1 - A2 splittings in the ν2/ν4, ν1/ν3 and 2ν _4^{ℓ=0}/2ν _4^{ℓ=2} manifolds of PH3. A pronounced Coriolis interaction between these states in conjunction with accidentally degenerate A1 and A2 energy levels produces a series of enhanced sensitivity coefficients. Phosphine is expected to occur in a number of different astrophysical environments and has potential for investigating a drifting constant. Furthermore, the displayed behaviour hints at a wider trend in molecules of C_{3v}(M) symmetry, thus demonstrating that the splittings induced by higher-order ro-vibrational interactions are well suited for probing μ in other symmetric top molecules in space, since these low-frequency transitions can be straightforwardly detected by radio telescopes.

  15. Silicon oxide particle formation in RF plasmas investigated by infrared absorption spectroscopy and mass spectrometry

    Hollenstein, Ch.; Howling, A.A.; Courteille, C.; Magni, D.; Scholz, S.M.; Kroesen, G.M.W.; Simons, N.; de Zeeuw, W.; Schwarzenbach, W.

    1998-01-01

    In situ Fourier transform infrared absorption spectroscopy has been used to study the composition of particles formed and suspended in radio-frequency discharges of silane - oxygen-argon gas mixtures. The silane gas consumption was observed by infrared absorption. The stoichiometry of the produced

  16. MAGIICAT III. Interpreting self-similarity of the circumgalactic medium with virial mass using Mg II absorption

    Churchill, Christopher W.; Trujillo-Gomez, Sebastian; Nielsen, Nikole M.; Kacprzak, Glenn G.

    2013-01-01

    In Churchill et al., we used halo abundance matching applied to 182 galaxies in the Mg II Absorber-Galaxy Catalog (MAGIICAT) and showed that the mean Mg II λ2796 equivalent width follows a tight inverse-square power law, W r (2796)∝(D/R vir ) –2 , with projected location relative to the galaxy virial radius and that the Mg II absorption covering fraction is effectively invariant with galaxy virial mass, M h , over the range 10.7 ≤ log M h /M ☉ ≤ 13.9. In this work, we explore multivariate relationships between W r (2796), virial mass, impact parameter, virial radius, and the theoretical cooling radius that further elucidate self-similarity in the cool/warm (T = 10 4 -10 4.5 K) circumgalactic medium (CGM) with virial mass. We show that virial mass determines the extent and strength of the Mg II absorbing gas such that the mean W r (2796) increases with virial mass at fixed distance while decreasing with galactocentric distance for fixed virial mass. The majority of the absorbing gas resides within D ≅ 0.3 R vir , independent of both virial mass and minimum absorption threshold; inside this region, and perhaps also in the region 0.3 < D/R vir ≤ 1, the mean W r (2796) is independent of virial mass. Contrary to absorber-galaxy cross-correlation studies, we show there is no anti-correlation between W r (2796) and virial mass. We discuss how simulations and theory constrained by observations support self-similarity of the cool/warm CGM via the physics governing star formation, gas-phase metal enrichment, recycling efficiency of galactic scale winds, filament and merger accretion, and overdensity of local environment as a function of virial mass.

  17. MAGIICAT III. Interpreting self-similarity of the circumgalactic medium with virial mass using Mg II absorption

    Churchill, Christopher W.; Trujillo-Gomez, Sebastian; Nielsen, Nikole M. [New Mexico State University, Las Cruces, NM 88003 (United States); Kacprzak, Glenn G. [Swinburne University of Technology, Victoria 3122 (Australia)

    2013-12-10

    In Churchill et al., we used halo abundance matching applied to 182 galaxies in the Mg II Absorber-Galaxy Catalog (MAGIICAT) and showed that the mean Mg II λ2796 equivalent width follows a tight inverse-square power law, W{sub r} (2796)∝(D/R {sub vir}){sup –2}, with projected location relative to the galaxy virial radius and that the Mg II absorption covering fraction is effectively invariant with galaxy virial mass, M {sub h}, over the range 10.7 ≤ log M {sub h}/M {sub ☉} ≤ 13.9. In this work, we explore multivariate relationships between W{sub r} (2796), virial mass, impact parameter, virial radius, and the theoretical cooling radius that further elucidate self-similarity in the cool/warm (T = 10{sup 4}-10{sup 4.5} K) circumgalactic medium (CGM) with virial mass. We show that virial mass determines the extent and strength of the Mg II absorbing gas such that the mean W{sub r} (2796) increases with virial mass at fixed distance while decreasing with galactocentric distance for fixed virial mass. The majority of the absorbing gas resides within D ≅ 0.3 R {sub vir}, independent of both virial mass and minimum absorption threshold; inside this region, and perhaps also in the region 0.3 < D/R {sub vir} ≤ 1, the mean W{sub r} (2796) is independent of virial mass. Contrary to absorber-galaxy cross-correlation studies, we show there is no anti-correlation between W{sub r} (2796) and virial mass. We discuss how simulations and theory constrained by observations support self-similarity of the cool/warm CGM via the physics governing star formation, gas-phase metal enrichment, recycling efficiency of galactic scale winds, filament and merger accretion, and overdensity of local environment as a function of virial mass.

  18. Apparent Diffusion Coefficient Maps of Pediatric Mass Lesions with Free-Breathing Diffusion-Weighted Magnetic Resonance: Feasibility Study

    Olsen, Oe.E.; Sebire, N.J.

    2006-01-01

    Purpose: To assess the technical feasibility of apparent diffusion coefficient (ADC) mapping based on free-breathing diffusion-weighted magnetic resonance (DW-MR) outside the CNS in children. Material and Methods: Twelve children with mass lesions of varied histopathology were scanned with short-tau inversion recovery (STIR), contrast-enhanced T1-weighted (CE-T1W), and diffusion-weighted (b = 0, 500 and 1,000 s/mm 2 ) sequences. ADC maps were calculated. Lesion-to-background signal intensity ratios were measured and compared between STIR/CE-T1W/ADC overall (Friedman test) and between viable embryonal tumors and other lesions (Kruskal-Wallis test). Results: ADC maps clearly depicted all lesions. Lesion-to-background signal intensity ratios of STIR (median 3.7), CE-T1W (median 1.4), and ADC (median 1.6) showed no overall difference (chi-square = 3.846; P = 0.146), and there was no difference between viable embryonal tumors and other lesions within STIR/CE-T1W/ADC (chi-square 1.118/0.669/<0.001; P = 0.290/0.414/1.000, respectively). Conclusion: ADC mapping is feasible in free-breathing imaging of pediatric mass lesions outside the CNS using standard clinical equipment. Keywords: Diffusion-weighted magnetic resonance imaging; infants and children; neoplasms

  19. Migration of antioxidants from polylactic acid films, a parameter estimation approach: Part I - A model including convective mass transfer coefficient.

    Samsudin, Hayati; Auras, Rafael; Burgess, Gary; Dolan, Kirk; Soto-Valdez, Herlinda

    2018-03-01

    A two-step solution based on the boundary conditions of Crank's equations for mass transfer in a film was developed. Three driving factors, the diffusion (D), partition (K p,f ) and convective mass transfer coefficients (h), govern the sorption and/or desorption kinetics of migrants from polymer films. These three parameters were simultaneously estimated. They provide in-depth insight into the physics of a migration process. The first step was used to find the combination of D, K p,f and h that minimized the sums of squared errors (SSE) between the predicted and actual results. In step 2, an ordinary least square (OLS) estimation was performed by using the proposed analytical solution containing D, K p,f and h. Three selected migration studies of PLA/antioxidant-based films were used to demonstrate the use of this two-step solution. Additional parameter estimation approaches such as sequential and bootstrap were also performed to acquire a better knowledge about the kinetics of migration. The proposed model successfully provided the initial guesses for D, K p,f and h. The h value was determined without performing a specific experiment for it. By determining h together with D, under or overestimation issues pertaining to a migration process can be avoided since these two parameters are correlated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Gamma-ray mass attenuation coefficient and half value layer factor of some oxide glass shielding materials

    Waly, El-Sayed A.; Fusco, Michael A.; Bourham, Mohamed A.

    2016-01-01

    The variation in dosimetric parameters such as mass attenuation coefficient, half value layer factor, exposure buildup factor, and the photon mean free path for different oxide glasses for the incident gamma energy range 0.015–15 MeV has been studied using MicroShield code. It has been inferred that the addition of PbO and Bi 2 O 3 improves the gamma ray shielding properties. Thus, the effect of chemical composition on these parameters is investigated in the form of six different glass compositions, which are compared with specialty concrete for nuclear radiation shielding. The composition termed ‘Glass 6’ in this paper has the highest mass attenuation and the smallest half value layer and may have potential applications in radiation shielding. An example dry storage cask utilizing an additional layer of Glass 6 as an intermediate shielding layer, simulated in MicroShield, is capable of reducing the exposure rate at the cask surface by over 20 orders of magnitude compared to the case without a glass layer. Based on this study, Glass 6 shows promise as a gamma-ray shielding material, particularly for dry cask storage.

  1. The Role of Apparent Diffusion Coefficient Quantification in Differentiating Benign and Malignant Renal Masses by 3 Tesla Magnetic Resonance Imaging.

    Göya, Cemil; Hamidi, Cihad; Bozkurt, Yaşar; Yavuz, Alpaslan; Kuday, Suzan; Gümüş, Hatice; Türkçü, Gül; Hattapoğlu, Salih; Bilici, Aslan

    2015-07-01

    Diffusion-weighted magnetic resonance imaging (DWI) is a widely-accepted diagnostic modality whose efficacy has been investigated by numerous past studies in the differentiation of malignant lesions from benign entities. The aim of this study was to evaluate the efficiency of diffusion-weighted magnetic resonance imaging in the characterization of renal lesions. Diagnostic accuracy study. A total of 137 patients with renal lesions were included in this study. The median apparent diffusion coefficient (ADC) values as well as the b 800 and b 1600 signal intensities of normal kidneys, solid components of mixed renal masses, and total cystic lesions were evaluated. There were significant differences between the ADC values of lesions and normal renal parenchyma, and between the ADC values of benign and malignant renal lesions on DWIs at b values of 800 and 1600 s/mm(2) (pbenign and malignant renal lesions. A cutoff value of 1.623 × 10(-3) mm(2)/s for the ADC with a b value of 1600 s/mm(2) provided 79% sensitivity and 96% specificity (pbenign and malignant renal lesions. Accurate assessment of renal masses is important for determining the necessity for surgical intervention. DWI provides additional value by differentiating benign from malignant renal tumors and can be added to routine kidney MRI protocols.

  2. Energy absorption during impact on the proximal femur is affected by body mass index and flooring surface.

    Bhan, Shivam; Levine, Iris C; Laing, Andrew C

    2014-07-18

    Impact mechanics theory suggests that peak loads should decrease with increase in system energy absorption. In light of the reduced hip fracture risk for persons with high body mass index (BMI) and for falls on soft surfaces, the purpose of this study was to characterize the effects of participant BMI, gender, and flooring surface on system energy absorption during lateral falls on the hip with human volunteers. Twenty university-aged participants completed the study with five men and five women in both low BMI (27.5 kg/m(2)) groups. Participants underwent lateral pelvis release experiments from a height of 5 cm onto two common floors and four safety floors mounted on a force plate. A motion-capture system measured pelvic deflection. The energy absorbed during the initial compressive phase of impact was calculated as the area under the force-deflection curve. System energy absorption was (on average) 3-fold greater for high compared to low BMI participants, but no effects of gender were observed. Even after normalizing for body mass, high BMI participants absorbed 1.8-fold more energy per unit mass. Additionally, three of four safety floors demonstrated significantly increased energy absorption compared to a baseline resilient-rolled-sheeting system (% increases ranging from 20.7 to 28.3). Peak system deflection was larger for high BMI persons and for impacts on several safety floors. This study indicates that energy absorption may be a common mechanism underlying the reduced risk of hip fracture for persons with high BMI and for those who fall on soft surfaces. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  3. Absorption column working study for iodine formed in spent fuel reprocessing plant gaseous effluents: hydrodynamic and mass transfer

    Vignau, B.

    1986-09-01

    The hydrodynamic and matter transfer parameters has been studied on absorption columns destined to trap iodine issued of spent fuel reprocessing plants. These columns have different packing - Raschig rings (glass, ceramic, PVC, steel) - Berl saddles (ceramic) - Weaved metallic thread (steel). The effect of dimension and of packing structure on gas pressure drop and on liquid holdup has been evaluated. The partial transfer coefficients of I 2 -Air-NaOH system has been the object of an experimental study. This system can be simulated by CO 2 -Air-NaOH system [fr

  4. Estimating absorption coefficients of colored dissolved organic matter (CDOM) using a semi-analytical algorithm for Southern Beaufort Sea (Canadian Arctic) waters: application to deriving concentrations of dissolved organic carbon from space

    Matsuoka, A.; Hooker, S. B.; Bricaud, A.; Gentili, B.; Babin, M.

    2012-10-01

    A series of papers have suggested that freshwater discharge, including a large amount of dissolved organic matter (DOM), has increased since the middle of the 20th century. In this study, a semi-analytical algorithm for estimating light absorption coefficients of the colored fraction of DOM (CDOM) was developed for Southern Beaufort Sea waters using remote sensing reflectance at six wavelengths in the visible spectral domain corresponding to MODIS ocean color sensor. This algorithm allows to separate colored detrital matter (CDM) into CDOM and non-algal particles (NAP) by determining NAP absorption using an empirical relationship between NAP absorption and particle backscattering coefficients. Evaluation using independent datasets, that were not used for developing the algorithm, showed that CDOM absorption can be estimated accurately to within an uncertainty of 35% and 50% for oceanic and turbid waters, respectively. In situ measurements showed that dissolved organic carbon (DOC) concentrations were tightly correlated with CDOM absorption (r2 = 0.97). By combining the CDOM absorption algorithm together with the DOC versus CDOM relationship, it is now possible to estimate DOC concentrations in the near-surface layer of the Southern Beaufort Sea using satellite ocean color data. DOC concentrations in the surface waters were estimated using MODIS ocean color data, and the estimates showed reasonable values compared to in situ measurements. We propose a routine and near real-time method for deriving DOC concentrations from space, which may open the way to an estimate of DOC budgets for Arctic coastal waters.

  5. Hyperfine structure of 147,149Sm measured using saturated absorption spectroscopy in combination with resonance-ionization mass spectroscopy

    Park, Hyunmin; Lee, Miran; Rhee, Yongjoo

    2003-01-01

    The hyperfine structures of four levels of the Sm isotopes have been measured by means of diode-laser-based Doppler-free saturated absorption spectroscopy in combination with a diode-laser-initiated resonance-ionization mass spectroscopy. It was demonstrated that combining the two spectroscopic methods was very effective for the identification and accurate measurement of the spectral lines of atoms with several isotopes, such as the rare-earth elements. From the obtained spectra, the hyperfine constants A and B for the odd-mass isotopes 147 Sm and 149 Sm were determined for four upper levels of the studied transitions.

  6. A convenient method for calculation of ionic diffusion coefficients for accurate selected ion flow tube mass spectrometry, SIFT-MS

    Dryahina, K.; Spanel, P.

    2005-07-01

    A method to calculate diffusion coefficients of ions important for the selected ion flow tube mass spectrometry, SIFT-MS, is presented. The ions, on which this method is demonstrated, include the SIFT-MS precursors H3O+(H2O)0,1,2,3, NO.+(H2O)0,1,2 and O2+ and the product ions relevant to analysis of breath trace metabolites ammonia (NH3+(H2O)0,1,2, NH4+(H2O)0,1,2), acetaldehyde (C2H4OH+(H2O)0,1,2), acetone (CH3CO+, (CH3)2CO+, (CH3)2COH+(H2O)0,1, (CH3)2CO.NO+), ethanol (C2H5OHH+(H2O)0,1,2) and isoprene (C5H7+, C5H8+, C5H9+). Theoretical model of the (12, 4) potential for interaction between the ions and the helium atoms is used, with the repulsive part approximated by the mean hard-sphere cross section and the attractive part describing ion-induced dipole interactions. The reduced zero-field mobilities at 300 K are calculated using the Viehland and Mason theory [L.A. Viehland, S.L. Lin, E.A. Mason, At. Data Nucl. Data Tables, 60 (1995) 37-95], parameterised by a simple formula as a function of the mean hard-sphere cross section, and converted to diffusion coefficients using the Einstein relation. The method is tested on a set of experimental data for simple ions and cluster ions.

  7. Effects of micro-sized and nano-sized WO_3 on mass attenauation coefficients of concrete by using MCNPX code

    Tekin, H.O.; Singh, V.P.; Manici, T.

    2017-01-01

    In the present work the effect of tungsten oxide (WO_3) nanoparticles on mass attenauation coefficients of concrete has been investigated by using MCNPX (version 2.4.0). The validation of generated MCNPX simulation geometry has been provided by comparing the results with standard XCOM data for mass attenuation coefficients of concrete. A very good agreement between XCOM and MCNPX have been obtained. The validated geometry has been used for definition of nano-WO_3 and micro-WO_3 into concrete sample. The mass attenuation coefficients of pure concrete and WO_3 added concrete with micro-sized and nano-sized have been compared. It was observed that shielding properties of concrete doped with WO_3 increased. The results of mass attenauation coefficients also showed that the concrete doped with nano-WO_3 significanlty improve shielding properties than micro-WO_3. It can be concluded that addition of nano-sized particles can be considered as another mechanism to reduce radiation dose. - Highlights: • It was found that size of the WO_3 affected the mass attenuation coefficients of concrete in all photon energies.

  8. Spectral- and size-resolved mass absorption efficiency of mineral dust aerosols in the shortwave spectrum: a simulation chamber study

    L. Caponi

    2017-06-01

    Full Text Available This paper presents new laboratory measurements of the mass absorption efficiency (MAE between 375 and 850 nm for 12 individual samples of mineral dust from different source areas worldwide and in two size classes: PM10. 6 (mass fraction of particles of aerodynamic diameter lower than 10.6 µm and PM2. 5 (mass fraction of particles of aerodynamic diameter lower than 2.5 µm. The experiments were performed in the CESAM simulation chamber using mineral dust generated from natural parent soils and included optical and gravimetric analyses. The results show that the MAE values are lower for the PM10. 6 mass fraction (range 37–135  ×  10−3 m2 g−1 at 375 nm than for the PM2. 5 (range 95–711  ×  10−3 m2 g−1 at 375 nm and decrease with increasing wavelength as λ−AAE, where the Ångström absorption exponent (AAE averages between 3.3 and 3.5, regardless of size. The size independence of AAE suggests that, for a given size distribution, the dust composition did not vary with size for this set of samples. Because of its high atmospheric concentration, light absorption by mineral dust can be competitive with black and brown carbon even during atmospheric transport over heavy polluted regions, when dust concentrations are significantly lower than at emission. The AAE values of mineral dust are higher than for black carbon (∼ 1 but in the same range as light-absorbing organic (brown carbon. As a result, depending on the environment, there can be some ambiguity in apportioning the aerosol absorption optical depth (AAOD based on spectral dependence, which is relevant to the development of remote sensing of light-absorbing aerosols and their assimilation in climate models. We suggest that the sample-to-sample variability in our dataset of MAE values is related to regional differences in the mineralogical composition of the parent soils. Particularly in the PM2. 5 fraction, we found a strong

  9. Spectral- and size-resolved mass absorption efficiency of mineral dust aerosols in the shortwave spectrum: a simulation chamber study

    Caponi, Lorenzo; Formenti, Paola; Massabó, Dario; Di Biagio, Claudia; Cazaunau, Mathieu; Pangui, Edouard; Chevaillier, Servanne; Landrot, Gautier; Andreae, Meinrat O.; Kandler, Konrad; Piketh, Stuart; Saeed, Thuraya; Seibert, Dave; Williams, Earle; Balkanski, Yves; Prati, Paolo; Doussin, Jean-François

    2017-06-01

    This paper presents new laboratory measurements of the mass absorption efficiency (MAE) between 375 and 850 nm for 12 individual samples of mineral dust from different source areas worldwide and in two size classes: PM10. 6 (mass fraction of particles of aerodynamic diameter lower than 10.6 µm) and PM2. 5 (mass fraction of particles of aerodynamic diameter lower than 2.5 µm). The experiments were performed in the CESAM simulation chamber using mineral dust generated from natural parent soils and included optical and gravimetric analyses. The results show that the MAE values are lower for the PM10. 6 mass fraction (range 37-135 × 10-3 m2 g-1 at 375 nm) than for the PM2. 5 (range 95-711 × 10-3 m2 g-1 at 375 nm) and decrease with increasing wavelength as λ-AAE, where the Ångström absorption exponent (AAE) averages between 3.3 and 3.5, regardless of size. The size independence of AAE suggests that, for a given size distribution, the dust composition did not vary with size for this set of samples. Because of its high atmospheric concentration, light absorption by mineral dust can be competitive with black and brown carbon even during atmospheric transport over heavy polluted regions, when dust concentrations are significantly lower than at emission. The AAE values of mineral dust are higher than for black carbon (˜ 1) but in the same range as light-absorbing organic (brown) carbon. As a result, depending on the environment, there can be some ambiguity in apportioning the aerosol absorption optical depth (AAOD) based on spectral dependence, which is relevant to the development of remote sensing of light-absorbing aerosols and their assimilation in climate models. We suggest that the sample-to-sample variability in our dataset of MAE values is related to regional differences in the mineralogical composition of the parent soils. Particularly in the PM2. 5 fraction, we found a strong linear correlation between the dust light-absorption properties and elemental

  10. Performance evaluation and mass transfer study of CO2 absorption in flat sheet membrane contactor using novel porous polysulfone membrane

    Nabian, Nima; Ghoreyshi, Ali Asghar; Rahimpour, Ahmad; Shakeri, Mohsen

    2015-01-01

    The performance of gas-liquid membrane contactor for CO 2 capture was investigated using a novel polysulfone (PSF) flat membrane prepared via non-solvent phase inversion method. Polyvinyl pyrrolidone (PVP) was used as an additive in the dope solution of PSF membranes. Morphological studies by scanning electron microscopy (SEM) analysis revealed that PSF membrane with PVP has a finger-like structure, but the PSF membrane without PVP has a sponge-like structure. Also, characterization results through atomic force microscopy (AFM) and contact angle measurement demonstrated that the porosity, surface roughness and hydrophobicity of the PSF membrane increased with addition of PVP to the dope solution. Mass transfer resistance analysis, based on CO 2 absorption flux, displayed that addition of PVP to the dope solution of PSF membrane decreased membrane mass transfer resistance, and significantly improved CO 2 absorption flux up to 2.7 and 1.8 times of absorption fluxes of PSF membrane without PVP and commercial PVDF, respectively.

  11. Bio-mass stimulated absorption refrigerator for food storage in Papua New Guinea

    Uppal, A.H.; Komuna, K.K. (University of Technology, Papua (New Guinea). Dept. of Mechanical Engineering)

    1992-01-01

    A medium capacity (140 litre) water-ammonia absorption refrigerator, thermally stimulated by a charcoal-stove is being developed to store food in remote locations and island communities of Papua New Guinea. The paper describes a prototype charcoal or biomass-stove thermal refrigerator in which the absorption cycle and thermo-syphonic cycle of a heating liquid has been coupled in a novel and straight forward approach. The system consisted of a heat-exchanger, in the form of a jacket surrounding the generator tube of a water-ammonia absorption cycle refrigerator, and was connected in a close-pipe work loop to a heat exchanger placed in a charcoal-stove. A heat-transfer oil flowed due to thermo-syphonic forces between the heat exchanger and the jacket. According to initial tests it took 4 hours for the system to warm up, and took another 7 hours for water in the freezer cabinet to approach 0{sup o}C from an initial 25{sup o}C. The cooling capacity of the evaporator was roughly 70% of the cooling capacity of the original system with electric heating. For a twelve hour test the stove consumed 2.5 kg of charcoal with an air port opening between 3 to 5 millimeters. Preliminary estimates indicate that the described prototype absorption unit stimulated by the wood/coconut husk stove (rather than electricity/kerosene), when manufactured commercially will cost less than US 1500 dollars at 1991 prices. (Author).

  12. Isospin and the proton-absorptive-potential anomaly near mass 100

    Flynn, D.S.; Hershberger, R.L.; Gabbard, F.

    1982-01-01

    An isospin coupled-channels analysis of sub-Coulomb-proton-absorption cross sections has been performed for /sup 92,94,96/Zr and /sup 94,96,98,100/Mo. Introduction of coupling to the nA channel is shown to shift and damp the single-particle resonances, in addition to giving rise to isobaric-analog resonances. In spite of these effects due to the coupling, large variations in the absorptive potentials were still required to fit measured (p,n) cross sections. 96 Zr(p,n) and 100 Mo(p,n) cross sections were measured and analyzed with a standard optical model for this work. Other Zr(p,n) and Mo(p,n) cross sections were taken from previous results

  13. Towards a quantitative, measurement-based estimate of the uncertainty in photon mass attenuation coefficients at radiation therapy energies

    Ali, E. S. M.; Spencer, B.; McEwen, M. R.; Rogers, D. W. O.

    2015-02-01

    In this study, a quantitative estimate is derived for the uncertainty in the XCOM photon mass attenuation coefficients in the energy range of interest to external beam radiation therapy—i.e. 100 keV (orthovoltage) to 25 MeV—using direct comparisons of experimental data against Monte Carlo models and theoretical XCOM data. Two independent datasets are used. The first dataset is from our recent transmission measurements and the corresponding EGSnrc calculations (Ali et al 2012 Med. Phys. 39 5990-6003) for 10-30 MV photon beams from the research linac at the National Research Council Canada. The attenuators are graphite and lead, with a total of 140 data points and an experimental uncertainty of ˜0.5% (k = 1). An optimum energy-independent cross section scaling factor that minimizes the discrepancies between measurements and calculations is used to deduce cross section uncertainty. The second dataset is from the aggregate of cross section measurements in the literature for graphite and lead (49 experiments, 288 data points). The dataset is compared to the sum of the XCOM data plus the IAEA photonuclear data. Again, an optimum energy-independent cross section scaling factor is used to deduce the cross section uncertainty. Using the average result from the two datasets, the energy-independent cross section uncertainty estimate is 0.5% (68% confidence) and 0.7% (95% confidence). The potential for energy-dependent errors is discussed. Photon cross section uncertainty is shown to be smaller than the current qualitative ‘envelope of uncertainty’ of the order of 1-2%, as given by Hubbell (1999 Phys. Med. Biol 44 R1-22).

  14. Gas–Liquid Mass Transfer Coefficient in Stirred Tanks Interpreted through Models of Idealized Eddy Structure of Turbulence in the Bubble Vicinity

    Linek, V.; Kordač, M.; Zedníková, Mária; Moucha, T.

    2004-01-01

    Roč. 43, č. 12 (2004), s. 1511-1517 ISSN 0255-2701 Institutional research plan: CEZ:AV0Z4072921 Keywords : mass transfer coefficient * bubble * dynamic pressure method Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.033, year: 2004

  15. Influence of liquid viscosity and surface tension on the gas-liquid mass transfer coefficient for solid foam packings in co-current two-phase flow

    Stemmet, C.P.; Bartelds, F.; Schaaf, van der J.; Kuster, B.F.M.; Schouten, J.C.

    2008-01-01

    The gas–liquid mass transfer coefficient and other hydrodynamic parameters such as liquid holdup and frictional pressure drop are presented for gas and liquid moving in co-current upflow and downflow through solid foam packings of 10 and of 40 pores per linear inch (ppi). The effect of increasing

  16. Henry’s Law Constant and Overall Mass Transfer Coefficient for Formaldehyde Emission from Small Water Pools under Simulated Indoor Environmental Conditions

    The Henry’s law constant (HLC) and the overall mass transfer coefficient are both important parameters for modeling formaldehyde emissions from aqueous solutions. In this work, the apparent HLCs for aqueous formaldehyde solutions were determined in the concentration range from 0....

  17. A novel inverse numerical modeling method for the estimation of water and salt mass transfer coefficients during ultrasonic assisted-osmotic dehydration of cucumber cubes.

    Kiani, Hosein; Karimi, Farzaneh; Labbafi, Mohsen; Fathi, Morteza

    2018-06-01

    The objective of this paper was to study the moisture and salt diffusivity during ultrasonic assisted-osmotic dehydration of cucumbers. Experimental measurements of moisture and salt concentration versus time were carried out and an inverse numerical method was performed by coupling a CFD package (OpenFOAM) with a parameter estimation software (DAKOTA) to determine mass transfer coefficients. A good agreement between experimental and numerical results was observed. Mass transfer coefficients were from 3.5 × 10 -9 to 7 × 10 -9  m/s for water and from 4.8 × 10 -9  m/s to 7.4 × 10 -9  m/s for salt at different conditions (diffusion coefficients of around 3.5 × 10 -12 -11.5 × 10 -12  m 2 /s for water and 5 × 10 -12  m/s-12 × 10 -12  m 2 /s for salt). Ultrasound irradiation could increase the mass transfer coefficient. The values obtained by this method were closer to the actual data. The inverse simulation method can be an accurate technique to study the mass transfer phenomena during food processing. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Estimating absorption coefficients of colored dissolved organic matter (CDOM) using a semi-analytical algorithm for southern Beaufort Sea waters: application to deriving concentrations of dissolved organic carbon from space

    Matsuoka, A.; Hooker, S. B.; Bricaud, A.; Gentili, B.; Babin, M.

    2013-02-01

    A series of papers have suggested that freshwater discharge, including a large amount of dissolved organic matter (DOM), has increased since the middle of the 20th century. In this study, a semi-analytical algorithm for estimating light absorption coefficients of the colored fraction of DOM (CDOM) was developed for southern Beaufort Sea waters using remote sensing reflectance at six wavelengths in the visible spectral domain corresponding to MODIS ocean color sensor. This algorithm allows the separation of colored detrital matter (CDM) into CDOM and non-algal particles (NAP) through the determination of NAP absorption using an empirical relationship between NAP absorption and particle backscattering coefficients. Evaluation using independent datasets, which were not used for developing the algorithm, showed that CDOM absorption can be estimated accurately to within an uncertainty of 35% and 50% for oceanic and coastal waters, respectively. A previous paper (Matsuoka et al., 2012) showed that dissolved organic carbon (DOC) concentrations were tightly correlated with CDOM absorption in our study area (r2 = 0.97). By combining the CDOM absorption algorithm together with the DOC versus CDOM relationship, it is now possible to estimate DOC concentrations in the near-surface layer of the southern Beaufort Sea using satellite ocean color data. DOC concentrations in the surface waters were estimated using MODIS ocean color data, and the estimates showed reasonable values compared to in situ measurements. We propose a routine and near real-time method for deriving DOC concentrations from space, which may open the way to an estimate of DOC budgets for Arctic coastal waters.

  19. Estimating absorption coefficients of colored dissolved organic matter (CDOM using a semi-analytical algorithm for southern Beaufort Sea waters: application to deriving concentrations of dissolved organic carbon from space

    A. Matsuoka

    2013-02-01

    Full Text Available A series of papers have suggested that freshwater discharge, including a large amount of dissolved organic matter (DOM, has increased since the middle of the 20th century. In this study, a semi-analytical algorithm for estimating light absorption coefficients of the colored fraction of DOM (CDOM was developed for southern Beaufort Sea waters using remote sensing reflectance at six wavelengths in the visible spectral domain corresponding to MODIS ocean color sensor. This algorithm allows the separation of colored detrital matter (CDM into CDOM and non-algal particles (NAP through the determination of NAP absorption using an empirical relationship between NAP absorption and particle backscattering coefficients. Evaluation using independent datasets, which were not used for developing the algorithm, showed that CDOM absorption can be estimated accurately to within an uncertainty of 35% and 50% for oceanic and coastal waters, respectively. A previous paper (Matsuoka et al., 2012 showed that dissolved organic carbon (DOC concentrations were tightly correlated with CDOM absorption in our study area (r2 = 0.97. By combining the CDOM absorption algorithm together with the DOC versus CDOM relationship, it is now possible to estimate DOC concentrations in the near-surface layer of the southern Beaufort Sea using satellite ocean color data. DOC concentrations in the surface waters were estimated using MODIS ocean color data, and the estimates showed reasonable values compared to in situ measurements. We propose a routine and near real-time method for deriving DOC concentrations from space, which may open the way to an estimate of DOC budgets for Arctic coastal waters.

  20. Errors in instumental neutron activation analysis caused by matrix absorption

    Croudace, I.W.

    1979-01-01

    Instrumental neutron activation analysis of the geochemically important rare earth elements, together with Ta, Hf and U involves energies below 150 keV where absorption of radiation by the sample becomes inceasingly important. Determinations of the total mass absorption coefficients have been made. (C.F.)

  1. In Situ Measurements of Aerosol Mass Concentration and Spectral Absorption at Three Location in and Around Mexico City

    Chaudhry, Z.; Martins, V.; Li, Z.

    2006-12-01

    As a result of population growth and increasing industrialization, air pollution in heavily populated urban areas is one of the central environmental problems of the century. As a part of the MILAGRO (Megacity Initiative: Local and Global Research Observations) study, Nuclepore filters were collected in two size ranges (PM10 and PM2.5) at 12 hour intervals at three location in Mexico during March, 2006. Sampling stations were located at the Instituto Mexicano del Petroleo (T0), at the Rancho La Bisnago in the State of Hidalgo (T2) and along the Gulf Coast in Tampico (Tam). Each filter was analyzed for mass concentration, aerosol scattering and absorption efficiencies. Mass concentrations at T0 ranged from 47 to 179 μg/m3 for PM10 with an average concentration of 96 μg/m3, and from 20 to 93 μg/m3 for PM2.5 with an average concentration of 41 μg/m3. Mass concentrations at T2 ranged from 12 to 154 μg/m3 for PM10 with an average concentration of 51 μg/m3, and from 7 to 50 μg/m3 for PM2.5 with an average concentration of 25 μg/m3. Mass concentrations at Tam ranged from 34 to 80 μg/m3 for PM10 with an average concentration of 52 μg/m3, and from 8 to 23 μg/m3 for PM2.5 with an average concentration of 13 μg/m3. While some of the extreme values are likely linked to local emissions, regional air pollution episodes also played important roles. Each of the sampling stations experienced a unique atmospheric condition. The site at T0 was influenced by urban air pollution and dust storms, the site at T2 was significantly less affected by air pollution but more affected by regional dust storms and local dust devils while Tam was influenced by air pollution, dust storms and the natural marine environment. The spectral mass absorption efficiency was measured from 350 to 2500 nm and shows large differences between the absorption properties of soil dust, black carbon, and organic aerosols. The strong spectral differences observed can be related to differences in

  2. Pressure shift coefficient measurements in an RF discharge for Ar 4s[3/2]2—5p[3/2]3 transition with the help of diodelaser absorption spectroscopy

    Chernyshov, A. K.; Mikheyev, P. A.; Lunev, N. N.; Azyazov, V. N.

    2018-04-01

    Optically pumped all-rare-gas laser (OPRGL) with unique properties were recently proposed with a possibility to obtain the laser power on the order of hundreds of Watts from a cubic centimeter. To provide high laser efficiency, the pumping radiation has to match the absorption spectrum of the rare gas metastables. To meet this condition a reliable diagnostics of the key parameters of the active medium is required and knowledge of the broadening and shift coefficients for corresponding transitions of rare gases is necessary. In this paper, the diode-laser absorption spectroscopy was employed to determine the pressure shift coefficient for 811.5 nm Ar line. The value of obtained coefficient in pure argon reduced to 300 K is -(2.1 ± 0.1) × 10-10 s-1cm3. In the course of the study the pressure broadening coefficient was also evaluated and found to be (2.4 ± 0.5) × 10-10 s-1cm3.

  3. On the Bias in the Danckwerts’ Plot Method for the Determination of the Gas–Liquid Mass-Transfer Coefficient and Interfacial Area

    German E. Cortes Garcia

    2018-02-01

    Full Text Available The Danckwerts’ plot method is a commonly used graphical technique to independently determine the interfacial area and mass-transfer coefficient in gas–liquid contactors. The method was derived in 1963 when computational capabilities were limited and intensified process equipment did not exist. A numerical analysis of the underlying assumptions of the method in this paper has shown a bias in the technique, especially for situations where mass-transfer rates are intensified, or where there is limited liquid holdup in the bulk compared to the film layers. In fact, systematic errors of up to 50% in the interfacial area, and as high as 90% in the mass-transfer coefficients, can be expected for modern, intensified gas–liquid contactors, even within the commonly accepted validity limits of a pseudo-first-order reaction and Hatta numbers in the range of 0.3 < Ha < 3. Given the current computational capabilities and the intensified mass-transfer rates in modern gas–liquid contactors, it is therefore imperative that the equations for reaction and diffusion in the liquid films are numerically solved and subsequently used to fit the interfacial area and mass-transfer coefficient to experimental data, which would traditionally be used in the graphical Danckwerts’ method.

  4. First-principles X-ray absorption dose calculation for time-dependent mass and optical density.

    Berejnov, Viatcheslav; Rubinstein, Boris; Melo, Lis G A; Hitchcock, Adam P

    2018-05-01

    A dose integral of time-dependent X-ray absorption under conditions of variable photon energy and changing sample mass is derived from first principles starting with the Beer-Lambert (BL) absorption model. For a given photon energy the BL dose integral D(e, t) reduces to the product of an effective time integral T(t) and a dose rate R(e). Two approximations of the time-dependent optical density, i.e. exponential A(t) = c + aexp(-bt) for first-order kinetics and hyperbolic A(t) = c + a/(b + t) for second-order kinetics, were considered for BL dose evaluation. For both models three methods of evaluating the effective time integral are considered: analytical integration, approximation by a function, and calculation of the asymptotic behaviour at large times. Data for poly(methyl methacrylate) and perfluorosulfonic acid polymers measured by scanning transmission soft X-ray microscopy were used to test the BL dose calculation. It was found that a previous method to calculate time-dependent dose underestimates the dose in mass loss situations, depending on the applied exposure time. All these methods here show that the BL dose is proportional to the exposure time D(e, t) ≃ K(e)t.

  5. Mixed convection and heat generation/absorption aspects in MHD flow of tangent-hyperbolic nanoliquid with Newtonian heat/mass transfer

    Qayyum, Sajid; Hayat, Tasawar; Shehzad, Sabir Ali; Alsaedi, Ahmed

    2018-03-01

    This article concentrates on the magnetohydrodynamic (MHD) stagnation point flow of tangent hyperbolic nanofluid in the presence of buoyancy forces. Flow analysis caused due to stretching surface. Characteristics of heat transfer are examined under the influence of thermal radiation and heat generation/absorption. Newtonian conditions for heat and mass transfer are employed. Nanofluid model includes Brownian motion and thermophoresis. The governing nonlinear partial differential systems of the problem are transformed into a systems of nonlinear ordinary differential equations through appropriate variables. Impact of embedded parameters on the velocity, temperature and nanoparticle concentration fields are presented graphically. Numerical computations are made to obtain the values of skin friction coefficient, local Nusselt and Sherwood numbers. It is concluded that velocity field enhances in the frame of mixed convection parameter while reverse situation is observed due to power law index. Effect of Brownian motion parameter on the temperature and heat transfer rate is quite reverse. Moreover impact of solutal conjugate parameter on the concentration and local Sherwood number is quite similar.

  6. Radiation measurement and inverse analysis techniques applied on the determination of the apparent mass diffusion coefficient for diverse contaminants and soil samples

    Rey Silva, D.V.F.M.; Oliveira, A.P.; Macacini, J.F.; Da Silva, N.C.; Cipriani, M.; Quinelato, A.L.

    2005-01-01

    Full text of publication follows: The study of the dispersion of radioactive materials in soils and in engineering barriers plays an important role in the safety analysis of nuclear waste repositories. In order to proceed with such kind of study the involved physical properties must be determined with precision, including the apparent mass diffusion coefficient, which is defined as the ratio between the effective mass diffusion coefficient and the retardation factor. Many different experimental and estimation techniques are available on the literature for the identification of the diffusion coefficient and this work describes the implementation of that developed by Pereira et al [1]. This technique is based on non-intrusive radiation measurements and the experimental setup consists of a cylindrical column filled with compacted media saturated with water. A radioactive contaminant is mixed with a portion of the media and then placed in the bottom of the column. Therefore, the contaminant will diffuse through the uncontaminated media due to the concentration gradient. A radiation detector is used to measure the number of counts, which is associated to the contaminant concentration, at several positions along the column during the experiment. Such measurements are then used to estimate the apparent diffusion coefficient of the contaminant in the porous media by inverse analysis. The inverse problem of parameter estimation is solved with the Levenberg-Marquart Method of minimization of the least-square norm. The experiment was optimized with respect to the number of measurement locations, frequency of measurements and duration of the experiment through the analysis of the sensitivity coefficients and by using a D-optimum approach. This setup is suitable for studying a great number of combinations of diverse contaminants and porous media varying in composition and compacting, with considerable easiness and reliable results, and it was chosen because that is the

  7. Matching the laser wavelength to the absorption properties of matrices increases the ion yield in UV-MALDI mass spectrometry.

    Wiegelmann, Marcel; Soltwisch, Jens; Jaskolla, Thorsten W; Dreisewerd, Klaus

    2013-09-01

    A high analytical sensitivity in ultraviolet matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) is only achieved if the laser wavelength corresponds to a high optical absorption of the matrix. Laser fluence and the physicochemical properties of the compounds, e.g., the proton affinity, also influence analytical sensitivity significantly. In combination, these parameters determine the amount of material ejected per laser pulse and the ion yield, i.e., the fraction of ionized biomolecules. Here, we recorded peptide ion signal intensities as a function of these parameters. Three cinnamic acid matrices were investigated: α-cyano-4-hydroxycinnamic acid, α-cyano-4-chlorocinnamic acid, and α-cyano-2,4-difluorocinnamic acid. In addition, 2,5-dihydroxybenzoic acid was used in comparison experiments. Ion signal intensities "per laser shot" and integrated ion signal intensities were acquired over 900 consecutive laser pulses applied on distinct positions on the dried-droplet sample preparations. With respect to laser wavelength, the two standard MALDI wavelengths of 337/355 nm were investigated. Also, 305 or 320 nm was selected to account for the blue-shifted absorption profiles of the halogenated derivatives. Maximal peptide ion intensities were obtained if the laser wavelength fell within the peak of the absorption profile of the compound and for fluences two to three times the corresponding ion detection threshold. The results indicate ways for improving the analytical sensitivity in MALDI-MS, and in particular for MALDI-MS imaging applications where a limited amount of material is available per irradiated pixel.

  8. Critical evaluation of analytical performance of atomic absorption spectrometry and inductively coupled plasma mass spectrometry for mercury determination

    Krata, A.; Bulska, E.

    2005-01-01

    The analytical performance of cold vapor atomic absorption spectrometry (CV AAS), graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma mass spectrometry (ICP-MS) for mercury determination have been investigated with the use of two reference materials SRM 2710 Montana I Soil and BCR-144R (sewage sludge from domestic origin). The digestion conditions and their influence on determination of mercury have been studied. Samples were decomposed by microwave digestion in closed vessels with the use of HCl alone or mixture of HCl+HNO 3 +HF. The digestion solutions were analyzed by CV AAS using NaBH 4 as a reducing agent, by GF AAS with Pd or mixture of Pd/Rh as modifiers and by ICP-MS with Rh as internal standard. In the case of CV AAS, results were not dependent on digestion conditions. In the case of GF AAS and ICP-MS, results depended significantly on digestion conditions; in both cases, the use of the mixture of acids as defined above suppressed the signal of mercury. Therefore, in those cases, the microwave digestion with HCl is recommended. Detection limits of 0.003, 0.01 and 0.2 μg g -1 were achieved by ICP-MS, CV AAS and GF AAS, respectively

  9. Human Vitamin B12 Absorption and Metabolism are Measured by Accelerator Mass Spectrometry Using Specifically Labeled 14C-Cobalamin

    Carkeet, C; Dueker, S R; Lango, J; Buchholz, B A; Miller, J W; Green, R; Hammock, B D; Roth, J R; Anderson, P J

    2006-01-01

    There is need for an improved test of human ability to assimilate dietary vitamin B 12 . Assaying and understanding absorption and uptake of B 12 is important because defects can lead to hematological and neurological complications. Accelerator mass spectrometry (AMS) is uniquely suited for assessing absorption and kinetics of 14 C-labeled substances after oral ingestion because it is more sensitive than decay counting and can measure levels of carbon-14 ( 14 C) in microliter volumes of biological samples, with negligible exposure of subjects to radioactivity. The test we describe employs amounts of B 12 in the range of normal dietary intake. The B 12 used was quantitatively labeled with 14 C at one particular atom of the DMB moiety by exploiting idiosyncrasies of Salmonellametabolism. In order to grow aerobically on ethanolamine, S. entericamust be provided with either pre-formed B 12 or two of its precursors: cobinamide and dimethylbenzimidazole (DMB). When provided with 14 C-DMB specifically labeled in the C2 position, cells produced 14 C-B 12 of high specific activity (2.1 GBq/mmol, 58 mCi/mmol) and no detectable dilution of label from endogenous DMB synthesis. In a human kinetic study, a physiological dose (1.5 mg, 2.2 KBq/59 nCi) of purified 14 C-B 12 was administered and showed plasma appearance and clearance curves consistent with the predicted behavior of the pure vitamin. This method opens new avenues for study of B 12 assimilation

  10. Separation Method for Oxygen Mass Transport Coefficient in Two Phase Porous Air Electrodes - Transport in Gas and Solid Polymer or Liquid Electrolyte Phases

    2013-08-06

    of the problem studied Proton exchange membrane fuel cells ( PEMFCs ) are the most promising candidate systems for alternative electricity...characteristic. The limiting current can be used as a tool to study mass transport phenomena in PEMFC because it can provide experimental data for the...coefficient for PEMFCs under in situ conditions based on the galvanostatic discharge of a cell with an interrupted reactant supply. The results indicated

  11. Comparison of approaches for measuring the mass accommodation coefficient for the condensation of water and sensitivities to uncertainties in thermophysical properties.

    Miles, Rachael E H; Reid, Jonathan P; Riipinen, Ilona

    2012-11-08

    We compare and contrast measurements of the mass accommodation coefficient of water on a water surface made using ensemble and single particle techniques under conditions of supersaturation and subsaturation, respectively. In particular, we consider measurements made using an expansion chamber, a continuous flow streamwise thermal gradient cloud condensation nuclei chamber, the Leipzig Aerosol Cloud Interaction Simulator, aerosol optical tweezers, and electrodynamic balances. Although this assessment is not intended to be comprehensive, these five techniques are complementary in their approach and give values that span the range from near 0.1 to 1.0 for the mass accommodation coefficient. We use the same semianalytical treatment to assess the sensitivities of the measurements made by the various techniques to thermophysical quantities (diffusion constants, thermal conductivities, saturation pressure of water, latent heat, and solution density) and experimental parameters (saturation value and temperature). This represents the first effort to assess and compare measurements made by different techniques to attempt to reduce the uncertainty in the value of the mass accommodation coefficient. Broadly, we show that the measurements are consistent within the uncertainties inherent to the thermophysical and experimental parameters and that the value of the mass accommodation coefficient should be considered to be larger than 0.5. Accurate control and measurement of the saturation ratio is shown to be critical for a successful investigation of the surface transport kinetics during condensation/evaporation. This invariably requires accurate knowledge of the partial pressure of water, the system temperature, the droplet curvature and the saturation pressure of water. Further, the importance of including and quantifying the transport of heat in interpreting droplet measurements is highlighted; the particular issues associated with interpreting measurements of condensation

  12. Paleodiet characterisation of an Etrurian population of Pontecagnano (Italy) by Isotope Ratio Mass Spectrometry (IRMS) and Atomic Absorption Spectrometry (AAS)(#).

    Scarabino, Carla; Lubritto, Carmine; Proto, Antonio; Rubino, Mauro; Fiengo, Gilda; Marzaioli, Fabio; Passariello, Isabella; Busiello, Gaetano; Fortunato, Antonietta; Alfano, Davide; Sabbarese, Carlo; Rogalla, Detlef; De Cesare, Nicola; d'Onofrio, Antonio; Terrasi, Filippo

    2006-06-01

    Human bones recovered from the archaeological site of Pontecagnano (Salerno, Italy) have been studied to reconstruct the diet of an Etrurian population. Two different areas were investigated, named Library and Sant' Antonio, with a total of 44 tombs containing human skeletal remains, ranging in age from the 8th to the 3rd century B.C. This time span was confirmed by 14C dating obtained using Accelerator Mass Spectrometry (AMS) on one bone sample from each site. Atomic Absorption Spectrometry (AAS) was used to extract information about the concentration of Sr, Zn, Ca elements in the bone inorganic fraction, whilst stable isotope ratio measurements (IRMS) were carried out on bone collagen to obtain the delta13C and delta15N. A reliable technique has been used to extract and separate the inorganic and organic fractions of the bone remains. Both IRMS and AAS results suggest a mixed diet including C3 plant food and herbivore animals, consistent with archaeological indications.

  13. Influence of fluid-mechanical characteristics of the system on the volumetric mass transfer coefficient and gas dispersion in three-phase system

    Knežević Milena M.

    2014-01-01

    Full Text Available Distribution of gas bubbles and volumetric mass transfer coefficient, Kla, in a three phase system, with different types of solid particles at different operation conditions were studied in this paper. The ranges of superficial gas and liquid velocities used in this study were 0,03-0,09 m/s and 0-0,1 m/s, respectively. The three different types of solid particles were used as a bed in the column (glass dp=3 mm, dp=6 mm; ceramic dp=6 mm. The experiments were carried out in a 2D plexiglas column, 278 x 20,4 x 500 mm and in a cylindrical plexiglas column, with a diameter of 64 mm and a hight of 2000 mm. The Kla coefficient increased with gas and liquid velocities. Results showed that the volumetric mass transfer coefficient has a higher values in three phase system, with solid particles, compared with two phase system. The particles properties (diameter and density have a major impact on oxygen mass transfer in three phase systems.

  14. Experimental evaluation of the objective virtual mass coefficient; Avaliacao experimental do coeficiente de massa virtual apoiada em uma formulacao objetiva

    Heilbron Filho, Paulo Fernando Lavalle

    1984-04-15

    This work is a continuation of many others studies that have been made in the field of two-phase flow, concerning the influence of the void fraction in a parameter known as 'induced mass' that appears in the constitutive equation of the inter-phase force called 'virtual mass force'. The determination of the influence of the void fraction in the induced mass is done using experiment involving a bubble flow in a vertical tube filled with water. Using the two-phase flow model together with some hypothesis concerning the bubble flow experience and the constitutive equation for the virtual mass force, we achieve through the analysis of the filming of the experiment our purpose in determining the influence of the void fraction on the induced mass. (author)

  15. Experimental evaluation of the objective virtual mass coefficient; Avaliacao experimental do coeficiente de massa virtual apoiada em uma formulacao objetiva

    Heilbron Filho, Paulo Fernando Lavalle

    1984-04-15

    This work is a continuation of many others studies that have been made in the field of two-phase flow, concerning the influence of the void fraction in a parameter known as 'induced mass' that appears in the constitutive equation of the inter-phase force called 'virtual mass force'. The determination of the influence of the void fraction in the induced mass is done using experiment involving a bubble flow in a vertical tube filled with water. Using the two-phase flow model together with some hypothesis concerning the bubble flow experience and the constitutive equation for the virtual mass force, we achieve through the analysis of the filming of the experiment our purpose in determining the influence of the void fraction on the induced mass. (author)

  16. Measurement of graphite and aluminium absorption cross sections via reactor period by danger coefficient method; Merenje apsorpcionih preseka grafita i aluminijuma preko periode reaktora metodom koeficijenta opasnosti

    Petrovic, M; Markovic, V; Velickovic, Lj [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1963-07-01

    Full text: This activity is a logical continuation of the experiment at the RA reactor during 1962 which was based on compensating the effect by means of control rod. Since results are given with significant errors, new method for measuring the absorption cross sections via reactor period. Experiment was done at the RB reactor which was particularly prepared for this type of experiments. Reactor power was from 50 mW to 2 W. Absorption cross sections were measured for two types of material: domestic graphite No.3 and French graphite 'Pachiney', and two types of aluminium. Total errors in applying this method are {+-} 5%, where the source of major part of error comes from uncertainty of the standard absorption power (previous method gave {+-} 10 do 55% ). Comparison of French graphite absorption cross section obtained via reactor period and via control rod showed approximate agreement with discrepancy of 5.4% which is considered within the precision of this method. Considering the accuracy of measurement results and reactor economy it is concluded that measuring absorption cross sections of samples via period of RB reactor is more favourable than measurements by control rod at the RA reactor. Pun tekst: Ovaj rad predstavlja logican nastavak eksperimenta na reaktoru RA u toku 1962. godine, koji je bazirao na kompenzaciji efekta pomocu kontrolne sipke. Kako su rezultati dati sa velikim greskama, to se prislo novom nacinu merenja apsorpsionih preseka preko periode reaktora. Eksperiment je radjen na reaktoru RB koji je specijalno pripremljen za ovu vrstu eksperimenta. Snaga reaktora se kretala od 50 mW do 2 W. Preko periode reaktora RB odredjeni su apsorpcioni preseci za dve vrste materijala i to: domaci grafit No.3 i francuski 'Pachiney', i dve vrste aluminijuma. Ukupne greske pri ovom nacimu merenja iznose oko {+-} 5%, gde glavni deo greske nosi neodredjenost apsorpcione moci standarda (ranija metoda je dala {+-} 10 do 55% ). Poredjenjem vrednosti apsorpcionih preseka

  17. THE H I MASS DENSITY IN GALACTIC HALOS, WINDS, AND COLD ACCRETION AS TRACED BY Mg II ABSORPTION

    Kacprzak, Glenn G. [Swinburne University of Technology, Victoria 3122 (Australia); Churchill, Christopher W., E-mail: gkacprzak@astro.swin.edu.au, E-mail: cwc@nmsu.edu [New Mexico State University, Las Cruces, NM 88003 (United States)

    2011-12-20

    It is well established that Mg II absorption lines detected in background quasar spectra arise from gas structures associated with foreground galaxies. The degree to which galaxy evolution is driven by the gas cycling through halos is highly uncertain because their gas mass density is poorly constrained. Fitting the Mg II equivalent width (W) distribution with a Schechter function and applying the N(H I)-W correlation of Menard and Chelouche, we computed {Omega}(H I){sub MgII} {identical_to} {Omega}(H I){sub halo} = 1.41{sup +0.75}{sub -0.44} Multiplication-Sign 10{sup -4} for 0.4 {<=} z {<=} 1.4. We exclude damped Ly{alpha}'s (DLAs) from our calculations so that {Omega}(H I){sub halo} comprises accreting and/or outflowing halo gas not locked up in cold neutral clouds. We deduce that the cosmic H I gas mass density fraction in galactic halos traced by Mg II absorption is {Omega}(H I){sub halo}/{Omega}(H I){sub DLA} {approx_equal} 15% and {Omega}(H I){sub halo}/{Omega}{sub b} {approx_equal} 0.3%. Citing several lines of evidence, we propose that infall/accretion material is sampled by small W whereas outflow/winds are sampled by large W, and find that {Omega}(H I){sub infall} is consistent with {Omega}(H I){sub outflow} for bifurcation at W = 1.23{sup +0.15}{sub -0.28} Angstrom-Sign ; cold accretion would then comprise no more than {approx}7% of the total H I mass density. We discuss evidence that (1) the total H I mass cycling through halos remains fairly constant with cosmic time and that the accretion of H I gas sustains galaxy winds, and (2) evolution in the cosmic star formation rate depends primarily on the rate at which cool H I gas cycles through halos.

  18. Coupling between mass transfer and chemical reactions during the absorption of CO2 in a NaHCO3-Na2CO3 brine :experimental and theoretical study

    Wylock, Christophe; Colinet, Pierre; Cartage, Thierry; Haut, Benoît

    2008-01-01

    This work deals with the study of the gas-liquid mass transfer, coupled with chemical reactions. The case of carbonic gas absorption in a brine of sodium carbonate and bicarbonate is investigated. It is performed in collaboration with Solvay SA. The aim of this work is to get a better understanding of this phenomenon. It would permit an optimization of the refined sodium bicarbonate production process. The basis of developed mathematical models is presented. The CO2 absorption is coupled with...

  19. Self-broadening coefficients and positions of acetylene around 1.533 μm studied by high-resolution diode laser absorption spectrometry

    Li Jingsong; Durry, Georges; Cousin, Julien; Joly, Lilian; Parvitte, Bertrand; Zeninari, Virginie

    2010-01-01

    The self-broadening coefficients of acetylene at room temperature have been measured for 10 lines in the P branch of the ν 1 +ν 3 (Σ u + )-0(Σ g + ) bands of 12 C 2 H 2 and 13 C 12 CH 2 near 1.533 μm, using a high resolution tunable diode laser spectrometer developed for the Martian space mission PHOBOS-Grunt. The collisional widths are obtained by fitting each recorded line with the Voigt profile as well as the Rautian profile accounting for the collisional Dicke narrowing effect. The standard Voigt model provides slightly smaller broadening coefficients than the Rautian model. Our data are thoroughly compared to the main atmospheric molecule database HITRAN and previous values in various bands of acetylene. Moreover, it is worth noting that a large number of new transitions not listed in the latest HITRAN08 were measured and identified for the first time.

  20. Measurements of local mass transfer coefficient of Flow Accelerated Corrosion at feeder outlet pipes in CANDU using Plaster of Paris method

    Hyuk Kwon; Dong Un Seo; Goon-Cherl Park

    2005-01-01

    Full text of publication follows: Flow Accelerated Corrosion (FAC) is a corrosion mechanism that results in wall thinning in piping systems and components. FAC on carbon steels in pure water has occurred in a number of industry and power plant. A pipe wall thinning due to the FAC at nuclear power plant is just reported in confined to carbon steel pipe on the secondary system which does not equip a radioactive component. Recently, at Canadian Deuterium Uranium type reactor, it is reported that the feeder lines suffer the wall thinning on the primary system to equip 380 feeder pipes. Differently from the fast FAC rate of the secondary system on PWR, FAC rate of feeder pipes on CANDU is not more than the 0.2 mm/year. Although the FAC rate of feeder pipe is relatively slow, the narrow thickness margin of 2.6089 mm is endangered sufficiently by only the slow FAC rate. The FAC is governed by the mass transfer coefficient which is determined by the flow field. To well predict the FAC rate, mass transfer coefficient should be well measured or calculated. New measurement method of mass transfer coefficient is developed to obtain the coefficient for the complex shape like feeder pipe. The method evaluated the naphthalene sublimation method to apply it under the water flow. The naphthalene sublimation method can be used to study mass and heat transfer with confidence for a variety of applications, but with certain restrictions. At present, Plaster of paris method can modified the sublimation method to overcome the restrictions. This method is particularly useful in complex flows on geometries and for flows with large gradients in wall transport rate. The test specimen can be easily prepared by several methods, including dipping, machining, spraying, and casting. The local transfer coefficients can be determined with high accuracy and in detail by automated measurement systems that eliminate most human errors during the measurement process. To evaluate the method, the

  1. Photon mass attenuation coefficients of a silicon resin loaded with WO3, PbO, and Bi2O3 Micro and Nano-particles for radiation shielding

    Verdipoor, Khatibeh; Alemi, Abdolali; Mesbahi, Asghar

    2018-06-01

    Novel shielding materials for photons based on silicon resin and WO3, PbO, and Bi2O3 Micro and Nano-particles were designed and their mass attenuation coefficients were calculated using Monte Carlo (MC) method. Using lattice cards in MCNPX code, micro and nanoparticles with sizes of 100 nm and 1 μm was designed inside a silicon resin matrix. Narrow beam geometry was simulated to calculate the attenuation coefficients of samples against mono-energetic beams of Co60 (1.17 and 1.33 MeV), Cs137 (663.8 KeV), and Ba133 (355.9 KeV). The shielding samples made of nanoparticles had higher mass attenuation coefficients, up to 17% relative to those made of microparticles. The superiority of nano-shields relative to micro-shields was dependent on the filler concentration and the energy of photons. PbO, and Bi2O3 nanoparticles showed higher attenuation compared to WO3 nanoparticles in studied energies. Fabrication of novel shielding materials using PbO, and Bi2O3 nanoparticles is recommended for application in radiation protection against photon beams.

  2. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale.

    Klöckner, Wolf; Gacem, Riad; Anderlei, Tibor; Raven, Nicole; Schillberg, Stefan; Lattermann, Clemens; Büchs, Jochen

    2013-12-02

    Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham's π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/- 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.

  3. Absorption/desorption in sprays

    Naimpally, A.

    1987-01-01

    This survey paper shall seek to present the present state of knowledge concerning absorption and desorption in spray chambers. The first part of the paper presents the theories and formulas for the atomization and break-up of sprays in nozzles. Formulas for the average (sauter-mean) diameters are then presented. For the case of absorption processes, the formulas for the dimensionless mass transfer coefficients is in drops. The total; mass transfer is the total of the transfer in individual drops. For the case of desorption of sparingly soluble gases from liquids in a spray chamber, the mass transfer occurs in the spray just at the point of break-up of the jet. Formulas for the desorption of gases are presented

  4. Gold analysis by the gamma absorption technique

    Kurtoglu, Arzu; Tugrul, A.B.

    2003-01-01

    Gold (Au) analyses are generally performed using destructive techniques. In this study, the Gamma Absorption Technique has been employed for gold analysis. A series of different gold alloys of known gold content were analysed and a calibration curve was obtained. This curve was then used for the analysis of unknown samples. Gold analyses can be made non-destructively, easily and quickly by the gamma absorption technique. The mass attenuation coefficients of the alloys were measured around the K-shell absorption edge of Au. Theoretical mass attenuation coefficient values were obtained using the WinXCom program and comparison of the experimental results with the theoretical values showed generally good and acceptable agreement

  5. Influence of high range of mass transfer coefficient and convection heat transfer on direct contact membrane distillation performance

    Lee, Jung Gil; Jeong, Sanghyun; Alsaadi, Ahmad Salem; Ghaffour, NorEddine

    2017-01-01

    (>2.1×10−6kg/m2sPa: membranes under development) were simulated using an experimentally validated model at different ranges of convection heat transfer by varying the inlet flow rates and spacer enhancement factor. The effect of mass transfer

  6. Experimental investigation of the liquid volumetric mass transfer coefficient for upward gas-liquid two-phase flow in rectangular microchannels

    X. Y. Ji

    2010-12-01

    Full Text Available The gas-liquid two-phase mass transfer process in microchannels is complicated due to the special dynamical characteristics. In this work, a novel method was explored to measure the liquid side volumetric mass transfer coefficient kLa. Pressure transducers were utilized to measure the pressure variation of upward gas-liquid two-phase flow in three vertical rectangular microchannels and the liquid side volumetric mass transfer coefficient kLa was calculated through the Pressure-Volume-Temperature correlation of the gas phase. Carbon dioxide-water, carbon dioxide-ethanol and carbon dioxide-n-propanol were used as working fluids, respectively. The dimensions of the microchannels were 40 µm×240 µm (depth×width, 100 µm×800 µm and 100 µm×2000 µm, respectively. Results showed that the channel diameter and the capillary number influence kLa remarkably and that the maximum value of kLa occurs in the annular flow regime. A new correlation of kLa was proposed based on the Sherwood number, Schmidt number and the capillary number. The predicted values of kLa agreed well with the experimental data.

  7. Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow.

    Volani, Chiara; Caprioli, Giulia; Calderisi, Giovanni; Sigurdsson, Baldur B; Rainer, Johannes; Gentilini, Ivo; Hicks, Andrew A; Pramstaller, Peter P; Weiss, Guenter; Smarason, Sigurdur V; Paglia, Giuseppe

    2017-10-01

    Volumetric absorptive microsampling (VAMS) is a novel approach that allows single-drop (10 μL) blood collection. Integration of VAMS with mass spectrometry (MS)-based untargeted metabolomics is an attractive solution for both human and animal studies. However, to boost the use of VAMS in metabolomics, key pre-analytical questions need to be addressed. Therefore, in this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. We first evaluated the best extraction procedure for the polar metabolome and found that the highest number and amount of metabolites were recovered upon extraction with acetonitrile/water (70:30). In contrast, basic conditions (pH 9) resulted in divergent metabolite profiles mainly resulting from the extraction of intracellular metabolites originating from red blood cells. In addition, the prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but once the VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months. The time used for drying the sample did also affect the metabolome. In fact, some metabolites were rapidly degraded or accumulated in the sample during the first 48 h at room temperature, indicating that a longer drying step will significantly change the concentration in the sample. Graphical abstract Volumetric absorptive microsampling (VAMS) is a novel technology that allows single-drop blood collection and, in combination with mass spectrometry (MS)-based untargeted metabolomics, represents an attractive solution for both human and animal studies. In this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. The latter revealed that

  8. Film mass transfer coefficient for the prediction of volatile organic compound evaporation rate from open water basin

    Charun Bunyakan; Preyaporn Tongsoi; Chakrit Tongurai

    2001-01-01

    The evaporation of volatile organic compounds(VOCs) from treatment, storage, disposal facility(TSDF) is an important air pollution issue because of the evaporation quantity and toxicity and/or carcinogenicity. This paper concerns VOC evaporation from open water basins such as the equalization basin and nonaerate surface impoundments in a wastewater treatment plant. The amount of VOCs evaporation from open water basins can be predicted by using the two-film model that requires two mass transfe...

  9. Estimation of air-water gas exchange coefficient in a shallow lagoon based on 222Rn mass balance.

    Cockenpot, S; Claude, C; Radakovitch, O

    2015-05-01

    The radon-222 mass balance is now commonly used to quantify water fluxes due to Submarine Groundwater Discharge (SGD) in coastal areas. One of the main loss terms of this mass balance, the radon evasion to the atmosphere, is based on empirical equations. This term is generally estimated using one among the many empirical equations describing the gas transfer velocity as a function of wind speed that have been proposed in the literature. These equations were, however, mainly obtained from areas of deep water and may be less appropriate for shallow areas. Here, we calculate the radon mass balance for a windy shallow coastal lagoon (mean depth of 6m and surface area of 1.55*10(8) m(2)) and use these data to estimate the radon loss to the atmosphere and the corresponding gas transfer velocity. We present new equations, adapted to our shallow water body, to express the gas transfer velocity as a function of wind speed at 10 m height (wind range from 2 to 12.5 m/s). When compared with those from the literature, these equations fit particularly well with the one of Kremer et al. (2003). Finally, we emphasize that some gas transfer exchange may always occur, even for conditions without wind. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Determination of the profile of DO and its mass transferring coefficient in a biofilm reactor packed with semi-suspended bio-carriers.

    Tang, Bing; Song, Haoliang; Bin, Liying; Huang, Shaosong; Zhang, Wenxiang; Fu, Fenglian; Zhao, Yiliang; Chen, Qianyu

    2017-10-01

    The work aims at illustrating the profile of DO and its mass transferring process in a biofilm reactor packed with a novel semi-suspended bio-carrier, and further revealing the main factors that influence the mass transferring coefficient of DO within the biofilm. Results showed that the biofilm was very easy to attach and grow on the semi-suspended bio-carrier, which obviously changed the DO profile inside and outside the biofilm. The semi-suspended bio-carrier caused three different mass transfer zones occurring in the bioreactor, including the zones of bulk solution, boundary layer and biofilm, in which, the boundary layer zone had an obvious higher mass transfer resistance. Increasing the aeration rate might improve the hydrodynamic conditions in the bioreactor and accelerate the mass transfer of DO, but it also detached the biofilm from the surface of bio-carrier, which reduced the consumption of DO, and accordingly, decreased the DO gradient in the bioreactor. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Effects of probiotics, prebiotics, and synbiotics on mineral metabolism in ovariectomized rats — impact of bacterial mass, intestinal absorptive area and reduction of bone turn-over

    Katharina E. Scholz-Ahrens

    2016-08-01

    Conclusion: SYN exerted a synergistic effect on bone mineralization, presumably due to changes in gut microbiota and ecology associated with large bowel digesta weight (most likely reflecting microbial mass and with large bowel weight (reflecting absorptive area, while bone turnover tended to be reduced as indicated by BAP.

  12. Experimental validation of the Maxwell-Stefan theory for the description of liquid-side mass transfer-absorption of NH3 in water using a stirred cell.

    Frank, M.J.W.; Frank, M.J.W.; Kuipers, J.A.M.; van Swaaij, Willibrordus Petrus Maria

    1996-01-01

    The main goal of this paper is to demonstrate the validity of the Maxwell-Stefan theory for the description of liquid phase mass transport processes in a binary mixture. To critically test this theory absorption experiments of ammonia in water were conducted in a stirred cell. The flux model

  13. The Stellar Initial Mass Function in Early-type Galaxies from Absorption Line Spectroscopy. I. Data and Empirical Trends

    van Dokkum, Pieter G.; Conroy, Charlie

    2012-11-01

    The strength of gravity-sensitive absorption lines in the integrated light of old stellar populations is one of the few direct probes of the stellar initial mass function (IMF) outside of the Milky Way. Owing to the advent of fully depleted CCDs with little or no fringing it has recently become possible to obtain accurate measurements of these features. Here, we present spectra covering the wavelength ranges 0.35-0.55 μm and 0.72-1.03 μm for the bulge of M31 and 34 early-type galaxies from the SAURON sample, obtained with the Low Resolution Imaging Spectrometer on Keck. The signal-to-noise ratio is >~ 200 Å-1 out to 1 μm, which is sufficient to measure gravity-sensitive features for individual galaxies and to determine how they depend on other properties of the galaxies. Combining the new data with previously obtained spectra for globular clusters in M31 and the most massive elliptical galaxies in the Virgo cluster, we find that the dwarf-sensitive Na I λ8183, 8195 doublet and the FeH λ9916 Wing-Ford band increase systematically with velocity dispersion, while the giant-sensitive Ca II λ8498, 8542, 8662 triplet decreases with dispersion. These trends are consistent with a varying IMF, such that galaxies with deeper potential wells have more dwarf-enriched mass functions. In a companion paper, we use a comprehensive stellar population synthesis model to demonstrate that IMF effects can be separated from age and abundance variations and quantify the IMF variation among early-type galaxies.

  14. THE STELLAR INITIAL MASS FUNCTION IN EARLY-TYPE GALAXIES FROM ABSORPTION LINE SPECTROSCOPY. I. DATA AND EMPIRICAL TRENDS

    Van Dokkum, Pieter G.; Conroy, Charlie

    2012-01-01

    The strength of gravity-sensitive absorption lines in the integrated light of old stellar populations is one of the few direct probes of the stellar initial mass function (IMF) outside of the Milky Way. Owing to the advent of fully depleted CCDs with little or no fringing it has recently become possible to obtain accurate measurements of these features. Here, we present spectra covering the wavelength ranges 0.35-0.55 μm and 0.72-1.03 μm for the bulge of M31 and 34 early-type galaxies from the SAURON sample, obtained with the Low Resolution Imaging Spectrometer on Keck. The signal-to-noise ratio is ∼> 200 Å –1 out to 1 μm, which is sufficient to measure gravity-sensitive features for individual galaxies and to determine how they depend on other properties of the galaxies. Combining the new data with previously obtained spectra for globular clusters in M31 and the most massive elliptical galaxies in the Virgo cluster, we find that the dwarf-sensitive Na I λ8183, 8195 doublet and the FeH λ9916 Wing-Ford band increase systematically with velocity dispersion, while the giant-sensitive Ca II λ8498, 8542, 8662 triplet decreases with dispersion. These trends are consistent with a varying IMF, such that galaxies with deeper potential wells have more dwarf-enriched mass functions. In a companion paper, we use a comprehensive stellar population synthesis model to demonstrate that IMF effects can be separated from age and abundance variations and quantify the IMF variation among early-type galaxies.

  15. Evaluation of the use of partition coefficients and molecular surface properties as predictors of drug absorption: a provisional biopharmaceutical classification of the list of national essential medi

    NU Rahman

    2011-05-01

    Full Text Available Background and the purpose of the study: Partition coefficients (log D and log P and molecular surface area (PSA are potential predictors of the intestinal permeability of drugs. The aim of this investigation was to evaluate and compare these intestinal permeability indicators.   Methods: Aqueous solubility data were obtained from literature or calculated using ACD/Labs and ALOGPS. Permeability data were predicted based on log P, log D at pH 6.0 (log D6.0, and PSA.  Results: Metoprolol's log P, log D6.0 and a PSA of <65 Å correctly predicted 55.9%, 50.8% and 54.2% of permeability classes, respectively. Labetalol's log P, log D6.0, and PSA correctly predicted 54.2%, 64.4% and 61% of permeability classes, respectively. Log D6.0 correlated well (81% with Caco-2 permeability (Papp. Of the list of national essential medicines, 135 orally administered drugs were classified into biopharmaceutical classification system (BCS. Of these, 57 (42.2%, 28 (20.7%, 44 (32.6%, and 6 (4.4% were class I, II, III and IV respectively. Conclusion: Log D6.0 showed better prediction capability than log P. Metoprolol as permeability internal standard was more conservative than labetalol.

  16. Experimental evidence supporting the insensitivity of cloud droplet formation to the mass accommodation coefficient for condensation of water vapor to liquid water

    Langridge, Justin M.; Richardson, Mathews S.; Lack, Daniel A.; Murphy, Daniel M.

    2016-06-01

    The mass accommodation coefficient for uptake of water vapor to liquid water, αM, has been constrained using photoacoustic measurements of aqueous absorbing aerosol. Measurements performed over a range of relative humidities and pressures were compared to detailed model calculations treating coupled heat and mass transfer occurring during photoacoustic laser heating cycles. The strengths and weaknesses of this technique are very different to those for droplet growth/evaporation experiments that have typically been applied to these measurements, making this a useful complement to existing studies. Our measurements provide robust evidence that αM is greater than 0.1 for all humidities tested and greater than 0.3 for data obtained at relative humidities greater than 88% where the aerosol surface was most like pure water. These values of αM are above the threshold at which kinetic limitations are expected to impact the activation and growth of aerosol particles in warm cloud formation.

  17. Determination of diffusion coefficients of hydrogen and deuterium in Zr–2.5%Nb pressure tube material using hot vacuum extraction-quadrupole mass spectrometry

    Shrivastava, Komal Chandra, E-mail: komal@barc.gov.in [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kulkarni, A.S.; Ramanjaneyulu, P.S. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Sunil, Saurav [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Saxena, M.K. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Singh, R.N. [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Tomar, B.S.; Ramakumar, K.L. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2015-06-15

    The diffusion coefficients of hydrogen and deuterium in Zr–2.5%Nb alloy were measured in the temperature range 523 to 673 K, employing hot vacuum extraction-quadrupole mass spectrometry (HVE-QMS). One end of the Zr–2.5%Nb alloy specimens was charged electrolytically with the desired hydrogen isotope. After annealing at different temperatures for a predetermined time, the specimens were cut into thin slices, which were analyzed for their H{sub 2}/D{sub 2} content using the HVE-QMS technique. The depth profile data were fitted into the equation representing the solution of Fick’s second law of diffusion. The activation energy of hydrogen/deuterium diffusion was obtained from the Arrhenius relation between the diffusion coefficient and temperature. The temperature dependent diffusion coefficient can be represented as D{sub H} = 1.41 × 10{sup −7} exp(−36,000/RT) and D{sub D} = 6.16 × 10{sup −8} exp(−35,262/RT) for hydrogen and deuterium, respectively.

  18. Absorption coefficients for interband optical transitions in a strained InAs1−xPx/InP quantum wire

    Saravanan, S.; John Peter, A.; Lee, Chang Woo

    2014-01-01

    Excitons confined in an InAs 1−x P x /InP (x=0.2) quantum well wire are studied in the presence of magnetic field strength. Numerical calculations are carried out using variational approach within the single band effective mass approximation. The compressive strain contribution to the confinement potential is included throughout the calculations. The energy difference of the ground and the first excited state is investigated in the influence of magnetic field strength taking into account the geometrical confinement effect. The magnetic field induced optical band as a function of wire radius is investigated in the InAs 0.8 P 0.2 /InP quantum well wire. The valence-band anisotropy is included in our theoretical model by employing different hole masses in different spatial directions. The optical gain as a function of incident photon energy is computed in the presence of magnetic field strength. The corresponding 1.55 μm wavelength is achieved for 40 Å InAs 0.8 P 0.2 /InP quantum well wire. We hope that the results could be used for the potential applications in fiber optic communications. -- Highlights: • Magnetic field induced excitons confined in a InAs 1−x P x /InP (x=0.2) quantum well wire are studied. • The compressive strain is included throughout the calculations. • The energy difference of the ground and the first excited state is investigated in the presence of magnetic field strength. • The magnetic field induced optical band with the geometrical confinement is studied. • The optical gain with the photon energy is computed in the presence of magnetic field strength

  19. Evaluation of flow accelerated corrosion by coupled analysis of corrosion and flow dynamics (2), flow dynamics calculations for determining mixing factors and mass transfer coefficients

    Uehara, Yasushi; Uchida, Shunsuke; Naitoh, Masanori; Okada, Hidetoshi; Koshizuka, Seiichi

    2009-01-01

    In order to predict and mitigate flow accelerated corrosion (FAC) of carbon steel piping in PWR and BWR secondary systems, computer program packages for evaluating FAC have been developed by coupling one through three dimensional (1-3D) computational flow dynamics (CFD) models and corrosion models. To evaluate corrosive conditions, e.g., oxygen concentration and electrochemical corrosion potential (ECP) along the flow path, flow pattern and temperature in each elemental volume were obtained with 1D computational flow dynamics (CFD) codes. Precise flow turbulence and mass transfer coefficients at the structure surface were calculated with 3D CFD codes to determine wall thinning rates. One of the engineering options is application of k-ε calculation as a 3D CFD code, which has limitation of detail evaluation of flow distribution at very surface of large scale piping. A combination of k-ε calculation and wall function was proposed to evaluate precise distribution of mass transfer coefficients with reasonable CPU volume and computing time and, at the same time, reasonable accuracy. (author)

  20. Photon absorption of calcium phosphate-based dental biomaterials

    Singh, V. P.; Badiger, N. M.; Tekin, H. O.; Kara, U.; Vega C, H. R.; Fernandes Z, M. A.

    2017-10-01

    Effective atomic number and mass energy absorption buildup factors for four calcium phosphate-based biomaterials used in dental treatments were calculated for 0.015 to 15 MeV photons. The mass energy absorption coefficients were calculated for 0.5 to 40 mean free paths of photons. In the energy region important for dental radiology the Zeff for all studied biomaterials are larger in comparison to larger energies. In x-rays for dental radiology and the energy absorption buildup factors are low, however CbMDI bio material shows a resonance at 80 keV. (Author)

  1. X-ray absorption intensity at high-energy region

    Fujikawa, Takashi; Kaneko, Katsumi

    2012-01-01

    We theoretically discuss X-ray absorption intensity in high-energy region far from the deepest core threshold to explain the morphology-dependent mass attenuation coefficient of some carbon systems, carbon nanotubes (CNTs), highly oriented pyrolytic graphite (HOPG) and fullerenes (C 60 ). The present theoretical approach is based on the many-body X-ray absorption theory including the intrinsic losses (shake-up losses). In the high-energy region the absorption coefficient has correction term dependent on the solid state effects given in terms of the polarization part of the screened Coulomb interaction W p . We also discuss the tail of the valence band X-ray absorption intensity. In the carbon systems C 2s contribution has some influence on the attenuation coefficient even in the high energy region at 20 keV.

  2. Quasi-stationary states of an electron with linearly dependent effective mass in an open nanostructure within transmission coefficient and S-matrix methods

    Seti, Julia; Tkach, Mykola; Voitsekhivska, Oxana

    2018-03-01

    The exact solutions of the Schrödinger equation for a double-barrier open semiconductor plane nanostructure are obtained by using two different approaches, within the model of the rectangular potential profile and the continuous position-dependent effective mass of the electron. The transmission coefficient and scattering matrix are calculated for the double-barrier nanostructure. The resonance energies and resonance widths of the electron quasi-stationary states are analyzed as a function of the size of the near-interface region between wells and barriers, where the effective mass linearly depends on the coordinate. It is established that, in both methods, the increasing size affects in a qualitatively similar way the spectral characteristics of the states, shifting the resonance energies into the low- or high-energy region and increasing the resonance widths. It is shown that the relative difference of resonance energies and widths of a certain state, obtained in the model of position-dependent effective mass and in the widespread abrupt model in physically correct range of near-interface sizes, does not exceed 0.5% and 5%, respectively, independently of the other geometrical characteristics of the structure.

  3. Accurate prediction of H3O+ and D3O+ sensitivity coefficients to probe a variable proton-to-electron mass ratio

    Owens, A.; Yurchenko, S. N.; Polyansky, O. L.; Ovsyannikov, R. I.; Thiel, W.; Špirko, V.

    2015-12-01

    The mass sensitivity of the vibration-rotation-inversion transitions of H316O+, H318O+, and D316O+ is investigated variationally using the nuclear motion program TROVE (Yurchenko, Thiel & Jensen). The calculations utilize new high-level ab initio potential energy and dipole moment surfaces. Along with the mass dependence, frequency data and Einstein A coefficients are computed for all transitions probed. Particular attention is paid to the Δ|k| = 3 and Δ|k - l| = 3 transitions comprising the accidentally coinciding |J, K = 0, v2 = 0+> and |J, K = 3, v2 = 0-> rotation-inversion energy levels. The newly computed probes exhibit sensitivities comparable to their ammonia and methanol counterparts, thus demonstrating their potential for testing the cosmological stability of the proton-to-electron mass ratio. The theoretical TROVE results are in close agreement with sensitivities obtained using the non-rigid and rigid inverter approximate models, confirming that the ab initio theory used in the present study is adequate.

  4. Linear and mass attenuation coefficient for CdTe compound of X-rays from 10 to 100 keV energy range in different phases

    Saim, A., E-mail: saim1989asma@gmail.com; Tebboune, A.; Berkok, H.; Belameiri, N.; Belbachir, A.H.

    2014-07-25

    The Full Potential Linear Muffin Tin Orbitals method within the density functional theory has been utilized to calculate structural and electronic properties of the CdTe compound. We have checked that the CdTe has two phase-transitions from zinc-blend to cinnabar and from cinnabar to rocksalt. We have found that the rigidity, the energy and the nature of the gap change according to the phase change, so we can predict that a CdTe detector may have different behaviors in different phase conditions. In order to investigate this behavior change, the linear and the mass attenuation coefficients of X-ray in rocksalt, zinc-blend and cinnabar structures are calculated from 10 keV to100 keV, using the XCOM data. We have found that when CdTe undergoes a phase transition from zinc-blend to cinnabar, its linear attenuation coefficient decreases down to a value of about 100 times smaller than its initial one, and when it undergoes a transition from cinnabar to rocksalt it increases up to a value about 90 times larger than its initial one.

  5. Model calculation of the characteristic mass for convective and diffusive vapor transport in graphite furnace atomic absorption spectrometry

    Bencs, László, E-mail: bencs.laszlo@wigner.mta.hu [Institute for Solid State Physics and Optics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Laczai, Nikoletta [Institute for Solid State Physics and Optics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Ajtony, Zsolt [Institute of Food Science, University of West Hungary, H-9200 Mosonmagyaróvár, Lucsony utca 15–17 (Hungary)

    2015-07-01

    A combination of former convective–diffusive vapor-transport models is described to extend the calculation scheme for sensitivity (characteristic mass — m{sub 0}) in graphite furnace atomic absorption spectrometry (GFAAS). This approach encompasses the influence of forced convection of the internal furnace gas (mini-flow) combined with concentration diffusion of the analyte atoms on the residence time in a spatially isothermal furnace, i.e., the standard design of the transversely heated graphite atomizer (THGA). A couple of relationships for the diffusional and convectional residence times were studied and compared, including in factors accounting for the effects of the sample/platform dimension and the dosing hole. These model approaches were subsequently applied for the particular cases of Ag, As, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sn, V and Zn analytes. For the verification of the accuracy of the calculations, the experimental m{sub 0} values were determined with the application of a standard THGA furnace, operating either under stopped, or mini-flow (50 cm{sup 3} min{sup −1}) of the internal sheath gas during atomization. The theoretical and experimental ratios of m{sub 0}(mini-flow)-to-m{sub 0}(stop-flow) were closely similar for each study analyte. Likewise, the calculated m{sub 0} data gave a fairly good agreement with the corresponding experimental m{sub 0} values for stopped and mini-flow conditions, i.e., it ranged between 0.62 and 1.8 with an average of 1.05 ± 0.27. This indicates the usability of the current model calculations for checking the operation of a given GFAAS instrument and the applied methodology. - Highlights: • A calculation scheme for convective–diffusive vapor loss in GFAAS is described. • Residence time (τ) formulas were compared for sensitivity (m{sub 0}) in a THGA furnace. • Effects of the sample/platform dimension and dosing hole on τ were assessed. • Theoretical m{sub 0} of 18 analytes were

  6. Molar mass, radius of gyration and second virial coefficient from new static light scattering equations for dilute solutions: application to 21 (macro)molecules.

    Illien, Bertrand; Ying, Ruifeng

    2009-05-11

    New static light scattering (SLS) equations for dilute binary solutions are derived. Contrarily to the usual SLS equations [Carr-Zimm (CZ)], the new equations have no need for the experimental absolute Rayleigh ratio of a reference liquid and solely rely on the ratio of scattered intensities of solutions and solvent. The new equations, which are based on polarizability equations, take into account the usual refractive index increment partial differential n/partial differential rho(2) complemented by the solvent specific polarizability and a term proportional to the slope of the solution density rho versus the solute mass concentration rho(2) (density increment). Then all the equations are applied to 21 (macro)molecules with a wide range of molar mass (0.2equations clearly achieve a better agreement with supplier M values. For macromolecules (M>500 kg mol(-1)), for which the scattered intensity is no longer independent of the scattering angle, the new equations give the same value of the radius of gyration as the CZ equation and consistent values of the second virial coefficient.

  7. Regularity of the interband light absorption coefficient

    Proc. Indian Acad. Sci. (Math. Sci.) Vol. 120, No. 3, June 2010, pp. 351–362. ... 1. Introduction. In the theory of disordered systems, one of the quantities that is ... integrated density of states, whose continuity properties and its behaviour near ...

  8. Absorption Coefficient of Alkali Halides. Part I.

    1979-03-01

    Q7 A*.oj DATA’ SET ±6 4-5. 0.827 T - Elsa - Li,. 1.62, 3..%?. f..224 1 t.-.5 :.13L 312.9 15.8 9.8*6 16. t u.. t...5 ., i lo.~ 6.705 Z6.8 . 87± - c7. 9...With Synchrotron Radiation," Solid State Coimnun., 6, 575 (1968). 168. Saito, H., Saito, S., Onaka, R., and Ikeo, B., "Extreme Ultraviolet Ab- sorption

  9. Absorption of mass and angular momentum by a black hole: Time-domain formalisms for gravitational perturbations, and the small-hole or slow-motion approximation

    Poisson, Eric

    2004-01-01

    The first objective of this work is to obtain practical prescriptions to calculate the absorption of mass and angular momentum by a black hole when external processes produce gravitational radiation. These prescriptions are formulated in the time domain (in contrast with the frequency-domain formalism of Teukolsky and Press) within the framework of black-hole perturbation theory. Two such prescriptions are presented. The first is based on the Teukolsky equation and it applies to general (rotating) black holes. The second is based on the Regge-Wheeler and Zerilli equations and it applies to nonrotating black holes. The second objective of this work is to apply the time-domain absorption formalisms to situations in which the black hole is either small or slowly moving; the mass of the black hole is then assumed to be much smaller than the radius of curvature of the external spacetime in which the hole moves. In the context of this small-hole/slow-motion approximation, the equations of black-hole perturbation theory can be solved analytically, and explicit expressions can be obtained for the absorption of mass and angular momentum. The changes in the black-hole parameters can then be understood in terms of an interaction between the tidal gravitational fields supplied by the external universe and the hole's tidally-induced mass and current quadrupole moments. For a nonrotating black hole the quadrupole moments are proportional to the rate of change of the tidal fields on the hole's world line. For a rotating black hole they are proportional to the tidal fields themselves. When placed in identical environments, a rotating black hole absorbs more energy and angular momentum than a nonrotating black hole

  10. Spectral effects on some physical coefficients of x-Ray interaction with materials of low atomic number

    EL-Kazzaz, S.A.; Youssef, M.; EL-Hadad, S.; and EL-Nadi, L.M.

    1988-01-01

    X-ray spectra were measured before and after passing through some materials of medical importance applying X-ray diffraction. The mass absorption coefficients of these materials were determined at X-ray peak voltages 27, 30 and 42 kV-p making use the measured spectrum and also by using the direct beam absorption. It has been found that the mass absorption coefficients calculated from the X-ray spectral distribution analysis are in general lower than those obtained considering the direct beam method. From the study of the atomic number and energy dependence of the mass absorption coefficients it has been found that the dependence of the coefficients calculated from the spectral distribution is good agreement with the previously studied data for monoenergetic x-ray beam. Also the roentgen - to - Rad conversion factors were determined at the different used energies and materials. The value of the mass absorption coefficients calculated from the spectral distribution is recommended for use in dose calculation

  11. Determination of correction coefficients for quantitative analysis by mass spectrometry. Application to uranium impurities analysis; Recherche des coefficients de correction permettant l'analyse quantitative par spectrometrie de masse. Application a l'analyse d'impuretes dans l'uranium

    Billon, J P [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1970-07-01

    Some of basic principles in spark source mass spectrometry are recalled. It is shown how this method can lead to quantitative analysis when attention is paid to some theoretical aspects. A time constant relation being assumed between the analysed solid sample and the ionic beam it gives we determined experimental relative sensitivity factors for impurities in uranium matrix. Results being in fairly good agreement with: an unelaborate theory on ionization yield in spark-source use of theoretically obtained relative sensitivity factors in uranium matrix has been developed. (author) [French] Apres avoir rappele quelques principes fondamentaux regissant la spectrometrie de masse a etincelles, nous avons montre que moyennant un certain nombre de precautions, il etait possible d'utiliser cette methode en analyse quantitative. Ayant admis qu'il existait une relation constante dans le temps entre l'echantillon solide analyse et le faisceau ionique qui en est issu, nous avons d'abord entrepris de determiner des coefficients de correction experimentaux pour des matrices d'uranium. Les premiers resultats pratiques semblant en accord avec une theorie simple relative au rendement d'ionisation dans la source a etincelles, nous avons etudie la possibilite d'appliquer directement les coefficients theoriques ainsi definis, l'application etant toujours faite sur des matrices d'uranium. (auteur)

  12. Contribution to the benchmark for ternary mixtures: Measurement of diffusion and Soret coefficients of ternary system tetrahydronaphtalene-isobutylbenzene-n-dodecane with mass fractions 80-10-10 at 25 °C.

    Galand, Quentin; Van Vaerenbergh, Stéfan

    2015-04-01

    This paper provides the molecular diffusion and Soret coefficients of the ternary system 1,2,3,4-tetrahydronaphtalene, isobutylbenzene, n -dodecane system at mass fractions 0.8-0.1-0.1 and temperature 25 (°)C for implementation into the benchmark presented in this topical issue. The Soret coefficients are determined by digital interferometry using the data of DSC-DCMIX microgravity experiment. The method used takes into account the influence of the thermal field on the Soret separations and the selection of the image processing techniques results in reproducible Soret coefficients.The diffusion coefficients are obtained by the Open Ended Capillary technique The fitting of the data collected through a set of two complementary experimental runs allows retrieving the four Fickian diffusion coefficients.

  13. Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

    Aklamati, E.K.; Mulenga, M.; Dueker, S.R.; Buchholz, B.A.; Peerson, J.M.; Kafwembe, E.; Brown, K.H.; Haskell, M.J.

    2009-01-01

    A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children 14 C 2 )-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of 14 C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting 14 C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 ± 7.1%, 76.3 ± 6.7%, and 1.9 ± 0.6%/d, respectively, for the HD-VAS and 76.5 ± 9.5%, 71.1 ± 9.4%, and 1.8 ± 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

  14. Performance analysis of a continuous serpentine flow reactor for electrochemical oxidation of synthetic and real textile wastewater: Energy consumption, mass transfer coefficient and economic analysis.

    Pillai, Indu M Sasidharan; Gupta, Ashok K

    2017-05-15

    A continuous flow electrochemical reactor was developed, and its application was tested for the treatment of textile wastewater. A parallel plate configuration with serpentine flow was chosen for the continuous flow reactor. Uniparameter optimization was carried out for electrochemical oxidation of synthetic and real textile wastewater (collected from the inlet of the effluent treatment plant). Chemical Oxygen Demand (COD) removal efficiency of 90% was achieved for synthetic textile wastewater (initial COD - 780 mg L -1 ) at a flow rate of 500 mL h -1 (retention time of 6 h) and a current density of 1.15 mA cm -2 and the energy consumption for the degradation was 9.2 kWh (kg COD) -1 . The complete degradation of real textile wastewater (initial COD of 368 mg L -1 ) was obtained at a current density of 1.15 mA cm -2 , NaCl concentration of 1 g L -1 and retention time of 6 h. Energy consumption and mass transfer coefficient of the reactions were calculated. The continuous flow reactor performed better than batch reactor with reference to energy consumption and economy. The overall treatment cost for complete COD removal of real textile wastewater was 5.83 USD m -3 . Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism

    Yue, Ning J.

    2008-01-01

    As different types of radionuclides (e.g., 131 Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically used for years, such as 125 I and 103 Pd, the sources have been manufactured and marketed by several vendors with different designs and structures. Because of the nature of emission of low energy photons for these radionuclides, energy spectra of the sources are very dependent on their individual designs. Though values of the HVL or the TVL in certain commonly used shielding materials are relatively small for these low energy photon emitting sources, the question remains how the variations in energy spectra affect the HVL (or TVL) values and whether these values can be calculated with a relatively simple method. A more fundamental question is whether a method can be established to derive the HVL (TVL) values for any brachytherapy sources and for different materials in a relatively straightforward fashion. This study was undertaken to answer these questions. Based on energy spectra, a well established semiempirical mass attenuation coefficient computing scheme was utilized to derive the HVL (TVL) values of different materials for different types of brachytherapy sources. The method presented in this study may be useful to estimate HVL (TVL) values of different materials for brachytherapy sources of different designs and containing different radionuclides

  16. Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation

    Chang, Hing-Chiu; Juan, Chun-Jung; Hsu, Hsian-He; Chiu, Hui-Chu; Cheng, Cheng-Chieh; Chiu, Su-Chin; Liu, Yi-Jui; Chung, Hsiao-Wen

    2014-01-01

    To establish standard apparent diffusion coefficient (ADC) and the fat content as a function of age, gender and body mass index (BMI) in healthy parotid glands, and to address the influences of fat suppression on ADC measurements. A total of 100 healthy adults (gender and age evenly distributed) were prospectively recruited, with parotid fat content measured from gradient-echo images with fat-water separated using iterative decomposition with echo asymmetry and least squares (IDEAL). The ADCs were estimated using both fat-saturated and non-fat-saturated diffusion-weighted imaging via a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique. Parotid fat content was larger in men than in women by about 10 percentage points (P < 0.005), and positively associated with BMI and age for both genders (mostly with P < 0.001). ADCs estimated with non-fat-saturated PROPELLER were significantly lower in men than in women (P < 0.005), but showed no gender difference if measured using fat-saturated PROPELLER (P = 0.840). The negative association between parotid ADC and age/BMI/fat (P < 0.001) showed greater regression slopes in non-fat-saturated PROPELLER than in fat-saturated data. Parotid fat content in healthy adults correlates positively with both age and BMI; the correlation with age is gender-dependent. Parotid ADC measurements are strongly influenced by fat saturation. (orig.)

  17. Magnetic resonance imaging findings of the lumbar spine in elite horseback riders: correlations with back pain, body mass index, trunk/leg-length coefficient, and riding discipline.

    Kraft, Clayton N; Pennekamp, Peter H; Becker, Ute; Young, Mei; Diedrich, Oliver; Lüring, Christian; von Falkenhausen, Makus

    2009-11-01

    Most orthopaedic problems experienced by competitive horseback riders are related to pain in the lower back, hip joint, and hamstring muscles. Riders-especially, show jumpers-are frequently hampered in their performance because of lumbar pain. To date, there has been no research into lumbar disk degeneration in elite competitive riders. Competitive horseback riding accelerates lumbar disk degeneration. Cross-sectional study; Level of evidence, 3. Fifty-eight elite riders (18 men, 40 women; mean age, 32.4 years) and a control group of 30 nonriding volunteers (17 men, 13 women; mean age, 28.7 years) were evaluated for lumbar disk degeneration, cross-sectional area of paraspinal muscles, spondylolysis, and spondylolisthesis, using magnetic resonance imaging (MRI). The prevalence of disk degeneration between the 2 groups was compared, and the relationship was investigated between low back pain (LBP), riding discipline, body mass index (BMI), trunk/leg-length coefficient, and MRI results. Eighty-eight percent of elite riders (n = 51) had a history of LBP, versus 33% of the controls (P back pain. Although riders have a high prevalence of LBP, there is no conclusive MRI evidence to suggest that the cause lies in undue disk degeneration, spondylolysis, spondylolisthesis, or pathologic changes of the paraspinal muscles of the lumbar spine.

  18. Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation

    Chang, Hing-Chiu [National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Duke University Medical Center, Brain Imaging and Analysis Center, Durham, NC (United States); GE Healthcare, Applied Science Laboratory, Taipei (China); Juan, Chun-Jung; Hsu, Hsian-He [National Defense Medical Center, Department of Radiology, Taipei (China); Tri-Service General Hospital, Department of Radiology, Taipei (China); Chiu, Hui-Chu [Tatung University, Graduate Institute of Design Science, Taipei (China); Cheng, Cheng-Chieh; Chiu, Su-Chin [National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Liu, Yi-Jui [Feng Chia University, Department of Automatic Control Engineering, Taichung (China); Chung, Hsiao-Wen [National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Tri-Service General Hospital, Department of Radiology, Taipei (China); National Taiwan University, MD.624, Department of Electrical Engineering, Taipei (China)

    2014-09-15

    To establish standard apparent diffusion coefficient (ADC) and the fat content as a function of age, gender and body mass index (BMI) in healthy parotid glands, and to address the influences of fat suppression on ADC measurements. A total of 100 healthy adults (gender and age evenly distributed) were prospectively recruited, with parotid fat content measured from gradient-echo images with fat-water separated using iterative decomposition with echo asymmetry and least squares (IDEAL). The ADCs were estimated using both fat-saturated and non-fat-saturated diffusion-weighted imaging via a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique. Parotid fat content was larger in men than in women by about 10 percentage points (P < 0.005), and positively associated with BMI and age for both genders (mostly with P < 0.001). ADCs estimated with non-fat-saturated PROPELLER were significantly lower in men than in women (P < 0.005), but showed no gender difference if measured using fat-saturated PROPELLER (P = 0.840). The negative association between parotid ADC and age/BMI/fat (P < 0.001) showed greater regression slopes in non-fat-saturated PROPELLER than in fat-saturated data. Parotid fat content in healthy adults correlates positively with both age and BMI; the correlation with age is gender-dependent. Parotid ADC measurements are strongly influenced by fat saturation. (orig.)

  19. Effects of alcohols on gas holdup and volumetric liquid-phase mass transfer coefficient in gel-particle-suspended bubble column

    Salvacion, J.; Murayama, M.; Otaguchi, K.; Koide, K. [Tokyo Institute of Technology, Tokyo (Japan)

    1995-08-20

    The effects of alcohols, column dimensions, gas velocity, physical properties of liquids, and gel particles on the gas holdup e{sub G} and the volumetric liquid-phase mass transfer coefficient k{sub L}a in a gel-particle-suspended bubble column under liquid-solid batch operation were studied experimentally. It was shown that addition of at alcohols to water generally increases e{sub G}. However, k{sub L}a values in aqueous solutions of alcohols became larger or smaller than those in water, according to the kind and concentration of the alcohol added to water. It was also shown that the presence of suspended gel-particles in the bubble column reduces values of e{sub G} and k{sub L}a. Based on these observations, empirical equations for e{sub G} in the transition regime in an ethanol solution, for e{sub G} in the heterogeneous now regime applicable to various alcohol solutions and for k{sub L}a in both now regimes were proposed. 18 refs., 12 figs., 3 tabs.

  20. Self-absorption corrections for well-type germanium detectors

    Appleby, P.G.; Richardson, N.; Nolan, P.J.

    1992-01-01

    Corrections for self-absorption are of vital importance to accurate determination by gamma spectrometry of radionuclides such as 210 Pb, 241 Am and 234 Th which emit low energy gamma radiation. A simple theoretical model for determining the necessary corrections for well-type germanium detectors is presented. In this model, self-absorption factors are expressed in terms of the mass attenuation coefficient of the sample and a parameter characterising the well geometry. Experimental measurements of self-absorption are used to evaluate the model and to determine a semi-empirical algorithm for improved estimates of the geometrical parameter. (orig.)

  1. CONFIRMATION OF ENHANCED DWARF-SENSITIVE ABSORPTION FEATURES IN THE SPECTRA OF MASSIVE ELLIPTICAL GALAXIES: FURTHER EVIDENCE FOR A NON-UNIVERSAL INITIAL MASS FUNCTION

    Van Dokkum, Pieter G.; Conroy, Charlie

    2011-01-01

    We recently found that massive cluster elliptical galaxies have strong Na I λ8183, 8195 and FeH λ9916 Wing-Ford band absorption, indicating the presence of a very large population of stars with masses ∼ sun . Here we test this result by comparing the elliptical galaxy spectra to those of luminous globular clusters associated with M31. These globular clusters have similar metallicities, abundance ratios, and ages as massive elliptical galaxies but their low dynamical mass-to-light ratios rule out steep stellar initial mass functions (IMFs). From high-quality Keck spectra we find that the dwarf-sensitive absorption lines in globular clusters are significantly weaker than in elliptical galaxies and consistent with normal IMFs. The differences in the Na I and Wing-Ford indices are 0.027 ± 0.007 mag and 0.017 ± 0.006 mag, respectively. We directly compare the two classes of objects by subtracting the averaged globular cluster spectrum from the averaged elliptical galaxy spectrum. The difference spectrum is well fit by the difference between a stellar population synthesis model with a bottom-heavy IMF and one with a bottom-light IMF. We speculate that the slope of the IMF may vary with velocity dispersion, although it is not yet clear what physical mechanism would be responsible for such a relation.

  2. Simultaneous mass transfer of H2S and CO2 with complex chemical reactions in an aqueous di-isopropanolamine solution = Gleichzeitige absorption von H2S und CO2 in Wässriger Di-isopropanolaminlösung

    Blauwhoff, P.M.M.; van Swaaij, Willibrordus Petrus Maria

    1985-01-01

    The absorption of H2S and CO2 into an aqueous di-isopropanolamine (DIPA) solution was studied experimentally and theoretically as an example of simultaneous mass transfer with complex reversible reactions. The absorption phenomena were classified into three regimes: (1) negligible mutual interaction

  3. A Java-platform software for the evaluation of mass attenuation and ...

    A computer software was written for the evaluation of mass attenuation coefficient (μ/ρ) and mass energy-absorption coefficient (μ /ρ) for body tissues and substitutes of arbitrary elemental composition and en percentage-by-weight of elemental constituents using the Java development platform which could run on any ...

  4. Perdas endógenas e coeficientes de absorção aparente e real do magnésio em caprinos Endogenous losses and coefficients of apparent and true absorption of magnesium in goats

    Claudete Regina Alcalde

    1999-01-01

    (AN and Saanen (SN goat breeds. Twelve kids, six of each breed, with average 19.8 kg LW, were used. Semipurified diets (low Mg content based on cracked rice, corn gluten meal and cellulose were supplemented with MgO to obtain the levels of .05 (without supplementation, .20 and .35% of Mg (% DM. The levels of Mg affected the coefficient of apparent absorption of Mg and Ca, with average values of 57.8, 73.9, and 73.2% for Mg and 55.7, 39.6 and 49.5% for Ca for diets with .05, .20, and .35% Mg, respectively. However, there was no effect of the dietary Mg level on the coefficient of apparent absorption of P, Na and K. An interaction between Mg level and breeds was observed for the real absorption of Mg. The mean for AN breed, on the level .05% Mg was 61.0% and for the levels 0.20 and 0.35% Mg, 77.2 and 73.2%, respectively. However, for SN breed the means were 73.3, 75.5 and 76.0%, for the same levels, without differences. The digestibility of dry matter, crude protein, and nitrogen free extract decreased with the crescent dietary Mg level. The fecal (7.0, 20.8 and 34.4 mg/kg LW0.75.d and urinary (3.9, 30.8 and 44.6 mg/kg LW0.75.d Mg excretion increased with the crescent dietary Mg level. There was also influence of the dietary Mg level on the blood serum Mg concentration (1.74, 2.23 and 2.80 mg/dL for .05, .20, and .35% Mg, respectively.

  5. Implementation of suitable flow injection/sequential-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    Hansen, Elo Harald; Wang, Jianhua

    2002-01-01

    Various preconditioning procedures encomprising appropriate separation/preconcentration schemes in order to obtain optimal sensitivity and selectivity characteristics when using electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS...

  6. Effect of size and indium-composition on linear and nonlinear optical absorption of InGaN/GaN lens-shaped quantum dot

    Jbara, Ahmed S; Othaman, Zulkafli; Saeed, M A

    2016-01-01

    Based on the Schrödinger equation for envelope function in the effective mass approximation, linear and nonlinear optical absorption coefficients in a multi-subband lens quantum dot are investigated. The effects of quantum dot size on the interband and intraband transitions energy are also analyzed. The finite element method is used to calculate the eigenvalues and eigenfunctions. Strain and In-mole-fraction effects are also studied, and the results reveal that with the decrease of the In-mole fraction, the amplitudes of linear and nonlinear absorption coefficients increase. The present computed results show that the absorption coefficients of transitions between the first excited states are stronger than those of the ground states. In addition, it has been found that the quantum dot size affects the amplitudes and peak positions of linear and nonlinear absorption coefficients while the incident optical intensity strongly affects the nonlinear absorption coefficients. (paper)

  7. Gamma ray attenuation coefficient measurement for neutron-absorbent materials

    Jalali, Majid; Mohammadi, Ali

    2008-01-01

    The compounds Na 2 B 4 O 7 , H 3 BO 3 , CdCl 2 and NaCl and their solutions attenuate gamma rays in addition to neutron absorption. These compounds are widely used in the shielding of neutron sources, reactor control and neutron converters. Mass attenuation coefficients of gamma related to the four compounds aforementioned, in energies 662, 778.9, 867.38, 964.1, 1085.9, 1173, 1212.9, 1299.1,1332 and 1408 keV, have been determined by the γ rays transmission method in a good geometry setup; also, these coefficients were calculated by MCNP code. A comparison between experiments, simulations and Xcom code has shown that the study has potential application for determining the attenuation coefficient of various compound materials. Experiment and computation show that H 3 BO 3 with the lowest average Z has the highest gamma ray attenuation coefficient among the aforementioned compounds

  8. Mass spectrometric methods for studying nutrient mineral and trace element absorption and metabolism in humans using stable isotopes: a review

    Crews, H.M.; Eagles, J.; Mellon, F.A.; Luten, J.B.; McGaw, B.A.

    1994-01-01

    Mass spectrometric methods for determining stable isotopes of nutrient minerals and trace elements in human metabolic studies are described and discussed. The advantages and disadvantages of the techniques of electron ionization, fast atom bombardment, thermal ionization, and inductively coupled plasma and gas chromatography mass spectrometry are evaluated with reference to their accuracy, precision, sensitivity, and convenience, and the demands of human nutrition research. Examples of specific applications are described and the significance of current developments in mass spectrometry are discussed with reference to present and probable future research needs. (Author)

  9. Impurity profiling of liothyronine sodium by means of reversed phase HPLC, high resolution mass spectrometry, on-line H/D exchange and UV/Vis absorption.

    Ruggenthaler, M; Grass, J; Schuh, W; Huber, C G; Reischl, R J

    2017-09-05

    For the first time, a comprehensive investigation of the impurity profile of the synthetic thyroid API (active pharmaceutical ingredient) liothyronine sodium (LT 3 Na) was performed by using reversed phase HPLC and advanced structural elucidation techniques including high resolution tandem mass spectrometry (HRMS/MS) and on-line hydrogen-deuterium (H/D) exchange. Overall, 39 compounds were characterized and 25 of these related substances were previously unknown to literature. The impurity classification system recently developed for the closely related API levothyroxine sodium (LT 4 Na) could be applied to the newly characterized liothyronine sodium impurities resulting in a wholistic thyroid API impurity classification system. Furthermore, the mass-spectrometric CID-fragmentation of specific related substances was discussed and rationalized by detailed fragmentation pathways. Moreover, the UV/Vis absorption characteristics of the API and selected impurities were investigated to corroborate chemical structure assignments derived from MS data. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Effect of internal pressure and gas/liquid interface area on the CO mass transfer coefficient using hollow fibre membranes as a high mass transfer gas diffusing system for microbial syngas fermentation.

    Yasin, Muhammad; Park, Shinyoung; Jeong, Yeseul; Lee, Eun Yeol; Lee, Jinwon; Chang, In Seop

    2014-10-01

    This study proposed a submerged hollow fibre membrane bioreactor (HFMBR) system capable of achieving high carbon monoxide (CO) mass transfer for applications in microbial synthesis gas conversion systems. Hydrophobic polyvinylidene fluoride (PVDF) membrane fibres were used to fabricate a membrane module, which was used for pressurising CO in water phase. Pressure through the hollow fibre lumen (P) and membrane surface area per unit working volume of the liquid (A(S)/V(L)) were used as controllable parameters to determine gas-liquid volumetric mass transfer coefficient (k(L)a) values. We found a k(L)a of 135.72 h(-1) when P was 93.76 kPa and AS/VL was fixed at 27.5m(-1). A higher k(L)a of 155.16 h(-1) was achieved by increasing AS/VL to 62.5m(-1) at a lower P of 37.23 kPa. Practicality of HFMBR to support microbial growth and organic product formation was assessed by CO/CO2 fermentation using Eubacterium limosum KIST612. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. The COS/UVES absorption survey of the Magellanic stream. III. Ionization, total mass, and inflow rate onto the Milky Way

    Fox, Andrew J.; Thom, Christopher; Tumlinson, Jason; Ely, Justin; Kumari, Nimisha; Wakker, Bart P.; Hernandez, Audra K.; Haffner, L. Matthew; Barger, Kathleen A.; Lehner, Nicolas; Howk, J. Christopher; Richter, Philipp; Bland-Hawthorn, Joss; Charlton, Jane C.; Westmeier, Tobias; Misawa, Toru; Rodriguez-Hidalgo, Paola

    2014-01-01

    Dynamic interactions between the two Magellanic Clouds have flung large quantities of gas into the halo of the Milky Way. The result is a spectacular arrangement of gaseous structures, including the Magellanic Stream, the Magellanic Bridge, and the Leading Arm (collectively referred to as the Magellanic System). In this third paper of a series studying the Magellanic gas in absorption, we analyze the gas ionization level using a sample of 69 Hubble Space Telescope/Cosmic Origins Spectrograph sightlines that pass through or within 30° of the 21 cm emitting regions. We find that 81% (56/69) of the sightlines show UV absorption at Magellanic velocities, indicating that the total cross-section of the Magellanic System is ≈11,000 deg 2 , or around one-quarter of the entire sky. Using observations of the Si III/Si II ratio together with Cloudy photoionization modeling, we calculate the total gas mass (atomic plus ionized) of the Magellanic System to be ≈2.0 × 10 9 M ☉ (d/55 kpc) 2 , with the ionized gas contributing around three times as much mass as the atomic gas. This is larger than the current-day interstellar H I mass of both Magellanic Clouds combined, indicating that they have lost most of their initial gas mass. If the gas in the Magellanic System survives to reach the Galactic disk over its inflow time of ∼0.5-1.0 Gyr, it will represent an average inflow rate of ∼3.7-6.7 M ☉ yr –1 , potentially raising the Galactic star formation rate. However, multiple signs of an evaporative interaction with the hot Galactic corona indicate that the Magellanic gas may not survive its journey to the disk fully intact and will instead add material to (and cool) the corona.

  12. The COS/UVES absorption survey of the Magellanic stream. III. Ionization, total mass, and inflow rate onto the Milky Way

    Fox, Andrew J.; Thom, Christopher; Tumlinson, Jason; Ely, Justin; Kumari, Nimisha [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Wakker, Bart P.; Hernandez, Audra K.; Haffner, L. Matthew [Department of Astronomy, University of Wisconsin-Madison, 475 North Charter Street, Madison, WI 53706 (United States); Barger, Kathleen A.; Lehner, Nicolas; Howk, J. Christopher [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Richter, Philipp [Institut für Physik und Astronomie, Universität Potsdam, Haus 28, Karl-Liebknecht-Strasse 24/25, D-14476, Potsdam (Germany); Bland-Hawthorn, Joss [Institute of Astronomy, School of Physics, University of Sydney, Sydney, NSW 2006 (Australia); Charlton, Jane C. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Westmeier, Tobias [ICRAR, The University of Western Australia, 35 Stirling Highway, Crawley, WA 6009 (Australia); Misawa, Toru [School of General Education, Shinshu University, 3-1-1 Asahi, Matsumoto, Nagano 390-8621 (Japan); Rodriguez-Hidalgo, Paola, E-mail: afox@stsci.edu [Department of Physics and Astronomy, York University, 4700 Keele Street, Toronto, ON M3J 1P3 (Canada)

    2014-06-01

    Dynamic interactions between the two Magellanic Clouds have flung large quantities of gas into the halo of the Milky Way. The result is a spectacular arrangement of gaseous structures, including the Magellanic Stream, the Magellanic Bridge, and the Leading Arm (collectively referred to as the Magellanic System). In this third paper of a series studying the Magellanic gas in absorption, we analyze the gas ionization level using a sample of 69 Hubble Space Telescope/Cosmic Origins Spectrograph sightlines that pass through or within 30° of the 21 cm emitting regions. We find that 81% (56/69) of the sightlines show UV absorption at Magellanic velocities, indicating that the total cross-section of the Magellanic System is ≈11,000 deg{sup 2}, or around one-quarter of the entire sky. Using observations of the Si III/Si II ratio together with Cloudy photoionization modeling, we calculate the total gas mass (atomic plus ionized) of the Magellanic System to be ≈2.0 × 10{sup 9} M {sub ☉} (d/55 kpc){sup 2}, with the ionized gas contributing around three times as much mass as the atomic gas. This is larger than the current-day interstellar H I mass of both Magellanic Clouds combined, indicating that they have lost most of their initial gas mass. If the gas in the Magellanic System survives to reach the Galactic disk over its inflow time of ∼0.5-1.0 Gyr, it will represent an average inflow rate of ∼3.7-6.7 M {sub ☉} yr{sup –1}, potentially raising the Galactic star formation rate. However, multiple signs of an evaporative interaction with the hot Galactic corona indicate that the Magellanic gas may not survive its journey to the disk fully intact and will instead add material to (and cool) the corona.

  13. Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

    Aklamati, E K; Mulenga, M; Dueker, S R; Buchholz, B A; Peerson, J M; Kafwembe, E; Brown, K H; Haskell, M J

    2009-10-12

    A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children <5 y of age. To explore possible reasons for the lack of response to HD-VAS among Zambian children, we quantified the absorption, retention, and urinary elimination of either a single HDVAS (60 mg) or a smaller dose of stable isotope (SI)-labeled VA (5 mg), which was used to estimate VA pool size, in 3-4 y old Zambian boys (n = 4 for each VA dose). A 25 nCi tracer dose of [{sup 14}C{sub 2}]-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of {sup 14}C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting {sup 14}C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 {+-} 7.1%, 76.3 {+-} 6.7%, and 1.9 {+-} 0.6%/d, respectively, for the HD-VAS and 76.5 {+-} 9.5%, 71.1 {+-} 9.4%, and 1.8 {+-} 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

  14. Mass attenuation coefficient (μ/ρ), effective atomic number (Zeff) and measurement of x-ray energy spectra using based calcium phosphate biomaterials: a comparative study

    Fernandes Z, M. A.; Da Silva, T. A.; Nogueira, M. S.; Goncalves Z, E.

    2015-10-01

    In dentistry, alveolar bone regeneration procedures using based calcium phosphate biomaterials have been shown effective. However,there are not reports in the literature of studies the interaction of low energy radiation in these biomaterials used as attenuator and not being then allowed a comparison between the theoretical values and experimental.The objective of this study was to determine the interaction of radiation parameters of four dental biomaterials - BioOss, Cerasorb M Dental, Straumann Boneceramic and Osteogen for diagnostic radiology qualities. As a material and methods, the composition of the biomaterials was determined by the analytical techniques. The samples with 0.181 cm to 0,297 cm thickness were experimentally used as attenuators for the measurement of the transmitted X-rays spectra in X-ray equipment with 50 to 90 kV range by spectrometric system comprising the Cd Te detector. After this procedure, the mass attenuation coefficient, the effective atomic number were determined and compared between all the specimens analyzed, using the program WinXCOM in the range of 10 to 200 keV. In all strains examined observed that the energy spectrum of x-rays transmitted through the BioOss has the mean energy slightly smaller than the others biomaterials for close thickness. The μ/ρ and Z eff of the biomaterials showed its dependence on photon energy and atomic number of the elements of the material analyzed. It is concluded according to the methodology employed in this study that the measurements of x-ray spectrum, μ/ρ and Z eff using biomaterials as attenuators confirmed that the thickness, density, composition of the samples, the incident photon energy are factors that determine the characteristics of radiation in a tissue or equivalent material. (Author)

  15. Mass attenuation coefficients in the range 3.8⩽E⩽11 keV, K fluorescence yield and Kβ/Kα relative X-ray emission rate for Ti, V, Fe, Co, Ni, Cu and Zn measured with a tunable monochromatic X-ray source

    Ménesguen, Y.; Lépy, M.-C.

    2010-08-01

    This work presents new measurements of mass attenuation coefficients in the range 3.8⩽E⩽11 keV, K-absorption jump-ratios, Kα and Kβ fluorescence yields for Ti, V, Fe, Co, Ni, Cu and Zn. We use the experimental facility SOLEX, a tunable monochromatic X-ray source combined with an energy-dispersive high-purity germanium detector. The results are compared with theoretical values as well as with other experimental data and show a relatively good agreement. However, the derived K-jump-ratios appear larger than those widely used in the XCOM database. The Kα and Kβ fluorescence yields and the corresponding relative emission rates Kβ/Kα are also derived, which was made possible by the use of energy-dispersive detectors with good spectral resolution.

  16. Absorption and scattering coefficients estimation in two-dimensional participating media using the generalized maximum entropy and Levenberg-Marquardt methods; Estimacion del coeficiente de absorcion y dispersion en medios participantes bidimensionales utilizando el metodo de maxima entropia generalizada y el metodo Levenberg-Marquardt

    Berrocal T, Mariella J. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]|[Universidad Nacional de Ingenieria, Lima (Peru); Roberty, Nilson C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear; Silva Neto, Antonio J. [Universidade do Estado, Nova Friburgo, RJ (Brazil). Instituto Politecnico. Dept. de Engenharia Mecanica e Energia]|[Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2002-07-01

    The solution of inverse problems in participating media where there is emission, absorption and dispersion of the radiation possesses several applications in engineering and medicine. The objective of this work is to estimative the coefficients of absorption and dispersion in two-dimensional heterogeneous participating media, using in independent form the Generalized Maximum Entropy and Levenberg Marquardt methods. Both methods are based on the solution of the direct problem that is modeled by the Boltzmann equation in cartesian geometry. Some cases testes are presented. (author)

  17. Quasinormal modes, stability analysis and absorption cross section for 4-dimensional topological Lifshitz black hole

    Gonzalez, P.A.; Moncada, Felipe; Vasquez, Yerko

    2012-01-01

    We study scalar perturbations in the background of a topological Lifshitz black hole in four dimensions. We compute analytically the quasinormal modes and from these modes we show that topological Lifshitz black hole is stable. On the other hand, we compute the reflection and transmission coefficients and the absorption cross section and we show that there is a range of modes with high angular momentum which contributes to the absorption cross section in the low frequency limit. Furthermore, in this limit, we show that the absorption cross section decreases if the scalar field mass increases, for a real scalar field mass. (orig.)

  18. Quasinormal modes, stability analysis and absorption cross section for 4-dimensional topological Lifshitz black hole

    Gonzalez, P.A. [Universidad Central de Chile, Escuela de Ingenieria Civil en Obras Civiles, Facultad de Ciencias Fisicas y Matematicas, Santiago (Chile); Universidad Diego Portales, Santiago (Chile); Moncada, Felipe; Vasquez, Yerko [Universidad de La Frontera, Departamento de Ciencias Fisicas, Facultad de Ingenieria, Ciencias y Administracion, Temuco (Chile)

    2012-12-15

    We study scalar perturbations in the background of a topological Lifshitz black hole in four dimensions. We compute analytically the quasinormal modes and from these modes we show that topological Lifshitz black hole is stable. On the other hand, we compute the reflection and transmission coefficients and the absorption cross section and we show that there is a range of modes with high angular momentum which contributes to the absorption cross section in the low frequency limit. Furthermore, in this limit, we show that the absorption cross section decreases if the scalar field mass increases, for a real scalar field mass. (orig.)

  19. Mass

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  20. Optical absorption measurement system

    Draggoo, V.G.; Morton, R.G.; Sawicki, R.H.; Bissinger, H.D.

    1989-01-01

    This patent describes a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature

  1. A varying coefficient model to measure the effectiveness of mass media anti-smoking campaigns in generating calls to a Quitline.

    Bui, Quang M; Huggins, Richard M; Hwang, Wen-Han; White, Victoria; Erbas, Bircan

    2010-01-01

    Anti-smoking advertisements are an effective population-based smoking reduction strategy. The Quitline telephone service provides a first point of contact for adults considering quitting. Because of data complexity, the relationship between anti-smoking advertising placement, intensity, and time trends in total call volume is poorly understood. In this study we use a recently developed semi-varying coefficient model to elucidate this relationship. Semi-varying coefficient models comprise parametric and nonparametric components. The model is fitted to the daily number of calls to Quitline in Victoria, Australia to estimate a nonparametric long-term trend and parametric terms for day-of-the-week effects and to clarify the relationship with target audience rating points (TARPs) for the Quit and nicotine replacement advertising campaigns. The number of calls to Quitline increased with the TARP value of both the Quit and other smoking cessation advertisement; the TARP values associated with the Quit program were almost twice as effective. The varying coefficient term was statistically significant for peak periods with little or no advertising. Semi-varying coefficient models are useful for modeling public health data when there is little or no information on other factors related to the at-risk population. These models are well suited to modeling call volume to Quitline, because the varying coefficient allowed the underlying time trend to depend on fixed covariates that also vary with time, thereby explaining more of the variation in the call model.

  2. Influence of the particle size dispersion on gamma-raidation absorption

    Bonchev, Ts.; Amin, S.S.

    1985-01-01

    The dependence of the value of the Moessbauer absorption on the patricle size of the absorbing material was investigated. It was assumed that: a) the investigated substance is with homogenious composition and that it consists of spherical particles; b) the particles are considered to be uniformly distributed in a matter practically negligible mass-absorption coefficient. The experiment was performed by using X-rays of Ni and Cu generated by the 14,4125 KeV resonance radiation of 57 Co

  3. Hopping absorption edge in silicon inversion layers

    Kostadinov, I.Z.

    1983-09-01

    The low frequency gap observed in the absorption spectrum of silicon inversion layers is related to the AC variable range hopping. The frequency dependence of the absorption coefficient is calculated. (author)

  4. Perturbative determination of mass-dependent renormalization and improvement coefficients for the heavy-light vector and axial-vector currents with relativistic heavy and domain-wall light quarks

    Yamada, Norikazu; Aoki, Sinya; Kuramashi, Yoshinobu

    2005-01-01

    We determine the mass-dependent renormalization as well as improvement coefficients for the heavy-light vector and axial-vector currents consisting of the relativistic heavy and the domain-wall light quarks through the standard matching procedure. The calculation is carried out perturbatively at the one-loop level to remove the systematic error of O(α s (am Q ) n ap) as well as O(α s (am Q ) n ) (n>=0), where p is a typical momentum scale in the heavy-light system. We point out that renormalization and improvement coefficients of the heavy-light vector current agree with those of the axial-vector current, thanks to the exact chiral symmetry for the light quark. The results obtained with three different gauge actions, plaquette, Iwasaki and DBW2, are presented as a function of heavy quark mass and domain-wall height

  5. Mass attenuation coefficient of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using 16.59 – 25.26 keV photon energy range

    Mohd Yusof, Mohd Fahmi; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz; Bauk, Sabar; Hashim, Rokiah

    2015-01-01

    The Rhizophora spp. particleboards were fabricated using ≤ 104 µm particle size at three different fabrication methods; binderless, steam pre-treated and tannin-added. The mass attenuation coefficient of Rhizophora spp. particleboards were measured using x-ray fluorescent (XRF) photon from niobium, molybdenum, palladium, silver and tin metal plates that provided photon energy between 16.59 to 25.26 keV. The results were compared to theoretical values for water calculated using photon cross-section database (XCOM).The results showed that all Rhizophora spp. particleboards having mass attenuation coefficient close to calculated XCOM for water. Tannin-added Rizophora spp. particleboard was nearest to calculated XCOM for water with χ2 value of 13.008 followed by binderless Rizophora spp. (25.859) and pre-treated Rizophora spp. (91.941)

  6. Mass attenuation coefficient of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using 16.59 – 25.26 keV photon energy range

    Mohd Yusof, Mohd Fahmi, E-mail: mfahmi@usm.my; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz [School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Bauk, Sabar [School of Distance Education, Universiti Sains Malaysia, 11800 Penang (Malaysia); Hashim, Rokiah [School of Industrial Technologies, Universiti Sains Malaysia, 11800 Penang (Malaysia)

    2015-04-29

    The Rhizophora spp. particleboards were fabricated using ≤ 104 µm particle size at three different fabrication methods; binderless, steam pre-treated and tannin-added. The mass attenuation coefficient of Rhizophora spp. particleboards were measured using x-ray fluorescent (XRF) photon from niobium, molybdenum, palladium, silver and tin metal plates that provided photon energy between 16.59 to 25.26 keV. The results were compared to theoretical values for water calculated using photon cross-section database (XCOM).The results showed that all Rhizophora spp. particleboards having mass attenuation coefficient close to calculated XCOM for water. Tannin-added Rizophora spp. particleboard was nearest to calculated XCOM for water with χ2 value of 13.008 followed by binderless Rizophora spp. (25.859) and pre-treated Rizophora spp. (91.941)

  7. A fast neutron and dual-energy gamma-ray absorption method (NEUDEG) for investigating materials using a 252Cf source

    Bartle, C. Murray

    2014-01-01

    DEXA (dual-energy X-ray absorption) is widely used in airport scanners, industrial scanners and bone densitometers. DEXA determines the properties of materials by measuring the absorption differences of X-rays from a bremsstrahlung tube source with and without filtering. Filtering creates a beam with a higher mean energy, which causes lower material absorption. The absorption difference between measurements (those with a filter subtracted from those without a filter) is a positive number that increases with the effective atomic number of the material. In this paper, the concept of using a filter to create a dual beam and an absorption difference in materials is applied to radiation from a 252 Cf source, called NEUDEG (neutron and dual-energy gamma absorption). NEUDEG includes absorptions for fast neutrons as well as the dual photon beams and thus an incentive for developing the method is that, unlike DEXA, it is inherently sensitive to the hydrogen content of materials. In this paper, a model for the absorption difference and absorption sum in NEUDEG is presented using the combined gamma ray and fast neutron mass attenuation coefficients. Absorption differences can be either positive or negative in NEUDEG, increasing with increases in the effective atomic number and decreasing with increases in the hydrogen content. Sample sets of absorption difference curves are calculated for materials with typical gamma-ray and fast neutron mass attenuation coefficients. The model, which uses tabulated mass attenuated coefficients, agrees with experimental data for porcelain tiles and polyethylene sheets. The effects of “beam hardening” are also investigated. - Highlights: • Creation of a dual neutron/gamma beam from 252 Cf is described. • An absorption model is developed using mass attenuation coefficients. • A graphical method is used to show sample results from the model. • The model is successfully compared with experimental results. • The importance of

  8. Cu determination in crude oil distillation products by atomic absorption and inductively coupled plasma mass spectrometry after analyte transfer to aqueous solution

    Kowalewska, Zofia; Ruszczynska, Anna; Bulska, Ewa

    2005-01-01

    Cu was determined in a wide range of petroleum products from crude oil distillation using flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS). Different procedures of sample preparation were evaluated: (i) mineralization with sulfuric acid in an open system (ii) mineralization in a closed microwave system (iii) combustion in hydrogen-oxygen flame in the Wickbold's apparatus (iv) matrix evaporation followed by acid dissolution, and (v) acidic extraction. All the above procedures led to the transfer of the analyte into an aqueous solution for the analytical measurement step. It was found that application of FAAS was limited to the analysis of the heaviest petroleum products of high Cu content. In ICP-MS, the use of internal reference method (with Rh or In as internal reference element) was required to eliminate the matrix effects in the analysis of extracts and the concentrated solutions of mineralized heavy petroleum products. The detection limits (in original samples) were equal to, respectively, 10, 86, 3.3, 0.9 and 0.4 ng g -1 in procedures i-v with ETAAS detection and 10, 78, 1.1 and 0.5 ng g -1 in procedures i-iii and v with ICP-MS detection. The procedures recommended here were validated by recovery experiments, certified reference materials analysis and comparison of results, obtained for a given sample, in different ways. The Cu content in the analyzed samples was: 50-110 ng g -1 in crude oil, -1 in gasoline, -1 in atmospheric oil, -1 in heavy vacuum oil and 140-300 ng g -1 in distillation residue

  9. Cu determination in crude oil distillation products by atomic absorption and inductively coupled plasma mass spectrometry after analyte transfer to aqueous solution

    Kowalewska, Zofia; Ruszczyńska, Anna; Bulska, Ewa

    2005-03-01

    Cu was determined in a wide range of petroleum products from crude oil distillation using flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS). Different procedures of sample preparation were evaluated: (i) mineralization with sulfuric acid in an open system, (ii) mineralization in a closed microwave system, (iii) combustion in hydrogen-oxygen flame in the Wickbold's apparatus, (iv) matrix evaporation followed by acid dissolution, and (v) acidic extraction. All the above procedures led to the transfer of the analyte into an aqueous solution for the analytical measurement step. It was found that application of FAAS was limited to the analysis of the heaviest petroleum products of high Cu content. In ICP-MS, the use of internal reference method (with Rh or In as internal reference element) was required to eliminate the matrix effects in the analysis of extracts and the concentrated solutions of mineralized heavy petroleum products. The detection limits (in original samples) were equal to, respectively, 10, 86, 3.3, 0.9 and 0.4 ng g - 1 in procedures i-v with ETAAS detection and 10, 78, 1.1 and 0.5 ng g - 1 in procedures i-iii and v with ICP-MS detection. The procedures recommended here were validated by recovery experiments, certified reference materials analysis and comparison of results, obtained for a given sample, in different ways. The Cu content in the analyzed samples was: 50-110 ng g - 1 in crude oil, oil, oil and 140-300 ng g - 1 in distillation residue.

  10. Brown carbon absorption in the red and near-infrared spectral region

    Hoffer, András; Tóth, Ádám; Pósfai, Mihály; Eddy Chung, Chul; Gelencsér, András

    2017-06-01

    Black carbon (BC) aerosols have often been assumed to be the only light-absorbing carbonaceous particles in the red and near-infrared spectral regions of solar radiation in the atmosphere. Here we report that tar balls (a specific type of organic aerosol particles from biomass burning) do absorb red and near-infrared radiation significantly. Tar balls were produced in a laboratory experiment, and their chemical and optical properties were measured. The absorption of these particles in the range between 470 and 950 nm was measured with an aethalometer, which is widely used to measure atmospheric aerosol absorption. We find that the absorption coefficient of tar balls at 880 nm is more than 10 % of that at 470 nm. The considerable absorption of red and infrared light by tar balls also follows from their relatively low absorption Ångström coefficient (and significant mass absorption coefficient) in the spectral range between 470 and 950 nm. Our results support the previous finding that tar balls may play an important role in global warming. Due to the non-negligible absorption of tar balls in the near-infrared region, the absorption measured in the field at near-infrared wavelengths cannot solely be due to soot particles.

  11. MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl Detector and Comparison with XCOM and Monte Carlo Data

    Huseyin Ozan Tekin

    2016-01-01

    Full Text Available Gamma-ray measurements in various research fields require efficient detectors. One of these research fields is mass attenuation coefficients of different materials. Apart from experimental studies, the Monte Carlo (MC method has become one of the most popular tools in detector studies. An NaI(Tl detector has been modeled, and, for a validation study of the modeled NaI(Tl detector, the absolute efficiency of 3 × 3 inch cylindrical NaI(Tl detector has been calculated by using the general purpose Monte Carlo code MCNP-X (version 2.4.0 and compared with previous studies in literature in the range of 661–2620 keV. In the present work, the applicability of MCNP-X Monte Carlo code for mass attenuation of concrete sample material as building material at photon energies 59.5 keV, 80 keV, 356 keV, 661.6 keV, 1173.2 keV, and 1332.5 keV has been tested by using validated NaI(Tl detector. The mass attenuation coefficients of concrete sample have been calculated. The calculated results agreed well with experimental and some other theoretical results. The results specify that this process can be followed to determine the data on the attenuation of gamma-rays with other required energies in other materials or in new complex materials. It can be concluded that data from Monte Carlo is a strong tool not only for efficiency studies but also for mass attenuation coefficients calculations.

  12. Attenuation coefficients of soils

    Martini, E.; Naziry, M.J.

    1989-01-01

    As a prerequisite to the interpretation of gamma-spectrometric in situ measurements of activity concentrations of soil radionuclides the attenuation of 60 to 1332 keV gamma radiation by soil samples varying in water content and density has been investigated. A useful empirical equation could be set up to describe the dependence of the mass attenuation coefficient upon photon energy for soil with a mean water content of 10%, with the results comparing well with data in the literature. The mean density of soil in the GDR was estimated at 1.6 g/cm 3 . This value was used to derive the linear attenuation coefficients, their range of variation being 10%. 7 figs., 5 tabs. (author)

  13. Organic aerosols and inorganic species from post-harvest agricultural-waste burning emissions over northern India: impact on mass absorption efficiency of elemental carbon.

    Rajput, Prashant; Sarin, M M; Sharma, Deepti; Singh, Darshan

    2014-01-01

    Atmospheric PM2.5 (particulate matter with aerodynamic diameter of ≤ 2.5 μm), collected from a source region [Patiala: 30.2 °N; 76.3 °E; 250 m above mean sea level] of emissions from post-harvest agricultural-waste (paddy-residue) burning in the Indo-Gangetic Plain (IGP), North India, has been studied for its chemical composition and impact on regional atmospheric radiative forcing. On average, organic aerosol mass accounts for 63% of PM2.5, whereas the contribution of elemental carbon (EC) is ∼3.5%. Sulphate, nitrate and ammonium contribute up to ∼85% of the total water-soluble inorganic species (WSIS), which constitutes ∼23% of PM2.5. The potassium-to-organic carbon ratio from paddy-residue burning emissions (KBB(+)/OC: 0.05 ± 0.01) is quite similar to that reported from Amazonian and Savanna forest-fires; whereas non-sea-salt-sulphate-to-OC ratio (nss-SO4(2-)/OC: 0.21) and nss-SO4(2-)/EC ratio of 2.6 are significantly higher (by factor of 5 to 8). The mass absorption efficiency of EC (3.8 ± 1.3 m(2) g(-1)) shows significant decrease with a parallel increase in the concentrations of organic aerosols and scattering species (sulphate and nitrate). A cross plot of OC/EC and nss-SO4(2-)/EC ratios show distinct differences for post-harvest burning emissions from paddy-residue as compared to those from fossil-fuel combustion sources in south-east Asia.

  14. A drying coefficient for building materials

    Scheffler, Gregor Albrecht; Plagge, Rudolf

    2009-01-01

    coefficient is defined which can be determined based on measured drying data. The correlation of this coefficient with the water absorption and the vapour diffusion coefficient is analyzed and its additional information content is critically challenged. As result, a drying coefficient has been derived......The drying experiment is an important element of the hygrothermal characterisation of building materials. Contrary to other moisture transport experiments as the vapour diffusion and the water absorption test, it is until now not possible to derive a simple coefficient for the drying. However......, in many cases such a coefficient would be highly appreciated, e.g. in interaction of industry and research or for the distinction and selection of suitable building materials throughout design and practise. This article first highlights the importance of drying experiments for hygrothermal...

  15. Biomarker- and similarity coefficient-based approaches to bacterial mixture characterization using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS).

    Zhang, Lin; Smart, Sonja; Sandrin, Todd R

    2015-11-05

    MALDI-TOF MS profiling has been shown to be a rapid and reliable method to characterize pure cultures of bacteria. Currently, there is keen interest in using this technique to identify bacteria in mixtures. Promising results have been reported with two- or three-isolate model systems using biomarker-based approaches. In this work, we applied MALDI-TOF MS-based methods to a more complex model mixture containing six bacteria. We employed: 1) a biomarker-based approach that has previously been shown to be useful in identification of individual bacteria in pure cultures and simple mixtures and 2) a similarity coefficient-based approach that is routinely and nearly exclusively applied to identification of individual bacteria in pure cultures. Both strategies were developed and evaluated using blind-coded mixtures. With regard to the biomarker-based approach, results showed that most peaks in mixture spectra could be assigned to those found in spectra of each component bacterium; however, peaks shared by two isolates as well as peaks that could not be assigned to any individual component isolate were observed. For two-isolate blind-coded samples, bacteria were correctly identified using both similarity coefficient- and biomarker-based strategies, while for blind-coded samples containing more than two isolates, bacteria were more effectively identified using a biomarker-based strategy.

  16. Medieval glass from the Cathedral in Paderborn: a comparative study using X-ray absorption spectroscopy, X-ray fluorescence, and inductively coupled laser ablation mass spectrometry

    Hormes, J. [University of Saskatchewan, Canadian Light Source Inc., Saskatoon, SK (Canada); Louisiana State University, CAMD, Baton Rouge, LA (United States); Roy, A.; Bovenkamp, G.L. [Louisiana State University, CAMD, Baton Rouge, LA (United States); Simon, K. [University of Goettingen, Geochemistry, Centre for Geosciences, Goettingen (Germany); Kim, C.Y. [University of Saskatchewan, Canadian Light Source Inc., Saskatoon, SK (Canada); Boerste, N. [Faculty for Theology Paderborn, Paderborn (Germany); Gai, S. [LWL - Archaeologie fuer Westfalen, Muenster (Germany)

    2013-04-15

    We have investigated four stained glass samples recovered from an archaeological excavation at the Cathedral in Paderborn (Germany) between 1978 and 1980. On two of the samples there are parts of paintings. Concentrations of major elements were determined using two independent techniques: LA-ICP-MS (a UV laser ablation microsampler combined with an inductively coupled plasma mass spectrometer) and synchrotron radiation X-ray excited X-ray fluorescence (SR-XRF). The SR-XRF data were quantified by using the program package PyMCA developed by the software group of the ESRF in Grenoble. Significant differences were found between the concentrations determined by the two techniques that can be explained by concentration gradients near the surface of the glasses caused, for example, by corrosion/leaching processes and the different surface sensitivities of the applied techniques. For several of the elements that were detected in the glass and in the colour pigments used for the paintings X-ray absorption near edge structure (XANES) spectra were recorded in order to determine the chemical speciation of the elements of interest. As was expected, most elements in the glass were found as oxides in their most stable form. Two notable exceptions were observed: titanium was not found as rutile - the most stable form of TiO{sub 2} - but in the form of anatase, and lead was not found in one defined chemical state but as a complex mixture of oxide, sulphate, and other compounds. (orig.)

  17. Ancient wood of the Acqualadrone rostrum: materials history through gas chromatography/mass spectrometry and sulfur X-ray absorption spectroscopy.

    Frank, Patrick; Caruso, Francesco; Caponetti, Eugenio

    2012-05-15

    In 2008 the rostrum from an ancient warship was recovered from the Mediterranean near Acqualadrone, Sicily. To establish its provenance and condition, samples of black and brown rostrum wood were examined using sulfur K-edge X-ray absorption spectroscopy (XAS) and gas chromatography/mass spectrometry (GC/MS). GC/MS of pyrolytic volatiles yielded only guaiacyl derivatives, indicating construction from pinewood. A derivatized extract of black wood yielded forms of abietic acid and sandaracopimaric acid consistent with pine pitch waterproofing. Numerical fits to the sulfur K-edge XAS spectra showed that about 65% of the endogenous sulfur consisted of thiols and disulfides. Elemental sulfur was about 2% and 7% in black and brown wood, respectively, while pyritic sulfur was about 12% and 6%. About 2% of the sulfur in both wood types was modeled as trimethylsulfonium, possibly reflecting biogenic (dimethylsulfonio)propionate. High-valent sulfur was exclusively represented by sulfate esters, consistent with bacterial sulfotransferase activity. Traces of chloride were detected, but no free sulfate ion. In summary, the rostrum was manufactured of pine wood and subsequently waterproofed with pine pitch. The subsequent 2300 years included battle, foundering, and marine burial followed by anoxia, bacterial colonization, sulfate reduction, and mobilization of transition metals, which produced pyrite and copious appended sulfur functionality.

  18. Real-time monitoring of respiratory absorption factors of volatile organic compounds in ambient air by proton transfer reaction time-of-flight mass spectrometry

    Huang, Zhonghui [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Yanli [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Center for Excellence in Urban Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China); Yan, Qiong [Department of Respiratory Diseases, Guangzhou No. 12 People' s Hospital, Guangzhou 510620 (China); Zhang, Zhou [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Wang, Xinming, E-mail: wangxm@gig.ac.cn [State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Center for Excellence in Urban Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China)

    2016-12-15

    Respiratory absorption factors (AFs) are essential parameters in the evaluation of human health risks from toxic volatile organic compounds (VOCs) in ambient air. A method for the real time monitoring of VOCs in inhaled and exhaled air by proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) has been developed to permit the calculation of respiratory AFs of VOCs. Isoprene was found to be a better breath tracer than O{sub 2}, CO{sub 2}, humidity, or acetone for distinguishing between the expiratory and inspiratory phases, and a homemade online breath sampling device with a buffer tube was used to optimize signal peak shapes. Preliminary tests with seven subjects exposed to aromatic hydrocarbons in an indoor environment revealed mean respiratory AFs of 55.0%, 55.9%, and 66.9% for benzene, toluene, and C8-aromatics (ethylbenzene and xylenes), respectively. These AFs were lower than the values of 90% or 100% used in previous studies when assessing the health risks of inhalation exposure to hazardous VOCs. The mean respiratory AFs of benzene, toluene and C8-aromatics were 66.5%, 70.2% and 82.3% for the three female subjects; they were noticeably much higher than that of 46.4%, 45.2% and 55.3%, respectively, for the four male subjects.

  19. Effect of sample thickness on the measured mass attenuation coefficients of some compounds and elements for 59.54, 661.6 and 1332.5 keV gamma-rays

    El-Rahman, M A; Abdel-Hady, Y L; Kamel, N

    2000-01-01

    Measurements have been made to determine gamma-rays attenuation coefficients very accurately by using an extremely narrow-collimated-beam transmission method. The effect of the sample thickness on the measured values of the mass attenuation coefficients (mu/rho) cm sup 2 /g of perspex, bakelite, paraffin, Al, Cu, Pb and Hg have been investigated at three different gamma-ray energies (59.54, 661.6 and 1332.5 keV). It is seen that for these chosen materials (mu/rho) remains constant in good agreement with the theoretical values up to 3 mean free paths and after that (mu/rho) values for Cu, Pb and Hg decrease with further increase in the absorber thickness. This result may be attributed to the increase in the number of coherent small-angle scattering photons which reach the detector.

  20. Laboratory-Scale Column Testing Using IONSIV IE-911 for Removing Cesium from Acidic Tank Waste Simulant. 2: Determination of Cesium Exchange Capacity and Effective Mass Transfer Coefficient from a 500-cm3 Column Experiment

    T.J. Tranter; R.D. Tillotson; T.A. Todd

    2005-01-01

    A semi-scale column test was performed using a commercial form of crystalline silicotitanate (CST) for removing radio-cesium from a surrogate acidic tank solution, which represents liquid waste stored at the Idaho National Engineering and Environmental Laboratory (INEEL). The engineered form of CST ion exchanger, known as IONSIVtmIE-911 (UOP, Mt. Laurel, NJ, USA), was tested in a 500-cm3 column to obtain a cesium breakthrough curve. The cesium exchange capacity of this column matched that obtained from previous testing with a 15-mc3 column. A numerical algorithm using implicit finite difference approximations was developed to solve the governing mass transport equations for the CST columns. An effective mass transfer coefficient was derived from solving these equations for previously reported 15 cm3 tests. The effective mass transfer coefficient was then used to predict the cesium breakthrough curve for the 500-cm3 column and compared to the experimental data reported in this paper. The calculated breakthrough curve showed excellent agreement with the data from the 500-cm3 column even though the interstitial velocity was a factor of two greater. Thus, this approach should provide a reasonable method for scale up to larger columns for treating actual tank waste

  1. Measurement of mass attenuation coefficients of Rhizophora spp. binderless particleboards in the 16.59-25.26 keV photon energy range and their density profile using x-ray computed tomography

    Marashdeh, M.W., E-mail: mwmarashdeh@yahoo.com [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Bauk, S. [Physics Section, P.P.P. Jarak Jauh, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Tajuddin, A.A. [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hashim, R. [Division of Bio-resource, Paper and Coatings Technology, School of Industrial Technology, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia)

    2012-04-15

    The mass attenuation coefficients of Rhizophora spp. binderless particleboard with four different particle sizes (samples A, B, C and D) and natural raw Rhizophora spp. wood (sample E) were determined using single-beam photon transmission in the energy range between 16.59 and 25.26 keV. This was done by determining the attenuation of K{sub {alpha}1} X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver and tin targets. The results were compared with theoretical values of young-age breast (Breast 1) and water calculated using a XCOM computer program. It was found that the mass attenuation coefficient of Rhizophora spp. binderless particleboards to be close to the calculated XCOM values in water than natural Rhizophora spp. wood. Computed tomography (CT) scans were then used to determine the density profile of the samples. The CT scan results showed that the Rhizophora spp. binderless particleboard has uniform density compared to natural Rhizophora spp. wood. In general, the differences in the variability of the profile density decrease as the particle size of the pellet samples decreases. - Highlights: Black-Right-Pointing-Pointer Mass attenuation coefficients were determined by X-ray fluorescent photons. Black-Right-Pointing-Pointer Sample with smaller particle size found very close to calculated water XCOM. Black-Right-Pointing-Pointer X-ray computed tomography scanner was used to investigate the density distribution. Black-Right-Pointing-Pointer The density distribution profile is improved with the decrease in the particle size. Black-Right-Pointing-Pointer Rhizophora spp. binderless particleboard could be used as phantom material.

  2. Comparison of mass transfer coefficient approach and Nernst-Planck formulation in the reactive transport modeling of Co, Ni, and Ag removal by mixed-bed ion-exchange resins

    Bachet, Martin; Jauberty, Loic; De Windt, Laurent; Dieuleveult, Caroline de; Tevissen, Etienne

    2014-01-01

    Experiments performed under chemical and flow conditions representative of pressurized water reactors (PWR) primary fluid purification by ion exchange resins (Amberlite IRN9882) are modeled with the OPTIPUR code, considering 1D reactive transport in the mixed-bed column with convective/dispersive transport between beads and electro-diffusive transport within the boundary film around the beads. The effectiveness of the purification in these dilute conditions is highly related to film mass transfer restrictions, which are accounted for by adjustment of a common mass transfer coefficient (MTC) on the experimental initial leakage or modeling of species diffusion through the bead film by the Nernst-Planck equation. A detailed analysis of the modeling against experimental data shows that the Nernst-Planck approach with no adjustable parameters performs as well as, or better than, the MTC approach, particularly to simulate the chromatographic elution of silver by nickel and the subsequent enrichment of the solution in the former metal. (authors)

  3. Measurements of mass-fraction activity coefficient at infinite dilution of aliphatic and aromatic hydrocarbons, thiophene, alcohols, water, ethers, and ketones in hyperbranched polymer, Boltorn H2004, using inverse gas chromatography

    Domanska, Urszula; Zolek-Tryznowska, Zuzanna

    2010-01-01

    Thermodynamic properties of the hyperbranched polymer, Boltorn H2004 (B-H2004), were investigated by inverse gas chromatography with 42 different solvents: n-alkanes (C 5 -C 10 ), cycloalkanes (C 5 -C 8 ), alkenes (C 5 -C 8 ), alkynes (C 5 -C 8 ), aromatic hydrocarbons (benzene, toluene, ethylbenzene, o-, m-, p-xylene, thiophene), alcohols (C 1 -C 5 ), water, ethers (tetrahydrofuran (THF), methyl-tert-butylether (MTBE), diethyl-, di-n-propyl-, di-n-butyl ether), and ketones (acetone, 2-pentanone, 3-pentanone, 2-hexanone, 3-hexanone, cyclopentanone) at the temperatures from (308.15 to 348.15) K using the inverse gas chromatography (IGC). The density and thermophysical properties of polymer were described. The specific retention volume (V g ), the mass-fraction activity coefficient at infinite dilution (Ω 13 ∞ ), the Flory-Huggins interaction parameter (χ 13 ∞ ), the molar enthalpy of sorption in the polymer (Δ s H), the partial molar excess enthalpy at infinite dilution (ΔH 1 E,∞ ), the molar enthalpy of vaporization to the ideal-gas state for the pure solutes (Δ vap H 0 ), the partial molar Gibbs excess energy at infinite dilution (ΔG 1 E,∞ ), and the solubility parameter of the polymer (δ 3 ), were calculated. The UNIFAC-FV model was used to predict the mass-fraction activity coefficient at infinite dilution for different solutes in the B-H2004 polymer.

  4. Age-dependent doses to members of the public from intake of radionuclides: Pt. 5. Compilation of ingestion and inhalation dose coefficients

    1996-01-01

    The present report is a compilation of age-dependent committed effective dose coefficients for ingestion and inhalation of radionuclides of the 31 elements covered in previous CRP Publications. The biokinetic models for adults given in ICRP Publication 30 are applied to calculate these dose coefficients, except that age-specific excretion rates are used and increased gastrointestinal absorption in infants is assurred. Changes in body mass, and tissue geometry in children are also taken into account. (UK)

  5. Study of non-validity of mixture rule near K-absorption edges by X-ray spectrometric technique

    Sharanabasappa; Chitralekha, A.; Kerur, B.R.; Anilkumar, S.

    2012-01-01

    X-ray spectrometric technique has been described to determine the X-ray mass attenuation coefficient, μ/ρ, of X-rays employing HPGe X-ray detector and radioactive sources. The photon intensity is measured by gating the channel of the spectrometer at FWHM/photo peak. Using the technique the 'best value' values of μ/ρ were obtained for those thicknesses which lie in the transmission (T) range 0.5 ≥ T ≥ 0.02. Total attenuation cross sections for other elements and lead compounds were measured at photon energies from 17 to 88 keV to study the Bragg's additivity law near the absorption edge of the lead. The measured values of mass attenuation coefficient values are compared with theoretical values obtained using Winxcom (programme). This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 17-23%. (author)

  6. Calcium absorption

    Carlmark, B.; Reizenstein, P.; Dudley, R.A.

    1976-01-01

    The methods most commonly used to measure the absorption and retention of orally administered calcium are reviewed. Nearly all make use of calcium radioisotopes. The magnitude of calcium absorption and retention depends upon the chemical form and amount of calcium administered, and the clinical and nutritional status of the subject; these influences are briefly surveyed. (author)

  7. Conversion coefficients for individual monitoring calculated with integrated tiger series, ITS3, Monte Carlo code

    Devine, R.T.; Hsu, Hsiao-Hua

    1994-01-01

    The current basis for conversion coefficients for calibrating individual photon dosimeters in terms of dose equivalents is found in the series of papers by Grosswent. In his calculation the collision kerma inside the phantom is determined by calculation of the energy fluence at the point of interest and the use of the mass energy absorption coefficient. This approximates the local absorbed dose. Other Monte Carlo methods can be sued to provide calculations of the conversion coefficients. Rogers has calculated fluence-to-dose equivalent conversion factors with the Electron-Gamma Shower Version 3, EGS3, Monte Carlo program and produced results similar to Grosswent's calculations. This paper will report on calculations using the Integrated TIGER Series Version 3, ITS3, code to calculate the conversion coefficients in ICRU Tissue and in PMMA. A complete description of the input parameters to the program is given and comparison to previous results is included

  8. Theoretical Influence Coefficients For X-Ray Fluorescence Analysis Of Alloys

    Okunade, I.O.

    2004-01-01

    The problem of quantifications in X-ray fluorescence analysis has over the years been narrowed down to matrix effects arising from the presence of other elements in the sample, which may either lead to the reduction or enhancement in the measured intensities of the analytic element. This paper describes a mathematical matrix correction method, which yield certain fundamental coefficients that account for the inter-element effects. The application of these influence coefficients in quantitative analysis however relies on the knowledge of pure element intensities of the analyse element, its mass absorption coefficients (for exciting and fluorescent radiation) of other elements in the sample that are responsible for the matrix effects. The quantification method using these coefficients are thereafter established for binary systems and further extended to multi-component systems such as ternary and quaternary alloys

  9. Absorption studies

    Ganatra, R.D.

    1992-01-01

    Absorption studies were once quite popular but hardly anyone does them these days. It is easier to estimate the blood level of the nutrient directly by radioimmunoassay (RIA). However, the information obtained by estimating the blood levels of the nutrients is not the same that can be obtained from the absorption studies. Absorption studies are primarily done to find out whether some of the essential nutrients are absorbed from the gut or not and if they are absorbed, to determine how much is being absorbed. In the advanced countries, these tests were mostly done to detect pernicious anaemia where vitamin B 12 is not absorbed because of the lack of the intrinsic factor in the stomach. In the tropical countries, ''malabsorption syndrome'' is quire common. In this condition, several nutrients like fat, folic acid and vitamin B 12 are not absorbed. It is possible to study absorption of these nutrients by radioisotopic absorption studies

  10. A contribution of black and brown carbon to the aerosol light absorption

    Kim, Sang-Woo; Cho, Chaeyoon; Jo, Duseong; Park, Rokjin

    2017-04-01

    Black carbon (BC) is functionally defined as the absorbing component of atmospheric total carbonaceous aerosols and is typically dominated by soot-like elemental carbon (EC). Organic carbon (OC) has also been shown to absorb strongly at visible to UV wavelengths and the absorbing organics are referred to as brown carbon (BrC; Alexander et al., 2008). These two aerosols contribute to solar radiative forcing through absorption of solar radiation and heating of the absorbing aerosol layer, but most optical instruments that quantify light absorption are unable to distinguish one type of absorbing aerosol from another (Moosmüller et al. 2009). In this study, we separate total aerosol absorption from these two different light absorbers from co-located simultaneous in-situ measurements, such as Continuous Soot Monitoring System (COSMOS), Continuous Light Absorption Photometer (CLAP) and Sunset EC/OC analyzer, at Gosan climate observatory, Korea. We determine the mass absorption cross-section (MAC) of BC, and then estimate the contribution of BC and BrC on aerosol light absorption, together with a global 3-D chemical transport model (GEOS-Chem) simulation. At 565 nm wavelength, BC MAC is found to be about 5.4±2.8 m2 g-1 from COSMOS and Sunset EC/OC analyzer measurements during January-May 2012. This value is similar to those from Alexander et al. (2008; 4.3 ˜ 4.8 m2 g-1 at 550 nm) and Chung et al. (2012; 5.1 m2 g-1 at 520 nm), but slightly lower than Bond and Bergstrom (2006; 7.5±1.2 m2 g-1 at 550 nm). The COMOS BC mass concentration calculated with 5.4 m2 g-1 of BC MAC shows a good agreement with thermal EC concentration, with a good slope (1.1). Aerosol absorption coefficient and BC mass concentration from COSMOS, meanwhile, are approximately 25 ˜ 30 % lower than those of CLAP. This difference can be attributable to the contribution of volatile light-absorbing aerosols (i.e., BrC). The absorption coefficient of BrC, which is determined by the difference of

  11. Folate absorption

    Baker, S.J.

    1976-01-01

    Folate is the generic term given to numerous compounds of pteroic acid with glutamic acid. Knowledge of absorption is limited because of the complexities introduced by the variety of compounds and because of the inadequacy of investigational methods. Two assay methods are in use, namely microbiological and radioactive. Techniques used to study absorption include measurement of urinary excretion, serum concentration, faecal excretion, intestinal perfusion, and haematological response. It is probably necessary to test absorption of both pteroylmonoglutamic acid and one or more polyglutamates, and such tests would be facilitated by availability of synthesized compounds labelled with radioactive tracers at specifically selected sites. (author)

  12. Subgap absorption in conjugated polymers

    Sinclair, M.; Seager, C.H. (Sandia National Labs., Albuquerque, NM (USA)); McBranch, D.; Heeger, A.J. (California Univ., Santa Barbara, CA (USA)); Baker, G.L. (Bell Communications Research, Inc., Red Bank, NJ (USA))

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of < 10{sup {minus}5}, Photothermal Deflection Spectroscopy (PDS) is ideal for determining the absorption coefficients of thin films of transparent'' materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination. 11 refs., 4 figs.

  13. Gamma ray attenuation coefficient measurement for neutron-absorbent materials

    Jalali, Majid [Isfahan Nuclear Science and Technology Research Institute (NSTRT), Reactor and Accelerators Research and Development School, Atomic Energy Organization (Iran, Islamic Republic of)], E-mail: m_jalali@entc.org.ir; Mohammadi, Ali [Faculty of Science, Department of Physics, University of Kashan, Km. 6, Ravand Road, Kashan (Iran, Islamic Republic of)

    2008-05-15

    The compounds Na{sub 2}B{sub 4}O{sub 7}, H{sub 3}BO{sub 3}, CdCl{sub 2} and NaCl and their solutions attenuate gamma rays in addition to neutron absorption. These compounds are widely used in the shielding of neutron sources, reactor control and neutron converters. Mass attenuation coefficients of gamma related to the four compounds aforementioned, in energies 662, 778.9, 867.38, 964.1, 1085.9, 1173, 1212.9, 1299.1,1332 and 1408 keV, have been determined by the {gamma} rays transmission method in a good geometry setup; also, these coefficients were calculated by MCNP code. A comparison between experiments, simulations and Xcom code has shown that the study has potential application for determining the attenuation coefficient of various compound materials. Experiment and computation show that H{sub 3}BO{sub 3} with the lowest average Z has the highest gamma ray attenuation coefficient among the aforementioned compounds.

  14. Determination of polydimethylsiloxane–water partition coefficients for ten 1-chloro-4-[2,2,2-trichloro-1-(4-chlorophenyl)ethyl]benzene-related compounds and twelve polychlorinated biphenyls using gas chromatography/mass spectrometry

    Eganhouse, Robert P.

    2016-01-01

    Polymer-water partition coefficients (Kpw) of ten DDT-related compounds were determined in pure water at 25 °C using commercial polydimethylsiloxane-coated optical fiber. Analyte concentrations were measured by thermal desorption-gas chromatography/full scan mass spectrometry (TD–GC/MSFS; fibers) and liquid injection-gas chromatography/selected ion monitoring mass spectrometry (LI–GC/MSSIM; water). Equilibrium was approached from two directions (fiber uptake and depletion) as a means of assessing data concordance. Measured compound-specific log Kpw values ranged from 4.8 to 6.1 with an average difference in log Kpw between the two approaches of 0.05 log units (∼12% of Kpw). Comparison of the experimentally-determined log Kpw values with previously published data confirmed the consistency of the results and the reliability of the method. A second experiment was conducted with the same ten DDT-related compounds and twelve selected PCB (polychlorinated biphenyl) congeners under conditions characteristic of a coastal marine field site (viz., seawater, 11 °C) that is currently under investigation for DDT and PCB contamination. Equilibration at lower temperature and higher ionic strength resulted in an increase in log Kpw for the DDT-related compounds of 0.28–0.49 log units (61–101% of Kpw), depending on the analyte. The increase in Kpw would have the effect of reducing by approximately half the calculated freely dissolved pore-water concentrations (Cfree). This demonstrates the importance of determining partition coefficients under conditions as they exist in the field.

  15. Quenching of Einstein-coefficients by photons

    Aumayr, F.; Skinner, C.H.; Suckewer, S.; Princeton Univ., NJ; Lee, W.

    1991-02-01

    Experimental evidence is presented for the change of Einstein's A-coefficients for spontaneous transitions from the upper laser level of an argon ion laser discharge due to the presence of the high-intensity laser flux. To demonstrate that this quenching effect cannot be attributed to a reduction in self-absorption of the strong spontaneous emission line, absorption and line profile measurements have been performed. Computer modelling of the reduction of self absorption due to Rabi splitting also indicated that this effect is too small to explain the observed quenching of spontaneous line emissions. 13 refs., 11 figs

  16. Quenching of Einstein-coefficients by photons

    Aumayr, F.; Lee, W.; Skinner, C.H.; Suckewer, S.

    1991-03-01

    Experimental evidence is presented for the change of Einstein's A- coefficients for spontaneous transitions from the upper laser level of argon ion laser discharge due to the presence of the high- intensity laser flux. To demonstrate that this quenching effect cannot be attributed to a reduction in self-absorption of the strong spontaneous emission line, absorption and line profile measurements have been performed. Computer modelling of the reduction of self absorption due to Rabi splitting also indicated that this effect is too small to explain the observed quenching of spontaneous line emissions. 13 refs., 11 figs

  17. Nonlinear Absorptions of CdSeTe Quantum Dots under Ultrafast Laser Radiation

    Zhijun Chai

    2016-01-01

    Full Text Available The oil-soluble alloyed CdSeTe quantum dots (QDs are prepared by the electrostatic method. The basic properties of synthesized CdSeTe QDs are characterized by UV-Vis absorption spectroscopy, photoluminescence spectroscopy, inductively coupled plasma mass spectrometry, and transmission electron microscope. The off-resonant nonlinear optical properties of CdSeTe QDs are studied by femtosecond Z-scan at 1 kHz (low-repetition rate and 84 MHz (high-repetition rate. Nonlinear absorption coefficients are calculated under different femtosecond laser excitations. Due to the long luminescent lifetime of CdSeTe QDs, under the conditions of high-repetition rate, for open-aperture curve, heat accumulation and bleaching of ground state are responsible for the decrease of two-photon absorption (TPA coefficient.

  18. Absorption factor for cylindrical samples

    Sears, V.F.

    1984-01-01

    The absorption factor for the scattering of X-rays or neutrons in cylindrical samples is calculated by numerical integration for the case in which the absorption coefficients of the incident and scattered beams are not equal. An extensive table of values having an absolute accuracy of 10 -4 is given in a companion report [Sears (1983). Atomic Energy of Canada Limited, Report No. AECL-8176]. In the present paper an asymptotic expression is derived for the absorption factor which can be used with an error of less than 10 -3 for most cases of interest in both neutron inelastic scattering and neutron diffraction in crystals. (Auth.)

  19. Simulation of solar-powered absorption cooling system

    Atmaca, I.; Yigit, A. [Uludag Univ., Bursa (Turkey). Dept. of Mechanical Engineering

    2003-07-01

    With developing technology and the rapid increase in world population, the demand for energy is ever increasing. Conventional energy will not be enough to meet the continuously increasing need for energy in the future. In this case, renewable energy sources will become important. Solar energy is a very important energy source because of its advantages. Instead of a compressor system, which uses electricity, an absorption cooling system, using renewable energy and kinds of waste heat energy, may be used for cooling. In this study, a solar-powered, single stage, absorption cooling system, using a water-lithium bromide solution, is simulated. A modular computer program has been developed for the absorption system to simulate various cycle configurations and solar energy parameters for Antalya, Turkey. So, the effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling components are studied. In addition, reference temperatures which are the minimum allowable hot water inlet temperatures are determined and their effect on the fraction of the total load met by non-purchased energy (FNP) and the coefficient of performance are researched. Also, the effects of the collector type and storage tank mass are investigated in detail. (author)

  20. Chromatographic determination of the rate and extent of absorption of air pollutants by sea water

    Nikolakaki, S.; Vassilakos, C.; Katsanos, N.A.

    1994-01-01

    A simple chromatographic method is developed to determine the rate constant for expulsion of an air pollutant from water or its diffusion parameter in the liquid, the rate constant for chemical reaction of the pollutant with water, its mass transfer coefficient in the liquid, and the partition coefficient between liquid water and air. From these physicochemical parameters, the absorption rate by sea water and, therefore, the depletion rate of a polluting substance from the air can be calculated, together with the equilibrium state of this absorption. The method has been applied to nitrogen dioxide being absorbed by triple-distilled water and by sea water, at various temperatures. From the temperature variation of the reaction rate constant and of the partition coefficient, the activation energy for the reaction and the differential heat of solution were determined. (orig.)

  1. Gas mass transfer for stratified flows

    Duffey, R.B.; Hughes, E.D.

    1995-01-01

    We analyzed gas absorption and release in water bodies using existing surface renewal theory. We show a new relation between turbulent momentum and mass transfer from gas to water, including the effects of waves and wave roughness, by evaluating the equilibrium integral turbulent dissipation due to energy transfer to the water from the wind. Using Kolmogoroff turbulence arguments the gas transfer velocity, or mass transfer coefficient, is then naturally and straightforwardly obtained as a non-linear function of the wind speed drag coefficient and the square root of the molecular diffusion coefficient. In dimensionless form, the theory predicts the turbulent Sherwood number to be Sh t = (2/√π)Sc 1/2 , where Sh t is based on an integral dissipation length scale in the air. The theory confirms the observed nonlinear variation of the mass transfer coefficient as a function of the wind speed; gives the correct transition with turbulence-centered models for smooth surfaces at low speeds; and predicts experimental data from both laboratory and environmental measurements within the data scatter. The differences between the available laboratory and field data measurements are due to the large differences in the drag coefficient between wind tunnels and oceans. The results also imply that the effect of direct aeration due to bubble entrainment at wave breaking is no more than a 20% increase in the mass transfer for the highest speeds. The theory has importance to mass transfer in both the geo-physical and chemical engineering literature

  2. Experimental assessment of ammonia adiabatic absorption into ammonia-lithium nitrate solution using a flat fan nozzle

    Zacarias, A.; Venegas, M.; Ventas, R.; Lecuona, A.

    2011-01-01

    This paper presents the experimental evaluation of the adiabatic absorption of ammonia vapour into ammonia-lithium nitrate solution using a flat fan nozzle and an upstream single-pass subcooler. Data are representative of the working conditions of adiabatic absorbers in absorption chillers. The nozzle was located at the top of the absorption chamber, separated 205 mm from the bottom surface. The diluted solution mass flow rate was modified between 0.04 and 0.08 kg/s and the solution inlet temperature between 24.5 and 29.7 o C. The influence of these variables on the absorption ratio, mass transfer coefficient, outlet subcooling and approach to equilibrium factor is analysed in the present paper. A linear relation between the inlet subcooling and the absorption ratio is observed. The approach to equilibrium factor for the conditions essayed is always between 0.81 and 0.89. Mass transfer coefficients and correlations for the approach to equilibrium factor and the Sherwood number are obtained. Results are compared with other ones reported in the literature. - Highlights: → Adiabatic absorption of NH 3 vapour into NH 3 -LiNO 3 using flat fan nozzle created spray. → A linear relation exists between solution inlet subcooling and absorption ratio. → The approach to equilibrium factor is always between 0.81 and 0.89 at 205 mm height. → Experimental values of mass transfer coefficient and outlet subcooling are presented. → Correlations for the approach to equilibrium factor and the Sherwood number are given.

  3. Narrative absorption

    Narrative Absorption brings together research from the social sciences and Humanities to solve a number of mysteries: Most of us will have had those moments, of being totally absorbed in a book, a movie, or computer game. Typically we do not have any idea about how we ended up in such a state. No...

  4. Something new: a new approach to correcting theoretical emitted intensities for absorption effects

    Willis, J.P.; Lachance, G.R.

    2002-01-01

    Full text: For monochromatic incident radiation of wavelength λ, absorption only (no enhancement), and ignoring such effects as the absorption edge jump ratio, the fluorescence yield, and the probability that a Kα line will be emitted instead of a Kβ line, a simplified view of the theoretical emitted intensity of a characteristic line of element >i= from a layer in a specimen is given by a familiar equation which involves mass absorption coefficients. While this equation allows for the calculation of the theoretical emitted intensity, it is cumbersome to use when trying to explain X-ray excitation in a step-wise manner. It is therefore proposed that the mass attenuation coefficients (μ iλ , and the sum of μ sλ ' + μ sλi '' , in the numerator and denominator of this equation be replaced by the product of two coefficients correcting for absorption, namely aN H aO. The advantages of using the proposed equation in the stepwise calculation of theoretical intensities (in a similar manner to Monte Carlo calculations) will be discussed. Copyright (2002) Australian X-ray Analytical Association Inc

  5. Absorption corrections for x-ray fluorescence analysis of environmental samples

    Bazan, F.; Bonner, N.A.

    1975-01-01

    The discovery of a very simple and useful relationship between the absorption coefficient of a particular element and the ratio of incoherent to coherent scattering by the sample containing the element is discussed. By measuring the absorption coefficients for a few elements in a few samples, absorption coefficients for many elements in an entire set of similar samples can be obtained. (auth)

  6. Absorption corrections for x-ray fluorescence analysis of environmental samples

    Bazan, F.; Bonner, N.A.

    1976-01-01

    The discovery of a very simple and useful relationship between the absorption coefficient of a particular element and the ratio of incoherent to coherent scattering by the sample containing the element is discussed. By measuring the absorption coefficients for a few elements in a few samples, absorption coefficients for many elements in an entire set of similar samples can be obtained

  7. The use of a reference absorber for absorption measurements in a reverberation chamber

    Nolan, Melanie; Vercammen, Martijn; Jeong, Cheol-Ho

    2014-01-01

    The statistical incidence absorption coefficient is measured in a reverberation room according to ISO 354. This absorption coefficient is referred to as Sabine absorption coefficient, which assumes the chambe r to be completely diffuse. It is known that the reproducibility of these results is poo...

  8. UV absorption reveals mycosporine-like amino acids (MAAs in Tatra mountain lake phytoplankton

    Jerzy Dera

    2013-08-01

    Full Text Available Enhanced absorption of UV radiation, an effect characteristic of mycosporine-like amino acids (MAAs, is reported in samples of phytoplankton from six lakes in the Tatra Mountains National Park (Poland. It was demonstrated that the mass-specific UV absorption coefficients for the phytoplankton in these lakes increased with altitude above sea level. Based on a comparison with the phytoplankton of Alpine lakes, investigated earlier by other authors (cited in this paper, it may be inferred that the phytoplankton of Tatra mountain lakes produce MAAs, which protect plant cells from UV light, the intensity of which increases with altitude.

  9. Compact heat and mass exchangers of the plate fin type in thermal sorption systems: Application in an absorption heat pump with the working pair CH3OH-LiBr/ZnBr2

    Becker, Harry

    The possible application of Compact Heat and Mass Exchangers (CHME) in a gas fired Absorption Heat Pump (AHP) for domestic heating is studied. The above mentioned heat and mass exchangers are of the plate type. The space between the parallel and plain plates is filled up with corrugated plates of a certain height. The plain and finned plates are stacked and welded together. This gives a heat and mass exchanger which is very compact, expressed by a high area density (m2/m3). This leads to heat and mass transfer processes with small temperature and concentration differences. For testing purposes a pilot plant was built using the above type of components in order to test their heat and/or mass transfer performance. Only the generator is of the Shell And Tube (SAT) type. As the working pair, CH3OH - LiBr/ ZnBr2 was chosen, with the alcohol as the solvent and the salt mixture as the absorbent. This leads to sub atmospheric working pressures with only solvent in the vapor phase. Three series of experiments have been carried out, during which the input parameters were varied over a certain range. It is concluded that the plate fin CHMES are very suitable for application in an AHP for domestic heating purposes.

  10. Photoelectric absorption cross sections with variable abundances

    Balucinska-Church, Monika; Mccammon, Dan

    1992-01-01

    Polynomial fit coefficients have been obtained for the energy dependences of the photoelectric absorption cross sections of 17 astrophysically important elements. These results allow the calculation of X-ray absorption in the energy range 0.03-10 keV in material with noncosmic abundances.

  11. Absorptive products

    Assarsson, P.G.; King, P.A.

    1976-01-01

    Applications for hydrophile gels produced by the radiation induced cross-linking in aqueous solution of polyethylene oxide and starch, as described in Norwegian patent 133501 (INIS RN 281494), such as sanitary napkins (diapers) and sanitary towels, are discussed. The process itself is also discussed and results, expressed as the percentage of insoluble gel and its absorptive capacity for saline solution as functions of the ratio of polyethylene oxide to starch and the radiation dose, are presented. (JIW)

  12. Global Multi-isotopologue fit of measured rotation and vibration-rotation line positions of CO in X1Σ+ state and new set of mass-independent Dunham coefficients

    Velichko, T.I.; Mikhailenko, S.N.; Tashkun, S.A.

    2012-01-01

    A set of mass-independent U mj and Δ mj parameters globally describing vibration-rotation energy levels of the CO molecule in the X 1 Σ + ground electronic state was fitted to more than 19,000 transitions of 12 C 16 O, 13 C 16 O, 14 C 16 O, 12 C 17 O, 13 C 17 O, 12 C 18 O, and 13 C 18 O isotopologues collected from the literature. The maximal values of the vibrational V and the rotational J quantum numbers included in the fit was 41 and 128, respectively. The weighted standard deviation of the fit is .66. Fitted parameters were used for calculation of Dunham coefficients Y mj for nine isotopologues 12 C 16 O, 13 C 16 O, 14 C 16 O, 12 C 17 O, 13 C 17 O, 14 C 17 O, 12 C 18 O, 13 C 18 O, and 14 C 18 O. Calculated transition frequencies based on the fitted parameters were compared with previously reported. A critical analysis of the CO HITRAN and HITEMP data is also presented.

  13. Lifshitz tails for the interband light absorption coefficient

    of self-adjoint operators on H is called measurable if the family ..... This is a direct verification to see that the diagonal lines λ1 + λ2 = const passing ..... [2] Carmona R and Lacroix J, Spectral Theory of Random Schrödinger Operators (Boston:.

  14. Determination of sedimentation rates and absorption coefficient of ...

    2+ has a higher sedimentation rate of 5.10x10-2 s-1 while Ni2+ has the lowest sedimentation rates of 1.10 x10-3. The rate of sedimentation of the metal carbonates decreased in the order: Zn2+ > Cd2+ > Cu2+ > Co2+ > Ni2+. The order ...

  15. The Stellar Initial Mass Function in Early-type Galaxies from Absorption Line Spectroscopy. IV. A Super-Salpeter IMF in the Center of NGC 1407 from Non-parametric Models

    Conroy, Charlie [Department of Astronomy, Harvard University, Cambridge, MA, 02138 (United States); Van Dokkum, Pieter G. [Department of Astronomy, Yale University, New Haven, CT, 06511 (United States); Villaume, Alexa [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States)

    2017-03-10

    It is now well-established that the stellar initial mass function (IMF) can be determined from the absorption line spectra of old stellar systems, and this has been used to measure the IMF and its variation across the early-type galaxy population. Previous work focused on measuring the slope of the IMF over one or more stellar mass intervals, implicitly assuming that this is a good description of the IMF and that the IMF has a universal low-mass cutoff. In this work we consider more flexible IMFs, including two-component power laws with a variable low-mass cutoff and a general non-parametric model. We demonstrate with mock spectra that the detailed shape of the IMF can be accurately recovered as long as the data quality is high (S/N ≳ 300 Å{sup −1}) and cover a wide wavelength range (0.4–1.0 μ m). We apply these flexible IMF models to a high S/N spectrum of the center of the massive elliptical galaxy NGC 1407. Fitting the spectrum with non-parametric IMFs, we find that the IMF in the center shows a continuous rise extending toward the hydrogen-burning limit, with a behavior that is well-approximated by a power law with an index of −2.7. These results provide strong evidence for the existence of extreme (super-Salpeter) IMFs in the cores of massive galaxies.

  16. Subgap Absorption in Conjugated Polymers

    Sinclair, M.; Seager, C. H.; McBranch, D.; Heeger, A. J; Baker, G. L.

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination.

  17. Combining Experiments and Simulation of Gas Absorption for Teaching Mass Transfer Fundamentals: Removing CO2 from Air Using Water and NaOH

    Clark, William M.; Jackson, Yaminah Z.; Morin, Michael T.; Ferraro, Giacomo P.

    2011-01-01

    Laboratory experiments and computer models for studying the mass transfer process of removing CO2 from air using water or dilute NaOH solution as absorbent are presented. Models tie experiment to theory and give a visual representation of concentration profiles and also illustrate the two-film theory and the relative importance of various…

  18. Comparative oxidation state specific analysis of arsenic species by high-performance liquid chromatography-inductively coupled-mass spectrometry and hydride generation-cryotrapping-atomic absorption spectrometry

    The formation of methylarsonous acid (MAsIII) and dimethylarsinous acid (DMAsIII) in the course of inorganic arsenic (iAs) metabolism plays an important role in the adverse effects of chronic exposure to iAs. High-performance liquid chromatography-inductively coupled plasma-mass ...

  19. Mass attenuation coefficient (μ/ρ), effective atomic number (Z{sub eff}) and measurement of x-ray energy spectra using based calcium phosphate biomaterials: a comparative study

    Fernandes Z, M. A.; Da Silva, T. A.; Nogueira, M. S. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, Belo Horizonte 31270-901, Minas Gerais (Brazil); Goncalves Z, E., E-mail: madelon@cdtn.br [Pontifice Catholic University of Minas Gerais, Av. Dom Jose Gaspar 500, Belo Horizonte 30535-901, Minas Gerais (Brazil)

    2015-10-15

    In dentistry, alveolar bone regeneration procedures using based calcium phosphate biomaterials have been shown effective. However,there are not reports in the literature of studies the interaction of low energy radiation in these biomaterials used as attenuator and not being then allowed a comparison between the theoretical values and experimental.The objective of this study was to determine the interaction of radiation parameters of four dental biomaterials - BioOss, Cerasorb M Dental, Straumann Boneceramic and Osteogen for diagnostic radiology qualities. As a material and methods, the composition of the biomaterials was determined by the analytical techniques. The samples with 0.181 cm to 0,297 cm thickness were experimentally used as attenuators for the measurement of the transmitted X-rays spectra in X-ray equipment with 50 to 90 kV range by spectrometric system comprising the Cd Te detector. After this procedure, the mass attenuation coefficient, the effective atomic number were determined and compared between all the specimens analyzed, using the program WinXCOM in the range of 10 to 200 keV. In all strains examined observed that the energy spectrum of x-rays transmitted through the BioOss has the mean energy slightly smaller than the others biomaterials for close thickness. The μ/ρ and Z{sub eff} of the biomaterials showed its dependence on photon energy and atomic number of the elements of the material analyzed. It is concluded according to the methodology employed in this study that the measurements of x-ray spectrum, μ/ρ and Z{sub eff} using biomaterials as attenuators confirmed that the thickness, density, composition of the samples, the incident photon energy are factors that determine the characteristics of radiation in a tissue or equivalent material. (Author)

  20. Optical coefficients in a semiconductor quantum ring: Electric field and donor impurity effects

    Duque, C. M.; Acosta, Ruben E.; Morales, A. L.; Mora-Ramos, M. E.; Restrepo, R. L.; Ojeda, J. H.; Kasapoglu, E.; Duque, C. A.

    2016-10-01

    The electron states in a two-dimensional quantum dot ring are calculated in the presence of a donor impurity atom under the effective mass and parabolic band approximations. The effect of an externally applied electric field is also taken into account. The wavefunctions are obtained via the exact diagonalization of the problem Hamiltonian using a 2D expansion within the adiabatic approximation. The impurity-related optical response is analyzed via the optical absorption, relative refractive index change and the second harmonics generation. The dependencies of the electron states and these optical coefficients with the changes in the configuration of the quantum ring system are discussed in detail.