WorldWideScience

Sample records for manual p-17 neutron

  1. NNS computing facility manual P-17 Neutron and Nuclear Science

    International Nuclear Information System (INIS)

    Hoeberling, M.; Nelson, R.O.

    1993-11-01

    This document describes basic policies and provides information and examples on using the computing resources provided by P-17, the Neutron and Nuclear Science (NNS) group. Information on user accounts, getting help, network access, electronic mail, disk drives, tape drives, printers, batch processing software, XSYS hints, PC networking hints, and Mac networking hints is given

  2. Manually controlled neutron-activation system

    International Nuclear Information System (INIS)

    Johns, R.A.; Carothers, G.A.

    1982-01-01

    A manually controlled neutron activation system, the Manual Reactor Activation System, was designed and built and has been operating at one of the Savannah River Plant's production reactors. With this system, samples can be irradiated for up to 24 hours and pneumatically transferred to a shielded repository for decay until their activity is low enough for them to be handled at a radiobench. The Manual Reactor Activation System was built to provide neutron activation of solid waste forms for the Alternative Waste Forms Leach Testing Program. Neutron activation of the bulk sample prior to leaching permits sensitive multielement radiometric analyses of the leachates

  3. FB-line neutron multiplicity counter operation manual

    International Nuclear Information System (INIS)

    Langner, D.G.; Sweet, M.R.; Salazar, S.D.; Kroncke, K.E.

    1998-01-01

    This manual describes the design features, performance, and operating characteristics for the FB-Line Neutron Multiplicity Counter (FBLNMC). The FBLNMC counts neutron multiplicities to quantitatively assay plutonium in many forms, including impure scrap and waste. Monte Carlo neutronic calculations were used to design the high-efficiency (57%) detector that has 113 3 H tubes in a high-density polyethylene body. The new derandomizer circuit is included in the design to reduce deadtime. The FBLNMC can be applied to plutonium masses in the range from a few tens of grams to 5 kg; both conventional coincidence counting and multiplicity counting can be used as appropriate. This manual gives the performance data and preliminary calibration parameters for the FBLNMC

  4. Manual for troubleshooting and upgrading of neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    This manual is intended to assist operators in troubleshooting and upgrading of neutron generators. It is directed particularly to operators and technicians in less experienced laboratories and therefore the descriptions of the principles and techniques of these machines are operator oriented. In addition to a discussion of the main characteristics of neutron generators, detailed information is given on the function of particular commercial units, on common problems related to specific components of accelerators, and on methods of troubleshooting and repair. Detailed schematic and circuit diagrams are provided to help operators in the development and improvement of the generators. The problems treated in the Manual have been collected during several IAEA missions in developing countries. 125 refs, 161 figs, 22 tabs.

  5. Manual for troubleshooting and upgrading of neutron generators

    International Nuclear Information System (INIS)

    1996-11-01

    This manual is intended to assist operators in troubleshooting and upgrading of neutron generators. It is directed particularly to operators and technicians in less experienced laboratories and therefore the descriptions of the principles and techniques of these machines are operator oriented. In addition to a discussion of the main characteristics of neutron generators, detailed information is given on the function of particular commercial units, on common problems related to specific components of accelerators, and on methods of troubleshooting and repair. Detailed schematic and circuit diagrams are provided to help operators in the development and improvement of the generators. The problems treated in the Manual have been collected during several IAEA missions in developing countries. 125 refs, 161 figs, 22 tabs

  6. Neutron-proton scattering experiments and phase analyses for the n-p system in the energy range from 17 to 50 MeV

    International Nuclear Information System (INIS)

    Krupp, H.

    1986-01-01

    In the framework of the study of the nucleon-nucleon interaction neutron-proton scattering experiments were performed at the neutron collimator POLKA of the Karlsruhe cyclotron. Neutrons were produced by the source reaction D(d,n)X in the energy range between 17 and 50 MeV. Measured were the differential cross section, the analyzing power, and the spin correlation coefficient of the elastic n-p scattering. By means of the new data the knowledge of the isospin T=0 scattering phases could be improved. It is for the first time possible to determine the scattering phases for T=1 independently from n-p and p-p data with comparable accuracy. (orig./HSI) [de

  7. High-level neutron coincidence counter maintenance manual

    International Nuclear Information System (INIS)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included

  8. High-level neutron coincidence counter maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  9. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  10. Controlatron Neutron Tube Test Suite Software Manual - Operation Manual (V2.2)

    CERN Document Server

    Noel, W P; Hertrich, R J; Martinez, M L; Wallace, D L

    2002-01-01

    The Controlatron Software Suite is a custom built application to perform automated testing of Controlatron neutron tubes. The software package was designed to allowing users to design tests and to run a series of test suites on a tube. The data is output to ASCII files of a pre-defined format for data analysis and viewing with the Controlatron Data Viewer Application. This manual discusses the operation of the Controlatron Test Suite Software and a brief discussion of state machine theory, as state machine is the functional basis of the software.

  11. The neutron transport code DTF-TRACA. User's manual and input data

    International Nuclear Information System (INIS)

    Anhert, C.

    1979-01-01

    A user's manual of the neutron transport code DTF-TRACA, which is a version of the original DTF-IV with some modifications made at JEN. A detailed input data description is given. The new options developped at JEN are included too. (author)

  12. The neutron transport code DTF-Traca users manual and input data

    Energy Technology Data Exchange (ETDEWEB)

    Ahnert, C

    1979-07-01

    This is a users manual of the neutron transport code DTF-TRACA, which is a version of the original DTF-IV with some modifications made at JEN. A detailed input data descriptions is given. The new options developed at JEN are included too. (Author) 18 refs.

  13. The neutron transport code DTF-Traca users manual and input data

    International Nuclear Information System (INIS)

    Ahnert, C.

    1979-01-01

    This is a users manual of the neutron transport code DTF-TRACA, which is a version of the original DTF-IV with some modifications made at JEN. A detailed input data descriptions is given. The new options developed at JEN are included too. (Author) 18 refs

  14. Neutron coincidence counter for MOX fuel pins in storage trays: users' manual

    International Nuclear Information System (INIS)

    Cowder, L.; Menlove, H.

    1982-08-01

    The neutron coincidence counter for measurement of mixed-oxide fuel pins in storage trays is described. The special detector head has been designed so that the detectors, high-voltage junction boxes, and electronics are interchangeable with those of the high-level neutron coincidence counter system. This manual describes the system components and the operation and maintenance of the counter. The counter was developed at Los Alamos National Laboratory for in-plant inspection applications by the International Atomic Energy Agency

  15. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2012-01-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, the neutron polarization analyzer DNS, the neutron spin-echo spectrometer J-NSE, the small-angle neutron diffractometers KWS-1/-2, the very-small-angle neutron diffractometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  16. Neutron scattering. Experiment manuals

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2010-07-01

    The following topics are dealt with: The thermal triple axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, neutron polarization analysis with tht time-of-flight spectrometer DNS, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering with the KWS-1 and KWS-2 diffractometers, the very-small-angle neutron scattering diffractrometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  17. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2010-01-01

    The following topics are dealt with: The thermal triple axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, neutron polarization analysis with tht time-of-flight spectrometer DNS, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering with the KWS-1 and KWS-2 diffractometers, the very-small-angle neutron scattering diffractrometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  18. FURNACE; a toroidal geometry neutronic program system method description and users manual

    International Nuclear Information System (INIS)

    Verschuur, K.A.

    1984-12-01

    The FURNACE program system performs neutronic and photonic calculations in 3D toroidal geometry for application to fusion reactors. The geometry description is quite general, allowing any torus cross section and any neutron source density distribution for the plasma, as well as simple parametric representations of circular, elliptic and D-shaped tori and plasmas. The numerical method is based on an approximate transport model that produces results with sufficient accuracy for reactor-design purposes, at acceptable calculational costs. A short description is given of the numerical method, and a user manual for the programs of the system: FURNACE, ANISN-PT, LIBRA, TAPEMA and DRAWER is presented

  19. Manufacturing of thermal neutron sensor using pMOS

    International Nuclear Information System (INIS)

    Lee, Nam Ho; Kim, Seung Ho

    2005-05-01

    A pMOSFET sensor having a Gadolinium converter has been invented successfully as a slow neutron sensor that is sensitive to neutron energy down to 0.025 eV. The Gd layer converts low energy neutrons to ionizing radiation of which the amount is proportional to neutron dose. Ionising radiation from neutron reactions changes the charge state of the gate oxide of the pMOSFET. The Gd-pMOSFETs were tested at a neutron beam port of HANARO research reactor and a 60 CO irradiation facility to investigate slow neutron response and gamma response, respectively. The voltage change was proportional to the accumulated slow neutron dose. The results from Gd coupled MOSFET neutron dosemeters shows an excellent sensitivity (15 - 16mV/cGy) and linearity to thermal neutrons with negligible background contamination. The results demonstrate the outstanding performance of the Gd coupled MOSFET neutron dosemeters clearly. The Gd-pMOSFET can also be used in a mixed radiation field by subtracting the voltage change of a pMOSFET without Gd from that of the Gd-pMOSFET

  20. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2014-01-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot-single-crystal diffractometer HEiDi, the three-axis spectrometer PANDA, the backscattering spectrometer SPHERES, the DNS neutron-polarization analysis, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering at KWS-1 and KWS-2, a very-small-angle neutron scattering diffractometer with focusing mirror, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  1. FY17 Status Report on NEAMS Neutronics Activities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. H. [Argonne National Lab. (ANL), Argonne, IL (United States); Jung, Y. S. [Argonne National Lab. (ANL), Argonne, IL (United States); Smith, M. A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-09-30

    Under the U.S. DOE NEAMS program, the high-fidelity neutronics code system has been developed to support the multiphysics modeling and simulation capability named SHARP. The neutronics code system includes the high-fidelity neutronics code PROTEUS, the cross section library and preprocessing tools, the multigroup cross section generation code MC2-3, the in-house meshing generation tool, the perturbation and sensitivity analysis code PERSENT, and post-processing tools. The main objectives of the NEAMS neutronics activities in FY17 are to continue development of an advanced nodal solver in PROTEUS for use in nuclear reactor design and analysis projects, implement a simplified sub-channel based thermal-hydraulic (T/H) capability into PROTEUS to efficiently compute the thermal feedback, improve the performance of PROTEUS-MOCEX using numerical acceleration and code optimization, improve the cross section generation tools including MC2-3, and continue to perform verification and validation tests for PROTEUS.

  2. Adjoint P1 equations solution for neutron slowing down; Solucao das equacoes P1 adjuntas para moderacao de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Carlos Eduardo Santos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2002-07-01

    In some applications of perturbation theory, it is necessary know the adjoint neutron flux, which is obtained by the solution of adjoint neutron diffusion equation. However, the multigroup constants used for this are weighted in only the direct neutron flux, from the solution of direct P1 equations. In this work, the adjoint P1 equations are derived by the neutron transport equation, the reversion operators rules and analogies between direct and adjoint parameters. The direct and adjoint neutron fluxes resulting from the solution of P{sub 1} equations were used to three different weighting processes, to obtain the macrogroup macroscopic cross sections. It was found out noticeable differences among them. (author)

  3. The bidimensional neutron transport code TWOTRAN-GG. Users manual and input data TWOTRAN-TRACA version

    International Nuclear Information System (INIS)

    Ahnert, C.; Aragones, J. M.

    1981-01-01

    This Is a users manual of the neutron transport code TWOTRAN-TRACA, which is a version of the original TWOTRAN-GG from the Los Alamos Laboratory, with some modifications made at JEN. A detailed input data description is given as well as the new modifications developed at JEN. (Author) 8 refs

  4. Electrochemistry of cytochrome P450 17α-hydroxylase/17,20-lyase (P450c17).

    Science.gov (United States)

    Martin, Lisandra L; Kubeil, Clemens; Simonov, Alexandr N; Kuznetsov, Vladimir L; Corbin, C Jo; Auchus, Richard J; Conley, Alan J; Bond, Alan M; Rodgers, Raymond J

    2017-02-05

    Within the superfamily of cytochrome P450 enzymes (P450s), there is a small class which is functionally employed for steroid biosynthesis. The enzymes in this class appear to have a small active site to accommodate the steroid substrates specifically and snuggly, prior to the redox transformation or hydroxylation to form a product. Cytochrome P450c17 is one of these and is also a multi-functional P450, with two activities, the first 17α-hydroxylation of pregnenolone is followed by a subsequent 17,20-lyase transformation to dehydroepiandrosterone (DHEA) as the dominant pathways to cortisol precursors or androgens in humans, respectively. How P450c17 regulates these two redox reactions is of special interest. There is a paucity of direct electrochemical studies on steroidogenic P450s, and in this mini-review we provide an overview of these studies with P450c17. Historical consideration as to the difficulties in obtaining reliable electrochemistry due to issues of handling proteins on an electrode, together with advances in the electrochemical techniques are addressed. Recent work using Fourier transformed alternating current voltammetry is highlighted as this technique can provide both catalytic information simultaneously with the underlying redox transfer with the P450 haem. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Neutron structure analyses and structural disorders of poly(p-phenylenebenzobisoxazole) and poly(p-phenylenebenzobisthiazole)

    International Nuclear Information System (INIS)

    Takahashi, Yasuhiro

    2001-01-01

    Poly(p-phenylenebenzobisoxazole)(PBO) and poly(p-phenylenebenzobisthiazole)(PBZT) are disordered with respect to the molecular heights. The molecular heights of PBO are disordered by 1/2 along the molecular axis, while the molecular heights of PBZT are disordered by 1/2 on the ac-plane and by every 1/5 on the bc-plane. Neutron structure analyses of both polymers were carried out for the c-projected structure in the temperature range 17 - 295K. The molecular structures of both polymers deviate from the planar structure. The crystal structures are less dependent on the temperature than the flexible polymers, polyethylene and poly(vinyl alcohol). (author)

  6. The bidimensional neutron transport code Twotran-GG. User's manual and input data. Twotran-Traca version

    International Nuclear Information System (INIS)

    Ahnert, C.; Aragones, J.M.

    1981-01-01

    A user's manual of the neutron transport code Twotran-Traca is presented; it is a version of the original Twotran-GG from the Los Alamos Laboratory, with some modifications made at J.E.N., Spain. A detailed input data description is given as well as the new modifications developped at J.E.N. (author) [es

  7. System of adjoint P1 equations for neutron moderation; Sistema de equacoes P1 adjuntas para a moderacao de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Aquilino Senra; Silva, Fernando Carvalho da; Cardoso, Carlos Eduardo Santos [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2000-07-01

    In some applications of perturbation theory, it is necessary know the adjoint neutron flux, which is obtained by the solution of adjoint neutron diffusion equation. However, the multigroup constants used for this are weighted in only the direct neutron flux, from the solution of direct P1 equations. In this work, this procedure is questioned and the adjoint P1 equations are derived by the neutron transport equation, the reversion operators rules and analogies between direct and adjoint parameters. (author)

  8. Application of the Trojan Horse Method to study neutron induced reactions: the 17O(n, α14C reaction

    Directory of Open Access Journals (Sweden)

    Gulino M.

    2014-03-01

    Full Text Available The reaction 17O(n, α14C was studied using virtual neutrons coming from the quasi-free deuteron break-up in the three body reaction 17O+d → α+14C+p. This technique, called virtual neutron method, extends the Trojan Horse method to neutron-induced reactions allowing to study the reaction cross section avoiding the suppression effects coming from the penetrability of the centrifugal barrier. For incident neutron energies from thermal up to a few hundred keV, direct experiments have shown the population of two out of three expected excited states at energies 8213 keV and 8282 keV and the influence of the sub-threshold level at 8038 keV. In the present experiment the 18O excited state at E* = 8.125 MeV, missing in the direct measurement, is observed. The angular distributions of the populated resonances have been measured for the first time. The results unambiguously indicate the ability of the method to overcome the centrifugal barrier suppression effect and to pick out the contribution of the bare nuclear interaction.

  9. Adjoint P1 equations solution for neutron slowing down

    International Nuclear Information System (INIS)

    Cardoso, Carlos Eduardo Santos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da

    2002-01-01

    In some applications of perturbation theory, it is necessary know the adjoint neutron flux, which is obtained by the solution of adjoint neutron diffusion equation. However, the multigroup constants used for this are weighted in only the direct neutron flux, from the solution of direct P1 equations. In this work, the adjoint P1 equations are derived by the neutron transport equation, the reversion operators rules and analogies between direct and adjoint parameters. The direct and adjoint neutron fluxes resulting from the solution of P 1 equations were used to three different weighting processes, to obtain the macrogroup macroscopic cross sections. It was found out noticeable differences among them. (author)

  10. CRISP instrument manual

    International Nuclear Information System (INIS)

    Bucknall, D.G.; Langridge, Sean

    1997-05-01

    This document is a user manual for CRISP, one of the two neutron reflectomers at ISIS. CRISP is highly automated allowing precision reproducible measurements. The manual provides detailed instructions for the setting-up and running of the instrument and advice on data analysis. (UK)

  11. 17 CFR 170.10 - Proficiency examinations (sections 4p and 17(p) of the Act).

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Proficiency examinations (sections 4p and 17(p) of the Act). 170.10 Section 170.10 Commodity and Securities Exchanges COMMODITY... examinations (sections 4p and 17(p) of the Act). A futures association may prescribe different training...

  12. Comparing manually-developed and data-driven rules for P2P learning

    CSIR Research Space (South Africa)

    Loots, L

    2009-11-01

    Full Text Available Phoneme-to-phoneme (P2P) learning provides a mechanism for predicting the pronunciation of a word based on its pronunciation in a different accent, dialect or language. The authors evaluate the effectiveness of manually-developed as well...

  13. Neutron monitoring for radiological protection

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1985-01-01

    Neutron monitoring is a subject of increasing general interest and considerable attention is being paid to the development of improved techniques and methods for neutron monitoring. The Agency, therefore, considered it important to prepare a guide on the subject of neutron monitoring for radiation protection purposes. The present Manual is intended for those persons or authorities in Member States, particularly developing countries, who are responsible for the organization of neutron monitoring programmes and practical neutron monitoring. This Manual consequently, deals with topics such as neutron dosimetry, sources of neutrons and neutron detection as well as field instruments and operational systems used in this context

  14. System of adjoint P1 equations for neutron moderation

    International Nuclear Information System (INIS)

    Martinez, Aquilino Senra; Silva, Fernando Carvalho da; Cardoso, Carlos Eduardo Santos

    2000-01-01

    In some applications of perturbation theory, it is necessary know the adjoint neutron flux, which is obtained by the solution of adjoint neutron diffusion equation. However, the multigroup constants used for this are weighted in only the direct neutron flux, from the solution of direct P1 equations. In this work, this procedure is questioned and the adjoint P1 equations are derived by the neutron transport equation, the reversion operators rules and analogies between direct and adjoint parameters. (author)

  15. Neutron interrogation of actinides with a 17 MeV electron accelerator and first results from photon and neutron interrogation non-simultaneous measurements combination

    Energy Technology Data Exchange (ETDEWEB)

    Sari, A., E-mail: adrien.sari@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Carrel, F.; Lainé, F. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Lyoussi, A. [CEA, DEN, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2013-10-01

    In this article, we demonstrate the feasibility of neutron interrogation using the conversion target of a 17 MeV linear electron accelerator as a neutron generator. Signals from prompt neutrons, delayed neutrons, and delayed gamma-rays, emitted by both uranium and plutonium samples were analyzed. First results from photon and neutron interrogation non-simultaneous measurements combination are also reported in this paper. Feasibility of this technique is shown in the frame of the measurement of uranium enrichment. The latter was carried out by combining detection of prompt neutrons from thermal fission and delayed neutrons from photofission, and by combining delayed gamma-rays from thermal fission and delayed gamma-rays from photofission.

  16. A comparison of the potential therapeutic gain of p(66)/Be neutrons and d(14)/Be neutrons

    International Nuclear Information System (INIS)

    Slabbert, Jacobus P.; Theron, Therina; Zoelzer, Friedo; Streffer, Christian; Boehm, Lothar

    2000-01-01

    Purpose: To determine the relationship between photon sensitivity and neutron sensitivity and between neutron RBE and photon resistance for two neutron modalities (with mean energies of 6 and 29 MeV) using human tumor cell lines spanning a wide range of radiosensitivities, the principal objective being whether or not a neutron advantage can be demonstrated. Methods and Materials: Eleven human tumor cell lines with mean photon inactivation doses of 1.65-4.35 Gy were irradiated with 0-5.0 Gy of p(66)/Be neutrons (mean energy of 29 MeV) at Faure, S.A. and the same plating was irradiated on the same day with 0-10.0 Gy of Cobalt-γ-rays . Twelve human tumor cell lines, many of which were identical with the above selection, and spanning mean photon inactivation doses of 1.75-4.08 Gy, were irradiated with 0-4 Gy of d(14)/Be neutrons (mean energy of 6 MeV) and with 0-10 Gy of 240 kVp X-rays at the Essen Klinikum. Cell survival was determined by the clonogenic assay, and data were fitted to the linear quadratic equation. Results: 1. Using the mean inactivation dose, a significant correlation was found to exist between neutron sensitivity and photon sensitivity. However, this correlation was more pronounced in the Faure beam (r 2 = 0.89 , p ≤ 0.0001) than in the Essen beam (r 2 = 0.65, p = 0.0027). 2. No significant relationship could be established between neutron RBE and photon resistance for both modalities (p = 0.69 and p = 0.07, respectively). 3. Using α-coefficients as a criterion, the neutron sensitivity for the Faure beam correlated with photon sensitivity (p = 0.001), but this did not apply to the Essen beam (p = 0.27). 4. The neutron RBE for the Essen beam derived from α-coefficients showed a steep increase with photon resistance (p = 0.003). In the Faure beam there was no increase of RBE with photon resistance (p = 0.494). Conclusion: Radiobiological differences between high-energy and low-energy neutrons are particularly apparent in the dependence of the

  17. Shell gap reduction in neutron-rich N=17 nuclei

    International Nuclear Information System (INIS)

    Obertelli, A.; Gillibert, A.; Alamanos, N.; Alvarez, M.; Auger, F.; Dayras, R.; Drouart, A.; France, G. de; Jurado, B.; Keeley, N.; Lapoux, V.; Mittig, W.; Mougeot, X.; Nalpas, L.; Pakou, A.; Patronis, N.; Pollacco, E.C.; Rejmund, F.; Rejmund, M.; Roussel-Chomaz, P.; Savajols, H.; Skaza, F.; Theisen, Ch.

    2006-01-01

    The spectroscopy of 27 Ne has been investigated through the one-neutron transfer reaction 26 Ne(d,p) 27 Ne in inverse kinematics at 9.7 MeV/nucleon. The results strongly support the existence of a low-lying negative parity state in 27 Ne, which is a signature of a reduced sd-fp shell gap in the N=16 neutron-rich region, at variance with stable nuclei

  18. Magnetization and neutron diffraction studies of Lu.sub.2./sub.Fe.sub.17./sub. under high pressure

    Czech Academy of Sciences Publication Activity Database

    Kamarád, Jiří; Prokhnenko, Olexandr; Prokeš, K.; Arnold, Zdeněk

    2005-01-01

    Roč. 17, - (2005), S3069-S3075 ISSN 0953-8984 R&D Projects: GA ČR(CZ) GP202/04/P014; GA ČR(CZ) GA202/02/0739 Grant - others:European Commission(XE) RII3-CT-2003-505925 (NMI3) Institutional research plan: CEZ:AV0Z10100521 Keywords : intermetallic compounds * neutron diffraction * pressure effect * helimagnetic structure * magnetic phase transitions Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.145, year: 2005

  19. Isotopic neutron sources for neutron activation analysis

    International Nuclear Information System (INIS)

    Hoste, J.

    1988-06-01

    This User's Manual is an attempt to provide for teaching and training purposes, a series of well thought out demonstrative experiments in neutron activation analysis based on the utilization of an isotopic neutron source. In some cases, these ideas can be applied to solve practical analytical problems. 19 refs, figs and tabs

  20. P-wave assignment of 232Th neutron resonances

    International Nuclear Information System (INIS)

    Corvi, F.; Pasquariello, G.; Veen, T. van der

    1978-01-01

    A method of p-wave assignment which exploits the parity dependence of the primary capture γ-ray spectrum was applied to the 232 Th resonance. The yield of capture γ-rays above 4.4 MeV from a 6 mm thick metallic thorium disk was measured in the neutron energy range 20-2200 eV and compared to a similar run with γ-rays in the range 3.7 - 4.4 MeV. A total of 58 resonances showing an enhancement of the high energy γ-ray yield were assigned as p-waves. Assuming that their reduced neutron widths follow a Porter-Thomas distribution, their average value and then the p-wave strength function S 1 were estimated with a maximum likelihood method. The results are: average neutron width=3.4(+0.8 or -0.6)meV; S 1 = 2.0 (+0.5 or -0.4).10 -4

  1. Measurement of the 64Zn,47Ti(n,p) cross sections using a DD neutron generator for medical isotope studies

    Science.gov (United States)

    Voyles, A. S.; Basunia, M. S.; Batchelder, J. C.; Bauer, J. D.; Becker, T. A.; Bernstein, L. A.; Matthews, E. F.; Renne, P. R.; Rutte, D.; Unzueta, M. A.; van Bibber, K. A.

    2017-11-01

    Cross sections for the 47Ti(n,p)47Sc and 64Zn(n,p)64Cu reactions have been measured for quasi-monoenergetic DD neutrons produced by the UC Berkeley High Flux Neutron Generator (HFNG). The HFNG is a compact neutron generator designed as a "flux-trap" that maximizes the probability that a neutron will interact with a sample loaded into a specific, central location. The study was motivated by interest in the production of 47Sc and 64Cu as emerging medical isotopes. The cross sections were measured in ratio to the 113In(n,n‧)113mIn and 115In(n,n‧)115mIn inelastic scattering reactions on co-irradiated indium samples. Post-irradiation counting using an HPGe and LEPS detectors allowed for cross section determination to within 5% uncertainty. The 64Zn(n,p)64Cu cross section for 2.76-0.02+0.01 MeV neutrons is reported as 49.3 ± 2.6 mb (relative to 113In) or 46.4 ± 1.7 mb (relative to 115In), and the 47Ti(n,p)47Sc cross section is reported as 26.26 ± 0.82 mb. The measured cross sections are found to be in good agreement with existing measured values but with lower uncertainty (neutron sources for nuclear data measurements and potentially the production of radionuclides for medical applications.

  2. The bidimensional neutron transport code TWOTRAN-GG. Users manual and input data TWOTRAN-TRACA version; El codigo de transporte bidimensional TWOTRAN-GG. Manual de usuario y datos de entrada version TWOTRAN-TRACA

    Energy Technology Data Exchange (ETDEWEB)

    Ahnert, C; Aragones, J M

    1981-07-01

    This Is a users manual of the neutron transport code TWOTRAN-TRACA, which is a version of the original TWOTRAN-GG from the Los Alamos Laboratory, with some modifications made at JEN. A detailed input data description is given as well as the new modifications developed at JEN. (Author) 8 refs.

  3. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    Science.gov (United States)

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of

  4. Fast neutron relaxation length in concretes in the range of neutron energies En=0.5 - 17.5 MeV

    International Nuclear Information System (INIS)

    Desdin, L.F.; Garcia, L.; Perez, G.; Hernandez, A.; Herrera, E.; Tellez, E.

    1998-01-01

    In the present research were determined the fast neutron relaxation length y in different type of concretes, having special interest for biological shielding as well as for ordinary construction purposes, in the energy interval of 0.5-17.5 MeV. The values of Y concrete are reported with an accuracy of 6 %

  5. Concentration of 17 Elements in Subcellular Fractions of Beef Heart Tissue Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1964-12-15

    Subcellular fractions of beef heart tissue are investigated, by means of neutron activation analysis, with respect to their concentration of 17 different elements. A recently developed ion-exchange technique combined with gamma spectrometry is used. The homogeneity of the subcellular fractions is examined electron microscopically. The following elements are determined: As, Ba, Br, Cas Co, Cs, Cu, Fe, Hg, La, Mo, P, Rb, Se, Sm, W and Zn. The determination of Ag, Au, Cd, Ce, Cr, Sb and Sc is omitted, in view of contamination. Reproducible and characteristic patterns of distribution are obtained for all elements studied.

  6. Concentration of 17 Elements in Subcellular Fractions of Beef Heart Tissue Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1964-12-01

    Subcellular fractions of beef heart tissue are investigated, by means of neutron activation analysis, with respect to their concentration of 17 different elements. A recently developed ion-exchange technique combined with gamma spectrometry is used. The homogeneity of the subcellular fractions is examined electron microscopically. The following elements are determined: As, Ba, Br, Cas Co, Cs, Cu, Fe, Hg, La, Mo, P, Rb, Se, Sm, W and Zn. The determination of Ag, Au, Cd, Ce, Cr, Sb and Sc is omitted, in view of contamination. Reproducible and characteristic patterns of distribution are obtained for all elements studied

  7. Neutron resonance spectroscopy on 113Cd: The p-wave levels

    International Nuclear Information System (INIS)

    Frankle, C.M.; Bowman, C.D.; Bowman, J.D.; Seestrom, S.J.; Sharapov, E.I.; Popov, Y.P.; Roberson, N.R.

    1992-01-01

    Weak levels in the compound nucleus 114 Cd were located by neutron time-of-flight spectroscopy techniques. Neutron capture measurements were performed with both a natural cadmium target and a highly enriched 113 Cd target. A total of 22 new resonances were located in the neutron energy interval 20-500 eV and were assumed to be p-wave. Resonance parameters, E 0 and gΓ n , are given for the newly identified levels. The p-wave strength function was determined to be 10 4 S 1 =2.8±0.8 and the average level spacing left-angle D 1 right-angle=14 eV. Comparison of the reduced widths with a Porter-Thomas distribution is consistent with having missed 15% of the p-wave levels

  8. Application of neutron transmutation doping method to initially p-type silicon material.

    Science.gov (United States)

    Kim, Myong-Seop; Kang, Ki-Doo; Park, Sang-Jun

    2009-01-01

    The neutron transmutation doping (NTD) method was applied to the initially p-type silicon in order to extend the NTD applications at HANARO. The relationship between the irradiation neutron fluence and the final resistivity of the initially p-type silicon material was investigated. The proportional constant between the neutron fluence and the resistivity was determined to be 2.3473x10(19)nOmegacm(-1). The deviation of the final resistivity from the target for almost all the irradiation results of the initially p-type silicon ingots was at a range from -5% to 2%. In addition, the burn-up effect of the boron impurities, the residual (32)P activity and the effect of the compensation characteristics for the initially p-type silicon were studied. Conclusively, the practical methodology to perform the neutron transmutation doping of the initially p-type silicon ingot was established.

  9. Testing T-odd, p-even interactions with gamma-rays from neutron p-wave resonances

    International Nuclear Information System (INIS)

    Barabanov, A.L.

    1992-01-01

    A new method for the study of time reversal violation is described. It consists of measurements of the forward-backward asymmetry in individual gamma-ray transitions resulting from unpolarized neutron capture in p-wave resonance. An experiment with a 113 Cd target performed at the Dubna pulsed neutron source has been analyzed and a limit on the time reversal odd, parity even interaction extracted. The possibilities of experiments using the powerful pulsed neutron source at Los Alamos are considered. 23 refs.; 2 figs

  10. Formation of Nitrogen-13, Fluorine-17, and Fluorine-18 in Reactor-Irradiated H{sub 2}O and D{sub 2}O and Applications to Activation Analysis and Fas Neutron Flux Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hammar, L; Forsen, S

    1964-12-15

    The equivalent macroscopic U{sup 235} -fission neutron cross-sections with respect to formation of the following nuclei were measured and found to be: N{sup 13} in H{sub 2}O, 13.5 {+-} 2; N{sup 13} in D{sub 2}O, 0.24 {+-} 0.05; F{sup 17} in D{sub 2}O, 3500 {+-} 700; F{sup 18} in H{sub 2}O 5.6 {+-} 0.9; and F{sup 18} in D{sub 2}O 4.1 {+-} 0.6 units of 10{sup -10}/cm. The yield of N{sup 13} in D{sub 2}O refers to D{sub 2}O containing no H, and the yield of F{sup 18} in D{sub 2}O to an O{sup 17}/O{sup 16} ratio of 0.0391 {+-} 0.0007. Good agreement was obtained in comparing the measured yields of N{sup 13} and F{sup 18} in H{sub 2}O with estimates based on calculations of the neutron induced flux of knock-on protons and on published cross-section data for the reactions O{sup 16} (p, {alpha} ) N{sup 13} and O{sup 18} (p, n) F{sup 18}. The similarly calculated yield of F{sup 17} in D{sub 2}O due to the reaction O{sup 16} (d, n) F{sup 17} was 6 times less than the observed yield. This discrepancy could not be eliminated by taking into account the anisotropy of the neutron-scattering by deuterons. The formation of F{sup 18} in D{sub 2}O was attributed to the reaction O{sup 17} (d, n) F{sup 18}. This reaction may be utilized for the determination of the O{sup 17}/O{sup 16} ratio in heavy water by neutron activation analysis, e.g. as a means of differentiating between heavy water qualities, obtained by different techniques of enrichment. The formation of N{sup 13} in D{sub 2}O, that cannot be attributed to the O{sup 16} (p, {alpha}) N{sup 13} reaction due to residual H content, is suggested to be caused by the reaction O{sup 16} (d, n{alpha}) N{sup 13}, not previously reported. The cross-section of this reaction per knock-on deuteron at energies above the estimated reaction threshold (8.4 MeV), corresponding to the yield of N{sup 13} is 8 {+-} 2 mb. Application of the O{sup 16} (p, {alpha}) N{sup 13} reaction for neutron activation analysis of H in D{sub 2}O is possible, in

  11. Statistical analysis of P-wave neutron reduced widths

    International Nuclear Information System (INIS)

    Joshi, G.C.; Agrawal, H.M.

    2000-01-01

    The fluctuations of the p-wave neutron reduced widths for fifty one nuclei have been analyzed with emphasis on recent measurements by a statistical procedure which is based on the method of maximum likelihood. It is shown that the p-wave neutron reduced widths of even-even nuclei fallow single channel Porter Thomas distribution (χ 2 -distribution with degree of freedom ν=1) for most of the cases where there are no intermediate structure. It is emphasized that the distribution in nuclei other than even-even may differ from a χ 2 -distribution with one degree of freedom. Possible explanation and significance of this deviation from ν=1 is given. (author)

  12. PUNCH. GENIE MK.2.2 manual

    International Nuclear Information System (INIS)

    David, W.I.F.; Johnson, M.W.; Knowles, K.J.; Crosbie, G.D.; Graham, S.P.; Campbell, E.P.; Lyall, J.S.

    1986-01-01

    GENIE is a language for spectrum manipulation and display, that has been developed to satisfy the data-analysis requirements for all the neutron-scattering instruments at the spallation neutron source. The manual contains: the GENIE 'keyboard' commands, GENIE 'GCL' commands, command file examples, and the adding of non-standard facilities. (U.K.)

  13. X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

    International Nuclear Information System (INIS)

    Wharton, C. J.; Seabury, E. H.; Chichester, D. L.; Caffrey, A. J.; Simpson, J.; Lemchak, M.

    2011-01-01

    Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

  14. Potential therapeutic gain from using p(66)/Be neutrons

    International Nuclear Information System (INIS)

    Slabbert, J.P.; Jones, D.T.L.; Theron, C.; Serafin, A.; Bohm, L.; Schmitt, G.

    1997-01-01

    Neutron therapy will be beneficial to patients with tumor types which are resistant to photons but relatively sensitive to high-LET radiation. In this work 15 different cell types, mostly of human tumor decent, were exposed in vitro to 60 Co γ-rays and p(66)/Be neutrons. Micronuclei frequencies in bi-nucleated cells and surviving fractions were determined for each cell type. Following exposure to either 1 or 1.5 Gy neutrons, micronuclei frequencies were significantly correlated with that observed from 2 Gy photons. A strong correlation between mean inactivation doses determined for these radiation modalities from survival curve inactivation parameters, was also noted. In spite of this a significant correlation between the variation in neutron RBE values and photon resistance was established. It is concluded that although neutron and photo sensitivities are related in the group of cell types studies, the use of this high energy neutron source may constitute a potential therapeutic gain for some tumor types. (authors)

  15. Amorphous-to-crystalline phase transformation by neutron irradiation of the alloy Fe83B17

    International Nuclear Information System (INIS)

    Weis, J.; Gabris, F.; Cerven, I.; Sitek, J.

    1984-01-01

    The purpose of the present work is to investigate the structural changes of amorphous Fe 83 B 17 alloy after irradiation with fast neutrons ( > 1 MeV) and to compare with the crystallization behaviour of the amorphous Fe 83 B 17 alloy after annealing. The structural changes were studied by Moessbauer spectroscopy and X-ray diffraction with the usual Fourier analysis. (author)

  16. APPLE-3: improvement of APPLE for neutron and gamma-ray flux, spectrum and reaction rate plotting code, and of its code manual

    International Nuclear Information System (INIS)

    Kawasaki, Hiromitu; Maki, Koichi; Seki, Yasushi.

    1991-03-01

    A code APPLE was produced in 1976 for calculating and plotting tritium breeding ratio and tritium production rate distributions. That code was improved as 'APPLE-2' in 1982, to calculate and plot not only tritium breeding ratio but also distributions of neutron and gamma-ray fluxes, their spectra, nuclear heating rates and other reaction rates, and dose rate distributions during operation and after shutdown in 1982. The code APPLE-2 can calculate and plot these nuclear properties derived from neutron and gamma-ray fluxes by ANISN (one dimensional transport code), DOT3.5 (two dimensional transport code) and MORSE (three dimensional Monte Carlo code). We revised the code APPLE-2 as 'APPLE-3' by adding many functions to the APPLE-2 code in accordance with users' requirements proposed in recent progress of fusion reaction nuclear design. With minor modification of APPLE-2, a number of inconsistencies have been found between the code manual and the input data in the code. In the present report, the new functions added to APPLE-2 and improved users' manual are explained. (author)

  17. What Do s- and p-Wave Neutron Average Radiative Widths Reveal

    Energy Technology Data Exchange (ETDEWEB)

    Mughabghab, S.F.

    2010-04-30

    A first observation of two resonance-like structures at mass numbers 92 and 112 in the average capture widths of the p-wave neutron resonances relative to the s-wave component is interpreted in terms of a spin-orbit splitting of the 3p single-particle state into P{sub 3/2} and P{sub 1/2} components at the neutron separation energy. A third structure at about A = 124, which is not correlated with the 3p-wave neutron strength function, is possibly due to the Pygmy Dipole Resonance. Five significant results emerge from this investigation: (i) The strength of the spin-orbit potential of the optical-model is determined as 5.7 {+-} 0.5 MeV, (ii) Non-statistical effects dominate the p-wave neutron-capture in the mass region A = 85 - 130, (iii) The background magnitude of the p-wave average capture-width relative to that of the s-wave is determined as 0.50 {+-} 0.05, which is accounted for quantitatively in tenns of the generalized Fermi liquid model of Mughabghab and Dunford, (iv) The p-wave resonances arc partially decoupled from the giant-dipole resonance (GDR), and (v) Gamma-ray transitions, enhanced over the predictions of the GDR, are observed in the {sup 90}Zr - {sup 98}Mo and Sn-Ba regions.

  18. DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

    OpenAIRE

    Sunardi, Sunardi; Muryono, Muryono

    2010-01-01

    Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec).  At this research condition of neutron generator was set at...

  19. Spectroscopy of 17C via one-neutron knockout reaction

    Directory of Open Access Journals (Sweden)

    Kim Sunji

    2016-01-01

    Full Text Available A spectroscopic study of 17C was performed via the one-neutron knockout reaction of 18C on a carbon target at RIKEN-RIBF. Three unbound states at excitation energies of 2.66(2, 3.16(5, and 3.97(3 MeV (preliminary were observed. The energies are compared with shell-model calculations and existing measurements to deduce their spin-parities. From the comparison, the states at 2.66(2 and 3.97(3 MeV are suggested to be 1/2− and 3/2−, respectively. From its decay property, the state at 3.16(5 MeV is indicated to be 9/2+.

  20. DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

    Directory of Open Access Journals (Sweden)

    Sunardi Sunardi

    2010-06-01

    Full Text Available Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec.  At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and  experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are  2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively.  The data  indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator.   Keywords: limit detection, AANC, neutron generator

  1. Quasifree (p ,p N ) scattering of light neutron-rich nuclei near N =14

    Science.gov (United States)

    Díaz Fernández, P.; Alvarez-Pol, H.; Crespo, R.; Cravo, E.; Atar, L.; Deltuva, A.; Aumann, T.; Avdeichikov, V.; Beceiro-Novo, S.; Bemmerer, D.; Benlliure, J.; Bertulani, C. A.; Boillos, J. M.; Boretzky, K.; Borge, M. J. G.; Caamaño, M.; Cabanelas, P.; Caesar, C.; Casarejos, E.; Catford, W.; Cederkäll, J.; Chartier, M.; Chulkov, L. V.; Cortina-Gil, D.; Datta Pramanik, U.; Dillmann, I.; Elekes, Z.; Enders, J.; Ershova, O.; Estradé, A.; Farinon, F.; Fernández-Domínguez, B.; Fraile, L. M.; Freer, M.; Galaviz, D.; Geissel, H.; Gernhäuser, R.; Golubev, P.; Göbel, K.; Hagdahl, J.; Heftrich, T.; Heil, M.; Heine, M.; Heinz, A.; Henriques, A.; Holl, M.; Hufnagel, A.; Ignatov, A.; Johansson, H. T.; Jonson, B.; Jurčiukonis, D.; Kalantar-Nayestanaki, N.; Kanungo, R.; Kelic-Heil, A.; Knyazev, A.; Kröll, T.; Kurz, N.; Labiche, M.; Langer, C.; Le Bleis, T.; Lemmon, R.; Lindberg, S.; Machado, J.; Marganiec, J.; Moro, A. M.; Movsesyan, A.; Nacher, E.; Najafi, A.; Nikolskii, E.; Nilsson, T.; Nociforo, C.; Panin, V.; Paschalis, S.; Perea, A.; Petri, M.; Pietras, B.; Pietri, S.; Plag, R.; Reifarth, R.; Ribeiro, G.; Rigollet, C.; Rossi, D.; Röder, M.; Savran, D.; Scheit, H.; Simon, H.; Sorlin, O.; Syndikus, I.; Taylor, J. T.; Tengblad, O.; Thies, R.; Togano, Y.; Vandebrouck, M.; Velho, P.; Volkov, V.; Wagner, A.; Wamers, F.; Weick, H.; Wheldon, C.; Wilson, G.; Winfield, J. S.; Woods, P.; Yakorev, D.; Zhukov, M.; Zilges, A.; Zuber, K.; R3B Collaboration

    2018-02-01

    Background: For many years, quasifree scattering reactions in direct kinematics have been extensively used to study the structure of stable nuclei, demonstrating the potential of this approach. The R 3B collaboration has performed a pilot experiment to study quasifree scattering reactions in inverse kinematics for a stable 12C beam. The results from that experiment constitute the first quasifree scattering results in inverse and complete kinematics. This technique has lately been extended to exotic beams to investigate the evolution of shell structure, which has attracted much interest due to changes in shell structure if the number of protons or neutrons is varied. Purpose: In this work we investigate for the first time the quasifree scattering reactions (p ,p n ) and (p ,2 p ) simultaneously for the same projectile in inverse and complete kinematics for radioactive beams with the aim to study the evolution of single-particle properties from N =14 to N =15 . Method: The structure of the projectiles 23O, 22O, and 21N has been studied simultaneously via (p ,p n ) and (p ,2 p ) quasifree knockout reactions in complete inverse kinematics, allowing the investigation of proton and neutron structure at the same time. The experimental data were collected at the R3B -LAND setup at GSI at beam energies of around 400 MeV/u. Two key observables have been studied to shed light on the structure of those nuclei: the inclusive cross sections and the corresponding momentum distributions. Conclusions: The knockout reactions (p ,p n ) and (p ,2 p ) with radioactive beams in inverse kinematics have provided important and complementary information for the study of shell evolution and structure. For the (p ,p n ) channels, indications of a change in the structure of these nuclei moving from N =14 to N =15 have been observed, i.e., from the 0 d5 /2 shell to the 1 s1 /2 . This supports previous observations of a subshell closure at N =14 for neutron-rich oxygen isotopes and its weakening

  2. Angular Distributions of Neutrons from (p,n)-Reactions in some Mirror Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Stroemberg, L G; Wiedling, T; Holmqvist, B

    1964-04-15

    The angular distributions of neutrons from the reactions {sup 13}C (p,n) {sup 13}N and {sup 19}F (p, n) {sup 19}Ne have been measured for some energies close to the reactions threshold. For the reaction {sup 9}B (p, n) {sup 9}C angular distributions have been measured at several proton energies below the reaction threshold of the neutrons to the first excited state in {sup 11}C . A 5.5 MeV Van de Graaff has been used for the experiments. The neutrons were detected with a long counter. The measurements were carried out for 16 energies for the B (p,n) reaction, 3 energies for the C (p, n) reaction, and for 7 energies for the F 19(p, n) reaction. One of the main reasons for investigating these (p, n) reactions was to check whether the direct reaction process is important at low proton energies as well as close to reaction thresholds in nuclei consisting of closed shells of neutrons and protons either with an extra nucleon outside the closed shell or a nucleon hole. Comparisons with a theory proposed by Bloom, Glendenning, and Moszkowski have been performed.

  3. Neutron stars as cosmic neutron matter laboratories

    International Nuclear Information System (INIS)

    Pines, D.

    1986-01-01

    Recent developments which have radically changed our understanding of the dynamics of neutron star superfluids and the free precession of neutron stars are summarized, and the extent to which neutron stars are cosmic neutron matter laboratories is discussed. 17 refs., 1 tab

  4. Mechanistic Scrutiny Identifies a Kinetic Role for Cytochrome b5 Regulation of Human Cytochrome P450c17 (CYP17A1, P450 17A1.

    Directory of Open Access Journals (Sweden)

    Alexandr N Simonov

    Full Text Available Cytochrome P450c17 (P450 17A1, CYP17A1 is a critical enzyme in the synthesis of androgens and is now a target enzyme for the treatment of prostate cancer. Cytochrome P450c17 can exhibit either one or two physiological enzymatic activities differentially regulated by cytochrome b5. How this is achieved remains unknown. Here, comprehensive in silico, in vivo and in vitro analyses were undertaken. Fluorescence Resonance Energy Transfer analysis showed close interactions within living cells between cytochrome P450c17 and cytochrome b5. In silico modeling identified the sites of interaction and confirmed that E48 and E49 residues in cytochrome b5 are essential for activity. Quartz crystal microbalance studies identified specific protein-protein interactions in a lipid membrane. Voltammetric analysis revealed that the wild type cytochrome b5, but not a mutated, E48G/E49G cyt b5, altered the kinetics of electron transfer between the electrode and the P450c17. We conclude that cytochrome b5 can influence the electronic conductivity of cytochrome P450c17 via allosteric, protein-protein interactions.

  5. Los Alamos waste drum shufflers users manual

    International Nuclear Information System (INIS)

    Rinard, P.M.; Adams, E.L.; Painter, J.

    1993-01-01

    This user manual describes the Los Alamos waste drum shufflers. The primary purpose of the instruments is to assay the mass of 235 U (or other fissile materials) in drums of assorted waste. It can perform passive assays for isotopes that spontaneously emit neutrons or active assays using the shuffler technique as described on this manual

  6. Measurement of the energy spectrum from the neutron source p lanned for IGISOL

    CERN Document Server

    Mattera, A; Rakopoulos, V; Lantz, M; Pomp, S; Solders, A; Al-Adili, A; Andersson, P; Hjalmarsson, A; Valldor-Blücher, B; Prokofiev, A; Passoth, E; Gentile, A; Bortot, D; Esposito, A; Introini, M V; Pola, A; Penttilä, H; Gorelov, D; Rinta-Antila, S

    2014-01-01

    We report on the characterisation measurements of the energ y spectra from a Be (p,xn) neutron source to be installed at the IGISOL-JYFLTRA P facility for studies of neutron-induced independent fission yields. The measurements were performed at The Svedberg Laboratory (Uppsala, Sweden), during 50 hours of beam-time in June, 2012. A 30 MeV p roton beam impinged on a mock-up of the proton-neutron converter; this was a 5 mm-thick beryllium disc inserted in an aluminium holder, with a 1-cm t hick layer of cool- ing water on the backside. The geometry of the mock-up has bee n chosen to reproduce the one that will be used as the IGISOL-JYFLTRAP so urce. During the experiment, two configurations for the neutron so urce have been used: a fast neutron field, produced using the bare target; an d a moderated field, obtained adding a 10 cm-thick Polyethylene block after the t arget assembly. The neutron fields have been measured using an Extended Range Bonner Sphere Spectrometer (ERBSS), able to simultaneously determine ...

  7. Determination of the neutron magnetic moment

    International Nuclear Information System (INIS)

    Greene, G.L.; Ramsey, N.F.; Mampe, W.; Pendlebury, J.M.; Smith, K.; Dress, W.B.; Miller, P.D.; Perrin, P.

    1981-01-01

    The neutron magnetic moment has been measured with an improvement of a factor of 100 over the previous best measurement. Using a magnetic resonance spectrometer of the separated oscillatory field type capable of determining a resonance signal for both neutrons and protons (in flowing H 2 O), we find μ/sub n//μ/sub p/ = 0.68497935(17) (0.25 ppM). The neutron magnetic moment can also be expressed without loss of accuracy in a variety of other units

  8. Theory of neutron emission in fission

    International Nuclear Information System (INIS)

    Madland, D.G.

    1989-01-01

    Following a summary of the observables in neutron emission in fission, a brief history is given of theoretical representations of the prompt fission neutron spectrum N(E) and average prompt neutron multiplicity /bar /nu///sub p/. This is followed by descriptions, together with examples, of modern approaches to the calculation of these quantities including recent advancements. Emphasis will be placed upon the predictability and accuracy of the modern approaches. In particular, the dependence of N(E) and /bar /nu///sub p/ on the fissioning nucleus and its excitation energy will be discussed, as will the effects of and competition between first-, second- and third-chance fission in circumstances of high excitation energy. Finally, properties of neutron-rich (fission-fragment) nuclei are discussed that must be better known to calculate N(E) and /bar /nu///sub p/ with higher accuracy than is currently possible. 17 refs., 11 figs

  9. Low energy 7Li(p,n)7Be neutron source (CANUTRON)

    International Nuclear Information System (INIS)

    Lone, M.A.; Ross, A.M.; Fraser, J.S.; Schriber, S.O.; Kushneriuk, S.A.; Selander, W.N.

    1982-04-01

    Characteristics of a neutron source based on the 7 Li(p,n) reaction at 2.5 MeV are investigated. It is shosn that with a 10-50 mA beam current this reaction provides a useful source for neutron radiography and other industrial applications

  10. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Torii, Yoshiya

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  11. A survey of neutron energy spectra and angular distributions of the 9Be(p,n)9B reaction for fast neutron radiotherapy

    International Nuclear Information System (INIS)

    Allab, M.

    1984-03-01

    Encouraging findings in radiobiology have stimulated a renewed use of fast neutrons in radiotherapy. The physical characteristics required for neutron beams to be suitable for radiotherapy are well established. As a result, the tendency is to replace the previous machines which generated the neutron beams from deuteron bombardment of thick targets (T, Li, Be) by hospital based cyclotrons which accelerate protons on thick Beryllium targets. This report surveys the available experimental data of the 9 Be(p,n) reaction (cross sections, neutron spectra, yields, mean neutron energies) from the threshold to the proton energy Esub(p)=120 MeV and the works using this reaction in dosimetry measurements, with an emphasis on the data since 1977

  12. Manual on mutation breeding. 2. ed.

    International Nuclear Information System (INIS)

    1977-01-01

    The manual is a compilation of work done on the use of induced mutations in plant breeding, and presents general methods and techniques in this field. The use of chemical mutagens and ionizing radiations (X-rays, gamma rays, α- and β-particles, protons, neutrons) are described as well as the effects of these mutagens. The different types of mutations achieved can be divided into genome mutations, chromosome mutations and extra nuclear mutations. Separate chapters deal with mutation techniques in breeding seed-propagated species and asexually propagated plants (examples of development of cultivars given). Plant characters which can be improved by mutation breeding include yield, ripening time, growth habit, disease resistance and tolerance to environmental factors (temperature, salinity etc.). The use of mutagens for some specific plant breeding problems is discussed and attention is also paid to somatic cell genetics in connection with induced mutations. The manual contains a comprehensive bibliography (60 p. references) and a subject index

  13. Study on 150μm thick n- and p-type epitaxial silicon sensors irradiated with 24 GeV/c protons and 1 MeV neutrons

    International Nuclear Information System (INIS)

    Kaska, Katharina; Moll, Michael; Fahrer, Manuel

    2010-01-01

    A study on 150μm epitaxial (EPI) n- and p-type silicon diodes irradiated with neutrons up to 8x10 15 n/cm 2 and protons up to 1.7x10 15 p/cm 2 has been performed by means of CV/IV, charge collection efficiency (CCE) and transient current technique (TCT) measurements. It is found that the effective space charge density increases three times faster after proton than after neutron irradiation with a slightly higher effective space charge generation rate for n-type material compared to p-type material. A drop in charge collection efficiency already at fluences of 1x10 12 n eq /cm 2 can be seen in n-type material, but is absent in p-type material. TCT measurements show space charge sign inversion from positive to negative charge in n-type material after neutron irradiation and from negative to positive space charge in p-type material after proton irradiation. No difference was found in the response of diodes manufactured by different producers out of the same wafer material.

  14. Prompt fission neutron spectra and anti νp

    International Nuclear Information System (INIS)

    Madland, D.G.

    Methods used to obtain the evaluated prompt fisson neutron spectrum N(E) and the average prompt neutron multiplicity anti ν/sub p/ are reviewed. The relative influence of experimental data; interpolated, extrapolated, and fitted experimental data; systematics; and nuclear theory are considered for the cases where (a) abundant experimental data exist, (b) some experimental data exist, and (c) no experimental data exist. The Maxwellian and Watt distributions, and the determination of the parameters of these distributions by data fitting, are described and compared to recent new theoretical work on the calculation of N(E). Similarly, various expressions for anti γ/sub p/ that have been obtained by data fitting and systematics are described and compared to recent new theoretical work. Complications in the evaluation of N(E) and anti γ/sub p/ due to the onset of multiple-chance fission and the interrelationships between N(E), anti γΔ/sub p/ and the multiple-chance fission cross section are discussed using the example of the fission of 235 U. Some statistics and comments are given on the evaluations of N(E) and anti γ/sub p/ contained in ENDF/B-V, and a number of concluding recommendations are made for future evaluation work

  15. Calculations of the relative effectiveness of alanine for neutrons with energies up to 17.1 MeV

    International Nuclear Information System (INIS)

    Gerstenberg, H.M.; Coyne, J.J.

    1990-01-01

    The relative effectiveness (RE) of alanine has been calculated for neutrons using the RE of alanine for charged particles. The neutrons interact with one or more of the elements (hydrogen, carbon, nitrogen and oxygen) that compose the alanine. These interactions produce spectra of secondary charged particles consisting of ions of H, D, He, Be, B, C, N and O. From a combination of the calculated secondary charged particle spectra generated by the slowing down neutrons, and the calculated RE of the ions produced, a RE for the neutrons can be obtained. In addition, lineal energy spectra were determined for neutrons with energies up to 17.1 MeV interacting with alanine. An analytical code was used to calculate these spectra for a 1 μm diameter alanine cell surrounded by an alanine medium. For comparison, similar calculations were made for muscle tissue. Finally, the calculated differential RE was folded with dose distributions to obtain RE-weighted distributions for alanine. (author)

  16. Neutron spectrometry with organic scintillation detector

    International Nuclear Information System (INIS)

    Butragueno Casado, J. L.

    1972-01-01

    This work describes a fast neutron spectrometer using a stilbene crystal as head detector with pulse shape discrimination (P.S.D.) to reject gamma background. Tre experimental procedure involves the P.S.D., the measurements to calibrate the spectrometer and the corrections for several factors, mainly the non-linear response of the stilbene. Results of the measurements with the reaction D 2 (d,n)He 3 , and with an Am-Be neutron source are presented. It is also presented the measurement of the spectrum of the fast reactor CCRAl-1. (Author) 17 refs

  17. Hyper-thermal neutron irradiation field for neutron capture therapy

    International Nuclear Information System (INIS)

    Sakurai, Yoshinori; Kobayashi, Tooru; Kanda, Keiji

    1994-01-01

    The utilization of hyper-thermal neutrons, which have an energy spectrum of a Maxwell distribution higher than the room temperature of 300 K, has been studied in order to improve the thermal neutron flux distribution in a living body for a deep-seated tumor in neutron capture therapy (NCT). Simulation calculations using MCNP-V3 were carried out in order to investigate the characteristics of the hyper-thermal neutron irradiation field. From the results of simulation calculations, the following were confirmed: (i) The irradiation field of the hyper-thermal neutrons is feasible by using some scattering materials with high temperature, such as Be, BeO, C, SiC and ZrH 1.7 . Especially, ZrH 1.7 is thought to be the best material because of good characteristics of up-scattering for thermal neutrons. (ii) The ZrH 1.7 of 1200 K yields the hyper-thermal neutrons of a Maxwell-like distribution at about 2000 K and the treatable depth is about 1.5 cm larger comparing with the irradiation of the thermal neutrons of 300 K. (iii) The contamination by the secondary gamma-rays from the scattering materials can be sufficiently eliminated to the tolerance level for NCT through the bismuth layer, without the larger change of the energy spectrum of hyper-thermal neutrons. ((orig.))

  18. Amorphous-to-crystalline phase transformation by neutron irradiation of the alloy Fe/sub 83/B/sub 17/

    Energy Technology Data Exchange (ETDEWEB)

    Weis, J.; Gabris, F.; Cerven, I.; Sitek, J. (Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia))

    1984-03-01

    The purpose of the present work is to investigate the structural changes of amorphous Fe/sub 83/B/sub 17/ alloy after irradiation with fast neutrons ( > 1 MeV) and to compare with the crystallization behaviour of the amorphous Fe/sub 83/B/sub 17/ alloy after annealing. The structural changes were studied by Moessbauer spectroscopy and X-ray diffraction with the usual Fourier analysis.

  19. Pulsed neutron generator for mass flow measurement using the pulsed neutron activation technique

    International Nuclear Information System (INIS)

    Rochau, G.E.; Hornsby, D.R.; Mareda, J.F.; Riggan, W.C.

    1980-01-01

    A high-output, transportable neutron generator has been developed to measure mass flow velocities in reactor safety tests using the Pulsed Neutron Activation (PNA) Technique. The PNA generator produces >10 10 14 MeV D-T neutrons in a 1.2 millisecond pulse. The Millisecond Pulse (MSP) Neutron Tube, developed for this application, has an expected operational life of 1000 pulses, and it limits the generator pulse repetition rate to 12 pulses/minute. A semiconductor neutron detector is included in the generator package to monitor the neutron output. The control unit, which can be operated manually or remotely, also contains a digital display with a BCD output for the neutron monitor information. The digital logic of the unit controls the safety interlocks and rejects transient signals which could accidently fire the generator

  20. Neutron-to-proton ratios in pA and π+-A interactions

    International Nuclear Information System (INIS)

    Bayukov, Yu.D.; Degtyarenko, P.V.; Druzhinin, B.L.

    1983-01-01

    Measurements of neutron and proton yields at 120 deg have been carried out in 7.5 GeV/c pA and in 1.4 GeV/c and 5.0 GeV/c π +- A interactions. The ratios of secondary neutrons to protons are considered in detail. The ratios depend on kinetic energy of secondary nucleons and this dependence is more pronounced for heavy nuclei. Dependence of this ratios on the incident particle charge and the asymmetry resulting from a different number of protons and neutrons in the nucleus are discussed

  1. Angular dependence of neutron yield and of spectrum of neutrons producted in pA and π-A interactions

    International Nuclear Information System (INIS)

    Bayukov, Yu.D.; Gavrilov, V.B.; Goryainov, N.A.

    1982-01-01

    Neutron spectra are measured in the T kinetic energy range from 6 up to 20a MeV. Neutrons escape from C, Cu, Pb, U nuclei under the angles of THETA=10 deg + 160 deg in p+A → n+x reaction at 7.5 GeV/c and in π - +A → n+x reaction at 5.0 GeV/c. In the 80-200 MeV secondary neutron energy range the obtained data are compared with the results of simultaneous measurements of proton spectra. The effect of itopic symmetry of fast nucleon yield from non-symmetric nuclei are under considereation. Division of contributions of quasi-free and deep inelastic nuclear processes to fast neutron formation is carried out on the basis of the data obtained

  2. Leading neutron energy and pT distributions in deep inelastic scattering and photoproduction at HERA

    International Nuclear Information System (INIS)

    Chekanov, S.; Derrick, M.; Magill, S.

    2007-02-01

    The production of energetic neutrons in ep collisions has been studied with the ZEUS detector at HERA. The neutron energy and p T 2 distributions were measured with a forward neutron calorimeter and tracker in a 40 pb -1 sample of inclusive deep inelastic scattering (DIS) data and a 6 pb -1 sample of photoproduction data. The neutron yield in photoproduction is suppressed relative to DIS for the lower neutron energies and the neutrons have a steeper p T 2 distribution, consistent with the expectation from absorption models. The distributions are compared to HERA measurements of leading protons. The neutron energy and transverse-momentum distributions in DIS are compared to Monte Carlo simulations and to the predictions of particle exchange models. Models of pion exchange incorporating absorption and additional secondary meson exchanges give a good description of the data. (orig.)

  3. Activation measurements for fast neutrons. Part A. Sulfur (32P) activation

    International Nuclear Information System (INIS)

    Kerr, George D.

    2005-01-01

    The sulfur activation measurements at Hiroshima have been useful in refining and verifying the neutron source-term calculations for the Hiroshima bomb (Kerr and Pace 1988). For example, the Riken measurements of sulfur activation at Hiroshima were used to demonstrate that a two dimensional calculation of the neutron leakage was required for the Hiroshima bomb in order to accurately account for the blind spot in the neutron leakage through the nose of the device (Kerr 1982a,b; Kerr et al. 1983; Pace and Kerr 1984). The sulfur activation measurements at Hiroshima are discussed and compared in this section with the results of DS86 and DS02 calculations for the air-over-ground transport of neutrons at Hiroshima. (J.P.N.)

  4. ESTIMA, Neutron Width Level Spacing, Neutron Strength Function of S- Wave, P-Wave Resonances

    International Nuclear Information System (INIS)

    Fort, E.

    1982-01-01

    1 - Description of problem or function: ESTIMA calculates level spacing and neutron strength function of a mixed sequence of s- and p-wave resonances given a set of neutron widths as input parameters. Three algorithms are used, two of which calculate s-wave average parameters and assume that the reduced widths obey a Porter-Thomas distribution truncated by a minimum detection threshold. The third performs a maximum likelihood fit to a truncated chi-squared distribution of any specified number of degrees of freedom, i.e. it can be used for calculating s-wave or p-wave average parameters. Resonances of undeclared angular orbital momentum are divided into groups of probable s-wave and probable p-wave by a simple application of Bayes' Theorem. 2 - Method of solution: Three algorithms are used: i) GAMN method, based on simple moments properties of a Porter-Thomas distribution. ii) Missing Level Estimator, a simplified version of the algorithm used by the program BAYESZ. iii) ESTIMA, a maximum likelihood fit. 3 - Restrictions on the complexity of the problem: A maximum of 400 resonances is allowed in the version available from NEADB, however this restriction can be relaxed by increasing array dimensions

  5. Determination of the fast neutrons spectra by the Elastic scattering method (n, p); Determinacion del espectro de neutrones rapidos por el metodo de la dispersion elastica (n, p)

    Energy Technology Data Exchange (ETDEWEB)

    Elizalde D, J

    1973-07-01

    This work consists in determining the fast neutron spectra emitted by a Pu-Be isotopic source. The implemented technique is based in the spectrometry (n, p). This consists in making to fall on a fast neutrons beams (polyenergetic) over a thin film of hydrogenated material, detecting the spectra of emitted protons at a fix angle. The polyethylene film and the used solid state detector are inside of a vacuum chamber. The detector is placed at 30 degree with respect to direction of the incident neutrons beam. The protons spectra is stored in a multichannel. the energy is obtained with the prior calibration of the system. The data processing involves the transformation of the protons spectra observed at the falling on neutrons spectra over the film. The energy of the neutrons is related with that of the protons, according to the collision kinematical equations. The cross section of elastic collision of the neutrons with the hydrogen atoms is obtained from literature. Applying these relations to the observed spectra it is obtained the falling on neutron spectra over the film. (Author)

  6. Effect of reactor neutron radiation and temperature on the structure of InP single crystals

    International Nuclear Information System (INIS)

    Bojko, V.M.; Kolin, N.G.; Merkurisov, D.I.; Bublik, V.T.; Voronova, M.I.; Shcherbachev, K.D.

    2006-01-01

    The structural characteristics of InP single crystals have been investigated depending on the radiation effects produced by fast and full spectrum neutrons and subsequent heat treatment. A lattice period in InP single crystals decreases under neutron irradiation. Fast neutrons make the main contribution into the change of the lattice period. Availability of the thermal neutrons initiates the formation of Sn atoms, but does not make a significant influence on the change of the lattice period. Heat treatment of the irradiated samples up to 600 deg C causes the annealing of radiation defects and recovery of the lattice period. With increasing neutron fluences a lattice period becomes even higher than before irradiation [ru

  7. Radiative capture of neutrons by deuterons n+d → 3H+γ and P-odd nuclear forces

    International Nuclear Information System (INIS)

    Rekalo, M.P.

    1987-01-01

    P odd polarization phenomena in neutron radiative capture with deuterons, n+d → 3 H+γ have been studied. It is shown, that in a general case during collisions of arbitrarily polarized neutrons with a deuteron target characterized with vector and tensor polarizations, 18 different P odd asymmetries of gamma quanta angular distribution appear. P odd contribution to density matrix of gamma quanta produced in polarized neutron capture with nonpolarized deuterons is determined by 8 substantial structural functions and P odd dependence of photon Stokes parameters on deuteron tensor polarization is characterized in a general case with ten structure functions. The number of P odd correlations decreases when capturing slow neutrons

  8. Neutron and P, T symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Y [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1996-05-01

    New ideas for experiments to improve the T-violation limit by a factor of 10 to 100 is discussed for a intensive spallation neutron source. The methods to improve the limit of the right-handed current and the neutron lifetime are also discussed. (author)

  9. Comparative Study between Sequential Automatic and Manual Home Respiratory Polygraphy Scoring Using a Three-Channel Device: Impact of the Manual Editing of Events to Identify Severe Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    Glenda Ernst

    2015-01-01

    Full Text Available Objective. According to current guidelines, autoscoring of respiratory events in respiratory polygraphy requires manual scoring. The aim of this study was to evaluate the agreement between automatic analysis and manual scoring to identify patients with suspected OSA. Methods. This retrospective study analyzed 791 records from respiratory polygraphy (RP performed at home. The association grade between automatic scoring and manual scoring was evaluated using Kappa coefficient and the agreement using Bland and Altman test and intraclass correlation coefficient (CCI. To determine the accuracy in the identification of AHI≥30 eV/h, the ROC curve analysis was used. Results. The population analyzed consisted of 493 male (62.3% and 298 female patients, with an average age of 54.7±14.20 years and BMI of 32.7±8.21 kg/m2. There was no significant difference between automatic and manual apnea/hypopnea indexes (aAHI, mAHI: aAHI 17.25 (SD: 17.42 versus mAHI 21.20±7.96 (p; NS. The agreement between mAHI and aAHI to AHI≥30 was 94%, with a Kappa coefficient of 0.83 (p<0.001 and a CCI of 0.83. The AUC-ROC, sensitivity, and specificity were 0.99 (CI 95%: 0.98-0.99, p<0.001, 86% (CI 95%: 78.7–91.4, and 97% (CI 95%: 96–98.3, respectively. Conclusions. We observed good agreement between automatic scoring and sequential manual scoring to identify subjects with AHI≥30 eV/h.

  10. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Torii, Yoshiya [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  11. RRFC hardware operation manual

    International Nuclear Information System (INIS)

    Abhold, M.E.; Hsue, S.T.; Menlove, H.O.; Walton, G.

    1996-05-01

    The Research Reactor Fuel Counter (RRFC) system was developed to assay the 235 U content in spent Material Test Reactor (MTR) type fuel elements underwater in a spent fuel pool. RRFC assays the 235 U content using active neutron coincidence counting and also incorporates an ion chamber for gross gamma-ray measurements. This manual describes RRFC hardware, including detectors, electronics, and performance characteristics

  12. Neutron activation in EBT-P

    International Nuclear Information System (INIS)

    Driemeyer, D.E.

    1983-01-01

    Neutron activation due to photoneutron production in the lead shields proposed to protect the EBT-P superconducting coils from excessive x-ray heating was investigated. The photoneutron flux distribution in various EBT-P structural components was calculated for typical upgrade operating conditions using a standard two-dimensional transport model (TWOTRAN). Activity levels were then evaluated for major structural materials using activation cross sections tabulated in the GAMMON library. Activation dose rates in the device enclosure following several days of 8h/day upgrade (90GHz) operation were found to be approx. 6 mrem/h, decaying to <0.25 mrem/h in approx. 3 days. This requires radiation monitoring of all personnel entering the device enclosure during this time, but should not generally restrict hands on access to the device. There is thus no strong motivation to replace lead with another shield material; however, it may be desirable to borate the enclosure walls in order to reduce the effect which impurities might have on activity levels

  13. Validating (d,pγ) as a surrogate for neutron capture

    International Nuclear Information System (INIS)

    Ratkiewicz, A.; Cizewski, J. A.; Pain, S. D.; Adekola, A. S.; Burke, J. T.; Casperson, R. J.; Fotiadis, Nikolaos; McCleskey, M.; Burcher, S.; Shand, C. M; Austin, R. A. E.; Baugher, T.; Carpenter, M. P.; Devlin, Matthew James; Escher, J. E.; Hardy, S.; Hatarik, R.; Howard, M. E.; Hughes, R. O.; Jones, K. L.; Kozub, R. L.; Lister, C. J.; Manning, B.; O'Donnell, John M.; Peters, W. A.; Ross, T. J.; Scielzo, N. D.; Seweryniak, D.; Zhu, S.

    2015-01-01

    The r-process is responsible for creating roughly half of the elements heavier than iron. It has recently become understood that the rates at which neutron capture reactions proceed at late times in the r-process may dramatically affect the final abundance pattern. However, direct measurements of neutron capture reaction rates on exotic nuclei are exceptionally difficult, necessitating the development of indirect approaches such as the surrogate technique. The (d,pγ) reaction at low energies was identified as a promising surrogate for the (n,γ) reaction, as both reactions share many characteristics. We report on a program to validate (d,pγ) as a surrogate for (n,γ) using 95Mo as a target. The experimental campaign includes direct measurements of the γ-ray intensities from the decay of excited states populated in the 95Mo(n,γ) and 95Mo(d,pγ) reactions.

  14. Neutron metrology file NMF-90. An integrated database for performing neutron spectrum adjustment calculations

    International Nuclear Information System (INIS)

    Kocherov, N.P.

    1996-01-01

    The Neutron Metrology File NMF-90 is an integrated database for performing neutron spectrum adjustment (unfolding) calculations. It contains 4 different adjustment codes, the dosimetry reaction cross-section library IRDF-90/NMF-G with covariances files, 6 input data sets for reactor benchmark neutron fields and a number of utility codes for processing and plotting the input and output data. The package consists of 9 PC HD diskettes and manuals for the codes. It is distributed by the Nuclear Data Section of the IAEA on request free of charge. About 10 MB of diskspace is needed to install and run a typical reactor neutron dosimetry unfolding problem. (author). 8 refs

  15. Angular distributions of fast neutrons scattered by Al, Si, P, S and Zn; Distributions angulaires des neutrons rapides diffuses par Al, Si, P, S et Zn; Usloviya raspredeleniya bystrykh nejtronov, rasseyannykh alyuminiem, kremniem, fosforom i tsinkom; Distribuciones angulares de neutrones rapidos dispersados por Al, Si, P, S y Zn

    Energy Technology Data Exchange (ETDEWEB)

    Tstjkaija, K; Tanaka, S; Maeuyama, M; Tomita, Y [Japan Atomic Energy Research Institute, Tokai-Mtjea (Japan)

    1962-03-15

    Differential scattering cross-sections of Al, Si, P, S and Zn for fast neutrons have been measured in an energy range of 3.4 to 4.6 MeV by using the time-of-flight method. Angular distributions of the inelastically scattered neutrons are nearly isotropic in all cases. These results are discussed on the basis of the Hauser-Feshbach theory. (author) [French] Les sections efficaces differentielles de diffusion de Al, Si, P, S et Zn pour des neutrons rapides ont ete mesurees dans la gamme d'energies de 3,4 a 4,6 MeV, en employant la methode du temps de vol. Les distributions angulaires des neutrons diffuses inelastiquement sont presque isotropes dans tous les cas. Les auteurs analysent ces resultats en se fondant sur la theorie de Hauser-Feshbach. (author) [Spanish] Los autores han medido por el metodo del tiempo de vuelo las secciones eficaces diferenciales de dispersion del Al, Si, P, S y Zn para neutrones rapidos de energia comprendida entre 3,4 y 4,6 MeV. Las distribuciones angulares de los neutrones dispersados inelasticamente son casi isotropicas en todos los casos. Los autores analizan los resultados obtenidos basandose en la teoria de Hauser-Feshbach . (author) [Russian] Differentsial'no e sechenie rasseyaniya alyuminiya, kremniya, fosfora, sery i tsinka dlya bystrykh nejtronov izmereno v diapazone ehnergii ot 3,4 do 4,6 Megaehlektronvol't ispol'zovanie m metoda vremeni proleta. Uglovye raspredeleniya neuprugo rasseyannykh nejtronov yavlyayutsya pochti vo vsekh sluchayakh izotropnymi. Jeti rezul'taty obsuzhdayutsya na osnove teorii Hauzera-Feshbakha. (author)

  16. PRISMA single crystal cold neutron spectrometer and diffractometer. User manual

    International Nuclear Information System (INIS)

    Harris, M.; Bull, M.

    1998-01-01

    PRISMA has undergone a complete rebuild since the First Edition of this manual, resulting in a rather different instrument to that of January 1995. Now that the development of the instrument has reached a quiescent stage, this new edition of the manual describes the operation of PRISMA for the foreseeable future

  17. Multigroup neutron transport equation in the diffusion and P{sub 1} approximation

    Energy Technology Data Exchange (ETDEWEB)

    Obradovic, D [Boris Kidric Institute of nuclear sciences Vinca, Belgrade (Yugoslavia)

    1970-07-01

    Investigations of the properties of the multigroup transport operator, width and without delayed neutrons in the diffusion and P{sub 1} approximation, is performed using Keldis's theory of operator families as well as a technique . recently used for investigations into the properties of the general linearized Boltzmann operator. It is shown that in the case without delayed neutrons, multigroup transport operator in the diffusion and P{sub 1} approximation possesses a complete set of generalized eigenvectors. A formal solution to the initial value problem is also given. (author)

  18. Effect of neutron irradiation on p-type silicon

    International Nuclear Information System (INIS)

    Sopko, B.

    1973-01-01

    The possibilities are discussed of silicon isotope reactions with neutrons of all energies. In the reactions, 30 Si is converted to a stable phosphorus isotope forming n-type impurities in silicon. The above reactions proceed as a result of thermal neutron irradiation. An experiment is reported involving irradiation of two p-type silicon single crystals having a specific resistance of 2000 ohm.cm and 5000 to 20 000 ohm.cm, respectively, which changed as a result of irradiation into n-type silicon with a given specific resistance. The specific resistance may be pre-calculated from the concentration of impurities and the time of irradiation. The effects of irradiation on other silicon parameters and thus on the suitability of silicon for the manufacture of semiconductor elements are discussed. (J.K.)

  19. Radiological safety aspects of the operation of neutron generators

    International Nuclear Information System (INIS)

    Boggs, R.F.

    1976-01-01

    The purpose of the manual is to provide some basic guidelines to persons with a minimum of training in radiological health or health physics, on some safety aspects of the operation of sealed-tube and Cockcroft-Walton type neutron generators. The manual does not state rules or regulations but presents a description of the most likely hazards. It is relevant to those relatively compact neutron generators which usually operate at less than 150-200 kV for the purpose of producing 14-MeV neutrons. The scope is limited to basic discussions of hazards and measurement techniques. Separate chapters are devoted to the characteristics and use of neutron generators; radiation hazards and safety considerations; radiation monitoring and interpretation of measurements; and requirements for an effective safety programme. Two appendices deal with non-radiation hazards and safety considerations, and with a neutron generator laboratory, respectively. An extensive list of bibliographic references is included

  20. Behavior of radioisotope in liquid neutron irradiated Pb-17Li eutectic

    International Nuclear Information System (INIS)

    Tebus, V.N.; Aksenov, B.S.; Klabukov, U.G.

    1994-01-01

    Investigation of radioisotope 210 Po evaporation from liquid neutron irradiated Pb- 17 Li eutectic has been performed by Knudsen method. Equilibrium 210 Po vapor pressures at temperatures 250-700 degrees C were found about 3-4 orders of magnitude less than that for pure Po and were closed to equilibrium vapor pressures of Po-Pb compound. It was proposed Po forms stable Po-Pb compounds in eutectic at temperatures up to 750-800 degrees C. But disintegrates during long storage owing to self irradiation. It was determined Po aerosol transfer with radio gases takes place at the melting period. Contamination is happened also under irradiated eutectic storage at room temperature owing to aggregate recoil characteristic of Po

  1. s- and p-wave neutron spectroscopy. Xc. Intermediate structure: 88Sr

    International Nuclear Information System (INIS)

    Malan, J.G.; Pineo, W.F.E.; Divadeenam, M.; Choi, B.H.; Bilpuch, E.G.; Newson, H.W.

    1975-01-01

    Neutron total cross section measurements of natural Sr were made from 50-875 keV using a high resolution proton beam and the 7 Li(p,n) reaction as a neutron source. These data were analyzed with the help of an R-Matrix code to extract resonance (energies and other) parameters up to about 850 keV. 2p-1h and particle-vibration doorway interpretation of the s-,p- and d-wave resonances is attempted in terms of the sum rule Σγ/subn/ 2 =γ/subd/ 2 . Predictions based on both of these models agree with the experimental results. As expected the p-wave resonances are stronger than either s- and d-wave structure. Theory accounts for the p-wave strength remarkably well. Possible location of the p-wave s.p. resonance is reproduced with a real potential and its damping due to the imaginary potential is calculated. More fragmentation of the strong p-wave doorways is observed than was expected for a compound nucleus so near 90 Zr, but a larger strength function is observed, apparently due to the p-wave giant resonance. (U.S.)

  2. Leading neutron energy and p{sub T} distributions in deep inelastic scattering and photoproduction at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Chekanov, S.; Derrick, M.; Magill, S. [Argonne National Laboratory, Argonne, IL (US)] (and others)

    2007-02-15

    The production of energetic neutrons in ep collisions has been studied with the ZEUS detector at HERA. The neutron energy and p{sub T}{sup 2} distributions were measured with a forward neutron calorimeter and tracker in a 40 pb{sup -1} sample of inclusive deep inelastic scattering (DIS) data and a 6 pb{sup -1} sample of photoproduction data. The neutron yield in photoproduction is suppressed relative to DIS for the lower neutron energies and the neutrons have a steeper p{sub T}{sup 2} distribution, consistent with the expectation from absorption models. The distributions are compared to HERA measurements of leading protons. The neutron energy and transverse-momentum distributions in DIS are compared to Monte Carlo simulations and to the predictions of particle exchange models. Models of pion exchange incorporating absorption and additional secondary meson exchanges give a good description of the data. (orig.)

  3. Ramsauer effect in triplet neutron-neutron scattering

    International Nuclear Information System (INIS)

    Pupyshev, V.V.; Solovtsova, O.P.

    1995-01-01

    As we show, due to interplay of pure nuclear and magnetic moment interactions, the total cross section of triplet neutron-neutron scattering should possess a non-zero limit at E cm = 0 and a local minimum at ∼ 20 keV. 17 refs., 1 fig

  4. Fast-neutron coincidence-counter manual

    International Nuclear Information System (INIS)

    Ensslin, N.; Atwell, T.L.; Lee, D.M.; Erkkila, B.; Marshall, R.S.; Morgan, A.; Shonrock, C.; Tippens, B.; Van Lyssel, T.

    1982-03-01

    The fast neutron counter (FNC) described in this report is a computer-based assay system employing fast-pulse counting instrumentation. It is installed below a glove box in the metal electrorefining area of the Los Alamos National Laboratory Plutonium Processing Facility. The instrument was designed to assay plutonium salts and residues from this process and to verify the mass of electrorefined metal. Los Alamos National Laboratory Groups Q-1, Q-3, and CMB-11 carried out a joint test and evaluation plan of this instrument between May 1978 and May 1979. The results of that evaluation, a description of the FNC, and operating instructions for further use are given in this report

  5. Rad Chem data acquisition chassis users manual

    International Nuclear Information System (INIS)

    Jones, B.A.

    1980-01-01

    The Shiva Laser at LLL requires many forms of diagnostics to measure and analyze fusion experiments. This manual describes the operation of a Micro-Processor controlled data acquisition system designed at LLL to measure Neutron Activation during fusion experiments on the Shiva Laser

  6. Computer program /P1-GAS/ calculates the P-0 and P-1 transfer matrices for neutron moderation in a monatomic gas

    Science.gov (United States)

    Collier, G.; Gibson, G.

    1968-01-01

    FORTRAN 4 program /P1-GAS/ calculates the P-O and P-1 transfer matrices for neutron moderation in a monatomic gas. The equations used are based on the conditions that there is isotropic scattering in the center-of-mass coordinate system, the scattering cross section is constant, and the target nuclear velocities satisfy a Maxwellian distribution.

  7. Verification of neutron pad and 17 x 7 guide tube designs by preoperational tests on the Trojan I power plant

    International Nuclear Information System (INIS)

    Bloyd, C.N.; Singleton, N.R.; Ciaramitaro, W.

    1976-05-01

    The internals vibration measurement program carried out on the Trojan-1 reactor during preoperational testing is described. The flow induced response of a 17 x 17 guide tube and the neutron pad core barrel were deduced from the plant test data and compared with the expected responses. The results showed good agreement with expected vibration levels

  8. ARIES NDA Robot operators' manual

    International Nuclear Information System (INIS)

    Scheer, N.L.; Nelson, D.C.

    1998-05-01

    The ARIES NDA Robot is an automation device for servicing the material movements for a suite of Non-destructive assay (NDA) instruments. This suite of instruments includes a calorimeter, a gamma isotopic system, a segmented gamma scanner (SGS), and a neutron coincidence counter (NCC). Objects moved by the robot include sample cans, standard cans, and instrument plugs. The robot computer has an RS-232 connection with the NDA Host computer, which coordinates robot movements and instrument measurements. The instruments are expected to perform measurements under the direction of the Host without operator intervention. This user's manual describes system startup, using the main menu, manual operation, and error recovery

  9. ENDF/B-5 formats manual 1984

    Energy Technology Data Exchange (ETDEWEB)

    Kinsey, R; Magurno, B A

    1986-09-01

    The ENDF-5 Format, originally the format of the US Evaluated Nuclear Data File ENDF/B-5, was internationally recommended for the computer storage, processing and exchange of evaluated neutron nuclear data. The present document contains the original Formats Manual of 1979, updated with revisions of Nov. 1983. (author) Figs, tabs

  10. p and d wave neutron strength functions for rare earth nuclei

    International Nuclear Information System (INIS)

    Kononov, V.N.; Yurlov, B.D.

    1978-01-01

    The authors obtained p and d wave neutron strength functions by analysis of average fast neutron radiative capture cross-sections for the isotopes sup(142, 144, 146, 148, 150)Nd, sup(144, 147, 148, 149, 150, 152, 154)Sm, sup(151, 153)Eu, sup(156, 158, 160)Gd and sup(166, 168, 170)Er. The data are compared with results obtained by other authors, with calculations based on the optical model and with computations based on the semi-microscopic approach. (author)

  11. Experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source spectrum of the NBSR reactor at the NIST Center for Neutron Research

    Science.gov (United States)

    Cook, J. C.; Barker, J. G.; Rowe, J. M.; Williams, R. E.; Gagnon, C.; Lindstrom, R. M.; Ibberson, R. M.; Neumann, D. A.

    2015-08-01

    The recent expansion of the National Institute of Standards and Technology (NIST) Center for Neutron Research facility has offered a rare opportunity to perform an accurate measurement of the cold neutron spectrum at the exit of a newly-installed neutron guide. Using a combination of a neutron time-of-flight measurement, a gold foil activation measurement, and Monte Carlo simulation of the neutron guide transmission, we obtain the most reliable experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source brightness to date. Time-of-flight measurements were performed at three distinct fuel burnup intervals, including one immediately following reactor startup. Prior to the latter measurement, the hydrogen was maintained in a liquefied state for an extended period in an attempt to observe an initial radiation-induced increase of the ortho (o)-hydrogen fraction. Since para (p)-hydrogen has a small scattering cross-section for neutron energies below 15 meV (neutron wavelengths greater than about 2.3 Å), changes in the o- p hydrogen ratio and in the void distribution in the boiling hydrogen influence the spectral distribution. The nature of such changes is simulated with a continuous-energy, Monte Carlo radiation-transport code using 20 K o and p hydrogen scattering kernels and an estimated hydrogen density distribution derived from an analysis of localized heat loads. A comparison of the transport calculations with the mean brightness function resulting from the three measurements suggests an overall o- p ratio of about 17.5(±1) % o- 82.5% p for neutron energies<15 meV, a significantly lower ortho concentration than previously assumed.

  12. Experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source spectrum of the NBSR reactor at the NIST Center for Neutron Research

    Energy Technology Data Exchange (ETDEWEB)

    Cook, J.C.; Barker, J.G.; Rowe, J.M.; Williams, R.E. [NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 6100, Gaithersburg, MD 20899-6100 (United States); Gagnon, C. [Department of Materials Science and Engineering, University of Maryland, College Park, MD 20742 (United States); Lindstrom, R.M. [Scientist Emeritus, Chemical Sciences Division, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 8395, Gaithersburg, MD 20899-8395 (United States); Ibberson, R.M.; Neumann, D.A. [NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 6100, Gaithersburg, MD 20899-6100 (United States)

    2015-08-21

    The recent expansion of the National Institute of Standards and Technology (NIST) Center for Neutron Research facility has offered a rare opportunity to perform an accurate measurement of the cold neutron spectrum at the exit of a newly-installed neutron guide. Using a combination of a neutron time-of-flight measurement, a gold foil activation measurement, and Monte Carlo simulation of the neutron guide transmission, we obtain the most reliable experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source brightness to date. Time-of-flight measurements were performed at three distinct fuel burnup intervals, including one immediately following reactor startup. Prior to the latter measurement, the hydrogen was maintained in a liquefied state for an extended period in an attempt to observe an initial radiation-induced increase of the ortho (o)-hydrogen fraction. Since para (p)-hydrogen has a small scattering cross-section for neutron energies below 15 meV (neutron wavelengths greater than about 2.3 Å), changes in the o- p hydrogen ratio and in the void distribution in the boiling hydrogen influence the spectral distribution. The nature of such changes is simulated with a continuous-energy, Monte Carlo radiation-transport code using 20 K o and p hydrogen scattering kernels and an estimated hydrogen density distribution derived from an analysis of localized heat loads. A comparison of the transport calculations with the mean brightness function resulting from the three measurements suggests an overall o- p ratio of about 17.5(±1) % o- 82.5% p for neutron energies<15 meV, a significantly lower ortho concentration than previously assumed.

  13. SHARP User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay S. [Argonne National Lab. (ANL), Argonne, IL (United States); Rahaman, Ronald O. [Argonne National Lab. (ANL), Argonne, IL (United States); Solberg, Jerome [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-31

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  14. SHARP User Manual

    International Nuclear Information System (INIS)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.; Mahadevan, Vijay S.; Rahaman, Ronald O.; Solberg, Jerome

    2016-01-01

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  15. Comparative analysis between P1 and B1 equations for neutron moderation

    International Nuclear Information System (INIS)

    Martinez, Aquilino Senra; Silva, Fernando Carvalho da; Cardoso, Carlos Eduardo Santos

    2000-01-01

    In order to calculate the neutron flux in nuclear reactors, B1 or P1 equations are solved by numerical methods for several groups of energy. The neutron fluxes obtained from the solutions of the B1 and P1 equations are similar when they are applied to large nuclear power reactors. However, an important difference between the two fluxes is that the system of P1 equations uses one more approximation than the B1 system and then, its flux is less precise. The present work shows the relations between both equations and analyzes for what conditions the two equations systems are equivalent. Furthermore, this equations are numerically solved in 54 groups of energy for a quadrangular arrange. (author)

  16. Manual for the Portable Handheld Neutron Counter (PHNC) for Neutron Survey and the Measurement of Plutonium Samples

    International Nuclear Information System (INIS)

    Menlove, H.O.

    2005-01-01

    We have designed a portable neutron detector for passive neutron scanning measurement and coincidence counting of bulk samples of plutonium. The counter will be used for neutron survey applications as well as the measurement of plutonium samples for portable applications. The detector uses advanced design 3 He tubes to increase the efficiency and battery operated shift register electronics. This report describes the hardware, performance, and calibration for the system

  17. Determination of the fast neutrons spectra by the Elastic scattering method (n, p)

    International Nuclear Information System (INIS)

    Elizalde D, J.

    1973-01-01

    This work consists in determining the fast neutron spectra emitted by a Pu-Be isotopic source. The implemented technique is based in the spectrometry (n, p). This consists in making to fall on a fast neutrons beams (polyenergetic) over a thin film of hydrogenated material, detecting the spectra of emitted protons at a fix angle. The polyethylene film and the used solid state detector are inside of a vacuum chamber. The detector is placed at 30 degree with respect to direction of the incident neutrons beam. The protons spectra is stored in a multichannel. the energy is obtained with the prior calibration of the system. The data processing involves the transformation of the protons spectra observed at the falling on neutrons spectra over the film. The energy of the neutrons is related with that of the protons, according to the collision kinematical equations. The cross section of elastic collision of the neutrons with the hydrogen atoms is obtained from literature. Applying these relations to the observed spectra it is obtained the falling on neutron spectra over the film. (Author)

  18. Thermonuclear reaction rate of 17O(p,γ)18F

    International Nuclear Information System (INIS)

    Fox, C.; Iliadis, C.; Champagne, A.E.; Fitzgerald, R.P.; Longland, R.; Newton, J.; Pollanen, J.; Runkle, R.

    2005-01-01

    The 17 O(p,γ) 18 F and 17 O(p,α) 14 N reactions have a profound influence on hydrogen-burning nucleosynthesis in a number of stellar sites, including red giants, asymptotic giant branch (AGB) stars, massive stars, and classical novae. Previously evaluated thermonuclear rates for both reactions carry large uncertainties. We investigated the proton-capture reaction on 17 O in the bombarding energy range of E p lab = 180-540 keV. We observed a previously undiscovered resonance at E R lab = 193.2 ± 0.9 keV. The resonance strength amounts to (ωγ) pγ (1.2±0.2)x10 -6 eV. With this value, the uncertainties of the 17 O(p,γ) 18 F reaction rates are reduced by orders of magnitude in the peak temperature range of classical novae (T=0.1-0.4 GK). We also report on a reevaluation of the 17 O(p,γ) 18 F reaction rates at lower temperatures that are pertinent to red giants, AGB stars, or massive stars. The present work establishes the 17 O(p,γ) 18 F reaction rates over a temperature range of T= 0.01-1.5 GK with statistical uncertainties of 10-50%. The new recommended reaction rates deviate from the previously accepted values by an order of magnitude around T≅0.2 GK and by factors of 2-3 at T < 0.1 GK

  19. Silicon diode measurements for monoenergetic neutrons and critical assemblies (H.P.R.R. and VIPER)

    International Nuclear Information System (INIS)

    Delafield, H.J.; Reading, A.H.

    1981-04-01

    The response of the silicon diode (AEI FNDD1) has been measured for monoenergetic neutrons of mean energies 0.56, 2.00 and 3.68 MeV. Using conversion factors from neutron fluence to kerma (ICRU, 1977) it is shown that the theoretical kerma response in muscle tissue is substantially uniform (+- 20%) over the neutron energy range from 250 keV to 17 MeV. Diode measurements were made at the Health Physics Research Reactor at the Oak Ridge National Laboratory, Tennessee, U.S.A., during the 1979 international intercomparison of nuclear accident dosimetry systems. Measurements of kerma in free air and of the surface absorbed dose on the front surface of a phantom were made with the reactor bare, shielded by 20 cm concrete and by 5 cm steel. Further tests were made at the VIPER reactor at AWRE. These diode measurements, covering a range of neutron spectra, were in good agreement (+- 20%) with measurements made by the threshold detector system. (author)

  20. Shell model description of 16O(p,γ)17F and 16O(p,p)16O reactions

    International Nuclear Information System (INIS)

    Bennaceur, K.; Michel, N.; Okolowicz, J.; Ploszajczak, M.; Bennaceur, K.; Nowacki, F.; Okolowicz, J.

    2000-01-01

    We present shell model calculations of both the structure of 17 F and the reactions 16 O(p,γ) 17 F, 16 O(p,p) 16 O. We use the ZBM interaction which provides a fair description of the properties of 16 O and neighbouring nuclei and, in particular it takes account for the complicated correlations in coexisting low-lying states of 16 O. (authors)

  1. An automatic evaluation system for NTA film neutron dosimeters

    CERN Document Server

    Müller, R

    1999-01-01

    At CERN, neutron personal monitoring for over 4000 collaborators is performed with Kodak NTA films, which have been shown to be the most suitable neutron dosimeter in the radiation environment around high-energy accelerators. To overcome the lengthy and strenuous manual scanning process with an optical microscope, an automatic analysis system has been developed. We report on the successful automatic scanning of NTA films irradiated with sup 2 sup 3 sup 8 Pu-Be source neutrons, which results in densely ionised recoil tracks, as well as on the extension of the method to higher energy neutrons causing sparse and fragmentary tracks. The application of the method in routine personal monitoring is discussed. $9 overcome the lengthy and strenuous manual scanning process with an optical microscope, an automatic analysis system has been developed. We report on the successful automatic scanning of NTA films irradiated with /sup 238/Pu-Be source $9 discussed. (10 refs).

  2. Electrical properties of InP irradiated by fast neutrons of a nuclear reactor

    International Nuclear Information System (INIS)

    Kolin, N.G.; Merkurisov, D.I.; Solov'ev, S.P.

    2000-01-01

    Electrophysical properties of InP single crystalline samples with different initial concentration of charge carriers have been studied in relation to irradiation conditions with fast neutrons of a nuclear reactor and subsequent heat treatments within the temperature range of 20-900 deg C. It has been shown that changes of the properties depend on the initial doping level. The annealing in the temperature range mentioned above results in the elimination of radiation defects. This makes possible to use the nuclear doping method for InP samples. In this respect the contribution of intermediate neutron reactions to the whole effect of the InP nuclear doping is estimated to be ∼ 10% [ru

  3. High-energy neutron dosimetry at the Clinton P. Anderson Meson Physics Facility

    International Nuclear Information System (INIS)

    Mallett, M.W.; Vasilik, D.G.; Littlejohn, G.J.; Cortez, J.R.

    1990-01-01

    Neutron energy spectrum measurements performed at the Clinton P. Anderson Meson Physics Facility indicated potential areas for high energy neutron exposure to personnel. The low sensitivity of the Los Alamos thermoluminescent dosimeter (TLD) to high energy neutrons warranted issuing a NTA dosimeter in addition to the TLD badge to employees entering these areas. The dosimeter consists of a plastic holder surrounding NTA film that has been desiccated and sealed in a dry nitrogen environment. A study of the fading of latent images in NTA film demonstrated the success of this packaging method to control the phenomenon. The Los Alamos NTA dosimeter is characterized and the fading study discussed. 10 refs., 4 figs., 2 tabs

  4. Neutron Energy Spectra and Yields from the 7Li(p,n) Reaction for Nuclear Astrophysics

    Science.gov (United States)

    Tessler, M.; Friedman, M.; Schmidt, S.; Shor, A.; Berkovits, D.; Cohen, D.; Feinberg, G.; Fiebiger, S.; Krása, A.; Paul, M.; Plag, R.; Plompen, A.; Reifarth, R.

    2016-01-01

    Neutrons produced by the 7Li(p, n)7Be reaction close to threshold are widely used to measure the cross section of s-process nucleosynthesis reactions. While experiments have been performed so far with Van de Graaff accelerators, the use of RF accelerators with higher intensities is planned to enable investigations on radioactive isotopes. In parallel, high-power Li targets for the production of high-intensity neutrons at stellar energies are developed at Goethe University (Frankfurt, Germany) and SARAF (Soreq NRC, Israel). However, such setups pose severe challenges for the measurement of the proton beam intensity or the neutron fluence. In order to develop appropriate methods, we studied in detail the neutron energy distribution and intensity produced by the thick-target 7Li(p,n)7Be reaction and compared them to state-of- the-art simulation codes. Measurements were performed with the bunched and chopped proton beam at the Van de Graaff facility of the Institute for Reference Materials and Measurements (IRMM) using the time-of-flight (TOF) technique with thin (1/8") and thick (1") detectors. The importance of detailed simulations of the detector structure and geometry for the conversion of TOF to a neutron energy is stressed. The measured neutron spectra are consistent with those previously reported and agree well with Monte Carlo simulations that include experimentally determined 7Li(p,n) cross sections, two-body kinematics and proton energy loss in the Li-target.

  5. Anisotropic kernel p(μ → μ') for transport calculations of elastically scattered neutrons

    International Nuclear Information System (INIS)

    Stevenson, B.

    1985-01-01

    Literature in the area of anisotropic neutron scattering is by no means lacking. Attention, however, is usually devoted to solution of some particular neutron transport problem and the model employed is at best approximate. The present approach to the problem in general is classically exact and may be of some particular value to individuals seeking exact numerical results in transport calculations. For attempts neutrons originally directed toward the unit vector Omega, it attempts the evaluation of p(theta'), defined such that p(theta') d theta' is that fraction of scattered neutrons that emerges in the vicinity of a cone i.e., having been scattered to between angles theta' and theta' + d theta' with the axis of preferred orientation i; Omega makes an angle theta with i. The relative simplicity of the final form of the solution for hydrogen, in spite of the complicated nature of the limits involved, is a trade-off that truly is not necessary. The exact general solution presented here in integral form, has exceedingly simple limits, i.e., 0 ≤ theta' ≤ π regardless of the material involved; but the form of the final solution is extraordinarily complicated

  6. Residual stress measurements via neutron diffraction of additive manufactured stainless steel 17-4 PH.

    Science.gov (United States)

    Masoomi, Mohammad; Shamsaei, Nima; Winholtz, Robert A; Milner, Justin L; Gnäupel-Herold, Thomas; Elwany, Alaa; Mahmoudi, Mohamad; Thompson, Scott M

    2017-08-01

    Neutron diffraction was employed to measure internal residual stresses at various locations along stainless steel (SS) 17-4 PH specimens additively manufactured via laser-powder bed fusion (L-PBF). Of these specimens, two were rods (diameter=8 mm, length=80 mm) built vertically upward and one a parallelepiped (8×80×9 mm 3 ) built with its longest edge parallel to ground. One rod and the parallelepiped were left in their as-built condition, while the other rod was heat treated. Data presented provide insight into the microstructural characteristics of typical L-PBF SS 17-4 PH specimens and their dependence on build orientation and post-processing procedures such as heat treatment. Data have been deposited in the Data in Brief Dataverse repository (doi:10.7910/DVN/T41S3V).

  7. Residual stress measurements via neutron diffraction of additive manufactured stainless steel 17-4 PH

    Directory of Open Access Journals (Sweden)

    Mohammad Masoomi

    2017-08-01

    Full Text Available Neutron diffraction was employed to measure internal residual stresses at various locations along stainless steel (SS 17-4 PH specimens additively manufactured via laser-powder bed fusion (L-PBF. Of these specimens, two were rods (diameter=8 mm, length=80 mm built vertically upward and one a parallelepiped (8×80×9 mm3 built with its longest edge parallel to ground. One rod and the parallelepiped were left in their as-built condition, while the other rod was heat treated. Data presented provide insight into the microstructural characteristics of typical L-PBF SS 17-4 PH specimens and their dependence on build orientation and post-processing procedures such as heat treatment. Data have been deposited in the Data in Brief Dataverse repository (doi:10.7910/DVN/T41S3V.

  8. Influence of production technology and design on characteristics neutron-sensitive P-I-N diodes

    International Nuclear Information System (INIS)

    Perevertaylo, V.L.; Kovrygin, V.I.

    2012-01-01

    This paper presents the results of tests on neutron-sensitive p-i-n diode with local p-n junction, which allows to measure not only the integral dose by nonionizing energy loss (NIEL), but also the real-time dose and dose rate because of ionizing energy losses (IEL). The influence of design and process parameters and the lifetime of minority carriers on the radiation characteristics of the device considered. Sensitivity at low doses (from one to ten rad) is limited due to a decrease in the lifetime because of influence of lateral sides of cut. The sensitivity and accuracy of dose can be increased by moving of p-n junction away from the cut surface. The dependence of the voltage drop across the diode on the neutron dose irradiation up to 5 krad received, and the sensitivity was 2 - 3 mV/rad. We have demonstrated that replacement of the bulk p-i-n diode with total p-n junction by new diodes with local p-n junction allow for increase sensitivity, accuracy of dose and application in NIEL and IEL measurements simultaneously. Explanation for the extinction of a direct current through the diode with increasing doses of neutron irradiation proposed

  9. NJOY nuclear data processing system: user's manual

    International Nuclear Information System (INIS)

    MacFarlane, R.E.; Barrett, R.J.; Muir, D.W.; Boicourt, R.M.

    1978-12-01

    The NJOY nuclear data processing system is a comprehensive computer code package for producing cross sections for neutron and photon transport calculations from ENDF/B-IV and -V evaluated nuclear data. This user's manual provides a concise description of the code, input instructions, sample problems, and installation instructions. 1 figure, 3 tables

  10. Neutron Scattering

    International Nuclear Information System (INIS)

    Fayer, Michael J.; Gee, Glendon W.

    2005-01-01

    The neutron probe is a standard tool for measuring soil water content. This article provides an overview of the underlying theory, describes the methodology for its calibration and use, discusses example applications, and identifies the safety issues. Soil water makes land-based life possible by satisfying plant water requirements, serving as a medium for nutrient movement to plant roots and nutrient cycling, and controlling the fate and transport of contaminants in the soil environment. Therefore, a successful understanding of the dynamics of plant growth, nutrient cycling, and contaminant behavior in the soil requires knowledge of the soil water content as well as its spatial and temporal variability. After more than 50 years, neutron probes remain the most reliable tool available for field monitoring of soil water content. Neutron probes provide integrated measurements over relatively large volumes of soil and, with proper access, allow for repeated sampling of the subsurface at the same locations. The limitations of neutron probes include costly and time-consuming manual operation, lack of data automation, and costly regulatory requirements. As more non-radioactive systems for soil water monitoring are developed to provide automated profiling capabilities, neutron-probe usage will likely decrease. Until then, neutron probes will continue to be a standard for reliable measurements of field water contents in soils around the globe

  11. Resonance phase and sings of P-odd and P-even effects, observable in the reactions with neutrons

    International Nuclear Information System (INIS)

    Smotritskij, L.M.

    2002-01-01

    It is shown that introduction of the resonance phase for two quasistationary states with a similar spin and counter parity makes it possible to correlate the sing dependence of both the P-odd and P-even effects, experimentally observed in the reactions with neutrons. The common description of such effects enables determination of the theory unknown (free) parameters from the experiment [ru

  12. Dissolving mechanism of strain P17 on insoluble phosphorus of yellow-brown soil

    Directory of Open Access Journals (Sweden)

    Zhong Chuan-qing

    2014-09-01

    Full Text Available Strain P17 was a bacterial strain identified as Bacillus megaterium isolated from ground accumulating phosphate rock powder. The fermentation broth of strain P17 and the yellow-brown soil from Nanjing Agricultural University garden were collected to conduct this study. The simulation of fixed insoluble phosphorous forms after applying calcium superphosphate into yellow-brown soil was performed in pots, while available P and total P of soil were extremely positive correlative with those of groundwater. Then the dissolving effect of strain P17 on insoluble P of yellow-brown soil was studied. Results showed that Bacillus megaterium strain P17 had notable solubilizing effect on insoluble phosphates formed when too much water-soluble phosphorous fertilizer used. During 100 days after inoculation, strain P17 was dominant. Until the 120th day, compared with water addition, available P of strain P17 inoculation treated soil increased by 3 times with calcium superphosphate addition. Besides available P, pH, activity of acid and alkaline phosphatase and population of P-solubilizing microbes were detected respectively. P-solubilizing mechanism of P-solubilizing bacteria strain P17 seems to be a synergetic effect of pH decrease, organic acids, phosphatase, etc.

  13. Study on the aligned uranium-235 nuclear decay in the neutron energy range of 1.7 eV - 2.15 keV

    International Nuclear Information System (INIS)

    Danelyan, L.S.; Zakharov, Yu.V.; Zykov, V.M.; Mostovoj, V.I.; Stolyarov, V.A.; Biryukov, S.A.; Zysina, N.Yu.; Osochnikov, A.A.; Svettsov, A.V.

    1983-01-01

    Using a time-of-flight neutron spectrometer comparative measurements of intensity of fission reaction on the aligned and non-oriented uranium-235 nuclei have been performed in order to identify the resonances caused by p-neutron capture as well as to determine the p-neutron contribution to the fission cross section in the region of unresolved resonances. In some isolated resonances differences in cross sections on aligned and non-oriented nuclei of about 10% have been observed which can permit to assi.on them to p-resonances. In the region of unresolved resonances in the 0.15-2.15 keV neutron energy range to the accuracy +-1% no changes in the fission cross section during the nuclear alignment have been observ

  14. Instrumentation of a manually programmed neutron diffractometer

    DEFF Research Database (Denmark)

    Hansen, K.B.; Neisig, K.E.

    1966-01-01

    This paper describes essentially the digital part of the instrumentation for a neutron diffractometer in which the measuring procedure is governed by a control unit involving a fixed number of program points. A simultaneously running test program monitors the information transfer from the data...... sources and to the print-out in table form. The experimental conditions must be set by a panel switch selected program, which allows a desired parameter program to be executed....

  15. Target spot localization at neutron producing accelerators

    International Nuclear Information System (INIS)

    Medveczki, L.; Bornemisza-Pauspertl, P.

    1980-01-01

    In the application of neutron producing accelerators it is required to know the actual position and the homogeneity of distribution of the emitted neutrons. Solid state nuclear track detectors offer a good possibility to get precise information on these without any disturbing influence on them. LR 115 2 type cellulose nitrate Kodak-Pathe Foils were irradiated with fast neutrons. When track density is higher than about 104 tracks cm -2 the damaged area can be observed with the naked eye, too. To get quantitative information the track densities were counted with manual technique. (author)

  16. User and reference manual for the KfK code INS

    International Nuclear Information System (INIS)

    Daum, E.

    1993-09-01

    The INS code (Intense Neutron Source) serves to calculate uncollided neutron flux contours, neutron flux volumes and spatial-dependent neutron flux spectra in the test cell of an intense neutron source, of the t-H 2 O or d-Li concept. With the information of the neutron flux spectra the neutron irradiation damage like displacements per atom (DPA), H- and He-production rates and the generation of foreign elements by transmutations can be calculated for any element at any position in the test cell. This manual gives an introduction into the theory of neutron flux calculation of thick targets and neutron irradiation damage calculations. It is explained how the code is working and the handling of the input and output parameters. For each application of the several code modules an example is given. The results like contours, spectra, flux volumes and damage rates are summarized in tabular form and graphically. Damage and element transmutation data have been calculated for 23 isotopes and compared with the DEMO 1st wall values. (orig./HP) [de

  17. Neutron dosimetry system SAIPS: Manual for users and programmers (Version 87-02)

    International Nuclear Information System (INIS)

    Berzonis, M.A.; Bondars, Kh.Ya.; Niedritis, A.M.

    1988-07-01

    SAIPS is a system used for neutron dosimetry by foil activation, containing a package of programs and a data base of neutron activation cross-sections. A description is given of the SAIPS indexed procedures and users language, which are designed for producing input data for programs unfolding neutron spectra from reaction rate measurements, for carrying out calculations and processing and comparing the results obtained, for utilizing the additional capabilities of the system, and for setting up a working version of the system from the magnetic tapes used for distribution. A description is given of the logical structure of the data sets containing the libraries of neutron cross-section and a priori spectra and also the libraries of calculated spectra. The annexes give examples of SAIPS in use, of the contents of the a priori spectra and neutron cross-section libraries, and of the contents of the SAIPS distribution tapes. SAIPS contains programs in PL/1 (opt), FORTRAN IV(H) and ASSEMBLER. 25 refs

  18. Research reactor operations for neutron activation analysis

    International Nuclear Information System (INIS)

    Tv'ehlov, Yu.

    2002-01-01

    The IAEA Special Manual devoted to quality control during neutron activation analysis (NAA) on research and test reactors is discussed. Three parts of the publication involve presentation of common rules for performance of NAA, quantitative and qualitative analyses, statistic and systematic errors, safety regulations and radioactive waste management. Besides, the publication contains practical manual for the performance of NAA, and examples of different NAA regulating registration forms are presented [ru

  19. Dipole polarizability and neutron skin in {sup 68}Ni

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Dominic [GSI Darmstadt (Germany); Univ. Mainz (Germany); NSCL, MSU (United States); Aumann, Thomas [TU Darmstadt (Germany); Boretzky, Konstanze [GSI Darmstadt (Germany); Collaboration: R3B-Collaboration

    2014-07-01

    The symmetry energy term E{sub sym} of the nuclear equation-of-state describes fundamental phenomena both in nuclear physics and in astrophysics. The electric dipole (E1) response of nuclei as a function of the isospin asymmetry is driven by E{sub sym} and in particular by its density dependence. Studies of the Pygmy Dipole Resonance (PDR) in exotic nuclei have been used to constrain E{sub sym} or the neutron skin thickness ΔR{sub n,p}. The electric dipole polarizability α{sub D}, being very sensitive to the low-lying E1 strength, is correlated to ΔR{sub n,p} in a robust and only moderately less model-dependent manner [PRC 81, 051303 (2010)]. Recently, for the stable nucleus, 208Pb the neutron skin thickness was extracted from the measured αD. Here, a first experimental determination of α{sub D} in an unstable nucleus and the derivation of its ΔR{sub n,p} will be reported. Coulomb excitation in inverse kinematics at the R3B-LAND setup at GSI allows for the investigation of the dipole strength distribution in the neutron-rich {sup 68}Ni covering the pygmy (PDR) and giant dipole resonance (GDR). The E1 strength distribution in the neutron-rich {sup 68}Ni covering the pygmy (PDR) and giant dipole resonance (GDR) s investigated using the R3B-LAND setup at GSI. From the E1 strength distribution in {sup 68}Ni measured using the R3B-LAND setup at GSI, the resonance parameters for the observed PDR at 9.55(17) MeV and the giant dipole resonance at 17.1(2) MeV are determined. In combination with results from Wieland et al. [PRL 102, 092502 (2009)] an unexpectedly large direct photon-decay branching ratio of 7(2) is observed for the PDR. The measured α{sub D} of 3.40(23) fm{sup 3} is compared to relativistic RPA calculations yielding ΔR{sub n,p} of 0.17(2) fm for {sup 68}Ni.

  20. Revised SNAP III Training Manual

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Calvin Elroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gonzales, Samuel M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Nelson, Mark Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rothrock, Richard Brian [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Salazar, Samuel A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sorensen, Eric Byron [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sundby, Gary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    The Shielded Neutron Assay Probe (SNAP) technique was developed to determine the leakage neutron source strength of a radioactive object. The original system consisted of an EberlineTM Mini-scaler and discrete neutron detector. The system was operated by obtaining the count rate with the EberlineTM instrument, determining the absolute efficiency from a graph, and calculating the neutron source strength by hand. In 2003 the SNAP III, shown in Figure 1, was designed and built. It required the operator to position the SNAP, and then measure the source-to-detector and detectorto- reflector distances. Next the operator entered the distance measurements and started the data acquisition. The SNAP acquired the required count rate and then calculated and displayed the leakage neutron source strength (NSS). The original design of the SNAP III is described in SNAP III Training Manual (ER-TRN-PLN-0258, Rev. 0, January 2004, prepared by William Baird) This report describes some changes that have been made to the SNAP III. One important change is the addition of a LEMO connector to provide neutron detection output pulses for input to the MC-15. This feature is useful in active interrogation with a neutron generator because the MC-15 has the capability to only record data when it is not gated off by a pulse from the neutron generator. This avoids recording of a lot of data during the generator pulses that are not useful. Another change was the replacement of the infrared RS-232 serial communication output by a similar output via a 4-pin LEMO connector. The current document includes a more complete explanation of how to estimate the amount of moderation around a neutron-emitting source.

  1. The determination of some impurities in zirconium metal by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Watterson, J.J.

    1976-01-01

    This report describes the work done on the development of an instrumental neutron-activation method for the analysis of impurities in reactor-grade zirconium. Nine samples were analysed, and the results were compared with those obtained by other techniques. No statistically significant differences were observed for ten of the twelve elements that could possibly be determined by instrumental neutron-activation analysis. Cadmium cannot be determined at the 0,5 p.p.m. level, and there is doubt about the comparative values recorded for aluminium. The precision of the measurement by direct instrumental neutron-activation analysis ranges from 1,4 per cent for tungsten to 17 per cent for chromium [af

  2. Technical advances in neutron polarimetry and studies of the (p,n) reaction in /sup 13/C

    Energy Technology Data Exchange (ETDEWEB)

    Videla, N G

    1985-01-01

    The asymmetry in the /sup 4/He(p,n vector)/sup 4/He reaction has been measured at three different incident neutron energies: 19.40; 22.85 and 27.31 MeV, and 120/sup 0/ from forward direction. Values of the asymmetry have been used to calculate the polarization of fast neutrons produced in the /sup 13/C(p,n vector)/sup 13/N. The /sup 13/C(p,n vector)/sup 13/N reaction was studied as part of a program being undertaken at the University of Manitoba Cyclotron Laboratory to study (p,n) reactions linking isobaric analog states of mirror nuclei in the energy range of 22 to 50 MeV. The study involves a comparison of the proton analyzing power A(theta), in the reaction /sup 13/C(vector p,n)/sup 13/N to the neutron polarization in the inverse reaction /sup 13/C(p,n vector)/sup 13/N. The importance of the comparison between these two observables is based in Conzett's theorem for time reversed reactions, the theorem states that the proton analyzing power in the reaction /sup 13/C(vector p,n)/sup 13/N is equal to the neutron polarization in the reaction /sup 13/C(p,n vector)/sup 13/N provided the reaction proceeds between members of an isospin doublet and when charge symmetry and time reversal invariance hold exactly. However, isospin symmetry is broken by the Coulomb interaction. So comparison of these two observables should yield information of the breaking of isospin by the Coulomb force.

  3. Neutron scattering from 12C between 15.6 and 17.3 MeV

    International Nuclear Information System (INIS)

    Chen, Z.M.; Baird, K.; Howell, C.R.; Roberts, M.L.; Tornow, W.; Walter, R.L.

    1993-01-01

    The differential cross section σ(θ) for neutron elastic scattering from 12 C and for inelastic scattering from the 4.44 MeV state was measured at 15.57, 16.75 and 17.29 MeV. The σ(θ) data, together with published analysing power A y (θ) data, were analysed in the framework of the spherical optical model and in the coupled-channels formalism. It was concluded that the present 12 C(n,n) 12 C data and published data at higher energies appear to be well suited for determining properties of valence single-particle excitations in 11 C via an iterative-moment approach or a dispersive optical-model analysis. (author)

  4. Neutron Fluence Evaluation using an Am-Be Neutron Sources Assembly and P ADC Detectors

    International Nuclear Information System (INIS)

    Seddik, U.

    2008-01-01

    An assembly of four 241 Am-Be sources has been constructed at Nuclear Reactions Unit (NRU) of Nuclear Research Center (NRU) to perform analysis of different materials using thermal and fast neutrons. In the present paper, we measure the value of transmittance (T) in percentage of etched CR-39 detectors using a spectrophotometer at different neutron fluences ,to relate the transmittance of the detector with the neutron fluence values. The exposed samples to neutrons with accumulated fluence of order between 10 10 and 10 12 cm -2 were etched for 15 time intervals between 10-600 min in 6.25 N NaOH at 70 degree C. The etched samples were analyzed using Tech 8500 II spectrophotometer. A trend of the sample transmission and the etching time is observed which is different for each fluence value. A linear relation between the transmittance decay constant and the neutron fluence is observed which could be used as a calibration to determine unknown neutron fluence

  5. Polarized neutron physics at P.S.I

    International Nuclear Information System (INIS)

    Gaillard, G.

    1990-01-01

    In this paper the characteristics of the recent polarized neutron facility using the existing unpolarized neutron beam line nE1 developed at PSI and of the future nAl beam line are given. The physics program which started in 1986 is presented

  6. EL2-related defects in neutron irradiated GaAs1/sub -x/P/sub x/ alloys

    International Nuclear Information System (INIS)

    Munoz, E.; Garcia, F.; Jimenez, B.; Calleja, E.; Gomez, A.; Alcober, V.

    1985-01-01

    The generation of EL2-related defects in GaAsP alloys by fast neutron irradiation has been studied through deep level transient spectroscopy and photocapacitance techniques. After irradiation p-n junctions were not annealed at high temperatures. In the composition range x>0.4, fast neutrons generate a broad center at E/sub c/-0.7 eV that it is suggested to belong to the EL2 family. The presence of photocapacitance quenching effects has been taken as a preliminary fingerprint to make the above assignment. From computer analysis of the nonexponential transient capacitance waveforms, evidence that neutron irradiation creates a family of midgap levels, EL2-related, is found

  7. Microdeletion in distal 17p13.1

    DEFF Research Database (Denmark)

    Zeesman, Susan; Kjaergaard, Susanne; Hove, Hanne Buciek

    2012-01-01

    Array comparative genomic hybridization has led to the identification of new syndromes by identifying genomic imbalances not detectable by standard karyotyping methods and by allowing correlations with physical findings. Deletions in the 17p13.1 region have been reported in patients with dysmorphic...

  8. Comparative analysis between P1 and B1 equations for neutron moderation; Analise comparativa entre os metodos de obtencao e das solucoes das equacoes P1 e B1 para moderacao de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Aquilino Senra; Silva, Fernando Carvalho da; Cardoso, Carlos Eduardo Santos [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2000-07-01

    In order to calculate the neutron flux in nuclear reactors, B1 or P1 equations are solved by numerical methods for several groups of energy. The neutron fluxes obtained from the solutions of the B1 and P1 equations are similar when they are applied to large nuclear power reactors. However, an important difference between the two fluxes is that the system of P1 equations uses one more approximation than the B1 system and then, its flux is less precise. The present work shows the relations between both equations and analyzes for what conditions the two equations systems are equivalent. Furthermore, this equations are numerically solved in 54 groups of energy for a quadrangular arrange. (author)

  9. Activation neutron detector

    International Nuclear Information System (INIS)

    Ambardanishvili, T.S.; Kolomiitsev, M.A.; Zakharina, T.Y.; Dundua, V.J.; Chikhladze, N.V.

    1976-01-01

    An activation neutron detector made as a moulded and cured composition of a material capable of being neutron-activated is described. The material is selected from a group consisting of at least two chemical elements, a compound of at least two chemical elements and their mixture, each of the chemical elements and their mixture, each of the chemical elements being capable of interacting with neutrons to form radioactive isotopes having different radiation energies when disintegrating. The material capable of being neutron-activated is distributed throughout the volume of a polycondensation resin inert with respect to neutrons and capable of curing. 17 Claims, No Drawings

  10. Dounreay Shuffler diagnostic software operations manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Stuewe, B.; Klosterbuer, S.; Van Lyssel, T.

    1985-07-01

    This operations manual describes the test software for the Dounreay Shuffler. The Shuffler is an assay system, controlled by a Commodore PET computer, that measures the plutonium content in leached hulls at the fuel reprocessing plant in Dounreay, Scotland. The Shuffler contains a 252 Cf neutron source that is moved between storage and irradiation locations to obtain measurement data. A stepping motor control (SMC) module operates the Shuffler and accepts commands from the PET to move the source. This manual briefly describes the Shuffler and provides details on running and using the diagnostic software program. The communications protocol for message transmittal between the PET and SMC is defined and a detailed example of message sending is presented in an appendix

  11. In Situ Proteolysis for Crystallization of Membrane Bound Cytochrome P450 17A1 and 17A2 Proteins from Zebrafish.

    Science.gov (United States)

    Lei, Li; Egli, Martin

    2016-04-01

    Fish and human cytochrome P450 (P450) 17A1 catalyze both steroid 17α-hydroxylation and 17α,20-lyase reactions. Fish P450 17A2 catalyzes only 17α-hydroxylation. Both enzymes are microsomal-type P450s, integral membrane proteins that bind to the membrane through their N-terminal hydrophobic segment, the signal anchor sequence. The presence of this N-terminal region renders expression of full-length proteins challenging or impossible. For some proteins, variable truncation of the signal anchor sequence precludes expression or results in poor expression levels. To crystallize P450 17A1 and 17A2 in order to gain insight into their different activities, we used an alternative N-terminal sequence to boost expression together with in situ proteolysis. Key features of our approach to identify crystallizable P450 fragments were the use of an N-terminal leader sequence, a screen composed of 12 proteases to establish optimal cleavage, variations of protease concentration in combination with an SDS-PAGE assay, and analysis of the resulting fragments using Edman sequencing. Described in this unit are protocols for vector preparation, expression, purification, and in situ proteolytic crystallization of two membrane-bound P450 proteins. Copyright © 2016 John Wiley & Sons, Inc.

  12. Model calculation of neutron reaction data for 31P in the energy range from 0.1 to 20 MeV

    International Nuclear Information System (INIS)

    Li Jiangting; Ge Zhigang; Sun Xiuquan

    2006-01-01

    The neutron data calculation of 31 P in the energy range from 0.1 to 20 MeV was carried out. The neutron optical potential parameters for 31 P in energy range from O.1 to 20 MeV were obtained, based on the fitting of the available neutron experimental data with the code APOM94. The DWUCK4 code was used to investigate the cross section for neutron direct inelastic scattering. The re-evaluated neutron data is based on the available measured data by using the UNF code. The theoretical results reproduce the experimental data well, and the results were given in ENDF/B-6 format. (authors)

  13. Application of Fast Neutron Activation to Determinate of N, P and K Element Contents in the Sludge

    International Nuclear Information System (INIS)

    Supriyatni E; Yazid M; Nuraini E; Sunardi

    2003-01-01

    The application of fast neutron activation to determinate of N, P and K element contents in the sludge has been performed. The aim of this research is to determine the content of N, P and K elements in the sludge for the possibility of reuse as organic fertilizer. Sludge sample was taken from waste water retainer at Bantul Waste Water Treatment Plant. The sample was dried and ground, then irradiated using 14.7 MeV fast neutron from neutron generator. Result was qualitatively and quantitatively analyses using gamma spectrometer. The result showed that the sludge contains N with energy 511 keV, P with energy 1778 keV and K with energy 1273 keV. The concentration of N is (4.101 ± 0.007) mg/g, P is = (640.510 ± 14.34) mg/g and K = (3.045 ± 0.064) mg/g. (author)

  14. The underwater coincidence counter for plutonium measurements in mixed-oxide fuel assemblies manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Menlove, H.O.; Abhold, M.; Baker, M.; Pecos, J.

    1999-01-01

    This manual describes the Underwater Coincidence Counter (UWCC) that has been designed for the measurement of plutonium in mixed-oxide (MOX) fuel assemblies prior to irradiation. The UWCC uses high-efficiency 3 He neutron detectors to measure the spontaneous-fission and induced-fission rates in the fuel assembly. Measurements can be made on MOX fuel assemblies in air or underwater. The neutron counting rate is analyzed for singles, doubles, and triples time correlations to determine the 240 Pu effective mass per unit length of the fuel assembly. The system can verify the plutonium loading per unit length to a precision of less than 1% in a measurement time of 2 to 3 minutes. System design, components, performance tests, and operational characteristics are described in this manual

  15. Gamma-ray measurements in the one-neutron knockout of {sup 17}C, {sup 19}N, {sup 21}O and {sup 25}F

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Tajes, C.; Cortina-Gil, D.; Alvarez-Pol, H.; Benjamim, E.; Benlliure, J.; Caamano, M.; Casarejos, E.; Gascon, M.; Kurtukian, T.; Perez-Loureiro, D. [Universidade de Santiago de Compostela, Departmento de Fisica de Particulas, Santiago de Compostela (Spain); Aumann, T.; Chatillon, A.; Geissel, H.; Nociforo, C.; Prochazka, A.; Simon, H.; Suemmerer, K.; Weick, H.; Winkler, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Borge, M.J.G.; Pascual-Izarra, C.; Perea, A.; Tengblad, O. [CSIC, Instituto de Estructura de la Materia, Madrid (Spain); Chulkov, L.V. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Kurchatov Institute, Moscow (Russian Federation); Eppinger, K.; Faestermann, T.; Gernhaeuser, R.; Kruecken, R.; Maierbeck, P.; Schwertel, S. [Technische Universitaet Muenchen, Physik Department E12, Garching (Germany); Jonson, B. [Chalmers Tekniska Hoegskola, Fundamental Fysik, Goeteborg (Sweden); CERN, PH Department, Geneve (Switzerland); Kanungo, R. [Saint Mary' s University, Astronomy and Physics Department, Halifax, NS (Canada); Nilsson, T.; Zhukov, M.V. [Chalmers Tekniska Hoegskola, Fundamental Fysik, Goeteborg (Sweden)

    2012-07-15

    One-neutron knockout reactions in a {sup 9}Be target have been investigated at relativistic energies, near 700 MeV/u, for a set of sd-shell, neutron-rich nuclei. The experiment was performed in the FRS spectrometer, at GSI. {gamma}-ray measurements were carried out by means of the MINIBALL {gamma}-ray spectrometer and allowed the determination of partial cross-sections and branching ratios corresponding to the final states of the emerging knockout fragments. Experimental results are presented for {sup 17}C, {sup 19}N, {sup 21}O and {sup 25}F projectiles. The role of excited states of the N - 1 fragments in the composition of the ground state of these neutron-rich projectiles is outlined in this work. (orig.)

  16. A neutron detector for measurement of total neutron production cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Kern, B.D.; Gabbard, F.

    1976-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p, n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p, n) 51 Cr and 57 Fe(p, n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given. (Auth.)

  17. The 2H(p,2p)n reaction at 508 MeV. Part I

    International Nuclear Information System (INIS)

    Punjabi, V.; Perdrisat, C.F.; Aniol, K.A.; Epstein, M.B.; Huber, J.P.; Margaziotis, D.J.; Bracco, A.; Davis, C.A.; Gubler, H.P.; Lee, W.P.; Poffenberger, P.R.; van Oers, W.T.H.; Postma, H.; Sebel, H.J.; Stetz, A.W.

    1988-09-01

    Differential cross sections for the reaction 2 H(p,2p)n at T p = 507 and 508 MeV are presented. The proton angle pairs chosen were 41.5 degrees with 41.4 and 50.0, 30.1 degrees with 44.0, 53,75, 61.0, and 68.0, 38.1 degrees -38.0 degrees, 44.1 degrees - 44.0 degrees, 47.1 degrees - 47.0 degrees and 50.0 degrees - 50.0 degrees. The data range over an energy window 100 MeV wide on one of the proton energies, the second energy being defined by the kinematic condition of a single neutron recoiling. The data are compared with the impulse approximation (IA) prediction and with the results of a nonrelativistic calculation of the six lowest-order Feynman diagrams describing the reaction. A previously known missing strength for the reaction in the small neutron recoil region is confirmed with much smaller experimental uncertainty; the missing strength persists up to 150 MeV/c neutron recoil. The onset of a systematic section excess relative to the IA near neutron recoil momentum 200 MeV is explored in detail. (Author) (37 refs., 17 figs.)

  18. Universal Fast Breeder Reactor Subassembly Counter manual

    International Nuclear Information System (INIS)

    Menlove, H.O.; Eccleston, G.W.; Swansen, J.E.; Goris, P.; Abedin-Zadeh, R.; Ramalho, A.

    1984-08-01

    A neutron coincidence counter has been designed for the measurement of fast breeder reactor fuel assemblies. This assay system can accommodate the full range of geometries and masses found in fast breeder subassemblies under IAEA safeguards. The system's high-performance capability accommodates high plutonium loadings of up to 16 kg. This manual describes the system and its operation and gives performance and calibration parameters for typical applications

  19. Development of quasi-monochromatic p-7Li neutron generating system for 80-210 MeV

    International Nuclear Information System (INIS)

    Nakao, Noriaki; Shibata, Tokushi; Nakamura, Takashi; Uwamino, Yoshitomo; Nakanishi, Noriyoshi; Kurosawa, Tadahiro; Kim, Unju.

    1996-01-01

    Recently the requirements for the experimental data on the response characteristics of neutron detector and the cross section for neutron generation by charged particles have been increasing for shield designing. Here, a system for quasi-monochromatic neutron generation was developed in the facility of ring-cyclotron in Institute of Physical and Chemical Sciences. In this study, H 2 + accelerated to an energy range of 80-135 MeV/n and P + to 150-210 MeV was irradiated to E4 beam course and NE102A plastic scintillator was used for monitoring the neutron flux. The amount of neutrons generated was estimated from the radioactivity of 7 Be produced in 7 Li-target. The neutron spectres thus estimated as an energy range of 80-210 MeV were presented and the lower limit of these spectres was about 20 MeV. The peaks in the range of 150 and 210 MeV were comparatively wide because of the inferiority of energy resolving power at a higher energy level. (M.N.)

  20. Research of accelerator-based neutron source for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Li Changkai; Ma Yingjie; Tang Xiaobin; Xie Qin; Geng Changran; Chen Da

    2013-01-01

    Background: 7 Li (p, n) reaction of high neutron yield and low threshold energy has become one of the most important neutron generating reactions for Accelerator-based Boron Neutron Capture Therapy (BNCT). Purpose Focuses on neutron yield and spectrum characteristics of this kind of neutron generating reaction which serves as an accelerator-based neutron source and moderates the high energy neutron beams to meet BNCT requirements. Methods: The yield and energy spectrum of neutrons generated by accelerator-based 7 Li(p, n) reaction with incident proton energy from 1.9 MeV to 3.0 MeV are researched using the Monte Carlo code-MCNPX2.5.0. And the energy and angular distribution of differential neutron yield by 2.5-MeV incident proton are also given in this part. In the following part, the character of epithermal neutron beam generated by 2.5-MeV incident protons is moderated by a new-designed moderator. Results: Energy spectra of neutrons generated by accelerator-based 7 Li(p, n) reaction with incident proton energy from 1.9 MeV to 3.0 MeV are got through the simulation and calculation. The best moderator thickness is got through comparison. Conclusions: Neutron beam produced by accelerator-based 7 Li(p, n) reaction, with the bombarding beam of 10 mA and the energy of 2.5 MeV, can meet the requirement of BNCT well after being moderated. (authors)

  1. The (x, T) magnetic phase diagram of Y2Co17-xCrx (1.17-bar x-bar 3) compounds by neutron diffraction

    International Nuclear Information System (INIS)

    Schobinger-Papamantellos, P.; Buschow, K.H.J.; Fuquan, B.; Tegus, O.; Brueck, E.; Boer, F.R. de; Ritter, C.

    2006-01-01

    We present the (x, T) phase diagram of the ferromagnetic Y 2 Co 17-x Cr x (x=1.17, 1.76, 2.34, 3) compounds with rhombohedral structure (space group R3-bar m, Th 2 Zn 17 -type), determined for the entire magnetically ordered regime from high-resolution neutron-diffraction data. Substitution of small amounts of Cr for Co was found to have drastic effects on the magnetic properties such as a decrease of the Curie (T C ) and spin reorientation (T SR ) temperatures as well as a decrease of the ordered-moment values. These effects could be brought into connection to the fact that Cr was found to have a preference for the four Co sites in the following order 6c>18f>9d>18h. The number of Cr atoms found occupying the latter two sites, however, is within experimental error negligible. The magnetic phase diagram comprises three distinct regions of magnetic order in addition to the paramagnetic state: (a) the HT range (easy axis) (b) the LT (easy plane) for 0 C and T SR . It also leads to the formation of varying portions of the hexagonal Th 2 Ni 17 -modification (with similar magnetic properties) in samples with x>=1.76. The crystal and magnetic structure of both modifications were refined simultaneously

  2. Spectroscopy of $^{46}$Ar by the $(t,p)$ two-neutron transfer reaction

    CERN Document Server

    Nowak, K.; Hellgartner, S.; Mücher, D.; Bildstein, V.; Diriken, J.; Elseviers, J.; Gaffney, L.P.; Gernhäuser, R.; Iwanicki, J.; Johansen, J.G.; Huyse, M.; Konki, J.; Kröll, T.; Krücken, T.; Lutter, R.; Orlandi, R.; Pakarinen, J.; Raabe, R.; Reiter, P.; Roger, T.; Schrieder, G.; Seidlitz, M.; Sorlin, O.; Van Duppen, P.; Warr, N.; De Witte, H.; Zielinska, M.

    2016-04-27

    States in the $N=28$ nucleus $^{46}$Ar have been studied by a two-neutron transfer reaction at REX-ISOLDE (CERN). A beam of radioactive $^{44}$ at an energy of 2.16~AMeV and a tritium loaded titanium target were used to populate $^{46}$ by the t($^{44}$,p) two-neutron transfer reaction. Protons emitted from the target were identified in the T-REX silicon detector array. The excitation energies of states in $^{46}$ have been reconstructed from the measured angles and energies of recoil protons. Angular distributions for three final states were measured and based on the shape of the differential cross section an excited state at 3695~keV has been identified as $J^\\pi = 0^+$. The angular differential cross section for the population of different states are compared to calculations using a reaction model employing both sequential and direct transfer of two neutrons. Results are compared to shell model calculations using state-of-the-art effective interactions.

  3. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  4. PROTEUS-SN User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Shemon, Emily R. [Argonne National Lab. (ANL), Argonne, IL (United States); Smith, Micheal A. [Argonne National Lab. (ANL), Argonne, IL (United States); Lee, Changho [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-02-16

    is a part of the SHARP multi-physics suite for coupled multi-physics analysis of nuclear reactors. This user manual describes how to set up a neutron transport simulation with the PROTEUS-SN code. A companion methodology manual describes the theory and algorithms within PROTEUS-SN.

  5. Description and performance characteristics for the neutron Coincidence Collar for the verification of reactor fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1981-08-01

    An active neutron interrogation method has been developed for the measurement of 235 U content in fresh fuel assemblies. The neutron Coincidence Collar uses neutron interrogation with an AmLi neutron source and coincidence counting the induced fission reaction neutrons from the 235 U. This manual describes the system components, operation, and performance characteristics. Applications of the Coincidence Collar to PWR and BWR types of reactor fuel assemblies are described

  6. Neutron scattering from [sup 12]C between 15. 6 and 17. 3 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z.M.; Baird, K.; Howell, C.R.; Roberts, M.L.; Tornow, W.; Walter, R.L. (Duke Univ., Durham, NC (United States). Dept. of Physics Triangle Universities Nuclear Lab., Durham, NC (United States))

    1993-06-01

    The differential cross section [sigma]([theta]) for neutron elastic scattering from [sup 12]C and for inelastic scattering from the 4.44 MeV state was measured at 15.57, 16.75 and 17.29 MeV. The [sigma]([theta]) data, together with published analysing power A[sub y]([theta]) data, were analysed in the framework of the spherical optical model and in the coupled-channels formalism. It was concluded that the present [sup 12]C(n,n)[sup 12]C data and published data at higher energies appear to be well suited for determining properties of valence single-particle excitations in [sup 11]C via an iterative-moment approach or a dispersive optical-model analysis. (author).

  7. A neutron detector for measurement of total neutron production cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Sekharan, K K; Laumer, H; Kern, B D; Gabbard, F [Kentucky Univ., Lexington (USA). Dept. of Physics and Astronomy

    1976-03-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight /sup 10/BF/sub 3/ counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from /sup 7/Li(p, n)/sup 7/Be. By adjusting the radial positions of the BF/sub 3/ counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from /sup 51/V(p, n)/sup 51/Cr and /sup 57/Fe(p, n)/sup 57/Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given.

  8. A search for solar neutron response in neutron monitor data

    International Nuclear Information System (INIS)

    Kudela, K.

    1990-01-01

    The search for an impulsive increase corresponding to a solar neutron response on high-mountain neutron monitors requires control of the stability of the measurement and elimination of other sources of short-time increases of different kinds which are involved in fluctuations of cosmic-ray intensity. For the solar flare of June 3, 1982 the excess of counting rate on the Lomnicky stit neutron monitor is, within a factor or 1.8, equal to that expected from solar neutrons. Superposed epoch analysis of 17 flares with gamma-ray or hard X-ray production gives a slight tendency of an occurring signal in cases of high heliocentric angles, indicating anisotropic production of neutrons on the sun. The low statistical significance of the result indicates that higher temporal resolution, better evaluation of multiplicity, better knowledge of the power spectra of short-term intensity fluctuations on neutron monitors, as well as coordinated measurements of solar gamma-rays and neutrons on satellites, are required. 21 refs

  9. Model calculation of neutron reaction data for {sup 31}P in the energy range from 0.1 to 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Jiangting, Li [Physics Department, Northwest Univ., Xi' an (China); Zhigang, Ge [China Nuclear Data Center, China Inst. of Atomic Energy, Beijing (China); Xiuquan, Sun [Engineering and Technology Department, Shenzhen University, Shenzhen (China)

    2006-07-15

    The neutron data calculation of {sup 31}P in the energy range from 0.1 to 20 MeV was carried out. The neutron optical potential parameters for {sup 31}P in energy range from O.1 to 20 MeV were obtained, based on the fitting of the available neutron experimental data with the code APOM94. The DWUCK4 code was used to investigate the cross section for neutron direct inelastic scattering. The re-evaluated neutron data is based on the available measured data by using the UNF code. The theoretical results reproduce the experimental data well, and the results were given in ENDF/B-6 format. (authors)

  10. Hair {sup 32}P measurement for body dose mapping in non-fatal exposures to fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mianji, Fereidoun A. [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Jafari, Sheyda; Zaryouni, Saiedeh [Bu-Ali Sina University, Faculty of Science, Hamedan (Iran, Islamic Republic of); Hajizadeh, Bardia [Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of)

    2015-03-15

    Dosimetry bioassay methods are the backbone of a personal dosimetry in criticality accidents. Although methods like hair dosimetry and the use of activation foils (e.g., {sup 32}S) have been employed for decades, capabilities of different techniques, effects of hair type and neutron spectrum on the dose response, sensitivity and uncertainties of different techniques, etc., need more investigations. For this reason, the use of the {sup 32}S(n,p){sup 32}P reaction and hair samples for estimating non-fatal doses from fast neutrons was studied. The experiments were carried out with the hair samples attached on a RANDO phantom in a Cf-252 neutron field, in the dose range of about 0.05-1.15 Gy. In addition, the adequate post-accident preparation for hair samples including optimum conditioning and timing were investigated. Experimental results prove the good sensitivity and merit of the method for neutron quantification in the mentioned dose range for which other bioassay methods are of poor resolution and sensitivity. A rough estimation of the dose-response curve for Iranian hair was also derived. (orig.)

  11. Clonal Ordering of 17p and 5q Allelic Losses in Barrett Dysplasia and Adenocarcinoma

    Science.gov (United States)

    Blount, Patricia L.; Meltzer, Stephen J.; Yin, Jing; Huang, Ying; Krasna, Mark J.; Reid, Brian J.

    1993-04-01

    Both 17p and 5q allelic losses appear to be involved in the pathogenesis or progression of many human solid tumors. In colon carcinogenesis, there is strong evidence that the targets of the 17p and 5q allelic losses are TP53, the gene encoding p53, and APC, respectively. It is widely accepted that 5q allelic losses precede 17p allelic losses in the progression to colonic carcinoma. The data, however, supporting this proposed order are largely based on the prevalence of 17p and 5q allelic losses in adenomas and unrelated adenocarcinomas from different patients. We investigated the order in which 17p and 5q allelic losses developed during neoplastic progression in Barrett esophagus by evaluating multiple aneuploid cell populations from the same patient. Using DNA content flow cytometric cell sorting and polymerase chain reaction, 38 aneuploid cell populations from 14 patients with Barrett esophagus who had high grade dysplasia, cancer or both were evaluated for 17p and 5q allelic losses. 17p allelic losses preceded 5q allelic losses in 7 patients, both 17p and 5q allelic losses were present in all aneuploid populations of 4 patients, and only 17p (without 5q) allelic losses were present in the aneuploid populations of 3 patients. In no patient did we find that a 5q allelic loss preceded a 17p allelic loss. Our data suggest that 17p allelic losses typically occur before 5q allelic losses during neoplastic progression in Barrett esophagus.

  12. Neutron Thermalization and Reactor Spectra. Vol. II. Proceedings of the Symposium on Neutron Thermalization and Reactor Spectra

    International Nuclear Information System (INIS)

    1968-01-01

    Proceedings of a Symposium organized by the IAEA and held at Ann Arbor, Michigan, USA, 17 - 21 July 1967. The meeting was attended by 143 participants from 24 Member States and one international organization. Contents: (Vol.I) Theory of neutron thermalization (15 papers); Scattering law (20 papers); Angular, space, temperature and time dependence of neutron spectra (9 papers). (Vol.II) Measurement of thermal neutron spectra and spectral indices, and comparison with theory (17 papers); Time-dependent problems in neutron thermalization (12 papers). Each paper is in its original language (61 English, 1 French and 11 Russian) and is preceded by an abstract in English with one in the original language if this is not English. Discussions are in English.

  13. Allelic imbalance and fine mapping of the 17p13.3 subregion in sporadic breast carcinomas

    DEFF Research Database (Denmark)

    Hoff, C; Mollenhauer, J; Waldau, B

    2001-01-01

    Chromosome arm 17p is frequently altered in a variety of human cancers, especially in breast cancer, and allelic imbalances (AIs) in the region 17p13.1 do not always coincide with mutations in the TP53 gene. A second interval that frequently shows AIs at 17p is the chromosomal band 17p13.3. This ......Chromosome arm 17p is frequently altered in a variety of human cancers, especially in breast cancer, and allelic imbalances (AIs) in the region 17p13.1 do not always coincide with mutations in the TP53 gene. A second interval that frequently shows AIs at 17p is the chromosomal band 17p13...

  14. Study of a neutron producing target via the 7Li(p,n)7Be reaction near its energy threshold for BNCT (boron neutron capture therapy)

    International Nuclear Information System (INIS)

    Burlon, Alejandro; Kreiner, Andres J.; Debray, Mario E.; Stoliar, Pablo; Kesque, Jose M.; Naab, Fabian; Ozafran, Mabel J.; Schuff, Juan; Vazquez, Monica; Caraballo, Maria E.; Valda, Alejandro; Somacal, Hector; Davidson, Miguel; Davidson, Jorge

    2000-01-01

    In the framework of Accelerator Based BNCT (AB-BNCT) the 7 Li(p,n) 7 Be reaction near its energy threshold is one of the most promising. In this work a thick LiF target irradiated with a proton beam was studied as a neutron source. The 1.88-2.0 MeV proton beam was produced by the tandem accelerator TANDAR at CNEA's facilities in Buenos Aires. A water-filled phantom, containing a boron sample was irradiated with the resulting neutron beam. The boron neutron capture reaction produces a 0.478 MeV gamma ray in 94 % of the cases. The neutron yield was monitored by detecting this gamma ray using a germanium detector with an 'anti-Compton' shield. Moreover, the thermal neutron flux was evaluated at different depths inside the phantom using bare and Cd-covered gold foils. A maximum neutron thermal flux of 1.4 x 10 8 1/(cm 2 -s-mA) was obtained at 4.2 cm from the phantom surface. (author)

  15. Study of 17O(p,α)14N reaction via the Trojan Horse Method for application to 17O nucleosynthesis

    International Nuclear Information System (INIS)

    Sergi, M. L.; Spitaleri, C.; Pizzone, R. G.; Gulino, M.; Cherubini, S.; Crucilla, V.; La Cognata, M.; Lamia, L.; Puglia, S. M. R.; Rapisarda, G. G.; Romano, S.; Tudisco, S.; Tumino, A.; Coc, A.; Burjan, V.; Hons, Z.; Kroha, V.; Hammache, F.; Sereville, N. de; Kiss, G.

    2008-01-01

    Because of the still present uncertainties on its rate, the 17 O(p,α) 14 N is one of the most important reaction to be studied in order to get more information about the fate of 17 O in different astrophysical scenarios. The preliminary study of the three-body reaction 2 H( 17 O,α 14 N)n is presented here as a first stage of the indirect study of this important 17 O(p,α) 14 N reaction through the Trojan Horse Method (THM)

  16. Universal Fast Breeder Reactor Subassembly Counter manual

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, H.O.; Eccleston, G.W.; Swansen, J.E.; Goris, P.; Abedin-Zadeh, R.; Ramalho, A.

    1984-08-01

    A neutron coincidence counter has been designed for the measurement of fast breeder reactor fuel assemblies. This assay system can accommodate the full range of geometries and masses found in fast breeder subassemblies under IAEA safeguards. The system's high-performance capability accommodates high plutonium loadings of up to 16 kg. This manual describes the system and its operation and gives performance and calibration parameters for typical applications.

  17. Neutron spectrometry with organic scintillation detector; Espectrometria de nuetrones con cristales de centelleo organicos

    Energy Technology Data Exchange (ETDEWEB)

    Butragueno Casdo, J L

    1972-07-01

    This work describes a fast neutron spectrometer using a stilbene crystal as head detector with pulse shape discrimination (P.S.D.) to reject gamma background. Tre experimental procedure involves the P.S.D., the measurements to calibrate the spectrometer and the corrections for several factors, mainly the non-linear response of the stilbene. Results of the measurements with the reaction D{sup 2}(d,n)He{sup 3}, and with an Am-Be neutron source are presented. It is also presented the measurement of the spectrum of the fast reactor CCRAl-1. (Author) 17 refs.

  18. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  19. MicroRNA-17-5p post-transcriptionally regulates p21 expression in irradiated betel quid chewing-related oral squamous cell carcinoma cells

    International Nuclear Information System (INIS)

    Wu, S.Y.; HungKuang Univ., Taichung; Lin, K.C.; Chiou, J.F.; Taipei Medical Univ. Hospital, Taipei; Taipei Medical Univ. Hospital, Taipei; Taipei Medical Univ. Hospital, Taipei; Jeng, S.C.; Cheng, W.H.; Chang, C.I.; Lin, W.C.; Wu, L.L.; Lee, H.L.; Chen, R.J.

    2013-01-01

    Background and purpose: Betel nut chewing is associated with oral cavity cancer in Taiwan. OC3 is an oral carcinoma cell line that was established from cells collected from a long-term betel nut chewer who does not smoke. After we found that microRNA-17-5p (miR-17-5p) is induced in OC3 cells, we used this cell line to examine the biological role(s) of this microRNA in response to exposure to ionizing radiation. Materials and methods: A combined SYBR green-based real-time PCR and oligonucleotide ligation assay was used to examine the expression of the miR-17 polycistron in irradiated OC3 cells. The roles of miR-17-5p and p21 were evaluated with specific antisense oligonucleotides (ODN) that were designed and used to inhibit their expression. Expression of the p21 protein was evaluated by Western blotting. The clonogenic assay and annexin V staining were used to evaluate cell survival and apoptosis, respectively. Cells in which miR-17-5p was stably knocked down were used to create ectopic xenografts to evaluate in vivo the role of miR-17-5p. Results: A radiation dose of 5 Gy significantly increased miR-17-5p expression in irradiated OC3 cells. Inhibition of miR-17-5p expression enhanced the radiosensitivity of the OC3 cells. We found that miR-17-5p downregulates radiation-induced p21 expression in OC3 cells and, by using a tumor xenograft model, it was found that p21 plays a critical role in increasing the radiosensitivity of OC3 cells in vitro and in vivo. Conclusion: miR-17-5p is induced in irradiated OC3 cells and it downregulates p21 protein expression, contributing to the radioresistance of OC3 cells. (orig.)

  20. MicroRNA-17-5p post-transcriptionally regulates p21 expression in irradiated betel quid chewing-related oral squamous cell carcinoma cells

    Energy Technology Data Exchange (ETDEWEB)

    Wu, S.Y. [Taipei Medical Univ., Wan Fang Hospital, Taipei (China). Dept. of Radiation-Oncology; HungKuang Univ., Taichung (China). Dept. of Biotechnology; Lin, K.C. [Taipei Medical Univ., Wan Fang Hospital, Taipei (China). Dept. of Oral and Maxillofacial Surgery; Chiou, J.F. [Taipei Medical Univ., Taipei (China). Dept. of Radiology; Taipei Medical Univ. Hospital, Taipei (China). Dept. of Radiation Oncology; Taipei Medical Univ. Hospital, Taipei (China). Dept. of Hospice and Palliative Center; Taipei Medical Univ. Hospital, Taipei (China). Cancer Center; Jeng, S.C. [Taipei Medical Univ. Hospital, Taipei (China). Dept. of Radiation Oncology; Cheng, W.H.; Chang, C.I. [Taipei Medical Univ., Wan Fang Hospital, Taipei (China). Dept. of Hemato-Ongology; Lin, W.C. [Taipei Medical Univ., Wan Fang Hospital, Taipei (China). Div. of Thoracic Surgery; Wu, L.L. [National Taiwan Univ. Hospital, Taipei (China). Dept. of Ophthalmology; Lee, H.L. [Taipei Medical Univ., Wan Fang Hospital, Taipei (China). Dept. of Radiation-Oncology; Chen, R.J. [National Taiwan Univ. Hospital and National Taiwan Univ., Taipei (China). Dept. of Obstetrics and Gynecology

    2013-08-15

    Background and purpose: Betel nut chewing is associated with oral cavity cancer in Taiwan. OC3 is an oral carcinoma cell line that was established from cells collected from a long-term betel nut chewer who does not smoke. After we found that microRNA-17-5p (miR-17-5p) is induced in OC3 cells, we used this cell line to examine the biological role(s) of this microRNA in response to exposure to ionizing radiation. Materials and methods: A combined SYBR green-based real-time PCR and oligonucleotide ligation assay was used to examine the expression of the miR-17 polycistron in irradiated OC3 cells. The roles of miR-17-5p and p21 were evaluated with specific antisense oligonucleotides (ODN) that were designed and used to inhibit their expression. Expression of the p21 protein was evaluated by Western blotting. The clonogenic assay and annexin V staining were used to evaluate cell survival and apoptosis, respectively. Cells in which miR-17-5p was stably knocked down were used to create ectopic xenografts to evaluate in vivo the role of miR-17-5p. Results: A radiation dose of 5 Gy significantly increased miR-17-5p expression in irradiated OC3 cells. Inhibition of miR-17-5p expression enhanced the radiosensitivity of the OC3 cells. We found that miR-17-5p downregulates radiation-induced p21 expression in OC3 cells and, by using a tumor xenograft model, it was found that p21 plays a critical role in increasing the radiosensitivity of OC3 cells in vitro and in vivo. Conclusion: miR-17-5p is induced in irradiated OC3 cells and it downregulates p21 protein expression, contributing to the radioresistance of OC3 cells. (orig.)

  1. De novo duplication of 17p13.1-p13.2 in a patient with intellectual disability and obesity.

    Science.gov (United States)

    Kuroda, Yukiko; Ohashi, Ikuko; Tominaga, Makiko; Saito, Toshiyuki; Nagai, Jun-Ichi; Ida, Kazumi; Naruto, Takuya; Masuno, Mitsuo; Kurosawa, Kenji

    2014-06-01

    17p13.1 Deletion encompassing TP53 has been described as a syndrome characterized by intellectual disability and dysmorphic features. Only one case with a 17p13.1 duplication encompassing TP53 has been reported in a patient with intellectual disability, seizures, obesity, and diabetes mellitus. Here, we present a patient with a 17p13.1 duplication who exhibited obesity and intellectual disability, similar to the previous report. The 9-year-old proposita was referred for the evaluation of intellectual disability and obesity. She also exhibited insulin resistance and liver dysfunction. She had wide palpebral fissures, upturned nostrils, a long mandible, short and slender fingers, and skin hyperpigmentation. Array comparative genomic hybridization (array CGH) detected a 3.2 Mb duplication of 17p13.1-p13.2 encompassing TP53, FXR2, NLGN2, and SLC2A4, which encodes the insulin-responsive glucose transporter 4 (GLUT4) associated with insulin-stimulated glucose uptake in adipocytes and muscle. We suggest that 17p13.1 duplication may represent a clinically recognizable condition characterized partially by a characteristic facial phenotype, developmental delay, and obesity. © 2014 Wiley Periodicals, Inc.

  2. Effectiveness of Manual Therapy and Stretching for Baseball Players With Shoulder Range of Motion Deficits.

    Science.gov (United States)

    Bailey, Lane B; Thigpen, Charles A; Hawkins, Richard J; Beattie, Paul F; Shanley, Ellen

    Baseball players displaying deficits in shoulder range of motion (ROM) are at increased risk of arm injury. Currently, there is a lack of consensus regarding the best available treatment options to restore shoulder ROM. Instrumented manual therapy with self-stretching will result in clinically significant deficit reductions when compared with self-stretching alone. Controlled laboratory study. Shoulder ROM and humeral torsion were assessed in 60 active baseball players (mean age, 19 ± 2 years) with ROM deficits (nondominant - dominant, ≥15°). Athletes were randomly assigned to receive a single treatment of instrumented manual therapy plus self-stretching (n = 30) or self-stretching only (n = 30). Deficits in internal rotation, horizontal adduction, and total arc of motion were compared between groups immediately before and after a single treatment session. Treatment effectiveness was determined by mean comparison data, and a number-needed-to-treat (NNT) analysis was used for assessing the presence of ROM risk factors. Prior to intervention, players displayed significant ( P < 0.001) dominant-sided deficits in internal rotation (-26°), total arc of motion (-18°), and horizontal adduction (-17°). After the intervention, both groups displayed significant improvements in ROM, with the instrumented manual therapy plus self-stretching group displaying greater increases in internal rotation (+5°, P = 0.010), total arc of motion (+6°, P = 0.010), and horizontal adduction (+7°, P = 0.004) compared with self-stretching alone. For horizontal adduction deficits, the added use of instrumented manual therapy with self-stretching decreased the NNT to 2.2 (95% CI, 2.1-2.4; P = 0.010). Instrumented manual therapy with self-stretching significantly reduces ROM risk factors in baseball players with motion deficits when compared with stretching alone. The added benefits of manual therapy may help to reduce ROM deficits in clinical scenarios where stretching alone is

  3. Kinetic energy spectrum and polarization of neutrons from the reaction 12C(p,n)X at 590 MeV

    International Nuclear Information System (INIS)

    Arnold, J.

    1998-01-01

    The kinetic energy spectrum and the polarization of the PSI neutron beam produced in the reaction 12 C(p,n)X at 0 with 590 MeV polarized protons were investigated. A strong energy dependence of the neutron beam polarization is observed which was not expected at the time the neutron beam was built. (orig.)

  4. File list: InP.Bld.50.AllAg.Th17 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Bld.50.AllAg.Th17 mm9 Input control Blood Th17 SRX288138,SRX495621,SRX288137,SR...X220933,SRX172342,SRX1328057,SRX1328056 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Bld.50.AllAg.Th17.bed ...

  5. Cytochrome P450c17 (steroid 17α-hydroxylase/17,20 lyase): cloning of human adrenal and testis cDNAs indicates the same gene is expressed in both tissues

    International Nuclear Information System (INIS)

    Chung, B.; Picado-Leonard, J.; Haniu, M.; Bienkowski, M.; Hall, P.F.; Shively, J.E.; Miller, W.L.

    1987-01-01

    P450c17 is the single enzyme mediating both 17α-hydroxylase (steroid 17α-monooxygenase, EC 1.14.99.9) and 17,20 lyase activities in the synthesis of steroid hormones. It has been suggested that different P450c17 isozymes mediate these activities in the adrenal gland and testis. The authors sequenced 423 of the 509 amino acids (83%) of the porcine adrenal enzyme; based on this partial sequence, a 128-fold degenerate 17-mer was synthesized and used to screen a porcine adrenal cDNA library. This yielded a 380-base cloned cDNA, which in turn was used to isolate several human adrenal cDNAs. The longest of these, λ hac 17-2, is 1754 base pairs long and includes the full-length coding region, the complete 3'-untranslated region, and 41 bases of the 5'-untranslated region. This cDNA encodes a protein of 508 amino acids having a predicted molecular weight of 57,379.82. High-stringency screening of a human testicular cDNA library yielded a partial clone containing 1303 identical bases. RNA gel blots and nuclease S1-protection experiments confirm that the adrenal and testicular P450c17 mRNAs are indistinguishable. These data indicate that the testis possesses a P450c17 identical to that in the adrenal. The human amino acid sequence is 66.7% homologous to the corresponding regions of the porcine sequence, and the human cDNA and amino acid sequences are 80.1 and 70.3% homologous, respectively, to bovine adrenal P450c17 cDNA. Both comparisons indicate that a central region comprising amino acid residues 160-268 is hypervariable among these species of P450c17

  6. Experimental study on p-wave neutron strength functions for light nuclei

    International Nuclear Information System (INIS)

    Koester, L.; Waschkowski, W.; Meier, J.; Rau, G.; Salehi, M.

    1988-01-01

    Broad energy distributions in fast neutron beams have been achieved by appropriate filtering of the 236 U fission radiation provided from the RENT converter facility at the FRM research reactor. Transmission measurements in such beams result in average cross sections to which resonance reactions and shape elastic scattering contribute. We used a silicon (124.5 cm) filtered beam with a median energy of 143 keV (width 20 keV) and beams with 1.3 MeV (0.55 to 3 MeV) and 2.1 MeV (1 to 5.5 MeV) obtained through different filter combinations of lead and polyethylene. The relative high energies and the broad spectra made it possible to determine experimentally the contributions of s- and p-wave resonance reactions to the average cross section even for light nuclei. Using the three different beams we determined the average cross sections for the elements in the mass region A = 9 to 65. Analysing the measured cross sections by means of the R matrix formalism provided a complete set of p-wave strength functions and distant level parameters. Moreover, single particle shell effects in the cross sections were observed. In conclusion we obtained information on the 2P and the 3S size resonances and about the validity of the optical model for neutron reactions with light nuclei. (orig.)

  7. Calibration of detector efficiency of neutron detector

    International Nuclear Information System (INIS)

    Guo Hongsheng; He Xijun; Xu Rongkun; Peng Taiping

    2001-01-01

    BF 3 neutron detector has been set up. Detector efficiency is calibrated by associated particle technique. It is about 3.17 x 10 -4 (1 +- 18%). Neutron yield of neutron generator per pulse (10 7 /pulse) is measured by using the detector

  8. Spectral flux of the p-7Li(C Q-M neutron source measured by proton recoil telescope

    Directory of Open Access Journals (Sweden)

    Simakov S.P.

    2010-10-01

    Full Text Available The cyclotron-based fast neutron source at NPI produces mono-energetic neutron fields up to 35 MeV neutron energy using the p + 7Li(carbon backing reactions. To be applied for activation cross-section measurements, not only the intensity of neutron peak, but also the contribution of low-energy continuum in the spectra must be well determined. Simulations of the spectral flux from present source at a position of irradiated samples were performed using CYRIC TOF-data validated in the present work against LA150h by calculations with the transport Monte Carlo code MCNPX. Simulated spectra were tested by absolute measurements using a proton-recoil telescope technique. The recoil-proton spectrometer consisted of a shielded scattering chamber with polyethylene and carbon radiators and the ΔE1-ΔE2-E telescope of silicon-surface detectors located to the neutron beam axis at 45° in the laboratory system. Si-detectors were handled by usual data acquisition system. Dead-time – and pulse-overlap losses of events were determined from the count rate of pulse generator registered during duty cycle of accelerator operation. The proton beam charge and data were taken in the list mode for later replay and analysis. The calculations for 7Li(p,n and 12C(p,n reactions reasonably reproduce CYRIC TOF neutron source spectra. The influence of neutron source set-up (proton beam dimensions, 7Li-foil, carbon stopper, cooling medium, target support/chamber and the geometry-arrangement of irradiated sample on the spectral flux is discussed in details.

  9. Average number of neutrons in π-p, π-n, and π-12C interactions at 4 GeV/c

    International Nuclear Information System (INIS)

    Bekmirzaev, R.N.; Grishin, V.G.; Muminov, M.M.; Suvanov, I.; Trka, Z.; Trkova, J.

    1984-01-01

    The average numbers of secondary neutrons in π - p, π - n, and π -12 C interactions at 4 GeV/c have been determined by investigating secondary neutral stars produced by neutrons in a propane bubble chamber. The following values were obtained for the charge-exchange coefficients: α(p→n) = 0.39 +- 0.04 and α(n→p) = 0.37 +- 0.08

  10. Use of the n,p scattering reaction for neutron flux measurements

    International Nuclear Information System (INIS)

    Czirr, J.B.

    1977-01-01

    Several contemporary proton-recoil detectors are described and compared. These detectors have been used for neutron-spectrum measurements over various portions of the 10-keV-to-20-MeV energy range. Several factors which limit the accuracy of the results are compared quantitatively. General suggestions are given for setting and using standard cross sections and for future developments using the n,p scattering reaction

  11. Study of the response of a piezoceramic motor irradiated in a fast reactor up to a neutron fluence of 2.77E+17 n/cm2

    International Nuclear Information System (INIS)

    Pillon, Mario; Monti, Chiara; Mugnaini, Giampiero; Neri, Carlo; Rossi, Paolo; Carta, Mario; Fiorani, Orlando; Santagata, Alfonso

    2015-01-01

    Highlights: • Piezoceramic motors are compliant with magnetic field, temperature and vacuum. • We studied the response of a piezoceramic motor during the irradiation with neutrons. • The response was studied using 1 MeV neutrons up to a neutron fluence of 2.77E+17 n/cm 2 . • Neutron irradiation produces a shift of the optimal resonance frequency and a decrease of the motor speed. • The performance changes do not affect the proper operation of the motor. - Abstract: A piezoceramic motor has been identified as the potential apparatus for carrying out the rotation of the scanning head of a laser radar system used for viewing the first wall of the ITER vessel. This diagnostic is simply referred to as IVVS (In Vessel Viewing System). The choice fell on a piezoceramic motor due to the presence of strong magnetic fields (up 8 T) and of the high vacuum and temperature conditions. To be compliant with all the ITER environmental conditions it was necessary to qualify the piezo-motor under gamma and neutron irradiation. In this paper are described the procedures and tests that have been performed to verify the compatibility of the operation of the motor adopted in the presence of a fast neutron fluence which was gradually increased over time in order to reach a total value of 2.77 × 10 17 n/cm 2 . Such neutron fluence was obtained by irradiating the motor in a position close to the core of the fast nuclear reactor TAPIRO, in operation at the ENEA Casaccia Research Centre, Italy. The neutron spectrum in this position has been identified as representative of that found in the rest position of the IVVS head during ITER operation. The cumulative neutron fluence reached corresponds to that it is expected to be reached during the entire life of ITER for the IVVS in the rest position without any shield. This work describes the experimental results of this test; the methodology adopted to determine the total neutron fluence achieved and the methodology adopted for the

  12. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  13. 75 years ago. The discovery of nuclear fission during the neutron irradiation of uranium on 17 December 1938 in Berlin

    International Nuclear Information System (INIS)

    Kuczera, Bernhard

    2013-01-01

    A ground-breaking, scientific discovery made in the Berlin experiments of the year 1938 on neutron irradiation of uranium, was that atom nuclei can be fissured and, during the fission energy, so-called nuclear energy, is released. If further U-235 atoms are in the immediate vicinity, the released neutrons can trigger a chain reaction of the nuclear fission. The story of this ground-breaking discovery that led to the worldwide civil utilisation of nuclear energy is outlined here. The discovery of neutrons and their implementation in radiation experiments occurred in the 1930s. The research work followed the model of the Stockholm citizen Niels Bohr on the configuration of an atom. In 1930, Walther Bothe reported on the occurrence of a high-energy radiation when beryllium was irradiated with alpha-particles. James Chadwick could prove experimentally in 1932 that this is a current of high-energy, electrically neutral particles. He called these particles neutrons. In Berlin, the radio-chemist Otto Hahn is the Director at the Kaiser-Wilhelm-Institute for Chemistry and head of the chemical-radioactive department. In the years 1935 to 1938, the radiation experiments of uranium with neutrons were at the centre of the research in Berlin. In October 1938, Hahn and Strassmann responded with their own experiments to the scientific challenge of Irene Curie and Paul Savitch of 3.5-hours of activity when uranium was radiated with neutrons. The decisive discovery for the neutron radiation of uranium was made by Hahn and Strassmann on 17 December 1938. From the results of different experiments, they conclude: 'Our radium isotopes have the properties of barium.' On 19 December, Hahn informs Lise Meitner and speaking on the issue of 'Where does the barium come from?' addresses a possible 'bursting' of the uranium nucleus. That is Hahn's 'Heureka.' moment: He recognises that the neutron radiation does not only effect radiochemical transformations, but can also cause the uranium

  14. Production of 14 MeV neutrons from D-D neutron generators

    International Nuclear Information System (INIS)

    Cecil, F.E.; Nieschmidt, E.B.

    1986-01-01

    The production of 14 MeV neutrons from a D-D neutron generator resulting from tritium buildup from the d(d,p)t reaction in the target is discussed. The effect of the 14 MeV neutrons on fast neutron activation analysis with D-D neutron generators is evaluated. (orig.)

  15. The activation method for determining neutron spectra and fluences

    International Nuclear Information System (INIS)

    Hogel, J.; Vespalec, R.

    1980-01-01

    3 mm thick foils of 4 and 17 mm in diameter were used for measurements. NaI scintillation detectors 45 mm in diameter by 50 mm thick and 40 mm in diameter by 1 mm thick, and a Ge-Li spectrometer of 53 cm 3 in volume were used for gamma detection. A photopeak or a certain part of the integral spectrum was measured for each radionuclide. Computer code PIKAR was applied in automatic calculation of a simple gamma spectrum obtained using the semiconductor spectrometer. The FACT code was used for calculating foil activity. Codes SAND II and RFSP were used for neutron spectra unfolding. Ge-Li detector spectrometry was used for determining neutron fluence. Code FLUE was used for determining the mean value of neutron flux density and fluence. (J.P.)

  16. Extraction of neutron-neutron scattering length from nn coincidence-geometry nd breakup data

    Directory of Open Access Journals (Sweden)

    E. S. Konobeevski

    2011-03-01

    Full Text Available We report preliminary results of a kinematically complete experiment on measurement of nd breakup reaction yield at neutron beam RADEX of Institute for Nuclear Research (Moscow, Russia. In the experiment two secondary neutrons are detected in geometry of neutron-neutron final-state interaction. Data are obtained at energy of incident neutrons En = 40 - 60 MeV for various divergence angles of two neutrons ΔΘ = 4, 6, 8º. 1S0 neutron-neutron scattering length ann were determined by comparison of the experimental dependence of reaction yield on the relative energy of two secondary neutrons with results of simulation depending on ann. For En = 40 MeV and ΔΘ = 6º (the highest statistics in the experiment the value ann = -17.9 ± 1.0 fm is obtained. The further improving of accuracy of the experiment and more rigorous theoretical analysis will allow one to remove the existing difference in ann values obtained in different experiments.

  17. Construction of monoenergetic neutron calibration fields using 45Sc(p, n)45Ti reaction at JAEA.

    Science.gov (United States)

    Tanimura, Y; Saegusa, J; Shikaze, Y; Tsutsumi, M; Shimizu, S; Yoshizawa, M

    2007-01-01

    The 8 and 27 keV monoenergetic neutron calibration fields have been developed by using (45)Sc(p, n)(45)Ti reaction. Protons from a 4-MV Pelletron accelerator are used to bombard a thin scandium target evaporated onto a platinum disc. The proton energies are finely adjusted to the resonance to generate the 8 and 27 keV neutrons by applying a high voltage to the target assemblies. The neutron energies were measured using the time-of-flight method with a lithium glass scintillation detector. The neutron fluences at a calibration point located at 50 cm from the target were evaluated using Bonner spheres. A long counter was placed at 2.2 m from the target and at 60 degrees to the direction of the proton beam in order to monitor the fluence at the calibration point. Fluence and dose equivalent rates at the calibration point are sufficient to calibrate many types of the neutron survey metres.

  18. Neutron capture prompt gamma-ray activation analysis at the NIST cold neutron research facility

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, R M; Zeisler, R; Vincent, D H; Greenberg, R R; Stone, C A; Mackey, E A [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Anderson, D L [Food and Drug Administration, Washington, DC (United States); Clark, D D [Cornell Univ., Ithaca, NY (United States)

    1993-01-01

    An instrument for neutron capture prompt gamma-ray activation analysis (PGAA) has been constructed as part of the Cold Neutron Research Facility at the 20 MW National Institute of Standards and Technology Research Reactor. The neutron fluence rate (thermal equivalent) is 1.5*10[sup 8] n*cm[sup -2]*s[sup -] [sup 1], with negligible fast neutrons and gamma-rays. With compact geometry and hydrogen-free construction, the sensitivity is sevenfold better than an existing thermal instrument. Hydrogen background is thirtyfold lower. (author) 17 refs.; 2 figs.

  19. Study of the 17O(n,α)14C reaction: Extension of the Trojan Horse Method to neutron induced reactions

    International Nuclear Information System (INIS)

    Guardo, G. L.; Lamia, L.; Spitaleri, C.; Cherubini, S.; Rapisarda, G. G.; Sergi, M. L.; Gulino, M.; Tang, X. D.; Bucher, B.; Couder, M.; Davies, P.; Boer, R. de; Fang, X.; Lamm, L.; Ma, C.; Notani, M.; OBrien, S.; Roberson, D.; Tan, W.; Wiescher, M.

    2014-01-01

    The experimental study of the 17 O(n,α) 14 C reaction has been performed in the energy range 0-350 keV. This reaction could play an important role in explaining heavy elements (s-process) nucleosynthesis in various astrophysical scenario. To overcome the practical problems arising from the neutrons production, a new application of the Trojan Horse Method has been recently suggested. In more details, the 17 O(n,α) 14 C reaction has been studied using the quasi-free 2 H( 17 O,α 14 C) 1 H reaction, induced at an energy of 43.5 MeV. The measurement allows one to investigate the ℓ=3, 75 keV resonance (E*=8.125 MeV, J π =5 − ), absent in the available direct measurements because of centrifugal suppression effects

  20. Application of neutron activation analysis to control P2O5 content in ore and ore concentrates of ''Apatit'' works

    International Nuclear Information System (INIS)

    Belyakov, M.A.; Terent'eV, Eh.P.; Frolov, V.A.

    1982-01-01

    A technique for a neutron activation rapid analysis of fluorine is described. A mean-square error of the analysis makes up 0,g3 per cent F. The investigation has been carried out and a close correlation has been established for the Hibine massif exploited apatite deposits on the basis of the neutron activation analysis of fluorine and chemical analysis of P 2 O 5 . Possibilities are shown of using the neutron activation analysis of P 2 O 5 in ores and certain ore con-- centrates of ''Apatit'' works from the radioactivity induced in fluorine. A mean-square error of the analysis makes up 0,35 per cent P 2 O 5

  1. Determination of Al, Si and P in certified reference materials by Instrumental Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Noyori, Amanda; Saiki, Mitiko, E-mail: anoyori@gmail.com, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Neutron analysis activation is not commonly used for aluminum, phosphorus and silicon determination, due to the difficulty to obtain reliable results. In this study, Al was determined by measuring {sup 28}Al and the contribution of P and Si due to {sup 28}Al formed in {sup 31}P(n,α){sup 28}Al and {sup 28}Si(n,p){sup 28}Al reactions were corrected using correction factors determined experimentally. Phosphorus was determined by measuring {sup 32}P (pure beta emitter) formed in reaction {sup 31}P(n,γ){sup 32}P. Silicon was determined by epithermal neutron analysis activation (ENAA) and measuring {sup 29}Al radionuclide formed in {sup 29}Si(n,p){sup 29}Al reaction. Aliquots of certified reference materials (CRMs) and synthetic standards of the elements were irradiated together, using the pneumatic transfer station of IEA-R1 nuclear research reactor. Results obtained for biological and geological CRMs showed good precision and accuracy with |Z-score| < 2 for Al, P and Si determinations. The detection limits for Al, P and Si determinations CRMs were also evaluated. Results obtained in this study demonstrated the viability of applying INAA procedures in the determination of Al, P and Si. (author)

  2. Determination of Al, Si and P in certified reference materials by Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Noyori, Amanda; Saiki, Mitiko

    2017-01-01

    Neutron analysis activation is not commonly used for aluminum, phosphorus and silicon determination, due to the difficulty to obtain reliable results. In this study, Al was determined by measuring "2"8Al and the contribution of P and Si due to "2"8Al formed in "3"1P(n,α)"2"8Al and "2"8Si(n,p)"2"8Al reactions were corrected using correction factors determined experimentally. Phosphorus was determined by measuring "3"2P (pure beta emitter) formed in reaction "3"1P(n,γ)"3"2P. Silicon was determined by epithermal neutron analysis activation (ENAA) and measuring "2"9Al radionuclide formed in "2"9Si(n,p)"2"9Al reaction. Aliquots of certified reference materials (CRMs) and synthetic standards of the elements were irradiated together, using the pneumatic transfer station of IEA-R1 nuclear research reactor. Results obtained for biological and geological CRMs showed good precision and accuracy with |Z-score| < 2 for Al, P and Si determinations. The detection limits for Al, P and Si determinations CRMs were also evaluated. Results obtained in this study demonstrated the viability of applying INAA procedures in the determination of Al, P and Si. (author)

  3. Non-structural proteins P17 and P33 are involved in the assembly of the internal membrane-containing virus PRD1

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, Jenni; Mäntynen, Sari [Centre of Excellence in Biological Interactions, Department of Biological and Environmental Science and Nanoscience Center, University of Jyväskylä, P.O. Box 35, 40014 Jyväskylä (Finland); Ihalainen, Teemu O. [Stem Cells in Neurological Applications Group, BioMediTech, University of Tampere, Tampere (Finland); Bamford, Jaana K.H. [Centre of Excellence in Biological Interactions, Department of Biological and Environmental Science and Nanoscience Center, University of Jyväskylä, P.O. Box 35, 40014 Jyväskylä (Finland); Oksanen, Hanna M., E-mail: hanna.oksanen@helsinki.fi [Institute of Biotechnology and Department of Biosciences, University of Helsinki, Biocenter 2, P.O. Box 56 (Viikinkaari 5), FIN-00014 Helsinki (Finland)

    2015-08-15

    Bacteriophage PRD1, which has been studied intensively at the structural and functional levels, still has some gene products with unknown functions and certain aspects of the PRD1 assembly process have remained unsolved. In this study, we demonstrate that the phage-encoded non-structural proteins P17 and P33, either individually or together, complement the defect in a temperature-sensitive GroES mutant of Escherichia coli for host growth and PRD1 propagation. Confocal microscopy of fluorescent fusion proteins revealed co-localisation between P33 and P17 as well as between P33 and the host chaperonin GroEL. A fluorescence recovery after photobleaching assay demonstrated that the diffusion of the P33 fluorescent fusion protein was substantially slower in E. coli than theoretically calculated, presumably resulting from intermolecular interactions. Our results indicate that P33 and P17 function in procapsid assembly, possibly in association with the host chaperonin complex GroEL/GroES. - Highlights: • Two non-structural proteins of PRD1 are involved in the virus assembly. • P17 and P33 complement the defect in GroES of Escherichia coli. • P33 co-localises with GroEL and P17 in the bacterium. • Slow motion of P33 in the bacterium suggests association with cellular components.

  4. A Course on Operational Considerations in Wastewater Treatment Plant Design. Instructor's Manual.

    Science.gov (United States)

    Cooper, John W.; And Others

    This manual contains 17 instructional units (sequenced to correspond to parallel chapters in a student's manual) focusing on upgrading the design of wastewater plant facilities and serving as a reference source for establishing criteria for upgrading wastewater treatment plants. The manual also furnishes information for modifying plant design to…

  5. HRTEM and neutron diffraction study of LixMo5O17: From the ribbon (x=5) structure to the rock salt (x=12) structure

    International Nuclear Information System (INIS)

    Lebedev, O.I.; Caignaert, V.; Raveau, B.; Pop, N.; Gozzo, F.; Van Tendeloo, G.; Pralong, V.

    2011-01-01

    Structure determination of the fully intercalated phase Li 12 Mo 5 O 17 and of the deintercalated oxide Li 5 Mo 5 O 17 has been carried out by electron microscopy and neutron powder diffraction. The reversible topotactic transformation between the ordered rock salt structure of the former and the ribbon structure of the latter (closely related to that of Li 4 Mo 5 O 17 ) is explained on the following basis: both structures can be described as strips built up as an assembly of infinite ribbons of MoO 6 octahedra that are five octahedra thick, and that differ by slight displacements of the octahedral ribbons. We show that the electrochemical behavior of the Li x Mo 5 O 17 system is based on two sorts of Li + sites; those that are located within the strips between the ribbons, and those that are located at the border of the strips. The high rate of Li intercalation in this oxide and its reversibility are discussed in terms of its peculiar structure. -- Graphical abstract: Structure determination of the fully intercalated phase Li 12 Mo 5 O 17 and of the deintercalated oxide Li 5 Mo 5 O 17 has been carried out by electron microscopy and neutron powder diffraction. The reversible topotactic transformation between the ordered rock salt structure of the former and the ribbon structure of the latter is explained on the following basis: both structures can be described as strips built up as an assembly of infinite ribbons of MoO 6 octahedra that are five octahedra thick, and that differ by slight displacements of the octahedral ribbons. We show that the electrochemical behavior of the Li x Mo 5 O 17 system is based on two sorts of Li + sites; those that are located within the strips between the ribbons, and those that are located at the border of the strips. The high rate of Li intercalation in this oxide and its reversibility are discussed in terms of its peculiar structure. Research highlights: → Electron microscopy and neutron powder diffraction structure determination

  6. Gadolinium heteropoly complex K 17[Gd(P 2W 17O 61) 2] as a potential MRI contrast agent

    Science.gov (United States)

    Sun, Guoying; Feng, Jianghua; Wu, Huifeng; Pei, Fengkui; Fang, Ke; Lei, Hao

    2004-10-01

    Gadolinium heteropoly complex K17[Gd(P2W17O61)2] has been evaluated by in vitro and in vivo experiments as a potential contrast agent for magnetic resonance imaging (MRI). The thermal analysis and conductivity study indicate that this complex has good thermal stability and wide pH stability range. The T1 relaxivity is 7.59 mM-1 s-1 in aqueous solution and 7.97 mM-1 s-1 in 0.725 mmol l-1 bovine serum albumin (BSA) solution at 25 °C and 9.39 T, respectively. MR imaging of three male Sprague-Dawley rats showed remarkable enhancement in rat liver after intravenous injection, which persisted longer than with Gd-DTPA. The signal intensity increased by 57.1±16.9% during the whole imaging period at 0.082 mmol kg-1dose. Our preliminary in vitro and in vivo studies indicate that K17[Gd(P2W17O61)2] is a potential liver-specific MRI contrast agent.

  7. Study of the response of a piezoceramic motor irradiated in a fast reactor up to a neutron fluence of 2.77E+17 n/cm{sup 2}

    Energy Technology Data Exchange (ETDEWEB)

    Pillon, Mario, E-mail: mario.pillon@enea.it [Associazione EURATOM-ENEA sulla Fusione, ENEA C.R. Frascati, via E. Fermi, 45, 00044 Frascati, Rome (Italy); Monti, Chiara; Mugnaini, Giampiero; Neri, Carlo; Rossi, Paolo [Associazione EURATOM-ENEA sulla Fusione, ENEA C.R. Frascati, via E. Fermi, 45, 00044 Frascati, Rome (Italy); Carta, Mario; Fiorani, Orlando; Santagata, Alfonso [ENEA C.R. CASACCIA, via Anguillarese, 301, 00123 S. Maria di Galeria, Rome (Italy)

    2015-10-15

    Highlights: • Piezoceramic motors are compliant with magnetic field, temperature and vacuum. • We studied the response of a piezoceramic motor during the irradiation with neutrons. • The response was studied using 1 MeV neutrons up to a neutron fluence of 2.77E+17 n/cm{sup 2}. • Neutron irradiation produces a shift of the optimal resonance frequency and a decrease of the motor speed. • The performance changes do not affect the proper operation of the motor. - Abstract: A piezoceramic motor has been identified as the potential apparatus for carrying out the rotation of the scanning head of a laser radar system used for viewing the first wall of the ITER vessel. This diagnostic is simply referred to as IVVS (In Vessel Viewing System). The choice fell on a piezoceramic motor due to the presence of strong magnetic fields (up 8 T) and of the high vacuum and temperature conditions. To be compliant with all the ITER environmental conditions it was necessary to qualify the piezo-motor under gamma and neutron irradiation. In this paper are described the procedures and tests that have been performed to verify the compatibility of the operation of the motor adopted in the presence of a fast neutron fluence which was gradually increased over time in order to reach a total value of 2.77 × 10{sup 17} n/cm{sup 2}. Such neutron fluence was obtained by irradiating the motor in a position close to the core of the fast nuclear reactor TAPIRO, in operation at the ENEA Casaccia Research Centre, Italy. The neutron spectrum in this position has been identified as representative of that found in the rest position of the IVVS head during ITER operation. The cumulative neutron fluence reached corresponds to that it is expected to be reached during the entire life of ITER for the IVVS in the rest position without any shield. This work describes the experimental results of this test; the methodology adopted to determine the total neutron fluence achieved and the methodology adopted

  8. User's manual for the reactor burnup system, REBUS

    International Nuclear Information System (INIS)

    Olson, A.P.; Regis, J.P.; Meneley, D.A.; Hoover, L.J.

    1972-01-01

    A user's manual for the REBUS System (REactor BUrnup System) is presented. Its primary purpose is to provide sufficient information about the REBUS capability to the user to ensure its efficient utilization. The current REBUS System either solves for the infinite time (equilibrium) operating conditions of a recycle system under fixed conditions, or solves for operating conditions during a single time step (non-equilibrium). The capability of studying various in-reactor fuel management and ex-reactor fuel management schemes has been included. REBUS has been operated with one- and two-dimensional diffusion theory neutronics solutions up to the present time. The model was specifically designed for extension to other neutronics models such as three-dimensional diffusion or transport theory and direct or synthesis solutions

  9. Measurement of cross sections for the scattering of neutrons in the energy range from 2 MeV to 4 MeV with the 15N(p,n) reaction as neutron source

    International Nuclear Information System (INIS)

    Poenitz, Erik

    2010-01-01

    In future nuclear facilities, the materials lead and bismuth can play a more important role than in today's nuclear reactors. Reliable cross section data are required for the design of those facilities. In particular the neutron transport in the lead spallation target of an Accelerator-Driven Subcritical Reactor strongly depends on the inelastic neutron scattering cross sections in the energy region from 0.5 MeV to 6 MeV. In the recent 20 years, elastic and inelastic neutron scattering cross sections were measured with high precision for a variety of elements at the PTB time-of-flight spectrometer. The D(d,n) reaction was primarily used for the production of neutrons. Because of the Q value of the reaction and the available deuteron energies, neutrons in the energy range from 6 MeV to 16 MeV can be produced. For the cross section measurement at lower energies, however, another neutron producing reaction is required. The 15 N(p,n) 15 O reaction was chosen, as it allows the production of monoenergetic neutrons with up to 5.7MeV energy. In this work, the 15 N(p,n) reaction was studied with focus on the suitability as a source for monoenergetic neutrons in scattering experiments. This includes the measurement of differential cross sections for the neutron producing reaction and the choice of optimum target conditions. Differential elastic and inelastic neutron scattering cross sections were measured for lead at four energies in the region from 2 MeV to 4 MeV incident neutron energy using the time-of-flight technique. A lead sample with natural isotopic composition was used. NE213 liquid scintillation detectors with well-known detection efficiencies were used for the detection of the scattered neutrons. Angle-integrated cross sections were determined by a Legendre polynomial expansion using least-squares methods. Additionally, measurements were carried out for isotopically pure 209 Bi and 181 Ta samples at 4 MeV incident neutron energy. Results are compared with other

  10. AFM-CMM integrated instrument user manual

    DEFF Research Database (Denmark)

    Marinello, Francesco; Bariani, Paolo

    This manual gives general important guidelines for a proper use of the integrated AFM-CMM instrument. More information can be collected reading: • N. Kofod Ph.D thesis [1]; • P. Bariani Ph.D thesis [2]; • Dualscope DME 95-200 operation manuals [3]; • SPIP help [4] • Stitching software user manual...

  11. The magnetic form factor of the neutron, GMn, from the d(e,e'n)p reaction

    International Nuclear Information System (INIS)

    Markowitz, P.E.C.

    1992-01-01

    The author measured the d(e,e'n)p cross-section at three values of Q 2 : 0.255, 0.176 and 0.109 (GeV/c) 2 . The electrons were detected with the OHIPS magnetic spectrometer, and the neutrons were detected in a liquid mineral oil scintillator array. The measurement were made at a fixed neutron angle of θ n = 57 degrees; the Q 2 values were obtained by varying the incident electron energy and the scattering angle. These cross sections are sensitive primarily to the neutron magnetic form factor at these quasifree kinematics. The efficiency of the neutron detector was determined by the associated particle technique with the d(γ, pn) reaction for each of three neutron kinetic energies. The value of G n M extracted from the cross sections are consistent with the dipole parametrization at the two high momentum transfers; at the lowest momentum transfer the value of G n M is 10% higher than the dipole model. This enhancement at low momentum transfer is consistent with previous measurements

  12. Characteristics of A-150 plastic equivalent gas in A-150 plastic ionization chambers for p(66)Be(49) neutrons

    International Nuclear Information System (INIS)

    Awschalom, M.; Rosenberg, I.; Ten Haken, R.K.; Pearson, D.W.; DeLuca, P.M. Jr.; Attix, F.H.

    1982-01-01

    The average energy necessary to produce an electron-ion pair (anti W) of a gas mixture having an atomic composition very close to that of A-150 plastic has been studied through use in different size ionization chambers made of that plastic in a p(66)Be(49) neutron therapy beam. A tentative value for anti W(A-150-gas) of 27.3 +/ -0.5 J C -1 was derived. The anti W value of the A-150 equivalent gas mixture is compared to those of methane-based tissue-equivalent gas and of air for the p(66)Be(49) neutron beam as well as to corresponding values found in similar experiments using 14.8 MeV monoenergetic neutrons

  13. Accelerator based neutron source for neutron capture therapy

    International Nuclear Information System (INIS)

    Salimov, R.; Bayanov, B.; Belchenko, Yu.; Belov, V.; Davydenko, V.; Donin, A.; Dranichnikov, A.; Ivanov, A.; Kandaurov, I; Kraynov, G.; Krivenko, A.; Kudryavtsev, A.; Kursanov, N.; Savkin, V.; Shirokov, V.; Sorokin, I.; Taskaev, S.; Tiunov, M.

    2004-01-01

    Full text: The Budker Institute of Nuclear Physics (Novosibirsk) and the Institute of Physics and Power Engineering (Obninsk) have proposed an accelerator based neutron source for neutron capture and fast neutron therapy for hospital. Innovative approach is based upon vacuum insulation tandem accelerator (VITA) and near threshold 7 Li(p,n) 7 Be neutron generation. Pilot accelerator based neutron source for neutron capture therapy is under construction now at the Budker Institute of Nuclear Physics, Novosibirsk, Russia. In the present report, the pilot facility design is presented and discussed. Design features of facility components are discussed. Results of experiments and simulations are presented. Complete experimental tests are planned by the end of the year 2005

  14. GRACE manual

    International Nuclear Information System (INIS)

    Ishikawa, T.; Kawabata, S.; Shimizu, Y.; Kaneko, T.; Kato, K.; Tanaka, H.

    1993-02-01

    This manual is composed of three kinds of objects, theoretical background for calculating the cross section of elementary process, usage and technical details of the GRACE system. Throughout this manual we take the tree level process e + e - → W + W - γ as an example, including the e ± -scalar boson interactions. The real FORTRAN source code for this process is attached in the relevant sections as well as the results of calculation, which might be a great help for understanding the practical use of the system. (J.P.N.)

  15. P-glycoprotein confers acquired resistance to 17-DMAG in lung cancers with an ALK rearrangement

    International Nuclear Information System (INIS)

    Kim, Hee Joung; Lee, Kye Young; Kim, Young Whan; Choi, Yun Jung; Lee, Jung-Eun; Choi, Chang Min; Baek, In-Jeoung; Rho, Jin Kyung; Lee, Jae Cheol

    2015-01-01

    Because anaplastic lymphoma kinase (ALK) is dependent on Hsp90 for protein stability, Hsp90 inhibitors are effective in controlling growth of lung cancer cells with ALK rearrangement. We investigated the mechanism of acquired resistance to 17-(Dimethylaminoethylamino)-17-demethoxygeldanamycin (17-DMAG), a geldanamycin analogue Hsp90 inhibitor, in H3122 and H2228 non-small cell lung cancer cell lines with ALK rearrangement. Resistant cell lines (H3122/DR-1, H3122/DR-2 and H2228/DR) were established by repeated exposure to increasing concentrations of 17-DMAG. Mechanisms for resistance by either NAD(P)H/quinone oxidoreductase 1 (NQO1), previously known as a factor related to 17-DMAG resistance, or P-glycoprotein (P-gp; ABCB1/MDR1) were queried using RT-PCR, western blot analysis, chemical inhibitors, the MTT cell proliferation/survival assay, and cellular efflux of rhodamine 123. The resistant cells showed no cross-resistance to AUY922 or ALK inhibitors, suggesting that ALK dependency persists in cells with acquired resistance to 17-DMAG. Although expression of NQO1 was decreased in H3122/DR-1 and H3122/DR-2, NQO1 inhibition by dicumarol did not affect the response of parental cells (H2228 and H3122) to 17-DMAG. Interestingly, all resistant cells showed the induction of P-gp at the protein and RNA levels, which was associated with an increased efflux of the P-gp substrate rhodamine 123 (Rho123). Transfection with siRNA directed against P-gp or treatment with verapamil, an inhibitor of P-gp, restored the sensitivity to the drug in all cells with acquired resistance to 17-DMAG. Furthermore, we also observed that the growth-inhibitory effect of 17-DMAG was decreased in A549/PR and H460/PR cells generated to over-express P-gp by long-term exposure to paclitaxel, and these cells recovered their sensitivity to 17-DMAG through the inhibition of P-gp. P-gp over-expression is a possible mechanism of acquired resistance to 17-DMAG in cells with ALK rearrangement. The online

  16. Laboratory training manual on the use of isotopes and radiation in entomology. 2. ed.

    International Nuclear Information System (INIS)

    1977-01-01

    The revised manual, which incorporates changes particularly regarding applied aspects, consists of 7 parts. Part 1 is divided into separate chapters on the properties of radionuclides and radiations; radiation detection and assay of radioactivity; radiation protection; tracer methodology; 15 N determination; and neutron moderation and γ-ray attentuation techniques. Part 2 is concerned with radiobiology. References and a bibliography are supplied with each part. Part 3 contains 17 mental exercises, part 4 laboratory exercises on a GM counter; a scintillation counter; contamination and decontamination; and exercises on basic utilization principles. Part 5 considers radioisotope uptake and excretion paths through the insect organism; principles of internal and external tagging; with emphasis on insect physiology and ecology; various experiments on insects, and insect sterilization using 60 Co and chemosterilants. Eight Appendices and a Glossary of some basic terms and concepts constitute parts 6 and 7, respectively

  17. Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices

    Directory of Open Access Journals (Sweden)

    Larry J. Miller

    2011-07-01

    Full Text Available Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bilateral biopsies with each device. Core samples were obtained in 66.7% of Manual insertions; 100% of Powered insertions (P=0.002. Initial mean biopsy core lengths were 11.1±4.5 mm for the Manual device; 17.0±6.8 mm for the Powered device (P<0.005. Pathology assessment for the Manual device showed a mean length of 6.1±5.6 mm, width of 1.0±0.7 mm, and volume of 11.0±10.8 mm3. Powered device measurements were mean length of 15.3±6.1 mm, width of 2.0±0.3 mm, and volume of 49.1±21.5 mm3 (P<0.001. The mean time to core ejection was 86 seconds for Manual device; 47 seconds for the Powered device (P<0.001. The mean second look overall pain score was 33.3 for the Manual device; 20.9 for the Powered (P=0.039. We conclude that the Powered biopsy device produces superior sized specimens, with less overall pain, in less time.

  18. Neutron and gamma probes: Their use in agronomy

    International Nuclear Information System (INIS)

    Bacchi, O.O.; Reichart, K.; Calvache, M.

    2002-01-01

    The concept of this training manual originated during a regional training workshop on the use of neutron probe in water and nutrient balance studies, organized in 1997 in the frame of an IAEA Regional Technical Co-operation Project for Latin America entitle Plant Nutrition, Water and Soil Management, for which the integrated approach was adopted. The original version (in Spanish) was a comprehensive manual covering theoretical and practical aspects required for the proper utilization of the equipment. The contributions of the peer reviewers, editors and technical translators of the three versions in English, French and Spanish have greatly enhanced the content and quality of the manual. It is hoped that this manual will be useful for future training events and serve as a key reference to soil/water scientists in the field of sustainable management of scarce water resources in both rain-fed and irrigated agricultural production systems

  19. Cosmogenic excess of 40K and the flux of fast neutrons in meteorites

    International Nuclear Information System (INIS)

    Stegmann, W.; Begemann, F.

    1975-01-01

    Results are reported of a mass spectrometric investigation of the content and isotopic composition of potassium from the mesosiderite Emery (silicate phase) and the chondrite Elenovka (bulk). Normalized to the Nier value of 39 K/ 41 K = 13.47, the 40 K in Emery (K-content 220 +- 25 ppm) was found to be enriched by (4.03 +- 0.30)%, the potassium from Elenovka (760 +- 50 ppm) to be indistinguishable from terrestrial potassium. Evidence is presented that the excess 40 K in the silicates from Emery (Ca-content 6.06 weight %) has been produced essentially by secondary cosmic ray neutrons via the 40 Ca(n,p)-reaction. The total excess of (2.57 +- 0.39) x 10 14 40 K-atoms/gCa together with the excitation function of the 40 Ca(n,p)-reaction and the neutron flux spectrum of Arnold, Honda and Lal yields a dose of fast neutrons (2 MeV 16 neutrons/cm 2 and an average flux during the cosmic ray exposure age T = (134 +- 12) Myrs of PHI = (17.4 +- 3.1) neutrons/cm 2 sec. (orig./BJ) [de

  20. Precise measurements of the thick target neutron yields of the 7Li(p,n) reaction

    International Nuclear Information System (INIS)

    Matysiak, W.; Prestwich, W.V.; Byun, S.H.

    2011-01-01

    Thick target neutron yield of the 7 Li(p,n) 7 Be reaction was measured in the proton energy range from 1.95 to 2.3 MeV by determining induced activity of the 7 Be. A HPGe detector was used to detect the 478 keV gamma-rays emitted through 7 Be decay. A series of irradiations with nominal proton energies of 1.95, 2.0, 2.1, 2.2, and 2.3 MeV were carried out. In an independent experiment, raw neutron spectra were collected by a 3 He ion chamber for the same series of proton energies. From the raw neutron spectra, it was noted, that the effective proton energies were lower than the nominal by 50-58 keV. After corrections for the proton energy offsets were applied, the measured neutron yields matched the analytically calculated yields within 20%. Long term stability of neutron yield was tested at two nominal proton energies, 2.1 and 1.95 MeV over an experimental period of one year. The results show that the yield at 2.1 MeV was stable within rmse variation coefficient of 4.7% and remained consistent even when the lithium target was replaced, whereas at 1.95 MeV, the maximum fluctuations reached a factor of 10.

  1. Waterproofing with polymeric geo synthetic barriers (GBR-P) in the manual for the design, construction, management and maintenance of reservoirs; La impermeabilizacion con barreras geosinteticas polimericas (GBR-P) en el manual para el diseno, construccion, explotacion y mantenimiento de balsas

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, M.; Cea, J. C.; Garcia, F.; Sanchez, F. J.; Castillo, F.; Mora, J.; Crespo, M. A.

    2010-07-01

    This article presents a part of Manual for the Design, Construction, Management and Maintenance of Reservoirs relative to waterproofing with Polymeric Geo synthetic Barriers (GBR-P). the nature materials of geo membranes is studied also theirs characteristics and specifications. (Author) 26 refs.

  2. The measurements of thermal neutron flux distribution in a paraffin ...

    Indian Academy of Sciences (India)

    outputs and the best agreement was generated using NaI(Tl) by a minimum discrepancy of .... the four possible reactions with neutron absorption, our desire is to form 116m1In, which .... According to Geiger user's manual, its efficiency for.

  3. Neutron multiplicity for neutron induced fission of 235U, 238U, and 239Pu as a function of neutron energy

    International Nuclear Information System (INIS)

    Zucker, M.S.; Holden, N.E.

    1986-01-01

    Recent development in the theory and practice of neutron correlation (''coincidence'') counting require knowledge of the higher factorial moments of the P/sub ν/ distribution (the probability that (ν) neutrons are emitted in a fission) for the case where the fission is induced by bombarding neutrons of more than thermal energies. In contrast to the situation with spontaneous and thermal neutron induced fission, where with a few exceptions the P/sub ν/ is reasonably well known, in the fast neutron energy region, almost no information is available concerning the multiplicity beyond the average value, [ν], even for the most important nuclides. The reason for this is the difficulty of such experiments, with consequent statistically poor and physically inconsistent results

  4. Use of an immunodominant p17 antigenic fraction of Neospora caninum in detection of antibody response in cattle

    Directory of Open Access Journals (Sweden)

    Gema Álvarez García

    2006-08-01

    Full Text Available A Neospora caninum 17 kDa protein fraction (p17 has been described as an immunodominant antigen (IDA under reducing and non-reducing conditions. The aim of the present study was to investigate the diagnostic utility of p17 in cattle. In order to achieve this, p17 was purified by electroelution from whole N. caninum tachyzoite soluble extract and a p17-based Western blot (WB-p17 was developed. The p17 recognition was measured by densitometry and expressed as OD values to check the validity of the WB-p17. A total of 131 sera including sequential samples from naturally- and experimentally-infected calves and breeding cattle were analysed by WB-p17 and compared with IFAT using whole formalin-fixed tachyzoites as a reference test. The results obtained highlight the feasibility of using the N. caninum p17 in a diagnostic test in cattle. Firstly, the assay based on the p-17 antigen discriminated between known positive and negative sera from different cattle populations, breeding cattle and calves. Secondly, the p17 antigen detected fluctuations in the antibody levels and seroconversion in naturally- and experimentally-infected cattle. Significant differences in p-17 antigen recognition were observed between naturally infected aborting and non-aborting cattle, as well as significant antibody fluctuations over time in experimentally infected cattle, which varied between groups. Furthermore, the results obtained with WB-p17 are in accordance with the results obtained with the IFAT, as high agreement values were obtained when all bovine subpopulations were included (kappa = 0.86.

  5. Solution of two-dimensional equations of neutron transport in 4P0-approximation of spherical harmonics method

    International Nuclear Information System (INIS)

    Polivanskij, V.P.

    1989-01-01

    The method to solve two-dimensional equations of neutron transport using 4P 0 -approximation is presented. Previously such approach was efficiently used for the solution of one-dimensional problems. New an attempt is made to apply the approach to solution of two-dimensional problems. Algorithm of the solution is given, as well as results of test neutron-physical calculations. A considerable as compared with diffusion approximation is shown. 11 refs

  6. Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in Korea.

    Science.gov (United States)

    Kim, Sehun; Park, Jin Joo; Lee, Seung-Ah; Cho, Youngjin; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Cho, Young-Seok; Youn, Tae-Jin; Cho, Goo-Yeong; Chae, In-Ho; Lee, Hae-Young; Shin, Jinho; Park, Sungha; Choi, Dong-Ju

    2018-01-01

    Currently, office blood pressure (OBP) is the most widely used method of measuring blood pressure (BP) in daily clinical practice. However, data on the diagnostic accuracy of OBP in reference to ambulatory blood pressure (ABP) are scarce in Korea. In retrospective and prospective cohorts, manual OBP and ABP measurements were compared among ambulatory hypertensive patients. Hypertension was defined as systolic OBP ≥ 140 mmHg and/or diastolic OBP ≥ 90 mmHg, and systolic ABP ≥ 130 mmHg and/or diastolic ABP ≥ 80 mmHg. In the retrospective cohort (n = 903), the mean OBP1 (before ABP measurement) was higher than ABP in both systolic (138 ± 17 mmHg vs. 123 ± 13 mmHg, p ABP ( r 2 = 0.038, p ABP, which is the reference method for measuring BP, was 43.9%. The prospective cohort (n = 57) showed similar results. In a subgroup analysis, male patients had higher false negative results (masked or under-treated hypertension) than did female patients (26.1% vs. 17.8%, p = 0.003), whereas female patients had a higher false positive rate (white-coat or over-treated hypertension) than did male patients (28.7% vs. 15.2%, p ABP. Men and women have different patterns of discordance. These findings indicate that management of hypertensive patients with manual OBP measurements may be suboptimal and encourages the use of ABP in ambulatory hypertensive patients.

  7. SRAC2006: A comprehensive neutronics calculation code system

    International Nuclear Information System (INIS)

    Okumura, Keisuke; Kugo, Teruhiko; Kaneko, Kunio; Tsuchihashi, Keichiro

    2007-02-01

    The SRAC is a code system applicable to neutronics analysis of a variety of reactor types. Since the publication of the second version of the users manual (JAERI-1302) in 1986 for the SRAC system, a number of additions and modifications to the functions and the library data have been made to establish a comprehensive neutronics code system. The current system includes major neutron data libraries (JENDL-3.3, JENDL-3.2, ENDF/B-VII, ENDF/B-VI.8, JEFF-3.1, JEF-2.2, etc.), and integrates five elementary codes for neutron transport and diffusion calculation; PIJ based on the collision probability method applicable to 16 kind of lattice models, S N transport codes ANISN(1D) and TWOTRN(2D), diffusion codes TUD(1D) and CITATION(multi-D). The system also includes an auxiliary code COREBN for multi-dimensional core burn-up calculation. (author)

  8. A Rapid ELISA Method for 17, 20b-dihydroxy-4-pregenen-3-one (17,20bP Hormone Using Acetylcholinesterase Enzyme as Tracer

    Directory of Open Access Journals (Sweden)

    M Ebrahimi

    2004-06-01

    Full Text Available Background: During the past 15 years Enzyme Linked ImmunoSorbent Assay (ELISA has been described as an alternative to radioimmunoassay for steroid detection. In addition to gonads, sperm itself is capable of producing reduced progesterone metabolites. In this study we introduced a method to extend the applicability of previous measures by describing a general preparation procedure for the enzyme label which is applicable to any steroid hormone. Methods: A simple and rapid Enzyme Linked Immunosorbant Assay (ELISA is described and validated for 17,20β- dihydroxy-4-pregnen-3-one (17,20βP. A general procedure for preparation of the acetylcholinesterase labelled steroid is described which is applicable to any steroid. Results: Use of acetylcholinesterase tracer increased the sensitivity of assay so that reliable measurements of each steroid could be achieved with only 10 µl of plasma. ELISA was applied to measure of 17,20βP steroid production by sperm of trout which has sufficient amount of potent and active 20βHSD enzyme to convert 17α-hydroxy-4-pregnen-3-one (17αP substrate to 17,20βP product. The results showed that a clear shift in 17,20βP production was found with increase in substrate concentration in all in vitro incubations. Conclusion: ELISA method presented in this study has greater sensitivity and accuracy compared to previously described method that uses radiolabelled substances. Keywords: Immunoassay, ELISA, Steroids, Hormone, Assay

  9. Ciclon: A neutronic fuel management program for PWR's consecutive cycles

    International Nuclear Information System (INIS)

    Aragones, J.M.

    1977-01-01

    The program description and user's manual of a new computer code is given. Ciclon performs the neutronic calculation of consecutive reload cycles for PWR's fuel management optimization. Fuel characteristics and burnup data, region or batch sizes, loading schemes and state of previously irradiated fuel are input to the code. Cycle lengths or feed enrichments and burnup sharing for each region or batch are calculate using different core neutronic models and printed or punched in standard fuel management format. (author) [es

  10. Automation of angular movement of the arm neutron diffractometer; Automatizacion del movimiento angular del brazo del difractometro de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar H, F.; Herrera A, E.; Quintana C, G. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Torres R, C. E.; Reyes V, M., E-mail: fortunato.aguilar@inin.gob.mx [Instituto Tecnologico de Toluca, Av. Tecnologico s/n, Ex-Rancho La Virgen, Metepec, Estado de Mexico (Mexico)

    2015-09-15

    A technique to determine the crystal structure of some materials is the neutron diffraction. This technique consists on placing the material in question in a monoenergetic neutron beam obtained by neutron diffraction in a monochromator crystal. The neutron energy depends of the diffraction angle. The Instituto Nacional de Investigaciones Nucleares has a neutron diffractometer and monochromator crystals of pyrolytic graphite. This crystal can be selecting the neutron energy depending on the angle of diffraction in the glass. The radiation source for the neutron diffractometer is the TRIGA Mark III reactor of the Nuclear Center Dr. Nabor Carrillo Flores. During their operation are also obtained besides neutrons, β and γ radiation. The interest is to have thermal neutrons, so fast neutrons and γ rays are removed using appropriate shielding. The average neutron fluxes of the radial port RE2 of neutron diffractometer at power 1 MW are: heat flow 2,466 x 10{sup 8} n cm{sup -2} sec{sup -1} and fast flow 1,239 x 10{sup 8} n cm{sup -2} sec{sup -1}. The neutron detector is housed in a shield mounted on a mechanical linkage with which the diffraction angle is selected, and therefore the energy of the neutrons. The movement of this joint was performed by the equipment operator manually, so that accuracy to select the diffraction angle was not good and the process rather slow. Therefore a mechanical system was designed, automated by means of a motor as an actuator, a system of force transmission and an electronic control in order that the operator will schedule the diffraction angles and allow the count in the neutrons detection system in a simple manner. (Author)

  11. Boron neutron capture therapy of glioblastoma multiforme using the p- boronophenylalanine-fructose complex and epithermal neutrons

    International Nuclear Information System (INIS)

    Coderre, J.A.; Chanana, A.D.; Joel, D.D.; Liu, H.B.; Slatkin, D.N.; Wielopolski, L.; Bergland, R.; Elowitz, E.; Chadha, M.

    1994-01-01

    The amino acid analogue p-boronophenylalanine (BPA) is under investigation as a neutron capture agent for BNCT of glioblastoma multiforme. A series of patients undergoing surgical removal of tumor received BPA orally as the free amino acid. Favorable tumor/blood boron concentration ratios were obtained but the absolute amount of boron in the tumor would have been insufficient for BNCT. BPA can be solubilized at neutral pH by complexation with fructose (BPA-F). Studies with rats suggest that intraperitoneal injection of BPA-F complex produces a much higher tumor boron concentration to rat intracerebral 9L gliosarcoma that were possible with oral BPA. Higher boron concentrations have allowed higher tumor radiation doses to be delivered while maintaining the dose to the normal brain vascular endothelium below the threshold of tolerance. The experience to date of the administration of BPA-F to one patient is provided in this report

  12. Boron neutron capture therapy of glioblastoma multiforme using the p- boronophenylalanine-fructose complex and epithermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Coderre, J.A.; Chanana, A.D.; Joel, D.D.; Liu, H.B.; Slatkin, D.N.; Wielopolski, L. [Brookhaven National Lab., Upton, NY (United States); Bergland, R.; Elowitz, E. [Beth Israel Medical Center, New York, NY (United States). Dept. of Neurosurgery; Chadha, M. [Beth Israel Medical Center, New York, NY (United States). Dept. of Radiation Oncology

    1994-12-31

    The amino acid analogue p-boronophenylalanine (BPA) is under investigation as a neutron capture agent for BNCT of glioblastoma multiforme. A series of patients undergoing surgical removal of tumor received BPA orally as the free amino acid. Favorable tumor/blood boron concentration ratios were obtained but the absolute amount of boron in the tumor would have been insufficient for BNCT. BPA can be solubilized at neutral pH by complexation with fructose (BPA-F). Studies with rats suggest that intraperitoneal injection of BPA-F complex produces a much higher tumor boron concentration to rat intracerebral 9L gliosarcoma that were possible with oral BPA. Higher boron concentrations have allowed higher tumor radiation doses to be delivered while maintaining the dose to the normal brain vascular endothelium below the threshold of tolerance. The experience to date of the administration of BPA-F to one patient is provided in this report.

  13. Accuracy of manual entry of drug administration data into an anesthesia information management system.

    Science.gov (United States)

    Avidan, Alexander; Dotan, Koren; Weissman, Charles; Cohen, Matan J; Levin, Phillip D

    2014-11-01

    Data on drug administration are entered manually into anesthesia information management systems (AIMS). This study examined whether these data are accurate regarding drug name, dose administered, and time of administration, and whether the stage of anesthesia influences data accuracy. Real-time observational data on drug administration during elective operations were compared with computerized information on drug administration entered by anesthesiologists. A trained observer (K.D.) performed the observations. Data were collected during 57 operations which included 596 separate occasions of drug administration by 22 anesthesiologists. No AIMS records were found for 90 (15.1%) occasions of drug administration (omissions), while there were 11 (1.8%) AIMS records where drug administration was not observed. The AIMS and observer data matched for drug name on 495 of 596 (83.1%) occasions, for dose on 439 of 495 (92.5%) occasions, and for time on 476 of 495 (96.2%) occasions. Amongst the 90 omitted records, 34 (37.8%) were for vasoactive drugs with 24 (27.7%) for small doses of hypnotics. Omissions occurred mostly during maintenance: 50 of 153 (24.6%), followed by induction: 30 of 325 (9.2%) and emergence: 10 of 57 (17.5%) (P < 0.001). Time and dose inaccuracies occurred mainly during induction, followed by maintenance and emergence; time inaccuracies were 7/325 (8.3%), 10/203 (4.9%), and 0/57 (0%), respectively (P = 0.07), and dose inaccuracies were 15/325 (4.6%), 3/203 (1.5%), and 1/57 (1.7%), respectively (P = 0.11). The range of accuracy varies when anesthesiologists manually enter drug administration data into an AIMS. Charting omissions represent the largest cause of inaccuracy, principally by omissions of records for vasopressors and small doses of hypnotic drugs. Manually entered drug administration data are not without errors. Accuracy of entering drug administration data remains the responsibility of the anesthesiologist.

  14. Systematic determination of the JET absolute neutron yield using the MPR spectrometer

    International Nuclear Information System (INIS)

    Kronborg-Pettersson, N.

    2003-04-01

    This thesis describes the first high-statistics systematic analysis of JET neutron yield and rate measurements obtained by using data acquired with the Magnetic Proton Recoil (MPR) neutron spectrometer. The neutron yield and rate were determined by using the count-rate from the MPR neutron spectrometer together with neutron profile information from other neutron diagnostic systems. This has previously been done manually for a few pulses. To be able to do this in a more systematic way a part of the neutron spectrum evaluation code was extracted and put into a separate custom-made program and modifications were done to extract sets of MPR data automatically. The codes have been used for analysis of a large set of pulses from the deuterium-tritium campaign at JET in 1997. Several results were obtained, the most significant of which was the clear improvement seen when neutron profile corrections were applied. Neutron yield-rates derived from MPR count-rate are shown to be in excellent agreement with other JET neutron diagnostic data

  15. Systematic determination of the JET absolute neutron yield using the MPR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kronborg-Pettersson, N

    2003-04-01

    This thesis describes the first high-statistics systematic analysis of JET neutron yield and rate measurements obtained by using data acquired with the Magnetic Proton Recoil (MPR) neutron spectrometer. The neutron yield and rate were determined by using the count-rate from the MPR neutron spectrometer together with neutron profile information from other neutron diagnostic systems. This has previously been done manually for a few pulses. To be able to do this in a more systematic way a part of the neutron spectrum evaluation code was extracted and put into a separate custom-made program and modifications were done to extract sets of MPR data automatically. The codes have been used for analysis of a large set of pulses from the deuterium-tritium campaign at JET in 1997. Several results were obtained, the most significant of which was the clear improvement seen when neutron profile corrections were applied. Neutron yield-rates derived from MPR count-rate are shown to be in excellent agreement with other JET neutron diagnostic data.

  16. Experiments on neutron-proton and neutron-electron interaction

    International Nuclear Information System (INIS)

    Koester, L.

    1975-01-01

    The paper reports on zero-energy experiments with neutrons, protons and electrons with a wavelength that is considerably longer than the particle expansion. Scattering amplitudes are measured for the reactions n + p and n + e. A neutron gravity refractometer is used. (WL/AK) [de

  17. Photoneutron cross sections measurements in 9Be, 13C e 17O with thermal neutron capture gamma-rays

    International Nuclear Information System (INIS)

    Semmler, Renato

    2006-01-01

    Photoneutron cross sections measurements of 9 Be, 13 C and 17 O have been obtained in the energy interval between 1,6 and 10,8 MeV, using neutron capture gamma-rays with high resolution in energy (3 a 21 eV), produced by 21 target materials, placed inside a tangential beam port, near the core of the IPEN/CNEN-SP IEA-R1 (5 MW) research reactor. The samples have been irradiated inside a 4π geometry neutron detector system 'Long Counter', 520,5 cm away from the capture target. The capture gamma-ray flux was determined by means of the analysis of the gamma spectrum obtained by using a Ge(Li) solid-state detector (EG and G ORTEC, 25 cm 3 , 5%), previously calibrated with capture gamma-rays from a standard target of Nitrogen (Melamine). The neutron photoproduction cross section has been measured for each target capture gamma-ray spectrum (compound cross section). A inversion matrix methodology to solve inversion problems for unfolding the set of experimental compound cross sections, was used in order to obtain the cross sections at specific excitation energy values (principal gamma line energies of the capture targets). The cross sections obtained at the energy values of the principal gamma lines were compared with experimental data reported by other authors, with have employed different gamma-ray sources. A good agreement was observed among the experimental data in this work with reported in the literature. (author)

  18. Study of neutron fields around an intense neutron generator.

    Science.gov (United States)

    Kicka, L; Machrafi, R; Miller, A

    2017-12-01

    Neutron fields in the vicinity of the newly built neutron facility, at the University of Ontario Institute of Technology (UOIT), have been investigated in a series of Monte Carlo simulations and measurements. The facility hosts a P-385 neutron generator based on a deuterium-deuterium fusion reaction. The neutron fluence at different locations around the neutron generator facility has been simulated using MCNPX 2.7E Monte Carlo particle transport program. To characterize neutron fields, three neutron sources were modeled with distributions corresponding to different incident deuteron energies of 90kV, 110kV, and 130kV. Measurements have been carried out to determine the dose rate at locations adjacent to the generator using bubble detectors (BDs). The neutron intensity was evaluated and the total dose rates corresponding to different applied acceleration potentials were estimated at various locations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Oculocutaneous albinism in a patient with 17p13.2-pter duplication - a review on the molecular syndromology of 17p13 duplication.

    Science.gov (United States)

    Kucharczyk, Marzena; Jezela-Stanek, Aleksandra; Gieruszczak-Bialek, Dorota; Kugaudo, Monika; Cieslikowska, Agata; Pelc, Magdalena; Krajewska-Walasek, Malgorzata

    2015-06-01

    Chromosomal duplications involving 17p13.3 have recently been defined as a new distinctive syndrome with several diagnosed patients. Some variation is known to occur in the breakpoints of the duplicated region and, consequently, in the phenotype as well. We report on a patient, the fifth to our knowledge, a 4-year-old girl with a pure de novo subtelomeric 17p13.2-pter duplication. She presents all of the facial features described so far for this duplication and in addition, a unilateral palmar transversal crease and oculocutaneous albinism which has not been reported previously. A detailed molecular description of the reported aberration and correlation with the observed phenotypical features based on a literature review. We discuss the possible molecular etiology of albinism in regard to the mode of inheritance. The new data provided here may be useful for further genotype correlations in syndromes with oculocutaneous albinism, especially of autosomal dominant inheritance.

  20. Comparison of DVH parameters and loading patterns of standard loading, manual and inverse optimization for intracavitary brachytherapy on a subset of tandem/ovoid cases

    International Nuclear Information System (INIS)

    Jamema, Swamidas V.; Kirisits, Christian; Mahantshetty, Umesh; Trnkova, Petra; Deshpande, Deepak D.; Shrivastava, Shyam K.; Poetter, Richard

    2010-01-01

    Purpose: Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns. Materials and methods: Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized. Dosimetric outcomes from these plans were compared based on dose-volume parameters. The ratio of Total Reference Air Kerma of ovoid to tandem (TRAK O/T ) was used to compare the loading patterns. Results: The volume of HR CTV ranged from 9-68 cc with a mean of 41(±16.2)cc. Mean V100 for standard, manual optimized and inverse plans was found to be not significant (p = 0.35, 0.38, 0.4). Dose to bladder (7.8 ± 1.6 Gy) and sigmoid (5.6 ± 1.4 Gy) was high for standard plans; Manual optimization reduced the dose to bladder (7.1 ± 1.7 Gy p = 0.006) and sigmoid (4.5 ± 1.0 Gy p = 0.005) without compromising the HR CTV coverage. The inverse plan resulted in a significant reduction to bladder dose (6.5 ± 1.4 Gy, p = 0.002). TRAK was found to be 0.49(±0.02), 0.44(±0.04) and 0.40(±0.04)cGy m -2 for the standard loading, manual optimized and inverse plans, respectively. It was observed that TRAK O/T was 0.82(±0.05), 1.7(±1.04) and 1.41(±0.93) for standard loading, manual optimized and inverse plans, respectively, while this ratio was 1 for the traditional loading pattern. Conclusions: Inverse planning offers good sparing of critical structures without compromising the target coverage. The average loading pattern of the whole patient cohort deviates from the standard Fletcher loading pattern.

  1. Comparison of DVH parameters and loading patterns of standard loading, manual and inverse optimization for intracavitary brachytherapy on a subset of tandem/ovoid cases.

    Science.gov (United States)

    Jamema, Swamidas V; Kirisits, Christian; Mahantshetty, Umesh; Trnkova, Petra; Deshpande, Deepak D; Shrivastava, Shyam K; Pötter, Richard

    2010-12-01

    Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns. Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized. Dosimetric outcomes from these plans were compared based on dose-volume parameters. The ratio of Total Reference Air Kerma of ovoid to tandem (TRAK(O/T)) was used to compare the loading patterns. The volume of HR CTV ranged from 9-68 cc with a mean of 41(±16.2) cc. Mean V100 for standard, manual optimized and inverse plans was found to be not significant (p=0.35, 0.38, 0.4). Dose to bladder (7.8±1.6 Gy) and sigmoid (5.6±1.4 Gy) was high for standard plans; Manual optimization reduced the dose to bladder (7.1±1.7 Gy p=0.006) and sigmoid (4.5±1.0 Gy p=0.005) without compromising the HR CTV coverage. The inverse plan resulted in a significant reduction to bladder dose (6.5±1.4 Gy, p=0.002). TRAK was found to be 0.49(±0.02), 0.44(±0.04) and 0.40(±0.04) cGy m(-2) for the standard loading, manual optimized and inverse plans, respectively. It was observed that TRAK(O/T) was 0.82(±0.05), 1.7(±1.04) and 1.41(±0.93) for standard loading, manual optimized and inverse plans, respectively, while this ratio was 1 for the traditional loading pattern. Inverse planning offers good sparing of critical structures without compromising the target coverage. The average loading pattern of the whole patient cohort deviates from the standard Fletcher loading pattern. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Neutron activation determination of phosphorus and sulfur in semiconductor materials by 32P-isotope

    International Nuclear Information System (INIS)

    Nikolaev, A.V.; Gol'dshtejn, M.M.; Gil'bert, Eh.N.; Verevkin, G.V.; Yudelevich, I.G.

    1977-01-01

    A neutron-activation method has been developed for determining phosphorus and sulphur in germanium, gallium, gallium arsenide, and silicon structures using 32 P isotope. The dioctyl-sulphoxide (DOSO) extraction of phosphoric molybdenum acid (PMA) has been used to separate 32 P in a radiochemically pure form. Correction factors have been calculated due to the 2nd order interference on 30 Si nuclei in determining phosphorus in silicon for various irradiation times and at various cadmium proportions

  3. European correlation counter (ECC) VER. 1.0 users manual

    International Nuclear Information System (INIS)

    Vocino, V.

    1989-01-01

    The users manual is conceived for the utilization of personal computers linked to a shift register for the assay of Pu containing fuel. It is based on an MS DOS system and permits the users to store calibration curves, constants, measurement and assay data on floppy disks for ulterior utilisation. The interpretation models use the latest theories of neutron multiplication and dead time effects. The inspector is guided by the screen display step by step from the instrument test via calibration to the assay and data storage. All test, calibration and assay data can be printed out on paper tape and serve to the inspector to prepare the respective inspection report. The users are invited to make suggestions to the authors, such that the manual's use can be adapted to further requirements

  4. Effect of neutron and gamma radiations on zeolite and zeotype materials

    International Nuclear Information System (INIS)

    Durrani, S.K.

    1994-01-01

    The influence of gamma and (n, gamma)-radiation on the cation exchange and the structure of zeolite and zeotype materials has been studied. Samples were subjected to different doses of gamma-irradiation varying between 0.5 and 10 MGy and Neutron irradiation flux varied from 1.14 x 10/sup 17/ to 3.88 x /sup 10/sup 17/n cm/sup -2/. Structural effects consequent to gamma irradiation were examined by x-ray diffraction, electron scanning micrographs and FTIR measurements. Neutron and gamma-irradiation and not lead by any appreciable change in the structure, however, the displacement cations to locked-in sites results partial reduced barium and caesium uptake. The decrease of the intensities of the absorption bands of the hydroxy-groups reveals that gamma-irradiation has a strong dehydrating influence. THe effects of gamma-radiation on (UO/sub 2/)/sup 2+/ and Am/sup 3+/ uptake into NH/sub 4/-L and NH/sub 4/-SAPO-34 was also observed. K alpha of the uranyl ions increased with increasing pH up to 6.3. At pH > 3.5, the uranyl ions were precipitated and consequently K alpha values were continued to increased. (author)

  5. Construction of a time-of-flight neutron spectrometer for reaction angles 000 and study of the reaction 65Cu(p,xn) 65Zn for Esub(p)=26.7 MeV

    International Nuclear Information System (INIS)

    Holler, Y.

    1984-01-01

    At the Hamburg Isochronous Cyclotron a novel time-of-flight neutron spectrometer was designed, constructed, and tested by means of a for the planned application typical nuclear reaction. The apparature was optimized for the measurement of continuous, structure-deficient neutron spectra in a wide angular range at a reproducible, as low as possible scattering neutron background. Such a facility is fitted to the strengths of the Hamburg cyclotron and allows to study questions on the precompound emission and on the inelastic projectile ( 3 He) breakup. The final test was performed with the reaction 65 Cu(p,xn) 65 Zn at Esub(p)=26.7 MeV for which already comparable data over a smaller angular range were present. In the analysis of the measurement results performed regarding the precompound effects the hybrid-exciton model calculations let recognize essential deviations at high neutron energies in the range of the extreme reaction angles. (orig./HSI) [de

  6. High-power electron beam tests of a liquid-lithium target and characterization study of (7)Li(p,n) near-threshold neutrons for accelerator-based boron neutron capture therapy.

    Science.gov (United States)

    Halfon, S; Paul, M; Arenshtam, A; Berkovits, D; Cohen, D; Eliyahu, I; Kijel, D; Mardor, I; Silverman, I

    2014-06-01

    A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center (SNRC). The target is intended to demonstrate liquid-lithium target capabilities to constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals. The lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power >5kW generated by high-intensity proton beams, necessary for sufficient therapeutic neutron flux. In preliminary experiments liquid lithium was flown through the target loop and generated a stable jet on the concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power densities of more than 4kW/cm(2) and volumetric power density around 2MW/cm(3) at a lithium flow of ~4m/s, while maintaining stable temperature and vacuum conditions. These power densities correspond to a narrow (σ=~2mm) 1.91MeV, 3mA proton beam. A high-intensity proton beam irradiation (1.91-2.5MeV, 2mA) is being commissioned at the SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator. In order to determine the conditions of LiLiT proton irradiation for BNCT and to tailor the neutron energy spectrum, a characterization of near threshold (~1.91MeV) (7)Li(p,n) neutrons is in progress based on Monte-Carlo (MCNP and Geant4) simulation and on low-intensity experiments with solid LiF targets. In-phantom dosimetry measurements are performed using special designed dosimeters based on CR-39 track detectors. © 2013 Elsevier Ltd. All rights reserved.

  7. Manual for the Epithermal Neutron Multiplicity Detector (ENMC) for Measurement of Impure MOX and Plutonium Samples

    International Nuclear Information System (INIS)

    Menlove, H. O.; Rael, C. D.; Kroncke, K. E.; DeAguero, K. J.

    2004-01-01

    We have designed a high-efficiency neutron detector for passive neutron coincidence and multiplicity counting of dirty scrap and bulk samples of plutonium. The counter will be used for the measurement of impure plutonium samples at the JNC MOX fabrication facility in Japan. The counter can also be used to create working standards from bulk process MOX. The detector uses advanced design "3He tubes to increase the efficiency and to shorten the neutron die-away time. The efficiency is 64% and the die-away time is 19.1 ?s. The Epithermal Neutron Multiplicity Counter (ENMC) is designed for high-precision measurements of bulk plutonium samples with diameters of less than 200 mm. The average neutron energy from the sample can be measured using the ratio of the inner ring of He-3 tubes to the outer ring. This report describes the hardware, performance, and calibration for the ENMC.

  8. Study of fission barriers in neutron-rich nuclei using the (p,2p) reaction. Status of SAMURAI-experiment NP1306 SAMURAI14

    Energy Technology Data Exchange (ETDEWEB)

    Reichert, Sebastian [TU Munich (Germany); Collaboration: NP1306-SAMURAI14-Collaboration

    2015-07-01

    Violent stellar processes are currently assumed to be a major origin of the elements beyond iron and their abundances. The conditions during stellar explosions lead to the so called r-process in which the rapid capture of neutrons and subsequent β decays form heavier elements. This extension of the nuclei stops at the point when the repulsive Coulomb energy induces fission. Its recycling is one key aspect to describe the macroscopic structure of the r-process and the well known elemental abundance pattern. The RIBF at RIKEN is able to provide such neutron rich heavy element beams and a first test with the primary beam {sup 238}U was performed to understand the response of the SAMURAI spectrometer and detectors for heavy beams. The final goal is the definition of the fission barrier height with a resolution of 1 MeV (in σ) using the missing mass method using (p,2p) reactions in inverse kinematics.

  9. GANDALF: users' manual

    International Nuclear Information System (INIS)

    Strout, R.E. II; Beach, J.L.

    1977-01-01

    The GANDALF computer code was written to calculate neutron dose equivalent given the pulse-height data obtained by using a Linear Energy Transfer (LET) proportional counter. The code also uses pre- and/or post-calibration spectra, from an alpha source, to determine a calibration factor in keV/μ/channel. Output from the code consists of the effective radius of the detection chamber in microns, a calibration factor in keV/μ/channel, and the total dose and dose equivalent in rad or rem between any two LET energies by using the equations by Attix and Roesch [Radiation Dosimetry, 1, 71 (1968)]. This report is a user's manual and is not intended as anything else, and assumes that the user has a basic knowledge of the LLL Octopus timesharing system. However, a very brief description of how the code operates is included

  10. Gamma spectroscopic studies of the neutron-deficient g-g nucleus 74Kr by means of a neutron multiplicity measurement technique

    International Nuclear Information System (INIS)

    Roth, J.

    1981-01-01

    The g-g nucleus 74 Kr was studied by means of the reaction 58 Ni ( 19 F, p2n#betta#) 74 Kr. In order to make gamma spectroscopic studies at neutron deficient nuclei like 74 Kr a neutron multiplicity measurement technique was developed. Beside #betta# single spectra, #betta# excitation functions, #betta#-#betta# coincidences, #betta# angular distributions, and lifetime measurements by means of this technique all measurements in coincidence with up to two neutrons were taken up. From these measurement data an extended term scheme with 17 newly found excited states could be extracted. To all levels spins and parities could be assigned. From the four energetically lowest levels of the yrast cascade the mean lifetimes could be determined. A double backbending in the sequence of the yrast cascade was interpreted as crossing of the g 9/2 bands. The irregularities in the lower part of the yrast band correspond to the shape consistence picture. The results were considered in connection with the systematics of the even krypton isotopes and compared with a two-quasiparticle-plas-rotor model calculation. (HSI)

  11. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  12. Neutron Diffraction Residual Strain Tensor Measurements Within The Phase IA Weld Mock-up Plate P-5

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Camden R [ORNL

    2011-09-01

    Oak Ridge National Laboratory (ORNL) has worked with NRC and EPRI to apply neutron and X-ray diffraction methods to characterize the residual stresses in a number of dissimilar metal weld mockups and samples. The design of the Phase IA specimens aimed to enable stress measurements by several methods and computational modeling of the weld residual stresses. The partial groove in the 304L stainless steel plate was filled with weld beads of Alloy 82. A summary of the weld conditions for each plate is provided in Table 1. The plates were constrained along the long edges during and after welding by bolts with spring-loaded washers attached to the 1-inch thick Al backing plate. The purpose was to avoid stress relief due to bending of the welded stainless steel plate. The neutron diffraction method was one of the methods selected by EPRI for non-destructive through thickness strain and stress measurement. Four different plates (P-3 to P-6) were studied by neutron diffraction strain mapping, representing four different welding conditions. Through thickness neutron diffraction strain mappings at NRSF2 for the four plates and associated strain-free d-zero specimens involved measurement along seven lines across the weld and at six to seven depths. The mountings of each plate for neutron diffraction measurements were such that the diffraction vector was parallel to each of the three primary orthogonal directions of the plate: two in-plane directions, longitudinal and transverse, and the direction normal to the plate (shown in left figure within Table 1). From the three orthogonal strains for each location, the residual stresses along the three plate directions were calculated. The principal axes of the strain and stress tensors, however, need not necessarily align with the plate coordinate system. To explore this, plate P-5 was selected for examination of the possibility that the principal axes of strain are not along the sample coordinate system axes. If adequate data could

  13. FURNACE 2. Toroidal geometry neutronic program system method. Description and users manual

    Energy Technology Data Exchange (ETDEWEB)

    Verschuur, K.A.

    1995-10-01

    FURNACE2 is a 3-dimensional neutron/photon-transport program system for toroidal geometries. It uses ray-tracing and double-differential reflection-and transmission-coefficients and flux-kernels to calculate the angular-flux spectra inside the torus of a fusion-reactor. FURNACE2 is an extended version of FURNACE, developed for application to the neutron-diagnostics at JET, which was supported financially by JET. It is used at JET to calculate the foil-activation for the KN2 diagnostics, the angular-fluxes on the lines of sight of the KN3 profile monitors, and general background fluxes and activation of the vessel. The program is used along with MCNP, combining the advantages of each of the programs and for mutual checks. (orig.).

  14. FURNACE 2. Toroidal geometry neutronic program system method. Description and users manual

    International Nuclear Information System (INIS)

    Verschuur, K.A.

    1995-10-01

    FURNACE2 is a 3-dimensional neutron/photon-transport program system for toroidal geometries. It uses ray-tracing and double-differential reflection-and transmission-coefficients and flux-kernels to calculate the angular-flux spectra inside the torus of a fusion-reactor. FURNACE2 is an extended version of FURNACE, developed for application to the neutron-diagnostics at JET, which was supported financially by JET. It is used at JET to calculate the foil-activation for the KN2 diagnostics, the angular-fluxes on the lines of sight of the KN3 profile monitors, and general background fluxes and activation of the vessel. The program is used along with MCNP, combining the advantages of each of the programs and for mutual checks. (orig.)

  15. The structure of phosphate glass biomaterials from neutron diffraction and 31P nuclear magnetic resonance data

    International Nuclear Information System (INIS)

    Pickup, D M; Ahmed, I; Guerry, P; Knowles, J C; Smith, M E; Newport, R J

    2007-01-01

    Neutron diffraction and 31 P nuclear magnetic resonance spectroscopy were used to probe the structure of phosphate glass biomaterials of general composition (CaO) 0.5-x (Na 2 O) x (P 2 O 5 ) 0.5 (x = 0, 0.1 and 0.5). The results suggest that all three glasses have structures based on chains of Q 2 phosphate groups. Clear structural differences are observed between the glasses containing Na 2 O and CaO. The P-O bonds to bridging and non-bridging oxygens are less well resolved in the neutron data from the samples containing CaO, suggesting a change in the nature of the bonding as the field strength of the cation increases Na + → Ca 2+ . In the (CaO) 0.5 (P 2 O 5 ) 0.5 glass most of the Ca 2+ ions are present in isolated CaO x polyhedra whereas in the (Na 2 O) 0.5 (P 2 O 5 ) 0.5 glass the NaO x polyhedra share edges leading to a Na-Na correlation. The results of the structural study are related to the properties of the (CaO) 0.4 (Na 2 O) 0.1 (P 2 O 5 ) 0.5 biomaterial

  16. Early recurrence in standard-risk medulloblastoma patients with the common idic(17)(p11.2) rearrangement

    Science.gov (United States)

    Bien-Willner, Gabriel A.; López-Terrada, Dolores; Bhattacharjee, Meena B.; Patel, Kayuri U.; Stankiewicz, Paweł; Lupski, James R.; Pfeifer, John D.; Perry, Arie

    2012-01-01

    Medulloblastoma is diagnosed histologically; treatment depends on staging and age of onset. Whereas clinical factors identify a standard- and a high-risk population, these findings cannot differentiate which standard-risk patients will relapse and die. Outcome is thought to be influenced by tumor subtype and molecular alterations. Poor prognosis has been associated with isochromosome (i)17q in some but not all studies. In most instances, molecular investigations document that i17q is not a true isochromosome but rather an isodicentric chromosome, idic(17)(p11.2), with rearrangement breakpoints mapping within the REPA/REPB region on 17p11.2. This study explores the clinical utility of testing for idic(17)(p11.2) rearrangements using an assay based on fluorescent in situ hybridization (FISH). This test was applied to 58 consecutive standard- and high-risk medulloblastomas with a 5-year minimum of clinical follow-up. The presence of i17q (ie, including cases not involving the common breakpoint), idic(17)(p11.2), and histologic subtype was correlated with clinical outcome. Overall survival (OS) and disease-free survival (DFS) were consistent with literature reports. Fourteen patients (25%) had i17q, with 10 (18%) involving the common isodicentric rearrangement. The presence of i17q was associated with a poor prognosis. OS and DFS were poor in all cases with anaplasia (4), unresectable disease (7), and metastases at presentation (10); however, patients with standard-risk tumors fared better. Of these 44 cases, tumors with idic(17)(p11.2) were associated with significantly worse patient outcomes and shorter mean DFS. FISH detection of idic(17)(p11.2) may be useful for risk stratification in standard-risk patients. The presence of this abnormal chromosome is associated with early recurrence of medulloblastoma. PMID:22573308

  17. Determination of S- and P-strength functions using fast neutrons - having energy from 30 -360 keV; Odredjivanje S- i P-funkcije 'jacine veze' brzim neutronima - energija od 60 - 360 keV

    Energy Technology Data Exchange (ETDEWEB)

    Boreli, F M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1958-07-01

    Reaction Li{sup 7}(p,n)Be{sup 7} was used as a neutron source to determine the strength functions on a number of intermediate and heavy nuclei at average neutron energies from 60 - 360 keV. The strength functions were obtained by measuring the deviation from exponential attenuation of neutrons passing through the sample. Values obtained at lower energies showed dependence on the atomic weight predicted by the optical model and were in agreement with previous measurements. For the elements in the region A=90 the fast increase of strength function obtained by assuming only S-wave interactions suggests that P-wave interactions are taking place.

  18. RAMONA-4B a computer code with three-dimensional neutron kinetics for BWR and SBWR system transient - user's manual

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Cheng, H.S.; Khan, H.J.; Mallen, A.N.; Neymotin, L.Y.

    1998-03-01

    This document is the User's Manual for the Boiling Water Reactor (BWR), and Simplified Boiling Water Reactor (SBWR) systems transient code RAMONA-4B. The code uses a three-dimensional neutron-kinetics model coupled with a multichannel, nonequilibrium, drift-flux, phase-flow model of the thermal hydraulics of the reactor vessel. The code is designed to analyze a wide spectrum of BWR core and system transients. Chapter 1 gives an overview of the code's capabilities and limitations; Chapter 2 describes the code's structure, lists major subroutines, and discusses the computer requirements. Chapter 3 is on code, auxillary codes, and instructions for running RAMONA-4B on Sun SPARC and IBM Workstations. Chapter 4 contains component descriptions and detailed card-by-card input instructions. Chapter 5 provides samples of the tabulated output for the steady-state and transient calculations and discusses the plotting procedures for the steady-state and transient calculations. Three appendices contain important user and programmer information: lists of plot variables (Appendix A) listings of input deck for sample problem (Appendix B), and a description of the plotting program PAD (Appendix C). 24 refs., 18 figs., 11 tabs

  19. Polarimetric neutron scattering

    International Nuclear Information System (INIS)

    Tasset, F.

    2001-01-01

    Polarimetric Neutron Scattering in introduced, both by, explaining methodological issues and the corresponding instrumental developments. After a short overview of neutron spin polarization and the neutron polarization 3d-vector a pictorial approach of the microscopic theory is used to show how a polarized beam interacts with lattice and magnetic Fourier components in a crystal. Examples are given of using Spherical Neutron Polarimetry (SNP) and the corresponding Cryopad polarimeter for the investigation of non-collinear magnetic structures. (R.P.)

  20. Study of the {sup 17}O(n,α){sup 14}C reaction: Extension of the Trojan Horse Method to neutron induced reactions

    Energy Technology Data Exchange (ETDEWEB)

    Guardo, G. L.; Lamia, L.; Spitaleri, C.; Cherubini, S.; Rapisarda, G. G.; Sergi, M. L. [INFN - Laboratori Nazionali del Sud, Catania, Italy and Department of Physics and Astronomy, University of Catania, Catania (Italy); Gulino, M. [INFN - Laboratori Nazionali del Sud, Catania, Italy and University of Enna (Italy); Tang, X. D.; Bucher, B.; Couder, M.; Davies, P.; Boer, R. de; Fang, X.; Lamm, L.; Ma, C.; Notani, M.; OBrien, S.; Roberson, D.; Tan, W.; Wiescher, M. [Department of Physics and Joint Institute for Nuclear Astrophysics, University of Notre Dame, IN (United States); and others

    2014-05-02

    The experimental study of the {sup 17}O(n,α){sup 14}C reaction has been performed in the energy range 0-350 keV. This reaction could play an important role in explaining heavy elements (s-process) nucleosynthesis in various astrophysical scenario. To overcome the practical problems arising from the neutrons production, a new application of the Trojan Horse Method has been recently suggested. In more details, the {sup 17}O(n,α){sup 14}C reaction has been studied using the quasi-free {sup 2}H({sup 17}O,α{sup 14}C){sup 1}H reaction, induced at an energy of 43.5 MeV. The measurement allows one to investigate the ℓ=3, 75 keV resonance (E*=8.125 MeV, J{sup π}=5{sup −}), absent in the available direct measurements because of centrifugal suppression effects.

  1. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nuclearmalaysia.gov.my; Yussup, Nolida; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh Shaari, Syirrazie Bin Che; Azman, Azraf B. [Technical Support Division, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia); Salim, Nazaratul Ashifa Bt. Abdullah [Division of Waste and Environmental Technology, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia); Ismail, Nadiah Binti [Fakulti Kejuruteraan Elektrik, UiTM Pulau Pinang, 13500 Permatang Pauh, Pulau Pinang (Malaysia)

    2015-04-29

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  2. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    Science.gov (United States)

    Rahman, Nur Aira Abd; Yussup, Nolida; Salim, Nazaratul Ashifa Bt. Abdullah; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh@Shaari, Syirrazie Bin Che; Azman, Azraf B.; Ismail, Nadiah Binti

    2015-04-01

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on `Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)'. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  3. Neutron beam applications - Development of operational techniques for neutron four-circle diffractometer and structure determination of C{sub 16}H{sub 15}NO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moon Jib [Soonchunhyang University, Asan (Korea); Suh, Il Hwan [Chungnam National University, Taejon (Korea)

    1999-06-01

    We have been studied to find out the experimental methods and procedures for neutron diffraction method for neutron diffractometer in HANARO -the atomic research reactor in KAERI. We have studied experimental process for the neutron diffraction data analysis, using computer soft-wares such as SHELXS for the calculation the initial phase of crystal structure, SHELXL for refinement of atomic coordinate using least-squares method, ORTEP for the display of the calculated positions of molecule, and PATSEE for the calculation of the phase from the expected structure. In these studies, we analyzed the structure of test sample using these programs, and prepare the user's manual for these soft-wares. We have also studied on bending effect of monochromator in order to increase the intensity of neutron beam, and designed HRPD - High Resolution Powder Diffractometers. 7 refs., 6 figs. (Author)

  4. Reflectometry on D17

    Energy Technology Data Exchange (ETDEWEB)

    Cubitt, R [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    As part of the package of instrument upgrades planned over the next few years, D17 is based on a straightened cold neutron-guide and converted into a dedicated and versatile reflectometer. In the meantime, in order for ILL to become as fully involved as possible in this growing area of activity, the current D17 has been optimised for reflectometry. Results of this project are presented. (author).

  5. Radiography and tomography using fission neutrons at FRM-II

    International Nuclear Information System (INIS)

    Buecherl, T.; Lierse von Gostomski, Ch.

    2004-01-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm -2 s -1 for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  6. Radiography and tomography using fission neutrons at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T.; Lierse von Gostomski, Ch. [Inst. fuer Radiochemie, TU-Muenchen, Garching (Germany)

    2004-07-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm{sup -2} s{sup -1} for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  7. Platelet factor-4 and its p17-70 peptide inhibit myeloma proliferation and angiogenesis in vivo

    International Nuclear Information System (INIS)

    Yang, Longjiang; Du, Juan; Hou, Jian; Jiang, Hua; Zou, Jianfeng

    2011-01-01

    Angiogenesis plays an important role in the development of multiple myeloma (MM). The interaction between MM cells and the bone marrow microenvironment stimulates the proliferation and migration of endothelial progenitor cells (EPCs). Vascular endothelial growth factor (VEGF) contributes to the formation of new blood vessels by actively recruiting circulating EPCs. The production of proangiogenic and antiangiogenic factors is also dysregulated in MM. Platelet factor 4 (PF4) is a potent angiostatic cytokine that inhibits angiogenesis and tumor growth in several animal models. In this study, we stably transfected human myeloma cell lines with the PF4 gene or the sequence encoding its more potent p17-70 peptide and investigated the effects of PF4 and p17-70 on angiogenesis and tumor growth in vitro and in a SCID-rab myeloma model. PF4 and p17-70 significantly attenuated VEGF production, both in vitro and in vivo. In a migration study using a Transwell system, PF4 or p17-70 markedly suppressed the migration of co-cultured human endothelial progenitor cells. PF4 or p17-70 also caused a significant reduction in microvessel densities in myeloma xenografts and markedly reduced the tumor volume in the SCID mice. Kaplan-Meier analysis demonstrated that PF4 and p17-70 significantly extended the overall survival of SCID mice bearing human myeloma xenografts. Our findings indicate that PF4 or p17-70 could be valuable in combating multiple myeloma by disrupting tumor angiogenesis

  8. Measurement and analysis of double-differential neutron emission spectra in (P,N) and (α,N) reactions

    International Nuclear Information System (INIS)

    Okamoto, K.; Mehta, M.K.

    1988-05-01

    The second IAEA Research Co-ordination Meeting on Measurement and Analysis of Double-Differential Neutron Emission Spectra in (p,n) and (α,n) Reactions was convened by the IAEA Nuclear Data Section at the IAEA Headquarters in Vienna during 8-10 February, 1988. The main objectives of the Co-ordinated Research Project for which this meeting was held are (i) to extract systematic information about nuclear level densities as a function of excitation energy by analysing the neutron emission spectra from (p,n) and (α,n) reactions on properly selected targets and bombarding energy range, and (ii) to parametrize this information into appropriate phenomenological models to enable reliable extrapolation for general use of level density information in basic and applied nuclear physics related problems. Detailed conclusions and recommendations, together with a summary of the programme during 1988/1989 are attached in the Appendices

  9. Neutron Field Measurement of p(35)+Be Source using the Multi-foil Activation Method

    Czech Academy of Sciences Publication Activity Database

    Štefánik, Milan; Bém, Pavel; Majerle, Mitja; Novák, Jan; Šimečková, Eva; Štursa, Jan

    2017-01-01

    Roč. 2017, č. 11 (2017), č. článku 249. E-ISSN 1742-3406 Institutional support: RVO:61389005 Keywords : p+Be * Be target * neutron spectrum Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)

  10. Automation of angular movement of the arm neutron diffractometer

    International Nuclear Information System (INIS)

    Aguilar H, F.; Herrera A, E.; Quintana C, G.; Torres R, C. E.; Reyes V, M.

    2015-09-01

    A technique to determine the crystal structure of some materials is the neutron diffraction. This technique consists on placing the material in question in a monoenergetic neutron beam obtained by neutron diffraction in a monochromator crystal. The neutron energy depends of the diffraction angle. The Instituto Nacional de Investigaciones Nucleares has a neutron diffractometer and monochromator crystals of pyrolytic graphite. This crystal can be selecting the neutron energy depending on the angle of diffraction in the glass. The radiation source for the neutron diffractometer is the TRIGA Mark III reactor of the Nuclear Center Dr. Nabor Carrillo Flores. During their operation are also obtained besides neutrons, β and γ radiation. The interest is to have thermal neutrons, so fast neutrons and γ rays are removed using appropriate shielding. The average neutron fluxes of the radial port RE2 of neutron diffractometer at power 1 MW are: heat flow 2,466 x 10 8 n cm -2 sec -1 and fast flow 1,239 x 10 8 n cm -2 sec -1 . The neutron detector is housed in a shield mounted on a mechanical linkage with which the diffraction angle is selected, and therefore the energy of the neutrons. The movement of this joint was performed by the equipment operator manually, so that accuracy to select the diffraction angle was not good and the process rather slow. Therefore a mechanical system was designed, automated by means of a motor as an actuator, a system of force transmission and an electronic control in order that the operator will schedule the diffraction angles and allow the count in the neutrons detection system in a simple manner. (Author)

  11. Profile analysis of neutron powder diffraction data at ISIS

    International Nuclear Information System (INIS)

    David, W.I.F.; Ibberson, R.M.; Matthewman, J.C.

    1992-05-01

    The aim of this manual is to document the current suite of time-of-flight neutron powder diffraction profile refinement programs available to ISIS users. Aspects of data collation and normalisation specific to the individual diffraction instruments are dealt with elsewhere. It will be assumed the user has produced a suitable data file (.DAT file) containing the profile data consisting of point by point values of the corrected diffraction profile across the pattern. The analysis of neutron powder diffraction data at ISIS by profile refinement utilises a suite of ''in-house'' written and supported programs based on the Cambridge Crystallography Subroutine Library (CCSL). A quick scan through the CCSL manual will give the user a general feel for the procedure to adopt in the use of the library and hence of the profile codes. The instructions documented in this handbook are complementary to those in the more specialist CCSL manual, and consequently go into no great detail regarding technical details of any of the CCSL routines. The programs may be run from each individual user account, for example [USER01], once the appropriate login procedure has been set-up by the instrument scientists. The programs are mostly activated by one line commands and only a basic knowledge of a VAX editor should be required; details can be found in the ''VAX primer'' available from Computer Support. (Author)

  12. Radiosensitivity variations in human tumor cell lines exposed in vitro to p(66)/Be neutrons or 60Co γ-rays

    International Nuclear Information System (INIS)

    Slabbert, J.P.; Theron, T.; Serafin, A.; Jones, D.T.L.; Boehm, L.; Schmitt, G.

    1996-01-01

    Neutron therapy should be beneficial to patients with tumor types which are resistant to photons but relatively sensitive to high-LET radiation. In this work the potential therapeutic gain of a clinical neutron beam is evaluated by quantifying the variations in radiosensitivity of different cell lines to neutrons and photons. Different cell lines were exposed in vitro to p(66)/Be neutrons or 60 Co γ-rays. Micronuclei frequencies in binucleated cells and surviving fractions were determined for each cell type. Following exposure to either 1 or 1.5 Gy neutrons, micronuclei frequencies were significantly correlated with that observed for 2 Gy photons. A weak but significant correlation between the variation in neutron RBE values, determined from survival curve inactivation parameters and the mean inactivation doses for photon exposures, was also established. It is concluded that although neutron and photon sensitivities are related, the use of this high energy neutron source may constitute a potential therapeutic gain for tumor types that can be identified as very resistant to photons. Considering that a definitive oxygen gain factor has been established for this neutron beam the observed therapeutic gain is expected to be further enhanced in tumors where hypoxia protects cells from conventional radiation damage. (orig.) [de

  13. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  14. Optimization of a neutron production target based on the 7Li (p,n)7Be reaction with the Monte Carlo Method

    International Nuclear Information System (INIS)

    Burlon, Alejandro A.; Kreiner, Andres J.; Minsky, Daniel; Valda, Alejandro A.; Somacal, Hector R.

    2003-01-01

    In order to optimize a neutron production target for accelerator-based boron neutron capture therapy (AB-BNCT) a Monte Carlo Neutron and Photon (MCNP) investigation has been performed. Neutron fields from a LiF thick target (with both a D 2 O-graphite and a Al/AlF 3 -graphite moderator/reflector assembly) were evaluated along the centerline in a head phantom. The target neutron beam was simulated from the 7 Li(p,n) 7 Be nuclear reaction for 1.89, 2.0 and 2.3 MeV protons. The results show that it is more advantageous to irradiate the target with near resonance energy protons (2.3 MeV) because of the high neutron yield at this energy. On the other hand, the Al/AlF 3 -graphite exhibits a more efficient performance than D 2 O. (author)

  15. The Impact of MicroRNA-223-3p on IL-17 Receptor D Expression in Synovial Cells.

    Directory of Open Access Journals (Sweden)

    Nozomu Moriya

    Full Text Available Rheumatoid arthritis (RA is an autoimmune inflammatory disease affecting joints. Elevated plasma levels of microRNA-223-3p (miR-223-3p in patients with RA are implicated in the pathogenesis of the disease. This study aimed to analyze the functional role of miR-223-3p in the pathogenesis of RA by overexpressing miR-223-3p in synovial cell lines.Arthritis was induced in the RA model of SKG mice by injection of ß-glucan. The histopathologic features of joints were examined using hematoxylin and eosin and immunohistochemical staining. Plasma levels of miRNA were determined by panel real-time PCR analysis. Target genes of the differentially expressed miRNAs in SKG mice were analyzed using miRNA target prediction algorithms. The dual-luciferase reporter system was used to evaluate the relationship between miR-223-3p and IL-17 receptor D (IL-17RD. The activity of miR-223-3p was analyzed by transfection of plasmid vectors overexpressing miR-223-3p into IL-17RD-expressing NIH3T3 and MH7A cell lines. Il6 and Il17rd mRNA expression was analyzed by quantitative real-time PCR. IL-17RD protein expression was analyzed by western blot analysis.We identified 17 upregulated miRNAs (fold change > 2.0 in plasma of SKG mice injected with ß-glucan relative to untreated SKG mice. Il17rd was identified as the candidate target gene of miR-223-3p using five miRNA target prediction algorithms. The transfection of plasmid vectors overexpressing miR-223-3p into NIH3T3 and MH7A cells resulted in the downregulation of Il17rd expression and upregulation of Il6 expression. Expression of miR-223-3p and Il6 mRNA in MH7A cells was upregulated; however, that of Il17rd mRNA was downregulated following TNF-α stimulation. IL-17RD expression in synovial tissues from SKG mice and RA patients was inversely correlated with the severity of arthritis.This study is the first to demonstrate that miR-223-3p downregulates IL-17RD in both mouse and human cells; miR-223-3p may contribute to

  16. ALPHA/PHOENIX-P/ANC system validation for Angra-1 neutronic calculations

    International Nuclear Information System (INIS)

    Ponzoni Filho, Pedro; Sato, Sadakatu; Santos, Teresinha Ipojuca Cardoso; Fernandes, Vanderlei Borba; Fetterman, R.J.

    1995-01-01

    The ALPHA/PHOENIX-P/ANC (APA) code package is an advanced neutronic calculation system for pressurized water reactor (PWR). PHOENIX-P generates the required cross sections for the fuel, burnable absorbers, control rods and baffle/reflector region. The ALPHA code is used to automate the generation of these cross-sections as well as process the PHOENIX-P results to generate the ANC model input. ANC is a three dimensional advanced nodal code used for the modeling of the, depletion of the fuel in the core, and for the calculation of power distributions, rod worths and other reactivity parameters. This paper provides brief overview of the APA methodology for reload core design of Angra Unit 1 Cycles 1 and 2. Results included are predicted power distributions, control rod worths and other reactivity parameters compared to plant measurements. These results demonstrate that the APA system can be used for the reload core design. (author). 7 refs, 9 figs

  17. ALPHA/PHOENIX-P/ANC system validation for Angra-1 neutronic calculations

    Energy Technology Data Exchange (ETDEWEB)

    Ponzoni Filho, Pedro; Sato, Sadakatu; Santos, Teresinha Ipojuca Cardoso; Fernandes, Vanderlei Borba [FURNAS, Rio de Janeiro, RJ (Brazil); Fetterman, R.J. [Westinghouse Electric Corp., Pittsburgh, PA (United States)

    1995-12-31

    The ALPHA/PHOENIX-P/ANC (APA) code package is an advanced neutronic calculation system for pressurized water reactor (PWR). PHOENIX-P generates the required cross sections for the fuel, burnable absorbers, control rods and baffle/reflector region. The ALPHA code is used to automate the generation of these cross-sections as well as process the PHOENIX-P results to generate the ANC model input. ANC is a three dimensional advanced nodal code used for the modeling of the, depletion of the fuel in the core, and for the calculation of power distributions, rod worths and other reactivity parameters. This paper provides brief overview of the APA methodology for reload core design of Angra Unit 1 Cycles 1 and 2. Results included are predicted power distributions, control rod worths and other reactivity parameters compared to plant measurements. These results demonstrate that the APA system can be used for the reload core design. (author). 7 refs, 9 figs.

  18. Avian Reovirus Protein p17 Functions as a Nucleoporin Tpr Suppressor Leading to Activation of p53, p21 and PTEN and Inactivation of PI3K/AKT/mTOR and ERK Signaling Pathways.

    Directory of Open Access Journals (Sweden)

    Wei-Ru Huang

    Full Text Available Avian reovirus (ARV protein p17 has been shown to regulate cell cycle and autophagy by activation of p53/PTEN pathway; nevertheless, it is still unclear how p53 and PTEN are activated by p17. Here, we report for the first time that p17 functions as a nucleoporin Tpr suppressor that leads to p53 nuclear accumulation and consequently activates p53, p21, and PTEN. The nuclear localization signal (119IAAKRGRQLD128 of p17 has been identified for Tpr binding. This study has shown that Tpr suppression occurs by p17 interacting with Tpr and by reducing the transcription level of Tpr, which together inhibit Tpr function. In addition to upregulation of PTEN by activation of p53 pathway, this study also suggests that ARV protein p17 acts as a positive regulator of PTEN. ARV p17 stabilizes PTEN by stimulating phosphorylation of cytoplasmic PTEN and by elevating Rak-PTEN association to prevent it from E3 ligase NEDD4-1 targeting. To activate PTEN, p17 is able to promote β-arrestin-mediated PTEN translocation from the cytoplasm to the plasma membrane via a Rock-1-dependent manner. The accumulation of p53 in the nucleus induces the PTEN- and p21-mediated downregulation of cyclin D1 and CDK4. Furthermore, Tpr and CDK4 knockdown increased virus production in contrast to depletion of p53, PTEN, and LC3 reducing virus yield. Taken together, our data suggest that p17-mediated Tpr suppression positively regulates p53, PTEN, and p21 and negatively regulates PI3K/AKT/mTOR and ERK signaling pathways, both of which are beneficial for virus replication.

  19. Precise measurements of the thick target neutron yields of the {sup 7}Li(p,n) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Matysiak, W., E-mail: matysiw@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ont., L8S 4K1 (Canada); Prestwich, W.V.; Byun, S.H. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ont., L8S 4K1 (Canada)

    2011-07-01

    Thick target neutron yield of the {sup 7}Li(p,n){sup 7}Be reaction was measured in the proton energy range from 1.95 to 2.3 MeV by determining induced activity of the {sup 7}Be. A HPGe detector was used to detect the 478 keV gamma-rays emitted through {sup 7}Be decay. A series of irradiations with nominal proton energies of 1.95, 2.0, 2.1, 2.2, and 2.3 MeV were carried out. In an independent experiment, raw neutron spectra were collected by a {sup 3}He ion chamber for the same series of proton energies. From the raw neutron spectra, it was noted, that the effective proton energies were lower than the nominal by 50-58 keV. After corrections for the proton energy offsets were applied, the measured neutron yields matched the analytically calculated yields within 20%. Long term stability of neutron yield was tested at two nominal proton energies, 2.1 and 1.95 MeV over an experimental period of one year. The results show that the yield at 2.1 MeV was stable within rmse variation coefficient of 4.7% and remained consistent even when the lithium target was replaced, whereas at 1.95 MeV, the maximum fluctuations reached a factor of 10.

  20. Radiochemical study of 45Sc(n,p)45Ca and 89Y(n,p)89Sr reactions in the neutron energy range of 13.9 to 14.7 MeV

    International Nuclear Information System (INIS)

    Molla, N.I.; Basunia, S.; Miah, M.R.; Hossain, S.M.; Rahman, M.M.; Spellerberg, S.; Qaim, S.M.

    1998-01-01

    Cross sections for 45 Sc(n,p) 45 Ca and 89 Y(n,p) 89 Sr reactions were measured using the activation technique. Monoenergetic neutrons in the energy range of 13.9 to 14.7 MeV were produced using a D-T neutron generator. The purely β - emitting products 45 Ca and 89 Sr were separated radiochemically; their radioactivity was assayed via low-level β - counting. The measured data complement the available published experimental information, and agree with the results of statistical model calculations. (orig.)

  1. Energy spectra of neutrons accompanying the emission fission of 238U

    International Nuclear Information System (INIS)

    Smirenkin, G.N.; Lovchikova, G.N.; Trufanov, A.M.; Svirin, M.I.; Polyakov, A.V.; Vinogradov, V.A.; Dmitriev, V.D.; Boykov, G.S.

    1996-01-01

    The spectra of fission neutrons emitted from 238U are measured for the first time by the time-of-flight method at incident-neutron energies of 16.0 and 17.7 MeV. Analysis of the neutron spectra shows that experimental results at incident-neutron energies of 14.7, 16.0, and 17.7 MeV (above the threshold of chance fission) differ significantly from those obtained at a neutron energy of 2.9 MeV (below the threshold of chance fission). Owing to the prefission emission of neutrons, the observed spectra of neutrons from emission fission exhibit a characteristic growth of the neutron yield in both hard and soft sections of the spectrum of secondary neutrons. This growth manifests itself as a step in the first case and as a rise in the second case, where it results in a noticeable excess of neutrons over the statistical-model predictions for E<2 MeV. The first feature in the spectra of neutrons from emission fission can be associated with the nonequilibrium decay of an excited fissile nucleus. On the contrary, the origin of the second feature has yet to be clarified. Additional measurements of angular distributions of secondary neutrons may prove helpful in this respect

  2. Detailed design of neutron guide tubes at the upgraded JRR-3, (1)

    International Nuclear Information System (INIS)

    Harami, Taikan; Umemura, Mutsumi; Ebisawa, Tohru.

    1985-07-01

    JRR-3, currently a heavy water moderated and cooled 10 MW reactor, is to be upgraded to a light water moderated and cooled, heavy water reflected 20 MW reactor. Two guide tubes for thermal neutron and three for cold will be installed in the reactor to transport thermal and cold neutrons from the reactor hall to the experiment hall. This describes the neutron guide tube transmission analysis program, NEUGT, which was developed to assess the design of the neutron guide tubes. The input data plotting program, PLOPINE and the output data plotting program, NEUPLOT are presented in the appendix. The NEUGT program not only calculates a neutron transmission and neutron spectra, assuming the Maxwellian spectra at the entrance of a guide tube, but also analyses the effect of abutment errors. This reports the description and the input data manual of the program in the text. Examples of analysis are given in the appendixes. The program is written in the FORTRAN 77 language for FACOM 380. (author)

  3. Software-assisted quantitative analysis of small bowel motility compared to manual measurements

    International Nuclear Information System (INIS)

    Bickelhaupt, S.; Froehlich, J.M.; Cattin, R.; Raible, S.; Bouquet, H.; Bill, U.; Patak, M.A.

    2014-01-01

    Aim: To validate a newly developed software prototype that automatically analyses small bowel motility by comparing it directly with manual measurement. Material and methods: Forty-five patients with clinical indication for small bowel magnetic resonance imaging (MRI) were retrospectively included in this institutional review board-approved study. MRI was performed using a 1.5 T system following a standard MR-enterography protocol. Small bowel motility parameters (contractions-per-minute, luminal diameter, amplitude) were measured three times each in identical segments using the manual and the semiautomatic software-assisted method. The methods were compared for agreement, repeatability, and time needed for each measurement. All parameters were compared between the methods. Results: A total of 91 small-bowel segments were analysed. No significant intra-individual difference (p > 0.05) was found for peristaltic frequencies between the methods (mean: 4.14/min manual; 4.22/min software-assisted). Amplitudes (5.14 mm; 5.57 mm) and mean lumen diameters (17.39 mm; 14.68) differed due to systematic differences in the definition of the bowel wall. Mean duration of single measurement was significantly (p < 0.01) shorter with the software (6.25 min; 1.30 min). The scattering of repeated measurements was significantly (p < 0.05) lower using the software. Conclusion: The software-assisted method accomplished highly reliable, fast and accurate measurement of small bowel motility. Measurement precision and duration differed significantly between the two methods in favour of the software-assisted technique

  4. Experimental study of the $^{66}$Ni$(d,p)^{67}$Ni one-neutron transfer reaction

    CERN Document Server

    Diriken, J.; Andreyev, A.N.; Antalic, S.; Bildstein, V.; Blazhev, A.; Darby, I.G.; De Witte, H.; Eberth, J.; Elseviers, J.; Fedosseev, V.N.; Flavigny, F.; Fransen, Ch.; Georgiev, G.; Gernhauser, R.; Hess, H.; Huyse, M.; Jolie, J.; Kröll, Th.; Krücken, R.; Lutter, R.; Marsh, B.A.; Mertzimekis, T.; Muecher, D.; Orlandi, R.; Pakou, A.; Raabe, R.; Randisi, G.; Reiter, P.; Roger, T.; Seidlitz, M.; Seliverstov, M.; Sotty, C.; Tornqvist, H.; Van De Walle, J.; Van Duppen, P.; Voulot, D.; Warr, N.; Wenander, F.; Wimmer, K.

    2015-01-01

    The quasi-SU(3) sequence of the positive parity $νg_{9/2}, d_{5/2}, s_{1/2}$ orbitals above the N=40 shell gap are assumed to induce strong quadrupole collectivity in the neutron-rich Fe (Z=26) and Cr (Z=24) isotopes below the nickel region. In this paper the position and strength of these single-particle orbitals are characterized in the neighborhood of $^{68}$Ni (Z=28,N=40) through the $^{66}$Ni($d,p$)$^{67}$Ni one-neutron transfer reaction at 2.95 MeV/nucleon in inverse kinematics, performed at the REX-ISOLDE facility in CERN. A combination of the Miniball $\\gamma$-array and T-REX particle-detection setup was used and a delayed coincidence technique was employed to investigate the 13.3-$\\mu$s isomer at 1007 keV in $^{67}$Ni. Excited states up to an excitation energy of 5.8 MeV have been populated. Feeding of the $νg_{9/2}$ (1007 keV) and $νd_{5/2}$ (2207 keV and 3277 keV) positive-parity neutron states and negative parity ($νpf$) states have been observed at low excitation energy. The extracted relativ...

  5. Automatic control unit for neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Ashry, A.; Mostafa, M.; Hamouda, I. (Atomic Energy Establishment, Inshas (Egypt). Reactor and Neutron Physics Dept.)

    1981-01-01

    An automatic transistorized unit has been designed to control the neutron transmission measurements carried out using the time-of-flight spectrometer. The function of the automatic unit is to control the measurements of the neutron counting rate distribution transmitted through a sample at a selected channel group of the time analyzer for a certain preadjusted time period. At the end of this time, the unit removes the sample out of the neutron beam, selects a second equal channel group of the time analyzer and provides the measurement of the neutron counting rate distribution for the same time period as in the case with the sample on. Such a measuring cycle can be repeated as much as the experiment requires. At the end of these cycles the stored information can be immediately obtained through the analyzer read out unit. It is found that the time of removing the sample out of the neutron beam or returning it back does not exceed 20 seconds instead of the five minutes required in case of manual operation. The most important advantages of using such an automatic unit are saving about 20 percent of the reactor operating time avoidng unnecessary radiation exposure of the experimentalists.

  6. Manual on laboratory testing for uranium ore processing

    International Nuclear Information System (INIS)

    1990-01-01

    Laboratory testing of uranium ores is an essential step in the economic evaluation of uranium occurrences and in the development of a project for the production of uranium concentrates. Although these tests represent only a small proportion of the total cost of a project, their proper planning, execution and interpretation are of crucial importance. The main purposes of this manual are to discuss the objectives of metallurgical laboratory ore testing, to show the specific role of these tests in the development of a project, and to provide practical instructions for performing the tests and for interpreting their results. Guidelines on the design of a metallurgical laboratory, on the equipment required to perform the tests and on laboratory safety are also given. This manual is part of a series of Technical Reports on uranium ore processing being prepared by the IAEA's Division of Nuclear Fuel Cycle and Waste Management. A report on the Significance of Mineralogy in the Development of Flowsheets for Processing Uranium Ores (Technical Reports Series No. 196, 1980) and an instruction manual on Methods for the Estimation of Uranium Ore Reserves (No. 255, 1985) have already been published. 17 refs, 40 figs, 17 tabs

  7. Characterizing Neutron Diagnostics on the nTOF Line at SUNY Geneseo

    Science.gov (United States)

    Harrison, Hannah; Seppala, Hannah; Visca, Hannah; Wakwella, Praveen; Fletcher, Kurt; Padalino, Stephen; Forrest, Chad; Regan, Sean; Sangster, Craig

    2016-10-01

    Charged particle beams from SUNY Geneseo's 1.7 MV Tandem Pelletron Accelerator induce nuclear reactions that emit neutrons ranging from 0.5 to 17.9 MeV via 2H(d,n)3He and 11B(d,n)12C. This adjustable neutron source can be used to calibrate ICF and HEDP neutron scintillators for ICF diagnostics. However, gamma rays and muons, which are often present during an accelerator-based calibration, are difficult to differentiate from neutron signals in scintillators. To mitigate this problem, a new neutron time-of-flight (nTOF) line has been constructed. The nTOF timing is measured using the associated particle technique. A charged particle produced by the nuclear reaction serves as a start signal, while its associated neutron is the stop signal. Each reaction is analyzed event-by-event to determine whether the scintillator signal was generated by a neutron, gamma or muon. Using this nTOF technique, the neutron response for different scintillation detectors can be determined. Funded in part by a LLE contract through the DOE.

  8. Super-Eddington accretion on to the neutron star NGC 7793 P13: Broad-band X-ray spectroscopy and ultraluminous X-ray sources

    Science.gov (United States)

    Walton, D. J.; Fürst, F.; Harrison, F. A.; Stern, D.; Bachetti, M.; Barret, D.; Brightman, M.; Fabian, A. C.; Middleton, M. J.; Ptak, A.; Tao, L.

    2018-02-01

    We present a detailed, broad-band X-ray spectral analysis of the ultraluminous X-ray source (ULX) pulsar NGC 7793 P13, a known super-Eddington source, utilizing data from the XMM-Newton, NuSTAR and Chandra observatories. The broad-band XMM-Newton+NuSTAR spectrum of P13 is qualitatively similar to the rest of the ULX sample with broad-band coverage, suggesting that additional ULXs in the known population may host neutron star accretors. Through time-averaged, phase-resolved and multi-epoch studies, we find that two non-pulsed thermal blackbody components with temperatures ∼0.5 and 1.5 keV are required to fit the data below 10 keV, in addition to a third continuum component which extends to higher energies and is associated with the pulsed emission from the accretion column. The characteristic radii of the thermal components appear to be comparable, and are too large to be associated with the neutron star itself, so the need for two components likely indicates the accretion flow outside the magnetosphere is complex. We suggest a scenario in which the thick inner disc expected for super-Eddington accretion begins to form, but is terminated by the neutron star's magnetic field soon after its onset, implying a limit of B ≲ 6 × 1012 G for the dipolar component of the central neutron star's magnetic field. Evidence of similar termination of the disc in other sources may offer a further means of identifying additional neutron star ULXs. Finally, we examine the spectrum exhibited by P13 during one of its unusual 'off' states. These data require both a hard power-law component, suggesting residual accretion on to the neutron star, and emission from a thermal plasma, which we argue is likely associated with the P13 system.

  9. Characterization of proton and neutron irradiated low resistivity p-on-n magnetic Czochralski ministrip sensors and diodes

    International Nuclear Information System (INIS)

    Pacifico, Nicola; Dolenc Kittelmann, Irena; Fahrer, Manuel; Moll, Michael; Militaru, Otilia

    2011-01-01

    Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements were performed on low resistivity (280Ωcm) n-bulk, p-readout magnetic Czochralski ministrip sensors and diodes. The detectors were irradiated with neutrons and 24 GeV/c protons up to a total NIEL equivalent fluence of 8×10 15 /cm 2 . The study was addressed to assess the radiation tolerance of the detectors up to fluences expected in the next generations of High Energy Physics experiments. The charge collection efficiency after irradiation was found to be much higher than for standard FZ silicon p-in-n sensors. The underlying physics of this remarkable result was investigated by performing Edge-TCT measurements on one of the neutron irradiated ministrip sensors to extract detailed informations about the field and efficiency profiles of the detector.

  10. Nuclear data needed for neutron therapy

    International Nuclear Information System (INIS)

    Okamoto, K.

    1988-03-01

    This is the summary report of the First Research Co-ordination Meeting of the IAEA Co-ordinated Research Programme (CRP) on Nuclear Data Needed for Neutron Therapy, convened by the IAEA Nuclear Data Section in Vienna, from 17 to 20 November 1987. The main objectives of the CRP are to improve the present state of nuclear data for neutron therapy. (author)

  11. POW3D-Neutron diffusion module of the AUS system. A user's manual

    International Nuclear Information System (INIS)

    Harrington, B.V.; Pollard, J.P.; Barry, J.M.

    1996-11-01

    POW3D is a three-dimensional neutron diffusion module of the AUS modular neutronics code system. It performs eigenvalue, source of feedback-free kinetics calculations. The module includes general criticality search options and extensive editing facilities including perturbation calculations. Output options include flux or reaction rate plot files. The code permits selection from one of a variety of different solution methods (MINI, ICCG or SLOR) for inner iterations with region re balance to enhance convergence. A MINI accelerated Gauss-Siedel method is used for upscatter iterations with group rebalance to enhance a convergence. Chebyshev source extrapolation is applied for outer iterations. A detailed index is included

  12. Features of the neutron spectra accompanying the fission of actinide nuclei

    International Nuclear Information System (INIS)

    Lovchikova, G.N.; Trufanov, A.M.; Svirin, M.I.; Polyakov, A.V.; Vinogradov, V.A.; Dmitriev, V.D.; Boykov, G.S.

    2000-01-01

    The spectra of fission neutrons from 238 U are measured by the time-of-flight technique at incident-neutron energies E n = 5.0 and 13.2 MeV. The data are compared with those obtained in the previous studies for 232 Th, 235,238 U, 237 Np at E n = 2.9 and 14.7 MeV; for 232 Th at E n = 14.6 and 17.7 MeV; for 238 U at 16.0 and 17.7 MeV. An excess of soft neutrons, which is observed in comparing experimental spectra for E n 13.2, 14.7, 16.0 and 17.7 MeV with the results of traditional theoretical calculations, is reproduced fairly well under the assumption that, at high excitation energies of a compound system, some part of post-fission neutrons can be emitted by nonaccelerated fragments [ru

  13. A practical contribution to the dosimetry of fast neutrons in radio-protection - determination of the integrated dose in man using the {sup 32}S(n, p){sup 32}P reaction (1963); Contribution pratique a la dosimetrie des neutrons rapides en radioprotection - determination de la dose integree par reaction {sup 32}S(n, p){sup 32}P chez l'homme (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Scheidhauer, J; Chabidon, M [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1963-07-01

    The problem of fast neutron dosimetry using activation is studied from the radio-protection point of view. The practical development of methods for analyzing phosphorus 32 produced by the activation of sulphur 32 in human hair by the reaction {sup 32}S(n, p){sup 32}P is described. The sensitivity obtained is 5 rad. A preliminary study was made of the variations in the natural sulphur and phosphorus concentrations. (authors) [French] Le probleme de la dosimetrie des neutrons rapides par activation est etudie sous l'angle de la radioprotectlon. Une mise au point pratique de methodes d'analyae du phosphore 32 induit par activation du soufre 32 des cheveux humains par reaction {sup 32}S(n, p){sup 32}P est exposee. La sensibilite obtenue est de 5 rad. Les variations du soufre et du phosphore naturels ont fait l'objet d'une etude preliminaire. (auteurs)

  14. Neutron spectroscopy, nuclear structure, related topics. Abstracts

    International Nuclear Information System (INIS)

    Sukhovoj, A.M.

    1996-01-01

    Neutron spectroscopy, nuclear structure and related topics are considered. P, T-breaking, neutron beta decay, neutron radiative capture and neutron polarizability are discussed. Reaction with fast neutrons, methodical aspect low-energy fission are considered too

  15. Measurements of activation cross-sections for the 101Ru(n,p)101Tc reaction for neutrons with energies between 13 and 15 MeV

    International Nuclear Information System (INIS)

    Junhua Luo; Peking University, Beijing; Jiuning Han; Suhong Ge; Zhenlai Liu; Guihua Sun; Rong Liu; Li Jiang

    2013-01-01

    In this study, activation cross-sections were measured for the 101 Ru(n,p) 101 Tc reaction at three different neutron energies from 13.5 to 14.8 MeV. The fast neutrons were produced via the 3 H(d,n) 4 He reaction on K-400 neutron generator. Induced gamma activities were measured by a high-resolution gamma-ray spectrometer with high-purity germanium detector. Measurements were corrected for gamma-ray attenuations, random coincidence (pile-up), dead time and fluctuation of neutron flux. The data for 101 Ru(n,p) 101 Tc reaction cross-sections are reported to be 15.7 ± 2.0, 18.4 ± 2.7 and 22.0 ± 2.4 mb at 13.5 ± 0.2, 14.1 ± 0.2, and 14.8 ± 0.2 MeV incident neutron energies, respectively. Results were compared with the previous works. (author)

  16. Neutron polarization

    International Nuclear Information System (INIS)

    Firk, F.W.K.

    1976-01-01

    Some recent experiments involving polarized neutrons are discussed; they demonstrate how polarization studies provide information on fundamental aspects of nuclear structure that cannot be obtained from more traditional neutron studies. Until recently, neutron polarization studies tended to be limited either to very low energies or to restricted regions at higher energies, determined by the kinematics of favorable (p, vector n) and (d, vector n) reactions. With the advent of high intensity pulsed electron and proton accelerators and of beams of vector polarized deuterons, this is no longer the case. One has entered an era in which neutron polarization experiments are now being carried out, in a routine way, throughout the entire range from thermal energies to tens-of-MeV. The significance of neutron polarization studies is illustrated in discussions of a wide variety of experiments that include the measurement of T-invariance in the β-decay of polarized neutrons, a search for the effects of meson exchange currents in the photo-disintegration of the deuteron, the determination of quantum numbers of states in the fission of aligned 235 U and 237 Np induced by polarized neutrons, and the double- and triple-scattering of fast neutrons by light nuclei

  17. Polarized Epithermal Neutron Studies of Magnetic Domains

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Chernikov, A.N.; Lason, L.; Mareev, Yu. D.; Novitsky, V.V.; Pikelner, L.B.; Skoy, V.R.; Tsulaya, M.I.; Gould, C.R.; Haase, D.G.; Roberson, N.R.

    1997-01-01

    The average size and shape of magnetic domains in a material can be determined from the precession of polarized neutrons traversing the material. Epithermal neutrons (0.5eV< En<100eV), which process more slowly than thermals, effectively probe the internal structure of samples that are thick or have large domains or large internal fields. Such epithermal neutron measurements require a neutron polarizer and analyzer based on cryogenically polarized spin filters. We discuss the measurements at JINR, Dubna, of magnetic domains in a 2.0 cm. diam. crystal of holmium using 1.7 to 59eV neutrons polarized by a dynamically polarized proton target and analyzed with a statically polarized dysprosium target

  18. Neutron fluence measurements

    International Nuclear Information System (INIS)

    1970-01-01

    For research reactor work dealing with such subjects as radiation effects on solids and such disciplines as radiochemistry and radiobiology, the radiation dose or neutron fluence is an essential parameter in evaluating results. Unfortunately it is very difficult to determine. Even when the measurements have been accurate, it is difficult to compare results obtained in different experiments because present methods do not always reflect the dependence of spectra or of different types of radiation on the induced processes. After considering the recommendations of three IAEA Panels, on 'In-pile dosimetry' held in July 1964, on 'Neutron fluence measurements' in October 1965, and on 'In-pile dosimetry' in November 1966, the Agency established a Working Group on Reactor Radiation Measurements. This group consisted of eleven experts from ten different Member States and two staff members of the Agency. In the measurement of energy absorbed by materials from neutrons and gamma rays, there are various reports and reviews scattered throughout the literature. The group, however, considered that the time was ripe for all relevant information to be evaluated and gathered together in the form of a practical guide, with the aim of promoting consistency in the measurement and reporting of reactor radiation. The group arranged for the material to be divided into two manuals, which are expected to be useful both for experienced workers and for beginners

  19. An accelerator-based Boron Neutron Capture Therapy (BNCT) facility based on the 7Li(p,n)7Be

    Science.gov (United States)

    Musacchio González, Elizabeth; Martín Hernández, Guido

    2017-09-01

    BNCT (Boron Neutron Capture Therapy) is a therapeutic modality used to irradiate tumors cells previously loaded with the stable isotope 10B, with thermal or epithermal neutrons. This technique is capable of delivering a high dose to the tumor cells while the healthy surrounding tissue receive a much lower dose depending on the 10B biodistribution. In this study, therapeutic gain and tumor dose per target power, as parameters to evaluate the treatment quality, were calculated. The common neutron-producing reaction 7Li(p,n)7Be for accelerator-based BNCT, having a reaction threshold of 1880.4 keV, was considered as the primary source of neutrons. Energies near the reaction threshold for deep-seated brain tumors were employed. These calculations were performed with the Monte Carlo N-Particle (MCNP) code. A simple but effective beam shaping assembly (BSA) was calculated producing a high therapeutic gain compared to previously proposed facilities with the same nuclear reaction.

  20. Measurement of the {sup 15}O(2p,{gamma}){sup 17}Ne cross section by Coulomb dissociation of {sup 17}Ne

    Energy Technology Data Exchange (ETDEWEB)

    Marganiec, Justyna [ExtreMe Matter Institute EMMI, GSI Darmstadt, Darmstadt (Germany); Aumann, Thomas; Heil, Michael; Plag, Ralf; Wamers, Felix [Kernreaktionen und Nuklear Astrophysik, GSI Darmstadt, Darmstadt (Germany)

    2010-07-01

    For the production of proton-rich nuclei during the rp process two-proton capture plays an important role. This process can bridge long-lived waiting points which otherwise hamper the mass flow between CNO material and the FeNi mass region. One of these waiting points is {sup 15}O. The three-body radiative capture can proceed sequentially or directly from the three-body continuum. The rate of the {sup 15}O(2p,{gamma}){sup 17}Ne reaction obtained using the two-successive-proton-capture model has been discussed in J. Goerres et al. (Phys. Rev. C 51, 392, 1995). The role of continuum states ({sup 15}O+2p) for the rate calculation has been demonstrated in L.V Grigorenko, M.V. Zhukov (Phys. Rev. C 72, 015803, 2005). It has been suggested that the reaction rate can be enhanced by a few orders of magnitude by taking into account the three-body continuum. In order to verify these calculations, we have deduced the {sup 15}O(2p,{gamma}){sup 17}Ne cross section by studying the time-reversed process, the Coulomb dissociation of {sup 17}Ne, at the LAND/R{sup 3}B setup at GSI, using a {sup 17}Ne secondary beam from the fragment separator FRS.

  1. Characterization of neutron flux spectra in the irradiation sites of a 37 GBq {sup 241}Am-Be isotopic source

    Energy Technology Data Exchange (ETDEWEB)

    Yücel, Haluk [Ankara University, Institute of Nuclear Sciences, 06100 Tandogan, Ankara (Turkey); Budak, Mustafa Guray, E-mail: mbudak@gazi.edu.tr [Gazi University, Gazi Education Faculty, 06500 Teknikokullar, Ankara (Turkey); Karadag, Mustafa [Gazi University, Gazi Education Faculty, 06500 Teknikokullar, Ankara (Turkey); Yüksel, Alptuğ Özer [Ankara University, Institute of Nuclear Sciences, 06100 Tandogan, Ankara (Turkey)

    2014-11-01

    Highlights: • An irradiation unit was installed using a 37 GBq {sup 241}Am-Be neutron source. • The source neutrons moderated by using both water and paraffin. • Irradiation unit was shielded by boron oxide and lead against neutrons and gammas. • There are two sites for irradiations, one of them has a pneumatic transfer system. • Cadmium ratio method was used for irradiation site characterization. - Abstract: For the applicability of instrumental neutron activation analysis (NAA) technique, an irradiation unit with a 37 GBq {sup 241}Am-Be neutron source was installed at Institute of Nuclear Sciences of Ankara University. Design and configuration properties of the irradiation unit are described. It has two different sample irradiation positions, one is called site #1 having a pneumatic sample transfer system and the other is site #2 having a location for manual use. In order to characterize neutron flux spectra in the irradiation sites, the measurement results were obtained for thermal (φ{sub th}) and epithermal neutron fluxes (φ{sub epi}), thermal to epithermal flux ratio (f) and epithermal spectrum shaping factors (α) by employing cadmium ratios of gold (Au) and molybdenum (Mo) monitors. The activities produced in these foils were measured by using a p-type, 44.8% relative efficiency HPGe well detector. For the measured γ-rays, self-absorption and true coincidence summing effects were taken into account. Additionally, thermal neutron self-shielding and resonance neutron self-shielding effects were taken into account in the measured results. For characterization of site #1, the required parameters were found to be φ{sub th} = (2.11 ± 0.05) × 10{sup 3} n cm{sup −2} s{sup −1}, φ{sub epi} = (3.32 ± 0.17) × 10{sup 1} n cm{sup −2} s{sup −1}, f = 63.6 ± 1.5, α = 0.045 ± 0.009, respectively. Similarly, those parameters were measured in site #2 as φ{sub th} = (1.49 ± 0.04) × 10{sup 3} n cm{sup −2} s{sup −1}, φ{sub epi} = (2.93 ± 0

  2. Thermal Neutron Die-Way-Time Studies for P and DGNAA of Radioactive Waste Drums at the MEDINA Facility

    Energy Technology Data Exchange (ETDEWEB)

    Mildenberger, Frank; Mauerhofer, Eric [Institute of Energy and Climate Research - Nuclear Waste Management and Reactor Safety, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany)

    2015-07-01

    In Germany, radioactive waste with negligible heat production has to pass through a process of quality checking in order to check its conformance with national regulations prior to its transport, intermediate storage and final disposal. Additionally to its radioactive components, the waste may contain non-radioactive chemically toxic substances that can adversely affect human health and pollute the environment, especially the ground water. After an adequate decay time, the waste radioactivity will become harmless but the non-radioactive substances will persist over time. In principle, these hazardous substances may be quantified from traceability and quality controls performed during the production of the waste packages. As a consequence, a research and development program was initiated in 2007 with the aim to develop a nondestructive analytical technique for radioactive waste packages based on prompt and delayed gamma neutron activation analysis (P and DGNAA) employing a DT-neutron generator in pulsed mode. In a preliminary study it was experimentally demonstrated that P and DGNAA is suitable to determine the chemical composition of large samples. In 2010 a facility called MEDINA (Multi Element Detection based on Instrumental Neutron Activation) was developed for the qualitative and quantitative determination of nonradioactive, toxic elements and substances in 200-l steel drums. The determination of hazardous substances and elements is generally achieved measuring the prompt gamma-rays induced by thermal neutrons. Additional information about the composition of the waste matrix could be derived measuring the delayed gamma-rays from short life activation products. However a sensitive detection of these delayed gamma-rays requires that thermal neutrons have almost vanished. Therefore, the thermal neutron die-away-time has to be known in order to achieve an optimal discrimination between prompt and delayed gamma-ray spectra acquisition. Measurements Thermal neutron

  3. An instability due to the nonlinear coupling of p-modes to g-modes: Implications for coalescing neutron star binaries

    International Nuclear Information System (INIS)

    Weinberg, Nevin N.; Arras, Phil; Burkart, Joshua

    2013-01-01

    A weakly nonlinear fluid wave propagating within a star can be unstable to three-wave interactions. The resonant parametric instability is a well-known form of three-wave interaction in which a primary wave of frequency ω a excites a pair of secondary waves of frequency ω b + ω c ≅ ω a . Here we consider a nonresonant form of three-wave interaction in which a low-frequency primary wave excites a high-frequency p-mode and a low-frequency g-mode such that ω b + ω c >> ω a . We show that a p-mode can couple so strongly to a g-mode of similar radial wavelength that this type of nonresonant interaction is unstable even if the primary wave amplitude is small. As an application, we analyze the stability of the tide in coalescing neutron star binaries to p-g mode coupling. We find that the equilibrium tide and dynamical tide are both p-g unstable at gravitational wave frequencies f gw ≳ 20 Hz and drive short wavelength p-g mode pairs to significant energies on very short timescales (much less than the orbital decay time due to gravitational radiation). Resonant parametric coupling to the tide is, by contrast, either stable or drives modes at a much smaller rate. We do not solve for the saturation of the p-g instability and therefore we cannot say precisely how it influences the evolution of neutron star binaries. However, we show that if even a single daughter mode saturates near its wave breaking amplitude, the p-g instability of the equilibrium tide will (1) induce significant orbital phase errors (Δφ ≳ 1 radian) that accumulate primarily at low frequencies (f gw ≲ 50 Hz) and (2) heat the neutron star core to a temperature of T ∼ 10 10 K. Since there are at least ∼100 unstable p-g daughter pairs, Δφ and T are potentially much larger than these values. Tides might therefore significantly influence the gravitational wave signal and electromagnetic emission from coalescing neutron star binaries at much larger orbital separations than previously

  4. Waterproofing with polymeric geo synthetic barriers (GBR-P) in the manual for the design, construction, management and maintenance of reservoirs

    International Nuclear Information System (INIS)

    Blanco, M.; Cea, J. C.; Garcia, F.; Sanchez, F. J.; Castillo, F.; Mora, J.; Crespo, M. A.

    2010-01-01

    This article presents a part of Manual for the Design, Construction, Management and Maintenance of Reservoirs relative to waterproofing with Polymeric Geo synthetic Barriers (GBR-P). the nature materials of geo membranes is studied also theirs characteristics and specifications. (Author) 26 refs.

  5. RAMONA-4B a computer code with three-dimensional neutron kinetics for BWR and SBWR system transient - user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Rohatgi, U.S.; Cheng, H.S.; Khan, H.J.; Mallen, A.N.; Neymotin, L.Y.

    1998-03-01

    This document is the User`s Manual for the Boiling Water Reactor (BWR), and Simplified Boiling Water Reactor (SBWR) systems transient code RAMONA-4B. The code uses a three-dimensional neutron-kinetics model coupled with a multichannel, nonequilibrium, drift-flux, phase-flow model of the thermal hydraulics of the reactor vessel. The code is designed to analyze a wide spectrum of BWR core and system transients. Chapter 1 gives an overview of the code`s capabilities and limitations; Chapter 2 describes the code`s structure, lists major subroutines, and discusses the computer requirements. Chapter 3 is on code, auxillary codes, and instructions for running RAMONA-4B on Sun SPARC and IBM Workstations. Chapter 4 contains component descriptions and detailed card-by-card input instructions. Chapter 5 provides samples of the tabulated output for the steady-state and transient calculations and discusses the plotting procedures for the steady-state and transient calculations. Three appendices contain important user and programmer information: lists of plot variables (Appendix A) listings of input deck for sample problem (Appendix B), and a description of the plotting program PAD (Appendix C). 24 refs., 18 figs., 11 tabs.

  6. RPL-SC dosimetric system for measuring gamma and neutron irradiation in case of emergency

    International Nuclear Information System (INIS)

    Khristova, M. G.

    1993-01-01

    A RPL-SC dosimetric system is designed based on radiophotoluminescence (RPL) and on the effect of fast neutron bombardment of silicon semiconductor (SC) diodes. The experimental prototype consists of a computerized automatic measurement system and an individual dosimetric cassette accommodating RPL and SC detectors. The equipment includes: a device for measurement of the direct voltage of Si diodes and the RPL light emitted by RPL detectors; a compartment with dosimetric cassettes to be measured; a manipulator with three positions executing automatic measurement of cassettes; a computer and a printer. The system operates in both manual and automatic modes. In the manual mode each step of the manipulator is set up by the operator who changes the ranges after they have been filled to capacity and registers the results. In the automatic mode the whole process of maintaining the supply and control voltage, of manipulator's operation, measuring, data recording and data processing are controlled by a specially designed computer programme. Main technical parameters: 1) Measurement range of absorbed dose: gamma rays - 10 -3 to 10 2 Gy; thermal neutrons - 10 -3 to 10 2 Gy; fast neutrons - 10 to 30 Gy. 2) Energy range: gamma rays - 0.04 to 1.25 MeV; thermal neutrons - 0.024 eV; fast neutrons - 0.3 to 14 MeV. 3) Relative measurement error - ±15% 4) Recurrent measurement of one and the same dose. 5) Measurement time of 1 detector - 15 sec. (author)

  7. Neutron activation analysis of geochemical samples

    International Nuclear Information System (INIS)

    Rosenberg, R.; Zilliacus, R.; Kaistila, M.

    1983-06-01

    The present paper will describe the work done at the Technical Research Centre of Finland in developing methods for the large-scale activation analysis of samples for the geochemical prospecting of metals. The geochemical prospecting for uranium started in Finland in 1974 and consequently a manually operated device for the delayed neutron activation analysis of uranium was taken into use. During 1974 9000 samples were analyzed. The small capacity of the analyzer made it necessary to develop a completely automated analyzer which was taken into use in August 1975. Since then 20000-30000 samples have been analyzed annually the annual capacity being about 60000 samples when running seven hours per day. Multielemental instrumental neutron activation analysis is used for the analysis of more than 40 elements. Using instrumental epithermal neutron activation analysis 25-27 elements can be analyzed using one irradiation and 20 min measurement. During 1982 12000 samples were analyzed for mining companies and Geological Survey of Finland. The capacity is 600 samples per week. Besides these two analytical methods the analysis of lanthanoids is an important part of the work. 11 lanthanoids have been analyzed using instrumental neutron activation analysis. Radiochemical separation methods have been developed for several elements to improve the sensitivity of the analysis

  8. Anisotropy of neutron sources of Neutron Metrology Laboratory, IRD, Brazil; Anisotropia de fontes de neutrons do Laboratorio de Metrologia de Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A.C.F.; Silva, F.S.; Leite, S.P.; Creazolla, P.G; Patrão, K.C.S.; Fonseca, E.S. da; Fernandes, S.S.; Pereira, W.W., E-mail: Alexander.camargo@oi.com.br, E-mail: s.felippesouza@gmail.com, E-mail: karla@ird.gov.br, E-mail: walsan@ird.gov.br, E-mail: evaldo@ird.gov.br, E-mail: simonesilvafernandes@gmail.com, E-mail: prycyllacreazolla@gmail.com, E-mail: leitesprk@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Laboratorio Nacional de Metrologia; Fundação Técnico Educacional Souza Marques (FTESM), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    The anisotropy measurements have as main objective to define the emission of the radiation by different angles of an encapsulated neutron source. The measurements were performed using a Long Accuracy Counter (PLC) Detector in the Low Dispersion Room of the LNMRI / IRD with different neutron sources. Each measurement was made using a support for the source, emulated through an arduino system to rotate it. The carrier is marked with a variation of 5 °, ranging from 0 ° to 360 °, for the work in question only half, 0 ° to 180 ° is used for a total of nineteen steps. In this paper three sources of {sup 241}AmBe (α, n) 5.92 GBq (16 Ci) were used, neutron sources having the following dimensions: 105 mm in height and 31 mm in diameter. The PLC was positioned at a distance of 2 meters from the neutron source and has a radius of 15 cm for the detection area. The anisotropy factor of the {sup 241}AmBe source was 17%. The results in this work will focus mainly on the area of radioprotection and studies that will improve the process of routine measurements in laboratories and instrument calibrations. (author)

  9. Neonatal and maternal outcomes of successful manual rotation to correct malposition of the fetal head; A retrospective and prospective observational study.

    Science.gov (United States)

    Tempest, Nicola; McGuinness, Naomi; Lane, Steven; Hapangama, Dharani K

    2017-01-01

    To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation. Prospective and retrospective observational study. Delivery suite in a tertiary referral teaching hospital in England. A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006-2013. Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section). Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia) and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml) and obstetric anal sphincter injury). Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346) of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349) shoulder dystocia, 2% (7/349) massive obstetric haemorrhage and 1.7% (6/349) obstetric anal sphincter injury, similar to other methods of rotational births. Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training) and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth.

  10. Neutron structural biology

    Energy Technology Data Exchange (ETDEWEB)

    Niimura, Nobuo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    Neutron diffraction provides an experimental method of directly locating hydrogen atoms in protein which play important roles in physiological functions. However, there are relatively few examples of neutron crystallography in biology since it takes a lot of time to collect a sufficient number of Bragg reflections due to the low flux of neutrons illuminating the sample. In order to overcome the flux problem, we have successfully developed the neutron IP, where the neutron converter, {sup 6}Li or Gd, was mixed with a photostimulated luminescence material on flexible plastic support. Neutron Laue diffraction 2A data from tetragonal lysozyme were collected for 10 days with neutron imaging plates, and 960 hydrogen atoms in the molecule and 157 bound water molecules were identified. These results explain the proposed hydrolysis mechanism of the sugar by the lysozyme molecule and that lysozyme is less active at pH7.0. (author)

  11. Characterization of proton and neutron irradiated low resistivity p-on-n magnetic Czochralski ministrip sensors and diodes

    Energy Technology Data Exchange (ETDEWEB)

    Pacifico, Nicola, E-mail: nicola.pacifico@cern.ch [CERN, Geneva (Switzerland); Dolenc Kittelmann, Irena; Fahrer, Manuel; Moll, Michael [CERN, Geneva (Switzerland); Militaru, Otilia [UCL, Louvain (Belgium)

    2011-12-01

    Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements were performed on low resistivity (280{Omega}cm) n-bulk, p-readout magnetic Czochralski ministrip sensors and diodes. The detectors were irradiated with neutrons and 24 GeV/c protons up to a total NIEL equivalent fluence of 8 Multiplication-Sign 10{sup 15}/cm{sup 2}. The study was addressed to assess the radiation tolerance of the detectors up to fluences expected in the next generations of High Energy Physics experiments. The charge collection efficiency after irradiation was found to be much higher than for standard FZ silicon p-in-n sensors. The underlying physics of this remarkable result was investigated by performing Edge-TCT measurements on one of the neutron irradiated ministrip sensors to extract detailed informations about the field and efficiency profiles of the detector.

  12. Transmutants and its behaviors in heavy irradiated AlN by reactor neutrons

    International Nuclear Information System (INIS)

    Atobe, Kozo; Tashiro, Tomonori; Honda, Makoto; Fukuoka, Noboru; Matsukawa, Tokuo; Okada, Moritami; Nakagawa, Masuo.

    1997-01-01

    Transmutant production effects on the sintered aluminum nitride have been studied by neutron heavy irradiation using X-ray photoelectron spectroscopy analysis. The specimens are irradiated with fast neutrons in the ranges of 1.0x10 17 - 1.2x10 20 n/cm 2 . For high fluences (>10 18 n/cm 2 ), XPS observations show Si2s (153.8 eV) and Si2p (103.3 eV) peaks in XPS spectrum. The depth profiles using Ar-ion sputtering and the chemical shift of the peak indicate that 28 Si induced by 27 Al (n,γ) 28 Al reaction and β-decay of 28 Al precipitates near surface as oxidized silicon. (author)

  13. Phenomenological analisis of the p-even- and p,odd-angular asimmetry of alpha particles in the 10B(n, α)7Li reaction with thermal polarized neutrons

    International Nuclear Information System (INIS)

    Rzhevskij, E.S.

    1983-01-01

    The formalism for multilevel phenomfor munological analysis of angular asymmetry of alpha-particles escape from compound-nuclei in reactions induced by thermal polarized neutrons is suggested. The formalism is based on R-matrix theory of nuclear reactions. The connection of problems of angular correlations description with those of light nuclei structure is shown. The problems related to the selection of compound-resonance parameters, determination of alpha-cluster states, estimation of the role of these or those compound-resonances in neutron and alpha-particle channels are discussed. An explanation is given to the observed in the experiment p-even left/right angular asymmetry of alpha-particles. The values of p-odd angular correlations, the measurements of which are continued, are estimated

  14. Biological effectiveness of neutron irradiation on animals and man

    Energy Technology Data Exchange (ETDEWEB)

    Straume, T.

    1982-11-01

    Neutron experiments on a highly radiosensitive in vivo system - oocytes in mice - provide new insight into the nature of the radiosensitive targets of these important cells. With the radiobiological literature as background, neutron data from animals and humans are integrated, and the controversial question of radiation protection standards for neutrons is addressed. Oocyte killing in juvenile mice by 0.43-MeV, /sup 252/Cf-fission, and 15 MeV neutrons, compared with that by /sup 60/Co gamma rays, yields unusually low neutron RBEs (relative biological effectiveness). At 0.1 rad of 0.43-MeV neutrons the RBE is only 1.8, contrasting greatly with values of 100 or more reported at low-doses for other endpoints. In mice just prior to birth, however, when oocytes are less radiosensitive, the neutron RBE is much higher, similar to values for most other mammalian endpoints. This dramatic change in neutron RBE with mouse age (occurring within 2 to 3 days) can be explained as the result of a shift from a less radiosensitive target (presumably nuclear DNA) to a much more radiosensitive one (probably the oocyte plasma membrane). Using various approaches, a value for the neutron Quality Factor (Q, a radiation protection standard) is estimated as 17 (+-100%), much lower than 100 which has been suggested. With the large uncertainty, 17 is not markedly different from the value of 10 presently in general use.

  15. Biological effectiveness of neutron irradiation on animals and man

    International Nuclear Information System (INIS)

    Straume, T.

    1982-11-01

    Neutron experiments on a highly radiosensitive in vivo system - oocytes in mice - provide new insight into the nature of the radiosensitive targets of these important cells. With the radiobiological literature as background, neutron data from animals and humans are integrated, and the controversial question of radiation protection standards for neutrons is addressed. Oocyte killing in juvenile mice by 0.43-MeV, 252 Cf-fission, and 15 MeV neutrons, compared with that by 60 Co gamma rays, yields unusually low neutron RBEs (relative biological effectiveness). At 0.1 rad of 0.43-MeV neutrons the RBE is only 1.8, contrasting greatly with values of 100 or more reported at low-doses for other endpoints. In mice just prior to birth, however, when oocytes are less radiosensitive, the neutron RBE is much higher, similar to values for most other mammalian endpoints. This dramatic change in neutron RBE with mouse age (occurring within 2 to 3 days) can be explained as the result of a shift from a less radiosensitive target (presumably nuclear DNA) to a much more radiosensitive one (probably the oocyte plasma membrane). Using various approaches, a value for the neutron Quality Factor (Q, a radiation protection standard) is estimated as 17 (+-100%), much lower than 100 which has been suggested. With the large uncertainty, 17 is not markedly different from the value of 10 presently in general use

  16. Nuclear Dependence of the Transverse-Single-Spin Asymmetry for Forward Neutron Production in Polarized p +A Collisions at √{sN N}=200 GeV

    Science.gov (United States)

    Aidala, C.; Akiba, Y.; Alfred, M.; Andrieux, V.; Aoki, K.; Apadula, N.; Asano, H.; Ayuso, C.; Azmoun, B.; Babintsev, V.; Bagoly, A.; Bandara, N. S.; Barish, K. N.; Bathe, S.; Bazilevsky, A.; Beaumier, M.; Belmont, R.; Berdnikov, A.; Berdnikov, Y.; Blau, D. S.; Boer, M.; Bok, J. S.; Brooks, M. L.; Bryslawskyj, J.; Bumazhnov, V.; Butler, C.; Campbell, S.; Canoa Roman, V.; Cervantes, R.; Chi, C. Y.; Chiu, M.; Choi, I. J.; Choi, J. B.; Citron, Z.; Connors, M.; Cronin, N.; Csanád, M.; Csörgő, T.; Danley, T. W.; Daugherity, M. S.; David, G.; Deblasio, K.; Dehmelt, K.; Denisov, A.; Deshpande, A.; Desmond, E. J.; Dion, A.; Dixit, D.; Do, J. H.; Drees, A.; Drees, K. A.; Dumancic, M.; Durham, J. M.; Durum, A.; Elder, T.; Enokizono, A.; En'yo, H.; Esumi, S.; Fadem, B.; Fan, W.; Feege, N.; Fields, D. E.; Finger, M.; Finger, M.; Fokin, S. L.; Frantz, J. E.; Franz, A.; Frawley, A. D.; Fukuda, Y.; Gal, C.; Gallus, P.; Garg, P.; Ge, H.; Giordano, F.; Goto, Y.; Grau, N.; Greene, S. V.; Grosse Perdekamp, M.; Gunji, T.; Guragain, H.; Hachiya, T.; Haggerty, J. S.; Hahn, K. I.; Hamagaki, H.; Hamilton, H. F.; Han, S. Y.; Hanks, J.; Hasegawa, S.; Haseler, T. O. S.; He, X.; Hemmick, T. K.; Hill, J. C.; Hill, K.; Hollis, R. S.; Homma, K.; Hong, B.; Hoshino, T.; Hotvedt, N.; Huang, J.; Huang, S.; Imai, K.; Imrek, J.; Inaba, M.; Iordanova, A.; Isenhower, D.; Ito, Y.; Ivanishchev, D.; Jacak, B. V.; Jezghani, M.; Ji, Z.; Jiang, X.; Johnson, B. M.; Jorjadze, V.; Jouan, D.; Jumper, D. S.; Kang, J. H.; Kapukchyan, D.; Karthas, S.; Kawall, D.; Kazantsev, A. V.; Khachatryan, V.; Khanzadeev, A.; Kim, C.; Kim, D. J.; Kim, E.-J.; Kim, M.; Kim, M. H.; Kincses, D.; Kistenev, E.; Klatsky, J.; Kline, P.; Koblesky, T.; Kotov, D.; Kudo, S.; Kurita, K.; Kwon, Y.; Lajoie, J. G.; Lallow, E. O.; Lebedev, A.; Lee, S.; Leitch, M. J.; Leung, Y. H.; Lewis, N. A.; Li, X.; Lim, S. H.; Liu, L. D.; Liu, M. X.; Loggins, V.-R.; Lökös, S.; Lovasz, K.; Lynch, D.; Majoros, T.; Makdisi, Y. I.; Makek, M.; Malaev, M.; Manko, V. I.; Mannel, E.; Masuda, H.; McCumber, M.; McGaughey, P. L.; McGlinchey, D.; McKinney, C.; Mendoza, M.; Metzger, W. J.; Mignerey, A. C.; Mihalik, D. E.; Milov, A.; Mishra, D. K.; Mitchell, J. T.; Mitsuka, G.; Miyasaka, S.; Mizuno, S.; Montuenga, P.; Moon, T.; Morrison, D. P.; Morrow, S. I. M.; Murakami, T.; Murata, J.; Nagai, K.; Nagashima, K.; Nagashima, T.; Nagle, J. L.; Nagy, M. I.; Nakagawa, I.; Nakagomi, H.; Nakano, K.; Nattrass, C.; Niida, T.; Nouicer, R.; Novák, T.; Novitzky, N.; Novotny, R.; Nyanin, A. S.; O'Brien, E.; Ogilvie, C. A.; Orjuela Koop, J. D.; Osborn, J. D.; Oskarsson, A.; Ottino, G. J.; Ozawa, K.; Pantuev, V.; Papavassiliou, V.; Park, J. S.; Park, S.; Pate, S. F.; Patel, M.; Peng, W.; Perepelitsa, D. V.; Perera, G. D. N.; Peressounko, D. Yu.; Perezlara, C. E.; Perry, J.; Petti, R.; Phipps, M.; Pinkenburg, C.; Pisani, R. P.; Pun, A.; Purschke, M. L.; Radzevich, P. V.; Read, K. F.; Reynolds, D.; Riabov, V.; Riabov, Y.; Richford, D.; Rinn, T.; Rolnick, S. D.; Rosati, M.; Rowan, Z.; Runchey, J.; Safonov, A. S.; Sakaguchi, T.; Sako, H.; Samsonov, V.; Sarsour, M.; Sato, K.; Sato, S.; Schaefer, B.; Schmoll, B. K.; Sedgwick, K.; Seidl, R.; Sen, A.; Seto, R.; Sexton, A.; Sharma, D.; Shein, I.; Shibata, T.-A.; Shigaki, K.; Shimomura, M.; Shioya, T.; Shukla, P.; Sickles, A.; Silva, C. L.; Silvermyr, D.; Singh, B. K.; Singh, C. P.; Singh, V.; Skoby, M. J.; Slunečka, M.; Smith, K. L.; Snowball, M.; Soltz, R. A.; Sondheim, W. E.; Sorensen, S. P.; Sourikova, I. V.; Stankus, P. W.; Stoll, S. P.; Sugitate, T.; Sukhanov, A.; Sumita, T.; Sun, J.; Syed, S.; Sziklai, J.; Takeda, A.; Tanida, K.; Tannenbaum, M. J.; Tarafdar, S.; Taranenko, A.; Tarnai, G.; Tieulent, R.; Timilsina, A.; Todoroki, T.; Tomášek, M.; Towell, C. L.; Towell, R. S.; Tserruya, I.; Ueda, Y.; Ujvari, B.; van Hecke, H. W.; Vazquez-Carson, S.; Velkovska, J.; Virius, M.; Vrba, V.; Vukman, N.; Wang, X. R.; Wang, Z.; Watanabe, Y.; Watanabe, Y. S.; Wong, C. P.; Woody, C. L.; Xu, C.; Xu, Q.; Xue, L.; Yalcin, S.; Yamaguchi, Y. L.; Yamamoto, H.; Yanovich, A.; Yin, P.; Yoo, J. H.; Yoon, I.; Yu, H.; Yushmanov, I. E.; Zajc, W. A.; Zelenski, A.; Zharko, S.; Zou, L.; Phenix Collaboration

    2018-01-01

    During 2015, the Relativistic Heavy Ion Collider (RHIC) provided collisions of transversely polarized protons with Au and Al nuclei for the first time, enabling the exploration of transverse-single-spin asymmetries with heavy nuclei. Large single-spin asymmetries in very forward neutron production have been previously observed in transversely polarized p +p collisions at RHIC, and the existing theoretical framework that was successful in describing the single-spin asymmetry in p +p collisions predicts only a moderate atomic-mass-number (A ) dependence. In contrast, the asymmetries observed at RHIC in p +A collisions showed a surprisingly strong A dependence in inclusive forward neutron production. The observed asymmetry in p +Al collisions is much smaller, while the asymmetry in p +Au collisions is a factor of 3 larger in absolute value and of opposite sign. The interplay of different neutron production mechanisms is discussed as a possible explanation of the observed A dependence.

  17. Neutron diffraction studies on Ca1− xBaxZr4P6O24 solid solutions

    Indian Academy of Sciences (India)

    P6O24 compositions from combined Rietveld refinements of powder X-ray and neutron diffraction data. All the studied compositions crystallize in rhombohedral lattice (space group R-3 No. 148). A continuous solid solution is concluded from ...

  18. $^{11}$Be($\\beta$p), a quasi-free neutron decay?

    CERN Document Server

    Riisager, K.; Borge, M.J.G.; Briz, J.A.; Carmona-Gallardo, M.; Fraile, L.M.; Fynbo, H.O.U.; Giles, T.; Gottberg, A.; Heinz, A.; Johansen, J.G.; Jonson, B.; Kurcewicz, J.; Lund, M.V.; Nilsson, T.; Nyman, G.; Rapisarda, E.; Steier, P.; Tengblad, O.; Thies, R.; Winkler, S.R.

    2014-01-01

    We have observed $\\beta$-delayed proton emission from the neutron-rich nucleus $^{11}$Be by analysing a sample collected at the ISOLDE facility at CERN with accelerator mass spectrometry (AMS). With a branching ratio of (8.4 $\\pm$ 0.6)$\\times$ 10$^{-6}$ the strength of this decay mode, as measured by the B$_\\mathrm{GT}$-value, is unexpectedly high. The result is discussed within a simple single-particle model and could be interpreted as a quasi-free decay of the $^{11}$Be halo neutron into a single-proton state.

  19. Determination of allowable ramp power levels to maintain the mechanical integrity for 14x14, 16x16 and 17x17 KOFAs

    International Nuclear Information System (INIS)

    Lee, Chan Bok; Kim, Ki Hang; Kim, Kyu Tae

    1991-11-01

    Transient behavior of the fuel rods with various rod power histories for 17x17 KOFA fuels has been calculated and evaluated, and sensitivity analyses of the key parameters such as rod power history before ramp, fast neutron flux and cycle length have also been performed. Results show that cladding strain is more limiting in determining the allowable ramp power level than fuel centerline temperature, and neutron flux has greatest influence on fuel transient behavior among rod power history before ramp, fast neutron flux and cycle length. Based upon the above results, allowable ramp power levels versus burnup for 14x14, 16x16 and 17x17 KOFA fuels were determined for the rods with different initial power levels of F xy = 0.6, 0.8, 1.0 and 1.2, which shows that the rod with lower initial power level gives lower allowable ramp power level. It can be said, therefore, that if the ramp power level of the rod at certain initial power level and burnup is less than the corresponding allowable ramp power level, the transient behavior of the rod satisfy the fuel rod design criteria. (Author)

  20. Polarized epithermal neutron studies of magnetic domains

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Chernikov, A.N.; Lason, L.; Mareev, Y.D.; Novitsky, V.V.; Pikelner, L.B.; Skoy, V.R.; Tsulaya, M.I.; Gould, C.R.; Haase, D.G.; the Triangle Universities Nuclear Laboratory, Durham, North Carolina; Roberson, N.R.; the Triangle Universities Nuclear Laboratory, Durham, North Carolina

    1997-01-01

    The average size and shape of magnetic domains in a material can be determined from the precession of polarized neutrons traversing the material. Epithermal neutrons (0.5eV n <100eV), which precess more slowly than thermals, effectively probe the internal structure of samples that are thick or have large domains or large internal fields. Such epithermal neutron measurements require a neutron polarizer and analyzer based on cryogenically polarized spin filters. We discuss the measurement at JINR, Dubna, of magnetic domains in a 2.0 cm. diam. crystal of holmium using 1.7 to 59 eV neutrons polarized by a dynamically polarized proton target and analyzed with a statically polarized dysprosium target. copyright 1997 American Institute of Physics

  1. By Targeting Stat3 microRNA-17-5p Promotes Cardiomyocyte Apoptosis in Response to Ischemia Followed by Reperfusion

    Directory of Open Access Journals (Sweden)

    Weijie Du

    2014-08-01

    Full Text Available Background: Several studies have confirmed the role of microRNAs in regulating ischemia/reperfusion-induced cardiac injury (I/R-I. MiR-17-5p has been regarded as an oncomiR in the development of cancer. However, its potential role in cardiomyocytes has not been exploited. The aim of this study is to investigate the role of miR-17-5p in I/R-I and the underlying mechanism through targeting Stat3, a key surviving factor in cardiomyocytes. Methods: MTT (3-[4, 5-dimethylthiazol-2-yl]-2, 5 diphenyl tetrazolium bromide assay was used to detect the cell viability. ELISA and TUNEL were performed to measure apoptosis of neonatal rat ventricular cardiomyocytes (NRVCs. Infarct area was estimated by TTC (triphenyltetrazolium chloride and Evans blue staining. Western blot analysis was employed to detect the Stat3 and p-Stat3 levels and real-time RT-PCR was used to quantify miR-17-5p level. Results: The miR-17-5p level was significantly up-regulated in I/R-I mice and in NRVCs under oxidative stress. Overexpression of miR-17-5p aggravated cardiomyocyte injury with reduced cell viability and enhanced apoptotic cell death induced by H2O2, whereas inhibition of miR-17-5p by its antisense AMO-17-5p abrogated the deleterious changes. Moreover, the locked nucleic acid-modified antisense (LNA-anti-miR-17-5p markedly decreased the infarct area and apoptosis induced by I/R-I in mice. Furthermore, overexpression of miR-17-5p diminished the p-Stat3 level in response to H2O2. The results from Western blot analysis and luciferase reporter gene assay confirmed Stat3 as a target gene for miR-17-5p. Conclusion: Upregulation of miR-17-5p promotes apoptosis induced by oxidative stress via targeting Stat3, accounting partially for I/R-I.

  2. The cross-section data from neutron activation experiments on niobium in the NPI p-7Li quasi-monoenergetic neutron field

    Directory of Open Access Journals (Sweden)

    Simakov S.P.

    2010-10-01

    Full Text Available The reaction of protons on 7Li target produces the high-energy quasi- monoenergetic neutron spectrum with the tail to lower energies. Proton energies of 19.8, 25.1, 27.6, 30.1, 32.6, 35.0 and 37.4 MeV were used to obtain quasi-monoenergetic neutrons with energies of 18, 21.6, 24.8, 27.6, 30.3, 32.9 and 35.6 MeV, respectively. Nb cross-section data for neutron energies higher than 22.5 MeV do not exist in the literature. Nb is the important material for fusion applications (IFMIF as well. The variable-energy proton beam of NPI cyclotron is utilized for the production of neutron field using thin lithium target. The carbon backing serves as the beam stopper. The system permits to produce neutron flux density about 109  n/cm2/s in peak at 30 MeV neutron energy. The niobium foils of 15 mm in diameter and approx. 0.75 g weight were activated. The nuclear spectroscopy methods with HPGe detector technique were used to obtain the activities of produced isotopes. The large set of neutron energies used in the experiment allows us to make the complex study of the cross-section values. The reactions (n,2n, (n,3n, (n,4n, (n,He3, (n,α and (n,2nα are studied. The cross-sections data of the (n,4n and (n,2nα are obtained for the first time. The cross-sections of (n,2n and (n,α reactions for higher neutron energies are strongly influenced by low energy tail of neutron spectra. This effect is discussed. The results are compared with the EAF-2007 library.

  3. Utilization and facility of neutron activation analysis in HANARO research reactor

    International Nuclear Information System (INIS)

    Chung, Y.S.; Chung, Y.J.; Moon, J.H.

    1998-01-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10 13 -1.6x10 14 n/cm 2 ·s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  4. Measurements of fusion neutron multiplication in spherical beryllium shells

    International Nuclear Information System (INIS)

    Giese, H.; Kappler, F.; Tayama, R.; Moellendorff, U. von; Alevra, A.; Klein, H.

    1996-01-01

    New results of spherical-shell transmission measurements with 14-MeV neutrons on pure beryllium shells up to 17 cm thick are reported. The spectral flux above 3 MeV was measured using a liquid scintillation detector. At 17 cm thickness, also the total neutron multiplication was measured using a Bonner sphere system. The results agree well with calculations using beryllium nuclear data from the EFF-1 or the ENDF/B-Vi library. (author). 23 refs, 4 figs, 1 tab

  5. Measurements of the Fe-54 (n,p) Mn-54 Reaction Cross Section in the Neutron Energy Range 2.3-3.8 MeV

    International Nuclear Information System (INIS)

    Lauber, A.; Malmskog, S.

    1964-10-01

    We have measured the 54 Fe (n, p) 54 Mn reaction cross section using a surface barrier detector to record the number of protons released in the reaction. The neutron flux was determined by means of a hydrogenous radiator, detecting the scattered protons with the solid state detector, and calculating the number of impinging neutrons from the well known n-p scattering cross section. The 54 Fe (n, p) 54 Mn reaction cross section is found to increase from 25 mb at 2.3 MeV to 208 mb at 3.5 MeV

  6. Development of Process Automation in the Neutron Activation Analysis Facility in Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Yussup, N.; Azman, A.; Ibrahim, M.M.; Rahman, N.A.A.; Che Sohashaari, S.; Atan, M.N.; Hamzah, M.A.; Mokhtar, M.; Khalid, M.A.; Salim, N.A.A.; Hamzah, M.S.

    2018-01-01

    Neutron Activation Analysis (NAA) has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established from sample registration to analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, system automation is developed in order to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This report explains NAA process in Nuclear Malaysia and describes the automation development in detail which includes sample registration software, automatic sample changer system which consists of hardware and software; and sample analysis software. (author)

  7. 5th symposium on neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Spurny, F

    1985-03-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of /sup 252/Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.).

  8. 5th symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.

    1985-01-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of 252 Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.)

  9. Electrical and optical properties of neutron-irradiated GaP crystals

    International Nuclear Information System (INIS)

    Kawakubo, T.; Okada, M.

    1990-01-01

    Infrared absorption, electron paramagnetic resonance (EPR) spectra, and the electrical resistivity of semi-insulating liquid encapsulated Czochralski GaP crystals irradiated by fast neutrons with a dose of 7.6x10 18 n cm -2 have been studied. The electrical resistivity decreases with irradiation from 10 6 Ω cm to 1.5 kΩ cm. The temperature dependence of resistivity at low temperature is fitted to exp(b/T 1/4 ). The strong continuous optical absorption extends to 0.32 eV and its tail spreads until 0.12 eV. The EPR spectrum exhibits a broad singlet at 77 K and a doublet with five line structures at room temperature, which is attributed to antisite defects P Ga . The strong infrared absorption begins to be annealed at 150 degree C, and the EPR broad singlet decreases with anneals in the same temperature range. The strong infrared absorption is assumed to arise from interstitial phosphorus clusters. A discussion is given concerning the species responsible for the EPR singlet

  10. Financial and environmental costs of manual versus automated control of end-tidal gas concentrations.

    Science.gov (United States)

    Tay, S; Weinberg, L; Peyton, P; Story, D; Briedis, J

    2013-01-01

    Emerging technologies that reduce the economic and environmental costs of anaesthesia have had limited assessment. We hypothesised that automated control of end-tidal gases, a new feature in anaesthesia machines, will consistently reduce volatile agent consumption cost and greenhouse gas emissions. As part of the planned replacement of anaesthesia machines in a tertiary hospital, we performed a prospective before and after study comparing the cost and greenhouse gas emissions of isoflurane, sevoflurane and desflurane when using manual versus automated control of end-tidal gases. We analysed 3675 general anaesthesia cases with inhalational agents: 1865 using manual control and 1810 using automated control. Volatile agent cost was $18.87/hour using manual control and $13.82/hour using automated control: mean decrease $5.05/hour (95% confidence interval: $0.88-9.22/hour, P=0.0243). The 100-year global warming potential decreased from 23.2 kg/hour of carbon dioxide equivalents to 13.0 kg/hour: mean decrease 10.2 kg/hour (95% confidence interval: 2.7-17.7 kg/hour, P=0.0179). Automated control reduced costs by 27%. Greenhouse gas emissions decreased by 44%, a greater than expected decrease facilitated by a proportional reduction in desflurane use. Automated control of end-tidal gases increases participation in low flow anaesthesia with economic and environmental benefits.

  11. miR-17-5p targets the p300/CBP-associated factor and modulates androgen receptor transcriptional activity in cultured prostate cancer cells

    International Nuclear Information System (INIS)

    Gong, Ai-Yu; Eischeid, Alex N; Xiao, Jing; Zhao, Jian; Chen, Dongqing; Wang, Zhao-Yi; Young, Charles YF; Chen, Xian-Ming

    2012-01-01

    Androgen receptor (AR) signalling is critical to the initiation and progression of prostate cancer (PCa). Transcriptional activity of AR involves chromatin recruitment of co-activators, including the p300/CBP-associated factor (PCAF). Distinct miRNA expression profiles have been identified in PCa cells during the development and progression of the disease. Whether miRNAs regulate PCAF expression in PCa cells to regulate AR transcriptional activity is still unclear. Expression of PCAF was investigated in several PCa cell lines by qRT-PCR, Western blot, and immunocytochemistry. The effects of PCAF expression on AR-regulated transcriptional activity and cell growth in PCa cells were determined by chromatin immunoprecipitation, reporter gene construct analysis, and MTS assay. Targeting of PCAF by miR-17-5p was evaluated using the luciferase reporter assay. PCAF was upregulated in several PCa cell lines. Upregulation of PCAF promoted AR transcriptional activation and cell growth in cultured PCa cells. Expression of PCAF in PCa cells was associated with the downregulation of miR-17-5p. Targeting of the 3’-untranslated region of PCAF mRNA by miR-17-5p caused translational suppression and RNA degradation, and, consequently, modulation of AR transcriptional activity in PCa cells. PCAF is upregulated in cultured PCa cells, and upregulation of PCAF is associated with the downregulation of miR-17-5p. Targeting of PCAF by miR-17-5p modulates AR transcriptional activity and cell growth in cultured PCa cells

  12. Time-of-flight neutron diffraction investigation of temperature factors in the Zn blende semiconductor InP

    International Nuclear Information System (INIS)

    Ferrari, C.; Bocchi, C.; Fornari, R.; Moze, O.; Wilson, C.C.

    1992-01-01

    A structural investigation of the Zn blende structure semiconductor InP has been carried out using the single crystal diffractometer SXD at the pulsed neutron facility ISIS. The ability to measure structure factors accurately at large Q values even with highly absorbing materials such as InP is demonstrated. Measurements were performed on a single crystal of InP at 293, 100 and 50 K with the crystallographic axis mounted perpendicular to the scattering plane. This enabled collection of (hhl) reflections up to a maximum with Miller indices (10, 10, 8). (orig.)

  13. Comparative study of neutron and gamma-ray pulse shape discrimination of anthracene, stilbene, and p-terphenyl

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Watanabe, Kenichi; Fujimoto, Yutaka

    2015-01-01

    Solid state organic scintillators, such as anthracene, stilbene, and p-terphenyl were investigated on their basic scintillation properties and neutron–gamma discrimination capabilities. Scintillation wavelengths under X-ray irradiation of anthracene, stilbene, and p-terphenyl were 445–525, 400–500, and 350–450 nm, respectively. Scintillation light yields of anthracene, stilbene, and p-terphenyl under 137 Cs gamma-ray irradiation were 20100, 16000, and 19400 ph/MeV, respectively. Neutron and gamma-ray events discrimination capabilities were examined and anthracene exhibited the best figure of merit among three organic scintillators

  14. Comparative study of neutron and gamma-ray pulse shape discrimination of anthracene, stilbene, and p-terphenyl

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Takayuki, E-mail: yanagida@lsse.kyutech.ac.jp [Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu, Kitakyushu, Fukuoka 808-0196 (Japan); Watanabe, Kenichi [Nagoya University, Furocho, Chikusa, Nagoya 464-8603 (Japan); Fujimoto, Yutaka [Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu, Kitakyushu, Fukuoka 808-0196 (Japan)

    2015-06-01

    Solid state organic scintillators, such as anthracene, stilbene, and p-terphenyl were investigated on their basic scintillation properties and neutron–gamma discrimination capabilities. Scintillation wavelengths under X-ray irradiation of anthracene, stilbene, and p-terphenyl were 445–525, 400–500, and 350–450 nm, respectively. Scintillation light yields of anthracene, stilbene, and p-terphenyl under {sup 137}Cs gamma-ray irradiation were 20100, 16000, and 19400 ph/MeV, respectively. Neutron and gamma-ray events discrimination capabilities were examined and anthracene exhibited the best figure of merit among three organic scintillators.

  15. Neutron and gamma probes: Their use in agronomy. Second edition; Sondas de neutrones y gamma: Sus aplicaciones en agronomia. Segunda edicion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-02-01

    , water and nutrient management within cropping systems. In this context, neutron moisture probes in combination with isotope techniques are utilized to obtain precise and quantitative data on water and nutrient dynamics in the soil-plant system. The Centre for Nuclear Techniques in Agriculture (CENA) of the University of Sao Paulo, Piracicaba, Brazil is an institute established with IAEA support, with skilled and experienced staff and facilities to utilize nuclear techniques in agronomic and related environmental research. Many training events and formal undergraduate and post-graduate courses involving the use of neutron moisture meters have been offered by CENA. The concept of a training manual originated during a regional training workshop on the use of the neutron probe in water and nutrient balance studies, organized in 1997 in the frame of an IAEA Regional Technical Co-operation Project for Latin America entitled Plant Nutrition, Water and Soil Management (RLA/5/036-ARCAL XXII), for which the integrated approach was adopted. The original version (in Spanish) was a comprehensive manual covering theoretical and practical aspects required for the proper utilization of the equipment. It is hoped that this manual will be useful for future training events and serve as a key reference to soil/water scientists in the field of sustainable management of scarce water resources in both rain-fed and irrigated agricultural production systems.

  16. Duplication of 17(p11.2p11.2) in a male child with autism and severe language delay.

    Science.gov (United States)

    Nakamine, Alisa; Ouchanov, Leonid; Jiménez, Patricia; Manghi, Elina R; Esquivel, Marcela; Monge, Silvia; Fallas, Marietha; Burton, Barbara K; Szomju, Barbara; Elsea, Sarah H; Marshall, Christian R; Scherer, Stephen W; McInnes, L Alison

    2008-03-01

    Duplications of 17(p11.2p11.2) have been associated with various behavioral manifestations including attention deficits, obsessive-compulsive symptoms, autistic traits, and language delay. We are conducting a genetic study of autism and are screening all cases for submicroscopic chromosomal abnormalities, in addition to standard karyotyping, and fragile X testing. Using array-based comparative genomic hybridization analysis of data from the Affymetrix GeneChip(R) Human Mapping Array set, we detected a duplication of approximately 3.3 Mb on chromosome 17p11.2 in a male child with autism and severe expressive language delay. The duplication was confirmed by measuring the copy number of genomic DNA using quantitative polymerase chain reaction. Gene expression analyses revealed increased expression of three candidate genes for the Smith-Magenis neurobehavioral phenotype, RAI1, DRG2, and RASD1, in transformed lymphocytes from Case 81A, suggesting gene dosage effects. Our results add to a growing body of evidence suggesting that duplications of 17(p11.2p11.2) result in language delay as well as autism and related phenotypes. As Smith-Magenis syndrome is also associated with language delay, a gene involved in acquisition of language may lie within this interval. Whether a parent of origin effect, gender of the case, the presence of allelic variation, or changes in expression of genes outside the breakpoints influence the resultant phenotype remains to be determined. (c) 2007 Wiley-Liss, Inc.

  17. Elements and process for recording direct image neutron radiographs

    International Nuclear Information System (INIS)

    Poignant, R.V. Jr.; Przybylowicz, E.P.

    1975-01-01

    An element is provided for recording a direct image neutron radiograph, thus eliminating the need for a transfer step (i.e., the use of a transfer screen). The element is capable of holding an electrostatic charge and comprises a first layer for absorbing neutrons and generating a current by dissipation of said electrostatic charge in proportion to the number of neutrons absorbed, and a second layer for conducting the current generated by the absorbed neutrons, said neutron absorbing layer comprising an insulative layer comprising neutron absorbing agents in a concentration of at least 10 17 atoms per cm 3 . An element for enhancing the effect of the neutron beam by utilizing the secondary emanations of neutron absorbing materials is also disclosed along with a process for using the device. (U.S.)

  18. An inelastic neutron scattering determination of the temperature dependence of the 3d-4f exchange interaction in Sm2Fe17

    International Nuclear Information System (INIS)

    Solodovnikov, Anton; Loewenhaupt, Michael; Moze, Oscar; Kuz'min, Michael D.; Bewley, Robert

    2002-01-01

    High energy transfer inelastic neutron scattering has been used to investigate the temperature dependence in the range from 20 to 450 K of the intermultiplet transition E inter in the intermetallic compound Sm 2 Fe 17 . The peak due to this transition, observed in the inelastic neutron spectrum, shifts to lower energies with increasing temperature. From the temperature dependence of E inter , the temperature dependence of the exchange field B ex acting on the Sm ion has been established experimentally, as the energy of the intermultiplet transition provides a direct value for the exchange field. At the highest measured temperature T=450 K, which is above the Curie point of 389 K for this compound, the transition energy is situated just above the bare spin-orbit splitting for Sm 3+ . The method utilized in the present investigation offers a rather easy and direct way to determine B ex in a large range of Sm intermetallics, which form an interesting class of hard magnetic materials

  19. The duplication 17p13.3 phenotype

    DEFF Research Database (Denmark)

    Curry, Cynthia J; Rosenfeld, Jill A; Grant, Erica

    2013-01-01

    . Older patients were often overweight. Three variant phenotypes included cleft lip/palate (CLP), split hand/foot with long bone deficiency (SHFLD), and a connective tissue phenotype resembling Marfan syndrome. The duplications in patients with clefts appear to disrupt ABR, while the SHFLD phenotype......Chromosome 17p13.3 is a gene rich region that when deleted is associated with the well-known Miller-Dieker syndrome. A recently described duplication syndrome involving this region has been associated with intellectual impairment, autism and occasional brain MRI abnormalities. We report 34...... was associated with duplication of BHLHA9 as noted in two recent reports. The connective tissue phenotype did not have a convincing critical region. Our experience with this large cohort expands knowledge of this diverse duplication syndrome....

  20. The polarization of fast neutrons

    International Nuclear Information System (INIS)

    Talov, V.V.

    2001-01-01

    It is insufficient to know coordinates and momentum to describe a state of a neutron. It is necessary to define a spin orientation. As far as it is known from quantum mechanics, a half spin has a projection in the positive direction or in the negative direction. The probability of both projections in an unpolarized beam is equal. If a direction exists, in which the projection is more probably then beam is called polarized in this direction. It is essential to know polarization of neutrons for characteristics of a neutron source, which is emitting it. The question of polarization of fast neutrons came up in 50's. The present work is the review of polarization of fast neutrons and methods of polarization analysis. This also includes information about polarization of fast neutrons from first papers, which described polarization in the D(d,n) 3 He, 7 Li (p,n) 7 Be, T(p,n) 3 He reactions. (authors)

  1. GADRAS-DRF 18.5 User's Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Horne, Steven M.; Thoreson, Gregory G; Theisen, Lisa A.; Mitchell, Dean J.; Harding, Lee; Amai, Wendy A.

    2014-12-01

    The Gamma Detector Response and Analysis Software - Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

  2. GADRAS-DRF 18.6 User's Manual

    Energy Technology Data Exchange (ETDEWEB)

    Horne, Steve M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Nuclear Threat Science; Thoreson, Greg G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Nuclear Threat Science; Theisen, Lisa A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Nuclear Threat Science; Mitchell, Dean J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Nuclear Threat Science; Harding, Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Nuclear Threat Science; Amai, Wendy A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Robotic Security Systems

    2016-05-01

    The Gamma Detector Response and Analysis Software–Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

  3. SERA: Simulation Environment for Radiotherapy Applications - Users Manual Version 1CO

    International Nuclear Information System (INIS)

    Venhuizen, James Robert; Wessol, Daniel Edward; Wemple, Charles Alan; Wheeler, Floyd J; Harkin, G. J.; Frandsen, M. W.; Albright, C. L.; Cohen, M.T.; Rossmeier, M.; Cogliati, J.J.

    2002-01-01

    This document is the user manual for the Simulation Environment for Radiotherapy Applications (SERA) software program developed for boron-neutron capture therapy (BNCT) patient treatment planning by researchers at the Idaho National Engineering and Environmental Laboratory (INEEL) and students and faculty at Montana State University (MSU) Computer Science Department. This manual corresponds to the final release of the program, Version 1C0, developed to run under the RedHat Linux Operating System (version 7.2 or newer) or the Solaris Operating System (version 2.6 or newer). SERA is a suite of command line or interactively launched software modules, including graphical, geometric reconstruction, and execution interface modules for developing BNCT treatment plans. The program allows the user to develop geometric models of the patient as derived from Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) images, perform dose computation for these geometric models, and display the computed doses on overlays of the original images as three dimensional representations. This manual provides a guide to the practical use of SERA, but is not an exhaustive treatment of each feature of the code

  4. SERA: Simulation Environment for Radiotherapy Applications - Users Manual Version 1CO

    Energy Technology Data Exchange (ETDEWEB)

    Venhuizen, James Robert; Wessol, Daniel Edward; Wemple, Charles Alan; Wheeler, Floyd J; Harkin, G. J.; Frandsen, M. W.; Albright, C. L.; Cohen, M.T.; Rossmeier, M.; Cogliati, J.J.

    2002-06-01

    This document is the user manual for the Simulation Environment for Radiotherapy Applications (SERA) software program developed for boron-neutron capture therapy (BNCT) patient treatment planning by researchers at the Idaho National Engineering and Environmental Laboratory (INEEL) and students and faculty at Montana State University (MSU) Computer Science Department. This manual corresponds to the final release of the program, Version 1C0, developed to run under the RedHat Linux Operating System (version 7.2 or newer) or the Solaris™ Operating System (version 2.6 or newer). SERA is a suite of command line or interactively launched software modules, including graphical, geometric reconstruction, and execution interface modules for developing BNCT treatment plans. The program allows the user to develop geometric models of the patient as derived from Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) images, perform dose computation for these geometric models, and display the computed doses on overlays of the original images as three dimensional representations. This manual provides a guide to the practical use of SERA, but is not an exhaustive treatment of each feature of the code.

  5. Neutron-Neutron effective range from a comparison of n-n and n-p quasi-free scattering at 24 MeV

    International Nuclear Information System (INIS)

    Witsch, W. von; Gomez Moreno, B.; Rosenstock, W.; Franke, R.; Steinheuer, B.

    1980-01-01

    Neutron-neutron and neutron-proton quasi-free scattering have been measured at Esub(n) = 24 MeV the d + n reaction to deduce the n-n effective range from a comparison of relative cross sections, reducing considerably experimental as well as theoretical uncertainties. A Monte Carlo analysis with exact three-body calculations yields rsub(nn) = 2.65 +- 0.18 fm. (orig.)

  6. Study on the energy response to neutrons for a new scintillating-fiber-array neutron detector

    CERN Document Server

    Zhang Qi; Wang Qun; Xie Zhong Shen

    2003-01-01

    The energy response of a new scintillating-fiber-array neutron detector to neutrons in the energy range 0.01 MeV<=E sub n<=14 MeV was modeled by combining a simplified Monte Carlo model and the MCNP 4b code. In order to test the model and get the absolute sensitivity of the detector to neutrons, one experiment was carried out for 2.5 and 14 MeV neutrons from T(p,n) sup 3 He and T(d,n) sup 4 He reactions at the Neutron Generator Laboratory at the Institute of Modern Physics, the Chinese Academy of Science. The absolute neutron fluence was obtained with a relative standard uncertainty 4.5% or 2.0% by monitoring the associated protons or sup 4 He particles, respectively. Another experiment was carried out for 0.5, 1.0, 1.5, 2.0, 2.5 MeV neutrons from T(p,n) sup 3 He reaction, and for 3.28, 3.50, 4.83, 5.74 MeV neutrons from D(d,n) sup 3 He reaction on the Model 5SDH-2 accelerator at China Institute of Atomic Energy. The absolute neutron fluence was obtained with a relative standard uncertainty 5.0% by usin...

  7. One-neutron and two-neutron transfer in the scattering

    International Nuclear Information System (INIS)

    Reisdorf, W.N.; Lau, P.H.; Vandenbosch, R.

    1975-01-01

    Angular distributions have been measured for one- and two-neutron transfer reactions induced by 18 O beams on 16 O targets at laboratory bombarding energies of 42 and 52 MeV. The reactions populating the ground and first excited states of 17 O and 18 O are analyzed in terms of single step finite range plus recoil DWBA theory taking into account antisymmetrization effects. Special attention is paid to an internally consistent description of the observed absolute magnitudes of all the reactions and to the theoretically expected interferences between various backward-forward scattering mechanisms. The importance of neutron transfer in accounting for different absorbing properties of the 16 O- 18 O systems as compared to the 16 O- 16 O system is shown. (13 figures, 2 tables)

  8. ISINN-5. 5. International seminar on interaction of neutrons with nuclei. Neutron spectroscopy, nuclear structure, related topics

    International Nuclear Information System (INIS)

    1997-01-01

    The materials submitted at the fifth in a series of annual international seminar on interaction of neutrons with nuclei Neutron Spectroscopy, Nuclear Structure, Related Topics (ISINN-5) are given. The Seminar is organized by the Frank Laboratory of Neutron Physics of the Joint Institute for Nuclear Research and took place in Dubna on May 14-17, 1997. About 130 specialists from Belgium, China, Germany, France, Japan, Korea, Latvia, Netherlands, Ukraine, 7 Russian research institutes and a number of JINR laboratories took part in the Seminar. The scope of the problems discussed is traditionally wide. It includes the problems of violation of fundamental symmetries in the interaction of neutrons with nuclei, the properties of the neutron as the fundamental particle, nonstatistical aspects of the radiation capture of neutrons by nuclei, topical problems of the theory of nucleus, and the fission mechanism of heavy nuclei. The latest results obtained with ultracold neutrons (UCN), in particular, different approaches to understanding of the cause of UCN anomalous leakage through the walls of the trap are considered as well. The wide spectrum of methodological aspects of neutron-aided experiments is also discussed in details

  9. Invariant mass spectroscopy of {sup 19,17}C and {sup 14}B using proton inelastic and charge-exchange reactions

    Energy Technology Data Exchange (ETDEWEB)

    Satou, Y., E-mail: satou@phya.snu.ac.k [Department of Physics and Astronomy, Seoul National University, Seoul (Korea, Republic of); Nakamura, T. [Department of Physics, Tokyo Institute of Technology, Tokyo (Japan); Fukuda, N. [Institute of Physical and Chemical Research (RIKEN), Saitama (Japan); Sugimoto, T.; Kondo, Y.; Matsui, N.; Hashimoto, Y.; Nakabayashi, T.; Okumura, Y.; Shinohara, M. [Department of Physics, Tokyo Institute of Technology, Tokyo (Japan); Motobayashi, T.; Yanagisawa, Y.; Aoi, N.; Takeuchi, S.; Gomi, T.; Togano, Y. [Institute of Physical and Chemical Research (RIKEN), Saitama (Japan); Kawai, S. [Department of Physics, Rikkyo University, Tokyo (Japan); Sakurai, H. [Institute of Physical and Chemical Research (RIKEN), Saitama (Japan); Ong, H.J.; Onishi, T.K. [Department of Physics, University of Tokyo, Tokyo (Japan)

    2010-03-01

    The neutron-rich carbon isotopes {sup 19,17}C and the boron isotope {sup 14}B have been investigated, respectively, by the proton inelastic and charge-exchange reactions on a liquid hydrogen target at around 70 MeV/nucleon. The invariant mass method in inverse kinematics was employed to map the energy spectrum above the neutron decay threshold of the residual nuclei. New states on carbon isotopes are reported. An experimental capability of extracting beta-decay strengths via forward angle (p,n) cross sections on unstable nuclei is shown.

  10. Development of a neutron personal dose equivalent detector

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.; Momose, T.; Nunomiya, T.; Aoyama, K.

    2007-01-01

    A new neutron-measuring instrument that is intended to measure a neutron personal dose equivalent, H p (10) was developed. This instrument is composed of two parts: (1) a conventional moderator-based neutron dose equivalent meter and (2) a neutron shield made of borated polyethylene, which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics that would generally match both the energy and angular dependencies of H p (10). This new instrument will be a great help in assessing the reference values of neutron H p (10) during field testing of personal neutron dosemeters in workplaces and also in interpreting their readings. (authors)

  11. Superintensive pulse slow neutron source SIN based on kaon factory

    International Nuclear Information System (INIS)

    Kolmichkov, N.V.; Laptev, V.D.; Matveev, V.A.

    1991-01-01

    Possibility of intensive pulse slow neutron source creation based on 45-GeV proton synchrotron of K-meson factory, planned to construction in INR AS USSR is considered. Calculated peak thermal neutrons flux density value, averaged on 'radiating' light-water moderator surface of 100 cm 2 is 6.6 x 10 17 neutrons/(cm 2 sec) for pulse duration of 35 microseconds. (author)

  12. Prompt fission neutron spectra and average prompt neutron multiplicities

    International Nuclear Information System (INIS)

    Madland, D.G.; Nix, J.R.

    1983-01-01

    We present a new method for calculating the prompt fission neutron spectrum N(E) and average prompt neutron multiplicity anti nu/sub p/ as functions of the fissioning nucleus and its excitation energy. The method is based on standard nuclear evaporation theory and takes into account (1) the motion of the fission fragments, (2) the distribution of fission-fragment residual nuclear temperature, (3) the energy dependence of the cross section sigma/sub c/ for the inverse process of compound-nucleus formation, and (4) the possibility of multiple-chance fission. We use a triangular distribution in residual nuclear temperature based on the Fermi-gas model. This leads to closed expressions for N(E) and anti nu/sub p/ when sigma/sub c/ is assumed constant and readily computed quadratures when the energy dependence of sigma/sub c/ is determined from an optical model. Neutron spectra and average multiplicities calculated with an energy-dependent cross section agree well with experimental data for the neutron-induced fission of 235 U and the spontaneous fission of 252 Cf. For the latter case, there are some significant inconsistencies between the experimental spectra that need to be resolved. 29 references

  13. Cosmogenic neutron production at Daya Bay

    Science.gov (United States)

    An, F. P.; Balantekin, A. B.; Band, H. R.; Bishai, M.; Blyth, S.; Cao, D.; Cao, G. F.; Cao, J.; Chan, Y. L.; Chang, J. F.; Chang, Y.; Chen, H. S.; Chen, S. M.; Chen, Y.; Chen, Y. X.; Cheng, J.; Cheng, Z. K.; Cherwinka, J. J.; Chu, M. C.; Chukanov, A.; Cummings, J. P.; Ding, Y. Y.; Diwan, M. V.; Dolgareva, M.; Dove, J.; Dwyer, D. A.; Edwards, W. R.; Gill, R.; Gonchar, M.; Gong, G. H.; Gong, H.; Grassi, M.; Gu, W. Q.; Guo, L.; Guo, X. H.; Guo, Y. H.; Guo, Z.; Hackenburg, R. W.; Hans, S.; He, M.; Heeger, K. M.; Heng, Y. K.; Higuera, A.; Hsiung, Y. B.; Hu, B. Z.; Hu, T.; Huang, H. X.; Huang, X. T.; Huang, Y. B.; Huber, P.; Huo, W.; Hussain, G.; Jaffe, D. E.; Jen, K. L.; Ji, X. L.; Ji, X. P.; Jiao, J. B.; Johnson, R. A.; Jones, D.; Kang, L.; Kettell, S. H.; Khan, A.; Koerner, L. W.; Kohn, S.; Kramer, M.; Kwok, M. W.; Langford, T. J.; Lau, K.; Lebanowski, L.; Lee, J.; Lee, J. H. C.; Lei, R. T.; Leitner, R.; Leung, J. K. C.; Li, C.; Li, D. J.; Li, F.; Li, G. S.; Li, Q. J.; Li, S.; Li, S. C.; Li, W. D.; Li, X. N.; Li, X. Q.; Li, Y. F.; Li, Z. B.; Liang, H.; Lin, C. J.; Lin, G. L.; Lin, S.; Lin, S. K.; Lin, Y.-C.; Ling, J. J.; Link, J. M.; Littenberg, L.; Littlejohn, B. R.; Liu, J. C.; Liu, J. L.; Loh, C. W.; Lu, C.; Lu, H. Q.; Lu, J. S.; Luk, K. B.; Ma, X. B.; Ma, X. Y.; Ma, Y. Q.; Malyshkin, Y.; Martinez Caicedo, D. A.; McDonald, K. T.; McKeown, R. D.; Mitchell, I.; Nakajima, Y.; Napolitano, J.; Naumov, D.; Naumova, E.; Ochoa-Ricoux, J. P.; Olshevskiy, A.; Pan, H.-R.; Park, J.; Patton, S.; Pec, V.; Peng, J. C.; Pinsky, L.; Pun, C. S. J.; Qi, F. Z.; Qi, M.; Qian, X.; Qiu, R. M.; Raper, N.; Ren, J.; Rosero, R.; Roskovec, B.; Ruan, X. C.; Steiner, H.; Sun, J. L.; Tang, W.; Taychenachev, D.; Treskov, K.; Tsang, K. V.; Tse, W.-H.; Tull, C. E.; Viaux, N.; Viren, B.; Vorobel, V.; Wang, C. H.; Wang, M.; Wang, N. Y.; Wang, R. G.; Wang, W.; Wang, X.; Wang, Y. F.; Wang, Z.; Wang, Z.; Wang, Z. M.; Wei, H. Y.; Wen, L. J.; Whisnant, K.; White, C. G.; Wise, T.; Wong, H. L. H.; Wong, S. C. F.; Worcester, E.; Wu, C.-H.; Wu, Q.; Wu, W. J.; Xia, D. M.; Xia, J. K.; Xing, Z. Z.; Xu, J. L.; Xu, Y.; Xue, T.; Yang, C. G.; Yang, H.; Yang, L.; Yang, M. S.; Yang, M. T.; Yang, Y. Z.; Ye, M.; Ye, Z.; Yeh, M.; Young, B. L.; Yu, Z. Y.; Zeng, S.; Zhan, L.; Zhang, C.; Zhang, C. C.; Zhang, H. H.; Zhang, J. W.; Zhang, Q. M.; Zhang, R.; Zhang, X. T.; Zhang, Y. M.; Zhang, Y. M.; Zhang, Y. X.; Zhang, Z. J.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, J.; Zhou, L.; Zhuang, H. L.; Zou, J. H.; Daya Bay Collaboration

    2018-03-01

    Neutrons produced by cosmic ray muons are an important background for underground experiments studying neutrino oscillations, neutrinoless double beta decay, dark matter, and other rare-event signals. A measurement of the neutron yield in the three different experimental halls of the Daya Bay Reactor Neutrino Experiment at varying depth is reported. The neutron yield in Daya Bay's liquid scintillator is measured to be Yn=(10.26 ±0.86 )×10-5 , (10.22 ±0.87 )×10-5 , and (17.03 ±1.22 )×10-5 μ-1 g-1 cm2 at depths of 250, 265, and 860 meters-water-equivalent. These results are compared to other measurements and the simulated neutron yield in Fluka and Geant4. A global fit including the Daya Bay measurements yields a power law coefficient of 0.77 ±0.03 for the dependence of the neutron yield on muon energy.

  14. Automatic sample changer for neutron activation analysis at CDTN, Brazil

    International Nuclear Information System (INIS)

    Aimore Dutra Neto; Oliveira Pelaes, Ana Clara; Jacimovic, Radojko

    2018-01-01

    An automatic sample changer was recently developed and installed in the Neutron Activation Analysis (NAA) Laboratory. The certified reference material BCR-320R, Channel Sediment, was analysed in order to verify the reliability of the results obtained by NAA, k 0 -standardisation method, using this automatic system during the gamma-ray measurement step. The results were compared to those manually obtained. The values pointed out that the automatic sample changer is working properly. This changer will increase the productiveness of the neutron activation technique applied at Nuclear Technology Development Centre, CDTN/CNEN expanding its competitiveness as an analytical technique in relation to other techniques. (author)

  15. Data reduction for neutron scattering from plutonium samples. Final report

    International Nuclear Information System (INIS)

    Seeger, P.A.

    1997-01-01

    An experiment performed in August, 1993, on the Low-Q Diffractometer (LQD) at the Manual Lujan Jr. Neutron Scattering Center (MLNSC) was designed to study the formation and annealing of He bubbles in aged 239 Pu metal. Significant complications arise in the reduction of the data because of the very high total neutron cross section of 239 Pu, and also because the sample are difficult to make uniform and to characterize. This report gives the details of the data and the data reduction procedures, presents the resulting scattering patterns in terms of macroscopic cross section as a function of momentum transfer, and suggests improvements for future experiments

  16. Photoneutron cross sections measurements in {sup 9}Be, {sup 13}C e {sup 17}O with thermal neutron capture gamma-rays; Medidas das secoes de choque de fotoneutrons do {sup 9}Be, {sup 13}C e {sup 17}O com radiacao gama de captura de neutrons termicos

    Energy Technology Data Exchange (ETDEWEB)

    Semmler, Renato

    2006-07-01

    Photoneutron cross sections measurements of {sup 9}Be, {sup 13}C and {sup 17}O have been obtained in the energy interval between 1,6 and 10,8 MeV, using neutron capture gamma-rays with high resolution in energy (3 a 21 eV), produced by 21 target materials, placed inside a tangential beam port, near the core of the IPEN/CNEN-SP IEA-R1 (5 MW) research reactor. The samples have been irradiated inside a 4{pi} geometry neutron detector system 'Long Counter', 520,5 cm away from the capture target. The capture gamma-ray flux was determined by means of the analysis of the gamma spectrum obtained by using a Ge(Li) solid-state detector (EG and G ORTEC, 25 cm{sup 3}, 5%), previously calibrated with capture gamma-rays from a standard target of Nitrogen (Melamine). The neutron photoproduction cross section has been measured for each target capture gamma-ray spectrum (compound cross section). A inversion matrix methodology to solve inversion problems for unfolding the set of experimental compound cross sections, was used in order to obtain the cross sections at specific excitation energy values (principal gamma line energies of the capture targets). The cross sections obtained at the energy values of the principal gamma lines were compared with experimental data reported by other authors, with have employed different gamma-ray sources. A good agreement was observed among the experimental data in this work with reported in the literature. (author)

  17. Nuclear Dependence of the Transverse-Single-Spin Asymmetry for Forward Neutron Production in Polarized p+A Collisions at sqrt[s_{NN}]=200  GeV.

    Science.gov (United States)

    Aidala, C; Akiba, Y; Alfred, M; Andrieux, V; Aoki, K; Apadula, N; Asano, H; Ayuso, C; Azmoun, B; Babintsev, V; Bagoly, A; Bandara, N S; Barish, K N; Bathe, S; Bazilevsky, A; Beaumier, M; Belmont, R; Berdnikov, A; Berdnikov, Y; Blau, D S; Boer, M; Bok, J S; Brooks, M L; Bryslawskyj, J; Bumazhnov, V; Butler, C; Campbell, S; Canoa Roman, V; Cervantes, R; Chi, C Y; Chiu, M; Choi, I J; Choi, J B; Citron, Z; Connors, M; Cronin, N; Csanád, M; Csörgő, T; Danley, T W; Daugherity, M S; David, G; DeBlasio, K; Dehmelt, K; Denisov, A; Deshpande, A; Desmond, E J; Dion, A; Dixit, D; Do, J H; Drees, A; Drees, K A; Dumancic, M; Durham, J M; Durum, A; Elder, T; Enokizono, A; En'yo, H; Esumi, S; Fadem, B; Fan, W; Feege, N; Fields, D E; Finger, M; Finger, M; Fokin, S L; Frantz, J E; Franz, A; Frawley, A D; Fukuda, Y; Gal, C; Gallus, P; Garg, P; Ge, H; Giordano, F; Goto, Y; Grau, N; Greene, S V; Grosse Perdekamp, M; Gunji, T; Guragain, H; Hachiya, T; Haggerty, J S; Hahn, K I; Hamagaki, H; Hamilton, H F; Han, S Y; Hanks, J; Hasegawa, S; Haseler, T O S; He, X; Hemmick, T K; Hill, J C; Hill, K; Hollis, R S; Homma, K; Hong, B; Hoshino, T; Hotvedt, N; Huang, J; Huang, S; Imai, K; Imrek, J; Inaba, M; Iordanova, A; Isenhower, D; Ito, Y; Ivanishchev, D; Jacak, B V; Jezghani, M; Ji, Z; Jiang, X; Johnson, B M; Jorjadze, V; Jouan, D; Jumper, D S; Kang, J H; Kapukchyan, D; Karthas, S; Kawall, D; Kazantsev, A V; Khachatryan, V; Khanzadeev, A; Kim, C; Kim, D J; Kim, E-J; Kim, M; Kim, M H; Kincses, D; Kistenev, E; Klatsky, J; Kline, P; Koblesky, T; Kotov, D; Kudo, S; Kurita, K; Kwon, Y; Lajoie, J G; Lallow, E O; Lebedev, A; Lee, S; Leitch, M J; Leung, Y H; Lewis, N A; Li, X; Lim, S H; Liu, L D; Liu, M X; Loggins, V-R; Lökös, S; Lovasz, K; Lynch, D; Majoros, T; Makdisi, Y I; Makek, M; Malaev, M; Manko, V I; Mannel, E; Masuda, H; McCumber, M; McGaughey, P L; McGlinchey, D; McKinney, C; Mendoza, M; Metzger, W J; Mignerey, A C; Mihalik, D E; Milov, A; Mishra, D K; Mitchell, J T; Mitsuka, G; Miyasaka, S; Mizuno, S; Montuenga, P; Moon, T; Morrison, D P; Morrow, S I M; Murakami, T; Murata, J; Nagai, K; Nagashima, K; Nagashima, T; Nagle, J L; Nagy, M I; Nakagawa, I; Nakagomi, H; Nakano, K; Nattrass, C; Niida, T; Nouicer, R; Novák, T; Novitzky, N; Novotny, R; Nyanin, A S; O'Brien, E; Ogilvie, C A; Orjuela Koop, J D; Osborn, J D; Oskarsson, A; Ottino, G J; Ozawa, K; Pantuev, V; Papavassiliou, V; Park, J S; Park, S; Pate, S F; Patel, M; Peng, W; Perepelitsa, D V; Perera, G D N; Peressounko, D Yu; PerezLara, C E; Perry, J; Petti, R; Phipps, M; Pinkenburg, C; Pisani, R P; Pun, A; Purschke, M L; Radzevich, P V; Read, K F; Reynolds, D; Riabov, V; Riabov, Y; Richford, D; Rinn, T; Rolnick, S D; Rosati, M; Rowan, Z; Runchey, J; Safonov, A S; Sakaguchi, T; Sako, H; Samsonov, V; Sarsour, M; Sato, K; Sato, S; Schaefer, B; Schmoll, B K; Sedgwick, K; Seidl, R; Sen, A; Seto, R; Sexton, A; Sharma, D; Shein, I; Shibata, T-A; Shigaki, K; Shimomura, M; Shioya, T; Shukla, P; Sickles, A; Silva, C L; Silvermyr, D; Singh, B K; Singh, C P; Singh, V; Skoby, M J; Slunečka, M; Smith, K L; Snowball, M; Soltz, R A; Sondheim, W E; Sorensen, S P; Sourikova, I V; Stankus, P W; Stoll, S P; Sugitate, T; Sukhanov, A; Sumita, T; Sun, J; Syed, S; Sziklai, J; Takeda, A; Tanida, K; Tannenbaum, M J; Tarafdar, S; Taranenko, A; Tarnai, G; Tieulent, R; Timilsina, A; Todoroki, T; Tomášek, M; Towell, C L; Towell, R S; Tserruya, I; Ueda, Y; Ujvari, B; van Hecke, H W; Vazquez-Carson, S; Velkovska, J; Virius, M; Vrba, V; Vukman, N; Wang, X R; Wang, Z; Watanabe, Y; Watanabe, Y S; Wong, C P; Woody, C L; Xu, C; Xu, Q; Xue, L; Yalcin, S; Yamaguchi, Y L; Yamamoto, H; Yanovich, A; Yin, P; Yoo, J H; Yoon, I; Yu, H; Yushmanov, I E; Zajc, W A; Zelenski, A; Zharko, S; Zou, L

    2018-01-12

    During 2015, the Relativistic Heavy Ion Collider (RHIC) provided collisions of transversely polarized protons with Au and Al nuclei for the first time, enabling the exploration of transverse-single-spin asymmetries with heavy nuclei. Large single-spin asymmetries in very forward neutron production have been previously observed in transversely polarized p+p collisions at RHIC, and the existing theoretical framework that was successful in describing the single-spin asymmetry in p+p collisions predicts only a moderate atomic-mass-number (A) dependence. In contrast, the asymmetries observed at RHIC in p+A collisions showed a surprisingly strong A dependence in inclusive forward neutron production. The observed asymmetry in p+Al collisions is much smaller, while the asymmetry in p+Au collisions is a factor of 3 larger in absolute value and of opposite sign. The interplay of different neutron production mechanisms is discussed as a possible explanation of the observed A dependence.

  18. Implementation of variance-reduction techniques for Monte Carlo nuclear logging calculations with neutron sources

    NARCIS (Netherlands)

    Maucec, M

    2005-01-01

    Monte Carlo simulations for nuclear logging applications are considered to be highly demanding transport problems. In this paper, the implementation of weight-window variance reduction schemes in a 'manual' fashion to improve the efficiency of calculations for a neutron logging tool is presented.

  19. Radiation-induced conductivity of doped silicon in response to photon, proton and neutron irradiation

    International Nuclear Information System (INIS)

    Kishimoto, N.; Amekura, H.; Plaksin, O.A.; Stepanov, V.A.

    2000-01-01

    The opto-electronic performance of semiconductors during reactor operation is restricted by radiation-induced conductivity (RIC) and the synergistic effects of neutrons/ions and photons. The RICs of Si due to photons, protons and pulsed neutrons have been evaluated, aiming at radiation correlation. Protons of 17 MeV with an ionizing dose rate of 10 3 Gy/s and/or photons (hν=1.3 eV) were used to irradiate impurity-doped Si (2x10 16 B atoms/cm 3 ) at 300 and 200 K. Proton-induced RIC (p-RIC) and photoconductivity (PC) were intermittently detected in an accelerator device. Neutron-induced RIC (n-RIC) was measured for the same Si in a pulsed fast-fission reactor, BARS-6, with a 70-μs pulse of 2x10 12 n/cm 2 (E>0.01 MeV) and a dose rate of up to 6x10 5 Gy/s. The neutron irradiation showed a saturation tendency in the flux dependence at 300 K due to the strong electronic excitation. Normalization of the electronic excitation, including the pulsed regime, gave a fair agreement among the different radiation environments. Detailed comparison among PC, p-RIC and n-RIC is discussed in terms of radiation correlation including the in-pile condition

  20. The polarization of fast neutrons

    International Nuclear Information System (INIS)

    Talov, V.V.

    2000-01-01

    The present work is the review of polarization of fast neutrons and methods of polarization analysis. This also includes information about polarization of fast neutrons from first papers, which described polarization in the D(d,n) 3 He, 7 Li(p,n) 7 Be, and T(p,n) 3 He reactions. (authors)

  1. Investigations of neutron-rich nuclei at the dripline through their analogue states : The cases of $^{10}$Li - $^{10}$Be (T=2) and $^{17}$C - $^{17}$N (T=5/2)

    CERN Multimedia

    2002-01-01

    We propose to study the elastic resonance scattering reactions $^{9}$Li+p and $^{16}$C+p to investigate the energies, spins and parities of the lowest T=2 states in $^{10}$Be and the T=5/2 states in $^{17}$N. These are analogue states of the ground states and first excited states in $^{10}$Li and $^{17}$C.

  2. Scintillating fibre tracking neutron detector

    International Nuclear Information System (INIS)

    Karlsson, Joakim.

    1995-04-01

    A detector for measurements of collimated fluxes of neutrons in the energy range 2-20 MeV is proposed. It utilizes (n.p) elastic scattering in scintillating optical fibres placed in successive orthogonal layers perpendicular to the neutron flux. A test module has been designed, constructed and tested with respect to separation of neutron and gamma events. The pulse height measurements show the feasibility to discriminate between neutron, gamma and background events. Application to measurements of fusion neutrons is considered. 18 refs, 22 figs, 4 tabs

  3. Measurements of the Fe-54 (n,p) Mn-54 Reaction Cross Section in the Neutron Energy Range 2.3-3.8 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Lauber, A; Malmskog, S

    1964-10-15

    We have measured the {sup 54}Fe (n, p) {sup 54}Mn reaction cross section using a surface barrier detector to record the number of protons released in the reaction. The neutron flux was determined by means of a hydrogenous radiator, detecting the scattered protons with the solid state detector, and calculating the number of impinging neutrons from the well known n-p scattering cross section. The {sup 54}Fe (n, p) {sup 54}Mn reaction cross section is found to increase from 25 mb at 2.3 MeV to 208 mb at 3.5 MeV.

  4. Characterizing Scintillator Response with Neutron Time-of-Flight

    Science.gov (United States)

    Palmisano, Kevin; Visca, Hannah; Caves, Louis; Wilkinson, Corey; McClow, Hannah; Padalino, Stephen; Forrest, Chad; Katz, Joe; Sangster, Craig; Regan, Sean

    2017-10-01

    Neutron scintillator diagnostics for ICF can be characterized using the neutron time-of-flight (nTOF) line on Geneseo's 1.7 MV Tandem Pelletron Accelerator. Neutron signals can be differentiated from gamma signals by employing a coincidence method called the associated particle technique (APT). In this measurement, a 2.1 MeV beam of deuterons incident on a deuterated polyethylene target produces neutrons via the d(d,n)3He reaction. A BC-412 plastic scintillator, placed at a scattering angle of 152º, detects 1.76 MeV neutrons in coincidence with the 2.56 MeV 3He ions at an associated angle of 10º. The APT is used to identify the 1.76 MeV neutron while the nTOF line determines its energy. By gating only mono-energetic neutrons, the instrument response function of the scintillator can be determined free from background scattered neutrons and gamma rays. Funded in part by a Grant from the DOE, through the Laboratory for Laser Energetics.

  5. Utilization and facility of neutron activation analysis in HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y S; Chung, Y J; Moon, J H [Korea Atomic Energy Research Institute, P.O.Box 105 Yusong, 305-600, Taejon (Korea, Republic of)

    1998-07-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10{sup 13}-1.6x10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  6. New results from the NA49 experiment on hadron production in p+p and p+C interactions and survey of backward hadrons in p+C collisions

    CERN Document Server

    Makariev, M

    2013-01-01

    Recent results on proton, anti-proton, neutron and charged kaon production in proton-proton and proton, anti-proton, neutron, deuteron and triton production in proton-carbon collisions at 158 GeV/c beam momentum are presented. Data samples of 4.8 million and 385 734 inelastic events in p+p and p+C, respectively, are obtained with the NA49 detector at the CERN SPS accelerator. The charged particles are identified by energy loss measurement in a system of four TPC chambers, while the neutrons are detected in a forward hadronic calorimeter. The data cover a major fraction of the phase space, ranging from 0 to 1.9 GeV in p_T and in Feynman x variable from -0.8 to 0.95 for protons, from -0.2 to 0.3 for anti-protons, from 0.1 to 0.95 for neutrons and from 0 to 0.5 for kaons. The comparison of the results on proton and neutron production in p+p interactions and deep inelastic e+p collisions at HERA reveals an independence of target fragmentation on the projectile type. Using the charged kaon data in p+p collisions a...

  7. Transmutants and its behaviors in heavy irradiated AlN by reactor neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Atobe, Kozo; Tashiro, Tomonori; Honda, Makoto; Fukuoka, Noboru; Matsukawa, Tokuo [Naruto Univ. of Education, Tokushima (Japan). Faculty of Science; Okada, Moritami; Nakagawa, Masuo

    1997-01-01

    Transmutant production effects on the sintered aluminum nitride have been studied by neutron heavy irradiation using X-ray photoelectron spectroscopy analysis. The specimens are irradiated with fast neutrons in the ranges of 1.0x10{sup 17} - 1.2x10{sup 20} n/cm{sup 2}. For high fluences (>10{sup 18} n/cm{sup 2}), XPS observations show Si2s (153.8 eV) and Si2p (103.3 eV) peaks in XPS spectrum. The depth profiles using Ar-ion sputtering and the chemical shift of the peak indicate that {sup 28}Si induced by {sup 27}Al (n,{gamma}) {sup 28}Al reaction and {beta}-decay of {sup 28}Al precipitates near surface as oxidized silicon. (author)

  8. Neonatal and maternal outcomes of successful manual rotation to correct malposition of the fetal head; A retrospective and prospective observational study.

    Directory of Open Access Journals (Sweden)

    Nicola Tempest

    Full Text Available To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation.Prospective and retrospective observational study.Delivery suite in a tertiary referral teaching hospital in England.A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006-2013.Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section.Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml and obstetric anal sphincter injury.Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346 of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349 shoulder dystocia, 2% (7/349 massive obstetric haemorrhage and 1.7% (6/349 obstetric anal sphincter injury, similar to other methods of rotational births.Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth.

  9. Report of the advisory group meeting on optimal use of accelerator-based neutron generators

    International Nuclear Information System (INIS)

    1998-01-01

    During the past 20 to 25 years, the IAEA has provided a number of laboratories in the developing member states with neutron generators. These neutron generators were originally supplied for the primary purpose of neutron activation analysis. In order to promote the optimal use of these machines, a meeting was held in 1996, resulting in a technical document manual for the upgrading and troubleshooting of neutron generators. The present meeting is a follow-up to that earlier meeting. There are several reasons why some neutron generators are not fully utilized. These include lack of infrastructure, such as an appropriate shielded building and loss of adequately trained technical and academic personnel. Much of the equipment is old and lacking spare parts, and in a few cases there is a critical lack of locally available knowledge and experience in accelerator technology. The report contains recommendations for dealing with these obstacles

  10. SU-G-IeP4-04: DD-Neutron Source Collimation for Neutron Stimulated Emission Computed Tomography: A Monte Carlo Simulation Study

    Energy Technology Data Exchange (ETDEWEB)

    Fong, G; Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, North Carolina (United States)

    2016-06-15

    Purpose: To optimize collimation and shielding for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact clinical neutron imaging system. The envisioned application is cancer diagnosis through Neutron Stimulated Emission Computed Tomography (NSECT). Methods: Collimator designs were tested with an isotropic 2.5 MeV neutron source through GEANT4 simulations. The collimator is a 52×52×52 cm{sup 3} polyethylene block coupled with a 1 cm lead sheet in sequence. Composite opening was modeled into the collimator to permit passage of neutrons. The opening varied in shape (cylindrical vs. tapered), size (1–5 cm source-side and target-side openings) and aperture placements (13–39 cm from source-side). Spatial and energy distribution of neutrons and gammas were tracked from each collimator design. Parameters analyzed were primary beam width (FWHM), divergence, and efficiency (percent transmission) for different configurations of the collimator. Select resultant outputs were then used for simulated NSECT imaging of a virtual breast phantom containing a 2.5 cm diameter tumor to assess the effect of the collimator on spatial resolution, noise, and scan time. Finally, composite shielding enclosure made of polyethylene and lead was designed and evaluated to block 99.99% of neutron and gamma radiation generated in the system. Results: Analysis of primary beam indicated the beam-width is linear to the aperture size. Increasing source-side opening allowed at least 20% more neutron throughput for all designs relative to the cylindrical openings. Maximum throughput for all designs was 364% relative to cylindrical openings. Conclusion: The work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-defined collimated neutron beam that can be used to image samples of interest with millimeter resolution. Balance in output efficiency, noise reduction, and scan

  11. SU-G-IeP4-04: DD-Neutron Source Collimation for Neutron Stimulated Emission Computed Tomography: A Monte Carlo Simulation Study

    International Nuclear Information System (INIS)

    Fong, G; Kapadia, A

    2016-01-01

    Purpose: To optimize collimation and shielding for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact clinical neutron imaging system. The envisioned application is cancer diagnosis through Neutron Stimulated Emission Computed Tomography (NSECT). Methods: Collimator designs were tested with an isotropic 2.5 MeV neutron source through GEANT4 simulations. The collimator is a 52×52×52 cm"3 polyethylene block coupled with a 1 cm lead sheet in sequence. Composite opening was modeled into the collimator to permit passage of neutrons. The opening varied in shape (cylindrical vs. tapered), size (1–5 cm source-side and target-side openings) and aperture placements (13–39 cm from source-side). Spatial and energy distribution of neutrons and gammas were tracked from each collimator design. Parameters analyzed were primary beam width (FWHM), divergence, and efficiency (percent transmission) for different configurations of the collimator. Select resultant outputs were then used for simulated NSECT imaging of a virtual breast phantom containing a 2.5 cm diameter tumor to assess the effect of the collimator on spatial resolution, noise, and scan time. Finally, composite shielding enclosure made of polyethylene and lead was designed and evaluated to block 99.99% of neutron and gamma radiation generated in the system. Results: Analysis of primary beam indicated the beam-width is linear to the aperture size. Increasing source-side opening allowed at least 20% more neutron throughput for all designs relative to the cylindrical openings. Maximum throughput for all designs was 364% relative to cylindrical openings. Conclusion: The work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-defined collimated neutron beam that can be used to image samples of interest with millimeter resolution. Balance in output efficiency, noise reduction, and scan time

  12. A Study of the Angular Distributions of Neutrons from the {sup 9}Be (p,n) {sup 9}B Reaction at Low Proton Energies

    Energy Technology Data Exchange (ETDEWEB)

    Antolkovic, B; Holmqvist, B; Wiedling, T

    1964-10-15

    The angular distributions of neutrons from the reaction {sup 9}Be (p, n) {sup 9}B have been studied at the proton energies 2.300, 2.335, 2.389, and 2.560 MeV. Time-of-flight techniques have been used. The angular distribution measurements show remarkable differences compared to earlier published results using long-counters as detectors. The new results are ascribed to the different experimental methods. By using time-of-flight techniques it has been possible to eliminate disturbing influences from neutrons obtained from the {sup 9}Be (p,p'n) {sup 8}Be reaction which has a lower reaction threshold than the {sup 9}Be (p, n) {sup 9}B reaction as well as other Be-p-reactions emitting neutrons. The experimental distribution at 2.30 MeV has been compared with the simplified theories for direct interaction processes developed by Satchler and Rodberg. It is shown that Rodberg's proposal of using optical model wave functions describes the experiment better than Satchler's original theory. However, a good fitting leads to a nuclear radius as well as an optical potential which is appreciably smaller than ordinarily obtained in scattering experiments.

  13. Magnetic excitations in Ho2Co17 and Ho2Fe17

    International Nuclear Information System (INIS)

    Clausen, K.N.

    1981-01-01

    The low energy part ( 2 Co 17 and Ho 2 Fe 17 have been measured along the three high symmetry directions at a temperature of 4.2 K, using the inelastic neutron scattering technique. The resulting magnon dispersion relations have been interpreted using linear spin wave theory with a Hamiltonian including single ion crystal field anisotropy and isotropic exchange between spatially well localized spins. The R 2 T 17 structure contains two different Ho sites, with the same point symmetry, and from the spin wave results it was concluded that the crystal field anisotropy of the two Ho sites in both Ho 2 Co 17 and Ho 2 Fe 17 were identical. The deduced crystal field parameters for Ho 2 Fe 17 were slightly larger than for Ho 2 Co 17 , and the parameters were of the same order of magnitude as for pure Ho. For Ho 2 Fe 17 the Fe-Fe exchange was found to be anisotropic, and for both compounds the magnetic ordering temperatures of 1178 K for Ho 2 Co 17 and 335 K for Ho 2 Fe 17 were determined by the strong positive 3d-3d exchange. (Auth.)

  14. Segmented detector for recoil neutrons in the p(γ, n)π+ reaction

    International Nuclear Information System (INIS)

    Korkmaz, E.; O'Rielly, G.V.; Hutcheon, D.A.; Feldman, G.; Jordan, D.; Kolb, N.R.; Pywell, R.E.; Retzlaff, G.A.; Sawatzky, B.D.; Skopik, D.M.; Vogt, J.M.; Cairns, E.; Giesen, U.; Holm, L.; Opper, A.K.; Rozon, F.M.; Soukup, J.

    1999-01-01

    A segmented neutron detector has been constructed and used for recoil neutron (6-13 MeV) measurements of the reaction γp→nπ + very close to threshold. BC-505 liquid scintillator was used to allow pulse shape discrimination between neutrons and photons. A measurement of the absolute efficiency of the detector was performed using stopped pions in the reaction π - p→nγ. Results of the efficiency calibration are compared to a Monte Carlo simulation. (author)

  15. Measurement of the Decay of Thermal Neutrons in Water Poisoned with the Non-1/v Neutron Absorber Cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, L G; Moeller, E

    1968-01-15

    Measurements have been made of the decay constant of thermal neutrons in water poisoned with the non-1/v absorber cadmium. An experimental method has been used in which proper spatial integration of the neutron flux enables data, representative of the infinite medium to be accumulated without waiting for the establishment of a fundamental mode distribution. The change in effective cross section with concentration of the dissolved cadmium, d{sigma}{sub eff}/dN. has been determined for infinite medium at 20 deg C. Two- and three parameter fits of the decay constant yield -(0.32 {+-} 0.09) x 10{sup -17} barn cm{sup 3} and -(0.47 {+-} 0.10) x 10{sup -17} barn cm{sup 3}, respectively. Earlier published measurements have resulted in two to five times larger values, whereas a published calculated value of Nelkin's model is - 0.33 x 10{sup -17} barn cm{sup 3}.

  16. Measurement of the Decay of Thermal Neutrons in Water Poisoned with the Non-1/v Neutron Absorber Cadmium

    International Nuclear Information System (INIS)

    Larsson, L.G.; Moeller, E.

    1968-01-01

    Measurements have been made of the decay constant of thermal neutrons in water poisoned with the non-1/v absorber cadmium. An experimental method has been used in which proper spatial integration of the neutron flux enables data, representative of the infinite medium to be accumulated without waiting for the establishment of a fundamental mode distribution. The change in effective cross section with concentration of the dissolved cadmium, dσ eff /dN. has been determined for infinite medium at 20 deg C. Two- and three parameter fits of the decay constant yield -(0.32 ± 0.09) x 10 -17 barn cm 3 and -(0.47 ± 0.10) x 10 -17 barn cm 3 , respectively. Earlier published measurements have resulted in two to five times larger values, whereas a published calculated value of Nelkin's model is - 0.33 x 10 -17 barn cm 3

  17. Secondary standard neutron detector for measuring total reaction cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Gabbard, F.

    1975-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron-production cross sections. The detector consists of a polyethylene sphere of 24'' diameter in which 8- 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies, from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p,n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p,n) 51 Cr and 57 Fe(p,n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for measurement of total neutron yields from neutron producing reactions such as 23 Na(p,n) 23 Mg are given

  18. Characterizing ICF Neutron Diagnostics on the nTOF line at SUNY Geneseo

    Science.gov (United States)

    Simone, Angela; Padalino, Stephen; Turner, Ethan; Ginnane, Mary Kate; Dubois, Natalie; Fletcher, Kurtis; Giordano, Michael; Lawson-Keister, Patrick; Harrison, Hannah; Visca, Hannah; Sangster, Craig; Regan, Sean

    2014-10-01

    Charged particle beams from the Geneseo 1.7 MV tandem Pelletron accelerator produce nuclear reactions that emit neutrons in the range of 0.5 to 17.9 MeV via the d(d,n)3He and 11B(d,n)12C reactions. The neutron energy and flux can be adjusted by controlling the accelerator beam current and potential. This adjustable neutron source makes it possible to calibrate ICF and HEDP neutron scintillator diagnostics. However, gamma rays which are often present during an accelerator-based calibration are difficult to differentiate from neutron signals in scintillators. To identify neutrons from gamma rays and to determine their energy, a permanent neutron time-of-flight (nTOF) line is being constructed. By detecting the scintillator signal in coincidence with an associated charged particle (ACP) produced in the reaction, the identity of the neutron can be known and its energy determined by time of flight. Using a 100% efficient surface barrier detector to count the ACPs, the absolute efficiency of the scintillator as a function of neutron energy can be determined. This is done by determining the ratio of the ACP counts in the singles spectrum to coincidence counts for matched solid angles of the SBD and scintillator. Funded in part by a LLE contract through the DOE.

  19. 106-17 Telemetry Standards Chapter 1

    Science.gov (United States)

    2017-07-01

    Telemetry Standards, RCC Standard 106-17 Chapter 1, July 2017 1-1 CHAPTER 1 Introduction The Telemetry Standards address the here-to-date...for Federal Radio Frequency Management . Copies of that manual may be obtained from: Executive Secretary, Interdepartmental Radio Advisory Committee

  20. Device fabrication, characterization, and thermal neutron detection response of LiZnP and LiZnAs semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Montag, Benjamin W., E-mail: bmontag@ksu.edu; Ugorowski, Philip B.; Nelson, Kyle A.; Edwards, Nathaniel S.; McGregor, Douglas S.

    2016-11-11

    Nowotny-Juza compounds continue to be explored as candidates for solid-state neutron detectors. Such a device would have greater efficiency, in a compact form, than present day gas-filled {sup 3}He and {sup 10}BF{sub 3} detectors. The {sup 6}Li(n,t){sup 4}He reaction yields a total Q-value of 4.78 MeV, larger than {sup 10}B, an energy easily identified above background radiations. Hence, devices fabricated from semiconductor compounds having either natural Li (nominally 7.5% {sup 6}Li) or enriched {sup 6}Li (usually 95% {sup 6}Li) as constituent atoms may provide a material for compact high efficiency neutron detectors. Starting material was synthesized by preparing equimolar portions of Li, Zn, and As sealed under vacuum (10{sup −6} Torr) in quartz ampoules lined with boron nitride and subsequently reacted in a compounding furnace [1]. The raw synthesized material indicated the presence high impurity levels (material and electrical property characterizations). A static vacuum sublimation in quartz was performed to help purify the synthesized material [2,3]. Bulk crystalline samples were grown from the purified material [4,5]. Samples were cut using a diamond wire saw, and processed into devices. Bulk resistivity was determined from I–V curve measurements, ranging from 10{sup 6}–10{sup 11} Ω cm. Devices were characterized for sensitivity to 5.48 MeV alpha particles, 337 nm laser light, and neutron sensitivity in a thermal neutron diffracted beam at the Kansas State University TRIGA Mark II nuclear reactor. Thermal neutron reaction product charge induction was measured with a LiZnP device, and the reaction product spectral response was observed. - Highlights: • Devices were fabricated from in-house synthesized and purified LiZnAs and LiZnP. • Devices ranged in bulk resistivity from 10{sup 6}–10{sup 11} Ω cm. • Devices showed sensitivity to 5.48 MeV alpha particles. • Devices were characterized with a 337 nm laser light. • Devices were evaluated

  1. Manual Hydraulic Structures

    NARCIS (Netherlands)

    Molenaar, W.F.; Voorendt, M.Z.

    This manual is the result of group work and origins in Dutch lecture notes that have been used since long time. Amongst the employees of the Hydraulic Engineering Department that contributed to this work are dr.ir. S. van Baars, ir.K.G.Bezuijen, ir.G.P.Bourguignon, prof.ir.A.Glerum,

  2. 17,20β-P and cortisol are the main in vitro metabolites of 17-hydroxy-progesterone produced by spermiating testes of Micropogonias furnieri (Desmarest, 1823 (Perciformes: Sciaenidae

    Directory of Open Access Journals (Sweden)

    Denise Vizziano Cantonnet

    Full Text Available The aim was to investigate the major C21 steroids produced by spermiating white croaker Micropogonias furnieri (Sciaenidae in order to establish the potential mediator of gamete maturation in males of this species. The testes steroid production at the spawning season was identified incubating the 3H-17-hydroxy-4-pregnene-3,20-dione precursor through thin layer chromatography, high pressure liquid chromatography, enzymatic oxydation, acetylation and immunochemistry analyses. 17,20β-Dihydroxy-4-pregnen-3-one (17,20β-P and 11β,17,21-Trihydroxy-4-pregnene-3,20-dione (cortisol were the main metabolites produced. Contrary to what we expected, 17,20β,21-Trihydroxy-4-pregnen-3-one was not detected. Circulating levels of 17,20β-P were undetectable in immature testes and in those at the first spermatogenesis stages, while a clear increase was observed during the whole spermatogenesis and spermiation phases (from undetectable to 1047 pg mL-1. In vitro studies together with plasma detection suggest that 17,20β-P is a good steroid candidate involved in M. furnieri testes maturation. The role of cortisol during late phases of testes development needs further studies.

  3. Control program of the neutron four-circle-diffractometer P32 at the SILOE reactor/CEN Grenoble

    International Nuclear Information System (INIS)

    Guth, H.; Paulus, H.; Reimers, W.; Heger, G.

    1983-09-01

    The four-circle diffractometer P32 for elastic neutron scattering on single crystals was installed at the SILOE reactor/CEN Grenoble in 1981. The control program, presented here, is a new update of the former program versions used at the FR2 reactor/Kernforschungszentrum Karlsruhe. Important improvements concerning reliability and handling of the diffractometer are added. (orig.) [de

  4. Control program of the neutron four-circle-diffractometer P110 at the ORPHEE reactor/CEN Saclay

    International Nuclear Information System (INIS)

    Guth, H.; Paulus, H.; Reimers, W.; Heger, G.

    1984-05-01

    The four-circle diffractometer P110 for elastic neutron scattering on single crystals was installed at the ORPHEE reactor/CEN Saclay in 1982. The control progam, presented here, is a new update of the former program versions used at the FR2 reactor. Important improvements concerning reliability and handling of the diffractometer are added. (orig./HP) [de

  5. Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments

    International Nuclear Information System (INIS)

    Lee, K.W.; Sheu, R.J.

    2015-01-01

    High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with 252 Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing 252 Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6-8 extended-range sphere versus the 6'' standard sphere). (authors)

  6. A final report for Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons

    CERN Document Server

    Vernon, S M

    1999-01-01

    This SBIR Phase I developed neutron detectors made FR-om gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the FR-ont surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed FR-om a layer of Al sub x Ga sub 1 sub - sub x As. Schottky-barrier diodes formed FR-om the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge is over 90%. The lowest dark current measured is 1 x 10 sup - sup 1 sup 2 amps at -1 V o...

  7. Anisotropy of neutron sources of Neutron Metrology Laboratory, IRD, Brazil

    International Nuclear Information System (INIS)

    Silva, A.C.F.; Silva, F.S.; Leite, S.P.; Creazolla, P.G; Patrão, K.C.S.; Fonseca, E.S. da; Fernandes, S.S.; Pereira, W.W.

    2017-01-01

    The anisotropy measurements have as main objective to define the emission of the radiation by different angles of an encapsulated neutron source. The measurements were performed using a Long Accuracy Counter (PLC) Detector in the Low Dispersion Room of the LNMRI / IRD with different neutron sources. Each measurement was made using a support for the source, emulated through an arduino system to rotate it. The carrier is marked with a variation of 5 °, ranging from 0 ° to 360 °, for the work in question only half, 0 ° to 180 ° is used for a total of nineteen steps. In this paper three sources of "2"4"1AmBe (α, n) 5.92 GBq (16 Ci) were used, neutron sources having the following dimensions: 105 mm in height and 31 mm in diameter. The PLC was positioned at a distance of 2 meters from the neutron source and has a radius of 15 cm for the detection area. The anisotropy factor of the "2"4"1AmBe source was 17%. The results in this work will focus mainly on the area of radioprotection and studies that will improve the process of routine measurements in laboratories and instrument calibrations. (author)

  8. Space dependent neutron slowing and thermalization in monatomic hydrogen gas in the P-1 approximation

    International Nuclear Information System (INIS)

    Musazay, M.S.

    1981-01-01

    A solution to the space and energy dependent neutron transport equation in the framework of the consistent P-1 approximation is sought. The transport equation for thermal neutrons in a moderator of 1/v absorption and constant scattering cross section is changed into a set of coupled partial differential equations. The space dependent part is removed by assuming a cosine shaped flux due to a cosine shaped source at a very high energy. The resulting set of strongly coupled ordinary differential equations is decoupled by assuming expansion of collision density in the powers of a leakage parameter whose coefficients are energy and absorption dependent. These energy dependent coefficients are solutions of a set of weakly coupled differential equations. Series solutions to these differential equations in powers of epsilon and 1/epsilon, where epsilon = E/kT, E being the neutron energy and kT the moderator temperature in units of energy, are found. The properties of these solutions are studied extensively. Absorption appears as a parameter in the coefficients of the series. The difficulties arising in choosing the correct form of the asymptotic solutions are resolved by comparing slowing and thermalization. The limitations on the size of the slab and on the range of absorption are included in the analysis

  9. Photo-neutron cross sections for unstable neutron-rich oxygen isotopes

    International Nuclear Information System (INIS)

    Leistenschneider, A.; Aumann, T.; Boretzky, K.

    2001-05-01

    The dipole response of stable and unstable neutron-rich oxygen nuclei of masses A = 17 to A = 22 has been investigated experimentally utilizing electromagnetic excitation in heavy-ion collisions at beam energies around 600 MeV/nucleon. A kinematically complete measurement of the neutron decay channel in inelastic scattering of the secondary beam projectiles from a Pb target was performed. Differential electromagnetic excitation cross sections dσ/dE were derived up to 30 MeV excitation energy. In contrast to stable nuclei, the deduced dipole strength distribution appears to be strongly fragmented and systematically exhibits a considerable fraction of low-lying strength, exhausting up to 12% of the energy-weighted dipole sum rule at excitation energies below 15 MeV. (orig.)

  10. Angular measurement of the energy distribution of neutrons from the thick target 7Li(p,n)7Be source

    International Nuclear Information System (INIS)

    Rose, A.

    1981-11-01

    The energy spectrum of neutrons emitted from a thick lithium target bombarded by protons has been measured as a function of neutron angle of emission. The measurements were done at proton energies up to 2.8 MeV and at 30 deg. intervals in the range 0 to 120 deg. using proportional detectors with gas fillings of hydrogen and methane. A review is given of papers published on the 7 Li(p,n) 7 Be reactions at 0 deg.; where applicable, comparisons are made with the present results

  11. Neutron fragmentation in the reaction pn to pX at 19 GeV/c

    CERN Document Server

    Bakken, V; Lundborg, P; Makela, J; Pimiä, M; Selldén, B; Sundell, E; Tuominiemi, J

    1979-01-01

    Data on the reaction pn to pX are extracted from a pd experiment in the CERN 2 m DBC at 10 GeV/c. The cross-section for neutron fragmentation events with mod t mod <1 (GeV/c)/sup 2/ determined and compared with data at high energies at fixed M/sub x//sup 2//s and t. The cross-section can be described with the triple-Regge formula taking into account only the pion exchange contributions, i.e. the pi pi P and pi pi R terms. A leading-particle effect consistent with the pion exchange model is observed in the longitudinal-momentum distribution of the negative pions in the final state of the reaction pn to pX, when transformed to the rest frame of the recoiling system X. (10 refs).

  12. Development of precision elliptic neutron-focusing supermirror.

    Science.gov (United States)

    Hosobata, Takuya; Yamada, Norifumi L; Hino, Masahiro; Yamagata, Yutaka; Kawai, Toshihide; Yoshinaga, Hisao; Hori, Koichiro; Takeda, Masahiro; Takeda, Shin; Morita, Shin-Ya

    2017-08-21

    This paper details methods for the precision design and fabrication of neutron-focusing supermirrors, based on electroless nickel plating. We fabricated an elliptic mirror for neutron reflectometry, which is our second mirror improved from the first. The mirror is a 550-millimeter-long segmented mirror assembled using kinematic couplings, with each segment figured by diamond cutting, polished using colloidal silica, and supermirror coated through ion-beam sputtering. The mirror was evaluated with neutron beams, and the reflectivity was found to be 68-90% at a critical angle. The focusing width was 0.17 mm at the full width at half maximum.

  13. Promising Tools in Prostate Cancer Research: Selective Non-Steroidal Cytochrome P450 17A1 Inhibitors

    Science.gov (United States)

    Bonomo, Silvia; Hansen, Cecilie H.; Petrunak, Elyse M.; Scott, Emily E.; Styrishave, Bjarne; Jørgensen, Flemming Steen; Olsen, Lars

    2016-07-01

    Cytochrome P450 17A1 (CYP17A1) is an important target in the treatment of prostate cancer because it produces androgens required for tumour growth. The FDA has approved only one CYP17A1 inhibitor, abiraterone, which contains a steroidal scaffold similar to the endogenous CYP17A1 substrates. Abiraterone is structurally similar to the substrates of other cytochrome P450 enzymes involved in steroidogenesis, and interference can pose a liability in terms of side effects. Using non-steroidal scaffolds is expected to enable the design of compounds that interact more selectively with CYP17A1. Therefore, we combined a structure-based virtual screening approach with density functional theory (DFT) calculations to suggest non-steroidal compounds selective for CYP17A1. In vitro assays demonstrated that two such compounds selectively inhibited CYP17A1 17α-hydroxylase and 17,20-lyase activities with IC50 values in the nanomolar range, without affinity for the major drug-metabolizing CYP2D6 and CYP3A4 enzymes and CYP21A2, with the latter result confirmed in human H295R cells.

  14. A weight limit emerges for neutron stars

    Science.gov (United States)

    Cho, Adrian

    2018-02-01

    Astrophysicists have long wondered how massive a neutron star—the corpse of certain exploding stars—could be without collapsing under its own gravity to form a black hole. Now, four teams have independently deduced a mass limit for neutron stars of about 2.2 times the mass of the sun. To do so, all four groups analyzed last year's blockbuster observations of the merger of two neutron stars, spied on 17 September 2017 by dozens of observatories. That approach may seem unpromising, as it might appear that the merging neutron stars would have immediately produced a black hole. However, the researchers argue that the merger first produced a spinning, overweight neutron star momentarily propped up by centrifugal force. They deduce that just before it collapsed, the short-lived neutron star had to be near the maximum mass for one spinning as a solid body. That inference allowed them to use a scaling relationship to estimate the maximum mass of a nonrotating, stable neutron star, starting from the total mass of the original pair and the amount of matter spewed into space.

  15. Study on neutron interactions with protons and carbon nuclei at p=4.2 GeV/c

    International Nuclear Information System (INIS)

    Bekmirzaev, R.N.; Muminov, M.M.; Sultanov, M.U.; Grishina, O.V.; Dolejsi, J.; Tas, P.; Trka, Z.

    1988-01-01

    The production of neutrons with p=4.2 GeV/c in d(C 3 H 8 ) collisions and their interaction with proton and carbon nuclei are studied. The experimental material has been obtained using the 2m propane bubble chamber irradiated by deuterons with p=4.2 GeV/c per nucleon at the Dubna synchrophasotron, JINR. The data on multiplicity and momentum characteristics of secondary particles in np and nC interactions compared with the calculations on the LUND model are obtained

  16. Measurement of the Electric Form Factor of the Neutron through d-vector(e-vector, e'n)p

    International Nuclear Information System (INIS)

    Hongguo Zhu; Abdellah Ahmidouch; Anklin, H.; Arenhoevel, H.; Chris Armstrong; C. Bernet; Werner Boeglin; Herbert Breuer; Paul Brindza; D. Brown; S. Bueltmann; Roger Carlini; Nicholas Chant; Anthony Cowley; Donald Crabb; Samuel Danagoulian; D. B. Day; Tom Eden; Rolf Ent; Yusuf Farah; Renee Fatimi; Kenneth Garrow; Chris Harris; Markus Hauger; A. Honegger; J. Jourdan; M. Kaufmann; Mahbub Khandaker; Gunther Kubon; Jechiel Lichtenstadt; Richard Lindgren; Robert Lourie; Allison Lung; David Mack; Sudhir Malik; Pete Markowitz; Kenneth McFarlane; Paul McKee; Dustin McNulty; Geoffrey Milanovich; Joseph Mitchell; Hamlet Mkrtchyan; M. Muehlbauer; Thomas Petitjean; Yelena Prok; Daniela Rohe; Emmanuel Rollinde; Oscar Rondon-Aramayo; Philip Roos; Reyad Sawafta; Ingo Sick; C. Smith; Tim Southern; Michael Steinacher; Stepan Stepanyan; Vardan Tadevosyan; Raphael Tieulent; Al Tobias; Bill Vulcan; Glen Warren; H. Woehrle; Stephen Wood; Chen Yan; Marko Zeier; Jianguo Zhao; Beni Zihlmann

    2001-01-01

    We report the first measurement using a solid polarized target of the neutron electric form factor G n E via d-vector(e-vector, e'n)p. G n E was determined from the beam-target asymmetry in the scattering of longitudinally polarized electrons from polarized deuterated ammonia ( 15 ND 3 ). The measurement was performed in Hall C at Thomas Jefferson National Accelerator Facility in quasifree kinematics with the target polarization perpendicular to the momentum transfer. The electrons were detected in a magnetic spectrometer in coincidence with neutrons in a large solid angle segmented detector. We find G n E = 0.04632±0.00616(stat)±0.00341(syst) at Q 2 = 0.495 (GeV/c) 2

  17. The use of contrast variation in small angle neutron scattering on the low-Q diffractometer at the Manuel Lujuan Jr. Neutron Scattering Center at Los Alamos National Laboratory (LANSCE)

    International Nuclear Information System (INIS)

    Spaccavento, J.

    1993-01-01

    As a Department of Energy Teacher Research Associate at Los Alamos National Laboratory this past summer, the author was given the opportunity to exit the class-room and enter the world of intense scientific research for an eight week period. In this paper the author briefly describes the Manual Lujan Jr. Neutron Scattering Center at Los Alamos, then focuses specifically on the Low-Q Diffractometer which was the instrument he worked on. The author details one specific experimental technique namely open-quotes Contrast Variation,close quotes and closes by briefly presenting several other interesting applications of neutron scattering

  18. Cold neutron interferometry and its application. 2. Coherency and cold neutron spin interferometry

    International Nuclear Information System (INIS)

    Achiwa, Norio; Ebisawa, Toru

    1998-03-01

    The second workshop entitled 'Interference studies and cold neutron spin interferometry' was held on 10 and 11 March 1998 at KUR (Kyoto University Research Reactor Institute, Kumatori). Cold neutron spin interferometry is a new field. So it is very important for its development to learn the studies of X-ray and neutron optics which are rapidly developing with long history. In the workshop, the issues related to interference were reviewed such as experimental studies on cold neutron spin interferometry, theoretical and experimental approach on tunneling time, interference experiments by neutrons and its application, interference studies using synchrotron radiation, topics on silicon interferometry and quantum measurement problem and cold neutron interference experiment related to quantum measurement problem. The 8 of the presented papers are indexed individually. (J.P.N.)

  19. Measurement of the lunar neutron density profile

    International Nuclear Information System (INIS)

    Woolum, D.S.; Burnett, D.S.; Furst, M.; Weiss, J.R.

    1975-01-01

    An in situ measurement of the lunar neutron density from 20 to 400 g cm -2 depth below the lunar surface was made by the Apollo 17 Lunar Neutron Probe Experiment (LNPE) using particle tracks produced by the 10 B (n,α) 7 Li reaction. Both the absolute magnitude and the depth profile of the neutron density are in good agreement with theoretical calculations by Lingenfelter, Canfield, and Hampel. However, relatively small deviations between experiment and theory in the effect of Cd absorption on the neutron density and in the relative 149 Sm to 157 Gd capture rates reported previously (Russ et al., 1972) imply that the true lunar 157 Gd capture rate is about one half of that calculated theoretically. (Auth.)

  20. EXFOR Manual. Center-to-Center Exchange Format. Version 89-1

    International Nuclear Information System (INIS)

    McLane, V.

    1989-09-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. EXFOR is a database with several million data records containing the world's experimental nuclear reaction data induced by neutrons, photons or charged particles. Data retrievals can be obtained from the IAEA Nuclear Data Section (NDS) or from one of the co-operating data centers whose names and addresses can be found inside the manual. Their contributions and co-operative efforts are gratefully acknowledged. (author). Refs

  1. Estimation of subcriticality by neutron source multiplication method

    International Nuclear Information System (INIS)

    Sakurai, Kiyoshi; Suzaki, Takenori; Arakawa, Takuya; Naito, Yoshitaka

    1995-03-01

    Subcritical cores were constructed in a core tank of the TCA by arraying 2.6% enriched UO 2 fuel rods into nxn square lattices of 1.956 cm pitch. Vertical distributions of the neutron count rates for the fifteen subcritical cores (n=17, 16, 14, 11, 8) with different water levels were measured at 5 cm interval with 235 U micro-fission counters at the in-core and out-core positions arranging a 252 C f neutron source at near core center. The continuous energy Monte Carlo code MCNP-4A was used for the calculation of neutron multiplication factors and neutron count rates. In this study, important conclusions are as follows: (1) Differences of neutron multiplication factors resulted from exponential experiment and MCNP-4A are below 1% in most cases. (2) Standard deviations of neutron count rates calculated from MCNP-4A with 500000 histories are 5-8%. The calculated neutron count rates are consistent with the measured one. (author)

  2. Pulsed neutron generator for logging

    International Nuclear Information System (INIS)

    Thibideau, F.D.

    1977-01-01

    A pulsed neutron generator for uranium logging is described. This generator is one component of a prototype uranium logging probe which is being developed by SLA to detect, and assay, uranium by borehole logging. The logging method is based on the measurement of epithermal neutrons resulting from the prompt fissioning of uranium from a pulsed source of 17.6 MeV neutrons. An objective of the prototype probe was that its diameter not exceed 2.75 inches, which would allow its use in conventional rotary drill holes of 4.75-inch diameter. This restriction limited the generator to a maximum 2.375-inch diameter. The performance requirements for the neutron generator specified that it operate with a nominal output of 5 x 10 6 neutrons/pulse at up to 100 pulses/second for a one-hour period. The development of a neutron generator meeting the preliminary design goals was completed and two prototype models were delivered to SLA. These two generators have been used by SLA to log a number of boreholes in field evaluation of the probe. The results of the field evaluations have led to the recommendation of several changes to improve the probe's operation. Some of these changes will require additional development effort on the neutron generator. It is expected that this work will be performed during 1977. The design and operation of the first prototype neutron generators is described

  3. Transient and chronic neurological complications of fast neutron radiation for adenocarcinoma of the prostate

    International Nuclear Information System (INIS)

    Russell, K.J.; Laramore, G.E.; Wiens, L.W.; Griffeth, J.T.; Koh, W.J.; Griffin, B.R.; Austin-Seymour, M.M.; Griffin, T.W.

    1990-01-01

    The records of 132 patients participating in clinical trials using fast neutron (n = 94), mixed neutron and photon (n = 16), or conventional photon (n = 22) irradiation for primary management of prostatic cancer were retrospectively reviewed to assess treatment-related neurological complications. With a median follow-up of 14 months (range 1 to 101 months), 31/132 patients (26 neutron, 3 mixed beam, 2 photon) have experienced either sciatica beginning during or shortly after treatment, or diminished bladder or bowel continence that developed at a median time of 6.5 months following treatment. Sciatica responded to oral steroids and was usually self-limited, whereas sphincter dysfunction appears to be permanent. Pre-treatment risk factors for complications included a history of hypertension, diabetes, cigarette smoking or peripheral vascular disease, with 81% of affected patients having one or more risk factors compared witn 55% of unaffected patients (p = 0.01). Seven patients have moderate (5) or severe (2) residual problems, all in the cohorts receiving neutrons (6/7) or mixed beam therapy (1/7). (author). 31 refs.; 5 tabs

  4. Transient and chronic neurological complications of fast neutron radiation for adenocarcinoma of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Russell, K.J.; Laramore, G.E.; Wiens, L.W.; Griffeth, J.T.; Koh, W.J.; Griffin, B.R.; Austin-Seymour, M.M.; Griffin, T.W. (Washington Univ., Seattle, WA (USA). Lab. of Radiation Ecology); Krieger, J.N. (Washington University, Seattle (USA). Department of Urology); Davis, L.W. (Albert Einstein Coll. of Medicine, Bronx, NY (USA))

    1990-07-01

    The records of 132 patients participating in clinical trials using fast neutron (n = 94), mixed neutron and photon (n = 16), or conventional photon (n = 22) irradiation for primary management of prostatic cancer were retrospectively reviewed to assess treatment-related neurological complications. With a median follow-up of 14 months (range 1 to 101 months), 31/132 patients (26 neutron, 3 mixed beam, 2 photon) have experienced either sciatica beginning during or shortly after treatment, or diminished bladder or bowel continence that developed at a median time of 6.5 months following treatment. Sciatica responded to oral steroids and was usually self-limited, whereas sphincter dysfunction appears to be permanent. Pre-treatment risk factors for complications included a history of hypertension, diabetes, cigarette smoking or peripheral vascular disease, with 81% of affected patients having one or more risk factors compared witn 55% of unaffected patients (p = 0.01). Seven patients have moderate (5) or severe (2) residual problems, all in the cohorts receiving neutrons (6/7) or mixed beam therapy (1/7). (author). 31 refs.; 5 tabs.

  5. Rapid Estimation of Fast-Neutron Doses following Radiation Exposure in Criticality Accidents: The S{sup 32}(n, p)P{sup 32} Reaction in Body Hair; Prompte Evaluation des Doses de Neutrons Rapides apres une Exposition au Rayonnement a la Suite d'Accidents de Criticite: Reaction {sup 32}S(n, p){sup 32}P dans le Systeme Pileux; 0411 042b 0421 0414 ; Evaluacion Acelerada de Dosis de Neutrones Rapidos Despues de una Irradiacion Consecutiva a un Accidente de Criticidad: La Reaccion {sup 32}S(n, p){sup 32}P en el Pelo

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, D. F. [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1965-06-15

    Unique chemical composition, fixed anatomical location, and ready availability combine to make human hair a useful material for rapid estimation of fast neutron doses sustained by personnel involved in accidental nuclear critical excursions. The sulphur content of human hair is remarkably constant regardless of sex, colour, or distribution; values of 0.048 {+-}0.005 g sulphur per gram of hair indicate that 5% can be used as a standard figure for the abundance of sulphur in preliminary dose estimates without resorting to individual sulphur analyses. In the absence of easily removable external contamination, hair contains less than 0.025% phosphorus; since the activation cross-sections of phosphorus and sulphur are similar, the virtual absence of phosphorus permits the use of hair as a biological sulphur threshold detector for measuring the flux of neutrons with energies in excess of 2.5 MeV by the S{sup 32}(n, p)P{sup 32} reaction. Techniques for rapid isolation of radiochemically pure P{sup 32} have been developed with a view toward providing clinically useful estimates of the fast neutron exposure of criticality accident victims. In the absence of gross fission product contamination, preliminary estimates can be made within two hours; the more extensive procedure for eliminating fission products requires approximately six hours for a preliminary estimate. Experiments employing the well-defined fission spectrum of an unshielded critical assembly have consistently provided estimates of neutron dose within {+-}10% of referee dosimetry. Moreover, the fixed anatomical location of hair samples makes it possible to deduce orientation and asymmetry of exposure from a comparison of the relative specific activities of samples from different regioris of the body. Experience with three nuclear critical excursions resulting in fatalities has demonstrated that in each case exposures were markedly asymmetrical. Thus, P{sup 32} measurements on hair provide valuable complementary

  6. A neutron spectrometer for studying giant resonances with (p,n) reactions in inverse kinematics

    International Nuclear Information System (INIS)

    Stuhl, L.; Krasznahorkay, A.; Csatlós, M.; Algora, A.; Gulyás, J.; Kalinka, G.; Timár, J.; Kalantar-Nayestanaki, N.; Rigollet, C.; Bagchi, S.; Najafi, M.A.

    2014-01-01

    A neutron spectrometer, the European Low-Energy Neutron Spectrometer (ELENS), has been constructed to study exotic nuclei in inverse-kinematics experiments. The spectrometer, which consists of plastic scintillator bars, can be operated in the neutron energy range of 100 keV–10 MeV. The neutron energy is determined using the time-of-flight technique, while the position of the neutron detection is deduced from the time-difference information from photomultipliers attached to both ends of each bar. A novel wrapping method has been developed for the plastic scintillators. The array has a larger than 25% detection efficiency for neutrons of approximately 500 keV in kinetic energy and an angular resolution of less than 1°. Details of the design, construction and experimental tests of the spectrometer will be presented

  7. Multicenter, randomized comparison between magnetically navigated and manually guided radiofrequency ablation of atrioventricular nodal reentrant tachycardia (the MagMa-AVNRT-trial).

    Science.gov (United States)

    Reents, Tilko; Jilek, Clemens; Schuster, Peter; Nölker, Georg; Koch-Büttner, Katharina; Ammar-Busch, Sonia; Semmler, Verena; Bourier, Felix; Kottmaier, Marc; Kornmayer, Marie; Brooks, Stephanie; Fichtner, Stephanie; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele

    2017-12-01

    Remote magnetic navigation (RMN) is attributed to diminish radiation exposure for both patient and operator performing catheter ablation for different arrhythmia substrates. The purpose of this prospective, randomized study was to compare RMN with manually guided catheter ablation for AV nodal reentrant tachycardia (AVNRT) regarding fluoroscopy time/dosage, acute and long-term efficacy as well as safety. A total of 218 patients with AVNRT undergoing catheter ablation at three centers (male 34%, mean age 50 ± 17 years) were randomized to a manual approach (n = 113) or RMN (n = 105) using the Niobe ® magnetic navigation system. The primary study endpoint was total fluoroscopy time/dosage for patient and operator at the end of the procedure. Secondary endpoints included acute success, procedure duration, complications and success rate after 6 months. Fluoroscopy time and dosage for the patient were significantly reduced in the RMN group compared to the manual group (6 ± 6 vs. 11 ± 10 min; p < 0.001 and 425 ± 558 vs. 751 ± 900 cGycm 2 , p = 0.002). A reduction in fluoroscopy time/dose also applied to the operator (3 ± 5 vs. 7 ± 9 min 209 ± 444 vs. 482 ± 689 cGycm 2 , p < 0.001). Procedure duration was significantly longer in the RMN group (88 ± 29 vs. 79 ± 29 min; p = 0.03) and crossover from the RMN group to manual ablation occurred in 7.6% of patients (7.6 vs. 0.1%; p = 0.02). Acute success was achieved in 100% of patients in both groups. Midterm success after 6 months was 97 vs. 98% (p = 0.67). No complications occurred in both groups. The use of RMN for catheter ablation of AVNRT compared to a manual approach results in a reduction of fluoroscopy time and dosage of about 50% for both patients and physicians. Acute and midterm success and safety are comparable. RMN is a good alternative to a manual approach for AVNRT ablation.

  8. Development of silicone rubber-type neutron shielding material

    International Nuclear Information System (INIS)

    Do, Jae Bum; Cho, Soo Hang; Kim, Ik Soo; Oh, Seung Chul; Hong, Soon Seok; Noh, Sung Ki; Jeong, Duk Yeon.

    1997-06-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear/radiation facilities. On this study, we developed silicone rubber based neutron shielding materials and their various material properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. (author). 16 tabs., 17 figs., 25 refs

  9. Neutron detectors for the ESS diffractometers

    Czech Academy of Sciences Publication Activity Database

    Stefanescu, I.; Christensen, M.; Fenske, J.; Hall-Wilton, R.; Henry, P. F.; Kirstein, O.; Muller, M.; Nowak, G.; Pooley, D.; Raspino, D.; Rhodes, N.; Šaroun, Jan; Schefer, J.; Schooneveld, E.; Sykora, J.; Schweika, W.

    2017-01-01

    Roč. 12, JAN (2017), č. článku P01019. ISSN 1748-0221 R&D Projects: GA MŠk LM2015048 Institutional support: RVO:61389005 Keywords : instrumentation for neutron sources * neutron diffraction detectors * neutron detectors (cold, thermal, fast neutrons) Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.220, year: 2016

  10. Neutrons for Catalysis: A Workshop on Neutron Scattering Techniques for Studies in Catalysis

    International Nuclear Information System (INIS)

    Overbury, Steven H.; Coates, Leighton; Herwig, Kenneth W.; Kidder, Michelle

    2011-01-01

    This report summarizes the Workshop on Neutron Scattering Techniques for Studies in Catalysis, held at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on September 16 and 17, 2010. The goal of the Workshop was to bring experts in heterogeneous catalysis and biocatalysis together with neutron scattering experimenters to identify ways to attack new problems, especially Grand Challenge problems in catalysis, using neutron scattering. The Workshop locale was motivated by the neutron capabilities at ORNL, including the High Flux Isotope Reactor (HFIR) and the new and developing instrumentation at the SNS. Approximately 90 researchers met for 1 1/2 days with oral presentations and breakout sessions. Oral presentations were divided into five topical sessions aimed at a discussion of Grand Challenge problems in catalysis, dynamics studies, structure characterization, biocatalysis, and computational methods. Eleven internationally known invited experts spoke in these sessions. The Workshop was intended both to educate catalyst experts about the methods and possibilities of neutron methods and to educate the neutron community about the methods and scientific challenges in catalysis. Above all, it was intended to inspire new research ideas among the attendees. All attendees were asked to participate in one or more of three breakout sessions to share ideas and propose new experiments that could be performed using the ORNL neutron facilities. The Workshop was expected to lead to proposals for beam time at either the HFIR or the SNS; therefore, it was expected that each breakout session would identify a few experiments or proof-of-principle experiments and a leader who would pursue a proposal after the Workshop. Also, a refereed review article will be submitted to a prominent journal to present research and ideas illustrating the benefits and possibilities of neutron methods for catalysis research.

  11. Neutrons for Catalysis: A Workshop on Neutron Scattering Techniques for Studies in Catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Overbury, Steven {Steve} H [ORNL; Coates, Leighton [ORNL; Herwig, Kenneth W [ORNL; Kidder, Michelle [ORNL

    2011-10-01

    This report summarizes the Workshop on Neutron Scattering Techniques for Studies in Catalysis, held at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on September 16 and 17, 2010. The goal of the Workshop was to bring experts in heterogeneous catalysis and biocatalysis together with neutron scattering experimenters to identify ways to attack new problems, especially Grand Challenge problems in catalysis, using neutron scattering. The Workshop locale was motivated by the neutron capabilities at ORNL, including the High Flux Isotope Reactor (HFIR) and the new and developing instrumentation at the SNS. Approximately 90 researchers met for 1 1/2 days with oral presentations and breakout sessions. Oral presentations were divided into five topical sessions aimed at a discussion of Grand Challenge problems in catalysis, dynamics studies, structure characterization, biocatalysis, and computational methods. Eleven internationally known invited experts spoke in these sessions. The Workshop was intended both to educate catalyst experts about the methods and possibilities of neutron methods and to educate the neutron community about the methods and scientific challenges in catalysis. Above all, it was intended to inspire new research ideas among the attendees. All attendees were asked to participate in one or more of three breakout sessions to share ideas and propose new experiments that could be performed using the ORNL neutron facilities. The Workshop was expected to lead to proposals for beam time at either the HFIR or the SNS; therefore, it was expected that each breakout session would identify a few experiments or proof-of-principle experiments and a leader who would pursue a proposal after the Workshop. Also, a refereed review article will be submitted to a prominent journal to present research and ideas illustrating the benefits and possibilities of neutron methods for catalysis research.

  12. Effects of electro-acupuncture on ovarian P450arom, P450c17α and mRNA expression induced by letrozole in PCOS rats.

    Directory of Open Access Journals (Sweden)

    Jie Sun

    Full Text Available Hyperandrogenism is a core factor in the series of reproductive and endocrine metabolic disorders involved in polycystic ovary syndrome (PCOS. Abnormalities in enzymatic activity and the expression of ovarian granular cell layer P450arom and theca cell P450c17α can lead to an atypical environment of local ovarian hormones, including excessive androgen levels. Rat models prepared with letrozole exhibit similar endocrine and histological changes to those that occur in human PCOS. We used such a model to study the role of electro-acupuncture (EA in regulating ovarian P450arom and P450c17α enzymatic activity and mRNA expression in PCOS rats. Female Sprague Dawley (SD rats aged 42 days were randomly divided into 3 groups (control, PCOS, and PCOS EA consisting of 10 rats each. The PCOS and PCOS EA groups were administered a gavage of 1.0 mg/kg(-1 of letrozole solution once daily for 21 consecutive days. Beginning in the ninth week, the PCOS EA group was administered low-frequency EA treatment daily for 14 consecutive days. After the treatment, we obtained the following results. The estrous cycles were restored in 8 of the 10 rats in the PCOS EA group, and their ovarian morphologies and ultrastructures normalized. The peripheral blood measurements (with ELISA showed significantly decreased androgens (i.e., androstenedione and testosterone with significantly increased estrogens (i.e., estrone, estradiol and increased P450arom with decreased P450C17α. Immunohistochemistry and Western blotting methods showed enhanced expression of ovarian granular cell layer P450arom as well as decreased expression of theca cell layer P450C17α. Fluorescence quantitative PCR methods showed enhanced expression of ovarian granular cell layer P450arom mRNA as well as decreased expression of theca cell layer P450C17α mRNA. These results may help explain the effects of electro-acupuncture in changing the local ovarian hyperandrogenic environment and improving reproductive

  13. Effects of electro-acupuncture on ovarian P450arom, P450c17α and mRNA expression induced by letrozole in PCOS rats.

    Science.gov (United States)

    Sun, Jie; Jin, Chunlan; Wu, Huangan; Zhao, Jimeng; Cui, Yunhua; Liu, Huirong; Wu, Lingxiang; Shi, Yin; Zhu, Bing

    2013-01-01

    Hyperandrogenism is a core factor in the series of reproductive and endocrine metabolic disorders involved in polycystic ovary syndrome (PCOS). Abnormalities in enzymatic activity and the expression of ovarian granular cell layer P450arom and theca cell P450c17α can lead to an atypical environment of local ovarian hormones, including excessive androgen levels. Rat models prepared with letrozole exhibit similar endocrine and histological changes to those that occur in human PCOS. We used such a model to study the role of electro-acupuncture (EA) in regulating ovarian P450arom and P450c17α enzymatic activity and mRNA expression in PCOS rats. Female Sprague Dawley (SD) rats aged 42 days were randomly divided into 3 groups (control, PCOS, and PCOS EA) consisting of 10 rats each. The PCOS and PCOS EA groups were administered a gavage of 1.0 mg/kg(-1) of letrozole solution once daily for 21 consecutive days. Beginning in the ninth week, the PCOS EA group was administered low-frequency EA treatment daily for 14 consecutive days. After the treatment, we obtained the following results. The estrous cycles were restored in 8 of the 10 rats in the PCOS EA group, and their ovarian morphologies and ultrastructures normalized. The peripheral blood measurements (with ELISA) showed significantly decreased androgens (i.e., androstenedione and testosterone) with significantly increased estrogens (i.e., estrone, estradiol) and increased P450arom with decreased P450C17α. Immunohistochemistry and Western blotting methods showed enhanced expression of ovarian granular cell layer P450arom as well as decreased expression of theca cell layer P450C17α. Fluorescence quantitative PCR methods showed enhanced expression of ovarian granular cell layer P450arom mRNA as well as decreased expression of theca cell layer P450C17α mRNA. These results may help explain the effects of electro-acupuncture in changing the local ovarian hyperandrogenic environment and improving reproductive and

  14. Effects of Electro-Acupuncture on Ovarian P450arom, P450c17α and mRNA Expression Induced by Letrozole in PCOS Rats

    Science.gov (United States)

    Wu, Huangan; Zhao, Jimeng; Cui, Yunhua; Liu, Huirong; Wu, Lingxiang; Shi, Yin; Zhu, Bing

    2013-01-01

    Hyperandrogenism is a core factor in the series of reproductive and endocrine metabolic disorders involved in polycystic ovary syndrome (PCOS). Abnormalities in enzymatic activity and the expression of ovarian granular cell layer P450arom and theca cell P450c17α can lead to an atypical environment of local ovarian hormones, including excessive androgen levels. Rat models prepared with letrozole exhibit similar endocrine and histological changes to those that occur in human PCOS. We used such a model to study the role of electro-acupuncture (EA) in regulating ovarian P450arom and P450c17α enzymatic activity and mRNA expression in PCOS rats. Female Sprague Dawley (SD) rats aged 42 days were randomly divided into 3 groups (control, PCOS, and PCOS EA) consisting of 10 rats each. The PCOS and PCOS EA groups were administered a gavage of 1.0 mg/kg−1 of letrozole solution once daily for 21 consecutive days. Beginning in the ninth week, the PCOS EA group was administered low-frequency EA treatment daily for 14 consecutive days. After the treatment, we obtained the following results. The estrous cycles were restored in 8 of the 10 rats in the PCOS EA group, and their ovarian morphologies and ultrastructures normalized. The peripheral blood measurements (with ELISA) showed significantly decreased androgens (i.e., androstenedione and testosterone) with significantly increased estrogens (i.e., estrone, estradiol) and increased P450arom with decreased P450C17α. Immunohistochemistry and Western blotting methods showed enhanced expression of ovarian granular cell layer P450arom as well as decreased expression of theca cell layer P450C17α. Fluorescence quantitative PCR methods showed enhanced expression of ovarian granular cell layer P450arom mRNA as well as decreased expression of theca cell layer P450C17α mRNA. These results may help explain the effects of electro-acupuncture in changing the local ovarian hyperandrogenic environment and improving reproductive and

  15. Calculation of Spectra of Neutrons and Charged Particles Produced in a Target of a Neutron Generator

    Science.gov (United States)

    Gaganov, V. V.

    2017-12-01

    An algorithm for calculating the spectra of neutrons and associated charged particles produced in the target of a neutron generator is detailed. The products of four nuclear reactions 3H( d, n)4He, 2H( d, n)3He, 2H( d, p)3H, and 3He( d, p)4He are analyzed. The results of calculations are presented in the form of neutron spectra for several emission angles and spectra of associated charged particles emitted at an angle of 180° for a deuteron initial energy of 0.13 MeV.

  16. Atlas of neutron resonances

    CERN Document Server

    Mughabghab, Said

    2018-01-01

    Atlas of Neutron Resonances: Resonance Properties and Thermal Cross Sections Z= 1-60, Sixth Edition, contains an extensive list of detailed individual neutron resonance parameters for Z=1-60, as well as thermal cross sections, capture resonance integrals, average resonance parameters and a short survey of the physics of thermal and resonance neutrons. The long introduction contains: nuclear physics formulas aimed at neutron physicists; topics of special interest such as valence neutron capture, nuclear level density parameters, and s-, p-, and d-wave neutron strength functions; and various comparisons of measured quantities with the predictions of nuclear models, such as the optical model. As in the last edition, additional features have been added to appeal to a wider spectrum of users. These include: spin-dependent scattering lengths that are of interest to solid-state physicists, nuclear physicists and neutron evaluators; calculated and measured Maxwellian average 5-keV and 30-keV capture cross sections o...

  17. P-odd effects observed in the reactions with neutrons and isospin structure of weak nucleon-nucleon interaction

    International Nuclear Information System (INIS)

    Smotritskij, L.M.

    2001-01-01

    Application of resonance phase for two quasi-stationary states with similar spin and unlike parity is shown to enable to coordinate the experimentally observed signed dependence of P-odd effects in neutron reactions with the theory. The developed approach enables to obtain information on isospin structure of a weak nucleon-nucleon interaction [ru

  18. Energy dependence of the neutron multiplicity P/sub nu/ in fast neutron induced fission of /sup 235,238/U and 239Pu

    International Nuclear Information System (INIS)

    Zucker, M.S.; Holden, N.E.

    1986-01-01

    Certain applications require knowledge of the higher moments of the neutron multiplicity probability. It can be shown that the second factorial moment is proportional to the fission rate in the sample, and that the third factorial moment can be of use in disentangling spontaneous fission from induced fission. Using a source of unpublished work in which neutron multiplicities were derived for the fast neutron induced fission of U-235, U-238, and Pu-239, the multiplicity probability has been calculated as a function of neutron energy for the energy range 0 to 10 MeV

  19. Ibrutinib for patients with relapsed or refractory chronic lymphocytic leukaemia with 17p deletion (RESONATE-17): a phase 2, open-label, multicentre study.

    Science.gov (United States)

    O'Brien, Susan; Jones, Jeffrey A; Coutre, Steven E; Mato, Anthony R; Hillmen, Peter; Tam, Constantine; Österborg, Anders; Siddiqi, Tanya; Thirman, Michael J; Furman, Richard R; Ilhan, Osman; Keating, Michael J; Call, Timothy G; Brown, Jennifer R; Stevens-Brogan, Michelle; Li, Yunfeng; Clow, Fong; James, Danelle F; Chu, Alvina D; Hallek, Michael; Stilgenbauer, Stephan

    2016-10-01

    The TP53 gene, encoding tumour suppressor protein p53, is located on the short arm of chromosome 17 (17p). Patients with 17p deletion (del17p) chronic lymphocytic leukaemia have poor responses and survival after chemoimmunotherapy. We assessed the activity and safety of ibrutinib, an oral covalent inhibitor of Bruton's tyrosine kinase, in relapsed or refractory patients with del17p chronic lymphocytic leukaemia or small lymphocytic lymphoma. We did a multicentre, international, open-label, single-arm study at 40 sites in the USA, Canada, Europe, Australia, and New Zealand. Patients (age ≥18 years) with previously treated del17p chronic lymphocytic leukaemia or small lymphocytic lymphoma received oral ibrutinib 420 mg once daily until progressive disease or unacceptable toxicity. The primary endpoint was overall response in the all-treated population per International Workshop on Chronic Lymphocytic Leukaemia 2008 response criteria modified for treatment-related lymphocytosis. Preplanned exploratory analyses were progression-free survival, overall survival, sustained haematological improvement, and immunological improvement. Patient enrolment is complete, but follow-up is ongoing. Treatment discontinuation owing to adverse events, unacceptable toxicity, or death were collected as a single combined category. This study is registered with ClinicalTrials.gov, number NCT01744691. Between Jan 29, 2013, and June 19, 2013, 145 patients were enrolled. The all-treated population consisted of 144 patients with del17p chronic lymphocytic leukaemia or small lymphocytic lymphoma who received at least one dose of study drug, with a median age of 64 years (IQR 57-72) and a median of two previous treatments (IQR 1-3). At the prespecified primary analysis after a median follow-up of 11·5 months (IQR 11·1-13·8), 92 (64%, 95% CI 56-71) of 144 patients had an overall response according to independent review committee assessment; 119 patients (83%, 95% CI 76-88) had an overall

  20. Analysis of the neutron energy spectra from the sup(208)Pb (p,n) sup(208)Bi reaction at Esub(p)=200 MeV

    International Nuclear Information System (INIS)

    Ershov, S.N.; Fayans, S.A.; Gareev, F.A.; Pyatov, N.I.

    1986-01-01

    Microscopic calculation of the small-angle neutron energy spectra from the 208 Pb (p, n) 208 Bi reaction at Esub(p)=200 MeV are presented. It is shown that the distorted-wave impulse approximation and the microscopic theory of finite Fermi systems can be employed for describing the low-energy excitation region 0 <= Q <= 30 MeV with small momentum transfers. A quantitative estimate is obtained for the local charge of quasiparticles esub(q)[σtau]=0.8 that characterizes the quenching of the integral strength of spin-flip low-energy transitions and the relevant effects are discussed

  1. Calculations of accelerator-based neutron sources characteristics

    International Nuclear Information System (INIS)

    Tertytchnyi, R.G.; Shorin, V.S.

    2000-01-01

    Accelerator-based quasi-monoenergetic neutron sources (T(p,n), D(d;n), T(d;n) and Li (p,n)-reactions) are widely used in experiments on measuring the interaction cross-sections of fast neutrons with nuclei. The present work represents the code for calculation of the yields and spectra of neutrons generated in (p, n)- and ( d; n)-reactions on some targets of light nuclei (D, T; 7 Li). The peculiarities of the stopping processes of charged particles (with incident energy up to 15 MeV) in multilayer and multicomponent targets are taken into account. The code version is made in terms of the 'SOURCE,' a subroutine for the well-known MCNP code. Some calculation results for the most popular accelerator- based neutron sources are given. (authors)

  2. Personal fast neutrons dosimetry using radiophotoluminescent glass

    International Nuclear Information System (INIS)

    Salem, Y. O.; Nachab, A.; Nourreddine, A.; Roy, C.

    2013-06-01

    In a previous paper we described a new ambient RPL dosimeter that detects fast neutrons in a mixed n-γ field via (n, p) reactions in a polyethylene converter. In the present study, a personal dosimeter is introduced to enable evaluating the individual dose equivalent H p (10) taking into account the albedo. A calibration factor for estimating H p (10) has been determined from the diminishing angular response as the angle of neutron incidence increases to 60 deg from the normal. MCNPX simulations for 241 Am-Be and 252 Cf neutrons, together with a series of monoenergetic neutron beams from 0.144 to 5 MeV, have been used to characterize the dosimeter response, which agrees well with the experimental 241 Am-Be response. (authors)

  3. Effect of cobalt-60 {gamma} radiation and of thermal neutrons on high resistance P and N silicon. Possibility of obtaining a nuclear compensation for P type silicon; Effects du rayonnement {gamma} du cobalt 60 et de neutrons thermiques sur du silicium P et N de haute resistivite. Possibilite de realiser une compensation nucleaire d'un silicium du type P

    Energy Technology Data Exchange (ETDEWEB)

    Messier, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-11-01

    Type P silicon has been compensated by the production of a controlled and uniform amount of donor atoms ({sup 31}P) using thermal neutrons to bring about a nuclear transformation. It is shown that it is possible in this way to reduce by a factor of about one hundred the overall concentration of residual ionised impurities in the purest crystals obtained by floating zone purification (2 x 10{sup 12} atoms/cm{sup 3}). The degree compensation obtained is limited by the initial inhomogeneity of acceptor impurities which have to be compensated. Lattice defects which still remain after prolonged annealings reduce the life-time of the material to about 10 {mu}s approximately. Particle detectors having thicknesses of 2 to 5 mm have been built by this process; they give good results, particularly at low temperatures. A study has also been made of the number and of the nature of lattice defects produced by thermal neutrons in high resistivity P and N type crystals. These defects have been compared to those produced by {gamma} rays from {sup 60}Co. A discussion is given of the validity of the Wertheim model concerning pronounced recombination at low temperatures (77 deg. K - 300 deg. K) of primary defect-interstitial pairs. The nature of the defects introducing energy levels into the lower half of the forbidden band has been studied. (author) [French] On a compense du silicium de type P en produisant, au moyen de neutrons thermiques, par transmutation nucleaire une quantite controlee et uniforme d'atomes donneurs ({sup 31}P). On montre qu'on peut ainsi reduire de cent fois environ la densite nette d'impuretes ionisees residuelles subsistant dans les cristaux les plus purs obtenus par purification par zone flottante (2.10{sup 12} atomes/cm{sup 3}). Le degre de compensation obtenu est limite par i'inhomogeneite initiale des impuretes acceptrices a compenser. Des defauts de reseau qui subsistent meme apres des recuits prolonges reduisent la duree de vie du materiau a 10 {mu

  4. Mechanism of Cytochrome P450 17A1-Catalyzed Hydroxylase and Lyase Reactions

    DEFF Research Database (Denmark)

    Bonomo, Silvia; Jorgensen, Flemming Steen; Olsen, Lars

    2017-01-01

    Cytochrome P450 17A1 (CYP17A1) catalyzes C17 hydroxylation of pregnenolone and progesterone and the subsequent C17–C20 bond cleavage (lyase reaction) to form androgen precursors. Compound I (Cpd I) and peroxo anion (POA) are the heme-reactive species underlying the two reactions. We have characte...... the concept that the selectivity of the steroidogenic CYPs is ruled by direct interactions with the enzyme, in contrast to the selectivity of drug-metabolizing CYPs, where the reactivity of the substrates dominates....... characterized the reaction path for both the hydroxylase and lyase reactions using density functional theory (DFT) calculations and the enzyme–substrate interactions by molecular dynamics (MD) simulations. Activation barriers for positions subject to hydroxylase reaction have values close to each other and span...

  5. Electronic neutron sensor based on coincidence detection

    International Nuclear Information System (INIS)

    Barelaud, B.; Decossas, J.L.; Mokhtari, F.; Vareille, J.C.

    1996-01-01

    The last symposium on neutron dosimetry which took place in Paris in November 1995 have shown again that it doesn't exist any individual active neutron dosemeter. The state of art on electronic device, the needs of the nuclear power industry in individual neutron monitoring and the new trends of The last symposium on neutron dosimetry which took place in Paris in November 1995 have shown again that it doesn't exist any individual active neutron dosemeter. The state of art on electronic device, the needs of the nuclear power industry in individual neutron monitoring and the new trends of researches were presented. They confirm the relevance of our studies in progress in the C2M team of the University of Limoges. The aim of this work is to realize an individual electronic neutron dosemeter. The device in the progress of being development will operate either as a dosemeter or as ratemeter giving H p (10) and H p (10) either as a spectrometer permitting to characterize the primary neutron beam. (author)

  6. Studies of defects in neutron-irradiated p-type silicon by admittance measurements of n+-p diodes

    International Nuclear Information System (INIS)

    Tokuda, Y.; Usami, A.

    1978-01-01

    Defects introduced in p-type silicon by neutron irradiation were studied by measuring the admittance of n + -p diodes. It was shown that the energy levels and capture cross sections estimated from the temperature dependence of the admittance had some uncertainty due to the temperature dependence of the concentration of free carriers in the bulk and the high-frequency-junction capacitance. So, we presented the method of determination of the energy levels, capture cross sections, and concentrations of defects from the frequency dependence of the admittance. This method consists of the measurements of G/ω and C as a function of frequency. From this method, assuming that capture cross sections are independent of temperature, the energy levels of E/sub v/+0.16 and E/sub v/+0.36 eV were obtained. For these defects, the calculated values of the hole capture cross section were 2.4 x 10 -14 and 3.7 x 10 -14 cm 2 , respectively. Comparing with other published data, the energy level of E/sub v/+0.36 eV was found to be correlated with the divacancy

  7. Neutron radiography with the cyclotron

    International Nuclear Information System (INIS)

    Tazawa, Shuichi; Asada, Yorihisa; Yano, Munehiko; Nakanii, Takehiko.

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. This article presents a new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and is equipped with vertical and horizontal irradiation ports. The article describes a series of experiments, we conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained from 9 Be(p, n) reaction and thermalized by elastic scattering process. The article also describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Further, some of practical neutron radiograph examinations of aero-space components and museum art objects of classic bronze mirror and an attempt realizing real time imaging technique, are introduced in the article. (author)

  8. Instrumentation with polarized neutrons

    International Nuclear Information System (INIS)

    Boeni, P.; Muenzer, W.; Ostermann, A.

    2009-01-01

    Neutron scattering with polarization analysis is an indispensable tool for the investigation of novel materials exhibiting electronic, magnetic, and orbital degrees of freedom. In addition, polarized neutrons are necessary for neutron spin precession techniques that path the way to obtain extremely high resolution in space and time. Last but not least, polarized neutrons are being used for fundamental studies as well as very recently for neutron imaging. Many years ago, neutron beam lines were simply adapted for polarized beam applications by adding polarizing elements leading usually to unacceptable losses in neutron intensity. Recently, an increasing number of beam lines are designed such that an optimum use of polarized neutrons is facilitated. In addition, marked progress has been obtained in the technology of 3 He polarizers and the reflectivity of large-m supermirrors. Therefore, if properly designed, only factors of approximately 2-3 in neutron intensity are lost. It is shown that S-benders provide neutron beams with an almost wavelength independent polarization. Using twin cavities, polarized beams with a homogeneous phase space and P>0.99 can be produced without significantly sacrificing intensity. It is argued that elliptic guides, which are coated with large m polarizing supermirrors, provide the highest flux.

  9. Thermal neutron dose calculations in a brain phantom from 7Li(p,n) reaction based BNCT setup

    International Nuclear Information System (INIS)

    Elshahat, B.A.; Naqvi, A.A.; Maalej, N.; Abdallah, Khalid

    2006-01-01

    Monte Carlo simulations were carried out to calculate neutron dose in a brain phantom from a 7 Li(p,n) reaction based setup utilizing a high density polyethylene moderator with graphite reflector. The dimensions of the moderator and the reflector were optimized through optimization of epithermal /(fast +thermal) neutron intensity ratio as a function of geometric parameters of the setup. Results of our calculation showed the capability of our setup to treat the tumor within 4 cm of the head surface. The calculated Peak Therapeutic Ratio for the setup was found to be 2.15. With further improvement in the moderator design and brain phantom irradiation arrangement, the setup capabilities can be improved to reach further deep-seated tumor. (author)

  10. A neutron scattering study of the quasi-one-dimensional, dilute Ising-like antiferromagnet CsCo0.83Mg0.17Br3

    International Nuclear Information System (INIS)

    Rogge, R.B.; Gaulin, B.D.; Harrison, A.

    1992-01-01

    Neutron scattering measurements have been performed on a single crystal sample of CsCo 0.83 Mg 0.17 Br 3 , a quasi-one-dimensional, Ising-like antiferromagnet. Residual three-dimensional interactions between the dilute magnetic chains precipitate a phase transition to long range order at T N ∼ 8.5 K, and short range correlations persist as high as 40 K. Relatively high energy inelastic scattering from both ''bulk'' spin wave modes and ''end'' modes is observed from the finite chains. The low energy inelastic spectrum is dominated by soliton scattering due to anti-phase domain walls propagating along the finite chains

  11. Peace Corps Aquaculture Training Manual. Training Manual T0057.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This Peace Corps training manual was developed from two existing manuals to provide a comprehensive training program in fish production for Peace Corps volunteers. The manual encompasses the essential elements of the University of Oklahoma program that has been training volunteers in aquaculture for 25 years. The 22 chapters of the manual are…

  12. Neutron and gamma probes: Their use in agronomy. Second edition

    International Nuclear Information System (INIS)

    2003-01-01

    , water and nutrient management within cropping systems. In this context, neutron moisture probes in combination with isotope techniques are utilized to obtain precise and quantitative data on water and nutrient dynamics in the soil-plant system. The Centre for Nuclear Techniques in Agriculture (CENA) of the University of Sao Paulo, Piracicaba, Brazil is an institute established with IAEA support, with skilled and experienced staff and facilities to utilize nuclear techniques in agronomic and related environmental research. Many training events and formal undergraduate and post-graduate courses involving the use of neutron moisture meters have been offered by CENA. The concept of a training manual originated during a regional training workshop on the use of the neutron probe in water and nutrient balance studies, organized in 1997 in the frame of an IAEA Regional Technical Co-operation Project for Latin America entitled Plant Nutrition, Water and Soil Management (RLA/5/036-ARCAL XXII), for which the integrated approach was adopted. The original version (in Spanish) was a comprehensive manual covering theoretical and practical aspects required for the proper utilization of the equipment. It is hoped that this manual will be useful for future training events and serve as a key reference to soil/water scientists in the field of sustainable management of scarce water resources in both rain-fed and irrigated agricultural production systems

  13. Evaluation of new pharmaceuticals using in vivo neutron inelastic scattering and neutron activation analysis

    International Nuclear Information System (INIS)

    Kehayias, J.J.

    2000-01-01

    Nutritional status of patients can be evaluated by monitoring changes in body composition, including depletion of protein and muscle, adipose tissue distribution and changes in hydration status, bone or cell mass. Fast neutron activation (for N and P) and neutron inelastic scattering (for C and O) are used to assess in vivo elements characteristic of specific body compartments. The fast neutrons are produced with a sealed deuterium-tritium (D-T) neutron generator. This method provides the most direct assessment of body composition. Non-bone phosphorus for muscle is measured by the 31 P(n,α) 28 Al reaction, and nitrogen for protein via the (n,2n) fast neutron reaction. Inelastic neutron scattering is used for the measurement of total body carbon and oxygen. Carbon is used to derive body fat, after subtracting carbon contributions due to protein, bone and glycogen. Carbon-to-oxygen (C/O) ratio is used to measure distribution of fat and lean tissue in the body and to monitor small changes of lean mass and its quality. In addition to evaluating the efficacy of new treatments, the system is used to study the mechanisms of lean tissue depletion with aging and to investigate methods for preserving function and quality of life in the elderly. (author)

  14. Reactor neutron activation analysis for aluminium in the presence of phosphorus and silicon. Contributions of /sup 28/Al activities from /sup 31/P (n,. cap alpha. ) /sup 28/Al and /sup 28/Si (n,p) /sup 28/Al reactions

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, Yoshihiko (Kinki Univ., Higashi-Osaka, Osaka (Japan). Faculty of Science and Technology); Iwata, Shiro; Sasajima, Kazuhisa; Yoshimasu, Fumio; Yase, Yoshiro

    1984-01-01

    Reactor neutron activation analysis for aluminium in samples containing phosphorus and silicon was studied. The experiments were performed by using pneumatic tube of the Kyoto University Reactor (KUR). At first, the ratios of the /sup 28/Al activity produced from /sup 27/Al(n, ..gamma..) /sup 28/Al reaction by thermal neutrons to that from /sup 31/P(n, ..cap alpha..)/sup 28/Al reaction by fast neutrons, and to that from /sup 28/Si(n, p)/sup 28/Al reaction were measured by ..gamma..-ray spectrometry. With a ratio of about 5 for the thermal to fast neutron flux of KUR, the ratio of the /sup 28/Al activity from aluminium to that from phosphorus was to be 812 +- 7, and to that from silicon 282 +- 3. Secondly, the contributions of /sup 28/Al activities from phosphorus and silicon and the determination limit of aluminium were calculated for various parameters, such as fast neutron flux, thermal to fast neutron flux ratio, amounts of phosphorus and silicon, etc. Thirdly, on the basis of these results, aluminium contents in spinal cords and brains of amyotrophic lateral sclerosis, Parkinsonism-dementia complex and control cases were determined.

  15. Quasi-monoenergetic neutron energy spectra for 246 and 389 MeV (7)Li(p,n) reactions at angles from 0 degrees to 300 degrees

    CERN Document Server

    Iwamoto, Y; Nakamura, T; Nakashima, H; Mares, V; Itoga, T; Matsumoto, T; Nakane, Y; Feldbaumer, E; Jaegerhofer, L; Pioch, C; Tamii, A; Satoh, D; Masuda, A; Sato, T; Iwase, H; Yashima, H; Nishiyama, J; Hagiwara, M; Hatanaka, K; Sakamoto, Y

    2011-01-01

    The authors measured the neutron energy spectra of a quasi-monoenergetic (7)Li(p,n) neutron source with 246 and 389 MeV protons set at seven angles (0 degrees, 2.5 degrees, 5 degrees, 10 degrees, 15 degrees, 20 degrees and 30 degrees), using a time-of-flight (TOF) method employing organic scintillators NE213 at the Research Center for Nuclear Physics (RCNP) of Osaka University. The energy spectra of the source neutrons were precisely deduced down to 2 MeV at 0 degrees and 10 MeV at other angles. The cross-sections of the peak neutron production reaction at 0 degrees were on the 35-40 mb line of other experimental data, and the peak neutron angular distribution agreed well with the Taddeucci formula. Neutron energy spectra below 100 MeV at all angles were comparable, but the shapes of the continuum above 150 MeV changed considerably with the angle. In order to consider the correction required to derive the response in the peak region from the measured total response for high-energy neutron monitors such as DAR...

  16. Advanced neutron instrumentation at FRM-II

    International Nuclear Information System (INIS)

    Petry, Winfried

    2003-01-01

    The construction of the new German high flux neutron source FRM-II is finished and FRM-II is waiting for its licence to start nuclear operation. With the beginning of the routine operation 22 instruments will be in action, including 5 irradiation facilities and 17 beam tube instruments, most of them use neutron scattering techniques. Additional instruments are under construction. Some of these instruments are unique, others are expected to be the best of their kind, all instruments are based on innovative techniques. (author)

  17. Development of neutron calibration field using accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Mamoru [Tohoku Univ., Cyclotron and Radioisotope Center, Sendai, Miyagi (Japan)

    2003-03-01

    A brief summary is given on the fast neutron calibration fields for 1) 8 keV to 15 MeV range, and 2) 30-80 MeV range. The field for 8 keV to 15 MeV range was developed at the Fast Neutron Laboratory (FNL) at Tohoku University using a 4.5 MV pulsed Dynamitron accelerator and neutron production reactions, {sup 45}Sc(p, n), {sup 7}Li(p, n), {sup 3}H(p, n), D(d, n) and T(d, n). The latter 30-80 MeV fields are setup at TIARA of Takasaki Establishment of Japan Atomic Energy Research Institute, and at Cyclotron Radio Isotope Center (CYRIC) of Tohoku University using a 90 MeV AVF cyclotron and the {sup 7}Li(p, n) reaction. These fields have been applied for various calibration of neutron spectrometers and dosimeters, and for irradiation purposes. (author)

  18. Specific Destruction of HIV Proviral p17 Gene in T Lymphoid Cells Achieved by the Genome Editing Technology.

    Science.gov (United States)

    Kishida, Tsunao; Ejima, Akika; Mazda, Osam

    2016-01-01

    Recent development in genome editing technologies has enabled site-directed deprivation of a nucleotide sequence in the chromosome in mammalian cells. Human immunodeficiency (HIV) infection causes integration of proviral DNA into the chromosome, which potentially leads to re-emergence of the virus, but conventional treatment cannot delete the proviral DNA sequence from the cells infected with HIV. In the present study, the transcription activator-like effector nucleases (TALENs) specific for the HIV p17 gene were constructed, and their activities to destroy the target sequence were evaluated. SSA assay showed a high activity of a pair of p17-specific TALENs. A human T lymphoid cell line, Jurkat, was infected with a lentivirus vector followed by transfection with the TALEN-HIV by electroporation. The target sequence was destructed in approximately 10-95% of the p17 polymerase chain reaction clones, and the efficiencies depended on the Jurkat-HIV clones. Because p17 plays essential roles for assembly and budding of HIV, and this gene has relatively low nucleotide sequence diversity, genome editing procedures targeting p17 may provide a therapeutic benefit for HIV infection.

  19. Neutron scattering studies on protein dynamics using the human myelin peripheral membrane protein P2

    Directory of Open Access Journals (Sweden)

    Laulumaa Saara

    2015-01-01

    Full Text Available Myelin is a multilayered proteolipid membrane structure surrounding selected axons in the vertebrate nervous system, which allows the rapid saltatory conduction of nerve impulses. Deficits in myelin formation and maintenance may lead to chronic neurological disease. P2 is an abundant myelin protein from peripheral nerves, binding between two apposing lipid bilayers. We studied the dynamics of the human myelin protein P2 and its mutated P38G variant in hydrated powders using elastic incoherent neutron scattering. The local harmonic vibrations at low temperatures were very similar for both samples, but the mutant protein had increased flexibility and softness close to physiological temperatures. The results indicate that a drastic mutation of proline to glycine at a functional site can affect protein dynamics, and in the case of P2, they may explain functional differences between the two proteins.

  20. Neutron scattering studies on protein dynamics using the human myelin peripheral membrane protein P2

    Science.gov (United States)

    Laulumaa, Saara; Kursula, Petri; Natali, Francesca

    2015-01-01

    Myelin is a multilayered proteolipid membrane structure surrounding selected axons in the vertebrate nervous system, which allows the rapid saltatory conduction of nerve impulses. Deficits in myelin formation and maintenance may lead to chronic neurological disease. P2 is an abundant myelin protein from peripheral nerves, binding between two apposing lipid bilayers. We studied the dynamics of the human myelin protein P2 and its mutated P38G variant in hydrated powders using elastic incoherent neutron scattering. The local harmonic vibrations at low temperatures were very similar for both samples, but the mutant protein had increased flexibility and softness close to physiological temperatures. The results indicate that a drastic mutation of proline to glycine at a functional site can affect protein dynamics, and in the case of P2, they may explain functional differences between the two proteins.

  1. Neutron-Star Merger Detected By Many Eyes and Ears

    Science.gov (United States)

    Kohler, Susanna

    2017-10-01

    of gamma-ray bursts, that some of the heaviest elements in the universe are produced during the collision of these stars, and that jets of high-energy particles are created that subsequently interact with their environment.As with any interesting scientific discovery, new points of exploration have arisen we can now wonder why the gamma-ray burst was unusually weak given its close distance, for instance, or why we didnt detect any neutrinos from the outflow.In spite of our new questions, the combination of these recent discoveries provide a resounding verification of our understanding of how compact objects merge. The various signals that began on 17 August, 2017 have simultaneously confirmed a stack of carefully constructed theories that were crafted over decades to explain how seemingly unrelated electromagnetic signals might all tie together. Its a beautiful thing when science works out this well!For more information, check out the ApJL Focus Issue on this result here:Focus on The Electromagnetic Counterpart of the Neutron Star Binary Merger GW170817 CitationAbbott, B.P. et al 2017 ApJL 848 L12. doi:10.3847/2041-8213/aa91c9

  2. MULTI - A multigroup or multipoint P{sub 3} programme for calculating thermal neutron spectra in a reactor cell

    Energy Technology Data Exchange (ETDEWEB)

    Matausek, M V [Boris Kidric Institute of Nuclear Sciences Vinca, Beograd (Yugoslavia)

    1968-06-15

    Programme MULTI calculates the space energy distribution of thermal neutrons in a multizone, cylindrical, infinitely long reactor lattice by using the multigroup or multipoint P{sub 3} approximation. This report presents a short description of the algorithm and the programme and gives the instructions for its exploitation. (author)

  3. PFPF canister counter for foreign plutonium (PCAS-3) hardware operations and procedures manual

    International Nuclear Information System (INIS)

    Menlove, H.O.; Baca, J.; Kroncke, K.E.; Miller, M.C.; Takahashi, S.; Seki, S.; Inose, S.; Yamamoto, T.

    1993-01-01

    A neutron coincidence counter has been designed for the measurement of plutonium powder contained in tall storage canisters. The counter was designed for installation in the Plutonium Fuel Production Facility fabrication plant. Each canister contains from one to five cans of PuO 2 . The neutron counter measures the spontaneous-fission rate from the plutonium and, when this is combined with the plutonium isotopic ratios, the plutonium mass is determined. The system can accommodate plutonium loadings up to 12 kg, with 10 kg being a typical loading. Software has been developed to permit the continuous operation of the system in an unattended mode. Authentication techniques have been developed for the system. This manual describes the system and its operation and gives performance and calibration parameters for typical applications

  4. MOTORIC SPEED AND MANUAL DEXTERITY OF CHILDERN WITH IMPAIRED VISION

    Directory of Open Access Journals (Sweden)

    Dženana Radžo Alibegović

    2017-04-01

    Full Text Available The aim of this study was to estimate the motoric speed and manual dexterity of children with visual impairments. The research is covered by a sample size of 35 participants with visual impairment, with ages between 7 and 15 years, of which 19 participants with visual impairment were male and 16 participants with impaired vision were female. The study was conducted in 17 primary schools in the municipality of Tuzla, Bosnia and Herzegovina. The results showed that the motoric speed and manual dexterity of children with visual impairment is evenly developed on the right and left hand, and also on both hands together and that there is a relationship between the motoric speed and manual dexterity of the right and left hand and both hands together.

  5. Neutron absorbed dose in a pacemaker CMOS

    International Nuclear Information System (INIS)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R.; Paredes G, L.

    2012-01-01

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10 -17 Gy per neutron emitted by the source. (Author)

  6. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: fermineutron@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-06-15

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10{sup -17} Gy per neutron emitted by the source. (Author)

  7. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  8. EXTINCTION IN THE COMA OF COMET 17P/HOLMES

    International Nuclear Information System (INIS)

    Lacerda, Pedro; Jewitt, David

    2012-01-01

    On 2007 October 29, the outbursting comet 17P/Holmes passed within 0.''79 of a background star. We recorded the event using optical, narrowband photometry and detect a 3%-4% dip in stellar brightness bracketing the time of closest approach to the comet nucleus. The detected dimming implies an optical depth τ ≈ 0.04 at 1.''5 from the nucleus and an optical depth toward the nucleus center τ n d = 0.006 ± 0.002 at α = 16° phase angle. Our measurements place the most stringent constraints on the extinction optical depth of any cometary coma.

  9. EXTINCTION IN THE COMA OF COMET 17P/HOLMES

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Pedro [Astrophysics Research Centre, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Jewitt, David, E-mail: lacerda.pedro@gmail.com [Department of Earth and Space Sciences, University of California Los Angeles (UCLA), 595 Charles Young Drive, Los Angeles, CA 90095-1567 (United States)

    2012-11-20

    On 2007 October 29, the outbursting comet 17P/Holmes passed within 0.''79 of a background star. We recorded the event using optical, narrowband photometry and detect a 3%-4% dip in stellar brightness bracketing the time of closest approach to the comet nucleus. The detected dimming implies an optical depth {tau} Almost-Equal-To 0.04 at 1.''5 from the nucleus and an optical depth toward the nucleus center {tau}{sub n} < 13.3. At the time of our observations, the coma was optically thick only within {rho} {approx}< 0.''01 from the nucleus. By combining the measured extinction and the scattered light from the coma, we estimate a dust red albedo p{sub d} = 0.006 {+-} 0.002 at {alpha} = 16 Degree-Sign phase angle. Our measurements place the most stringent constraints on the extinction optical depth of any cometary coma.

  10. CT-based manual segmentation and evaluation of paranasal sinuses.

    Science.gov (United States)

    Pirner, S; Tingelhoff, K; Wagner, I; Westphal, R; Rilk, M; Wahl, F M; Bootz, F; Eichhorn, Klaus W G

    2009-04-01

    Manual segmentation of computed tomography (CT) datasets was performed for robot-assisted endoscope movement during functional endoscopic sinus surgery (FESS). Segmented 3D models are needed for the robots' workspace definition. A total of 50 preselected CT datasets were each segmented in 150-200 coronal slices with 24 landmarks being set. Three different colors for segmentation represent diverse risk areas. Extension and volumetric measurements were performed. Three-dimensional reconstruction was generated after segmentation. Manual segmentation took 8-10 h for each CT dataset. The mean volumes were: right maxillary sinus 17.4 cm(3), left side 17.9 cm(3), right frontal sinus 4.2 cm(3), left side 4.0 cm(3), total frontal sinuses 7.9 cm(3), sphenoid sinus right side 5.3 cm(3), left side 5.5 cm(3), total sphenoid sinus volume 11.2 cm(3). Our manually segmented 3D-models present the patient's individual anatomy with a special focus on structures in danger according to the diverse colored risk areas. For safe robot assistance, the high-accuracy models represent an average of the population for anatomical variations, extension and volumetric measurements. They can be used as a database for automatic model-based segmentation. None of the segmentation methods so far described provide risk segmentation. The robot's maximum distance to the segmented border can be adjusted according to the differently colored areas.

  11. Experiments on iron shield transmission of quasi-monoenergetic neutrons generated by 43- and 68-MeV protons via the 7Li(p,n) reaction

    International Nuclear Information System (INIS)

    Nakashima, Hiroshi; Tanaka, Shun-ichi; Nakao, Noriaki

    1996-03-01

    In order to provide benchmark data of neutrons transmitted through iron shields in the intermediate-energy region, spatial distributions of neutron energy spectra and reaction rates behind and inside the iron shields of thickness up to 130 cm were measured for 43- and 68-MeVp- 7 Li neutrons using a quasi-monoenergetic neutron beam source at the 90-MV AVF cyclotron facility of the TLARA facility in JAERI. The measured data by five kinds of detectors: the BC501A detector, the Bonner ball counter, 238 U and 232 Th fission counters, 7 LiF and nat LiF TLDs and solid state nuclear track detector, are numerically provided in this report in the energy region between 10 -4 eV and the energy of peak neutrons generated by the 7 Li(p,n) reaction. (author)

  12. Fast and epithermal neutron radiography using neutron irradiator

    International Nuclear Information System (INIS)

    Oliveira, Karol A.M. de; Crispim, Verginia R.; Ferreira, Francisco J.O.

    2013-01-01

    The neutron radiography technique (NR) with neutrons in the energy range fast to epithermal is a powerful tool used in no-destructive inspection of bulky objects of diverse materials, including those rich in hydrogen, oxygen, nitrogen ad carbon. Thus, it can be used to identify, inclusions, voids and thickness differences in materials such as explosive artifacts and narcotics. Aiming at using NR with fast and epithermal neutrons, an Irradiator was constructed by: a 241 Am-Be source, with 5 Ci activity, a collimator with adjustable collimation rate, L/D; and a shield device composed by plates of borated paraffin and iron. The test specimens chosen were a Beam Purity Indicator (BPI) and an Indicator of Visual Resolution (IVR). The neutron radiography images obtained had a resolution of 444.4 μm and 363.6 μm respectively when registered in: 1) the sheet of the nuclear track solid detector, CR-39 type, through X (n,p) Y nuclear reaction; and 2) Kodak Industrex M radiographic film plate in close contact with a boron converter screen, both stored in a Kodak radiographic cassette. (author)

  13. Neutronic study of the two french heavy water reactors

    International Nuclear Information System (INIS)

    Horowitz, J.

    1955-01-01

    The two french reactors - the reactor of Chatillon, named Zoe, and the reactor of Saclay - P2 - were the object of detailed neutronic studies which the main ideas are exposed in this report. These studies were mostly done by the Department of the Reactor Studies (D.E.P.). We have thus studied the distribution of neutronic fluxes; the factors influencing reactivity; the link between reactivity and divergence with the formula of Nordheim; the mean time life of neutrons; neutron spectra s of P2; the xenon effect; or the effect of the different adjustments of the plates and controls bar. (M.B.) [fr

  14. Black and grey neutron detectors

    International Nuclear Information System (INIS)

    Gabbard, F.

    1977-01-01

    Recent progress in the development and use of ''black'' and ''grey'' detectors is reviewed. Such detectors are widely used for counting neutrons in (p,n) and (α,n) experiments and in neutron cross section measurements. Accuracy of each detector is stressed. 19 figures

  15. The Trojan Horse Method as a tool to investigate low-energy resonances: the 18O(p, α)15N and 17O(p, α)14N cases

    International Nuclear Information System (INIS)

    La Cognata, M.; Sergi, M. L.; Spitaleri, C.; Cherubini, S.; Gulino, M.; Kiss, G.; Lamia, L.; Pizzone, R. G.; Romano, S.; Mukhamedzhanov, A.; Goldberg, V.; Tribble, R.; Coc, A.; Hammache, F.; Sereville, N. de; Irgaziev, B.; Tumino, A.

    2010-01-01

    The 18 O(p, α) 15 N and 17 O(p, α) 14 N reactions are of primary importance in several as-trophysical scenarios, including nucleosynthesis inside Asymptotic Giant Branch stars and oxygen and nitrogen isotopic ratios in meteorite grains. They are also key reactions to understand exotic systems such as R-Coronae Borealis stars and novae. Thus, the measurement of their cross sections in the low energy region can be crucial to reduce the nuclear uncertainty on theoretical predictions, because the resonance parameters are poorly determined. The Trojan Horse Method, in its newly developed form particularly suited to investigate low-energy resonances, has been applied to the 2 H( 18 O, α 15 N)n and 2 H( 17 O, α 14 N)n reactions to deduce the 18 O(p, α) 15 N and 17 O(p, α) 14 N cross sections at low energies. Resonances in the 18 O(p, α) 15 N and 17 O(p, α) 14 N excitation functions have been studied and the resonance parameters deduced.

  16. Device fabrication, characterization, and thermal neutron detection response of LiZnP and LiZnAs semiconductor devices

    Science.gov (United States)

    Montag, Benjamin W.; Ugorowski, Philip B.; Nelson, Kyle A.; Edwards, Nathaniel S.; McGregor, Douglas S.

    2016-11-01

    Nowotny-Juza compounds continue to be explored as candidates for solid-state neutron detectors. Such a device would have greater efficiency, in a compact form, than present day gas-filled 3He and 10BF3 detectors. The 6Li(n,t)4He reaction yields a total Q-value of 4.78 MeV, larger than 10B, an energy easily identified above background radiations. Hence, devices fabricated from semiconductor compounds having either natural Li (nominally 7.5% 6Li) or enriched 6Li (usually 95% 6Li) as constituent atoms may provide a material for compact high efficiency neutron detectors. Starting material was synthesized by preparing equimolar portions of Li, Zn, and As sealed under vacuum (10-6 Torr) in quartz ampoules lined with boron nitride and subsequently reacted in a compounding furnace [1]. The raw synthesized material indicated the presence high impurity levels (material and electrical property characterizations). A static vacuum sublimation in quartz was performed to help purify the synthesized material [2,3]. Bulk crystalline samples were grown from the purified material [4,5]. Samples were cut using a diamond wire saw, and processed into devices. Bulk resistivity was determined from I-V curve measurements, ranging from 106-1011 Ω cm. Devices were characterized for sensitivity to 5.48 MeV alpha particles, 337 nm laser light, and neutron sensitivity in a thermal neutron diffracted beam at the Kansas State University TRIGA Mark II nuclear reactor. Thermal neutron reaction product charge induction was measured with a LiZnP device, and the reaction product spectral response was observed.

  17. Beta-delayed neutron decay of $^{33}$Na

    CERN Document Server

    Radivojevic, Z; Caurier, E; Cederkäll, J; Courtin, S; Dessagne, P; Jokinen, A; Knipper, A; Le Scornet, G; Lyapin, V G; Miehé, C; Nowacki, F; Nummela, S; Oinonen, M; Poirier, E; Ramdhane, M; Trzaska, W H; Walter, G; Äystö, J

    2002-01-01

    Beta-delayed neutron decay of /sup 33/Na has been studied using the on-line mass separator ISOLDE. The delayed neutron spectra were measured by time-of-flight technique using fast scintillators. Two main neutron groups at 800(60) and 1020(80) keV were assigned to the /sup 33/Na decay, showing evidence for strong feeding of states at about 4 MeV in /sup 33/Mg. By simultaneous beta - gamma -n counting the delayed neutron emission probabilities P/sub 1n/ = 47(6)% and P /sub 2n/ = 13(3)% were determined. The half-life value for /sup 33 /Na, T/sub 1/2/ = 8.0(3) ms, was measured by three different techniques, one employing identifying gamma transitions and two employing beta and neutron counting. (21 refs).

  18. Performance Test of BF3 Neutron Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yu Sun; Shin, Ho Cheol [KHNP-CRI, Daejeon (Korea, Republic of); Cho, Jin Bok; Oh, Sae Hyun; Ryou, Seok Jean [USERS, Daejeon (Korea, Republic of)

    2015-10-15

    The neutron detecting system of First-of-a-kind plant such an APR1400 at Shin Kori should have been verified in the condition of low operating temperature and pressure of the primary coolant system before receiving the operation license. Auxiliary Ex-core Neutron Flux Monitoring System (AENFMS) is supposed to be installed using BF3 neutron detector in Shin Kori plant. The performance test of AENFMS was conducted to measure neutron sensitivity, moderation ratio and count rate in the same condition with Ex-core Neutron Flux Monitoring System (ENFMS) of APR1400 to verify its detection characteristics in compliance with the functional requirement. Performance test has been conducted for AENFMS of APR1400 to verify BF3 neutron sensitivity, moderation ration of PE, expecting neutron signal count rate from AENFMS, possible extending cable length from detector to pre-amplifier. As a result of measurement, the neutron sensitivity of 34.246±0.168(95%CI)cps/nv, moderation ratio of 11.343±0.039(95%CI) and AENFMS expecting count rate related to ENFMS of 17.8 times are acceptable in compliance with functional requirement, respectively.

  19. PNG-300 a nanosecond pulsed neutron generator

    International Nuclear Information System (INIS)

    Sztaricskai, T.; Vasvary, L.; Petoe, G.C.; Devkin, B.V.

    1985-01-01

    The design and operation of a nanosecond-pulse neutron generator is reported. It was constructed for the measurement of prompt neutron and gamma radiation in experimental studies of fast neutron reactions by time of flight techniques. The acceleration voltage is 300 kV and the total resolution of the generator-neutron spectrometer system is 2 ns. The ion-optical system, the vacuum system and the control of the neutron generator is described in detail. The equipment was used for prompt neutron and gamma radiation induced in construction materials. (R.P.)

  20. International key comparison of neutron fluence measurements in mono-energetic neutron fields: C.C.R.I.(3)-K10

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.; Wang, Z.; Rong, C. [China Institute of Atomic Energy (CIAE), Beijing, People' s Republic of China (China); Lovestam, G.; Plompen, A.; Puglisi, N. [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Geel (Belgium); Gilliam, D.M.; Eisenhauer, C.M.; Nico, J.S.; Dewey, M.S. [National Institute of Standards and Technology (NIST), Gaithersburg (United States); Kudo, K.; Uritani, A.; Harano, H.; Takeda, N. [National Metrology Institute of Japan (NMIJ), Tsukuba (Japan); Thomas, D.J.; Roberts, N.J.; Bennett, A.; Kolkowski, P. [National Physical Laboratory (NPL), Teddington (United Kingdom); Moisseev, N.N.; Kharitonov, I.A. [Mendeleyev Institute for Metrology (VNIIM), St Petersburg (Russian Federation); Guldbakke, S.; Klein, H.; Nolte, R.; Schlegel, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany)

    2007-12-15

    C.C.R.I. Section III (neutron measurements) conducted a unique key comparison of neutron fluence measurements in mono-energetic neutron fields. In contrast to former comparisons, here the fluence measurements were performed with the participants' instruments in the same neutron fields at the P.T.B. accelerator facility. Seven laboratories- the C.I.A.E. (China), I.R.M.M. (E.C.), N.M.I.J. (Japan), N.I.S.T. (USA), N.P.L. (UK), P.T.B. (Germany) and the V.N.I.I.M. (Russia)-employed their primary standard reference methods or transfer instruments carefully calibrated against their primary standards, to determine the fluence of 0.144 MeV, 1.2 MeV, 5.0 MeV and 14.8 MeV neutrons and reported calibration coefficients for a selected neutron monitor and each neutron energy with a detailed uncertainty budget for the measurements. The key comparison reference values (K.C.R.V.) were finally evaluated as the weighted mean values of the neutron fluence at 1 m distance from the target in vacuum per neutron monitor count. The uncertainties of each K.C.R.V. amounted to about 1%. The degree of equivalence (D.o.E.), defined as the deviation of the result reported by the laboratories for each energy from the corresponding K.C.R.V., and the associated expanded uncertainty are also reported. The deviations between the results of two laboratories each with the corresponding expanded uncertainties complete the documentation of the degrees of equivalence. (authors)

  1. Development of epoxy resin-type neutron shielding materials (I)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo Haeng; Kim, Ik Soo; Shin, Young Joon; Do, Jae Bum; Ro, Seung Gy

    1997-12-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear /radiation facilities. On this study, we developed epoxy resin based neutron shielding materials and their various materials properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. (author). 31 refs., 22 tabs., 17 figs.

  2. Thermal and magnetic properties of neutron matter

    International Nuclear Information System (INIS)

    Abd-Alla, M.; Ragab, H.S.; Hassan, M.Y.M.

    1990-01-01

    The Thomas-Fermi model is used to calculate the equation of state of thermal polarized neutron matter applying Seyler-Blanchard interaction. The resulting equation of state is stiff and has a small dependence on both the temperature and the spin excess parameter. We expand the Fermi integrals in powers of temperature up to second order to examine the T 2 approximation for neutron matter. It is found to be reliable up to T = 10 MeV. We also studied the ferromagnetic transition in neutron matter. We found a ferromagnetic transition at density ρ ≅ 2ρ0. This ferromagnetic transition is found to have a small dependence on both the temperature and the spin excess parameter. We also studied the dependence of the effective mass and the sound velocity for polarized neutron matter on temperature. (author). 36 refs, 17 figs

  3. The A-B and A-C experiments with neutrons

    International Nuclear Information System (INIS)

    Klein, A.G.

    1991-01-01

    The Aharonov-Bohm (A -B) and Aharonov-Casher (A - C) effects have, in recent years, been subjected to experimental verification using electron as well as neutron interferometry. This paper summarises these effects, concentrating on the neutron experiments, and discusses future possibilities. The refinments of the single crystal interferometer had allowed first-order sensitivity to the A - C phase shift to be achieved. Within experimental uncertainty, no measurable magnetic (or vector) A - B effect has been found for neutrons. A scalar A -B experiment with neutrons is now underway at the Missouri Research Reactor, as a collaboration between the University of Melbourne and the University of Missoury. It uses neutrons for exploring the phase shift caused by a scalar potential. A brief description of the actual experiment is given. 17 refs., 3 figs

  4. ISINN-2. Neutron spectroscopy, nuclear structure and related topics

    International Nuclear Information System (INIS)

    1994-01-01

    The proceedings contain the materials presented at the Second International Seminar on Neutron-Nucleus Interactions (ISINN-2) dealing with the problems of neutron spectroscopy, nuclear structure and related topics. The Seminar took place in Dubna on April 26-28, 1994. Over 120 scientists from Belgium, Bulgaria, Czech Republic, Germany, Holland, Italy, Japan, Latvia, Mexico, Poland, Slovakia, Slovenia, Ukraine, US and about 10 Russian research institutes took part in the Seminar. The main problems discussed are the following: P-odd and P-even angular correlation and T-reversal invariance in neutron reactions, nuclear structure investigations by neutron capture, the mechanism of neutron reactions, nuclear fission processes, as well as neutron data for nuclear astrophysics

  5. Calculations of neutron spectra after neutron-neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, B E [Gettysburg College, Box 405, Gettysburg, PA 17325 (United States); Stephenson, S L [Gettysburg College, Box 405, Gettysburg, PA 17325 (United States); Howell, C R [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Mitchell, G E [North Carolina State University, Raleigh, NC 27695-8202 (United States); Tornow, W [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Furman, W I [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Lychagin, E V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Muzichka, A Yu [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Nekhaev, G V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Strelkov, A V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Sharapov, E I [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Shvetsov, V N [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation)

    2004-09-01

    A direct neutron-neutron scattering length, a{sub nn}, measurement with the goal of 3% accuracy (0.5 fm) is under preparation at the aperiodic pulsed reactor YAGUAR. A direct measurement of a{sub nn} will not only help resolve conflicting results of a{sub nn} by indirect means, but also in comparison to the proton-proton scattering length, a{sub pp}, shed light on the charge-symmetry of the nuclear force. We discuss in detail the analysis of the nn-scattering data in terms of a simple analytical expression. We also discuss calibration measurements using the time-of-flight spectra of neutrons scattered on He and Ar gases and the neutron activation technique. In particular, we calculate the neutron velocity and time-of-flight spectra after scattering neutrons on neutrons and after scattering neutrons on He and Ar atoms for the proposed experimental geometry, using a realistic neutron flux spectrum-Maxwellian plus epithermal tail. The shape of the neutron spectrum after scattering is appreciably different from the initial spectrum, due to collisions between thermal-thermal and thermal-epithermal neutrons. At the same time, the integral over the Maxwellian part of the realistic scattering spectrum differs by only about 6 per cent from that of a pure Maxwellian nn-scattering spectrum.

  6. Scattering of Neutrons by Liquid Bromine; Diffusion des neutrons par le brome liquide; R; Dispersion de neutrones por bromo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Coote, G E; Haywood, B C [Atomic Energy of Canada Ltd., Chalk River, Ontario (Canada)

    1963-01-15

    Neutrons of 0.037 eV and 0.0088 eV were scattered from a thin sample of liquid bromine at room temperature, and the energy distributions of the scattered neutrons measured at angles from 10{sup o} to 160{sup o} by the time-of-flight method. The angular distribution confirms the results of a previous study by Caglioti. Spectra were expressed in the form of the ''scattering law'' S({alpha},{beta}) of Egelstaff and analysed to derive the generalized frequency distribution p({beta}) of atomic motions in the liquid. The function p({beta}) has a broad smooth peak centred at {beta}{approx}0.3, and shows no evidence for discrete levels in the measured range 0<{beta}< 0.8: the general shape of the curve supports the 'quasi-crystalline' picture of the liquid. Difficulty in the absolute normalization of p({beta}) is discussed. (author) [French] Des neutrons de 0,037 eV et 0,0088 eV ont ete dissuses par un echantillon mince de brome liquide a la temperature ambiante; on a mesure, par la methode du temps de vol, les distributions d'energies des neutrons diffuses, pour des angles compris entre 10{sup o} et 160{sup o}. La distribution angulaire confirme les resultats d'une etude anterieure faite par Caglioti. Les spectres ont ete exprimes d'apres la ''loi de dispersion'' S({alpha},{beta}) d'Egelstaff et analyses pour determiner la distribution generalisee des frequences p({beta}) des mouvements atomiques dans le liquide. La fonction p({beta}) comporte un pic large et a faible pente dont le centre est a {beta} {approx} 0,3 et ne presente aucune indication de niveaux discrets dans la gamme mesuree 0 < {beta} < 0,8; la forme generale de la courbe confirme l'image ''quasi cristalline'' du liquide. Les auteurs examinent les difficultes qui s'opposent a la normalisation absolue de p({beta}). (author) [Spanish] Los autores han estudiado la dispersion de neutrones de 0,037 eV y 0,0088 eV en una muestra de bromo liquido de espesor reducido, a temperatura ambiente. La distribucion

  7. Cross sections for the reactions 54Fe(n,α)51Cr, 54Fe(n,p)54Mn, and 56Fe(n,p)56Mn

    International Nuclear Information System (INIS)

    Paulsen, A.; Widera, R.; Arnotte, F.; Liskien, H.

    1979-01-01

    Ratios of cross sections for the reactions 54 Fe(n,α) 51 Cr, 54 Fe(n,p) 54 Mn, and 56 Fe(n,p) 56 Mn were measured by the activation technique. In the 6- to 10-MeV energy range, quasi-monoenergetic neutrons produced by the D(d,n) source reaction were used, while additional data were obtained between 12 and 17 MeV by use of the T(d,n) source reaction. The cross-section ratios have accuracies between 1.5 and 4.5%. 1 figure, 3 tables

  8. Tl response of LiF:Mg, Cu, P + PTFE to Am-Be neutrons

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2000-01-01

    In different laboratories of the world it is followed the research about development of new Tl materials, whose main characteristics should be their equivalence with the tissue and their high sensibility to any type of radiation. The study consists in to measure the Tl peak intensity which TLD-100 presents at being irradiated with neutrons and that appears over 250 Centigrade, for compare it with the Tl intensity of the LiF: Mg, Cu, P + PTFE dosemeters. However, not all dosemeters of the same group show the interesting peak, by this only can be the total Tl intensity of dosemeters studied. In the ININ dosemeters development laboratory, we have developed a Tl material of lithium fluoride activated with magnesium, copper and phosphorus (LiF: Mg, Cu, P) that in polycrystalline powder form is almost 35 times more sensitive than the TLD-100 commercial dosemeter of Harshaw/Filtrol, USA. With the use of polytetrafluorethylene (PTFE) and with the above described Tl material, it has been possible to obtain dosemeters in pellet form of LiF: Mg, Cu, P + PTFE. (Author)

  9. Neutron wave reflexions in interface media with transport equation P1 approximation

    International Nuclear Information System (INIS)

    Oliveira Vellozo, S. de.

    1977-01-01

    The propagation of neutron waves in non multiplying media is investigated employing the Telegrapher's equation obtained from the P 1 approximation of the time, space and energy dependent Boltzmann equation. Solution of the problem of propagation of sinusoidally modulated source incident on one face of the medium is obtained by analysing the Fourier component of a pulsed source introduced, for the corresponding frequency. The amplitude and the phase of the flux are computed as a function of frequency in media consisting of one, two and three regions in order to study the effects of reflection at the interfaces. The results are compared with those from the Diffusion approximation obtained by neglecting the term involving the second order time derivative. (author)

  10. High-performance instruments in neutron arena of JHP. Preliminary version

    International Nuclear Information System (INIS)

    Furusaka, M.; Itoh, S.; Otomo, T.; Arai, M.

    1996-05-01

    This report is a preliminary report of high-performance instruments in neutron arena of JHP (Japan Hadron Project). This report consists of as follows; neutron intensity of neutron arena, development of neutron sources in neutron arena, experimental devices and instrumentation. (J.P.N.)

  11. Measurement of cross sections for the scattering of neutrons in the energy range from 2 MeV to 4 MeV with the {sup 15}N(p,n) reaction as neutron source; Messung von Wirkungsquerschnitten fuer die Streuung von Neutronen im Energiebereich von 2 MeV bis 4 MeV mit der {sup 15}N(p,n)-Reaktion als Neutronenquelle

    Energy Technology Data Exchange (ETDEWEB)

    Poenitz, Erik

    2010-04-26

    In future nuclear facilities, the materials lead and bismuth can play a more important role than in today's nuclear reactors. Reliable cross section data are required for the design of those facilities. In particular the neutron transport in the lead spallation target of an Accelerator-Driven Subcritical Reactor strongly depends on the inelastic neutron scattering cross sections in the energy region from 0.5 MeV to 6 MeV. In the recent 20 years, elastic and inelastic neutron scattering cross sections were measured with high precision for a variety of elements at the PTB time-of-flight spectrometer. The D(d,n) reaction was primarily used for the production of neutrons. Because of the Q value of the reaction and the available deuteron energies, neutrons in the energy range from 6 MeV to 16 MeV can be produced. For the cross section measurement at lower energies, however, another neutron producing reaction is required. The {sup 15}N(p,n){sup 15}O reaction was chosen, as it allows the production of monoenergetic neutrons with up to 5.7MeV energy. In this work, the {sup 15}N(p,n) reaction was studied with focus on the suitability as a source for monoenergetic neutrons in scattering experiments. This includes the measurement of differential cross sections for the neutron producing reaction and the choice of optimum target conditions. Differential elastic and inelastic neutron scattering cross sections were measured for lead at four energies in the region from 2 MeV to 4 MeV incident neutron energy using the time-of-flight technique. A lead sample with natural isotopic composition was used. NE213 liquid scintillation detectors with well-known detection efficiencies were used for the detection of the scattered neutrons. Angle-integrated cross sections were determined by a Legendre polynomial expansion using least-squares methods. Additionally, measurements were carried out for isotopically pure {sup 209}Bi and {sup 181}Ta samples at 4 MeV incident neutron energy

  12. Production of neutron-rich nuclei in fission induced by neutrons generated by the p+ sup 1 sup 3 C reaction at 55 MeV

    CERN Document Server

    Stroe, L; Andrighetto, A; Tecchio, L B; Dendooven, P; Huikari, J; Pentillä, H; Peraejaervi, K; Wang, Y

    2003-01-01

    Cross-sections for the production of neutron-rich nuclei obtained by neutron-induced fission of natural uranium have been measured. The neutrons were generated by bombarding a sup 1 sup 3 C target with 55 MeV protons. The results, position of the maximum in the (Z, A)-plane, width and magnitude, are very comparable with those where the neutrons are generated by bombardment of natural sup 1 sup 2 C graphite with 50 MeV deuterons. Depending on the geometry of the converter/target assembly the isotope yields, however, are a factor of 2-3 lower due to less efficient production of neutrons per primary projectile, especially at small forward angles. (orig.)

  13. Production of DNA polymerase by recombinant pET-17b/Pfu-Pol ...

    African Journals Online (AJOL)

    Although this enzyme has been produced worldwide, there is no reported cloning or production of polymerases in Egypt. In the current work, plasmid coding Pfu polymerase enzyme (pET-17b/Pfu-Pol) was transformed into E. coli Top10. The plasmid coding Pfu- polymerase was confirmed by restriction analysis using HindIII ...

  14. Admittance studies of neutron-irradiated silicon p+-n diodes

    International Nuclear Information System (INIS)

    Tokuda, Y.; Usami, A.

    1977-01-01

    Defects introduced in n-type silicon by neutron irradiation were investigated by measuring the conductance (G) and the capacitance (C) of p + -n diodes. The method of the determination of the energy level, capture cross section, and concentration for each defect from the G-T and C-T curves for various frequencies was presented. Assuming that capture cross sections are independent of temperature, the energy levels of E/sub c/-0.15 eV, E/sub c/-0.22 eV, and E/sub c/-0.39 eV were obtained. For these defects, the calculated values of the electron capture cross section were 2.6 x 10 -14 , 3.7 x 10 -15 , and 2.0 x 10 -14 cm 2 , respectively. The introduction rate of defects for E/sub c/-0.39 eV was twice that for E/sub c/-0.22 eV which was twice that for E/sub c/-0.15 eV. Comparing with other published data, the energy levels of E/sub c/-0.15 eV and E/sub c/-0.39 eV were found to be correlated with the A center and the divacancy, respectively

  15. MicroRNA-181a-5p Impedes IL-17-Induced Nonsmall Cell Lung Cancer Proliferation and Migration through Targeting VCAM-1

    Directory of Open Access Journals (Sweden)

    Yang Cao

    2017-05-01

    Full Text Available Aim: The contribution of the inflammatory mediator interleukin-17 (IL-17 in nonsmall cell lung cancer (NSCLC malignancy has been reported in the literature. MicroRNA-181a-5p (miR-181a-5p acts as a tumor suppressor which can regulate target gene at the posttranscriptional level. Our study aimed to investigate the interaction between IL-17 and miR-181a-5p in NSCLC. Methods: 35 patients with NSCLC and 24 COPD controls were selected and examined in our study. In vitro, H226 and H460 cell lines were exposed to different doses (20, 40, 60, and 80 ng/mL of IL-17 to examine the effect of IL-17 on miR-181a-5p and vascular cell adhesion molecule 1 (VCAM-1 expression. MiR-181 mimic and miR-181a-5p inhibitor were transfected to explore the regulation of VCAM-1 as well as tumor cell proliferation and migration. Results: miR-181a-5p expression was downregulated, and IL-17 and VCAM-1 expression was upregulated in NSCLC tissues. Furthermore, IL-17 decreased miR-181a-5p expression but increased VCAM-1 expression in H226 and H460 cells. MiR-181 regulated VCAM-1 expression through binding to 3’-UTR sequence. MiR-181 attenuated tumor cell proliferation and migration. IL-17 modulated miR-181a-5p expression through activating NF-κB but not Stat3. Conclusion: Taken together, our data show the regulation of VCAM-1 expression by miR-181a-5p under IL-17 exposure, predicting a potential way for counteracting cancer metastasis.

  16. SSC-K code users manual (rev.1)

    International Nuclear Information System (INIS)

    Kwon, Y. M.; Lee, Y. B.; Chang, W. P.; Hahn, D.

    2002-01-01

    The Supper System Code of KAERI (SSC-K) is a best-estimate system code for analyzing a variety of off-normal or accidents in the heat transport system of a pool type LMR design. It is being developed at Korea Atomic Energy Research Institution (KAERI) on the basis of SSC-L, originally developed at BNL to analyze loop-type LMR transients. SSC-K can handle both designs of loop and pool type LMRs. SSC-K contains detailed mechanistic models of transient thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, coolant, fuel elements, and structures to accident conditions. This report provides a revised User's Manual (rev.1) of the SSC-K computer code, focusing on phenomenological model descriptions for new thermal, hydraulic, neutronic, and mechanical modules. A comprehensive description of the models for pool-type reactor is given in Chapters 2 and 3; the steady-state plant characterization, prior to the initiation of transient is described in Chapter 2 and their transient counterparts are discussed in Chapter 3. Discussions on the intermediate heat exchanger (IHX) and the electromagnetic (EM) pump are described in Chapter 4 and 5, respectively. A model of passive safety decay heat removal system (PSDRS) is discussed in Chapter 6, and models for various reactivity feedback effects are discussed in Chapter 7. In Chapter 8, constitutive laws and correlations required to execute the SSC-K are described. New models developed for SSC-K rev.1 are two dimensional hot pool model in Chapter 9, and long term cooling model in Chapter 10. Finally, a brief description of MINET code adopted to simulate BOP is presented in Chapter 11. Based on test runs for typical LMFBR accident analyses, it was found that the present version of SSC-K would be used for the safety analysis of KALIMER. However, the further validation of SSC-K is required for real applications. It is noted that the user's manual of SSC-K will be revised later with the

  17. n-p Short-Range Correlations from (p,2p+n) Measurements

    Science.gov (United States)

    Tang, A.; Watson, J. W.; Aclander, J.; Alster, J.; Asryan, G.; Averichev, Y.; Barton, D.; Baturin, V.; Bukhtoyarova, N.; Carroll, A.; Gushue, S.; Heppelmann, S.; Leksanov, A.; Makdisi, Y.; Malki, A.; Minina, E.; Navon, I.; Nicholson, H.; Ogawa, A.; Panebratsev, Yu.; Piasetzky, E.; Schetkovsky, A.; Shimanskiy, S.; Zhalov, D.

    2003-01-01

    We studied the 12C(p,2p+n) reaction at beam momenta of 5.9, 8.0, and 9.0 GeV/c. For quasielastic (p,2p) events pf, the momentum of the knocked-out proton before the reaction, was compared (event by event) with pn, the coincident neutron momentum. For |pn|>kF=0.220 GeV/c (the Fermi momentum) a strong back-to-back directional correlation between pf and pn was observed, indicative of short-range n-p correlations. From pn and pf we constructed the distributions of c.m. and relative motion in the longitudinal direction for correlated pairs. We also determined that 49±13% of events with |pf|>kF had directionally correlated neutrons with |pn|>kF.

  18. Thai Research Reactor (TRR-1/M1) Neutron Beam Measurements

    International Nuclear Information System (INIS)

    Ratanatongchai, Wichian

    2009-07-01

    Full text: Neutron beam tube of neutron radiography facility at Thai Research Reactor (TRR-1/M1) Thailand Institute of Nuclear Technology (public organization) is a divergent beam. The rectangular open-end of the beam tube is 16 cm x 17 cm while the inner-end is closed to the reactor core. The neutron beam size was measured using 20 cm x 40 cm neutron imaging plate. The measurement at the position 100 cm from the end of the collimator has shown that the beam size was 18.2 cm x 19.0 cm. Gamma ray in neutron the beam was also measured by the identical position using industrial X ray film. The area of gamma ray was 27.8 cm x 31.1 cm with the highest intensity found to be along the neutron beam circumference

  19. Measurements of prompt gamma-rays from fast-neutron induced fission with the LICORNE directional neutron source

    CERN Document Server

    Wilson, J N; Halipre, P; Oberstedt, S; Oberstedt, A

    2014-01-01

    At the IPN Orsay we have developed a unique, directional, fast neutron source called LICORNE, intended initially to facilitate prompt fission gamma measurements. The ability of the IPN Orsay tandem accelerator to produce intense beams of $^7$Li is exploited to produce quasi-monoenergetic neutrons between 0.5 - 4 MeV using the p($^7$Li,$^7$Be)n inverse reaction. The available fluxes of up to 7 × 10$^7$ neutrons/second/steradian for the thickest hydrogen-rich targets are comparable to similar installations, but with two added advantages: (i) The kinematic focusing produces a natural neutron beam collimation which allows placement of gamma detectors adjacent to the irradiated sample unimpeded by source neutrons. (ii) The background of scattered neutrons in the experimental hall is drastically reduced. The dedicated neutron converter was commissioned in June 2013. Some preliminary results from the first experiment using the LICORNE neutron source at the IPN Orsay are presented. Prompt fission gamma rays from fas...

  20. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    CERN Document Server

    Kumada, H

    2002-01-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to ...

  1. Studies with radioactive beams - properties of neutron halo

    International Nuclear Information System (INIS)

    Tanihata, I.

    1992-01-01

    Interaction cross sections σ I and 9 Li transverse momentum distributions of 11 Li reactions were measured using p, d, Be and C targets at 800 A and 400 A MeV. The density distribution of 11 Li nucleus has been determined, for the first time, combining the interaction cross sections with various targets and energies. It was confirmed that only the distribution with long tail describe the observed data. The momentum correlation of two neutrons in the neutron halo is extracted from the P T distribution of 9 Li and that of neutron. It is found that the two neutrons are moving in the same direction in average and thus strongly suggests a formation of di-neutron in 11 Li

  2. New results from the NA49 experiment on hadron production in p+p and p+C interactions and survey of backward hadrons in p+C collisions

    Directory of Open Access Journals (Sweden)

    Makariev M.

    2013-06-01

    Full Text Available Recent results on proton, anti-proton, neutron and charged kaon production in proton-proton and proton, anti-proton, neutron, deuteron and triton production in proton-carbon collisions at 158 GeV/c beam momentum are presented. Data samples of 4.8 million and 385 734 inelastic events in p+p and p+C, respectively, are obtained with the NA49 detector at the CERN SPS accelerator. The charged particles are identified by energy loss measurement in a system of four TPC chambers, while the neutrons are detected in a forward hadronic calorimeter. The data cover a major fraction of the phase space, ranging from 0 to 1.9 GeV in pT and in Feynman x variable from -0.8 to 0.95 for protons, from -0.2 to 0.3 for anti-protons, from 0.1 to 0.95 for neutrons and from 0 to 0.5 for kaons. The comparison of the results on proton and neutron production in p+p interactions and deep inelastic e+p collisions at HERA reveals an independence of target fragmentation on the projectile type. Using the charged kaon data in p+p collisions as a reference, a new evaluation of the energy dependence of kaon production, including neutral kaons, is conducted over a range from 3 GeV to p+p− collider energies. A survey of backward production of protons and pions in p+C collisions in the range of lab angles from 10 to 180 degrees, from 0.2 to 1.2 GeV/c in lab momentum and from 1 to 400 GeV/c in projectile momentum has been performed.

  3. Neutron radiography with the cyclotron, 3

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Fujishiro, Masatoshi; Tsujii, Yukio

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. A new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and equipped with vertical and horizontal irradiation ports, is presented in this article. A series of experiment, prior to its construction, was conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained, from 9 Be (p, n) reaction and thermalized by elastic scattering process. This article describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Some of practical neutron radiograph examination of aero-space components and museum art objects of classic bronze mirror are also presented together with an attempt realizing real time imaging technique. (author)

  4. Hair dosimetry following neutron irradiation.

    Science.gov (United States)

    Lebaron-Jacobs, L; Gaillard-Lecanu, E; Briot, F; Distinguin, S; Boisson, P; Exmelin, L; Racine, Y; Berard, P; Flüry-Herard, A; Miele, A; Fottorino, R

    2007-05-01

    Use of hair as a biological dosimeter of neutron exposure was proposed a few years ago. To date, the (32)S(n,p)(32)P reaction in hair with a threshold of 2.5 MeV is the best choice to determine the fast neutron dose using body activation. This information is essential with regards to the heterogeneity of the neutron transfer to the organism. This is a very important parameter for individual dose reconstruction from the surface to the deeper tissues. This evaluation is essential to the adapted management of irradiated victims by specialized medical staff. Comparison exercises between clinical biochemistry laboratories from French sites (the CEA and COGEMA) and from the IRSN were carried out to validate the measurement of (32)P activity in hair and to improve the techniques used to perform this examination. Hair was placed on a phantom and was irradiated at different doses in the SILENE reactor (Valduc, France). Different parameters were tested: variation of hair type, minimum weight of hair sample, hair wash before measurement, delivery period of results, and different irradiation configurations. The results obtained in these comparison exercises by the different laboratories showed an excellent correlation. This allowed the assessment of a dose-activity relationship and confirmed the feasibility and the interest of (32)P measurement in hair following fast neutron irradiation.

  5. DT fusion neutron irradiation of BPNL niobium nickel and 316 stainless steel at 1750C

    International Nuclear Information System (INIS)

    MacLean, S.C.

    1977-01-01

    The DT fusion neutron irradiation at 175 0 C of 17 niobium wires, one niobium foil, 14 316 stainless steel wires, one 316 stainless steel foil, nine nickel wires, and two nickel foils from BPNL is described. The sample position, beam-on time, neutron dose record, and neutron fluence are given

  6. Induced defects in neutron irradiated GaN single crystals

    International Nuclear Information System (INIS)

    Park, I. W.; Koh, E. K.; Kim, Y. M.; Choh, S. H.; Park, S. S.; Kim, B. G.; Sohn, J. M.

    2005-01-01

    The local structure of defects in undoped, Si-doped, and neutron irradiated free standing GaN bulk crystals, grown by hydride vapor phase epitaxy, has been investigated by employing Raman scattering and cathodoluminescence. The GaN samples were irradiated to a dose of 2 x 10 17 neutrons in an atomic reactor at Korea Atomic Energy Research Institute. There was no appreciable change in the Raman spectra for undoped GaN samples before and after neutron irradiation. However, a forbidden transition, A 1 (TO) mode, appeared for a neutron irradiated Si-doped GaN crystal. Cathodoluminescence spectrum for the neutron irradiated Si-doped GaN crystal became much more broadened than that for the unirradiated one. The experimental results reveal the generation of defects with locally deformed structure in the wurtzite Si-doped GaN single crystal

  7. Calibration of an electron volt neutron spectrometer

    International Nuclear Information System (INIS)

    Mayers, J.; Adams, M.A.

    2011-01-01

    The procedure for calibrating the VESUVIO eV neutron spectrometer at the ISIS neutron source is described. VESUVIO is used primarily to measure the momentum distribution n(p) of atoms, by inelastic scattering of very high energy (5-150 eV) neutrons. The results of the calibrations show that measurements of n(p) in atoms with masses lower than 16 amu can be measured with a resolution width ∼25% of the intrinsic peak widths in the current instrument configuration. Some suggestions as to how the instrument resolution could be significantly improved are made.

  8. Development of a reference spent fuel library of 17x17 PWR fuel assemblies

    International Nuclear Information System (INIS)

    Rossa, Riccardo; Borella, Alessandro; Van der Meer, Klaas

    2013-01-01

    One of the most common ways to investigate new Non-Destructive Assays (NDA) for the spent fuel assemblies are Monte Carlo simulations. In order to build realistic models the user must define in an accurate way the material compositions and the source terms in the system. This information can be obtained using burnup codes such as ORIGEN-ARP and ALEPH2.2, developed at SCK-CEN. These software applications allow the user to select the irradiation history of the fuel assembly and to calculate the corresponding isotopic composition and neutron/gamma emissions as a function of time. In the framework of the development of an innovative NDA for spent fuel verifications, SCK•CEN built an extensive fuel library for 17x17 PWR assemblies, using both ORIGEN-ARP and ALEPH2.2. The parameters considered in the calculations were initial enrichment, discharge burnup, and cooling time. The combination of these variables allows to obtain more than 1500 test cases. Considering the broad range of the parameters, the fuel library can be used for other purposes apart from spent fuel verifications, for instance for the direct disposal in geological repositories. In addition to the isotopic composition of the spent fuel, the neutron and photon emissions were also calculated and compared between the two codes. The comparison of the isotopic composition showed a good agreement between the codes for most of the relevant isotopes in the spent fuel. However, specific isotopes as well as neutron and gamma spectra still need to be investigated in detail.

  9. Prognostic significance of del 17p, ZAP-70 and CD38 as ...

    African Journals Online (AJOL)

    This study analyzed 40 recently diagnosed, untreated B-CLL patients for CD38 and ZAP-70 expression by flow cytometry and for del 17p by conventional cytogenetics (CCG) and by fluorescence in situ hybridization (FISH) technique to evaluate their effect on the clinical course of CLL and as risk factors for disease ...

  10. A new empirical formula for 14-15 MeV neutron-induced (n, p) reaction cross sections

    International Nuclear Information System (INIS)

    Tel, E; Sarer, B; Okuducu, S; Aydin, A; Tanir, G

    2003-01-01

    In this study, we have suggested a new empirical formula to reproduce the cross sections of the (n, p) reactions at 14-15 MeV for the neutron incident energy. This formula obtained using the asymmetry parameters represents a modification to the original formula of Levkovskii. The resulting modified formulae yielded cross sections, representing smaller χ 2 deviations from experimental values, and values much closer to unity as compared with those calculated using Levkovskii's original formula. The results obtained have been discussed and compared with the existing formulae, and found to be well in agreement, when used to correlate the available experimental σ(n, p) data of different nuclei

  11. Detection and measurement of neutron-irradiated gemstones

    International Nuclear Information System (INIS)

    Bunnak, S.; Jerachanchai, S.; Chinudomsub, K.; Saiyut, K.

    1990-01-01

    Color enhance gemstone, neutron-irradiated topaz, was analyzed by gamma spectrometry for examining characteristic and activity. Topaz was irradiated in the wet-tube facility of the Research Reactor TRR/1 which neutron fluence is 2.52x10 17 neutron per square centimeter. After 100 days of decay, topaz was sampling to the qualitative and quantitative analysis using multichannel analyzer of Nuclear Data Model ND65 and hyper pure germanium detector. Calculation and evaluation were done by microcomputer IBM/PC 640 KB RAM. The qualitative analysis showed that the neutron-irradiated topaz has 2 major isotopes, i.e., Ta-182 and Sc-46. Quantitative activity was compared with reference standard source Eu-152 (NBS) and the results were shown in the table 1. The Health Physics Division, OAEP, inspected on 6240.9 gm of the neutron-irradiated topaz using standard release limit 2 nCi/gm (74 Bq/gm). It was found that only 423.9 gm out of the total amount were over the standard release limit

  12. 17 CFR 240.12b-36 - Use of financial statements filed under other acts.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Use of financial statements... statements filed under other acts. Where copies of certified financial statements filed under other acts... manually signed or manually signed copies of the certificate shall be filed with the financial statements...

  13. MADNIX a code to calculate prompt fission neutron spectra and average prompt neutron multiplicities

    International Nuclear Information System (INIS)

    Merchant, A.C.

    1986-03-01

    A code has been written and tested on the CDC Cyber-170 to calculate the prompt fission neutron spectrum, N(E), as a function of both the fissioning nucleus and its excitation energy. In this note a brief description of the underlying physical principles involved and a detailed explanation of the required input data (together with a sample output for the fission of 235 U induced by 14 MeV neutrons) are presented. Weisskopf's standard nuclear evaporation theory provides the basis for the calculation. Two important refinements are that the distribution of fission-fragment residual nuclear temperature and the cooling of the fragments as neutrons are emitted approximately taken into account, and also the energy dependence of the cross section for the inverse process of compound nucleus formation is included. This approach is then used to calculate the average number of prompt neutrons emitted per fission, v-bar p . At high excitation energies, where fission is still possible after neutron emission, the consequences of the competition between first, second and third chance fission on N(E) and v-bar p are calculated. Excellent agreement with all the examples given in the original work of Madland and Nix is obtained. (author) [pt

  14. A practical contribution to the dosimetry of fast neutrons in radio-protection - determination of the integrated dose in man using the 32S(n, p)32P reaction (1963)

    International Nuclear Information System (INIS)

    Scheidhauer, J.; Chabidon, M.

    1963-01-01

    The problem of fast neutron dosimetry using activation is studied from the radio-protection point of view. The practical development of methods for analyzing phosphorus 32 produced by the activation of sulphur 32 in human hair by the reaction 32 S(n, p) 32 P is described. The sensitivity obtained is 5 rad. A preliminary study was made of the variations in the natural sulphur and phosphorus concentrations. (authors) [fr

  15. RE-EVALUATION OF THE NEUTRON EMISSION FROM THE SOLAR FLARE OF 2005 SEPTEMBER 7, DETECTED BY THE SOLAR NEUTRON TELESCOPE AT SIERRA NEGRA

    Energy Technology Data Exchange (ETDEWEB)

    González, L. X. [SCiESMEX, Instituto de Geofísica Unidad Michoacán, Universidad Nacional Autónoma de México, 58190, Morelia, Michoacán (Mexico); Valdés-Galicia, J. F.; Musalem, O.; Hurtado, A. [Instituto de Geofísica, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, 04510, D. F. Mexico (Mexico); Sánchez, F. [Instituto de Tecnologías en Detección de Astropartículas, Comisión Nacional de Energía Atómica, 1429, Buenos Aires (Argentina); Muraki, Y.; Sako, T.; Matsubara, Y.; Nagai, Y. [Solar-Terrestrial Environment Laboratory, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601 (Japan); Watanabe, K. [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, Yoshinodai, chuo-ku, Sagamihara 252-5210 (Japan); Shibata, S. [College of Engineering, Chubu University, Kasugai, Aichi 487-8501 (Japan); Sakai, T. [College of Industrial Technologies, Nihon University, Narashino 275-0005 (Japan)

    2015-12-01

    The X17.0 solar flare of 2005 September 7 released high-energy neutrons that were detected by the Solar Neutron Telescope (SNT) at Sierra Negra, Mexico. In three separate and independent studies of this solar neutron event, several of its unique characteristics were studied; in particular, a power-law energy spectra was estimated. In this paper, we present an alternative analysis, based on improved numerical simulations of the detector using GEANT4, and a different technique for processing the SNT data. The results indicate that the spectral index that best fits the neutron flux is around 3, in agreement with previous works. Based on the numerically calculated neutron energy deposition on the SNT, we confirm that the detected neutrons might have reached an energy of 1 GeV, which implies that 10 GeV protons were probably produced; these could not be observed at Earth, as their parent flare was an east limb event.

  16. D-T neutron skyshine experiments at JAERI/FNS

    Energy Technology Data Exchange (ETDEWEB)

    Nishitani, Takeo; Ochiai, Kentaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yoshida, Shigeo [Tokai Univ., Hiratsuka, Kanagawa (JP)] (and others)

    2003-03-01

    The D-T neutron skyshine experiments have been carried out at the Fusion Neutronics Source (FNS) of JAERI with the neutron yield of {approx}1.7x10{sup 11} n/s. The concrete thickness of the roof and the wall of a FNS target room are 1.15 and 2 m, respectively. The FNS skyshine port with a size of 0.9x0.9 m{sup 2} was open during the experimental period. The radiation dose rate outside the target room was measured as far as about 550 m away from the D-T target point with a spherical rem-counter. The highest neutron dose was about 0.5 {mu}Sv/hr at a distance of 30 m from the D-T target point and the dose rate was attenuated to 0.002 {mu}Sv/hr at a distance of 550 m. The measured neutron dose distribution was analyzed with Monte Carlo code MCNP-4B and a simple line source model. The MCNP calculation overestimates the neutron dose in the distance range larger than 250 m. The neutron spectra were evaluated with a {sup 3}He detector with different thickness of polyethylene neutron moderators. Secondary gamma-rays were measured with high purity Ge detectors and NaI scintillation detectors. (author)

  17. Allogeneic stem cell transplant in patients with chronic lymphocytic leukemia with 17p deletion: consult-transplant versus consult- no-transplant analysis.

    Science.gov (United States)

    Poon, Michelle L; Fox, Patricia S; Samuels, Barry I; O'Brien, Susan; Jabbour, Elias; Hsu, Yvonne; Gulbis, Alison; Korbling, Martin; Champlin, Richard; Abruzzo, Lynne V; Bassett, Roland L; Khouri, Issa F

    2015-03-01

    Allogeneic stem cell transplant (alloSCT) can overcome the adverse prognosis of chronic lymphocytic leukemia with 17p deletion (17p- CLL). However, its applicability remains unclear. Since 2007, our leukemia service has referred patients with 17p- CLL for alloSCT at presentation. In this study, the outcomes of these patients were reviewed retrospectively to determine whether they underwent alloSCT and why patients did not undergo alloSCT. Fifty-two patients with 17p- CLL who were referred to the transplant service from 2007 to 2010 were identified. Of these patients, 32 (62%) did not undergo alloSCT, mainly because of treatment- or disease-related complications (n = 15). The 2-year post-referral overall survival rates of the alloSCT and non-SCT groups were 64% and 25%, respectively (p = 0.001). These findings suggest that while alloSCT is an effective therapy in patients with 17p- CLL, pre-SCT complications may preclude a significant proportion of patients from undergoing the procedure.

  18. Cold neutron beam studies of parity-violation in the n-α and n-p systems

    International Nuclear Information System (INIS)

    Markoff, D.M.

    2001-01-01

    Long wavelength neutrons (λ>1 A) in a cold neutron beam provide a valuable probe to study the strong and weak nuclear forces in hadronic systems, where the description is complicated by the quark structure of the particles. As a consequence of parity-violation (PV) arising from the weak interaction, the low-energy neutron transverse spin-polarization vector rotates as the neutrons transverse a medium. The magnitude of the PV spin-rotation observable in the n-α system provides important new data to determine the strength of the neutron-nucleus weak interaction. Measurement of the spin-rotation in the bare neutron-proton system with a parahydrogen target, will provide important constraints on the weak nucleon-nucleon (NN) interaction including the neutral current contribution, and will increase our understanding of the strong NN interaction. This paper will review the recent spin-rotation measurement in a liquid helium target, and the proposed measurement in a parahydrogen target

  19. Neutron personal dosimetry in criticality accidents

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Mauricio, C.L.P.

    1996-01-01

    In the present work an innovating method is proposed to estimate the absorbed dose received by individuals irradiated with neutrons in an accident, even in the case that the victim is not using any kind of neutron dosemeter. The method combines direct measurements of 24 Na and 32 P activated in the human body. The calculation method was developed using data taken from previously published papers and experimental measurements. Other irradiations results in different neutron spectra prove the validity of the method here proposed. Using a whole body counter to measure 24 Na activity, it is possible to evaluate neutron absorbed doses in the order of 140 μ Gy of very soft (thermal) spectra. For fast neutron fields, the lower limit for neutron dose detection increases, but the present method continues to be very useful in accidents, with higher neutron doses. (author)

  20. What is the best frontline therapy for patients with CLL and 17p deletion?

    Science.gov (United States)

    Badoux, Xavier C; Keating, Michael J; Wierda, William G

    2011-03-01

    Chronic lymphocytic leukemia (CLL) is a lymphoproliferative disease with significant variation in disease progression, response to therapy, and survival outcome. Deletions of 17p or mutations of TP53 have been identified as one of the poorest prognostic factors, being predictive of short time for disease progression, lack of response to therapy, short response duration, and short overall survival. The treatment of patients with CLL has improved significantly with the development of chemoimmunotherapy, but this benefit was not pronounced in patients with 17p deletion. We compare various treatment strategies used in these patients, including FCR-like chemoimmunotherapy, alemtuzumab, other antibody combinations, or novel targeted therapies with promising results. Allogeneic stem cell transplantation offers the possibility for long-term disease control in these patients and should be considered early in younger, transplant-eligible patients. The current state of therapy is far from optimal and resources should be applied to studying therapeutic options for patients who have CLL with loss of p53 function.