WorldWideScience

Sample records for mammography crushed stone-like

  1. Breast cancer - Early detection with mammography. Crushed stone-like calcifications - The most frequent malignant type

    International Nuclear Information System (INIS)

    Tabar, Laszlo; Central Hospital, Falun; Tot, Tibor; Central Hospital, Falun; Dean, Peter B.

    2008-01-01

    A comprehensive guide for analyzing the most common malignant type calcifications on the mammogram Internationally renowned breast cancer imagers Laszlo Tabar and Peter B. Dean and the eminent breast pathologist Tibor Tot distill decades of clinical expertise in this new volume covering the most frequently occurring malignant type calcifications: the pleomorphic, crushed stone-like calcifications. The book presents a systematic approach to using mammographic features to distinguish different subtypes of breast diseases originating within the terminal ductal lobular unit (TDLU). More than 800 images demonstrate abnormal findings with superb clarity, providing a state-of-the-art visual reference for interpreting mammograms in the clinical setting. Features: - Concise descriptions of mammographic and MRI findings correlated with high-quality histopathologic images to provide a reliable guide for accurate diagnosis and differential diagnosis, as well as prognostic classification - Extensive coverage of all aspects of the benign differential diagnostic counterparts of pleomorphic calcifications, including fibrocystic change, fibroadenoma, and papilloma - Straightforward discussion of terminology based on a thorough analysis of subgross anatomy, 3D histologic features, and long-term disease outcomes - 3D viewing glasses enclosed in the book for perceiving specially marked images in their true 3D form This book is ideal for all breast imagers and breast pathologists, as well as for surgeons and oncologists specializing in breast diseases. For the radiologist, this book is an indispensable reference for harnessing the power of mammography to detect breast cancer at the earliest stages possible. About the Breast Cancer: Early Detection with Mammography series: This series grew out of the bestselling book Breast Cancer: The Art and Science of Early Detection with Mammography. Written by the same authors, this series is based on 30 years of experience with more than one

  2. Breast cancer - Early detection with mammography. Crushed stone-like calcifications - The most frequent malignant type

    Energy Technology Data Exchange (ETDEWEB)

    Tabar, Laszlo [Univ. of Uppsala (Sweden). School of Medicine]|[Central Hospital, Falun (Sweden). Dept. of Mammography; Tot, Tibor [Univ. of Uppsala (Sweden). School of Medicine]|[Central Hospital, Falun (Sweden). Dept. of Pathology and Clinical Cytology; Dean, Peter B. [Turku Univ. (Finland). Dept. of Diagnostic Radiology

    2008-07-01

    A comprehensive guide for analyzing the most common malignant type calcifications on the mammogram Internationally renowned breast cancer imagers Laszlo Tabar and Peter B. Dean and the eminent breast pathologist Tibor Tot distill decades of clinical expertise in this new volume covering the most frequently occurring malignant type calcifications: the pleomorphic, crushed stone-like calcifications. The book presents a systematic approach to using mammographic features to distinguish different subtypes of breast diseases originating within the terminal ductal lobular unit (TDLU). More than 800 images demonstrate abnormal findings with superb clarity, providing a state-of-the-art visual reference for interpreting mammograms in the clinical setting. Features: - Concise descriptions of mammographic and MRI findings correlated with high-quality histopathologic images to provide a reliable guide for accurate diagnosis and differential diagnosis, as well as prognostic classification - Extensive coverage of all aspects of the benign differential diagnostic counterparts of pleomorphic calcifications, including fibrocystic change, fibroadenoma, and papilloma - Straightforward discussion of terminology based on a thorough analysis of subgross anatomy, 3D histologic features, and long-term disease outcomes - 3D viewing glasses enclosed in the book for perceiving specially marked images in their true 3D form This book is ideal for all breast imagers and breast pathologists, as well as for surgeons and oncologists specializing in breast diseases. For the radiologist, this book is an indispensable reference for harnessing the power of mammography to detect breast cancer at the earliest stages possible. About the Breast Cancer: Early Detection with Mammography series: This series grew out of the bestselling book Breast Cancer: The Art and Science of Early Detection with Mammography. Written by the same authors, this series is based on 30 years of experience with more than one

  3. Automation for Crushing and Screening Equipment to Produce Graded Paving Crushed Stone

    Science.gov (United States)

    Tikhonov, Anatoly; Velichkin, Vladimir

    2017-10-01

    This paper offers analysis of factors related to production and storage of graded crushed stone, which adversely impact the service life and wear resistance of asphalt-concrete motor road pavements. The paper describes external and technology-related parameters that may cause changes of the preset ratio in graded crushed stone. Control factors are described that ensure the formulated fraction ratio in crushed stone by controlling the operation mode of the crushing and screening equipment. The paper also contains an ACS flow chart for crushing and screening equipment engaged in continuous closed-cycle two-stage technology. Performance of the ACS to maintain the preset fractionated crushed stone ratio has been confirmed with a mathematical model.

  4. Crushed Stone Operations

    Data.gov (United States)

    Department of Homeland Security — This map layer includes crushed stone operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  5. Crushed stone production plant for NPP building

    International Nuclear Information System (INIS)

    Obolenskij, V.Ya.

    1982-01-01

    The project of the granite-crushed stone quarry - the large modern plant producing building materials, is presented. The quarry is designated for providing NPP and other power objects building with high-strength crushed stone. The plant consists of: quarry; crushing-sorting plant with maintenance objects arranged on its ground; basis and service stores of explosive materials; tail facility and purifying systems; water supply purifying stations; water storage basin. The plant is reserved for 2335 thousand m 3 yearly utoput of crushed stone; the staff consists of 535 persons, the budgeted cost of building is 26.6 million rubles. Physicochemical characteristics of granosyenites of the ''Granitnoye'' deposit - the raw material resource base of the plant and technological scheme of the crushing-sorting plant are given. Planned measures on building organization and recultivation of disturbed grounds are presented

  6. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Safety and health in the stone crushing industry : a practical manual for preventing accidents preserving health and keeping a company profitable. Études. Abstract for oral presentation : addressing health risk of communities residing close to stone quarrying and crushing unit using ecohealth framework in Central India.

  7. [Hygienic assessment of metal-lurgical slag crushed stone for its use in road-building].

    Science.gov (United States)

    Tikhomirov, Iu P; Ippolitova, V P; Bezrokov, M E

    2010-01-01

    The increasing amount of industrial waste generates a need for its use as recycled materials. The paper presents the results of hygienic assessment of metallurgic slag crushed stone to be added to natural materials in highway building. The research program has included the measurement of content of water-soluble forms of metals, the evaluation of the acute toxicity of waste after oral administration to mice and rats, the study of the toxicity of waste by biotesting and the activity of natural radionuclides. The slag crushed stone virtually lacks water-soluble elements when it contains a high level of bulk forms of metals. According to acute toxicity for warm-blooded animals, the slag crushed stone belongs to Hazard Class IV by GOST 12.1.007-76 (low hazard substances). The biotesting on hydrocoles, the slag crushed stone is also referred to as Class IV (low hazard substances). In terms of the level of natural radionuclides, the slag crushed stone poses no hazard to the environment. The performed studies give grounds to recommend metallurgical slag crushed stone to be added to natural materials for highway building.

  8. Research of environmentally-friendly utilization methods of the crushed stone waste on granite quarries

    Directory of Open Access Journals (Sweden)

    Levytskyi V.G.

    2017-12-01

    Full Text Available The analysis of activity of stone-mining enterprises shows the low competitiveness of crushed stone products Upgrading the quality of crushed stone and production of the European standard fractions requires to use of new technologies and equipment. The main waste of crushed stone pits is сrushed granite waste, which high percent of an exit is caused by outdated equipment and incorrectly selected technological parameters of the crushing process. Crushed-granite waste is stored in dumps which occupy large areas and negatively effect on production area ecology. In November 2017, the Government of Ukraine accepted the National Waste Management Strategy until 2030, the main aim of it is develop a strategy of the mineral raw materials balanced use and international standards introduction at the national level. Therefore, the problem of complex utilization and recycling of waste from stone-mining enterprises with receiving a qualitative secondary product is relevant. The publication presents the сrushed granite waste volumes by crushed stone pit, its properties and main directions of utilization. The ecological influence of waste dumps, in particular granite dust, on the environment and human, the strategy of using non-waste technologies and ecological features of сrushed granite waste secondary processing are considered

  9. Geo-Engineering Evaluation of Rock Masses for Crushed Rock and Cut Stones in Khartoum State, Sudan

    Science.gov (United States)

    Kheirelseed, E. E.; Ming, T. H.; Abdalla, S. B.

    The purpose of this study is to find artificial coarse aggregates and cut stones around Khartoum. To meat the objectives of the study, data from both field and laboratory are collected. The field data includes geological investigations based on different methods and samples collection, whereas the laboratory tests consists of specific gravity, water absorption, impact value, crushing value, Los Angeles abrasion, soundness tests. The field and laboratory results were weighed and compiled together to reveal the engineering performance of the different rock masses in term of cut stone and crushed aggregates. The results show that most of the examined rock masses are suitable for crushing, building and dressed stones. For decorative slabs only foliated granite and syenite masses can be used.

  10. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya ... In the context of weak regulatory enforcement, worksite health and safety ... in stone quarrying and crushing through better ecosystem management. ... India, Central Asia, Far East Asia, South Asia ... LVIF announces five more funded projects.

  11. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya Pradesh), stone quarrying and crushing is carried out by labor-intensive units employing unskilled workers on a seasonal basis complementing the agricultural cycle. In the context of weak regulatory enforcement, worksite health and safety ...

  12. Mitigating the Health Risks of Stone Quarrying and Crushing in India ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya ... In the context of weak regulatory enforcement, worksite health and safety measures are not ... involved in stone quarrying and crushing through better ecosystem management. ... et les défis futurs dans la communauté économique de l'ASEAN.

  13. Early occupational hearing loss of workers in a stone crushing industry: our experience in a developing country.

    Science.gov (United States)

    Kitcher, Emmanuel D; Ocansey, Grace; Tumpi, Daniel A

    2012-01-01

    Noise-induced hearing loss (NIHL) is an irreversible sensorineural hearing loss associated with exposure to high levels of excessive noise. This paper aims to assess the prevalence of early NIHL and the awareness of the effects of noise on health among stone crushing industry workers. This was a comparative cross-sectional study in Ghana of 140 workers from the stone crushing industry compared with a control group of 150 health workers. The stone workers and controls were evaluated using a structured questionnaire, which assessed symptoms of hearing loss, tinnitus, knowledge on the health hazards associated with work in noisy environment and the use of hearing protective device. Pure tone audiometric assessment was carried out for stone workers and controls. Noise levels at the work stations of the stone workers and of the controls were measured. Statistical Analysis of data was carried out using SPSS package version 16. The mean age of stone workers and controls was 42.58±7.85 and 42.19±12 years, respectively. Subjective hearing loss occurred in 21.5% of the workers and in 2.8% of the controls. Tinnitus occurred in 26.9% of stone workers and 21.5% of controls, while 87.5% stone workers had sound knowledge on the health hazards of a noisy environment. Early NIHL in the left ear occurred in 19.3% of the stone workers compared with 0.7% in controls and in the right ear, it occurred in 14.3% of the stone workers and in 1.3% of the controls; Pstone crushing workers is about 19.3% for the left ear and 14.3% for the right ear.

  14. Early occupational hearing loss of workers in a stone crushing industry: Our experience in a developing country

    Directory of Open Access Journals (Sweden)

    Emmanuel D Kitcher

    2012-01-01

    Full Text Available Noise-induced hearing loss (NIHL is an irreversible sensorineural hearing loss associated with exposure to high levels of excessive noise. This paper aims to assess the prevalence of early NIHL and the awareness of the effects of noise on health among stone crushing industry workers. This was a comparative cross-sectional study in Ghana of 140 workers from the stone crushing industry compared with a control group of 150 health workers. The stone workers and controls were evaluated using a structured questionnaire, which assessed symptoms of hearing loss, tinnitus, knowledge on the health hazards associated with work in noisy environment and the use of hearing protective device. Pure tone audiometric assessment was carried out for stone workers and controls. Noise levels at the work stations of the stone workers and of the controls were measured. Statistical Analysis of data was carried out using SPSS package version 16. The mean age of stone workers and controls was 42.58±7.85 and 42.19±12 years, respectively. Subjective hearing loss occurred in 21.5% of the workers and in 2.8% of the controls. Tinnitus occurred in 26.9% of stone workers and 21.5% of controls, while 87.5% stone workers had sound knowledge on the health hazards of a noisy environment. Early NIHL in the left ear occurred in 19.3% of the stone workers compared with 0.7% in controls and in the right ear, it occurred in 14.3% of the stone workers and in 1.3% of the controls; P<0.005. In conclusion, the prevalence rate of early NIHL among stone crushing workers is about 19.3% for the left ear and 14.3% for the right ear.

  15. Determination of exposure to respirable quartz in the stone crushing units at Azendarian-West of Iran.

    Science.gov (United States)

    Bahrami, Abdul Rahman; Golbabai, Faridah; Mahjub, Hossien; Qorbani, Farshid; Aliabadi, Mohsan; Barqi, Mohamadali

    2008-08-01

    The purpose of this study is to describe the personal exposure to respirable dust and quartz and in stone crushing units located at west of Iran. A size of 40 personal samples and 40 stationary samples were obtained and analysis was done by X-ray diffraction (XRD). The results of personal sampling were shown the concentrations of respirable dust exposure level in workers of process, hopper and drivers were 1.90, 2.22, 1.41 times greater than Occupational Safety and Health Administration permissible exposure limit (OSHA PEL). The average value of total dust and respirable dust emission from stationary sources was 9.46 mg/m(3), 1.24 mg/m(3) respectively, showing that 13.8 % of total dust is respirable. The efficiency of local exhaust ventilation (LEV) to control of particles inside of industrial units was greater than 99%. It is concluded from this research the particulate generated from stone crushing activities contain a significant amount of respirable particle. The amount of free silica in stone quartz is 85 to 97 percent that emission of particles effect to health workers. LEV has important effect in the removal of silica particles in stone crushing units. The worker of hoppers still exposed to silica more than standard limits.

  16. Study on the Elasticity-Plasticity-Stickiness of the Railway Crushed Stone Ballast

    Institute of Scientific and Technical Information of China (English)

    Gao Liang

    2004-01-01

    This paper is mainly aimed at the mechanics characteristic elas of ticity-plasticitystickiness existed in the CWR (continuously welded rails) track plane of the railway crushed stone ballast. As an important mechanics parameter of the CWR track plane, the ballast resistance is mainly influenced by this mechanics characteristic. Through the systematic experimental research and the theoretical analysis, this mechanics characteristic of the ballast resistance is revealed and a reasonable theoretical model is built for it. This study set a sound foundation for further studying the CWR track deformation property. It will be beneficial to the development of high-speed railway in China.

  17. Studies on various characteristics of concrete structures using crushed sand

    International Nuclear Information System (INIS)

    Mimatsu, Makoto; Sugita, Hideaki; Yonemura, Masataka.

    1985-01-01

    With the recent advances of construction industry, the demands for concrete, hence for aggregate, are rising. The sand as such is in extreme shortage due to the exhaustion of river sand. Under the situation, the recent trends are for the use of crushed sand, i.e. the artificial sand obtained by crushing rocks, which have advantages of stabilized quality and adequate supplies. In building of nuclear power plants requiring large amounts of concrete, the usage of crushed sand is now unavoidable. The following are described : the situation of aggregate in Kyushu. production method of crushed sand and the quality standards, rocks used for crushed stone and sand and the properties, quality survey on crushed sand and the basic tests, characteristic tests of crushed-stone and -sand mixed concrete, the application of crushed sand in structures of the Sendai Nuclear Power Station. (Mori, K.)

  18. Percutaneous suprapubic stone extraction for posterior urethral stones in children: efficacy and safety.

    Science.gov (United States)

    Safwat, Ahmed S; Hameed, Diaa A; Elgammal, Mohamed A; Abdelsalam, Yasser M; Abolyosr, Ahmad

    2013-08-01

    To evaluate the safety and efficacy of percutaneous suprapubic stone extraction (PSPSE) for pediatric posterior urethral stones. Between July 2007 and June 2010, 54 boys presenting with acute urinary retention due to posterior urethral stones underwent PSPSE. Patients were a mean age of 66.4 months (range, 8-180 months). The stone size was 0.7-1.9 cm. Patients were placed under general anesthesia, and a 7F urethroscope was used to pushback the stone to the bladder. A 3-mm suprapubic puncture with a scalpel was performed, followed by insertion of a straight narrow hemostat through the puncture aided with cystoscopic guidance. The stone was grasped with the hemostat in its narrowest diameter and was extracted percutaneously or crushed if friable. The suprapubic puncture was closed with a single 4-0 Vicryl (Ethicon) suture. Intact stone retrieval was achieved in 45 patients, and the stone was crushed into minute fragments in 9 patients. Intraperitoneal extravasation developed in 1 patient that required open surgical intervention. Mean operative time was 22 minutes. Patients were monitored for up to 17 months, with complete resolution of symptoms and stone clearance. PSPSE provides a minimally invasive approach for the extraction of urethral and bladder stones in the pediatric population. The use of a straight hemostat for suprapubic stone extraction or crushing is a good alternative to suprapubic tract dilation, with minimal morbidity. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Usage of Crushed Concrete Fines in Decorative Concrete

    Science.gov (United States)

    Pilipenko, Anton; Bazhenova, Sofia

    2017-10-01

    The article is devoted to the questions of usage of crushed concrete fines from concrete scrap for the production of high-quality decorative composite materials based on mixed binder. The main problem in the application of crushed concrete in the manufacture of decorative concrete products is extremely low decorative properties of crushed concrete fines itself, as well as concrete products based on them. However, crushed concrete fines could have a positive impact on the structure of the concrete matrix and could improve the environmental and economic characteristics of the concrete products. Dust fraction of crushed concrete fines contains non-hydrated cement grains, which can be opened in screening process due to the low strength of the contact zone between the hydrated and non-hydrated cement. In addition, the screening process could increase activity of the crushed concrete fines, so it can be used as a fine aggregate and filler for concrete mixes. Previous studies have shown that the effect of the usage of the crushed concrete fines is small and does not allow to obtain concrete products with high strength. However, it is possible to improve the efficiency of the crushed concrete fines as a filler due to the complex of measures prior to mixing. Such measures may include a preliminary mechanochemical activation of the binder (cement binder, iron oxide pigment, silica fume and crushed concrete fines), as well as the usage of polycarboxylate superplasticizers. The development of specific surface area of activated crushed concrete fines ensures strong adhesion between grains of binder and filler during the formation of cement stone matrix. The particle size distribution of the crushed concrete fines could achieve the densest structure of cement stone matrix and improve its resistance to environmental effects. The authors examined the mechanisms of structure of concrete products with crushed concrete fines as a filler. The results of studies of the properties of

  20. SHAPING AND REDESTINATION OF EXCAVATED AREAS IN THE COURSE OF THE EXPLOITATION OF CRUSHED STONE

    Directory of Open Access Journals (Sweden)

    Jerko Nuić

    1997-12-01

    Full Text Available In the construction of devastated and demolished country the want for crushed stone is ever more greater. The opening of new quarryes is subject to strict ecological norms. The location of activity as well as the concept of the mining works represent a matter of consideration. Excavated areas should be shaped in a way to be integrated into immediate and wider environment most conveniently and then be redestinated with the purpose of the economic, sporting-recreation or some other usage. On the existing model in nature (»Široki Čelac« quarry, Novalja on the island of Pag, the specific characteristics of the locality and region have been respected. There have been also given adequate solutions for a possible deposit of communal waste (the paper is published in Croatian.

  1. Investigating the swelling pressure of compacted crushed-Callovo-Oxfordian clay-stone

    International Nuclear Information System (INIS)

    Tang, C. S.; Tang, A. M.; Cui, Y. J.; Delage, P.; Schroeder, C.; De Laure, E.

    2011-01-01

    This paper presents an experimental study on the swelling pressure of heavily compacted crushed Callovo-Oxfordian (COx) clay-stone at a dry unit mass ρ d =2.0 Mg/m 3 using four different methods: constant-volume, swell-reload, zero-swell and adjusted constant-volume method. Results show that the swelling pressure varies in the range of 1-5 MPa and depends significantly on the test method. From the constant-volume tests, it is observed that the swelling behavior during wetting is a function of the suction and depends on both the hydration paths and wetting conditions (e.g. vapor-wetting or liquid-wetting). The swelling pressure decreases significantly with saturation time. To identify the microstructure changes of specimens before and after wetting, mercury intrusion porosimetry (MIP) and scanning electron microscopy (SEM) tests were performed. It is observed that, after wetting, the large inter-aggregate pores observed in the as-compacted specimen are no longer apparent; the whole pattern is characterized by a general swell of hydrated clay particles, rendering the soil more homogenous. Results from MIP indicated that wetting caused a significant reduction of the entrance diameter of the dominant inter-aggregate pores from 2.1 to 0.5μm whereas intra-aggregate pores were not significantly influenced. (authors)

  2. A comparative study of mud-like and coralliform calcium carbonate gallbladder stones.

    Science.gov (United States)

    Ma, Rui-Hong; Luo, Xiao-Bing; Wang, Xiao-Feng; Qiao, Tie; Huang, Hai-Yi; Zhong, Hai-Qiang

    2017-07-01

    To gain insight to underlying mechanism of the formation of calcium carbonate (CaCO 3 ) gallbladder stones, we did comparative study of stones with mud appearance and those with coralliform appearance. A total of 93 gallbladder stones with mud appearance and 50 stones with coralliform appearance were analyzed. The appearance, color, texture, and the detection of Clonorchis sinensis eggs by microscopic examination were compared between the two groups. Then, the material compositions of stones were analyzed using Fourier Transform Infrared spectroscopy and the spectrogram characteristics were compared. Moreover, microstructure characteristics of the two kinds of stones were observed and compared with Scanning Electron Microscopy. Mud-like gallbladder stones were mainly earthy yellow or brown with brittle or soft texture, while coralliform stones were mainly black with extremely hard texture, the differences between the two groups was significant (p mud-like gallbladder stones were CaCO 3 stones, and mainly aragonite; while all of the coralliform stones were CaCO 3 stones, and mainly calcite (p mud-like CaCO 3 stones was lower than that in coralliform CaCO 3 stones (p Mud-like CaCO 3 stones mainly happened to patients with cystic duct obstruction. Clonorchis sinensis infection was mainly associated with coralliform (calcite) CaCO 3 stones. Cystic duct obstruction was mainly associated with mud-like (aragonite) CaCO 3 stones. © 2017 Wiley Periodicals, Inc.

  3. Transcystic duct treatment of common bile duct stones

    International Nuclear Information System (INIS)

    Amberg, J.R.; Chun, G.

    1981-01-01

    Successful removal of 2 retained common bile duct stones following cholecystostomy is described. With the use of the steerable catheter and the wire basket, one stone was crushed and the second was extracted in retrograde fashion through the cystic duct and gallbladder. (orig.)

  4. Application of Crushed Concrete in Geotechnical Engineering - Selected Issues

    Science.gov (United States)

    Kawalec, Jacek; Kwiecien, Slawomir; Pilipenko, Anton; Rybak, Jarosław

    2017-12-01

    The reuse of building materials becomes an important issue in sustainable engineering. As the technical requirements for civil engineering structures changes with time and the life time is limited, the need of building new objects meets the necessity of recycling of the existing ones. In the case of steel structures, the possibility of recycling is obvious, also in the case of wooden constructions, the possibility of “burning” solves the problem. The concrete waste is generated mainly as a result of the demolition and reconstruction of residential and industrial buildings. These types of waste are basically made from crushed rocks and cement minerals and contain non-hydrated cement particles in its composition. Concrete poses a lot of problems mainly for two reasons. It is difficult to crush, heavy and hard to transport and demanding in reuse. Different fractions (particle sizes) may be used for different purposes. Starting from very fine particles which can be used in concrete production, through regular 16-300 mm fractions used to form new fills and fill the mats, up to very irregular mixtures used to form stone columns by means of Impulse Compaction or in Dynamic Replacement. The presented study juxtaposes authors experience with crushed concrete used in civil engineering, mainly in geotechnical projects. Authors’ experiences comprise the application of crushed concrete in the new concrete production in Russia, changing pulverized bridge into the fill of mesh sacks, or mattresses used as an effective way to protect the shoreline and the New Orleans East land bridge after Katrina storm (forming a new shoreline better able to withstand wave actions), and finally the use of very irregular concrete fractions to form stone columns in week soils on the example of railway and road projects in Poland. Selected case studies are presented and summarized with regard to social, technical and economic issues including energy consumption needed for proposed technologies

  5. Crushed rock sand – An economical and ecological alternative to natural sand to optimize concrete mix

    Directory of Open Access Journals (Sweden)

    Sanjay Mundra

    2016-09-01

    Full Text Available The study investigates the use of crushed rock sand as viable alternative to Natural River sand that is being conventionally used as fine aggregate in cement concrete. Various mix designs were developed for different grades of concrete based on IS, ACI and British codes using Natural River sand and crushed rock sand. In each case, the cube compressive strength test, and beam flexure tests were conducted. The results of the study show that, the strength properties of concrete using crushed rock sand are nearly similar to the conventional concrete. The study has shown that crushed stone sand can be used as economic and readily available alternative to river sand and can therefore help to arrest the detrimental effects on the environment caused due to excessive mining of river sand.

  6. Mix proportioning and performance of a crushed limestone sand-concrete

    OpenAIRE

    Makhloufi Zoubir; Bouziani Tayeb; Bédérina Madani; Hadjoudja Mourad

    2014-01-01

    Satisfying the ever-growing demand of concrete aggregates poses a problem in many parts of the world due to shortage of natural sand. Moreover, to conserve natural resources and protect civil engineering infrastructures, there is a need to find alternative materials. Crushed stone sand has been identified as a potential substitute material for natural sand in making good quality concrete. The main objective of the present investigation is to determine an adequate mix design method and evaluat...

  7. The self-referred mammography patient

    International Nuclear Information System (INIS)

    Reynolds, H.E.; Jackson, V.P.

    1990-01-01

    This paper compares the demographics, knowledge, and attitudes of women who refer themselves for screening mammography with those who undergo mammography on the advice of their physicians. Four hundred eighty-five consecutive mammography patients (437 doctor preferred [DR], 48 self-referred [SR]) completed a survey during their mammography appointment. The sample population contained a wide range of socioeconomic groups. While similar in age, race, and employment status to DR patients, SR patients were significantly more likely to have a family income of more than 30,000 per year, be college graduates, and report that they were in good or excellent health

  8. Crushed aggregates for roads and their properties for frost protection

    Science.gov (United States)

    Kuznetsova, Elena; Willy Danielsen, Svein

    2015-04-01

    Crushed aggregates for roads and their properties for frost protection Elena Kuznetsova, NTNU and Svein Willy Danielsen, SINTEF With natural (fluvial, glaciofluvial) sand/gravel resources being rapidly depleted in many countries, the last decade has seen a significant trend towards using more alternative materials for construction purpose. In Norway the development and implementation of crushed aggregate technology has been the most important way to get around the problem with increased resource scarcity. Today Norway is one the European countries with the highest percentage of crushed/manufactured aggregates. A crushed product will reveal a different particle size distribution, a sharper, more angular particle shape, and not least - a significantly different mineral composition. The latter may often be characterised by more polymineral composition, and it will also much more depend on the local bedrock. When handled with care and knowledge, these differences can give the user a lot of new opportunities relating to materials design. Norwegian road construction practice has changed significantly during the last 40 years due to the replacement of gravel by crushed rock materials in the granular layers of the pavements. The use of non-processed rock materials from blasting was allowed in the subbase layer until 2012. This was a reason for a lot of problems with frost heaving due to inhomogeneity of this material, and in practice it was difficult to control the size of large stones. Since 2012 there is a requirement that rock materials for use in the subbase layer shall be crushed (Handbook N200, 2014). During the spring 2014 The Norwegian Public Roads Administration introduced a new handbook with requirements for roads construction in Norway, including new specifications for the frost protection layer. When pavements are constructed over moist and/or frost susceptible soils in cold and humid environments, the frost protection layer also becomes a very important part

  9. Family/Friend Recommendations and Mammography Intentions: The Roles of Perceived Mammography Norms and Support

    Science.gov (United States)

    Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.

    2015-01-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography…

  10. In vitro dissolution of calcium oxalate stones with ethylenediaminetetraacetic acid and snake venom thrombin-like enzyme.

    Science.gov (United States)

    Zhou, Xiang-Jun; Zhang, Jie; Zhang, Ci; Xu, Chang-Geng

    2014-01-01

    The aim of this study was to determine the feasibility of using snake venom thrombin-like enzyme (SVTLE) and/or ethylenediaminetetraacetic acid (EDTA) to dissolve calcium oxalate stones in vitro. Seven calcium oxalate stones were incubated with various chemolytic agents [EDTA, Tris-HCl/EDTA (TE) buffer or SVTLE diluted in TE buffer]. The pH, calcium concentration, stone weight and stone surface integrity were recorded, as well as related pathological changes to bladder mucosae. Compared to all other solutions, those containing SVTLE and buffered EDTA had higher concentrations of mobilized calcium and caused significantly more stone weight loss, stone fragility and gaps in the calcium crystals. Also, there were no adverse pathological effects on rabbit bladder mucosae from any of the solutions. The data indicate that buffered EDTA and SVTLE can be used to dissolve calcium oxalate stones and, at the concentrations used here, do not damage tissue. 2013 S. Karger AG, Basel.

  11. DK crush (double-kissing and double-crush) technique for treatment of true coronary bifurcation lesions: illustration and comparison with classic crush.

    Science.gov (United States)

    Chen, Shaoliang; Zhang, Junjie; Ye, Fei; Zhu, Zhongsheng; Lin, Song; Shan, Shoujie; Kwan, Tak W

    2007-04-01

    Classic crush has a lower success rate compared to final kissing balloon inflation (FKBI). We previously reported the double-kissing (DK) crush technique that involves double-kissing along with double-crushing for the treatment of true bifurcation coronary lesions in 2005. This is a consecutive, nonrandomized, open-label study. Eighty-eight consecutive patients with single, true coronary bifurcation lesions according to Lefevre Classification2 and side branch diameter >2.0 mm were enrolled. The first 44 patients (from October 2004 to January 2005) were assigned to the classic crush treatment arm and the next 44 patients (from February 2005 to June 2005) were assigned to the DK crush technique arm, respectively. Data within 30 days were analyzed. Patients in the DK crush group, compared to those in classic crush group, were characterized by longer lesion length in the side branch (13.5 +/- 3.4 mm vs 7.8 +/- 3.1 mm; p DK crush group, as well as longer lesion length in the main vessel (24.3 +/- 8.6 mm vs 21.1 +/- 7.3 mm), though without significant differences (p >0.05). Subacute stent thrombosis was detected in 2 patients with failure of FKBI in the classic crush group (4.3%). In addition, patients in the classic crush group were characterized by a smaller minimum lumen diameter (MLD) at the side branch ostium (2.74 +/- 0.12 mm vs 3.01 +/- 0.13 mm; p DK crush has the potential to improve the clinical outcome in patients with coronary bifurcation lesions. Further randomized, prospective, multicenter studies are required to confirm these differences between the classic crush and DK crush techniques.

  12. A new method for controlling of floor heave of deep tunnels in soft rocks by mini-tube grouting piles of crushed stones%微型碎石管注桩治理深部软岩巷道底鼓新方法

    Institute of Scientific and Technical Information of China (English)

    谢芳; 王金安

    2013-01-01

    针对造成巷道底鼓的物理和力学两种重要机制,研究并提出微型碎石管注桩治理深部软岩巷道底鼓的新方法.在物理机制方面,微型碎石桩具有渗透性极好的特点,在巷道施工和使用期间可汲取岩体中的渗水并透过碎石桩中的插管排出,从而降低软岩层因遇水膨胀导致的变形;在力学机制方面,微型碎石桩一方面通过钻孔置换出少部分底板软岩,从体量上减少变形岩体,另一方面能利用碎石桩体的侧向可压缩性耗散岩体水平变形,底板岩层中的水平地应力得以释放,极大减缓了促使底鼓变形的力学作用;通过微型碎石桩中的插管注浆加固底板岩体,提高了底板复合地基整体承载力.通过数值分析,阐明该方法在治理软岩巷道底鼓机制上的有效性.%Focusing on two important mechanisms of physics and mechanics that give rise to the floor heave of tunnels , a new method of controlling the floor heave of deep tunnels in soft rocks was proposed by means of mini-tube grouting piles of crushed stones. In physical aspect, the method utilizes the characteristics of good permeability of crushed stone pile to absorb the water in rockmass and drainage out through the tubes in the pile during the construction and application of the tunnels, resulting in the decrease in expansion deformation of soft rock due to water saturation. In mechanical aspect, partial volume in floor stratum has been replaced, on one hand, by the installed mini piles which reduce the volume of the deforming rock body, and on the other hand, amount of horizontal deformation are dissipated through the lateral compressive deformation of the crushed stone pile, and the horizontal stress is released. As a result, the mechanical affect that induces the heave deformation in floor stratum is considerably reduced. By means of grouting the crushed stones through the tube inserted in the pile, the floor stratum is reinforced and the

  13. Crush Grinding

    International Nuclear Information System (INIS)

    Nguyen, T.Q.

    2005-01-01

    Crush Grinding is a special process used at the Kansas City Plant to finish stem sections of reservoir products. In this process, a precise profile of the desired product is formed on a tungsten carbide roll. This roll slowly transfers a mirror image of the profile onto the grinding surface of a wheel. The transfer rate of the profile is between 0.001 and 0.010 inches per minute. Crush grinding is desirable since it provides consistent surface finishes and thin walls at a high production rate. In addition, it generates very sharp fillet radii. However, crush grinding is a complex process since many variables affect the final product. Therefore, the process requires more attention and knowledge beyond basic metal removal practices. While the Kansas City Plant began using these machines in 1995, a formal study regarding crush grinding has not been conducted there. In addition, very little literature is available in the grinding industry regarding this process. As a result, new engineers at the Kansas City Plant must learn the process through trial and error. The purpose of this document is to address this literature deficit while specifically promoting a better understanding of the stem crush grinding process at the Kansas City Plant.

  14. Interdisciplinary group of mammography (IGM). Quality assurance in mammography

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Assurance quality must be a preoccupation of each day in mammography. To be efficient and of low cost it must be discussed between radiologists and physicists; some countries like Federal Republic of Germany, Belgium, United Kingdom, Scandinavia and Netherlands engaged actions to make assurance quality a daily practice

  15. Quality Imaging - Comparison of CR Mammography with Screen-Film Mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin Nieto, J.; Iran Diaz Gongora, J. A.; Arreola, M.; Casian Castellanos, G.; Perdigon Castaneda, G. M.; Franco Enriquez, J. G.

    2006-01-01

    The aim of this work is a quality imaging comparison of CR mammography images printed to film by a laser printer with screen-film mammography. A Giotto and Elscintec dedicated mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in screen-film mammography. Four CR mammography units from two different manufacturers and three dedicated x-ray mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in CR mammography. The tests quality image included an assessment of system resolution, scoring phantom images, Artifacts, mean optical density and density difference (contrast). In this study, screen-film mammography with a quality control program offers a significantly greater level of quality image relative to CR mammography images printed on film

  16. A study on the utilization of stone powder sludge (III)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Kwon; Sohn, Jeong Soo; Kim, Byung Gyu [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    This study was performed to activate the building stone industry by increasing the recycling amounts of waste resources and minimizing the generation of the environmental pollution materials. In order to utilize the waste stone and stone powder sludge generated from the domestic quarry and cutting process of stone plates, the manufacturing technology of the artificial stone plate as a building material was developed. Based on the first and second year results, this third-year study was performed for manufacturing the large-scale artificial stone plate of 500 x 500 x 20 mm. Also for applying these artificial stone plates to the flooring and interior materials in the building industry, the manufacture of the large-scale artificial stone plates with various patterns and colors was carried out by changing the species and the ratio of raw materials, amounts of binder and molding pressure. Artificial stone plate was composed of waste crushed stone, stone powder sludge and binder which was used for binding waste stone and rock powder each other. In order to investigate the physical properties of large-scale artificial stone, the measure of specific gravity, absorption ratio, P-wave velocity, compressive strength, tensile strength, Young`s modulus, and Poisson`s ratio were carried out. As a result of testing physical properties, there was no difference between small-scale artificial stone and large-scale one. At the optimum conditions it was shown that the properties of artificial stones were as follows, 2.32 of specific gravity, 0.33 of water-absorption ratio, 780 kg/cm{sup 2} of compressive strength and 98 kg/cm{sup 2} of tensile strength. Based on the above results, the preliminary economic estimation on the manufacture of the artificial stone plate was carried out. It was shown that the manufacturing cost of the artificial stone plate was 18,000 won/m{sup 2}, which was merely half that of natural stone plate, and the application of these on the building stone industry

  17. Effects of insulin-like growth factor-I and platelet-rich plasma on sciatic nerve crush injury in a rat model.

    Science.gov (United States)

    Emel, Erhan; Ergün, Selma Sönmez; Kotan, Dilcan; Gürsoy, Esra Başar; Parman, Yeşim; Zengin, Asli; Nurten, Asiye

    2011-02-01

    Local administration of insulin-like growth factor-I (IGF-I) has been shown to increase the rate of axon regeneration in crush-injured and freeze-injured rat sciatic nerves. Local administration of platelet-rich plasma (PRP) has been also shown to have a measurable effect on facial nerve regeneration after transection in a rat model. The objective of the study was to compare the effects of locally administered IGF-I and PRP on the parameters of the Sciatic Function Index (SFI), sensory function (SF), axon count, and myelin thickness/axon diameter ratio (G-ratio) in a rat model of crush-injured sciatic nerves. The right sciatic nerve of Wistar albino rats (24 animals) was crushed using a Yasargil-Phynox aneurysm clip for 45 minutes. All animals were randomly divided into 3 groups: Group 1 (control group) was treated with saline, Group 2 was treated with IGF-I, and Group 3 was treated with PRP. Injections were performed using the tissue expander's injection port with a connecting tube directed at the crush-injured site. Functional recovery was assessed with improvement in the SFI. Recovery of sensory function was using the pinch test. Histopathological examination was performed 3 months after the injury. The SFI showed an improved functional recovery in the IGF-I-treated animals (Group 2) compared with the saline-treated animals (Group 1) 30 days after the injury. In IGF-I-treated rats, sensory function returned to the baseline level significantly faster than in saline-treated and PRP-treated rats as shown in values between SF-2 and SF-7. The G-ratios were found to be significantly higher in both experimental groups than in the control group. This study suggests that the application of IGF-I to the crush-injured site may expedite the functional recovery of paralyzed muscle by increasing the rate of axon regeneration.

  18. Sustainable normal and high strength recycled aggregate concretes using crushed tested cylinders as coarse aggregates

    Directory of Open Access Journals (Sweden)

    Bilal S. Hamad

    2017-12-01

    Full Text Available The paper reports on a research program that was designed at the American University of Beirut (AUB to investigate the fresh and hardened mechanical properties of a high performance concrete mix produced with partial or full substitution of crushed natural lime-stone aggregates with recycled aggregates from crushed tested cylinders in batching plants. Choosing crushed cylinders as source of recycling would result in reusing portion of the waste products of the concrete production industry. An extensive concrete batching and testing program was conducted to achieve two optimum normal and high strength concrete mixes. The variables were the nominal concrete strength (28 or 60 MPa and the percentage replacement of natural coarse aggregates with recycled aggregates from crushed tested cylinders (0, 20, 40, 60, 80, or 100%. Normal strength tested cylinders were used as source of the recycled aggregates for the normal strength concrete (NSC mix and high strength tested cylinders were used for the high strength concrete (HSC mix. Tests on the trial batches included plastic state slump and hardened state mechanical properties including cylinder compressive strength, cylinder splitting tensile strength, modulus of elasticity, and standard beams flexural strength. The results indicated no significant effect on the slump and around 10% average reduction in the hardened mechanical properties for both investigated levels of concrete compressive strength.

  19. Migration behavior and sorption mechanisms of radionuclides in sedimentary sand stones

    International Nuclear Information System (INIS)

    Tanaka, Tadao; Kamiyama, Hideo; Sriyotha, K.

    1993-05-01

    The influence of crushed particle size and weathering of sedimentary rock on migration behavior and sorption mechanisms of 60 Co, 85 Sr and 137 Cs has been investigated by using the fresh sand stones (classified into two particle size ranges of 1 ∼ 3 mm and 2 , KCl, NH 2 OH-HCl, K-oxalate and H 2 O 2 solutions were carried out, to elucidate their dominated sorption mechanisms. Distribution coefficient values of the all three radionuclides, Kds, for the sand stone of 1 ∼ 3 mm was smaller than that of 85 Sr, and the same irreversible sorptions as the selective sorption of Co onto manganese oxides and fixation of Cs by the layer silicate for 60 Co and 137 Cs, respectively. Larger sorbability of the weathered sand stone was explained to be related to an increase of amounts of the effective sorption site, such as cation exchangeable site, calcite, smectite and manganese oxides, which was possibly caused from metamorphism induced by weathering the fresh sand stone. (author)

  20. Digital mammography

    International Nuclear Information System (INIS)

    Bick, Ulrich; Diekmann, Felix

    2010-01-01

    This state-of-the-art reference book provides in-depth coverage of all aspects of digital mammography, including detector technology, image processing, computer-aided diagnosis, soft-copy reading, digital workflow, and PACS. Specific advantages and disadvantages of digital mammography in comparison to screen-film mammography are thoroughly discussed. By including authors from both North America and Europe, the book is able to outline variations in the use, acceptance, and quality assurance of digital mammography between the different countries and screening programs. Advanced imaging techniques and future developments such as contrast mammography and digital breast tomosynthesis are also covered in detail. All of the chapters are written by internationally recognized experts and contain numerous high-quality illustrations. This book will be of great interest both to clinicians who already use or are transitioning to digital mammography and to basic scientists working in the field. (orig.)

  1. Fundamental study on the melting process of crushed ice in a heat storage container; Chikunetsu sonai ni takuwaeta saihyo no yukai ni kansuru kisoteki kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Yanadori, M; Kobori, H [Hitachi, Ltd., Tokyo (Japan); Tsubota, Y [Tokyo Electric Power Co. Inc., Tokyo (Japan)

    1998-03-25

    This report deals with heat transfer in the melting process of crushed ice filling in a ice/water heat storage container. Volumetric heat transfer rate and melting end-time are measured when rectangular-type, small-stone-type and particle-type ice in the container are melted by circulation hot water. Melting end-time of small-stone-type ice is the shortest and that of particle-type ice is the latest. Volumetric heat transfer rate of small-stone-type ice and rectangular-type ice is larger than that of particle-type ice. The flow rate of circulation hot water throwing in container through a inlet pipe influences remarkably on heat transfer rate. 4 refs., 10 figs.

  2. Patterns and determinants of mammography screening in Lebanese women

    Directory of Open Access Journals (Sweden)

    Nadia Elias

    2017-03-01

    Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  3. Cultural views, language ability, and mammography use in Chinese American women.

    Science.gov (United States)

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S

    2009-12-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women's ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors' results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population.

  4. Tests with films and film-screens using grid-mammography

    International Nuclear Information System (INIS)

    Wolf, G.; Kallinger, G.

    1982-01-01

    A comparison was made between mammography using grid-technique with a film-screen-system and mammography without grid, and with film-screens and also using industrial films. The image-quality of grid mammography looks like the same than using conventional techniques and industrial films. The problem of soft tissue grid techniques lies in the dose requirements, which was more than using film-screen-techniques without grid. New and improved recording systems, which reduce radiation dose when using the grid technique were analyzed. (orig.) [de

  5. Ultrasonic mammography

    International Nuclear Information System (INIS)

    Hueneke, B.

    1982-01-01

    608 women are examined by means of ultrasonic mammography during the period of 1 year. 432 patients were examined with the compound method with the U.I. Octoson, a water tank scanner, and 176 patients with the real time method with a directly connected linear-array-scanner. The following results were obtained at the end of the examination period: In the ultrasonic and also in the X-ray mammogram tumour diameters can be determined with an error rate of +- 30%. In the diagnosing of carcinomas, a significant dependence of the exactness on the sice of the tumour is found for the combination of the five methods tested (clinical examination, X-ray mammography, ultrasonic mammography, thermography, cytology). Classifying the individual methods with regard to their exactness, X-ray mammography ranks in front of ultrasonic mammography. Mastopathic changes in the breast can be screened by means of ultrasonic mammography. The structure of the changes can be determined more exactly than with an X-ray picture which is due to the possibility of differentiating solid and cystic structures. In diagnosing fibro-adenomas and establishing diagnoses on young women with dense gland bodies, ultrasonic mammography is superior to radiology both in the ability of screening a finding of a fibro-adenoma (US=88%, X-ray=75%) and in the possibility of classifying it as ''more benign than malignant''. (orig./MG) [de

  6. Analysis of mammography on breast fibroadenoma

    International Nuclear Information System (INIS)

    Fu Xiaomin; Han Benyi; Zhao Yae

    2009-01-01

    Objective: To study the imaging characteristics of breast fibroadenoma on mammograms. Methods: Mammography of 70 patients with breast fibroadenoma confirmed by pathology were analyzed retrospectively. All patients took breast X-ray of mediolateral oblique projection and craniocaudal projection before operation. Results: In 70 cases with fibroadenoma, mammography revealed 74 foci (36 left breast, 38 right breast) of 62 cases, and failed to reveal lesions in 8 cases. The shape of the lesions was round or round-like lesion in 60(31%). The border was well-defined in 46 masses, partly well-outlined in 14 and ill-defined in 4. 'Membranoid sign' can be seen in 40 cases. Conclusion: Typical X-ray findings of breast fibroadenoma is very important, mammography is a good method of choice in diagnosis of fibroadenoma. (authors)

  7. 21 CFR 137.195 - Crushed wheat.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Crushed wheat. 137.195 Section 137.195 Food and... Related Products § 137.195 Crushed wheat. Crushed wheat, coarse ground wheat, is the food prepared by so crushing cleaned wheat other than durum wheat and red durum wheat that, when tested by the method...

  8. Screen-film mammography

    International Nuclear Information System (INIS)

    Logan, W.W.; Janus, J.A.

    1987-01-01

    The development of screen-film mammography has resulted in the re-emergence of confidence, rather than fear, in mammography. When screen-film mammography is performed with state-of-the-art dedicated equipment utilizing vigorous breast compression and a ''soft'' x-ray beam for improved contrast, screen-film images are equivalent or superior to those of reduced-dose xeromammography and superior to those of nonscreen film mammography. Technological aids for conversion from xeromammographic or nonscreen film mammographic techniques to screen-film techniques have been described. Screen-film mammography should not be attempted until dedicated equipment has been obtained and the importance of vigorous compression has been understood

  9. Crush Testing at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Feldman, Matthew R.

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

  10. Classic crush and DK crush stenting techniques.

    Science.gov (United States)

    Zhang, Jun-Jie; Chen, Shao-Liang

    2015-01-01

    Clinical data have supported the advantages of the double kissing (DK) crush technique, which consists of stenting the side branch (SB), balloon crush, first kissing, stenting the main vessel (MV) and final kissing balloon inflation, for complex coronary bifurcation lesions compared to other stenting techniques. Careful rewiring from the proximal cell of the MV stent to make sure the wire is in the true lumen of the SB stent is key to acquiring optimal angiographic results. Balloon anchoring from the MV, alternative inflation and each kissing inflation using large enough non-compliant balloons at high pressure, and the proximal optimisation technique are mandatory to improve both angiographic and clinical outcomes. Stratification of a given bifurcation lesion is recommended before decision making.

  11. [Experimental study on establishment of a simple model of rats crush injury-crush syndrome].

    Science.gov (United States)

    Chen, Xi; Liu, Yuehong; Xu, Wei; Qin, Tingwu; Zhao, Luping; Liu, Shuping; Zhang, Yi; Tan, Hong; Zhou, Yu

    2013-01-01

    To establish a repeatable, simple, and effective model of rat crush injury and crush syndrome. A total of 42 female Sprague Dawley rats (2-month-old, (CS) so as to lay a foundation for further study on CS. weighing 160-180 g) were divided randomly into the control group (n=6) and experimental group (n=36). The rats of the experimental group were used to establish the crush injury and CS model in both lower limbs by self-made crush injury mould. The survival rate and hematuria rate were observed after decompression. The biochemical indexes of blood were measured at 2, 4, 8, 12, 24, and 48 hours after decompression. The samples of muscle, kidney, and heart were harvested for morphological observation. There was no treatment in the control group, and the same tests were performed. Seven rats died and 15 rats had hematuria during compression in the experimental group. Swelling of the lower limb and muscle tissue was observed in the survival rats after reperfusion. The liver function test results showed that the levels of alanine transaminase and aspartate aminotransferase in the experimental group were significantly higher than those in the control group (P congestion and swelling, renal tubular epithelial cell degeneration, edema, necrosis, and myoglobin tube type were found in the kidneys; and myocardial structure had no obvious changes. The method of the crush injury and CS model by self-made crush injury mould is a simple and effective procedure and the experimental result is stable. It is a simple method to establish an effective model of rats crush injury and CS.

  12. Thermophysical properties of reconsolidating crushed salt.

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Urquhart, Alexander [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-03-01

    Reconsolidated crushed salt is being considered as a backfilling material placed upon nuclear waste within a salt repository environment. In-depth knowledge of thermal and mechanical properties of the crushed salt as it reconsolidates is critical to thermal/mechanical modeling of the reconsolidation process. An experimental study was completed to quantitatively evaluate the thermal conductivity of reconsolidated crushed salt as a function of porosity and temperature. The crushed salt for this study came from the Waste Isolation Pilot Plant (WIPP). In this work the thermal conductivity of crushed salt with porosity ranging from 1% to 40% was determined from room temperature up to 300°C, using two different experimental methods. Thermal properties (including thermal conductivity, thermal diffusivity and specific heat) of single-crystal salt were determined for the same temperature range. The salt was observed to dewater during heating; weight loss from the dewatering was quantified. The thermal conductivity of reconsolidated crushed salt decreases with increasing porosity; conversely, thermal conductivity increases as the salt consolidates. The thermal conductivity of reconsolidated crushed salt for a given porosity decreases with increasing temperature. A simple mixture theory model is presented to predict and compare to the data developed in this study.

  13. Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography

    International Nuclear Information System (INIS)

    Diekmann, Felix; Bick, Ulrich

    2007-01-01

    Digital mammography is more and more replacing conventional mammography. Initial concerns about an inferior image quality of digital mammography have been largely overcome and recent studies even show digital mammography to be superior in women with dense breasts, while at the same time reducing radiation exposure. Nevertheless, an important limitation of digital mammography remains: namely, the fact that summation may obscure lesions in dense breast tissue. However, digital mammography offers the option of so-called advanced applications, and two of these, contrast-enhanced mammography and tomosynthesis, are promising candidates for improving the detection of breast lesions otherwise obscured by the summation of dense tissue. Two techniques of contrast-enhanced mammography are available: temporal subtraction of images acquired before and after contrast administration and the so-called dual-energy technique, which means that pairs of low/high-energy images acquired after contrast administration are subtracted. Tomosynthesis on the other hand provides three-dimensional information on the breast. The images are acquired with different angulations of the X-ray tube while the object or detector is static. Various reconstruction algorithms can then be applied to the set of typically nine to 28 source images to reconstruct 1-mm slices with a reduced risk of obscuring pathology. Combinations of both advanced applications have only been investigated in individual experimental studies; more advanced software algorithms and CAD systems are still in their infancy and have only undergone preliminary clinical evaluation. (orig.)

  14. Crushed Salt Constitutive Model

    International Nuclear Information System (INIS)

    Callahan, G.D.

    1999-01-01

    The constitutive model used to describe the deformation of crushed salt is presented in this report. Two mechanisms -- dislocation creep and grain boundary diffusional pressure solution -- are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Upon complete consolidation, the crushed-salt model reproduces the Multimechanism Deformation (M-D) model typically used for the Waste Isolation Pilot Plant (WIPP) host geological formation salt. New shear consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on WIPP and southeastern New Mexico salt. Nonlinear least-squares model fitting to the database produced two sets of material parameter values for the model -- one for the shear consolidation tests and one for a combination of the shear and hydrostatic consolidation tests. Using the parameter values determined from the fitted database, the constitutive model is validated against constant strain-rate tests. Shaft seal problems are analyzed to demonstrate model-predicted consolidation of the shaft seal crushed-salt component. Based on the fitting statistics, the ability of the model to predict the test data, and the ability of the model to predict load paths and test data outside of the fitted database, the model appears to capture the creep consolidation behavior of crushed salt reasonably well

  15. Stone stability under non-uniform flow

    NARCIS (Netherlands)

    Hoan, N.T.

    2008-01-01

    Despite the fact that many studies on the stability of stones in bed protections under flowing water have been conducted, our knowledge is still far from advanced and reliable. Issues like how to quantify the hydraulic loads exerted on the stones on a bed and the associated stability of the stones

  16. Mammography and radiation risk; Mammographie und Strahlenrisiko

    Energy Technology Data Exchange (ETDEWEB)

    Jung, H. [Hamburg Univ. (Germany). Inst. fuer Biophysik und Strahlenbiologie

    1998-10-01

    Breast cancer is the most frequent malignant neoplasia among women in Germany. The use of mammography as the most relevant diagnostic procedure has increased rapidly over the last decade. Radiation risks associated with mammography may be estimated from the results of numerous epidemiological studies providing risk coefficients for breast cancer in relation to age at exposure. Various calculations can be performed using the risk coefficients. For instance, a single mammography examination (bilateral, two views of each breast) of a women aged 45 may enhance the risk of developing breast cancer during her lifetime numerically from about 12% of 12.0036%. This increase in risk is lower by a factor of 3,300 as compared to the risk of developing breast cancer in the absence of radiation exposure. At the age of 40 or more, the benefit of mammography exceeds the radiation risk by a factor of about 100. At higher ages this factor increases further. Finally, the dualism of individual risk and collective risk is considered. It is shown that the individual risk of a patient, even after multiple mammography examinations, is vanishingly small. Nevertheless, the basic principle of minimising radiation exposure must be followed to keep the collective risk in the total population as low as reasonably achievable. (orig.) [Deutsch] Das Mammakarzinom ist in Deutschland die haeufigste Krebserkrankung der Frau, und entsprechend oft wird die Mammographie als das derzeit wichtigste Diagnoseverfahren eingesetzt. Zur Beurteilung des mit einer mammographischen Untersuchung verbundenen Strahlenrisikos liegen die Resultate einer groesseren Anzahl strahlenepidemiologischer Studien vor. Diese liefern den Risikokoeffizienten fuer Brustkrebs in Abhaengigkeit vom Lebensalter bei Strahlenexposition und ermoeglichen somit die Berechnung des altersabhaengigen Strahlenrisikos. Beispielsweise wird durch eine einmalige Mammographie-Untersuchung (bilateral, je zwei Aufnahmen in zwei Ebenen) bei einer 45

  17. Mammography - recent technical developments and their clinical potential

    Energy Technology Data Exchange (ETDEWEB)

    Hemdal, Bengt; Mattsson, Soeren [Malmoe Univ. Hospital (Sweden). Dept. of Radiation Physics; Andersson, Ingvar [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Thilander Klang, Anne [Sahlgrenska Univ. Hospital, Goeteborg (Sweden). Dept. of Medical Physics and Biomedical Engineering; Bengtsson, Gert; Jarlman, O. [Lund Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Leitz, Wolfram [Swedish Radiation Protection Authority, Stockholm (Sweden); Bjurstam, Nils [Univ. of North Norway, Troms (Norway). Dept. of Radiology

    2002-05-01

    today. Nevertheless digital mammography will most likely replace screen-film mammography to a large extent, especially in large-scale operations. However, further evaluation of digital and screen-film mammography must be performed regarding image quality and dose as well as diagnostic outcome in terms of sensitivity, specificity and cost-effectiveness. The question is whether the higher investment costs are outweighed by increased sensitivity and specificity, more rational handling and storing, and the possibilities to use new techniques for image production and analysis. The future use of mammography technique will probably be varying, with the availability of different kinds of digital techniques and also the continued use of screen-film, depending on the patient volume and medical as well as financial aspects.

  18. Mammography - recent technical developments and their clinical potential

    International Nuclear Information System (INIS)

    Hemdal, Bengt; Mattsson, Soeren; Bjurstam, Nils

    2002-05-01

    today. Nevertheless digital mammography will most likely replace screen-film mammography to a large extent, especially in large-scale operations. However, further evaluation of digital and screen-film mammography must be performed regarding image quality and dose as well as diagnostic outcome in terms of sensitivity, specificity and cost-effectiveness. The question is whether the higher investment costs are outweighed by increased sensitivity and specificity, more rational handling and storing, and the possibilities to use new techniques for image production and analysis. The future use of mammography technique will probably be varying, with the availability of different kinds of digital techniques and also the continued use of screen-film, depending on the patient volume and medical as well as financial aspects

  19. Determinants of mammography screening behavior in Iranian women: A population-based study

    Directory of Open Access Journals (Sweden)

    Mitra Moodi

    2012-01-01

    Full Text Available Background: Breast cancer remains a substantial health concern in Iran due to delay and late stage at diagnosis and treatment. Despite the potential benefits of mammography screening for early detection of breast cancer, the performance of this screening among Iranian women is low. For planning appropriate intervention, this study was carried out to identify mammography rates and explore determinants of mammography screening behavior in females of Isfahan, Iran. Materials and Methods: In this population-based study, 384 women of 40 years and older were interviewed by telephone. The Farsi version of Champion′s Health Belief Model scale (CHBMS was used to examine factors associated with mammography screening. The obtained data were analyzed by SPSS (version 16.0 using statistical Chi-square, Fisher Exact test, t-test and multiple logistic regression model to identify the importance rate of socio-demographic and Health Belief Model (HBM variables to predict mammography screening behavior. In all of tests, the level of significant was considered a = 0.05. Results: Mean age ΁ SD of women was 52.24 ΁ 8.2 years. Of the 384 participants, 44.3% reported at least one mammogram in their lifetime. Logistic regression analysis indicated that women were more likely to have mammography if they heard/read about breast cancer (OR = 4.17, 95% CI 2.09, 8.34, menopause in lower age (OR = 0.2, 95% CI 0.87, 0.99 and history of breast problem (OR = 0.9, 95% CI 0.12, 0.32. Also, women who perceived more benefits of mammography (OR = 1.84, 95% CI 1.63, 2.09, fewer barriers of mammography (OR = 0.91, 95% CI 0.86, 0.96 and had more motivation for health (OR = 0.94, 95% CI 0.89, 1 were more likely to have mammography. Conclusion: The findings indicated that the rate of mammography screening among women in Isfahan province is low and highlights the need for developing a comprehensive national breast cancer control program, which should be considered as the first

  20. Crushing method for nuclear fuel powder

    International Nuclear Information System (INIS)

    Hasegawa, Shin-ichi; Tsuchiya, Haruo.

    1997-01-01

    A crushing medium is contained in mill pots disposed at the circumferential periphery of a main axis. The diameter of each mill pot is determined such that powdery nuclear fuels containing aggregated powders and ground and mixed powders do not reach criticality. A plurality of mill pots are revolved in the direction of the main axis while each pots rotating on its axis. Powdery nuclear fuels containing aggregated powders are conveyed to a supply portion of the moll pot, and an inert gas is supplied to the supply portion. The powdery nuclear fuels are supplied from the supply portion to the inside of the mill pots, and the powdery nuclear fuels containing aggregated powders are crushed by centrifugal force caused by the rotation and the revolving of the mill pots by means of the crushing medium. UO 2 powder in uranium oxide fuels can be crushed continuously. PuO 2 powder and UO 2 powder in MOX fuels can be crushed and mixed continuously. (I.N.)

  1. Artificial porous stone from of ornamental rock waste adaptable for civil construction and heritage restoration

    International Nuclear Information System (INIS)

    Durán Suárez, J.A.; García Casco, A.

    2017-01-01

    The technique of volumetric reintegration in severely deteriorated stone materials is of major importance for the restoration of architectural heritage. In using mortars for restoration it is important to control aspects such as the colour and textural similarity in relation to the adjacent stone, minor or equal strength and equal or greater porosity/permeability with respect to the original stone. This latter aspect is of particular complexity because the percentage distribution of pore-size ranges should not differ from that of the original stone material. The invention patent (with numbers of publication ES2187245 A1 and B1 16. 06. 2004), owned by the University of Granada, allows the production of excellent porous stones for decorative work in construction and mortar for restoration of stone materials with controlled porosity. Both materials consist of ornamental rock waste, so that a particular recycling purpose is given to this type of material which is difficult to reuse. In this paper we present the manufacturing process of these artificial stones and porous mortars with decorative and restorative purposes, from the controlled mixture of aggregates of ornamental rocks, organic and inorganic binders and generators of porosity. Once the curing and hardening has been done it is worth noting that one of the most important aspects of the product is the generation of a complex connected porous system as a result of the incorporation of crushed expanded polystyrene, which is activated after hardening through the application of organic solvents. [es

  2. Determination of dispersity of crushed granite

    International Nuclear Information System (INIS)

    Liu Dejun; Fan Xianhua; Zhang Yingjie; Yao Jun; Zhou Duo; Wang Yong

    2004-01-01

    The experimental crushed granite column breakthrough curves, using 99 Tc as spike tracer and 3 H as invariant tracer, are analyzed by different linear regression techniques. Dispersity of crushed granite and retardation factor of 99 TcO 4 - on the crushed granite are determined simultaneously by one linear regression technique. Dispersity of crushed granite is also obtained with 3 H as invariant tracer by the other linear regression technique. The dispersities found by spike source and invariant source methods are compared. The experimental results show that the dispersity found by spike source method is close to that found by invariant source method. It indicates that dispersity is only the characteristic of dispersion medium

  3. Determination of dispersity of crushed granite

    International Nuclear Information System (INIS)

    Liu, D.J.; Fan, X.H.

    2005-01-01

    Experimental crushed granite column breakthrough curves, using 99 Tc as spike tracer and 3 H as invariant tracer, were analyzed by different linear regression techniques. Dispersity of crushed granite and the retardation factor of 99 TcO 4 - on the crushed granite were determined simultaneously by one linear regression. Dispersity of crushed granite was also obtained with 3 H as invariant tracer by the other linear regression. The dispersities found by spike source and invariant source methods are compared. Experimental results show that the dispersity found by the spike source method is close to that found by the invariant source method. This indicates that dispersity is only a characteristic of the dispersion medium. (author)

  4. Experience with digital mammography

    Directory of Open Access Journals (Sweden)

    G. P. Korzhenkova

    2011-01-01

    Full Text Available The use of digital techniques in mammography has become a last step for completing the process of digitization in diagnostic imaging. It is assumed that such a spatial decision will be required for digital mammography, as well as for high-resolution intensifying screen-film systems used in conventional mammography and that the digital techniques will be limited by the digitizer pixel size on detecting minor structures, such as microcalcifications. The introduction of digital technologies in mammography involves a tight control over an image and assures its high quality.

  5. Information on mammography-screening - from deception to insight

    International Nuclear Information System (INIS)

    Muehlhauser, I.; Hoeldke, B.

    2002-01-01

    Information about mammography-screening as a basis for informed-decision making has to be evidence-based and presented in an unbiased format. This includes communication of results about effectiveness/lack of effectiveness of screening programmes (breast cancer mortality, total mortality), the quality of mammography as a screening test (sensitivity, specificity, positive and negative predictive values), and possible harm (consequences of false positive and false negative results, overdiagnosis of breast cancer, overtreatment). Outcome data have to be communicated as natural frequencies rather than relative differences. In order to avoid framing of data equal emphasis has to be put on the proportion of persons who are likely to benefit and those who are unlikely to benefit or likely to be harmed. (orig.) [de

  6. Mammography practices for radiation protection in Kenya

    International Nuclear Information System (INIS)

    Shadrack, Anthony K.

    2008-01-01

    All mammography units in the country, totaling fourteen in number at the time, were evaluated on the basis of performance and practice to come up with useful data for summing up the mammography practice in Kenya. The study was carried out by performing hands-on quality control tests on the units using internationally established protocols. Image quality and dose measurement data were generated in all the centers and clearly indicated that the practice of mammography, more so on optimization viewpoint is so much varied. A standard method was used to obtain these data by use of mammography accreditation phantom. Data from actual patients was also collected in three major centers in Nairobi. On the criteria used for evaluating phantom image quality, ten out of fourteen units did satisfy the set criterion. The average glandular dose was 2.79 mGy per cranio caudal (cc) view of the phantom and 3.27 mGy per cc view for the sampled patients. The internationally recommended dose level for such a view is 3.0 mGy. One worrying observation made was that most units failed on one of the easiest test of mammographic unit assembly. Of most concern was the lack of technique charts for the practice detailing the imaging parameters being employed for the procedure. Most centers do not take the servicing of equipment seriously and others merely ignore even the crucial issues of equipment performance like the automatic exposure control and viewing conditions of the reporting areas.The results of this study calls for the setting up of a programme of optimization of radiological protection in mammography using the experience of other countries that have put in place quality assurance programs, setting and adoption of Dose Reference Levels (DRLs) as part of Quality Assurance (QA). This practice needs an effective quality control program which should start with the selection of appropriate equipment for mammography and the use of qualified personnel including the radiologist, radiographer

  7. A numerical approach to model and predict the energy absorption and crush mechanics within a long-fiber composite crush tube

    Science.gov (United States)

    Pickett, Leon, Jr.

    Past research has conclusively shown that long fiber structural composites possess superior specific energy absorption characteristics as compared to steel and aluminum structures. However, destructive physical testing of composites is very costly and time consuming. As a result, numerical solutions are desirable as an alternative to experimental testing. Up until this point, very little numerical work has been successful in predicting the energy absorption of composite crush structures. This research investigates the ability to use commercially available numerical modeling tools to approximate the energy absorption capability of long-fiber composite crush tubes. This study is significant because it provides a preliminary analysis of the suitability of LS-DYNA to numerically characterize the crushing behavior of a dynamic axial impact crushing event. Composite crushing theory suggests that there are several crushing mechanisms occurring during a composite crush event. This research evaluates the capability and suitability of employing, LS-DYNA, to simulate the dynamic crush event of an E-glass/epoxy cylindrical tube. The model employed is the composite "progressive failure model", a much more limited failure model when compared to the experimental failure events which naturally occur. This numerical model employs (1) matrix cracking, (2) compression, and (3) fiber breakage failure modes only. The motivation for the work comes from the need to reduce the significant cost associated with experimental trials. This research chronicles some preliminary efforts to better understand the mechanics essential in pursuit of this goal. The immediate goal is to begin to provide deeper understanding of a composite crush event and ultimately create a viable alternative to destructive testing of composite crush tubes.

  8. Characterization of microcalcification: can digital monitor zooming replace magnification mammography in full-field digital mammography?

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Kwak, Jin Young; Son, Eun Ju; Youk, Ji Hyun; Choi, Seon Hyeong; Oh, Ki Keun; Han, Mooyoung

    2009-01-01

    The aim of this study was to compare the diagnostic accuracy and image quality of microcalcifications in zoomed digital contact mammography with digital magnification mammography. Three radiologists with different levels of experience in mammography reviewed 120 microcalcification clusters in 111 patients with a full-field digital mammography system relying on digital magnification mammogram (MAG) images and zoomed images from contact mammography (ZOOM) using commercially available zooming systems on monitors. Each radiologist estimated the probability of malignancy and rated the image quality and confidence rate. Performance was evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and receiver operating characteristic (ROC) analysis. All three radiologists rated MAG images higher than ZOOM images for sensitivity with statistical significance (average value, 92% vs. 87%, P<0.05) and performance by ROC analysis improved with MAG imaging. The confidence rate for diagnosis decision and the assessment of lesion characteristics were also better in MAG images than in ZOOM images with statistical significance (P<0.0001). Digital magnification mammography can enhance diagnostic performance when characterizing microcalcifications. Images zoomed from digital contact mammography cannot serve as an alternative to direct magnification digital mammography. (orig.)

  9. Characterizing large strain crush response of redwood

    International Nuclear Information System (INIS)

    Cramer, S.M.; Hermanson, J.C.

    1996-12-01

    Containers for the transportation of hazardous and radioactive materials incorporate redwood in impact limiters. Redwood is an excellent energy absorber, but only the most rudimentary information exists on its crush properties. The objectives of the study were to fill the information gap by collecting triaxial load-deformation data for redwood; to use these data to characterize redwood crush, assess current wood failure theories, provide developments toward a complete stress-strain theory for redwood; and to review the literature on strain-rate effects on redwood crush performance. The load-deformation responses of redwood at temperature conditions corresponding to ambient (70 degrees F), 150 degrees F, and -20 degrees F conditions were measured in approximately 100 confined compression tests for crush levels leading to material densification. Data analysis provided a more complete description of redwood crush performance and a basis for assessing proposed general orthotropic stress-strain relationships for redwood. A review of existing literature indicated that strain-rate effects cause at most a 20 percent increase in crush stress parallel to grain

  10. Practical digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Beverly E. [Washington Univ., Seattle, WA (United States)]|[Virginia Mason Medical Center, VA (United States)

    2008-07-01

    This book is meant for the radiologist who is facing the challenge of organizing a digital mammographic imaging center. This text is meant to be a practical book that provides information about digital mammographic physics and equipment which will allow one to intelligently compare technologies and systems. Some of the major challenges include: large expense; rapidly changing technology, and inconsistent connectivity; and finally, need for strong information technology support. The initial conversion cost to digital mammographic imaging is relatively expensive due to the cost of digital mammography hardware, software, and storage. Virtually all other imaging modalities are being converted to purely digital storage and transfer, and the digital trend in mammography is inevitable. Technical advantages of digital mammography are described. However, the improved flexibility in image display and transfer are some of its strongest features. In conclusion, although there are increasing imaging modalities that may be used to evaluate breast disease, mammography will continue to play a key role in detecting breast cancer. To be an effective imager, the radiologist should become familiar with digital mammography and understand its role within the increasing complex structure of breast imaging techniques.

  11. Practical digital mammography

    International Nuclear Information System (INIS)

    Hashimoto, Beverly E.

    2008-01-01

    This book is meant for the radiologist who is facing the challenge of organizing a digital mammographic imaging center. This text is meant to be a practical book that provides information about digital mammographic physics and equipment which will allow one to intelligently compare technologies and systems. Some of the major challenges include: large expense; rapidly changing technology, and inconsistent connectivity; and finally, need for strong information technology support. The initial conversion cost to digital mammographic imaging is relatively expensive due to the cost of digital mammography hardware, software, and storage. Virtually all other imaging modalities are being converted to purely digital storage and transfer, and the digital trend in mammography is inevitable. Technical advantages of digital mammography are described. However, the improved flexibility in image display and transfer are some of its strongest features. In conclusion, although there are increasing imaging modalities that may be used to evaluate breast disease, mammography will continue to play a key role in detecting breast cancer. To be an effective imager, the radiologist should become familiar with digital mammography and understand its role within the increasing complex structure of breast imaging techniques

  12. Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis.

    Science.gov (United States)

    McDonald, Elizabeth S; McCarthy, Anne Marie; Akhtar, Amana L; Synnestvedt, Marie B; Schnall, Mitchell; Conant, Emily F

    2015-11-01

    Baseline mammography studies have significantly higher recall rates than mammography studies with available comparison examinations. Digital breast tomosynthesis reduces recalls when compared with digital mammographic screening alone, but many sites operate in a hybrid environment. To maximize the effect of screening digital breast tomosynthesis with limited resources, choosing which patient populations will benefit most is critical. This study evaluates digital breast tomosynthesis in the baseline screening population. Outcomes were compared for 10,728 women who underwent digital mammography screening, including 1204 (11.2%) baseline studies, and 15,571 women who underwent digital breast tomosynthesis screening, including 1859 (11.9%) baseline studies. Recall rates, cancer detection rates, and positive predictive values were calculated. Logistic regression estimated the odds ratios of recall for digital mammography versus digital breast tomosynthesis for patients undergoing baseline screening and previously screened patients, adjusted for age, race, and breast density. In the baseline subgroup, recall rates for digital mammography and digital breast tomosynthesis screening were 20.5% and 16.0%, respectively (p = 0.002); digital breast tomosynthesis screening in the baseline subgroup resulted in a 22% reduction in recall compared with digital mammography, or 45 fewer patients recalled per 1000 patients screened. Digital breast tomosynthesis screening in the previously screened patients resulted in recall reduction of 14.3% (p tomosynthesis than from digital mammography alone.

  13. Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening.

    Science.gov (United States)

    Haas, Brian M; Kalra, Vivek; Geisel, Jaime; Raghu, Madhavi; Durand, Melissa; Philpotts, Liane E

    2013-12-01

    To compare screening recall rates and cancer detection rates of tomosynthesis plus conventional digital mammography to those of conventional digital mammography alone. All patients presenting for screening mammography between October 1, 2011, and September 30, 2012, at four clinical sites were reviewed in this HIPAA-compliant retrospective study, for which the institutional review board granted approval and waived the requirement for informed consent. Patients at sites with digital tomosynthesis were offered screening with digital mammography plus tomosynthesis. Patients at sites without tomosynthesis underwent conventional digital mammography. Recall rates were calculated and stratified according to breast density and patient age. Cancer detection rates were calculated and stratified according to the presence of a risk factor for breast cancer. The Fisher exact test was used to compare the two groups. Multivariate logistic regression was used to assess the effect of screening method, breast density, patient age, and cancer risk on the odds of recall from screening. A total of 13 158 patients presented for screening mammography; 6100 received tomosynthesis. The overall recall rate was 8.4% for patients in the tomosynthesis group and 12.0% for those in the conventional mammography group (P tomosynthesis reduced recall rates for all breast density and patient age groups, with significant differences (P tomosynthesis versus 5.2 per 1000 in patients receiving conventional mammography alone (P = .70). Patients undergoing tomosynthesis plus digital mammography had significantly lower screening recall rates. The greatest reductions were for those younger than 50 years and those with dense breasts. A nonsignificant 9.5% increase in cancer detection was observed in the tomosynthesis group. © RSNA, 2013.

  14. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    Science.gov (United States)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  15. Promoting mammography screening among Chinese American women using a message-framing intervention.

    Science.gov (United States)

    Sun, Yiyuan; Sarma, Elizabeth A; Moyer, Anne; Messina, Catherine R

    2015-07-01

    This study examined the role of women's perceptions about the relative pros versus cons (decisional balance) of mammography in moderating Chinese American women's responses to gain- and loss-framed messages that promote mammography. One hundred and forty-three Chinese American women who were currently nonadherent to guidelines for receiving annual screening mammograms were randomly assigned to read either a gain- or loss-framed culturally appropriate print brochure about mammography screening. Mammography screening was self-reported at a 2-month follow-up. Although there was not a main effect for message frame, the hypothesized interaction between message frame and decisional balance was significant, indicating that women who received a framed message that matched their decisional balance were significantly more likely to have obtained a mammogram by the follow-up than women who received a mismatched message. Results suggest that decisional balance, and more generally, perceptions about mammography, may be an important moderator of framing effects for mammography among Chinese American women. The match between message frame and decisional balance should be considered when attempting to encourage Chinese American women to receive mammography screening, as a match between the two may be most persuasive. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Investigations of excavated clay-stone as backfill/seal material

    International Nuclear Information System (INIS)

    Zhang, Chun-Liang

    2012-01-01

    Document available in extended abstract form only. Crushed clay-stone produced by excavation activities of repository drifts has been investigated as backfill/seal material at the GRS laboratory. The raw aggregate with coarse grains is considered to be used for backfilling the repository openings and, in mixture with bentonite, for sealing the boreholes, drifts and shafts. The GRS research programme focused on characterizing the thermo-hydro-mechanical properties of the excavated Callovo-Oxfordian clay-stone (COX) and the clay-stone-bentonite mixtures, including mechanical compaction, gas and water permeability as function of porosity, water retention and saturation, swelling capacity, and thermal properties of the materials. The most important results are presented in this paper. Figure 1 shows the compaction and permeability behaviour of the excavated clay-stone with grains up to a size of 32 mm. The results were obtained on large samples of 280 mm diameter and 680 mm height under quasi-hydrostatic compression. The porosity and permeability decrease with increasing load. The porosity-mean stress relation is non-linear and may be expressed by an exponential function. The backfill becomes stiffer at low porosities and can sustain certain deviatoric loads. At porosity of ∼21 %, the strength is characterized by an inherent cohesion of 3.7 MPa and an internal friction angle of 12 deg.. Additionally, the compaction is also dependent on time or loading rate, water content, and temperature. The compaction of the porous backfill material leads to a reduction in permeability. The measured gas permeability decreases much faster at low porosities below ∼25 %. The gas permeability at porosity of ∼20 % becomes as low as that of 10 -20 - 10 -21 m 2 for the intact clay rock. This is probably due to disconnection of the pore network during the compaction. As sealing material, powdered COX clay-stone was mixed with MX80 bentonite powder in different ratios and compacted to

  17. Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.

    Science.gov (United States)

    Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru

    2015-01-01

    A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.

  18. Influence of age and menstrual cycle on mammography and MR imaging of the breast; Einfluss von Alter und Menstruationszyklus auf Mammographie und MR-Mammographie

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Schimpfle, M.; Ohmenhaeuser, K.; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik

    1997-09-01

    Age and menstrual cycle have an important influence on the breast. This well-known fact is experienced in the daily routine of gynecologists and radiologists. The number of publications addressing the effect of these influences on imaging, however, is surprisingly low. The aim of this work is to describe the influences of age and menstrual cycle on the breast and to address their clinical relevance for mammography and MR mammography. Therefore, own data are presented concerning the age and menstrual cycle influences on breast parenchyma in dynamic MR mammography. Literature data are used to correlate mammography and MR imaging findings with these influences. The changes of the breast due to age and menstrual cycle have important direct implications on performing and reading conventional mammography and MR mammography. The knowledge of these changes is also helpful in the interpretation of findings when comparing different methods. Finally, the data gained by using imaging methods enable important basic insights into physiology and physiopathology of the breast in vivo. (orig.) [Deutsch] Alter und Menstruationszyklus stellen wichtige Einflussfaktoren auf die Mamma dar. Diese Tatsache ist klinisch lange bekannt und im Alltag des Gynaekologen wie Radiologen staendig praesent. Dagegen ist die Anzahl der Publikationen zu den Auswirkungen dieser Einfluesse auf die Bildgebung erstaunlich niedrig. Ziel dieser Arbeit ist es, die alters- und zyklusabhaengigen Veraenderungen der Mamma und deren klinische Relevanz fuer die Mammographie und MR-Mammographie darzustellen. Zu diesem Zweck werden aus einer eigenen Studie Daten der dynamischen MR-Tomographie zum Alters- und Zykluseinfluss auf das Mammaparenchym praesentiert. Darueber hinaus werden diese Einflussfaktoren mit mammographischen und MR-tomographischen Daten aus der Literatur korreliert. Dabei zeigt sich, dass sich aus den alters- und menstruationszyklusbedingten Veraenderungen der Brust wichtige unmittelbare

  19. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Michell, M.J.; Iqbal, A.; Wasan, R.K.; Evans, D.R.; Peacock, C.; Lawinski, C.P.; Douiri, A.; Wilson, R.; Whelehan, P.

    2012-01-01

    Aim: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. Materials and methods: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. Results: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286 (37.68%) as benign, and 269 (35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBT combined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. Conclusion: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities.

  20. Effect of Tamsulosin on Stone Passage for Ureteral Stones: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Wang, Ralph C; Smith-Bindman, Rebecca; Whitaker, Evans; Neilson, Jersey; Allen, Isabel Elaine; Stoller, Marshall L; Fahimi, Jahan

    2017-03-01

    Tamsulosin is recommended for patients receiving a diagnosis of a ureteral stone less than 10 mm who do not require immediate urologic intervention. Because of conflicting results from recent meta-analyses and large randomized controlled trials, the efficacy of tamsulosin is unclear. We perform a systematic review and meta-analysis to investigate the effect of tamsulosin on stone passage in patients receiving a diagnosis of ureteral stone. MEDLINE, EMBASE, and CENTRAL databases were searched without language restriction through November 2015 for studies assessing the efficacy of tamsulosin and using a double-blind, randomized, controlled trial design. Meta-analysis was conducted with a random-effects model and subgroup analyses were conducted to determine sources of heterogeneity. Eight randomized controlled trials (N=1,384) contained sufficient information for inclusion. The pooled risk of stone passage in the tamsulosin arm was 85% versus 66% in the placebo arm, but substantial heterogeneity existed across trials (I 2 =80.2%; Ptamsulosin (risk difference=22%; 95% confidence interval 12% to 33%; number needed to treat=5). The meta-analysis of the small stone subgroup (Tamsulosin significantly improves stone passage in patients with larger stones, whereas the effect of tamsulosin is diminished in those with smaller stones, who are likely to pass their stone regardless of treatment. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  1. The relationship of social support concept and repeat mammography among Iranian women.

    Science.gov (United States)

    Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy

    2015-10-24

    Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.

  2. Crushing of ship bows in head-on collision

    DEFF Research Database (Denmark)

    Ocakli, H.; Zhang, S.; Pedersen, Preben Terndrup

    2004-01-01

    Semi-analytical methods for analysis of plate crushing and ship bow damage in head-on collisions are developed in this paper. Existing experimental and theoretical studies for crushing analysis of plated structures are summarized and compared. Simple formulae for determining the crushing force....... The approach developed can be used easily to determine the crushing resistance and damage extent of the ship bow when ship length and collision speed are known. The method can be used in probabilistic analysis of damage extents in ship collisions where a large number of calculations are generally required....

  3. Occasional, obligatory, and habitual stone tool use in hominin evolution.

    Science.gov (United States)

    Shea, John J

    2017-09-01

    Archeologists have long assumed that earlier hominins were obligatory stone tool users. This assumption is deeply embedded in traditional ways of describing the lithic record. This paper argues that lithic evidence dating before 1.7 Ma reflects occasional stone tool use, much like that practiced by nonhuman primates except that it involved flaked-stone cutting tools. Evidence younger than 0.3 Ma is more congruent with obligatory stone tool use, like that among recent humans. The onset of habitual stone tool use at about 1.7 Ma appears correlated with increased hominin logistical mobility (carrying things). The onset of obligatory stone tool use after 0.3 Ma may be linked to the evolution of spoken language. Viewing the lithic evidence dating between 0.3-1.7 Ma as habitual stone tool use explains previously inexplicable aspects of the Early-Middle Pleistocene lithic record. © 2017 Wiley Periodicals, Inc.

  4. Study of radon exhalation rates using solid state nuclear track detectors in stone mining area of Aravali range in Pali region, district Faridabad

    International Nuclear Information System (INIS)

    Raj Kumari; Yadav, A.S.; Kant, Krishan; Garg, Maneesha

    2013-01-01

    It is well established that indoor radon-thoron and daughters are the largest contributor to total radiation dose received by populations. They account for more than 50% of the total dose and the radiation exposure beyond permissible levels can lead to deleterious effects on health. This fact necessitates extensive studies of natural radioactivity levels in the stone mining area of Aravali range in Faridabad. The stone mining area of Aravali Range in Pali, District Faridabad bears significant geological features. Radon exhalation from ground plays an important role in enhanced indoor radon levels and can pose grave health hazards to the workers and the residents. Exhalation rates (mass and surface) from stone samples of the area have been studied using LR-115, Type II nuclear track detectors. The mass and surface exhalation rates from crushed stone samples, also called stone dust varied in the range 3.41-9.11 mBq kg -1 h - 1 and 75.9-202.7 mBq m -2 h -1 , respectively. The study has revealed substantial presence of radionuclides in the samples collected from the mining area. (author)

  5. Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program.

    Science.gov (United States)

    Skaane, Per; Bandos, Andriy I; Gullien, Randi; Eben, Ellen B; Ekseth, Ulrika; Haakenaasen, Unni; Izadi, Mina; Jebsen, Ingvild N; Jahr, Gunnar; Krager, Mona; Niklason, Loren T; Hofvind, Solveig; Gur, David

    2013-04-01

    To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial. A prospective, reader- and modality-balanced screening study of participants undergoing combined mammography plus tomosynthesis, the results of which were read independently by four different radiologists, is under way. The study was approved by a regional ethics committee, and all participants provided written informed consent. The authors performed a preplanned interim analysis of results from 12,631 examinations interpreted by using mammography alone and mammography plus tomosynthesis from November 22, 2010, to December 31, 2011. Analyses were based on marginal log-linear models for binary data, accounting for correlated interpretations and adjusting for reader-specific performance levels by using a two-sided significance level of .0294. Detection rates, including those for invasive and in situ cancers, were 6.1 per 1000 examinations for mammography alone and 8.0 per 1000 examinations for mammography plus tomosynthesis (27% increase, adjusted for reader; P = .001). False-positive rates before arbitration were 61.1 per 1000 examinations with mammography alone and 53.1 per 1000 examinations with mammography plus tomosynthesis (15% decrease, adjusted for reader; P tomosynthesis; P = .72). Twenty-five additional invasive cancers were detected with mammography plus tomosynthesis (40% increase, adjusted for reader; P tomosynthesis (P tomosynthesis in a screening environment resulted in a significantly higher cancer detection rate and enabled the detection of more invasive cancers. Clinical trial registration no. NCT01248546. RSNA, 2013

  6. Study comparing the double kissing (DK) crush with classical crush for the treatment of coronary bifurcation lesions: the DKCRUSH-1 Bifurcation Study with drug-eluting stents.

    Science.gov (United States)

    Chen, S L; Zhang, J J; Ye, F; Chen, Y D; Patel, T; Kawajiri, K; Lee, M; Kwan, T W; Mintz, G; Tan, H C

    2008-06-01

    Classical crush has a lower rate of final kissing balloon inflation (FKBI) immediately after percutaneous coronary intervention (PCI). The double kissing (DK) crush technique has the potential to increase the FKBI rate, and no prospective studies on the comparison of classical with DK crush techniques have been reported. Three hundred and eleven patients with true bifurcation lesions were randomly divided into classical (n = 156) and DK crush (n = 155) groups. Clinical and angiographic details at follow-up at 8 months were indexed. The primary end point was major adverse cardiac events (MACE) including myocardial infarction, cardiac death and target lesion revascularization (TLR) at 8 months. FKBI was 76% in the classical crush group and 100% in the DK group (P DK crush group. Cumulative 8 month MACE was 24.4% in the classical crush group and 11.4% in the DK crush group (P = 0.02). The TLR-free survival rate was 75.4% in the classical crush group and 89.5% in the DK crush group (P = 0.002). DK crush technique has the potential of increasing FKBI rate and reducing stent thrombosis, with a further reduction of TLR and cumulative MACE rate at 8 months.

  7. The U.S. Online News Coverage of Mammography Based on a Google News Search.

    Science.gov (United States)

    Young Lin, Leng Leng; Rosenkrantz, Andrew B

    2017-12-01

    To characterize online news coverage relating to mammography, including articles' stance toward screening mammography. Google News was used to search U.S. news sites over a 9-year period (2006-2015) based on the search terms "mammography" and "mammogram." The top 100 search results were recorded. Identified articles were manually reviewed. The top 100 news articles were from the following sources: local news outlet (50%), national news outlet (24%), nonimaging medical source (13%), entertainment or culture news outlet (6%), business news outlet (4%), peer-reviewed journal (1%), and radiology news outlet (1%). Most common major themes were the screening mammography controversy (29%), description of a new breast imaging technology (23%), dense breasts (11%), and promotion of a public screening initiative (11%). For the most recent year, article stance toward screening mammography was 59%, favorable; 16%, unfavorable; and 25%, neutral. After 2010, there was an abrupt shift in articles' stances from neutral to both favorable and unfavorable. A wide range of online news sources addressed a range of issues related to mammography. National, rather than local, news sites were more likely to focus on the screening controversy and more likely to take an unfavorable view. The controversial United States Preventive Services Task Force guidelines may have influenced articles to take a stance on screening mammography. As such online news may impact public perception of the topic and thus potentially impact guideline adherence, radiologists are encouraged to maintain awareness of this online coverage and to support the online dissemination of reliable and accurate information. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Patterns and determinants of mammography screening in Lebanese women.

    Science.gov (United States)

    Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M

    2017-03-01

    The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  9. Diffusion in the pore water of compacted crushed salt

    Energy Technology Data Exchange (ETDEWEB)

    Fluegge, Judith; Herr, Sebastian; Lauke, Thomas; Meleshyn, Artur; Miehe, Ruediger; Ruebel, Andre

    2016-07-15

    Diffusion of dissolved radionuclides in the pore water of compacted crushed salt in the long-term is the most relevant process for the release of radionuclides from a dedicated repository for high-level waste in a salt formation as has been shown in latest safety assessments and research projects /BUH 16/. So far, diffusion coefficients for free water have been applied for the diffusion in pore water in models for long-term safety assessments. This conservative assumption was used, because data on the diffusion coefficient of dissolved substances in crushed salt have been missing. Furthermore, the diffusion coefficient in the pore water was assumed to be constant and independent from the degree of compaction of the crushed salt. The work presented in this report was intended to contribute to fill this gap of knowledge about how the diffusion of radionuclides takes place in the compacted backfill of a repository in salt. For the first time, the pore diffusion coefficient as well as its dependence on the porosity of the crushed salt was determined experimentally by means of through-diffusion experiments using caesium as tracer. The results achieved in this project suggest that the diffusion in compacted crushed salt is not fully comparable to that in a homogeneous, temporally stable porous medium like sand or clay. The results obtained from four diffusion experiments show a remarkably different behaviour and all yield unique concentration versus time plots which includes highly temporal variable tracer fluxes with even full interruptions of the flux for longer periods of time. This effect cannot be explained by assuming a tracer transport by diffusion in a temporarily invariant pore space and / or under temporally invariant experimental conditions. From our point of view, a restructuring of the pore space seems to lead to closed areas of pore water in the sample which may open up again after some time, leading to a variable pore space and hence variable diffusive

  10. Quality assurance programme at Slovak mammography departments

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.

    2004-01-01

    A co-ordinated research program (CRP) for optimisation of image quality in mammography in some Eastern European countries has been initiated by IAEA between 1999 and 2001 and the Slovak Republic took part in this program. The aim of this program was to implement the European QA/QC protocol in a sample of mammography departments and to achieve improvement of the image quality and patient dose reduction. On the national level 28 mammography units were chosen in accordance with equipment performance for quality control programme at this departments, for the first part of the mammography audit in the years 2002-2004. Realisation of CRP project contains: 1) Collection and evaluation of clinical images in agreement with EC criteria; 2) Evaluation of the image quality using mammography test phantom; 3) Measurements of the ESD at patients using TLD; 4) Intercomparison of TLD system calibration with IAEA laboratory; 5) Film reject analysis; 6) Implementation of QC program to the mammography units. The measurements of ESD on patients were performed with TLD (LiF 700 Harshaw). In the 6 month period were collected the results of measurements of: 1) object thickness compensation (measured weekly); 2) long time reproducibility (measured daily); 3) phantom image quality on the standard RMI 156 phantom (measured weekly); 4) ESD on phantom with TLD (once during the audit). Automatic Exposure Control compensation for the object thickness variation was measured by exposing different PMMA plates of thickness ranging from 20 to 60 mm, using the clinical settings. The long term reproducibility has been assessed from the measurements of the optical density and mAs product resulted from the exposure on the PMMA plates. In order to estimate the quality of the images the RMI 156 mammography accreditation phantom was chosen. The accreditation phantom contains test objects which simulate small structures seen in the breast (microcalcifications, fibrils, and tumor like masses). Results of

  11. Mammography image compression using Wavelet

    International Nuclear Information System (INIS)

    Azuhar Ripin; Md Saion Salikin; Wan Hazlinda Ismail; Asmaliza Hashim; Norriza Md Isa

    2004-01-01

    Image compression plays an important role in many applications like medical imaging, televideo conferencing, remote sensing, document and facsimile transmission, which depend on the efficient manipulation, storage, and transmission of binary, gray scale, or color images. In Medical imaging application such Picture Archiving and Communication System (PACs), the image size or image stream size is too large and requires a large amount of storage space or high bandwidth for communication. Image compression techniques are divided into two categories namely lossy and lossless data compression. Wavelet method used in this project is a lossless compression method. In this method, the exact original mammography image data can be recovered. In this project, mammography images are digitized by using Vider Sierra Plus digitizer. The digitized images are compressed by using this wavelet image compression technique. Interactive Data Language (IDLs) numerical and visualization software is used to perform all of the calculations, to generate and display all of the compressed images. Results of this project are presented in this paper. (Author)

  12. Beyond the mammography debate: a moderate perspective.

    Science.gov (United States)

    Kaniklidis, C

    2015-06-01

    After some decades of contention, one can almost despair and conclude that (paraphrasing) "the mammography debate you will have with you always." Against that sentiment, in this review I argue, after reflecting on some of the major themes of this long-standing debate, that we must begin to move beyond the narrow borders of claim and counterclaim to seek consensus on what the balance of methodologically sound and critically appraised evidence demonstrates, and also to find overlooked underlying convergences; after acknowledging the reality of some residual and non-trivial harms from mammography, to promote effective strategies for harm mitigation; and to encourage deployment of new screening modalities that will render many of the issues and concerns in the debate obsolete. To these ends, I provide a sketch of what this looking forward and beyond the current debate might look like, leveraging advantages from abbreviated breast magnetic resonance imaging technologies (such as the ultrafast and twist protocols) and from digital breast tomosynthesis-also known as three-dimensional mammography. I also locate the debate within the broader context of mammography in the real world as it plays out not for the disputants, but for the stakeholders themselves: the screening-eligible patients and the physicians in the front lines who are charged with enabling both the acts of screening and the facts of screening at their maximally objective and patient-accessible levels to facilitate informed decisions.

  13. Patients Mammographic Dose Survey in a Sample of Slovak Mammography Departments

    International Nuclear Information System (INIS)

    Nikodemova, D.; Horvathova, M.; Gbelcova, L.

    2008-01-01

    Breast cancer is the most frequent cancer and the most frequent cause of cancer induced deaths in Europe. Demographic trends indicate a continuing increase in this substantial public health problem. Systematic early detection, effective diagnostic pathways and high quality services have the ability for lowering the breast cancer mortality rates and for reducing the burden of this disease in the population The widespread use of mammography for early breast cancer detection is highly accepted all over the world. For achievement of a successful national mammography programme in Slovakia, a national QA/QC mammography system was introduced. Coming from alarming values of increase of malignant neoplasm of breast in Slovakia a national mammography audit has been initiated, performed in three runs and working in three phases: assessment of existing status of practice and equipment performance, as well as education and training of radiologists and radiographers of 42 mammography departments; implementation of technical quality programme and patient dose evaluation; clinical image evaluation. Preventive mammography in spite of being a reasonable examination, which represents health benefit for patient, exceed also the health risk. In 1991-1996 mammographic examination created 1.3% from all medical radiodiagnostic expositions made in Slovakia. In 2005 there were realized 241 208 mammographic examinations, 140 798 of them were noticed like preventive examinations. In 2006 the number of all mammographic examinations in Slovakia increased to 271 755 and of them 156 199 were preventive mammographic examinations. In our presentation we tried to establish the average absorbed glandular doses of patients undergoing mammography examinations in 10 selected departments and to compare the obtained results with European diagnostic reference values. The obtained values were used for the proposal of a new national diagnostic reference value for mammography examinations

  14. Mammography-oncogenecity at low doses

    International Nuclear Information System (INIS)

    Heyes, G J; Mill, A J; Charles, M W

    2009-01-01

    Controversy exists regarding the biological effectiveness of low energy x-rays used for mammography breast screening. Recent radiobiology studies have provided compelling evidence that these low energy x-rays may be 4.42 ± 2.02 times more effective in causing mutational damage than higher energy x-rays. These data include a study involving in vitro irradiation of a human cell line using a mammography x-ray source and a high energy source which matches the spectrum of radiation observed in survivors from the Hiroshima atomic bomb. Current radiation risk estimates rely heavily on data from the atomic bomb survivors, and a direct comparison between the diagnostic energies used in the UK breast screening programme and those used for risk estimates can now be made. Evidence highlighting the increase in relative biological effectiveness (RBE) of mammography x-rays to a range of x-ray energies implies that the risks of radiation-induced breast cancers for mammography x-rays are potentially underestimated by a factor of four. A pooled analysis of three measurements gives a maximal RBE (for malignant transformation of human cells in vitro) of 4.02 ± 0.72 for 29 kVp (peak accelerating voltage) x-rays compared to high energy electrons and higher energy x-rays. For the majority of women in the UK NHS breast screening programme, it is shown that the benefit safely exceeds the risk of possible cancer induction even when this higher biological effectiveness factor is applied. The risk/benefit analysis, however, implies the need for caution for women screened under the age of 50, and particularly for those with a family history (and therefore a likely genetic susceptibility) of breast cancer. In vitro radiobiological data are generally acquired at high doses, and there are different extrapolation mechanisms to the low doses seen clinically. Recent low dose in vitro data have indicated a potential suppressive effect at very low dose rates and doses. Whilst mammography is a low

  15. Gypsum accumulation on carbonate stone

    Science.gov (United States)

    McGee, E.S.; Mossotti, V.G.

    1992-01-01

    The accumulation of gypsum on carbonate stone has been investigated through exposure of fresh samples of limestone and marble at monitored sites, through examination of alteration crusts from old buildings and through laboratory experiments. Several factors contribute to gypsum accumulation on carbonate stone. Marble or limestone that is sheltered from direct washing by rain in an urban environment with elevated pollution levels is likely to accumulate a gypsum crust. Crust development may be enhanced if the stone is porous or has an irregular surface area. Gypsum crusts are a surficial alteration feature; gypsum crystals form at the pore opening-air interface, where evaporation is greatest.

  16. Studies Comparing Screen-Film Mammography and Full-Field Digital Mammography in Breast Cancer Screening: Updated Review

    International Nuclear Information System (INIS)

    Skaane, P.

    2009-01-01

    Full-field digital mammography (FFDM) has several potential benefits as compared with screen-film mammography (SFM) in mammography screening. Digital technology also opens for implementation of advanced applications, including computer-aided detection (CAD) and tomosynthesis. Phantom studies and experimental clinical studies have shown that FFDM is equal or slightly superior to SFM for detection and characterization of mammographic abnormalities. Despite obvious advantages, the conversion to digital mammography has been slower than anticipated, and not only due to higher costs. Until very recently, some countries did not even permit the use of digital mammography in breast cancer screening. The reason for this reluctant attitude was concern about lower spatial resolution and about using soft-copy reading. Furthermore, there was a lack of data supporting improved diagnostic accuracy using FFDM in a screening setting, since two pioneer trials both showed nonsignificantly lower cancer detection rate at FFDM. The 10 studies comparing FFDM and SFM in mammography screening published so far have shown divergent and rather conflicting results. Nevertheless, there is a rapid conversion to digital mammography in breast cancer screening in many western countries. The aim of this article is to give an updated review of these studies, discuss the conflicting findings, and draw some conclusions from the results

  17. The mammography screening employee inreach program.

    Science.gov (United States)

    Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria

    2007-02-01

    To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.

  18. Effectiveness of a Mobile Mammography Program.

    Science.gov (United States)

    Stanley, Elizabeth; Lewis, Madelene C; Irshad, Abid; Ackerman, Susan; Collins, Heather; Pavic, Dag; Leddy, Rebecca J

    2017-12-01

    cancer center (cancer center = 8.09%, mobile unit = 4.47%). There was a significant association between location and geographic area (χ 2 = 33.33, p mobile unit = 70.62%). There was a significant association between location and adherence to screening guidelines (χ 2 = 179.60, p mobile unit = 34.47%). Finally, there was a significant association between location and recall rate (χ 2 = 4.06, p mobile van (15.98%). Of those patients with BI-RADS 0, there was a significant association between location and adherence to follow-up (χ 2 = 22.75, p mobile unit less likely to return for additional imaging (cancer center = 2.65%, mobile unit = 17.03%). Significant differences were found among patients visiting the cancer center versus the mobile mammography van. The cancer center's population is older and more adherent to guidelines, whereas the mobile mammography population exhibited greater racial and marital diversity, higher recall rate, and lack of adherence to follow-up recommendations. By identifying these characteristics, we can develop programs and materials that meet these populations' needs and behaviors, ultimately increasing mammography screening and follow-up rates among underserved populations.

  19. Accelerated weathering of limestone for CO2 mitigation opportunities for the stone and cement industries

    Science.gov (United States)

    Langer, W.H.; Juan, C.A.S.; Rau, G.H.; Caldeira, K.

    2009-01-01

    Large amounts of limestone fines coproduced during the processing of crushed limestone may be useful in the sequestration of carbon dioxide (CO 2). Accelerated weathering of limestone (AWL) is proposed as a low-tech method to capture and sequester CO2 from fossil fuel-fired power plants and other point-sources such as cement manufacturing. AWL reactants are readily available, inexpensive, and environmentally benign. Waste CO 2 is hydrated with water to produce carbonic acid, which then reacts with and is neutralized by limestone fines, thus converting CO2 gas to dissolved calcium bicarbonate. AWL waste products can be disposed of in the ocean. Feasibility requires access to an inexpensive source of limestone and to seawater, thus limiting AWL facilities within about 10 km of the coastline. The majority of U.S. coastal power generating facilities are within economical transport distance of limestone resources. AWL presents opportunities for collaborative efforts among the crushed stone industry, electrical utilities, cement manufactures, and research scientists.

  20. The "Global Heritage Stone Resource": Past, Present and Future

    Science.gov (United States)

    Cooper, Barry

    2013-04-01

    International Union of Geological Sciences (IUGS) in 2011 as its Heritage Stone Task Group (HSTG). The future is likely to hold further surprises. There could be benefits in establishing a permanent organisation or "Commission" within IUGS. There may also be value in preparing and maintaining an "International Guide to Heritage Stone Designation" that considers, not only those stone types that have international significance, but also those of national, regional and local importance. It is now considered that all dimension stone types may be considered a "potential heritage stone". Publications of all types that describe, discuss and promote nominated stone types will be beneficial. For good administration of the designation, the current HSTG "Terms of Reference" will likely require revision. For the immediate future, the major effort should focus on preparing and approving GHSR nominations. Over time the focus will likely move onto promoting community recognition of the designation, protecting recognised GHSRs and revising the existing heritage status of designated stones.

  1. Canada's National Building Stone: Tyndall Stone from Manitoba

    Science.gov (United States)

    Pratt, Brian R.; Young, Graham A.; Dobrzanski, Edward P.

    2016-04-01

    Tyndall Stone is a distinctively mottled and highly fossiliferous dolomitic limestone that belongs to the Selkirk Member of the Red River Formation, of Late Ordovician (Katian) age. It has been quarried at Garson, Manitoba, 37 km northeast of Winnipeg, since 1895, although other quarries in the area go back to 1832. Tyndall Stone, so named because it was shipped by rail from nearby Tyndall, is currently produced by Gillis Quarries Limited. It has various uses as a dimension stone. Large slabs, most often cut parallel to bedding, face the exterior or interior of many important buildings such as the Parliament Buildings and the Canadian Museum of Civilization in the Ottawa area, the Empress Hotel in Victoria, and the provincial legislatures in Winnipeg and Regina, as well as many commercial buildings especially in the Canadian prairies. At the quarries, the stone is cut vertically, using eight foot (2.44 m) diameter saws mounted on one hundred foot (30.5 m) tracks, then split into 6-8 tonne blocks that are moved using front-end loaders. Gillis Quarries operates a large finishing plant with an area of about 4000 m2. Stone is processed along advanced cutting lines that feature eight primary saws and six gantry saw stations, allowing it to be made into a variety of sizes, shapes, and finishes. The Selkirk Member is 43 m thick and the stone is extracted from a 6-8 m thick interval within the lower part. The upper beds tend to be more buff-coloured than the grey lower beds due to weathering by groundwater. The stone is massive, but extracted blocks are less than ~1m thick due to splitting along stylolites. Consisting of bioturbated wackestone to packstone, the Tyndall Stone was deposited in a shallow-marine environment within the photic zone, in the central part of the vast equatorial epicontinental sea that covered much of Laurentia. Scattered thin, bioclastic grainstone lenses record brief, low-energy storm events. The distinctive mottles are formed by dolomitized

  2. Comparative study of dose estimation in the change a conventional mammography to digital mammography

    International Nuclear Information System (INIS)

    Vazquez Vazquez, R.; Otero Martinez, C.; Soto Bua, M.; Santamarina Vazquez, F.; Carril Iglesias, S.; Lobato Busto, R.; Luna Vega, V.; Mosquera Sueiro, J.; Sqanchez Garcia, M.; Pombar Camean, M.

    2011-01-01

    Mammographic studies are now one of the most demanding radiological because of its effectiveness in detecting breast cancer early. The introduction of digital mammography has been a major advance because it has overcome some of the limitations of conventional systems. Due to the nature of the radiosensitive glandular tissue becomes very important control of the dose given to patients. In the present study is to analyze the variations in dosimetry that can exist between a conventional mammography and digital mammography.

  3. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study.

    Science.gov (United States)

    Skaane, Per; Young, Kari; Skjennald, Arnulf

    2003-12-01

    To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.

  4. Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography.

    Science.gov (United States)

    Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I

    2014-10-01

    Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.

  5. Ornamental Stones and Gemstones: The limits of heritage stone designation: The case for and against Australian Precious Opal

    Science.gov (United States)

    Cooper, Barry

    2015-04-01

    When the international designation of natural stone types was first mooted in 2007, stones that were utilised in building and construction were the primary focus of attention. However following public discussion it soon became apparent that sculptural stones, stone used for utilitarian purposes such as millstones, as well as archaeological materials including stones used by early man could all be positively assessed as a potential Global Heritage Stone Resource (GHSR). Over the past 2 years it has been realised there is also a range of ornamental and semi-precious stones that may also be considered in the same international context. Examples in this respect include Imperial Porphyry sourced from Egypt that was much prized in the ancient world and "Derbyshire Blue John" a variety of fluorspar from central England that was used for vases, chalices, urns, candle sticks, jars, bowls door, jewellery and fire-place surrounds, especially in the 18th and 19th centuries. It is at this point that rock materials, sometimes used as gemstones, impinge on the domain of typical heritage stones. In Australia, the gemstone most identifiable with the country is precious opal formed by sedimentary processes in the Great Artesian Basin. In this paper the question is asked whether "Australian Precious Opal" could be or should be considered as a heritage stone of international significance. Immediately Australian Precious Opal satisfies several GHSR criteria including historic use for more than 50 years and wide-ranging utilisation for prestige jewellery around the world. It is also recognised as a cultural icon including association with national identity in Australia as it is legally defined as Australia's "National Gemstone" as well as being the "Gemstone Emblem" for the State of South Australia. Opal continues to be mined. Designation of Australian Precious Opal as a Global Heritage Stone Resource would likely involve formal international recognition of Australian opal in the

  6. Fire effects on flaked stone, ground stone, and other stone artifacts [Chapter 4

    Science.gov (United States)

    Krista Deal

    2012-01-01

    Lithic artifacts can be divided into two broad classes, flaked stone and ground stone, that overlap depending on the defining criteria. For this discussion, flaked stone is used to describe objects that cut, scrape, pierce, saw, hack, etch, drill, or perforate, and the debris (debitage) created when these items are manufactured. Objects made of flaked stone include...

  7. Digital mammography; Mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, M.; Torres, R.

    2010-07-01

    Mammography represents one of the most demanding radiographic applications, simultaneously requiring excellent contrast sensitivity, high spatial resolution, and wide dynamic range. Film/screen is the most widely extended image receptor in mammography due to both its high spatial resolution and contrast. The film/screen limitations are related with its narrow latitude, structural noise and that is at the same time the medium for the image acquisition, storage and presentation. Several digital detector made with different technologies can overcome these difficulties. Here, these technologies as well as their main advantages and disadvantages are analyzed. Also it is discussed its impact on the mammography examinations, mainly on the breast screening programs. (Author).

  8. COMPARISON OF CR MAMMOGRAPHY, SONOMAMMOGRAPHY AND REAL-TIME ELASTOGRAPHY IN EVALUATING BREAST LESIONS

    Directory of Open Access Journals (Sweden)

    Onteddu Joji Reddy

    2016-11-01

    Full Text Available BACKGROUND Breast cancer is the most common cause of cancer deaths in women worldwide. As early detection can decrease the deaths due to breast cancer, high sensitive and specific tests are necessary to evaluate breast lesions. MATERIALS AND METHODS 80 patients with complaint of pain or lump in the breast or nipple discharge were evaluated by mammography, sonomammography and real-time elastography. Imaging studies were compared with the FNAC/biopsy of lesions. RESULTS Mammography has sensitivity, specificity, PPV, NPV as 80%, 95.5%, 93.3%, 86%, respectively. Sonomammography has sensitivity, specificity, PPV, NPV as 74.2%, 91%, 86%, 82%, respectively. Real-time elastography has sensitivity, specificity, PPV, NPV as 91.4%, 94.4%, 94.1%, 91.8%, respectively. Combined mammography and sonomammography has sensitivity, specificity, PPV, NPV as 82.8%, 93.3%, 90.6%, 87.5%, respectively. Combined sonomammography and elastography has sensitivity, specificity, PPV, NPV as 91.4%, 97.2%, 96.96%, 92.1%, respectively. CONCLUSIONS Combination of CR mammography, sonomammography and real-time elastography has high diagnostic sensitivity and specificity in the diagnosis of benign and malignant breast masses obviating the use of higher modalities like MRI, CAD and digital tomosynthesis, which is very useful in resource poor countries like India.

  9. FDA & digital mammography: why has FDA required full field digital mammography systems to be regulated as potentially dangerous devices for more than 10 years?

    Science.gov (United States)

    Nields, Morgan W

    2010-05-01

    Digital mammography is routinely used in the US to screen asymptomatic women for breast cancer and currently over 50% of US screening centers employ the technology. In spite of FDAs knowledge that digital mammography requires less radiation than film mammography and that its equivalence has been proven in a prospective randomized trial, the agency has failed to allow the technology market access via the 510(k) pre market clearance pathway. As a result of the restrictive Pre Market Approval process, only four suppliers have received FDA approval. The resulting lack of a competitive market has kept costs high, restricted technological innovation, and impeded product improvements as a result of PMA requirements. Meanwhile, at least twelve companies are on the market in the EU and the resulting competitive market has lowered costs and provided increased technological choice. A cultural change with new leadership occurred in the early 90's at FDA. The historical culture at the Center for Devices and Radiological Health of collaboration and education gave way to one characterized by a lack of reliance on outside scientific expertise, tolerance of decision making by unqualified reviewers, and an emphasis on enforcement and punishment. Digital mammography fell victim to this cultural change and as a result major innovations like breast CT and computer aided detection technologies are also withheld from the market. The medical device law, currently under review by the Institute of Medicine, should be amended by the Congress so that new technologies can be appropriately classified in accordance with the risk based assessment classification system detailed in Chapter V of the Federal Food, Drug, and Cosmetic Act. A panel of scientific experts chartered by the NIH or IOM should determine the classification appropriate for new technologies that have no historical regulatory framework. This would be binding on FDA. Unless the law is changed we will likely again experience

  10. Production and characterization of composite stone

    International Nuclear Information System (INIS)

    Leirose, G.D.; Lameiras, F.S.

    2012-01-01

    Composite stone is a product similar to natural granite or marble, produced with particles of these materials. This material is used like natural stone as lining. The fabrication of artificial stones using residues of banded iron formations is a promising alternative to its actual destination (storage in dam). This research aims the characterization of composite stone to prove the efficacy of this kind of processing. It was used first, natural quartz as a raw material. The patterns of the samples were confirmed by IR spectra and XRD patterns, ensuring the reproducibility of processing applied. Moreover, this material is homogeneous, with low porosity and high flexural strength, confirmed by its structural characterization. Thus, it can be affirmed that the process chosen is suitable, enabling the application of this methodology to the use of waste. (author)

  11. A local isotropic/global orthotropic finite element technique for modeling the crush of wood in impact limiters

    International Nuclear Information System (INIS)

    Attaway, S.W.; Yoshimura, H.R.

    1989-01-01

    Wood is often used as the energy absorbing material in impact limiters, because it begins to crush at low strains, then maintains a near constant crush stress up to nearly 60% volume reduction, and then locks up. Hill (Hill and Joseph, 1974) has performed tests that show that wood is an excellent absorber. However, wood's orthotropic behavior for large crush is difficult to model. In the past, analysts have used isotropic foam-like material models for modeling wood. A new finite element technique is presented in this paper that gives a better model of wood crush than the model currently in use. The orthotropic technique is based on locally isotropic, but globally orthotropic (LIGO) (Attaway, 1988) assumptions in which alternating layers of hard and soft crushable material are used. Each layer is isotropic; however, by alternating hard and soft thin layers, the resulting global behavior is orthotropic. In the remainder of this paper, the new technique for modeling orthotropic wood crush will be presented. The model is used to predict the crush behavior for different grain orientations of balsa wood. As an example problem, an impact limiter containing balsa wood as the crushable material is analyzed using both an isotropic model and the LIGO model

  12. Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography

    International Nuclear Information System (INIS)

    Baldelli, P; Bravin, A; Maggio, C Di; Gennaro, G; Sarnelli, A; Taibi, A; Gambaccini, M

    2006-01-01

    Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml -1 and 1.34 mg ml -1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml -1 and 1.31 mg ml -1 . With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml -1 (8 mm diameter) and 5.75 mg ml -1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml -1 (8 mm diameter) and 1.57 mg ml -1 (5 mm diameter)

  13. One more hurdle to increasing mammography screening: pubescent, adolescent, and prior mammography screening experiences.

    Science.gov (United States)

    Thomas, Eileen; Usher, LaToya

    2009-01-01

    Approximately $8.1 billion dollars is spent each year in the United States alone on the treatment of breast cancer. Survival rates are dependent on access to, and utilization of, early detection services. The primary reason for disparity in breast cancer mortality is the delay in time to diagnosis, resulting in poor prognosis. Despite ongoing research to understand barriers to mammography screening, recent studies report a decrease in mammography screening among all racial groups. A qualitative approach was used to elicit information from 36 White non- Hispanic, African-American, Hispanic, and Native American women without a history of breast cancer. Women were invited to share written or audiotape-recorded narratives about experiences pertaining to their breasts and their mammography screening experiences. Major categories identified were: teasing, family norms and values, media/societal influence, body image, and mammography screening experiences. The resulting effects of these experiences left these women with feelings of shame and "conflict" regarding their breasts. The major theme identified was breast conflict. Findings suggest that breast conflict may persist throughout the lifespan and can have a negative influence on a woman's decision to participate in mammography screening. The authors hypothesize that experiences that occur during adolescence pertaining to young girls' breasts can influence a women's body image, which in turn can later in life affect health-seeking behaviors related to mammography screening. These findings have implications for public health practice in planning for breast cancer screening, education, and interventions for women from diverse racial/ethnics groups.

  14. Effects of a risk-based online mammography intervention on accuracy of perceived risk and mammography intentions.

    Science.gov (United States)

    Seitz, Holli H; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M; Armstrong, Katrina; Cappella, Joseph N

    2016-10-01

    This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. 2918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (<1.5%; ≥1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) x 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk ≤1.5%. For women with a risk≤1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Valorization procedure of x-ray equipment in the mammography equipment

    International Nuclear Information System (INIS)

    Ruiz, M. A.; Ordonez, J.; Antolin, E.; Andres, J. C. de; Gonzalez, I.; Arranz, L.; Sastre, J. M.; Ferrer, N.

    2006-01-01

    The Ramon y Cajal Hospital mammography service has three X-rays units, two of them with high resolution computed radiography (CR) system and one with flat-panel (FP)-based full-field digital mammography system. Periodic control dose tests in patients have shown lower glandular dose levels (DGM) than references provided by European Protocol for de Quality Control of de Physical and Technical Aspects of Mammography Screening. In this work, we have tried to establish an easy method for DGM calculation which is representative of the three equipment results. For this aim, we have defined an index which is measured along the time like a reference point. This index is defined as the relation between the blind test punctuations of a standard phantom image given by at least three radiologists in the Unit, and the average DGM values obtained in 20 patients in each Unit (using random thickness and random mama composition). (Author)

  16. Villamayor stone (Golden Stone) as a Global Heritage Stone Resource from Salamanca (NW of Spain)

    Science.gov (United States)

    Garcia-Talegon, Jacinta; Iñigo, Adolfo; Vicente-Tavera, Santiago

    2013-04-01

    Villamayor stone is an arkosic stone of Middle Eocene age and belongs to the Cabrerizos Sandstone Formation that comprising braided fluvial systems and paleosoils at the top of each stratigraphic sequence. The sandstone is known by several names: i) the Villamayor Stone because the quarries are located in Villamayor de Armuña village that are situated at 7 km to the North from Salamanca city; ii) the Golden Stone due to its patina that produced a ochreous/golden color on the façades of monuments of Salamanca (World Heritage City,1988) built in this Natural stone (one of the silicated rocks utilised). We present in this work, the Villamayor Stone to be candidate as Global Heritage Stone Resource. The Villamayor Stone were quarrying for the construction and ornamentation of Romanesque religious monuments as the Old Cathedral and San Julian church; Gothic (Spanish plateresc style) as the New Cathedral, San Esteban church and the sculpted façade of the Salamanca University, one of the oldest University in Europe (it had established in 1250); and this stone was one of the type of one of the most sumptuous Baroque monuments is the Main Square of the its galleries and arcades (1729). Also, this stone was used in building palaces, walls and reconstruction of Roman bridge. Currently, Villamayor Stone is being quarried by small and family companies, without a modernized processing, for cladding of the façades of the new buildings until that the construction sector was burst (in 2008 the international economic crisis). However, Villamayor Stone is the main stone material used in the city of Salamanca for the restoration of monuments and, even in small quantities when compared with just before the economic crisis, it would be of great importance for future generations protect their quarries and the craft of masonry. Villamayor Stone has several varieties from channels facies to floodplains facies, in this work the selected varieties are: i) the fine-grained stone

  17. A study on the industrialization of building stones and industrial stone crafts - Study on the causes of stone contaminations

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Jeon Ki; Lee, Han Yeang [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    Causes of building stone contamination are acid rains in polluted areas, iron bearing minerals in stone itself, salts, sealants, cutting and grinding processes in stone factory and steel compounds structures such as stone anchors, bolts, rain culvert and guide frames. Contaminations on the building stone surface of Sejong culture center can be found around floor stones, stair stones, parterre stones, pillar stones and other outdoor stone panels. The parterre stones are contaminated by white tarnishes and rust flows are occurred on the surface of pillar stones and outdoor stone panels around entrance. Black tarnishes are cumulated on the pillar stones and other outdoor decorated stone panels and change the original granite color. Causes of building stone contaminations from Sejong culture center are wet method to attach stone panels, rust from steel compounds structures and air pollutants. Cement and mortar used from wet method react with sulfur dioxides in polluted air and from fine calcite crystals (white tarnish). Rusts from steel compounds structures such as rainwater culvert and steel guide frames can move to the stone surface by rain and leave rust flows on it. Pollutants (tar compounds, carbons, dusts, etc.) in air are cumulated with humidity on the stone surface and change color from white granite color to dusty dark color. Historical stone sculptures such as man and animal shaped stone crafts, tombstones, square stone tables in front of a tomb and guide and circumference stones around tomb in Royal Tombs (Donggu rung, Yung rung, Seoou rung and Hunin rung) distributed in Kyunggi province are contaminated by various moss and air pollutants and its original colors are deeply changed. (author). 21 refs., 11 tabs., 22 figs.

  18. 27 CFR 24.176 - Crushing and fermentation.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Crushing and fermentation..., DEPARTMENT OF THE TREASURY LIQUORS WINE Production of Wine § 24.176 Crushing and fermentation. (a) Natural... fermentation but the density of the juice may not be reduced below 22 degrees Brix. However, if the juice is...

  19. Screening mammography uptake within Australia and Scotland in rural and urban populations.

    Science.gov (United States)

    Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M; Henderson, Robert; Watson, Angus; Kyle, Richard G; Hubbard, Gill; Mullen, Russell; Atherton, Iain

    2015-01-01

    To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946-51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06-1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01-1.31). The absence of rural-urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography.

  20. [Comparison of DK crush with classical crush technique with drug-eluting stents for the treatment of coronary bifurcation lesions from DKCRUSH-1 study].

    Science.gov (United States)

    Chen, Shao-liang; Zhang, Jun-jie; Ye, Fei; Chen, Yun-dai; Lü, Shu-zheng; Tan, Huaycheem; Patel, Tejas; Kenji, Kawajiri; Tamari, Israel; Shan, Shou-jie; Zhu, Zhong-sheng; Lin, Song; Tian, Nai-liang; Li, Xiao-bo; Liu, Zhi-zhong; Lee, Michael; Wei, Meng; Xu, Ya-wei; Yuan, Zheng-bai; Qian, Jun; Sun, Xue-wen; Yang, Song; Chen, Jin-guo; He, Ben; Sumit, Suji

    2008-02-01

    To determine independent factors correlated with clinical effects of DK crush and classical crush technique with drug-eluting stents on bifurcation lesions. 311 patients with bifurcation lesions were randomized to classical (C, n = 156) or double kissing (DK) crush (n = 155) stent implantation group. The primary endpoints included major adverse cardiac events (MACE). Final kissing balloon inflation (FKBI) success rate was 76% in C and 100% in DK groups (P DK crush procedure was characterized by lower unsatisfactory FKBI rate (27.6% vs.6.3%, P DK groups (P = 0.01), respectively. Cumulative 8-month MACE was 35.9% in without-FKBI and 19.7% in with-FKBI sub-groups, and 11.4% in DK group (P = 0.02). The incidence of stent thrombosis was 3.2% in C group (5.1% without vs. 1.7% with FKBI) and 1.3% in DK group (P > 0.05). The predictive factors of MACE included minimal side branch stent lumen diameter and lack of DK crush technique. DK crush technique is an alternative of double stenting techniques in terms of improvement of restenosis and clinical outcomes.

  1. Mammography: MedlinePlus Health Topic

    Science.gov (United States)

    ... Questions (National Cancer Institute) Mammography for Women with Breast Implants (American Cancer Society) Also in Spanish Mammography: What You Need to Know (Food and Drug Administration) Nipple Aspirate Test Is ... Specifics Breast Tomosynthesis (American College of Radiology, Radiological Society of ...

  2. Application of phase contrast imaging to mammography

    International Nuclear Information System (INIS)

    Tohyama, Keiko; Yamada, Katsuhiko; Katafuchi, Tetsuro; Matsuo, Satoru; Morishita, Junji

    2005-01-01

    Phase contrast images were obtained experimentally by using a customized mammography unit with a nominal focal spot size of 100 μm and variable source-to-image distances of up to 1.5 m. The purpose of this study was to examine the applicability and potential usefulness of phase contrast imaging for mammography. A mammography phantom (ACR156 RMI phantom) was imaged, and its visibility was examined. The optical density of the phantom images was adjusted to approximately 1.3 for both the contact and phase contrast images. Forty-one observers (18 medical doctors and 23 radiological technologists) participated in visual evaluation of the images. Results showed that, in comparison with the images of contact mammography, the phantom images of phase contrast imaging demonstrated statistically significantly superior visibility for fibers, clustered micro-calcifications, and masses. Therefore, phase contrast imaging obtained by using the customized mammography unit would be useful for improving diagnostic accuracy in mammography. (author)

  3. Mammography

    Science.gov (United States)

    ... breast cancer Whether there is any harm from breast cancer screening, such as side effects from testing or overtreatment of cancer when it's discovered Mammography is performed to screen women to detect early breast cancer when it is ...

  4. Stone fragmentation by ultrasound

    Indian Academy of Sciences (India)

    Unknown

    In the present work, enhancement of the kidney stone fragmentation by using ultrasound is studied. The cavi- ... ment system like radiation pressure balance, the power is given by ... Thus the bubble size has direct relationship with its life and.

  5. Evaluation of crushed ticagrelor tablet doses: recovery following crushing and naso-gastric tube passage ex vivo.

    Science.gov (United States)

    Crean, Barry; Finnie, Cindy; Crosby, Anna

    2013-06-01

    Orally available ticagrelor in combination with low-dose aspirin (75-100 mg/day) is indicated for adult patients with acute coronary syndromes. However, patients with swallowing difficulties may be unable to consume the currently available 90-mg tablet. It is hypothesized that ticagrelor could be given to this patient cohort as a crushed dose administered either orally or via a naso-gastric (NG) tube. To investigate the potential use of crushed ticagrelor tablets (90- and 180-mg doses) for oral dose or NG tube administration. Ticagrelor tablets (90 or 180 mg [two 90-mg tablets]) were prepared to emulate oral and NG tube administration by similar methods. For the oral dose, ticagrelor tablets were crushed using a mortar and pestle and transferred to a dosing cup. 100 mL of water was added to the mortar, stirred, and the contents were transferred to the dosing cup and stirred to form a suspension. At this stage, where the suspension would normally be administered to a patient, it was collected for high performance liquid chromatography (HPLC) analysis. The mortar was then flushed with 100 mL of water, and the contents were again transferred to the dosing cup, stirred, and collected for HPLC analysis. For the NG dose, polyvinylchloride, polyurethane, and silicone size CH10 NG tubes were used. The tablets were crushed using a mortar and pestle, diluted with 50 mL of water, and stirred. At this stage, where the suspension would normally be administered to a patient through an NG tube using a syringe, it was collected for HPLC analysis. The mortar was then flushed with two additional 50 mL aliquots of water and the contents were passed through the NG tube. HPLC analysis examined the recoverability of ticagrelor in each of the dose suspensions and flushes and the stability of the suspension when held in a syringe for up to 2 h. One or two crushed 90-mg ticagrelor tablets, prepared for either oral or NG tube administration, delivers a mean dose of ≥97% of the original

  6. Cost-effectiveness of increasing access to mammography through mobile mammography for older women.

    Science.gov (United States)

    Naeim, Arash; Keeler, Emmett; Bassett, Lawrence W; Parikh, Jay; Bastani, Roshan; Reuben, David B

    2009-02-01

    To compare the costs of mobile and stationary mammography and examine the incremental cost-effectiveness of using mobile mammography to increase screening rates. A cost-effectiveness analysis was performed using effectiveness data from a randomized clinical trial and modeling of costs associated with the mobile mammography intervention. The trial involved 60 community-based meal sites, senior centers, and clubs. Four hundred ninety-nine individuals were enrolled in the study, of whom 463 had outcome data available for analysis. Costs were calculated for stationary and mobile mammography, as well as costs due to differences in technology and film versus digital. Incremental cost-effectiveness (cost per additional screen) was modeled, and sensitivity analysis was performed by altering efficiency (throughput) and effectiveness based on subgroup data from the randomized trial. The estimated annual costs were $435,162 for a stationary unit, $539,052 for a mobile film unit, and $456, 392 for a mobile digital unit. Assuming mobile units are less efficient (50% annual volume), the cost per screen was $41 for a stationary unit, $86 for a mobile film unit, and $102 for a mobile digital unit. The incremental cost per additional screen were $207 for a mobile film unit and $264 for a mobile digital unit over a stationary unit. Although mobile mammography is a more effective way to screen older women, the absolute cost per screen of mobile units is higher, whereas the reimbursement is no different. Financial barriers may impede the widespread use of this approach.

  7. Study on patient exposure from mammography, 3

    International Nuclear Information System (INIS)

    Sato, Miyao

    1983-01-01

    Risks and benefits of the patient from mammography performed in Japan were estimated, and the indication of mammography were discussed. 1) Breast cancers induced by mammography were estimated based on the average breast dose, the average life span, risks of radiation-induced breast cancer and the breast cancer significant factor. 2) The breast cancer significant factor was calculated, similar to those of leukemia significant factor by Hashizume, from latent periods of radiation-induced breast cancer and the excess breast cancer induction rate in female A-bomb survivors. 3) Numbers of the deaths and Lost-years were calculated from risks of radiation-induced breast cancer, incidence of breast cancer by mammography, cure rate of breast cancer, average life span and latent period of radiation-induced breast cancer. 4) Numbers of the increased life and years saved were calculated from the improved rate of the ability of diagnosis, frequency of mammography, the average life span and cure rate of breast cancer. 5) Induction of leukemia, lung cancer and thyroid cancer by mammography also were investigated. Its contribution was not significant, compared to the induction of breast cancer. 6) Comparing risk and benefit, the latter was much higher than the former by factors of 71-76. This was suggested the efficacy of mammography. 7) From a pointview of risk and benefit, routine mammography is contraindicative for 10-19 years old women because of large risk, the indication must be scrutinized for 20-29 years old ones, and the benefit increases with age for over 30 years old ones so that mammography was positively admitted for the symptomatic women. (author)

  8. Does gender discrimination impact regular mammography screening? Findings from the race differences in screening mammography study.

    Science.gov (United States)

    Dailey, Amy B; Kasl, Stanislav V; Jones, Beth A

    2008-03-01

    ABSTRACT Objective: To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. African American and white women (1451) aged 40-79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of > or =$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women.

  9. Coke properties in relation to charge preparation techniques. [Selective crushing

    Energy Technology Data Exchange (ETDEWEB)

    Morozov, O S

    1979-01-01

    Selective crushing is essential to obtain the required coke properties, so that in the coarse fractions there is a considerable reduction in the middlings and dirt normally difficult to crush. These are at the same time enriched with vitrinite so that there is an increase in the coal substance as such, reflected in improved caking capacity in the coarse size range. Various methods of selective crushing are employed, including air entrainment mills, fluidised bed systems. Other advantages claimed for selective crushing are the uniform pore distribution and air permeability and also the diminished breakage stress.

  10. Contrast-enhanced spectral mammography vs. mammography and MRI - clinical performance in a multi-reader evaluation

    NARCIS (Netherlands)

    Fallenberg, E.M.; Schmitzberger, F.F.; Amer, H.; Ingold-Heppner, B.; Balleyguier, C.; Diekmann, F.; Engelken, F.; Mann, R.M.; Renz, D.M.; Bick, U.; Hamm, B.; Dromain, C.

    2017-01-01

    OBJECTIVES: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) to digital mammography (MG) and magnetic resonance imaging (MRI) in a prospective two-centre, multi-reader study. METHODS: One hundred seventy-eight women (mean age 53 years) with invasive breast

  11. Slit aperture technique for mammography

    International Nuclear Information System (INIS)

    Friedrich, M.

    1984-01-01

    Following a discussion of various principles used in the elimination of scatter, the prototype of a simple slit aperture mammography apparatus is described (modified Mammomat, Siemens). The main advantage of this technique compared with grid mammography is a halving of the radiation dose for identical image quality, using an identical film system. The technical requirements (heavy duty tube, new generator) are, however, considerable. If the film-screen systems currently in use are to remain the common systems for the future, then the development of a multi-lamellar slit diaphragm technique carries much promise for mammography. (orig.) [de

  12. Digital mammography and their developments

    International Nuclear Information System (INIS)

    Wienbeck, Susanne

    2015-01-01

    At the present time digital mammography is a satisfactory breast diagnostic imaging in clinical as well as screening mammography in defined age groups. Nevertheless it shows beside the application of ionizing radiation in women with dense breasts limitations in the detection of non calcification breast cancers. Tomosynthesis, digital contrast-enhanced mammography and breast-CT with or without contrast media lead to better results. Especially the application of contrast media for the visualisation of the tumor angiogenesis is invariably superior to all other non-contrast imaging modalities. However, the excellent results of breast MRI will be probably accessible with none of the new procedures.

  13. Topological anisotropy of stone-wales waves in graphenic fragments.

    Science.gov (United States)

    Ori, Ottorino; Cataldo, Franco; Putz, Mihai V

    2011-01-01

    Stone-Wales operators interchange four adjacent hexagons with two pentagon-heptagon 5|7 pairs that, graphically, may be iteratively propagated in the graphene layer, originating a new interesting structural defect called here Stone-Wales wave. By minimization, the Wiener index topological invariant evidences a marked anisotropy of the Stone-Wales defects that, topologically, are in fact preferably generated and propagated along the diagonal of the graphenic fragments, including carbon nanotubes and graphene nanoribbons. This peculiar edge-effect is shown in this paper having a predominant topological origin, leaving to future experimental investigations the task of verifying the occurrence in nature of wave-like defects similar to the ones proposed here. Graph-theoretical tools used in this paper for the generation and the propagation of the Stone-Wales defects waves are applicable to investigate isomeric modifications of chemical structures with various dimensionality like fullerenes, nanotubes, graphenic layers, schwarzites, zeolites.

  14. Comparative evaluation of average glandular dose and image of digital mammography and film mammography in Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Nogueira, M.; Leyton, F.; Rodrigue, L. L.C.; Oliveira, M.A.; Joana, G.S.; Silva, S.D.

    2015-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The purpose of our study was to compare the technical performance of digital mammographic and screen-film mammography. A PMMA phantom with objects to simulate breast structures. For the screen/film (SF) technique the results showed that 54% mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 67% services showed inadequate performance in their processing systems, which had significant influence on the image quality. At the mean glandular dose only 44% of digital systems evaluated were compliant in all thicknesses of PMMA. The average glandular dose AGD was 90 % higher than in screen/film systems. (authors)

  15. Image quality in mammography

    International Nuclear Information System (INIS)

    Haus, A.G.; Doi, K.; Metz, C.E.; Bernstein, J.

    1976-01-01

    In mammography, image quality is a function of the shape, size, and x-ray absorption properties of the anatomic part to be radiographed and of the lesion to be detected; it also depends on geometric unsharpness, and the resolution, characteristic curve and noise properties of the recording system. X-ray energy spectra, modulation transfer functions, Wiener spectra, characteristic and gradient curves, and radiographs of a breast phantom and of a resected breast specimen containing microcalcifications are used in a review of some current considerations of the factors, and the complex relationship among factors, that affect image quality in mammography. Image quality and patient radiation exposure in mammography are interrelated. An approach to the problem of evaluating the trade-off between diagnostic certainty and the cost or risk of performing a breast imaging procedure is discussed

  16. [Usefullness of the StoneBreaker lithotripter for percutaneous nephrolithotomy].

    Science.gov (United States)

    del Peso, Almudena Coloma; González, Inmaculada Fernández; Gálvez, Milagros Jiménez; Abad, Pablo Garrido; Fajardo, Gloria Bocardo; Fernández, Luis Miguel Herranz; Arjona, Manuel Fernández; Torres, Lorenzo Herrero; Sanz, Ignacio Pereira

    2008-01-01

    Throughout the history, many devices have been used for breaking urinary tract stones. StoneBreaker (LMA Urology, Gland, Switzerland) is a second generation of intracorporeal lithotripter, pneumatic and portable, which adds several new advantages, like effectiveness in stone fragmentation and easy handling, very useful during percutaneous lithotripsy. We report the case of a 40 year-old male patient, with a left kidney pyelic lithiasis, who was treated by percutaneous lithotripsy, under general anaesthesia, with StoneBreaker (LMA Urology, Gland, Switzerland) as lithotripter. StoneBreaker (LMA Urology, Gland, Switzerland) is a lithotripter usable with rigid and semirigid ureteroscopes, much more powerful than its predecessors. It is able to decrease the number of shocks necessary for stone fragmentation, without bigger tissue reaction. It also has a more comfortable design due to the absence of connections, and its power by replaceable carbon dioxide cartridges.

  17. Evidence on Synthesized Two-dimensional Mammography Versus Digital Mammography When Using Tomosynthesis (Three-dimensional Mammography) for Population Breast Cancer Screening.

    Science.gov (United States)

    Houssami, Nehmat

    2017-09-28

    One limitation of using digital breast tomosynthesis (3-dimensional [3D] mammography) technology with conventional (2-dimensional [2D]) mammography for breast cancer (BC) screening is the increased radiation dose from dual acquisitions. To resolve this problem, synthesized 2D (s2D) reconstruction images similar to 2D mammography were developed using tomosynthesis acquisitions. The present review summarizes the evidence for s2D versus digital mammography (2D) when using tomosynthesis (3D) for BC screening to address whether using s2D instead of 2D (alongside 3D) will yield similar detection measures. Comparative population screening studies have provided consistent evidence that cancer detection rates do not differ between integrated 2D/3D (range, 5.45-8.5/1000 screens) and s2D/3D (range, 5.03-8.8/1000 screens). Also, although the recall measures were relatively heterogeneous across included studies, little difference was found between the 2 modalities. The mean glandular dose for s2D/3D was 55% to 58% of that for 2D/3D. In the context of BC screening, s2D/3D involves substantially less radiation than 2D/3D and provides similar detection measures. Thus, consideration of transitioning to tomosynthesis screening should aim to use s2D/3D to minimize harm. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Franco E, J.G. [UAM-Xochimilco, 04960 Mexico D.F. (Mexico); Azorin N, J. [UAM-Iztapalapa, 09340 Mexico D.F. (Mexico); Diaz G, J.A.I. [CICATA, Unidad Legaria, Av. Legaria 694, 11599 mexico D.F. (Mexico); Arreola, M. [Department of Radiology, Shands Hospital at UF, PO Box 100374, Gainesville, FL 32610-0374 (United States)

    2006-07-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  19. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2006-01-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  20. Dual-energy contrast-enhanced mammography.

    Science.gov (United States)

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  1. Quality control of mammography departments in Slovakia

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.

    2007-01-01

    Complete test of publication follows. Considering the fact that mammary gland is the most sensitive organ to ionizing radiation, the Commission of the Ministry of Health of SR for QA in radiology organized a pilot two-run country wide audit conducted in 42 mammography departments that have met the beforehand criteria. During the audit the methods for establishing the individual parameters in technical and clinical part of quality assurance in mammography were elaborated and implemented. Technical and clinical parameters of the imaging process that mostly affect the quality of diagnostic information were followed up. These parameters included: the object thickness compensation, optical density deviation, evaluation of the film quality by means of special phantom, etc. Important measurement of ESDs at participating departments enabled to compare the radiation load of mammography patients in Slovakia with reference values in European guidelines. The uniform standard method for QA at mammography departments was elaborated and published as the regulation of the Ministry of Health for performance of preventive mammography examinations in SR. The presented results show the improved quality of mammography examinations due to regular check-ups of technical and clinical parameters and fulfilment of the required values in all parameters. The audit results are the basis for continuous quality assessment of mammography departments as a main prerequisite for conducting preventive examinations and for health insurance purposes.

  2. Data on the cost-benefit analysis of mammography

    International Nuclear Information System (INIS)

    Zarand, P.; Pentek, Z.

    1982-01-01

    The radiation exposure and the cost per examination are compared in the case of three methods: non-screen film mammography, 10-dose mammography and xeromammography. 10-dose mammography results in the lowest radiation exposure whereas xeromammography has the lowest cost. (L.E.)

  3. Sonographic differentiation of pneumobilia from intrahepatic stone: U.F.O. sign

    International Nuclear Information System (INIS)

    Han, Sang Suk; Kim, S. S.; Kwon, D. Y.; Kim, C. D.; Cha, S. S.; Jeon, J. R.; Jung, D. H.

    1990-01-01

    Pneumobilia is one of the most troublesome problem in the sonographic examination of the hepatobiliary system, and the differentiation of air from intrahepatic stone is very important. We have analyzed the sonographic characteristics of 42 cases of pneumobilia dn 56 cases of intrahepatic stones over a period of 4 years. New findings of pneumobilia we observed were U.F.O. sign, wing like artefact, and nonvisualization of the lumen of the bile filled duct. Findings of pneumobilia only were U.F.O. sign, nng down and wing like artefact. Findings of stone only were ecdhogenic foci larger than 1.5cm, heterogeneous echo, wedge, shell, or sandwich like contour, and visible lumen of the bile duct

  4. Advanced Breast Cancer as Indicator of Quality Mammography

    International Nuclear Information System (INIS)

    Gaona, Enrique

    2003-01-01

    Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is the more important screening tool for detecting early breast cancer. Screening mammography involves taking x-rays from two views from each breast, typically from above (cranial-caudal view, CC) and from an oblique or angled view (mediolateral-oblique, MLO). The purpose of this study was to carry out an exploratory survey of the issue of patients with advanced breast cancer who have had a screening mammography. A general result of the survey is that 22.5% of all patients (102) with advanced breast cancer that participated in the study had previous screening mammography. But we should consider that 10% of breast cancers are not detected by mammography. Only 70% of the family doctors prescribed a diagnostic mammography when the first symptoms were diagnosed

  5. Mammography Facilities

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Mammography Facility Database is updated periodically based on information received from the four FDA-approved accreditation bodies: the American College of...

  6. Film-Screen Mammography versus digital storage plate mammography: Hard copy and monitor display of microcalcifications and focal findings - A retrospective clinical and histologic analysis

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Aichinger, U.; Tartsch, M.; Kuchar, I.; Bautz, W.

    2003-01-01

    Purpose: A retrospective clinical-histological study to determine the diagnostic accuracy of mammography using conventional screen-film cassettes (hard copy), high-resolution digital phosphor storage plates (hard copy) and monitor display (soft copy) for microcalcifications and focal lesions (BI-RADS TM category 4 or 5). Materials and methods: From April to November 2001, 76 patients underwent conventional film-screen mammography and, after diagnosis and preoperative wire localization, digital mammography with the same exposure parameters. Five investigators retrospectively determined the diagnosis after the operation from randomly distributed mediolateral views (hard-copy reading) and from the monitor display (soft-copy reading). These results were correlated with the final histology. Results: The accuracy of conventional screen-film mammography, digital mammography and monitor-displayed mammography was 67%, 65% and 68% for all findings, (n = 76), 59%, 59% and 68% for microcalcifications (n = 44) and 75%, 72% and 63% for focal lesions (n = 32). The overall results showed no difference. Conclusions: Our findings indicate equivalence of conventional screen-film mammography, high-resolution digital phosphor storage plate mammography and monitor-displayed mammography. (orig.) [de

  7. Computer assisted visualization of digital mammography images

    International Nuclear Information System (INIS)

    Funke, M.; Breiter, N.; Grabbe, E.; Netsch, T.; Biehl, M.; Peitgen, H.O.

    1999-01-01

    Purpose: In a clinical study, the feasibility of using a mammography workstation for the display and interpretation of digital mammography images was evaluated and the results were compared with the corresponding laser film hard copies. Materials and Methods: Digital phosphorous plate radiographs of the entire breast were obtained in 30 patients using a direct magnification mammography system. The images were displayed for interpretation on the computer monitor of a dedicated mammography workstation and also presented as laser film hard copies on a film view box for comparison. The images were evaluted with respect to the image handling, the image quality and the visualization of relevant structures by 3 readers. Results: Handling and contrast of the monitor displayed images were found to be superior compared with the film hard copies. Image noise was found in some cases but did not compromise the interpretation of the monitor images. The visualization of relevant structures was equal with both modalities. Altogether, image interpretation with the mammography workstation was considered to be easy, quick and confident. Conclusions: Computer-assisted visualization and interpretation of digital mammography images using a dedicated workstation can be performed with sufficiently high diagnostic accuracy. (orig.) [de

  8. Assessment of stone composition in the management of urinary stones

    NARCIS (Netherlands)

    Kijvikai, Kittinut; de la Rosette, J. J. M.

    2011-01-01

    Several explanations have been suggested to account for the failure of extracorporeal shockwave lithotripsy (ESWL) treatment in patients with urinary stones, including large stone volume, unfavorable stone location or composition and the type of lithotriptor used. Unfavorable stone composition is

  9. Investigation of actual conditions of mammography in Kagoshima prefecture

    International Nuclear Information System (INIS)

    Baba, Natsuki; Tanimoto, Eriko; Kobayashi, Yasuhiro; Kuma, Kouji

    2009-01-01

    We surveyed the actual conditions of mammography with regard to image quality and radiation dose at 44 facilities in Kagoshima prefecture in 1999. In April 2004, guidelines for mammography newly included the standard of digital mammography. From September to October 2005, the survey was conducted at 48 facilities, and the results of the survey were compared with that in 1999. We visited 44 of the 48 facilities, and visually evaluated the image quality of mammograms for RMI156 and clinical mammograms. In addition, we measured average mammary gland dose at each facility. The number of the mammography device that satisfied the specified guideline criterion was larger than that in 1999. Image quality for the RMI156 mammograms improved. However, the results of the present survey revealed several problems. First, the number of facilities that had quality control instruments for mammography are few. Second, radiological technologists, medical doctors, and nurses did not share knowledge or information regarding mammography. Finally, there were differences in devices and image quality for mammography among the facilities. We achieved an understanding of the actual conditions of mammography in Kagoshima prefecture by visiting many facilities, evaluating image quality, and communicating with many staff members. Our results may be useful for the development of mammography examinations. (author)

  10. A comparison of digital mammography detectors and emerging technology

    International Nuclear Information System (INIS)

    Diffey, J.L.

    2015-01-01

    The overall diagnostic accuracy of digital mammography in the context of screening has been shown to be similar or slightly better than screen-film mammography. However, digital mammography encompasses both Computed Radiography (CR) and integrated Digital Radiography (DR) and there is increasing evidence to suggest that differences in detector technology are associated with variations in cancer detection rate, dose and image quality. These differences are examined in detail. Although digital mammography offers many advantages compared to screen-film, there are still some limitations with its use as a screening tool and reduced cancer detection in dense breasts remains an issue. Digital mammography detectors have paved the way for emerging technologies which may offer improvements. Taking the definition of mammography to only include X-ray imaging of the breast, this article focuses on tomosynthesis, contrast-enhanced digital mammography, stereoscopic mammography and dedicated breast computed tomography. Advanced software applications such as Computed Aided Detection (CAD) and quantitative breast density assessment are also presented. The benefits and limitations of each technique are discussed. - Highlights: • Digital detector technology affects cancer detection rate, dose and image quality. • Digital detectors have facilitated new technologies such as tomosynthesis. • 3-D techniques reduce superimposition and increase cancer detection in dense breasts. • Contrast-enhanced mammography demonstrates improved sensitivity and specificity.

  11. Infection (urease) stones.

    Science.gov (United States)

    Griffith, D P; Osborne, C A

    1987-01-01

    Infection-induced stones in man probably form solely as a consequence of urealysis which is catalyzed by the bacterial protein urease. Urease stones composed of struvite and carbonate-apatite may form primarily, or as secondary stones or pre-existent metabolic stones. Struvite stones form and grow rapidly owing to (a) supersaturation of urine with stone forming salts, (b) 'salting out' of poorly soluble organic substances normally dissolved in urine and (c) ammonia-induced destruction of the normally protective urothelial glycosaminoglycan layer. Immature (predominantly organic) matrix stones mature into densely mineralized stones. Curative treatment is possible only by eliminating all of the stone and by eradicating all urinary and parenchymal infection. A variety of operative and pharmaceutical approaches are available. Patient treatment must be individualized inasmuch as some patients are better candidates for one type of treatment than another.

  12. Update on new technologies in digital mammography

    Directory of Open Access Journals (Sweden)

    Patterson SK

    2014-08-01

    Full Text Available Stephanie K Patterson, Marilyn A Roubidoux Division of Breast Imaging, Department of Radiology, University of Michigan Health System, Ann Arbor, MI, USA Abstract: Despite controversy regarding mammography's efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. Keywords: screening mammography, breast cancer, contrast media, digital breast tomosynthesis

  13. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  14. Trimodel Mammography with Perfect Coregistration

    Science.gov (United States)

    2017-02-01

    background, the major confounding factor in reading mammography; the imaging characteristics suggest that this contrast mechanism would be preferable...image with enhanced edges and reduced anatomical background, the major confounding factor in reading mammography; the imaging characteristics suggest...subjects, vertebrate animals , biohazards, and/or select agents Describe significant deviations, unexpected outcomes, or changes in approved protocols

  15. Image Quality and Patient Dose Optimisation in Mammography in Slovakia

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2003-01-01

    Breast cancer represents also in Slovakia the greatest cancer risk for women, with great incidence and mortality. Conventional film-screen mammography is still the primary breast imaging modality with increasing number of mammography units and mammography examinations. From the radiation protection point of view achievement of good practice in mammography department by implementation of quality assurance play an important role for reduction of patients doses. Introduction of QA needs trained and experienced staff and requires close collaboration between radiologists, medical physicist and radiographers. At the beginning of nineties at the Institute of Preventive and Clinical Medicine we started with a survey of mean glandular doses at 15 existing mammography units in the country. On the basis of a questionnaire in the year 1991 were performed 10 488 mammography examinations, where due to out of date mammography units the mean glandular dose reached more as 3 mGy. In the following years the claim to the modern mammography units kept growing and in the year 1999 the total number of 63 mammography units were operating in Slovakia providing about 101 471 mammography examinations. According to the alarming increase of the number of mammography examinations it is absolutely necessary to work out criteria and principles for Quality Control at mammography workplaces in our country and make it obligatory for the staff of all mammography units. Summarising the CRP results it can be stated that they: 1) Initiated the suggestion of unified QA/QC criteria in mammography and the urgent need to implement them into the national program of radiology image quality improvement; 2) Remitted on unhomogenity not only in the equipment outfit but also in the procedure of evaluation of the measured parameters and imaging quality; 3) Revealed the shortcomings in the everyday practice of mammography units which can be removed only by comprehensive by training of personal in imaging radiology

  16. Digital mammography: current state and future aspects

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, U.; Baum, F. [Womens Health Care Center Goettingen, Diagnostisches Brustzentrum Goettingen, Goettingen (Germany); Hermann, K.P. [Georg-August-Universitaet Goettingen, Abteilung Diagnostische Radiologie, Goettingen (Germany)

    2006-01-01

    The introduction of digital technique in mammography has been the last step in completing the process of digitalization in diagnostic imaging. Meanwhile, some different digital techniques as well as a couple of different digital mammography systems were developed and have already been available for some years. In this review article, the relevant data of key studies are reported, the current status is defined, and perspectives of digital mammography are described. (orig.)

  17. Mammography and breast sonography in transsexual women

    International Nuclear Information System (INIS)

    Weyers, S.; Villeirs, G.; Vanherreweghe, E.; Verstraelen, H.; Monstrey, S.; Van den Broecke, R.; Gerris, J.

    2010-01-01

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  18. Mammography and breast sonography in transsexual women

    Energy Technology Data Exchange (ETDEWEB)

    Weyers, S., E-mail: steven.weyers@ugent.b [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Villeirs, G.; Vanherreweghe, E. [Department of Radiology, Ghent University Hospital, Ghent (Belgium); Verstraelen, H. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Monstrey, S. [Department of Plastic Surgery, Ghent University Hospital, Ghent (Belgium); Van den Broecke, R.; Gerris, J. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium)

    2010-06-15

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  19. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  20. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts.

    Science.gov (United States)

    Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D

    2015-03-01

    To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.

  1. Do stone size and impaction influence therapeutic approach to proximal ureteral stones?

    Directory of Open Access Journals (Sweden)

    Radulović Slobodan

    2009-01-01

    Full Text Available Background/Aim. Primary therapeutic approach to lumbar ureteral stones is still contraversial. The aim of the study was to investigate the influence of stone impaction and size on the effectiveness of proximal ureteral stone lithotripsy. Methods. A total of 123 patients with proximal ureteral stones were investigated in this prospective study performed in a 10- month period. The patients were divided into the group I - 86 patients treated with extracorporeal shock wave lithotripsy (ESWL and the group II - 37 patients treated with 'Swiss' Lithoclast. In the group I, 49 stones (57% were classified as impacted, while 20 stones (23.3% were larger than 100 mm2. In the group II, 26 stones (70.3% were impacted, and 11 stones (29.7% were larger than 100 mm2. Stones were defined as impacted by the radiographic, echosonographic as well as endoscopic findings in the group II of patients. Stone size was presented in mm2. Chemical composition of stones were almost the same in both groups of the patients. Results. Generally, there was no statistically significant difference in the treatment success between the groups. However, stones larger than 100 mm2 were statistically more successfully treated endoscopically, while there was no statistical difference in the treatment success of impacted stones between these two groups. Conclusion. ESWL can by considered as primary first therapeutic approach in treatment of all proximal ureteral stones except for stones larger than 100 mm2 that should primarily be treated endoscopically.

  2. Characteristics of Crushing Energy and Fractal of Magnetite Ore under Uniaxial Compression

    Science.gov (United States)

    Gao, F.; Gan, D. Q.; Zhang, Y. B.

    2018-03-01

    The crushing mechanism of magnetite ore is a critical theoretical problem on the controlling of energy dissipation and machine crushing quality in ore material processing. Uniaxial crushing tests were carried out to research the deformation mechanism and the laws of the energy evolution, based on which the crushing mechanism of magnetite ore was explored. The compaction stage and plasticity and damage stage are two main compression deformation stages, the main transitional forms from inner damage to fracture are plastic deformation and stick-slip. In the process of crushing, plasticity and damage stage is the key link on energy absorption for that the specimen tends to saturate energy state approaching to the peak stress. The characteristics of specimen deformation and energy dissipation can synthetically reply the state of existed defects inner raw magnetite ore and the damage process during loading period. The fast releasing of elastic energy and the work done by the press machine commonly make raw magnetite ore thoroughly broken after peak stress. Magnetite ore fragments have statistical self-similarity and size threshold of fractal characteristics under uniaxial squeezing crushing. The larger ratio of releasable elastic energy and dissipation energy and the faster energy change rate is the better fractal properties and crushing quality magnetite ore has under uniaxial crushing.

  3. Mammography accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, P.

    1993-12-31

    In the mid-1980`s, the movement toward the use of dedicated mammography equipment provided significant improvement in breast cancer detection. However, several studies demonstrated that this change was not sufficient to ensure optimal image quality at a low radiation dose. In particular, the 1985 Nationwide Evaluation of X-ray Trends identified the wide variations in image quality and radiation dose, even from dedicated units. During this time period, the American Cancer Society (ACS) launched its Breast Cancer Awareness Screening Campaign. However, there were concerns about the ability of radiology to respond to the increased demand for optimal screening examinations that would result from the ACS program. To respond to these concerns, the ACS and the American College of Radiology (ACR) established a joint committee on mammography screening in 1986. After much discussion, it was decided to use the ACR Diagnostic Practice Accreditation Program as a model for the development of a mammography accreditation program. However, some constraints were required in order to make the program meet the needs of the ACS. This voluntary, peer review program had to be timely and cost effective. It was determined that the best way to address these needs would be to conduct the program by mail. Finally, by placing emphasis on the educational nature of the program, it would provide an even greater opportunity for improving mammographic quality. The result of this effort was that, almost six years ago, in May 1987, the pilot study for the ACR Mammography Accreditation Program (MAP) began, and in August of that year, the first applications were received. In November 1987, the first 3-year accreditation certificates were awarded.

  4. Mammography accreditation program

    International Nuclear Information System (INIS)

    Wilcox, P.

    1993-01-01

    In the mid-1980's, the movement toward the use of dedicated mammography equipment provided significant improvement in breast cancer detection. However, several studies demonstrated that this change was not sufficient to ensure optimal image quality at a low radiation dose. In particular, the 1985 Nationwide Evaluation of X-ray Trends identified the wide variations in image quality and radiation dose, even from dedicated units. During this time period, the American Cancer Society (ACS) launched its Breast Cancer Awareness Screening Campaign. However, there were concerns about the ability of radiology to respond to the increased demand for optimal screening examinations that would result from the ACS program. To respond to these concerns, the ACS and the American College of Radiology (ACR) established a joint committee on mammography screening in 1986. After much discussion, it was decided to use the ACR Diagnostic Practice Accreditation Program as a model for the development of a mammography accreditation program. However, some constraints were required in order to make the program meet the needs of the ACS. This voluntary, peer review program had to be timely and cost effective. It was determined that the best way to address these needs would be to conduct the program by mail. Finally, by placing emphasis on the educational nature of the program, it would provide an even greater opportunity for improving mammographic quality. The result of this effort was that, almost six years ago, in May 1987, the pilot study for the ACR Mammography Accreditation Program (MAP) began, and in August of that year, the first applications were received. In November 1987, the first 3-year accreditation certificates were awarded

  5. Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Kitahama, Hiroyuki

    1991-01-01

    The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area=0.91) was better than that on film-screen mammography (ROC area=0.88) (p<0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study. (author)

  6. [Stones crushing lives: victims and their widows in the marble industry in Itaoca (ES)].

    Science.gov (United States)

    Moulin, Maria das Graças Barbosa; Minayo-Gomez, Carlos

    2008-01-01

    This text based on an ethnographic survey presents the social impact on the families of victims of fatal work accidents in the ornamental stone industry in Itaoca, district of Cachoeiro de Itapemirim, Espírito Santo, Brazil. The following elements are analyzed: family culture; living with fatal accidents; experiences of family grief; the way the companies and the union deal with worker rights; material, symbolic, and emotional resources used by the families to face hardship caused by accidents. Authoritarian management appealing to masculinity and improvisation are factors that favor work accidents. The need to earn their living, the fact of valuing work as an attribute of honorableness and lack of options render the workers subject to domination. Most of the widows are highly religious and receive emotional, symbolic and material support from their families, the community and the union. There is a notable lack of concern and support for the families on the part of managers and public institutions. Advances in the organization of the union and improvement of the working conditions forced by the demands of export buyers have occurred recently.

  7. Organisational aspects of mammography screening in digital settings: First experiences of Luxembourg

    International Nuclear Information System (INIS)

    Shannoun, F.; Schanck, J. M.; Scharpantgen, A.; Wagnon, M. C.; Ben Daoud, M.; Back, C.

    2008-01-01

    Luxembourg has been conducting a breast cancer screening programme since 1992, like a large number of other European countries, as early detection and treatment of breast cancer have been proven to reduce mortality. The majority of these screening programmes are based on analogue X-ray technology and have optimised their organisation of transporting, archiving and reading with respect to films. Last decade is marked by enormous developments in digital mammography. Different technologies such as flat panel-, computed radiography- and scanning systems became available. Digital mammography is expected to have a major impact on quality and organisation of breast cancer screening programmes. Screening programmes are now faced with a huge challenge of incorporating the digital technology, including implementation of electronic image exchange, conception of new electronic work-flow, establishing adapted quality assurance programmes and training of radiologists and technical personnel. Initial experiences of the Luxembourg approach in organising digital mammography screening and its quality assurance are reported. (authors)

  8. Prospective study aiming to compare 2D mammography and tomosynthesis + synthesized mammography in terms of cancer detection and recall. From double reading of 2D mammography to single reading of tomosynthesis.

    Science.gov (United States)

    Romero Martín, Sara; Raya Povedano, Jose Luis; Cara García, María; Santos Romero, Ana Luz; Pedrosa Garriguet, Margarita; Álvarez Benito, Marina

    2018-06-01

    To evaluate tomosynthesis compared with 2D-mammography in cancer detection and recalls in a screening-programme, and assess performing synthesized instead of 2D, and compare double reading of 2D with single reading of tomosynthesis. Women (age 50-69 years) participating in the screening-programme were included. 2D-mammography and tomosynthesis were performed. There were four reading models: 2D-mammography (first); 2D-mammography (second); tomosynthesis + synthesized (third); tomosynthesis + synthesized + 2D (fourth reading). Paired double reading of 2D (first+second) and tomosynthesis (third+fourth) were analysed. In 16,067 participants, there were 98 cancers and 1,196 recalls. Comparing double reading of 2D with single reading of tomosynthesis, there was an increase of 12.6 % in cancer detection with the third reading (p= 0.043) and 6.9 % with the fourth reading (p=0.210), and a decrease in recalls of 40.5 % (ptomosynthesis. Single reading of tomosynthesis plus synthesized increased cancer detection and decreased recalls compared with double reading 2D. 2D did not improve results when added to tomosynthesis. • Tomosynthesis increases cancer detection and decreases recall rates versus 2D mammography. • Synthesized-mammography avoids performing 2D, showing higher cancer detection. • Single reading of tomosynthesis + synthesized is feasible as a new practice.

  9. Crushed-salt constitutive model update

    International Nuclear Information System (INIS)

    Callahan, G.D.; Loken, M.C.; Mellegard, K.D.; Hansen, F.D.

    1998-01-01

    Modifications to the constitutive model used to describe the deformation of crushed salt are presented in this report. Two mechanisms--dislocation creep and grain boundary diffusional pressure solutioning--defined previously but used separately are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. New creep consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant and southeastern New Mexico salt to determine material parameters for the constitutive model. Nonlinear least-squares model fitting to data from the shear consolidation tests and a combination of the shear and hydrostatic consolidation tests produced two sets of material parameter values for the model. The change in material parameter values from test group to test group indicates the empirical nature of the model but demonstrates improvement over earlier work with the previous models. Key improvements are the ability to capture lateral strain reversal and better resolve parameter values. To demonstrate the predictive capability of the model, each parameter value set was used to predict each of the tests in the database. Based on the fitting statistics and the ability of the model to predict the test data, the model appears to capture the creep consolidation behavior of crushed salt quite well

  10. Crushed-salt constitutive model update

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, G.D.; Loken, M.C.; Mellegard, K.D. [RE/SPEC Inc., Rapid City, SD (United States); Hansen, F.D. [Sandia National Labs., Albuquerque, NM (United States)

    1998-01-01

    Modifications to the constitutive model used to describe the deformation of crushed salt are presented in this report. Two mechanisms--dislocation creep and grain boundary diffusional pressure solutioning--defined previously but used separately are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. New creep consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant and southeastern New Mexico salt to determine material parameters for the constitutive model. Nonlinear least-squares model fitting to data from the shear consolidation tests and a combination of the shear and hydrostatic consolidation tests produced two sets of material parameter values for the model. The change in material parameter values from test group to test group indicates the empirical nature of the model but demonstrates improvement over earlier work with the previous models. Key improvements are the ability to capture lateral strain reversal and better resolve parameter values. To demonstrate the predictive capability of the model, each parameter value set was used to predict each of the tests in the database. Based on the fitting statistics and the ability of the model to predict the test data, the model appears to capture the creep consolidation behavior of crushed salt quite well.

  11. Contrast-enhanced spectral mammography: comparison with conventional mammography and histopathology in 152 women.

    Science.gov (United States)

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p mammography.

  12. Teaching atlas of mammography

    International Nuclear Information System (INIS)

    Tabar, L.; Dean, P.B.

    1985-01-01

    The illustrated case reports in this teaching atlas cover practically the entire range of possible pathological changes and are based on in-patient case material and 80,000 screening documents. The two basic approaches, - detection and analysis of changes -, are taught comprehensively and in great detail. A systematic procedure for analysing the mammographies, in order to detect even the very least changes, and its practical application is explained using mammographies showing unclear findings at first sight. A system of coordinates is presented which allows precise localisation of the changes. Exercises for practising the technique of identifying the pathological changes round up the methodolical chapters. Additional imaging technical enhancements and detail enlargements are of great help in interpreting the findings. The specific approach adopted for this teaching atlas is a 'reverse procedure', which leaves the beaten track and starts with analysing the mammographies and evaluating the radiographic findings, in order to finally derive the diagnosis. (orig./CB) [de

  13. A comparative study of pulmonary Koch's among marble stone worker community of Bhedaghat and nonmarble stone worker community of Garha

    OpenAIRE

    Shashi Prabha Tomar; Avadhesh PS Kushwah; Sonjjoay Pande; Pushpraj S Baghel

    2014-01-01

    Introduction: Occupational stone dust exposure may result in several health risks tuberculosis (TB) silicosis, obstructive as well as restrictive lung diseases, among which TB is more prevalent in developing countries like India. Most people residing in Bhedaghat engaged in carving statues from variable stones and marble rocks belongs to poor socioeconomic conditions and unaware of the preventive measures. Ultimately they end up in chronic respiratory problems and various complications. Objec...

  14. Mammography in women under 35

    International Nuclear Information System (INIS)

    Panzarola, P.; Bellucci, M.C.

    1991-01-01

    The detection of breast cancer in women under 35 is quite an uncommon event, accounting only for 3.2-3.4% of all breast cancers. To determine the indications for mammography in women under 35, the authors correlated clinical, mammographic, and US findings with fine-needle aspiration/surgical biopsy and follow-up results in 1040 symptomatic women examined at the Center of Senology of the Istitute of Radiology - University of Perugia, Italy, from 1984 to June 1990. Of 1040 women, 482 (41.6%) had normal findings; benign disease was diagnosed in 558 (53.7%) cases, and malignant disease in 49 (4.7%). Mammography was very useful to diagnose malignancy in palpable breast lesions, as well as to suggest the need for biopsy, to detect metachronous cancer and to define lesion sizes. In inflammatory process - e.g., mastitis and abscesses - both mammography and US were capable as its remission after therapy. Galactography had a specific role in the evaluation of the mammary duct and demonstrated intraductal pathologic conditions. In the authors'experiences, mammography never showed occult breast cancers in women with no palpable breast lesions or hematic nipple discharge

  15. UV Ink-Jet printability and durability of stone and foil

    Directory of Open Access Journals (Sweden)

    Tadeja Muck

    2014-07-01

    Full Text Available he use of ultraviolet (UV printing technology has impacted printing industry in last years due to its applicability on many different »absorptive« as well as »non-absorptive« printing materials. The printability of building materials and recycled foils is relatively unknown. For primary building materials like stones, functionality can be explored with the use of UV printing technology; increased visual, informative effect or even “creative printing” of buildings. Also several aspects of recycled foils reusability as a printing material could be find (printed packaging material or also like secondary building materials. In the present study, printability of the stone and recycled foil and durability of UV prints was explored by means of macroscopically and microscopically characterization. Results indicate that higher print quality can be achieved on polished stone and on coated foil, which surfaces have higher smoothness. Durability of UV prints at freezing is higher at unpolished stone and coated foil that is at materials with the higher surface energy.

  16. Open stone surgery: a still-in-use approach for complex stone burden.

    Science.gov (United States)

    Çakici, Özer Ural; Ener, Kemal; Keske, Murat; Altinova, Serkan; Canda, Abdullah Erdem; Aldemir, Mustafa; Ardicoglu, Arslan

    2017-06-30

    Urinary stone disease is a major urological condition. Endourologic techniques have influenced the clinical approach and outcomes. Open surgery holds a historic importance in the management of most conditions. However, complex kidney stone burden may be amenable to successful results with open stone surgery. In this article, we report our eighteen cases of complex urinary stone disease who underwent open stone removal. A total of 1701 patients have undergone surgical treatment for urinary stone disease in our clinic between July 2012 and July 2016, comprising eighteen patients who underwent open stone surgery. Patients' demographic data, stone analysis results, postoperative clinical data, and stone status were evaluated retrospectively. The choice of surgical approach is mostly dependent on the surgeon's preference. In two patients, open surgery was undertaken because of perioperative complications. We did not observe any Clavien-Dindo grade 4 or 5 complications. Three patients were managed with a course of antibiotics due to postoperative fever. One patient had postoperative pleurisy, one patient had urinoma, and two patients had postoperative ileus. Mean operation time was 84 (57-124) minutes and mean hospitalization time was 5.5 (3-8) days. Stone-free status was achieved in 15 patients (83.3%). Endourologic approaches are the first options for treatment of urinary stone disease. However, open stone surgery holds its indispensable position in complicated cases and in complex stone burden. Open stone surgery is also a valid alternative to endourologic techniques in all situations.

  17. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    OpenAIRE

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    Objective The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. Materials and Methods The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body...

  18. Dynamic Response and Residual Helmet Liner Crush Using Cadaver Heads and Standard Headforms.

    Science.gov (United States)

    Bonin, S J; Luck, J F; Bass, C R; Gardiner, J C; Onar-Thomas, A; Asfour, S S; Siegmund, G P

    2017-03-01

    Biomechanical headforms are used for helmet certification testing and reconstructing helmeted head impacts; however, their biofidelity and direct applicability to human head and helmet responses remain unclear. Dynamic responses of cadaver heads and three headforms and residual foam liner deformations were compared during motorcycle helmet impacts. Instrumented, helmeted heads/headforms were dropped onto the forehead region against an instrumented flat anvil at 75, 150, and 195 J. Helmets were CT scanned to quantify maximum liner crush depth and crush volume. General linear models were used to quantify the effect of head type and impact energy on linear acceleration, head injury criterion (HIC), force, maximum liner crush depth, and liner crush volume and regression models were used to quantify the relationship between acceleration and both maximum crush depth and crush volume. The cadaver heads generated larger peak accelerations than all three headforms, larger HICs than the International Organization for Standardization (ISO), larger forces than the Hybrid III and ISO, larger maximum crush depth than the ISO, and larger crush volumes than the DOT. These significant differences between the cadaver heads and headforms need to be accounted for when attempting to estimate an impact exposure using a helmet's residual crush depth or volume.

  19. Digital mammography in breast cancer screening: Evaluation and innovation

    NARCIS (Netherlands)

    Bluekens, A.M.J.

    2015-01-01

    With all other imaging modalities in radiology being digitised and conventional mammography being ready to phase out the transition to digital mammography was inevitable. This thesis describes the performance of digital screening mammography and the consequences of implementation in a

  20. CONTRAST ENHANCED SPECTRAL MAMMOGRAPHY (CESM (REVIEW

    Directory of Open Access Journals (Sweden)

    N. I. Rozhkova

    2015-01-01

    Full Text Available The problem of early diagnosis of a breast cancer is extremely actual. Growth of incidence at women from 19 to 39 years increased for 34% over the last 10 years. It defines need of acceleration of development and deployment of the latest technologies of identification of the earliest symptoms of diseases. The x-ray mammography is the conducting method among of all radiological methods of diagnostics. Nevertheless a number of restrictions of method reduces its efficiency. The technologies increasing informational content of x-ray mammography – the leading method of screening – due to use of artificial contrasting and advantages of digital technologies are constantly developed. In this review it is described works, in which the authors having clinical experience of application of CESM – contrastenhanced spectral mammography on representative group of women. Positive sides and restrictions of new technology in comparison with mammography, ultrasonography and MRT are shown in this article.

  1. Heavy-ion mammography and breast cancer

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Capp, M.P.; Holley, W.R.; Woodruff, K.H.; Sickles, E.A.

    1980-01-01

    Heavy-ion radiography is a new diagnostic imaging technique developed in our laboratory that produces superior density resolution at low radiation doses. Heavy-ion mammography has now emerged as a low-dose, safe, reliable, noninvasive diagnostic radiological procedure that can quantitate and image very small differences in soft tissue densities in the breast tissues of patients with clinical breast disease. The improved density resolution of heavy-ion mammography over conventional X-ray mammography and breast xerography provides the potential of detecting small breast cancers of less than 1 cm diameter. The radiation dose to the breast from carbon-ion mammorgraphy is about 50 mrad or less, and can potentially be only a fraction of this level. The results of the present clinical trial in progress of heavy-ion mammography in 37 patients, thus far studied, are extremely encouraging, and warrant continued study for application to the early diagnosis of breast cancer in women

  2. Constitutive behavior of reconsolidating crushed salt

    International Nuclear Information System (INIS)

    Callahan, G.D.; Mellegard, K.D.; Hansen, F.D.

    1998-02-01

    The constitutive model used to describe deformation of crushed salt is presented in this paper. Two mechanisms--dislocation creep and grain boundary diffusional pressure solutioning--are combined to form the basis for the constitutive model governing deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Recently completed creep consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant (WIPP) and southeastern New Mexico salt to determine material parameters for the constitutive model. Nonlinear least-squares model fitting to data from shear consolidation tests and a combination of shear and hydrostatic tests produces two sets of material parameter values for the model. Changes in material parameter values from test group to test group indicate the empirical nature of the model but show significant improvement over earlier work. To demonstrate the predictive capability of the model, each parameter value set was used to predict each of the tests in the database. Based on fitting statistics and ability of the model to predict test data, the model appears to capture the creep consolidation behavior of crushed salt quite well

  3. Radiation hazards of X-ray mammography

    International Nuclear Information System (INIS)

    Bailar, J.C. III

    1978-01-01

    X-ray mammography delivers significant amounts of ionizing radiation to the breast, and the female breast is more susceptible to radiation carcinogenesis than any other human organ. On the other hand, breast cancer is least likely to cause serious illness and death when it is detected at a very early stage. The risks and benefits of mammography can be estimated. This paper summarizes current risk estimates, then proceeds to a comparison of risks and benefits. As for breast cancer mortality, the addition of mammography to a programme of annual breast examinations of average U.S. women is of questionable value for women under age 50 but it is probably beneficial for older women. However, the break-even point is closely related to the average radiation exposure of breast tissue, and would be earlier in a few centres now using optimum techniques and equipment. For women with below-average risks of breast cancer, the age would be higher, and for a few women with a high probability of developing breast cancer it would be lower. Breast cancer screening programmes have been improved significantly since criticisms were first publicized in mid-1975. Partial improvements include reduction in radiation exposure (at least in some centres), guidelines from the National Cancer Institute (NCI) and the American Cancer Society (ACS) for restricting the screening of women under age 50, and changes in the patient consent form signed by participants in the NCI-ACS programme. Professional and public awareness of the need to balance the benefits of screening with its risks and costs has rapidly and markedly increased. Future improvements should further define the optimum design and application of breast cancer screening programmes

  4. Atténuation des risques pour la santé dans le secteur de l'extraction ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Abstract for oral presentation : addressing health risk of communities residing close to stone quarrying and crushing unit using ecohealth framework in Central India. Reports. Assessing and mitigating health risks from stone quarrying and crushing industry in Bundelkhand region of Central India : final technical report, ...

  5. Evaluating the Psychological Concomitants of Other-Sex Crush Experiences during Early Adolescence

    Science.gov (United States)

    Bowker, Julie C.; Etkin, Rebecca G.

    2016-01-01

    Very little empirical attention has been paid to other-sex crush experiences during adolescence. As a result, it is not known whether such experiences, which appear to be relatively common, impact psychological adjustment outcomes. This two-wave (3 month interval) longitudinal study of 268 young adolescents (48% girls; M age at Time 1 = 11.84 years) examined the psychological concomitants of other-sex crush experiences (having and being viewed by others as a crush). Anxious-withdrawal and gender were evaluated as moderators. Peer nomination measures at Time 1 assessed both types of crush experiences and mutual friendship involvement, and participants completed self-report measures of loneliness and depressive symptoms at Times 1 and 2. The results from regression analyses revealed significant associations between having an other-sex crush and depressive symptoms at Time 1, after accounting for the effects of mutual friendship. Two interaction effects also revealed that crush status was a risk factor for depressive symptoms at low levels of anxious-withdrawal but a protective factor at high levels. The findings provide the first empirical evidence that other-sex crush experiences are developmentally significant during early adolescence. PMID:26984754

  6. A novel stone retrieval basket for more efficient lithotripsy procedures.

    Science.gov (United States)

    Salimi, N; Mahajan, A; Don, J; Schwartz, B

    2009-01-01

    This paper presents the development of an improved stone retrieval device that uses a newly designed cage of Nitinol wires encompassing a mesh basket made of a material that is laser resistant. Current methods to extract large stones involve imaging, using a laser to fragment the stones and then using existing cage-like baskets to trap the fragments individually and extracting them one at a time. These procedures are tedious, and may result in leaving some fragments behind that can reform causing the need for another procedure. The device presented in this paper will have a mesh-like sack which will consist of a laser resistant material of polytetrafluoroethylene (PTFE) enclosed within a newly designed Nitinol cage. Two alternate designs are provided for the cage in this paper. The handle of the device is revised to allow for a 3 Fr (1 mm) opening such that a laser's fiber optic cable can enter the device. Using this device a laser can be used to fragment the stone, and all the fragments are retained in the basket in both the design options. The basket can then be retracted allowing for the retrieval of all the fragments in one shot. The stone retrieval basket presented in this paper will significantly improve the efficiency and effectiveness of lithotripsy procedures for removal of large kidney and biliary tract stones.

  7. Pain and discomfort during mammography

    DEFF Research Database (Denmark)

    Aro, A R; Absetz-Ylöstalo, P; Eerola, T

    1996-01-01

    was the most powerful factor explaining pain and discomfort among women with earlier mammography. However, it had no effect among women without earlier mammography, for whom screening-related nervousness and perceptions of staff were crucial. Suggested interventions include better information before screening......The aim of this prospective study was to investigate associations of mammography pain and discomfort with sociodemographics, personal history and psychological and situational factors. Subjects were women with a negative screening finding (n = 883) from a random sample of 50-year-old Finnish women...... attending their first breast cancer screening. Questionnaires were sent 1 month before the screening invitation and 2 months after screening. Sixty-one per cent reported painful and 59% uncomfortable mammograms (4% severely). Linear regression analyses showed that anticipation of pain and discomfort...

  8. Mammography quality assurance in Morocco

    International Nuclear Information System (INIS)

    Zaoui, F.; Talsmat, K.; Lalaoui, K.

    2001-01-01

    The 'Centre National de l'Energie, des Sciences et des Techniques Nucleaires' (CNESTEN) realised, from February 1999 to March 2000, a quality control of 41 mammography facilities in Morocco. The protocol and standards adopted for achieving the control of elements constituting the mammography chain are those elaborated by GIM and Qualix association. Statistics and conformities results are presented. The program was performed in order to demonstrate to the practitioners in mammography field, the utility and necessity to have a national quality assurance policy. The main objective of CNESTEN is to be accredited by the Moroccan government as a reference laboratory in quality control and dose evaluation in medical imaging and radiotherapy. To achieve this goal the CNESTEN has set up Medical Physic Unit well trained and equipped with the necessary instruments. (author)

  9. Breast cancer screening using tomosynthesis in combination with digital mammography.

    Science.gov (United States)

    Friedewald, Sarah M; Rafferty, Elizabeth A; Rose, Stephen L; Durand, Melissa A; Plecha, Donna M; Greenberg, Julianne S; Hayes, Mary K; Copit, Debra S; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Miller, Dave P; Conant, Emily F

    2014-06-25

    Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. A total of 454,850 examinations (n=281,187 digital mammography; n=173,663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29,726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15,541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P tomosynthesis was associated with an increase

  10. Contribution of stone size to chronic kidney disease in kidney stone formers.

    Science.gov (United States)

    Ahmadi, Farrokhlagha; Etemadi, Samira Motedayen; Lessan-Pezeshki, Mahbob; Mahdavi-Mazdeh, Mitra; Ayati, Mohsen; Mir, Alireza; Yazdi, Hadi Rokni

    2015-01-01

    To determine whether stone burden correlates with the degree of chronic kidney disease in kidney stone formers. A total of 97 extracorporeal shockwave lithotripsy candidates aged 18 years and older were included. Size, number and location of the kidney stones, along with cumulative stone size, defined as the sum of diameters of all stones) were determined. Estimated glomerular filtration rate was determined using the Chronic Kidney Disease Epidemiology Collaboration cystatin C/creatinine equation, and chronic kidney disease was defined as estimated glomerular filtration rate chronic kidney disease. The relationship persisted even after adjustment for age, sex, body mass index, C-reactive protein, fasting plasma glucose, thyroid stimulating hormone, presence of microalbuminuria, history of renal calculi, history of extracorporeal shockwave lithotripsy, number and location of the stones (odds ratio 1.24, 95% confidence interval 1.02-1.52). The same was not observed for individuals with a cumulative stone size ≥ 20 mm. In kidney stone formers with a cumulative stone size up to 20 mm, estimated glomerular filtration rate linearly declines with increasing cumulative stone size. Additionally, cumulative stone size is an independent predictor of chronic kidney disease in this group of patients. © 2014 The Japanese Urological Association.

  11. TL dosimetry for quality control of CR mammography imaging systems

    Science.gov (United States)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  12. Continuous-flow leaching studies of crushed and cored SYNROC

    International Nuclear Information System (INIS)

    Coles, D.G.; Bazan, F.

    1980-01-01

    Both crushed (150 to 300 μm) and cored 1.8 mm diameter) samples of SYNROC have been leached with the single-pass continuous-flow leaching equipment. Crushed samples of Cs-hollandite were also leached in a similar experiment. Temperatures used were 25 0 C and 75 0 C and leachates were 0.03 N NaHCO 3 and distilled water. Leaching rates from SYNROC C were ranked Cs > Sr greater than or equal to Ca > Ba > Zr. A comparison of leaching rates is made between crushed SYNROC, cored SYNROC, and PNL 76-68 glass beads. Problems encountered when comparing the leaching rates of different waste forms are discussed

  13. Radiogenic breast cancer risk and mammography

    International Nuclear Information System (INIS)

    Jayaprakash, Shobha; Nair, C.P.R.; Rao, B.S.; Sawant, S.G.

    2001-01-01

    There is a general concern that the risks from mammography screening in inducting radiogenic breast cancer may outweigh the possible benefits to be derived from it. A review of epidemiological, case-control and cohort studies of radiogenic breast cancer, age-specific incidence and dose and dose-rate relationship reveals that such a fear is unfounded. The dose to the breast tissues in a quality assured mammography screening programme falls far below the levels that were observed to produce increased relative risk. The age-specific incidence rates also indicate that the need for mammography is for the women of age at which the relative risk is minimum

  14. Bath Stone - a Possible Global Heritage Stone from England

    Science.gov (United States)

    Marker, Brian

    2014-05-01

    The Middle Jurassic strata of England have several horizons of oolitic and bioclastic limestones that provide high quality dimension stone. One of the most important is found in and near the City of Bath. The Great Oolite Group (Upper Bathonian) contains the Combe Down and Bath Oolites, consisting of current bedded oolites and shelly oolites, that have been used extensively as freestones for construction nearby, for prestigious buildings through much of southern England and more widely. The stone has been used to some extent since Roman times when the city, then known as Aquae Sulis, was an important hot spa. The stone was used to a limited extent through medieval times but from the early 18th century onwards was exploited on a large scale through surface quarrying and underground mining. The City was extensively redeveloped in the 18th to early 19th century, mostly using Bath Stone, when the spas made it a fashionable resort. Buildings from that period include architectural "gems" such as the Royal Crescent and Pulteney Bridge, as well as the renovated Roman Baths. Many buildings were designed by some of the foremost British architects of the time. The consistent use of this stone gives the City an architectural integrity throughout. These features led to the designation of the City as a World Heritage Site. It is a requirement in current City planning policy documents that Bath Stone should be used for new building to preserve the appearance of the City. More widely the stone was used in major houses (e.g. Buckingham Palace and Apsley House in London; King's Pavilion in Brighton); civic buildings (e.g. Bristol Guildhall; Dartmouth Naval College in Devon); churches and cathedrals (e.g. Truro Cathedral in Cornwall); and engineered structures (e.g. the large Dundas Aqueduct on the Kennet and Avon Canal). More widely, Bath Stone has been used in Union Station in Washington DC; Toronto Bible College and the Town Hall at Cape Town, South Africa. Extraction declined in

  15. Fractal and Morphological Characteristics of Single Marble Particle Crushing in Uniaxial Compression Tests

    Directory of Open Access Journals (Sweden)

    Yidong Wang

    2015-01-01

    Full Text Available Crushing of rock particles is a phenomenon commonly encountered in geotechnical engineering practice. It is however difficult to study the crushing of rock particles using classical theory because the physical structure of the particles is complex and irregular. This paper aims at evaluating fractal and morphological characteristics of single rock particle. A large number of particle crushing tests are conducted on single rock particle. The force-displacement curves and the particle size distributions (PSD of crushed particles are analysed based on particle crushing tests. Particle shape plays an important role in both the micro- and macroscale responses of a granular assembly. The PSD of an assortment of rocks are analysed by fractal methods, and the fractal dimension is obtained. A theoretical formula for particle crushing strength is derived, utilising the fractal model, and a simple method is proposed for predicting the probability of particle survival based on the Weibull statistics. Based on a few physical assumptions, simple equations are derived for determining particle crushing energy. The results of applying these equations are tested against the actual experimental data and prove to be very consistent. Fractal theory is therefore applicable for analysis of particle crushing.

  16. Efficacy of the lithotripsy in treating lower pole renal stones.

    Science.gov (United States)

    Cui, Helen; Thomee, Eeke; Noble, Jeremy G; Reynard, John M; Turney, Benjamin W

    2013-06-01

    Use of extracorporeal lithotripsy is declining in North America and many European countries despite international guidelines advocating it as a first-line therapy. Traditionally, lithotripsy is thought to have poor efficacy at treating lower pole renal stones. We evaluated the success rates of lithotripsy for lower pole renal stones in our unit. 50 patients with lower pole kidney stones ≤15 mm treated between 3/5/11 and 19/4/12 were included in the study. Patients received lithotripsy on a fixed-site Storz Modulith SLX F2 lithotripter according to a standard protocol. Clinical success was defined as stone-free status or asymptomatic clinically insignificant residual fragments (CIRFs) ≤3 mm at radiological follow-up. The mean stone size was 7.8 mm. The majority of stones (66 %) were between 5 and 10 mm. 28 % of stones were between 10 and 15 mm. For solitary lower pole stones complete stone clearance was achieved in 63 %. Total stone clearance including those with CIRFs was achieved in 81 % of patients. As expected, for those with multiple lower pole stones the success rates were lower: complete clearance was observed in 39 % and combined clearance including those with CIRFs was 56 %. Overall, complete stone clearance was observed in 54 % of patients and clearance with CIRFs was achieved in 72 % of patients. Success rate could not be attributed to age, stone size or gender. Our outcome data for the treatment of lower pole renal stones (≤15 mm) compare favourably with the literature. With this level of stone clearance, a non-invasive, outpatient-based treatment like lithotripsy should remain the first-line treatment option for lower pole stones. Ureteroscopy must prove that it is significantly better either in terms of clinical outcome or patient satisfaction to justify replacing lithotripsy.

  17. A study of some technical essentials of X-ray mammography

    International Nuclear Information System (INIS)

    Cao Houde; Jiang Qin

    2000-01-01

    Objective: To improve the quality of mammography and diagnostic accuracy by analyzing and studying some of the technical essentials of X-ray mammography. Methods: The mammography quality of 21 hospitals were investigated. The image quality of normal intensifying screen-film combination was tested and compared with computerized mammography. The filming positions and operating skills were studied. Results: The important mammography details that were displayed have low conformity with the diagnostic requirements, mainly due to non-conformity of these equipment to the requirements. The optimal pressure suitable for mammography of the Chinese women was around 12 kg. Conclusion: Necessary attention must be paid to the improvement of imaging features of these equipment. The improved operating skills will greatly raise the detecting percentage of pathological changes of breasts

  18. Search Results | Page 44 | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Results 431 - 439 of 439 ... Mitigating the Health Risks of Stone Quarrying and Crushing in India. In Pratapura Industrial Area (Tikamgarh district, Bundelkhand region, Madhya Pradesh), stone quarrying and crushing is carried out by labor-intensive units employing unskilled workers on a seasonal basis complementing the ...

  19. Average glandular dose in routine mammography screening using a Sectra Microdose Mammography unit

    International Nuclear Information System (INIS)

    Hemdal, B.; Herrnsdorf, L.; Andersson, I.; Bengtsson, G.; Heddson, B.; Olsson, M.

    2005-01-01

    The Sectra MicroDose Mammography system is based on direct photon counting (with a solid-state detector), and a substantially lower dose to the breast than when using conventional system can be expected. In this work absorbed dose measurements have been performed for the first unit used in routine mammography screening (at the Hospitals of Helsingborg (Sweden)). Two European protocols on dosimetry in mammography have been followed. Measurement of half value layer (HVL) cannot be performed as prescribed, but this study has demonstrated than non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated solid-state detector with simultaneous correction for the energy dependence. The average glandular dose for a 50 mm standard breast with 50% glandularity, simulated by 45 mm polymethylmethacrylate, was found to be 0.21 and 0.28 mGy in March and December 2004, respectively. These values are much lower than for any other mammography system on the market today. It has to be stressed that the measurement were made using the current clinical settings and that no systematic optimisation of the relationship between absorbed dose and diagnostic image quality has been performed within the present study. In order to further increase the accuracy of absorbed dose measurements for this unit, the existing dose protocols should be revised to account also for the tungsten/aluminium anode/filter combination, the multi-slit pre-collimator device and the occurrence of a dose profile in the scanning direction. (authors)

  20. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    Energy Technology Data Exchange (ETDEWEB)

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia [Department of Radiology, Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Krakow 31-115 (Poland); Blecharz, Pawel [Department of Gynecologic Oncology, Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Krakow 31-115 (Poland); Rys, Janusz [Department of Tumour Pathology, Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Krakow 31-115 (Poland); Reinfuss, Marian [Department of Radiotherapy, Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Krakow 31-115 (Poland)

    2014-07-01

    The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an 'iodine' image which outlined contrast up-take in the breast. MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography.

  1. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    International Nuclear Information System (INIS)

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an 'iodine' image which outlined contrast up-take in the breast. MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography

  2. Radionuclide sorption on crushed and intact granitic rock

    International Nuclear Information System (INIS)

    Eriksen, Tryggve E.; Locklund, Birgitta

    1989-05-01

    The specific surface areas and distribution ratios for sorption of 85 Sr, 137 Cs and 152 Eu were measured for crushed and intact granite rock. The experimental data can be accommodated by a sorption model encompassing sorption on outer and inner surface. It is clearly demonstrated that the time required to obtain reliable Kd-values for the sorption of strongly sorbing radionuclides like 152 Eu is very long due to solution depletion and slow diffusion into the rock. A combination of surface area measurements and batch sorption with small particles may therefore be preferable when studying strongly sorbing nuclides. (authors) (17 figs., 6 tabs.)

  3. Quality control in digital mammography: the noise components

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando [Universidade de Tarapaca, Arica (Chile). Centro de Estudios en Ciencias Radiologicas; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Duran, Maria Paz [Clinica Alemana, Santiago (Chile). Dept. de Radiologia; Dantas, Marcelino, E-mail: marcelino@inb.gov.b [Industrias Nucleares do Brasil (INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Ubeda, Carlos, E-mail: cubeda@uta.c [Universidade de Tarapaca, Arica (Chile). Fac. de Ciencias de la Salud

    2011-07-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  4. Quality control in digital mammography: the noise components

    International Nuclear Information System (INIS)

    Leyton, Fernando; Nogueira, Maria do Socorro; Duran, Maria Paz; Dantas, Marcelino; Ubeda, Carlos

    2011-01-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  5. Implementation of Quality Control Protocol in Mammography: A Serbian Experience

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Kosutic, D.; Arandjic, D.; Kovacevic, M.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. In Serbia, mammography is performed only clinically, although there is a long term plan to introduce mammography as screening method. Currently there are 60 mammography units in practice in Serbia, resulting with 70 000 mammographies annually. The purpose of this paper is preliminary evaluation of the mammography practice in Serbia, having in mind the annual number of examinations and fact that part of examination is performed on women without any clinical signs. For pilot implementation of Quality Control (QC) protocol in mammography, five hospitals with highest workload have been selected, representing the typical mammography practice in Serbia. Developed QC protocol, based on European guidelines for quality assurance in breast cancer screening and diagnosis, actual practice and resources, includes equipment testing and maintenance, staff training and QC management and allocation of responsibilities. Subsequently, it should be applied on the national scale. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Main problems were associated with film processing, viewing conditions and optical density control. The preliminary survey of mammography practice highlighted the need for optimization of radiation protection and training of operating staff, although the survey itself was very valuable learning process for all participants. Furthermore, systematic implementation of QC protocol should provide reliable performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practical.(author)

  6. Mammography use among women aged 18-39 years in the United States.

    Science.gov (United States)

    Qin, Jin; White, Mary C; Sabatino, Susan A; Febo-Vázquez, Isaedmarie

    2018-04-01

    Recommendations for breast cancer screening using mammography target asymptomatic women aged ≥ 40 years who are not at increased risk for breast cancer. Evidence is not available to demonstrate benefits of screening with mammography at younger ages, and little is known about mammography use among younger women. This study described mammography use among women aged 18-39 years. We analyzed data from the 2011-2015 National Survey of Family Growth, an in-person survey of a nationally representative sample of the U.S. household population. We estimated the prevalence of ever receiving a mammogram and examined reasons for the first mammograms among women aged 18-39 years without personal cancer history (n = 8324). We classified the first mammogram as a screening examination if it was performed either as part of a routine exam or because of family history of cancer. Among women aged 18-39 years, 14.3% (95% CI 13.2-15.4) reported ever having a mammogram. Prevalence of mammography use was highest among women aged 35-39 years (31.0%, 95% CI 27.8-34.5), and was higher among non-Hispanic black women than in other race/ethnicity groups. Women with a family history of breast cancer reported a higher prevalence of mammography use than women without this family history. For both women with and without a family history of breast cancer, about half of all first mammograms were performed for screening reasons. Among U.S. women aged 18-39 years with no personal cancer history, one in seven reported having received a mammogram. Women with no family history of breast cancer were as likely as those with a family history to initiate breast cancer screening with mammography before age 40. Our findings provide evidence that supports further research to examine factors that prompt young women to receive screening mammograms.

  7. Gas adsorption on crushed quartz and basalt. [in vacuum

    Science.gov (United States)

    Barker, C.; Torkelson, B. E.

    1975-01-01

    The new surfaces generated by crushing rocks and minerals adsorb gases. Different gases are adsorbed to different extents so that both the total amount and composition of the released gases are changed. This affects the interpretation of the composition of the gases obtained by vacuum crushing lunar basalts, meteorites and minerals with fluid inclusions.

  8. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  9. Crushing Strength of Ship Structures

    DEFF Research Database (Denmark)

    Cerup-Simonsen, Bo; Abramowicz, W.; Høstgaard-Brene, C.N.S.

    1999-01-01

    The crushing response of ship structures is of primary importance to the designers and practicing engineers concerned with accidental loading and accident reconstruction of marine vehicles. Ship to-ship collisions, ship-harbor infrastructure interaction or ship-offshore structure interaction are ...

  10. Crushing strength of HTGR fuel particles

    International Nuclear Information System (INIS)

    Lackey, W.J.; Stinton, D.P.; Davis, L.E.; Beatty, R.L.

    1976-01-01

    The whole-particle crushing strengths of High-Temperature Gas-Cooled Reactor fertile and fissile coated particles were measured and correlated with fabrication procedures. The crushing strength of Biso-coated fertile particles was increased by the following factors: (1) increasing the outer coating thickness by 10 μm increased strengths by 0.3 lb (1.3 N) for annealed particles and by 0.5 lb (2.2 N) for unannealed particles. (2) An 1800 0 C postcoating anneal increased strengths by 1 lb (4.4 N) for particles with thick outer coatings and by 2 lb (8.9 N) for particles having thin coatings. (3) Increasing the inner coating density by 0.1 g/cm 3 increased strength by 0.6 lb (2.7 N). The crushing strength of Triso-coated fissile particles was proportional to the thickness of the SiC coatings, and strength decreased on annealing by about 0.2 lb (0.9 N) when a porous plate was used to distribute the coating gas and by about 1.5 lb (6.7 N) when a conical gas distributor was used. The strengths of fertile and fissile coated particles as well as uncoated kernels appear adequate to allow fuel fabrication without excessive particle damage

  11. The Swedish Bohus granite - a stone with a fascinating history

    Science.gov (United States)

    Schouenborg, Björn; Eliasson, Thomas

    2015-04-01

    blocks but also paving products like sets, slabs and kerb stones are still manufactured in Sweden. Blocks are generally further processed in other countries like Italy and China to reach the European market as semi-finished products like slabs or finished products for any kind of application. The granite is very durable and suitable for all types of natural stone products.

  12. Impacted Anterior Urethral Calculus Complicated by a Stone-containing Diverticulum in an Elderly Man: Outcome of Transurethral Lithotripsy without Resection of the Diverticulum

    Directory of Open Access Journals (Sweden)

    Tie Zhou

    2013-09-01

    Full Text Available Introduction The prevalence of lower urinary tract symptoms (LUTS is about 20% in men aged 40 or above. Other than benign prostatic hyperplasia (BPH, urethral diverticulum or calculus is not uncommon for LUTS in men. Surgical treatment is often recommended for urethral diverticulum or calculus, but treatment for an impacted urethral calculus complicated by a stone-containing diverticulum is challenging. Materials and Methods An 82-year-old man had the persistence of LUTS despite having undergone transurethral resection of prostate for BPH. Regardless of treatment with broad spectrum antibiotics and an α-blocker, LUTS and post-void residual urine volume (100 mL did not improve although repeated urinalysis showed reduction of WBCs from 100 to 10 per high power field. Further radiology revealed multiple urethral calculi and the stone configuration suggested the existence of a diverticulum. He was successfully treated without resecting the urethral diverticulum; and a new generation of ultrasound lithotripsy (EMS, Nyon, Switzerland through a 22F offset rigid Storz nephroscope (Karl Storz, Tuttingen, Germany was used to fragment the stones. Results The operative time was 30 minutes and the stones were cleanly removed. The patient was discharged after 48 hours with no immediate complications and free of LUTS during a 2 years follow-up. Conclusions When the diverticulum is the result of a dilatation behind a calculus, removal of the calculus is all that is necessary. Compared with open surgery, ultrasound lithotripsy is less invasive with little harm to urethral mucosa; and more efficient as it absorbs stone fragments while crushing stones.

  13. Impacted anterior urethral calculus complicated by a stone-containing diverticulum in an elderly man: outcome of transurethral lithotripsy without resection of the diverticulum.

    Science.gov (United States)

    Zhou, Tie; Chen, Guanghua; Zhang, Wei; Peng, Yonghan; Xiao, Liang; Xu, Chuangliang; Sun, Yinghao

    2013-01-01

    The prevalence of lower urinary tract symptoms (LUTS) is about 20% in men aged 40 or above. Other than benign prostatic hyperplasia (BPH), urethral diverticulum or calculus is not uncommon for LUTS in men. Surgical treatment is often recommended for urethral diverticulum or calculus, but treatment for an impacted urethral calculus complicated by a stone-containing diverticulum is challenging. An 82-year-old man had the persistence of LUTS despite having undergone transurethral resection of prostate for BPH. Regardless of treatment with broad spectrum antibiotics and an α-blocker, LUTS and post-void residual urine volume (100 mL) did not improve although repeated urinalysis showed reduction of WBCs from 100 to 10 per high power field. Further radiology revealed multiple urethral calculi and the stone configuration suggested the existence of a diverticulum. He was successfully treated without resecting the urethral diverticulum; and a new generation of ultrasound lithotripsy (EMS, Nyon, Switzerland) through a 22F offset rigid Storz nephroscope (Karl Storz, Tuttingen, Germany) was used to fragment the stones. The operative time was 30 minutes and the stones were cleanly removed. The patient was discharged after 48 hours with no immediate complications and free of LUTS during a 2 years follow-up. When the diverticulum is the result of a dilatation behind a calculus, removal of the calculus is all that is necessary. Compared with open surgery, ultrasound lithotripsy is less invasive with little harm to urethral mucosa; and more efficient as it absorbs stone fragments while crushing stones.

  14. Mammography calibration qualities establishment in a Mo-Mo clinical system

    International Nuclear Information System (INIS)

    Correa, E.L.; Santos, L.R. dos; Vivolo, V.; Potiens, M.P.A.

    2015-01-01

    In this study the mammography calibration qualities were established in a clinical mammography system. The objective is to provide the IPEN instruments calibration laboratory with both mammography calibration methods (using a clinical and an industrial system). The results showed a good behavior of mammography equipment, in terms of kVp, PPV and exposure time. The additional filtration of molybdenum is adequate, air-kerma rates were determined and spectra were obtained. (author)

  15. Mammography calibration qualities establishment in a Mo-Mo clinical system

    Energy Technology Data Exchange (ETDEWEB)

    Correa, E.L.; Santos, L.R. dos; Vivolo, V.; Potiens, M.P.A., E-mail: educorrea1905@gmail.com [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    In this study the mammography calibration qualities were established in a clinical mammography system. The objective is to provide the IPEN instruments calibration laboratory with both mammography calibration methods (using a clinical and an industrial system). The results showed a good behavior of mammography equipment, in terms of kVp, PPV and exposure time. The additional filtration of molybdenum is adequate, air-kerma rates were determined and spectra were obtained. (author)

  16. Mammography parameters: compression, dose, and discomfort

    International Nuclear Information System (INIS)

    Blanco, S.; Di Risio, C.; Andisco, D.; Rojas, R.R.; Rojas, R.M.

    2017-01-01

    Objective: To confirm the importance of compression in mammography and relate it to the discomfort expressed by the patients. Materials and methods: Two samples of 402 and 268 mammographies were obtained from two diagnostic centres that use the same mammographic equipment, but different compression techniques. The patient age range was from 21 to 50 years old. (authors) [es

  17. Performance of clinical mammography: a nationwide study from Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Vejborg, Ilse; Severinsen, Niels

    2006-01-01

    that clinical mammography worked best in patient populations of purely symptomatic women. Our data indicate that to increase the accuracy of clinical mammography at the community level, the presence of an experienced radiologist should be prioritized ahead of raising the clinic size.......Clinical mammography is the key tool for breast cancer diagnosis, but little is known about the impact of the organisational set-up on the performance. We evaluated whether organisational factors influence the performance of clinical mammography. Clinical mammography data from all clinics...... in Denmark in the year 2000 were collected and linked to cancer outcome. Use of the National Institute of Radiation Hygiene register for identification of radiology clinics ensured comprehensive nationwide registration. We used the final mammographic assessment at the end of the imaging work-up to determine...

  18. Mammography screening services: market segments and messages.

    Science.gov (United States)

    Scammon, D L; Smith, J A; Beard, T

    1991-01-01

    Mammography has become a vital tool for the early detection of breast cancer. Although many organizations and health care facilities are working to educate and motivate women to take advantage of the life saving opportunity that is offered through screening mammography, only twenty percent of women who should be screened actually have the procedure performed. In order to reach women who have not been screened, it is important to learn which factors most strongly motivate those women who do choose to have a mammogram. Depth interviews with 18 women attending a mobile mammography unit were conducted to explore the decision making process of women obtaining mammography screening services and to develop a profile of prevalent emotions, attitudes, and feelings associated with receiving breast cancer screening services. Analysis of the interview transcripts revealed several important themes to which health care professionals can direct marketing and health promotion strategies.

  19. 40 CFR 436.21 - Specialized definitions.

    Science.gov (United States)

    2010-07-01

    ... AND STANDARDS MINERAL MINING AND PROCESSING POINT SOURCE CATEGORY Crushed Stone Subcategory § 436.21... reoccurrence interval of once in 10 years. This information is available in “Weather Bureau Technical Paper No..., actively mined for the production of crushed and broken stone from natural deposits. (e) The term “process...

  20. The effect of proposed crush tests on transport containers

    International Nuclear Information System (INIS)

    1984-09-01

    Crush tests were performed on two AECL F112 packaging specimens, two simulated AECL-CRNL 4H packaging specimens, and on empty steel drums. The 9 m drop test was carried out on two simulated AECL-CRNL 4H packaging specimens for comparison with the effects of the crush test. The tests were filmed using high speed photography and 35mm still photographs

  1. Purbeck Stone - A possible Global Heritage Stone from England

    Science.gov (United States)

    Marker, Brian

    2014-05-01

    By definition, a Global Heritage Stone Resource (GHSR) should have international significance. The Purbeck Group of uppermost Jurassic to lowermost Cretaceous age (Tithonian- Berriasian) outcrops mainly in the Purbeck area of Dorset, England. It was deposited in shallow freshwater to brackish lagoons with occasional marine incursions. Limestones, mainly biosparites, occur at 6 main levels. Differences in bed thickness, jointing and hardness make it suitable for a variety of purposes including dimension stone, monumental and ornamental stone, roofing tiles, paving, flooring and rockery stone. Near the top of the sequence is a dark gastropod biosparite, traditionally called Purbeck Marble, easily carved, which has been extensively used for decorative interior work in churches and cathedrals particularly for fonts, tombs, flooring and facings on columns for example in the medieval cathedrals of Salisbury, Exeter, Durham, York and Wells and Worcester and Westminster Abbey. The stone was extracted at least from Roman times (1st century AD) through the medieval period. Quarrying expanded from about 1700 reaching a peak in the late 18th and 19th centuries. Stone was transported first by sea but later by rail for wider use. Used in many local buildings, it gives an important element of local character. Many of the villages are designated conservation areas with a requirement for repair, maintenance and new building using local stone. Initially the stone was taken from quarries but was later mined. The number of operating companies declined from 15 to 5 over the past 40 years, with 10 active small quarries. Outputs are from few hundred tonnes to a few thousand tonnes per annum or about 9 to 12 years of permitted reserves but the Planning Authority intends to make sufficient provision for production at recent levels for their development plan period. The extraction sites are in an Area of Outstanding Natural Beauty and close to Jurassic Coast World Heritage Site. This might

  2. Kidney Stones (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Kidney Stones KidsHealth / For Parents / Kidney Stones What's in ... other treatments to help remove the stones. How Kidney Stones Form It's the kidneys' job to remove ...

  3. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  4. Bladder stones after bladder augmentation are not what they seem.

    Science.gov (United States)

    Szymanski, Konrad M; Misseri, Rosalia; Whittam, Benjamin; Lingeman, James E; Amstutz, Sable; Ring, Joshua D; Kaefer, Martin; Rink, Richard C; Cain, Mark P

    2016-04-01

    Bladder and renal calculi after bladder augmentation are thought to be primarily infectious, yet few studies have reported stone composition. The primary aim was to assess bladder stone composition after augmentation, and renal stone composition in those with subsequent nephrolithiasis. The exploratory secondary aim was to screen for possible risk factors for developing infectious stones. Patients treated for bladder stones after bladder augmentation at the present institution between 1981 and 2012 were retrospectively reviewed. Data were collected on demographics, surgeries and stone composition. Patients without stone analysis were excluded. Stones containing struvite, carbonate apatite or ammonium acid ureate were classified as infectious. The following variables were analyzed for a possible association with infectious bladder stone composition: gender, history of cloacal exstrophy, ambulatory status, nephrolithiasis, recurrent urea-splitting urinary tract infections, first vs recurrent stones, timing of presentation with a calculus, history of bladder neck procedures, catheterizable channel and vesicoureteral reflux. Fisher's exact test was used for analysis. Of the 107 patients with bladder stones after bladder augmentation, 85 met inclusion criteria. Median age at augmentation was 8.0 years (follow-up 10.8 years). Forty-four patients (51.8%) recurred (14 multiple recurrences, 143 bladder stones). Renal calculi developed in 19 (22.4%) patients with a bladder stone, and 10 (52.6%) recurred (30 renal stones). Overall, 30.8% of bladder stones were non-infectious (Table). Among patients recurring after an infectious bladder stone, 30.4% recurred with a non-infectious one. Among patients recurring after a non-infectious stone, 84.6% recurred with a non-infectious one (P = 0.005). Compared with bladder stones, renal stones were more likely to be non-infectious (60.0%, P = 0.003). Of patients with recurrent renal calculi after an infectious stone, 40.0% recurred with

  5. Reproducibility of Mammography Units, Film Processing and Quality Imaging

    International Nuclear Information System (INIS)

    Gaona, Enrique

    2003-01-01

    The purpose of this study was to carry out an exploratory survey of the problems of quality control in mammography and processors units as a diagnosis of the current situation of mammography facilities. Measurements of reproducibility, optical density, optical difference and gamma index are included. Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is a radiographic examination specially designed for detecting breast pathology. We found that the problems of reproducibility of AEC are smaller than the problems of processors units because almost all processors fall outside of the acceptable variation limits and they can affect the mammography quality image and the dose to breast. Only four mammography units agree with the minimum score established by ACR and FDA for the phantom image

  6. Reduced Renshaw Recurrent Inhibition after Neonatal Sciatic Nerve Crush in Rats

    Directory of Open Access Journals (Sweden)

    Liang Shu

    2014-01-01

    Full Text Available Renshaw recurrent inhibition (RI plays an important gated role in spinal motion circuit. Peripheral nerve injury is a common disease in clinic. Our current research was designed to investigate the change of the recurrent inhibitory function in the spinal cord after the peripheral nerve crush injury in neonatal rat. Sciatic nerve crush was performed on 5-day-old rat puppies and the recurrent inhibition between lateral gastrocnemius-soleus (LG-S and medial gastrocnemius (MG motor pools was assessed by conditioning monosynaptic reflexes (MSR elicited from the sectioned dorsal roots and recorded either from the LG-S and MG nerves by antidromic stimulation of the synergist muscle nerve. Our results demonstrated that the MSR recorded from both LG-S or MG nerves had larger amplitude and longer latency after neonatal sciatic nerve crush. The RI in both LG-S and MG motoneuron pools was significantly reduced to virtual loss (15–20% of the normal RI size even after a long recovery period upto 30 weeks after nerve crush. Further, the degree of the RI reduction after tibial nerve crush was much less than that after sciatic nerve crush indicatig that the neuron-muscle disconnection time is vital to the recovery of the spinal neuronal circuit function during reinnervation. In addition, sciatic nerve crush injury did not cause any spinal motor neuron loss but severally damaged peripheral muscle structure and function. In conclusion, our results suggest that peripheral nerve injury during neonatal early development period would cause a more sever spinal cord inhibitory circuit damage, particularly to the Renshaw recurrent inhibition pathway, which might be the target of neuroregeneration therapy.

  7. Calcium oxalate stone and gout.

    Science.gov (United States)

    Marickar, Y M Fazil

    2009-12-01

    Gout is well known to be produced by increased uric acid level in blood. The objective of this paper is to assess the relationship between gout and calcium oxalate stone formation in the humans. 48 patients with combination of gout and calcium oxalate stone problem were included. The biochemical values of this group were compared with 38 randomly selected uric acid stone patients with gout, 43 stone patients with gout alone, 100 calcium oxalate stone patients without gout and 30 controls, making a total of 259 patients. Various biochemical parameters, namely serum calcium, phosphorus and uric acid and 24-h urine calcium, phosphorus, uric acid, oxalate, citrate and magnesium were analysed. ANOVA and Duncan's multiple-range tests were performed to assess statistical significance of the variations. The promoters of stone formation, namely serum calcium (P stone patients and gouty calcium oxalate stone patients compared to the non-gouty patients and controls. Urine oxalate (P stones patients. The inhibitor urine citrate (P stone gouty patients, followed by the gouty uric acid stone formers and gouty calcium oxalate stone patients. The high values of promoters, namely uric acid and calcium in the gouty stone patients indicate the tendency for urinary stone formation in the gouty stone patients. There is probably a correlation between gout and calcium oxalate urinary stone. We presume this mechanism is achieved through the uric acid metabolism. The findings point to the summation effect of metabolic changes in development of stone disease.

  8. Bone Genes in the Kidney of Stone Formers

    Science.gov (United States)

    Evan, Andrew P.; Bledsoe, Sharon B.

    2008-09-01

    Intraoperative papillary biopsies from kidneys of idiopathic-calcium oxalate stone formers (ICSF) have revealed a distinct pattern of mineral deposition in the interstitium of the renal papilla. The earliest sites of these deposits, termed Randall's plaque, are found in the basement membrane of thin loops of Henle and appear to spread into the surrounding interstitium down to the papillary epithelium. Recent studies show kidney stones of ICSF patients grow attached to the renal papilla and at sites of Randall's plaque. Together these observations suggest that plaque formation may be the critical step in stone formation. In order to control plaque formation and thereby reduce future kidney stone development, the mechanism of plaque deposition must be understood. Because the renal papilla has unique anatomical features similar to bone and the fact that the interstitial deposits of ICSF patients are formed of biological apatite, this paper tests the hypothesis that sites of interstitial plaque form as a result of cell-mediated osteoblast-like activity.

  9. Mammography: an update of the EUSOBI recommendations on information for women.

    Science.gov (United States)

    Sardanelli, Francesco; Fallenberg, Eva M; Clauser, Paola; Trimboli, Rubina M; Camps-Herrero, Julia; Helbich, Thomas H; Forrai, Gabor

    2017-02-01

    This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a small number of women who undergo the test. Information is given on the recall during a screening programme and on the request for further work-up after a diagnostic mammography. The logic of the mammography report and of classification systems such as R1-R5 and BI-RADS is illustrated, and brief but clear information is given about the diagnostic performance of the test, with particular reference to interval cancers, i.e., those cancers that are missed at screening mammography. Moreover, the breast cancer risk due to radiation exposure from mammography is compared to the reduction in mortality obtained with the test, and the concept of overdiagnosis is presented with a reliable estimation of its extent. Information about new mammographic technologies (tomosynthesis and contrast-enhanced spectral mammography) is also given. Finally, frequently asked questions are answered. • Direct digital mammography should be preferred to film-screen or phosphor plates. • Screening (in asymptomatic women) should be distinguished from diagnosis (in symptomatic women). • A breast symptom has to be considered even after a negative mammogram. • Digital breast tomosynthesis increases cancer detection and decreases the recall rate. • Contrast-enhanced spectral mammography can help in cancer detection and lesion characterisation.

  10. Preparation-induced errors in EPR dosimetry of enamel: pre- and post-crushing sensitivity

    International Nuclear Information System (INIS)

    Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1996-01-01

    Errors in dose estimation as a function of grain size for tooth enamel has been previously shown for beta irradiation after crushing. We tested the effect of gamma radiation applied to specimens before and after crushing. We extend the previous work in that we found that post-crushing irradiation altered the slope of the dose-response curve of the hydroxyapatite signal and produced a grain-size dependent offset. No changes in the slope of the dose-response curve were seen in enamel caps irradiated before crushing

  11. Assessment of crushed-recycled glass as filter media for drinking water treatment

    International Nuclear Information System (INIS)

    Rutledge, S.O.; Fahie, C.; Gagnon, G.A.

    2002-01-01

    The objective of this project was to evaluate the performance of a pressure filter utilizing crushed glass as the filter media. The performance of the crushed glass filter was compared to that of a sand filter. The research was conducted in Orangedale, Nova Scotia, which is a small community of with a population of approximately 500. Orangedale is located on the south shore of Bras d'Or Lakes and feeds into Miller Pond, which serves as the source the of drinking water. The Orangedale treatment plant produces an average daily flow of 35 m3/d (6.4-gpm). The treatment plant consists of coagulation (sodium aluminate and polyaluminum chloride), flocculation, dissolved air flotation (DAF), disinfection with sodium hypochlorite and dual-media filtration with anthracite and sand. In general, the particle removal capabilities of the crushed glass filter were slightly poorer than that of a sand filter, as quantified in a field application in the community of Orangedale, Nova Scotia. It was found that the crushed glass used in this project had a higher angularity and slightly higher uniformity coefficient. During initial start-up the performance of the crushed glass filter was more variable and appeared to improve as the glass began to wear. After six-months of use the crushed glass filter was able to produce a very consistent filter effluent that was only slightly greater than the silica sand filter. After six-months of use, the sand filter achieved a 1.6 log-removal of particles with diameters greater than 2 μm; whereas the crushed glass filter achieved a 1.4 log removal for the similar particle size range. The observed removal performance was particularly encouraging given that the sand used had properties that were consistent with the standards set by the American Water Works Association. The crushed glass filter media was initially sieved and washed, but had no other pre-treatment preparation. Thus the application of crushed glass shows considerable promise as filter

  12. Risks, radiation dose and image quality of mammography

    International Nuclear Information System (INIS)

    Menges, V.

    1979-01-01

    For some time to come, early detection of breast cancer will remain the only way to improve the therapeutical success. Mammography is an absolutely indispensible way to take advantage of this opportunity. Today, mammography is undoubtedly the most reliable method of examination for an early detection of breast cancer. Only mammography can detect carcinomas smaller than the critical tumour size of 1cm. If carried out properly and with present dose levels, it involves hardly any radiation risk. (orig.) [de

  13. Computer-aided diagnosis in routine mammography

    International Nuclear Information System (INIS)

    Sittek, H.; Perlet, C.; Helmberger, R.; Linsmeier, E.; Kessler, M.; Reiser, M.

    1998-01-01

    Purpose: Computer-aided diagnosis in mammography is a topic many study groups have been concerned with since the first presentation of a system for computer-aided interpretation in 1967. Currently, there is only one system avilable for clinical use in mammography, the CAD-System Image Checker (R2 Technology). The purpose of our prospective study was to evaluate whether the integration of the CAD-system into the routine of a radiological breast diagnosis unit is feasible. Results: After the installation of the CAD-system, 300 patients with 1110 mammograms were included for evaluation in the present study. In 54 of these cases histological examination was indicated due to suspect criteria on conventional mammography. In 39 of 54 cases (72,2%) malignancy could be proven histologically. The CAD-system marked 82,1% of the histologically verified carcinomas correctly 94,3% of all 1797 marks made by the CAD-system indicated normal or benign structures. Routinely performed CAD analysis prolonged patients waiting time by about 15 min because the marks of the CAD system had to be interpreted in addition to the routine diagnostic investigations. Conclusion: Our experience with the use of the CAD-system in daily routine showed that CAD analysis can easily be integrated into a preexisting mammography unit. However, the diagnostic benefit is not yet clearly established. Since the rate of false negative marks by the CAD-system Image Checker is still high, the results of CAD analysis must be checked and corrected by an observer well experienced in mammography reading. (orig.) [de

  14. Mammography

    International Nuclear Information System (INIS)

    1975-01-01

    This patent reveals a method and instrument for the detection and registration of breast cancer with the aid of X-radiation, i.e. mammography. The breast is irradiated with soft X-rays whereby the radiation beam is scanned with a moving 'stripform' screen and whereby the picture from the 'stripform' screen is recorded by a television camera that moves simultaneously with the strip. The image is then projected on a monitor

  15. Investigation on Compressive Strength of Special Concrete made with Crushed Waste Glass

    Directory of Open Access Journals (Sweden)

    Mohd Sani Mohd Syahrul Hisyam

    2015-01-01

    Full Text Available Special concrete is the type of concrete that produced by using waste material or using unusual techniques/method of preparation. Special concrete made with waste material is becoming popular in a construction site. This is because the special concrete is selected due to quality, integrity, economic factor and environmental factor. The waste glass is selected as an additional material to provide a good in compressive strength value. The compressive strength is the importance of mechanical properties of concrete and typically the concrete is sustained and stiffed in compression load. The significant issue to utilize the waste glass from the automotive windscreen is to improve the strength of concrete. The waste glass is crushed to become 5 mm size and recognised as crushed waste glass that be used in concrete as additional material. The main objective of the study is to determine the appropriate percentage of crushed waste glass in concrete grade, 30 in order to enhance the compressive strength. There are four mixes of concrete that contained of crushed waste glass with percentage of 2 %, 4 %, 6 % and 8 % and one control mix with 0 % of crushed waste glass. As the result, crushed waste glass with an additional 4 % in concrete is reported having a higher value of compressive strength in early and mature stage. In addition, if the percentage of crushed glass wastes in concrete increases and it leads to a reduction in the workability of concrete.

  16. Research for the development of the crushed sand (II)

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Whan; Kang, Sun Duck; Min, Jeong Sik; Synn, Joong Ho; Park, Chan [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The sand obtained from river is not sufficient in amount for the demand of construction industry. The production of sand from sea and mountain is rapidly increasing for the substitution of the river sand. The industry of the crushed sand has recently been bricked for the above. Crushing, classification and dewatering are the main processes in the crushed sand production. This report concentrates the improvement of classification technology and the quality of ready mixed concrete. Air separator with testing size for the classification in the process of dry system was developed by the Yeung Nam university. This plant has the excellent efficiency for the collection of fine powder, but needs the improvement for separating function. The collection efficiency of the testing size air separator is reached to 99% in the condition of high revolution and low feeding speed. The classification efficiency is checked about 50% maximum in the condition of 200 rpm and dry sample. Energy saving test was carried out in the production process of the dry system with the rock samples of 14-17% of water content. The classification efficiency for dewatering sample passed the heating process was analysed 91.5%. But that for high water content sample skipped the heating process was analysed more or less 77%. Even though the heating process causes the classification efficiency being high, the energy consumption can also cause the price of the crushed sand high. Water content of sample as the effective element for the optimization of classification efficiency and energy saving should be studied next year. The quality of crushed sand in the mixing design. The test was carried out with the various content in mixing, the strength of ready mixed concrete has the maximum for the mould with 50-60% content of crushed sand. This strength is higher by 5-30% than 30% content and by 20-32% than 0% content, which means that the industry has the possibility of progress. (author). 10 refs., 31 tabs., 49

  17. Mammography discomfort: a holistic perspective derived from women's experiences

    International Nuclear Information System (INIS)

    Poulos, Ann; Llewellyn, Gwynnyth

    2005-01-01

    Purpose: Mammography discomfort has the potential to deter women from attending for regular breast screening. Previous studies have focussed on the pain/discomfort of the mammography procedure itself. The purpose of this study was to consider discomfort from a holistic perspective of the mammography experience derived from the women themselves. Methods: Qualitative research methods were employed. Using theoretical sampling, 12 women who had recently experienced mammography were interviewed. The interview questions aimed to explore the experience of women attending for a mammogram from arrival to departure and beyond in order to identify aspects which potentially increase discomfort. Data analysis involved coding and categorisation and identification of key concepts and their relationships. Results: A conceptual framework was developed that demonstrates the contributors to mammography discomfort and the relationships between these as identified by the women. Conclusions: The conceptual framework has important implications for clinical practice and future research

  18. Acute management of stones

    DEFF Research Database (Denmark)

    Jung, Helene; Osther, Palle J S

    2015-01-01

    INTRODUCTION: Stone management is often conservative due to a high spontaneous stone passage rate or non-symptomatic calyceal stones that do not necessarily require active treatment. However, stone disease may cause symptoms and complications requiring urgent intervention. MATERIAL AND METHODS: I...... with careful consideration of stone size and location, symptoms, patient comorbidity and radiation dose. CONCLUSION: In case of infective hydronephrosis, compromised renal function or persistent pain despite adequate analgesic treatment acute intervention is indicated....

  19. The personal costs and convenience of screening mammography.

    Science.gov (United States)

    Suter, Lisa Gale; Nakano, Connie Y; Elmore, Joann G

    2002-09-01

    Few studies have examined the impact of women's personal costs on obtaining a screening mammogram in the United States. All women obtaining screening mammograms at nine Connecticut mammography facilities during a 2-week study period were asked to complete a questionnaire. Facilities included urban and rural fixed sites and mobile sites. The survey included questions about insurance coverage, mammogram payment, and personal costs in terms of transportation, family care, parking, and lost work time from the women's perspective. The response rate was 62% (731 of 1189). Thirty-two percent of respondents incurred some type of personal cost, including lost work time, family care, and parking. Women incurring personal costs were more likely than those without personal costs to attend an urban facility (46% vs. 23%, p convenience and 17% listed cost as a reason for choosing a mammography facility; 23% reported that cost might prevent them from obtaining a future mammogram. One third of women obtaining mammograms may be incurring personal costs. These personal costs should be considered in future cost-effectiveness analyses.

  20. Treatment of gallbladder stone with common bile duct stones in the laparoscopic era

    OpenAIRE

    Zhang, Wei-jie; Xu, Gui-fang; Huang, Qin; Luo, Kun-lun; Dong, Zhi-tao; Li, Jie-ming; Wu, Guo-zhong; Guan, Wen-xian

    2015-01-01

    Background: Laparoscopic common bile duct exploration (LCBDE) for stone can be carried out by either laparoscopic transcystic stone extraction (LTSE) or laparoscopic choledochotomy (LC). It remains unknown as to which approach is optimal for management of gallbladder stone with common bile duct stones (CBDS) in Chinese patients. Methods: From May 2000 to February 2009, we prospective treated 346 consecutive patients with gallbladder stones and CBDS with laparoscopic cholecystectomy and LCBDE....

  1. Barriers to Mammography among Inadequately Screened Women

    Science.gov (United States)

    Stoll, Carolyn R. T.; Roberts, Summer; Cheng, Meng-Ru; Crayton, Eloise V.; Jackson, Sherrill; Politi, Mary C.

    2015-01-01

    Mammography use has increased over the past 20 years, yet more than 30% of women remain inadequately screened. Structural barriers can deter individuals from screening, however, cognitive, emotional, and communication barriers may also prevent mammography use. This study sought to identify the impact of number and type of barriers on mammography…

  2. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  3. Traceability and quality control in mammography: measurements and models

    International Nuclear Information System (INIS)

    Peixoto, Jose Guilherme Pereira

    2002-10-01

    The success of a treatment or diagnosis using radiation, depends on the optimization of the dose determination to be administered for the patient and on the beam radiation quality. It is recognized by the international guidelines that it is necessary to improve calibration services for mammography beams in order to improve the quality of clinical diagnosis. Major efforts have been made by several laboratories in order to establish an appropriate and traceable calibration infrastructure and to provide the basis for a quality control program in mammography. The contribution of the radiation metrology network to the mammography services is reviewed in this work. Steps required for the implementation of a mammography calibration system using a constant potential x-ray and a clinical mammography x-ray machine are presented. The various qualities of mammography radiation discussed in this work are in accordance with the IEC 61674 and the AAPM recommendations. This work also presents the methodology and the procedures to maintain and to disseminate the traceability at the x-ray mammography range, describing the interlaboratory comparison performed at LNMRI/IRD/CNEN and at the IPEN/CNEN using the secondary standard ionization chambers traceable with the international standard. It assesses the inter-laboratory comparison consistency and decides whether a questionable value should or not be accepted, using the residual method. This thesis discusses the uncertainties involved in all steps of the calibration chain in accord once with the ISO recommendations. (author)

  4. Wastes disposal on board a ship. Crushing and volume reducing apparatus for combustible and non-combustible refuses; Senjo no haikibutsu shori. Kanen funen gomi no hasai gen`yo shori sochi

    Energy Technology Data Exchange (ETDEWEB)

    Kishida, Y. [Hitachi Zosen Corp., Osaka (Japan)

    1996-07-25

    This paper introduces a refuse crushing apparatus to reduce for storage the volume of refuses produced on board a ship by crushing. Refuses to be crushed are solid wastes including solid combustible refuses such as paper, wood pieces, and cloths, non-combustible refuses such as empty cans, metals and glass, and refuses unsuitable for combustion, such as plastics and stylofoam. Crushing methods include impact system, compression system and shearing system. The shearing system shears and crushes refuses by using blades rotating at a low speed. The system has a wide range of crush ability and excellent versatility, generates low levels of dust, noise and vibration, and is suitable as a marine use refuse disposing apparatus. However, empty cans and PET bottles are more difficult of getting into cutting blades requiring a large amount of time for crushing. Therefore, it is more suitable to reduce volume of refuses by using a compressor or the like apparatuses, and then crush them by using a double-axial shearing crusher. Stylofoam causes its crushed pieces to be electrically charged and deposited onto the apparatus, hence it is more suitable to reduce the volume of refuses and make them brittle by heating, and then crush them by using the double-axial crusher. 2 figs.

  5. Digital mammography with high-resolution storage plates (CR) versus full-field digital mammography (CCD) (DR) for microcalcifications and focal lesions - a retrospective clinical histologic analysis (n = 102)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Lell, M.; Wenkel, E.; Boehner, C.; Dassel, M.S.; Bautz, W.

    2005-01-01

    Purpose: to determine the diagnostic accuracy of microcalcifications and focal lesions in a retrospective clinical-histological study using high-resolution digital phosphor storage plates (hard copy) and full-field digital mammography (hard copy). Materials and methods: from May 2003 to September 2003, 102 patients underwent digital storage plate mammography (CR), using a mammography unit (Mammomat 3000 N, Siemens) in combination with a high resolution (9 lp/mm) digital storage phosphor plate system (pixel size 50 μm) (Fuji/Siemens). After diagnosis and preoperative wire localization, full-field digital mammography (CCD) (DR) was performed with the same exposure parameters. The full-field digital mammography used a CCD-detector (SenoScan) (fisher imaging) with a resolution of 10 Ip/mm and a pixel size of 50 μm. Five investigators determined the diagnosis (BI-RADS trademark I-V) retrospectively after the operation from randomly distributed mediolateral views (hard copy reading). These results were correlated with the final histology. Results: the diagnostic accuracy of digital storage plate mammography (CR) and full-field digital mammography (CCD) (DR) was 73% and 71% for all findings (n = 102), 73% and 71% for microcalcifications (n = 51), and 72% and 70% for focal lesions (n = 51). The overall results showed no difference. Conclusion: our findings indicate the equivalence of high-resolution digital phosphor storage plate mammography (CR) and full-field digital mammography (CCD) (DR). (orig.)

  6. Metabolic Characteristics and Risks Associated with Stone Recurrence in Korean Young Adult Stone Patients.

    Science.gov (United States)

    Kang, Ho Won; Seo, Sung Pil; Kim, Won Tae; Kim, Yong-June; Yun, Seok-Joong; Kim, Wun-Jae; Lee, Sang-Cheol

    2017-08-01

    The aim of this study was to assess the metabolic characteristics and risks of stone recurrence in young adult stone patients in Korea. The medical records of 1532 patients presenting with renal or ureteric stones at our stone clinic between 1994 and 2015 were retrospectively reviewed. Patients were grouped according to age (young adult, 18-29 years; intermediate onset, 30-59 years; old age, ≥60 years) at first presentation, and measurements of clinicometabolic characteristics and risks of stone recurrence were compared. Overall, excretion of urinary stone-forming substances was highest in the intermediate onset group, followed by the young adult and old age groups. Importantly, excretion of urinary citrate was lowest in the young adult group. Kaplan-Meier analyses identified a significant difference between the three age groups in terms of stone recurrence (log rank test, p adult stone patients. Younger age (18-29 years) at first stone presentation was a significant risk factor for stone recurrence, and urinary citrate excretion was an independent risk factor affecting recurrence in this group. Metabolic evaluation and potassium citrate therapy should be considered for young adult stone patients to prevent recurrence.

  7. De-stoning technology for improving olive oil nutritional and sensory features: The right idea at the wrong time.

    Science.gov (United States)

    Restuccia, Donatella; Clodoveo, Maria Lisa; Corbo, Filomena; Loizzo, Monica Rosa

    2018-04-01

    De-stoning technology has been introduced in the olive oil sector more than twenty years ago. It has not gained momentum because, sometimes, innovative ideas are not accepted since they are suggested at the wrong time or under the wrong circumstances. Virgin olive oil (VOO) is one of the most popular functional foods, mainly due to its antioxidant properties. These features, as well as other nutritional characteristics are generally enhanced by the de-stoning process. However, despite the improvement of the nutritional value, in the past the de-stoned oil didn't achieve marketing success mainly in relation to technological limitations (i.e. low oil yield). Only in recent years healthy properties became an element able to influence consumers' behavior, overcoming the limit of low oil yields and attracting the attention of olive oil producers. An analysis of the advantages, in terms of product quality and process sustainability, is given in this review. Here, for the first time, the fragmented results reported in literature are critically analyzed underlining the contradictions reported by different authors showing the main reasons for the unlucky fate of this technology in the industrial sector. In the final section the challenges, that future research must focus on, are presented, including emerging technologies in VOO processing. Literature data, for the first time discussed here exhaustively, show that de-stoning technology is a mechanical strategy useful to increase the nutritional and the sensory quality of the product. Moreover, it reduces the depletion of natural resources obtaining a selective crushing of the drupe by removing the stones from the olive paste so increasing the sustainability and efficiency of VOO extraction plants. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Evaluation of quality in Service of Mammography of the State of Pernambuco

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Hwang, Suy F.; Peixoto, Joao Emilio

    2001-01-01

    The cancer of breast is what more contributes to mortality among women in the world. In 2000, it is considered that happened about 28.300 new cases and 8.200 death in Brazil. Thus, programs of precocious detection have been transmitted and driven the professionals of health and the population, where the used method and indicated for the diagnosis it is the mammography. However, to be capable to detect small lesions, still without clinical expression, the Service of Mammography should have mechanisms that guarantee the quality and effectiveness of the exam, assuring the great levels of sensibility and of specific. That work has as objective to evaluate the quality of the Services of Mammography of the State of Pernambuco, seeking to adapt them to the effective norms, guaranteeing like this the success of programs of precocious detection. Results show that 55% of the Services present problems in the envisage of the bunch of ray-X, 57% of the apparels do not present system of automatic control of the exhibition (CAE) regulated or it does not exist, by force of compression of 37% of the apparels they were out of the interval of tolerance (11 to 18 kg) and 36% of the processor were just in conformity with the operation patterns for mammography. Of the one of the 31 Services evaluated 3 they were just totally approved, while 10 did not present minimum quality for the diagnosis. (author)

  9. Extracorporeal shock wave lithotripsy for renal stone with infundibular stenosis

    International Nuclear Information System (INIS)

    Lee, Won Hong; Son, Soon Yong; Kang, Seong Ho; Lee, Yong Moon; Yoon, Seok Hwan

    2006-01-01

    We analyzed retrospectively our experience to evaluate an effect of extracorporeal shock wave lithotripsy (ESWL) for renal stone with infundibular stenosis. From January 2002 to August 2005, 35 patients with renal stone with infundibular stenosis were treated with ESWL. The diagnosis of infundibular stenosis was made by intravenous pyelography or retrograde pyelography. The final follow-up check was performed by simple abdominal film or computed tomography and interview after 6 months to 24 months (mean 10 months). 7 (20.0%) of 35 patients was freed completely, but Stone free rate including less than 2 mm size was 80% (28/35). 30 (85.7%) patients became asymptomatic, 4 (11.4%) patients were continued, and 1 (2.9%) patient was required the percutaneous nephrostolithotomy. Although ESWL has a low complete stone free rate, We suggest that renal stone with infundibular stenosis should be treated with ESWL, because that is likely to produce a high symptom free and low complications

  10. Extracorporeal shock wave lithotripsy for renal stone with infundibular stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Hong; Son, Soon Yong; Kang, Seong Ho; Lee, Yong Moon [Asan Medical Center, Seoul (Korea, Republic of); Yoon, Seok Hwan [Dongnam Health College, Suwon (Korea, Republic of)

    2006-06-15

    We analyzed retrospectively our experience to evaluate an effect of extracorporeal shock wave lithotripsy (ESWL) for renal stone with infundibular stenosis. From January 2002 to August 2005, 35 patients with renal stone with infundibular stenosis were treated with ESWL. The diagnosis of infundibular stenosis was made by intravenous pyelography or retrograde pyelography. The final follow-up check was performed by simple abdominal film or computed tomography and interview after 6 months to 24 months (mean 10 months). 7 (20.0%) of 35 patients was freed completely, but Stone free rate including less than 2 mm size was 80% (28/35). 30 (85.7%) patients became asymptomatic, 4 (11.4%) patients were continued, and 1 (2.9%) patient was required the percutaneous nephrostolithotomy. Although ESWL has a low complete stone free rate, We suggest that renal stone with infundibular stenosis should be treated with ESWL, because that is likely to produce a high symptom free and low complications.

  11. COMPARATIVE STUDY OF CULTURE AND SENSITIVITY PATTERNS OF PRE OPERATIVE MID STREAM URINE WITH RENAL PELVIC URINE AND STONE TO PREDICT UROSEPSIS FOLLOWING PERCUTANEOUS NEPHROLITHOTOMY: A PROSPECTIVE CLINICAL STUDY

    Directory of Open Access Journals (Sweden)

    Bhargava Vardhana Reddy

    2015-11-01

    Full Text Available INTRODUCTION : Percutaneous nephrolithotomy (PCNL is the most frequently performed surgery for stone disease at our institution. Nearly 100 PCNL procedures are being performed in a year at our institution. Septicemia following PCNL can be catastrophic despite sterile preoperative urine and prophylactic antibiotics. Infected stones, obstructed kidneys , and comorbidit y have been held responsible. In this study we analyzed various culture specimens, namely Mid - stream urine (MSU, renal pelvic urine and crushed stones. MATERIALS AND METHODS : We performed a prospective clinical study in all our patients undergoing PCNL b etween January 2013 and December 2014. MSU was sent for culture and sensitivity testing (C&S one day prior to surgery. Percutaneous access into the ipsilateral pelvicaliceal system is achieved under image intensification using a fine, 14 gauge Kellet need le. Urine from the pelvicaliceal system is first aspirated and sent as pelvic urine C&S. Stone fragments are collected to be proces0sed for C&S. The data collected were divided into 3 main groups, that is MSU C&S, pelvic urine C&S and stone C&S. RESULTS : A total of 83 patients were included in the study, of this MSU C&S was positive in 9/83 (10.8% patients, Pelvic C&S in 10 /73 (13.7% patients and Stone C&S in 25/83 (30.1% patients. Out of 25 cases of stone culture positive patients 17 patients develope d Systemic Inflammatory Response Syndrome (SIRS but only 2 patients developed SIRS in MSU C & S positive patients. CONCLUSIONS: The results of our study suggest that positive stone C&S is the better predictor of potential urosepsis than MSU. Stone cultur e is available only after surgery but appears to be the best guide for antibiotic therapy in case of sepsis. So the routine collection of stone for C&S will be beneficial

  12. Mammography screening among Arab American women in metropolitan Detroit.

    Science.gov (United States)

    Schwartz, Kendra; Fakhouri, Monty; Bartoces, Monina; Monsur, Joseph; Younis, Amani

    2008-12-01

    Mammography screening behavior has not been well studied among Middle Eastern immigrant women. We conducted a telephone survey of 365 Arab American women residing in metropolitan Detroit, home to one of the largest populations of Middle Eastern immigrants in the US, to determine prevalence of factors associated with mammography, and attitudes and beliefs regarding mammography screening. Of 365 participants, only five were born in the US. Mean age was 53.2 years (SD 10.8). Two hundred twelve (58.1%) reported having mammogram every 1-2 years; 70% ever had mammogram. Age 50-64 years, having health insurance, married status, being in the US over 10 years, and being Lebanese were associated with mammography every 1-2 years. After adjusting for demographic factors, perceived seriousness of disease, general health motivation, and having fewer barriers were associated with more frequent screening. Appropriate mammography screening is decreased in this group. Targeted outreach regarding screening is appropriate for this population; however, lack of insurance may prevent adequate follow-up.

  13. Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

    Science.gov (United States)

    Cheung, Yun-Chung; Lin, Yu-Ching; Wan, Yung-Liang; Yeow, Kee-Min; Huang, Pei-Chin; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chang, Chee-Jen

    2014-10-01

    To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). CESM cases of dense breasts with histological proof were evaluated in the present study. Four radiologists with varying experience in mammography interpretation blindly read Mx first, followed by CESM. The diagnostic profiles, consistency and learning curve were analysed statistically. One hundred lesions (28 benign and 72 breast malignancies) in 89 females were analysed. Use of CESM improved the cancer diagnosis by 21.2 % in sensitivity (71.5 % to 92.7 %), by 16.1 % in specificity (51.8 % to 67.9 %) and by 19.8 % in accuracy (65.9 % to 85.8 %) compared with Mx. The interobserver diagnostic consistency was markedly higher using CESM than using Mx alone (0.6235 vs. 0.3869 using the kappa ratio). The probability of a correct prediction was elevated from 80 % to 90 % after 75 consecutive case readings. CESM provided additional information with consistent improvement of the cancer diagnosis in dense breasts compared to Mx alone. The prediction of the diagnosis could be improved by the interpretation of a significant number of cases in the presence of 6 % benign contrast enhancement in this study. • DE-CESM improves the cancer diagnosis in dense breasts compared with mammography. • DE-CESM shows greater consistency than mammography alone by interobserver blind reading. • Diagnostic improvement of DE-CESM is independent of the mammographic reading experience.

  14. Assessment of Clinical Practices for Crushing Medication in Geriatric Units.

    Science.gov (United States)

    Fodil, M; Nghiem, D; Colas, M; Bourry, S; Poisson-Salomon, A-S; Rezigue, H; Trivalle, C

    2017-01-01

    To assess the modification of the form of medication and evaluate staff observance of good clinical practices. One-day assessment of clinical practices. 17 geriatrics units in the 3 Teaching Hospitals of Paris-Sud (APHP), France. Elderly in-patients with difficulties swallowing capsules and tablets. Assessment of target-patient prescriptions and direct observation of nurses' medical rounds. 155/526 in-patients (29.5%) were unable to swallow tablets or capsules: 98 (40.3%) in long-term care, 46 patients (23.8%) in the rehabilitation unit and 11 (12.2%) in the acute care unit (p = .005). In thirty-nine (27.3%) of the 143 prescriptions studied all tablets were safe to crush and all capsules were safe to open. In 104 cases, at least one medication could not be safely modified, including 26 cases (18.2%) in which none of the prescribed drugs were safe to crush or open. In 48.2% of the 110 medications that were crushed, crushing was forbidden, and presented a potential threat in 12.7% of cases or a reduced efficacy in 8.2% of cases. Crushing methods were rarely appropriate: no specific protective equipment was used (81.8%), crushing equipment was shared between patients without cleaning (95.1%), medications were spilled or lost (69.9%). The method of administration was appropriate (water, jellified water) in 25% of the cases, questionable (soup, coffee, compote, juice, cream) in 55% of the cases and unacceptable (laxative) in 21% of the cases. Management of drug prescriptions in patients with swallowing difficulties is not optimal, and may even have iatrogenic effects. In this study, 12.7% of the modifications of the drug form could have been harmful. Doctors, pharmacists and nurses need to reevaluate their practices.

  15. Mammography and ultrasound in the evaluation of male breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Carrasco, Rafaela; Alvarez Benito, Marina; Raya Povedano, Jose Luis [Hospital Universitario ' Reina Sofia' , Radiology Department, Cordoba (Spain); Munoz Gomariz, Elisa [Hospital Universitario ' Reina Sofia' , Support Unit for Research, Cordoba (Spain); Martinez Paredes, Maria [University of Cordoba, Radiology and Physical Medicine Area, Cordoba (Spain)

    2010-12-15

    To assess clinical variables that may be useful in differentiating gynaecomastia from carcinoma and to analyse the contribution of mammography and ultrasound to the evaluation of male breast disease. All men who underwent mammography and/or ultrasound between 1993 and 2006 in our hospital were retrospectively evaluated. Clinical characteristics in patients with gynaecomastia and those with carcinoma were compared. Radiological findings were classified according to the BI-RADS (Breast Imaging Reporting and Data System) criteria. The diagnostic performance of physical examination, mammography and ultrasound was determined and compared. A total of 628 patients with 518 mammograms and 423 ultrasounds were reviewed. The final diagnoses were: 19 carcinomas, 526 gynaecomastias, 84 other benign conditions and 25 normal. There were statistically significant differences in age, bilateral involvement, clinical presentation and physical examination between patients with carcinoma and those with gynaecomastia. The diagnostic performance of physical examination was lower than that of mammography and ultrasound (p < 0.05 for specificity). Mammography was the most sensitive (94.7%) and ultrasound the most specific (95.3%) for detection of malignancy (p > 0.05). We propose an algorithm for the use of mammography and ultrasound in men. Mammography and ultrasound, with a negative predictive value close to 100%, make it possible to avoid very many unnecessary surgical procedures in men. (orig.)

  16. Stone composition and metabolic status.

    Science.gov (United States)

    Bibilash, B S; Vijay, Adarsh; Fazil Marickar, Y M

    2010-06-01

    This paper aims to study the correlation between biochemical risk factors of the stone former and the type of oxalate stone formed, namely calcium oxalate monohydrate (COM) and calcium oxalate dehydrate (COD). A retrospective study of 487 patients who had been attending the urinary stone clinic, Trivandrum during 1998-2007 was conducted. The stones retrieved from them were subjected to chemical analysis and FTIR spectrographic analysis. They were categorized into COM, COD, mixed COM+COD and others. Of 142 pure calcium oxalate stone patients, 87 were predominantly COM stone formers and 55 COD stone formers. Their metabolic status of 24 h urine and serum was assessed. The values of urine calcium, phosphorus, uric acid, magnesium, creatinine, oxalate, citric acid, sodium and potassium, serum values of calcium, phosphorus, uric acid, magnesium and creatinine and calculated values of creatinine clearance, tubular reabsorption of phosphate, calcium magnesium ratio and calcium oxalate ratio were recorded. Comparison was made between the COM stone group and the COD stone group. Patients forming COM stones had significantly higher mean values for urine calcium (P stone forming patients. All other values failed to show significant difference. Patients, with higher urine oxalate, formed COM stones. Those with low magnesium (which is an inhibitor) formed more of COD stones. Urine calcium was high in both groups without showing significant variation from the mean. In patients with high calcium-oxalate and calcium-magnesium ratios, there is higher chance of forming a COD stone than COM. Identification of the crystallization pattern of the calcium stone will help in selecting treatment modalities.

  17. Organization and standards of screening and diagnostic mammography

    International Nuclear Information System (INIS)

    Linderbraten, L.D.; Chikirdin, Eh.G.; Rozhkova, N.I.

    1999-01-01

    Problem of organizing and standards of the reference and diagnostic mammography in our country is discussed. Attention is paid to the terminology, accreditation of mammographic establishments and specialists, specifications of equipment, image quality, mammography results processing, radiation doses [ru

  18. IGCP 637 Heritage Stone Designation: A UNESCO and IUGS project on natural stones

    Science.gov (United States)

    Pereira, Dolores; Cooper, Barry; Schouenborg, Björn; Marker, Brian; Kramar, Sabina

    2017-04-01

    IGCP 637 was approved in 2015 to facilitate establishment of a new international geological standard for building and ornamental stones. Formal international recognition of those natural stone types that have achieved widespread utilization in human culture is now underway and the term "Global Heritage Stone Resource" (GHSR) has been proposed for this designation. Stones that have been used in heritage construction, sculptural masterpieces, as well as in utilitarian (yet culturally important) applications are obvious GHSR candidates. In co-ordination with these aims the project has an associated role to promote the adoption and use of the GHSR designation. Consequently an interim list of potential GHSRs is maintained and a register of GHSR approved stones is being created. IGCP 637 also enhances the capacity of the International Union of Geological Sciences (IUGS) in the realm of dimension stone and geological standards as it is the first IUGS involvement in this subject. As a consequence, the largest known international grouping of dimension stone professionals has been established. Within IGCP 637 a web page has been created at www.globalheritagestone.com, including information on the Working Group and also specific information on the evolution of the project. Several researchers were funded to attend the Heritage Stone working group activities, including researchers from Algeria, Malawi, India, Italy and Russia. We also have produced many publications, both as individual papers and special issues in journals included in the Journal Citation Reports. Monographs are being prepared at present. Hopefully, IGCP 637 will help to widen the circle of researchers interested in natural stones as part of our geoheritage. Heritage Stone references: articles and special issues - Pereira, D. and Marker, B. (2016) The value of original natural stone in the context of architectural heritage. Geosciences, 6, 13. - Heritage Stone 1. Ed. Pereira and Pratt. (2016). Geoscience

  19. Breast cancer imaging: Mammography among women of up to 45 years

    International Nuclear Information System (INIS)

    Schnejder-Wilk, A.

    2010-01-01

    Background: Among women under the age of 40, screening mammography examinations are not performed routinely. An ultrasonography scan is considered to be a basic breast imaging examination among younger women. The purpose of this study was to analyze mammography images, as well as to evaluate the usefulness and role of mammography in breast cancer diagnostic processes in women of up to 45 years, based on own experience. Material/Methods: A retrospective analysis of mammography images, including 144 cases of breast cancer diagnosed in the group of 140 women of 45 years of age. All the patients underwent pre-treatment mammography and surgery procedure. The images were evaluated in accordance to BIRADS criteria. Lesions detectable in mammography were grouped as follows: spiculated mass; nonmicrocalcified oval/round mass; microcalcified mass (regardless of shape); microcalcifications; architectural distortion; breast tissue asymmetry. Results: The most common mammographic symptom was solid tumor (41%), followed by microcalcified tumors (20.8%). Clusters of microcalcifications constituted 17.4% of mammography findings. In 4.9% of mammography scans, examination did not reveal any pathological lesions. Conclusions: Breast cancer mammograms of women aged up to 45 years do not differ from diagnostic pictures of breast cancer in older women. The diagnostic appearance of breast cancer in 1/3 of the patients involved microcalcifications detectable only on mammograms. All the women with suspicion of breast cancer should have their mammography examinations performed, irrespective of ultrasonography scans. (author)

  20. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    International Nuclear Information System (INIS)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez; Castellanos, Gustavo Casian

    2008-01-01

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography

  1. Papillary Ductal Plugging is a Mechanism for Early Stone Retention in Brushite Stone Disease

    DEFF Research Database (Denmark)

    Williams, James C; Borofsky, Michael S; Bledsoe, Sharon B

    2018-01-01

    PURPOSE: Mechanisms of early stone retention in the kidney are under studied and poorly understood. To date attachment via Randall's plaque is the only widely accepted theory in this regard, which is best described in idiopathic calcium oxalate stone formers. Brushite stone formers are known...... to have distinct papillary morphology relative to calcium oxalate stone formers. As such we sought to determine whether stone attachment mechanisms in such patients may be similarly unique. MATERIALS AND METHODS: Patients undergoing percutaneous and or ureteroscopic procedures for stone removal consented...... to endoscopic renal papillary examination and individual stone collection. Each removed stone was processed using micro computerized tomography to assess the 3-dimensional microstructure and the minerals contained, and search for common structural features indicative of novel mechanisms of early growth...

  2. Shock Wave Lithotripsy in Ureteral Stones: Evaluation of Patient and Stone Related Predictive Factors

    Directory of Open Access Journals (Sweden)

    Ozgur Yazici

    2015-08-01

    Full Text Available ABSTRACTPurpose:To evaluate the patient and stone related factors which may influence the final outcome of SWL in the management of ureteral stones.Materials and Methods:Between October 2011 and October 2013, a total of 204 adult patients undergoing SWL for single ureteral stone sizing 5 to 15 mm were included into the study program. The impact of both patient (age, sex, BMI, and stone related factors (laterality, location, longest diameter and density as CT HU along with BUN and lastly SSD (skin to stone distance on fragmentation were analysed by univariate and multivariate analyses. Results: Stone free rates for proximal and distal ureteral stones were 68.8% and 72.7%, respectively with no statistically significant difference between two groups (p=0.7. According to univariate and multivariate analyses, while higher BMI (mean: 26.8 and 28.1, p=0.048 and stone density values (mean: 702 HU and 930 HU, p<0.0001 were detected as statistically significant independent predictors of treatment failure for proximal ureteral stones, the only statistically significant predicting parameter for the success rates of SWL in distal ureteral stones was the higher SSD value (median: 114 and 90, p=0.012.Conclusions:Our findings have clearly shown that while higher BMI and increased stone attenuation values detected by NCCT were significant factors influencing the final outcome of SWL treatment in proximal ureteral stones; opposite to the literature, high SSD was the only independent predictor of success for the SWL treatment of distal ureteral stones.

  3. Mammography: an update of the EUSOBI recommendations on information for women

    OpenAIRE

    Sardanelli, Francesco; Fallenberg, Eva M.; Clauser, Paola; Trimboli, Rubina M.; Camps-Herrero, Julia; Helbich, Thomas H.; Forrai, Gabor

    2016-01-01

    Abstract This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a sma...

  4. Effect of crushing temperature on virgin olive oil quality and composition

    Directory of Open Access Journals (Sweden)

    Ö. Kula

    2018-03-01

    Full Text Available The objective of the current study was to assess the influence of a modified crushing process and kneading operation on the quality parameters, volatile compounds, and the fatty acid and sterol profiles of virgin olive oil from the Edremit yaglik variety. In the study, olive oil samples were produced in two different processes. The first one was produced without malaxation and the second one was produced with the malaxing process. During crushing, the effect of different temperatures was tested. The results demonstrate that different crushing temperatures generally did not affect the amount of free fatty acids, or peroxide value. Total phenol contents were positively affected by the additional malaxation process. Fatty acids and sterol composition were not significantly altered at different crushing temperatures or during the subsequent malaxation application. PCA enabled a clear classification of the oils obtained from different processing techniques.

  5. Physical, mechanical and thermal properties of Crushed Sand Concrete containing Rubber Waste

    Directory of Open Access Journals (Sweden)

    Mohamed Guendouz

    2018-01-01

    Full Text Available Over the past twenty years, the rubber wastes are an important part of municipal solid waste. This work focuses on the recycling of rubber waste, specifically rubber waste of used shoes discharged into the nature and added in the mass of crushed sand concrete with percentage (10%, 20%, 30% and 40%. The physical (workability, fresh density, mechanical (compressive and flexural strength and thermal (thermal conductivity of different crushed sand concrete made are analyzed and compared to the respective controls. The use of rubber waste in crushed sand concrete contributes to reduce the bulk density and performance of sand concrete. Nevertheless, the use of rubber aggregate leads to a significant reduction in thermal conductivity, which improves the thermal insulation of crushed sand concrete.

  6. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study.

    Science.gov (United States)

    Rafferty, Elizabeth A; Park, Jeong Mi; Philpotts, Liane E; Poplack, Steven P; Sumkin, Jules H; Halpern, Elkan F; Niklason, Loren T

    2014-02-01

    The purpose of this study was to compare two methods of combining tomosynthesis with digital mammography by assessing diagnostic accuracy and recall rates for digital mammography alone and digital mammography combined with one-view tomosynthesis and two-view tomosynthesis. Three hundred ten cases including biopsy-proven malignancies (51), biopsy-proven benign findings (47), recalled screening cases (138), and negative screening cases (74) were reviewed by 15 radiologists sequentially using digital mammography, adding one-view tomosynthesis, and then two-view tomosynthesis. Cases were assessed for recall and assigned a BI-RADS score and probability of malignancy for each imaging method. Diagnostic accuracy was assessed using receiver operating characteristic (ROC) analysis. Screening recall rates were compared using pooled logistical regression analysis. A p value of tomosynthesis, and DM plus two-view tomosynthesis was 0.828, 0.864, and 0.895, respectively. Both one-view and two-view tomosynthesis plus DM were significantly better than DM alone (Δ AUCs 0.036 [p = 0.009] and 0.068 [p tomosynthesis, and DM plus two-view tomosynthesis were 44.2%, 27.2%, and 24.0%, respectively. Combined with DM, one-view and two-view tomosynthesis both showed significantly lower noncancer recall rates than digital mammography alone (p tomosynthesis showed a significantly lower recall rate than digital mammography with one-view tomosynthesis (p tomosynthesis compared with digital mammography alone. Compared with digital mammography, diagnostic sensitivity for invasive cancers increased with the addition of both one-view (Δ12.0%, p tomosynthesis. The addition of one-view tomosynthesis to conventional digital mammography improved diagnostic accuracy and reduced the recall rate; however, the addition of two-view tomosynthesis provided twice the performance gain in diagnostic accuracy while further reducing the recall rate.

  7. Evaluation of constitutive models for crushed salt

    International Nuclear Information System (INIS)

    Callahan, G.D.; Loken, M.C.; Hurtado, L.D.; Hansen, F.D.

    1996-01-01

    Three constitutive models are recommended as candidates for describing the deformation of crushed salt. These models are generalized to three-dimensional states of stress to include the effects of mean and deviatoric stress and modified to include effects of temperature, grain size, and moisture content. A database including hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant (WIPP) and southeastern New Mexico salt is used to determine material parameters for the models. To evaluate the capability of the models, parameter values obtained from fitting the complete database are used to predict the individual tests. Finite element calculations of a WIPP shaft with emplaced crushed salt demonstrate the model predictions

  8. Reducing the startup time of aerobic granular sludge reactors through seeding floccular sludge with crushed aerobic granules.

    Science.gov (United States)

    Pijuan, Maite; Werner, Ursula; Yuan, Zhiguo

    2011-10-15

    One of the main challenging issues for the aerobic granular sludge technology is the long startup time when dealing with real wastewaters. This study presents a novel strategy to reduce the time required for granulation while ensuring a high level of nutrient removal. This new approach consists of seeding the reactor with a mixture of crushed aerobic granules and floccular sludge. The effectiveness of the strategy was demonstrated using abattoir wastewater, containing nitrogen and phosphorus at approximately 250 mgN/L and 30 mgP/L, respectively. Seven different mixtures of crushed granules and floccular sludge at granular sludge fractions (w/w in dry mass) of 0%, 5%, 10%, 15%, 25%, 30% and 50% were used to start eight granulation processes. The granulation time (defined as the time when the 10th percentile bacterial aggregate size is larger than 200 μm) displayed a strong dependency on the fraction of granular sludge. The shortest granulation time of 18 days was obtained with 50% crushed granules, in comparison with 133 days with 5% crushed granules. Full granulation was not achieved in the two trials without seeding with crushed granules. In contrast to the 100% floccular sludge cases, where a substantial loss of biomass occurred during granulation, the biomass concentration in all other trails did not decrease during granulation. This allowed that good nitrogen removal was maintained in all the reactors during the granulation process. However, enhanced biological phosphorus removal was achieved in only one of the eight trials. This was likely due to the temporary accumulation of nitrite, a strong inhibitor of polyphosphate accumulating organisms. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Control of quality in mammography

    International Nuclear Information System (INIS)

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  10. Understanding women's mammography intentions: a theory-based investigation.

    Science.gov (United States)

    Naito, Mikako; O'Callaghan, Frances V; Morrissey, Shirley

    2009-01-01

    The present study compared the utility of two models (the Theory of Planned Behavior and Protection Motivation Theory) in identifying factors associated with intentions to undertake screening mammography, before and after an intervention. The comparison was made between the unique components of the two models. The effect of including implementation intentions was also investigated. Two hundred and fifty-one women aged 37 to 69 years completed questionnaires at baseline and following the delivery of a standard (control) or a protection motivation theory-based informational intervention. Hierarchical multiple regressions indicated that theory of planned behavior variables were associated with mammography intentions. Results also showed that inclusion of implementation intention in the model significantly increased the association with mammography intentions. The findings suggest that future interventions aiming to increase screening mammography participation should focus on the theory of planned behavior variables and that implementation intention should also be targeted.

  11. The effect of motorcycle helmet fit on estimating head impact kinematics from residual liner crush.

    Science.gov (United States)

    Bonin, Stephanie J; Gardiner, John C; Onar-Thomas, Arzu; Asfour, Shihab S; Siegmund, Gunter P

    2017-09-01

    Proper helmet fit is important for optimizing head protection during an impact, yet many motorcyclists wear helmets that do not properly fit their heads. The goals of this study are i) to quantify how a mismatch in headform size and motorcycle helmet size affects headform peak acceleration and head injury criteria (HIC), and ii) to determine if peak acceleration, HIC, and impact speed can be estimated from the foam liner's maximum residual crush depth or residual crush volume. Shorty-style helmets (4 sizes of a single model) were tested on instrumented headforms (4 sizes) during linear impacts between 2.0 and 10.5m/s to the forehead region. Helmets were CT scanned to quantify residual crush depth and volume. Separate linear regression models were used to quantify how the response variables (peak acceleration (g), HIC, and impact speed (m/s)) were related to the predictor variables (maximum crush depth (mm), crush volume (cm 3 ), and the difference in circumference between the helmet and headform (cm)). Overall, we found that increasingly oversized helmets reduced peak headform acceleration and HIC for a given impact speed for maximum residual crush depths less than 7.9mm and residual crush volume less than 40cm 3 . Below these levels of residual crush, we found that peak headform acceleration, HIC, and impact speed can be estimated from a helmet's residual crush. Above these crush thresholds, large variations in headform kinematics are present, possibly related to densification of the foam liner during the impact. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Cancer of the breast: induction by radiation and role of mammography

    Energy Technology Data Exchange (ETDEWEB)

    Simon, N

    1977-10-01

    Conflict in the management of cancer of the breast exists. Diagnosis by x-ray mammography provides early effective treatment, but x-ray exposure to the breast is cancerogenic. Prudence requires the use of low dose x-rays in mammography, and limits the use of x-ray mammography in the young. Guide lines for the indications for mammography are changing, and large scale population exposure to radiation should await results of demonstration projects in the United States.

  13. Radiology Residents' Performance in Screening Mammography Interpretation

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Lyou, Chae Yeon

    2013-01-01

    To evaluate radiology residents' performance in screening mammography interpretation and to analyze the factors affecting performance. We enrolled 203 residents from 21 institutions and performed mammography interpretation tests. Between the trainee and non-trainee groups, we compared the interpretation score, recall rate, sensitivity, positive predictive value (PPV) and false-positive rate (FPR). We estimated the training effect using the score differences between trainee and non-trainee groups. We analyzed the factors affecting performance between training-effective and non-effective groups. Trainees were superior to non-trainees regarding interpretation score (43.1 vs. 37.1), recall rate (11.0 vs. 15.5%), sensitivity (83.6 vs. 72.0%), PPV (53.0 vs. 32.4%) and FPR (13.5 vs. 25.5). The longer the training period, the better were the interpretation score, recall rate, sensitivity, PPV and FPR (rho = 0.486, -0.375, 0.343, 0.504, -0.446, respectively). The training affected an increase by an average of 6 points; however, 31.6% of institutions showed no effect. A difference was noted in the volume of mammography interpretation during a month (594.0 vs. 476.9) and dedication of breast staff (61.5 vs. 0%) between training-effective and non-effective groups. Trainees showed better performance in mammography interpretation compared to non-trainees. Moreover, performance was correlated with the training period. The factors affecting performance were the volume of mammography interpretation and the dedication of the breast staff.

  14. Exposure and roentgen-area-product in xeromammography and conventional mammography

    Energy Technology Data Exchange (ETDEWEB)

    Baxt, J H; Bushong, S C; Glaze, S; Kothari, S [Baylor Univ., Houston, Tex. (USA). Coll. of Medicine

    1976-01-01

    X-ray mammography is assuming increasing importance in the early detection of breast cancer. The principal disadvantage to conventional mammography is high patient dose. Xeromammography offers three advantages over conventional mammography: (a) lower patient dose, (b) better image quality and (c) no special mammography tube required. A transmission ionization chamber and thermoluminescent dosimeters were used to measure the roentgen-area-product and the exposure for three view examination. Average roentgen-area-product values of 6500 and 4200 R-cm/sup 2/ were observed for conventional mammography and xeromammography respectively. The medial surface of the breast received the highest radiation exposure for both types of examinations and this was shown to be 11.5 and 5.1 R respectively. Omission of the axillary view from the examination reduces the patient dose in both types by approximately 60 %.

  15. Does health status influence intention regarding screening mammography?

    International Nuclear Information System (INIS)

    Park, Keeho; Park, Jong-Hyock; Park, Jae-Hyun; Kim, Hui-Jeong; Park, Bo-Yoon

    2010-01-01

    We analyzed information surveyed from a community-based sample of Korean women older than 40 years of age to understand the relationships between health status and screening behavior. In a cross-sectional population-based study, a two-stage, geographically stratified household-based sampling design was used for assembly of a probability sample of women aged 40-69 years living in Gunpo in Korea, resulting in a total sample size of 503 women. The primary outcome variable for this analysis was the respondent's intention to obtain a mammogram. Predictor variables included health status and other factors known to influence the use of cancer screening, such as age, education, income, marital status and the presence of co-morbid illnesses. Health status was assessed by using the EuroQol (EQ-5D). The median EQ visual analogue scale score was 75.0, ranging from 20 to 100. In bivariate analyses, the percentage of women reporting to have intention toward mammography use decreased with worsening health status. Women who had problems with mobility or anxiety/depression showed lower intention to undergo future screening mammography. Multivariate logistic regression confirmed that health status was significantly associated with intention toward mammography use. Anxiety or depression was an independent predictor of future screening mammography use. Health status is significantly associated with intention regarding screening mammography use. Physicians or other health professionals should be aware that health status is an important component for health promotion, and should pay more attention to clients' possible vulnerability in screening mammography use due to their poor health status. (author)

  16. The accuracy of digital breast tomosynthesis compared with coned compression magnification mammography in the assessment of abnormalities found on mammography

    International Nuclear Information System (INIS)

    Morel, J.C.; Iqbal, A.; Wasan, R.K.; Peacock, C.; Evans, D.R.; Rahim, R.; Goligher, J.; Michell, M.J.

    2014-01-01

    Aim: To compare the diagnostic accuracy of the digital breast tomosynthesis (DBT) with coned compression magnification mammography (CCMM). Materials and methods: The study design included two reading sessions completed by seven experienced radiologists. In the first session, all readers read bilateral standard two-view mammograms and a CCMM view of the lesion before giving a combined score for assessment. In the second session, readers read bilateral standard two-view mammograms plus one-view DBT. The two reading sessions of the experiment were separated by at least 2 weeks to reduce the chance of reader memory of the images read in the previous session from influencing the performance in the subsequent session. Results: Three hundred and fifty-four lesions were assessed and receiver-operative characteristic (ROC) analysis was used to evaluate the difference between the two modes. For standard two-view mammography plus CCMM, the area under the curve (AUC) was 0.87 [95% confidence interval (CI): 0.83–0.91] and for standard two-view mammography plus DBT the AUC was 0.93 (95% CI: 0.91–0.95). The difference between the AUCs was 0.06 with p-value of 0.0014. Conclusion: Two-view mammography with one-view DBT showed significantly improved accuracy compared to two-view mammography and CCMM in the assessment of mammographic abnormalities. These results show that DBT can be used effectively in the further evaluation of mammographic abnormalities found at screening and in symptomatic diagnostic practice. - Highlights: • Diagnostic accuracy of magnification mammography and digital breast tomosynthesis. • There is statistical difference between CCMM and DBT. • DBT has a role in evaluating mammographic abnormalities

  17. 49 CFR 587.15 - Verification of aluminum honeycomb crush strength.

    Science.gov (United States)

    2010-10-01

    ... analog or digital form for each sample tested. If analog data are collected, a means of converting the data to digital data must be made available. All digital data are collected at a rate consistent with... all data prior to 6.4 mm (0.25 in) of crush and after 16.5 mm (0.65 in) of crush. Divide the remaining...

  18. Retrograde intrarenal stone surgery for extracorporeal shock-wave lithotripsy-resistant kidney stones

    DEFF Research Database (Denmark)

    Jung, Helene; Nørby, Bettina; Osther, Palle Jörn

    2006-01-01

    OBJECTIVE: The newer flexible ureteroscopes, 150-200-microm holmium YAG laser fibres and superflexible Dormia baskets have made it possible to reach and treat stones in all parts of the kidney. The object of this evaluation was to study the outcome of retrograde intrarenal stone surgery (RIRS......) for extracorporeal shock-wave lithotripsy (ESWL)-resistant kidney stones. MATERIAL AND METHODS: A total of 38 consecutive patients (18 males, 20 females) participated in the study. All patients had undergone ESWL prior to RIRS without success. In all cases the stones could be reached with the endoscope. Calculi...... ranged in size from 3 to 20 mm (mean 9 mm). In 32 cases the stones were fragmented using a holmium YAG laser and in six the stones could be extracted using zero-tip Dormia baskets without fragmentation. Sixteen patients had lower calyceal calculi and eight had an abnormal anatomy of the upper urinary...

  19. Dual-energy mammography: simulation studies

    International Nuclear Information System (INIS)

    Bliznakova, K; Kolitsi, Z; Pallikarakis, N

    2006-01-01

    This paper presents a mammography simulator and demonstrates its applicability in feasibility studies in dual-energy (DE) subtraction mammography. This mammography simulator is an evolution of a previously presented x-ray imaging simulation system, which has been extended with new functionalities that are specific for DE simulations. The new features include incident exposure and dose calculations, the implementation of a DE subtraction algorithm as well as amendments to the detector and source modelling. The system was then verified by simulating experiments and comparing their results against published data. The simulator was used to carry out a feasibility study of the applicability of DE techniques in mammography, and more precisely to examine whether this modality could result in better visualization and detection of microcalcifications. Investigations were carried out using a 3D breast software phantom of average thickness, monoenergetic and polyenergetic beam spectra and various detector configurations. Dual-shot techniques were simulated. Results showed the advantage of using monoenergetic in comparison with polyenergetic beams. Optimization studies with monochromatic sources were carried out to obtain the optimal low and high incident energies, based on the assessment of the figure of merit of the simulated microcalcifications in the subtracted images. The results of the simulation study with the optimal energies demonstrated that the use of the DE technique can improve visualization and increase detectability, allowing identification of microcalcifications of sizes as small as 200 μm. The quantitative results are also verified by means of a visual inspection of the synthetic images

  20. Factors affecting stone-free rate and complications of percutaneous nephrolithotomy for treatment of staghorn stone.

    Science.gov (United States)

    el-Nahas, Ahmed R; Eraky, Ibrahim; Shokeir, Ahmed A; Shoma, Ahmed M; el-Assmy, Ahmed M; el-Tabey, Nasr A; Soliman, Shady; Elshal, Ahmed M; el-Kappany, Hamdy A; el-Kenawy, Mahmoud R

    2012-06-01

    To determine factors affecting the stone-free rate and complications of percutaneous nephrolithotomy (PNL) for treatment of staghorn stones. The computerized database of patients who underwent PNL for treatment of staghorn stones between January 2003 and January 2011 was reviewed. All perioperative complications were recorded and classified according to modified Clavien classification system. The stone-free rate was evaluated with low-dose noncontrast computed tomography (CT). Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free and complication rates. The study included 241 patients (125 male and 116 female) with a mean age of 48.7 ±14.3 years. All patients underwent 251 PNL (10 patients had bilateral stones). The stone-free rate of PNL monotherapy was 56% (142 procedures). At 3 months, the stone-free rate increased to 73% (183 kidneys) after shock wave lithotripsy. Independent risk factors for residual stones were complete staghorn stone and presence of secondary calyceal stones (relative risks were 2.2 and 3.1, respectively). The complication rate was 27% (68 PNL). Independent risk factors for development of complications were performance of the procedure by urologists other than experienced endourologist and positive preoperative urine culture (relative risks were 2.2 and 2.1, respectively). Factors affecting the incidence of residual stones after PNL are complete staghorn stones and the presence of secondary calyceal stones. Complications are significantly high if PNL is not performed by an experienced endourologist or if preoperative urine culture is positive. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Thermal conductivity of crushed salt

    International Nuclear Information System (INIS)

    Kuehn, K.

    Heat transfer through an annular space filled with crushed salt depends primarily on the thermal conductivity, lambda, of the material. This report gives a formula with which lambda can be computed. The formula includes two quantities that can be influenced through screening of the salt smalls: the porosity, psi, and the fraction, alpha, of the more highly resistive heat-flow paths. The report computes and presents graphically the thermal conductivities for various values of psi and alpha. Heat-transfer properties are computed and compared for an annular space filled with crushed salt and for an air gap. The comparison shows that the properties of the annular space are larger only up to a certain temperature, because the properties of the air gap increase exponentially while those f the annular space increase only in an approximately linear way. Experimental results from Project Salt Vault in the U.S. are in good agreement with the calculations performed. Trials in Temperature Experimental Field 2 at the Asse II salt mine will provide an additional check on the calculations. 3 figures, 3 tables

  2. Quality assurance in mammography

    International Nuclear Information System (INIS)

    Fosmark, H.; Olerud, H.M.

    1992-01-01

    Guidelines in mammography are given, including competence of staff, performance of equipment and quality control procedures. The purpose of the guidelines is to ensure optimum diagnostic quality. 5 refs

  3. Digital mammography: what do we and what don't we know?

    International Nuclear Information System (INIS)

    Bick, Ulrich; Diekmann, Felix

    2007-01-01

    High-quality full-field digital mammography has been available now for several years and is increasingly used for both diagnostic and screening mammography. A number of different detector technologies exist, which all have their specific advantages and disadvantages. Diagnostic accuracy of digital mammography has been shown to be at least equivalent to film-screen mammography in a general screening population. Digital mammography is superior to screen-film mammography in younger women with dense breasts due to its ability to selectively optimize contrast in areas of dense parenchyma. This advantage is especially important in women with a genetic predisposition for breast cancer, where intensified early detection programs may have to start from 25 to 30 years of age. Tailored image processing and computer-aided diagnosis hold the potential to further improve the early detection of breast cancer. However, at present no consensus exists among radiologists on which processing is optimal for digital mammograms. Image processing may also vary significantly among vendors with so far limited interoperability. This review aims to summarize the available information regarding the impact of digital mammography on workflow and breast cancer diagnosis. (orig.)

  4. The Future of Contrast-Enhanced Mammography.

    Science.gov (United States)

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  5. Kidney stones - self-care

    Science.gov (United States)

    ... self-care; Nephrolithiasis and self-care; Stones and kidney - self-care; Calcium stones and self-care; Oxalate ... provider or the hospital because you have a kidney stone. You will need to take self-care ...

  6. Systemic sclerosis in a stone cutter

    Directory of Open Access Journals (Sweden)

    Khanna N

    1997-01-01

    Full Text Available Several occupational hazards especially exposure to silica have been implicated as eliciting factors for the development of scleroderma-like disorders. We here report a case of manual stone-cutter who developed progressive scleroderma, interstitial lung disease and decreased oesophageal motility after several years of exposure to silica dust.

  7. Dual-energy contrast-enhanced digital mammography: initial clinical results

    International Nuclear Information System (INIS)

    Dromain, Clarisse; Thibault, Fabienne; Tardivon, Anne; Muller, Serge; Rimareix, Francoise; Delaloge, Suzette; Balleyguier, Corinne

    2011-01-01

    To assess the diagnostic accuracy of Dual-Energy Contrast-Enhanced Digital Mammography (CEDM) as an adjunct to mammography (MX) versus MX alone and versus mammography plus ultrasound (US). 120 women with 142 suspect findings on MX and/or US underwent CEDM. A pair of low- and high-energy images was acquired using a modified full-field digital mammography system. Exposures were taken in MLO at 2 min and in CC at 4 min after the injection of 1.5 ml/kg of an iodinated contrast agent. One reader evaluated MX, US and CEDM images during 2 sessions 1 month apart. Sensitivity, specificity, and area under the ROC curve were estimated. The results from pathology and follow-up identified 62 benign and 80 malignant lesions. Areas under the ROC curves were significantly superior for MX+CEDM than it was for MX alone and for MX+US using BI-RADS. Sensitivity was higher for MX+CEDM than it was for MX (93% vs. 78%; p < 0.001) with no loss in specificity. The lesion size was closer to the histological size for CEDM. All 23 multifocal lesions were correctly detected by MX+CEDM vs. 16 and 15 lesions by MX and US respectively. Initial clinical results show that CEDM has better diagnostic accuracy than mammography alone and mammography+ultrasound. (orig.)

  8. Lessons from a Stone Farm

    Science.gov (United States)

    Kavanagh, John P.; Rao, P. Nagaraj

    2007-04-01

    The stone farm is a system for measuring macroscopic stone growth of 12 calcium stones simultaneously. It is based on mixed suspension, mixed product removal continuous crystallization principles and the stones are grown continuously for about 500 hours or more. The growth of the stones follows a surface area dependent pattern and the growth rate constants are very similar irrespective of whether the stating materials are fragments of human stone or pieces of marble chip. Increasing citrate from 2mM to 6mM caused a significant growth inhibition which persisted in the presence of urinary macromolecules. Phytate was a very effective inhibitor (about 50% at sub-μM concentrations) but the effective concentration was increased by an order of magnitude in the presence of urinary macromolecules. The effective concentration for inhibition in a crystallization assay was a further two orders of magnitude higher. Urinary macromolecules or almost whole urine were also strongly inhibitory although neither human serum albumin nor bovine mucin had any great effect. The relationship between the size distribution of crystals in suspension and the stone enlargement rate suggests that the primary enlargement mechanism for these in vitro stones is through aggregation. The stone farm is a powerful tool with which to study crystallization inhibitors in a new light. Some differences between inhibition of crystallization and inhibition of stone growth have emerged and we have obtained quantitative evidence on the mechanism of stone enlargement in vitro. Our findings suggest that the interface between crystals in suspension and the stone surface is the key to controlling stone enlargement.

  9. Clay modified crushed salt for shaft sealing elements. Material optimization and evaluation in field tests

    Energy Technology Data Exchange (ETDEWEB)

    Glaubach, Uwe; Hofmann, Martin; Gruner, Matthias; Kudla, Wolfram [TU Bergakademie Freiberg (Germany). Inst. of Mining and Special Civil Engineering

    2015-07-01

    Salt-based materials are intended to use for backfill and sealing systems in geotechnical barriers in underground HLW-repositories. Due to the creep of the saliniferous host rock, the salt backfill will be compacted during several hundreds or thousands years of operation to a minimum of porosity resp. permeability. To raise the sealing potential of a salt-based backfill, the porosity after construction should be minimized by optimal material performance and compaction performance. A procedure to optimize the grain size distribution of crushed salt and its water and clay content is described. The optimized salt fraction gets a better compaction behavior than straight mine-run salt. The addition of a filler-like material (e.g. Friedland Clay Powder) reduces the total porosity and permeability. Backfill columns made from crushed salt and clay probably include an instant sealing function.

  10. Characterization of kidney stones using NAA and other techniques

    International Nuclear Information System (INIS)

    Srivastava, A.; Bhardwaj, S.; Vashisht, B.; Swain, K.K.; Ajith, Nicy; Chavan, T.; Wagh, D.N.; Reddy, A.V.R.; Mete, U.; Acharya, R.

    2014-01-01

    Six kidney stone samples were collected from patients treated in the Advance Urology Centre of PGIMER, Chandigarh. The samples were characterized using neutron activation analysis (NAA), Energy dispersive X-ray fluorescence (EDXRF), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) techniques. For NAA, samples were irradiated in Tray rod facility of Dhruva reactor, Mumbai. Radioactive assay was carried out using high purity germanium detector coupled to 8k channel analyzer. The elements determined in the samples by NAA are Zn, Sr, Co, Fe, Cr, Sc, Se and Th. ED-XRF was used for quantification of Ca. The concentrations of trace elements like Zn, Sr, Fe and Cr were found to be lower in uric acid composite stones as compared to calcium based stones. (author)

  11. Combination of one-view digital breast tomosynthesis with one-view digital mammography versus standard two-view digital mammography: per lesion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gennaro, Gisella; Bezzon, Elisabetta; Pescarini, Luigi; Polico, Ilaria; Proietti, Alessandro; Baldan, Enrica; Pomerri, Fabio; Muzzio, Pier Carlo [Veneto Institute of Oncology (IRCCS), Padua (Italy); Hendrick, R.E. [University of Colorado-Denver, Department of Radiology, School of Medicine, Aurora, CO (United States); Toledano, Alicia [Biostatistics Consulting, LLC, Kensington, MD (United States); Paquelet, Jean R. [Advanced Medical Imaging Consultants, Fort Collins, CO (United States); Breast Imaging, McKee Medical Center, Loveland, CO (United States); Chersevani, Roberta [Private Medical Practice, Gorizia (Italy); Di Maggio, Cosimo [Private Medical Practice, Padua (Italy); La Grassa, Manuela [Department of Radiology, Oncological Reference Center (IRCCS), Aviano (Italy)

    2013-08-15

    To evaluate the clinical value of combining one-view mammography (cranio-caudal, CC) with the complementary view tomosynthesis (mediolateral-oblique, MLO) in comparison to standard two-view mammography (MX) in terms of both lesion detection and characterization. A free-response receiver operating characteristic (FROC) experiment was conducted independently by six breast radiologists, obtaining data from 463 breasts of 250 patients. Differences in mean lesion detection fraction (LDF) and mean lesion characterization fraction (LCF) were analysed by analysis of variance (ANOVA) to compare clinical performance of the combination of techniques to standard two-view digital mammography. The 463 cases (breasts) reviewed included 258 with one to three lesions each, and 205 with no lesions. The 258 cases with lesions included 77 cancers in 68 breasts and 271 benign lesions to give a total of 348 proven lesions. The combination, DBT{sub (MLO)}+MX{sub (CC)}, was superior to MX (CC+MLO) in both lesion detection (LDF) and lesion characterization (LCF) overall and for benign lesions. DBT{sub (MLO)}+MX{sub (CC)} was non-inferior to two-view MX for malignant lesions. This study shows that readers' capabilities in detecting and characterizing breast lesions are improved by combining single-view digital breast tomosynthesis and single-view mammography compared to two-view digital mammography. (orig.)

  12. Current perspectives on indications and limitations of mammography

    International Nuclear Information System (INIS)

    Pope, T.L. Jr.

    1983-01-01

    Women have a 7 percent natural lifetime risk of developing breast cancer, which is the leading cause of death in women aged 40 to 50 years. Most data suggest that the earlier the disease is diagnosed, the better the chance for cure. Women with ''minimal breast cancer'' have an actuarial 20-year survival rate of 93.2 percent. The majority of these breast cancers are diagnosed by mammography. The radiation doses from this technique have been dramatically decreased over the last ten years to about 0.1 to 0.6 rads per study. The two largest breast cancer screening studies, the Health Insurance Plan of Greater New York and the Breast Cancer Detection Demonstration Project, have shown conclusively that women over 50 years old can benefit from annual mammography and that certain groups can benefit from mammography at close intervals before the age of 50 years. This article describes the development of mammography and outlines current perspectives on its indications and limitations

  13. Influence of the radiographer on the pain felt during mammography

    International Nuclear Information System (INIS)

    Goethem, M. van; Verslegers, I.; Biltjes, I.; De Schepper, A.; Mortelmans, D.; Bruyninckx, E.; Hove, E. Van

    2003-01-01

    Mammography is the only useful examination in screening for breast cancer. Mortality from breast cancer can be reduced if women go regularly for a screening mammography. Moreover, it is still the key examination in diagnosis of breast diseases and in the follow-up of patients treated for breast cancer. Pain with mammography can deter women from going for regular screening or follow-up; therefore, it is important to reduce pain experience or discomfort from mammography. In this study we evaluate the impact of the ''radiographer'' on the pain risk during mammography by analysing questionnaires filled in by women and radiographers. Study results reveal that the opinion of the radiographer, the information and communication during the examination and the number of years of experience are important factors in pain and discomfort experience. The attitude of the radiographer plays an important role in the pain experience. (orig.)

  14. Current status of mammography

    International Nuclear Information System (INIS)

    Crymes, J.E.

    1979-01-01

    Great progress has been made in recent years in the diagnosis and treatment of breast cancer; however, breast cancer continues to be the most common and lethal cancer in women today. Early diagnosis is essential in order for treatmet to be given before the tumor spreads beyond the breast. The radiation risks of mammography have been greatly reduced with the use of newer low-dose techniques, and the benefits of mammography have increased because of a better understanding of the natural history of breast cancer, as well as improved methods of treatment. Radiologists must continue to take an active role in the early diagnosis of breast cancer. Continued research is needed in order to improve screening methods and to develop newer, noninvasive techniques

  15. Lower Pole Calyceal Stone and Lithotripsy are Issues with Clearance Fact or Reality?

    Directory of Open Access Journals (Sweden)

    M. Hammad Ather

    2013-12-01

    Full Text Available The lower pole calyceal (LPC stone continues to be an enigma. The complex anatomy of the lower pole collecting system, along with other factors like acute pelvi calyceal angle and narrow and long infundibulum, are some of the complicating factors affecting stone clearance. There have been many studies assessing the impact of collecting system anatomy and most conclude that the complex anatomy of the lower pole collecting system does impact the overall stone-free rate.

  16. Quality control of physician-performed mammography. Importance of original attempts to improve quality

    International Nuclear Information System (INIS)

    Nakayama, Takashi; Terada, Hiroshi; Kotsuma, Yoshikazu

    2006-01-01

    In order to perform effective breast cancer screening with mammography, family doctors should be encouraged to participate. At institutions without specific radiology technicians, physicians themselves are required to perform mammography and operate the equipment, otherwise it is difficult to consistently obtain good-quality mammograms. Our institutions have been given a grade ''A'' evaluation by the Central Committee for Quality Control of Mammographic Screening (CCQCMS), due largely to our own efforts and promotion. Here we report our experience in solving a number of problems that occurred during the establishment of our system. We used the SEPIO standard mammography apparatus with a MD-100/CM-H screen/filter system, and developed films using a TCX-202 automatic film processor. Problems due to asymmetry of the bilateral breasts and lack of retroglandular fat tissue space and inframammary folds seen on our initial mammograms were overcome by placing marks at the postion of the AEC sensor, and at both ends and the center of the film on a bucky table. We simplified the markers by removing several complicated ones. We tried to rectify areas of the image that were obscured due to the difference in size between the inside of the cassette and the screen. Physicians and a radiology technician attended a mammography study course once weekly, and attempted to improve the quality of mammograms and our reading ability by obtaining advice from members of the CCQCMS. Manufacturers responded with considerable delay to our attempt to overcome the troublesome appearance of numerous microcalfication-like artifact shadows caused by screens. In conclusion, in order to perform effective breast cancer screening with mammography, we must obtain mammograms of good quality, for which it is necessary to always try to seek new ways of improving. At the same time, manufacturers need to respond quickly to queries and problems related to quality control. (author)

  17. Evaluation of the performance characteristic for mammography by using edge device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Choi, Jwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, The Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [Dept. of Medical Science, The Soonchunhyang University, Asan (Korea, Republic of); Lee, Eul Kyu [Dept. of Radiology, Inje Paik University Hospital Jeo-dong, Seoul (Korea, Republic of); Son, Soon Yong [Dept. of Radiological Technology, The Wonkwang Health Science University, Iksan (Korea, Republic of); Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, The Shingu University, Sungnam (Korea, Republic of)

    2016-09-15

    The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of dimensions tomo and lorad selenia mammography were maintained at 10 mm-1 and NPS and DQE including the low nyquist frequency indicated to 6.0 mm-1. Therefore, regularly QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

  18. Study of renal stones complications in 200 patients in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Hamid Noshad

    2014-11-01

    Full Text Available Introduction: Urinary stones are the third most common disease of the urinary. Renal stones may lead to some preventable complications. This study was designed to investigation and prediction of these complications. Methods: In this cross-sectional study, 200 patients with kidney stones were enrolled. Kidney stone was confirmed and proven in all patients referred to Sina and Shaikh Al-Rais clinics. Their demographic characteristics like gender, age, stone number, stone type, renal failure and bio-chemistry data were evaluated. Results: Of 200 patients, 130 cases (65.0% were male and 70 cases (35.0% were female. The mean age of patients was 41.30 ± 16.06 years. Type of stone was (when evaluation was possible was mixed (11.5%. However, the type of stone was not analyzed in 112 cases (56.0%. Among complications, recurrent infection was seen (16.0%, and staghorn stones were seen in 2.5% of patients. Dialysis was positive in 3 patients (1.5%. History of surgery was positive in 3 patients (1.5%. Extracorporeal shock wave lithotripsy (ESWL history was positive in 8%. In evaluated patients, the mean level of calcium was 8.83 ± 0.27, phosphorus was 4.60 ± 0.33, parathyroid hormone (PTH was 35.20 ± 14.22, uric acid was 4.98 ± 1.57, creatinine was 1.38 ± 1.02 and blood urea nitrogen level was 16.69 ± 11.54 mg/dl. Staghorn stones are significantly associated with progression to renal failure and subsequent complications such as hemodialysis (P = 0.001, surgery (P = 0.001. Recurrent infection was more frequent in calcium-containing stones (P = 0.001 and ESWL undergoing patients (P = 0.030. Stone numbers were more than 3 in hemodialyzed (HD patients (P = 0.001. Uric acid stones were more seen in HD patients (P = 0.170. Conclusion: According to results hemodialysis and recurrent infections are seen in patients with renal stones, and they may be detected in earlier with close periodic follow-up.

  19. Crush Can Behaviour as an Energy Absorber in a Frontal Impact

    International Nuclear Information System (INIS)

    Bhuyan, Atanu; Ganilova, Olga

    2012-01-01

    The work presented is devoted to the investigation of a state-of-the-art technological solution for the design of a crush-can characterized by optimal energy absorbing properties. The work is focused on the theoretical background of the square tubes, circular tubes and inverbucktube performance under impact with the purpose of design of a novel optimized structure. The main system under consideration is based on the patent US 2008/0185851 A1 and includes a base flange with elongated crush boxes and back straps for stabilization of the crush boxes with the purpose of improvement of the energy-absorbing functionality. The modelling of this system is carried out applying both a theoretical approach and finite element analysis concentrating on the energy absorbing abilities of the crumple zones. The optimization process is validated under dynamic and quasi-static loading conditions whilst considering various modes of deformation and stress distribution along the tubular components. Energy absorbing behaviour of the crush-cans is studied concentrating on their geometrical properties and their diamond or concertina modes of deformation. Moreover, structures made of different materials, steel, aluminium and polymer composites are considered for the material effect analysis and optimization through their combination. Optimization of the crush-can behaviour is done within the limits of the frontal impact scenario with the purpose of improvement of the structural performance in the Euro NCAP tests.

  20. Crush Can Behaviour as an Energy Absorber in a Frontal Impact

    Science.gov (United States)

    Bhuyan, Atanu; Ganilova, Olga

    2012-08-01

    The work presented is devoted to the investigation of a state-of-the-art technological solution for the design of a crush-can characterized by optimal energy absorbing properties. The work is focused on the theoretical background of the square tubes, circular tubes and inverbucktube performance under impact with the purpose of design of a novel optimized structure. The main system under consideration is based on the patent US 2008/0185851 A1 and includes a base flange with elongated crush boxes and back straps for stabilization of the crush boxes with the purpose of improvement of the energy-absorbing functionality. The modelling of this system is carried out applying both a theoretical approach and finite element analysis concentrating on the energy absorbing abilities of the crumple zones. The optimization process is validated under dynamic and quasi-static loading conditions whilst considering various modes of deformation and stress distribution along the tubular components. Energy absorbing behaviour of the crush-cans is studied concentrating on their geometrical properties and their diamond or concertina modes of deformation. Moreover, structures made of different materials, steel, aluminium and polymer composites are considered for the material effect analysis and optimization through their combination. Optimization of the crush-can behaviour is done within the limits of the frontal impact scenario with the purpose of improvement of the structural performance in the Euro NCAP tests.

  1. Readability assessment of internet-based patient education materials related to mammography for breast cancer screening.

    Science.gov (United States)

    AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil

    2015-03-01

    The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  2. Utilization of crushed clay brick in cellular concrete production

    Directory of Open Access Journals (Sweden)

    Ali A. Aliabdo

    2014-03-01

    Full Text Available The main objective of this research program is to study the effect of using crushed clay brick as an alternative aggregate in aerated concrete. Two series of mixtures were designed to investigate the physico-mechanical properties and micro-structural analysis of autoclave aerated concrete and foamed concrete, respectively. In each series, natural sand was replaced with crushed clay brick aggregate. In both series results showed a significant reduction in unit weight, thermal conductivity and sound attenuation coefficient while porosity has increased. Improvement on compressive strength of autoclave aerated concrete was observed at a percentage of 25% and 50% replacement, while in foamed concrete compressive strength gradually decreased by increasing crushed clay brick aggregate content. A comparatively uniform distribution of pore in case of foamed concrete with natural sand was observed by scanning electron microscope, while the pores were connected mostly and irregularly for mixes containing a percentage higher than 25% clay brick aggregate.

  3. Calibration procedures for mammography dosemeters in Poland

    International Nuclear Information System (INIS)

    Gwiazdowska, B.; Ulkowski, P.; Tolwinski, J.; Bulski, W.

    2002-01-01

    Breast cancer is the most frequent tumour in women and the effectiveness of the treatment depends dramatically on the early detection of the disease. That is the reason why in Poland the mammography control examinations are strongly supported by the Centre of Oncology. In Poland there are over 400 mammography units which account for about 300,000 examinations per year. An investigation performed by the Medical Physics Department of the Centre of Oncology in Warsaw at about 100 mammography facilities proved that in most cases the doses absorbed by the patients could be reduced without decrease of image quality. This is one of the reasons why the Polish Secondary Standard Dosimetry Laboratory (SSDL) dealing mainly with calibration of radiotherapy dosemeters is extending its activities and therefore new facilities and equipment adapted for calibration of mammographic dosemeters have been installed. The mammography dosimetry calibration equipment is permanently installed in the same laboratory room where the radiotherapy dosemeters are calibrated. A base of a mammography unit no longer in clinical use, together with its movable system has been adapted to handle ionization chamber holders. An X-ray tube with a 50 kV high frequency generator was also installed. The tube, a Varian type OEG-50-2, (designed for laboratory applications) with molybdenum anode of an anode angle 23,7 deg. and with a large focus, effective size approximately 5 mm 2 , has an inherent filtration of 0,25 mm beryllium. It is installed in a housing with 2mm lead shielding; a cone shaped beam is formed by a system of three collimators

  4. Pain during mammography: Implications for breast screening programmes

    International Nuclear Information System (INIS)

    Andrews, F.J.

    2001-01-01

    Pain experienced during mammography can deter women from attending for breast cancer screening. Review of the current literature on pain experienced during mammography reveals three main areas of interest: reports of the frequency of pain, identification of predictors of pain and strategies for responding to pain. Implications of this literature for breast screening programmes include the need for appropriate measurements of pain during mammography that are valid for screening populations, a further understanding of organizational factors involved in screening programmes that may be predictors of pain and for the development of valid strategies for responding to pain within breast screening programmes. Copyright (2001) Blackwell Science Pty Ltd

  5. Kidney stone erosion by micro scale hydrodynamic cavitation and consequent kidney stone treatment.

    Science.gov (United States)

    Perk, Osman Yavuz; Şeşen, Muhsincan; Gozuacik, Devrim; Koşar, Ali

    2012-09-01

    The objective of this study is to reveal the potential of micro scale hydrodynamic bubbly cavitation for the use of kidney stone treatment. Hydrodynamically generated cavitating bubbles were targeted to the surfaces of 18 kidney stone samples made of calcium oxalate, and their destructive effects were exploited in order to remove kidney stones in in vitro experiments. Phosphate buffered saline (PBS) solution was used as the working fluid under bubbly cavitating conditions in a 0.75 cm long micro probe of 147 μm inner diameter at 9790 kPa pressure. The surface of calcium oxalate type kidney stones were exposed to bubbly cavitation at room temperature for 5 to 30 min. The eroded kidney stones were visually analyzed with a high speed CCD camera and using SEM (scanning electron microscopy) techniques. The experiments showed that at a cavitation number of 0.017, hydrodynamic bubbly cavitation device could successfully erode stones with an erosion rate of 0.31 mg/min. It was also observed that the targeted application of the erosion with micro scale hydrodynamic cavitation may even cause the fracture of the kidney stones within a short time of 30 min. The proposed treatment method has proven to be an efficient instrument for destroying kidney stones.

  6. Hardware for mammography

    International Nuclear Information System (INIS)

    Rozhkova, N.I.; Chikirdin, Eh.G.; Ryudiger, Yu.G.; Kochetova, G.P.; Lisachenko, I.V.; Yakobs, O.Eh.

    2000-01-01

    The comparative studies on various visualization means, in particular, the intensifying screens and films with application of quantitative methods for determining small details on photographs, including measurements of corresponding exposures, absorbed doses and verification of conclusions through the analysis of clinical observations are carried out. It is shown, that technical equipment of the modern mammography room should include the X-ray mammographic apparatus, providing for the image high-quality by low dose loads with special film holders, meeting the mammography requirements, the corresponding X-ray film and the automatic photolaboratory process, provided by one and the same company. The quality of photographs under such conditions is guarantied, the defects and errors by the image interpretation are excluded. The modern computerized information technologies for work with medical images on the basic of creating new generations of diagnostic instrumentation with digital video channels and computerized working places dispose of many medical, technological, organizational and financial problems [ru

  7. The clinical use of mammography in the male; Klinische Relevanz der Mammographie beim Mann

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, E [Ulm Univ. (Germany). Abt. Radiologie; Mueller, M [Ulm Univ. (Germany). Abt. Radiologie; Vogel, J [Ulm Univ. (Germany). Abt. Radiologie; Klatt, S [Ulm Univ. (Germany). Abt. Innere Medizin I; Goerich, J [Ulm Univ. (Germany). Abt. Radiologie; Berger, H G [Ulm Univ. (Germany). Allgemeinchirurgische Abt.; Brambs, H J [Ulm Univ. (Germany). Abt. Radiologie

    1996-01-01

    During a period of four years 104 mammograms were performed in 89 men. Mastectomies were carried out on 23 men (group 1). 66 patients (group 2) were followed up clinically and in 15 patients serial mammograms were obtained. In group 1 there were 5 patients with bilateral gynaecomastia, 9 with unilateral gynaecomastia and two with pseudogynaecomastia and there were 7 patients with malignancies. In group 2 there were 46 patients with bilateral gynaecomastia and 10 patients with unilateral gynaecomastia. Pseudogynaecomastia was found in 25 patients. There were 7 malignancies, of which 5 had been suspected clinically and one had been diagnosed as gynaecomastia by mammography. Two carcinomas in situ were missed clinically and also by mammography. When malignancy is not suspected on clinical grounds the first examination should be sonography. Where, however, malignancy is suspected, and for follow-up, mammography retains its primary position. (orig./MG) [Deutsch] In einem 4-Jahres-Zeitraum wurden bei 89 Maennern insgesamt 104 Mammogramme angefertigt. 23 Maenner (=Gruppe 1) wurden mastektomiert. 66 Patienten (=Gruppe 2) wurden klinisch und zum Teil mammographisch kontrolliert. Alle Mammogramme wurden in Unkenntnis des klinischen Befundes retrospektiv ausgewertet und, wenn moeglich, dem histologischen Ergebnis gegenuebergestellt. In der Gruppe 1 fand sich eine beidseitige Gynaekomastie in 5/23 Faellen, eine einseitige Form in 9/23 Faellen, eine Pseudogynaekomastie in 2/23 Faellen und ein Malignom in 7/23 Faellen. In Gruppe 2 ergab sich eine beidseitige Gynaekomastie in 46/81 Faellen gegenueber einer einseitigen Form in 10/81 Faellen. Eine Pseudogynaekomastie fand sich in 25/81 Faellen. Von 7 Malignomen waren 5 klinisch suspekt, wobei eines mammographisch als Gynaekomastie imponierte. Zwei In-situ-Karzinome waren sowohl mammographisch als auch klinisch okkult. Klinisch nicht malignomsuspekte Befunde sollten primaer der Mammasonographie zugefuehrt werden. Bei

  8. Breast Cancer Detection: Mammography and other methods in breast imaging, second edition

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.

    1987-01-01

    The text addresses mammography and the advantages and limitations of other breast imaging methods presently available. The establishment of X-ray mammography as the safest and most accurate noninvasive method of early, nonpalpable breast cancer detection is addressed in the first section of the book. The second section emphasizes the signs of early cancer, the complete mammographic examination, and the team approach to diagnosis. The advantages and limitations of film-screen mammography, zero mammography, breast ultrasound, thermography, light scanning, magnetic resonance imaging, and ductography are highlighted as alternate methods of detection. The benefits of mammography, and its unmatched value in screeening for breast cancer, are presented in the final section

  9. Response costs of mammography adherence: Iranian women's perceptions.

    Science.gov (United States)

    Khodayarian, Mahsa; Mazloomi-Mahmoodabad, Seyed Saied; Lamyian, Minoor; Morowatisharifabad, Mohammad Ali; Tavangar, Hossein

    2016-01-01

    Mammography as the most common secondary prevention method has known to be helpful in detecting breast cancer at the early stages. Low level of participation among women toward mammography uptake due to cultural beliefs is a great concern. This study aimed at exploring the perceptions of women about response costs of mammography adherence (MA) in Yazd, Iran. A qualitative study using semi-structured interviews was performed. Fourteen women,one oncology nurse, and a breast cancer survivor were purposefully interviewed. Interviews were transcribed verbatim and analyzed by directed content analysis method based on protection motivation theory (PMT). One main theme was emerged from the analysis namely called "response costs".Two main categories were also emerged from the data; (1) psychological barriers with six subcategories including "embarrassment," "worry about being diagnosed with cancer," "preoccupation with underlying disease," "misconception about mammography," "need for an accompanying person," and "internalizing the experiences of the others," and (2) maladaptive coping modes which encompassed three subcategories: "religious faith," "fatalism," and"avoidance and denial." Useful information was provided about the response costs of mammography utilization based on the perceptions of women. Cognitive barriers may be decreased by conducting modifications in women's awareness and attitude toward MA as well as changing the national health system infrastructures. Incorporating religious and cultural belief systems into MA educational programs through motivational messages is recommended.

  10. Study of mammography in mass screening for breast cancer

    International Nuclear Information System (INIS)

    Kitada, Masahiro; Sakai, Hiroko; Kubo, Yoshihiko; Samejima, Natsuki; Kurowarabi, Kunio; Iwabuchi, Shuji.

    1995-01-01

    In order to examine the rate of correct diagnosis by mammography at initial mass screening for breast cancer, we carried out a retrospective study of mammography findings in 267 cases of breast cancer detected at Asahikawa Cancer Screening Center. The screening was performed by physical examination, and in cases where disease was suspected, mammography, ultrasonography, and needle biopsy were done. Mammographically, 172 cases (64.4%) were cancer-positive, 58 cases (21.7%) were suspicious for cancer, and 37 cases (13.9%) were cancer-negative. Patients below 50 years of age and those with tumors of small diameter (<20 mm) showed a significantly lower rate of cancer positivity than patients aged 50 years or more and those with tumors 20 mm or more in diameter. Mammographic abnormalities were not specific, since these changes were also found in normal subjects and patients with benign diseases. Therefore, we concluded that mammography without physical examination at initial mass screening has a high risk of missing breast cancer. Mass screening for breast cancer should be performed by physical examination involving inspection and palpation at the first instance. If any suspicious findings are obtained, mammography, ultrasonography, and needle biopsy should be done. (author)

  11. Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.

    Science.gov (United States)

    Dang, Pragya A; Freer, Phoebe E; Humphrey, Kathryn L; Halpern, Elkan F; Rafferty, Elizabeth A

    2014-01-01

    To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. In this HIPAA-compliant, institutional review board-approved study, 10 radiologists prospectively read images from screening digital mammography or screening combined tomosynthesis and mammography examinations for 1-hour-long uninterrupted sessions. Images from 3665 examinations (1502 combined and 2163 digital mammography) from July 2012 to January 2013 were interpreted in at least five sessions per radiologist per modality. The number of cases reported during each session was recorded for each reader. The experience level for each radiologist was also correlated to the average number of cases reported per hour. Analysis of variance was used to assess the number of studies interpreted per hour. A linear regression model was used to evaluate correlation between breast imaging experience and time taken to interpret images from both modalities. The mean number of studies interpreted in hour was 23.8 ± 0.55 (standard deviation) (range, 14.4-40.4) for combined tomosynthesis and mammography and 34.0 ± 0.55 (range, 20.4-54.3) for digital mammography alone. A mean of 10.2 fewer studies were interpreted per hour during combined tomosynthesis and mammography compared with digital mammography sessions (P tomosynthesis and mammography and 1.9 minutes ± 0.6 (range, 1.1-3.0) for digital mammography; interpretation time with combined tomosynthesis and mammography was 0.9 minute longer (47% longer) compared with digital mammography alone (P tomosynthesis and mammography examinations decreased (R(2) = 0.52, P = .03). Addition of tomosynthesis to mammography results in increased time to interpret images from screening examinations compared

  12. Screen-film mammography versus full-field digital mammography in a population-based screening program: The Sogn and Fjordane study

    International Nuclear Information System (INIS)

    Juel, Inger-Marie; Johannessen, Gunnar; Skaane, Per; Roth Hoff, Solveig; Hofvind, Solveig

    2010-01-01

    Background: Studies comparing analog and digital mammography in breast cancer screening have shown conflicting results. Little is known about the use of digital photon-counting detectors. Purpose: To retrospectively compare performance indicators in screen-film (SFM) and full-field digital mammography (FFDM) using a photon-counting detector in a population-based screening program. Material and Methods: The Norwegian Social Science Data Services approved the study, which was part of the Norwegian Breast Cancer Screening Program. The program invites women aged 50-69 years to two-view mammography biannually. The study period was January 2005 to June 2006 for SFM and August 2006 to December 2007 for FFDM. Independent double reading was performed using a five-point rating scale for probability of cancer. Recalls due to abnormal mammography were retrospectively reviewed by an expert panel. Performance indicators for the two techniques were compared. Attendance rate was 83.6% (7442/8901) for SFM and 82.0% (6932/8451) for FFDM. Results: The recall rate due to abnormal mammography, cancer detection rate and positive predictive value did not differ significantly between SFM and FFDM: recall 2.3% (174/7442) versus 2.4% (168/6932), cancer detection 0.39% (29/7442) versus 0.48% (33/6932), positive predictive value 16.7% (29/174) versus 19.6% (33/168), respectively (P>0.05 for all). The recall rate due to technically inadequate mammograms was 0.3% (19/7442) for SFM and 0.01% (1/6932) for FFDM. In the retrospective review, a significantly higher proportion of calcifications and asymmetric density were categorized as normal or definitively benign in FFDM compared with SFM. The average glandular dose was 2.17 mGy for SFM and 1.25 mGy for FFDM. Conclusion: Performance indicators show that FFDM using photon-counting detector is suitable for breast cancer screening. The lower radiation dose and lower recalls due to technically inadequate mammograms are of importance in mammography

  13. A case report of ureteral cast stone and giant urethral stone, respectively

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Yung; Rhee, Song Joo; Choi, Ki Chul [School of Medicine, Jeongbug National University, Jeonju (Korea, Republic of)

    1980-12-15

    Urinary lithiasis is one of the most common disease of the urinary tract. It occurs more frequently in men than in women but rare in children and in blacks; a familial predisposition is often encountered. Ureteral stones originate in the kidney. Gravity and peristalis contribute to spontaneous passage into and down the ureter. Ureterovesical junction is the most frequent lodging site of stone. In our hospital one case of ureteral cast stone and giant urethral stone were found respectively and they were confirmed by radiological examination and surgery on Aug. 1978 and Jan. 1979. Ureteral cast stone which had been introduced and named first by Kiyonobu Tari and Kikjiro So in 1972 was very giant unusually. It may be the only one till now. Our patient was 36 years old female who has been suffered from intermittent right flank pain for 10 years. On KUB giant cylindrical radiopaque shadow was shown on RLQ extended to right minor pelvis and this was confirmed as a stone by retrograde ureteral catheterization. A stone measured 13cm x 1.5cm was found above the ureterovesical junction during operation. Follow up excretory urogram one year after operation showed no functional improvement of right kidney. Urethral stone is also unusual urinary lithiasis. This 60 years old male patient was been suffered from non-tender palpable hard mass on scrotal area and intermittent urinary retention. When urinary retention was occurred it was relieved by manipulation of the mass by himself. On plain film oval shaped giant radiopaque shadow was shown on cavernous urethral region. On urethrocystogram anterior urethra was opacified, but posterior urethra and bladder were not opacified and multiple fistulous leakage was identified. A stone measured 6.5cm x 3.5cm was found in cavernous urethra during operation.

  14. A case report of ureteral cast stone and giant urethral stone, respectively

    International Nuclear Information System (INIS)

    Song, Ho Yung; Rhee, Song Joo; Choi, Ki Chul

    1980-01-01

    Urinary lithiasis is one of the most common disease of the urinary tract. It occurs more frequently in men than in women but rare in children and in blacks; a familial predisposition is often encountered. Ureteral stones originate in the kidney. Gravity and peristalis contribute to spontaneous passage into and down the ureter. Ureterovesical junction is the most frequent lodging site of stone. In our hospital one case of ureteral cast stone and giant urethral stone were found respectively and they were confirmed by radiological examination and surgery on Aug. 1978 and Jan. 1979. Ureteral cast stone which had been introduced and named first by Kiyonobu Tari and Kikjiro So in 1972 was very giant unusually. It may be the only one till now. Our patient was 36 years old female who has been suffered from intermittent right flank pain for 10 years. On KUB giant cylindrical radiopaque shadow was shown on RLQ extended to right minor pelvis and this was confirmed as a stone by retrograde ureteral catheterization. A stone measured 13cm x 1.5cm was found above the ureterovesical junction during operation. Follow up excretory urogram one year after operation showed no functional improvement of right kidney. Urethral stone is also unusual urinary lithiasis. This 60 years old male patient was been suffered from non-tender palpable hard mass on scrotal area and intermittent urinary retention. When urinary retention was occurred it was relieved by manipulation of the mass by himself. On plain film oval shaped giant radiopaque shadow was shown on cavernous urethral region. On urethrocystogram anterior urethra was opacified, but posterior urethra and bladder were not opacified and multiple fistulous leakage was identified. A stone measured 6.5cm x 3.5cm was found in cavernous urethra during operation

  15. Extracorporeal shock wave lithotripsy of intrahepatic stones with piezoelectric lithotriptor: in vitro study

    International Nuclear Information System (INIS)

    Choi, Byung Ihn; Yoon, Chong Hyun; Park, Yong Hyun; Han, Joon Koo; Yoon, Yong Bum; Shin, Yong Moon; Kim, Jin Q; Kim, Chu Wan; Han, Man Chung

    1992-01-01

    This study was designed to investigate effectiveness of fragmentation during lithotripsy using 103 intrahepatic stones collected from 10 patients, who had previously undergone biliary surgery. The size of each stone was measured and sonography was performed for the evaluation of the sonographic type of the stones. In vitro lithotripsy was performed on individual stones using piezoelectric lithotriptor to evaluate the fragmentation rate and average number of shock waves for fragmentation. Chemical analysis of each stone was done to determine chemical composition including calcium, bilirubin, and cholesterol. The size of the stones was from 5 mm to 20 mm in diameter. Sonographic type I (echo of whole stone with posterior acoustic shadow) was 68, and type II (are-like strong surface echo of stone with clear posterior acoustic shadow) was 35 in number. The majority (78%) of stones in group I (5-9 mm in diameter) showed sonographic type I characteristics, and 62% of stones in group 3 (larger than 15 mm in diameter) showed sonographic type II characteristics. There was a positive correlation between the size and sonographic type of stones. Fragmentation rates of stones were 100% in group I, 71.9% in group 2 (10-15 mm in diameter), 43.8% in group 3, respectively. Fragmentation rates of stones with sonographic type I and II were 91.2%, 65.7%, respectively. The average number of shock waves for partial and complete fragmentation was 2753 ± 4937 and 6219 ± 10133, respectively. There was a positive correlation between the number of shock waves for fragmentation and diameter of stones (r = 0.618, ρ < 0.05). There was no correlation between the number of shock waves for fragmentation and chemical composition of stones. In conclusion, the most important variable determining the degree of fragmentation of intrahepatic stones using ESWL is not their chemical composition but their size and sonographic characteristics

  16. Extracorporeal shock wave lithotripsy of intrahepatic stones with piezoelectric lithotriptor: in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Byung Ihn; Yoon, Chong Hyun; Park, Yong Hyun; Han, Joon Koo; Yoon, Yong Bum; Shin, Yong Moon; Kim, Jin Q; Kim, Chu Wan; Han, Man Chung [Seoul National University, College of Medicine, Seoul (Korea, Republic of)

    1992-05-15

    This study was designed to investigate effectiveness of fragmentation during lithotripsy using 103 intrahepatic stones collected from 10 patients, who had previously undergone biliary surgery. The size of each stone was measured and sonography was performed for the evaluation of the sonographic type of the stones. In vitro lithotripsy was performed on individual stones using piezoelectric lithotriptor to evaluate the fragmentation rate and average number of shock waves for fragmentation. Chemical analysis of each stone was done to determine chemical composition including calcium, bilirubin, and cholesterol. The size of the stones was from 5 mm to 20 mm in diameter. Sonographic type I (echo of whole stone with posterior acoustic shadow) was 68, and type II (are-like strong surface echo of stone with clear posterior acoustic shadow) was 35 in number. The majority (78%) of stones in group I (5-9 mm in diameter) showed sonographic type I characteristics, and 62% of stones in group 3 (larger than 15 mm in diameter) showed sonographic type II characteristics. There was a positive correlation between the size and sonographic type of stones. Fragmentation rates of stones were 100% in group I, 71.9% in group 2 (10-15 mm in diameter), 43.8% in group 3, respectively. Fragmentation rates of stones with sonographic type I and II were 91.2%, 65.7%, respectively. The average number of shock waves for partial and complete fragmentation was 2753 {+-} 4937 and 6219 {+-} 10133, respectively. There was a positive correlation between the number of shock waves for fragmentation and diameter of stones (r = 0.618, {rho} < 0.05). There was no correlation between the number of shock waves for fragmentation and chemical composition of stones. In conclusion, the most important variable determining the degree of fragmentation of intrahepatic stones using ESWL is not their chemical composition but their size and sonographic characteristics.

  17. Differential Effects of Social Networks on Mammography Use by Poverty Status.

    Science.gov (United States)

    Yeo, Younsook

    2016-01-01

    This study examines whether social networks have differential effects on mammography use depending on poverty status. Data were analyzed on US women (40+), employing logistic regression and simple slope analyses for a post hoc probing of moderating effects. Among women not in poverty, living with a spouse/partner and attending church, regardless of frequency, were positively associated with mammography use; family size was negatively associated. Among women living in poverty, mammography showed a positive association only with weekly church attendance. Mammography was negatively associated with health-related social interactions occurring through the Internet. Post hoc probing showed significant moderating effects of poverty on the relationship between online health-related interactions and mammography use. To make the Internet a meaningful health empowerment tool for women in poverty, future research should identify how health-related interactions that occur online affect women in poverty's psychological and behavioral reactions that will contribute to our understanding of why they are discouraged from having mammograms. The mechanisms behind the differential effects of church attendance and poverty status on mammography also need further clarification.

  18. Stone tools from locality Crkvine in Stubline

    Directory of Open Access Journals (Sweden)

    Antonović Dragana

    2011-01-01

    small dimensions and numerous natural fractures. We suppose that the pebbles present waste material and that the Pottery group 1 represented a dump place next to the house. It is possible that this stone material was crushed and added in clay used for making pottery vassels. This conclusion is done on the basis of two facts: within the Pottery group 1there were found numerous ceramic fragments that could not be used for reconstruction of any vessel, and ceramics from the locality Crkvine was baked from soil with lot of fine grained quartzite. Taking into consideration that only the small part of the setlement (practically one hose was excavated in 2008, it is still too early to make general conclusions about the mentioned distribution of the stone findings. Moreover, in this part of the locality, the Vinča layers are disturbed by a necropole from 17-18. centuries, and maybe that could made increasing of stone findings distribution abouve and around the graves, in southern part of the House 1/2008. Obsereved as whole, with all defined basic types of chipped artifacts, this collection does not provide observation of possible local characteristics which could specifically and obviously indicate big diferences between material of the Late Vinča and older neolithic period. Number of samples is too small with prevailed unretouched flakes and blades which represent more than a half of the findings, while the retouched samples show an average degree of production quality. The artifacts do not exhibit unusual and for previous periods unknown technological procedures in making tools. The retouched artifacts fit to the already defined typological frame which, at the end of the Neolithic, unequivocally announce gradual degradation and slow extinction of the technology which has labelled the largest period of prehistory and established the fundament of civilization. The largest significance of this small collection is obvious in the presence of white and grayish-green chert

  19. The influence of heavy mineral crushing in analysis of U mobile

    International Nuclear Information System (INIS)

    Tatang-Suherman

    2000-01-01

    The aim of experiments is to find out the influence of sample crushing in analysis of U mobile it was compared between U content of crusher and uncrushed samples. The uncrushed samples including the grain size of minus 40, 60, 80 and 100 mesh, since while the uncrushed sample was minus 60, 80, 100, 120 and 150 mesh. The U analysis was done by comparing with fluorescence of standard sample using Fluorimetric determination. The result of uncrushed samples have a same concentration in all of grain fractions and the crushed samples have a higher concentration on the smallest of grain fractions. The content of U mobile from crushed sample have significant result at - 120 mesh to - 150 mesh

  20. Modeling elastic wave propagation in kidney stones with application to shock wave lithotripsy.

    Science.gov (United States)

    Cleveland, Robin O; Sapozhnikov, Oleg A

    2005-10-01

    A time-domain finite-difference solution to the equations of linear elasticity was used to model the propagation of lithotripsy waves in kidney stones. The model was used to determine the loading on the stone (principal stresses and strains and maximum shear stresses and strains) due to the impact of lithotripsy shock waves. The simulations show that the peak loading induced in kidney stones is generated by constructive interference from shear waves launched from the outer edge of the stone with other waves in the stone. Notably the shear wave induced loads were significantly larger than the loads generated by the classic Hopkinson or spall effect. For simulations where the diameter of the focal spot of the lithotripter was smaller than that of the stone the loading decreased by more than 50%. The constructive interference was also sensitive to shock rise time and it was found that the peak tensile stress reduced by 30% as rise time increased from 25 to 150 ns. These results demonstrate that shear waves likely play a critical role in stone comminution and that lithotripters with large focal widths and short rise times should be effective at generating high stresses inside kidney stones.

  1. Soft copy digital mammography

    International Nuclear Information System (INIS)

    Kim, Hak Hee

    2005-01-01

    Screen-film mammography (SFM) has been the standard method used for breast cancer screening and making a clinical diagnosis. It is a valuable modality for the detection and differentiation of breast calcifications. The advantages are the high spatital resolution, the convenient display, and inexpensiveness. However, it has some inherent limitations such as its low detective quantum efficiency and difficulty of post-processing after obtaining after an image. Digital mammography (DM) has the potential to overcome the inherent limitations of SFM. DM systems directly qualify x-ray photons and decouple the process of x-ray photon detection from the image display. The digital images can be processed by a computer and displayed in multiple formats. Thus, DM is better than SFM for the detection of mass lesions due to its high contrast resolution

  2. Rock Crushing Using Microwave Pre-Treatment

    KAUST Repository

    Kim, Seunghee; Santamarina, Carlos

    2016-01-01

    Crushing and grinding are primary contributors to a high energy demand in the mining industry, yet, both are surprisingly inefficient processes, often with efficiencies as low as 1%. We analyze size reductions during crushing and grinding operations and explore the potential of multiplying internal weaknesses in rock materials by non-mechanical means. In particular, when rock blocks (wet or even dry if polycrystalline) are exposed to microwaves, internal cracks can develop along grain boundaries via differential thermal expansion between grains and volumetric thermal expansion of water in pores. Brazilian tests conducted on granite and cement mortar specimens show that the tensile strength decreases proportional to the duration of microwave treatment. Thermal changes, excessive fluid pressure buildup and induced stresses are analyzed in the context of hydro-Thermo-mechanically coupled processes. Results confirm that both differential thermal expansion of mineral grains and volumetric thermal expansion of water can generate cracks upon microwave exposure. Optimal conditions are suggested to lower the combined consumption of electric and mechanical energy.

  3. Rock Crushing Using Microwave Pre-Treatment

    KAUST Repository

    Kim, Seunghee

    2016-08-11

    Crushing and grinding are primary contributors to a high energy demand in the mining industry, yet, both are surprisingly inefficient processes, often with efficiencies as low as 1%. We analyze size reductions during crushing and grinding operations and explore the potential of multiplying internal weaknesses in rock materials by non-mechanical means. In particular, when rock blocks (wet or even dry if polycrystalline) are exposed to microwaves, internal cracks can develop along grain boundaries via differential thermal expansion between grains and volumetric thermal expansion of water in pores. Brazilian tests conducted on granite and cement mortar specimens show that the tensile strength decreases proportional to the duration of microwave treatment. Thermal changes, excessive fluid pressure buildup and induced stresses are analyzed in the context of hydro-Thermo-mechanically coupled processes. Results confirm that both differential thermal expansion of mineral grains and volumetric thermal expansion of water can generate cracks upon microwave exposure. Optimal conditions are suggested to lower the combined consumption of electric and mechanical energy.

  4. At what age should screening mammography be recommended for Asian women?

    International Nuclear Information System (INIS)

    Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi

    2015-01-01

    Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40–49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan

  5. Introduction. Leave no stone unturned: Perspectives on ground stone artefact research

    OpenAIRE

    Danny Rosenberg; Yorke Rowan; Tatjana Gluhak

    2016-01-01

    Ground stone tools served in many physical and social contexts through millennia, reflecting a wide variety of functions. Although ground stone tool studies were neglected for much of early archaeology, the last few decades witnessed a notable international uptick in the way archaeologists confront this multifaceted topic. Today, with the advance of archaeology as a discipline, research into ground stone artefacts is moving into a new phase that integrates high resolution documentation with n...

  6. Treatment of gallbladder stone with common bile duct stones in the laparoscopic era.

    Science.gov (United States)

    Zhang, Wei-jie; Xu, Gui-fang; Huang, Qin; Luo, Kun-lun; Dong, Zhi-tao; Li, Jie-ming; Wu, Guo-zhong; Guan, Wen-xian

    2015-01-26

    Laparoscopic common bile duct exploration (LCBDE) for stone can be carried out by either laparoscopic transcystic stone extraction (LTSE) or laparoscopic choledochotomy (LC). It remains unknown as to which approach is optimal for management of gallbladder stone with common bile duct stones (CBDS) in Chinese patients. From May 2000 to February 2009, we prospective treated 346 consecutive patients with gallbladder stones and CBDS with laparoscopic cholecystectomy and LCBDE. Intraoperative findings, postoperative complications, postoperative hospital stay and costs were analyzed. Because of LCBDE failure,16 cases (4.6%) required open surgery. Of 330 successful LCBDE-treated patients, 237 underwent LTSE and 93 required LC. No mortality occurred in either group. The bile duct stone clearance rate was similar in both groups. Patients in the LTSE group were significantly younger and had fewer complications with smaller, fewer stones, shorter operative time and postoperative hospital stays, and lower costs, compared to those in the LC group. Compared with patients with T-tube insertion, patients in the LC group with primary closure had shorter operative time, shorter postoperative hospital stay, and lower costs. In cases requiring LCBDE, LTSE should be the first choice, whereas LC may be restricted to large, multiple stones. LC with primary closure without external drainage of the CBDS is as effective and safe as the T-tube insertion approach.

  7. CRUSH1: a simplified computer program for impact analysis of radioactive material transport casks

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, Takeshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-07-01

    In drop impact analyses for radioactive transport casks, it has become possible to perform them in detail by using interaction evaluation, computer programs, such as DYNA2D, DYNA3D, PISCES and HONDO. However, the considerable cost and computer time are necessitated to perform analyses by these programs. To meet the above requirements, a simplified computer program CRUSH1 has been developed. The CRUSH1 is a static calculation computer program capable of evaluating the maximum acceleration of cask bodies and the maximum deformation of shock absorbers using an Uniaxial Displacement Method (UDM). The CRUSH1 is a revised version of the CRUSH. Main revisions of the computer program are as follows; (1) not only main frame computer but also work stations (OS UNIX) and personal computer (OS Windows 3.1 or Windows NT) are available for use of the CRUSH1 and (2) input data set are revised. In the paper, brief illustration of calculation method using UDM is presented. The second section presents comparisons between UDM and the detailed method. The third section provides a use`s guide for CRUSH1. (author)

  8. CRUSH1: a simplified computer program for impact analysis of radioactive material transport casks

    International Nuclear Information System (INIS)

    Ikushima, Takeshi

    1996-07-01

    In drop impact analyses for radioactive transport casks, it has become possible to perform them in detail by using interaction evaluation, computer programs, such as DYNA2D, DYNA3D, PISCES and HONDO. However, the considerable cost and computer time are necessitated to perform analyses by these programs. To meet the above requirements, a simplified computer program CRUSH1 has been developed. The CRUSH1 is a static calculation computer program capable of evaluating the maximum acceleration of cask bodies and the maximum deformation of shock absorbers using an Uniaxial Displacement Method (UDM). The CRUSH1 is a revised version of the CRUSH. Main revisions of the computer program are as follows; (1) not only main frame computer but also work stations (OS UNIX) and personal computer (OS Windows 3.1 or Windows NT) are available for use of the CRUSH1 and (2) input data set are revised. In the paper, brief illustration of calculation method using UDM is presented. The second section presents comparisons between UDM and the detailed method. The third section provides a use's guide for CRUSH1. (author)

  9. European radiographers' challenges from mammography education and clinical practice - an integrative review.

    Science.gov (United States)

    Metsälä, Eija; Richli Meystre, Nicole; Pires Jorge, José; Henner, Anja; Kukkes, Tiina; Sá Dos Reis, Cláudia

    2017-06-01

    This study aims to identify European radiographers' challenges in clinical performance in mammography and the main areas of mammography that require more and better training. An extensive search was performed to identify relevant studies focused on clinical practice, education and training in mammography published between January 2010 and December 2015 in the English language. The data were analysed by using deductive thematic analysis. A total of 27 full text articles were read, evaluating their quality. Sixteen articles out of 27 were finally selected for this integrative review. The main challenges of radiographers' mammography education/training can be divided into three groups: training needs, challenges related to radiographers, and challenges related to the organization of education. The most common challenges of clinical performance in mammography among European radiographers involved technical performance, the quality of practices, and patient-centeredness. The introduction of harmonized mammography guidelines across Europe may serve as an evidence-based tool to be implemented in practice and education. However, the variability in human and material resources as well as the different cultural contexts should be considered during this process. • Radiographers' awareness of their professional identity and enhancing multiprofessional cooperation in mammography. • Radiographers' responsibilities regarding image quality (IQ) and optimal breast imaging performance. • Patient-centred mammography services focusing on the psychosocial needs of the patient. • Challenges: positioning, QC-testing, IQ-assessment, optimization of breast compression, communication, teamwork, and patient-centred care. • Introduction of evidence-based guidelines in Europe to harmonize mammography practice and education.

  10. Effect of Raw Crushed Garlic (Allium sativum L.) on Components of Metabolic Syndrome.

    Science.gov (United States)

    Choudhary, Prema Ram; Jani, Rameshchandra D; Sharma, Megh Shyam

    2017-09-28

    Metabolic syndrome consists of a group of risk factors characterized by abdominal obesity, hypertension, atherogenic dyslipidemia, hyperglycemia, and prothrombotic and proinflammatory conditions. Raw garlic homogenate has been reported to reduce serum lipid levels in animal model; however, no precise studies have been performed to evaluate the effect of raw crushed garlic (Allium sativum L.) on components of metabolic syndrome. Therefore, the present study was designed to investigate the effect of raw crushed garlic on components of metabolic syndrome. A total of 40 metabolic syndrome patients were randomly selected from the diabetic center of SP Medical College, Bikaner, Rajasthan, India. They underwent treatment with 100 mg/kg body weight raw crushed garlic 2 times a day with standard diet for 4 weeks; their anthropometric and serum biochemical variables were measured at both the beginning and the end of the study. Statistical analysis was performed using IBM SPSS version 20, and Student's paired "t" test was used to compare variables before and after treatment with garlic preparation. Raw crushed garlic significantly reduced components of metabolic syndrome including waist circumference (p .05) of patients with metabolic syndrome after consumption of raw crushed garlic for 4 weeks. Raw crushed garlic has beneficial effects on components of metabolic syndrome; therefore, it can be used as an accompanying remedy for prevention and treatment of patients with metabolic syndrome.

  11. Everybody Must Get Stones

    Directory of Open Access Journals (Sweden)

    Timothy Darvill

    2009-09-01

    Full Text Available It is now widely recognised that monument building in the fourth and third millennia cal BC often involved transporting selected blocks of preferred stone many kilometres over difficult terrain. Some structures incorporated blocks from several different sources, brought together as an ensemble in much the same way perhaps that assemblages of flint and stone axes reflect both local and distant sources. This article explores alternative models accounting for the selection of stones, contrasting those that foreground symbolic attachments and imposed meanings with those that focus on the intrinsic qualities of particular types of stone and their source. The assemblage of different stone types that accumulated at Stonehenge, Wiltshire, over a period of more than a thousand years is used as a case study.

  12. Mammography Screening Trends: The Perspective of African American Women Born Pre/Post World War II

    Science.gov (United States)

    Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A.

    2013-01-01

    Researchers have traditionally combined aging women (aged ≥50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non–baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non–baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947–0.968) cohort effects may have partially reversed the age effect, with non–baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278–2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population. PMID:20575209

  13. Luminescence dating of anthropogenic features of the San Luis Valley, Colorado: from stone huts to stone walls

    Science.gov (United States)

    Mahan, Shannon; Donlan, Rebecca A.; Kardos, Barbara Maat

    2015-01-01

    The Snake Nest Wall site and the Crestone Stone Huts are in the northern San Luis Valley, Colorado, and provide a unique opportunity to date high-altitude archeological sites of unknown age and origin using optically stimulated luminescence (OSL). We sampled sediment underlying foundation stones of these structures to establish a chronological framework for each site's construction. OSL dating of the quartz grains directly under the Snake Nest Wall suggest that the stones and, therefore, the structure was most recently emplaced between 1855 and 1890 A.D. Dating of the sediment beneath the Crestone Stone Huts suggests the construction time of these huts is between 1860 and 1890 A.D. Analysis of the equivalent dose (DE) dispersion of the OSL samples at Snake Nest Wall and the Crestone Huts shows that the majority of sediments were fully bleached prior to deposition and the low scatter suggests that short-term or shallow alluvial processes were the dominant transport for sediments. In both cases, the OSL ages show that the construction was during very recent historical times, although it is likely that the Snake Nest Wall was rebuilt in the late 19th century. Further study is warranted at the Snake Nest Wall since it shows signs of greater antiquity and a continued presence of human use. The Crestone Huts are shown to be a product of railroad building during the boomtown days of Lucky and Crestone.

  14. Decision making and counseling around mammography screening for women aged 80 or older.

    Science.gov (United States)

    Schonberg, Mara A; Ramanan, Radhika A; McCarthy, Ellen P; Marcantonio, Edward R

    2006-09-01

    Despite uncertain benefit, many women over age 80 (oldest-old) receive screening mammography. To explore decision-making and physician counseling of oldest-old women around mammography screening. Qualitative research using in-depth semi-structured interviews. Twenty-three women aged 80 or older who received care at a large academic primary care practice (13 had undergone mammography screening in the past 2 years) and 16 physicians at the same center. We asked patients and physicians to describe factors influencing mammography screening decisions of oldest-old women. We asked physicians to describe their counseling about screening to the oldest-old. Patients and/or physicians identified the importance of physician influence, patient preferences, system factors, and social influences on screening decisions. Although physicians felt that patient's health affected screening decisions, few patients felt that health mattered. Three types of elderly patients were identified: (1) women enthusiastic about screening mammography; (2) women opposed to screening mammography; and (3) women without a preference who followed their physician's recommendation. However, physician counseling about mammography screening to elderly women varies; some individualize discussions; others encourage screening; few discourage screening. Physicians report that discussions about stopping screening can be uncomfortable and time consuming. Physicians suggest that more data could facilitate these discussions. Some oldest-old women have strong opinions about screening mammography while others are influenced by physicians. Discussions about stopping screening are challenging for physicians. More data about the benefits and risks of mammography screening for women aged 80 or older could inform patients and improve provider counseling to lead to more rational use of mammography.

  15. Psychosocial predictors of first attendance for organised mammography screening

    DEFF Research Database (Denmark)

    Aro, A R; de Koning, H J; Absetz, P

    1999-01-01

    Scale, Illness Attitude Scale, Health Locus of Control Scale, Anxiety Inventory, and Depression Inventory. Univariate and multivariate logistic regression analyses were used to predict attendance. RESULTS: Those most likely to attend were working, middle income, and averagely educated women, who had...... not had a mass mammogram recently, but who regularly visited gynaecologists, attended for Pap smear screening, practised breast self examination, and who did not smoke. Low confidence in their own capabilities in breast cancer prevention, overoptimism about the sensitivity of mammography, and perception...

  16. Can positron emission mammography help to identify clinically significant breast cancer in women with suspicious calcifications on mammography?

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir G.V.; Lima, Eduardo N.P.; Macedo, Bruna R.C.; Conrado, Jorge L.F.A.; Marques, Elvira F.; Chojniak, Rubens [A C Camargo Cancer Center-Department of Imaging, Sao Paulo, SP (Brazil)

    2017-05-15

    To evaluate the diagnostic accuracy of positron emission mammography (PEM) for identifying malignant lesions in patients with suspicious microcalcifications detected on mammography. A prospective, single-centre study that evaluated 40 patients with suspicious calcifications at mammography and indication for percutaneous or surgical biopsy, with mean age of 56.4 years (range: 28-81 years). Patients who agreed to participate in the study underwent PEM with 18F-fluorodeoxyglucose before the final histological evaluation. PEM findings were compared with mammography and histological findings. Most calcifications (n = 34; 85.0 %) were classified as BIRADS 4. On histology, there were 25 (62.5 %) benign and 15 (37.5 %) malignant lesions, including 11 (27.5 %) ductal carcinoma in situ (DCIS) and 4 (10 %) invasive carcinomas. On subjective analysis, PEM was positive in 15 cases (37.5 %) and most of these cases (n = 14; 93.3 %) were confirmed as malignant on histology. There was one false-positive result, which corresponded to a fibroadenoma, and one false negative, which corresponded to an intermediate-grade DCIS. PEM had a sensitivity of 93.3 %, specificity of 96.0 % and accuracy of 95 %. PEM was able to identify all invasive carcinomas and high-grade DCIS (nuclear grade 3) in the presented sample, suggesting that this method may be useful for further evaluation of patients with suspected microcalcifications. (orig.)

  17. Ultrasonic propulsion of kidney stones.

    Science.gov (United States)

    May, Philip C; Bailey, Michael R; Harper, Jonathan D

    2016-05-01

    Ultrasonic propulsion is a novel technique that uses short bursts of focused ultrasonic pulses to reposition stones transcutaneously within the renal collecting system and ureter. The purpose of this review is to discuss the initial testing of effectiveness and safety, directions for refinement of technique and technology, and opinions on clinical application. Preclinical studies with a range of probes, interfaces, and outputs have demonstrated feasibility and consistent safety of ultrasonic propulsion with room for increased outputs and refinement toward specific applications. Ultrasonic propulsion was used painlessly and without adverse events to reposition stones in 14 of 15 human study participants without restrictions on patient size, stone size, or stone location. The initial feasibility study showed applicability in a range of clinically relevant situations, including facilitating passage of residual fragments following ureteroscopy or shock wave lithotripsy, moving a large stone at the ureteropelvic junction with relief of pain, and differentiating large stones from a collection of small fragments. Ultrasonic propulsion shows promise as an office-based system for transcutaneously repositioning kidney stones. Potential applications include facilitating expulsion of residual fragments following ureteroscopy or shock wave lithotripsy, repositioning stones prior to treatment, and repositioning obstructing ureteropelvic junction stones into the kidney to alleviate acute renal colic.

  18. Strain-rate effect on initial crush stress of irregular honeycomb under dynamic loading and its deformation mechanism

    Science.gov (United States)

    Wang, Peng; Zheng, Zhijun; Liao, Shenfei; Yu, Jilin

    2018-02-01

    The seemingly contradictory understandings of the initial crush stress of cellular materials under dynamic loadings exist in the literature, and a comprehensive analysis of this issue is carried out with using direct information of local stress and strain. Local stress/strain calculation methods are applied to determine the initial crush stresses and the strain rates at initial crush from a cell-based finite element model of irregular honeycomb under dynamic loadings. The initial crush stress under constant-velocity compression is identical to the quasi-static one, but less than the one under direct impact, i.e. the initial crush stresses under different dynamic loadings could be very different even though there is no strain-rate effect of matrix material. A power-law relation between the initial crush stress and the strain rate is explored to describe the strain-rate effect on the initial crush stress of irregular honeycomb when the local strain rate exceeds a critical value, below which there is no strain-rate effect of irregular honeycomb. Deformation mechanisms of the initial crush behavior under dynamic loadings are also explored. The deformation modes of the initial crush region in the front of plastic compaction wave are different under different dynamic loadings.

  19. THE VALUE OF ULTRASOUND MAMMOGRAPHY IN PALPABLE BREAST MASSES

    NARCIS (Netherlands)

    VANOORD, JC; VANDERVLIET, AM; THYN, CJP; MAK, B; HOOGEBOOM, GJ

    Between January 1987 and May 1988 a prospective study was carried out on 232 women with a palpable breast mass. They underwent physical examination, x-ray mammography and ultrasound mammography. The results of each study were interpreted independently by separate observers, and consensus was

  20. High-contrast mammography with a moving grid: assessment of clinical utility

    International Nuclear Information System (INIS)

    Sickles, E.A.; Weber, W.N.

    1986-01-01

    Mammography techniques using moving grids produce superior breast images in many patients but result in increased radiation dose. This prospective controlled study of 1000 unselected screen-film mammography patients identifies a subset of women who are most likely to benefit from higher-dose grid-assisted techniques. In approximately 60% of the patients, the increased contrast of grid films produced a noticeable improvement in overall image quality. In only 20% of cases did this translate into clinically useful information, however, usually resulting in an increased level of confidence in interpretation. In virtually all the cases in which grid images aided mammographic diagnosis, the patients were women having more than 50% dense fibroglandular tissue or compressed breast thickness greater than 6 cm (only 37% of the study population). We suggest that the use of grid techniques be restricted to patients with such dense or thick breasts, because only in these women can the increase in radiation dose be justified

  1. At what age should screening mammography be recommended for Asian women?

    Science.gov (United States)

    Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi

    2015-07-01

    Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40-49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  2. Time for a re-evaluation of mammography in the young? Results of an audit of mammography in women younger than 40 in a resource restricted environment.

    Science.gov (United States)

    Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin

    2011-08-01

    Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.

  3. Continuous-flow leaching studies of crushed and cored SYNROC

    International Nuclear Information System (INIS)

    Coles, D.G.; Bazan, F.

    1982-01-01

    Both crushed (150- to 300- μm) and cored (1,8- mm-diam) samples of SYNROC have been leached with single-pass continuous-flow leaching equipment. Crushed samples of cesium-hollandite were also leached in a similar experiment. Temperatures used were 25 0 and 75 0 C and leachates were 0.03 N NaHCO 3 and distilled water. Leaching rates from SYNROC-C were ranked cesium > strontium greater than or equal to calcium > barium > zirconium. A comparison of leaching rates is made between crushed SYNROC, cored SYNROC, and Pacific Northwest Laboratory 76-68 glass beads. This comparison depends on how the surface areas are determined for each sample. Based on geometric surface areas for SYNROC cores and glass beads, cesium leach rates from SYNROC compare well with both sodium and neptunium leached from the glass. The other elements leached from SYNROC are lower than sodium and neptunium leached from glass. They also vary for each element, while glass shows nearly the same leach rate for both sodium and neptunium

  4. Continuous-flow leaching studies of crushed and cored SYNROC

    International Nuclear Information System (INIS)

    Coles, D.G.; Bazan, F.

    1981-01-01

    Both crushed (150 to 300 μm) and cored (1.8 mm diameter) samples of SYNROC have been leached with the single-pass continuous-flow leaching equipment. Crushed samples of Cs-hollandite were also leached in a similar experiment. Temperatures used were 25 and 75 0 C and leachates were 0.03 N NaHCO 3 and distilled water. Leaching rates from SYNROC C were ranked Cs > Sr greater than or equal to Ca > Ba > Zr. A comparison of leaching rates is made between crushed SYNROC, cored SYNROC, and PNL 76-68 glass beads. This comparison depends on how the surface areas are determined for each sample. Based on geometric surface areas for SYNROC cores and glass beads Cs leach rates from SYNROC compare well with both Na and Np leached from the glass. The other elements leached from SYNROC are lower than Na and Np leached from glass. They also vary for each element while glass shows nearly the same leach rate for both Na and Np

  5. Situational quality evaluation of mammography services at state of Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Joana, Georgia S.; Oliveira, Mauricio de; Andrade, Mauricio C. de; Cesar, Adriana C.Z.; Peixoto, Joao E.

    2011-01-01

    Breast cancer is the leading cause of cancer deaths in women. Currently, the most effective method for early detection of this cancer is the mammography, and to achieve the standard definition and contrast, the whole system of imaging must operate under optimal conditions. This paper presents the results of the assessment of mammography centers in the state of Minas Gerais, which was held with the aim of supporting the actions of the State Program of Quality Control in Mammography. These results indicated that less than half of mammography achieved the minimum standard of image quality, endorsing the need of a monitoring more efficient and effective, which led to the establishment, in Minas Gerais, of the monthly monitoring of image quality in mammography. (author)

  6. Seismic tipping analysis of a spent nuclear fuel shipping cask sitting on a crush pad

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Hawkes, B.D.

    1998-04-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of an accidentally dropped spent nuclear fuel shipping cask into a 44 ft. deep cask unloading pool. Conventional analysis techniques available for evaluating a cask for tipping due to lateral seismic forces assume that the cask rests on a rigid surface. In this analysis, the cask (110 tons) sits on a stainless steel encased (0.25 in. top plate), polyurethane foam (4 ft. thick) crush pad. As the cask tends to rock due to horizontal seismic forces, the contact area between the cask and the crush pad is reduced, increasing the bearing stress, and causing the pivoting corner of the cask to depress into the crush pad. As the crush pad depresses under the cask corner, the pivot point shifts from the corner toward the cask center, which facilitates rocking and potential tipping of the cask. Subsequent rocking of the cask may deepen the depression, further contributing to the likelihood of cask tip over. However, as the depression is created, the crush pad is absorbing energy from the rocking cask. Potential tip over of the cask was evaluated by performing a non-linear, dynamic, finite element analysis with acceleration time history input. This time history analysis captured the effect of a deforming crush pad, and also eliminated conservatisms of the conventional approaches. For comparison purposes, this analysis was also performed with the cask sitting on a solid stainless steel crush pad. Results indicate that the conventional methods are quite conservative relative to the more exacting time history analysis. They also indicate that the rocking motion is less on the foam crush pad than on the solid stainless steel pad

  7. Pulmonary Problems among Quarry Workers of Stone Crushing Industrial Site at Umuoghara, Ebonyi State, Nigeria

    Directory of Open Access Journals (Sweden)

    AN Nwibo

    2012-08-01

    Full Text Available Background: Respiratory problem is one of the major health hazards in dust-exposed workers; it is a major cause of morbidity and mortality all over the world. Objective: To determine the prevalence of respiratory problems and lung function impairment among quarry workers in Ebonyi State, Nigeria. Methods: Respiratory problems and lung function were studied in 403 quarry workers aged 10–60 years. Respiratory problems were investigated with a questionnaire based on international models adapted for the study population. Lung function was assessed by spirometry and chest roentgenography. Results: The respiratory problems found were chest pain (47.6%, occasional cough (40.7%, occasional shortness of breath (6.5% and wheezing (5.2%. The mean±SD FEV1 and FVC values were significantly decreased with length of exposure—respectively, 3.52±0.77 and 3.91±0.72 L for 10 years of exposure. Moreover, the mean±SD FEV1 and FVC values of smoker (3.37±0.81 and 3.56±1.02 L, respectively were significantly (p<0.05 lower than that of non-smokers (3.68±1.02 and 3.89±0.99 L, respectively working in the quarry site. Conclusion: Chronic exposure to dust due to stone quarrying may increase the risk of respiratory problems and impaired lung function—cigarette smokers are at higher risk.

  8. Calculation of density and permeability of compacted crushed salt within an engineered shaft sealing system

    International Nuclear Information System (INIS)

    Loken, M.; Statham, W.

    1997-01-01

    Crushed salt from the host Salado Formation is proposed as a sealing material in one component of a multicomponent seal system design for the shafts of the Waste Isolation Pilot Plant (WIPP), a mined geological repository for storage and disposal of transuranic radioactive wastes located near Carlsbad, New Mexico. The crushed salt will be compacted and placed at a density approaching 90% of the intact density of the host Salado salt. Creep closure of the shaft will further compact the crushed salt over time, thereby reducing the crushed-salt permeability from the initial state and creating an effective long-term seal. A structural model and a fluid flow model have been developed to provide an estimate of crushed-salt reconsolidation rate as a function of depth, time, and pore pressure. Model results are obtained in terms of crushed-salt permeability as a function of time and depth within the salt column. Model results indicate that average salt column permeability will be reduced to 3.3 x 10 -20 m 2 in about 100 years, which provides for an acceptable long-term seal component

  9. Factors influencing elderly women's mammography screening decisions: implications for counseling.

    Science.gov (United States)

    Schonberg, Mara A; McCarthy, Ellen P; York, Meghan; Davis, Roger B; Marcantonio, Edward R

    2007-11-16

    Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65-79. Telephone surveys of 107 women aged 80+ and 93 women aged 65-79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate). The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3%) had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65-79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65-79). While a doctor's recommendation is the most important factor influencing elderly women's mammography screening decisions, habit and reassurance

  10. Gallic acid and exercise training improve motor function, nerve conduction velocity but not pain sense reflex after experimental sciatic nerve crush in male rats.

    Science.gov (United States)

    Hajimoradi, Maryam; Fazilati, Mohammad; Gharib-Naseri, Mohammad Kazem; Sarkaki, Alireza

    2015-01-01

    The aim of present study was to evaluate the effects of oral administration of gallic acid (GA) for 21 days alone and in combination with exercise on nerve conduction velocity and sensory and motor functions in rats with sciatic nerve crush. Seventy adult male Wistar rats (250-300 g) were divided randomly into 7 groups with 10 in each: 1) Control (Cont), 2) Crushed + Vehicle (Cr +Veh), 3-5) Crushed + gallic acid (Cr+GA) (50, 100, and 200 mg/kg/2 mL, orally), 6) Crushed + exercise (Cr+Exe), and 7) Crushed + exercise + effective dose of gallic acid (Cr+Exe +GA200) for 21 days. In order to establish an animal model of sciatic nerve crush, equivalent to 7 kg of force pressed on 2-3 mm of sciatic nerve for 30 s, three times with 30 s intervals. Pain sense reflex in hot plate, motor coordination in rotarod, and sciatic nerve conduction velocity (SNCV) in all groups were tested. Data were analyzed using one-way ANOVA followed by Tukey's post hoc test and preflex latency was not changed in treated groups. Motor coordination and SNCV were improved in groups Cr+GA200 and Cr+Exe + GA200 (p<0.05, p<0.01 vs. Cr+Veh). GA, dose-dependently, may have therapeutic potential to improve the peripheral nerve degeneration, which is most likely related, at least in part, to its antioxidant and therapeutic properties.

  11. Production and characterization of composite stone; Processamento e caracterizacao de pedra composta

    Energy Technology Data Exchange (ETDEWEB)

    Leirose, G.D. [Universidade Federal de Ouro Preto (UFOP), MG (Brazil); Lameiras, F.S., E-mail: danileirose@yahoo.com.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2012-07-01

    Composite stone is a product similar to natural granite or marble, produced with particles of these materials. This material is used like natural stone as lining. The fabrication of artificial stones using residues of banded iron formations is a promising alternative to its actual destination (storage in dam). This research aims the characterization of composite stone to prove the efficacy of this kind of processing. It was used first, natural quartz as a raw material. The patterns of the samples were confirmed by IR spectra and XRD patterns, ensuring the reproducibility of processing applied. Moreover, this material is homogeneous, with low porosity and high flexural strength, confirmed by its structural characterization. Thus, it can be affirmed that the process chosen is suitable, enabling the application of this methodology to the use of waste. (author)

  12. Rayleigh imaging in spectral mammography

    Science.gov (United States)

    Berggren, Karl; Danielsson, Mats; Fredenberg, Erik

    2016-03-01

    Spectral imaging is the acquisition of multiple images of an object at different energy spectra. In mammography, dual-energy imaging (spectral imaging with two energy levels) has been investigated for several applications, in particular material decomposition, which allows for quantitative analysis of breast composition and quantitative contrast-enhanced imaging. Material decomposition with dual-energy imaging is based on the assumption that there are two dominant photon interaction effects that determine linear attenuation: the photoelectric effect and Compton scattering. This assumption limits the number of basis materials, i.e. the number of materials that are possible to differentiate between, to two. However, Rayleigh scattering may account for more than 10% of the linear attenuation in the mammography energy range. In this work, we show that a modified version of a scanning multi-slit spectral photon-counting mammography system is able to acquire three images at different spectra and can be used for triple-energy imaging. We further show that triple-energy imaging in combination with the efficient scatter rejection of the system enables measurement of Rayleigh scattering, which adds an additional energy dependency to the linear attenuation and enables material decomposition with three basis materials. Three available basis materials have the potential to improve virtually all applications of spectral imaging.

  13. Potential Cost Savings of Contrast-Enhanced Digital Mammography.

    Science.gov (United States)

    Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A

    2017-06-01

    The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.

  14. Mammography in Norway: Image quality and total performance

    International Nuclear Information System (INIS)

    Olsen, J.B.; Skretting, A.; Widmark, A.

    1997-04-01

    This report describes a method for assessing the total performance in mammography based on Receiver Operating Characteristic (ROC) analysis. In the time period from December 1993 to March 1994 the method was applied to assess the total performance of all the 45 Norwegian mammography laboratories operative at that time. Image quality characteristics in each laboratory was established by use of well-known phantoms

  15. The role of Facebook in Crush the Crave, a mobile- and social media-based smoking cessation intervention: qualitative framework analysis of posts.

    Science.gov (United States)

    Struik, Laura Louise; Baskerville, Neill Bruce

    2014-07-11

    smoking cessation posts (81/214, 37.9%) compared to the marketing Crush the Crave posts (11/64, 17%). With the exception of 4 posts, a moderator posted all the original posts. In addition, although 56.00% (18,937/33,815) of Crush the Crave Facebook page users were men, only 19.8% (55/278) of the reply posts were made by men. Finally, men were found to be more likely to express sarcasm or make strong assertions about quitting smoking and Crush the Crave than women. The CTC Facebook page presents as a unique platform for supporting young adult smoking cessation at all stages of the cessation process. The findings of this study indicate that social networking sites, especially Facebook, warrant inclusion in tobacco control efforts directed towards young adults. Research on effectiveness of the Facebook page for quitting smoking is needed.

  16. Object characterization simulator for estimating compressed breast during mammography

    International Nuclear Information System (INIS)

    Pinheiro, Luciana de J.S.; Rio, Margarita Chevalier del

    2011-01-01

    The measurement of the thickness of a compressed breast during the mammography test is necessary in order to calculate the glandular dose in mammography procedures, in an analysis of risk/benefit, given that the target organ in these procedures is highly sensitive to ionising radiation. However, mammography is a test of utmost importance in diagnosis. In theory, it may be possible to calculate the thickness of the compressed breast through the measurements of the focus object distance by using projections of radio opaque objects fixed to the compression tray. The facilities of the Laboratory of Applied Radioprotection to Mammography - LARAM were used for this study, as well as breast simulators with well defined thickness, in the assembly of the techniques for the measurement of the thickness of the compressed breast. The results showed that it is possible to determine this thickness through calculations and simulators through this method which is susceptible to be adequate to the dosimetry. (author)

  17. The utility of the gammagraph with 99mTc-MIBI as a complement to mammography in patients with a suspicion of breast cancer in a Havanna, Cuba health area

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Pena Coego, Andria; Coca Perez, Marco A; Batista Cuellar, Juan F

    2006-01-01

    To determine the utility of the gammagraphy with 99m Tc-MIBI, like complement of the mammography, in the study of patient with breast cancer suspicion, we study 22 patients with nodules of breast, in an area of health, by means of ultrasound, mammography, gammagraphy and biopsy, this it constituted the gold standard. The 68.2% of the patients presented carcinomas of breast and 31.8% injures benign. The gammagraphy showed values of sensibility, specificity and accuracy diagnoses superiors to the remaining techniques employees. Metastasis in axillary's nodule existed in 46.6% of the cases with breast cancer. Four (57.1%) they were detected by the gammagraphy. Conclusions: The gammagraphy with 99m Tc-MIBI was of great utility like complement of the mammography, for the study of patient with breast cancer, it was specially useful in the cases reported as suspects and uncertain for the mammography and in the detection of axillaries nodules (au)

  18. Estimation of patient dose in mammography screening examinations

    International Nuclear Information System (INIS)

    Suzuki, S.; Fujii, S.; Orito, T.; Asada, Y.; Koga, S.; Horita, K.; Kido, C.

    1996-01-01

    Mammography is one of the most effective examinations for detecting breast carcinoma. Although the dose is usually much higher than that in other types of X-ray examination, that is accepted by the patient because for fears of suffering cancer. Benefit of relatively high doses derived from mammographic examinations is considered to well exceed the risk of cancer induction by radiation exposure. The purpose of this study is to investigate patient dose of mammography in Japan by questionnaire sent to 531 institutions selected from whole Japan and direct measurements carried out in 28 hospitals in Aichi Prefecture. The user's guide in mammography published by NCRP and Quality Assurance Program of American College of Radiology were used to assess the exposure and image quality of mammogram. (author)

  19. Dual-energy contrast-enhanced spectral mammography (CESM).

    Science.gov (United States)

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  20. Programmatic Considerations to Reduce the Risk of Adverse Renal Stone Events in Spaceflight

    Science.gov (United States)

    Antonsen, Erik; Pietrzyk, Robert

    2017-01-01

    Introduction: Microgravity exposure may alter the likelihood that astronauts will experience renal stones. The potential risk includes both acute and chronic health issues, with the potential for significant impact on mission objectives. Methods: To understand the role of the NASA's Human Research Program (HRP) research agenda in both preventing and addressing renal stones in spaceflight, current astronaut epidemiologic data and a summary of programmatic considerations are reviewed. Results: Although there has never been a symptomatic renal stone event in a U.S. crewmember during spaceflight, urine chemistry has been altered - likely due to induced changes in renal physiology as a result of exposure to microgravity. This may predispose astronauts to stone formation, leading the HRP to conduct and sponsor research to: 1) understand the risk of stone formation in space; 2) prevent stones from forming; and 3) address stones that may form by providing novel diagnostic and therapeutic approaches. Discussion: The development of a renal stone during spaceflight is a significant medical concern that requires the HRP to minimize this risk by providing the ability to prevent, diagnose, monitor and treat the condition during spaceflight. A discussion of the risk as NASA understands it is followed by an overview of the multiple mitigations currently under study, including novel ultrasound techniques for stone detection and manipulation, and how they may function as part of a larger exploration medical system.

  1. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme.

    Science.gov (United States)

    Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E

    2014-07-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.

  2. Bi-directional x-ray phase-contrast mammography.

    Directory of Open Access Journals (Sweden)

    Kai Scherer

    Full Text Available Phase-contrast x-ray imaging is a promising improvement of conventional absorption-based mammography for early tumor detection. This potential has been demonstrated recently, utilizing structured gratings to obtain differential phase and dark-field scattering images. However, the inherently anisotropic imaging sensitivity of the proposed mono-directional approach yields only insufficient diagnostic information, and has low diagnostic sensitivity to highly oriented structures. To overcome these limitations, we present a two-directional x-ray phase-contrast mammography approach and demonstrate its advantages by applying it to a freshly dissected, cancerous mastectomy breast specimen. We illustrate that the two-directional scanning procedure overcomes the insufficient diagnostic value of a single scan, and reliably detects tumor structures, independently from their orientation within the breast. Our results indicate the indispensable diagnostic necessity and benefit of a multi-directional approach for x-ray phase-contrast mammography.

  3. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Lobbes, Marc B.I.; Wildberger, Joachim E. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); Nelemans, Patty J. [Maastricht University, Department of Epidemiology, Maastricht (Netherlands); Roozendaal, Lori van; Heuts, Esther [Maastricht University Medical Center, Department of Surgical Oncology, Maastricht (Netherlands); Smidt, Marjolein L. [Maastricht University Medical Center, Department of Surgical Oncology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2014-07-15

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0 % (+3.1 %), specificity to 87.7 % (+45.7 %), PPV to 76.2 % (+36.5 %) and NPV to 100.0 % (+2.9 %) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. (orig.)

  4. Compliance with European Guidelines for Diagnostic Mammography in a Decentralized Health-Care Setting

    International Nuclear Information System (INIS)

    Jensen, A.; Mikkelsen, G.J.; Vestergaard, M.; Lynge, E.; Vejborg, I.

    2005-01-01

    Purpose: To evaluate the compliance of Danish mammography clinics with requirements concerning organization, activity volume, and assessment procedures from two European guidelines for quality assurance in diagnostic mammography (EUSOMA and EUREF). Material and Methods: We used individual records on all diagnostic mammographies performed in Denmark in 2000, and questionnaires given to Danish mammography clinics in 2000, 2002, and 2004. Results: The study showed a marked centralization of the diagnostic activity from 2000 to 2004 to a smaller number of public breast assessment centers with full multidisciplinary breast assessment. However, a relatively large number of these centers did not comply with the activity volume requirement of 2000 mammograms per clinic per year. The number of private diagnostic mammography clinics performing basic diagnostic mammography has remained fairly stable in the period 2000 to 2004. Compared with public breast assessment centers, the private diagnostic mammography clinics had a lower compliance with activity volume requirements. Conclusion: A marked proportion of Danish public breast assessment centers operate with less than optimal activity volume, suggesting that further centralization would be appropriate. The situation in private diagnostic mammography clinics may cause concern, as our study showed that the majority of these clinics did not meet the activity volume requirements

  5. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme

    International Nuclear Information System (INIS)

    Lobbes, Marc B.I.; Wildberger, Joachim E.; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C.; Nelemans, Patty J.; Roozendaal, Lori van; Heuts, Esther; Smidt, Marjolein L.

    2014-01-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0 % (+3.1 %), specificity to 87.7 % (+45.7 %), PPV to 76.2 % (+36.5 %) and NPV to 100.0 % (+2.9 %) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. (orig.)

  6. Quality Assessment of Urinary Stone Analysis

    DEFF Research Database (Denmark)

    Siener, Roswitha; Buchholz, Noor; Daudon, Michel

    2016-01-01

    After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction......, fulfilled the quality requirements. According to the current standard, chemical analysis is considered to be insufficient for stone analysis, whereas infrared spectroscopy or X-ray diffraction is mandatory. However, the poor results of infrared spectroscopy highlight the importance of equipment, reference...... spectra and qualification of the staff for an accurate analysis of stone composition. Regular quality control is essential in carrying out routine stone analysis....

  7. Analysis of medical exposures in digital mammography

    International Nuclear Information System (INIS)

    Oliveira, Sergio R.; Mantuano, Natalia O.; Albrecht, Afonso S.

    2014-01-01

    Currently, the use of digital mammography in the early diagnosis of breast cancer is increasingly common due to the production of high definition image that allows to detect subtle changes in breast images profiles. However it is necessary to be an improvement of the technique used since some devices offer minimization parameters of entrance dose to the skin. Thus, this study seeks to examine how the qualification of technical professionals in radiology interferes with the use of the techniques applied in mammography. For this, survey was carried out in a hospital in the city of Rio de Janeiro, which evaluated the scans of 1190 patients undergoing routine mammography (It is considered routinely the 4 basic exhibitions: with 2 flow skull and 2 medium oblique side, excluding repeats and supplements) in 2013. The medical exposures analyzed obtained from a single full digital equipment, model Senographe DS were compared with three different procedures performed by professionals in mammography techniques. The images were classified according to exposure techniques available in the equipment: Standard (STD), contrast (CNT) and dose (dose), and to be selected as breast density of the patient. Comparing the variation of the radiographic technique in relation to the professional who made the exhibition, what is observed is that the professional B presented the best conduct in relation to radiological protection, because she considered breast density in the choice of technical equipment parameter. The professional A, which is newly formed, and C, which has more service time, almost did not perform variations in the pattern of exposure, even for different breast densities. Thus, we can conclude that there is a need to update the professionals so that the tools available of dose limitation and mamas variability to digital mammography are efficiently employed in the service routine and thus meet the requirements of current legislation

  8. Adherence to Mammography Screening Guidelines Among Transgender Persons and Sexual Minority Women.

    Science.gov (United States)

    Bazzi, Angela Robertson; Whorms, Debra S; King, Dana S; Potter, Jennifer

    2015-11-01

    We used retrospective (2012-2013) chart review to examine breast cancer screening among transgender persons and sexual minority women (n = 1263) attending an urban community health center in Massachusetts. Transgender were less likely than cisgender patients and bisexuals were less likely than heterosexuals and lesbians to adhere to mammography screening guidelines (respectively, adjusted odds ratios = 0.53 and 0.56; 95% confidence intervals = 0.31, 0.91 and 0.34, 0.92) after adjustment for sociodemographics. Enhanced cancer prevention outreach is needed among gender and sexual minorities.

  9. Colorado Yule Marble; building stone of the Lincoln Memorial

    Science.gov (United States)

    McGee, Elaine S.

    1999-01-01

    The Colorado Yule marble, quarried in Marble, Colo., is a very pure white marble, and it has been widely acclaimed for its quality and purity. This marble has been used for many prominent buildings; one of the most notable is the Lincoln Memorial in Washington, D.C., built nearly 80 years ago. Although most of the marble in the memorial appears to be in very good condition, some of the stones have developed pronounced surficial roughness and show a significant loss of carved details and rounded edges compared with adjacent stones. Because adjacent blocks of marble receive nearly identical exposure to weathering agents that cause deterioration of the marble, it seems very likely that this pronounced difference in durability of adjacent stones arises from some inherent characteristic of the marble. The Colorado Yule marble is a nearly pure calcite marble with minor inclusions of mica, quartz, and feldspar. Compositions of the calcite and the inclusion phases in the marble are typical for those phases. The calcite grains that compose the marble are irregularly shaped and range from 100 to 600 micrometers in diameter. The texture of the marble is even, with a slight preferred directional elongation that is visible when the marble is cut in certain directions. Physical tests of the marble show that its strength is comparable to that of other marbles typically used in buildings. Variations in the durability of the marble, like those seen at the Lincoln Memorial, are not related to variations in calcite composition or to the presence of inclusions in the marble. Most likely, the variations arise from differences in the calcite grain boundaries and the degree to which the grains interlock with one another. Weak grain boundaries that permit water or solutions to penetrate into the marble and dissolve the calcite grains at their edges cause the marble to disaggregate or ?sugar.? Subtle differences in texture that occur in the marble from various parts of the quarry probably

  10. Study on characteristics of printed circuit board liberation and its crushed products.

    Science.gov (United States)

    Quan, Cui; Li, Aimin; Gao, Ningbo

    2012-11-01

    Recycling printed circuit board waste (PCBW) waste is a hot issue of environmental protection and resource recycling. Mechanical and thermo-chemical methods are two traditional recycling processes for PCBW. In the present research, a two-step crushing process combined with a coarse-crushing step and a fine-pulverizing step was adopted, and then the crushed products were classified into seven different fractions with a standard sieve. The liberation situation and particle shape in different size fractions were observed. Properties of different size fractions, such as heating value, thermogravimetric, proximate, ultimate and chemical analysis were determined. The Rosin-Rammler model was applied to analyze the particle size distribution of crushed material. The results indicated that complete liberation of metals from the PCBW was achieved at a size less than 0.59 mm, but the nonmetal particle in the smaller-than-0.15 mm fraction is liable to aggregate. Copper was the most prominent metal in PCBW and mainly enriched in the 0.42-0.25 mm particle size. The Rosin-Rammler equation adequately fit particle size distribution data of crushed PCBW with a correlation coefficient of 0.9810. The results of heating value and proximate analysis revealed that the PCBW had a low heating value and high ash content. The combustion and pyrolysis process of PCBW was different and there was an obvious oxidation peak of Cu in combustion runs.

  11. Significance of lower-pole pelvicaliceal anatomy on stone clearance after shockwave lithotripsy in nonobstructive isolated renal pelvic stones.

    Science.gov (United States)

    Sozen, Sinan; Kupeli, Bora; Acar, Cenk; Gurocak, Serhat; Karaoglan, Ustunol; Bozkirli, Ibrahim

    2008-05-01

    To investigate the probable effect of lower-pole pelvicaliceal anatomy on stone clearance after shockwave lithotripsy (SWL) in patients with nonobstructive renal pelvic stones. The clinical records of patients with isolated renal pelvic stones who underwent SWL between 1996 and 2005 were reviewed. After excluding patients with obstruction leading to dilatation, major anatomic abnormalities, noncalcium stones, metabolic abnormalities, history of recurrent stone disease, multiple stones, and previous renal surgery, 153 patients were enrolled in the study. Lower pole infundibulopelvic angle (IPA) and infundibular length and width were measured from intravenous urography. Patients were classified into three groups according to stone burden (group 1, renal pelvis, and both in 50 (32.6%), 29 (18.9%), and 8 (5.2%) patients, respectively. There was no statistically significant difference in pelvicaliceal anatomic features except narrower IPA (P=0.02) in group 1 patients with residual stones. The falling of stone fragments to the lower calix in spite of the ureter whether clinically significant or not after SWL of pelvic stones initially seems to be related to stone burden rather than lower caliceal anatomy. However, existence of a more narrow IPA in group 1 patients with residual fragments led us to believe that lower-pole IPA can play a role in stone clearance, especially for smaller stones, probably because of smaller residual fragment size or the more mobile nature of the primary stone.

  12. Investigations on stone fragmentation in different extracorporeal shock wave lithotripsy sound fields in vitro

    Science.gov (United States)

    Dreyer, Thomas; Liebler, Marko; Riedlinger, Rainer

    2005-04-01

    The mechanism of stone fragmentation in ESWL applications is still under investigation. Devices showing a wide focal area and comparably low focal pressure amplitudes have been reported to disintegrate stones more efficiently as current clinical devices with high amplitudes and small focal areas. From this the question is raised whether the underlying different physical mechanisms or treatment issues, like stone localization and movement, are responsible for these results. In this paper fragmentation experiments in vitro with different stone types (e.g., HMT and BegoStone, 15 mm diam.) under different sound fields are presented. A self focusing piezoelectric transducer with a small focal area and peak pressure amplitudes of up to 125 MPa is used. The number of pulses was counted until a complete fragmentation through a 2 mm wire mesh is reached. In order to simulate wide-focus low-pressure conditions, the stones were placed in the prefocal region. Fragmentation results are compared to the case of focal placement. Initial breakage occurs earlier in the prefocal region for the HMT stones, whereas complete fragmentation is reached significantly earlier in the focus for all stone types.

  13. A computerized expert system for mammography

    International Nuclear Information System (INIS)

    Jackson, V.P.; Dines, K.A.; Bassett, L.W.

    1988-01-01

    The authors have developed a computer-based expert system to aid in the interpretation of mammograms, breast sonograms, and clinical findings. The radiologist enters clinical and image data into the artificial intelligence system and receives a prediction of the etiology of lesions seen on breast imaging studies. This prototype interactive system has undergone preliminary clinical testing and evaluation. Ultimately, a more refined and complex system will be of value in mammography education, for general radiologists without ready access to mammography experts, for paramedical personnel, and for all mammographers in need of a breast imaging database and reporting systems

  14. Use of the probability of stone formation (PSF) score to assess stone forming risk and treatment response in a cohort of Brazilian stone formers

    OpenAIRE

    Turney, Benjamin; Robertson, William; Wiseman, Oliver; Amaro, Carmen Regina P. R.; Leitão, Victor A.; Silva, Isabela Leme da; Amaro, João Luiz

    2014-01-01

    Introduction: The aim was to confirm that PSF (probability of stone formation) changed appropriately following medical therapy on recurrent stone formers.Materials and Methods: Data were collected on 26 Brazilian stone-formers. A baseline 24-hour urine collection was performed prior to treatment. Details of the medical treatment initiated for stone-disease were recorded. A PSF calculation was performed on the 24 hour urine sample using the 7 urinary parameters required: voided volume, oxalate...

  15. Cask crush pad analysis using detailed and simplified analysis methods

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Hawkes, B.D.

    1997-01-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of a hypothetically dropped spent nuclear fuel shipping cask into a 44-ft. deep cask unloading pool at the Fluorinel and Storage Facility (FAST). This facility, located at the Idaho Chemical Processing Plant (ICPP) at the Idaho national Engineering and Environmental Laboratory (INEEL), is a US Department of Energy site. The basis for this study is an analysis by Uldrich and Hawkes. The purpose of this analysis was to evaluate various hypothetical cask drop orientations to ensure that the crush pad design was adequate and the cask deceleration at impact was less than 100 g. It is demonstrated herein that a large spent fuel shipping cask, when dropped onto a foam crush pad, can be analyzed by either hand methods or by sophisticated dynamic finite element analysis using computer codes such as ABAQUS. Results from the two methods are compared to evaluate accuracy of the simplified hand analysis approach

  16. Comparison of TLD air kerma measurements in mammography

    International Nuclear Information System (INIS)

    Pernicka, F.

    2002-01-01

    The mammography examination is usually targeted at asymptomatic women so the narrow balance between benefit and undesirable effects is important. During the past few decades there have been significant advances in the equipment used for mammography. Even when the latest equipment and imaging systems are used, there is considerable variation from centre-to-centre in the choice of imaging parameters and techniques. There may be quite large differences in image quality and breast dose among the centres. A Co-ordinated Research Programme on 'Image quality and patient dose optimization in mammography in Eastern European Countries' was conducted by the IAEA, aiming at defining a methodology for the implementation of a quality assurance (QA) programme in mammography and at exercising the assessment of image quality and patient doses in a sample of hospitals in East European countries. Selected mammography clinics from Czech Republic, Hungary, Poland, Romania and Slovakia participate in the project. The teams consisted of experienced clinicians and physicists. They were supported by a group of experts (clinicians and medical physicists) from France, Italy and Spain. As an outcome of the project, improvements in these indicators (image quality and patient dose) after the implementation of the QA programme are expected. A comparison of dosimetry systems has been organized to assure that dosimetry measurements done in the frame of the project are comparable and traceable to the international measurement system. All five East European countries plus Spain took part in the exercise. The thermoluminescent (TL) method was selected for the comparison

  17. The use of ultrasonography and digital mammography in women under 40 years with symptomatic breast cancer: a 7-year Irish experience.

    Science.gov (United States)

    Redmond, C E; Healy, G M; Murphy, C F; O'Doherty, A; Foster, A

    2017-02-01

    Breast cancer in women under 40 years of age is rare and typically presents symptomatically. The optimal imaging modality for this patient group is controversial. Most women undergo ultrasonography with/without mammography. Young women typically have dense breasts, which can obscure the features of malignancy on film mammography, however, initial studies have suggested that digital mammography may have a more accurate diagnostic performance in younger women. Ultrasound generally performs well in this age group, although it is poor at detecting carcinoma in situ (DCIS). To evaluate the comparative diagnostic performance of ultrasonography and digital mammography in the initial diagnostic evaluation of women under 40 years of age with symptomatic breast cancer. Retrospective review of all women under the age of 40 years managed at our symptomatic breast cancer unit from January 2009 to December 2015. There were 120 patients that met the inclusion criteria for this study. The sensitivity of ultrasonography and digital mammography for breast cancer in this patient group was 95.8 and 87.5 %, respectively. The patients with a false negative mammographic examination were more likely to have dense breasts (p breast cancer in women under the age of 40 years, however, the results show that digital mammography has an important complimentary role in the comprehensive assessment of these patients, particularly in the diagnosis of DCIS.

  18. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  19. Bariatric Surgery and Stone Disease

    Science.gov (United States)

    Lieske, John C.; Kumar, Rajiv

    2008-09-01

    Bariatric surgery is an effective treatment strategy for patients with morbid obesity that can result in effective weight loss, resolution of diabetes mellitus and other weight related complications, and even improved mortality. However, it also appears that hyperoxaluria is common after modern bariatric surgery, perhaps occurring in up to 50% of patients after Rouxen-Y gastric bypass. Although increasing numbers of patients are being seen with calcium oxalate kidney stones after bariatric surgery, and even a few with oxalosis and renal failure, the true risk of these outcomes remains unknown. The mechanisms that contribute to this enteric hyperoxaluria are also incompletely defined, although fat malabsorption may be an important component. Since increasing numbers of these procedures are likely to be performed in the coming years, further study regarding the prevalence and mechanisms of hyperoxaluria and kidney stones after bariatric surgery is needed to devise effective methods of treatment in order to prevent such complications.

  20. Patients with Urinary Incontinence Appear More Likely to Develop Upper Urinary Tract Stones: A Nationwide, Population-Based Study with 8-Year Follow-Up

    Science.gov (United States)

    Chung, Hsiao-Jen; Lin, Alex Tong-Long; Lin, Chih-Chieh; Chen, Tzeng-Ji; Chen, Kuang-Kuo

    2016-01-01

    This study aimed to investigate associations between primary urinary incontinence and development of upper urinary tract stones in a nationwide population in Taiwan. Data of 1,777 adults with primary urinary incontinence and 26,655 controls (groups A, B, and C) without urinary incontinence at study inception were retrieved from the National Health Insurance System database in Taiwan and were analyzed retrospectively. No enrolled subjects had previous diagnosis of upper urinary tract stones or spinal cord injury. All subjects were followed through end of 2009, with a minimum follow-up of 8 years. A greater percentage of study subjects (334/1777, 18.8%) developed upper urinary tract stones than that of control groups A (865/8885, 9.7%) and B (888/8885, 10%), and C (930/8885, 10.5%) (all p-values Urinary incontinence was associated with significantly increased risk of developing urinary tract stones (HR 1.99, 95% CI, 1.70–2.34, p urinary tract stones (both p-values urinary incontinence was still associated with a significantly increased risk of developing upper urinary tract stones (HR 1.99, 95% CI = 1.76–2.26, p urinary incontinence suggests that urinary incontinence is associated with a significantly increased risk of developing upper urinary tract stones. Study findings suggest that physicians treating patients with urinary incontinence should give attention to early detection of upper urinary tract stones. PMID:27536881

  1. Patients with Urinary Incontinence Appear More Likely to Develop Upper Urinary Tract Stones: A Nationwide, Population-Based Study with 8-Year Follow-Up.

    Science.gov (United States)

    Chung, Hsiao-Jen; Lin, Alex Tong-Long; Lin, Chih-Chieh; Chen, Tzeng-Ji; Chen, Kuang-Kuo

    2016-01-01

    This study aimed to investigate associations between primary urinary incontinence and development of upper urinary tract stones in a nationwide population in Taiwan. Data of 1,777 adults with primary urinary incontinence and 26,655 controls (groups A, B, and C) without urinary incontinence at study inception were retrieved from the National Health Insurance System database in Taiwan and were analyzed retrospectively. No enrolled subjects had previous diagnosis of upper urinary tract stones or spinal cord injury. All subjects were followed through end of 2009, with a minimum follow-up of 8 years. A greater percentage of study subjects (334/1777, 18.8%) developed upper urinary tract stones than that of control groups A (865/8885, 9.7%) and B (888/8885, 10%), and C (930/8885, 10.5%) (all p-values Urinary incontinence was associated with significantly increased risk of developing urinary tract stones (HR 1.99, 95% CI, 1.70-2.34, p urinary tract stones (both p-values urinary incontinence was still associated with a significantly increased risk of developing upper urinary tract stones (HR 1.99, 95% CI = 1.76-2.26, p urinary incontinence suggests that urinary incontinence is associated with a significantly increased risk of developing upper urinary tract stones. Study findings suggest that physicians treating patients with urinary incontinence should give attention to early detection of upper urinary tract stones.

  2. Endoscopic Stone Measurement During Ureteroscopy.

    Science.gov (United States)

    Ludwig, Wesley W; Lim, Sunghwan; Stoianovici, Dan; Matlaga, Brian R

    2018-01-01

    Currently, stone size cannot be accurately measured while performing flexible ureteroscopy (URS). We developed novel software for ureteroscopic, stone size measurement, and then evaluated its performance. A novel application capable of measuring stone fragment size, based on the known distance of the basket tip in the ureteroscope's visual field, was designed and calibrated in a laboratory setting. Complete URS procedures were recorded and 30 stone fragments were extracted and measured using digital calipers. The novel software program was applied to the recorded URS footage to obtain ureteroscope-derived stone size measurements. These ureteroscope-derived measurements were then compared with the actual-measured fragment size. The median longitudinal and transversal errors were 0.14 mm (95% confidence interval [CI] 0.1, 0.18) and 0.09 mm (95% CI 0.02, 0.15), respectively. The overall software accuracy and precision were 0.17 and 0.15 mm, respectively. The longitudinal and transversal measurements obtained by the software and digital calipers were highly correlated (r = 0.97 and 0.93). Neither stone size nor stone type was correlated with error measurements. This novel method and software reliably measured stone fragment size during URS. The software ultimately has the potential to make URS safer and more efficient.

  3. Axial Crush of the Tubular Structure with Various Cee-Shaped Cross-Sections

    International Nuclear Information System (INIS)

    Afshar, Reza; Ali, Aidy; Sahari, B B; Bayat, M

    2011-01-01

    Tubular structure with various Cee-shaped cross sections is numerically investigated in order to find the centre of gravity (COG) under axial crush by using program code of ANSYS/LS-DYNA. A subroutine is developed using this code to obtain the COG of deformed shape, during and after crush deformation. The effect of wall thickness of the structure on displacement of COG is also studied. Subsequently, the effect of opening angle of Cee become more prominent as the wall thickness of the structure decreases and as the thickness increases, displacement of the COG in crush direction almost stabilizes for all opening angle of Cee in the range of (10 0 - 90 0 ). Furthermore, Variation of I yy of structure with thicker wall for different cases of applied weight is approximately identical. The value of mass moment of inertia with respect to X and Z axes through the model COG (I zx ) in comparison with I yy can be neglected in the case of axial crush along Y direction.

  4. [Commentary on the planned restructuring of mammography screening in Austria].

    Science.gov (United States)

    Vutuc, Christian; Haidinger, Gerald

    2011-08-01

    With regards to the planned reorganisation of screening mammography in Austria - from an opportunistic to an organised system - the problems related with such a change are depicted from an epidemiological point of view. We were able to demonstrate earlier that opportunistic screening mammography matches the results of controlled screening mammography in Finland and Sweden. Switching to a controlled system in Austria would - besides the need for a change in legislation - lead to enormous expenditures in terms of resources needed and moreover, it could be not evaluated for years.

  5. Fad diets and their effect on urinary stone formation.

    Science.gov (United States)

    Nouvenne, Antonio; Ticinesi, Andrea; Morelli, Ilaria; Guida, Loredana; Borghi, Loris; Meschi, Tiziana

    2014-09-01

    The influence of unhealthy dietary habits on urinary stone formation has been widely recognized in literature. Dietary advice is indeed the cornerstone prescription for prevention of nephrolithiasis as well. However, only a small amount of medical literature has addressed the influence of popular or fad diets, often self-prescribed for the management of obesity and overweight or for cultural beliefs, on the risk of kidney stones. Thereby in this paper we analyze the current knowledge on the effects of some popular diets on overall lithogenic risk. High-protein diets, like Dukan diet, raise some concerns, since animal proteins are able to increase urinary calcium and to decrease urinary citrate excretion, thus leading to a high overall lithogenic risk. Low-carbohydrate diets, like Atkins diet or zone diet, may have a protective role against kidney stone formation, but there are also evidences stating that this dietary approach may rise calciuria and decrease citraturia, since it is generally associated to a relatively high intake of animal proteins. Vegan diet can be harmful for urinary stone disease, especially for the risk of hyperuricemia and micronutrient deficiencies, even if only few studies have addressed this specific matter. On the other side, the benefits of a lacto-ovo-vegetarian diet on kidney stone prevention have been largely emphasized, provided that the intake of calcium and oxalate is balanced. Traditional Mediterranean diet should exert a protective effect on nephrolithiasis as well, even if specific studies have not been carried out yet. High phytate and antioxidant content of this diet have however demonstrated to be beneficial in preventing the formation of new or recurrent calculi. Anyway, at the current state of knowledge, the most effective dietary approach to prevent kidney stone disease is a mild animal protein restriction, a balanced intake of carbohydrates and fats and a high intake of fruit and vegetables. Other fundamental aspects

  6. Fad diets and their effect on urinary stone formation

    Science.gov (United States)

    Nouvenne, Antonio; Ticinesi, Andrea; Morelli, Ilaria; Guida, Loredana; Meschi, Tiziana

    2014-01-01

    The influence of unhealthy dietary habits on urinary stone formation has been widely recognized in literature. Dietary advice is indeed the cornerstone prescription for prevention of nephrolithiasis as well. However, only a small amount of medical literature has addressed the influence of popular or fad diets, often self-prescribed for the management of obesity and overweight or for cultural beliefs, on the risk of kidney stones. Thereby in this paper we analyze the current knowledge on the effects of some popular diets on overall lithogenic risk. High-protein diets, like Dukan diet, raise some concerns, since animal proteins are able to increase urinary calcium and to decrease urinary citrate excretion, thus leading to a high overall lithogenic risk. Low-carbohydrate diets, like Atkins diet or zone diet, may have a protective role against kidney stone formation, but there are also evidences stating that this dietary approach may rise calciuria and decrease citraturia, since it is generally associated to a relatively high intake of animal proteins. Vegan diet can be harmful for urinary stone disease, especially for the risk of hyperuricemia and micronutrient deficiencies, even if only few studies have addressed this specific matter. On the other side, the benefits of a lacto-ovo-vegetarian diet on kidney stone prevention have been largely emphasized, provided that the intake of calcium and oxalate is balanced. Traditional Mediterranean diet should exert a protective effect on nephrolithiasis as well, even if specific studies have not been carried out yet. High phytate and antioxidant content of this diet have however demonstrated to be beneficial in preventing the formation of new or recurrent calculi. Anyway, at the current state of knowledge, the most effective dietary approach to prevent kidney stone disease is a mild animal protein restriction, a balanced intake of carbohydrates and fats and a high intake of fruit and vegetables. Other fundamental aspects

  7. Simplified methods for the evaluation of the risk of forming renal stones and the follow-up of stone-forming propensity during the preventive treatment of stone-formation.

    Science.gov (United States)

    Grases, Fèlix; Costa-Bauzá, Antonia

    2016-02-01

    Renal lithiasis is a complex multifactorial disease in which recurrence is common. Thus, simple and reliable procedures are needed to evaluate patients with previous kidney stones to determine the risk of recurrence. In this paper we review simple biochemical procedures that can be used to determine the risk for renal stone formation when the stone is available or unavailable for analysis. Our present knowledge of renal lithiasis indicates that renal stones form due to several well-defined factors. Analysis of the renal stone itself can provide important information about clinical factors that require further investigation. When the stone is unavailable, it is necessary to perform a general evaluation of main urinary risk factors associated to renal stone formation, but this study should be complemented considering information related to direct familial antecedents, recidivant degree, radiological images, medical history, and life style habits. Finally, tools for patient follow-up of stone-forming propensity during the preventive treatment are discussed .

  8. Anxiety in mammography: mammographers' and clients' perspectives

    International Nuclear Information System (INIS)

    Galletta, S.; Joel, N.; Maguire, R.; Weaver, K.; Poulos, A.

    2003-01-01

    The aim of this study was to identify causes of anxiety experienced by mammographers and clients during mammography and strategies to decrease the anxiety generated by the mammographic procedure. Two questionnaires were distributed: one to mammographers in public and private centres within NSW, the other to women (clients) who have experienced mammography. Mammographers' and clients' rankings of causes of clients' anxiety demonstrated many similarities indicating the mammographers' acknowledgement of factors contributing to client anxiety. Thematic analysis provided important qualitative data concerning anxiety experienced by both mammographers and clients and the influence of mammographer and client behaviour on that anxiety. The results of this study have provided important new knowledge for mammographic practice and mammography education. By understanding the causes of anxiety experienced by clients, mammographers can provide an informed, empathetic approach to the mammographic process. By acknowledging factors which increase their own anxiety mammographers can reduce the impact of this on themselves and on their clients. Copyright (2003) Australian Institute of Radiography

  9. Breast cancer screening: the underuse of mammography

    International Nuclear Information System (INIS)

    Fox, S.; Baum, J.K.; Klos, D.S.; Tsou, C.V.

    1985-01-01

    The early detection of breast cancer is promoted by the American Cancer Society (ACS) and the American College of Radiology (ACR) by encouraging the regular use of three types of screening: breast self-examination (BSE), the clinical breast examination, and mammography. In August 1983, the ACS publicized seven recommendations pertaining to screening, including a revised statement about the routine use of mammography for women between the ages of 40 and 49 years. In response to the ACS statement, the present study assessed compliance with the updated recommendations for all three types of screening. The results show reasonable rates of compliance for the BSE (53%-69%) and clinical examination (70%-78%). In contrast, only 19% of the women between the ages of 35 and 49 and 25% of the women older than 50 reported complying with the recommendation to undergo one baseline screening mammogram. Some implications for health education by physicians and the professional education of physicians in the use of mammography are discussed

  10. Automated daily quality control analysis for mammography in a multi-unit imaging center.

    Science.gov (United States)

    Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli

    2018-01-01

    Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

  11. Factors influencing bladder stone formation in patients with spinal cord injury.

    Science.gov (United States)

    Favazza, Terry; Midha, Meena; Martin, Jessicca; Grob, B Mayer

    2004-01-01

    Bladder stones that form in patients with spinal cord injury (SCI) can cause significant morbidity. This study sought to analyze factors associated with bladder stone formation to determine which patients might be at increased risk to develop bladder stones. A review of 56 SCI patients treated for bladder calculi over a 10-year period at a single institution was performed. These patients were compared with a control population of general SCI patients known to be stone free. The factors compared were patient age, duration of injury, level of injury, completeness of injury, method of bladder management, and the presence of documented urinary tract infections with urease-producing organisms. All patients with stones were male and had a median age of 58.5 years. The median level of injury was C6, the median time since injury was 21 years, 66% had complete injuries, 68% managed their bladders with indwelling catheters or suprapubic tubes, and 83% had a history of infections with urease-producing organisms. When compared with the control group, patients forming bladder stones were older (P = 0.03), were more likely to have indwelling catheters (P < 0.0001), had a history of infections with urease-producing organisms (P = 0.04), and had complete injuries (P = 0.018). This information can be used to identify patients who have an increased risk of bladder stones and measures can be taken to reduce their incidence and morbidity.

  12. Humidity sorption on natural building stone

    Science.gov (United States)

    Franzen, C.; Mirwald, P.

    2003-04-01

    processes, physical, chemical or biological, depend on the presence of water. Like most porous materials building stone respond on humidity by water uptake. The sorption isotherm represents the equilibrium moisture, specific for each material. The determination of the isotherm for stone of low and small porosity like marble is difficult. With the help of a newly developed water sorption analysis chamber [2], which allows the simultaneous measurement of 11 samples, good results on stone/rock samples have been obtained. Even at marble species with pore volumes lower than 0.4 % isotherms are measured. This analytical method offers new insights in the pore behaviour of low porosity materials. The advantages of this technique which supplements other techniques (e.g. BET, Hg-porosimetry) are: i) the testing agent is identical to the weathering agent, water; ii) the atmospheric parameters at the measurement reflect the natural conditions - thus no changes to the material properties have to be considered; iii) due to the small diameter of the water molecule (~0.28 nm), smaller pores are reached than e.g. with N2 (~0.31 nm). Sorption isotherms of sandstone (Baumberg, Obernkirchen, Groeden), granite (Brixen), and marble (Sterzing, Laas) are presented. Particular as to marbles the resolution is considerably higher. A previously observed negative hysteresis [3] seems an effect due to limited data resolution. [1] Snethlage, R. (1984) Steinkonservierung, Bayer. LA Denkmalpflege, Ah. 22, 203 S. [2] Griesser, U.J., Dillenz, J. (2002) Neuartiges, vollautomatisches Feuchtesorptionsprüfgerät mit hohem Probendurchsatz, Feuchtetag 2002, Weimar, 85-93. [3] Fimmel, R. (1996) Verwitterungsverhalten der alpinen Marmore von Laas und Sterzing, Diss. Univ. Ibk, 116 S.

  13. Evaluation of potential crushed-salt constitutive models

    International Nuclear Information System (INIS)

    Callahan, G.D.; Loken, M.C.; Sambeek, L.L. Van; Chen, R.; Pfeifle, T.W.; Nieland, J.D.; Hansen, F.D.

    1995-12-01

    Constitutive models describing the deformation of crushed salt are presented in this report. Ten constitutive models with potential to describe the phenomenological and micromechanical processes for crushed salt were selected from a literature search. Three of these ten constitutive models, termed Sjaardema-Krieg, Zeuch, and Spiers models, were adopted as candidate constitutive models. The candidate constitutive models were generalized in a consistent manner to three-dimensional states of stress and modified to include the effects of temperature, grain size, and moisture content. A database including hydrostatic consolidation and shear consolidation tests conducted on Waste Isolation Pilot Plant and southeastern New Mexico salt was used to determine material parameters for the candidate constitutive models. Nonlinear least-squares model fitting to data from the hydrostatic consolidation tests, the shear consolidation tests, and a combination of the shear and hydrostatic tests produces three sets of material parameter values for the candidate models. The change in material parameter values from test group to test group indicates the empirical nature of the models. To evaluate the predictive capability of the candidate models, each parameter value set was used to predict each of the tests in the database. Based on the fitting statistics and the ability of the models to predict the test data, the Spiers model appeared to perform slightly better than the other two candidate models. The work reported here is a first-of-its kind evaluation of constitutive models for reconsolidation of crushed salt. Questions remain to be answered. Deficiencies in models and databases are identified and recommendations for future work are made. 85 refs

  14. Local recurrences after conservative surgery and irradiation for breast cancer: Diagnosis with mammography and ultrasound. Mammographie und Sonographie in der Rezidivdiagnostik nach brusterhaltender Therapie des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Hamberger, L; Schoen, G [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Steixner, G; Fritsch, E [Innsbruck Univ. (Austria). Universitaetsklinik fuer Strahlentherapie

    1991-06-01

    89 patients, who underwent conservative surgery for breast cancer were followed up with mammography and real-time sonography. 78 patients underwent postoperative irradiation. Depending on the time interval between irradiation and examination various alterations in mammographic and sonographic patterns were evident. Of 14 biospy-confirmed local recurrences, 11 were diagnosed by mammography and 12 by sonography. Combined use of mammography and sonography should therefore lead to better results in the diagnosis of local recurrences and to a reduction of unnecessary biopsies. (orig./GDG).

  15. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  16. Thermal volume changes in clays and clay-stones

    International Nuclear Information System (INIS)

    Delage, P.; Sulem, J.; Mohajerani, M.; Tang, A.M.; Monfared, M.

    2012-01-01

    Document available in extended abstract form only. The disposal of high activity exothermic radioactive waste at great depth in clay host rocks will induce a temperature elevation that has been investigated in various underground research laboratories in Belgium, France and Switzerland through in-situ tests. Thermal effects are better known in clays (in particular Boom clay) than in clay-stone (e.g. Opalinus clay and Callovo-Oxfordian clay-stone). In terms of volume changes, Figure 1 confirms the findings of Hueckel and Baldi (1990) that volume changes depend on the over-consolidation ratio (OCR) of the clay. In drained conditions, normally consolidated clays exhibit plastic contraction when heated, whereas over-consolidated clay exhibit elastic dilation. The nature of thermal volume changes in heated clays obviously has a significant effect on thermally induced pore pressures, when drainage is not instantaneous like what occurs in-situ. Compared to clays, the thermal volume change behaviour of clay-stones is less well known than that of clays. clay-stone are a priori suspected to behave like over-consolidated clays. In this paper, a comparison of recent results obtained in the laboratory on the drained thermal volume changes of clay-stones is presented and discussed. It is difficult to run drained mechanical tests in clay-stones like the Opalinus clay and the Callovo-Oxfordian clay-stone because of their quite low permeability (10 -12 - 10 -13 m/s). This also holds true for thermal tests. Due to the significant difference in thermal expansion coefficient between minerals and water, it is necessary to adopt very slow heating rate (0.5 - 1 C/h) to avoid any thermal pressurization. To do so, a new hollow cylinder apparatus (100 mm external diameter, 60 mm internal diameter) with lateral drainages reducing the drainage length to half the sample thickness (10 mm) has been developed (Monfared et al. 2011). The results of a drained cyclic thermal test carried out on

  17. Image quality and radiation exposure in digital storage plate mammography with magnification technique

    International Nuclear Information System (INIS)

    Fiedler, E.; Aichinger, U.; Boehner, C.; Schulz-Wendtland, R.; Bautz, W.; Saebel, M.

    1999-01-01

    Purpose: Comparison of image quality between digital phosphor storage plate mammography in magnification technique and a conventional film screen system regarding the special aspect of radiation exposure. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system and two digital storage plate systems. Additionally, the radiograms of one digital system were postprocessed emphasizing contrast and included in the comparison. Results: The detectability of details in storage plate mammographies with magnification technique is almost equal to that of film screen mammographies. Thereby, lower radiation exposures were necessary using the digital systems. Conclusions: Based on these results, storage plate mammography in magnification technique is used in clinical routine at our institution. The correct parameters in image postprocessing are of elementary importance for detail detectability. Future studies must show, whether the lower radiation exposure in digital radiograms of the breast, revealing much higher background noise, will allow the same detail detectability as film screen mammographies. (orig.) [de

  18. Compositions of stone and stone surface materials of historical monuments from Vidzeme and Zemgale

    International Nuclear Information System (INIS)

    Actins, A.; Spricis, A.; Zekunde, A.; Nemerova, A.

    2004-01-01

    By means of x-ray analysis composition of stone and stone surface materials of historical monuments from Vidzeme and Zemgale was investigated. Corrosion products of tuffa materials were identified on surfaces of some investigated monuments. Similarity of composition of products of stone corrosion for monuments from Latvia and Poland was recognised. Content of heavy metals at stone materials of historical monuments and at the surface layers of these monuments was investigated by means of atomic absorption and potentiometric stripping methods. Reasons of formation of compounds and pollution of investigated samples were discussed. (full text)

  19. Ultrasound as an Adjunct to Mammography for Breast Cancer Screening: A Health Technology Assessment

    Science.gov (United States)

    Nikitovic-Jokic, Milica; Tu, Hong Anh; Palimaka, Stefan; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Ultrasound has been suggested as a safe adjunct screening tool that can detect breast cancers missed on mammography. We investigated the benefits, harms, cost-effectiveness, and cost burden of ultrasound as an adjunct to mammography compared with mammography alone for screening women at average risk and at high risk for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, EBM Reviews, and the NHS Economic Evaluation Database, from January 1998 to June 2015, for evidence of effectiveness, harms, diagnostic accuracy, and cost-effectiveness. Only studies evaluating the use of ultrasound as an adjunct to mammography in the specified populations were included. We also conducted a cost analysis to estimate the costs in Ontario over the next 5 years to fund ultrasound as an adjunct to mammography in breast cancer screening for high-risk women who are contraindicated for MRI, the current standard of care to supplement mammography. Results No studies in average-risk women met the inclusion criteria of the clinical review. We included 5 prospective, paired cohort studies in high-risk women, 4 of which were relevant to the Ontario context. Adjunct ultrasound identified between 2.3 and 5.9 additional breast cancers per 1,000 screens. The average pooled sensitivity of mammography and ultrasound was 53%, a statistically significant increase relative to mammography alone (absolute increase 13%; P screening alone. The GRADE for this body of evidence was low. Additional annual costs of using breast ultrasound as an adjunct to mammography for high-risk women in Ontario contraindicated for MRI would range from $15,500 to $30,250 in the next 5 years. Conclusions We found no evidence that evaluated the comparative effectiveness or diagnostic accuracy of screening breast ultrasound as an adjunct to

  20. [Mammography screening of breast cancer in Tunisia. Results of first experience].

    Science.gov (United States)

    Kribi, Lilia; Sellami, Dorra; el Amri, Aïda; Mnif, Nejla; Ellouze, Thouraya; Chebbi, Ali; Ben Romdhane, Khaled; Hamza, Radhi

    2003-01-01

    This article reports the results of a mammography screening program of breast cancer, realized in the department of Radiology, Charles Nicolle hospital. A free screening mammography with two incidences was offered to women aged from 40 to 70 years old. 2200 mammographies were realized from May 1995 till July 1997. Women having a positive test benefited of a diagnostic explorations in the same unity. The positive test rate was 24%. Predictive positive value was 31%. This program allowed to detect 10 subclinical cancers, corresponding to a rate of detection of 4.5 cancers for 1000 women. This program is a first experience which demonstrated the feasibility of the mammography screening to wide scale and allowed the medical and paramedical team to acquire an experience.

  1. Benefits, risks, and costs of mammography

    International Nuclear Information System (INIS)

    Richter, B.; Rausch, L.

    1977-01-01

    The risk seems to be acceptable if the age-dependency of the frequency of breast cancer is disregarded, i.e. if calculation is done with average values, as is being done frequently (15, 25, 32, 48). This procedure however veils the real circumstances in the examination of young women thus also veiling a risk which could otherwise be made precise and avoidable. The risk of radiation-induced cancerogenesis in the female breast was verified by similar statements made by several empiric investigations on man. The course of the dose-effect-relation in the region of few rad is still unexplained however, although the results do not contradict to the assumption of a linear dose-effect-relation. Thus it seems not advisable to ignore the induction of carcinomas by x-radiation for the sphere of mammography with the doses usually applied today. A reduction of radiation exposition by dose-saving measures to one tenth of the present value (or less) however would make the risk highly unimportant. Advantage/risk/cost-analyses should encourage the responsible persons to make reasonable proposals for the application of methods, in this case mammography. The discouraging of patients whom mammography is indicated for would be a side-effect which is not desired. Just as wrong would be the stimulation of an unjustified feeling of being sure and the demand for costly medical measures by uncritical reports of success. The indication of the considerably high costs of mammography should, together with the advantage expected, be a quantitative criterion for the optimal distribution of limited means the necessity of which cannot be denied. (orig.) [de

  2. Factors influencing elderly women's mammography screening decisions: implications for counseling

    Directory of Open Access Journals (Sweden)

    Davis Roger B

    2007-11-01

    Full Text Available Abstract Background Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65–79. Methods Telephone surveys of 107 women aged 80+ and 93 women aged 65–79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate. The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Results Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3% had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65–79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65–79. Conclusion While a doctor's recommendation is the most important factor influencing

  3. Introduction of computed radiography in two mammography services: image quality and dose analysis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela R.; Gamba, Humberto R.; Ramos, Maria M.; Faversani, Gislene G.; Peixoto, Joao E.

    2008-01-01

    This study has evaluated the impact of the introduction of CR technology in the routine of two mammography services operating with Lorad Affinity X-ray units and CR Fuji Profect One system. Mean glandular dose was determined to set Automatic Exposure Control parameters according to optimal image quality. Reject analysis of patient images was made to establish the overall impact in routine work. As regards to dose evaluation, the results show that in 44% of mammography exams the MGD were above action levels. It is due to inadequate AEC adjustment and insufficient training of the staff in operating CR systems. In addition, common errors with screen/film systems like wrong breast positing and selection of exposure parameters, as well as X-ray unit failures like insufficient anti scatter grid movement still occurs. This is an indication that ongoing efforts should be concentrated in the constancy of AEC adjustment for CR image plates and staff training. Until now, brazilian health authorities did not implement any program to evaluate digital systems performance, but efforts are being done in order to provide guidelines to breast screening aiming the control of breast dose compatible with optimal image quality. (author)

  4. Study of signal-to-noise ratio in digital mammography

    Science.gov (United States)

    Kato, Yuri; Fujita, Naotoshi; Kodera, Yoshie

    2009-02-01

    Mammography techniques have recently advanced from those using analog systems (the screen-film system) to those using digital systems; for example, computed radiography (CR) and flat-panel detectors (FPDs) are nowadays used in mammography. Further, phase contrast mammography (PCM)-a digital technique by which images with a magnification of 1.75× can be obtained-is now available in the market. We studied the effect of the air gap in PCM and evaluated the effectiveness of an antiscatter x-ray grid in conventional mammography (CM) by measuring the scatter fraction ratio (SFR) and relative signal-to-noise ratio (rSNR) and comparing them between PCM and the digital CM. The results indicated that the SFRs for the CM images obtained with a grid were the lowest and that these ratios were almost the same as those for the PCM images. In contrast, the rSNRs for the PCM images were the highest, which means that the scattering of x-rays was sufficiently reduced by the air gap without the loss of primary x-rays.

  5. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  6. Physical image quality of computed radiography in mammography system

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Isa; Wan Muhamad Saridan Wan Hassan; Fatimah Othman

    2013-01-01

    Full-text: Mammography is a screening procedure that mostly used for early detection of breast cancer. In digital imaging system, Computed Radiography is a cost-effective technology that applied indirect conversion detector. The paper presents physical image quality parameter measurements namely modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of Computed Radiography in mammography system. MTF was calculated from two different orientations of slanted images of an edge test device and NNPS was estimated using flat-field image. Both images were acquired using a standard mammography beam quality. DQE was determined by applying the MTF and NNPS values into our developed software program. Both orientations have similar DQE characteristics. (author)

  7. Histopathology Predicts the Mechanism of Stone Formation

    Science.gov (United States)

    Evan, Andrew P.

    2007-04-01

    About 5% of American women and 12% of men will develop a kidney stone at some time in their life and these numbers appear to be on the rise. Despite years of scientific research into the mechanisms of stone formation and growth, limited advances have been made until recently. Randall's original observations and thoughts on the mechanisms for kidney stone formation have been validated for idiopathic calcium oxalate stone formers (ICSF) but not for most other stone forming groups. Our current studies on selected groups of human stone formers using intraoperative papillary biopsies has shown overwhelming evidence for the presence of Randall's plaque in ICSF and that stone formation and growth are exclusively linked to its availability to urinary ions and proteins. Intense investigation of the plaque-stone junction is needed if we are to understand the factors leading to the overgrowth process on exposed regions of plaque. Such information should allow the development of treatment strategies to block stone formation in ICSF patients. Patients who form brushite stones, or who form apatite stones because of distal renal tubular acidosis (dRTA), or patients with calcium oxalate stones due to obesity bypass procedures, or patients with cystinuria, get plugged inner medullary collecting ducts (IMCD) which leads to total destruction of the lining cells and focal sites of interstitial fibrosis. These stone formers have plaque but at levels equal to or below non-stone formers, which would suggest that they form stones by a different mechanism than do ICSF patients.

  8. Obesometric factors associated with increased skin-to-stone distances in renal stone patients.

    Science.gov (United States)

    Allard, Christopher B; Shuster, Anatoly; Pinthus, Jehonathan H; Farrokhyar, Forough; Raees, A; Patlas, Michael; Matsumoto, Edward D; Whelan, J Paul

    2012-12-01

    Obese patients are at increased risk for renal stones as well as treatment failures due to increased skin-to-stone distances (SSD) and harder stone compositions. We investigated the relationships between obesometric parameters (body mass index [BMI], body fat distribution and obesity-related hormone levels) with SSD and stone hardness. We prospectively enrolled patients undergoing stone interventions at our institution. Computed tomography (CT) scans were analyzed; adipose tissue was identified according to Hounsfield units (HU) and separated into subcutaneous (SAT) and visceral (VAT) components. The pixels were averaged at three levels to calculate fat distribution: %VAT = (VAT)/(VAT + SAT). SSD was measured and HU were used as a surrogate for stone hardness. Obesity-related hormones leptin and adiponectin were measured by ELISA. Seventy-nine patients were prospectively enrolled. Mean BMI and %VAT were 30.02 kg/m2 and 40.13 kg/m2. Mean leptin and adiponectin levels were 17.5 ng/mL and 7.67 mcg/mL indicating high risk for metabolic consequences of obesity. Females had greater proportions of subcutaneous fat than males (%VAT 28.4 versus 46.94, p r = 0.454, p = 0.008). Obese patients with %VAT > 40 versus stone compositions as measured by HU than non-diabetics (982.86 versus 648.86, p = 0.001). Obesometric parameters such as BMI, body fat distribution, and the presence of diabetes mellitus are important considerations in the management of renal stone disease. A large proportion of subcutaneous fat, which can be estimated by physical examination, predicts SSD among obese patients and may aid treatment decisions in patients, particularly those without pre-treatment CT scans. Further studies are needed to refine the role of obesometrics in personalizing treatment decisions.

  9. Analysis of the engine fragment threat and the crush environment for small packages carried on U.S. commercial jet aircraft

    International Nuclear Information System (INIS)

    Hartman, W.F.; McClure, J.D.; von Riesemann, W.A.

    1978-01-01

    The results of two separate analyses are reported. The engine fragment analysis determined the probability of a small package being in the path of a fragment from a failure in a gas turbine engine. The calculated values show that, depending on aircraft type, the incidence rate varies by approximately an order of magnitude from a high of about once per 5 million flights to a low of nearly once every 40 million package flights for a flight of five hours' duration. The analysis of the crush environment consisted of an examination of two principal crush modes, i.e., vertical and longitudinal crush. The vertical crush mode was examined by formulating a structural model of the cargo deck beams of the aircraft. The longitudinal crush mode was studied by using dynamic models of the aircraft cargo and the radioactive material package (RAM). The results of the analysis of these crush modes provided the basis for the formulation of a 310 kN/(70,000 lb) crush test to simulate vertical crush. The longitudinal crush analysis indicated that it was possible, under infrequently occurring conditions, to produce extremely large crush forces and hence it was recommended that RAM packages be located in the aft end of aircraft cargo compartments to minimize the effects of longitudinal crush

  10. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  11. Analysis of a hypothetical dropped spent nuclear fuel shipping cask impacting a floor mounted crush pad

    International Nuclear Information System (INIS)

    Hawkes, B.D.; Uldrich, E.D.

    1998-03-01

    A crush pad has been designed and analyzed to absorb the kinetic energy of a hypothetically dropped spent nuclear fuel shipping cask into a 44-ft. deep cask unloading pool at the Idaho Chemical Processing Plant. The 110-ton Large Cell Cask was assumed to be accidentally dropped onto the parapet of the unloading pool, causing the cask to tumble through the pool water and impact the floor mounted crush pad with the cask's top corner. The crush pad contains rigid polyurethane foam, which was modeled in a separate computer analysis to simulate the manufacturer's testing of the foam and to determine the foam's stress and strain characteristics. This computer analysis verified that the foam was accurately represented in the analysis to follow. A detailed non-linear, dynamic finite element analysis was then performed on the crush pad and adjacent pool structure to assure that a drop of this massive cask does not result in unacceptable damage to the storage facility. Additionally, verification was made that the crush pad adequately protects the cask from severe impact loading. At impact, the cask has significant vertical, horizontal and rotational velocities. The crush pad absorbs much of the energy of the cask through plastic deformation during primary and secondary impacts. After the primary impact with the crush pad, the cask still has sufficient energy to rebound and rotate until it impacts the pool wall. An assessment is made of the damage to the crush pad and pool wall and of the impact loading on the cask

  12. A benchmark study of procedures for analysis of axial crushing of bulbous bows

    DEFF Research Database (Denmark)

    Yamada, Yasuhira; Pedersen, Preben Terndrup

    2008-01-01

    Simplified methods to estimate mean axial crushing forces of plated structures are reviewed and applied to a series of experimental results for axial crushing of large-scale bulbous bow models. Methods based on intersection unit elements such as L-, T- and X-type elements as well as methods based...

  13. Digital mammography and their developments; Digitale Mammografie und ihre Weiterentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne [Universitaetsmedizin Goettingen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Fischer, Uwe [Diagnostisches Brustzentrum Goettingen (Germany)

    2015-09-15

    At the present time digital mammography is a satisfactory breast diagnostic imaging in clinical as well as screening mammography in defined age groups. Nevertheless it shows beside the application of ionizing radiation in women with dense breasts limitations in the detection of non calcification breast cancers. Tomosynthesis, digital contrast-enhanced mammography and breast-CT with or without contrast media lead to better results. Especially the application of contrast media for the visualisation of the tumor angiogenesis is invariably superior to all other non-contrast imaging modalities. However, the excellent results of breast MRI will be probably accessible with none of the new procedures.

  14. Digital breast tomosynthesis versus digital mammography: a clinical performance study

    International Nuclear Information System (INIS)

    Gennaro, Gisella; Baldan, Enrica; Bezzon, Elisabetta; Polico, Ilaria; Proietti, Alessandro; Toffoli, Aida; Toledano, Alicia; Di Maggio, Cosimo; La Grassa, Manuela; Pescarini, Luigi; Muzzio, Pier Carlo

    2010-01-01

    To compare the clinical performance of digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) in a diagnostic population. The study enrolled 200 consenting women who had at least one breast lesion discovered by mammography and/or ultrasound classified as doubtful or suspicious or probably malignant. They underwent tomosynthesis in one view [mediolateral oblique (MLO)] of both breasts at a dose comparable to that of standard screen-film mammography in two views [craniocaudal (CC) and MLO]. Images were rated by six breast radiologists using the BIRADS score. Ratings were compared with the truth established according to the standard of care and a multiple-reader multiple-case (MRMC) receiver-operating characteristic (ROC) analysis was performed. Clinical performance of DBT compared with that of FFDM was evaluated in terms of the difference between areas under ROC curves (AUCs) for BIRADS scores. Overall clinical performance with DBT and FFDM for malignant versus all other cases was not significantly different (AUCs 0.851 vs 0.836, p = 0.645). The lower limit of the 95% CI or the difference between DBT and FFDM AUCs was -4.9%. Clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views. (orig.)

  15. SYNTHESIS OF EXPANDER TO PREVENT CONTRACTION OF CEMENT STONE

    Directory of Open Access Journals (Sweden)

    Elenova Aurika Almazovna

    2017-03-01

    Full Text Available This article contains the results of studies of the use of additives containing crystallization components significantly affecting the curing of cement, improving the structure of cement stone and concrete. The crystalline component is obtained using the rotary-pulse unit, which provides not only the grinding of agents, but their interaction with each other as well in order to accelerate the hydration and structure formation in cement stone. The degree, and kinetics of hydration, the composition of hydrated phases, the structure of the additives and cement stone was studied using the following methods: x-ray diffraction (XRD, differential thermal analysis (DTA, scanning electron microscope (SEM. Mechanical properties of cement were determined by standard methods and techniques. The expander produced by means of hydrodynamic activation of the sulfoaluminate clinker (SAC consists of ettringite and hydrated calcium silicates, which are characterized by high dispersion rate (less than 10 µm and reactivity as the seed for the crystallization of hydrated compounds. The introduction of the ultrafine additives of the crystalline SAC (within 1-5% was discovered to cause expansion of the cement stone. Implementation of the additives increases cement hydration and contributes to the formation of active centers of crystallization that lead to the fast formation of ettringite, hydrated calcium aluminates and calcium silicates. The activated crystalline additive provides for significant reduction of porosity, initial curing, and high strength of cement stone. In addition, the additive is an expansive component, forming needle-like crystals of ettringite during hydration. These microcrystals grow in the capillaries of cement stone, filling them, and create conditions for improving the crack resistance of cement concrete.

  16. Mammography in breast screening and in the evaluation and management of breast cancer

    International Nuclear Information System (INIS)

    Onyesoh, C.N.

    2006-01-01

    This paper aims to discuss the importance of breast screening most especially amongst women above the age of 40 years.the limitation of the screening procedure is due to lack of special machines and power awareness campaigns. the application of Mammography and ultrasound in the examination of the breast and other breast imaging techniques will be considered in this paper. The paper will look at the indications for mammography, indications for breast ultrasound, signs of breast carcinoma on mammography, breast enlargement and also the need for breast ultrasound in cases of discrete Mammography

  17. Mammography screening: A major issue in medicine.

    Science.gov (United States)

    Autier, Philippe; Boniol, Mathieu

    2018-02-01

    Breast cancer mortality is declining in most high-income countries. The role of mammography screening in these declines is much debated. Screening impacts cancer mortality through decreasing the incidence of number of advanced cancers with poor prognosis, while therapies and patient management impact cancer mortality through decreasing the fatality of cancers. The effectiveness of cancer screening is the ability of a screening method to curb the incidence of advanced cancers in populations. Methods for evaluating cancer screening effectiveness are based on the monitoring of age-adjusted incidence rates of advanced cancers that should decrease after the introduction of screening. Likewise, cancer-specific mortality rates should decline more rapidly in areas with screening than in areas without or with lower levels of screening but where patient management is similar. These two criteria have provided evidence that screening for colorectal and cervical cancer contributes to decreasing the mortality associated with these two cancers. In contrast, screening for neuroblastoma in children was discontinued in the early 2000s because these two criteria were not met. In addition, overdiagnosis - i.e. the detection of non-progressing occult neuroblastoma that would not have been life-threatening during the subject's lifetime - is a major undesirable consequence of screening. Accumulating epidemiological data show that in populations where mammography screening has been widespread for a long time, there has been no or only a modest decline in the incidence of advanced cancers, including that of de novo metastatic (stage IV) cancers at diagnosis. Moreover, breast cancer mortality reductions are similar in areas with early introduction and high penetration of screening and in areas with late introduction and low penetration of screening. Overdiagnosis is commonplace, representing 20% or more of all breast cancers among women invited to screening and 30-50% of screen

  18. Can stone density on plain radiography predict the outcome of extracorporeal shockwave lithotripsy for ureteral stones?

    Science.gov (United States)

    Lim, Ki Hong; Jung, Jin-Hee; Kwon, Jae Hyun; Lee, Yong Seok; Bae, Jungbum; Cho, Min Chul; Lee, Kwang Soo

    2015-01-01

    Purpose The objective was to determine whether stone density on plain radiography (kidney-ureter-bladder, KUB) could predict the outcome of extracorporeal shockwave lithotripsy (ESWL) for ureteral stones. Materials and Methods A total of 223 patients treated by ESWL for radio-opaque ureteral stones of 5 to 20 mm were included in this retrospective study. All patients underwent routine blood and urine analyses, plain radiography (KUB), and noncontrast computed tomography (NCCT) before ESWL. Demographic, stone, and radiological characteristics on KUB and NCCT were analyzed. The patients were categorized into two groups: lower-density (LD) group (radiodensity less than or equal to that of the 12th rib, n=163) and higher-density (HD) group (radiodensity greater than that of the 12th rib, n=60). Stone-free status was assessed by KUB every week after ESWL. A successful outcome was defined as stone free within 1 month after ESWL. Results Mean stone size in the LD group was significantly smaller than that in the HD group (7.5±1.4 mm compared with 9.9±2.9 mm, p=0.002). The overall success rates in the LD and HD groups were 82.1% and 60.0%, respectively (p=0.007). The mean duration of stone-free status and average number of SWL sessions required for success in the two groups were 21.7 compared with 39.2 days and 1.8 compared with 2.3, respectively (pESWL since colic and radiodensity of the stone on KUB were independent predictors of successful ESWL. Conclusions Our data suggest that larger stone size, longer time to ESWL, and ureteral stones with a radiodensity greater than that of the 12th rib may be at a relatively higher risk of ESWL failure 1 month after the procedure. PMID:25598937

  19. Adaptation of oral medication in people institutionalized in nursing homes for whom medication is crushed: The ADECUA Study

    Directory of Open Access Journals (Sweden)

    Francisco Apolo Carvajal

    2016-12-01

    Full Text Available Purpose: To evaluate the effect of pharmacist interventions in the adaptation of pharmaceutical forms in elders institutionalized in nursing homes whose medicines are crushed, which may have a clinical relevance. Methods: Quasi-experimental, multicenter, transversal and prospective study carried out in 10 nursing homes. Subjects for whom drugs were being crushed were identified. Their treatments were reviewed in order to identify drugs that should not be crushed. In these cases, we proposed an alternative to the physician and we evaluated the degree of acceptance, its association to other variables and the pre-post adaptation index (tablets that can be crushed and capsules that can be opened/ total number of tablets and capsules before and after the intervention. Moreover, health professionals received a training course. Results: Medication was being crushed for 33% (618/1875 of residents (mean: 5 drugs susceptible of crushing. 220 pharmaceutical interventions were performed, mostly in extended release or gastro-resistant drugs (48% were accepted. Switch was the type of intervention more frequent (79%, mainly to Purpose: To evaluate the effect of pharmacist interventions in the adaptation of pharmaceutical forms in elders institutionalized in nursing homes whose medicines are crushed, which may have a clinical relevance. Methods: Quasi-experimental, multicenter, transversal and prospective study carried out in 10 nursing homes. Subjects for whom drugs were being crushed were identified. Their treatments were reviewed in order to identify drugs that should not be crushed. In these cases, we proposed an alternative to the physician and we evaluated the degree of acceptance, its association to other variables and the pre-post adaptation index (tablets that can be crushed and capsules that can be opened/ total number of tablets and capsules before and after the intervention. Moreover, health professionals received a training course. Results

  20. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  1. Trends in urological stone disease.

    Science.gov (United States)

    Turney, Benjamin W; Reynard, John M; Noble, Jeremy G; Keoghane, Stephen R

    2012-04-01

    To summarize the changes in prevalence and treatment of upper urinary tract stone disease in the UK over the last 10 years. Data from the Hospital Episode Statistics (HES) website (http://www.hesonline.nhs.uk) were extracted, summarized and presented. The number of upper urinary tract stone hospital episodes increased by 63% to 83,050 in the 10-year period. The use of shock wave lithotripsy (SWL) for treating all upper tract stones increased from 14,491 cases in 2000-2001 to 22,402 cases in 2010 (a 55% increase) with a 69% increase in lithotripsy for renal stones. There was a 127% increase in the number of ureteroscopic stone treatments from 6,283 to 14,242 cases over the 10-year period with a 49% increase from 2007/2008 to 2009/2010. There was a decline in open surgery for upper tract stones from 278 cases in 2000/2001 to 47 cases in 2009/2010 (an 83% reduction). Treatment for stone disease has increased substantially in comparison with other urological activity. In 2009/2010, SWL was performed almost as frequently as transurethral resection of the prostate or transurethral resection of bladder tumour, ureteroscopy for stones was performed more frequently than nephrectomy, radical prostatectomy and cystectomy combined, and percutaneous nephrolithotomy was performed more frequently than cystectomy. The present study highlights the increase in prevalence and treatment of stone disease in the UK over the last 10 years. If this trend continues it has important implications for workforce planning, training, service delivery and research in the field of urolithiasis. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  2. Effect of crushing temperature on virgin olive oil quality and composition

    OpenAIRE

    Ö. Kula; A. Yıldırım; A. Yorulmaz; M. Duran; İ. Mutlu; M. Kıvrak

    2018-01-01

    The objective of the current study was to assess the influence of a modified crushing process and kneading operation on the quality parameters, volatile compounds, and the fatty acid and sterol profiles of virgin olive oil from the Edremit yaglik variety. In the study, olive oil samples were produced in two different processes. The first one was produced without malaxation and the second one was produced with the malaxing process. During crushing, the effect of different temperatures was test...

  3. XERG-mammography system: a solution to the dose-quality problem

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, M

    1981-05-01

    The XERG (Xonics-Electron-Radio-Graphy) system is the first ionographic system (High-Pressure-Gas-Iono-graphy) suitable for clinical application which became available for testing. The basic principle, the function and imaging qualities of the XERG system are described and first clinical experiences reported. The XERG mammogram is a transparent X-ray negative image, the image quality of which is characterized by good general image contrast, a moderate edge-effect and a high quantum-noise level but giving an extremely low dose rate (4.5% compared to screenless mammography film). Although the XERG quality is not satisfactory in contact technique, it yields results which are equal in quality, when using a 1.5-fold magnification technique, to the results obtained with screenless film mammography at one-tenth of the dose, and is superior to any commercially available film-screen system. Hence, in our opinion, the XERG mammography system is a step forward towards high-quality low-dose mammography.

  4. [Hierarchy structuring for mammography technique by interpretive structural modeling method].

    Science.gov (United States)

    Kudo, Nozomi; Kurowarabi, Kunio; Terashita, Takayoshi; Nishimoto, Naoki; Ogasawara, Katsuhiko

    2009-10-20

    Participation in screening mammography is currently desired in Japan because of the increase in breast cancer morbidity. However, the pain and discomfort of mammography is recognized as a significant deterrent for women considering this examination. Thus quick procedures, sufficient experience, and advanced skills are required for radiologic technologists. The aim of this study was to make the point of imaging techniques explicit and to help understand the complicated procedure. We interviewed 3 technologists who were highly skilled in mammography, and 14 factors were retrieved by using brainstorming and the KJ method. We then applied Interpretive Structural Modeling (ISM) to the factors and developed a hierarchical concept structure. The result showed a six-layer hierarchy whose top node was explanation of the entire procedure on mammography. Male technologists were related to as a negative factor. Factors concerned with explanation were at the upper node. We gave attention to X-ray techniques and considerations. The findings will help beginners improve their skills.

  5. Magnetic resonance imaging evaluation of acute crush injury of rabbit sciatic nerve: correlation with histology

    International Nuclear Information System (INIS)

    Li, X.; Shen, J.; Chen, J.; Wang, X.; Liu, Q.; Liang, B.

    2008-01-01

    To investigate the relation between the quantitative assessment of magnetic resonance imaging (MRI) features and the correlation with histology and functional recovery by using the rabbit sciatic nerve crush model. In New Zealand, 32 rabbits were randomly divided into 2 groups (group A and B); all rabbits underwent crushing injury of their left sciatic nerve. In group A (n = 16), the sciatic nerves were crushed by using microvessel clamps with a strength of 3.61 kg. In group B (n = 16), the sciatic nerves were crushed with a strength of 10.50 kg. Right sciatic nerves were served as controls. Serial MRI of both hind limbs in each rabbit was performed before and at the time point of 1, 2, 4, and 8 weeks after crushed injury. The MRI protocol included T1-weighted spin-echo (T1WI), 3 dimension turbo spin-echo T2-weighted (3DT2WI), T2-weighted turbo spin-echo images with spectral presaturation with inversion recovery (T2WI/SPIR), balanced fast-field echo (B-FFE) and short-time inversion recovery (STIR) sequences. The coronal image of the sciatic nerve was obtained. The nerve and muscle signal ratio (SIR) on each sequence was measured. The function recovery was observed and pathological examination was performed at each time point. A signal intensity increase of the distal segment of crushed sciatic nerves was found on 3DT2WI, T2WI/SP1R, B-FFE, and STIR, but not on T,WI images. Of 32 crushed nerves, 30 nerves showed high signal intensity. The correct diagnostic rate was 93.75% with false negative-positive of 6.25%. The SIR of the crushed sciatic nerve at distal portion was higher than those of the control nerves; there was a statistically significant difference (P 0.05). The SIR between group A and group B was not found statistically significantly different (P > 0.05). The SIR of crushed nerves at distal portion increased at one week after the crush injury, subsequently further increased, and reached a maximum at 2 weeks. The pathological examination revealed myelin

  6. Fasting and Urinary Stones

    Directory of Open Access Journals (Sweden)

    Ali Shamsa

    2013-11-01

    Full Text Available Introduction: Fasting is considered as one of the most important practices of Islam, and according to Prophet Mohammad, fasting is obligatory upon Muslims. The aim of this study is to evaluate the effects of fasting on urinary stones. Materials and Methods: Very few studies have been carried out on urinary stones and the effect of Ramadan fasting. The sources of the present study are Medline and articles presented by local and Muslim researchers. Meanwhile, since we are acquainted with three well-known researchers in the field of urology, we contacted them via email and asked for their professional opinions. Results: The results of studies about the relationship of urinary stones and their incidence in Ramadan are not alike, and are even sometimes contradictory. Some believe that increased incidence of urinary stones in Ramadan is related not to fasting, but to the rise of weather temperature in hot months, and an increase in humidity. Conclusion: Numerous biological and behavioral changes occur in people who fast in Ramadan and some researchers believe that urinary stone increases during this month.

  7. Carrara Marble: a nomination for Global Heritage Stone Resource

    Science.gov (United States)

    primavori, piero

    2014-05-01

    Bardiglio" (Bardiglio marble); 4) "Marmo Nuvolato" (Cloud-like marble); 5) "Marmo Arabescato" (Arabesque-like marble); 6) "Marmo Statuario"/"Statuario Venato" (Statuary marble/Veined statuary); 7) "Marmo Calacata" (Calacata marble). These seven main varieties can be subdivided into many other types due to slight chromatic variations which are often characteristics of a very restricted area, or just one quarry, or even one limited period of time. Apart from its intrinsic geological, petrographic, commercial and technical properties, several issues related to the Carrara Marble are considered to be of relevant importance for its designation as a Global Ornamental Stone", among which the Marble Museum, the Fine Arts Academy, the Artistic Marble Consortium, the Sculpture Museum, the historical commemoration of the "lizzatura" and the remnants of the marble railway stand out.

  8. The economics of stone disease.

    Science.gov (United States)

    Canvasser, Noah E; Alken, Peter; Lipkin, Michael; Nakada, Stephen Y; Sodha, Hiren S; Tepeler, Abdulkadir; Lotan, Yair

    2017-09-01

    The rising prevalence of kidney stone disease is associated with significant costs to healthcare systems worldwide. This is in part due to direct procedural and medical management costs, as well as indirect costs to health systems, patients, and families. A number of manuscripts evaulating the economics of stone disease have been published since the 2008s International Consultation on Stone Disease. These highlight costs associated with stone disease, including acute management, surgical management, and medical management. This work hopes to highlight optimization in care by reducing inefficient treatments and maximizing cost-efficient preventative strategies.

  9. Regional differences in constituents of gall stones.

    Science.gov (United States)

    Ashok, M; Nageshwar Reddy, D; Jayanthi, V; Kalkura, S N; Vijayan, V; Gokulakrishnan, S; Nair, K G M

    2005-01-01

    The pathogenesis of pigment and mixed gall stone formation remains elusive. The elemental constituents of gall stones from southern states of Tamil Nadu, Kerala and Karnataka have been characterized. Our aim was to determine the elemental concentration of representative samples of pigment, mixed and cholesterol gall stones from Andhra Pradesh using proton-induced X-ray emission (PIXE) using a 3 MV horizontal pelletron accelerator. Pigment gall stones had significantly high concentrations of copper, iron and lead; chromium was absent. Except for iron all these elements were significantly low in cholesterol gall stones and intermediate levels were seen in mixed gall stones. Highest concentrations of chromium was seen in cholesterol and titanium in mixed gall stones respectively; latter similar to other southern states. Arsenic was distinctly absent in cholesterol and mixed gall stones. The study has identified differences in elemental components of the gall stones from Andhra Pradesh.

  10. The bioreceptivity of building stone

    Science.gov (United States)

    Mauko Pranjić, Alenka; Mulec, Janez; Muck, Tadeja; Hladnik, Aleš; Mladenovič, Ana

    2015-04-01

    Bioreceptivity is an intrinsic property of stone, and is defined as the ability of a material to be colonized by living organisms. The fouling and staining of building stone material due to the activity of microorganisms presents a serious problem in modern as well as historical buildings, not only due to the aesthetic impact but also due to the deterioration of the material. Biological colonisation on stone materials is influenced by a number of factors, e.g. the intrinsic properties of the stone (porosity, roughness, permeability, mineral composition), environmental parameters (e.g. solar radiation, temperature, water regime, climate, etc.), and specific microclimatic parameters (e.g. orientation, exposure to shadow, permanent capillary humidity, etc.). In order to assess the bioreceptivity of building stones, use is often made of artificial colonisation experiments compromising the inoculation of stones with a single species or a few isolated strains under laboratory conditions. In the present work the authors present the development of a method for the determination of bioreceptivity, as well as a study of the bioreceptivity of selected natural stone versus the latter's intrinsic properties. Field examples of biodeterioration are also presented. The study was supported by the Slovenian Research Agency (L1-5453).

  11. Celecoxib accelerates functional recovery after sciatic nerve crush in the rat

    Directory of Open Access Journals (Sweden)

    Fernández-Garza Nancy E

    2008-11-01

    Full Text Available Abstract The inflammatory response appears to be essential in the modulation of the degeneration and regeneration process after peripheral nerve injury. In injured nerves, cyclooxygenase-2 (COX-2 is strongly upregulated around the injury site, possibly playing a role in the regulation of the inflammatory response. In this study we investigated the effect of celecoxib, a COX-2 inhibitor, on functional recovery after sciatic nerve crush in rats. Unilateral sciatic nerve crush injury was performed on 10 male Wistar rats. Animals on the experimental group (n = 5 received celecoxib (10 mg/kg ip immediately before the crush injury and daily for 7 days after the injury. Control group (n = 5 received normal saline at equal regimen. A sham group (n = 5, where sciatic nerve was exposed but not crushed, was also evaluated. Functional recovery was then assessed by calculating the sciatic functional index (SFI on days 0,1,7,14 and 21 in all groups, and registering the day of motor and walking onset. In comparison with control group, celecoxib treatment (experimental group had significant beneficial effects on SFI, with a significantly better score on day 7. Anti-inflammatory drug celecoxib should be considered in the treatment of peripheral nerve injuries, but further studies are needed to explain the mechanism of its neuroprotective effects.

  12. Mechanistic modeling for mammography screening risks

    International Nuclear Information System (INIS)

    Bijwaard, Harmen

    2008-01-01

    Full text: Western populations show a very high incidence of breast cancer and in many countries mammography screening programs have been set up for the early detection of these cancers. Through these programs large numbers of women (in the Netherlands, 700.000 per year) are exposed to low but not insignificant X-ray doses. ICRP based risk estimates indicate that the number of breast cancer casualties due to mammography screening can be as high as 50 in the Netherlands per year. The number of lives saved is estimated to be much higher, but for an accurate calculation of the benefits of screening a better estimate of these risks is indispensable. Here it is attempted to better quantify the radiological risks of mammography screening through the application of a biologically based model for breast tumor induction by X-rays. The model is applied to data obtained from the National Institutes of Health in the U.S. These concern epidemiological data of female TB patients who received high X-ray breast doses in the period 1930-1950 through frequent fluoroscopy of their lungs. The mechanistic model that is used to describe the increased breast cancer incidence is based on an earlier study by Moolgavkar et al. (1980), in which the natural background incidence of breast cancer was modeled. The model allows for a more sophisticated extrapolation of risks to the low dose X-ray exposures that are common in mammography screening and to the higher ages that are usually involved. Furthermore, it allows for risk transfer to other (non-western) populations. The results have implications for decisions on the frequency of screening, the number of mammograms taken at each screening, minimum and maximum ages for screening and the transfer to digital equipment. (author)

  13. Dose reduction through gridless technique in digital full-field mammography

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Berzeg, S.; Blick, U.; Fischer, T.; Hamm, B.

    2003-01-01

    Purpose: To determine the role of the scatter grid in digital full-field mammography with respect to image quality and dose and to compare the experimental results with initial clinical experience. Materials and Methods: A phantom consisting of 205 fields that enclose gold dots of different thickness and size (CD-Mam phantom, Medical Department, Nijmegen, Netherlands) was used for digital full-field mammography with the conventional grid module and a special gridless module. Four different breast thicknesses were simulated using Plexiglas as scatter material. First, the phantom was exposed at the parameter and dose settings automatically selected in each experimental setup (with and without grid). Subsequently, the phantom was exposed at the different simulated breast thicknesses using the gridless module in combination with the parameters automatically selected for the grid module. This was followed by a series of phantom mammograms obtained with the experimental setup reversed. The 16 mammograms were evaluated by 3 readers and the results compared considering breast thickness, radiation dose, and quality. The gridless module was used for preoperative labeling in 16 patients for comparison of mammograms obtained with and without a grid. Results: For the same entrance dose used in routine mammography, digital mammography without grid is superior to digital mammography with grid when performed on simulated thin breasts (Plexiglas less than 3 cm), with no difference found when performed on simulated large breasts. The advantages of gridless mammography are more pronounced at a markedly reduced entrance dose (identical parenchymal dose without and with grid using the dose automatically selected for the gridless module). This tendency is confirmed by the initial clinical comparison. (orig.) [de

  14. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Obenauer, S.; Hermann, K.P.

    2012-01-01

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  15. Health-related lifestyle factors and mammography screening attendance in a Swedish cohort study.

    Science.gov (United States)

    Lagerlund, Magdalena; Drake, Isabel; Wirfält, Elisabet; Sontrop, Jessica M; Zackrisson, Sophia

    2015-01-01

    To determine whether health-related lifestyle factors are associated with attendance at a population-based invitational mammography screening program in southern Sweden, data on health-related lifestyle factors (smoking, alcohol use, physical activity, BMI, diet, self-rated health, and stress) were obtained from the Malmö Diet and Cancer Study and linked to the Malmö mammography register (Sweden, 1992-2009). Women (n=11 409) who were free from breast cancer at study entry were included in the cohort, and mammography attendance was followed from cohort entry to 31 December 2009. Generalized estimating equations were used to account for repeated measures within patients. Adjusted odds ratios (OR) and 95% confidence intervals (CI) are reported. Nonattendance occurred in 8% of the 69 746 screening opportunities that were observed. Nonattendance was more common among women who were current or former smokers [OR=1.60 (1.45-1.76) and OR=1.15 (1.05-1.28)], had not used alcohol in the past year [OR=1.55 (1.32-1.83)], were less physically active outside of work [OR=1.10 (1.00-1.20)], had high physical activity at work (OR=1.13, 95% CI: 1.00-1.28), were vegetarians or vegans [OR=1.49 (1.11-1.99)], had not used dietary supplements [OR=1.11 (1.01-1.21)], had poor self-rated health [OR=1.24 (1.14-1.36)], and were experiencing greater stress [OR=1.25 (1.14-1.36)]. In this cohort, nonattendance was associated with smoking, alcohol abstinence, physical activity, poor self-rated health, stress, and following a vegetarian/vegan diet. These findings generally support the notion that women with less healthy lifestyles are less likely to engage in mammography screening.

  16. Added value of one-view breast tomosynthesis combined with digital mammography according to reader experience.

    Science.gov (United States)

    Thomassin-Naggara, Isabelle; Perrot, Nicolas; Dechoux, Sophie; Ribeiro, Carine; Chopier, Jocelyne; de Bazelaire, Cedric

    2015-02-01

    To retrospectively evaluate the added value of one-view breast tomosynthesis in adjunct with mammography to characterize breast lesions. Our institutional ethics committees approved the study and granted a waiver of informed consent. One hundred fifty-five women (mean age, 51.3 years, range: 24-92 years) who systematically underwent mammography and breast tomosynthesis with subsequent percutaneous biopsy were analyzed. Four radiologists (two seniors, R1 and R2, and two juniors, R3 and R4 with 30, 10, 3 and 1 years of experience in breast imaging, respectively) independently reviewed exams in two steps: mammography alone and tomosynthesis in adjunct with mammography. The lesions in the cohort included 39.3% (61/155) cancers, 2.5% (4/155) high-risk lesions and 58.1% (90/155) benign lesions. A receiver operating characteristic (ROC) curve analysis was performed to compare the results of the two readings. There was almost perfect agreement irrespective of reader experience for the reading of the mammography in adjunct with tomosynthesis, whereas agreement was poor between junior and senior readers for the reading of mammography alone. Area under the ROC (Az) values for the tomosynthesis in adjunct with mammography were significantly better than Az values for mammography alone for all readers except the most experienced, for whom only a tendency was noted. The proportion of cancers undiagnosed by mammography alone that were well diagnosed by tomosynthesis in adjunct with mammography was 6.5% (4/61), 13.1% (8/61), 27.8% (17/61) and 26.2% (16/61) for Readers 1, 2, 3 and 4, respectively. The proportion of false positive cases induced by the addition of breast tomosynthesis to mammography was 2.1% (2/94), 2.1% (2/94), 9.5% (9/94) and 12.7% (12/94) for Readers 1, 2, 3 and 4, respectively. Adding breast tomosynthesis to mammography improved sensitivity and negative predictive value for all readers except for the most experienced one, in whom only a tendency for improvement

  17. Added value of one-view breast tomosynthesis combined with digital mammography according to reader experience

    International Nuclear Information System (INIS)

    Thomassin-Naggara, Isabelle; Perrot, Nicolas; Dechoux, Sophie; Ribeiro, Carine; Chopier, Jocelyne; Bazelaire, Cedric de

    2015-01-01

    Highlights: • Breast tomosynthesis improves diagnostic performance especially for radiologists with lower experience in mammography. • Adding only one-view digital breast tomosynthesis to mammography improves the cancer detection rate. • Breast tomosynthesis is mainly useful for helping radiologists to detect architectural distortion. - Abstract: Purpose: To retrospectively evaluate the added value of one-view breast tomosynthesis in adjunct with mammography to characterize breast lesions. Materials and methods: Our institutional ethics committees approved the study and granted a waiver of informed consent. One hundred fifty-five women (mean age, 51.3 years, range: 24–92 years) who systematically underwent mammography and breast tomosynthesis with subsequent percutaneous biopsy were analyzed. Four radiologists (two seniors, R1 and R2, and two juniors, R3 and R4 with 30, 10, 3 and 1 years of experience in breast imaging, respectively) independently reviewed exams in two steps: mammography alone and tomosynthesis in adjunct with mammography. The lesions in the cohort included 39.3% (61/155) cancers, 2.5% (4/155) high-risk lesions and 58.1% (90/155) benign lesions. A receiver operating characteristic (ROC) curve analysis was performed to compare the results of the two readings. Results: There was almost perfect agreement irrespective of reader experience for the reading of the mammography in adjunct with tomosynthesis, whereas agreement was poor between junior and senior readers for the reading of mammography alone. Area under the ROC (Az) values for the tomosynthesis in adjunct with mammography were significantly better than Az values for mammography alone for all readers except the most experienced, for whom only a tendency was noted. The proportion of cancers undiagnosed by mammography alone that were well diagnosed by tomosynthesis in adjunct with mammography was 6.5% (4/61), 13.1% (8/61), 27.8% (17/61) and 26.2% (16/61) for Readers 1, 2, 3 and 4

  18. Added value of one-view breast tomosynthesis combined with digital mammography according to reader experience

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle, E-mail: isabelle.thomassin@tnn.aphp.fr [Sorbonne Universités, UPMC Univ Paris 06, IUC, 75005 Paris (France); INSERM, UMR970, Equipe 2, Imagerie de l’angiogenèse, 75005 Paris (France); AP-HP, Hôpital Tenon, Department of Radiology, 4 rue de la Chine, 75020 Paris (France); Perrot, Nicolas [AP-HP, Hôpital Tenon, Department of Radiology, 4 rue de la Chine, 75020 Paris (France); Centre Pyramides, Paris (France); Dechoux, Sophie [Sorbonne Universités, UPMC Univ Paris 06, IUC, 75005 Paris (France); AP-HP, Hôpital Tenon, Department of Radiology, 4 rue de la Chine, 75020 Paris (France); Ribeiro, Carine [Centre Pyramides, Paris (France); Chopier, Jocelyne [AP-HP, Hôpital Tenon, Department of Radiology, 4 rue de la Chine, 75020 Paris (France); Bazelaire, Cedric de [APHP, Department of Radiology, Hôpital Saint Louis, 75010 Paris (France)

    2015-02-15

    Highlights: • Breast tomosynthesis improves diagnostic performance especially for radiologists with lower experience in mammography. • Adding only one-view digital breast tomosynthesis to mammography improves the cancer detection rate. • Breast tomosynthesis is mainly useful for helping radiologists to detect architectural distortion. - Abstract: Purpose: To retrospectively evaluate the added value of one-view breast tomosynthesis in adjunct with mammography to characterize breast lesions. Materials and methods: Our institutional ethics committees approved the study and granted a waiver of informed consent. One hundred fifty-five women (mean age, 51.3 years, range: 24–92 years) who systematically underwent mammography and breast tomosynthesis with subsequent percutaneous biopsy were analyzed. Four radiologists (two seniors, R1 and R2, and two juniors, R3 and R4 with 30, 10, 3 and 1 years of experience in breast imaging, respectively) independently reviewed exams in two steps: mammography alone and tomosynthesis in adjunct with mammography. The lesions in the cohort included 39.3% (61/155) cancers, 2.5% (4/155) high-risk lesions and 58.1% (90/155) benign lesions. A receiver operating characteristic (ROC) curve analysis was performed to compare the results of the two readings. Results: There was almost perfect agreement irrespective of reader experience for the reading of the mammography in adjunct with tomosynthesis, whereas agreement was poor between junior and senior readers for the reading of mammography alone. Area under the ROC (Az) values for the tomosynthesis in adjunct with mammography were significantly better than Az values for mammography alone for all readers except the most experienced, for whom only a tendency was noted. The proportion of cancers undiagnosed by mammography alone that were well diagnosed by tomosynthesis in adjunct with mammography was 6.5% (4/61), 13.1% (8/61), 27.8% (17/61) and 26.2% (16/61) for Readers 1, 2, 3 and 4

  19. Screening for breast cancer with mammography

    International Nuclear Information System (INIS)

    Sickles, E.A.

    1991-01-01

    Mammography is generally accepted as a useful problem-solving clinical tool in characterizing known breast lesions, so that appropriate and timely treatment can be given. However, it remains grossly underutilized at what it does best: screening. The major strengths of mammography are (a) its ability to detect breast cancer at a smaller, potentially more curable stage than any other examination, and (b) its proved efficacy in reducing breast cancer mortality in asymptomatic women aged 40-74. If, as has recently been estimated, screening with mammography and physical examination can be expected to lower breast cancer deaths by 40%-50% among those actually examined (13), then the lives of almost 20,000 U.S. women might be saved each year if screening were to become very widely used. The challenges of the next decade are clear, to mount much more effective campaigns to educate physicians and lay women about the life-saving benefits of breast cancer screening, to devise increasingly effective and lower cost screening strategies, to further improve the current high quality of mammographic imaging despite its increasing proliferation, and to train large numbers of breast imaging specialists to guarantee that the growing case load of screening and problem-solving mammograms is interpreted with a very high level of skill

  20. Current approach for urinary system stone disease in pregnant women

    Directory of Open Access Journals (Sweden)

    Orcun Celik

    2016-01-01

    Full Text Available Urinary system stones can be classified according to size, location, X-ray characteristics, aetiology of formation, composition, and risk of recurrence. Especially urolithiasis during pregnancy is a diagnostic and therapeutic challenge. In most cases, it becomes symptomatic in the second or third trimester. Diagnostic options in pregnant women are limited due to the possible teratogenic, carcinogenic, and mutagenic risk of foetal radiation exposure. Clinical management of a pregnant urolithiasis patient is complex and demands close collaboration between patient, obstetrician and urologist. We would like to review current diagnosis and treatment modalities of stone disease of pregnant woman.

  1. Influence of age and menstrual cycle on mammography and MR imaging of the breast

    International Nuclear Information System (INIS)

    Mueller-Schimpfle, M.; Ohmenhaeuser, K.; Claussen, C.D.

    1997-01-01

    Age and menstrual cycle have an important influence on the breast. This well-known fact is experienced in the daily routine of gynecologists and radiologists. The number of publications addressing the effect of these influences on imaging, however, is surprisingly low. The aim of this work is to describe the influences of age and menstrual cycle on the breast and to address their clinical relevance for mammography and MR mammography. Therefore, own data are presented concerning the age and menstrual cycle influences on breast parenchyma in dynamic MR mammography. Literature data are used to correlate mammography and MR imaging findings with these influences. The changes of the breast due to age and menstrual cycle have important direct implications on performing and reading conventional mammography and MR mammography. The knowledge of these changes is also helpful in the interpretation of findings when comparing different methods. Finally, the data gained by using imaging methods enable important basic insights into physiology and physiopathology of the breast in vivo. (orig.) [de

  2. Is Short-Interval Mammography Necessary After Breast Conservation Surgery and Radiation Treatment in Breast Cancer Patients?

    International Nuclear Information System (INIS)

    Hymas, Richard V.; Gaffney, David K.; Parkinson, Brett T.; Belnap, Thomas W.; Sause, William T.

    2012-01-01

    Purpose: The optimum timing and frequency of mammography in breast cancer patients after breast-conserving therapy (BCT) are controversial. The American Society of Clinical Oncology recommends the first posttreatment mammogram 1 year after diagnosis but no earlier than 6 months after completion of radiotherapy. The National Comprehensive Cancer Network recommends annual mammography. Intermountain Healthcare currently follows a more frequent mammography schedule during the first 2 years in BCT patients. This retrospective study was undertaken to determine the cancer yield mammography during the first 2 years after BCT. Methods and Materials: 1,435 patients received BCT at Intermountain Healthcare between 2003 and 2007, inclusive. Twenty-three patients had bilateral breast cancer (1,458 total breasts). Patients were followed up for 24 months after diagnosis. The 1- and 2-year mammography yields were determined and compared with those of the general screening population. Results: 1,079 breasts had mammography at less than 1 year, and two ipsilateral recurrences (both noninvasive) were identified; 1,219 breasts had mammography during the second year, and nine recurrences (three invasive, six noninvasive) were identified. Of the 11 ipsilateral recurrences during the study, three presented with symptoms and eight were identified by mammography alone. The mammography yield was 1.9 cancers per 1,000 breasts the first year and 4.9 per 1,000 the second year. Conclusions: These data demonstrate that the mammography yield during the first 2 years after BCT is not greater than that in the general population, and they support the policy for initiating followup mammography at 1 year after BCT.

  3. Hidden costs of low-cost screening mammography

    International Nuclear Information System (INIS)

    Cyrlak, D.

    1987-01-01

    Twenty-two hundred women in Orange County, California, took part in a low-cost mammography screening project sponsored by the American Cancer Society and the KCBS-TV. Patients were followed up by telephone and questioned about actual costs incurred as a result of screening mammography, including costs of repeated and follow-up mammograms, US examinations and surgical consultations. The total number of biopsies, cancers found, and the costs involved were investigated. The authors' results suggest that particularly in centers with a high positive call rate, the cost of screening mammograms accounts for only a small proportion of the medical costs

  4. Focused two-dimensional antiscatter grid for mammography

    International Nuclear Information System (INIS)

    Makarova, O.V.; Moldovan, N.; Tang, C.-M.; Mancini, D.C.; Divan, R.; Zyryanov, V.N.; Ryding, D.C.; Yaeger, J.; Liu, C.

    2002-01-01

    We are developing freestanding high-aspect-ratio, focused, two-dimensional antiscatter grids for mammography using deep x-ray lithography and copper electroforming. The exposure is performed using x-rays from bending magnet beamline 2-BM at the Advanced Photon Source (APS) of Argonne National Laboratory. A 2.8-mm-thick prototype freestanding copper antiscatter grid with 25 (micro)m-wide parallel cell walls and 550 (micro)m periodicity has been fabricated. The progress in developing a dynamic double-exposure technique to create the grid with the cell walls aligned to a point x-ray source of the mammography system is discussed

  5. A Feasibility Study on the Application of Basic Oxygen Furnace (BOF Steel Slag for Railway Ballast Material

    Directory of Open Access Journals (Sweden)

    Taehoon Koh

    2018-01-01

    Full Text Available Railway ballast, for which natural crushed stone aggregates have been generally used, is an essential track component for the distribution of train loads along the rails and sleepers to the roadbed. However, the use of natural crushed stone aggregate causes environmental destruction as well as dust production in train service. This paper evaluates the feasibility of using the basic oxygen furnace (BOF steel slag as railway ballast material. A series of physical and chemical quality tests are performed to investigate the characteristics of the materials associated with the effect of aging period due to the remaining free CaO and MgO in the BOF steel slag. Three different aging periods (i.e., 0, 3, and 6 months are used to compare with various standards and the properties of the crushed stone aggregates. It is demonstrated that the physical and chemical properties of the BOF steel slag with different aging periods satisfy all requirements of standards sufficiently. Especially, the BOF steel slag without aging (i.e., 0 month provides the similar physical and chemical properties, when compared to the BOF steel slag with aging (i.e., 3 and 6 months. Thus, it is possible to apply the BOF steel slag regardless of aging periods to the railway ballast materials instead of natural crushed stone aggregates.

  6. Dual-energy CT for the evaluation of urinary calculi: Image interpretation, pitfalls and stone mimics

    International Nuclear Information System (INIS)

    Jepperson, M.A.; Cernigliaro, J.G.; Sella, D.; Ibrahim, E.; Thiel, D.D.; Leng, S.; Haley, W.E.

    2013-01-01

    Urolithiasis is a common disease with a reported prevalence between 4% and 20% in developed countries. Determination of urinary calculi composition is a key factor in preoperative evaluation, treatment, and stone recurrence prevention. Prior to the introduction of dual-energy computed tomography (DECT), available methods for determining urinary stone composition were only available after stone extraction, and thereby unable to aid in optimized stone management prior to intervention. DECT utilizes the attenuation difference produced by two different x-ray energy spectra to quantify urinary calculi composition as uric acid or non-uric acid (with likely further classification in the future) while still providing the information attained with a conventional CT. Knowledge of DECT imaging pitfalls and stone mimics is important, as the added benefit of dual-energy analysis is the determination of stone composition, which in turn affects all aspects of stone management. This review briefly describes DECT principles, scanner types and acquisition protocols for the evaluation of urinary calculi as they relate to imaging pitfalls (inconsistent characterization of small stones, small dual-energy field of view, and mischaracterization from surrounding material) and stone mimics (drainage devices) that may adversely impact clinical decisions. We utilize our clinical experience from scanning over 1200 patients with this new imaging technique to present clinically relevant examples of imaging pitfalls and possible mechanisms for resolution

  7. Renal pelvic stones: choosing shock wave lithotripsy or percutaneous nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Robert Marcovich

    2003-06-01

    Full Text Available Introduction of minimally invasive techniques has revolutionized the surgical management of renal calculi. Extracorporeal shock wave lithotripsy and percutaneous nephrolithotomy are now both well-established procedures. Each modality has advantages and disadvantages, and the application of each should be based on well-defined factors. These variables include stone factors such as number, size, and composition; factors related to the stone's environment, including the stone's location, spatial anatomy of the renal collecting system, presence of hydronephrosis, and other anatomic variables, such as the presence of calyceal diverticula and renal anomalies; and clinical or patient factors like morbid obesity, the presence of a solitary kidney, and renal insufficiency. The morbidity of each procedure in relation to its efficacy should be taken in to account. This article will review current knowledge and suggest an algorithm for the rational management of renal calculi with shock wave lithotripsy and percutaneous nephrolithotomy.

  8. Nutritional parameters of steers receiving different levels of sunflower crushed in partial replacement of soybean meal.

    Science.gov (United States)

    Lima, Hellen L; Goes, Rafael H T B de; Cerilo, Sara L N; Oliveira, Euclides R de; Gressler, Maria G M; Brabes, Kelly C S

    2013-01-01

    To evaluate of the sunflower crushed in nutritional parameters in steers, supplemented at pasture, we used four steers in 4×4 Latin square design. The supplements were provided in 6 g/kg of body weight/animal/day, consisting of sunflower crushed, corn, soybean meal and mineral. All the supplements was isonitrogenous and soybean meal was replaced in 0, 20, 40, and 60% for sunflower crushed. The determination of ruminal pH and ammonia was at 0, 2, 4, 6 and 8 h. after feeding and for short-chain fatty acids it was collected at 0 and 6 h. post-feeding. The dry matter intake was not affected (P>0.05) by inclusion of sunflower crushed (mean=6.59 kg/day). There was no significant effect (P>0.05) for pH for the inclusion of sunflower crushed (mean=6.41). For contents of ruminal NH₃-N was a significant effect (P replacement of soybean meal did not alter nutrition parameters.

  9. Upper urinary tract stone disease in patients with poor performance status: active stone removal or conservative management?

    Science.gov (United States)

    Yamashita, Shimpei; Kohjimoto, Yasuo; Hirabayashi, Yasuo; Iguchi, Takashi; Iba, Akinori; Higuchi, Masatoshi; Koike, Hiroyuki; Wakamiya, Takahito; Nishizawa, Satoshi; Hara, Isao

    2017-11-16

    It remains controversial as to whether active stone removal should be performed in patients with poor performance status because of their short life expectancy and perioperative risks. Our objectives were to evaluate treatment outcomes of active stone removal in patients with poor performance status and to compare life prognosis with those managed conservatively. We retrospectively reviewed 74 patients with Eastern Cooperative Oncology Group performance status 3 or 4 treated for upper urinary tract calculi at our four hospitals between January 2009 and March 2016. Patients were classified into either surgical treatment group or conservative management group based on the presence of active stone removal. Stone-free rate and perioperative complications in surgical treatment group were reviewed. In addition, we compared overall survival and stone-specific survival between the two groups. Cox proportional hazards analysis was performed to investigate predictors of overall survival and stone-specific survival. Fifty-two patients (70.3%) underwent active stone removal (surgical treatment group) by extracorporeal shock wave lithotripsy (n = 6), ureteroscopy (n = 39), percutaneous nephrolithotomy (n = 6) or nephrectomy (n = 1). The overall stone-free rate was 78.8% and perioperative complication was observed in nine patients (17.3%). Conservative treatment was undergone by 22 patients (29.7%) (conservative management group). Two-year overall survival rates in surgical treatment and conservative management groups were 88.0% and 38.4%, respectively (p performance status could be performed safely and effectively. Compared to conservative management, surgical stone treatment achieved longer overall survival and stone-specific survival.

  10. Management of ureteric stone in pediatric patients

    Directory of Open Access Journals (Sweden)

    Eugene Minevich

    2010-01-01

    Full Text Available The management of ureteral stones in children is becoming more similar to that in adults. A number of factors must be taken into account when selecting one′s choice of therapy for ureteral stone in children such as the size of the stone, its location, its composition, and urinary tract anatomy. Endoscopic lithotripsy in children has gradually become a major technique for the treatment of ureteral stones. The stone-free rate following urteroscopic lithotripsy for ureteral stones has been reported in as high as 98.5-100%. The safety and efficacy of Holmium:YAG laser lithotripsy make it the intracorporeal lithotriptor of choice. Given its minimally invasive features, extracorporeal shock wave lithotripsy (ESWL has become a primary mode of treatment for the pediatric patients with reno-ureteral stones. Stone-free rates have been reported from 59% to 91% although some patients will require more than one treatment session for stone clearance. It appears that the first-line of therapy in the child with distal and mid-ureteral stones should be ureteroscopic lithotripsy. While ESWL is still widely considered the first-line therapy for proximal ureteral calculi, there is an increasing body of evidence that shows that endoscopic or ESWL are equally safe and efficacious in those clinical scenarios. Familiarity with the full spectrum of endourological techniques facilitates a minimally invasive approach to pediatric ureteral stones.

  11. Correlation between Copper, Zinc and some lipids in serum, bile and stones of patients with gall stone disease

    International Nuclear Information System (INIS)

    Abu-Farsakh, F.

    1997-01-01

    Measurements of Cu, Zn and some lipid concentrations were carried out in serum, bile and gall stone samples collected from 76 patients undergoing surgery for removal of gall stones. The results showed that Cu and Zn were present in micromolar concentration in bile (average Cu concentration = 13.4 ± 0.92, average Zn concentration = 13.4 ± 1.05) and gall stones (average Cu concentration = 2.8 ± 0.16, average Zn concentration = 1.8 ± 0.16 mmol/ g stone). Cross-tabulation of the results showed significant positive linear correlations (p< 0.01) between stone Zn vs. bile cholesterol (r = 0.253), stone Zn vs. bile bilirubin (r = 0.396) (in mixed stones only). This suggested that the more hydrophobic the bile sample, the more Zn co-precipitate with cholesterol or bilirubin. (author). 17 refs., 3 tabs

  12. Natural radioactivity in granite stones and their radiological aspects as building material

    International Nuclear Information System (INIS)

    Kumaravel, S.; Sunil, C.N.; Narashimha Nath, V.; Raghunath, T.; Prashanth Kumar, M.; Ramakrishna, V.; Nair, B.S.K.; Purohit, R.G.; Tripati, R.M.

    2014-01-01

    Natural radioactivity in building and building decorating materials comes mainly from natural radioactive series like 238 U, 232 Th and 40 K. India is one of the leading users of granite stones as it is preferred by decorators and architects. The knowledge of presence of natural radioactivity in these materials is required for the assessment of radiation exposure due to them. The objective of this study is to determine the natural radioactivity and radiological aspects of granite stones as building material

  13. Mining geologic study in black san stones in Aguas Dulces, Rocha Province

    International Nuclear Information System (INIS)

    2002-01-01

    On September of the 2002 black san stones deposit were considered Uruguay mining reservation which it last 6 months. They were selected the best deposits areas which were carried out 37 drillings in 727.046 hectare as. The mineralogical composition and uses of Black san stones sampling were analyzed.. Field and laboratory studies were given as methodology. As conclusion they were found 933.000 tons of mineral like ilmenite, zircon, rut ilo, monazite and titanite equivalent to 65% all heavy metals.

  14. Sandvik sharpens in-pit crushing focus

    Energy Technology Data Exchange (ETDEWEB)

    Casteel, K.

    2009-04-15

    Major mining equipment supplier Sandvik Mining and Construction has announced a full-fledged fully mobile crushing plant, the PF300. This is shaping up to be the decade's major addition to the large scale open-cut mining toolkit. The PF300 can be connected to a face conveyor by a loading bridge as well as by belt wagon or transfer conveyor. The article describes design features. 2 figs.

  15. Artificial Neural Networks in Mammography Interpretation and Diagnostic Decision Making

    Directory of Open Access Journals (Sweden)

    Turgay Ayer

    2013-01-01

    Full Text Available Screening mammography is the most effective means for early detection of breast cancer. Although general rules for discriminating malignant and benign lesions exist, radiologists are unable to perfectly detect and classify all lesions as malignant and benign, for many reasons which include, but are not limited to, overlap of features that distinguish malignancy, difficulty in estimating disease risk, and variability in recommended management. When predictive variables are numerous and interact, ad hoc decision making strategies based on experience and memory may lead to systematic errors and variability in practice. The integration of computer models to help radiologists increase the accuracy of mammography examinations in diagnostic decision making has gained increasing attention in the last two decades. In this study, we provide an overview of one of the most commonly used models, artificial neural networks (ANNs, in mammography interpretation and diagnostic decision making and discuss important features in mammography interpretation. We conclude by discussing several common limitations of existing research on ANN-based detection and diagnostic models and provide possible future research directions.

  16. Abnormality Detection in Mammography using Deep Convolutional Neural Networks

    OpenAIRE

    Xi, Pengcheng; Shu, Chang; Goubran, Rafik

    2018-01-01

    Breast cancer is the most common cancer in women worldwide. The most common screening technology is mammography. To reduce the cost and workload of radiologists, we propose a computer aided detection approach for classifying and localizing calcifications and masses in mammogram images. To improve on conventional approaches, we apply deep convolutional neural networks (CNN) for automatic feature learning and classifier building. In computer-aided mammography, deep CNN classifiers cannot be tra...

  17. Simulation and modeling of the crushing behavior of structural members

    International Nuclear Information System (INIS)

    Toi, Yutaka

    1986-01-01

    The analysis of the crushing behavior (the behavior of compressive breakdown accompanied by super large deformation) of structural members is an important subject which becomes the base of the ultimate strength design of the structures which may cause collision accident such as automobiles, ships and aircrafts, and of those which are feared to be collided such as offshore structures, bridge piers and nuclear power plants. However, since it is a phenomenon of very strong nonlinearity, its analysis is accompanied by large difficulty. In this report, three kinds of the approach for this problem, that is, rigid-plastic theoretical analysis, the simulation using a rigid body and spring model and nonlinear finite element analysis, are explained, referring to the example of calculation by the authors on the non-axisymmetric crushing problem of cylindrical shells. In crushing problem, the matters of concern are the amount of collision energy which can be absorbed by the plastic deformation of structures and the amount of deformation. It can be said that the increase of calculation cost brings about the heightening of calculation accuracy. The nonlinear finite element analysis is promising because its calculation cost is expected to lower in future. (Kako, I.)

  18. Value of mammography and breast ultrasound in male patients with nipple discharge.

    Science.gov (United States)

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry

    International Nuclear Information System (INIS)

    Weinberg, I.; Majewski, S.; Weisenberger, A.; Markowitz, A.; Aloj, L.; Majewski, L,; Danforth, D.; Mulshine, J.; Cowan, K.; Zujewski, J.; Chow, C.; Jones, E.; Chang, V.; Berg, W.; Frank, J.

    1996-01-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed brest with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with potential for achieving X-ray correlation and image-guided biopsy. (orig.)

  20. Advances in percutaneous stone surgery

    OpenAIRE

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, ...

  1. Managed Care Penetration and the Use of Screening Mammography by Uninsured Women

    National Research Council Canada - National Science Library

    Garg, Pushkal

    2003-01-01

    ..., and increased waiting times for mammography. In this study, we examined whether there was an association between managed care penetration and rates of mammography among uninsured women between 50 and 64 years of age...

  2. On the possibility of reducing doses received by patients during mammography screening

    International Nuclear Information System (INIS)

    Tolwinski, J.; Fabiszewska, E.; Gwiazdowska, B.; Bulski, W.

    2005-01-01

    The aim of the study was to collect and to evaluate a set of data of a large group of patients examined with different mammography units, and to compare the individual doses (Di) with the standard average glandular dose (standard AGD) established for a particular mammography unit. The comparison was intended to allow to formulate recommendations of procedures in order to limit the exposure of patients, procedures which are beyond the scope of routine testing of mammography facilities. The presented analysis bases on the results of the measurements of the standard AGD, taken from 82 protocols of quality control of mammography equipment; - 16 histograms of dose distribution for individual patients (Di) examined with 16 different mammography units; - 2 histograms for patients examined with one mammography unit by the radiographer before and after training; - histograms of individual doses (Di), corresponding high-voltage (kV) and tube-loading (mAs) values, for one mammography unit (Elscint-Glory 2001) which was equipped with an automatic optimisation of contrast (AOC) system. The measurements were carried out according to the procedures of the American College of Radiology (ACR). Basing upon the constructed histograms we performed a comparison of the standard AGD values with the individual doses (Di). The frequency distribution of the standard AGDs (Figure 1) shows a considerable dispersion of values, ranging between 0.5 and 2.5 mGy. The histograms of the individual glandular doses (Di) calculated for individual patients, examined with different units (Figure 2) suggest that the choice of high voltage made by the radiographers may be incorrect i.e. the high voltage was not increased sufficiently with the increase of breast thickness. The incorrect value of the high voltage (low value) may be also set up by the AOC system (Figure 4). Two histograms for patients examined with one mammography unit by the radiographer before and after training (Figure 3) indicate the

  3. PIXE analysis of chinese chicken-blood stone

    International Nuclear Information System (INIS)

    Lin, E.K.; Wang, C.W.; Yu, Y.C.; Liu, T.Y.; Cheng, H.S.; Zhu, H.X.; Yang, H.J.

    1999-01-01

    This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al 2 O 3 and SiO 2 . The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

  4. Postmortem validation of breast density using dual-energy mammography

    Energy Technology Data Exchange (ETDEWEB)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A. [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

  5. Postmortem validation of breast density using dual-energy mammography

    International Nuclear Information System (INIS)

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer

  6. Estimating the relative utility of screening mammography.

    Science.gov (United States)

    Abbey, Craig K; Eckstein, Miguel P; Boone, John M

    2013-05-01

    The concept of diagnostic utility is a fundamental component of signal detection theory, going back to some of its earliest works. Attaching utility values to the various possible outcomes of a diagnostic test should, in principle, lead to meaningful approaches to evaluating and comparing such systems. However, in many areas of medical imaging, utility is not used because it is presumed to be unknown. In this work, we estimate relative utility (the utility benefit of a detection relative to that of a correct rejection) for screening mammography using its known relation to the slope of a receiver operating characteristic (ROC) curve at the optimal operating point. The approach assumes that the clinical operating point is optimal for the goal of maximizing expected utility and therefore the slope at this point implies a value of relative utility for the diagnostic task, for known disease prevalence. We examine utility estimation in the context of screening mammography using the Digital Mammographic Imaging Screening Trials (DMIST) data. We show how various conditions can influence the estimated relative utility, including characteristics of the rating scale, verification time, probability model, and scope of the ROC curve fit. Relative utility estimates range from 66 to 227. We argue for one particular set of conditions that results in a relative utility estimate of 162 (±14%). This is broadly consistent with values in screening mammography determined previously by other means. At the disease prevalence found in the DMIST study (0.59% at 365-day verification), optimal ROC slopes are near unity, suggesting that utility-based assessments of screening mammography will be similar to those found using Youden's index.

  7. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  8. Fresh and mechanical properties of self-compacting concrete with coarse aggregate replacement using Waste of Oil Palm Shell

    Science.gov (United States)

    Prayuda, Hakas; Saleh, Fadillawaty; Ilham Maulana, Taufiq; Monika, Fanny

    2018-05-01

    Self-compacting Concrete (SCC) is a real innovation that can solidify itself without the help of tools to ease field practice. In its implementation, SCC can use alternative materials to reduce waste, such as Oil Palm Shell (OPS). In this research, OPS used as a replacement of crushed stone as the main coarse aggregate. The concrete mixture used consists of cement, sand, crushed stone, OPS as a variation of aggregate substitutes, palm oil fuel ash, and superplasticizer. OPS used were variated with 0%, 5%, 10%, 25% and 50% of crushed stone aggregate weight with age up to 28 days. Tests were conducted on fresh and mechanical properties. From the results, it is known that replacement of aggregate using OPS meets fresh properties criteria and although the compressive strength of OPS concrete mixture is lower than normal SCC, OPS still can be an alternative in making SCC and reducing palm oil industrial waste.

  9. Digital Mammography in Young Women: Is a Single View Sufficient?

    Science.gov (United States)

    Gossner, Johannes

    2016-03-01

    Single view mammography may be a less time consuming, more comfortable and radiation reduced alternative for young women, but there are no studies examining this approach after the implementation of digital mammography into clinical practice. Retrospective analysis of all mammographies performed in women younger than 40 years during a 24 month period. The sample consisted of 109 women with 212 examined breasts. All patients initially received standard two- view mammography. In the study setting the MLO- views were read by a single viewer and compared to a composite reference standard. In this sample 7 malignant findings were present and the review of the MLO-view detected 6 of them (85%). In patients with dense breasts 4 out of 5 malignant findings were found on the single-view (sensitivity 80%) and all 2 malignant findings were detected in patients with low breast density (sensitivity 100%). There were 7 false positive findings (3.3%). i.e. in total 8 out of 212 examined breasts were therefore misinterpreted (3.8%). Single view digital mammography detects the vast majority of malignant findings, especially in low density breast tissue and the rate of false-positive findings is within acceptable limits. Therefore this approach may be used in different scenarios (for example in increasing patient throughout in resource poor settings, reducing radiation burden in the young or in combination with ultrasound to use the strengths of both methods). More research on this topic is needed to establish its potential role in breast imaging.

  10. Optimum nutrition for kidney stone disease.

    Science.gov (United States)

    Heilberg, Ita P; Goldfarb, David S

    2013-03-01

    We summarize the data regarding the associations of individual dietary components with kidney stones and the effects on 24-hour urinary profiles. The therapeutic recommendations for stone prevention that result from these studies are applied where possible to stones of specific composition. Idiopathic calcium oxalate stone-formers are advised to reduce ingestion of animal protein, oxalate, and sodium while maintaining intake of 800 to 1200 mg of calcium and increasing consumption of citrate and potassium. There are few data regarding dietary therapy of calcium phosphate stones. Whether the inhibitory effect of citrate sufficiently counteracts increasing urine pH to justify more intake of potassium and citrate is not clear. Reduction of sodium intake to decrease urinary calcium excretion would also be expected to decrease calcium phosphate stone recurrence. Conversely, the most important urine variable in the causation of uric acid stones is low urine pH, linked to insulin resistance as a component of obesity and the metabolic syndrome. The mainstay of therapy is weight loss and urinary alkalinization provided by a more vegetarian diet. Reduction in animal protein intake will reduce purine ingestion and uric acid excretion. For cystine stones, restriction of animal protein is associated with reduction in intake of the cystine precursor methionine as well as cystine. Reduction of urine sodium results in less urine cystine. Ingestion of vegetables high in organic anion content, such as citrate and malate, should be associated with higher urine pH and fewer stones because the amino acid cystine is soluble in more alkaline urine. Because of their infectious origin, diet has no definitive role for struvite stones except for avoiding urinary alkalinization, which may worsen their development. Published by Elsevier Inc.

  11. Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program

    Science.gov (United States)

    Zuckerman, Samantha P.; Keller, Brad M.; Maidment, Andrew D. A.; Barufaldi, Bruno; Weinstein, Susan P.; Synnestvedt, Marie; McDonald, Elizabeth S.

    2016-01-01

    Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board–approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016. PMID:27467468

  12. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  13. Effects of crushed conspecifics on growth and survival of Penaeus monodon Fabricius post larvae

    NARCIS (Netherlands)

    Nga, B.T.; Lürling, M.F.L.L.W.; Peeters, E.T.H.M.; Roijackers, R.M.M.; Scheffer, M.; Nghia, T.T.

    2006-01-01

    In the present study, the hypothesis tested was that Penaeus monodon post-larvae (PL) experience lower growth when exposed to crushed conspecifics, which was achieved by exposing individual P. monodon PL with abundant food for 4 weeks to a gradient from 0 to 100 crushed conspecific PL L1. Both dry

  14. Comparative study on mammographic findings between conventional mammography and digital mammography

    International Nuclear Information System (INIS)

    Gonzalez Calle, Aurelio; Saldarriaga Jaramillo, Ximena; Zapata Walliser, Luz Estela; Mejia Restrepo, Jorge Hernando; Arango Martinez, Adriana; Velez Arango, Jorge Mario

    2007-01-01

    We performed conventional-film mammograms in 180 patients between 35 and 6 years and additionally, we added 2 digital CR technique images to each patient, either craneocaudal (90 patients) or oblique (90 patients). All images were interpreted independently by four radiologists for a total of 720 evaluations, who compared film versus digital images through a 5 mega pixel monitor (soft-copy), using a score scale using the following parameters: mass visualization, detection of micro-calcifications, architectural distortion, visibility of the skin line, and image sharpness and noise. Additionally the tissue density was classified as well as the BIRADS score. The data was processed with the Teleform program and analyzed by de SPSSS program. Results: 52.6% of the micro-calcifications were equally visualized with both systems, in 13.5% of the cases they were better visualized with digital mammography. Similarly, in 50% of the cases, the skin line was better visualized with the digital CR modality. Conclusion: the sharpness of the image was also better seen with the digital CR technique in 48.2%. On the contrary, more noise was seen in digital CR images (63%). digital mammography is a diagnostic alternative that can improve mammographic findings detection and finally become a useful tool in breast cancer diagnosis

  15. [Controversial attitude to mammography screening in asymptomatic women between 40 and 50 years of age].

    Science.gov (United States)

    Frischbier, H J

    1994-01-01

    The results of screening studies conducted in the United States and in Europe in females between the ages of 40 and 50 are analysed. It is shown, that the results of this study on mortality reduction are less favourable, the poorer the technique of mammography (foregoing of general two-view mammography) and the longer the time interval between two mammography screenings. Arguments are presented, that are brought forward when declining to perform general mammography screening in this age group. The author's own results, obtained in the Hamburg mammography screening study, which included from 1971 to 1986 also premenopausal women, show, that the survival rates of patients below 50 years of age with mammographically detected carcinomas of the breast do not differ from those in patients older than 50 years, according to a relevant age group classification. The advances in the technique of mammography in recent years are analysed on the basis of the author's own patient material. It is evident, that the positive predictive value has been doubled, especially in the age group between 40 and 50. An analysis of the distribution of diagnosed noninvasive carcinomas compared with the invasive carcinomas reveals, that particularly this age group has the highest percentage of identification of prognostically favourable carcinoma stages. Further analyses show, why the randomised European mammography studies could not yield a significant mortality rate improvement. A prerequisite for the inclusion of mammography screening in the legally prescribed early detection of carcinoma examinations, however, are the quality controls, whose realisation, in our health system, will have to be confirmed by the German mammography study.

  16. ORIGINAL PAPER ORIG ORIG Percutaneous stone removal

    African Journals Online (AJOL)

    Percutaneous nephrolithotomy (PCNL) is an effective procedure to treat patients with complex renal stones,. e.g. staghorn calculi and stones greater than 20 mm in diameter. The treatment of choice for small, less com- plex renal stones is extracorporeal shock-wave litho- tripsy (ESWL).1 We have treated renal stones mainly.

  17. Implications of Overdiagnosis: Impact on Screening Mammography Practices

    Science.gov (United States)

    Morris, Elizabeth; Feig, Stephen A.; Drexler, Madeline

    2015-01-01

    Abstract This review article explores the issue of overdiagnosis in screening mammography. Overdiagnosis is the screen detection of a breast cancer, histologically confirmed, that might not otherwise become clinically apparent during the lifetime of the patient. While screening mammography is an imperfect tool, it remains the best tool we have to diagnose breast cancer early, before a patient is symptomatic and at a time when chances of survival and options for treatment are most favorable. In 2015, an estimated 231,840 new cases of breast cancer (excluding ductal carcinoma in situ) will be diagnosed in the United States, and some 40,290 women will die. Despite these data, screening mammography for women ages 40–69 has contributed to a substantial reduction in breast cancer mortality, and organized screening programs have led to a shift from late-stage diagnosis to early-stage detection. Current estimates of overdiagnosis in screening mammography vary widely, from 0% to upwards of 30% of diagnosed cancers. This range reflects the fact that measuring overdiagnosis is not a straightforward calculation, but usually one based on different sets of assumptions and often biased by methodological flaws. The recent development of tomosynthesis, which creates high-resolution, three-dimensional images, has increased breast cancer detection while reducing false recalls. Because the greatest harm of overdiagnosis is overtreatment, the key goal should not be less diagnosis but better treatment decision tools. (Population Health Management 2015;18:S3–S11) PMID:26414384

  18. Audit of mammography performed in our hospital

    International Nuclear Information System (INIS)

    Kantharia, Surita

    2013-09-01

    A medical audit is a compilation of patient outcomes over a certain period of time. Audit of Mammography provides an objective criterion of the appropriateness and accuracy in image interpretation, and is the best measure of a mammographer's performance. The audit assesses 3 important outcomes: i) detection of the percentage of cancers in a population, ii) finding these cancers while they are still curable (small and node negative), iii) finding these cancers through an acceptably low number of recalls and biopsies. With this background, I am presenting an audit of Mammography done at our centre from the period May 2010 to April 2013. (author)

  19. Managed Care Penetration and the Use of Screening Mammography by Uninsured Women

    National Research Council Canada - National Science Library

    Garg, Pushkal

    2002-01-01

    ..., and increased waiting times for mammography. In this study we propose to examine whether there is an association between managed care penetration and rates of mammography among uninsured women between 50 and 64 years of age...

  20. Performance of combined clinical mammography and needle biopsy: a nationwide study from Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Rank, Fritz; Dyreborg, Uffe

    2006-01-01

    Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine sensit...... with a suspicious or malignant result indicated a high risk of cancer, and excisional diagnostic biopsy therefore still has an important role to play.......Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine...

  1. Studies of breast masses in Korean woman using tungsten anode mammography

    International Nuclear Information System (INIS)

    Suh, C. O.; Oh, K. K.; Lee, K. S.

    1979-01-01

    Mammography is the oldest and most popular method in the diagnosis of breast disease and received the special attention as the powerful instrument in early detection of breast cancer. In Korea, the mammography has not been widely used, yet, but nowadays, increasing incidence of breast cancer and good prognosis after early detection and proper treatment need the clinical application of mammography for management of patient with breast disease and for the detection of occult cancer. The technique obtaining the good quality film is essential for improving the diagnostic accuracy of mammography in breast disease and in general, excellent film radiographs of breast can be obtained with proper combination of Kvp, processing, selection of fine grained film, fine focus tube and compression. In present study, radiographic technique was used in which 36-40 Kvp and 200 mAs were derived from a small focus Tungsten Anode tube. Medio-lateral and Cranio-caudad view were taken using Acryl compression device, which was specially designed by authors in order to properly examine the small, dense breasts of Korean women. Non-screen fine grained mammographic films was used and processing was manual.The materials consisted of 150 cases of mammography performed at Yonsei University Medical College, Severance Hospital, since January, 1978. We analyzed the diagnostic accuracy of mammography and mammographic findings in pathologically confirmed 39 cases. The conclusions are as follows: 1. Because women are sensitive to her breast changes, mammography is very useful not only in diagnosis of breast disease and early detection of cancer, but also management of patients with breast symptom and sign. 2. We obtained the relatively good quality film and high diagnostic accuracy with our own method, using conventional Tungsten Anode tube, compression device and hand processing. 3. We also applied specimen radiography in diagnosis of breast disease, which was helpful in verification of the adequacy

  2. Mammography Screening Among African-American Women with a Family History of Breast Cancer

    National Research Council Canada - National Science Library

    Lipkus, Issac

    1997-01-01

    Comparisons were made between African-American women with and without a family history of breast cancer with respect to mammography screening, attitudes towards mammography screening and perceptions...

  3. 77 FR 27245 - Big Stone National Wildlife Refuge, Big Stone and Lac Qui Parle Counties, MN

    Science.gov (United States)

    2012-05-09

    ... DEPARTMENT OF THE INTERIOR Fish and Wildlife Service [FWS-R3-R-2012-N069; FXRS1265030000S3-123-FF03R06000] Big Stone National Wildlife Refuge, Big Stone and Lac Qui Parle Counties, MN AGENCY: Fish and... plan (CCP) and environmental assessment (EA) for Big Stone National Wildlife Refuge (Refuge, NWR) for...

  4. The effect of inclined position on stone free rates in patients with lower caliceal stones during SWL session

    Directory of Open Access Journals (Sweden)

    Basri Cakiroglu

    2015-03-01

    Full Text Available Objective: To compare the outcomes of shock wave lithotripsy (SWL combined with inclined position and SWL alone in patients with lower pole calyx stones. Methods: Seven hundred forty patients who underwent SWL treatment for lower pole renal stones with a total diameter of 2 cm or less were prospectively randomized into two groups. They were comparable in terms of age, sex, and stone diameters. Patients with lower calyceal stones (4-20 mm were randomized to SWL (368 patients or SWL with simultaneous inclination (372 patients with 30o head down Trendelenburg position. Shock wave and session numbers were standardized according to stone size. Additional standardized shock waves were given to patients with stone fragments determined by kidney urinary bladder film and ultrasound at weeks 1, 4, 10. Results: The overall stone free rate (SFR was 73% (268/368 in patients with SWL alone and 81% (300/372 in SWL with inclination at the end of 12th week (p = 0.015. No significant adverse events were noted in both treatment groups. Conclusion: Simultaneous inclination of patients during SWL session increase SFR in lower caliceal stones significantly compared to SWL treatment alone.

  5. Compilation of historical dose to the breast received during mammography

    International Nuclear Information System (INIS)

    Thierry-Chef, Isabelle; Cardis, Elisabeth; Simon, Steven L.; Linet, Martha S.

    2008-01-01

    Full text: The effect of low to moderate diagnostic radiation exposures is a topic of interest currently in radiation protection and medicine. Most epidemiological studies, however, lack accurate information on doses received by individuals from medical diagnostic examinations. The need for a better assessment of doses from different types of radiographic examination, especially in the past is crucial for retrospective studies involving medical irradiation. The objective of the present study was to collect and review historic literature discussing radiation dose to the breast likely received from mammography as a function of year. Relevant publications related to mammography for time periods in the 20th century were collected and reviewed for data pertaining to doses to the breast. In many publications, dose to the breasts was not provided. However, it could be estimated in many cases from the dosimetric quantities reported, such as entrance surface dose, either by using provided technical parameters (kV, mAs, filtration) or by assuming typical values. The average value of dose to the breast was derived for each publication. Quality coefficients were derived to assign a greater weight to the most detailed and informative publications. From the dose data and the quality coefficients, a weighted average, minimum and maximum, by time period, were then estimated. Mammography has a long history, from its first use by Salomon in 1913 on 3000 mastectomy specimens to compare x-ray images with tumor lesions. Since then, mammography techniques have evolved in order to obtain better image quality with the objective of improving the diagnosis of breast cancer and other breast diseases. Major technology improvements were seen in the 1970's and 1980's resulting in modifications of medical protocols and consequential reductions of dose to the breast. Dose to the breast from a single view in mammography is presently about 10 times lower than it was in the 1960's when it was about

  6. Dosimetry in a torso phantom during a mammography

    International Nuclear Information System (INIS)

    Hernandez O, M.; Duran M, H. A.; Pinedo S, A.; Salas L, M. A.; Hernandez D, V. M.; Vega C, H. R.; Rivera M, T.; Ventura M, J.

    2009-10-01

    Two dosimetric magnitudes, the absorbed dose and the kerma in air to the entrance of torso have been determined. These dosimetric magnitudes are due to the radiation that is dispersed in the mammary gland when the patient undergoes a mammography study. The kerma to the entrance of the torso and the absorbed dose by the torso was obtained in a phantom of paraffin and with thermoluminescent dosemeters of ZrO 2 . The dosemeters were placed on the surface of the torso phantom while the mammography was carried out. (author)

  7. Knowledge about mammography and associated factors: population surveys with female adults and elderly

    Directory of Open Access Journals (Sweden)

    Ione Jayce Ceola Schneider

    2013-12-01

    Full Text Available The purpose of this paper is to describe the knowledge about mammography and to identify associated factors in female adults and elderly. Data were obtained from two population surveys, one with female adults and another with elderly women from Florianópolis (SC in 2009 - 2010. A descriptive analysis of the variables was carried out, the appropriate mean of responses about mammography was estimated and crude and adjusted Poisson regression was conducted to identify associated factors. Among adults, 23.1% answered all of the questions appropriately and the appropriate average responses was 7.2 (95%CI 7.1 - 7.3 in a total of 9. In the adjusted model, older age, higher education and income were associated with knowledge about mammography. For the elderly, 15.3% answered all questions appropriately and the average of appropriate responses was 6.4 (95%CI 5.2 - 6.5 and the factors associated with knowledge about mammography in the adjusted model were younger age groups, increased education and income, and identification of mammography as the main diagnostic method for breast cancer. Information about mammography can neither be transmitted in a clear way nor be easily understood; there are also demographic and socioeconomic differences concerning the knowledge about the exam.

  8. Stone comminution correlates with the average peak pressure incident on a stone during shock wave lithotripsy.

    Science.gov (United States)

    Smith, N; Zhong, P

    2012-10-11

    To investigate the roles of lithotripter shock wave (LSW) parameters and cavitation in stone comminution, a series of in vitro fragmentation experiments have been conducted in water and 1,3-butanediol (a cavitation-suppressive fluid) at a variety of acoustic field positions of an electromagnetic shock wave lithotripter. Using field mapping data and integrated parameters averaged over a circular stone holder area (R(h)=7 mm), close logarithmic correlations between the average peak pressure (P(+(avg))) incident on the stone (D=10 mm BegoStone) and comminution efficiency after 500 and 1000 shocks have been identified. Moreover, the correlations have demonstrated distinctive thresholds in P(+(avg)) (5.3 MPa and 7.6 MPa for soft and hard stones, respectively), that are required to initiate stone fragmentation independent of surrounding fluid medium and LSW dose. These observations, should they be confirmed using other shock wave lithotripters, may provide an important field parameter (i.e., P(+(avg))) to guide appropriate application of SWL in clinics, and facilitate device comparison and design improvements in future lithotripters. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Early myelin breakdown following sural nerve crush: a freeze-fracture study

    Directory of Open Access Journals (Sweden)

    Martinez A.M.B.

    2000-01-01

    Full Text Available In this study we describe the early changes of the myelin sheath following surgical nerve crush. We used the freeze-fracture technique to better evaluate myelin alterations during an early stage of Wallerian degeneration. Rat sural nerves were experimentally crushed and animals were sacrificed by transcardiac perfusion 30 h after surgery. Segments of the nerves were processed for routine transmission electron microscopy and freeze-fracture techniques. Our results show that 30 h after the lesion there was asynchrony in the pattern of Wallerian degeneration, with different nerve fibers exhibiting variable degrees of axon disruption. This was observed by both techniques. Careful examination of several replicas revealed early changes in myelin membranes represented by vacuolization and splitting of consecutive lamellae, rearrangement of intramembranous particles and disappearance of paranodal transverse bands associated or not with retraction of paranodal myelin terminal loops from the axolemma. These alterations are compatible with a direct injury to the myelin sheath following nerve crush. The results are discussed in terms of a similar mechanism underlying both axon and myelin breakdown.

  10. Breast imaging and reporting data system - Mammography. ACR BI-RADS registered -Mammography

    International Nuclear Information System (INIS)

    Fischer, U.; Helbrich, T.

    2006-01-01

    ACR BI-RADS registered mammography is an established technique in all German-speaking countries and has become a standard part of all mammographic findings. The first German-language edition three years ago made a significant contribution to this. This is the second, revised and edited edition. It is based on the fourth English-language edition of the ACR which was published in 2003. (orig.)

  11. Identification of Breast Cancer Using Integrated Information from MRI and Mammography.

    Directory of Open Access Journals (Sweden)

    Shih-Neng Yang

    Full Text Available Integration of information from corresponding regions between the breast MRI and an X-ray mammogram could benefit the detection of breast cancer in clinical diagnosis. We aimed to provide a framework of registration from breast MRI to mammography and to evaluate the diagnosis using the combined information.43 patients with 46 lesions underwent both MRI and mammography scans, and the interval between the two examinations was around one month. The distribution of malignant to benign lesions was 31/46 based on histological results. Maximum intensity projection and thin-plate spline methods were applied for image registration for MRI to mammography. The diagnosis using integrated information was evaluated using results of histology as the reference. The assessment of annotations and statistical analysis were performed by the two radiologists.For the cranio-caudal view, the mean post-registration error between MRI and mammography was 2.2±1.9 mm. For the medio-lateral oblique view, the proposed approach performed even better with a mean error of 3.0±2.4 mm. In the diagnosis using MRI assessment with information of mammography, the sensitivity was 91.9±2.3% (29/31, 28/31, specificity 70.0±4.7% (11/15, 10/15, accuracy 84.8±3.1% (40/46, 38/46, positive predictive value 86.4±2.1% (29/33, 28/33 and negative predictive value 80.8±5.4% (11/13, 10/13.MRI with the aid of mammography shows potential improvements of sensitivity, specificity, accuracy, PPV and NPV in clinical breast cancer diagnosis compared to the use of MRI alone.

  12. Barriers and incentives for choosing to specialise in mammography: Qualitative analysis

    International Nuclear Information System (INIS)

    Warren-Forward, H.M.; Taylor, J.

    2017-01-01

    Aim: There is a projected shortage of radiographers working in breast screening and this study aimed to examine comments from open response questions from a mixed methods survey of current diagnostic radiography students on their perceptions of working in mammography. Method: The survey asked three open ended questions: Justification of choice of modality in which they would want to specialise, why they believed there was a shortage of radiographers working in breast screening and any other comment about mammography. Results: Reasons given for specialising in any modality was interest, feature of a modality, amount of clinical exposure during the degree program, personal issues and career prospects. Few current diagnostic radiography students indicated that they would be interested in specialising in breast imaging. They considered there to be a shortage of radiographers as breast imaging was seen to be repetitive, high pressure, intimate and gender biased. Lack of education, clinical exposure, limited career prospects and low pay were also discussed. Conclusions: Increasing education to the modality during the degree, allowing males to be involved in breast imaging and promoting part-time work in mammography while also working in other modalities may alter the perception that mammography offers a limited career pathway. - Highlights: • Reasons to specialise in a modality include “interest”, “clinical exposure” and “career prospect”. • Reasons not to specialise include “availability of modality” and “gender of radiographer”. • Repetitive nature of mammography was cited as the most common reason for shortage of radiographers. • Restriction to female only radiographers was perceived to be a barrier. • Mammography perceived to be high stress due to pressure on getting correct diagnosis.

  13. ACR BI-RADS Assessment Category 4 Subdivisions in Diagnostic Mammography: Utilization and Outcomes in the National Mammography Database.

    Science.gov (United States)

    Elezaby, Mai; Li, Geng; Bhargavan-Chatfield, Mythreyi; Burnside, Elizabeth S; DeMartini, Wendy B

    2018-05-01

    Purpose To determine the utilization and positive predictive value (PPV) of the American College of Radiology (ACR) Breast Imaging Data and Reporting System (BI-RADS) category 4 subdivisions in diagnostic mammography in the National Mammography Database (NMD). Materials and Methods This study involved retrospective review of diagnostic mammography data submitted to the NMD from January 1, 2008 to December 30, 2014. Utilization rates of BI-RADS category 4 subdivisions were compared by year, facility (type, location, census region), and examination (indication, finding type) characteristics. PPV3 (positive predictive value for biopsies performed) was calculated overall and according to category 4 subdivision. The χ 2 test was used to test for significant associations. Results Of 1 309 950 diagnostic mammograms, 125 447 (9.6%) were category 4, of which 33.3% (41 841 of 125 447) were subdivided. Subdivision utilization rates were higher (P use, subdivisions were utilized in the minority (33.3% [41 841 of 125 447]) of category 4 diagnostic mammograms, with variability based on facility and examination characteristics. When subdivisions were used, PPV3s were in BI-RADS-specified malignancy ranges. This analysis supports the use of subdivisions in broad practice and, given benefits for patient care, should motivate increased utilization. © RSNA, 2018 Online supplemental material is available for this article.

  14. Our trial to improve patient positioning during mammography

    International Nuclear Information System (INIS)

    Nakayama, Takashi; Kotsuma, Yoshikazu; Hiramatsu, Sawako

    2007-01-01

    For effective breast cancer screening, reading of high-quality mammograms is essential, and for this purpose proper patient positioning during mammography is important. At our Shin-Osaka Mammography Seminar, which includes eight institutions, a physician and nine radiology technicians get together weekly in order to critically review mammogram reading and techniques for obtaining good mammograms. We have recognized that patient positioning has a great effect on mammogram quality, particularly for women in their 40 s who have dense mammary glands, and we have adopted a digital mammography system, or comparative mammography for such patients. Since July 2005, we have critically reviewed positioning every 3 or 4 months with the aim of improving our technique. Eight institutions have participated in this trial, each contributing mammograms taken recently from 20 to 30 consecutive participants, and the grade of positioning has been determined according to the Institutional Mammogram Estimation Standard (6 items, each scoring a maximum of 4 points, total 24 points) proposed by the Central Committee for Quality Control of Mammography Screening. The estimation has been done by both ourselves and committee members. When a total of 20 points or more is obtained and all 6 items score 3 points or more, it is considered that the positioning has been good, and this is termed ''Positioning A'' (P-A). On the other hand, if the total score is less than 20 points, and any one of the 6 items scores less than 3 points, it is considered that positioning has been inadequate, and this is termed ''Positioning-D'' (P-D). At the first review meeting, which was held before our critical study, P-A accounted for 48% of cases, and this had improved to 72% at the second meeting, and to 66% at the third. P-D accounted for 41% of cases at the first meeting, 20% at the second, and 21% at the third. Thus our trial involving discussion between a physician and technicians to critically review good

  15. Do Urinary Cystine Parameters Predict Clinical Stone Activity?

    Science.gov (United States)

    Friedlander, Justin I; Antonelli, Jodi A; Canvasser, Noah E; Morgan, Monica S C; Mollengarden, Daniel; Best, Sara; Pearle, Margaret S

    2018-02-01

    An accurate urinary predictor of stone recurrence would be clinically advantageous for patients with cystinuria. A proprietary assay (Litholink, Chicago, Illinois) measures cystine capacity as a potentially more reliable estimate of stone forming propensity. The recommended capacity level to prevent stone formation, which is greater than 150 mg/l, has not been directly correlated with clinical stone activity. We investigated the relationship between urinary cystine parameters and clinical stone activity. We prospectively followed 48 patients with cystinuria using 24-hour urine collections and serial imaging, and recorded stone activity. We compared cystine urinary parameters at times of stone activity with those obtained during periods of stone quiescence. We then performed correlation and ROC analysis to evaluate the performance of cystine parameters to predict stone activity. During a median followup of 70.6 months (range 2.2 to 274.6) 85 stone events occurred which could be linked to a recent urine collection. Cystine capacity was significantly greater for quiescent urine than for stone event urine (mean ± SD 48 ± 107 vs -38 ± 163 mg/l, p stone activity (r = -0.29, p r = -0.88, p r = -0.87, p stone quiescence. Decreasing the cutoff to 90 mg/l or greater improved sensitivity to 25.2% while maintaining specificity at 90.9%. Our results suggest that the target for capacity should be lower than previously advised. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Advances in percutaneous stone surgery.

    Science.gov (United States)

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, exit strategies, and post-operative antibiotic prophylaxis.

  17. Crushed tablets: does the administration of food vehicles and thickened fluids to aid medication swallowing alter drug release?

    Science.gov (United States)

    Manrique, Yady J; Lee, Danielle J; Islam, Faiza; Nissen, Lisa M; Cichero, Julie A Y; Stokes, Jason R; Steadman, Kathryn J

    2014-01-01

    To evaluate the influence of co-administered vehicles on in vitro dissolution in simulated gastric fluid of crushed immediate release tablets as an indicator for potential drug bioavailability compromise. Release and dissolution of crushed amlodipine, atenolol, carbamazepine and warfarin tablets were tested with six foods and drinks that are frequently used in the clinical setting as mixers for crushed medications (water, orange juice, honey, yoghurt, strawberry jam and water thickened with Easythick powder) in comparison to whole tablets. Five commercial thickening agents (Easythick Advanced, Janbak F, Karicare, Nutilis, Viscaid) at three thickness levels were tested for their effect on the dissolution of crushed atenolol tablets. Atenolol dissolution was unaffected by mixing crushed tablets with thin fluids or food mixers in comparison to whole tablets or crushed tablets in water, but amlodipine was delayed by mixing with jam. Mixing crushed warfarin and carbamazepine tablets with honey, jam or yoghurt caused them to resemble the slow dissolution of whole tablets rather than the faster dissolution of crushed tablets in water or orange juice. Crushing and mixing any of the four medications with thickened water caused a significant delay in dissolution. When tested with atenolol, all types of thickening agents at the greatest thickness significantly restricted dissolution, and products that are primarily based on xanthan gum also delayed dissolution at the intermediate thickness level. Dissolution testing, while simplistic, is a widely used and accepted method for comparing drug release from different formulations as an indicator for in vivo bioavailability. Thickened fluids have the potential to retard drug dissolution when used at the thickest levels. These findings highlight potential clinical implications of the addition of these agents to medications for the purpose of dose delivery and indicate that further investigation of thickened fluids and their

  18. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  19. Effect of stone coverage on soil erosion

    Science.gov (United States)

    Jomaa, S.; Barry, D. A.; Heng, B. P.; Brovelli, A.; Sander, G. C.; Parlange, J.

    2010-12-01

    Soil surface coverage has a significant impact on water infiltration, runoff and soil erosion yields. In particular, surface stones protect the soils from raindrop detachment, they retard the overland flow therefore decreasing its sediment transport capacity, and they prevent surface sealing. Several physical and environmental factors control to what extent stones on the soil surface modify the erosion rates and the related hydrological response. Among the most important factors are the moisture content of the topsoil, stone size, emplacement, coverage density and soil texture. Owing to the different inter-related processes, there is ambiguity concerning the quantitative effect of stones, and process-based understanding is limited. Experiments were performed (i) to quantify how stone features affect sediment yields, (ii) to understand the local effect of isolated surface stones, that is, the changes of the soil particle size distribution in the vicinity of a stone and (iii) to determine how stones attenuate the development of surface sealing and in turn how this affects the local infiltration rate. A series of experiments using the EPFL 6-m × 2-m erosion flume were conducted at different rainfall intensities (28 and 74 mm h-1) and stone coverage (20 and 40%). The total sediment concentration, the concentration of the individual size classes and the flow discharge were measured. In order to analyze the measurements, the Hairsine and Rose (HR) erosion model was adapted to account for the shielding effect of the stone cover. This was done by suitably adjusting the parameters based on the area not covered by stones. It was found that the modified HR model predictions agreed well with the measured sediment concentrations especially for the long time behavior. Changes in the bulk density of the topsoil due to raindrop-induced compaction with and without stone protection revealed that the stones protect the upper soil surface against the structural seals resulting in

  20. Bench-scale experimental determination of the thermal diffusivity of crushed tuff

    International Nuclear Information System (INIS)

    Ryder, E.E.; Finley, R.E.; George, J.T.; Ho, C.K.; Longenbaugh, R.S.; Connolly, J.R.

    1996-06-01

    A bench-scale experiment was designed and constructed to determine the effective thermal diffusivity of crushed tuff. Crushed tuff particles ranging from 12.5 mm to 37.5 mm (0.5 in. to 1.5 in.) were used to fill a cylindrical volume of 1.58 m 3 at an effective porosity of 0.48. Two iterations of the experiment were completed; the first spanning approximately 502 hours and the second 237 hours. Temperatures near the axial heater reached 700 degrees C, with a significant volume of the test bed exceeding 100 degrees C. Three post-test analysis techniques were used to estimate the thermal diffusivity of the crushed tuff. The first approach used nonlinear parameter estimation linked to a one dimensional radial conduction model to estimate thermal diffusivity from the first 6 hours of test data. The second method used the multiphase TOUGH2 code in conjunction with the first 20 hours of test data not only to estimate the crushed tuffs thermal diffusivity, but also to explore convective behavior within the test bed. Finally, the nonlinear conduction code COYOTE-II was used to determine thermal properties based on 111 hours of cool-down data. The post-test thermal diffusivity estimates of 5.0 x 10-7 m 2 /s to 6.6 x 10-7 m 2 /s were converted to effective thermal conductivities and compared to estimates obtained from published porosity-based relationships. No obvious match between the experimental data and published relationships was found to exist; however, additional data for other particle sizes and porosities are needed