WorldWideScience

Sample records for mammographic cad performance

  1. Improved mammographic interpretation of masses using computer-aided diagnosis

    International Nuclear Information System (INIS)

    Leichter, I.; Fields, S.; Novak, B.; Nirel, R.; Bamberger, P.; Lederman, R.; Buchbinder, S.

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p z ) increased significantly (p z for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the unassisted radiologist. Our findings suggest that objective quantitative features extracted from digitized mammographic findings may help in differentiating between benign and malignant masses, and can assist the radiologist in the interpretation of mass lesions. (orig.)

  2. Improved mammographic interpretation of masses using computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Leichter, I. [Dept. of Electro-Optics, Jerusalem College of Technology (Israel); Fields, S.; Novak, B. [Dept. of Radiology, Hadassah University Hospital, Mt. Scopus Jerusalem (Israel); Nirel, R. [Dept. of Statistics, Hebrew University of Jerusalem, Mt. Scopus, Jerusalem (Israel); Bamberger, P. [Dept. of Electronics, Jerusalem College of Technology, Jerusalem (Israel); Lederman, R. [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Buchbinder, S. [Department of Radiology, Montefiore Medical Center, University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States)

    2000-02-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p < 0.005) was found between features extracted by the CAD system for benign and malignant cases. Specificity of the CAD-assisted diagnosis improved significantly (p < 0.02) from 14 % for the conventional assessment to 50 %, and the positive predictive value increased from 0.47 to 0.62 (p < 0.04). The area under the ROC curve (A{sub z}) increased significantly (p < 0.001) from 0.66 for the conventional assessment to 0.81 for the CAD-assisted analysis. The A{sub z} for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that

  3. Characterization of mammographic masses based on level set segmentation with new image features and patient information

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan Heangping; Ge Jun; Hadjiiski, Lubomir; Helvie, Mark A.; Nees, Alexis; Wu Yita; Wei Jun; Zhou Chuan; Zhang Yiheng; Cui Jing

    2008-01-01

    Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based A z value of 0.83±0.01. The improvement compared to the previous CAD system was statistically significant (p=0.02). When patient age was included in the new CAD system, view-based and case-based A z values were 0.85±0.01 and 0.87±0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening

  4. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    International Nuclear Information System (INIS)

    Destounis, S.; Hanson, S.

    2007-01-01

    This study was conducted to retrospectively evaluate a computer-aided detection system's ability to detect breast carcinoma in multiple standard mammographic projections. Forty-five lesions in 44 patients imaged with digital mammography (Selenia registered , Hologic, Bedford, MA; Senographe registered , GE, Milwaukee, WI) and had computer-aided detection (CAD, Image-checker registered V 8.3.15, Hologic/R2, Santa Clara, CA) applied at the time of examination were identified for review; all were subsequently recommended to biopsy where cancer was revealed. These lesions were determined by the study Radiologist to be visible in both standard mammographic images (mediolateral oblique, MLO; craniocaudal, CC). For each patient, case data included patient age, tissue density, lesion type, BIRADS registered assessment, lesion size, lesion visibility-visible on MLO and/or CC view, ability of CAD to correctly mark the cancerous lesion, number of CAD marks per image, needle core biopsy results and surgical pathologic correlation. For this study cohort. CAD lesion/case sensitivity of 87% (n = 39) was found and image sensitivity was found to be 69% (n = 31) for MLO view and 78% (n = 35) for the CC view. For the study cohort, cases presented with a median of four marks per cases (range 0-13). Eighty-four percent (n = 38) of lesions proceeded to excision; initial needle biopsy pathology was upgraded at surgical excision from in situ disease to invasive for 24% (n = 9) lesions. CAD has demonstrated the potential to detect mammographically visible cancers in multiple standard mammographic projections in all categories of lesions in this study cohort. (orig.)

  5. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States); University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States); Hanson, Sarah; Morgan, Renee; Murphy, Philip; Somerville, Patricia; Seifert, Posy; Andolina, Valerie; Arieno, Andrea; Skolny, Melissa; Logan-Young, Wende [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States)

    2009-06-15

    A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRADS {sup registered} category 1 digital mammography examinations were randomly identified to serve as a comparative normal/control population. Data included patient age; BIRADS {sup registered} breast density; lesion type, size, and visibility; number, type, and location of CAD marks per image; CAD ability to mark lesions; needle core and surgical pathologic correlation. The CAD lesion/case sensitivity of 87% (n=39), image sensitivity of 69% (n=31) for mediolateral oblique view and 78% (n=35) for the craniocaudal view was found. The average false positive rate in 44 normal screening cases was 2.0 (range 1-8). The 2.0 figure is based on 88 reported false positive CAD marks in 44 normal screening exams: 98% (n=44) lesions proceeded to excision; initial pathology upgraded at surgical excision from in situ to invasive disease in 24% (n=9) lesions. CAD demonstrated potential to detect mammographically visible cancers in standard projections for all lesion types. (orig.)

  6. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  7. Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

    International Nuclear Information System (INIS)

    Sadaf, Arifa; Crystal, Pavel; Scaranelo, Anabel; Helbich, Thomas

    2011-01-01

    Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers.

  8. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2000-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  9. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2001-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  10. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    1999-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  11. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2002-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  12. Mammographic CAD: Correlation of regions in ipsilateral views – a ...

    African Journals Online (AJOL)

    Background. Radiologists analyse both standard mammographic views of a breast to confirm the presence of abnormalities and reduce false-positives. However, at present, no computer-aided diagnosis system uses ipsilateral mammograms to confirm the presence of suspicious features. Aim. The aim of this study was to ...

  13. Issues in assessing multi-institutional performance of BI-RADS-based CAD systems

    Science.gov (United States)

    Markey, Mia K.; Lo, Joseph Y.

    2005-04-01

    The purpose of this study was to investigate factors that impact the generalization of breast cancer computer-aided diagnosis (CAD) systems that utilize the Breast Imaging Reporting and Data System (BI-RADS). Data sets from four institutions were analyzed: Duke University Medical Center, University of Pennsylvania Medical Center, Massachusetts General Hospital, and Wake Forest University. The latter two data sets are subsets of the Digital Database for Screening Mammography. Each data set consisted of descriptions of mammographic lesions according to the BI-RADS lexicon, patient age, and pathology status (benign/malignant). Models were developed to predict pathology status from the BI-RADS descriptors and the patient age. Comparisons between the models built on data from the different institutions were made in terms of empirical (non-parametric) receiver operating characteristic (ROC) curves. Results suggest that BI-RADS-based CAD systems focused on specific classes of lesions may be more generally applicable than models that cover several lesion types. However, better generalization was seen in terms of the area under the ROC curve than in the partial area index (>90% sensitivity). Previous studies have illustrated the challenges in translating a BI-RADS-based CAD system from one institution to another. This study provides new insights into possible approaches to improve the generalization of BI-RADS-based CAD systems.

  14. Mammographic detection of breast arterial calcification as an independent predictor of coronary atherosclerotic disease in a single ethnic cohort of African American women

    NARCIS (Netherlands)

    Newallo, Domnique; Meinel, Felix G.; Schoepf, U. Joseph; Baumann, Stefan; De Cecco, Carlo N.; Leddy, Rebecca J.; Vliegenthart, Rozemarijn; Moellmann, Helge; Hamm, Christian W.; Morris, Pamela B.; Renker, Matthias

    Objective: Accumulating data on predominantly Caucasian women suggests an association between breast arterial calcification (BAC) and coronary artery disease (CAD). We sought to comprehensively examine the correlation between mammographic BAC and CAD endpoints detected by cardiac computed tomography

  15. Applying a new mammographic imaging marker to predict breast cancer risk

    Science.gov (United States)

    Aghaei, Faranak; Danala, Gopichandh; Hollingsworth, Alan B.; Stoug, Rebecca G.; Pearce, Melanie; Liu, Hong; Zheng, Bin

    2018-02-01

    Identifying and developing new mammographic imaging markers to assist prediction of breast cancer risk has been attracting extensive research interest recently. Although mammographic density is considered an important breast cancer risk, its discriminatory power is lower for predicting short-term breast cancer risk, which is a prerequisite to establish a more effective personalized breast cancer screening paradigm. In this study, we presented a new interactive computer-aided detection (CAD) scheme to generate a new quantitative mammographic imaging marker based on the bilateral mammographic tissue density asymmetry to predict risk of cancer detection in the next subsequent mammography screening. An image database involving 1,397 women was retrospectively assembled and tested. Each woman had two digital mammography screenings namely, the "current" and "prior" screenings with a time interval from 365 to 600 days. All "prior" images were originally interpreted negative. In "current" screenings, these cases were divided into 3 groups, which include 402 positive, 643 negative, and 352 biopsy-proved benign cases, respectively. There is no significant difference of BIRADS based mammographic density ratings between 3 case groups (p cancer detection in the "current" screening. Study demonstrated that this new imaging marker had potential to yield significantly higher discriminatory power to predict short-term breast cancer risk.

  16. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  17. Mammographic features of breast carcinoma: mammographic-pathologic correlation

    International Nuclear Information System (INIS)

    Gu Yajia; Wang Jiuhua; Chen Tongzhen; Zhang Tingqiu; Zhou Kangrong

    2003-01-01

    Objective: To analyze the mammographic features of breast carcinoma and the correlation between the mammographic and pathologic findings. Methods: A prospective study of 397 consecutive mammograms in patients with breast carcinoma, including infiltrating ductal carcinoma (IDC, n=297), ductal carcinoma in situ (DCIS) and DCIS associated with small invasive foci (n=38), mucinous carcinoma (n=21), medullary carcinoma (n=22) and invasive lobular carcinoma (n=19), was performed to determine the correlations between the mammographic and pathologic findings. Results: (1) Microcalcifications appeared in 170 cases (42.8%), a mass in 258 cases (65.0%), and distortion in 33 cases (8.3%), respectively. (2) Microcalcifications were more commonly associated with DCIS and IDC (χ 2 =30.90, P 2 =30.87, P 2 =27.40, P 2 =6.22, P 2 =7.19, P < 0.01). Conclusion: The common features of breast carcinoma in mammography were microcalcifications, microcalcifications with a mass, a mass, and distortion IDC was the commonest in breast carcinoma, and could be considered when mammographic malignant features above mentioned were found except the appearance of microcalcifications alone, which was firstly suggestive of DCIS. A mass also appeared in medullary and mucinous carcinoma, and distortion appeared in invasive lobular carcinoma

  18. Mammographic interpretation

    International Nuclear Information System (INIS)

    Tabor, L.

    1987-01-01

    For mammography to be an effective diagnostic method, it must be performed to a very high standard of quality. Otherwise many lesions, in particular cancer in its early stages, will simply not be detectable on the films, regardless of the skill of the mammographer. Mammographic interpretation consists of two basic steps: perception and analysis. The process of mammographic interpretation begins with perception of the lesion on the mammogram. Perception is influenced by several factors. One of the most important is the parenchymal pattern of the breast tissue, detection of pathologic lesions being easier with fatty involution. The mammographer should use a method for the systematic viewing of the mammograms that will ensure that all parts of each mammogram are carefully searched for the presence of lesions. The method of analysis proceeds according to the type of lesion. The contour analysis of primary importance in the evaluation of circumscribed tumors. After having analyzed the contour and density of a lesion and considered its size, the mammographer should be fairly certain whether the circumscribed tumor is benign or malignant. Fine-needle puncture and/or US may assist the mammographer in making this decision. Painstaking analysis is required because many circumscribed tumors do not need to be biopsied. The perception of circumscribed tumors seldom causes problems, but their analysis needs careful attention. On the other hand, the major challenge with star-shaped lesions is perception. They may be difficult to discover when small. Although the final diagnosis of a stellate lesion can be made only with the help of histologic examination, the preoperative mammorgraphic differential diagnosis can be highly accurate. The differential diagnostic problem is between malignant tumors (scirrhous carcinoma), on the one hand, and traumatic fat necrosis as well as radial scars on the other hand

  19. CAD: How it works, how to use it, performance

    International Nuclear Information System (INIS)

    Regge, Daniele; Halligan, Steve

    2013-01-01

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence

  20. CAD: How it works, how to use it, performance

    Energy Technology Data Exchange (ETDEWEB)

    Regge, Daniele, E-mail: daniele.regge@ircc.it [Institute for Cancer Research and Treatment, Candiolo-Torino (Italy); Halligan, Steve, E-mail: s.halligan@ucl.ac.uk [University College Hospital London, London (United Kingdom)

    2013-08-15

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence.

  1. Diagnostic implications of asymmetrical mammographic patterns

    International Nuclear Information System (INIS)

    Asenjo, M.; Ania, B.J.

    1997-01-01

    To analyze the effect of asymmetrical mammographic patterns of the diagnosis of breast cancer. In a series of 6, 476 patients referred to a Breast Imaging Diagnosis Unit, we excluded males, women with previous breast surgery, and cases in which mammography was not performed, which left 5,203 women included. Each breast was classified according to one of four patterns of mammographic parenchymal density. Asymmetry was considered to exist when a patient's breasts had different patterns. Breast cancer was confirmed histologically in 282 (5.4%) women. The mammographic pattern was asymmetrical in 8% of the women with cancer and in 2% of the women without cancer (p<0.001). Fine-needle aspiration biopsy was performed in 78% and 96% (p=0.04), respectively, of the women with and without mammographic asymmetry who had neoplasms, and in 33% and 22% (p=0.02), respectively, of the women with and without mammographic asymmetry who did not have neoplasms. Asymmetrical mammographic pattern was four times more frequent in the women with breast cancer. This asymmetry decreased the frequency of needle biopsy in women with cancer, but increased the frequency of needle biopsy in women without cancer. (Author) 11 refs

  2. Standalone computer-aided detection compared to radiologists' performance for the detection of mammographic masses

    International Nuclear Information System (INIS)

    Hupse, Rianne; Samulski, Maurice; Imhof-Tas, Mechli W.; Karssemeijer, Nico; Lobbes, Marc; Boetes, Carla; Heeten, Ard den; Beijerinck, David; Pijnappel, Ruud

    2013-01-01

    We developed a computer-aided detection (CAD) system aimed at decision support for detection of malignant masses and architectural distortions in mammograms. The effect of this system on radiologists' performance depends strongly on its standalone performance. The purpose of this study was to compare the standalone performance of this CAD system to that of radiologists. In a retrospective study, nine certified screening radiologists and three residents read 200 digital screening mammograms without the use of CAD. Performances of the individual readers and of CAD were computed as the true-positive fraction (TPF) at a false-positive fraction of 0.05 and 0.2. Differences were analysed using an independent one-sample t-test. At a false-positive fraction of 0.05, the performance of CAD (TPF = 0.487) was similar to that of the certified screening radiologists (TPF = 0.518, P = 0.17). At a false-positive fraction of 0.2, CAD performance (TPF = 0.620) was significantly lower than the radiologist performance (TPF = 0.736, P <0.001). Compared to the residents, CAD performance was similar for all false-positive fractions. The sensitivity of CAD at a high specificity was comparable to that of human readers. These results show potential for CAD to be used as an independent reader in breast cancer screening. (orig.)

  3. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  4. Ultrasound detection of nonpalpable mammographically occult malignancy

    International Nuclear Information System (INIS)

    Simpson, W.L.; Hermann, G.; Rausch, D.R.; Sherman, J.; Feig, S.A.; Bleiweiss, I.J.; Jaffer, S.

    2008-01-01

    To evaluate the prevalence of occult malignancy with screening breast ultrasound. All ultrasound-guided core needle breast biopsies performed between January 1, 1999, and June 30, 2001, were retrospectively reviewed. Lesions were identified during screening breast ultrasound in high-risk women with no mammographic or palpable abnormality in either breast, a unilateral mammographic or palpable abnormality in the contralateral breast, or a unilateral mammographic or palpable abnormality in a different quadrant of the same breast. All ultrasound-detected lesions were histologically verified. Six hundred and fifty-two women with a mean age of 49 years underwent 698 biopsies during the study period. Three hundred and forty-nine of these lesions were detected at screening breast ultrasound. Out of 349, 11 (3.2%) had a mammographically and clinically occult malignancy. Nine cancers were found in women with no mammographic or palpable abnormality. Two cancers were found in the same breast as the mammographic or palpable abnormality. None were found in the breast contralateral to a palpable or mammographic abnormality. Screening breast ultrasound of high-risk women has a similar detection rate for occult carcinoma as screening mammography, but has a low positive predictive value in cases where biopsy is performed. (author)

  5. Are unnecessary follow-up procedures induced by computer-aided diagnosis (CAD) in mammography? Comparison of mammographic diagnosis with and without use of CAD

    International Nuclear Information System (INIS)

    Marx, Christiane; Malich, Ansgar; Facius, Mirjam; Grebenstein, Uta; Sauner, Dieter; Pfleiderer, Stefan O.R.; Kaiser, Werner A.

    2004-01-01

    Objective: To evaluate the rate of unnecessary follow-up procedures recommended by radiologists using a CAD-system. Materials and methods: 185 patients (740 images) were consecutively selected from three groups (36 histologically proven cancers=group 1; 49 histologically proven benign lesions=group 2 and 100 screening cases (4 years-follow up=group 3). Mammograms were evaluated by a CAD system (Second Look [reg] , CADx, Canada). Five blinded radiologists assessed the images without/with CAD outputs. Diagnostic decisions were ranked from surely benign to surely malignant according to BIRADS classification, follow-up procedures were recommended for each observed lesion (a, screening; b, short interval follow-up examination in 6 months; c, pathologic clarification). Results: CAD-system detected 32/36 cancers (88.9%) (FP-rate: 1.04 massmarks and 0.27 calcmarks/image). The following values were reached by all observers without/with CAD in the mean: Sensitivity 80.6/80.0%, specificity 83.2/86.4%, PPV 53.1/58.1%, and NPV 94.6/94.7%. Observers described a similar number of additional lesions without/with the use of CAD (325/326). Whereas the number of unnecessary short-time follow up recommendations increased in all case-subgroups with CAD: 40.8/42.9% (group 1), 35.6/38.1% (group 2), 44.7/46.8% (group 3), respectively, the number of recommended biopsies decreased in all subgroups: group 1: 34.7/27.1%; group 2: 47.4/41.5%, group 3: 33.3/22.0%, respectively. Conclusion: In this rather small population additional usage of CAD led to a lower rate of unnecessary biopsies. The observed decrease of recommended unnecessary biopsies due to the usage of CAD in the screening group suggests a potential financial benefit by using CAD as diagnostic aid

  6. Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.

    Science.gov (United States)

    Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C

    2016-06-01

    The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.

  7. Mammographic image enhancement using wavelet transform and homomorphic filter

    Directory of Open Access Journals (Sweden)

    F Majidi

    2015-12-01

    Full Text Available Mammography is the most effective method for the early diagnosis of breast cancer diseases. As mammographic images contain low signal to noise ratio and low contrast, it becomes too difficult for radiologists to analyze mammogram. To deal with the above stated problems, it is very important to enhance the mammographic images using image processing methods. This paper introduces a new image enhancement approach for mammographic images which uses the modified mathematical morphology, wavelet transform and homomorphic filter to suppress the noise of images. For performance evaluation of the proposed method, contrast improvement index (CII and edge preservation index (EPI are adopted. Experimental results on mammographic images from Pejvak Digital Imaging Center (PDIC show that the proposed algorithm improves the two indexes, thereby achieving the goal of enhancing mammographic images.

  8. Anxiety in mammography: mammographers' and clients' perspectives

    International Nuclear Information System (INIS)

    Galletta, S.; Joel, N.; Maguire, R.; Weaver, K.; Poulos, A.

    2003-01-01

    The aim of this study was to identify causes of anxiety experienced by mammographers and clients during mammography and strategies to decrease the anxiety generated by the mammographic procedure. Two questionnaires were distributed: one to mammographers in public and private centres within NSW, the other to women (clients) who have experienced mammography. Mammographers' and clients' rankings of causes of clients' anxiety demonstrated many similarities indicating the mammographers' acknowledgement of factors contributing to client anxiety. Thematic analysis provided important qualitative data concerning anxiety experienced by both mammographers and clients and the influence of mammographer and client behaviour on that anxiety. The results of this study have provided important new knowledge for mammographic practice and mammography education. By understanding the causes of anxiety experienced by clients, mammographers can provide an informed, empathetic approach to the mammographic process. By acknowledging factors which increase their own anxiety mammographers can reduce the impact of this on themselves and on their clients. Copyright (2003) Australian Institute of Radiography

  9. Varying performance in mammographic interpretation across two countries: Do results indicate reader or population variances?

    Science.gov (United States)

    Soh, BaoLin P.; Lee, Warwick B.; Wong, Jill; Sim, Llewellyn; Hillis, Stephen L.; Tapia, Kriscia A.; Brennan, Patrick C.

    2016-03-01

    Aim: To compare the performance of Australian and Singapore breast readers interpreting a single test-set that consisted of mammographic examinations collected from the Australian population. Background: In the teleradiology era, breast readers are interpreting mammographic examinations from different populations. The question arises whether two groups of readers with similar training backgrounds, demonstrate the same level of performance when presented with a population familiar only to one of the groups. Methods: Fifty-three Australian and 15 Singaporean breast radiologists participated in this study. All radiologists were trained in mammogram interpretation and had a median of 9 and 15 years of experience in reading mammograms respectively. Each reader interpreted the same BREAST test-set consisting of sixty de-identified mammographic examinations arising from an Australian population. Performance parameters including JAFROC, ROC, case sensitivity as well as specificity were compared between Australian and Singaporean readers using a Mann Whitney U test. Results: A significant difference (P=0.036) was demonstrated between the JAFROC scores of the Australian and Singaporean breast radiologists. No other significant differences were observed. Conclusion: JAFROC scores for Australian radiologists were higher than those obtained by the Singaporean counterparts. Whilst it is tempting to suggest this is down to reader expertise, this may be a simplistic explanation considering the very similar training and audit backgrounds of the two populations of radiologists. The influence of reading images that are different from those that radiologists normally encounter cannot be ruled out and requires further investigation, particularly in the light of increasing international outsourcing of radiologic reporting.

  10. Minimization of annotation work: diagnosis of mammographic masses via active learning

    Science.gov (United States)

    Zhao, Yu; Zhang, Jingyang; Xie, Hongzhi; Zhang, Shuyang; Gu, Lixu

    2018-06-01

    The prerequisite for establishing an effective prediction system for mammographic diagnosis is the annotation of each mammographic image. The manual annotation work is time-consuming and laborious, which becomes a great hindrance for researchers. In this article, we propose a novel active learning algorithm that can adequately address this problem, leading to the minimization of the labeling costs on the premise of guaranteed performance. Our proposed method is different from the existing active learning methods designed for the general problem as it is specifically designed for mammographic images. Through its modified discriminant functions and improved sample query criteria, the proposed method can fully utilize the pairing of mammographic images and select the most valuable images from both the mediolateral and craniocaudal views. Moreover, in order to extend active learning to the ordinal regression problem, which has no precedent in existing studies, but is essential for mammographic diagnosis (mammographic diagnosis is not only a classification task, but also an ordinal regression task for predicting an ordinal variable, viz. the malignancy risk of lesions), multiple sample query criteria need to be taken into consideration simultaneously. We formulate it as a criteria integration problem and further present an algorithm based on self-adaptive weighted rank aggregation to achieve a good solution. The efficacy of the proposed method was demonstrated on thousands of mammographic images from the digital database for screening mammography. The labeling costs of obtaining optimal performance in the classification and ordinal regression task respectively fell to 33.8 and 19.8 percent of their original costs. The proposed method also generated 1228 wins, 369 ties and 47 losses for the classification task, and 1933 wins, 258 ties and 185 losses for the ordinal regression task compared to the other state-of-the-art active learning algorithms. By taking the

  11. Virtual colonoscopy: effect of computer-assisted detection (CAD) on radiographer performance

    International Nuclear Information System (INIS)

    Burling, D.; Moore, A.; Marshall, M.; Weldon, J.; Gillen, C.; Baldwin, R.; Smith, K.; Pickhardt, P.; Honeyfield, L.; Taylor, S.

    2008-01-01

    Aim: To investigate the effect of a virtual colonoscopy (VC) computed-assisted detection (CAD) system on polyp detection by trained radiographers. Materials and methods: Four radiographers trained in VC interpretation and utilization of CAD systems read a total of 62 endoscopically validated VC examinations containing 150 polyps (size range 5-50 mm) in four sessions, recording any polyps found and the examination interpretation time, first without and then with the addition of CAD as a 'second reader'. After a temporal separation of 6 weeks to reduce recall bias, VC examinations were re-read using 'concurrent reader' CAD. Interpretation times, polyp detection, and number of false-positives were compared between the different reader paradigms using paired t and paired exact tests. Results: Overall, use of 'second reader' CAD significantly improved polyp detection by 12% (p < 0.001, CI 6%,17%)) from 48 to 60%. There was no significant improvement using CAD as a concurrent reader (p = 0.20; difference of 7%, CI -3%, 16%) and no significant overall difference in recorded false-positives with second reader or concurrent CAD paradigms compared with unassisted reading (p = 0.25 and 0.65, respectively). The mean interpretation time was 21.7 min for unassisted reading, 29.6 (p < 0.001) min for second reader and 19.1 min (p = 0.12) for concurrent reading paradigms. Conclusion: CAD, when used as a second reader, can significantly improve radiographer reading performance with only a moderate increase in interpretation times

  12. Task-Specific Optimization of Mammographic Systems

    National Research Council Canada - National Science Library

    Saunders, Robert

    2005-01-01

    .... This model was verified by a human observer performance experiment. The next objective explored the physical properties of a digital mammographic system, including resolution, noise, efficiency, and lag...

  13. Reproducibility of prompts in computer-aided detection (CAD) of breast cancer

    International Nuclear Information System (INIS)

    Taylor, C.G.; Champness, J.; Reddy, M.; Taylor, P.; Potts, H.W.W.; Given-Wilson, R.

    2003-01-01

    AIM: We evaluated the reproducibility of prompts using the R2 ImageChecker M2000 computer-aided detection (CAD) system. MATERIALS AND METHODS: Forty selected two-view mammograms of women with breast cancer were digitized and analysed using the ImageChecker on 10 separate occasions. The mammograms were chosen to provide both straightforward and subtle signs of malignancy. Data analysed included mammographic abnormality, pathology, and whether the cancer was prompted or given an emphasized prompt. RESULTS: Correct prompts were generated in 86 out of 100 occasions for screen-detected cancers. Reproducibility was less in the other categories of more subtle cancers: 21% for cancers previously missed by CAD, a group that contained more grade 1 and small (<10 mm) tumours. Prompts for calcifications were more reproducible than those for masses (76% versus 53%) and these cancers were more likely to have an emphasized prompt. CONCLUSIONS: Probably the most important cause of variability of prompts is shifts in film position between sequential digitizations. Consequently subtle lesions that are only just above the threshold for display may not be prompted on repeat scanning. However, users of CAD should be aware that even emphasized prompts are not consistently reproducible

  14. A new and fast image feature selection method for developing an optimal mammographic mass detection scheme.

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    Selecting optimal features from a large image feature pool remains a major challenge in developing computer-aided detection (CAD) schemes of medical images. The objective of this study is to investigate a new approach to significantly improve efficacy of image feature selection and classifier optimization in developing a CAD scheme of mammographic masses. An image dataset including 1600 regions of interest (ROIs) in which 800 are positive (depicting malignant masses) and 800 are negative (depicting CAD-generated false positive regions) was used in this study. After segmentation of each suspicious lesion by a multilayer topographic region growth algorithm, 271 features were computed in different feature categories including shape, texture, contrast, isodensity, spiculation, local topological features, as well as the features related to the presence and location of fat and calcifications. Besides computing features from the original images, the authors also computed new texture features from the dilated lesion segments. In order to select optimal features from this initial feature pool and build a highly performing classifier, the authors examined and compared four feature selection methods to optimize an artificial neural network (ANN) based classifier, namely: (1) Phased Searching with NEAT in a Time-Scaled Framework, (2) A sequential floating forward selection (SFFS) method, (3) A genetic algorithm (GA), and (4) A sequential forward selection (SFS) method. Performances of the four approaches were assessed using a tenfold cross validation method. Among these four methods, SFFS has highest efficacy, which takes 3%-5% of computational time as compared to GA approach, and yields the highest performance level with the area under a receiver operating characteristic curve (AUC) = 0.864 ± 0.034. The results also demonstrated that except using GA, including the new texture features computed from the dilated mass segments improved the AUC results of the ANNs optimized

  15. Use of McCad for the conversion of ITER CAD data to MCNP geometry

    International Nuclear Information System (INIS)

    Tsige-Tamirat, H.; Fischer, U.; Serikov, A.; Stickel, S.

    2008-01-01

    The program McCad provides a CAD interface for the Monte Carlo transport code MCNP. It is able to convert CAD data into MCNP input geometry description and provides GUI components for modeling, visualization, and data exchange. It performs sequences of tests on CAD data to check its validity and neutronics appropriateness including completion of the final MCNP model by void geometries. McCad has been used to convert a 40 deg. ITER torus sector CAD model to a suitable MCNP geometry model. Results of MCNP calculations performed to validate the converted geometry are presented

  16. Computer-aided pulmonary nodule detection. Performance of two CAD systems at different CT dose levels

    International Nuclear Information System (INIS)

    Hein, Patrick Alexander; Rogalla, P.; Klessen, C.; Lembcke, A.; Romano, V.C.

    2009-01-01

    Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median also positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p>0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems. (orig.)

  17. Advanced techniques in digital mammographic images recognition

    International Nuclear Information System (INIS)

    Aliu, R. Azir

    2011-01-01

    Computer Aided Detection and Diagnosis is used in digital radiography as a second thought in the process of determining diagnoses, which reduces the percentage of wrong diagnoses of the established interpretation of mammographic images. The issues that are discussed in the dissertation are the analyses and improvement of advanced technologies in the field of artificial intelligence, more specifically in the field of machine learning for solving diagnostic problems and automatic detection of speculated lesions in digital mammograms. The developed of SVM-based ICAD system with cascade architecture for analyses and comparison mammographic images in both projections (CC and MLO) gives excellent result for detection and masses and microcalcifications. In order to develop a system with optimal performances of sensitivity, specificity and time complexity, a set of relevant characteristics need to be created which will show all the pathological regions that might be present in the mammographic image. The structure of the mammographic image, size and the large number of pathological structures in this area are the reason why the creation of a set of these features is necessary for the presentation of good indicators. These pathological structures are a real challenge today and the world of science is working in that direction. The doctoral dissertation showed that the system has optimal results, which are confirmed by experts, and institutions, which are dealing with these same issues. Also, the thesis presents a new approach for automatic identification of regions of interest in the mammographic image where regions of interest are automatically selected for further processing mammography in cases when the number of examined patients is higher. Out of 480 mammographic images downloaded from MIAS database and tested with ICAD system the author shows that, after separation and selection of relevant features of ICAD system the accuracy is 89.7% (96.4% for microcalcifications

  18. Mammographic screening programmes in Europe

    DEFF Research Database (Denmark)

    Giordano, Livia; von Karsa, Lawrence; Tomatis, Mariano

    2012-01-01

    To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe.......To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe....

  19. Performance of computer-aided detection in false-negative screening mammograms of breast cancers

    International Nuclear Information System (INIS)

    Han, Boo Kyung; Kim, Ji Young; Shin, Jung Hee; Choe, Yeon Hyeon

    2004-01-01

    To analyze retrospectively the abnormalities visible on the false-negative screening mammograms of patients with breast cancer and to determine the performance of computer-aided detection (CAD) in the detection of cancers. Of 108 consecutive cases of breast cancer diagnosed over a period of 6 years, of which previous screening mammograms were available, 32 retrospectively visible abnormalities (at which locations cancer later developed) were found in the previous mammograms, and which were originally reported as negative. These 32 patients ranged in age from 38 to 72 years (mean 52 years). We analyzed their previous mammographic findings, and assessed the ability of CAD to mark cancers in previous mammograms, according to the clinical presentation, the type of abnormalities and the mammographic parenchymal density. In these 32 previous mammograms of breast cancers (20 asymptomatic, 12 symptomatic), the retrospectively visible abnormalities were identified as densities in 22, calcifications in 8, and densities with calcifications in 2. CAD marked abnormalities in 20 (63%) of the 32 cancers with false-negative screening mammograms; 14 (70%) of the 20 subsequent screening-detected cancers, 5 (50%) of the 10 interval cancers, and 1 (50%) of the 2 cancers palpable after the screening interval. CAD marked 12 (50%) of the 24 densities and 9 (90%) of the 10 calcifications. CAD marked abnormalities in 7 (50%) of the 14 predominantly fatty breasts, and 13 (72%) of the 18 dense breasts. CAD-assisted diagnosis could potentially decrease the number of false-negative mammograms caused by the failure to recognize the cancer in the screening program, although its usefulness in the prevention of interval cancers appears to be limited

  20. Effect of Computer-Aided Detection on Mammographic Performance: Experimental Study on Readers with Different Levels of Experience

    International Nuclear Information System (INIS)

    Hukkinen, K.; Vehmas, T.; Pamilo, M.; Kivisaari, L.

    2006-01-01

    Purpose: To evaluate the effect of computer-aided detection (CAD) on the reader's performance. Material and Methods: Four screening radiologists, two novice radiologists, and two residents with no prior experience in CAD read films of 200 women without and with CAD. The films, including 16 screen-detected cancers and 35 cancers 'missed' on prior screening, were divided into two rollers: A (free time schedule) and B (prompted time schedule). Reading times were noted. Individual readings without and with CAD were compared, sensitivities and specificities were calculated. Results: The sensitivity of CAD was 70.6% and specificity 15.8%. In 408 cancer readings, the screeners found 10 and other readers 7 new cancers with the aid of CAD. The screeners changed their opinion four times and others six times from true positive to false negative when CAD was negative. CAD output produced 12 versus 13 new false-positive findings respectively after 2352 readings. CAD did not significantly affect the reader's sensitivities/specificities regardless of the time limit (P = not significant). The use of CAD increased mean time for roller reading from 56 to 63 min (P = 0.053). Conclusion: Screening radiologists benefited slightly more from CAD than other readers did, but no statistical significant difference was found in personal readings without and with CAD

  1. Fibroadenomas Frequency in uncertain mammographic lesions: Histology Correlation

    International Nuclear Information System (INIS)

    Hincapie Uribe, Ana Lucia; Patino Pacheco, Jairo H; Restrepo Mejia, Ana Lucia

    1997-01-01

    Purpose was to determine the frequency of fibroadenomas in non-palpable mammographic lesions, histologically evaluated and describe its radiological characteristics according to the type of mammographic presentation and classification. 60 (8.6%) fibroadenomas were found in 692 biopsies performed. 50% of these were mammographicaly classified as category 3 and 50% in the category 4. 66.6% of them were nodules, 20% isolated calcifications and nodules with calcifications 13.3%. fibroadenomas were 26.4% of nodules in category 3 and 18.8% of them in category 4

  2. Diagnostic Performance of Mammographic Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors.

    Science.gov (United States)

    Li, Zhiming; Yu, Lan; Wang, Xin; Yu, Haiyang; Gao, Yuanxiang; Ren, Yande; Wang, Gang; Zhou, Xiaoming

    2017-11-09

    The purpose of this study was to investigate the diagnostic performance of mammographic texture analysis in the differential diagnosis of benign and malignant breast tumors. Digital mammography images were obtained from the Picture Archiving and Communication System at our institute. Texture features of mammographic images were calculated. Mann-Whitney U test was used to identify differences between the benign and malignant group. The receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture features. Significant differences of texture features of histogram, gray-level co-occurrence matrix (GLCM) and run length matrix (RLM) were found between the benign and malignant breast group (P  .05). The AUROCs of imaging-based diagnosis, texture analysis, and imaging-based diagnosis combined with texture analysis were 0.873, 0.863, and 0.961, respectively. When imaging-based diagnosis was combined with texture analysis, the AUROC was higher than that of imaging-based diagnosis or texture analysis (P benign and malignant breast tumors. Furthermore, the combination of imaging-based diagnosis and texture analysis can significantly improve diagnostic performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Mammographic Breast Density in a Cohort of Medically Underserved Women

    Science.gov (United States)

    2015-12-01

    was a training year and during Years 2 through 4 a case-control study of obesity , insulin resistance and mammographic breast density was conducted. A...factors including health literacy, and to collect anthropometric measurements and fasting blood, 3) to assay blood for select hormones and growth...factors, 4) to perform statistical analyses to determine the associations between obesity and insulin resistance and mammographic breast density, and 5

  4. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  5. Performance and value of CAD-deficient pine- Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Bailian Li; Houmin Chang; Hasan Jameel

    2007-02-28

    The southern US produces 58% of the nation's timber, much of it grown in intensively managed plantations of genetically improved loblolly pine. One of the fastest-growing loblolly pine selections made by the NCSU-Industry Cooperative Tree Improvement Program, whose progeny are widely planted, is also the only known natural carrier of a rare gene, cadn1. This allele codes for deficiency in an enzyme, cinnamyl alcohol dehydrogenase, which catalyzes the last step in the biosynthesis of lignin precursors. This study is to characterize this candidate gene for marker-assisted selection and deployment in the breeding program. This research will enhance the sustainability of forest production in the South, where land-use pressures will limit the total area available in the future for intensively managed plantations. Furthermore, this research will provide information to establish higher-value plantation forests with more desirable wood/fiber quality traits. A rare mutant allele (cad-n1) of the cad gene in loblolly pine (Pinus taeda L.) causes a deficiency in the production of cinnamyl alcohol dehydrogenase (CAD). The effects of this allele were examined by comparing wood density and growth traits of cad-n1 heterozygous trees with those of wild-type trees in a 10-year-old open-pollinated family trial growing under two levels of fertilization in Scotland County, North Carolina. In all, 200 trees were sampled with 100 trees for each treatment. Wood density measurements were collected from wood cores at breast height using x-ray densitometry. We found that the substitution of cad-n1 for a wild-type allele (Cad) was associated with a significant effect on wood density. The cad-n1 heterozygotes had a significantly higher wood density (+2.6%) compared to wild-type trees. The higher density was apparently due to the higher percentage of latewood in the heterozygotes. The fertilization effect was highly significant for both growth and wood density traits. While no cad genotype

  6. Ethnicity, Soybean Consumption, and Mammographic Densities

    National Research Council Canada - National Science Library

    Maskarinec, Gertraud

    1997-01-01

    The purpose of this study is to determine whether mammographic density patterns differ by ethnic background and to explore the possible association of a soy rich diet with mammographic density patterns...

  7. Correlating Trainee Attributes to Performance in 3D CAD Training

    Science.gov (United States)

    Hamade, Ramsey F.; Artail, Hassan A.; Sikstrom, Sverker

    2007-01-01

    Purpose: The purpose of this exploratory study is to identify trainee attributes relevant for development of skills in 3D computer-aided design (CAD). Design/methodology/approach: Participants were trained to perform cognitive tasks of comparable complexity over time. Performance data were collected on the time needed to construct test models, and…

  8. Malignant Lesions as Mammographically Appearing Intramammary Ganglia

    International Nuclear Information System (INIS)

    Martinez-Miraveta, P.; Pons, M. J.; Pina, L. J.; Zornoza, G.

    2004-01-01

    Intramammary ganglia are frequent mammographic findings of no pathological importance. We present two cases of malignant breast lesions whose mammographic appearance could resemble that of intramammary ganglia. Although the mammographic appearance of a lesion is similar to that of intramammary ganglia, it should be carefully studied, especially if it presents a poorly defined border or is palpable. (Author)

  9. Mammographic appearances of male breast disease.

    Science.gov (United States)

    Appelbaum, A H; Evans, G F; Levy, K R; Amirkhan, R H; Schumpert, T D

    1999-01-01

    Various male breast diseases have characteristic mammographic appearances that can be correlated with their pathologic diagnoses. Male breast cancer is usually subareolar and eccentric to the nipple. Margins of the lesions are more frequently well defined, and calcifications are rarer and coarser than those occurring in female breast cancer. Gynecomastia usually appears as a fan-shaped density emanating from the nipple, gradually blending into surrounding fat. It may have prominent extensions into surrounding fat and, in some cases, an appearance similar to that of a heterogeneously dense female breast. Although there are characteristic mammographic features that allow breast cancer in men to be recognized, there is substantial overlap between these features and the mammographic appearance of benign nodular lesions. The mammographic appearance of gynecomastia is not similar to that of male breast cancer, but in rare cases, it can mask malignancy. Gynecomastia can be mimicked by chronic inflammation. All mammographically lucent lesions of the male breast appear to be benign, similar to such lesions in the female breast.

  10. Mucinous carcinoma of the breast: mammographic features with histologic correlation

    International Nuclear Information System (INIS)

    Cui Chunyan; Zhang Ling; Wu Yaopan; Li Shuqin

    2011-01-01

    Objective: To correlate the mammographic findings of mucinous carcinoma with histologic features. Methods: Retrospective analysis of the mammographic and pathologic findings of 37 patients with mucinous carcinomas of the breasts was performed. Results: Mammograms of ten (52.6%) women with mucinous carcinomas showed masses with well-defined, lobu-lated margins correlating well with the pure histologic type. Thirteen (81.3%) mixed type of mucinous carcinomas demonstrated poorly defined or spiculated margins (P<0.05). Most of the pure type carcinomas were hyperdense similar to most of mixed type carcinomas (P<0.05). Of 34 mucinous carcinomas tested, there were 25 ER-positive, 29 PR-positive, 24 C-erbB-2 negative expressions with pure type carcinomas accounting for 78.9%, 89.5% and 78.9%, respectively. Conclusion: The mammographic features of pure type are different from those of mixed type of mucinous breast carcinomas. The most common mammographic appearance of pure mucinous carcinoma is a well-defined mass without calcification whereas the mixed type carcinomas have more aggressive imaging characteristics. (authors)

  11. Improving the radiologist–CAD interaction: designing for appropriate trust

    International Nuclear Information System (INIS)

    Jorritsma, W.; Cnossen, F.; Ooijen, P.M.A. van

    2015-01-01

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist–CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the interaction between radiologists and the CAD system is not optimal. An important factor in the interaction between humans and automated aids (such as CAD) is trust. Suboptimal performance of the human–automation team is often caused by an inappropriate level of trust in the automation. In this review, we examine the role of trust in the radiologist–CAD interaction and suggest ways to improve the output of the CAD system so that it allows radiologists to calibrate their trust in the CAD system more effectively. Observer studies of the CAD systems show that radiologists often have an inappropriate level of trust in the CAD system. They sometimes under-trust CAD, thereby reducing its potential benefits, and sometimes over-trust it, leading to diagnostic errors they would not have made without CAD. Based on the literature on trust in human–automation interaction and the results of CAD observer studies, we have identified four ways to improve the output of CAD so that it allows radiologists to form a more appropriate level of trust in CAD. Designing CAD systems for appropriate trust is important and can improve the performance of the radiologist–CAD team. Future CAD research and development should acknowledge the importance of the radiologist–CAD interaction, and specifically the role of trust therein, in order to create the perfect artificial partner for the radiologist. This review focuses on the role of trust in the radiologist–CAD interaction. The aim of the review is to encourage CAD developers to design for appropriate trust and thereby improve the performance of the radiologist–CAD team. - Highlights: • Radiologists often have an inappropriate

  12. THE MAMMOGRAPHIC CALCIFICATIONS IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    Tang Ruiying; Liu Jingxian; Gaowen

    1998-01-01

    Objective: This study was performed to exam the relativeship between mammographic calcifications and breast cancer. Methods: All of the 184 patients with breast diseases underwent mammography before either an open biopsy or a mastectomy. The presence,morphology, and distribution of calcifications visualized on mammograms for breast cancer were compared with the controls who remained cancer free. Statistical comparisons were made by using the x2 test. Results:Of the 184 patients with breast diaeases, 93 malignant and 91 benign lesions were histologically confirmed.Calcifications were visualized on mammograms in 60(64%) of 93 breast cancers and 26 (28%) of 91 non breast cancers. The estimated odds ratio (OR) of breast cancer was 4.5 in women with calcifications seen on mammograms, compared with those having none (P<0.01). Of the 60 breast carcinomas having mammographic calcifications, 28 (47%) were infiltrating ductal carcinomas.There were only 8 (24%) cases with infiltrating ductal cancers in the group of without calcifications seen on the mammograms (P<0.05). Conclusion: Our finding suggests that mammographic calcification appears to be a risk factor for breast cancer. The granular and linear cast type calcification provide clues to the presence of breast cancer, especially when the carcinomas without associated masses were seen on mammograms.

  13. Contour tracing for segmentation of mammographic masses

    International Nuclear Information System (INIS)

    Elter, Matthias; Held, Christian; Wittenberg, Thomas

    2010-01-01

    CADx systems have the potential to support radiologists in the difficult task of discriminating benign and malignant mammographic lesions. The segmentation of mammographic masses from the background tissue is an important module of CADx systems designed for the characterization of mass lesions. In this work, a novel approach to this task is presented. The segmentation is performed by automatically tracing the mass' contour in-between manually provided landmark points defined on the mass' margin. The performance of the proposed approach is compared to the performance of implementations of three state-of-the-art approaches based on region growing and dynamic programming. For an unbiased comparison of the different segmentation approaches, optimal parameters are selected for each approach by means of tenfold cross-validation and a genetic algorithm. Furthermore, segmentation performance is evaluated on a dataset of ROI and ground-truth pairs. The proposed method outperforms the three state-of-the-art methods. The benchmark dataset will be made available with publication of this paper and will be the first publicly available benchmark dataset for mass segmentation.

  14. TGeoCad: an Interface between ROOT and CAD Systems

    International Nuclear Information System (INIS)

    Luzzi, C; Carminati, F

    2014-01-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems

  15. TGeoCad: an Interface between ROOT and CAD Systems

    Science.gov (United States)

    Luzzi, C.; Carminati, F.

    2014-06-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems.

  16. Breast cancer detection using sonography in women with mammographically dense breasts

    International Nuclear Information System (INIS)

    Okello, Jimmy; Kisembo, Harriet; Bugeza, Sam; Galukande, Moses

    2014-01-01

    Mammography, the gold standard for breast cancer screening misses some cancers, especially in women with dense breasts. Breast ultrasonography as a supplementary imaging tool for further evaluation of symptomatic women with mammographically dense breasts may improve the detection of mass lesions otherwise missed at mammography. The purpose of this study was to determine the incremental breast cancer detection rate using US scanning in symptomatic women with mammographically dense breasts in a resource poor environment. A cross sectional descriptive study. Women referred for mammography underwent bilateral breast ultrasound, and mammography for symptom evaluation. The lesions seen by both modalities were described using sonographic BI-RADS lexicon and categorized. Ultrasound guided core biopsies were performed. IRB approval was obtained and all participants provided informed written consent. In total 148 women with mammographically dense breasts were recruited over six months. The prevalence of breast cancer in symptomatic women with mammographically dense breasts was 22/148 (15%). Mammography detected 16/22 (73%) of these cases and missed 6/22 (27%). The six breast cancer cases missed were correctly diagnosed on breast ultrasonography. Sonographic features typical of breast malignancy were irregular shape, non-parallel orientation, non circumscribed margin, echogenic halo, and increased lesion vascularity (p values < 0.005). Typical sonofeatures of benign mass lesions were: oval shape, parallel orientation and circumscribed margin (p values <0.005). Breast ultrasound scan as a supplementary imaging tool detected 27% more malignant mass lesions otherwise missed by mammography among these symptomatic women with mammographically dense breasts. We recommend that ultra sound scanning in routine evaluation of symptomatic women with mammographically dense breasts

  17. Identification of simulated microcalcifications in white noise and mammographic backgrounds

    International Nuclear Information System (INIS)

    Reiser, Ingrid; Nishikawa, Robert M.

    2006-01-01

    This work investigates human performance in discriminating between differently shaped simulated microcalcifications embedded in white noise or mammographic backgrounds. Human performance was determined through two alternative forced-choice (2-AFC) experiments. The signals used were computer-generated simple shapes that were designed such that they had equal signal energy. This assured equal detectability. For experiments involving mammographic backgrounds, signals were blurred to account for the imaging system modulation transfer function (MTF). White noise backgrounds were computer generated; anatomic background patches were extracted from normal mammograms. We compared human performance levels as a function of signal energy in the expected difference template. In the discrimination task, the expected difference template is the difference between the two signals shown. In white noise backgrounds, human performance in the discrimination task was degraded compared to the detection task. In mammographic backgrounds, human performance in the discrimination task exceeded that of the detection task. This indicates that human observers do not follow the optimum decision strategy of correlating the expected signal template with the image. Human observer performance was qualitatively reproduced by non-prewhitening with eye filter (NPWE) model observer calculations, in which spatial uncertainty was explicitly included by shifting the locations of the expected difference templates. The results indicate that human strategy in the discrimination task may be to match individual signal templates with the image individually, rather than to perform template matching between the expected difference template and the image

  18. Nonpalpable breast cancer : mammographic and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-08-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group.

  19. Nonpalpable breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan

    1998-01-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group

  20. A uniform system for mammographic reporting BI-RADS

    International Nuclear Information System (INIS)

    Masroor, I.; Ahmad, M. N.; Sheikh, M. Y.

    2001-01-01

    Breast image reporting and data system (BI-RADS) is a new system of categorizing and reporting mammographs and mammographic findings recommended by American College of Radiology. The importance of BI-RADS and final assessment categories are discussed. The purpose is to introduce the above-mentioned mammographic reporting system so that it becomes a standard terminology among the medical personnel, involved in the diagnosis and management of breast diseases. (author)

  1. Epidemiologic Studies of Isoflavones & Mammographic Density

    Science.gov (United States)

    Maskarinec, Gertraud; Verheus, Martijn; Tice, Jeffrey A.

    2010-01-01

    Isoflavones, phytoestrogens in soy beans with estrogen-like properties, have been examined for their cancer protective effects. Mammographic density is a strong predictor of breast cancer. This review summarizes studies that have examined the association between isoflavones and breast density. Observational investigations in Hawaii and Singapore suggest slightly lower breast density among women of Asian descent with regular soy intake, but two larger studies from Japan and Singapore did not observe a protective effect. The findings from seven randomized trials with primarily Caucasian women indicate that soy or isoflavones do not modify mammographic density. Soy foods and isoflavone supplements within a nutritional range do not appear to modify breast cancer risk as assessed by mammographic density. PMID:22253990

  2. Epidemiologic Studies of Isoflavones & Mammographic Density

    Directory of Open Access Journals (Sweden)

    Jeffrey A. Tice

    2010-01-01

    Full Text Available Isoflavones, phytoestrogens in soy beans with estrogen-like properties, have been examined for their cancer protective effects. Mammographic density is a strong predictor of breast cancer. This review summarizes studies that have examined the association between isoflavones and breast density. Observational investigations in Hawaii and Singapore suggest slightly lower breast density among women of Asian descent with regular soy intake, but two larger studies from Japan and Singapore did not observe a protective effect. The findings from seven randomized trials with primarily Caucasian women indicate that soy or isoflavones do not modify mammographic density. Soy foods and isoflavone supplements within a nutritional range do not appear to modify breast cancer risk as assessed by mammographic density.

  3. Improved algorithms and advanced features of the CAD to MC conversion tool McCad

    International Nuclear Information System (INIS)

    Lu, L.; Fischer, U.; Pereslavtsev, P.

    2014-01-01

    Highlights: •The latest improvements of the McCad conversion approach including decomposition and void filling algorithms is presented. •An advanced interface for the materials editing and assignment has been developed and added to the McCAD GUI. •These improvements have been tested and successfully applied to DEMO and ITER NBI (Neutral Beam Injector) applications. •The performance of the CAD model conversion process is shown to be significantly improved. -- Abstract: McCad is a geometry conversion tool developed at KIT to enable the automatic bi-directional conversions of CAD models into the Monte Carlo (MC) geometries utilized for neutronics calculations (CAD to MC) and, reversed (MC to CAD), for visualization purposes. The paper presents the latest improvements of the conversion algorithms including improved decomposition, void filling and an advanced interface for the materials editing and assignment. The new implementations and features were tested on fusion neutronics applications to the DEMO and ITER NBI (Neutral Beam Injector) models. The results demonstrate greater stability and enhanced efficiency of McCad conversion process

  4. Association of Catechol-O-methyltransferase polymorphism Val158Met and mammographic density: A meta-analysis.

    Science.gov (United States)

    Kallionpää, Roope A; Uusitalo, Elina; Peltonen, Juha

    2017-08-15

    The Val158Met polymorphism in catechol-O-methyltransferase (COMT) enzyme reduces the methylation of catechol estrogens, which may affect mammographic density. High mammographic density is a known risk factor of breast cancer. Our aim was to perform meta-analysis of the effect of COMT Val158Met polymorphism on mammographic density. Original studies reporting data on mammographic density, stratified by the presence of COMT Val158Met polymorphism, were identified and combined using genetic models Met/Val vs. Val/Val, Met/Met vs. Val/Val, Val/Met+Met/Met vs. Val/Val (dominant model) and Met/Met vs. Val/Met+Val/Val (recessive model). Subgroup analyses by breast cancer status, menopausal status and use of hormone replacement therapy (HRT) were also performed. Eight studies were included in the meta-analysis. The overall effect in percent mammographic density was -1.41 (CI -2.86 to 0.05; P=0.06) in the recessive model. Exclusion of breast cancer patients increased the effect size to -1.93 (CI -3.49 to -0.37; P=0.02). The results suggested opposite effect of COMT Val158Met for postmenopausal users of HRT versus premenopausal women or postmenopausal non-users of HRT. COMT Val158Met polymorphism may be associated with mammographic density at least in healthy women. Menopausal status and HRT should be taken into account in future studies to avoid masking of the underlying effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Development of terminology for mammographic techniques for radiological technologists.

    Science.gov (United States)

    Yagahara, Ayako; Yokooka, Yuki; Tsuji, Shintaro; Nishimoto, Naoki; Uesugi, Masahito; Muto, Hiroshi; Ohba, Hisateru; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2011-07-01

    We are developing a mammographic ontology to share knowledge of the mammographic domain for radiologic technologists, with the aim of improving mammographic techniques. As a first step in constructing the ontology, we used mammography reference books to establish mammographic terminology for identifying currently available knowledge. This study proceeded in three steps: (1) determination of the domain and scope of the terminology, (2) lexical extraction, and (3) construction of hierarchical structures. We extracted terms mainly from three reference books and constructed the hierarchical structures manually. We compared features of the terms extracted from the three reference books. We constructed a terminology consisting of 440 subclasses grouped into 19 top-level classes: anatomic entity, image quality factor, findings, material, risk, breast, histological classification of breast tumors, role, foreign body, mammographic technique, physics, purpose of mammography examination, explanation of mammography examination, image development, abbreviation, quality control, equipment, interpretation, and evaluation of clinical imaging. The number of terms that occurred in the subclasses varied depending on which reference book was used. We developed a terminology of mammographic techniques for radiologic technologists consisting of 440 terms.

  6. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  7. Bilateral mammographic density asymmetry and breast cancer risk: A preliminary assessment

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Bin, E-mail: zhengb@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Sumkin, Jules H., E-mail: jsumkin@mail.magee.edu [Department of Radiology, Magee Womens Hospital, 300 Halket Street, Pittsburgh, PA 15213 (United States); Zuley, Margarita L., E-mail: zuleyml@upmc.edu [Department of Radiology, Magee Womens Hospital, 300 Halket Street, Pittsburgh, PA 15213 (United States); Wang, Xingwei, E-mail: wangx6@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Klym, Amy H., E-mail: klymah@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Gur, David, E-mail: gurd@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States)

    2012-11-15

    To improve efficacy of breast cancer screening and prevention programs, it requires a risk assessment model with high discriminatory power. This study aimed to assess classification performance of using computed bilateral mammographic density asymmetry to predict risk of individual women developing breast cancer in near-term. The database includes 451 cases with multiple screening mammography examinations. The first (baseline) examinations of all case were interpreted negative. In the next sequential examinations, 187 cases developed cancer or surgically excised high-risk lesions, 155 remained negative (not-recalled), and 109 were recalled benign cases. From each of two bilateral cranio-caudal view images acquired from the baseline examination, we computed two features of average pixel value and local pixel value fluctuation. We then computed mean and difference of each feature computed from two images. When applying the computed features and other two risk factors (woman's age and subjectively rated mammographic density) to predict risk of cancer development, areas under receiver operating characteristic curves (AUC) were computed to evaluate the discriminatory/classification performance. The AUCs are 0.633 {+-} 0.030, 0.535 {+-} 0.036, 0.567 {+-} 0.031, and 0.719 {+-} 0.027 when using woman's age, subjectively rated, computed mean and asymmetry of mammographic density, to classify between two groups of cancer-verified and negative cases, respectively. When using an equal-weighted fusion method to combine woman's age and computed density asymmetry, AUC increased to 0.761 {+-} 0.025 (p < 0.05). The study demonstrated that bilateral mammographic density asymmetry could be a significantly stronger risk factor associated to the risk of women developing breast cancer in near-term than woman's age and assessed mean mammographic density.

  8. Bilateral mammographic density asymmetry and breast cancer risk: A preliminary assessment

    International Nuclear Information System (INIS)

    Zheng, Bin; Sumkin, Jules H.; Zuley, Margarita L.; Wang, Xingwei; Klym, Amy H.; Gur, David

    2012-01-01

    To improve efficacy of breast cancer screening and prevention programs, it requires a risk assessment model with high discriminatory power. This study aimed to assess classification performance of using computed bilateral mammographic density asymmetry to predict risk of individual women developing breast cancer in near-term. The database includes 451 cases with multiple screening mammography examinations. The first (baseline) examinations of all case were interpreted negative. In the next sequential examinations, 187 cases developed cancer or surgically excised high-risk lesions, 155 remained negative (not-recalled), and 109 were recalled benign cases. From each of two bilateral cranio-caudal view images acquired from the baseline examination, we computed two features of average pixel value and local pixel value fluctuation. We then computed mean and difference of each feature computed from two images. When applying the computed features and other two risk factors (woman's age and subjectively rated mammographic density) to predict risk of cancer development, areas under receiver operating characteristic curves (AUC) were computed to evaluate the discriminatory/classification performance. The AUCs are 0.633 ± 0.030, 0.535 ± 0.036, 0.567 ± 0.031, and 0.719 ± 0.027 when using woman's age, subjectively rated, computed mean and asymmetry of mammographic density, to classify between two groups of cancer-verified and negative cases, respectively. When using an equal-weighted fusion method to combine woman's age and computed density asymmetry, AUC increased to 0.761 ± 0.025 (p < 0.05). The study demonstrated that bilateral mammographic density asymmetry could be a significantly stronger risk factor associated to the risk of women developing breast cancer in near-term than woman's age and assessed mean mammographic density.

  9. A comprehensive tool for measuring mammographic density changes over time.

    Science.gov (United States)

    Eriksson, Mikael; Li, Jingmei; Leifland, Karin; Czene, Kamila; Hall, Per

    2018-06-01

    Mammographic density is a marker of breast cancer risk and diagnostics accuracy. Density change over time is a strong proxy for response to endocrine treatment and potentially a stronger predictor of breast cancer incidence. We developed STRATUS to analyse digital and analogue images and enable automated measurements of density changes over time. Raw and processed images from the same mammogram were randomly sampled from 41,353 healthy women. Measurements from raw images (using FDA approved software iCAD) were used as templates for STRATUS to measure density on processed images through machine learning. A similar two-step design was used to train density measures in analogue images. Relative risks of breast cancer were estimated in three unique datasets. An alignment protocol was developed using images from 11,409 women to reduce non-biological variability in density change. The protocol was evaluated in 55,073 women having two regular mammography screens. Differences and variances in densities were compared before and after image alignment. The average relative risk of breast cancer in the three datasets was 1.6 [95% confidence interval (CI) 1.3-1.8] per standard deviation of percent mammographic density. The discrimination was AUC 0.62 (CI 0.60-0.64). The type of image did not significantly influence the risk associations. Alignment decreased the non-biological variability in density change and re-estimated the yearly overall percent density decrease from 1.5 to 0.9%, p density measures was not influenced by mammogram type. The alignment protocol reduced the non-biological variability between images over time. STRATUS has the potential to become a useful tool for epidemiological studies and clinical follow-up.

  10. Retrospective analysis of a Computer-Aided Detection (CAD) system in full-field digital mammography in correlation to tumor histology

    International Nuclear Information System (INIS)

    Obenauer, S.; Sohns, C.; Grabbe, E.; Werner, C.

    2005-01-01

    Purpose: to evaluate the usefulness of a computer-aided detection (CAD) system in full-field digital mammography in correlation to tumor histology. Material and methods: a total of 476 patients (226 patients with histologically proven malignant tumors, 250 healthy women) took part in this study. The mammograms were studied retrospectively, using the CAD system Image Checker. For 226 patients digital mammograms in MLO-projection were available. For 186 of these patients the CC-projection was also available. CAD markers that correlated with histologically proven carcinomas were considered to be true-positive markers. All other CAD markers were considered to be false-positive. Histologically proven carcinomas without markers were false-negative results. The dependence of the CAD markers placement upon the different carcinoma histologies was studied using the Chi-square test. Results: no significant difference could be proven for the detectability of malignant breast lesions of different histologic types. For the detectability of ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), lobular carcinoma in situ (LCIS), tubular carcinoma and ductulo-lobular carcinoma, the true positives were 71.1%, 75%, 70.7%, 70%, 60% and 80%, respectively, in the MLO projection and 83.9%, 75.9%, 81.8%, 77.8%, 87.5% and 33.3%, respectively, in the CC projection. There was an average of 0.5 false-positive markers per mammographic image. Conclusion: The histologic type of carcinoma seems to have no influence on detectability when using the CAD system. The high rate of false-positive markers shows, however, the limited specificity of the CAD system and that improvements are necessary. (orig.)

  11. Fractal analysis of visual search activity for mass detection during mammographic screening.

    Science.gov (United States)

    Alamudun, Folami; Yoon, Hong-Jun; Hudson, Kathleen B; Morin-Ducote, Garnetta; Hammond, Tracy; Tourassi, Georgia D

    2017-03-01

    The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) from 10 readers (three board certified radiologists and seven Radiology residents), formed the corpus for this study. The fractal dimension of the readers' visual scanning pattern was computed with the Minkowski-Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the complexity of visual scanning pattern when screening for breast cancer. No higher order effects were found to be significant. Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics. © 2017 American Association of Physicists in Medicine.

  12. Structural design by CAD system

    International Nuclear Information System (INIS)

    Kim, Jhin Wung; Shim, Jae Ku; Kim, Sun Hoon; Kim, Dae Hong; Lee, Kyung Jin; Choi, Kyu Sup; Choi, In Kil; Lee, Dong Yong

    1988-12-01

    CAD systems are now widely used for the design of many engineering problems involving static, dynamic and thermal stress analyses of structures. In order to apply CAD systems to the structural analysis and design, the function of hardwares and softwares necessary for the CAD systems must be understood. The purpose of this study is to introduce the basic elements that are indispensible in the application of CAD systems to the analysis and design of structures and to give a thorough understanding of CAD systems to design engineers, so as to participate in the further technological developments of CAD systems. Due to the complexity and variety of the shape and size of the nowa-days structures, the need of new design technologies is growing for more efficient, accurate and economical design of structures. The application of CAD systems to structural engineering fields enables to improve structural engineering analysis and design technologies and also to obtain the standardization of the design process. An active introduction of rapidly developing CAD technologies will contribute to analyzing and designing structures more efficiently and reliably. Based on this report of the current status of the application of CAD systems to the structural analysis and design, the next goal is to develop the expert system which enables to perform the design of structures by CAD systems from the preliminary conceptual design to the final detail drawings automatically. (Author)

  13. CAD-guidelines

    International Nuclear Information System (INIS)

    Schlechtendahl, E.G.; Lang-Lendorff, G.

    1982-10-01

    The CAD-guidelines (CAD = Computer Aided Design) contain rules for programming, structuring and documentation of programs. The standard deals with the structure of CAD-programs, their components, the programming-methods, the language etc. It describes what documents and references are necessary for a CAD-program. In order to gain a broad application of CAD criteria like portability and completeness of the documentation for an effective maintenance are as important as a transparent way of producing CAD-software. (orig.) [de

  14. Monte Carlo simulation of a mammographic test phantom

    International Nuclear Information System (INIS)

    Hunt, R. A.; Dance, D. R.; Pachoud, M.; Carlsson, G. A.; Sandborg, M.; Ullman, G.

    2005-01-01

    A test phantom, including a wide range of mammographic tissue equivalent materials and test details, was imaged on a digital mammographic system. In order to quantify the effect of scatter on the contrast obtained for the test details, calculations of the scatter-to-primary ratio (S/P) have been made using a Monte Carlo simulation of the digital mammographic imaging chain, grid and test phantom. The results show that the S/P values corresponding to the imaging conditions used were in the range 0.084-0.126. Calculated and measured pixel values in different regions of the image were compared as a validation of the model and showed excellent agreement. The results indicate the potential of Monte Carlo methods in the image quality-patient dose process optimisation, especially in the assessment of imaging conditions not available on standard mammographic units. (authors)

  15. Improving the radiologist-CAD interaction : designing for appropriate trust

    NARCIS (Netherlands)

    Jorritsma, W.; Cnossen, F.; van Ooijen, P. M. A.

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist-CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the

  16. Serum osteoprotegerin levels and mammographic density among high-risk women.

    Science.gov (United States)

    Moran, Olivia; Zaman, Tasnim; Eisen, Andrea; Demsky, Rochelle; Blackmore, Kristina; Knight, Julia A; Elser, Christine; Ginsburg, Ophira; Zbuk, Kevin; Yaffe, Martin; Narod, Steven A; Salmena, Leonardo; Kotsopoulos, Joanne

    2018-06-01

    Mammographic density is a risk factor for breast cancer but the mechanism behind this association is unclear. The receptor activator of nuclear factor κB (RANK)/RANK ligand (RANKL) pathway has been implicated in the development of breast cancer. Given the role of RANK signaling in mammary epithelial cell proliferation, we hypothesized this pathway may also be associated with mammographic density. Osteoprotegerin (OPG), a decoy receptor for RANKL, is known to inhibit RANK signaling. Thus, it is of interest to evaluate whether OPG levels modify breast cancer risk through mammographic density. We quantified serum OPG levels in 57 premenopausal and 43 postmenopausal women using an enzyme-linked immunosorbent assay (ELISA). Cumulus was used to measure percent density, dense area, and non-dense area for each mammographic image. Subjects were classified into high versus low OPG levels based on the median serum OPG level in the entire cohort (115.1 pg/mL). Multivariate models were used to assess the relationship between serum OPG levels and the measures of mammographic density. Serum OPG levels were not associated with mammographic density among premenopausal women (P ≥ 0.42). Among postmenopausal women, those with low serum OPG levels had higher mean percent mammographic density (20.9% vs. 13.7%; P = 0.04) and mean dense area (23.4 cm 2 vs. 15.2 cm 2 ; P = 0.02) compared to those with high serum OPG levels after covariate adjustment. These findings suggest that low OPG levels may be associated with high mammographic density, particularly in postmenopausal women. Targeting RANK signaling may represent a plausible, non-surgical prevention option for high-risk women with high mammographic density, especially those with low circulating OPG levels.

  17. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    International Nuclear Information System (INIS)

    Annovazzi, A.; Amendolia, S.R.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Colombo, F.; Delogu, P.; Fantacci, M.E.; Gilberti, A.; Lanzieri, C.; Lavagna, S.; Novelli, M.; Passuello, G.; Paternoster, G.; Pieracci, M.; Poletti, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.; Testa, A.; Venturelli, L.

    2007-01-01

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm 2 therefore to cover the typical irradiation field used in mammography (18x24 cm 2 ), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma 'La Sapienza', Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%

  18. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    Science.gov (United States)

    Annovazzi, A.; Amendolia, S. R.; Bigongiari, A.; Bisogni, M. G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Colombo, F.; Delogu, P.; Fantacci, M. E.; Gilberti, A.; Lanzieri, C.; Lavagna, S.; Novelli, M.; Passuello, G.; Paternoster, G.; Pieracci, M.; Poletti, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.; Testa, A.; Venturelli, L.

    2007-06-01

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm 2 therefore to cover the typical irradiation field used in mammography (18×24 cm 2), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma "La Sapienza", Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%.

  19. AutoCAD

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1998-01-01

    I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium.......I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium....

  20. Background risk of breast cancer and the association between physical activity and mammographic density.

    Science.gov (United States)

    Trinh, Thang; Eriksson, Mikael; Darabi, Hatef; Bonn, Stephanie E; Brand, Judith S; Cuzick, Jack; Czene, Kamila; Sjölander, Arvid; Bälter, Katarina; Hall, Per

    2015-04-02

    High physical activity has been shown to decrease the risk of breast cancer, potentially by a mechanism that also reduces mammographic density. We tested the hypothesis that the risk of developing breast cancer in the next 10 years according to the Tyrer-Cuzick prediction model influences the association between physical activity and mammographic density. We conducted a population-based cross-sectional study of 38,913 Swedish women aged 40-74 years. Physical activity was assessed using the validated web-questionnaire Active-Q and mammographic density was measured by the fully automated volumetric Volpara method. The 10-year risk of breast cancer was estimated using the Tyrer-Cuzick (TC) prediction model. Linear regression analyses were performed to assess the association between physical activity and volumetric mammographic density and the potential interaction with the TC breast cancer risk. Overall, high physical activity was associated with lower absolute dense volume. As compared to women with the lowest total activity level (association was seen for any type of physical activity among women with association between total activity and absolute dense volume was modified by the TC breast cancer risk (P interaction = 0.05). As anticipated, high physical activity was also associated with lower non-dense volume. No consistent association was found between physical activity and percent dense volume. Our results suggest that physical activity may decrease breast cancer risk through reducing mammographic density, and that the physical activity needed to reduce mammographic density may depend on background risk of breast cancer.

  1. Occupation and mammographic density: A population-based study (DDM-Occup).

    Science.gov (United States)

    García-Pérez, Javier; Pollán, Marina; Pérez-Gómez, Beatriz; González-Sánchez, Mario; Cortés Barragán, Rosa Ana; Maqueda Blasco, Jerónimo; González-Galarzo, María Carmen; Alba, Miguel Ángel; van der Haar, Rudolf; Casas, Silvia; Vicente, Cándida; Medina, Pilar; Ederra, María; Santamariña, Carmen; Moreno, María Pilar; Casanova, Francisco; Pedraz-Pingarrón, Carmen; Moreo, Pilar; Ascunce, Nieves; García, Montse; Salas-Trejo, Dolores; Sánchez-Contador, Carmen; Llobet, Rafael; Lope, Virginia

    2017-11-01

    High mammographic density is one of the main risk factors for breast cancer. Although several occupations have been associated with breast cancer, there are no previous occupational studies exploring the association with mammographic density. Our objective was to identify occupations associated with high mammographic density in Spanish female workers. We conducted a population-based cross-sectional study of occupational determinants of high mammographic density in Spain, based on 1476 women, aged 45-68 years, recruited from seven screening centers within the Spanish Breast Cancer Screening Program network. Reproductive, family, personal, and occupational history data were collected. The latest occupation of each woman was collected and coded according to the 1994 National Classification of Occupations. Mammographic density was assessed from the cranio-caudal mammogram of the left breast using a semi-automated computer-assisted tool. Association between mammographic density and occupation was evaluated by using mixed linear regression models, using log-transformed percentage of mammographic density as dependent variable. Models were adjusted for age, body mass index, menopausal status, parity, smoking, alcohol intake, educational level, type of mammography, first-degree relative with breast cancer, and hormonal replacement therapy use. Screening center and professional reader were included as random effects terms. Mammographic density was higher, although non-statistically significant, among secondary school teachers (e β = 1.41; 95%CI = 0.98-2.03) and nurses (e β = 1.23; 95%CI = 0.96-1.59), whereas workers engaged in the care of people (e β = 0.81; 95%CI = 0.66-1.00) and housewives (e β = 0.87; 95%CI = 0.79-0.95) showed an inverse association with mammographic density. A positive trend for every 5 years working as secondary school teachers was also detected (p-value = 0.035). Nurses and secondary school teachers were the occupations with the highest

  2. Comprehensive Auto CAD

    International Nuclear Information System (INIS)

    Jang, Taekju

    1993-06-01

    This book starts introduction of conception, application system, software for CAD, function of Auto CAD, kinds and function of Auto CAD files. It deals with starting of Auto CAD, dialogue box and Auto CAD interface, utility command, 2D drawing command, check command, control system, dimension, hatching command, layer command, block, 3D drawing, plotting and printing, auto CAD and application of data, supply program of auto CAD, AME and region modeler, EDLIN, script optimization of Auto CAD and composition on demand.

  3. Enhancement and denoising of mammographic images for breast disease detection

    International Nuclear Information System (INIS)

    Yazdani, S.; Yusof, R.; Karimian, A.; Hematian, A.; Yousefi, M.

    2012-01-01

    In these two decades breast cancer is one of the leading cause of death among women. In breast cancer research, Mammographic Image is being assessed as a potential tool for detecting breast disease and investigating response to chemotherapy. In first stage of breast disease discovery, the density measurement of the breast in mammographic images provides very useful information. Because of the importance of the role of mammographic images the need for accurate and robust automated image enhancement techniques is becoming clear. Mammographic images have some disadvantages such as, the high dependence of contrast upon the way the image is acquired, weak distinction in splitting cyst from tumor, intensity non uniformity, the existence of noise, etc. These limitations make problem to detect the typical signs such as masses and microcalcifications. For this reason, denoising and enhancing the quality of mammographic images is very important. The method which is used in this paper is in spatial domain which its input includes high, intermediate and even very low contrast mammographic images based on specialist physician's view, while its output is processed images that show the input images with higher quality, more contrast and more details. In this research, 38 mammographic images have been used. The result of purposed method shows details of abnormal zones and the areas with defects so that specialist could explore these zones more accurately and it could be deemed as an index for cancer diagnosis. In this study, mammographic images are initially converted into digital images and then to increase spatial resolution power, their noise is reduced and consequently their contrast is improved. The results demonstrate effectiveness and efficiency of the proposed methods. (authors)

  4. Changes in mammographic density and breast cancer risk

    NARCIS (Netherlands)

    Lokate, A.J.M.

    2012-01-01

    Breast cancer is the most frequently occurring cancer among women worldwide. One of the most important risk factors for breast cancer is high mammographic density. Mammographic density represents the amount of fibroglandular tissue relative to the fat tissue in the breast. Women with >75% of their

  5. AutoCAD 2014 and AutoCAD LT 2014

    CERN Document Server

    Gladfelter, Donnie

    2013-01-01

    A step-by-step tutorial introduction to AutoCAD As the only book to teach AutoCAD using a continuous tutorial which allows you to follow along sequentially or jump in at any exercise by downloading the drawing files, this Autodesk Official Press book is ideal for the AutoCAD novice. Industry expert and AutoCAD guru Donnie Gladfelter walks you through the powerful features of AutoCAD, provides you with a solid foundation of the basics, and shares the latest industry standards and techniques. The hands-on tutorial project inspired by real-world workflows that runs throughout the book

  6. Comparison of Danish dichotomous and BI-RADS classifications of mammographic density.

    Science.gov (United States)

    Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My; Vejborg, Ilse; Andersen, Zorana Jovanovic

    2014-06-01

    In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. To compare the Danish dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. Of the 120 women, 32 (26.7%) were classified as having fatty and 88 (73.3%) as mixed/dense mammographic density, according to Danish dichotomous classification. According to BI-RADS density classification, 12 (10.0%) women were classified as having predominantly fatty (BI-RADS code 1), 46 (38.3%) as having scattered fibroglandular (BI-RADS code 2), 57 (47.5%) as having heterogeneously dense (BI-RADS 3), and five (4.2%) as having extremely dense (BI-RADS code 4) mammographic density. The inter-rater variability assessed by weighted kappa statistic showed a substantial agreement (0.75). The dichotomous mammographic density classification system utilized in early years of Copenhagen's mammographic screening program (1991-2001) agreed well with the BI-RADS density classification system.

  7. AutoCAD 2008 and AutoCAD LT 2008 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    "Whether you're new to AutoCAD or a veteran, you will undoubtedly find this book to be an excellent resource."-- Abhi Singh, AutoCAD Product Manager, Autodesk, Inc.Here's the book that makes AutoCAD approachableEven the people at Autodesk look to Ellen Finkelstein for AutoCAD training, so who better to teach you about AutoCAD 2008? This comprehensive guide brings veterans up to speed on AutoCAD updates and takes novices from the basics to programming in AutoLISP(r) and VBA. Every feature is covered in a logical order, and with the Quick Start chapter, you'll be creating drawings on your very f

  8. AutoCAD 2015 and AutoCAD LT 2015 bible

    CERN Document Server

    Finkelstein, Ellen

    2014-01-01

    The perfect reference for all AutoCAD users AutoCAD 2015 and AutoCAD LT 2015 Bible is the book you want to have close at hand to answer those day-to-day questions about this industry-leading software. Author and Autodesk University instructor Ellen Finkelstein guides readers through AutoCAD 2015 and AutoCAD LT 2015 with clear, easy-to-understand instruction and hands-on tutorials that allow even total beginners to create a design on their very first day. Although simple and fundamental enough to be used by those new to CAD, the book is so comprehensive that even Autodesk power u

  9. Posterior breast cancer: Mammographic and ultrasonographic features

    Directory of Open Access Journals (Sweden)

    Janković Ana

    2013-01-01

    Full Text Available Background/Aim. Posterior breast cancers are located in the prepectoral region of the breast. Owing to this distinctive anatomical localization, physical examination and mammographic or ultrasonographic evaluation can be difficult. The purpose of the study was to assess possibilities of diagnostic mammography and breast ultrasonography in detection and differentiation of posterior breast cancers. Methods. The study included 40 women with palpable, histopathological confirmed posterior breast cancer. Mammographic and ultrasonographic features were defined according to Breast Imaging Reporting and Data System (BI-RADS lexicon. Results. Based on standard two-view mammography 87.5%, of the cases were classified as BI-RADS 4 and 5 categories, while after additional mammographic views all the cases were defined as BIRADS 4 and 5 categories. Among 96 mammographic descriptors, the most frequent were: spiculated mass (24.0%, architectural distortion (16.7%, clustered microcalcifications (12.6% and focal asymmetric density (12.6%. The differentiation of the spiculated mass was significantly associated with the possibility to visualize the lesion at two-view mammography (p = 0.009, without the association with lesion diameter (p = 0.083 or histopathological type (p = 0.055. Mammographic signs of invasive lobular carcinoma were significantly different from other histopathological types (architectural distortion, p = 0.003; focal asymmetric density, p = 0.019; association of four or five subtle signs of malignancy, p = 0.006. All cancers were detectable by ultrasonography. Mass lesions were found in 82.0% of the cases. Among 153 ultrasonographic descriptors, the most frequent were: irregular mass (15.7%, lobulated mass (7.2%, abnormal color Doppler signals (20.3%, posterior acoustic attenuation (18.3%. Ultrasonographic BI-RADS 4 and 5 categories were defined in 72.5% of the cases, without a significant difference among various histopathological types (p = 0

  10. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    Energy Technology Data Exchange (ETDEWEB)

    Annovazzi, A. [LABEN S.p.A., Vimodrone-Milan (Italy); Amendolia, S.R. [Str. Dip. di Matematica e Fisica dell' Universita, Sassari and Sezione I.N.F.N., Pisa (Italy); Bigongiari, A. [CAEN S.p.A., Viareggio-Lucca (Italy); Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Catarsi, F. [CAEN S.p.A., Viareggio-Lucca (Italy); Cesqui, F. [AMS S.p.A, Rome (Italy); Cetronio, A. [AMS S.p.A, Rome (Italy); Colombo, F. [LABEN S.p.A., Vimodrone-Milan (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Gilberti, A. [LABEN S.p.A., Vimodrone-Milan (Italy); Lanzieri, C. [AMS S.p.A, Rome (Italy); Lavagna, S. [AMS S.p.A, Rome (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Passuello, G. [CAEN S.p.A., Viareggio-Lucca (Italy); Paternoster, G. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Pieracci, M. [CAEN S.p.A., Viareggio-Lucca (Italy); Poletti, M. [LABEN S.p.A., Vimodrone-Milan (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy)]. E-mail: arnaldo.stefanini@pi.infn.it; Testa, A. [CAEN S.p.A., Viareggio-Lucca (Italy); Venturelli, L. [AMS S.p.A, Rome (Italy)

    2007-06-11

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm{sup 2} therefore to cover the typical irradiation field used in mammography (18x24 cm{sup 2}), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma 'La Sapienza', Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%.

  11. Relationship between breast sound speed and mammographic percent density

    Science.gov (United States)

    Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa

    2011-03-01

    Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.

  12. AutoCAD / AutoCAD LT 2014 fundamentals metric

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The objective of AutoCAD/AutoCAD LT 2014 Fundamentals is to enable students to create a basic 2D drawing in the AutoCAD software. Even at this fundamental level, the AutoCAD software is one of the most sophisticated computer applications that you are likely to encounter. Therefore learning to use it can be challenging. To make the process easier and provide flexibility for instructors and students, the training guide is divided into two parts that can be taken independently.

  13. AutoCAD platform customization user interface and beyond

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Make AutoCAD your own with powerful personalization options Options for AutoCAD customization are typically the domain of administrators, but savvy users can perform their own customizations to personalize AutoCAD. Until recently, most users never thought to customize the AutoCAD platform to meet their specific needs, instead leaving it to administrators. If you are an AutoCAD user who wants to ramp up personalization options in your favorite software, AutoCAD Platform Customization: User Interface and Beyond is the perfect resource for you. Author Lee Ambrosius is recognized as a leader in Au

  14. Neural network recognition of mammographic lesions

    International Nuclear Information System (INIS)

    Oldham, W.J.B.; Downes, P.T.; Hunter, V.

    1987-01-01

    A method for recognition of mammographic lesions through the use of neural networks is presented. Neural networks have exhibited the ability to learn the shape andinternal structure of patterns. Digitized mammograms containing circumscribed and stelate lesions were used to train a feedfoward synchronous neural network that self-organizes to stable attractor states. Encoding of data for submission to the network was accomplished by performing a fractal analysis of the digitized image. This results in scale invariant representation of the lesions. Results are discussed

  15. Mammographic and sonographic findings of breast cancer in women younger than 35 years

    International Nuclear Information System (INIS)

    Shaw de Paredes, E.; Marsteller, L.; Eden, B.

    1989-01-01

    Breast carcinoma is uncommon in women under 35 years of age and may be difficult to detect because clinically palpable masses are usually benign, and mammography may be limited by dense parenchyma. The purpose of this work was to evaluate the mammographic findings in young patients with breast cancer and the efficacy of mammography in identifying these lesions. During an 8-year period, 100 breast cancers were diagnosed mammography and sonography were performed in 678% and 19% of patients, respectively; mammography demonstrated the lesion in 90% of cases. Mammographic and sonographic findings are presented

  16. A prototype for a mammographic head and related developments

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L

    2004-02-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni.

  17. A prototype for a mammographic head and related developments

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L.

    2004-01-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni

  18. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    International Nuclear Information System (INIS)

    Lee, Eun Sun; Kim, Se Hyung; Im, Jong Pil; Kim, Sang Gyun; Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn

    2015-01-01

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  19. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Im, Jong Pil; Kim, Sang Gyun [Department of Internal Medicine, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2015-04-15

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  20. Influence of lifestyle factors on mammographic density in postmenopausal women.

    Directory of Open Access Journals (Sweden)

    Judith S Brand

    Full Text Available BACKGROUND: Mammographic density is a strong risk factor for breast cancer. Apart from hormone replacement therapy (HRT, little is known about lifestyle factors that influence breast density. METHODS: We examined the effect of smoking, alcohol and physical activity on mammographic density in a population-based sample of postmenopausal women without breast cancer. Lifestyle factors were assessed by a questionnaire and percentage and area measures of mammographic density were measured using computer-assisted software. General linear models were used to assess the association between lifestyle factors and mammographic density and effect modification by body mass index (BMI and HRT was studied. RESULTS: Overall, alcohol intake was positively associated with percent mammographic density (P trend  = 0.07. This association was modified by HRT use (P interaction  = 0.06: increasing alcohol intake was associated with increasing percent density in current HRT users (P trend  = 0.01 but not in non-current users (P trend  = 0.82. A similar interaction between alcohol and HRT was found for the absolute dense area, with a positive association being present in current HRT users only (P interaction  = 0.04. No differences in mammographic density were observed across categories of smoking and physical activity, neither overall nor in stratified analyses by BMI and HRT use. CONCLUSIONS: Increasing alcohol intake is associated with an increase in mammography density, whereas smoking and physical activity do not seem to influence density. The observed interaction between alcohol and HRT may pose an opportunity for HRT users to lower their mammographic density and breast cancer risk.

  1. Patients Mammographic Dose Survey in a Sample of Slovak Mammography Departments

    International Nuclear Information System (INIS)

    Nikodemova, D.; Horvathova, M.; Gbelcova, L.

    2008-01-01

    Breast cancer is the most frequent cancer and the most frequent cause of cancer induced deaths in Europe. Demographic trends indicate a continuing increase in this substantial public health problem. Systematic early detection, effective diagnostic pathways and high quality services have the ability for lowering the breast cancer mortality rates and for reducing the burden of this disease in the population The widespread use of mammography for early breast cancer detection is highly accepted all over the world. For achievement of a successful national mammography programme in Slovakia, a national QA/QC mammography system was introduced. Coming from alarming values of increase of malignant neoplasm of breast in Slovakia a national mammography audit has been initiated, performed in three runs and working in three phases: assessment of existing status of practice and equipment performance, as well as education and training of radiologists and radiographers of 42 mammography departments; implementation of technical quality programme and patient dose evaluation; clinical image evaluation. Preventive mammography in spite of being a reasonable examination, which represents health benefit for patient, exceed also the health risk. In 1991-1996 mammographic examination created 1.3% from all medical radiodiagnostic expositions made in Slovakia. In 2005 there were realized 241 208 mammographic examinations, 140 798 of them were noticed like preventive examinations. In 2006 the number of all mammographic examinations in Slovakia increased to 271 755 and of them 156 199 were preventive mammographic examinations. In our presentation we tried to establish the average absorbed glandular doses of patients undergoing mammography examinations in 10 selected departments and to compare the obtained results with European diagnostic reference values. The obtained values were used for the proposal of a new national diagnostic reference value for mammography examinations

  2. Calcified trichinosis of pectoral muscle: mammographic appearance

    Energy Technology Data Exchange (ETDEWEB)

    Apesteguia, L. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Murillo, A. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Biurrun, J. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Garcia-Rostan, G. [Servicio Anatomia Patologica, Hospital Virgen del Camino, Pamplona (Spain); Reta, A. [Servicio de Analisis Clinicos, Hospital Virgen del Camino, Pamplona (Spain); Dominguez, F. [Servicio Cirugia, Hospital Virgen del Camino, Pamplona (Spain)

    1995-12-31

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients` diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  3. Calcified trichinosis of pectoral muscle: mammographic appearance

    International Nuclear Information System (INIS)

    Apesteguia, L.; Murillo, A.; Biurrun, J.; Garcia-Rostan, G.; Reta, A.; Dominguez, F.

    1995-01-01

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients' diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  4. AutoCAD 2012 and AutoCAD LT 2012 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    The latest version of this perennial favorite, in-depth, reference-tutorial This top-selling book has been updated by AutoCAD guru and author Ellen Finkelstein to provide you with the very latest coverage of both AutoCAD 2012 and AutoCAD LT 2012. It begins with a Quick Start tutorial, so you start creating right away. From there, the book covers so much in-depth material on AutoCAD that it is said that even Autodesk employees keep this comprehensive book at their desks. A DVD is included that features before-and-after drawings of all the tutorials and plenty of great examples from AutoCAD prof

  5. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    Science.gov (United States)

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  6. Mammographic Findings after Intraoperative Radiotherapy of the Breast

    International Nuclear Information System (INIS)

    Rivera, R.; Holmes, D.R.; Smith-Bronstein, V.S.; Villegas-Mendez, S.; Rayhanabad, J.; Sheth, P.; Rashtian, A.

    2012-01-01

    Intraoperative Radiotherapy (IORT) is a form of accelerated partial breast radiation that has been shown to be equivalent to conventional whole breast external beam radiotherapy (EBRT) in terms of local cancer control. However, questions have been raised about the potential of f IORT to produce breast parenchymal changes that could interfere with mammographic surveillance of cancer recurrence. The purpose of this study was to identify, quantify, and compare the mammographic findings of patients who received IORT and EBRT in a prospective, randomized controlled clinical trial of women with early stage invasive breast cancer undergoing breast conserving therapy between July 2005 and December 2009. Treatment groups were compared with regard to the 1, 2 and 4-year incidence of 6 post-operative mammographic findings: architectural distortion, skin thickening, skin retraction, calcifications, fat necrosis, and mass density. Blinded review of 90 sets of mammograms of 15 IORT and 16 EBRT patients demonstrated a higher incidence of fat necrosis among IORT recipients at years 1, 2, and 4. However, none of the subjects were judged to have suspicious mammogram findings and fat necrosis did not interfere with mammographic interpretation.

  7. The Mammographic Head Demonstrator Developed in the Framework of the “IMI” Project:. First Imaging Tests Results

    Science.gov (United States)

    Bisogni, Maria Giuseppina

    2006-04-01

    In this paper we report on the performances and the first imaging test results of a digital mammographic demonstrator based on GaAs pixel detectors. The heart of this prototype is the X-ray detection unit, which is a GaAs pixel sensor read-out by the PCC/MEDIPIXI circuit. Since the active area of the sensor is 1 cm2, 18 detectors have been organized in two staggered rows of nine chips each. To cover the typical mammographic format (18 × 24 cm2) a linear scanning is performed by means of a stepper motor. The system is integrated in mammographic equipment comprehending the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies in collaboration with the universities of Ferrara, Roma “La Sapienza”, Pisa and the INFN.

  8. Mammographic follow-up after conservation therapy for breast cancer

    International Nuclear Information System (INIS)

    Gu Yajia; Xiao Qin; Zheng Xiaojing; Wu Jiong; Chen Jiayi; Gu Rongfeng; Feng Xiaoyuan

    2006-01-01

    Objective: To recognize the mammographic changes after conservation therapy for breast carcinoma. Methods: A total of 139 follow-up mammographic examinations in 85 cases were studied during the period between 1999 and 2004. Mammography was performed at intervals of 6 months for the first 2 years, then annually. Attention was paid to mammographic change patterns of conservation therapy for breast carcinoma, including breast edema, skin thickening, architectural disturbance, asymmetric density, architectural distortion retraction, and calcifications. SPSS version 11.0 for windows was used to perform all statistical tests. Kruskal-Wallis H test was used for calculating the overall statistical differences between difference periods. Categorical data were expressed as percentages and analyzed by using the X 2 test. The age of the patients ranged from 25 to 63 years (mediate, 44 years old). The time of follow-up observation ranged from 1 week to 72 months. Results: Two cases were normal on mammograms. High proportion of abnormal mammography was seen in the period of 12 month (40.3%, 56/139) and 24 month (21.6%, 30/139), respectively. Various findings appeared in various periods and the difference was statistically significant(X 2 =30.998, v=6, P=0.001). Mild edema appeared in the first 3 years. Moderately severe or marked breast edema may be present between 6 months to 12 months, then slowly resolved. The appearance and disappearance of skin thickening were similar to the process of breast edema. The changes of architectural disturbance did not correlate with time (X 2 =8.634, P>0.05), but on sequential mammograms for same patient, the extent of architectural disturbance relieved over time (17/19). Asymmetric density was found in only 5 patients, and disappeared in later period of follow-up in 3. Architectural distortion retraction got more and more obvious with time, and kept stable after certain period of time. Calcifications were shown in 2 patients, including 1

  9. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  10. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    International Nuclear Information System (INIS)

    Benzakoun, Joseph; Bommart, Sébastien; Coste, Joël; Chassagnon, Guillaume; Lederlin, Mathieu; Boussouar, Samia

    2016-01-01

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  11. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    Energy Technology Data Exchange (ETDEWEB)

    Benzakoun, Joseph, E-mail: benzakoun.joseph@gmail.com [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Bommart, Sébastien, E-mail: s-bommart@chu-montpellier.fr [CHU de Montpellier, 191 avenue du Doyen Gaston Giraud, 34000 Montpellier (France); INSERM U 1046, 371 avenue du Doyen G. Giraud, 34000 Montpellier (France); Coste, Joël, E-mail: joel.coste@htd.aphp.fr [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Chassagnon, Guillaume, E-mail: gchassagnon@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Cochin, Radiologie, 27 rue du Faubourg Saint Jacques, 75014 Paris (France); Lederlin, Mathieu, E-mail: mathieu.lederlin@chu-rennes.fr [CHU de Rennes, Radiologie, 2 Rue Henri le Guilloux, 35000 Rennes (France); Université de Rennes 1, 9 Rue Jean Macé, 35000 Rennes (France); Boussouar, Samia, E-mail: samiaboussouar@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Européen Georges Pompidou, 20 Rue Leblanc, 75015 Paris (France); and others

    2016-10-15

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  12. Indications and guidelines for mammographic examinations

    International Nuclear Information System (INIS)

    Kalisher, L.; Schaffer, D.

    1977-01-01

    The value of mammography in evaluating the asymptomatic patient has been clearly demonstrated by the HIP program, as well as the National Cancer Institute's breast demonstration projects. A one-third reduction in mortality from breast cancer in mammographically screened women has been substantiated. Nonetheless, questions concerning the long-term effects of repeated radiation exposure associated with mammography have been raised, and for this reason judicious selection of women is urged. In general, women who are asymptomatic or at high risk for breast carcinoma should be evaluated with a planned regimen. Mammographic guidelines and recommendations for attaining the greatest benefit at the lowest possible risk are suggested

  13. Ultrasonographic and mammographic findings of gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Kyung; Choi, Gyo Chang; Hong, Hyun Sook; Kim, Young Beom; Lee, Hae Kyung; Kwon, Kui Hyang [Soonchunhyang Univ. College of Medicine, Asan (Korea, Republic of)

    1996-11-01

    The purpose of this study is to evaluate the radiologic features and clinical utility of ultrasonography and mammography in cases of gynecomastia. This study involved 40 men in whom gynecomastia had been pathologically diagnosed by surgical incision. In 21 cases, a retrospective analysis of ultrasonographic and mammographic findings was performed. Causative factors of gynecomastia among the 40 pathologically-proven cases were idiopathic or pubertal in 33 cases, related to male hormone deficiency in three cases and to chronic liver disease in four. Bi-lateral involvement was seen in 14 cases, and unilateral involvement in 26;among unilateral cases, right side was involved in 10 cases, and the left side in 16. Mammographically, a subareolar discoid lesion was present in 12 cases, diffuse increased breast density was seen in five cases and dendritic marginated subareolar lesion without microcalcification in one. Ultrasonographically, a round smooth marginated low echogenic lesion in the subareolar region was seen in five cases, a diffuse hyperechogenic pattern without definite mass in two cases and an ill defined low echogenic lesion in one. The male breast is small, so in cases of gynecomastia, ultrasonography is an effective diagnostic modality. Mamography will, however, be helpful in the detection of microcalcification in cases of gynecomastia seen on sonography.

  14. Structured reporting platform improves CAD-RADS assessment.

    Science.gov (United States)

    Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; Jermendy, Ádám L; Károlyi, Mihály; Panajotu, Alexisz; Bagyura, Zsolt; Vecsey-Nagy, Milán; Cury, Ricardo C; Leipsic, Jonathon A; Merkely, Béla; Maurovich-Horvat, Pál

    2017-11-01

    Structured reporting in cardiac imaging is strongly encouraged to improve quality through consistency. The Coronary Artery Disease - Reporting and Data System (CAD-RADS) was recently introduced to facilitate interdisciplinary communication of coronary CT angiography (CTA) results. We aimed to assess the agreement between manual and automated CAD-RADS classification using a structured reporting platform. Five readers prospectively interpreted 500 coronary CT angiographies using a structured reporting platform that automatically calculates the CAD-RADS score based on stenosis and plaque parameters manually entered by the reader. In addition, all readers manually assessed CAD-RADS blinded to the automatically derived results, which was used as the reference standard. We evaluated factors influencing reader performance including CAD-RADS training, clinical load, time of the day and level of expertise. Total agreement between manual and automated classification was 80.2%. Agreement in stenosis categories was 86.7%, whereas the agreement in modifiers was 95.8% for "N", 96.8% for "S", 95.6% for "V" and 99.4% for "G". Agreement for V improved after CAD-RADS training (p = 0.047). Time of the day and clinical load did not influence reader performance (p > 0.05 both). Less experienced readers had a higher total agreement as compared to more experienced readers (87.0% vs 78.0%, respectively; p = 0.011). Even though automated CAD-RADS classification uses data filled in by the readers, it outperforms manual classification by preventing human errors. Structured reporting platforms with automated calculation of the CAD-RADS score might improve data quality and support standardization of clinical decision making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Comparison of Danish dichotomous and BI-RADS classifications of mammographic density

    DEFF Research Database (Denmark)

    Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My

    2014-01-01

    BACKGROUND: In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. PURPOSE: To compare the Danish...... dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. MATERIAL AND METHODS: The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive......, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. RESULTS...

  16. Bomb CAD

    International Nuclear Information System (INIS)

    Massa, R.J.; Howard, J.W.

    1989-01-01

    This paper describes BombCAD a computer-aided analysis technique for assessing the damage to diverse structures which results from specific high explosive detonations within or near the structure. BombCAD analyzes the vulnerability of specific facilities to bomb attach, and evaluates siting, screening and hardening/softening aspects of comprehensive bomb defense programs. The paper describes BombCAD's architectural models of specific structures, computations of blastwave effects and the paradigms which relate blast wave effects to both structural damage and human injury. The use of BombCAD in bomb attack vulnerability assessment, facility design, bomb threat response planning and post-incident analyses is described and field examples are presented

  17. The implementation of an AR (augmented reality) approach to support mammographic interpretation training: an initial feasibility study

    Science.gov (United States)

    Tang, Qiang; Chen, Yan; Gale, Alastair G.

    2017-03-01

    Appropriate feedback plays an important role in optimising mammographic interpretation training whilst also ensuring good interpretation performance. The traditional keyboard, mouse and workstation technical approach has a critical limitation in providing supplementary image-related information and providing complex feedback in real time. Augmented Reality (AR) provides a possible superior approach in this situation, as feedback can be provided directly overlaying the displayed mammographic images so making a generic approach which can also be vendor neutral. In this study, radiological feedback was dynamically remapped virtually into the real world, using perspective transformation, in order to provide a richer user experience in mammographic interpretation training. This is an initial attempt of an AR approach to dynamically superimpose pre-defined feedback information of a DICOM image on top of a radiologist's view, whilst the radiologist is examining images on a clinical workstation. The study demonstrates the feasibility of the approach, although there are limitations on interactive operations which are due to the hardware used. The results of this fully functional approach provide appropriate feedback/image correspondence in a simulated mammographic interpretation environment. Thus, it is argued that employing AR is a feasible way to provide rich feedback in the delivery of mammographic interpretation training.

  18. Study of quality perception in medical images based on comparison of contrast enhancement techniques in mammographic images

    Science.gov (United States)

    Matheus, B.; Verçosa, L. B.; Barufaldi, B.; Schiabel, H.

    2014-03-01

    With the absolute prevalence of digital images in mammography several new tools became available for radiologist; such as CAD schemes, digital zoom and contrast alteration. This work focuses in contrast variation and how the radiologist reacts to these changes when asked to evaluated image quality. Three contrast enhancing techniques were used in this study: conventional equalization, CCB Correction [1] - a digitization correction - and value subtraction. A set of 100 images was used in tests from some available online mammographic databases. The tests consisted of the presentation of all four versions of an image (original plus the three contrast enhanced images) to the specialist, requested to rank each one from the best up to worst quality for diagnosis. Analysis of results has demonstrated that CCB Correction [1] produced better images in almost all cases. Equalization, which mathematically produces a better contrast, was considered the worst for mammography image quality enhancement in the majority of cases (69.7%). The value subtraction procedure produced images considered better than the original in 84% of cases. Tests indicate that, for the radiologist's perception, it seems more important to guaranty full visualization of nuances than a high contrast image. Another result observed is that the "ideal" scanner curve does not yield the best result for a mammographic image. The important contrast range is the middle of the histogram, where nodules and masses need to be seen and clearly distinguished.

  19. Ultrasonographic Findings of Mammographic Architectural Distortion

    International Nuclear Information System (INIS)

    Ma, Jeong Hyun; Kang, Bong Joo; Cha, Eun Suk; Hwangbo, Seol; Kim, Hyeon Sook; Park, Chang Suk; Kim, Sung Hun; Choi, Jae Jeong; Chung, Yong An

    2008-01-01

    To review the sonographic findings of various diseases showing architectural distortion depicted under mammography. We collected and reviewed architectural distortions observed under mammography at our health institution between 1 March 2004, and 28 February 2007. We collected 23 cases of sonographically-detected mammographic architectural distortions that confirmed lesions after surgical resection. The sonographic findings of mammographic architectural distortion were analyzed by use of the BI-RADS lexicon for shape, margin, lesion boundary, echo pattern, posterior acoustic feature and orientation. There were variable diseases that showed architectural distortion depicted under mammography. Fibrocystic disease was the most common presentation (n = 6), followed by adenosis (n = 2), stromal fibrosis (n = 2), radial scar (n = 3), usual ductal hyperplasia (n = 1), atypical ductal hyperplasia (n = 1) and mild fibrosis with microcalcification (n = 1). Malignant lesions such as ductal carcinoma in situ (DCIS) (n = 2), lobular carcinoma in situ (LCIS) (n = 2), invasive ductal carcinoma (n = 2) and invasive lobular carcinoma (n = 1) were observed. As observed by sonography, shape was divided as irregular (n = 22) and round (n = 1). Margin was divided as circumscribed (n = 1), indistinct (n = 7), angular (n = 1), microlobulated (n = 1) and sipculated (n = 13). Lesion boundary was divided as abrupt interface (n = 11) and echogenic halo (n = 12). Echo pattern was divided as hypoechoic (n = 20), anechoic (n = 1), hyperechoic (n = 1) and isoechoic (n = 1). Posterior acoustic feature was divided as posterior acoustic feature (n = 7), posterior acoustic shadow (n = 15) and complex posterior acoustic feature (n = 1). Orientation was divided as parallel (n = 12) and not parallel (n = 11). There were no differential sonographic findings between benign and malignant lesions. This study presented various sonographic findings of mammographic architectural distortion and that it is

  20. State supervision of SONS in the mammographic departments

    International Nuclear Information System (INIS)

    Jursikova, E.; Kodl, O.

    2008-01-01

    State Office for Nuclear Safety has been performed the state supervision over radiation protection at all mammographic centres in the Czech Republic. Inspections are carried out on the basis of requirements of: Act No. 18/1997 Coll., Atomic Act, subsequently amended; Act No. 552/1991 Coll., Supervision Act, subsequently amended; Decree No. 307 /2002 Coll., On radiation protection, as amended by Decree No. 499/2005 Coll. 137 mammography X-ray units have been used actively by 108 independent licensees since 1 September 2008. The mammography screening program started in September 2002. The screening program was carried out at 59 working places last year and already at 66 workplaces with accreditation from 1 up to 3 years this year. The activity of the centres is monitored and inspected continuously (not only by SONS). Inspections at 35 workplaces were carried out last year .The doses are significantly below guidance levels at major part of working places. Most of detected defects were eliminated after inspections. The quality of mammographic workplaces in the Czech Republic has been gradually increased and improved. (authors)

  1. Mammographic Screening of Women Attending a Reference Service Center in Southern Brazil.

    Science.gov (United States)

    Romeiro Lopes, Tiara Cristina; Franca Gravena, Angela Andreia; Demitto, Marcela de Oliveira; Brischiliari, Sheila Cristina Rocha; Borghesan, Deise Helena Pelloso; Dell Agnolo, Catia Millene; Carvalho, Maria Dalva de Barros; Pelloso, Sandra Marisa

    2016-01-01

    To investigate the prevalence of and factors associated with performance of annual mammography by women above 40 years of age. This cross-sectional retrospective study was conducted at an oncology reference service in Southern Brazil from October 2013 to October 2014 with 525 women aged 40 years or older. The prevalence of annual mammography was 54.1%; annual mammographic screening was performed for women without private medical insurance, who were under hormone replacement therapy and who had used contraception in the past. An association was found between non-performance of breast clinical and self-examination and non-performance of mammographic screening. Use of mammography for breast cancer screening in the public health care setting proved to be accessible; nevertheless, the proportion of screened women was low, and they exhibited poor adherence to the basic measures of care recommended for breast assessment. Thus, control of breast cancer requires implementing actions targeting the population most vulnerable to non-adherence to screening in addition to continuously monitoring and assessing that population to reduce the prevalence of this disease.

  2. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  3. Mammographic screening practices among Chinese-Australian women.

    Science.gov (United States)

    Kwok, Cannas; Fethney, Judith; White, Kate

    2012-03-01

    To report mammographic screening practice among Chinese-Australian women, and to examine the relationship between demographic characteristics, acculturation factors (English proficiency and length of stay in Australia), cultural beliefs, and having a mammogram as recommended. Cross-sectional and descriptive. The study was conducted in 2009 in Sydney, Australia. Of 988 Chinese-Australian women over 18 years of age invited to participate in the study, 785 (79%) completed and returned the questionnaire. Of these women, 320 (40.8%) were in the target age range of 50 to 69 years. The Chinese Breast Cancer Screening Beliefs Questionnaire (CBCSB) was used as a data collection instrument. Analysis included descriptive statistics, bivariate analysis using chi-square and t tests, and logistic regression. Of the 320 women in the targeted age range of 50 to 69 years, 238 (74.4%) had a mammogram as recommended biannually. Being married-de facto, in the 60 to 69 age group, and speaking Cantonese at home were positively associated with women's mammographic screening practice. However, no statistically significant differences in acculturation factors and having a mammogram as recommended were found. In terms of CBCSB score, women who had mammograms as recommended had more positive attitudes toward health checkups and perceived fewer barriers to mammographic screening. Effort should be focused on specific subgroups of Chinese-Australian women in order to fully understand the barriers involved in participating in mammographic screening. Nurses can use the findings from the present study to design culturally sensitive breast cancer screening programs to encourage women's participation in mammography. © 2011 Sigma Theta Tau International.

  4. Mammographic density in asymptomatic menopausal women: correlation with clinical and sonographic findings

    Directory of Open Access Journals (Sweden)

    Beatriz Regina Alvares

    2012-06-01

    Full Text Available OBJECTIVE: To evaluate mammographic breast density in asymptomatic menopausal women in correlation with clinical and sonographic findings. MATERIALS AND METHODS: Mammograms and clinical and sonographic findings of 238 asymptomatic patients were retrospectively reviewed in the period from February/2022 to June/2006. The following variables were analyzed: mammographic density patterns, sonographic findings, patients' age, parity, body mass index and use of hormone replacement therapy. RESULTS: Age, parity and body mass index showed a negative correlation with breast density pattern, while use of hormone replacement therapy showed a positive correlation. Supplementary breast ultrasonography was performed in 103 (43.2% patients. Alterations which could not be visualized at mammography were found in 34 (33% of them, most frequently in women with breast density patterns 3 and 4. CONCLUSION: The authors concluded that breast density patterns were influenced by age, parity, body mass index and time of hormone replacement therapy. Despite not having found any malignant abnormality in the studied cases, the authors have observed a predominance of benign sonographic abnormalities in women with high breast density patterns and without mammographic abnormalities, proving the relevance of supplementary ultrasonography to identify breast lesions in such patients.

  5. Mammographic breast density patterns among a group of women in ...

    African Journals Online (AJOL)

    Introduction: Mammographic breast density is a measure of parenchymal breast patterns on film and in part a marker of cumulative exposure to oestrogen. The risk of breast cancer for women with increased density is up to six fold more than in women with less dense tissues. The pattern of mammographic breast density ...

  6. Collaborating with Mammographers to Address Their Work-Related Musculoskeletal Discomfort

    Science.gov (United States)

    Sommerich, Carolyn M.; Lavender, Steven A.; Evans, Kevin D.; Sanders, Elizabeth; Joines, Sharon; Lamar, Sabrina; Umar, Radin Zaid Radin; Yen, Wei-Ting; Park, SangHyun

    2017-01-01

    Mammographers are an understudied group of healthcare workers, yet the prevalence of musculoskeletal (MSK) symptoms in mammographers appears to be elevated, similar to many occupations in healthcare. In this study, we used a participatory approach to identify needs and opportunities for developing interventions to reduce mammographers’ exposures to risk factors that lead to development of MSK symptoms. In this paper, we present a number of those needs and several intervention concepts along with evaluations of those concepts from experienced mammographers. We include findings from a preliminary field test of a novel intervention concept to reduce the need to adopt awkward postures while positioning patients for a screening or diagnostic mammogram. PMID:26794257

  7. A new approach to develop computer-aided detection schemes of digital mammograms

    Science.gov (United States)

    Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin

    2015-06-01

    The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779   ±   0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.

  8. Immersive CAD

    Energy Technology Data Exchange (ETDEWEB)

    Ames, A.L.

    1999-02-01

    This paper documents development of a capability for performing shape-changing editing operations on solid model representations in an immersive environment. The capability includes part- and assembly-level operations, with part modeling supporting topology-invariant and topology-changing modifications. A discussion of various design considerations in developing an immersive capability is included, along with discussion of a prototype implementation we have developed and explored. The project investigated approaches to providing both topology-invariant and topology-changing editing. A prototype environment was developed to test the approaches and determine the usefulness of immersive editing. The prototype showed exciting potential in redefining the CAD interface. It is fun to use. Editing is much faster and friendlier than traditional feature-based CAD software. The prototype algorithms did not reliably provide a sufficient frame rate for complex geometries, but has provided the necessary roadmap for development of a production capability.

  9. Mammographic Breast Density in Malaysian Women with Breast Cancer

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung

    2016-01-01

    The objective of this study was to examine the mammographic breast density of women with breast cancer detected on voluntary mammographic screening at two selected screening centers in Malaysia. This was a retrospective study of Full-Field Digital Mammography (FFDM) images of 150 Malaysian women with biopsy-proven breast cancer. The study population comprised 73 Malays (37.7 %), 59 Chinese (39.3 %) and 18 Indians (12.0 %). The Tabar breast density Patterns (I - V) were used to evaluate mammographic breast density. Data were analyzed using descriptive statistics. The results were compared with findings from a similar study on a group of 668 women who did not have breast cancer. The results showed that 44.7 % of the study population had dense breasts (Patterns IV and V), 14.7 % had predominantly fatty breasts (Patterns II and III) while 40.7 % had Pattern I. The proportion of study population with dense breasts decreased with age. In conclusion, the proportion of women with dense breasts decreased with age. Majority of the women with cancer (44.7 %) had dense breasts of Tabar Patterns IV and V, which has been associated with increased risk of breast cancer detected by voluntary mammographic screening. The results support the notion that increased breast density is a risk factor of breast cancer. (author)

  10. CAD for CT colonography: toward a preparation-independent scheme

    International Nuclear Information System (INIS)

    Naeppi, J.

    2007-01-01

    Computer-aided detection (CAD) systems can be used to automatically detect and display the locations of polyps and masses in computed tomographic colonography (CTC) data for assisting radiologists' image interpretation. Rapid technical advancements over the last few years have established a fundamental CAD scheme for CTC that includes the steps of colon extraction, polyp detection, and false-positive (FP) reduction. Several CAD prototype systems have demonstrated clinically acceptable high polyp detection sensitivity with relatively few FP detections in cathartic CTC, and observer studies have demonstrated the potential benefit of such systems in improving the accuracy and consistency of radiologists' detection performance. Some CAD prototype systems have also demonstrated promising performance in reduced cathartic and non-cathartic CTC. Recent advancements suggest that CAD systems can soon be expected to provide a preparation-independent scheme that can yield consistently high detection sensitivity with moderately low FP rate not only with cathartic CTC protocols but over a wide range of cathartic, reduced cathartic, and non-cathartic CTC protocols. (orig.)

  11. The impact of mammographic screening on breast cancer mortality in Europe

    DEFF Research Database (Denmark)

    Broeders, Mireille; Moss, Sue; Nyström, Lennarth

    2012-01-01

    To assess the impact of population-based mammographic screening on breast cancer mortality in Europe, considering different methodologies and limitations of the data.......To assess the impact of population-based mammographic screening on breast cancer mortality in Europe, considering different methodologies and limitations of the data....

  12. Progress of computer-aided detection/diagnosis (CAD in dentistryCAD in dentistry

    Directory of Open Access Journals (Sweden)

    Akitoshi Katsumata

    2014-08-01

    CAD is also useful in the detection and evaluation of dental and maxillofacial lesions. Identifying alveolar bone resorption due to periodontitis and radiolucent jaw lesions (such as radicular and dentigerous cysts are important goals for CAD. CAD can be applied not only to panoramic radiography but also to dental cone-beam computed tomography (CBCT images. Linking of CAD and teleradiology will be an important issue.

  13. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Obenauer, S.; Hermann, K.P.

    2012-01-01

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  14. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, Patricia, E-mail: p.mayo@titaniast.co [Titania Servicios Tecnologicos S.L., Grupo Dominguis, Apartado 46015, Valencia (Spain); Rodenas, Francisco [Departamento de Matematica Aplicada, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain); Manuel Campayo, Juan [Hospital Clinico Universitario de Valencia, Avda. Blasco Ibanez, Apartado 46017, Valencia (Spain); Verdu, Gumersido [Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain)

    2010-07-21

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  15. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    International Nuclear Information System (INIS)

    Mayo, Patricia; Rodenas, Francisco; Manuel Campayo, Juan; Verdu, Gumersido

    2010-01-01

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  16. AutoCAD 2015 and AutoCAD LT 2015 essentials

    CERN Document Server

    Onstott, Scott

    2014-01-01

    Step-by-step instructions for the AutoCAD fundamentals AutoCAD 2015 Essentials contains 400 pages of full-color, comprehensive instruction on the world's top drafting and architecture software. This 2015 edition features architectural, manufacturing, and landscape architecture examples. And like previous editions, the detailed guide introduces core concepts using interactive tutorials and open-ended projects, which can be completed in any order, thanks to downloadable data sets (an especially useful feature for students and professionals studying for Autodesk AutoCAD certification). Unlike man

  17. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  18. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  19. Preparation of CAD infrastructure for ITER procurement packages allocated to Korea

    International Nuclear Information System (INIS)

    Kim, G.H.; Hwang, H.S.; Choi, J.H.; Lee, H.G.; Thomas, E.; Redon, F.; Wilhelm, B.

    2013-01-01

    Highlights: ► It is necessary to use the same CAD platform between project partners for efficient design collaboration. ► Several unexpected problems were found during preparation of the CAD infrastructure. ► The problems have resulted in a waste of time and cost. ► The approach using the same configurations is effective to avoid IT-related problems. ► The design activities are steadily being performed on the prepared ITER CAD platform. -- Abstract: It is necessary to use the same CAD platform for standardization and efficient design collaboration between project partners. ITER has selected CATIA with ENOVIA as the primary CAD and integration tool. During the preparation of the CAD infrastructure, there were several difficulties with respect to information technology (IT). ITER design is classified as mechanical and plant. The procurement arrangement is divided into three types; functional specification, detailed design, and build to print. Therefore, it is important to prepare the suitable prerequisites according to the design type, and to comply with CAD methodologies to avoid trial and error. This paper presents how to overcome the difficulties and how to perform the CAD activities for ITER Korea procurement packages including important matters on a CAD infrastructure in a big project

  20. Computer-aided detection system applied to full-field digital mammograms

    International Nuclear Information System (INIS)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella; Munoz Cacho, Pedro; Hoffmeister, Jeffrey W.

    2010-01-01

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  1. Computer-aided detection system applied to full-field digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella (Dept. of Radiology, Univ. Marques of Valdecilla Hospital, Santander (Spain)), e-mail: avegab@telefonica.net; Munoz Cacho, Pedro (Dept. of Statistics, Univ. Marques of Valdecilla Hospital, Santander (Spain)); Hoffmeister, Jeffrey W. (iCAD, Inc., Nashua, NH (United States))

    2010-12-15

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  2. MS AutoCad

    DEFF Research Database (Denmark)

    Andersen, Michael Rye; Heinicke, Hugo

    1996-01-01

    Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund for praktiskprojekter......Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund...

  3. COMBINED MAMMOGRAPHIC AND SONOGRAPHIC EVALUATION OF PALPABLE BREAST MASSES

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-10-01

    Full Text Available BACKGROUND Breast diseases are common in females. In developing countries like India, females are unaware of breast pathologies hence they are detected usually in advanced stages. We have studied 100 patients of palpable breast masses presenting to our department and evaluate the role of combined mammographic and sonographic imaging in patients with palpable abnormalities of the breast, which help in decision making by clinician as to lesion go for biopsy or follow up. MATERIALS AND METHODS The study was conducted at Department of Radiodiagnosis J. L.N. Medical College & Associated Groups of Hospitals, Ajmer. We included women equal to or more than 30 years referred to this centre with palpable abnormalities of breast during a period from March 2015 to August 2016. All these women underwent a combined mammographic and sonographic evaluation of breast. RESULTS 50 (50% of the 100 palpable abnormalities had benign assessment, 30 (60% of the benign lesions were visible both on mammography and sonography; 18 (36% of the 50 benign lesions were mammographically occult and identified at sonographic evaluation. 2 lesion was sonographically occult (4% and visualized on mammography. In 14 (14% of the 100 cases, imaging evaluation resulted in a suspicious assessment and all these lesions underwent biopsy and 4 were diagnosed as having malignancy. 36(36% of the 100 palpable abnormalities had negative imaging assessment finding: of these 14 patients underwent biopsy and all had benign findings. The sensitivity and negative predictive value for combined mammographic and sonographic assessment were 100%; the specificity was 78.26%. CONCLUSION Combined use of mammography and sonography plays an important role in the management of palpable breast lesions. It characterizes the palpable mass lesion, avoids unnecessary interventions in which imaging findings are unequivocally benign. Negative findings on combined mammographic and sonographic imaging have very high

  4. Analysis of mammographic findings of breast cancer

    International Nuclear Information System (INIS)

    Park, Hyun Joo; Han, Heon; Yang, Dal Mo; Chung, Hyo Sun; Kim, Jee Eun; Kim, Young Chae

    1995-01-01

    This study is to describe authors' experience on mammographic findings of breast cancer and to know if there is difference between 35 years of age or younger and older groups. Mammograms of 72 patients with breast cancer detected from January, 1991 to December, 1993 were retrospectively analysed. Mammographic findings were classified into mass only, mass with microcalcifications, microcalcifications only and others. Marginal characteristics of mass were classified into spiculated, poorly marginated and well marginated. Shape of microcalcifications were classified into casting, granular and mixed types. These findings were compared between 35 years of age or younger and older groups. Mammogram showed mass only in 33 patients (46%), mass with microcalcifications in 26 patients (36%), microcalcifications only in seven (10%) and other findings in six (8%). Other findings were architectural distortion, asymmetric high density and incidental breast carcinoma from paraffinoma in one patient respectively, and dense breast in three patients. The margins of the breast mass were spiculated in ten (17%). poorly marginated in 30 (51%), well-marginated in 19 (32%). Shape of microcalcifications were casting type in 13 (40%). granular in 14 (42%) and mixed in six (18%) cases. 3 patients had dense breast with which mammography did not demonstrate the lesion. 3 patients without mammographically demonstrable lesions due to dense breasts were under 35 years in age, and there was statistically significant difference between the two groups (ρ -value < 0.05). Microcalcifications only was more common findings in 35 years of age or younger. The most important mammographic findings of breast cancer were mass and microcalcifications. Architectural distortion and asymmetric high density were additional findings. In 35 years of age or younger, microcalcifications only was an important finding because mass lesions are frequently masked by dense breast. Thus other imaging modalities, such as

  5. AutoCAD 2014 for dummies

    CERN Document Server

    Fane, Bill

    2013-01-01

    Find your way around AutoCAD 2014 with this full-color, For Dummies guide!Put away that pencil and paper and start putting the power of AutoCAD 2014 to work in your CAD projects and designs. From setting up your drawing environment to using text, dimensions, hatching, and more, this guide walks you through AutoCAD basics and provides you with a solid understanding of the latest CAD tools and techniques. You'll also benefit from the full-color illustrations that mirror exactly what you'll see on your AutoCAD 2014 screen and highlight the importance of AutoCAD's Mode

  6. Learning Auto CAD 2004

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-15

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  7. Learning Auto CAD 2004

    International Nuclear Information System (INIS)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-01

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  8. Performance assessments of vertically aligned carbon nanotubes multi-electrode arrays using Cath.a-differentiated (CAD) cells

    Science.gov (United States)

    Jeong, Du Won; Jung, Jongjin; Kim, Gook Hwa; Yang, Cheol-Soo; Kim, Ju Jin; Jung, Sang Don; Lee, Jeong-O.

    2015-08-01

    In this work, Cath.a-differentiated (CAD) cells were used in place of primary neuronal cells to assess the performance of vertically aligned carbon nanotubes (VACNTs) multi-electrode arrays (MEA). To fabricate high-performance MEA, VACNTs were directly grown on graphene/Pt electrodes via plasma enhanced chemical deposition technique. Here, graphene served as an intermediate layer lowering contact resistance between VACNTs and Pt electrode. In order to lower the electrode impedance and to enhance the cell adhesion, VACNTs-MEAs were treated with UV-ozone for 20 min. Impedance of VACNTs electrode at 1 kHz frequency exhibits a reasonable value (110 kΩ) for extracellular signal recording, and the signal to noise ratio the is good enough to measure low signal amplitude (15.7). Spontaneous firing events from CAD cells were successfully measured with VACNTs MEAs that were also found to be surprisingly robust toward the biological interactions.

  9. Performance assessments of vertically aligned carbon nanotubes multi-electrode arrays using Cath.a-differentiated (CAD) cells

    International Nuclear Information System (INIS)

    Jeong, Du Won; Jin Kim, Ju; Jung, Jongjin; Yang, Cheol-Soo; Lee, Jeong-O; Hwa Kim, Gook; Don Jung, Sang

    2015-01-01

    In this work, Cath.a-differentiated (CAD) cells were used in place of primary neuronal cells to assess the performance of vertically aligned carbon nanotubes (VACNTs) multi-electrode arrays (MEA). To fabricate high-performance MEA, VACNTs were directly grown on graphene/Pt electrodes via plasma enhanced chemical deposition technique. Here, graphene served as an intermediate layer lowering contact resistance between VACNTs and Pt electrode. In order to lower the electrode impedance and to enhance the cell adhesion, VACNTs-MEAs were treated with UV–ozone for 20 min. Impedance of VACNTs electrode at 1 kHz frequency exhibits a reasonable value (110 kΩ) for extracellular signal recording, and the signal to noise ratio the is good enough to measure low signal amplitude (15.7). Spontaneous firing events from CAD cells were successfully measured with VACNTs MEAs that were also found to be surprisingly robust toward the biological interactions. (paper)

  10. 3D-CAD Effects on Creative Design Performance of Different Spatial Abilities Students

    Science.gov (United States)

    Chang, Y.

    2014-01-01

    Students' creativity is an important focus globally and is interrelated with students' spatial abilities. Additionally, three-dimensional computer-assisted drawing (3D-CAD) overcomes barriers to spatial expression during the creative design process. Does 3D-CAD affect students' creative abilities? The purpose of this study was to explore the…

  11. Anthropometric parameters: weight height, body mass index and mammary volume in relationship with the mammographic pattern

    International Nuclear Information System (INIS)

    Perez-Candela, V.; Busto, C.; Avila, R.; Marrero, M. G.; Liminana, J. M.; Orengo, J. C.

    2001-01-01

    A prospective study to attempt to relate the anthropometric parameters of height, weight, body mass index as well as age with the mammographic patterns obtained for the patients and obtain an anthropometric profile was carried out. The study was performed in 1.000 women who underwent a mammography in cranial-caudal and medial lateral oblique projection of both breasts, independently of whether they were screened or diagnosed. Prior to the performance of the mammography, weight and height were obtained, and this was also performed by the same technicians, and the patient were asked their bra size to deduce breast volume. With the weight, the body mass index of Quetelet was calculated (weight [kg]/height''2 (ml). After reading the mammography, the patient was assigned to one of the four mammographic patterns considered in the BIRADS (Breast Imaging Reporting and Data System) established by the ACR (American College of Radiology): type I (fat). type II (disperse fibroglandular densities), type III (fibroglandular densities distributed heterogeneously), type 4 (dense). The results were introduced into a computer database and the SPSS 8.0 statistical program was applied, using the statistical model of multivariant logistic regression. In women under 40 years, with normal weight, the dense breast pattern accounted for 67.8% and as the body mass index (BMI) increased, this pattern decreased to 25.1%. The fat pattern is 20% and as the BMI increases, this increased to 80%. In 40-60 year old women with normal weight, the dense pattern accounts for 44% and decreases to 20.9% in the grades II, III and IV obese. The fat pattern is 11.1% and increases to 53.7% in the grade II, III and IV obese. In women over 60 with normal, the dense pattern accounts for 19.3% and and decreases to 13% in the grade III obese. The fat pattern is 5.3% and increases to 20.2% in the grade iii of obesity. As age increases, the probability of presenting a mammographic pattern with a fat image in the

  12. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    Science.gov (United States)

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (pChinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (pChinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  13. Improving performance of breast cancer risk prediction using a new CAD-based region segmentation scheme

    Science.gov (United States)

    Heidari, Morteza; Zargari Khuzani, Abolfazl; Danala, Gopichandh; Qiu, Yuchen; Zheng, Bin

    2018-02-01

    Objective of this study is to develop and test a new computer-aided detection (CAD) scheme with improved region of interest (ROI) segmentation combined with an image feature extraction framework to improve performance in predicting short-term breast cancer risk. A dataset involving 570 sets of "prior" negative mammography screening cases was retrospectively assembled. In the next sequential "current" screening, 285 cases were positive and 285 cases remained negative. A CAD scheme was applied to all 570 "prior" negative images to stratify cases into the high and low risk case group of having cancer detected in the "current" screening. First, a new ROI segmentation algorithm was used to automatically remove useless area of mammograms. Second, from the matched bilateral craniocaudal view images, a set of 43 image features related to frequency characteristics of ROIs were initially computed from the discrete cosine transform and spatial domain of the images. Third, a support vector machine model based machine learning classifier was used to optimally classify the selected optimal image features to build a CAD-based risk prediction model. The classifier was trained using a leave-one-case-out based cross-validation method. Applying this improved CAD scheme to the testing dataset, an area under ROC curve, AUC = 0.70+/-0.04, which was significantly higher than using the extracting features directly from the dataset without the improved ROI segmentation step (AUC = 0.63+/-0.04). This study demonstrated that the proposed approach could improve accuracy on predicting short-term breast cancer risk, which may play an important role in helping eventually establish an optimal personalized breast cancer paradigm.

  14. AutoCAD 2008 for dummies

    CERN Document Server

    Byrnes, David

    2007-01-01

    A gentle, humorous introduction to this fearsomely complex software that helps new users start creating 2D and 3D technical drawings right awayCovers the new features and enhancements in the latest AutoCAD version and provides coverage of AutoCAD LT, AutoCAD''s lower-cost siblingTopics covered include creating a basic layout, using AutoCAD DesignCenter, drawing and editing, working with dimensions, plotting, using blocks, adding text to drawings, and drawing on the InternetAutoCAD is the leading CAD software for architects, engineers, and draftspeople who need to create detailed 2D and 3D tech

  15. The VE/CAD synergism

    International Nuclear Information System (INIS)

    Sperling, R.B.

    1993-01-01

    Value Engineering (VE) and Computer-Aided Design (CAD) can be used synergistically to reduce costs and improve facilities designs. The cost and schedule impacts of implementing alternative design ideas developed by VE teams can be greatly reduced when the drawings have been produced with interactive CAD systems. To better understand the interrelationship between VE and CAD, the fundamentals of the VE process are explained; and example of a VE proposal is described and the way CAD drawings facilitated its implementation is illustrated

  16. The mammographic correlations of a new immunohistochemical classification of invasive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taneja, S. [Nottingham Breast Institute, City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom)], E-mail: sheeba_taneja@yahoo.co.uk; Evans, A.J. [Nottingham Breast Institute, City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Rakha, E.A.; Green, A.R. [Division of Pathology, School of Molecular Medical Sciences, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham (United Kingdom); Ball, G. [Nottingham Trent University, School of Biomedical and Natural Sciences, Nottingham (United Kingdom); Ellis, I.O. [Division of Pathology, School of Molecular Medical Sciences, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham (United Kingdom)

    2008-11-15

    Aim: Recent protein expression profiling of breast cancer has identified specific subtypes with clinical, biological, and therapeutic implications. The aim of this study was to identify the mammographic correlates of these novel molecular classes of invasive breast cancer. Materials and methods: The mammographic findings of 415 patients with operable breast cancer were correlated with the previously described protein expression classes identified by our group using immunohistochemical (IHC) assessment of a large series of breast cancer cases prepared as tissue microarrays (TMAs). Twenty-five proteins of known relevance in breast cancer were assessed, including hormone receptors, HER-2 status, basal and luminal markers, p53 expression, and E-cadherin. Results: The mammographic background pattern and proportion of lesions that were mammographically occult were similar in all groups. Groups characterized by luminal and hormone receptor positivity had significantly more spiculate lesions at mammography. Groups characterized by HER-2 overexpression, basal characteristics, and E-cadherin positivity had a significantly higher proportion of ill-defined masses. These findings were independent of histological grade. Conclusion: The mammographic features of breast cancer show significant correlation with molecular classes of invasive breast cancer identified by protein expression IHC analysis. The biological reasons for the findings and implications of these regarding imaging protocols require further study and may provide mechanisms for improvement of detection of these lesions.

  17. Evaluation of information-theoretic similarity measures for content-based retrieval and detection of masses in mammograms

    International Nuclear Information System (INIS)

    Tourassi, Georgia D.; Harrawood, Brian; Singh, Swatee; Lo, Joseph Y.; Floyd, Carey E.

    2007-01-01

    The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses

  18. Application of Auto CAD 2000

    International Nuclear Information System (INIS)

    Kim, Hyeong Jun

    1999-11-01

    This book deals with basic of AutoCAD, beginning AutoCAD 2000, using design center of AutoCAD 2000, adding drawing element with design center, drawing lines, using 2D edit command, making layer, hatching, dimensioning, entering letters on the floor plan, making 3D object, practice of 3D command, edition of 3D object, making solid, rendering object, and using internet in AutoCAD 2000. This book is introduction of AutoCAD 2000 for beginner.

  19. AutoCAD 2010 For Dummies

    CERN Document Server

    Byrnes, David

    2009-01-01

    AutoCAD is the hot computer-aided design software known for both its powerful tools and its complexity. AutoCAD 2010 for Dummies is the bestselling guide that walks you through this complicated program so you can build complex 3D technical drawings, edit like a pro, enter new dimensions, and plot with style. AutoCAD 2010 for Dummies helps you navigate the program, use the AutoCAD Design Center, create a basic layout and work with dimension, and put your drawings on the Internet. You'll soon be setting up the AutoCAD environment, using the AutoCAD Ribbon, creating annotation and dimension drawi

  20. Impact of contra-lateral breast reshaping on mammographic surveillance in women undergoing breast reconstruction following mastectomy for breast cancer.

    Science.gov (United States)

    Nava, Maurizio B; Rocco, Nicola; Catanuto, Giuseppe; Falco, Giuseppe; Capalbo, Emanuela; Marano, Luigi; Bordoni, Daniele; Spano, Andrea; Scaperrotta, Gianfranco

    2015-08-01

    The ultimate goal of breast reconstruction is to achieve symmetry with the contra-lateral breast. Contra-lateral procedures with wide parenchymal rearrangements are suspected to impair mammographic surveillance. This study aims to evaluate the impact on mammographic detection of mastopexies and breast reductions for contralateral adjustment in breast reconstruction. We retrospectively evaluated 105 women affected by uni-lateral breast cancer who underwent mastectomy and immediate two-stage reconstruction between 2002 and 2007. We considered three groups according to the contra-lateral reshaping technique: mastopexy or breast reduction with inferior dermoglandular flap (group 1); mastopexy or breast reduction without inferior dermoglandular flap (group 2); no contra-lateral reshaping (group 3). We assessed qualitative mammographic variations and breast density in the three groups. Statistically significant differences have been found when comparing reshaped groups with non reshaped groups regarding parenchymal distortions, skin thickening and stromal edema, but these differences did not affect cancer surveillance. The surveillance mammography diagnostic accuracy in contra-lateral cancer detection was not significantly different between the three groups (p = 0.56), such as the need for MRI for equivocal findings at mammographic contra-lateral breast (p = 0.77) and the need for core-biopsies to confirm mammographic suspect of contra-lateral breast cancer (p = 0.90). This study confirms previous reports regarding the safety of mastopexies and breast reductions when performed in the setting of contra-lateral breast reshaping after breast reconstruction. Mammographic accuracy, sensitivity and specificity are not affected by the glandular re-arrangement. These results provide a further validation of the safety of current reconstructive paradigms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Easy Auto CAD

    International Nuclear Information System (INIS)

    Lee, Hyeon Jun

    1996-02-01

    This book explains Auto CAD easily, which introduces improved function in Auto CAD R 13, such as direct import and export of 3 DS pile, revised render order structure, and explanations of assist, view Draw, construct and modify. Next it gives descriptions of Auto CAD conception, application and system. The last part deals with line, arc, circle, ellipse, erase, undo, redo, redraw, line type, multi line, limits, zoom, move, copy, rotate, array, mirror, grid, snap, units, offset and poly line.

  2. Absorbing CAD system geometries into GEANT

    International Nuclear Information System (INIS)

    Womersley, J.; Dragovitsch, P.; Youssef, S.

    1991-01-01

    The simulation community has for many years discussed the possibility of direct conversion of geometrical detector models from computer- aided design and engineering systems (CAD systems) to the simulation packages (which we shall assume means GEANT). This would allow fast and simultaneous optimization of the physics performance and structural integrity of detector designs. The benefit that this would offer is the avoidance of such problems as the late discovery of the rather thick cryostats in the D-Zero detector. Recent progress in the absorption of CAD geometries into GEANT models is reviewed, including descriptions of the additions to the I-DEAS solid modeller package developed for the EMPACT SSC proposal, the COGENT CAD-to-GEANT interpreter developed by Quantum Research Services, and the OCTAGON package for representing arbitrary shapes in GEANT. Likely future directions of development are described. 2 refs., 7 figs

  3. AutoCAD platform customization VBA

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Boost productivity and streamline your workflow with expert AutoCAD: VBA programming instruction AutoCAD Platform Customization: VBA is the definitive guide to personalizing AutoCAD and the various programs that run on the AutoCAD platform, including AutoCAD Architecture, Civil 3D, Plant 3D, and more. Written by an Autodesk insider with years of customization and programming experience, this book features detailed discussions backed by real-world examples and easy-to-follow tutorials that illustrate each step in the personalization process. Readers gain expert guidance toward managing layout

  4. The impact of mammographic screening on breast cancer mortality in Europe

    DEFF Research Database (Denmark)

    Moss, S M; Nyström, L; Jonsson, H.

    2012-01-01

    Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value.......Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value....

  5. Use of border information in the classification of mammographic masses

    International Nuclear Information System (INIS)

    Varela, C; Timp, S; Karssemeijer, N

    2006-01-01

    We are developing a new method to characterize the margin of a mammographic mass lesion to improve the classification of benign and malignant masses. Towards this goal, we designed features that measure the degree of sharpness and microlobulation of mass margins. We calculated these features in a border region of the mass defined as a thin band along the mass contour. The importance of these features in the classification of benign and malignant masses was studied in relation to existing features used for mammographic mass detection. Features were divided into three groups, each representing a different mass segment: the interior region of a mass, the border and the outer area. The interior and the outer area of a mass were characterized using contrast and spiculation measures. Classification was done in two steps. First, features representing each of the three mass segments were merged into a neural network classifier resulting in a single regional classification score for each segment. Secondly, a classifier combined the three single scores into a final output to discriminate between benign and malignant lesions. We compared the classification performance of each regional classifier and the combined classifier on a data set of 1076 biopsy proved masses (590 malignant and 486 benign) from 481 women included in the Digital Database for Screening Mammography. Receiver operating characteristic (ROC) analysis was used to evaluate the accuracy of the classifiers. The area under the ROC curve (A z ) was 0.69 for the interior mass segment, 0.76 for the border segment and 0.75 for the outer mass segment. The performance of the combined classifier was 0.81 for image-based and 0.83 for case-based evaluation. These results show that the combination of information from different mass segments is an effective approach for computer-aided characterization of mammographic masses. An advantage of this approach is that it allows the assessment of the contribution of regions rather

  6. AutoCAD workbook

    CERN Document Server

    Metherell, Phil

    1989-01-01

    AutoCAD Workbook helps new users learn the basics of AutoCad, providing guidance on most of the commonly used functions in which the program operates.This book discusses loading AutoCad and starting a drawing; drawing and erasing lines, circles, and arcs; and setting up the drawing environment. The topics on drawing and editing polylines; entering text and text styles; and layers, linetype, and color are also considered. This publication likewise covers creating and using blocks, hatching and extracting information, dimensioning drawings, 3D visualization, and plotting a drawing. Other

  7. Scattering influence in mammographic image

    International Nuclear Information System (INIS)

    Poletti, Martin Eduardo; Almeida, Adelaide de

    1996-01-01

    The quantification of mammographic images affected by scattered radiation is studied. The average glandular dose as a function of kVp and breast thickness for breast composition 50/50% is also evaluated. The results show that the contrast decreases with increasing of kVp and breast thickness, and the average glandular dose increase with increasing breast thickness and decreases with increasing kVp

  8. [The CAD-S, an instrument for the assessment of adaptation to divorce - separation].

    Science.gov (United States)

    Yárnoz Yaben, Sagrario; Comino González, Priscila

    2010-02-01

    The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.

  9. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  10. Bilateral breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Oh, Ki Keun; Jun, Hwang Yoon; Lee, Byung Chan; Lee, Kyong Sik; Lee, Yong Hee

    1997-01-01

    To evaluate the mammographic and clinical features of bilateral breast cancer. We retrospectively reviewed clinical records(n=23) and mammograms (n=15) of 23 patients with bilateral breast cancer. Patients' age, location of the tumor and pathologic staging were determined from clinical records. Mammographic features were classified as spiculated mass, nonspiculated mass, mass with microcalcification, microcalcification only, asymmetric density, and normal. Of the 23 cases of bilateral breast cancer, 8(34.8%) were synchronous and 15(65.2%) were metachronous. Age at diagnosis of cancer in the first breast was between 27 and 59(mean 43) years ; there was no statistically significant difference in mean age between patients with synchronous and metachronous cancer. The mean interval between the diagnosis of each lesion of the metachronous pairs was 9.1 years. In 11 of 23 cases(48%), tumors were locaated in the same quadrant, and in the other 12 cases(52%), they were in different quadrant. At mammography, five of 15 metachronous cancers(33%) were similar in appearance and 10 pairs(67%) were different. In 4 of 23 cases(17%), cancer in the first breast was at stage 0 and stage 1, and in 13 of 23(57%), cancer in the second breast was at this same stage. In bilateral breast cancer, the two breasts frequently show different mammographic features. Cancer of the second breast was at an early stage; this suggest that regular examination and mammography are important and can allow early detection of contralateral breast cancer

  11. CAD on personal computers

    International Nuclear Information System (INIS)

    Lee, Seong U; Cho, Cheol Ho; Ko, Il Du

    1990-02-01

    This book contains four studies of CAD on personal computers. The first thing is computer graphics in computer-aided design by Seong U Lee. The second thing is graphics primer and programming with Fortran by Seong U Lee. The third thing is application of Auto cad by Il Do Ko. The last thing is application of CAD in building construction design by Cheol Ho Cho.

  12. The clinical and mammographic features of plasma cell mastitis

    International Nuclear Information System (INIS)

    Wu Xiurong; Luo Xiaohua; Yu Xuming; Zhong Shan; Huang Yufan; Wu Xinyi; Lin Yubin

    2007-01-01

    Objective: To investigate the clinical and mammographic features of plasma cell mastitis. Methods: Twenty-five patients (28 lesions) with histologically confirmed plasma cell mastitis, aged from 26 to 70 years (mean age 41 years), were examined with X-ray mammography. The clinical manifestations and imaging features were retrospectively reviewed. Results: No case was in lactation. The painful irregular masses, ranged from 1.3 to 8cm in size, were found in 22 patients, while 3 patients with acute episode. Recurrent episodes of breast masses were noted in 4 patients. Based on the mammographic appearances, the plasma cell mastitis were classified as the following four types: inflammation-like type (2/28), ductal ectasia type (3/28), focal infiltration type (10/28) and nodular type (13/28). The valuable radiographic signs: (1) An asymmetrically increased density along the lactiferous duct with a flame-like appearance, inhomogeneous low density tubular structures and scattered stick-shape calcifications. (2) Architectural distortion and oil cysts formation in adjacent area, (3) Subareolar ductal ectasia. Conclusions: The clinical and mammographic characteristics of plasma cell mastitis are critical to avoiding unnecessary surgery. Histopathological result is needed for the diagnosis in patients highly suspected of malignancy. (authors)

  13. Breast Tissue Composition and Immunophenotype and Its Relationship with Mammographic Density in Women at High Risk of Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Jia-Min B Pang

    Full Text Available To investigate the cellular and immunophenotypic basis of mammographic density in women at high risk of breast cancer.Mammograms and targeted breast biopsies were accrued from 24 women at high risk of breast cancer. Mammographic density was classified into Wolfe categories and ranked by increasing density. The histological composition and immunophenotypic profile were quantified from digitized haematoxylin and eosin-stained and immunohistochemically-stained (ERα, ERβ, PgR, HER2, Ki-67, and CD31 slides and correlated to mammographic density.Increasing mammographic density was significantly correlated with increased fibrous stroma proportion (rs (22 = 0.5226, p = 0.0088 and significantly inversely associated with adipose tissue proportion (rs (22 = -0.5409, p = 0.0064. Contrary to previous reports, stromal expression of ERα was common (19/20 cases, 95%. There was significantly higher stromal PgR expression in mammographically-dense breasts (p=0.026.The proportion of stroma and fat underlies mammographic density in women at high risk of breast cancer. Increased expression of PgR in the stroma of mammographically dense breasts and frequent and unexpected presence of stromal ERα expression raises the possibility that hormone receptor expression in breast stroma may have a role in mediating the effects of exogenous hormonal therapy on mammographic density.

  14. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    Science.gov (United States)

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p CAD (p = 0.0115), and Lava Ultimate (p CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the

  15. AutoCAD 2012 and AutoCAD LT 2012 No Experience Required

    CERN Document Server

    Gladfelter, Donnie

    2011-01-01

    The perfect step-by-step introduction to Autodesk's powerful architectural design software With this essential guide, you'll learn how to plan, develop, document, and present a complete AutoCAD project by building a summer cabin from start to finish. You can follow each step sequentially or jump in at any point by downloading the drawing files from the book's companion web site. You'll also master all essential AutoCAD features, get a thorough grounding in the basics, learn the very latest industry standards and techniques, and quickly become productive with AutoCAD 2012.Features concise expla

  16. Vragenlijst ter beoordeling van beeldschermtekenfuncties (CAD)

    NARCIS (Netherlands)

    Berndsen, M.B.; Vaas, F.

    1990-01-01

    Deze vragenlijst is een hulpmiddel om beeldscherm-tekenfuncties (CAD) waarbij gebruik wordt gemaakt van CAD-apparatuur, te beoordelen. Het gaat hierbij om functies waarin bij de hoofdtaken intensief met een beeldscherm wordt gewerkt, zoals het geval is bij de CAD-tekenaar, de CAD-instructeur en de

  17. Evaluation of Five Microcomputer CAD Packages.

    Science.gov (United States)

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…

  18. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  19. Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

    Energy Technology Data Exchange (ETDEWEB)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Giger, Maryellen L.; Li, Hui [Department of Radiology, University of Chicago, Chicago, Illinois 60637 (United States); Duewer, Fred; Malkov, Serghei; Joe, Bonnie; Kerlikowske, Karla; Shepherd, John A. [Radiology Department, University of California, San Francisco, California 94143 (United States); Flowers, Chris I. [Department of Radiology, University of South Florida, Tampa, Florida 33612 (United States); Drukteinis, Jennifer S. [Department of Radiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida 33612 (United States)

    2014-03-15

    Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

  20. Mammographic varicosities indicative of a superior mediastinal ...

    African Journals Online (AJOL)

    In addition, an abnormal calibre of the superficial veins can reflect not only underrying breast pathology, but a collateral venous return resulting from an upper mediastinal obstruction. A case mammographically demonstrating mammary varicosities resulting from a superior mediastinal syndrome is described. S. Afr. Med.

  1. Easy Korean Auto CAD 14

    International Nuclear Information System (INIS)

    Lee, Jae Cheol

    1997-10-01

    This book introduces Auto CAD 14, which includes summary of basic things of Auto CAD 14, user interface for Auto CAD, basic drawing and advice, layer and set-up drawing, drawing with Auto CAD tools exactly, basic drawing of every thing, edit command, control of display, modeling and view ports of drawing space, various things drawing, writing letters, modification of floor plan, and check, block, X ref, lines and hatch, writing measurement, floor plan and OLE exchange of data, 3D floor plan, and rendering and presentation.

  2. The significance of circumscribed malignant mammographic masses in the surveillance of BRCA 1/2 gene mutation carriers

    International Nuclear Information System (INIS)

    Kaas, R.; Kroger, R.; Besnard, A.P.E.; Koops, W.; Pameijer, F.A.; Prevoo, W.; Loo, C.E.; Muller, S.H.; Hendriks, J.H.C.L.

    2004-01-01

    Breast cancers in gene mutation carriers may escape mammographic detection because of rapid growth and tumor expansion. Therefore, they may mimic benign lesions on the mammogram. Twenty-nine BRCA 1/2 mutation carriers under surveillance developed 31 breast cancers between 1994 and 2001 at a mean age of 44.2 years. Controls were 63 women with 67 breast cancers in the same period at a mean age of 53.8 years, also under surveillance because of a life time risk of at least 15%. In 26% of the carriers vs. 48% of the controls, mammography was the method that first suspected a malignancy. Seven radiologists performed a retrospective review of the original mammograms to establish technical assessment, with special attention for circumscribed lesions and estimated probability of malignancy. In the mutation carriers seven (23%) circumscribed non-calcified mammographic masses were found and three in the controls (4.5%) P=0.01. These masses were proven to be malignant. In both groups around 70% of these fast-growing circumscribed lesions were detected by the patients. The masses were situated in breasts with a good interpretable breast pattern. BRCA 1/2 mutation carriers had a significantly higher percentage of circumscribed non-calcified mammographic masses that proved to be malignant. These mammographic lesions in women at high risk should be described as at least Birads 0 and worked-up with ultrasound and needle biopsy. (orig.)

  3. Towards an automatic tool for resolution evaluation of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    De Oliveira, J. E. E. [FUMEC, Av. Alfonso Pena 3880, CEP 30130-009 Belo Horizonte - MG (Brazil); Nogueira, M. S., E-mail: juliae@fumec.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, 31270-901, Belo Horizonte - MG (Brazil)

    2014-08-15

    Medical images are important for diagnosis purposes as they are related to patients medical history and pathology. Breast cancer represents a leading cause of death among women worldwide, and its early detection is the most effective method of reducing mortality. In a way to identify small structures with low density differences, a high image quality is required with the use of low doses of radiation. The analysis of the quality of the obtained image from a mammogram is performed from an image of a simulated breast and this is a fundamental key point for a program of quality control of mammography equipment s. In a control program of mammographic equipment s, besides the analysis of the quality of mammographic images, each element of the chain which composes the formation of the image is also analyzed: X-rays equipment s, radiographic films, and operating conditions. This control allows that an effective and efficient exam can be provided to the population and is within the standards of quality required for the early detection of breast cancer. However, according to the State Program of Quality Control in Mammography of Minas Gerais, Brazil, only 40% of the mammographies have provided a simulated image with a minimum level of quality, thus reinforcing the need for monitoring the images. The reduction of the morbidity and mortality indexes, with optimization and assurance of access to diagnosis and breast cancer treatment in the state of Minas Gerais, Brazil, may be the result of a mammographic exam which has a final image with good quality and which automatic evaluation is not subjective. The reason is that one has to consider the hypothesis that humans are subjective when performing the image analysis and that the evaluation of the image can be executed by a computer with objectivity. In 2007, in order to maintain the standard quality needed to mammography, the State Health Secretariat of Minas Gerais, Brazil, established a Program of Monthly Monitoring the

  4. Towards an automatic tool for resolution evaluation of mammographic images

    International Nuclear Information System (INIS)

    De Oliveira, J. E. E.; Nogueira, M. S.

    2014-08-01

    Medical images are important for diagnosis purposes as they are related to patients medical history and pathology. Breast cancer represents a leading cause of death among women worldwide, and its early detection is the most effective method of reducing mortality. In a way to identify small structures with low density differences, a high image quality is required with the use of low doses of radiation. The analysis of the quality of the obtained image from a mammogram is performed from an image of a simulated breast and this is a fundamental key point for a program of quality control of mammography equipment s. In a control program of mammographic equipment s, besides the analysis of the quality of mammographic images, each element of the chain which composes the formation of the image is also analyzed: X-rays equipment s, radiographic films, and operating conditions. This control allows that an effective and efficient exam can be provided to the population and is within the standards of quality required for the early detection of breast cancer. However, according to the State Program of Quality Control in Mammography of Minas Gerais, Brazil, only 40% of the mammographies have provided a simulated image with a minimum level of quality, thus reinforcing the need for monitoring the images. The reduction of the morbidity and mortality indexes, with optimization and assurance of access to diagnosis and breast cancer treatment in the state of Minas Gerais, Brazil, may be the result of a mammographic exam which has a final image with good quality and which automatic evaluation is not subjective. The reason is that one has to consider the hypothesis that humans are subjective when performing the image analysis and that the evaluation of the image can be executed by a computer with objectivity. In 2007, in order to maintain the standard quality needed to mammography, the State Health Secretariat of Minas Gerais, Brazil, established a Program of Monthly Monitoring the

  5. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    International Nuclear Information System (INIS)

    MORRIS, J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-01-01

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods

  6. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    MORRIS,J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-10-15

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods.

  7. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  8. Multifunctional facades - design optimisation with CAD; Multifunktionale Fassaden - Effektive Auslegung durch CAD-Einsatz

    Energy Technology Data Exchange (ETDEWEB)

    Viotto, M. [Institut fuer Solare Energieversorgungstechnik (ISET), Kassel (Germany). Abt. fuer Anlagen- und Messtechnik

    1998-02-01

    The energetically optimal design of PV facades requires the consideration of many technical conditions (different elevations/orientations of modules; shading possibility; high and different module temperatures). It also requires the interface with architecture, civil and electrical engineering. To support this planning process, the software program PV-CAD was developed which rapidly calculates energy yield under conditions of inhomogeneous irradiance, shading, thermal behaviour of modules and electrical layout. PV-CAD is compatible with other civil and electrical engineering CAD programs and incorporates extensive databases (weather data; modules and inverter types). (orig.) [Deutsch] Fuer optimalen Energieertrag sind zahlreiche technische Randbedingungen bei der Auslegung einer Photovoltaik (PV)-Fassade zu beruecksichtigen (unterschiedliche Ausrichtungen/Neigungen der Module; moegliche Teilabschattung; hoehere und unterschiedliche Betriebstemperaturen). Installation und Betrieb einer PV-Fassade erfordern die Abstimmung zwischen Architektur, Bauwesen und Elektrotechnik. Zur Unterstuetzung der Planer wurde das Programm PV-CAD entwickelt, das den Energieertrag unter Beruecksichtigung von inhomogener Einstrahlung und Abschattung, Temperaturverhalten der Fassadenmodule sowie unterschiedlichen elektrischen Anlagenkonzepten schnell ermittelt; es fuegt sich nahtlos in CAD-Arbeitsumgebungen ein. (orig.)

  9. Particle tracking in sophisticated CAD models for simulation purposes

    International Nuclear Information System (INIS)

    Sulkimo, J.; Vuoskoski, J.

    1995-01-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT. (orig.)

  10. Particle tracking in sophisticated CAD models for simulation purposes

    Science.gov (United States)

    Sulkimo, J.; Vuoskoski, J.

    1996-02-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT.

  11. Mammographic findings predicting an extensive intraductal component in early stage invasive breast cancer : analysis on microcalcification

    International Nuclear Information System (INIS)

    Kim, Jeong Ah; Kim, Mi Hye; Lee, Mi Kyung; Oh, Ki Keun; Kim, Eun Kyung

    2000-01-01

    To analyze the mammographic findings of extensive intraductal component (EIC)-positive early invasive breast carcinoma and to determine the mammographic features which predict an EIC positivity in an invasive carcinoma. The mammographic and pathologic findings in 71 patients aged 34-79 (mean 50) years in whom stage I or II invasive breast carcinoma had been diagnosed were retrospectively analysed. The mammographic findings were assigned to one of three groups: mass, mass with microcalcification, or microcalcification only. The shape and distribution of a calcification were classified according to the BI-RADS lexicon, and its extent was classified as either more or less than 3 cm. To detect the presence or absence of EIC and the type of ductal carcinoma in situ (DCIS), the findings were re-examined by means of slide mappings. Twenty-eight of 71 patients (39%) showed ECI positivity. The mammographic findings of EIC-positive invasive cancer (n=3D28) were mass with microcalcification (n=3D14), microcalcification only (n=3D7) and mass only (n=3D7). The mammographic finding which predicted EIC positivity was mass with microcalcification (PPV:0.67, NPV:0.33, p=3D0.02). A mammographic of mass only (n=3D39) showed a significantly high negative predictive value for EIC positivity. (PPV 0.18, NPV 0.82, P less than 0.01). A comparison of cases with or without calcification showed that those with microcalcifications (n=3D32) showed a significantly high PPV of 0.66 (NPV:0.34, p less than 0.01) while those without calcification (n=3D39) showed a significantly high NPV of 0.82 (PPV:0.18, p less than 0.01). There were no significant differences in positive predictive values for EIC between the shape, distribution and extent of calcifications. Whenever microcalcification with or without mass is seen on mammographs obtained during early breast cancer, we can predict EIC-positivity, regardless of shape or distribution according to the BI-RADS lexicon. (author)

  12. Multiscale wavelet representations for mammographic feature analysis

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu

    1992-12-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet coefficients, enhanced by linear, exponential and constant weight functions localized in scale space. By improving the visualization of breast pathology we can improve the changes of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  13. Cool-and Unusual-CAD Applications

    Science.gov (United States)

    Calhoun, Ken

    2004-01-01

    This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)

  14. AutoCAD 2015 and AutoCAD LT 2015

    CERN Document Server

    Gladfelter, Donnie

    2014-01-01

    Learn AutoCAD by example with this tutorial-based guide from Autodesk Official Press Whether you are just starting out or an experienced user wanting to brush up on your skills, this Autodesk Official Press book provides you with concise explanations, focused examples, and step-by-step instructions through a hands-on tutorial project that runs throughout the book. As you progress through the project, the book introduces you to the Microsoft Windows-based AutoCAD interface and then guides you through basic commands and creating drawings. A downloadable file is available from the website so that

  15. Comparative analysis among X-ray mammographic findings, nuclear and histologic grading, and TNM staging of breast carcinoma

    International Nuclear Information System (INIS)

    Park, Jin Sook; Sung, Ki Joon; Cho, Mee Yon; Hong, In Soo; Kim, Myung Soon; Oh, Ki Keun

    1996-01-01

    The purpose of this study was to evaluate the prognosis of breast carcinoma by comparison with X-ray mammographic findings, nuclear and histologic grade, and TNM staging. We retrospectively reviewed 114 cases (113 patients) of breast carcinoma, analysing X-ray mammographic findings of all cases with regard to mass, calcification, and spiculation. In 80 cases of scirrhous invasive ductal breast carcinoma. Black's nuclear and Bloom-Richardson's histologic grade were also evaluated. Mammographic findings and nuclear and histologic grade were compared with TNM staging which might suggest the prognosis of breast carcinoma. X-ray mammographic findings (mass, calcification and spiculation) did not significantly correlate with T staging, but the clinical staging of the spiculation was advanced. These X-ray findings did not significantly correlate with the nuclear grading and the histologic grading. Nuclear grade did not correlate with T and M staging, but correlated significantly with N staging and clinical stage(p < 0.05). Histologic grade did not significantly correlate with TNM staging. The clinical staging of spiculation was advanced and nuclear grade correlated significantly with N stage and clinical staging. X-ray mammographic findings did not directly correlate with nuclear and histologic grading, but combined studies of the evaluation of mammographic findings and nuclear and histologic grade were useful for prognosing breast carcinoma

  16. AutoCAD 2014 essentials

    CERN Document Server

    Onstott, Scott

    2013-01-01

    Learn crucial AutoCAD tools and techniques with this Autodesk Official Press Book Quickly become productive using AutoCAD 2014 and AutoCAD LT 2014 with this full color Autodesk Official Press guide. This unique learning resource features concise, straightforward explanations and real-world, hands-on exercises and tutorials. Following a quick discussion of concepts and goals, each chapter moves on to an approachable hands-on exercise designed to reinforce real-world tactics and techniques. Compelling, full-color screenshots illustrate tutorial steps, and chapters conclude with relat

  17. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    Science.gov (United States)

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Po-Hao, E-mail: howard_chen@post.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Department of Radiology, Hospital of University of Pennsylvania, 3400 Spruce Street, Philadlephia, PA 19104 (United States); Slanetz, Priscilla J., E-mail: pslanetz@bidmc.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Beth Israel Deaconess Medical Center, Department of Radiology, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2014-01-15

    Purpose: To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Materials and Methods: Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. Results: A total of 353 mammograms were obtained from 327 unique patients (ages 18–95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Conclusion: Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management.

  19. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    International Nuclear Information System (INIS)

    Weinhorst, Bastian; Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng; Wilson, Paul

    2015-01-01

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  20. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Wilson, Paul [University of Wisconsin-Madison, Computational Nuclear Engineering Research Group, Madison, WI (United States)

    2015-10-15

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  1. Agreement of mammographic measures of volumetric breast density to MRI.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population.Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume.Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2 values ranging from 0.40 (log fibroglandular volume to 0.91 (total breast volume. Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63, but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume.Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  2. Agreement of mammographic measures of volumetric breast density to MRI.

    Science.gov (United States)

    Wang, Jeff; Azziz, Ania; Fan, Bo; Malkov, Serghei; Klifa, Catherine; Newitt, David; Yitta, Silaja; Hylton, Nola; Kerlikowske, Karla; Shepherd, John A

    2013-01-01

    Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  3. Ethnic Differences in Mammographic Densities: An Asian Cross-Sectional Study

    Science.gov (United States)

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Background Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. Methods A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Results Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (p<0.001), after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (p<0.001), but dense area did not differ across the three ethnic groups. Conclusions Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort. PMID:25659139

  4. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Shivaani Mariapun

    Full Text Available BACKGROUND: Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. METHODS: A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. RESULTS: Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0% compared to Malay (24.2%; 95% CI 22.5%, 26.0% and Indian (24.3%; 95% CI 22.8%, 25.7% women (p<0.001, after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2 women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2 and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2 women (p<0.001, but dense area did not differ across the three ethnic groups. CONCLUSIONS: Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  5. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  6. CAD: Designs on Business.

    Science.gov (United States)

    Milburn, Ken

    1988-01-01

    Provides a general review of the field of Computer-Aided Design Software including specific reviews of "Autosketch,""Generic CADD,""Drafix 1 Plus,""FastCAD," and "Autocad Release 9." Brief articles include "Blueprint for Generation,""CAD for Every Department,""Ideas…

  7. Sclerosing adenosis: mammographic and ultrasonographic findings with clinical and histopathological correlation

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Memis, Aysenur; Uestuen, Esin Emin; Oezdemir, Necmettin; Erhan, Yildiz

    2002-01-01

    Objective: To evaluate the mammographic and ultrasonographic findings of sclerosing adenosis, a relatively uncommon entity which may sometimes mimic carcinoma. Materials and methods: A retrospective review of the records of 33700 women, who have undergone mammographic examination at our institution between January 1985 and July 2001 revealed 43 histopathologically proven sclerosing adenosis. The history, physical examination, mammographic and ultrasonographic findings were analyzed in all patients. In 30 patients, the nonpalpable lesions were preoperatively localized by the needle-hookwire system under the guidance of mammography (n=22) or ultrasonography (US) (n=8). Radiological features were correlated with histopathological findings. Results: The age of the patients varied between 32 and 55 years (mean, 43.7 years). Only two patients had a family history of breast cancer. In six patients, the presenting complaint was mastalgia. A palpable mass was present in 13 cases. The mammographic findings were; microcalcifications in 24 (55.8%) (clustered in 22, diffuse in two), mass in five (11.6%), asymmetric focal density in three (6.9%), and focal architectural distortion in three (6.9%) patients. Four of the masses were irregularly contoured, while one was well-circumscribed. On US, focal acoustic shadowing without a mass configuration was noted in the three patients who showed asymmetrical focal density on mammography. In eight patients, who showed normal mammograms, a solid mass was detected on US. Two masses had discrete well-circumscribed oval or lobulated contours, while six showed microlobulation and irregularity. In one case, the irregularly contoured mass had marked posterior acoustic shadowing. Two of the three patients, who had focal architectural distortion on mammograms, had an irregularly contoured solid mass, while the third presented as focal acoustic shadowing without a mass configuration. Conclusion: Sclerosing adenosis mostly presents as a nonpalpable

  8. Mammographer personality traits – elements of the optimal ...

    African Journals Online (AJOL)

    2014-11-07

    Nov 7, 2014 ... competency, good communication skills and the ability to limit patient anxiety and ... personality traits in mammographers in order of importance .... 1 (trust) is high, with a Cronbach's alpha of 0.911 and inter- item reliability ...

  9. Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Samei, Ehsan; Saunders, Robert; Abbey, Craig; Delong, David

    2007-01-01

    The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures

  10. A tool to convert CAD models for importation into Geant4

    Science.gov (United States)

    Vuosalo, C.; Carlsmith, D.; Dasu, S.; Palladino, K.; LUX-ZEPLIN Collaboration

    2017-10-01

    The engineering design of a particle detector is usually performed in a Computer Aided Design (CAD) program, and simulation of the detector’s performance can be done with a Geant4-based program. However, transferring the detector design from the CAD program to Geant4 can be laborious and error-prone. SW2GDML is a tool that reads a design in the popular SOLIDWORKS CAD program and outputs Geometry Description Markup Language (GDML), used by Geant4 for importing and exporting detector geometries. Other methods for outputting CAD designs are available, such as the STEP format, and tools exist to convert these formats into GDML. However, these conversion methods produce very large and unwieldy designs composed of tessellated solids that can reduce Geant4 performance. In contrast, SW2GDML produces compact, human-readable GDML that employs standard geometric shapes rather than tessellated solids. This paper will describe the development and current capabilities of SW2GDML and plans for its enhancement. The aim of this tool is to automate importation of detector engineering models into Geant4-based simulation programs to support rapid, iterative cycles of detector design, simulation, and optimization.

  11. Invasive ductal carcinoma vs. invasive lobular carcinoma; mammographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chun; Do, Young Soo; Oh, Hoon Il; Han, Yoon Hee; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1996-01-01

    The purpose of this study is to evaluate mammographic findings of invasive ductal carcinoma (IDC) and invasive lobular carcinoma(ILC) and to find differential points between the two. 239 patients, who underwent mammography prior to surgery and were proved to have IDC(patients) or ILC(15 patients) pathologically, were analized retrospectively. On mammogram, presence of mass and microcalcification were analized. When there was a mass on mammogram, lesion opacity was classified into high, equal, or low opacity and border of the mass was classified into spiculated, poorly marginated, and well-marginated. When there was no definite mass, mammographic findings were classifie into asymmetric opacity and no mass. Masses were observed in 168 patients(75%) of IDC and 12 patients(80%) of ILC. Border of the masses were spiculated(n=50, 22.3%), poorly marginated(n=112, 50%), or well-marginated(n=6, 2.7%) in patients with IDC. Spiculated and poorly marginated borders were observed in 8 patients(53.3%) and 4 patients(26.7%) respectively, in patients with ILC. Microcalcifications were seen in 88 patients(17.3%) of IDC and patients(33.3%) of ILC. Although equal or low opacities were observed more frequently in ILC and microcalcifications were noted more frequently in IDC, it was difficult to differentiate the two diseases based on mammographic findings.

  12. Invasive ductal carcinoma vs. invasive lobular carcinoma; mammographic findings

    International Nuclear Information System (INIS)

    Lee, Eun Chun; Do, Young Soo; Oh, Hoon Il; Han, Yoon Hee; Kim, Ki Soo; Chin, Soo Yil

    1996-01-01

    The purpose of this study is to evaluate mammographic findings of invasive ductal carcinoma (IDC) and invasive lobular carcinoma(ILC) and to find differential points between the two. 239 patients, who underwent mammography prior to surgery and were proved to have IDC(patients) or ILC(15 patients) pathologically, were analized retrospectively. On mammogram, presence of mass and microcalcification were analized. When there was a mass on mammogram, lesion opacity was classified into high, equal, or low opacity and border of the mass was classified into spiculated, poorly marginated, and well-marginated. When there was no definite mass, mammographic findings were classifie into asymmetric opacity and no mass. Masses were observed in 168 patients(75%) of IDC and 12 patients(80%) of ILC. Border of the masses were spiculated(n=50, 22.3%), poorly marginated(n=112, 50%), or well-marginated(n=6, 2.7%) in patients with IDC. Spiculated and poorly marginated borders were observed in 8 patients(53.3%) and 4 patients(26.7%) respectively, in patients with ILC. Microcalcifications were seen in 88 patients(17.3%) of IDC and patients(33.3%) of ILC. Although equal or low opacities were observed more frequently in ILC and microcalcifications were noted more frequently in IDC, it was difficult to differentiate the two diseases based on mammographic findings

  13. Size, node status and grade of breast tumours: association with mammographic parenchymal patterns

    Energy Technology Data Exchange (ETDEWEB)

    Sala, E.; Solomon, L.; McCann, J. [Department of Community Medicine, Strangeways Research Laboratory, Worts Causeway, Cambridge (United Kingdom); Warren, R. [Cambridge and Huntingdon Breast Screening Service, Rosie Maternity Hospital, Robinson Way, Cambridge (United Kingdom); Duffy, S. [MRC-Biostatistics Unit, Institute of Public Health, Cambridge (United Kingdom); Luben, R. [Department of Clinical Gerontology, Strangeways Research Laboratory, Cambridge (United Kingdom); Day, N. [Department of Community Medicine, Institute of Public Health, Robinson Way, Cambridge, CB2 2SR (United Kingdom)

    2000-01-01

    A case-control study was designed to assess the association of mammographic parenchymal patterns with the risk of in-situ and invasive breast cancer. In addition, the relationship between tumour characteristics and mammographic patterns were also investigated. A total of 875 patients with breast cancer were selected and matched with 2601 controls. Mammographic parenchymal patterns of breast tissue were assessed according to Wolfe's classification, and statistical analysis was by conditional logistic regression. Relative to the N1 pattern, the odds ratios of having an invasive breast cancer associated with the P2 and DY patterns were 1.8 and 1.4, respectively. In addition, the odd ratios of having an invasive grade 3 breast cancer associated with the P2 and DY patterns were 2.8 and 3.9, respectively. Relative to the combined N1/P1 pattern, the odd ratios of having a breast cancer smaller than 14 mm, 15-29 mm, or larger than 30 mm associated with the combined high-risk P2/DY pattern (P2 + DY) were 1.2, 1.6, and 2.0, respectively. Finally, women with the P2/DY pattern were twice as likely to have a breast cancer which had already spread to the axillary nodes, compared to women with women with the N1/P1 pattern (odds ratios of 2.1 and 1.4, respectively). Our results confirm previous findings suggesting that mammographic parenchymal patterns may serve as indicators of risk for breast cancer. Our results also suggest that mammographic parenchymal patterns are associated with the stage at which breast cancer is detected. (orig.)

  14. Size, node status and grade of breast tumours: association with mammographic parenchymal patterns

    International Nuclear Information System (INIS)

    Sala, E.; Solomon, L.; McCann, J.; Warren, R.; Duffy, S.; Luben, R.; Day, N.

    2000-01-01

    A case-control study was designed to assess the association of mammographic parenchymal patterns with the risk of in-situ and invasive breast cancer. In addition, the relationship between tumour characteristics and mammographic patterns were also investigated. A total of 875 patients with breast cancer were selected and matched with 2601 controls. Mammographic parenchymal patterns of breast tissue were assessed according to Wolfe's classification, and statistical analysis was by conditional logistic regression. Relative to the N1 pattern, the odds ratios of having an invasive breast cancer associated with the P2 and DY patterns were 1.8 and 1.4, respectively. In addition, the odd ratios of having an invasive grade 3 breast cancer associated with the P2 and DY patterns were 2.8 and 3.9, respectively. Relative to the combined N1/P1 pattern, the odd ratios of having a breast cancer smaller than 14 mm, 15-29 mm, or larger than 30 mm associated with the combined high-risk P2/DY pattern (P2 + DY) were 1.2, 1.6, and 2.0, respectively. Finally, women with the P2/DY pattern were twice as likely to have a breast cancer which had already spread to the axillary nodes, compared to women with women with the N1/P1 pattern (odds ratios of 2.1 and 1.4, respectively). Our results confirm previous findings suggesting that mammographic parenchymal patterns may serve as indicators of risk for breast cancer. Our results also suggest that mammographic parenchymal patterns are associated with the stage at which breast cancer is detected. (orig.)

  15. When and why might a Computer Aided Detection (CAD) system interfere with visual search? An eye-tracking study

    Science.gov (United States)

    Drew, Trafton; Cunningham, Corbin; Wolfe, Jeremy

    2012-01-01

    Rational and Objectives Computer Aided Detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. Methods 47 naïve observers in two studies were asked to search for a target, embedded in 1/f2.4 noise while we monitored their eye-movements. For some observers, a CAD system marked 75% of targets and 10% of distractors while other observers completed the study without CAD. In Experiment 1, the CAD system’s primary function was to tell observers where the target might be. In Experiment 2, CAD provided information about target identity. Results In Experiment 1, there was a significant enhancement of observer sensitivity in the presence of CAD (t(22)=4.74, pCAD system were missed more frequently than equivalent targets in No CAD blocks of the experiment (t(22)=7.02, pCAD, but also no significant cost on sensitivity to unmarked targets (t(22)=0.6, p=n.s.). Finally, in both experiments, CAD produced reliable changes in eye-movements: CAD observers examined a lower total percentage of the search area than the No CAD observers (Ex 1: t(48)=3.05, pCAD signals do not combine with observers’ unaided performance in a straight-forward manner. CAD can engender a sense of certainty that can lead to incomplete search and elevated chances of missing unmarked stimuli. PMID:22958720

  16. Mammographic changes in postmenopausal women : comparative effects between continuous combined hormone and single estrogen replacement therapy

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Sug; Choi, Jong Tae; Jung, Kyoon Soon; Jung, Seung Hye [Jeil Women' s Hospital, Seoul (Korea, Republic of)

    1997-06-01

    As the use of hormone replacement therapy for the menopausal women increases, some caution is advised, since there is an increased risk of breast cancer. Accordingly, the importance of regular mammography has been addressed. This cross-setional study analyzed the effects of different hormone therapies on mammographic density. Sixty-seven postemenopausal women who had completed one year of hormone therapy and had undergone follow-up mammography, were divided into two groups : Group I : continuous conjugated equine estrogen, 0.625mg, plus continuous medroxyprogesterone acetate, 2.5mg (n=48), Group II : continuous conjugated equine estrogen 0.625mg (n=19). The mammograms were read by two radiologists. With regard to the radiologists involved, interobserver reliabillity (kappa) was 0.70 and intraobserver reliability (kappa) was 0.51 and 0.67. Before hormone therapy, factors related to decreased mammographic density were age and number of full term pregnancies (p<0.05). After one year of hormone therapy, body fat showed a significant increase (p<0.05), but in spite of this, increased mammographic density induced by hormone therapy remained significantly high (p<0.05). Compared with Group II, Group I showed a significant increase in mammographic density (p<0.05). In Group I, mammographic density increased from P2 to DY pattern in two cases, but there was no such change in Group II. The increase of mammographic density seen in Group II was much more significant statistically than that seen in Group I. The mammograms of women who have undergone continuous combined hormone therapy should therefore be interpreted very cautiously.

  17. Mammographic changes in postmenopausal women : comparative effects between continuous combined hormone and single estrogen replacement therapy

    International Nuclear Information System (INIS)

    Oh, Sug; Choi, Jong Tae; Jung, Kyoon Soon; Jung, Seung Hye

    1997-01-01

    As the use of hormone replacement therapy for the menopausal women increases, some caution is advised, since there is an increased risk of breast cancer. Accordingly, the importance of regular mammography has been addressed. This cross-setional study analyzed the effects of different hormone therapies on mammographic density. Sixty-seven postemenopausal women who had completed one year of hormone therapy and had undergone follow-up mammography, were divided into two groups : Group I : continuous conjugated equine estrogen, 0.625mg, plus continuous medroxyprogesterone acetate, 2.5mg (n=48), Group II : continuous conjugated equine estrogen 0.625mg (n=19). The mammograms were read by two radiologists. With regard to the radiologists involved, interobserver reliabillity (kappa) was 0.70 and intraobserver reliability (kappa) was 0.51 and 0.67. Before hormone therapy, factors related to decreased mammographic density were age and number of full term pregnancies (p<0.05). After one year of hormone therapy, body fat showed a significant increase (p<0.05), but in spite of this, increased mammographic density induced by hormone therapy remained significantly high (p<0.05). Compared with Group II, Group I showed a significant increase in mammographic density (p<0.05). In Group I, mammographic density increased from P2 to DY pattern in two cases, but there was no such change in Group II. The increase of mammographic density seen in Group II was much more significant statistically than that seen in Group I. The mammograms of women who have undergone continuous combined hormone therapy should therefore be interpreted very cautiously

  18. Role of Computer Aided Diagnosis (CAD in the detection of pulmonary nodules on 64 row multi detector computed tomography

    Directory of Open Access Journals (Sweden)

    K Prakashini

    2016-01-01

    Full Text Available Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2% and 202 (91.4% by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4% and nodules in hilar (100% and central (96.5% location when compared to RAD′s performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD′s performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  19. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    Science.gov (United States)

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  20. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006 - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collabora- tion avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  1. Quality Control and Dosimetry in Mammographic Units in Greece

    Energy Technology Data Exchange (ETDEWEB)

    Flioni-Vysa, A; Xenofos, S; Stamatelatos, E; Georgolopoulou, P [Department of Medical Physics, Saint Savvas Hospital, 171 Alexandras Avenue, Athens 115 22, (Greece)

    1994-12-31

    Quality control measurements have been carried out on 29 mammographic units. It was found that a large percentage of users obtained Optical Densities outside the recommended values. Resolution under routine conditions was below the limit of 14 lp/mm in about 50% of the units. The skin entrance dose was in a few cases in excess of 10 micro Gray, but the mean value was well below this upper limit. Analysis of the results obtained has indicated that proper calibration of kilo voltage panel indications and automatic exposure control systems is of outmost importance and should be performed regularly. (authors). 11 refs, 2 figs 3 tabs.

  2. Mammographic and sonographic features of fat necrosis of the breast

    International Nuclear Information System (INIS)

    Upadhyaya, Vidya S; Uppoor, Raghuraj; Shetty, Lathika

    2013-01-01

    Imaging features of fat necrosis vary depending on its stage of evolution and can mimic malignancy in late stages. Imaging may suffice to differentiate fat necrosis in the early stages from malignancy and thus avoid unnecessary biopsy. In this pictorial essay, we present combination of benign features in mammography and/or ultrasonography (USG) that can lead to imaging diagnosis of fat necrosis. The follow-up imaging features of fat necrosis which mirror its pathophysiological evolution have also been demonstrated. To summarize, in the appropriate clinical setting, no mammographic features suspicious for malignancy should be present. When the typical mammographic features are not present, USG can aid with the diagnosis and follow up USG can confirm it

  3. Mammographic profiles of women with symptomatic breast diseases ...

    African Journals Online (AJOL)

    Methods: This was a prospective descriptive analytical study of women with symptomatic breast diseases who had mammography between January 2012 and December 2016 at our health facilities. Data sheet was developed to record the patients' biodata, indication for referral, and mammographic findings. Results: During ...

  4. Usefulness of the CAD System for Detecting Pulmonary Nodule in Real Clinical Practice

    International Nuclear Information System (INIS)

    Song, Kyoung Doo; Chung, Myung Jin; Kim, Hee Cheol; Lee, Kyung Soo; Jeong, Sun Young

    2011-01-01

    We wanted to evaluate the usefulness of the computer-aided detection (CAD) system for detecting pulmonary nodules in real clinical practice by using the CT images. Our Institutional Review Board approved our retrospective study with a waiver of informed consent. This study included 166 CT examinations that were performed for the evaluation of pulmonary metastasis in 166 patients with colorectal cancer. All the CT examinations were interpreted by radiologists and they were also evaluated by the CAD system. All the nodules detected by the CAD system were evaluated with regard to whether or not they were true nodules, and they were classified into micro nodules (MN, diameter < 4 mm) and significant nodules (SN, 4 ≤ diameter ≤ 10 mm). The radiologic reports and CAD results were compared. The CAD system helped detect 426 nodules: 115 (27%) of the 426 nodules were classified as true nodules and 35 (30%) of the 115 nodules were SNs, and 83 (72%) of the 115 were not mentioned in the radiologists' reports and three (4%) of the 83 nodules were non-calcified SNs. One of three non-calcified SNs was confirmed as a metastatic nodule. According to the radiologists' reports, 60 true nodules were detected, and 28 of the 60 were not detected by the CAD system. Although the CAD system missed many SNs that are detected by radiologists, it helps detect additional nodules that are missed by the radiologists in real clinical practice. Therefore, the CAD system can be useful to support a radiologist's detection performance

  5. Combining different views of mammographic texture resemblance (MTR) marker of breast cancer risk

    DEFF Research Database (Denmark)

    Sun, S.; Karemore, Gopal; Chernoff, Konstantin

    the subsequent 4 years whereas 245 cases had a diagnosis 2-4 years post mammography. We employed the MTR supervised texture learning framework to perform risk evaluation from a single mammography view. In the framework 20,000 pixels were sampled and classified by a kNN pixel classifier. A feature selection step......PURPOSE Mammographic density is a well established breast cancer risk factor. Texture analysis in terms of the Mammographoc Texture Resemblance (MTR) marker has recently shown to add to risk segregation. Hitherto only single view MTR analysis has been performed. Standard mammography examinations...

  6. Fra form-Z til AutoCad

    DEFF Research Database (Denmark)

    Jensen, Henrik

    2003-01-01

    Dette kursus er lavet for at forberede de studerende til deres tegnestuepraktik, og dets indhold er planlagt i samarbejde med tegnestuerne. I 2003 var form-Z Arkitektskolens grundlæggende CAD-program; men på tegnestuerne arbejde man med AutoCad. Kurset er opbygget over CAD Clasic skabelonen (se min...

  7. TEACHING CAD PROGRAMMING TO ARCHITECTURE STUDENTS

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Caffarena CELANI

    2008-11-01

    Full Text Available The objective of this paper is to discuss the relevance of including the discipline of computer programming in the architectural curriculum. To do so I start by explaining how computer programming has been applied in other educational contexts with pedagogical success, describing Seymour Papert's principles. After that, I summarize the historical development of CAD and provide three historical examples of educational applications of computer programming in architecture, followed by a contemporary case that I find of particular relevance. Next, I propose a methodology for teaching programming for architects that aims at improving the quality of designs by making their concepts more explicit. This methodology is based on my own experience teaching computer programming for architecture students at undergraduate and graduate levels at the State University of Campinas, Brazil. The paper ends with a discussion about the role of programming nowadays, when most CAD software are user-friendly and do not require any knowledge of programming for improving performance. I conclude that the introduction of programming in the CAD curriculum within a proper conceptual framework may transform the concept of architectural education. Key-words: Computer programming; computer-aided design; architectural education.

  8. Mammographic and sonographic spectrum of non-puerperal mastitis

    NARCIS (Netherlands)

    M.H. Lequin (Maarten); J. van Spengler (J.); R. van Pel; C.H.J. van Eijck (Casper); H. van Overhagen (H.)

    1995-01-01

    textabstractThe goal of this study was to explore possible specific mammographic and sonographic features in women with non-puerperal mastitis (NPM), in order to make an accurate diagnosis and prevent unnecessary surgical procedures. From a group of 93 patients with NPM diagnosed between 1987 and

  9. Mammographic feature enhancement by multiscale analysis

    International Nuclear Information System (INIS)

    Laine, A.F.; Schuler, S.; Fan, J.; Huda, W.

    1994-01-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis by overcomplete multiresolution representations. The authors show that efficient representations may be identified within a continuum of scale-space and used to enhance features of importance to mammography. Methods of contrast enhancement are described based on three overcomplete multiscale representations: (1) the dyadic wavelet transform (separable), (2) the var-phi-transform (nonseparable, nonorthogonal), and (3) the hexagonal wavelet transform (nonseparable). Multiscale edges identified within distinct levels of transform space provide local support for image enhancement. Mammograms are reconstructed from wavelet coefficients modified at one or more levels by local and global nonlinear operators. In each case, edges and gain parameters are identified adaptively by a measure of energy within each level of scale-space. The authors show quantitatively that transform coefficients, modified by adaptive nonlinear operators, can make more obvious unseen or barely seen features of mammography without requiring additional radiation. The results are compared with traditional image enhancement techniques by measuring the local contrast of known mammographic features. The authors demonstrate that features extracted from multiresolution representations can provide an adaptive mechanism for accomplishing local contrast enhancement. By improving the visualization of breast pathology, they can improve chances of early detection while requiring less time to evaluate mammograms for most patients

  10. Initial CAD investigations for NET

    International Nuclear Information System (INIS)

    Katz, F.; Leinemann, K.; Ludwig, A.; Marek, U.; Olbrich, W.; Schlechtendahl, E.G.

    1985-11-01

    This report summarizes the work done under contract no. 164/84-7/FU-D-/NET between the Commission of the European Communities and KfK during the period from June 1, 1984, through May 31, 1985. The following topics are covered in this report: Initial modelling of NET version NET2A, CAD system extension for remote handling studies, analysis of the CAD information structure, work related to the transfer of CAD information between KfK and the NET team. (orig.) [de

  11. Computer-aided diagnosis of mammographic masses using geometric verification-based image retrieval

    Science.gov (United States)

    Li, Qingliang; Shi, Weili; Yang, Huamin; Zhang, Huimao; Li, Guoxin; Chen, Tao; Mori, Kensaku; Jiang, Zhengang

    2017-03-01

    Computer-Aided Diagnosis of masses in mammograms is an important indicator of breast cancer. The use of retrieval systems in breast examination is increasing gradually. In this respect, the method of exploiting the vocabulary tree framework and the inverted file in the mammographic masse retrieval have been proved high accuracy and excellent scalability. However it just considered the features in each image as a visual word and had ignored the spatial configurations of features. It greatly affect the retrieval performance. To overcome this drawback, we introduce the geometric verification method to retrieval in mammographic masses. First of all, we obtain corresponding match features based on the vocabulary tree framework and the inverted file. After that, we grasps the main point of local similarity characteristic of deformations in the local regions by constructing the circle regions of corresponding pairs. Meanwhile we segment the circle to express the geometric relationship of local matches in the area and generate the spatial encoding strictly. Finally we judge whether the matched features are correct or not, based on verifying the all spatial encoding are whether satisfied the geometric consistency. Experiments show the promising results of our approach.

  12. Mammographic density measurements are not affected by mammography system.

    Science.gov (United States)

    Damases, Christine N; Brennan, Patrick C; McEntee, Mark F

    2015-01-01

    Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman's density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists' visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer's equipment affects a woman's MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation ([Formula: see text]; [Formula: see text]), while the VDG ([Formula: see text]; [Formula: see text]) and AvBD% ([Formula: see text]; [Formula: see text]) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS ([Formula: see text]; [Formula: see text]), however, the systems demonstrated an almost perfect agreement for VDG ([Formula: see text]; [Formula: see text]).

  13. Toward clinically usable CAD for lung cancer screening with computed tomography

    International Nuclear Information System (INIS)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R.

    2014-01-01

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  14. Toward clinically usable CAD for lung cancer screening with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R. [David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, CA (United States)

    2014-11-15

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  15. Investigation of support vector machine for the detection of architectural distortion in mammographic images

    International Nuclear Information System (INIS)

    Guo, Q; Shao, J; Ruiz, V

    2005-01-01

    This paper investigates detection of architectural distortion in mammographic images using support vector machine. Hausdorff dimension is used to characterise the texture feature of mammographic images. Support vector machine, a learning machine based on statistical learning theory, is trained through supervised learning to detect architectural distortion. Compared to the Radial Basis Function neural networks, SVM produced more accurate classification results in distinguishing architectural distortion abnormality from normal breast parenchyma

  16. Investigation of support vector machine for the detection of architectural distortion in mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Q [Department of Cybernetics, University of Reading, Reading RG6 6AY (United Kingdom); Shao, J [Department of Electronics, University of Kent at Canterbury, Kent CT2 7NT (United Kingdom); Ruiz, V [Department of Cybernetics, University of Reading, Reading RG6 6AY (United Kingdom)

    2005-01-01

    This paper investigates detection of architectural distortion in mammographic images using support vector machine. Hausdorff dimension is used to characterise the texture feature of mammographic images. Support vector machine, a learning machine based on statistical learning theory, is trained through supervised learning to detect architectural distortion. Compared to the Radial Basis Function neural networks, SVM produced more accurate classification results in distinguishing architectural distortion abnormality from normal breast parenchyma.

  17. Body mass index and participation in organized mammographic screening

    DEFF Research Database (Denmark)

    Hellmann, Sophie Sell; Njor, Sisse Helle; Lynge, Elsebeth

    2015-01-01

    BACKGROUND: Breast cancer is the leading cancer among women, and early diagnosis is essential for future prognosis. Evidence from mainly cross-sectional US studies with self-reported exposure and outcome found positive association of body mass index (BMI) with non-participation in mammographic...... with normal weight. This association was limited to postmenopausal women (Wald test p = 0.08), with enhanced non-participation in underweight (2.83: 1.52-5.27) and obese women of class II and III (1.84: 1.15-2.95; 2.47: 1.20-5.06) as compared to normal weight postmenopausal women. There was no effect...... modification by HT, previous screening participation, or morbidities, besides suggestive evidence of enhanced non-participation in diabetic overweight and obese women. CONCLUSIONS: Underweight and very obese postmenopausal women were significantly less likely to participate in mammographic screening than women...

  18. Mammographic compression in Asian women.

    Science.gov (United States)

    Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong

    2017-01-01

    To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (pAsian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.

  19. Mammographic classification of breast lesions amongst women in ...

    African Journals Online (AJOL)

    Objectives: The study was to classify lesions identified on mammograms using Breast Imaging Reporting and Data System (BIRADS) grading method. This was in view of ascertaining the rate of occurrence of breast malignancy of the studied population. Methods: A retrospective cohort study of 416 mammographic reports of ...

  20. Numerical Analysis of Turbulent Flow around Tube Bundle by Applying CAD Best Practice Guideline

    International Nuclear Information System (INIS)

    Lee, Gong Hee; Bang, Young Seok; Woo, Sweng Woong; Cheng, Ae Ju

    2013-01-01

    In this study, the numerical analysis of a turbulent flow around both a staggered and an incline tube bundle was conducted using Annoys Cfx V. 13, a commercial CAD software. The flow was assumed to be steady, incompressible, and isothermal. According to the CAD Best Practice Guideline, the sensitivity study for grid size, accuracy of the discretization scheme for convection term, and turbulence model was conducted, and its result was compared with the experimental data to estimate the applicability of the CAD Best Practice Guideline. It was concluded that the CAD Best Practice Guideline did not always guarantee an improvement in the prediction performance of the commercial CAD software in the field of tube bundle flow

  1. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  2. Suunnitteluautomaatio CAD-ohjelmissa

    OpenAIRE

    Anttila, Juho

    2010-01-01

    Tässä työssä tutkittiin suunnitteluautomaation mahdollisuuksia cad-ohjelmissa. Työtä varten perehdyttiin useampaan cad-ohjelmaan ja tehtiin suurehko automaatti Vertex G4 alustalle, jonka kokemuksiin työn pohdinta pitkälti perustuu. Työ etenee yleisestä työkalujen esittelystä automatisoinnin teoriaan. Teoriassa pohditaan erilaisia tapoja ja tasoja miten automatisointia voidaan toteuttaa. Työn aihe oli kiinnostava, koska aiheesta on tehty melko vähän teoksia. Teoriapohdiskelun ohella esitettii...

  3. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006

    - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium, Bât 593 Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collaboration avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  4. Chairside CAD/CAM materials. Part 3: Cyclic fatigue parameters and lifetime predictions.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Valladares, Diana; Petschelt, Anselm; Lohbauer, Ulrich

    2018-06-01

    Chemical and mechanical degradation play a key role on the lifetime of dental restorative materials. Therefore, prediction of their long-term performance in the oral environment should base on fatigue, rather than inert strength data, as commonly observed in the dental material's field. The objective of the present study was to provide mechanistic fatigue parameters of current dental CAD/CAM materials under cyclic biaxial flexure and assess their suitability in predicting clinical fracture behaviors. Eight CAD/CAM materials, including polycrystalline zirconia (IPS e.max ZirCAD), reinforced glasses (Vitablocs Mark II, IPS Empress CAD), glass-ceramics (IPS e.max CAD, Suprinity PC, Celtra Duo), as well as hybrid materials (Enamic, Lava Ultimate) were evaluated. Rectangular plates (12×12×1.2mm 3 ) with highly polished surfaces were prepared and tested in biaxial cyclic fatigue in water until fracture using the Ball-on-Three-Balls (B3B) test. Cyclic fatigue parameters n and A* were obtained from the lifetime data for each material and further used to build SPT diagrams. The latter were used to compare in-vitro with in-vivo fracture distributions for IPS e.max CAD and IPS Empress CAD. Susceptibility to subcritical crack growth under cyclic loading was observed for all materials, being more severe (n≤20) in lithium-based glass-ceramics and Vitablocs Mark II. Strength degradations of 40% up to 60% were predicted after only 1 year of service. Threshold stress intensity factors (K th ) representing the onset of subcritical crack growth (SCG), were estimated to lie in the range of 0.37-0.44 of K Ic for the lithium-based glass-ceramics and Vitablocs Mark II and between 0.51-0.59 of K Ic for the other materials. Failure distributions associated with mechanistic estimations of strength degradation in-vitro showed to be useful in interpreting failure behavior in-vivo. The parameter K th stood out as a better predictor of clinical performance in detriment to the SCG n

  5. Optimizing Case-based detection performance in a multiview CAD system for mammography

    NARCIS (Netherlands)

    Samulski, M.; Karssemeijer, N.

    2011-01-01

    When reading mammograms, radiologists combine information from multiple views to detect abnormalities. Most computer-aided detection (CAD) systems, however, use primitive methods for inclusion of multiview context or analyze each view independently. In previous research it was found that in

  6. Association of mammographic image feature change and an increasing risk trend of developing breast cancer: an assessment

    Science.gov (United States)

    Tan, Maxine; Leader, Joseph K.; Liu, Hong; Zheng, Bin

    2015-03-01

    We recently investigated a new mammographic image feature based risk factor to predict near-term breast cancer risk after a woman has a negative mammographic screening. We hypothesized that unlike the conventional epidemiology-based long-term (or lifetime) risk factors, the mammographic image feature based risk factor value will increase as the time lag between the negative and positive mammography screening decreases. The purpose of this study is to test this hypothesis. From a large and diverse full-field digital mammography (FFDM) image database with 1278 cases, we collected all available sequential FFDM examinations for each case including the "current" and 1 to 3 most recently "prior" examinations. All "prior" examinations were interpreted negative, and "current" ones were either malignant or recalled negative/benign. We computed 92 global mammographic texture and density based features, and included three clinical risk factors (woman's age, family history and subjective breast density BIRADS ratings). On this initial feature set, we applied a fast and accurate Sequential Forward Floating Selection (SFFS) feature selection algorithm to reduce feature dimensionality. The features computed on both mammographic views were individually/ separately trained using two artificial neural network (ANN) classifiers. The classification scores of the two ANNs were then merged with a sequential ANN. The results show that the maximum adjusted odds ratios were 5.59, 7.98, and 15.77 for using the 3rd, 2nd, and 1st "prior" FFDM examinations, respectively, which demonstrates a higher association of mammographic image feature change and an increasing risk trend of developing breast cancer in the near-term after a negative screening.

  7. Transcriptome-wide identification and characterization of CAD isoforms specific for podophyllotoxin biosynthesis from Podophyllum hexandrum.

    Science.gov (United States)

    Bhattacharyya, Dipto; Hazra, Saptarshi; Banerjee, Anindyajit; Datta, Riddhi; Kumar, Deepak; Chakrabarti, Saikat; Chattopadhyay, Sharmila

    2016-09-01

    Podophyllotoxin (ptox) is a therapeutically important lignan derived from Podophyllum hexandrum and is used as a precursor for the synthesis of anticancer drugs etoposide, teniposide and etopophose. In spite of its enormous economic significance, genomic information on this endangered medicinal herb is scarce. We have performed de novo transcriptome analysis of methyl jasmonate (MeJA)-treated P. hexandrum cell cultures exhibiting enhanced ptox accumulation. The results revealed the maximum up-regulation of several isoforms of cinnamyl alcohol dehydrogenase (CAD). CAD catalyzes the synthesis of coniferyl alcohol and sinapyl alcohol from coniferaldehyde (CAld) and sinapaldehyde respectively. Coniferyl alcohol can produce both lignin and lignan while sinapyl alcohol produces only lignin. To isolate the CAD isoforms favoring ptox, we deduced full length cDNA sequences of four CAD isoforms: PhCAD1, PhCAD2, PhCAD3 and PhCAD4 from the contigs of the transcriptome data. In vitro enzyme assays indicated a higher affinity for CAld over sinapaldehyde for each isoform. In silico molecular docking analyses also suggested that PhCAD3 has a higher binding preference with CAld over sinapaldehyde, followed by PhCAD4, PhCAD2, and PhCAD1, respectively. The transgenic cell cultures overexpressing these isoforms independently revealed that PhCAD3 favored the maximum accumulation of ptox as compared to lignin followed by PhCAD4 and PhCAD2, whereas, PhCAD1 favored both equally. Together, our study reveals transcriptome-wide identification and characterization of ptox specific CAD isoforms from P. hexandrum. It provides a useful resource for future research not only on the ptox biosynthetic pathway but on overall P. hexandrum, an endangered medicinal herb with immense therapeutic importance.

  8. DESIGN REVIEW OF CAD MODELS USING A NUI LEAP MOTION SENSOR

    Directory of Open Access Journals (Sweden)

    GÎRBACIA Florin

    2015-06-01

    Full Text Available Natural User Interfaces (NUI is a relatively new area of research that aims to develop humancomputer interfaces, natural and intuitive, using voice commands, hand movements and gesture recognition, similar to communication between people which also implies body language and gestures. In this paper is presented a natural designed workspace which acquires the user's motion using a Leap Motion sensor and visualizes the CAD models using a CAVE-like 3D visualisation system. The user can modify complex CAD models using bimanual gesture commands in a 3D virtual environment. The developed bimanual gestures for rotate, pan, zoom and explode are presented. From the conducted experiments is established that Leap Motion NUI sensor provides an intuitive tool for design review of CAD models, performed even by users with no experience in CAD systems and virtual environments.

  9. 64006 CAD i Byggesektoren. Grundkursus

    DEFF Research Database (Denmark)

    Borchersen, Egil

    1998-01-01

    Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes.......Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes....

  10. Should breast MRI be performed with adjustment for the phase in patients’ menstrual cycle? Correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2012-01-01

    Purpose: The purpose of this study was to assess the correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle. Material and methods: The background enhancement of bilateral breast MRI and the breast density of mammography in 146 consecutive women without adjusting for the phase in patients’ menstrual cycle were reviewed. The breast density was classified into four categories according to the American College of Radiology the Breast Imaging Reporting and Data System lexicon. The background enhancement was classified into four categories: minimal, mild, moderate, and marked. The correlations of mammographic breast density as well as age with background enhancement on breast MRI were examined. Results: There was a significant correlation between mammographic breast density and background enhancement (p = 0.011). All nine cases with almost completely fat mammographic breast density showed minimal (78%) or mild (12%) background enhancement on breast MRI. There was a significant inverse correlation between age and background enhancement (p < 0.0001). Younger patients with dense breasts were more likely to demonstrate moderate/marked background enhancement. Conclusion: When no adjusting for the phase in patients’ menstrual cycle, a significant correlation was observed between background enhancement and mammographic density. A significant inverse correlation was also observed between age and background enhancement.

  11. Novel Associations between Common Breast Cancer Susceptibility Variants and Risk-Predicting Mammographic Density Measures

    OpenAIRE

    Stone, Jennifer; Thompson, Deborah J.; dos-Santos-Silva, Isabel; Scott, Christopher; Tamimi, Rulla M.; Lindstrom, Sara; Kraft, Peter; Hazra, Aditi; Li, Jingmei; Eriksson, Louise; Czene, Kamila; Hall, Per; Jensen, Matt; Cunningham, Julie; Olson, Janet E.

    2015-01-01

    Mammographic density measures adjusted for age and body mass index (BMI) are heritable predictors of breast cancer risk but few mammographic density-associated genetic variants have been identified. Using data for 10,727 women from two international consortia, we estimated associations between 77 common breast cancer susceptibility variants and absolute dense area, percent dense area and absolute non-dense area adjusted for study, age and BMI using mixed linear modeling. We found strong suppo...

  12. The Enzyme Activity and Substrate Specificity of Two Major Cinnamyl Alcohol Dehydrogenases in Sorghum (Sorghum bicolor), SbCAD2 and SbCAD4.

    Science.gov (United States)

    Jun, Se-Young; Walker, Alexander M; Kim, Hoon; Ralph, John; Vermerris, Wilfred; Sattler, Scott E; Kang, ChulHee

    2017-08-01

    Cinnamyl alcohol dehydrogenase (CAD) catalyzes the final step in monolignol biosynthesis, reducing sinapaldehyde, coniferaldehyde, and p -coumaraldehyde to their corresponding alcohols in an NADPH-dependent manner. Because of its terminal location in monolignol biosynthesis, the variation in substrate specificity and activity of CAD can result in significant changes in overall composition and amount of lignin. Our in-depth characterization of two major CAD isoforms, SbCAD2 (Brown midrib 6 [bmr6]) and SbCAD4, in lignifying tissues of sorghum ( Sorghum bicolor ), a strategic plant for generating renewable chemicals and fuels, indicates their similarity in both structure and activity to Arabidopsis ( Arabidopsis thaliana ) CAD5 and Populus tremuloides sinapyl alcohol dehydrogenase, respectively. This first crystal structure of a monocot CAD combined with enzyme kinetic data and a catalytic model supported by site-directed mutagenesis allows full comparison with dicot CADs and elucidates the potential signature sequence for their substrate specificity and activity. The L119W/G301F-SbCAD4 double mutant displayed its substrate preference in the order coniferaldehyde > p -coumaraldehyde > sinapaldehyde, with higher catalytic efficiency than that of both wild-type SbCAD4 and SbCAD2. As SbCAD4 is the only major CAD isoform in bmr6 mutants, replacing SbCAD4 with L119W/G301F-SbCAD4 in bmr6 plants could produce a phenotype that is more amenable to biomass processing. © 2017 American Society of Plant Biologists. All Rights Reserved.

  13. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  14. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  15. Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD/CAM Materials.

    Science.gov (United States)

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2018-03-06

    A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p 0.05). Deviation pattern for

  16. Applying a new unequally weighted feature fusion method to improve CAD performance of classifying breast lesions

    Science.gov (United States)

    Zargari Khuzani, Abolfazl; Danala, Gopichandh; Heidari, Morteza; Du, Yue; Mashhadi, Najmeh; Qiu, Yuchen; Zheng, Bin

    2018-02-01

    Higher recall rates are a major challenge in mammography screening. Thus, developing computer-aided diagnosis (CAD) scheme to classify between malignant and benign breast lesions can play an important role to improve efficacy of mammography screening. Objective of this study is to develop and test a unique image feature fusion framework to improve performance in classifying suspicious mass-like breast lesions depicting on mammograms. The image dataset consists of 302 suspicious masses detected on both craniocaudal and mediolateral-oblique view images. Amongst them, 151 were malignant and 151 were benign. The study consists of following 3 image processing and feature analysis steps. First, an adaptive region growing segmentation algorithm was used to automatically segment mass regions. Second, a set of 70 image features related to spatial and frequency characteristics of mass regions were initially computed. Third, a generalized linear regression model (GLM) based machine learning classifier combined with a bat optimization algorithm was used to optimally fuse the selected image features based on predefined assessment performance index. An area under ROC curve (AUC) with was used as a performance assessment index. Applying CAD scheme to the testing dataset, AUC was 0.75+/-0.04, which was significantly higher than using a single best feature (AUC=0.69+/-0.05) or the classifier with equally weighted features (AUC=0.73+/-0.05). This study demonstrated that comparing to the conventional equal-weighted approach, using an unequal-weighted feature fusion approach had potential to significantly improve accuracy in classifying between malignant and benign breast masses.

  17. Volumetric mammographic density: heritability and association with breast cancer susceptibility loci.

    Science.gov (United States)

    Brand, Judith S; Humphreys, Keith; Thompson, Deborah J; Li, Jingmei; Eriksson, Mikael; Hall, Per; Czene, Kamila

    2014-12-01

    Mammographic density is a strong heritable trait, but data on its genetic component are limited to area-based and qualitative measures. We studied the heritability of volumetric mammographic density ascertained by a fully-automated method and the association with breast cancer susceptibility loci. Heritability of volumetric mammographic density was estimated with a variance component model in a sib-pair sample (N pairs = 955) of a Swedish screening based cohort. Associations with 82 established breast cancer loci were assessed in an independent sample of the same cohort (N = 4025 unrelated women) using linear models, adjusting for age, body mass index, and menopausal status. All tests were two-sided, except for heritability analyses where one-sided tests were used. After multivariable adjustment, heritability estimates (standard error) for percent dense volume, absolute dense volume, and absolute nondense volume were 0.63 (0.06) and 0.43 (0.06) and 0.61 (0.06), respectively (all P associated with rs10995190 (ZNF365; P = 9.0 × 10(-6) and 8.9 × 10(-7), respectively) and rs9485372 (TAB2; P = 1.8 × 10(-5) and 1.8 × 10(-3), respectively). We also observed associations of rs9383938 (ESR1) and rs2046210 (ESR1) with the absolute dense volume (P = 2.6 × 10(-4) and 4.6 × 10(-4), respectively), and rs6001930 (MLK1) and rs17356907 (NTN4) with the absolute nondense volume (P = 6.7 × 10(-6) and 8.4 × 10(-5), respectively). Our results support the high heritability of mammographic density, though estimates are weaker for absolute than percent dense volume. We also demonstrate that the shared genetic component with breast cancer is not restricted to dense tissues only. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Viewing CAD Drawings on the Internet

    Science.gov (United States)

    Schwendau, Mark

    2004-01-01

    Computer aided design (CAD) has been producing 3-D models for years. AutoCAD software is frequently used to create sophisticated 3-D models. These CAD files can be exported as 3DS files for import into Autodesk's 3-D Studio Viz. In this program, the user can render and modify the 3-D model before exporting it out as a WRL (world file hyperlinked)…

  19. Male breast disease: clinical, mammographic, and ultrasonographic features

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-01-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination

  20. Male breast disease: clinical, mammographic, and ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Guenhan-Bilgen, Isil E-mail: isilbilgen@hotmail.com; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-09-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination.

  1. CAD/CAM-assisted breast reconstruction

    International Nuclear Information System (INIS)

    Melchels, Ferry; Hutmacher, Dietmar Werner; Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten; Warne, David; Barry, Mark; Ong, Fook Rhu; Chong, Woon Shin

    2011-01-01

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  2. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network.

    Science.gov (United States)

    Albero, Alberto; Pascual, Agustín; Camps, Isabel; Grau-Benitez, María

    2015-10-01

    The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems. In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured. IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials. The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness.

  3. Computing Mass Properties From AutoCAD

    Science.gov (United States)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  4. AutoCAD platform customization autolisp

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Customize and personalize programs built on the AutoCAD platform AutoLISP is the key to unlocking the secrets of a more streamlined experience using industry leading software programs like AutoCAD, Civil 3D, Plant 3D, and more. AutoCAD Platform Customization: AutoLISP provides real-world examples that show you how to do everything from modifying graphical objects and reading and setting system variables to communicating with external programs. It also features a resources appendix and downloadable datasets and customization examples-tools that ensure swift and easy adoption. Find out how to r

  5. Line Generalization and AutoCAD Map

    Directory of Open Access Journals (Sweden)

    Nada Vučetić

    2001-01-01

    Full Text Available The paper offers the results of original research made on the application of AutoCAD Map in line generalisation. The differences and similarities have been found out between the Douglas-Peucker method and the method of line simplification that is incorporated in AutoCAD Map. There have been also the inaccuracies found out in AutoCAD Map manual relating to the issues of buffer width and tolerance, and the line width before and after simplification. The paper gives recommendations about pseudo nodes dissolving. It has been noticed that AutoCAD Map simplification method is not independent of the order of points. The application of the method is illustrated by an example of coastal line of Istria.

  6. Overdiagnosis in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Puliti, Donella; Duffy, Stephen W; Miccinesi, Guido

    2012-01-01

    Overdiagnosis, the detection through screening of a breast cancer that would never have been identified in the lifetime of the woman, is an adverse outcome of screening. We aimed to determine an estimate range for overdiagnosis of breast cancer in European mammographic service screening programmes....

  7. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  8. Radiologic-pathologic correlation of the mammographic findings retrospectively detected in inflammatory breast cancer. Usefulness in clinical practice

    International Nuclear Information System (INIS)

    Caumo, F.; Manfrin, E.; Bonetti, F.; Pinali, L.; Procacci, C.

    2002-01-01

    Background. The aim of this study was to describe the clinical, mammographical and pathological characteristics of inflammatory carcinoma. Patients and methods. Clinical, mammographical and histological sections of twenty-two women (age range 28-60 years) were reviewed. The examinations had been performed over a period of four years. Results. The clinical findings were: erythema, edema, thickening of the skin and breast heat in ten patients; palpable mass in nine patients; nipple discharge in one patient; absent in two patients. Pathological findings were: tumor emboli in the dermal lymphatics in eight patients; tumor emboli in the vessels in ten patients; tumor emboli both in the dermal lymphatics and in the vessels in four patients. The radiologic findings were: skin thickening, trabecular thickening and blurring of structure in ten patients (common presentation); mass in nine patients; malignant-type calcifications in two patients (uncommon presentation); absent in one patient. The follow-up examination (eighteen months) detected that only one patient with common presentation of inflammatory carcinoma had no local or systemic recurrence against eight patients with uncommon presentation. Conclusions. The clinical and mammographical aspects, which suggest the presence of an inflammatory carcinoma, occur only in 45.4% of the patients. The radiological aspect seems to correlate with the different prognosis of the tumour, resulting in a better prognosis in those with an uncommon aspect. (author)

  9. BUILDING A PERGOLA IN CAD SYSTEMS

    Directory of Open Access Journals (Sweden)

    PRUNA Liviu

    2017-05-01

    Full Text Available In this paper the authors present a study and the conclusions they reached, regarding the possibility to automatically representing a pergola, when a CAD system is used. Also, a computer program, made by the authors is presented. This software was named Pergola and it offer the opportunity to sketch a pergola which cover a rectangular or circular area, when using the AutoCAD Architecture or AutoCAD computer program.

  10. Overview of the breast cancer and mammographic status in Asia and in Japan

    International Nuclear Information System (INIS)

    Endo, Tokiko

    2017-01-01

    Breast cancer is the top cancer in women both in the most Western and Asian countries. The incidence of the breast cancer is lower in Asia than in the western countries, but, is increasing due to increase life expectancy, increase urbanization and adoption of western life styles. Mammography screening is the only method that has proved to be effective and cost-effective. In Japan, the mammographic breast cancer screening was started in 2004, and quality control has been done by the Japan Central Organization on Quality Assurance of Breast Cancer Screening, which is consisted with nine major societies concerning the breast cancer diagnosis and treatment. The Japanese Society of Radiological Technology and the Japan Society of Medical Physics are the members of this organization and play impotent roles in mammographic quality control. The main activities of this organization are the education for radiological technicians and interpreters and the insurance the mammographic facilities meet radiation dose and image quality standard. I'll introduce the state of the breast cancer and the efforts for breast cancer screening in Asian countries and in Japan

  11. Efficiency of Lu2SiO5:Ce (LSO) powder phosphor as X-ray to light converter under mammographic imaging conditions

    International Nuclear Information System (INIS)

    David, S.; Michail, C.; Valais, I.; Nikolopoulos, D.; Liaparinos, P.; Kalivas, N.; Kalatzis, I.; Toutountzis, A.; Efthimiou, N.; Loudos, G.; Sianoudis, I.; Cavouras, D.; Dimitropoulos, N.; Nomicos, C.D.; Kandarakis, I.; Panayiotakis, G.S.

    2007-01-01

    The aim of the present study was to examine the light emission efficiency of Lu 2 SiO 5 :Ce (LSO) powder scintillator under X-ray mammographic imaging conditions. Powder LSO scintillator has never been used in X-ray imaging. For the purposes of the present study, a 25 mg/cm 2 thick scintillating screen was prepared in our laboratory, by sedimentation of Lu 2 SiO 5 :Ce powder. Absolute luminescence efficiency measurements were performed within the range of X-ray tube voltages (22-49 kVp) used in mammographic applications. Parameters related to X-ray detection, i.e. the energy absorption efficiency (EAE) and the quantum detection efficiency (QDE) were calculated. A theoretical model, describing radiation and light transfer, was employed to fit experimental data and to estimate values of the intrinsic conversion efficiency and the light attenuation coefficients of the screen. The spectral compatibility of the LSO powder scintillator to mammographic X-ray films and to various electronic optical detectors was determined by performing light emission spectrum measurements and by taking into account the spectral sensitivity of the optical detectors. Results in the voltage range used in mammography showed that Lu 2 SiO 5 :Ce powder scintillator has approximately 10% higher values of QDE and 4.5% higher values of EAE than Gd 2 O 2 S:Tb

  12. Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD).

    Science.gov (United States)

    Balleyguier, Corinne; Arfi-Rouche, Julia; Levy, Laurent; Toubiana, Patrick R; Cohen-Scali, Franck; Toledano, Alicia Y; Boyer, Bruno

    2017-12-01

    Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0

  13. Construction of mammographic examination process ontology using bottom-up hierarchical task analysis.

    Science.gov (United States)

    Yagahara, Ayako; Yokooka, Yuki; Jiang, Guoqian; Tsuji, Shintarou; Fukuda, Akihisa; Nishimoto, Naoki; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2018-03-01

    Describing complex mammography examination processes is important for improving the quality of mammograms. It is often difficult for experienced radiologic technologists to explain the process because their techniques depend on their experience and intuition. In our previous study, we analyzed the process using a new bottom-up hierarchical task analysis and identified key components of the process. Leveraging the results of the previous study, the purpose of this study was to construct a mammographic examination process ontology to formally describe the relationships between the process and image evaluation criteria to improve the quality of mammograms. First, we identified and created root classes: task, plan, and clinical image evaluation (CIE). Second, we described an "is-a" relation referring to the result of the previous study and the structure of the CIE. Third, the procedural steps in the ontology were described using the new properties: "isPerformedBefore," "isPerformedAfter," and "isPerformedAfterIfNecessary." Finally, the relationships between tasks and CIEs were described using the "isAffectedBy" property to represent the influence of the process on image quality. In total, there were 219 classes in the ontology. By introducing new properties related to the process flow, a sophisticated mammography examination process could be visualized. In relationships between tasks and CIEs, it became clear that the tasks affecting the evaluation criteria related to positioning were greater in number than those for image quality. We developed a mammographic examination process ontology that makes knowledge explicit for a comprehensive mammography process. Our research will support education and help promote knowledge sharing about mammography examination expertise.

  14. CAD Skills Increased through Multicultural Design Project

    Science.gov (United States)

    Clemons, Stephanie

    2006-01-01

    This article discusses how students in a college-entry-level CAD course researched four generations of their family histories and documented cultural and symbolic influences within their family backgrounds. AutoCAD software was then used to manipulate those cultural and symbolic images to create the design for a multicultural area rug. AutoCAD was…

  15. The cinnamyl alcohol dehydrogenase (CAD gene family in flax (Linum usitatissimum L.: Insight from expression profiling of cads induced by elicitors in cultured flax cells

    Directory of Open Access Journals (Sweden)

    Eom Hee Seung

    2016-01-01

    Full Text Available Cinnamyl alcohol dehydrogenase (CAD is a key enzyme in the biosynthesis of lignin and lignans as it catalyzes the final step of monolignol biosynthesis, using NADPH as a cofactor. In higher plants, CAD is encoded by a multigene family consisting of three major classes. Based on the recently released flax (Linum usitatissimum L. whole-genome sequences, in this study we identified six CAD family genes that contain an ADH_N domain and an ADH_zinc_N domain, which suggests that the putative flax CADs (LuCADs are zinc-dependent alcohol dehydrogenases and members of the plant CAD family. In addition, expression analysis using quantitative real-time PCR revealed spatial variations in the expression of LuCADs in different organs. Comparative analysis between LuCAD enzymatic activity and LuCAD transcripts indicates that the variation of LuCAD enzymatic activities by elicitors is reflected by transcription of LuCADs in flax suspension-cultured cells. Taken together, our genome-wide analysis of CAD genes and the expression profiling of these genes provide valuable information for understanding the function of CADs, and will assist future studies on the physiological role of monolignols associated with plant defense.

  16. Automated effect-specific mammographic pattern measures

    DEFF Research Database (Denmark)

    Raundahl, Jakob; Loog, Marco; Pettersen, Paola

    2008-01-01

    We investigate the possibility to develop methodologies for assessing effect specific structural changes of the breast tissue using a general statistical machine learning framework. We present an approach of obtaining objective mammographic pattern measures quantifying a specific biological effect......, such as hormone replacement therapy (HRT). We compare results using this approach to using standard density measures. We show that the proposed method can quantify both age related effects and effects caused by HRT. Age effects are significantly detected by our method where standard methodologies fail...

  17. Benefit-risk evaluation of mammographic mass screening

    International Nuclear Information System (INIS)

    Sato, Nobuo; Ogura, Toshihiro

    1990-01-01

    This study evaluated the benefit-risk balance of mammography in mass screening by using survival rates from 3000 breast cancer patients at the Japanese Foundation for Cancer Research Institute Hospital. Because the number of participants in mammographic mass screening was small, asymptomatic patients with pathologically proven early breast cancer were categorized as the screenee group. Symptomatic patients were categorized as the patient group. Survival rates were compared in both the screenee and the patient groups. Based on the difference in areas of survival curves between screenees and patients, the ratio of person-year gain (PYG) to person-year lost (PYL) was obtained. The ratio of PYG to PYL was multiplied by the detection rate resulting from a particular screening program to obtain the benefit/risk ratio. The detection rate of nonpalpable breast cancer was 15 times higher in the screenee group than the patient group. Breast cancer was detected in 7 (0.85%) of 824 patients in the screenee group. Even when mammographic mass screening was started at the age of 30, the benefit of mammography was far superior to the risk. The number of participants in mass screening stratified by age may be required for the conclusion of the benefit-risk balance of mammography in mass screening. (N.K.)

  18. American College of Radiology Accreditation Program for mammographic screening sites: Physical evaluation criteria

    International Nuclear Information System (INIS)

    Hendrick, R.E.; Haus, A.G.; Hubbard, L.B.; Lasky, H.J.; McCrohan, J.; McLelland, R.; Rothenberg, L.N.; Tanner, R.L.; Zinninger, M.D.

    1987-01-01

    The American College of Radiology has initiated a program for the accreditation of mammographic screening sites, which includes evaluation by mail of image quality and average glandular breast dose. Image quality is evaluated by use of a specially designed phantom (a modified RMI 152D Mammographic Phantom) containing simulated microcalcifications, fibrils and masses. Average glandular dose to a simulated 4.5-cm-thick (50% glandular, 50% fat) compressed breast is evaluated by thermoluminescent dosimeter measurements of entrance exposure and half value layer. Standards for acceptable image quality and patient doses are presented and preliminary results of the accreditation program are discussed

  19. Development of CAD-Based Geometry Processing Module for a Monte Carlo Particle Transport Analysis Code

    International Nuclear Information System (INIS)

    Choi, Sung Hoon; Kwark, Min Su; Shim, Hyung Jin

    2012-01-01

    As The Monte Carlo (MC) particle transport analysis for a complex system such as research reactor, accelerator, and fusion facility may require accurate modeling of the complicated geometry. Its manual modeling by using the text interface of a MC code to define the geometrical objects is tedious, lengthy and error-prone. This problem can be overcome by taking advantage of modeling capability of the computer aided design (CAD) system. There have been two kinds of approaches to develop MC code systems utilizing the CAD data: the external format conversion and the CAD kernel imbedded MC simulation. The first approach includes several interfacing programs such as McCAD, MCAM, GEOMIT etc. which were developed to automatically convert the CAD data into the MCNP geometry input data. This approach makes the most of the existing MC codes without any modifications, but implies latent data inconsistency due to the difference of the geometry modeling system. In the second approach, a MC code utilizes the CAD data for the direct particle tracking or the conversion to an internal data structure of the constructive solid geometry (CSG) and/or boundary representation (B-rep) modeling with help of a CAD kernel. MCNP-BRL and OiNC have demonstrated their capabilities of the CAD-based MC simulations. Recently we have developed a CAD-based geometry processing module for the MC particle simulation by using the OpenCASCADE (OCC) library. In the developed module, CAD data can be used for the particle tracking through primitive CAD surfaces (hereafter the CAD-based tracking) or the internal conversion to the CSG data structure. In this paper, the performances of the text-based model, the CAD-based tracking, and the internal CSG conversion are compared by using an in-house MC code, McSIM, equipped with the developed CAD-based geometry processing module

  20. Mammographic surveillance in the follow up of early primary breast cancer in England: A cross-sectional survey

    International Nuclear Information System (INIS)

    Greenwood-Haigh, Lesley

    2009-01-01

    Purpose: The aim of this study was to determine current practice in the clinical setting at national and regional level of the use of mammographic surveillance in the follow up of patients surgically treated for early breast cancer. Method: A cross-sectional survey method was employed. Self-administered questionnaires were sent to a random selection of symptomatic breast imaging units representing all the cancer networks in England nationally, and all symptomatic breast imaging units in one cancer network regionally. Questions were designed to determine frequency and duration of mammographic surveillance for patients aged < 50 years and ≥50 years surgically treated by mastectomy or breast conserving surgery and the number of units with protocols based on the risk of local recurrence or development of a new primary breast cancer. Results: The protocols demonstrated a striking diversity in both the frequency and duration of mammographic surveillance; however the variation was less marked regionally. The duration of mammography for patient's aged ≥70 years surgically treated by mastectomy, demonstrated the greatest diversity (range: 0-15 years). Four protocols had regimes tailored to risk. Conclusion: The introduction of protocols based on risk of development of a local recurrence or new primary could prove cost effective by targeting mammographic surveillance to those who would benefit the most. The survey has demonstrated that a 'post-code lottery' exists for both the frequency and duration of mammographic surveillance in this patient group indicating an urgent need for evidence based national guidance.

  1. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  2. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  3. Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review

    International Nuclear Information System (INIS)

    Nothacker, Monika; Duda, Volker; Hahn, Markus; Warm, Mathias; Degenhardt, Friedrich; Madjar, Helmut; Weinbrenner, Susanne; Albert, Ute-Susann

    2009-01-01

    Mammographic screening alone will miss a certain fraction of malignancies, as evidenced by retrospective reviews of mammograms following a subsequent screening. Mammographic breast density is a marker for increased breast cancer risk and is associated with a higher risk of interval breast cancer, i.e. cancer detected between screening tests. The purpose of this review is to estimate risks and benefits of supplemental breast ultrasound in women with negative mammographic screening with dense breast tissue. A systematic search and review of studies involving mammography and breast ultrasound for screening of breast cancer was conducted. The search was performed for the period 1/2000-8/2008 within the data source of PubMed, DARE, and Cochrane databases. Inclusion and exclusion criteria were determined prospectively, and the Oxford evidence classification system for diagnostic studies was used for evidence level. The parameters biopsy rate, positive predictive value (PPV) for biopsy, cancer yield for breast ultrasound alone, and carcinoma detection rate by breast density were extracted or constructed. The systematic search identified no randomized controlled trials or systematic reviews, six cohort studies of intermediate level of evidence (3b) were found. Only two of the studies included adequate follow-up of subjects with negative or benign findings. Supplemental breast ultrasound after negative mammographic screening permitted diagnosis of primarily invasive carcinomas in 0.32% of women in breast density type categories 2-4 of the American College of Radiology (ACR); mean tumor size for those identified was 9.9 mm, 90% with negative lymph node status. Most detected cancers occurred in mammographically dense breast ACR types 3 and 4. Biopsy rates were in the range 2.3%-4.7%, with PPV of 8.4-13.7% for those biopsied due to positive ultrasound, or about one third of the PPV of biopsies due to mammography. Limitations: The study populations included wide age ranges, and

  4. Positive predictive value of abnormal mammographic findings and role of assessment procedures

    International Nuclear Information System (INIS)

    Menna, S.; Marra, V.; Di Virgilio, M.R.; Macchia, G.; Frigerio, A.

    1999-01-01

    To investigate the positive predictive value for cancer of abnormal mammographic findings and the role of assessment, the authors reviewed a series of 962 patients recalled and examined in the first breast screening center of Turin (Italy), out of 18996 women aged 50-59 from 1991 to 1995, within a population-based mammography program. The results of this study confirm the accuracy of mammography in the early detection of breast cancer and the different role of assessment procedures in the various abnormal mammographic findings. The improvement in positive predictive value for screening demonstrates the importance of the learning curve within the screening team. Most of this improvement could be referred to refined diagnostic criteria for calcifications [it

  5. Mucinous (colloid) breast cancer: mammographic and US features with histologic correlation

    International Nuclear Information System (INIS)

    Memis, Aysenur; Ozdemir, Necmettin; Parildar, Mustafa; Ustun, Esin Emin; Erhan, Yildiz

    2000-01-01

    Objective: Mucinous carcinoma of the breast presents with different survival rates in pure and mixed types. The purpose of this study was to correlate the mammographic and ultrasonographic findings of mucinous carcinoma with histologic features in different types and mucin rates. Material and methods: Thirty-four patients (2.3%) had mucinous cancer after retrospective review of the 1439 breast cancers diagnosed between 1990 and 1996. Twenty-seven patients, 19 pure and eight mixed type of mucinous carcinomas of the breast, were included in this study to evaluate the imaging findings. In 22 of these, the microscopic slides were available and re-evaluated to estimate the volume of extracellular mucin. The volume of the extracellular mucin was classified histologically as: (+), less than 50% of mucin; (++), 50-80% of mucin; and (+++), more than 80% of mucin. Mammographic features with emphasis on margin characteristics and sonographic echo pattern of tumors were correlated with histologic findings. Results: Ten cases (53%) of pure mucinous type carcinomas had a circumscribed mass lesion on the mammograms. The well-defined, lobulated margins of the masses were well correlated with pure histologic type (P 2 analysis) Two-thirds of these tumors had high volume extracellular mucin. All mixed type mucinous carcinomas demonstrated poorly defined or spiculated margins with no relation to the mucin rates (P<0.01). The sonographic appearances of the tumors showed correlation with histologic types. Most of the pure type carcinomas (53%) were seen with isoechogenic echo texture relative to that of subcutaneous fat, while all of the mixed type carcinomas were hypoechogenic (P<0.01). Conclusion: The mammographic and sonographic features of mucinous breast carcinoma show differences in pure and mixed types of the tumor. The most common mammographic appearance of pure mucinous carcinomas with high percentages of mucin is a mass lesion having well-defined margins, which is

  6. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  7. Results of conservative surgery and radiation for mammographically detected ductal carcinoma in situ (DCIS)

    International Nuclear Information System (INIS)

    Fowble, B.; Hanlon, A.L.; Fein, D.A.; Hoffman, J.P.; Sigurdson, E.R.; Patchefsky, A.; Kessler, H.

    1996-01-01

    Purpose: The role of conservative surgery and radiation for mammographically detected DCIS is controversial. In particular, there is a paucity of data for outcome with radiation in a group of patients comparable to those treated with local excision and surveillance (mammographically detected DCIS ≤2.5 cm, negative resection margins, negative post-biopsy mammogram). The purpose of this study is to report long term outcome of conservative surgery and radiation for mammographically detected DCIS with emphasis on the results in patients (pts.) considered candidates for excision alone. Materials and Methods: From 1983 to 1992, 110 women with mammographically detected DCIS (calcifications 72%, mass ± calcifications 27%) and no prior history of breast cancer underwent needle localization biopsy followed by radiation. The median age of the patient population was 56 yrs. (range 37-81). The median followup was 5.3 yrs. (range .5-12). Re-excision was performed in 55%. Final margins of resection were negative in 62%, positive 7%, close 11%, and unknown 20%. Axillary dissection was performed in 31 pts. and all had negative nodes. 31% had a positive family history of breast cancer (1 affected relative-25 pts., two-7 pts., three-2 pts.). The most common predominant histologic subtype was comedo (54%) followed by cribriform (22%). The median pathologic tumor size was 8 mm (range 2 mm to 5 cm). A post-biopsy mammogram prior to radiation was performed in 46% of the patients. Radiation consisted of treatment to the entire breast (median 5000 cGy) with a boost to the primary site (97%) of an additional 1000 cGy. The median total dose to the primary site was 6040 cGy (range 5000 to 6660). Results: Three patients developed a recurrence in the treated breast at 52, 106, and 107 months. All 3 recurrences were invasive ductal cancers and all were treated with mastectomy. The location of the recurrence was in the same quadrant as the primary in 1 pt. and in a separate quadrant in 2 pts

  8. Diagnostic imaging of lobular carcinoma of the breast. Mammographic, US and MR findings

    International Nuclear Information System (INIS)

    Bazzocchi, M.; Facecchia, I.; Zuiani, C.; Smania, S.; Puglisi, F.; Di Loreto, C.

    2000-01-01

    Purpose of this article is to evaluate the most frequent mammographic, US and MR findings of invasive lobular carcinoma and the role of MRI in defining multifocality and/or multi centricity of this tumor histotype. 45 lobular carcinomas in 39 patients were studied and selected from 421 breast cancers. Core biopsy with a 14G needle was performed in 39 cases, under US guidance in 36/39 and under mammographic guidance in 3/39 cases. Surgical biopsy was performed in 2 cases and the diagnosis could be made only after mastectomy in 5 cases. All patients were examined with mammography and US and (10-13 MHz) and 8 also with MRI. 28/46 palpable lesions (60.9%). Core biopsy correctly diagnosed 38/39 lesions (97.4%). The most frequent mammographic findings was that of a nodular opacity without microcalcifications (34.8%), followed by a mass with spiculate d borders (30.4%). Microcalcifications were seen in one case only (2.2%). Mammography detected no abnormalities in 15.2% of cases, but US showed a lesion in 2 of these cases. The most frequent US pattern was that of a hypoechoic lesion (43.5%), followed by posterior US beam attenuation. No US signs of abnormality were seen 15.2%. MRI correctly detected 13 lesions. Contrast enhancement was greater than 70% at one minute in 10 cases and greater than 40% in one case; two lesions exhibited atypical slow contrast enhancement, peaking at 5 minutes. MRI detected 5 lesions missed both mammography and US and showed multifocal (3 and 2) lesions where the other techniques had detected one lesion only. At mammography and US invasive lobular carcinoma exhibits no different features than ductal carcinoma but is difficult to identify especially in its early stages. US is a useful tool especially to characterize mammography-detected lesions but in the experience it also demonstrated 2 lesions missed at mammography. MRI is a precious examination to define the multifocal, multi centric or bilateral character of invasive lobular carcinoma

  9. Peningkatan Prestasi Belajar CAD Mahasiswa Teknik Otomotif Non-Reguler FT UNY melalui Pembuatan “Pohon Kata” Perintah dalam Program AutoCAD

    Directory of Open Access Journals (Sweden)

    Martubi Martubi

    2010-05-01

    Full Text Available Penelitian ini bertujuan meningkatkan prestasi belajar mata kuliah Computer Aided Design (CAD mahasiswa prodi Teknik Otomotif Non-Reguler yang dinyatakan dalam bentuk rerata nilai akhir semester yang berasal dari komponen nilai tugas harian, nilai ujian tengah semester dan nilai ujian akhir semester. Penelitian quasi-eksperimen ini terdiri dari tahapan penelitian diawali dengan penyusunan materi pembelajaran sejumlah pokok bahasan tertentu dalam satu job sheet (lembar kerja, dilanjutkan dengan pembuatan bantuan “Pohon Kata” perintah dalam Auto CAD kepada kelas eksperimen yang ditentukan secara random dari dua kelas peserta kuliah Auto CAD pada Semester Genap 2008/2009. Kedua kelas diamati prestasinya, baik kecepatan penyelesaiannya maupun kualitas kebenaran gambarnya. Prestasi belajar kedua kelas juga diukur melalui pemberian ujian tengah semester dan ujian akhir semester. Setelah data prestasi kedua kelas terkumpul dilanjutkan dengan analisis statistik melalui uji beda (t-test setelah sebelumnya dilakukan uji persyaratan analisis yang ternyata dapat dipenuhi. Hasil penelitian ini disimpulkan bahwa: prestasi belajar CAD mahasiswa pada kelas yang diberi perlakuan strategi pembelajaran menggunakan “Pohon Kata” perintah dalam Program Auto CAD lebih baik dibanding prestasi belajar CAD mahasiswa pada kelas yang tidak diberi perlakuan (75,41>70,89, dengan demikian pembelajaran CAD menggunakan media “Pohon Kata” perintah dalam Program Auto CAD dapat meningkatkan prestasi belajar mahasiswa Teknik Otomotif Program Non-Reguler.

  10. Combining photogrammetry and CAD

    International Nuclear Information System (INIS)

    Borowsky, V.

    1993-01-01

    In nuclear power plants photogrammetry is being used to supply the data needed for setting up 3D CAD models. At Siemens, project handling has been made more economical by using photogrammetry and 3D CAD as a single process. Photogrammetry can be used for modelling extensive sections of the plant or small areas. Areas which particularly lend themselves to the use of photogrammetry are those with a high level of radiation or those yielding a large volume of data. (author)

  11. Application of Auto CAD

    International Nuclear Information System (INIS)

    Park, Yong Un; Kim, Geun Ho

    1989-05-01

    This book has introduction to use this book and explanation of application on Auto CAD, which includes, sub directories, batch files, robot wrist, design of standard paper, title block, robort weld room, robert wrist joint, PC board, plant sym, electro, PID, machines, robots, bubbles, plant, schema, Pid, plant assembly, robots, dim plant, PL-ASSM, plotting line weight control, symbol drawing joint, Auto CAD using script file, set up of workout · MNU, workout MNU, ACAD, LSP and workout · MNU.

  12. Successfully converting mine maps to CAD

    Energy Technology Data Exchange (ETDEWEB)

    Munn, M.D. (Image Conversion Services, Inc., Salt Lake City, UT (USA))

    1991-03-01

    Procedures followed by computer service bureaus to convert paper drawing to digital files that can be used by CAD systems are described. The conversion involves laser scanning of original drawings to produce an 'inactive image' (a form suitable for many drawings that do not need to be changed). Using optical character recognition software the image is then vectorized or converted from raster format to geometric elements usable in a CAD system. The vectorized image can then be cleaned up corrected and changed at the CAD workstation. 4 figs.

  13. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  14. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  15. PV-CAD: an integrated tool for designing PV facades; PV-CAD - Ein integriertes Werkzeug zur Auslegung von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Giese, H.; Viotto, M. [Inst. fuer Solare Energieversorgungstechnik (ISET) e.V., Kassel (Germany); Esser, M.; Pukrop, D. [Univ. Oldenburg (Germany). Abt. Energie- und Halbleiterforschung; Stellbogen, D. [Zentrum fuer Sonnenergie- und Wasserstoff-Forschung, Stuttgart (Germany)

    1997-12-31

    PV-CAD provides PV system planners with a practice-oriented tool for an efficient design of PV facades. Being compatible with the standard programmes of the architects` and electrical engineering sectors it can be used on already existing systems and allows the user to draw on previously acquired knowedge. Its open interfaces permit the integration of further design tools. PV CAD works under Microsoft Windows for which it has the necessary graphic user interface. Its compliance to PC standards opens up a wide range of applications and permits its use also on inexpensive computers. Thanks to its promotion by the Federal Ministry for Education, Science, Research, and Technology under the research project ``Computer programmes for the design of photovoltaic facades`` PV-CAD is available at a moderate price. PV-CAD permits an efficient planning of solar facades and therefore has the potential to stimulate the use of PV on buildings. (orig.) [Deutsch] Mit PV-CAD steht dem Anlagenplaner ein anwendungsorientiertes Werkzeug zur Verfuegung, das eine rationelle Auslegung von PV-Fassaden ermoeglicht. Die Kompatibilitaet zu Standardprogrammen aus dem Architektur- und Elektrosektor erlaubt die Nutzung bereits vorhandener Systeme und damit erworbener Kenntnisse. Offene Schnittstellen gestatten die Einbindung weiterer Entwurfswerkzeuge. PV-CAD arbeitet unter Microsoft-Windows und verfuegt ueber die entsprechende grafische Benutzerschnittstelle. Die Kompatibilitaet zum PC-Standard eroeffnet eine sehr breite Anwenderbasis und ermoeglicht den Einsatz des Programms auch auf preiswerten Rechnern. Aufgrund der Foerderung durch das Bundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie im Rahmen des Forschungsprojekts `Rechnerprogramm zur Auslegung von Photovoltaik-Fassaden` steht PV-CAD preiswert zur Verfuegung. PV-CAD ermoeglicht eine effiziente Planung von Solarfassaden und kann daher dem PV-Einsatz in Gebaeuden weitere Impulse geben. (orig.)

  16. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses.

    Science.gov (United States)

    Yilmaz, Burak; Alp, Gülce; Seidt, Jeremy; Johnston, William M; Vitter, Roger; McGlumphy, Edwin A

    2018-01-06

    The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). Statistically significant differences were found among load-to-fracture values of different HDPs (PCAD-CAM polymer. GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers

  17. Possible effects of insulin-like growth factor-I, IGF-binding protein-3 and IGF-1/IGFBP-3 molar ratio on mammographic density: a cross-sectional study.

    Science.gov (United States)

    Meggiorini, M L; Cipolla, V; Borgoni, G; Nofroni, I; Pala, A; de Felice, C

    2012-01-01

    The purpose of this study was to examine the possible effects of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio on mammographic density and assess whether this relationship was similar in subgroups of pre- and postmenopausal women. A group of 341 Italian women of childbearing age or naturally postmenopausal who had performed mammographic examination at the section of radiology of our department a maximum three months prior to recruitment were enrolled. A blood sample was drawn for determination of IGF-1, IGFBP-3 levels and IGF-1/IGFBP-3 molar ratio was calculated. On the basis of recent mammograms the women were divided into two groups: dense breast (DB) and non-dense breast (NDB). To assess the association between mammographic density and IGF-1, IGFBP-3 and Molar ratio Student's t-test was employed before and after stratified by menopausal status. The analysis of the relationship between mammographic density and plasma levels of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio showed that IGF-1 levels and molar ratio varied in the two groups resulting in higher mean values in the DB group whereas IGFBP-3 showed similar values in both groups (DB and NDB). After stratification of the study population by menopausal status, no association was found. Our study provides strong evidence of a crude association between breast density, and plasma levels of IGF-1 and molar ratio. IGF-1 and molar ratio might increase mammographic density and thus the risk of developing breast cancer.

  18. Theory and practice of Auto CAD, computer graphics

    International Nuclear Information System (INIS)

    Hwang, Si Won; Choe, Hong Yeong; Shin, Jae Yeon; Lee, Ryong Cheol

    1990-08-01

    This book describes theory and practice of Auto CAD, computer graphics, which deals with peripheral of computer, occurrence of digital line by DDA, BRM, theory of conversion, data base and display and shape modeling. This book gives descriptions of outline of CAD system, Auto CAD, basic function practice, simple figure practice, the third angle projection drawing a little complex single object, machine drawing I, function practice of improved Auto CAD, edit, set up layer, and 3D, and 3D display function.

  19. Or CAD 9.1

    International Nuclear Information System (INIS)

    Lee, Seung Mu

    2000-02-01

    This book gives descriptions of Or CAD 9.1 with before drawing plan such as gaining Or CAD Demo CD, capture tools, making new design file, drawing structure, and setting design template, Drawings like making new drawing, finding parts, drawing lines, connecting line among the pages, and connecting parts using drawing structure, unstable multivibrator circle such as management of design file, power and ground connection, utility, beginning layout, single drawing, flat drawing, latch circuit, making a library, making a footprint, smart route and flash window.

  20. Quantitative assessment of multiple sclerosis lesion load using CAD and expert input

    Science.gov (United States)

    Gertych, Arkadiusz; Wong, Alexis; Sangnil, Alan; Liu, Brent J.

    2008-03-01

    Multiple sclerosis (MS) is a frequently encountered neurological disease with a progressive but variable course affecting the central nervous system. Outline-based lesion quantification in the assessment of lesion load (LL) performed on magnetic resonance (MR) images is clinically useful and provides information about the development and change reflecting overall disease burden. Methods of LL assessment that rely on human input are tedious, have higher intra- and inter-observer variability and are more time-consuming than computerized automatic (CAD) techniques. At present it seems that methods based on human lesion identification preceded by non-interactive outlining by CAD are the best LL quantification strategies. We have developed a CAD that automatically quantifies MS lesions, displays 3-D lesion map and appends radiological findings to original images according to current DICOM standard. CAD is also capable to display and track changes and make comparison between patient's separate MRI studies to determine disease progression. The findings are exported to a separate imaging tool for review and final approval by expert. Capturing and standardized archiving of manual contours is also implemented. Similarity coefficients calculated from quantities of LL in collected exams show a good correlation of CAD-derived results vs. those incorporated as expert's reading. Combining the CAD approach with an expert interaction may impact to the diagnostic work-up of MS patients because of improved reproducibility in LL assessment and reduced time for single MR or comparative exams reading. Inclusion of CAD-generated outlines as DICOM-compliant overlays into the image data can serve as a better reference in MS progression tracking.

  1. Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

    Science.gov (United States)

    Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna

    2015-11-01

    The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate

  2. Red clover-derived isoflavones and mammographic breast density: a double-blind, randomized, placebo-controlled trial [ISRCTN42940165

    International Nuclear Information System (INIS)

    Atkinson, Charlotte; Warren, Ruth ML; Sala, Evis; Dowsett, Mitch; Dunning, Alison M; Healey, Catherine S; Runswick, Shirley; Day, Nicholas E; Bingham, Sheila A

    2004-01-01

    Isoflavones are hypothesized to protect against breast cancer, but it is not clear whether they act as oestrogens or anti-oestrogens in breast tissue. Our aim was to determine the effects of taking a red clover-derived isoflavone supplement daily for 1 year on mammographic breast density. Effects on oestradiol, follicle-stimulating hormone (FSH), luteinizing hormone (LH), lymphocyte tyrosine kinase activity and menopausal symptoms were also assessed. A total of 205 women (age range 49–65 years) with Wolfe P2 or DY mammographic breast patterns were randomly assigned to receive either a red clover-derived isoflavone tablet (26 mg biochanin A, 16 mg formononetin, 1 mg genistein and 0.5 mg daidzein) or placebo. Change in mammographic breast density, serum oestradiol, FSH, LH, menopausal symptoms and lymphocyte tyrosine kinase activity from baseline to 12 months were assessed. A total of 177 women completed the trial. Mammographic breast density decreased in both groups but the difference between the treatment and placebo was not statistically significant. There was a significant interaction between treatment group and oestrogen receptor (ESR1) PvuII polymorphism for the change in estimated percentage breast density (mean ± standard deviation): TT isoflavone 1.4 ± 12.3% and TT placebo -9.6 ± 14.2%; CT isoflavone -5.2 ± 12.0% and CT placebo -2.8 ± 10.3%; and CC isoflavone -3.4 ± 9.7% and CC placebo -1.1 ± 9.5%. There were no statistically significant treatment effects on oestradiol, FSH, or LH (assessed only in postmenopausal women), or on lymphocyte tyrosine kinase activity. Baseline levels of menopausal symptoms were low, and there were no statistically significant treatment effects on frequency of hot flushes or other menopausal symptoms. In contrast to studies showing that conventional hormone replacement therapies increase mammographic breast density, the isoflavone supplement did not increase mammographic breast density in this population of women

  3. Identification of a novel percent mammographic density locus at 12q24.

    Science.gov (United States)

    Stevens, Kristen N; Lindstrom, Sara; Scott, Christopher G; Thompson, Deborah; Sellers, Thomas A; Wang, Xianshu; Wang, Alice; Atkinson, Elizabeth; Rider, David N; Eckel-Passow, Jeanette E; Varghese, Jajini S; Audley, Tina; Brown, Judith; Leyland, Jean; Luben, Robert N; Warren, Ruth M L; Loos, Ruth J F; Wareham, Nicholas J; Li, Jingmei; Hall, Per; Liu, Jianjun; Eriksson, Louise; Czene, Kamila; Olson, Janet E; Pankratz, V Shane; Fredericksen, Zachary; Diasio, Robert B; Lee, Adam M; Heit, John A; DeAndrade, Mariza; Goode, Ellen L; Vierkant, Robert A; Cunningham, Julie M; Armasu, Sebastian M; Weinshilboum, Richard; Fridley, Brooke L; Batzler, Anthony; Ingle, James N; Boyd, Norman F; Paterson, Andrew D; Rommens, Johanna; Martin, Lisa J; Hopper, John L; Southey, Melissa C; Stone, Jennifer; Apicella, Carmel; Kraft, Peter; Hankinson, Susan E; Hazra, Aditi; Hunter, David J; Easton, Douglas F; Couch, Fergus J; Tamimi, Rulla M; Vachon, Celine M

    2012-07-15

    Percent mammographic density adjusted for age and body mass index (BMI) is one of the strongest risk factors for breast cancer and has a heritable component that remains largely unidentified. We performed a three-stage genome-wide association study (GWAS) of percent mammographic density to identify novel genetic loci associated with this trait. In stage 1, we combined three GWASs of percent density comprised of 1241 women from studies at the Mayo Clinic and identified the top 48 loci (99 single nucleotide polymorphisms). We attempted replication of these loci in 7018 women from seven additional studies (stage 2). The meta-analysis of stage 1 and 2 data identified a novel locus, rs1265507 on 12q24, associated with percent density, adjusting for age and BMI (P = 4.43 × 10(-8)). We refined the 12q24 locus with 459 additional variants (stage 3) in a combined analysis of all three stages (n = 10 377) and confirmed that rs1265507 has the strongest association in the 12q24 region (P = 1.03 × 10(-8)). Rs1265507 is located between the genes TBX5 and TBX3, which are members of the phylogenetically conserved T-box gene family and encode transcription factors involved in developmental regulation. Understanding the mechanism underlying this association will provide insight into the genetics of breast tissue composition.

  4. Dataudveksling mellem CAD og CAE programmer

    DEFF Research Database (Denmark)

    Sørensen, Torben; Conrad, Finn

    2001-01-01

    Når mange forskelligartede programmer benyttes til beregninger og anden databehandling på samme modeller er det nødvendig at udveksle modellerne mellem disse forskellige programmer. Biler og skibe bliver f.eks. typisk designet i 3D CAD systemer, mens CAD modellerne herefter anvendes i andre...... dedikerede IT-systemer i forbindelse montageplanlægningen, svejseplanlægningen, robotprogrammeringen mm. der således her et behov for at udveksle CAD modellen mellem de forskellige programmer. Udveksling af information mellem forskellige programmer og systemer kræver såvel en fælles specifikation af det...

  5. Computer-aided detection (CAD) of lung nodules and small tumours on chest radiographs

    International Nuclear Information System (INIS)

    De Boo, D.W.; Prokop, M.; Uffmann, M.; Ginneken, B. van; Schaefer-Prokop, C.M.

    2009-01-01

    Detection of focal pulmonary lesions is limited by quantum and anatomic noise and highly influenced by variable perception capacity of the reader. Multiple studies have proven that lesions - missed at time of primary interpretation - were visible on the chest radiographs in retrospect. Computer-aided diagnosis (CAD) schemes do not alter the anatomic noise but aim at decreasing the intrinsic limitations and variations of human perception by alerting the reader to suspicious areas in a chest radiograph when used as a 'second reader'. Multiple studies have shown that the detection performance can be improved using CAD especially for less experienced readers at a variable amount of decreased specificity. There seem to be a substantial learning process for both, experienced and inexperienced readers, to be able to optimally differentiate between false positive and true positive lesions and to build up sufficient trust in the capabilities of these systems to be able to use them at their full advantage. Studies so far focussed on stand-alone performance of the CAD schemes to reveal the magnitude of potential impact or on retrospective evaluation of CAD as a second reader for selected study groups. Further research is needed to assess the performance of these systems in clinical routine and to determine the trade-off between performance increase in terms of increased sensitivity and decreased inter-reader variability and loss of specificity and secondary indicated follow-up examinations for further diagnostic workup.

  6. Tumor location and detectability in mammographic screening

    International Nuclear Information System (INIS)

    Schmitt, E.L.; Threatt, B.

    1982-01-01

    The adequacy of a film mammogram that does not visualize the retromammary space or ribs has concerned radiologists. The 79 prevalent cancers detected in the 10,000 self-referred woman at the University of Michigan Breast Cancer Detection Demonstration Project were analyzed for number of films required to detect the cancer, relationship of the cancer to the posterior edge of the film, number of occult lesions, tumor size, histologic type, sensitivity of detection method, and number of interval carcinomas. The mammograms were obtained using a dedicated mammographic machine and the upright position, with visualization of the anterior axillary fold on the mediolateral view. The ribs were not imaged. Of the 79 cancers, 76 were detectable on the mammogram. All were visualized on the mediolateral view, while three were not imaged on the craniocaudal view. Twelve percent of the cancers were within 1 cm of the posterior edge of the film. Only six ''interval'' carcinomas were found in the 10,000 patients within the year of the initial examinations; these women had dense P2 or DY mammographic parenchymal patterns. The detected cancers were smaller and had a significantly higher percentage of noninvasive cancers than in a symptomatic clinical population. Thus, properly exposed film mammograms using vigorous breast compression examine the breast adequately without visualizing the ribs

  7. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. A comparison of computer-assisted detection (CAD) programs for the identification of colorectal polyps: performance and sensitivity analysis, current limitations and practical tips for radiologists.

    Science.gov (United States)

    Bell, L T O; Gandhi, S

    2018-06-01

    To directly compare the accuracy and speed of analysis of two commercially available computer-assisted detection (CAD) programs in detecting colorectal polyps. In this retrospective single-centre study, patients who had colorectal polyps identified on computed tomography colonography (CTC) and subsequent lower gastrointestinal endoscopy, were analysed using two commercially available CAD programs (CAD1 and CAD2). Results were compared against endoscopy to ascertain sensitivity and positive predictive value (PPV) for colorectal polyps. Time taken for CAD analysis was also calculated. CAD1 demonstrated a sensitivity of 89.8%, PPV of 17.6% and mean analysis time of 125.8 seconds. CAD2 demonstrated a sensitivity of 75.5%, PPV of 44.0% and mean analysis time of 84.6 seconds. The sensitivity and PPV for colorectal polyps and CAD analysis times can vary widely between current commercially available CAD programs. There is still room for improvement. Generally, there is a trade-off between sensitivity and PPV, and so further developments should aim to optimise both. Information on these factors should be made routinely available, so that an informed choice on their use can be made. This information could also potentially influence the radiologist's use of CAD results. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. AutoCAD 2014 review for certification official certification preparation

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The AutoCAD® 2014 Review for Certification book is intended for users of AutoCAD® preparing to complete the AutoCAD 2014 Certified Professional exam. This book contains a collection of relevant instructional topics, practice exercises, and review questions from the Autodesk Official Training Guides (AOTG) from ASCENT - Center for Technical Knowledge pertaining specifically to the Certified Professional exam topics and objectives. This book is intended for experienced users of AutoCAD in preparation for certification. New users of AutoCAD should refer to the AOTG training guides from ASCENT, such as AutoCAD/AutoCAD LT 2014 Fundamentals, for more comprehensive instruction.

  10. The effect of milling and postmilling procedures on the surface roughness of CAD/CAM materials.

    Science.gov (United States)

    Mota, Eduardo Gonçalves; Smidt, Laura Nunes; Fracasso, Lisiane Martins; Burnett, Luiz Henrique; Spohr, Ana Maria

    2017-11-12

    The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures. Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL. Ten flat samples of each material were obtained. The surface roughness (Ra) test was performed before and after milling, crystallization, polishing, and glaze when indicated, followed by SEM and AFM analysis. Data were submitted to one-way ANOVA with repeated measures and the Tukey HSD test (α = 0.05). The milling step significantly increased the roughness of all the tested materials (P CAD and Suprinity) were more suitable to roughness than the other tested materials (P CAD/CAM materials, that is, fully sintered, should be only hand polished. The glaze step can be suppressed resulting in time saving. However, the glaze step in soft-milling lithium disilicate is imperative. © 2017 Wiley Periodicals, Inc.

  11. Importing CAD models into MONK and MCBEND

    International Nuclear Information System (INIS)

    Searson, K.; Fleurot, F.; Cooper, A. J.; Cowan, P.

    2009-01-01

    The direct use of Computer Aided Design (CAD) models in criticality and shielding codes has been a long standing goal for Sellafield Ltd. Such functionality could offer several advantages over the traditional method of text based modelling systems. Analysts would be able to take advantage of the advanced Graphical User Interface based modelling features provided by solid modelers, potentially reducing the costs associated with creating models in a format suitable for the analyst's criticality and shielding code. A prototype system has been developed that allows CAD models created in Autodesk Inventor or Solidworks to be used in criticality and shielding calculations. The system is based on the ANSI Initial Graphics Exchange Specification 5.3 standard and models are exported from the CAD software in Trimmed NURBS format. The format retains much more of the model's geometrical information than a format based on solid meshing techniques and avoids many of the associated problems such as large memory costs, surface approximations and void spaces. The time consuming and complex meshing process is also avoided. Runtime intersection calculations are performed using either a Bezier clipping process for NURBS based surface definitions, or by transforming the coordinate system through which the ray tracks for Surface of Revolution calculations. NURBS surfaces are therefore converted to Bezier form as the model is imported. In addition, the SR generatrix is, in general, converted to a 'strip tree' representation, allowing the SR intersection calculations to be performed with arbitrary generatrix shapes. Details of recent improvements to the Bezier clipping process are provided. Reduction in runtime of SR based Solidworks models over equivalent NURBS based Autodesk Inventor models is also demonstrated. (authors)

  12. Role of radiologists in CAD life-cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pietka, Ewa, E-mail: ewa.pietka@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Kawa, Jacek, E-mail: jacek.kawa@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Spinczyk, Dominik, E-mail: dominik.spinczyk@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Badura, Pawel, E-mail: pawel.badura@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Wieclawek, Wojciech, E-mail: wojciech.wieclawek@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Czajkowska, Joanna, E-mail: joanna.czajkowska@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Rudzki, Marcin, E-mail: marcin.rudzki@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland)

    2011-05-15

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  13. Role of radiologists in CAD life-cycle

    International Nuclear Information System (INIS)

    Pietka, Ewa; Kawa, Jacek; Spinczyk, Dominik; Badura, Pawel; Wieclawek, Wojciech; Czajkowska, Joanna; Rudzki, Marcin

    2011-01-01

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  14. Mammographic density changes following discontinuation of tamoxifen in premenopausal women with oestrogen receptor-positive breast cancer.

    Science.gov (United States)

    Kim, Won Hwa; Cho, Nariya; Kim, Young-Seon; Yi, Ann

    2018-04-06

    To evaluate the changes in mammographic density after tamoxifen discontinuation in premenopausal women with oestrogen receptor-positive breast cancers and the underlying factors METHODS: A total of 213 consecutive premenopausal women with breast cancer who received tamoxifen treatment after curative surgery and underwent three mammograms (baseline, after tamoxifen treatment, after tamoxifen discontinuation) were included. Changes in mammographic density after tamoxifen discontinuation were assessed qualitatively (decrease, no change, or increase) by two readers and measured quantitatively by semi-automated software. The association between % density change and clinicopathological factors was evaluated using univariate and multivariate regression analyses. After tamoxifen discontinuation, a mammographic density increase was observed in 31.9% (68/213, reader 1) to 22.1% (47/213, reader 2) by qualitative assessment, with a mean density increase of 1.8% by quantitative assessment compared to density before tamoxifen discontinuation. In multivariate analysis, younger age (≤ 39 years) and greater % density decline after tamoxifen treatment (≥ 17.0%) were independent factors associated with density change after tamoxifen discontinuation (p density change with a mean density increase of 1.8%, which was associated with younger age and greater density change after tamoxifen treatment. • Increased mammographic density after tamoxifen discontinuation can occur in premenopausal women. • Mean density increase after tamoxifen discontinuation was 1.8%. • Density increase is associated with age and density decrease after tamoxifen.

  15. ORIGINAL ARTICLE ORIG ORIG Mammographic CAD: Correlation ...

    African Journals Online (AJOL)

    remove any directional effects that may be introduced by the change in orientation of .... The selection of the best combination of AUC and C values is facilitated by .... Examples of similarity maps for TM-matching and MI-matching are shown in ...

  16. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  17. Integration of computer-aided diagnosis/detection (CAD) results in a PACS environment using CAD-PACS toolkit and DICOM SR

    International Nuclear Information System (INIS)

    Le, Anh H.T.; Liu, Brent; Huang, H.K.

    2009-01-01

    Picture Archiving and Communication System (PACS) is a mature technology in health care delivery for daily clinical imaging service and data management. Computer-aided detection and diagnosis (CAD) utilizes computer methods to obtain quantitative measurements from medical images and clinical information to assist clinicians to assess a patient's clinical state more objectively. CAD needs image input and related information from PACS to improve its accuracy; and PACS benefits from CAD results online and available at the PACS workstation as a second reader to assist physicians in the decision making process. Currently, these two technologies remain as two separate independent systems with only minimal system integration. This paper describes a universal method to integrate CAD results with PACS in its daily clinical environment. The method is based on Health Level 7 (HL7) and Digital imaging and communications in medicine (DICOM) standards, and Integrating the Healthcare Enterprise (IHE) workflow profiles. In addition, the integration method is Health Insurance Portability and Accountability Act (HIPAA) compliant. The paper presents (1) the clinical value and advantages of integrating CAD results in a PACS environment, (2) DICOM Structured Reporting formats and some important IHE workflow profiles utilized in the system integration, (3) the methodology using the CAD-PACS integration toolkit, and (4) clinical examples with step-by-step workflows of this integration. (orig.)

  18. Controlled exstirpation of clinically occult but mammographically suspicious findings

    Energy Technology Data Exchange (ETDEWEB)

    Grosse-Vorholt, R

    1981-03-01

    Breast-volume, size and mammographical findings near the chest wall have a great influence on the excision for histological examination. The excision should be done as an controled excision by preoperative marking with a mixture of blue colour and contrast-medium followed by an intraoperative radiography of the exstirpated tissue. We reached in 30 cases a sure excision without any postoperative complications.

  19. Productivity increase through implementation of CAD/CAE workstation

    Science.gov (United States)

    Bromley, L. K.

    1985-01-01

    The tracking and communication division computer aided design/computer aided engineering system is now operational. The system is utilized in an effort to automate certain tasks that were previously performed manually. These tasks include detailed test configuration diagrams of systems under certification test in the ESTL, floorplan layouts of future planned laboratory reconfigurations, and other graphical documentation of division activities. The significant time savings achieved with this CAD/CAE system are examined: (1) input of drawings and diagrams; (2) editing of initial drawings; (3) accessibility of the data; and (4) added versatility. It is shown that the Applicon CAD/CAE system, with its ease of input and editing, the accessibility of data, and its added versatility, has made more efficient many of the necessary but often time-consuming tasks associated with engineering design and testing.

  20. Prognosis for Mammographically Occult, Early-Stage Breast Cancer Patients Treated With Breast-Conservation Therapy

    International Nuclear Information System (INIS)

    Yang, Tzu-I. J.; Yang Qifeng; Haffty, Bruce G.; Moran, Meena S.

    2010-01-01

    Purpose: To compare mammographically occult (MamOcc) and mammographically positive (MamPos) early-stage breast cancer patients treated with breast-conservation therapy (BCT), to analyze differences between the two cohorts. Methods and Materials: Our two cohorts consisted of 214 MamOcc and 2168 MamPos patients treated with BCT. Chart reviews were conducted to assess mammogram reports and method of detection. All clinical-pathologic and outcome parameters were analyzed to detect differences between the two cohorts. Results: Median follow-up was 7 years. There were no differences in final margins, T stage, nodal status, estrogen/progesterone receptor status, or 'triple-negative' status. Significant differences included younger age at diagnosis (p o histology (p < 0.0001). At 10 years, the differences in overall survival, cause-specific survival, and distant relapse between the two groups did not differ significantly. The MamOcc cohort had more breast relapses (15% vs. 8%; p = 0.0357), but on multivariate analysis this difference was not significant (hazard ratio 1.0, 95% confidence interval 0.993-1.007, p = 0.9296). Breast relapses were mammographically occult in 32% of the MamOcc and 12% of the MamPos cohorts (p = 0.0136). Conclusions: Although our study suggests that there are clinical-pathologic variations for the MamOcc cohort vs. MamPos patients that may ultimately affect management, breast relapse after BCT was not significantly different. Breast recurrences were more often mammographically occult in the MamOcc cohort; consideration should be given to closer follow-up and alternative imaging strategies (ultrasound, breast MRI) for routine posttreatment examination. To our knowledge, this represents the largest series addressing the prognostic significance of MamOcc cancers treated with BCT.

  1. Annotation and retrieval system of CAD models based on functional semantics

    Science.gov (United States)

    Wang, Zhansong; Tian, Ling; Duan, Wenrui

    2014-11-01

    CAD model retrieval based on functional semantics is more significant than content-based 3D model retrieval during the mechanical conceptual design phase. However, relevant research is still not fully discussed. Therefore, a functional semantic-based CAD model annotation and retrieval method is proposed to support mechanical conceptual design and design reuse, inspire designer creativity through existing CAD models, shorten design cycle, and reduce costs. Firstly, the CAD model functional semantic ontology is constructed to formally represent the functional semantics of CAD models and describe the mechanical conceptual design space comprehensively and consistently. Secondly, an approach to represent CAD models as attributed adjacency graphs(AAG) is proposed. In this method, the geometry and topology data are extracted from STEP models. On the basis of AAG, the functional semantics of CAD models are annotated semi-automatically by matching CAD models that contain the partial features of which functional semantics have been annotated manually, thereby constructing CAD Model Repository that supports model retrieval based on functional semantics. Thirdly, a CAD model retrieval algorithm that supports multi-function extended retrieval is proposed to explore more potential creative design knowledge in the semantic level. Finally, a prototype system, called Functional Semantic-based CAD Model Annotation and Retrieval System(FSMARS), is implemented. A case demonstrates that FSMARS can successfully botain multiple potential CAD models that conform to the desired function. The proposed research addresses actual needs and presents a new way to acquire CAD models in the mechanical conceptual design phase.

  2. Evaluation of the optimum region for mammographic system using computer simulation to study modulation transfer functions

    International Nuclear Information System (INIS)

    Oliveira, Isaura N. Sombra; Schiable, Homero; Porcel, Naider T.; Frere, Annie F.; Marques, Paulo M.A.

    1996-01-01

    An investigation of the 'optimum region' of the radiation field considering mammographic systems is studied. Such a region was defined in previous works as the field range where the system has its best performance and sharpest images. This study is based on a correlation of two methods for evaluating radiologic imaging systems, both using computer simulation in order to determine modulation transfer functions (MTFs) due to the X-ray tube focal spot in several field orientation and locations

  3. Smoking and high-risk mammographic parenchymal patterns: a case-control study

    International Nuclear Information System (INIS)

    Sala, Evis; Warren, Ruth; McCann, Jenny; Duffy, Stephen; Luben, Robert; Day, Nicholas

    2000-01-01

    Current smoking was strongly and inversely associated with high-risk patterns, after adjustment for concomitant risk factors. Relative to never smokers, current smokers were significantly less likely to have a high-risk pattern. Similar results were obtained when the analysis was confined to postmenopausal women. Past smoking was not related to the mammographic parenchymal patterns. The overall effect in postmenopausal women lost its significance when adjusted for other risk factors for P2/DY patterns that were found to be significant in the present study, although the results are still strongly suggestive. The present data indicate that adjustment for current smoking status is important when evaluating the relationship between mammographic parenchymal pattern and breast cancer risk. They also indicate that smoking is a prominent potential confounder when analyzing effects of other risk factors such as obesity-related variables. It appears that parenchymal patterns may act as an informative biomarker of the effect of cigarette smoking on breast cancer risk. Overall, epidemiological studies [1,2,3,4] have reported no substantial association between cigarette smoking and the risk of breast cancer. Some studies [5,6,7] reported a significant increase of breast cancer risk among smokers. In recent studies that addressed the association between breast cancer and cigarette smoking, however, there was some suggestion of a decreased risk [8,9,10], especially among current smokers, ranging from approximately 10 to 30% [9,10]. Brunet et al [11] reported that smoking might reduce the risk of breast cancer by 44% in carriers of BRCA1 or BRCA2 gene mutations. Wolfe [12] described four different mammographic patterns created by variations in the relative amounts of fat, epithelial and connective tissue in the breast, designated N1, P1, P2 and DY. Women with either P2 or DY pattern are considered at greater risk for breast cancer than those with N1 or P1 pattern [12

  4. Feature extraction from mammographic images using fast marching methods

    International Nuclear Information System (INIS)

    Bottigli, U.; Golosio, B.

    2002-01-01

    Features extraction from medical images represents a fundamental step for shape recognition and diagnostic support. The present work faces the problem of the detection of large features, such as massive lesions and organ contours, from mammographic images. The regions of interest are often characterized by an average grayness intensity that is different from the surrounding. In most cases, however, the desired features cannot be extracted by simple gray level thresholding, because of image noise and non-uniform density of the surrounding tissue. In this work, edge detection is achieved through the fast marching method (Level Set Methods and Fast Marching Methods, Cambridge University Press, Cambridge, 1999), which is based on the theory of interface evolution. Starting from a seed point in the shape of interest, a front is generated which evolves according to an appropriate speed function. Such function is expressed in terms of geometric properties of the evolving interface and of image properties, and should become zero when the front reaches the desired boundary. Some examples of application of such method to mammographic images from the CALMA database (Nucl. Instr. and Meth. A 460 (2001) 107) are presented here and discussed

  5. Software planning and analysis for automated design system AutoCAD

    OpenAIRE

    Koskutė, Lina

    2007-01-01

    AutoCAD sistemos papildymas sukurtas tam, kad būtų lengviau ir paprasčiau dirbti su AutoCAD grafine sistema. Funkcijos sukurtos naudojant AutoLisp ir VisualLISP programavimo kalbas. Sistemos papildymą galima įdiegti į bet kurią AutoCAD versiją. Sukurtas papildymas lankstus naujų funkcijų prijungimui, lengvai eksploatuojamas. Funkcijos suskirstytos į keletą grupių pagal jų formatą. AutoCAD system complement is created to make more easy working with AutoCAD graphic system. Functions are crea...

  6. The combined effect of mammographic texture and density on breast cancer risk: a cohort study.

    Science.gov (United States)

    Wanders, Johanna O P; van Gils, Carla H; Karssemeijer, Nico; Holland, Katharina; Kallenberg, Michiel; Peeters, Petra H M; Nielsen, Mads; Lillholm, Martin

    2018-05-02

    Texture patterns have been shown to improve breast cancer risk segregation in addition to area-based mammographic density. The additional value of texture pattern scores on top of volumetric mammographic density measures in a large screening cohort has never been studied. Volumetric mammographic density and texture pattern scores were assessed automatically for the first available digital mammography (DM) screening examination of 51,400 women (50-75 years of age) participating in the Dutch biennial breast cancer screening program between 2003 and 2011. The texture assessment method was developed in a previous study and validated in the current study. Breast cancer information was obtained from the screening registration system and through linkage with the Netherlands Cancer Registry. All screen-detected breast cancers diagnosed at the first available digital screening examination were excluded. During a median follow-up period of 4.2 (interquartile range (IQR) 2.0-6.2) years, 301 women were diagnosed with breast cancer. The associations between texture pattern scores, volumetric breast density measures and breast cancer risk were determined using Cox proportional hazard analyses. Discriminatory performance was assessed using c-indices. The median age of the women at the time of the first available digital mammography examination was 56 years (IQR 51-63). Texture pattern scores were positively associated with breast cancer risk (hazard ratio (HR) 3.16 (95% CI 2.16-4.62) (p value for trend <0.001), for quartile (Q) 4 compared to Q1). The c-index of texture was 0.61 (95% CI 0.57-0.64). Dense volume and percentage dense volume showed positive associations with breast cancer risk (HR 1.85 (95% CI 1.32-2.59) (p value for trend <0.001) and HR 2.17 (95% CI 1.51-3.12) (p value for trend <0.001), respectively, for Q4 compared to Q1). When adding texture measures to models with dense volume or percentage dense volume, c-indices increased from 0.56 (95% CI 0.53-0.59) to 0

  7. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  8. CAD/CAM/CNC.

    Science.gov (United States)

    Domermuth, Dave; And Others

    1996-01-01

    Includes "Quick Start CNC (computer numerical control) with a Vacuum Filter and Laminated Plastic" (Domermuth); "School and Industry Cooperate for Mutual Benefit" (Buckler); and "CAD (computer-assisted drafting) Careers--What Professionals Have to Say" (Skinner). (JOW)

  9. Volumetric breast density affects performance of digital screening mammography

    OpenAIRE

    Wanders, JO; Holland, K; Veldhuis, WB; Mann, RM; Pijnappel, RM; Peeters, PH; Van Gils, CH; Karssemeijer, N

    2016-01-01

    PURPOSE: To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). METHODS: We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the Ameri...

  10. Mammographic breast density in recent and longer-standing ethiopian immigrants to israel.

    Science.gov (United States)

    Sklair-Levy, Miri; Segev, Anat; Sella, Tamar; Calderon-Margalit, Ronit; Zippel, Douglas

    2018-04-23

    High breast density is associated with an increased risk of breast cancer development. Little is known concerning ethnic variations in breast density and its relevant contributing factors. We aimed to study breast density among Ethiopian immigrants to Israel in comparison with Israeli-born women and to determine any effect on breast density of the length of residency in the immigrant population. Mammographic breast density using the BI-RADS system was estimated and compared between 77 women of Ethiopian origin who live in Israel and 177 Israeli-born controls. Logistic regression analysis was performed to estimate the odds ratios (OR) for high density (BI-RADS score ≥ 3) vs low density (BI-RADS score density compared with Israeli-born women. Adjustments for various cofounders did not affect the results. Time since immigration to Israel seemed to modify the relationship, with a stronger association for women who immigrated within 2 years prior to mammography (OR:0.07, 95% CI: 0.03-0.17) as opposed to women with a longer residency stay in Israel (OR:0.23, 95% CI:0.10-0.50). Adjustments of various confounders did not alter these findings. Breast density in Ethiopian immigrants to Israel is significantly lower than that of Israeli-born controls. Our study suggests a positive association between time since immigration and breast density. Future studies are required to define the possible effects of dietary change on mammographic density following immigration. © 2018 Wiley Periodicals, Inc.

  11. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    Science.gov (United States)

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p manufacture of four-unit FDPs.

  12. Implications of unchanged detection criteria with CAD as second reader of mammograms

    International Nuclear Information System (INIS)

    Bornefalk, Hans

    2006-01-01

    In this paper we address the use of computer-aided detection (CAD) systems as second readers in mammography. The approach is based on Bayesian decision theory and its implication for the choice of optimal operating points. The choice of a certain operating point along an ROC curve corresponds to a particular tradeoff between false positives and missed cancers. By minimizing a total risk function given this tradeoff, we determine optimal decision thresholds for the radiologist and CAD system when CAD is used as a second reader. We show that under very general circumstances, the performance of the sequential system is improved if the decision threshold of the latent human decision variable is increased compared to what it would have been in the absence of the CAD system. This means that an initial stricter decision criterion should be applied by the radiologist when CAD is used as a second reader than otherwise. First and foremost, the results in this paper should be interpreted qualitatively, but an attempt is made at quantifying the effect by tuning the model to a prospective study evaluating the use of CAD as a second reader. By making some necessary and plausible assumptions, we are able to estimate the effect of the resulting suboptimal operating point. In this study of 12 860 women, we estimate that a 15% reduction in callbacks for masses could have been achieved with only about a 1.5% relative decrease in sensitivity compared to that without using a stricter initial criterion by the radiologist. For microcalcifications the corresponding values are 7% and 0.2%

  13. Customizing CAD system and its application for engineering design

    International Nuclear Information System (INIS)

    Shin, Jeong Ho; Kwak, Byung Man

    2003-01-01

    The computer is an important tool to design an engineering system and CAD systems are widely used for various design practice. To meet the market requirements, the old mass production system is being changed into the mass customization system. As for CAD systems, it is increasingly required to extend, automate, and customize a wide range of functionality. This article describes the state-of-the-art of the principal technologies for customizing CAD systems. And we have implemented an application that enables the parametric design by directly inputting numerical values of parameters for a CAD model. Based on this application, we have developed another system that makes it possible sharing of part family data between SolidEdge and Pro/Engineer. Through customization of CAD systems, it is possible to improve the product quality using external knowledge-based systems or to integrate with external system such as CAE tools. This paper can be a guide for engineering designers who want to customize CAD systems

  14. Performance of CAD/CAM fabricated fiber posts in oval-shaped root canals: An in vitro study.

    Science.gov (United States)

    Tsintsadze, Nino; Juloski, Jelena; Carrabba, Michele; Tricarico, Marella; Goracci, Cecilia; Vichi, Alessandro; Ferrari, Marco; Grandini, Simone

    2017-10-01

    To assess the push-out strength, the cement layer thickness and the interfacial nanoleakage of prefabricated fiber posts, CAD/CAM fiber posts and metal cast posts cemented into oval-shaped root canals. Oval-shaped post spaces were prepared in 30 single-rooted premolars. Roots were randomly assigned to three groups (n=10), according to the post type to be inserted: Group 1: Prefabricated fiber post (D.T. Light-Post X-RO Illusion); Group 2: Cast metal post; Group 3: CAD/CAM-fabricated fiber post (experimental fiber blocks). In Group 3, post spaces were sprayed with scan powder (VITA), scanned with an inEos 4.2 scanner, and fiber posts were milled using an inLab MC XL CAD/CAM milling unit. All posts were cemented using Gradia Core dual-cure resin cement in combination with Gradia core self-etching bond (GC). After 24 hours, the specimens were sectioned perpendicular to the long axis into six 1 mm-thick sections, which were differentiated by the root level. Sections from six roots per group were used to measure the cement thickness and subsequently for the thin-slice push-out test, whereas the sections from the remaining four teeth were assigned to interfacial nanoleakage test. The cement thickness around the posts was measured in micrometers (µm) on the digital images acquired with a digital microscope using the Digimizer software. Thin-slice push-out test was conducted using a universal testing machine at the crosshead speed of 0.5 mm/minute and the bond strength was expressed in megaPascals (MPa). The interfacial nanoleakage was observed under light microscope and quantified by scoring the depth of silver nitrate penetration along the post-cement-dentin interfaces. The obtained results were statistically analyzed by Kruskal-Wallis ANOVA, followed by the Dunn's Multiple Range test for post hoc comparisons. The level of significance was set at PCAD/CAM-fabricated fiber posts achieved retention that was comparable to that of cast metal posts and significantly higher

  15. Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S. R.; Bisogni, M. G.; Delogu, P.; Fantacci, M. E.; Paternoster, G.; Rosso, V.; Stefanini, A. [Str. Dip. di Matematica e Fisica dell' Universita di Sassari, Via Vienna 2, I-07100, Sassari (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy)

    2009-04-15

    The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power spectrum, and the detective quantum efficiency (DQE) have been measured following the guidelines of the IEC 62220-1-2 protocol. The transfer function analysis has shown the high spatial resolution capabilities of the GaAs detectors. The MTF calculated at the Nyquist frequency (2.94 cycles/mm) is indeed 60%. The DQE, measured with a standard mammographic beam setup (Mo/Mo, 28 kVp, with 4 mm Al added filter) and calculated at zero frequency, is 46%. Aiming to further improve the system's image quality, the authors investigate the DQE limiting factors and show that they are mainly related to system engineering. For example, the authors show that optimization of the image equalization procedure increases the DQE(0) up to 74%, which is better than the DQE(0) of most clinical mammographic systems. The authors show how the high detection efficiency of GaAs detectors and the noise discrimination associated with the SPC technology allow optimizing the image quality in mammography. In conclusion, the authors propose technological solutions to exploit to the utmost the potentiality of GaAs detectors coupled to SPC electronics.

  16. Textural Classification of Mammographic Parenchymal Patterns with the SONNET Selforganizing Neural Network

    Directory of Open Access Journals (Sweden)

    Daniel Howard

    2008-01-01

    Full Text Available In nationwide mammography screening, thousands of mammography examinations must be processed. Each consists of two standard views of each breast, and each mammogram must be visually examined by an experienced radiologist to assess it for any anomalies. The ability to detect an anomaly in mammographic texture is important to successful outcomes in mammography screening and, in this study, a large number of mammograms were digitized with a highly accurate scanner; and textural features were derived from the mammograms as input data to a SONNET selforganizing neural network. The paper discusses how SONNET was used to produce a taxonomic organization of the mammography archive in an unsupervised manner. This process is subject to certain choices of SONNET parameters, in these numerical experiments using the craniocaudal view, and typically produced O(10, for example, 39 mammogram classes, by analysis of features from O(103 mammogram images. The mammogram taxonomy captured typical subtleties to discriminate mammograms, and it is submitted that this may be exploited to aid the detection of mammographic anomalies, for example, by acting as a preprocessing stage to simplify the task for a computational detection scheme, or by ordering mammography examinations by mammogram taxonomic class prior to screening in order to encourage more successful visual examination during screening. The resulting taxonomy may help train screening radiologists and conceivably help to settle legal cases concerning a mammography screening examination because the taxonomy can reveal the frequency of mammographic patterns in a population.

  17. Unsupervised deep learning applied to breast density segmentation and mammographic risk scoring

    DEFF Research Database (Denmark)

    Kallenberg, Michiel Gijsbertus J.; Petersen, Peter Kersten; Nielsen, Mads

    2016-01-01

    Mammographic risk scoring has commonly been automated by extracting a set of handcrafted features from mammograms, and relating the responses directly or indirectly to breast cancer risk. We present a method that learns a feature hierarchy from unlabeled data. When the learned features are used...... as the input to a simple classifier, two different tasks can be addressed: i) breast density segmentation, and ii) scoring of mammographic texture. The proposed model learns features at multiple scales. To control the models capacity a novel sparsity regularizer is introduced that incorporates both lifetime...... and population sparsity. We evaluated our method on three different clinical datasets. Our state-of-the-art results show that the learned breast density scores have a very strong positive relationship with manual ones, and that the learned texture scores are predictive of breast cancer. The model is easy...

  18. Mammographic Texture Resemblance generalizes as an independent risk factor of breast cancer

    DEFF Research Database (Denmark)

    Chernoff, Konstantin; Christopher, S G; Karemore, Gopal

    PURPOSE Breast density has been established as a risk factor of breast cancer in numerous studies. Mammographic Texture Resemblance (MTR) has shown to be a density independent risk factor, but only on a single study. We examine if the statistics of the texture recorded in one study generalize...... as an independent risk factor in an unrelated cohort. METHOD AND MATERIALS The statistics of texture were recorded in digitalized film-mammograms of one 4-year prospective study (S1, Dutch screening program) of 245 breast cancers and 250 matched controls. From an independent cohort study (S2, Mayo Mammography...... Health Study cohort) 226 incident breast cancer cases diagnosed through 2008 and 442 matched controls (on age) were used for scoring screening digitized mammograms that were ascertained years prior to diagnosis 1993-2006. Mammographic percent density (PD), using Cumulus, and other major risk factors were...

  19. Mammographic Features of Local Recurrence after Conservative Surgery and Radiation Therapy: Comparison with that of the Primary Tumor

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, I.; Oktay, A.

    2007-01-01

    Purpose: To compare the mammographic features of recurrent breast cancer with those of the primary tumor and to determine whether certain mammographic features are associated with a higher risk of local recurrence after breast-conserving therapy. Material and Methods: A retrospective review of mammograms of 421 patients who were treated with conservative surgery and radiotherapy revealed 41 recurrent tumors. Mammographic findings, location, and histopathologic characteristics were retrospectively compared between primary and recurrent tumors. Results: Recurrent tumors were similar in mammographic appearance to primary tumors in 27 (66%) cases. Of 27 primary tumors that occurred as masses without calcifications, 19 (70%) recurred as a mass, and of the six isolated calcifications, five (83%) recurred with calcifications. Ten (53%) of the 19 recurrent masses and five (100%) of the five recurrent calcifications had morphologic features that were similar to those of the primary tumor. Ninety-two percent (11/12) of the recurrences containing microcalcifications (isolated or associated with a mass) had microcalcifications in their primary tumor. Of 27 masses that recurred, the morphology of the primary tumor was obscured in 13 (48%), ill defined in 10 (37%), and spiculated in four (15%) of the masses. Seventy-six percent (31/41) of recurrences were within the lumpectomy quadrant. In 25 (61%) cases, the histologic findings from the primary tumor and the recurrence were identical. Conclusion: The majority of recurrent tumors appear to be mammographically similar to primary tumors. Therefore, it is important to review preoperative mammograms during follow-up of these patients. Although the study population is small, it was noted that mass with spiculated contour is associated with a lower risk for local recurrence

  20. Mammographic features and misdiagnosed analysis on 92 cases with breast cancer

    International Nuclear Information System (INIS)

    Liu Mingjuan; Zhang Xiaoling; Guo Yan

    2010-01-01

    Objective: To investigate the atypical X-ray features in breast cancer and improve the accuracy of diagnosis. Methods: Mammographic features of 92 cases with pathologically confirmed breast cancer were analyzed retrospectively. Results: High-density mass with speculated margined, clusters of small calcification, stellate-like lesions were found in 51 cases, the rate of correct diagnosis was 96%-100%. Lobulated high-density mass were found in 17 cases, the correct diagnosis rate was about 88.3% cases with skin thickening were all correctly diagnosed. Round mass, focal parenchymal asymmetry and unidentified lesions were found in 20 cases, the diagnosing rate was less than 20%. Conclusion: Round mass, focal parenchymal asymmetry and unidentified lesions were atypical mammographic features of breast cancer. These lesions were misdiagnosed frequently. It is essential to find the indirect signs and associated finding to avoid misdiagnosis. On the other hand, further ultrasound or MRI were helpful to improve the diagnosis by detecting mass in breast, showing cystic lesions and blood supply. (authors)

  1. XML-based assembly visualization for a multi-CAD digital mock-up system

    International Nuclear Information System (INIS)

    Song, In Ho; Chung, Sung Chong

    2007-01-01

    Using a virtual assembly tool, engineers are able to design accurate and interference free parts without making physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product in a distributed design environment. In this paper, a multi-CAD assembly method is proposed through an XML and the lightweight CAD file. XML data contains a hierarchy of the multi-CAD assembly. The lightweight CAD file produced from various CAD files through the ACIS kemel and InterOp includes not only mesh and B-Rep data, but also topological data. It is used to visualize CAD data and to verify dimensions of the parts. The developed system is executed on desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Multi-CAD models have been assembled to verify the effectiveness of the developed DMU system on the Internet

  2. TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Hoffman, J; Kim, H; Hsu, W; Flores, C; Lee, G; Brown, M; McNitt-Gray, M

    2016-01-01

    Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens

  3. TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Hoffman, J; Kim, H; Hsu, W; Flores, C; Lee, G; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens

  4. Sharing the learning activity using intelligent CAD

    DEFF Research Database (Denmark)

    Duffy, S. M.; Duffy, Alex

    1996-01-01

    In this paper the need for Intelligent Computer Aided Design (Int.CAD) to jointly support design and learning assistance is introduced. The paper focuses on presenting and exploring the possibility of realizing ''learning'' assistance in Int.CAD by introducing a new concept called Shared Learning...

  5. International Consortium on Mammographic Density: Methodology and Population Diversity captured across 22 Countries

    Science.gov (United States)

    McCormack, Valerie A.; Burton, Anya; dos-Santos-Silva, Isabel; Hipwell, John H.; Dickens, Caroline; Salem, Dorria; Kamal, Rasha; Hartman, Mikael; Ling Lee, Charmaine Pei; Chia, Kee-Seng; Ozmen, Vahit; Aribal, Mustafa Erkin; Flugelman, Anath Arzee; Lajous, Martín; Lopez-Riduara, Ruy; Rice, Megan; Romieu, Isabelle; Ursin, Giske; Qureshi, Samera; Ma, Huiyan; Lee, Eunjung; van Gils, Carla H.; Wanders, Johanna O.P.; Vinayak, Sudhir; Ndumia, Rose; Allen, Steve; Vinnicombe, Sarah; Moss, Sue; Lee, Jong Won; Kim, Jisun; Pereira, Ana; Garmendia, Maria Luisa; Sirous, Reza; Sirous, Mehri; Peplonska, Beata; Bukowska, Agnieszka; Tamimi, Rulla M.; Bertrand, Kimberly; Nagata, Chisato; Kwong, Ava; Vachon, Celine; Scott, Christopher; Perez-Gomez, Beatriz; Pollan, Marina; Maskarinec, Gertraud; Giles, Graham; Hopper, John; Stone, Jennifer; Rajaram, Nadia; Teo, Soo-Hwang; Mariapun, Shivaani; Yaffe, Martin J.; Schüz, Joachim; Chiarelli, Anna; Linton, Linda; Boyd, Norman F.

    2015-01-01

    Mammographic density (MD) is a quantitative trait, measurable in all women, and is among the strongest markers of breast cancer risk. The population-based epidemiology of MD has revealed genetic, lifestyle and societal/environmental determinants, but studies have largely been conducted in women with similar westernized lifestyles living in countries with high breast cancer incidence rates. To benefit from the heterogeneity in risk factors and their combinations worldwide, we created an International Consortium on Mammographic Density (ICMD) to pool individual-level epidemiological and MD data from general population studies worldwide. ICMD aims to characterize determinants of MD more precisely, and to evaluate whether they are consistent across populations worldwide. We included 11755 women, from 27 studies in 22 countries, on whom individual-level risk factor data were pooled and original mammographic images were re-read for ICMD by a core team to obtain standardized comparable MD data. In the present article, we present (i) the rationale for this consortium; (ii) characteristics of the studies and women included; and (iii) study methodology to obtain comparable MD data from original re-read films. We also highlight the risk factor heterogeneity captured by such an effort and, thus, the unique insight the pooled study promises to offer through wider exposure ranges, different confounding structures and enhanced power for sub-group analyses. PMID:26724463

  6. Identification of two novel mammographic density loci at 6Q25.1.

    Science.gov (United States)

    Brand, Judith S; Li, Jingmei; Humphreys, Keith; Karlsson, Robert; Eriksson, Mikael; Ivansson, Emma; Hall, Per; Czene, Kamila

    2015-06-03

    Mammographic density (MD) is a strong heritable and intermediate phenotype for breast cancer, but much of its genetic variation remains unexplained. We performed a large-scale genetic association study including 8,419 women of European ancestry to identify MD loci. Participants of three Swedish studies were genotyped on a custom Illumina iSelect genotyping array and percent and absolute mammographic density were ascertained using semiautomated and fully automated methods from film and digital mammograms. Linear regression analysis was used to test for SNP-MD associations, adjusting for age, body mass index, menopausal status and six principal components. Meta-analyses were performed by combining P values taking sample size, study-specific inflation factor and direction of effect into account. Genome-wide significant associations were observed for two previously identified loci: ZNF365 (rs10995194, P = 2.3 × 10(-8) for percent MD and P = 8.7 × 10(-9) for absolute MD) and AREG (rs10034692, P = 6.7 × 10(-9) for absolute MD). In addition, we found evidence of association for two variants at 6q25.1, both of which are known breast cancer susceptibility loci: rs9485370 in the TAB2 gene (P = 4.8 × 10(-9) for percent MD and P = 2.5 × 10(-8) for absolute MD) and rs60705924 in the CCDC170/ESR1 region (P = 2.2 × 10(-8) for absolute MD). Both regions have been implicated in estrogen receptor signaling with TAB2 being a potential regulator of tamoxifen response. We identified two novel MD loci at 6q25.1. These findings underscore the importance of 6q25.1 as a susceptibility region and provide more insight into the mechanisms through which MD influences breast cancer risk.

  7. Automation in the Teaching of Descriptive Geometry and CAD. High-Level CAD Templates Using Script Languages

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study improvements to the learning method of technical drawing and descriptive geometry through exercises with traditional techniques that are usually solved manually by applying automated processes assisted by high-level CAD templates (HLCts). Given that an exercise with traditional procedures can be solved, detailed step by step in technical drawing and descriptive geometry manuals, CAD applications allow us to do the same and generalize it later, incorporating references. Traditional teachings have become obsolete and current curricula have been relegated. However, they can be applied in certain automation processes. The use of geometric references (using variables in script languages) and their incorporation into HLCts allows the automation of drawing processes. Instead of repeatedly creating similar exercises or modifying data in the same exercises, users should be able to use HLCts to generate future modifications of these exercises. This paper introduces the automation process when generating exercises based on CAD script files, aided by parametric geometry calculation tools. The proposed method allows us to design new exercises without user intervention. The integration of CAD, mathematics, and descriptive geometry facilitates their joint learning. Automation in the generation of exercises not only saves time but also increases the quality of the statements and reduces the possibility of human error.

  8. Comparison of 3MP medical-grade to 1MP office grade LCD monitors in mammographic diagnostic and perceptual performance

    International Nuclear Information System (INIS)

    Ong, Aaron; Tan, Shu.; Gledhill, Samuel; Hennessy, Oliver; Lui, Belinda; Lee, Alan; Lemish, Wayne; Styles, Colin; Pun, Emma; Padmanabhan, Meenakshi; Pitman, Alexander G.; Tauro, Paul; Waugh, Paul

    2011-01-01

    Full text: Picture archiving and communication systems images designed to be viewed on high-resolution medical-grade monitors are routinely viewed on office-grade monitors on the wards or at home. This study aimed to determine whether a statistically significant difference in diagnostic (cancer detection) and perceptual (microcalcification detection) performance exists between 3MP grade and 1MP office-grade monitors. 3MP Dome medical-grade liquid crystal display (LCD) monitors (Planar, Beaverton, OR, USA) were compared to 1MP Dell office-grade LCD monitors (Dell Inc, Round Rock, TX, USA). Eight radiologists (reader experi ence 8-30 years) read the same set of 100 mammograms (23/100 with proven cancers and 52/100 with microcalcifications) presented in random order on three occasions separated by two time intervals of 12 weeks. Reads 1 and 3 utilised 3MP monitors and formed the baseline read. Read 2 utilised 1MP monitors and constituted the experimental read. Reading conditions were standardised. Readers were aware of which monitors they were using. Mul tivariate logistic regression analysis (to account for reader variability and monitor impact) was performed to assess for statistical significance. At a = 5%, confidence intervals analysis comparing the measured parameters between 1MP to 3MP monitors demonstrated no statistically significant difference in diagnostic and perceptual performance for the reader group. In cancer detection (the diagnostic task), reader accuracy remained high irrespective of monitor type. Regression analysis comparing performance with 1MP against 3MP monitors found P values of 0.693 and 0.324 for diagnostic and perceptual performance, respectively. There were no statistically and clinically significant differences between 3MP and 1MP monitors in mammographic diagnostic and perceptual performance. Comparable performance may be due to compensatory behav iour by readers.

  9. AutoCAD platform customization user interface, AutoLISP, VBA, and beyond

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Take control of AutoCAD to boost the speed, quality, and precision of your work Senior drafters and savvy users are increasingly taking AutoCAD customization out of the hands of system administrators, and taking control of their own workflow. In AutoCAD Platform Customization, Autodesk customization guru Lee Ambrosius walks you through a multitude of customization options using detailed tutorials and real-world examples applicable to AutoCAD, AutoCAD LT, Civil 3D, Plant 3D, and other programs built on the AutoCAD platform. By unleashing the full power of the software, you'll simplify and str

  10. AutoCAD-To-NASTRAN Translator Program

    Science.gov (United States)

    Jones, A.

    1989-01-01

    Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).

  11. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Mark, E-mail: marktknox@gmail.com; O’Brien, Angela, E-mail: angelaobrien@doctors.org.uk; Szabó, Endre, E-mail: endrebacsi@freemail.hu; Smith, Clare S., E-mail: csmith@mater.ie; Fenlon, Helen M., E-mail: helen.fenlon@cancerscreening.ie; McNicholas, Michelle M., E-mail: michelle.mcnicholas@cancerscreening.ie; Flanagan, Fidelma L., E-mail: fidelma.flanagan@cancerscreening.ie

    2015-06-15

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications.

  12. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    International Nuclear Information System (INIS)

    Knox, Mark; O’Brien, Angela; Szabó, Endre; Smith, Clare S.; Fenlon, Helen M.; McNicholas, Michelle M.; Flanagan, Fidelma L.

    2015-01-01

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications

  13. Edge strength of CAD/CAM materials.

    Science.gov (United States)

    Pfeilschifter, Maria; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-05-16

    To investigate the edge force of CAD/CAM materials as a function of (a) material, (b) thickness, and (c) distance from the margin. Materials intended for processing with CAD/CAM were investigated: eight resin composites, one resin-infiltrated ceramic, and a clinically proven lithiumdisilicate ceramic (reference). To measure edge force (that is, load to failure/crack), plates (d = 1 mm) were fixed and loaded with a Vickers diamond indenter (1 mm/min, Zwick 1446) at a distance of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm from the edge. Edge force was defined as a loading force at a distance of 0.5 mm. The type of failure was determined. To investigate the influence of the thickness, all data were determined on 1-mm and 2-mm plates. To test the influence of bonding and an underlying dentin, individual 1-mm plates were bonded to a 1-mm-thick dentin-like (concerning modulus of elasticity) resin composite. For the 1-mm plates, edge force varied between 64.4 ± 24.2 N (Shofu Block HC) and 183.2 ± 63.3 N (ceramic reference), with significant (p ≤ 0.001) differences between the materials. For the 2-mm plates, values between 129.2 ± 32.5 N (Lava Ultimate) and 230.3 ± 67.5 N (Cerasmart) were found. Statistical comparison revealed no significant differences (p > 0.109) between the materials. Brilliant Crios (p = 0.023), Enamic (p = 0.000), Shofu Blocks HC (p = 0.009), and Grandio Bloc (p = 0.002) showed significantly different edge force between the 1-mm- and 2-mm-thick plates. The failure pattern was either cracking, (severe) chipping, or fracture. Material, material thickness, and distance from the edge impact the edge force of CAD/CAM materials. CAD/CAM materials should be carefully selected on the basis of their individual edge force and performance during milling. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Functional characterization of a cadmium resistance operon in Staphylococcus aureus ATCC12600: CadC does not function as a repressor.

    Science.gov (United States)

    Hoogewerf, Arlene J; Dyk, Lisa A Van; Buit, Tyler S; Roukema, David; Resseguie, Emily; Plaisier, Christina; Le, Nga; Heeringa, Lee; Griend, Douglas A Vander

    2015-02-01

    Sequencing of a cadmium resistance operon from a Staphylococcus aureus ATCC12600 plasmid revealed that it is identical to a cadCA operon found in MRSA strains. Compared to plasmid-cured and cadC-mutant strains, cadC-positive ATCC12600 cells had increased resistance to cadmium (1 mg ml(-1) cadmium sulfate) and zinc (4 mg ml(-1) zinc sulfate), but not to other metal ions. After growth in media containing 20 µg ml(-1) cadmium sulfate, cadC-mutant cells contained more intracellular cadmium than cadC-positive ATCC12600 cells, suggesting that cadC absence results in impaired cadmium efflux. Electrophoretic mobility shift assays were performed with CadC proteins encoded by the S. aureus ATCC12600 plasmid and by the cadC gene of pI258, which is known to act as a transcriptional repressor and shares only 47% protein sequence identity with ATCC12600 CadC. Mobility shifts occurred when pI258 CadC protein was incubated with the promoter DNA-regions from the pI258 and S. aureus ATCC12600 cadCA operons, but did not occur with S. aureus ATCC12600 CadC protein, indicating that the ATCC12600 CadC protein does not interact with promoter region DNA. This cadCA operon, found in MRSA strains and previously functionally uncharacterized, increases resistance to cadmium and zinc by an efflux mechanism, and CadC does not function as a transcriptional repressor. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Cigarette smoking and mammographic density in the Danish Diet, Cancer and Health cohort

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp; Lynge, Elsebeth; Vejborg, Ilse

    2016-01-01

    with MD. METHODS: For the 5,356 women (4,489 postmenopausal) from the Danish Diet, Cancer and Health cohort (1993-1997) who attended mammographic screening in Copenhagen (1993-2001), we used MD (mixed/dense or fatty) assessed at the first screening after cohort entry. Active smoking (status, duration......PURPOSE: Smoking before first childbirth increases breast cancer risk, but the biological mechanism remains unknown and may involve mammographic density (MD), one of the strongest biomarkers of breast cancer risk. We aimed to examine whether active smoking and passive smoking were associated......, and intensity) and passive smoking were assessed at cohort baseline (1993-1997) via questionnaire, together with other breast cancer risk factors. Logistic regression was used to estimate associations (odds ratios, 95 % confidence intervals) between smoking and MD, adjusting for confounders. RESULTS: Two...

  16. Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography

    International Nuclear Information System (INIS)

    Ciatto, Stefano; Del Turco, Marco Rosselli; Risso, Gabriella; Catarzi, Sandra; Bonardi, Rita; Viterbo, Valeria; Gnutti, Pierangela; Guglielmoni, Barbara; Pinelli, Lelio; Pandiscia, Anna; Navarra, Francesco; Lauria, Adele; Palmiero, Rosa; Indovina, Pietro Luigi

    2003-01-01

    Objective: To evaluate the role of computer aided detection (CAD) in improving the interpretation of screening mammograms Material and methods: Ten radiologists underwent a proficiency test of screening mammography first by conventional reading and then with the help of CAD. Radiologists were blinded to test results for the whole study duration. Results of conventional and CAD reading were compared in terms of sensitivity and recall rate. Double reading was simulated combining conventional readings of four expert radiologists and compared with CAD reading. Results: Considering all ten readings, cancer was identified in 146 or 153 of 170 cases (85.8 vs. 90.0%; χ 2 =0.99, df=1, P=0.31) and recalls were 106 or 152 of 1330 cases (7.9 vs. 11.4%; χ 2 =8.69, df=1, P=0.003) at conventional or CAD reading, respectively. CAD reading was essentially the same (sensitivity 97.0 vs. 96.0%; χ 2 =7.1, df=1, P=0.93; recall rate 10.7 vs. 10.6%; χ 2 =1.5, df=1, P=0.96) as compared with simulated conventional double reading. Conclusion: CAD reading seems to improve the sensitivity of conventional reading while reducing specificity, both effects being of limited size. CAD reading had almost the same performance of simulated conventional double reading, suggesting a possible use of CAD which needs to be confirmed by further studies inclusive of cost-effective analysis

  17. CAD-centric Computation Management System for a Virtual TBM

    Energy Technology Data Exchange (ETDEWEB)

    Ramakanth Munipalli; K.Y. Szema; P.Y. Huang; C.M. Rowell; A.Ying; M. Abdou

    2011-05-03

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  18. Mammographic compression – A need for mechanical standardization

    Energy Technology Data Exchange (ETDEWEB)

    Branderhorst, Woutjan, E-mail: w.branderhorst@amc.nl [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Sigmascreening B.V., Meibergdreef 45, 1105 BA Amsterdam (Netherlands); Groot, Jerry E. de, E-mail: jerry.degroot@sigmascreening.com [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Highnam, Ralph, E-mail: ralph.highnam@volparasolutions.com [Volpara Solutions Limited, P.O. Box 24404, Manners St Central, Wellington 6142 (New Zealand); Chan, Ariane, E-mail: ariane.chan@volparasolutions.com [Volpara Solutions Limited, P.O. Box 24404, Manners St Central, Wellington 6142 (New Zealand); Böhm-Vélez, Marcela, E-mail: marcelabvelez@gmail.com [Weinstein Imaging Associates, 5850 Centre Avenue, Pittsburgh, PA 15206 (United States); Broeders, Mireille J.M., E-mail: mireille.broeders@radboudumc.nl [Radboud University Medical Center, Department for Health Evidence, P.O. Box 9101, 6500 HB Nijmegen (Netherlands); LRCB Dutch Reference Center for Screening, P.O. Box 6873, 6503 GJ Nijmegen (Netherlands); Heeten, Gerard J. den, E-mail: g.denheeten@lrcb.nl [Academic Medical Center, Department of Radiology, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); LRCB Dutch Reference Center for Screening, P.O. Box 6873, 6503 GJ Nijmegen (Netherlands); Grimbergen, Cornelis A., E-mail: c.a.grimbergen@amc.uva.nl [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Sigmascreening B.V., Meibergdreef 45, 1105 BA Amsterdam (Netherlands)

    2015-04-15

    Highlights: •We studied mechanical breast compression practice in two different clinical sites. •We visualized the distributions of not only the applied force but also the pressure. •The applied pressure was highly variable, both within and between the data sets. •The average applied pressure and the variation were higher for smaller breasts. •A proposal for improved individualization, by standardizing pressure, is discussed. -- Abstract: Background: A lack of consistent guidelines regarding mammographic compression has led to wide variation in its technical execution. Breast compression is accomplished by means of a compression paddle, resulting in a certain contact area between the paddle and the breast. This procedure is associated with varying levels of discomfort or pain. On current mammography systems, the only mechanical parameter available in estimating the degree of compression is the physical entity of force (daN). Recently, researchers have suggested that pressure (kPa), resulting from a specific force divided by contact area on a breast, might be a more appropriate parameter for standardization. Software has now become available which enables device-independent cross-comparisons of key mammographic metrics, such as applied compression pressure (force divided by contact area), breast density and radiation dose, between patient populations. Purpose: To compare the current compression practice in mammography between different imaging sites in the Netherlands and the United States from a mechanical point of view, and to investigate whether the compression protocols in these countries can be improved by standardization of pressure (kPa) as an objective mechanical parameter. Materials and methods: We retrospectively studied the available parameters of a set of 37,518 mammographic compressions (9188 women) from the Dutch national breast cancer screening programme (NL data set) and of another set of 7171 compressions (1851 women) from a breast imaging

  19. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin

    2017-01-01

    PURPOSE To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (Pcementation of the novel CAD/CAM restorative materials. PMID:29279763

  20. The review of CAD for simulation of microwave devices

    Directory of Open Access Journals (Sweden)

    Drach V.E.

    2017-01-01

    Full Text Available the article is devoted to a brief review of modern CAD for electromagnetic modeling of microwave devices. Five major CAD systems are described in the article: FEKO, μWave Wizard, Sonnet, AWR Microwave Office, HFSS. The main methods are given for each CAD system used for simulation of microwave structures and the main advantages that distinguish its use.

  1. Geometric data transfer between CAD systems: solid models

    DEFF Research Database (Denmark)

    Kroszynski, Uri; Palstroem, Bjarne; Trostmann, Erik

    1989-01-01

    The first phase of the ESPRIT project CAD*I resulted in a specification for the exchange of solid models as well as in some pilot implementations of processors based on this specification. The authors summarize the CAD*I approach, addressing the structure of neutral files for solids, entities......, and attributes supporting three kinds of representations: facilities for the transfer of parametric designs; referencing library components; and other general mechanisms. They also describe the current state of the specification and processor implementations and include an example of a CAD*I neutral file....... Results from cycle and intersystem solid model transfer tests are presented, showing the practicality of the CAD*I proposal. B-rep model transfer results are discussed in some detail. The relationship of this work to standardization efforts is outlined...

  2. Resin-composite blocks for dental CAD/CAM applications.

    Science.gov (United States)

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  3. The mammographic spectrum of intraductal carcinoma

    International Nuclear Information System (INIS)

    Ikeda, D.M.; Andersson, I.

    1988-01-01

    To analyze the atypical radiographic spectrum of ductal carcinoma in situ (DCIS), the authors retrospectively reviewed the mammograms of 190 women who had biopsy-proved DCIS at Malmo General Hospital between January 1976 and March 1988. Of these, 117 (61.6%) showed clustered microcalcifications as the major abnormality, a finding often associated with DCIS. The remaining 73 women (38.4%) had either negative mammograms (30 women) or radiographic findings not usually associated with DCIS (43 women), including circumscribed masses (15 women) and focal conglomerates of prominent ducts and nodules (12 cases). Since treatment of DCIS may cure the disease, the radiologist should learn to recognize the more unusual mammographic manifestations of intraductal carcinoma

  4. Resolution effects on the morphology of calcifications in digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Kallergi, Maria; He, Li; Gavrielides, Marios; Heine, John; Clarke, Laurence P [Department of Radiology, College of Medicine, and H. Lee Moffitt Cancer Center and Research Institute at the University of South Florida, 12901 Bruce B. Downs Blvd., Box 17, Tampa, FL 33612 (United States)

    1999-12-31

    The development of computer assisted diagnosis (CAD) techniques and direct digital mammography systems have generated significant interest in the issue of the effect of image resolution on the detection and classification (benign vs malignant) of mammographic abnormalities. CAD in particular seems to heavily depend on image resolution, either due to the inherent algorithm design and optimization, which is almost always dependent, or due to the differences in image content at the various resolutions. This twofold dependence makes it even more difficult to answer the question of what is the minimum resolution required for successful detection and/or classification of a specific mammographic abnormality, such as calcifications. One may begin by evaluating the losses in the mammograms as the films are digitized with different pixel sizes and depths. In this paper we attempted to measure these losses for the case of calcifications at four different spatial resolutions through a simulation model and a classification scheme that is based only on morphological features. The results showed that a 60 {mu}m pixel size and 12 bits per pixel should at least be used if the morphology and distribution of the calcifications are essential components in the CAD algorithm design. These conclusions were tested with the use of a wavelet-based algorithm for the segmentation of simulated mammographic calcifications at various resolutions. The evaluation of the segmentation through shape analysis and classification supported the initial conclusion. (authors) 14 refs., 1 tabs.

  5. Roughness, surface energy, and superficial damages of CAD/CAM materials after surface treatment.

    Science.gov (United States)

    Strasser, Thomas; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-02-05

    The aim of this study was to examine the effects of surface pre-treatment on CAD/CAM materials including ceramics, zirconia, resin-infiltrated ceramic, and resin-based composite. Specimens were made of ten CAD/CAM materials (Celtra Duo, Degudent, D; Vita Suprinity, Vita, D; E.max CAD, Ivoclar-Vivadent, FL; E.max ZirCAD, Ivoclar-Vivadent, FL; Vita Enamic, Vita, D; Cerasmart, GC, B; LAVA Ultimate, 3M, D; SHOFU Block HC, SHOFU, US; Grandio Blocs, VOCO, D; BRILLIANT Crios, Coltene, CH) and pretreated to represent clinical procedures (Hf 20 s/5%; phosphoric acid 20 s/37%; Monobond etch and prime (Ivoclar-Vivadent, FL); water-cooled diamond bur (80 μm; 4 μm); Al 2 O 3 -blasting (50 μm/1 bar, 50 μm/2 bar, 120 μm/1 bar, 120 μm/2 bar); untreated; manufacturer's instructions). SEM-analysis (Phenom, FEI, NL) of the surfaces was performed (magnifications ≤ 10,000×). Roughness values R a , R z (KJ 3D, Keyence, J), and surface energy SE (OCA15 plus, SCA20, DataPhysics, D) were determined (statistics: non-parametric Mann-Whitney U test/Kruskal-Wallis test for independent specimen, α = 0.05). Kruskal-Wallis revealed significant (p CAD/CAM materials require individual pre-treatment for optimized and protective surface activation. Cementation is a key factor for clinical success. Given the variety of available CAD/CAM materials, specific procedures are needed.

  6. Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.

    Science.gov (United States)

    Buhmann, Sonja; Herzog, Peter; Liang, Jin; Wolf, Mathias; Salganicoff, Marcos; Kirchhoff, Chlodwig; Reiser, Maximilian; Becker, Christoph H

    2007-06-01

    To evaluate the performance of a prototype computer-aided diagnosis (CAD) tool using artificial intelligence techniques for the detection of pulmonary embolism (PE) and the possible benefit for general radiologists. Forty multidetector row computed tomography datasets (16/64- channel scanner) using 100 kVp, 100 mAs effective/slice, and 1-mm axial reformats in a low-frequency reconstruction kernel were evaluated. A total of 80 mL iodinated contrast material was injected at a flow rate of 5 mL/seconds. Primarily, six general radiologists marked any PE using a commercially available lung evaluation software with simultaneous, automatic processing by CAD in the background. An expert panel consisting of two chest radiologists analyzed all PE marks from the readers and CAD, also searching for additional finding primarily missed by both, forming the ground truth. The ground truth consisted of 212 emboli. Of these, 65 (31%) were centrally and 147 (69%) were peripherally located. The readers detected 157/212 emboli (74%) leading to a sensitivity of 97% (63/65) for central and 70% (103/147) for peripheral emboli with 9 false-positive findings. CAD detected 168/212 emboli (79%), reaching a sensitivity of 74% for central (48/65) and 82%(120/147) for peripheral emboli. A total of 154 CAD candidates were considered as false positives, yielding an average of 3.85 false positives/case. The CAD software showed a sensitivity comparable to that of the general radiologists, but with more false positives. CAD detection of findings incremental to the radiologists suggests benefit when used as a second reader. Future versions of CAD have the potential to further increase clinical benefit by improving sensitivity and reducing false marks.

  7. Fibrocystic change in breast; mammographic and ultrasonographic findings in lower risk lesions

    International Nuclear Information System (INIS)

    Kook, Shin Ho; Jung, Kyung Jae; Noh, In Gye

    1996-01-01

    We performed this study to define the characteristic mammographic and ultrasonographic findings in lower risk lesions of fibrocystic change and also tried to evaluate the role of both modalities in planning the treatment of these lesions. We retrospectively reviewed 38 cases of mammography and 46 cases of ultrasonography in biopsy proven 55 cases of fibrocystic change, histologically showing the nonproliferative pattern or proliferative pattern without atypia. We analyzed the mammographic and ultrasonographic findings, final assessments, and compared the effectiveness of each modality. On mammography, there were no abnormatlities in 20 cases(53%), nodules or masses in 9 cases(24%), microcalcifications in 6 cases(16%) and asymmetric density in 5 cases(14%). On ultrasonography, there were 40 cases(87%) of focal sonographic abnormality and no abnormality in 6 cases(13%). Most focal sonographic abnormalities were smooth(40 cases, 93%), well-defined(21 cases, 49%) or ill-defined(22 cases, 51%) round or oval(36 cases, 84%) shaped, homogeneous(31 cases, 67%), hypoechoic(30 cases, 65%) lesions. Final assessment revealed that only 7 cases(18%) of mammography and 8 cases(18%) of ultrasound examinations were included into the category of indeterminate and malignancy groups which were recommended biopsy. Mammography was excellent to demonstrate the microcalcifications and ultrasonography was effective in depiction of the focal lesions. The mammography and ultrasonography findings were not specific in diagnosing lower risk group of fibrocystic change. But complementary study of both modalities in conjunction with clinical findings will be helpful in making decision among biopsy, fine needle aspiration, and simple close follow up of the lesions

  8. Fibrocystic change in breast; mammographic and ultrasonographic findings in lower risk lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kook, Shin Ho; Jung, Kyung Jae; Noh, In Gye [Kangbuk Samsung Hospital, Seoul (Korea, Republic of)

    1996-01-01

    We performed this study to define the characteristic mammographic and ultrasonographic findings in lower risk lesions of fibrocystic change and also tried to evaluate the role of both modalities in planning the treatment of these lesions. We retrospectively reviewed 38 cases of mammography and 46 cases of ultrasonography in biopsy proven 55 cases of fibrocystic change, histologically showing the nonproliferative pattern or proliferative pattern without atypia. We analyzed the mammographic and ultrasonographic findings, final assessments, and compared the effectiveness of each modality. On mammography, there were no abnormatlities in 20 cases(53%), nodules or masses in 9 cases(24%), microcalcifications in 6 cases(16%) and asymmetric density in 5 cases(14%). On ultrasonography, there were 40 cases(87%) of focal sonographic abnormality and no abnormality in 6 cases(13%). Most focal sonographic abnormalities were smooth(40 cases, 93%), well-defined(21 cases, 49%) or ill-defined(22 cases, 51%) round or oval(36 cases, 84%) shaped, homogeneous(31 cases, 67%), hypoechoic(30 cases, 65%) lesions. Final assessment revealed that only 7 cases(18%) of mammography and 8 cases(18%) of ultrasound examinations were included into the category of indeterminate and malignancy groups which were recommended biopsy. Mammography was excellent to demonstrate the microcalcifications and ultrasonography was effective in depiction of the focal lesions. The mammography and ultrasonography findings were not specific in diagnosing lower risk group of fibrocystic change. But complementary study of both modalities in conjunction with clinical findings will be helpful in making decision among biopsy, fine needle aspiration, and simple close follow up of the lesions.

  9. CATO: a CAD tool for intelligent design of optical networks and interconnects

    Science.gov (United States)

    Chlamtac, Imrich; Ciesielski, Maciej; Fumagalli, Andrea F.; Ruszczyk, Chester; Wedzinga, Gosse

    1997-10-01

    Increasing communication speed requirements have created a great interest in very high speed optical and all-optical networks and interconnects. The design of these optical systems is a highly complex task, requiring the simultaneous optimization of various parts of the system, ranging from optical components' characteristics to access protocol techniques. Currently there are no computer aided design (CAD) tools on the market to support the interrelated design of all parts of optical communication systems, thus the designer has to rely on costly and time consuming testbed evaluations. The objective of the CATO (CAD tool for optical networks and interconnects) project is to develop a prototype of an intelligent CAD tool for the specification, design, simulation and optimization of optical communication networks. CATO allows the user to build an abstract, possible incomplete, model of the system, and determine its expected performance. Based on design constraints provided by the user, CATO will automatically complete an optimum design, using mathematical programming techniques, intelligent search methods and artificial intelligence (AI). Initial design and testing of a CATO prototype (CATO-1) has been completed recently. The objective was to prove the feasibility of combining AI techniques, simulation techniques, an optical device library and a graphical user interface into a flexible CAD tool for obtaining optimal communication network designs in terms of system cost and performance. CATO-1 is an experimental tool for designing packet-switching wavelength division multiplexing all-optical communication systems using a LAN/MAN ring topology as the underlying network. The two specific AI algorithms incorporated are simulated annealing and a genetic algorithm. CATO-1 finds the optimal number of transceivers for each network node, using an objective function that includes the cost of the devices and the overall system performance.

  10. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. Large scale deep learning for computer aided detection of mammographic lesions.

    Science.gov (United States)

    Kooi, Thijs; Litjens, Geert; van Ginneken, Bram; Gubern-Mérida, Albert; Sánchez, Clara I; Mann, Ritse; den Heeten, Ard; Karssemeijer, Nico

    2017-01-01

    Recent advances in machine learning yielded new techniques to train deep neural networks, which resulted in highly successful applications in many pattern recognition tasks such as object detection and speech recognition. In this paper we provide a head-to-head comparison between a state-of-the art in mammography CAD system, relying on a manually designed feature set and a Convolutional Neural Network (CNN), aiming for a system that can ultimately read mammograms independently. Both systems are trained on a large data set of around 45,000 images and results show the CNN outperforms the traditional CAD system at low sensitivity and performs comparable at high sensitivity. We subsequently investigate to what extent features such as location and patient information and commonly used manual features can still complement the network and see improvements at high specificity over the CNN especially with location and context features, which contain information not available to the CNN. Additionally, a reader study was performed, where the network was compared to certified screening radiologists on a patch level and we found no significant difference between the network and the readers. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A CAD (Classroom Assessment Design) of a Computer Programming Course

    Science.gov (United States)

    Hawi, Nazir S.

    2012-01-01

    This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified…

  13. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement.

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin; Tulga, Ayça

    2017-12-01

    To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) ( P CAD/CAM restorative materials was modified after treatments. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

  14. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  15. Correlation between mammographic findings and corresponding histopathology. Potential predictors for biological characteristics of breast diseases

    International Nuclear Information System (INIS)

    Tamaki, Kentaro; Ishida, Takanori; Miyashita, Minoru; Amari, Masakazu; Ohuchi, Noriaki; Tamaki, Nobumitsu; Sasano, Hironobu

    2011-01-01

    The present study retrospectively evaluated the mammographic findings of 606 Japanese women with breast cancer (median age 50 years; range 27-89 years) and correlated them with histopathological characteristics. Mammographic findings were evaluated with an emphasis on mass shape, margin, density, calcification, and the presence of architectural distortion; these findings were correlated with histopathological characteristics such as intrinsic subtype, histological grade, lymphovascular invasion, and the Ki-67 labeling index. An irregular mass shape and masses with a spiculated margin were significantly higher in the group of patients with luminal A breast cancer than in patients with masses that were lobular or round, or in tumors with an indistinct or microlobulated periphery (P=0.017, P=0.024, P<0.001, and P=0.001, respectively). Irregular mass shape and spiculated periphery were significantly lower in patients with Grade 3 cancer (P<0.001 for both). In terms of lymphovascular invasion, there were significant differences between oval and irregular or round mass shape (P=0.008 and P=0.034), between tumors with a microlobulated and indistinct periphery (P=0.014), between tumors with a punctate and amorphous or pleomorphic calcification shape (P=0.030 and 0.038), and between the presence and absence of architectural distortion (P=0.027). Equivalent or low-density masses were also higher in Grade 1 breast cancers (P=0.007). There were significant differences in the Ki-67 labeling index between irregular and lobular or round tumors (P<0.001 and P=0.014), as well as between spiculated and indistinct or microlobulated tumors (P<0.001 for both). Significant differences were noted in the mammographic features of different primary breast cancer subtypes. These proposed mammographic diagnostic criteria based on biological characteristics may contribute to a more accurate prediction of biological behavior of breast malignancies. (author)

  16. Development of integrated CAD system PV-1

    International Nuclear Information System (INIS)

    Miyamoto, Hitoshi; Ogawa, Kazuya; Shibata, Masayoshi.

    1997-01-01

    An integrated CAD system for pressure vessels, such as heat exchangers, drums, towers, jacketed vessels, and tanks, has been developed. The system is operated by MS-DOS personal computers combined in a LAN. Pressure vessel designers can work watching using the computer display because the system automatically manages design work, on a common data base. The project team members in other sections, such as production, cost control, and design, have the same data concurrently. Personal computers unite the 3D CAD system, and the generated design with detail dimensions and shapes is stored in the 3D CAD system automatically. The system has promoted higher design quality and greatly reduced design cost. (author)

  17. Fibrocystic disease of breast: variable mammographic and sonography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye [Chung Ang Gil Hospital, Incheon (Korea, Republic of)

    1993-12-15

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, the echogenicity was variable; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical

  18. Fibrocystic disease of breast: variable mammographic and sonography appearance

    International Nuclear Information System (INIS)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye

    1993-01-01

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, theechogenicity was variable ; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical

  19. MEBT design for C-ADS

    International Nuclear Information System (INIS)

    Geng Huiping; Tang Jingyu; Li Zhihui; Yan Fang; Ouyang Huafu

    2012-01-01

    In proton accelerators, the Medium Energy Beam Transport (MEBT) line is an essential part for transporting and matching the beam from the RFQ to the next type of accelerating structure. The MEBT is also very important in machine commissioning and tuning. The design of the China Accelerator Driven System is making great progress. The C-ADS project is composed of two independent injectors; therefore, two MEBT lines will be designed independently. In this paper, we will give a detailed description of the MEBT design (including parameter selection and beam dynamics calculation) for the injector I of the C-ADS project. (authors)

  20. Engineering drawing from first principles using AutoCAD

    CERN Document Server

    Maguire, Dennis E

    1998-01-01

    Engineering Drawing From First Principles is a guide to good draughting for students of engineering who need to learn how to produce technically accurate and detailed designs to British and International Standards. Written by Dennis Maguire, an experienced author and City and Guilds chief examiner, this text is designed for use on Further Education and University courses where a basic understanding of draughtsmanship and CAD is necessary. Although not written as an AutoCAD tutor, the book will be a useful introduction to good CAD practice.Part of the Revision and Self-Assessmen

  1. Remote Patient Management in a Mammographic Screening Environment in Underserved Areas

    Science.gov (United States)

    2005-09-01

    of 4,945 paired examinations. Radiology 2001; 218:873-880. 10. Malich A, Marx C, Facius M, Boehm T, Fleck M, Kaiser WA. Tumour 24. Venta LA, Hendrick...218:873-880. KF, Sickles EA. Mammographic character- factor determining the quality of com- 15. Venta LA, Hendrick RE, Adler YT, et al. iSicks of 115

  2. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  3. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. CAD-based Monte Carlo automatic modeling method based on primitive solid

    International Nuclear Information System (INIS)

    Wang, Dong; Song, Jing; Yu, Shengpeng; Long, Pengcheng; Wang, Yongliang

    2016-01-01

    Highlights: • We develop a method which bi-convert between CAD model and primitive solid. • This method was improved from convert method between CAD model and half space. • This method was test by ITER model and validated the correctness and efficiency. • This method was integrated in SuperMC which could model for SuperMC and Geant4. - Abstract: Monte Carlo method has been widely used in nuclear design and analysis, where geometries are described with primitive solids. However, it is time consuming and error prone to describe a primitive solid geometry, especially for a complicated model. To reuse the abundant existed CAD models and conveniently model with CAD modeling tools, an automatic modeling method for accurate prompt modeling between CAD model and primitive solid is needed. An automatic modeling method for Monte Carlo geometry described by primitive solid was developed which could bi-convert between CAD model and Monte Carlo geometry represented by primitive solids. While converting from CAD model to primitive solid model, the CAD model was decomposed into several convex solid sets, and then corresponding primitive solids were generated and exported. While converting from primitive solid model to the CAD model, the basic primitive solids were created and related operation was done. This method was integrated in the SuperMC and was benchmarked with ITER benchmark model. The correctness and efficiency of this method were demonstrated.

  5. Mammographic density and histopathologic characteristics of screen-detected tumors in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Moshina, Nataliia; Ursin, Giske; Hoff, Solveig Roth; Akslen, Lars A; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2015-01-01

    High mammographic density might mask breast tumors, resulting in delayed diagnosis or missed cancers. To investigate the association between mammographic density and histopathologic tumor characteristics (histologic type, size, grade, and lymph node status) among women screened in the Norwegian Breast Cancer Screening Program. Information about 1760 screen-detected ductal carcinoma in situ (DCIS) and 7366 invasive breast cancers diagnosed among women aged 50–69 years, 1996–2010, was analyzed. The screening mammograms were classified subjectively according to the amount of fibroglandular tissue into fatty, medium dense, and dense by breast radiologists. Chi-square test was used to compare the distribution of tumor characteristics by mammographic density. Odds ratio (OR) of tumor characteristics by density was estimated by means of logistic regression, adjusting for screening mode (screen-film and full-field digital mammography), and age. Mean and median tumor size of invasive breast cancers was 13.8 and 12 mm, respectively, for women with fatty breasts, and 16.2 and 14 mm for those with dense breasts. Lymph node positive tumors were identified among 20.6% of women with fatty breasts compared with 27.2% of those with dense breasts (P < 0.001). The proportion of DCIS was significantly lower for women with fatty (15.8%) compared with dense breasts (22.0%). Women with dense breasts had an increased risk of large (OR, 1.44; 95% CI, 1.18–1.73) and lymph node positive tumors (OR, 1.26; 95% CI, 1.05–1.51) compared with women with fatty and medium dense breasts. High mammographic density was positively associated with tumor size and lymph node positive tumors

  6. Genome-wide association study identifies multiple loci associated with both mammographic density and breast cancer risk

    Science.gov (United States)

    Lindström, Sara; Thompson, Deborah J.; Paterson, Andrew D.; Li, Jingmei; Gierach, Gretchen L.; Scott, Christopher; Stone, Jennifer; Douglas, Julie A.; dos-Santos-Silva, Isabel; Fernandez-Navarro, Pablo; Verghase, Jajini; Smith, Paula; Brown, Judith; Luben, Robert; Wareham, Nicholas J.; Loos, Ruth J.F.; Heit, John A.; Pankratz, V. Shane; Norman, Aaron; Goode, Ellen L.; Cunningham, Julie M.; deAndrade, Mariza; Vierkant, Robert A.; Czene, Kamila; Fasching, Peter A.; Baglietto, Laura; Southey, Melissa C.; Giles, Graham G.; Shah, Kaanan P.; Chan, Heang-Ping; Helvie, Mark A.; Beck, Andrew H.; Knoblauch, Nicholas W.; Hazra, Aditi; Hunter, David J.; Kraft, Peter; Pollan, Marina; Figueroa, Jonine D.; Couch, Fergus J.; Hopper, John L.; Hall, Per; Easton, Douglas F.; Boyd, Norman F.; Vachon, Celine M.; Tamimi, Rulla M.

    2015-01-01

    Mammographic density reflects the amount of stromal and epithelial tissues in relation to adipose tissue in the breast and is a strong risk factor for breast cancer. Here we report the results from meta-analysis of genome-wide association studies (GWAS) of three mammographic density phenotypes: dense area, non-dense area and percent density in up to 7,916 women in stage 1 and an additional 10,379 women in stage 2. We identify genome-wide significant (P<5×10−8) loci for dense area (AREG, ESR1, ZNF365, LSP1/TNNT3, IGF1, TMEM184B, SGSM3/MKL1), non-dense area (8p11.23) and percent density (PRDM6, 8p11.23, TMEM184B). Four of these regions are known breast cancer susceptibility loci, and four additional regions were found to be associated with breast cancer (P<0.05) in a large meta-analysis. These results provide further evidence of a shared genetic basis between mammographic density and breast cancer and illustrate the power of studying intermediate quantitative phenotypes to identify putative disease susceptibility loci. PMID:25342443

  7. Image quality and dose in mammographic images obtained in Mexico City hospitals

    International Nuclear Information System (INIS)

    Ruiz-Trejo, C.; Brandan, M.-E.; Verdejo, M.; Flores, A.; Guevara, M.; Martin, J.; Madero-Preciado, L.

    2001-01-01

    The performance of three mammographic systems in large Mexican hospitals has been evaluated, as well as the image quality and associated dose. Quality control tests include examination of X-ray equipment, darkroom conditions, film processor, and viewboxes. Systems referred to as '1', '2', and '3' passed 50%, 75% and 75% of these tests, respectively. Quality image is assessed using five images obtained under similar nominal conditions in each X-ray equipment. System 1 generates no image of acceptable quality, while equipment 2 and 3 produce one and two, respectively. The mean glandular dose for the best images obtained in each service with an accreditation phantom has been measured, and the values are 1.4 mGy, 1.6 mGy, and 1.0 mGy, respectively. (author)

  8. The CAD concept for stellarator-type magnetic systems

    International Nuclear Information System (INIS)

    Vorobyova, V.P.; Martynov, S.A.; Khazhmuradov, M.A.

    2002-01-01

    The paper describes the computer-aided design (CAD) concept for stellarator-type magnetic systems. Consideration is given to the main peculiarities, principles, and dialog organization and design stages of the CAD. The practical realization of the concept is illustrated by specific examples

  9. Comparison of Mammographic Changes Across Three Different Fractionation Schedules for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Sibo [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Paster, Lina F. [Department of Radiology, Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Kim, Sinae [Biometrics Division, Rutgers Cancer Institute of New Jersey, and Department of Biostatistics, Rutgers School of Public Health, Rutgers, New Jersey (United States); Kirstein, Laurie [Division of Surgical Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Haffty, Bruce G.; Ferro, Adam [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Amorosa, Judith [Department of Radiology, Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Goyal, Sharad, E-mail: goyalsh@rutgers.edu [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States)

    2016-06-01

    Purpose: As the use of hypofractionated breast radiation therapy (RT) increases, so will the need for long-term data on post-RT mammographic changes. The purpose of the present study was to longitudinally compare the incidence of common mammographic sequelae seen after breast conserving surgery and RT in patients treated with accelerated partial breast irradiation (APBI), hypofractionated whole breast irradiation (HWBI), and conventionally fractionated whole breast irradiation (WBI). Methods and Materials: Patients treated with either APBI or HWBI after breast conserving therapy and with ≥3 mammograms of the treated breast were identified. They were matched 1:1 by age ±5 years to patients treated with WBI. The mammograms were evaluated for common post-RT breast findings by a mammographer who was unaware of the treatment. The outcomes were analyzed using a cumulative logistic regression model; P<.05 indicated statistically significance. Results: Of 89 patients treated with RT from 2006 to 2011, 29 had received APBI, 30 had received HWBI, and 30 had received WBI. Their median age was 60 years (range 33-83). A total of 605 mammograms were evaluated, with a median follow-up of 48 months. The treatment technique did not affect the severity of architectural distortion when the groups were evaluated longitudinally. The likelihood of finding skin thickening decreased with increasing follow-up duration (odds ratio 0.6; P<.001) adjusted for fractionation schemes. No differences were seen with respect to changes in skin thickening, fluid collections, or calcifications among the treatment groups, after adjustment for the follow-up time. The clinical characteristics, including age, race, T stage, and chemotherapy use, were not linked to the likelihood of finding several mammographic phenomena over time. Conclusions: Although specific post-treatment imaging findings evolved over time, RT fractionation did not alter the relative incidence or severity of architectural

  10. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    Science.gov (United States)

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  11. Association between mammographic density and pregnancies relative to age and BMI: a breast cancer case-only analysis.

    Science.gov (United States)

    Hack, Carolin C; Emons, Julius; Jud, Sebastian M; Heusinger, Katharina; Adler, Werner; Gass, Paul; Haeberle, Lothar; Heindl, Felix; Hein, Alexander; Schulz-Wendtland, Rüdiger; Uder, Michael; Hartmann, Arndt; Beckmann, Matthias W; Fasching, Peter A; Pöhls, Uwe G

    2017-12-01

    Percentage mammographic density (PMD) is a major risk factor for breast cancer (BC). It is strongly associated with body mass index (BMI) and age, which are themselves risk factors for breast cancer. This analysis investigated the association between the number of full-term pregnancies and PMD in different subgroups relative to age and BMI. Patients were identified in the breast cancer database of the University Breast Center for Franconia. A total of 2410 patients were identified, for whom information on parity, age, and BMI, and a mammogram from the time of first diagnosis were available for assessing PMD. Linear regression analyses were conducted to investigate the influence on PMD of the number of full-term pregnancies (FTPs), age, BMI, and interaction terms between them. As in previous studies, age, number of FTPs, and BMI were found to be associated with PMD in the expected direction. However, including the respective interaction terms improved the prediction of PMD even further. Specifically, the association between PMD and the number of FTPs differed in young patients under the age of 45 (mean decrease of 0.37 PMD units per pregnancy) from the association in older age groups (mean decrease between 2.29 and 2.39 PMD units). BMI did not alter the association between PMD and the number of FTPs. The effect of pregnancies on mammographic density does not appear to become apparent before the age of menopause. The mechanism that drives the effect of pregnancies on mammographic density appears to be counter-regulated by other influences on mammographic density in younger patients.

  12. The application of CAD / CAM technology in Dentistry

    Science.gov (United States)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  13. 3D CAD ON Qinshan CANDU project

    International Nuclear Information System (INIS)

    Goland, D.

    2000-01-01

    This paper briefly describe AECL's work in applying computer-aided engineering tools to the Qinshan CANDU project. The main thrust of this paper is to introduce the major CAD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CAD tools and their applications are also briefly introduced. (author)

  14. Comparison of Marginal and Internal Adaptation of Heat-Pressed and CAD/CAM Porcelain Laminate Veneers and a 2-Year Follow-Up.

    Science.gov (United States)

    Yuce, Mert; Ulusoy, Mubin; Turk, Ayse Gozde

    2017-12-22

    To compare marginal and internal adaptations of porcelain laminate veneers fabricated with heat-pressed and CAD/CAM techniques, and to evaluate the clinical performances 2 years after cementation. Thirty heat-pressed and 31 CAD/CAM porcelain laminate veneers were fabricated for 12 patients. Silicone replicas of each veneer were obtained. Replicas were sectioned into 4 parts to measure adaptations of the veneers. A stereomicroscope was used to measure from 3 locations of replicas for marginal, and 9 locations for internal adaptations at 40x magnification. Clinical evaluations were done at baseline and 6, 12, 18, and 24 months after cementation according to the modified United States Public Health Service (USPHS) criteria. Independent samples t-test compared the adaptation values between heat-pressed and CAD/CAM groups. Paired t-test was used to evaluate marginal and internal adaptations of each group. Differences between the modified USPHS criteria ratings of heat-pressed and CAD/CAM groups were determined by the Mann-Whitney U test. Kaplan-Meier analysis was used to analyze the survival ratings of the veneers (p CAD/CAM veneers were 295 and 314.98 μm, respectively, and there was no statistically significant difference (p = 0.541). Internal adaptation values of groups were not statistically different either (201.82 μm for heat pressed; 195.47 μm for CAD/CAM p = 0.734). When marginal and internal adaptation values were compared within groups, there were significant differences both for heat-pressed (p CAD/CAM (p CAD/CAM or heat-pressed, had no effect on the marginal and internal adaptation of porcelain laminate veneers. The results showed that both fabrication techniques performed well after 2 years of clinical performance. © 2017 by the American College of Prosthodontists.

  15. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  16. TNF-alpha-308G>A polymorphism and the risk of familial CAD in a Pakistani population.

    Science.gov (United States)

    Hussain, Sabir; Iqbal, Tahir; Javed, Qamar

    2015-01-01

    A case-control and trio-families study was performed to establish a potential association between TNF-alpha gene promoter SNPs at -308 and -238, and occurrence of CAD in a Pakistani population. In the first phase, 150 patients and 150 controls were enrolled in the case-control association study. In the second phase, heritability of susceptible alleles was investigated from 88 trio-families with CAD affected offspring. Biochemical analysis of lipids and hs-CRP was carried out spectrophotometrically, while serum TNF-alpha concentrations were determined by enzyme-linked immunosorbent assay. Genotyping of the TNF-alpha SNPs were determined by PCR-RFLP method. Elevated serum TNF-alpha and hs-CRP were observed from CAD vs. controls (PA polymorphism in case-control study revealed that the said SNP was significantly associated with the increased risk of CAD. The findings demonstrated a significant link between the TNF-alpha variant allele A at -308 and CAD (P=0.0035), whereas the -238 SNP was not associated with the disease. Haplotype A-G of the TNF-alpha gene at -308G>A and -238G>A showed higher frequency in the patient group compared with controls (PA polymorphism is associated with CAD in the study population. Furthermore, for the first time, we showed that the TNF-alpha-308A allele was significantly associated with the familial CAD in our high risk population. Copyright © 2014. Published by Elsevier Inc.

  17. KiCad challenges the big ones

    CERN Document Server

    Antonella Del Rosso

    2015-01-01

    Printed Circuit Boards (PCB) are the heart of any electronic device, including your toaster and your smartphone. Designing PCBs is the job of electronic engineers who, so far, have often had no option but to use proprietary tools to design complex circuits. Thanks to the efforts that CERN experts have put in to improve the free KiCad software, that situation is about to change.   KiCad's development started in 1992 as a way to design PCBs, the units that control how an electronic device works. Since 2013, experts in the Beams department have made important contributions to KiCad as part of the Open Hardware Initiative (OHI), which provides a framework to facilitate knowledge exchange across the electronic design community. “Our vision is to allow the hardware developers to share as easily as their software colleagues,” says Javier Serrano, head of the BE-CO-HT section and OHI initiator. “Software sources are easily shared online because they are text ...

  18. CADx of mammographic masses and clustered microcalcifications: A review

    International Nuclear Information System (INIS)

    Elter, Matthias; Horsch, Alexander

    2009-01-01

    Breast cancer is the most common type of cancer among women in the western world. While mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, the interpretation of mammograms is a difficult and error-prone task. Hence, computer aids have been developed that assist the radiologist in the interpretation of mammograms. Computer-aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer-aided diagnosis (CADx) systems have been proposed that assist the radiologist in the classification of mammographic lesions as benign or malignant. While a broad variety of approaches to both CADe and CADx systems have been published in the past two decades, an extensive survey of the state of the art is only available for CADe approaches. Therefore, a comprehensive review of the state of the art of CADx approaches is presented in this work. Besides providing a summary, the goals for this article are to identify relations, contradictions, and gaps in literature, and to suggest directions for future research. Because of the vast amount of publications on the topic, this survey is restricted to the two most important types of mammographic lesions: masses and clustered microcalcifications. Furthermore, it focuses on articles published in international journals.

  19. CADx of mammographic masses and clustered microcalcifications: A review

    Energy Technology Data Exchange (ETDEWEB)

    Elter, Matthias; Horsch, Alexander [Fraunhofer Institute for Integrated Circuits (IIS), Am Wolfsmantel 33, 91058 Erlangen (Germany); Institute for Medical Statistics and Epidemiology, TU Muenchen, Ismaninger Strasse 22, 81675 Muenchen (Germany) and Department of Computer Science, University of Tromsoe Breivika, N-9037 Tromsoe (Norway)

    2009-06-15

    Breast cancer is the most common type of cancer among women in the western world. While mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, the interpretation of mammograms is a difficult and error-prone task. Hence, computer aids have been developed that assist the radiologist in the interpretation of mammograms. Computer-aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer-aided diagnosis (CADx) systems have been proposed that assist the radiologist in the classification of mammographic lesions as benign or malignant. While a broad variety of approaches to both CADe and CADx systems have been published in the past two decades, an extensive survey of the state of the art is only available for CADe approaches. Therefore, a comprehensive review of the state of the art of CADx approaches is presented in this work. Besides providing a summary, the goals for this article are to identify relations, contradictions, and gaps in literature, and to suggest directions for future research. Because of the vast amount of publications on the topic, this survey is restricted to the two most important types of mammographic lesions: masses and clustered microcalcifications. Furthermore, it focuses on articles published in international journals.

  20. Risk stratification of women with false-positive test results in mammography screening based on mammographic morphology and density

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Lynge, Elsebeth

    2017-01-01

    a case-control study nested in the population-based screening programme in Copenhagen, Denmark. We included 288 cases and 288 controls based on a cohort of 4743 women with at least one FP-test result in 1991–2005 who were followed up until 17 April 2008. Film-based mammograms were assessed using...... the Breast Imaging-Reporting and Data System (BI-RADS) density classification, the Tabár classification, and two automated techniques quantifying percentage mammographic density (PMD) and mammographic texture (MTR), respectively. The association with breast cancer was estimated using binary logistic...

  1. APPLICATION OF 3D DIGITAL SCANNING AND CAD/CAM SYSTEMS FOR ZIRCONIA INDIRECT RESTORATIONS

    Directory of Open Access Journals (Sweden)

    Mariela Tsanova

    2016-09-01

    Full Text Available Object: To study the CAD/CAM systems’ possibilities for manufacturing Zirconia indirect restorations for restoring vital, vastly devastated teeth. Material and methods: Five patients with vital, heavily destroyed molars were included in the clinical study. The teeth were prepared according to requirements for Zirconia restorations. The impressions were taken with 3D intraoral scanner. The acquired data is transmitted electronically for designing the future restoration by the CAD software. After designing, the restoration is milled by the CAM module and sintered, according to a specially projected programme in accordance with the manufacturing demands. After clinical check-up, the restorations are glazed, air-blasted and cemented. Results: Setting up an individual protocol for working with CAD/CAM systems for restoring vital, severely devastated teeth with Zirconia indirect restorations. A research is made on 3D digital scanning, occlusal and proximal modeling, virtual articulation, analyzing the incline of the cavity walls, the thickness of the restoration and the possibilities for restoring the anatomy of the tooth according to patient’s individual characteristics of the teeth’s arch. Conclusion: The scanning and design process should be evaluated with the same quality control as when using traditional methods. The CAD software requires excellent preparation of the tooth cavity and digital scanning. This is the reason why these systems require a thorough understanding of CAD/CAM calibration and parameters of the product to be clinically acceptable. Once understood, CAD/CAM dentistry can create detailed and accurate restorations that function and perform with great success and longevity.

  2. User productivity as a function of AutoCAD interface design.

    Science.gov (United States)

    Mitta, D A; Flores, P L

    1995-12-01

    Increased operator productivity is a desired outcome of user-CAD interaction scenarios. Two objectives of this research were to (1) define a measure of operator productivity and (2) empirically investigate the potential effects of CAD interface design on operator productivity, where productivity is defined as the percentage of a drawing session correctly completed per unit time. Here, AutoCAD provides the CAD environment of interest. Productivity with respect to two AutoCAD interface designs (menu, template) and three task types (draw, dimension, display) was investigated. Analysis of user productivity data revealed significantly higher productivity under the menu interface condition than under the template interface condition. A significant effect of task type was also discovered, where user productivity under display tasks was higher than productivity under the draw and dimension tasks. Implications of these results are presented.

  3. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    Science.gov (United States)

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  4. Trend and application of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-09-01

    This report is about trend and application of CAD/CAM system, giving descriptions of computer aided design which helps construction, engineering and drafting tasks. It also tells of computer aided manufacturing related general design of manufactures, which includes process design, production management, decision of work technology, processing. The need and application of CAD/CAM system is increasing more and more for industry each area.

  5. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    Science.gov (United States)

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial

  6. Integrated CAD/CAE for nuclear power plants

    International Nuclear Information System (INIS)

    Lecoq, P.; Lachat, J.C.

    1987-01-01

    The size of the French nuclear power program has led both EDF and Framatome to equip themselves progressively with management software, computer-assisted design (CAD) systems, and computer-assisted engineering (CAE) systems. The nature of the projects and of the respective activities of EDF and Framatome determined the essential specifications of these computerized systems. EDF and Framatome have pooled their CAD/CAE efforts in a joint venture (Groupement d'Interet Economique) called GIAO, set up in 1985 by EDF and Aquitaine Systeme (a subsidiary of Framatome and Elf Aquitaine). GIAO's ambition is to become a pole of French CAD/CAE efforts and to foster progress in integrated computer-assisted engineering, by enlarging the synergy of EDF and Framatome in this field to other enterprises that participate in design and construction of complex industrial plants

  7. Laboratory Performance of Universal Adhesive Systems for Luting CAD/CAM Restorative Materials.

    Science.gov (United States)

    Siqueira, Fabiana; Cardenas, Andres Millan; Gutierrez, Mario Felipe; Malaquias, Pâmela; Hass, Viviane; Reis, Alessandra; Loguercio, Alessandro D; Perdigão, Jorge

    To evaluate the microshear bond strength (μSBS) of several universal adhesive systems applied on five different indirect restorative materials. Five CAD/CAM materials were selected: 1) indirect resin composite (LAV); 2) feldspathic glass ceramic (VTR); 3) leucite-reinforced glass-ceramic (EMP); 4) lithium disilicate ceramic (EMX); 5) yttrium-stabilized zirconium dioxide (CZI). For each material, 15 blocks were cut into 4 rectangular sections (6 × 6 × 6 mm) (n = 60 per group), and processed as recommended by the respective manufacturer. For each indirect material, the following adhesive systems were applied according to the respective manufacturer's instructions: 1) AdheSE Universal [ADU]; 2) All-Bond Universal (ABU); 3) Ambar Universal (AMB); 4) Clearfil Universal (CFU); 5) Futurabond U (FBU); 6) One Coat 7 Universal (OCU); 7) Peak Universal Bond (PUB); 8) Prime&Bond Elect (PBE); 9) Scotchbond Universal Adhesive (SBU); 10) Xeno Select (XEN, negative control). After the application of the adhesive system, cylinder-shaped transparent matrices were filled with a dual-curing resin cement (NX3) and light cured. Specimens were stored in water (37°C for 24 h) and tested in shear mode at 1.0 mm/min (mSBS). The failure pattern and μSBS were statistically evaluated (a = 0.05). LAV, VTR, and EMP showed a greater number of cohesive fractures than EMX and CZI (p materials. There was a wide variability in mean μSBS when different universal adhesives were applied to the several CAD/CAM indirect materials. Most universal adhesives bonded well to air-abraded zirconia.

  8. International Consortium on Mammographic Density : Methodology and population diversity captured across 22 countries

    NARCIS (Netherlands)

    McCormack, Valerie A; Burton, Anya; Dos-Santos-Silva, Isabel; Hipwell, John H; Dickens, Caroline; Salem, Dorria; Kamal, Rasha; Hartman, Mikael; Lee, Charmaine Pei Ling; Chia, Kee-Seng; Ozmen, Vahit; Aribal, Mustafa Erkin; Flugelman, Anath Arzee; Lajous, Martín; Lopez-Riduara, Ruy; Rice, Megan; Romieu, Isabelle; Ursin, Giske; Qureshi, Samera; Ma, Huiyan; Lee, Eunjung; van Gils, Carla H; Wanders, Johanna O P; Vinayak, Sudhir; Ndumia, Rose; Allen, Steve; Vinnicombe, Sarah; Moss, Sue; Won Lee, Jong; Kim, Jisun; Pereira, Ana; Garmendia, Maria Luisa; Sirous, Reza; Sirous, Mehri; Peplonska, Beata; Bukowska, Agnieszka; Tamimi, Rulla M; Bertrand, Kimberly; Nagata, Chisato; Kwong, Ava; Vachon, Celine; Scott, Christopher; Perez-Gomez, Beatriz; Pollan, Marina; Maskarinec, Gertraud; Giles, Graham; Hopper, John; Stone, Jennifer; Rajaram, Nadia; Teo, Soo-Hwang; Mariapun, Shivaani; Yaffe, Martin J; Schüz, Joachim; Chiarelli, Anna M; Linton, Linda; Boyd, Norman F

    2015-01-01

    Mammographic density (MD) is a quantitative trait, measurable in all women, and is among the strongest markers of breast cancer risk. The population-based epidemiology of MD has revealed genetic, lifestyle and societal/environmental determinants, but studies have largely been conducted in women with

  9. A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas

    Science.gov (United States)

    Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.

    2007-03-01

    Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.

  10. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.

    Science.gov (United States)

    Chiarelli, Anna M; Prummel, Maegan V; Muradali, Derek; Shumak, Rene S; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Done, Susan J; Yaffe, Martin J

    2015-11-01

    Most studies that have examined the effects of mammographic density and hormone therapy use on breast cancer detection have included screen-film mammography. This study further examines this association in post-menopausal women screened by digital mammography. Approved by the University of Toronto Research Ethics Board, this study identified 688,418 women of age 50-74 years screened with digital or screen-film mammography from 2008 to 2009 within the Ontario Breast Screening Program. Of 2993 eligible women with invasive breast cancer, 2450 were contacted and 1421 participated (847 screen-film mammography, 574 digital direct radiography). Mammographic density was measured by study radiologists using the standard BI-RADS classification system and by a computer-assisted method. Information on hormone therapy use was collected by a telephone-administered questionnaire. Logistic regression and two-tailed tests for significance evaluated associations between factors and detection method by mammography type. Women with >75 % radiologist-measured mammographic density compared to those with diagnosed with an interval than screen-detected cancer, with the difference being greater for those screened with screen-film (OR = 6.40, 95 % CI 2.30-17.85) than digital mammography (OR = 2.41, 95 % CI 0.67-8.58) and aged 50-64 years screened with screen-film mammography (OR = 10.86, 95 % CI 2.96-39.57). Recent former hormone therapy users were also at an increased risk of having an interval cancer with the association being significant for women screened with digital mammography (OR = 2.08, 95 % CI 1.17-3.71). Breast screening using digital mammography lowers the risk of having an interval cancer for post-menopausal women aged 50-64 with greater mammographic density.

  11. Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children

    Science.gov (United States)

    Zhang, Aifeng; Uyeda, Joshua; Tsao, Sinchai; Ma, Kevin; Vachon, Linda A.; Liu, Brent J.; Huang, H. K.

    2008-03-01

    Bone age assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on a left hand and wrist radiograph. The most commonly used standard: Greulich and Pyle (G&P) Hand Atlas was developed 50 years ago and exclusively based on Caucasian population. Moreover, inter- & intra-observer discrepancies using this method create a need of an objective and automatic BAA method. A digital hand atlas (DHA) has been collected with 1,400 hand images of normal children from Asian, African American, Caucasian and Hispanic descends. Based on DHA, a fully automatic, objective computer-aided-diagnosis (CAD) method was developed and it was adapted to specific population. To bring DHA and CAD method to the clinical environment as a useful tool in assisting radiologist to achieve higher accuracy in BAA, a web-based system with direct connection to a clinical site is designed as a novel clinical implementation approach for online and real time BAA. The core of the system, a CAD server receives the image from clinical site, processes it by the CAD method and finally, generates report. A web service publishes the results and radiologists at the clinical site can review it online within minutes. This prototype can be easily extended to multiple clinical sites and will provide the foundation for broader use of the CAD system for BAA.

  12. Computer-aided diagnosis of mammographic microcalcification clusters

    International Nuclear Information System (INIS)

    Kallergi, Maria

    2004-01-01

    Computer-aided diagnosis techniques in medical imaging are developed for the automated differentiation between benign and malignant lesions and go beyond computer-aided detection by providing cancer likelihood for a detected lesion given image and/or patient characteristics. The goal of this study was the development and evaluation of a computer-aided detection and diagnosis algorithm for mammographic calcification clusters. The emphasis was on the diagnostic component, although the algorithm included automated detection, segmentation, and classification steps based on wavelet filters and artificial neural networks. Classification features were selected primarily from descriptors of the morphology of the individual calcifications and the distribution of the cluster. Thirteen such descriptors were selected and, combined with patient's age, were given as inputs to the network. The features were ranked and evaluated for the classification of 100 high-resolution, digitized mammograms containing biopsy-proven, benign and malignant calcification clusters. The classification performance of the algorithm reached a 100% sensitivity for a specificity of 85% (receiver operating characteristic area index A z =0.98±0.01). Tests of the algorithm under various conditions showed that the selected features were robust morphological and distributional descriptors, relatively insensitive to segmentation and detection errors such as false positive signals. The algorithm could exceed the performance of a similar visual analysis system that was used as basis for development and, combined with a simple image standardization process, could be applied to images from different imaging systems and film digitizers with similar sensitivity and specificity rates

  13. The application of CAD, CAE & CAM in development of butterfly valve’s disc

    Science.gov (United States)

    Asiff Razif Shah Ranjit, Muhammad; Hanie Abdullah, Nazlin

    2017-06-01

    The improved design of a butterfly valve disc is based on the concept of sandwich theory. Butterfly valves are mostly used in various industries such as oil and gas plant. The primary failure modes for valves are indented disc, keyways and shaft failure and the cavitation damage. Emphasis on the application of CAD, a new model of the butterfly valve’s disc structure was designed. The structure analysis was analysed using the finite element analysis. Butterfly valve performance factors can be obtained is by using Computational Fluid Dynamics (CFD) software to simulate the physics of fluid flow in a piping system around a butterfly valve. A comparison analysis was done using the finite element to justify the performance of the structure. The second application of CAE is the computational fluid flow analysis. The upstream pressure and the downstream pressure was analysed to calculate the cavitation index and determine the performance throughout each opening position of the valve. The CAM process was done using 3D printer to produce a prototype and analysed the structure in form of prototype. The structure was downscale fabricated based on the model designed initially through the application of CAD. This study is utilized the application of CAD, CAE and CAM for a better improvement of the butterfly valve’s disc components.

  14. Digital mammographic tumor classification using transfer learning from deep convolutional neural networks.

    Science.gov (United States)

    Huynh, Benjamin Q; Li, Hui; Giger, Maryellen L

    2016-07-01

    Convolutional neural networks (CNNs) show potential for computer-aided diagnosis (CADx) by learning features directly from the image data instead of using analytically extracted features. However, CNNs are difficult to train from scratch for medical images due to small sample sizes and variations in tumor presentations. Instead, transfer learning can be used to extract tumor information from medical images via CNNs originally pretrained for nonmedical tasks, alleviating the need for large datasets. Our database includes 219 breast lesions (607 full-field digital mammographic images). We compared support vector machine classifiers based on the CNN-extracted image features and our prior computer-extracted tumor features in the task of distinguishing between benign and malignant breast lesions. Five-fold cross validation (by lesion) was conducted with the area under the receiver operating characteristic (ROC) curve as the performance metric. Results show that classifiers based on CNN-extracted features (with transfer learning) perform comparably to those using analytically extracted features [area under the ROC curve [Formula: see text

  15. Breast calcifications. A standardized mammographic reporting and data system to improve positive predictive value

    International Nuclear Information System (INIS)

    Perugini, G.; Bonzanini, B.; Valentino, C.

    1999-01-01

    The purpose of this work is to investigate the usefulness of a standardized reporting and data system in improving the positive predictive value of mammography in breast calcifications. Using the Breast Imaging Reporting and Data System lexicon developed by the American College of Radiology, it is defined 5 descriptive categories of breast calcifications and classified diagnostic suspicion of malignancy on a 3-grade scale (low, intermediate and high). Two radiologists reviewed 117 mammographic studies selected from those of the patients submitted to surgical biopsy for mammographically detected calcifications from January 1993 to December 1997, and classified them according to the above criteria. The positive predictive value was calculated for all examinations and for the stratified groups. Defining a standardized system for assessing and describing breast calcifications helps improve the diagnostic accuracy of mammography in clinical practice [it

  16. Regional trends in breast cancer incidence and mortality in Denmark prior to mammographic screening

    DEFF Research Database (Denmark)

    Andreasen, A H; Andersen, K W; Madsen, Mette

    1994-01-01

    To provide a basis for the evaluation of mammographic screening programmes in Denmark, a study was undertaken of the regional differences in breast cancer incidence and mortality. All 16 regions were followed for the 20 year period, 1970-89, before the start of the first population...... among women below age 60. The mortality was more stable, changing only from 24 to 28 (per 100,000 standardised WSP), but a significant increase occurred in the late 1980s. The study showed regional differences in both incidence and mortality of breast cancer in Denmark. Both the incidence......-based mammographic screening programme in the Copenhagen municipality in 1991. Multiplicative Poisson models were used for the analysis. In general, the incidence increased during this period from 55 to 70 [per 100,000 standardised world standard population (WSP)], and the analysis shows this to be most pronounced...

  17. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.

    Science.gov (United States)

    Duffy, Stephen W; Morrish, Oliver W E; Allgood, Prue C; Black, Richard; Gillan, Maureen G C; Willsher, Paula; Cooke, Julie; Duncan, Karen A; Michell, Michael J; Dobson, Hilary M; Maroni, Roberta; Lim, Yit Y; Purushothaman, Hema N; Suaris, Tamara; Astley, Susan M; Young, Kenneth C; Tucker, Lorraine; Gilbert, Fiona J

    2018-01-01

    Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm 3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Probability Density Functions for the CALIPSO Lidar Version 4 Cloud-Aerosol Discrimination (CAD) Algorithm

    Science.gov (United States)

    Liu, Z.; Kar, J.; Zeng, S.; Tackett, J. L.; Vaughan, M.; Trepte, C. R.; Omar, A. H.; Hu, Y.; Winker, D. M.

    2017-12-01

    typical optical and physical properties of feature subtypes, and thus provide a more comprehensive physical basis for discrimination. As a result of the changes made, the V4 CAD provides better performance and more reliable confidence levels. We describe the generation of V4 PDFs and present characterization and performance of the new CAD algorithm.

  19. Teach CAD and Measuring Skills through Reverse Engineering

    Science.gov (United States)

    Board, Keith

    2012-01-01

    This article describes a reverse engineering activity that gives students hands-on, minds-on experience with measuring tools, machine parts, and CAD. The author developed this activity to give students an abundance of practical experience with measuring tools. Equally important, it provides a good interface between the virtual world of CAD 3D…

  20. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  1. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  2. Image quality analysis of digital mammographic equipments

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, P.; Pascual, A.; Verdu, G. [Valencia Univ. Politecnica, Chemical and Nuclear Engineering Dept. (Spain); Rodenas, F. [Valencia Univ. Politecnica, Applied Mathematical Dept. (Spain); Campayo, J.M. [Valencia Univ. Hospital Clinico, Servicio de Radiofisica y Proteccion Radiologica (Spain); Villaescusa, J.I. [Hospital Clinico La Fe, Servicio de Proteccion Radiologica, Valencia (Spain)

    2006-07-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  3. Image quality analysis of digital mammographic equipments

    International Nuclear Information System (INIS)

    Mayo, P.; Pascual, A.; Verdu, G.; Rodenas, F.; Campayo, J.M.; Villaescusa, J.I.

    2006-01-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  4. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    Science.gov (United States)

    2011-01-01

    Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study

  5. Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.

    Science.gov (United States)

    Vikhe, P S; Thool, V R

    2016-04-01

    Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.

  6. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. A biomechanical model of mammographic compressions.

    Science.gov (United States)

    Chung, J H; Rajagopal, V; Nielsen, P M F; Nash, M P

    2008-02-01

    A number of biomechanical models have been proposed to improve nonrigid registration techniques for multimodal breast image alignment. A deformable breast model may also be useful for overcoming difficulties in interpreting 2D X-ray projections (mammograms) of 3D volumes (breast tissues). If a deformable model could accurately predict the shape changes that breasts undergo during mammography, then the model could serve to localize suspicious masses (visible in mammograms) in the unloaded state, or in any other deformed state required for further investigations (such as biopsy or other medical imaging modalities). In this paper, we present a validation study that was conducted in order to develop a biomechanical model based on the well-established theory of continuum mechanics (finite elasticity theory with contact mechanics) and demonstrate its use for this application. Experimental studies using gel phantoms were conducted to test the accuracy in predicting mammographic-like deformations. The material properties of the gel phantom were estimated using a nonlinear optimization process, which minimized the errors between the experimental and the model-predicted surface data by adjusting the parameter associated with the neo-Hookean constitutive relation. Two compressions (the equivalent of cranio-caudal and medio-lateral mammograms) were performed on the phantom, and the corresponding deformations were recorded using a MRI scanner. Finite element simulations were performed to mimic the experiments using the estimated material properties with appropriate boundary conditions. The simulation results matched the experimental recordings of the deformed phantom, with a sub-millimeter root-mean-square error for each compression state. Having now validated our finite element model of breast compression, the next stage is to apply the model to clinical images.

  8. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    International Nuclear Information System (INIS)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo; Pitocco, Dario; Di Stasio, Enrico; Trani, Carlo

    2016-01-01

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  9. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Radiological Sciences - Institute of Radiology, Rome (Italy); Pitocco, Dario [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Internal Medicine, Rome (Italy); Di Stasio, Enrico [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Clinical Biochemistry, Rome (Italy); Trani, Carlo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Cardiovascular Medicine - Institute of Cardiology, Rome (Italy)

    2016-03-15

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  10. Computerized analysis of mammographic parenchymal patterns for assessing breast cancer risk: Effect of ROI size and location

    International Nuclear Information System (INIS)

    Li Hui; Giger, Maryellen L.; Huo Zhimin; Olopade, Olufunmilayo I.; Lan Li; Weber, Barbara L.; Bonta, Ioana

    2004-01-01

    The long-term goal of our research is to develop computerized radiographic markers for assessing breast density and parenchymal patterns that may be used together with clinical measures for determining the risk of breast cancer and assessing the response to preventive treatment. In our earlier studies, we found that women at high risk tended to have dense breasts with mammographic patterns that were coarse and low in contrast. With our method, computerized texture analysis is performed on a region of interest (ROI) within the mammographic image. In our current study, we investigate the effect of ROI size and ROI location on the computerized texture features obtained from 90 subjects (30 BRCA1/BRCA2 gene-mutation carriers and 60 age-matched women deemed to be at low risk for breast cancer). Mammograms were digitized at 0.1 mm pixel size and various ROI sizes were extracted from different breast regions in the craniocaudal (CC) view. Seventeen features, which characterize the density and texture of the parenchymal patterns, were extracted from the ROIs on these digitized mammograms. Stepwise feature selection and linear discriminant analysis were applied to identify features that differentiate between the low-risk women and the BRCA1/BRCA2 gene-mutation carriers. ROC analysis was used to assess the performance of the features in the task of distinguishing between these two groups. Our results show that there was a statistically significant decrease in the performance of the computerized texture features, as the ROI location was varied from the central region behind the nipple. However, we failed to show a statistically significant decrease in the performance of the computerized texture features with decreasing ROI size for the range studied

  11. A multi-user selective undo/redo approach for collaborative CAD systems

    Directory of Open Access Journals (Sweden)

    Yuan Cheng

    2014-04-01

    Full Text Available The engineering design process is a creative process, and the designers must repeatedly apply Undo/Redo operations to modify CAD models to explore new solutions. Undo/Redo has become one of most important functions in interactive graphics and CAD systems. Undo/Redo in a collaborative CAD system is also very helpful for collaborative awareness among a group of cooperative designers to eliminate misunderstanding and to recover from design error. However, Undo/Redo in a collaborative CAD system is much more complicated. This is because a single erroneous operation is propagated to other remote sites, and operations are interleaved at different sites. This paper presents a multi-user selective Undo/Redo approach in full distributed collaborative CAD systems. We use site ID and State Vectors to locate the Undo/Redo target at each site. By analyzing the composition of the complex CAD model, a tree-like structure called Feature Combination Hierarchy is presented to describe the decomposition of a CAD model. Based on this structure, the dependency relationship among features is clarified. B-Rep re-evaluation is simplified with the assistance of the Feature Combination Hierarchy. It can be proven that the proposed Undo/Redo approach satisfies the intention preservation and consistency maintenance correctness criteria for collaborative systems.

  12. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    Science.gov (United States)

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...this time by allowing for rapid scanning, designing , development, and production of dental restorations. Using this technology gives dentists the

  13. Longevity of Single-Tooth All-Ceramic CAD/CAM Restorations: A Meta-Analysis

    Science.gov (United States)

    2013-07-01

    to the application of CAD/CAM technology in dentistry . The initial monetary investment for the equipment is significant. Systems currently on the...CURRENT DENTAL CAD/CAM SYSTEMS Current CAD/CAM systems in dentistry include: CEREC (CEramic REConstruction) and CEREC Acquisition Center (AC) with...of Adhesive Dentistry , 1 (3), 255- 265. 42     Bindl A, & Mörmann W. (2002). An up to 5-year clinical evaluation of posterior In- Ceram CAD

  14. Development of a sampling strategy and sample size calculation to estimate the distribution of mammographic breast density in Korean women.

    Science.gov (United States)

    Jun, Jae Kwan; Kim, Mi Jin; Choi, Kui Son; Suh, Mina; Jung, Kyu-Won

    2012-01-01

    Mammographic breast density is a known risk factor for breast cancer. To conduct a survey to estimate the distribution of mammographic breast density in Korean women, appropriate sampling strategies for representative and efficient sampling design were evaluated through simulation. Using the target population from the National Cancer Screening Programme (NCSP) for breast cancer in 2009, we verified the distribution estimate by repeating the simulation 1,000 times using stratified random sampling to investigate the distribution of breast density of 1,340,362 women. According to the simulation results, using a sampling design stratifying the nation into three groups (metropolitan, urban, and rural), with a total sample size of 4,000, we estimated the distribution of breast density in Korean women at a level of 0.01% tolerance. Based on the results of our study, a nationwide survey for estimating the distribution of mammographic breast density among Korean women can be conducted efficiently.

  15. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites.

    Science.gov (United States)

    Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik

    2015-03-01

    To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (pCAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (pCAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (pcurry>cress>distilled water) exerted the highest influence on DR (pCAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (pCAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Metabolite profiling reveals a role for atypical cinnamyl alcohol dehydrogenase CAD1 in the synthesis of coniferyl alcohol in tobacco xylem.

    Science.gov (United States)

    Damiani, Isabelle; Morreel, Kris; Danoun, Saïda; Goeminne, Geert; Yahiaoui, Nabila; Marque, Christiane; Kopka, Joachim; Messens, Eric; Goffner, Deborah; Boerjan, Wout; Boudet, Alain-Michel; Rochange, Soizic

    2005-11-01

    In angiosperms, lignin is built from two main monomers, coniferyl and sinapyl alcohol, which are incorporated respectively as G and S units in the polymer. The last step of their synthesis has so far been considered to be performed by a family of dimeric cinnamyl alcohol dehydrogenases (CAD2). However, previous studies on Eucalyptus gunnii xylem showed the presence of an additional, structurally unrelated, monomeric CAD form named CAD1. This form reduces coniferaldehyde to coniferyl alcohol, but is inactive on sinapaldehyde. In this paper, we report the functional characterization of CAD1 in tobacco (Nicotiana tabacum L.). Transgenic tobacco plants with reduced CAD1 expression were obtained through an RNAi strategy. These plants displayed normal growth and development, and detailed biochemical studies were needed to reveal a role for CAD1. Lignin analyses showed that CAD1 down-regulation does not affect Klason lignin content, and has a moderate impact on G unit content of the non-condensed lignin fraction. However, comparative metabolic profiling of the methanol-soluble phenolic fraction from basal xylem revealed significant differences between CAD1 down-regulated and wild-type plants. Eight compounds were less abundant in CAD1 down-regulated lines, five of which were identified as dimers or trimers of monolignols, each containing at least one moiety derived from coniferyl alcohol. In addition, 3-trans-caffeoyl quinic acid accumulated in the transgenic plants. Together, our results support a significant contribution of CAD1 to the synthesis of coniferyl alcohol in planta, along with the previously characterized CAD2 enzymes.

  17. The dynamic interaction of order flows and the CAD/USD exchange rate

    OpenAIRE

    Nikola Gradojevic; Christopher J. Neely

    2008-01-01

    We explore the relationship between disaggregated order flow, the Canada/U.S. dollar (CAD/USD) market and U.S. macroeconomic announcements. Three types of CAD order flow and the CAD/USD are cointegrated. Financial order flow appears to contemporaneously drive the CAD/USD while commercial order flow seems to contemporaneously respond to exchange rate movements. Past order flow and lagged exchange rates strongly explain most types of order flow. Despite this predictability and the contemporaneo...

  18. A comparison of five methods of measuring mammographic density: a case-control study.

    Science.gov (United States)

    Astley, Susan M; Harkness, Elaine F; Sergeant, Jamie C; Warwick, Jane; Stavrinos, Paula; Warren, Ruth; Wilson, Mary; Beetles, Ursula; Gadde, Soujanya; Lim, Yit; Jain, Anil; Bundred, Sara; Barr, Nicola; Reece, Valerie; Brentnall, Adam R; Cuzick, Jack; Howell, Tony; Evans, D Gareth

    2018-02-05

    High mammographic density is associated with both risk of cancers being missed at mammography, and increased risk of developing breast cancer. Stratification of breast cancer prevention and screening requires mammographic density measures predictive of cancer. This study compares five mammographic density measures to determine the association with subsequent diagnosis of breast cancer and the presence of breast cancer at screening. Women participating in the "Predicting Risk Of Cancer At Screening" (PROCAS) study, a study of cancer risk, completed questionnaires to provide personal information to enable computation of the Tyrer-Cuzick risk score. Mammographic density was assessed by visual analogue scale (VAS), thresholding (Cumulus) and fully-automated methods (Densitas, Quantra, Volpara) in contralateral breasts of 366 women with unilateral breast cancer (cases) detected at screening on entry to the study (Cumulus 311/366) and in 338 women with cancer detected subsequently. Three controls per case were matched using age, body mass index category, hormone replacement therapy use and menopausal status. Odds ratios (OR) between the highest and lowest quintile, based on the density distribution in controls, for each density measure were estimated by conditional logistic regression, adjusting for classic risk factors. The strongest predictor of screen-detected cancer at study entry was VAS, OR 4.37 (95% CI 2.72-7.03) in the highest vs lowest quintile of percent density after adjustment for classical risk factors. Volpara, Densitas and Cumulus gave ORs for the highest vs lowest quintile of 2.42 (95% CI 1.56-3.78), 2.17 (95% CI 1.41-3.33) and 2.12 (95% CI 1.30-3.45), respectively. Quantra was not significantly associated with breast cancer (OR 1.02, 95% CI 0.67-1.54). Similar results were found for subsequent cancers, with ORs of 4.48 (95% CI 2.79-7.18), 2.87 (95% CI 1.77-4.64) and 2.34 (95% CI 1.50-3.68) in highest vs lowest quintiles of VAS, Volpara and Densitas

  19. Optical properties of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E

    2014-09-01

    To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Cam Design Projects in an Advanced CAD Course for Mechanical Engineers

    Science.gov (United States)

    Ault, H. K.

    2009-01-01

    The objective of this paper is to present applications of solid modeling aimed at modeling of complex geometries such as splines and blended surfaces in advanced CAD courses. These projects, in CAD-based Mechanical Engineering courses, are focused on the use of the CAD system to solve design problems for applications in machine design, namely the…

  1. Building a web-based CAD server for clinical use, evaluation, and incremental learning. Implementation of analysis function based on execution result and clinical feedback

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Hayashi, Naoto; Masutani, Yoshitaka; Yoshikawa, Takeharu; Nemoto, Mitsutaka; Hanaoka, Shouhei; Maeda, Eriko; Ohtomo, Kuni; Miki, Soichiro

    2010-01-01

    Development of clinical image analysis software such as computer-assisted detection/diagnosis (CAD) involves a cycle of algorithm development, software implementation, clinical use, refinement of algorithm and software based on feedback. This cycle is expected to accelerate development of CAD software. We have been building a web-based CAD server that enables radiologists to use CAD software and to give feedback in clinical environment. The platform has been utilized in our hospital for 16 months, and more than 2,000 cases of feedback data have been accumulated. In this report, we introduce additional functions for performance evaluation based on executed results of CAD software and clinical feedback. (author)

  2. BombCAD - A new tool for bomb defense in nuclear facilities

    International Nuclear Information System (INIS)

    Massa, D.J.; Howard, J.W.; Sturm, S.R.

    1988-01-01

    This paper describes a new tool for analysis of the specific vulnerability of diverse facilites to bomb attack and for computer-aided-design (CAD) of siting, screening and hardening/softening aspects of comprehensive bomb defense programs. BombCAD combines the extensive architectural and engineering data base and graphics capabilities of modern architectural CAD systems with the bomb effects computational capability of the ''SECUREPLAN'' BOMB UTILITY. BombCAD permits architects/engineers, security professionals and facility managers to analytically estimate and graphically display facility vulnerability and changes (reductions) in vulnerability which result from the adoption of various bomb defense measures

  3. Association of rs662799 in APOA5 with CAD in Chinese Han population.

    Science.gov (United States)

    Chen, Hua; Ding, Shifang; Zhou, Mi; Wu, Xiayin; Liu, Xi; Wu, Yun; Liu, Dechao

    2018-01-08

    CAD (Coronary Artery Disease) is a complex disease that influenced by various environmental and genetic factors. Previous studies have found many single nucleotide polymorphisms (SNPs) associated with the risk of CAD occurrence. However, the results are inconsistent. In this study, we aim to investigate genetic etiology in Chinese Han population by analysis of 7 SNPs in lipid metabolism pathway that previously has been reported to be associated with CAD. A total of 631 samples were used in this study, including 435 CAD cases and 196 normal healthy controls. SNP genotyping were conducted via multiplex PCR amplifying followed by NGS (next-generation sequencing). Rs662799 in APOA5 (Apolipoprotein A5) gene was associated with CAD in Chinese Han population (Odds-ratio = 1.374, P-value = 0.03). No significant association was observed between the rest of SNPs and CAD. Stratified association analysis revealed rs5882 was associated with CAD in non-hypertension group (Odds-ratio = 1.593, P-value = 0.023). Rs1800588 was associated with CAD in smoking group (Odds-ratio = 1.603, P-value = 0.035). The minor allele of rs662799 was the risk factor of CAD occurrences in Chinese Han population.

  4. CAD-centric Computation Management System for a Virtual TBM. Final Report

    International Nuclear Information System (INIS)

    Munipalli, Ramakanth; Szema, K.Y.; Huang, P.Y.; Rowell, C.M.; Ying, A.; Abdou, M.

    2011-01-01

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  5. GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries

    Science.gov (United States)

    Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh

    2018-04-01

    Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.

  6. Integrating CAD modules in a PACS environment using a wide computing infrastructure.

    Science.gov (United States)

    Suárez-Cuenca, Jorge J; Tilve, Amara; López, Ricardo; Ferro, Gonzalo; Quiles, Javier; Souto, Miguel

    2017-04-01

    The aim of this paper is to describe a project designed to achieve a total integration of different CAD algorithms into the PACS environment by using a wide computing infrastructure. The aim is to build a system for the entire region of Galicia, Spain, to make CAD accessible to multiple hospitals by employing different PACSs and clinical workstations. The new CAD model seeks to connect different devices (CAD systems, acquisition modalities, workstations and PACS) by means of networking based on a platform that will offer different CAD services. This paper describes some aspects related to the health services of the region where the project was developed, CAD algorithms that were either employed or selected for inclusion in the project, and several technical aspects and results. We have built a standard-based platform with which users can request a CAD service and receive the results in their local PACS. The process runs through a web interface that allows sending data to the different CAD services. A DICOM SR object is received with the results of the algorithms stored inside the original study in the proper folder with the original images. As a result, a homogeneous service to the different hospitals of the region will be offered. End users will benefit from a homogeneous workflow and a standardised integration model to request and obtain results from CAD systems in any modality, not dependant on commercial integration models. This new solution will foster the deployment of these technologies in the entire region of Galicia.

  7. Survey on the use of CAD-CAM technology by UK and Irish dental technicians.

    Science.gov (United States)

    Blackwell, E; Nesbit, M; Petridis, H

    2017-05-12

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dental technicians' use and reporting of this technology.Purpose The aim of this cross sectional survey was to identify the extent digital technology has infiltrated the workplace and to investigate the factors affecting the use of CAD-CAM technology by dental laboratory technicians within Ireland and the UK.Materials and methods A web-based questionnaire was composed (Opinio, Object Planet Inc. Oslo, Norway) and distributed to UK and Irish dental technicians. Answers to all questions were anonymous and grouped such that general information was gathered initially, followed by branching of the survey into two sections depending on whether or not the respondent worked with CAD-CAM technology. Results were compiled and statistical analysis (Fisher's Exact test, SPSS, IBM, Armonk, New York, USA) was performed in order to investigate any correlation between various demographic variables and the answers provided.Results The survey was distributed to 760 UK technicians and 77 Irish technicians. The total number of completed surveys was 105, which yielded a total response rate of 14%. Most technicians reported using some form of CAD/CAM aspect in the workflow, and this was more significant for technicians working in large laboratories. Most training received was company-led. Large laboratories were also significantly correlated with less outsourcing of CAD/CAM work and a change in dental material use leading to the increase of zirconia and the decrease of noble alloys. Dental technicians did not report any significant change in working relationships and staffing as a result of CAD/CAM incorporation. High initial investment cost was the most common reason quoted from non-users, along with the lack of such technology in their working environment.

  8. Genotypes and haplotypes in the insulin-like growth factors, their receptors and binding proteins in relation to plasma metabolic levels and mammographic density

    Directory of Open Access Journals (Sweden)

    Chanock Stephen J

    2010-03-01

    Full Text Available Abstract Background Increased mammographic density is one of the strongest independent risk factors for breast cancer. It is believed that one third of breast cancers are derived from breasts with more than 50% density. Mammographic density is affected by age, BMI, parity, and genetic predisposition. It is also greatly influenced by hormonal and growth factor changes in a woman's life cycle, spanning from puberty through adult to menopause. Genetic variations in genes coding for hormones and growth factors involved in development of the breast are therefore of great interest. The associations between genetic polymorphisms in genes from the IGF pathway on mammographic density and circulating levels of IGF1, its binding protein IGFBP3, and their ratio in postmenopausal women are reported here. Methods Samples from 964 postmenopausal Norwegian women aged 55-71 years were collected as a part of the Tromsø Mammography and Breast Cancer Study. All samples were genotyped for 25 SNPs in IGF1, IGF2, IGF1R, IGF2R, IGFALS and IGFBP3 using Taqman (ABI. The main statistical analyses were conducted with the PROC HAPLOTYPE procedure within SAS/GENETICS™ (SAS 9.1.3. Results The haplotype analysis revealed six haploblocks within the studied genes. Of those, four had significant associations with circulating levels of IGF1 or IGFBP3 and/or mammographic density. One haplotype variant in the IGF1 gene was found to be associated with mammographic density. Within the IGF2 gene one haplotype variant was associated with levels of both IGF1 and IGFBP3. Two haplotype variants in the IGF2R were associated with the level of IGF1. Both variants of the IGFBP3 haplotype were associated with the IGFBP3 level and indicate regulation in cis. Conclusion Polymorphisms within the IGF1 gene and related genes were associated with plasma levels of IGF1, IGFBP3 and mammographic density in this study of postmenopausal women.

  9. False Negative Mammogram of Breast Cancer : Analysis of Mammographic and Sonographic Findings and Correlation with Clinical Findings

    International Nuclear Information System (INIS)

    Lee, Kil Jun; Lee, Ji Yeon; Han, Sung Nim; Jeong, Seong Ki; Tae, Seok; Shin, Kyoung Ja; Lee, Sang Chun

    1995-01-01

    Recent mammographic equipment have been of good quality and yielded high diagnostic accuracy for the detection of breast cancer. However, negative mammogram does not necessarily rule out breast cancer. Therefore were viewed cause of false negative mammography in confirmed breast cancer to improve diagnostic accuracy and for adequate clinical approach. We reviewed 19 cases of confirmed breast cancer, which showed false negative mammography with positive sonographic findings. Retrospective analysis was done by correlating the patient's age, sonographic finding and mass size, mammographic breast pattern and cause of false negative mammogram, and clinical symptoms. Among the 5 patients below 35 years in age, mass was not visible due to dense breast in 4 and due to small size in 1 case. In 14 patients over 35 years in age, 11 had normal mammographic findings, 4 had dense breast, and 7 had small sized mass. Remaining 3 cases showed asymmetric density in 2 and architecture distortion in 1 case. All showed mass lesion in sonography : ill defined malignant appearance in 14,well defined malignant appearance in 2, and well defined benign in 3 cases. Negative mammogram should be correlated with sonography in case of dense breast, below 35 years in age with palpable mass and under risk for breast cancer

  10. Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.

    Science.gov (United States)

    Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung

    2015-12-01

    The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic

  11. An Instructional Method for the AutoCAD Modeling Environment.

    Science.gov (United States)

    Mohler, James L.

    1997-01-01

    Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)

  12. Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

    International Nuclear Information System (INIS)

    Choi, Eun Jung; Jin, Gong Yong; Han, Young Min; Lee, Young Sun; Kweon, Keun Sang

    2008-01-01

    We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within ± 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. The CAD system was a useful tool for diagnosing malignant SPNs

  13. Contralateral lesions detected by preoperative MRI in patients with recently diagnosed breast cancer: Application of MR CAD in differentiation of benign and malignant lesions

    International Nuclear Information System (INIS)

    Cho, Nariya; Kim, Sun Mi; Park, Jeong Seon; Jang, Mijung; Kim, Soo-Yeon; Chang, Jung Min; Moon, Woo Kyung

    2012-01-01

    Objectives: To retrospectively investigate the added value of kinetic features measured by computer-aided diagnosis (CAD) for differentiating benign and malignant contralateral breast lesions detected by preoperative MRI in breast cancer patients. Methods: This study was approved by our institutional review board, and the requirement for informed consent was waived. Fifty-two breast MR images and their CAD kinetic features were obtained for 52 consecutive breast cancer patients with contralateral breast lesions detected by preoperative MRI and confirmed by excision (23 cancers and 29 benign lesions). Three experienced radiologists independently reviewed the MR images without CAD information and assessed probabilities of malignancy. Four weeks later, these probabilities were reanalyzed using stored CAD data. Diagnostic performances and detection rates of delayed washout components were compared between interpretations without and with CAD for each reader. Results: Use of MR CAD increased detection of washout component by 2.4- to 3.7-fold than visual assessment for enhancing contralateral lesions, which increased sensitivity (91% vs. 87% in reader 1; 96% vs. 74% in reader 2; 91% vs. 70% in reader 3) and decreased specificity, but statistical significance was only found for decreased specificity in one reader (52% vs. 28%, P = 0.039), and overall performance (areas under ROC curves 0.672 vs. 0.616 in reader 1; 0.624 vs. 0.603 in reader 2; 0.706 vs. 0.590 in reader 3) remained unimproved. Conclusion: Addition of MR CAD increased sensitivity and decreased specificity than radiologist's assessment alone for differentiating benign and malignant contralateral lesions in breast cancer patients and overall performance remained unimproved.

  14. Pulmonary nodules: Effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system—Comparison of performance between different-dose CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro, E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Honda, Osamu, E-mail: ohonda@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Kikuyama, Ayano, E-mail: a-kikuyama@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Gyobu, Tomoko, E-mail: t-gyobu@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Sumikawa, Hiromitsu, E-mail: h-sumikawa@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Koyama, Mitsuhiro, E-mail: m-koyama@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Tomiyama, Noriyuki, E-mail: tomiyama@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2012-10-15

    Purpose: To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Materials and methods: Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m{sup 2}) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. Results: The consensus panel found 265 non-calcified nodules ≤30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (p < 0.001). Mean number of false-positive findings per examination was significantly higher at 100%-ASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; p < 0.001). Effective doses were 10.77 ± 3.41 mSv in clinical routine-dose CT and 2.67 ± 0.17 mSv in lower-dose CT. Conclusion: CAD sensitivity at 100%-ASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings.

  15. Pulmonary nodules: Effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system—Comparison of performance between different-dose CT scans

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Honda, Osamu; Kikuyama, Ayano; Gyobu, Tomoko; Sumikawa, Hiromitsu; Koyama, Mitsuhiro; Tomiyama, Noriyuki

    2012-01-01

    Purpose: To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Materials and methods: Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m 2 ) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. Results: The consensus panel found 265 non-calcified nodules ≤30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (p < 0.001). Mean number of false-positive findings per examination was significantly higher at 100%-ASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; p < 0.001). Effective doses were 10.77 ± 3.41 mSv in clinical routine-dose CT and 2.67 ± 0.17 mSv in lower-dose CT. Conclusion: CAD sensitivity at 100%-ASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings

  16. AutoCAD-To-GIFTS Translator Program

    Science.gov (United States)

    Jones, Andrew

    1989-01-01

    AutoCAD-to-GIFTS translator program, ACTOG, developed to facilitate quick generation of small finite-element models using CASA/GIFTS finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Geometric entities recognized by ACTOG include points, lines, arcs, solids, three-dimensional lines, and three-dimensional faces. From this information, ACTOG creates GIFTS SRC file, which then reads into GIFTS preprocessor BULKM or modified and reads into EDITM to create finite-element model. SRC file used as is or edited for any number of uses. Written in Microsoft Quick-Basic (Version 2.0).

  17. Insulin-like growth factor-I (IGF-1), IGF-binding protein-3 (IGFBP-3) and mammographic features.

    Science.gov (United States)

    Izzo, L; Meggiorini, M L; Nofroni, I; Pala, A; De Felice, C; Meloni, P; Simari, T; Izzo, S; Pugliese, F; Impara, L; Merlini, G; Di Cello, P; Cipolla, V; Forcione, A R; Paliotta, A; Domenici, L; Bolognese, A

    2012-05-01

    The IGF system has recently been shown to play an important role in the regulation of breast tumor cell proliferation. However, also breast density is currently considered as the strongest breast cancer risk factor. It is not yet clear whether these factors are interrelated and if and how they are influenced by menopausal status. The purpose of this study was to examine the possible effects of IGF-1 and IGFBP-3 and IGF-1/IGFBP-3 molar ratio on mammographic density stratified by menopausal status. A group of 341 Italian women were interviewed to collect the following data: family history of breast cancer, reproductive and menstrual factors, breast biopsies, previous administration of hormonal contraceptive therapy, hormone replacement therapy (HRT) in menopause and lifestyle information. A blood sample was drawn for determination of IGF-1, IGFBP-3 levels. IGF-1/ IGFBP-3 molar ratio was then calculated. On the basis of recent mammograms the women were divided into two groups: dense breast (DB) and non-dense breast (NDB). Student's t-test was employed to assess the association between breast density and plasma level of IGF-1, IGFBP-3 and molar ratio. To assess if this relationship was similar in subgroups of pre- and postmenopausal women, the study population was stratified by menopausal status and Student's t-test was performed. Finally, multivariate analysis was employed to evaluate if there were confounding factors that might influence the relationship between growth factors and breast density. The analysis of the relationship between mammographic density and plasma level of IGF-1, IGFBP-3 and IGF-1/ IGFBP-3 molar ratio showed that IGF-1 levels and molar ratio varied in the two groups resulting in higher mean values in the DB group (IGF-1: 109.6 versus 96.6 ng/ml; p= 0.001 and molar ratio 29.4 versus 25.5 ng/ml; p= 0.001) whereas IGFBP-3 showed similar values in both groups (DB and NDB). Analysis of plasma level of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio

  18. Residential traffic noise and mammographic breast density in the Diet, Cancer, and Health cohort

    DEFF Research Database (Denmark)

    Roswall, Nina; Andersen, Zorana Jovanovic; von Euler-Chelpin, My

    2018-01-01

    OBJECTIVES: Traffic is the most important source of community noise, and it has been proposed to be associated with a range of disease outcomes, including breast cancer. As mammographic breast density (MD) is one of the strongest risk factors for developing breast cancer, the present study...

  19. Deactivation of the E. coli pH stress sensor CadC by cadaverine.

    Science.gov (United States)

    Haneburger, Ina; Fritz, Georg; Jurkschat, Nicole; Tetsch, Larissa; Eichinger, Andreas; Skerra, Arne; Gerland, Ulrich; Jung, Kirsten

    2012-11-23

    At acidic pH and in the presence of lysine, the pH sensor CadC activates transcription of the cadBA operon encoding the lysine/cadaverine antiporter CadB and the lysine decarboxylase CadA. In effect, these proteins contribute to acid stress adaptation in Escherichia coli. cadBA expression is feedback inhibited by cadaverine, and a cadaverine binding site is predicted within the central cavity of the periplasmic domain of CadC on the basis of its crystallographic analysis. Our present study demonstrates that this site only partially accounts for the cadaverine response in vivo. Instead, evidence for a second, pivotal binding site was collected, which overlaps with the pH-responsive patch of amino acids located at the dimer interface of the periplasmic domain. The temporal response of the E. coli Cad module upon acid shock was measured and modeled for two CadC variants with mutated cadaverine binding sites. These studies supported a cascade-like binding and deactivation model for the CadC dimer: binding of cadaverine within the pair of central cavities triggers a conformational transition that exposes two further binding sites at the dimer interface, and the occupation of those stabilizes the inactive conformation. Altogether, these data represent a striking example for the deactivation of a pH sensor. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Implementasi Penggunaan Aplikasi AutoCAD dalam Meningkatkan Kompetensi Dasar Menggambar teknik bagi Masyarakat

    Directory of Open Access Journals (Sweden)

    Risma Dwi Atmajayani

    2018-05-01

    Full Text Available Dengan berkembangnya teknologi, maka gambarpun ikut mengalami kemajuan dalam penggunaannya. Dengan kecanggihan dan kemajuan teknologi dapat melahirkan suatu cara menggambar dengan media komputer. Teknologi dapat membantu mempercepat menyelesaikan suatu pekerjaan, tidak terkecuali aplikasi CAD (Computer Aided Design. Program yang sering digunakan untuk pengajaran CAD adalah AutoCAD yang merupakan sebuah aplikasi (software yang digunakan untuk menggambar, mendesain gambar, menguji material dimana program tersebut mempunyai kemudahan dan keunggulan untuk membuat gambar secara tepat dan akurat. Berdasarkan temuan dilapangan yang didasari tinjauan langsung, didapatkan informasi bahwa materi AutoCAD yang diperoleh dari jenjang sebelumnya masih banyak yang jauh dari kondisi ideal. Materi AutoCAD yang didapatkan masih banyak tentang teori sedikit praktek, perangkat hardware yang terbatas sampai pada ketersediaan sumber daya manusia yang kurang adalah permasalahan umum yang terjadi. Adapun tujuan yang ingin dicapai adalah (1 Meningkatkan mutu peserta pelatihan melalui workshop pemanfaatan aplikasi AutoCAD (2 Meningkatkan ketrampilan peserta pelatihan dengan membuat suatu proyek desain gambar bangun berbasis aplikasi AutoCAD. Manfaat kegiatan pelatihan adalah: (1 Peserta pelatihan dapat meningkatkan pemahaman tentang program AutoCAD; (2 Peserta pelatihan dapat menyalurkan pengetahuan dan ketrampilan yang didapatkan nantinya kepada yang membutuhkan dan terutama akan sangat membantu para calon civil engineer dalam menyelesaikan pekerjaan yang berkaitan dengan desain rancang bangun; (3 Peserta pelatihan dapat mendesain gambar menggunakan program AutoCAD.

  1. Complete PCB design using OrCAD capture and layout

    CERN Document Server

    Mitzner, Kraig

    2011-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The book is written for both students and practicing engineers who need a quick tutorial on how to use the software and who need in-depth knowledge of the capabilities and limitations of the software package. There are two goals the book aims to reach:The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Layout. Capture is used to build the schematic diagram of the circuit, and Layout is used to design the circuit board so that

  2. CAD/CAM: improved design quality, increased productivity

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D. E.; England, J.

    1980-01-01

    Maintaining productivity levels while assuring the quality of engineering products grows increasingly more difficult and costly for industries such as the energy industry which are heavily committed to product design. The man/machine interface made possible through the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology can be applied to the design process as a tool for increased control to assure the quality of the final engineering product. The quality-control aspects of CAD/CAM technology are addressed in this presentation.

  3. Clinicopathogical characteristics and mammographic features of breast cancer showing architectural distortion on a mammogram

    International Nuclear Information System (INIS)

    Kanzaki, Masao; Hirose, Naoko; Suwa, Kaori; Yoshida, Masayuki; Otuki, Yoshiro; Kobayashi, Hiroshi

    2012-01-01

    Seven hundred and twenty-seven cases of breast cancer were diagnosed in this clinic between January 2003 and December 2010. Of those, 97 patients who showed architectural distortion on mammography were examined regarding the clinicopathological characteristics and mammographic features. The overall rate of architectural distortion was 13.3%, which became higher with progression of the clinical stage. The rate of lymph node metastasis was 50.5% histologically, and the most common histological type was scirrhous carcinoma at 36.2%, papillotubular carcinoma at 33%, invasive lobular carcinoma at 12.1%, and ductal carcinoma in situ at 11%. Cases of extensive ductal spread beyond the breast quadrant, accompanied by microcalcifications or showing architectural distortion in two views on mammography, were present at significantly high rates. Cases showing architectural distortion in two views on mammography accounted for 66% of the total, and, when these cases were not associated with any other mammographic findings, the most suspected histology of the lesion was invasive lobular carcinoma or carcinoma in situ. (author)

  4. Association of infertility and fertility treatment with mammographic density in a large screening-based cohort of women: a cross-sectional study.

    Science.gov (United States)

    Lundberg, Frida E; Johansson, Anna L V; Rodriguez-Wallberg, Kenny; Brand, Judith S; Czene, Kamila; Hall, Per; Iliadou, Anastasia N

    2016-04-13

    Ovarian stimulation drugs, in particular hormonal agents used for controlled ovarian stimulation (COS) required to perform in vitro fertilization, increase estrogen and progesterone levels and have therefore been suspected to influence breast cancer risk. This study aims to investigate whether infertility and hormonal fertility treatment influences mammographic density, a strong hormone-responsive risk factor for breast cancer. Cross-sectional study including 43,313 women recruited to the Karolinska Mammography Project between 2010 and 2013. Among women who reported having had infertility, 1576 had gone through COS, 1429 had had hormonal stimulation without COS and 5958 had not received any hormonal fertility treatment. Percent and absolute mammographic densities were obtained using the volumetric method Volpara™. Associations with mammographic density were assessed using multivariable generalized linear models, estimating mean differences (MD) with 95 % confidence intervals (CI). After multivariable adjustment, women with a history of infertility had 1.53 cm(3) higher absolute dense volume compared to non-infertile women (95 % CI: 0.70 to 2.35). Among infertile women, only those who had gone through COS treatment had a higher absolute dense volume than those who had not received any hormone treatment (adjusted MD 3.22, 95 % CI: 1.10 to 5.33). No clear associations were observed between infertility, fertility treatment and percent volumetric density. Overall, women reporting infertility had more dense tissue in the breast. The higher absolute dense volume in women treated with COS may indicate a treatment effect, although part of the association might also be due to the underlying infertility. Continued monitoring of cancer risk in infertile women, especially those who undergo COS, is warranted.

  5. Research on remote sensing image pixel attribute data acquisition method in AutoCAD

    Science.gov (United States)

    Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui

    2013-07-01

    The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.

  6. Selective magnetic resonance imaging (MRI) in invasive lobular breast cancer based on mammographic density: does it lead to an appropriate change in surgical treatment?

    Science.gov (United States)

    Bansal, Gaurav J; Santosh, Divya; Davies, Eleri L

    2016-01-01

    The purpose of this study was to evaluate whether high mammographic density can be used as one of the selection criteria for MRI in invasive lobular breast cancer (ILC). In our institute, high breast density has been used as one of the indications for performing MRI scan in patients with ILC. We divided the patients in two groups, one with MRI performed pre-operatively and other without MRI. We compared their surgical procedures and analyzed whether surgical plan was altered after MRI. In case of alteration of plan, we analyzed whether the change was adequate by comparing post-operative histological findings. Between 2011 and 2015, there were a total of 1601 breast cancers with 97 lobular cancers, out of which 36 had pre-operative MRI and 61 had no MRI scan. 12 (33.3%) had mastectomy following MRI, out of which 9 (25%) had change in surgical plan from conservation to mastectomy following MRI. There were no unnecessary mastectomies in the MRI group. However, utilization of MRI in this cohort of patients did not reduce reoperation rate (19.3%). Lobular carcinoma in situ (LCIS) was identified in 60% of reoperations on post-surgical histology. Patients in the "No MRI" group had higher mastectomy rate 26 (42.6%), which was again appropriate. High mammographic density is a useful risk stratification criterion for selective MRI in ILC within a multidisciplinary team meeting setting. Provided additional lesions identified on MRI are confirmed with biopsy, pre-operative MRI does not cause unnecessary mastectomies. Used in this selective manner, reoperation rates were not eliminated, albeit reduced when compared to literature. High mammographic breast density can be used as one of the selection criteria for pre-operative MRI in ILC without an increase in inappropriate mastectomies with potential time and cost savings. In this cohort, re-excisions were not reduced markedly with pre-operative MRI.

  7. Mammographic Imaging Studies Using the Monte Carlo Image Simulation-Differential Sampling (MCMIS-DS) Code

    International Nuclear Information System (INIS)

    Kuruvilla Verghese

    2002-01-01

    This report summarizes the highlights of the research performed under the 1-year NEER grant from the Department of Energy. The primary goal of this study was to investigate the effects of certain design changes in the Fisher Senoscan mammography system and in the degree of breast compression on the discernability of microcalcifications in calcification clusters often observed in mammograms with tumor lesions. The most important design change that one can contemplate in a digital mammography system to improve resolution of calcifications is the reduction of pixel dimensions of the digital detector. Breast compression is painful to the patient and is though to be a deterrent to women to get routine mammographic screening. Calcification clusters often serve as markers (indicators ) of breast cancer

  8. Trends in CAD education in interior design programs

    OpenAIRE

    Ko, Hye Mi

    1990-01-01

    This research investigated Computer Aided Design (CAD) education in the interior design. program focusing on educators' opinions about creativity aspects including computer application, teaching materials and teaching methods as well as other trends in CAD education. A questionnaire was sent to one hundred eighty-two members of the Interior Design Educators Council (IDEC). A frequency distribution was used on 69 usable returned surveys to describe the sample characteristi...

  9. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    Science.gov (United States)

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. A new data integration approach for AutoCAD and GIS

    Science.gov (United States)

    Ye, Hongmei; Li, Yuhong; Wang, Cheng; Li, Lijun

    2006-10-01

    GIS has its advantages both on spatial data analysis and management, particularly on the geometric and attributive information management, which has also attracted lots attentions among researchers around world. AutoCAD plays more and more important roles as one of the main data sources of GIS. Various work and achievements can be found in the related literature. However, the conventional data integration from AutoCAD to GIS is time-consuming, which also can cause the information loss both in the geometric aspects and the attributive aspects for a large system. It is necessary and urgent to sort out new approach and algorithm for the efficient high-quality data integration. In this paper, a novel data integration approach from AutoCAD to GIS will be introduced based on the spatial data mining technique through the data structure analysis both in the AutoCAD and GIS. A practicable algorithm for the data conversion from CAD to GIS will be given as well. By a designed evaluation scheme, the accuracy of the conversion both in the geometric and the attributive information will be demonstrated. Finally, the validity and feasibility of the new approach will be shown by an experimental analysis.

  11. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    Science.gov (United States)

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p CAD/CAM PMMA-based M (p CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  12. Assessment of the Use of AutoCAD in Mechanical Engineering Technical Drawing Education

    OpenAIRE

    Akyürek, Turgut

    2018-01-01

    AutoCAD is one of the widely used software tools in engineering education. In this study, ageneral assessment of AutoCAD for the usage in the mechanical engineering technical drawing educationis made. AutoCAD is assessed in terms of the fulfilment of the requirements defined for the main twotechnical drawing courses. AutoCAD is assessed in terms of its capability in meeting the requirements ofthe technical drawing courses.

  13. User interface issues in radiotherapy CAD software. 116

    International Nuclear Information System (INIS)

    Sherouse, G.W.; Mosher, C.E. Jr.

    1987-01-01

    A major growth area in computerized planning of radiotherapy over the last five years has been the development of programs for treatment design based on the interactive graphic display of three dimensional patient models. This word has been recognized as being a close relative of Computer-Aided Design (CAD) software which is used in industry for a broad spectrum of engineering and design applications. A CAD system for radiotherapy has been constructed which combines some of the more attractive aspects of other institutions' treatment design systems with CAD technology and a user interface which is designed for use by clinicians. The importance of an appropriate user interface cannot be overemphasized and is often sadly neglected in radiotherapy software. In order to realize the potential of this new treatment design technology it is essential that clinicians, particularly physicians, perceive RT CAD systems as tools rather than as obstacles. It is felt that thhe best way to achieve that perception is for the software to implement a superset of the functions used in conventional practice while retaining the ambiance of the traditional methods. It is the aim to construct a system which an experienced physician or dosimetrist can use with essentially no retraining. The model for this CAD tool is that of a virtual simulator. It is meant to faithfully reproduce both the function and the feel of a physical simulator. A number of techniques has been identified for realizing this goal. These include simple intuitive input devices, natural coordinate systems graphic interaction, good interactive responsiveness, and high-quality 3D display modalities. Here a description of these techniques and some details of their implementation is presented. 10 refs.; 2 figs

  14. Format conversion between CAD data and GIS data based on ArcGIS

    Science.gov (United States)

    Xie, Qingqing; Wei, Bo; Zhang, Kailin; Wang, Zhichao

    2015-12-01

    To make full use of the data resources and realize a sharing for the different types of data in different industries, a method of format conversion between CAD data and GIS data based on ArcGIS was proposed. To keep the integrity of the converted data, some key steps to process CAD data before conversion were made in AutoCAD. For examples, deleting unnecessary elements such as title, border and legend avoided the appearance of unnecessary elements after conversion, as layering data again by a national standard avoided the different types of elements to appear in a same layer after conversion. In ArcGIS, converting CAD data to GIS data was executed by the correspondence of graphic element classification between AutoCAD and ArcGIS. In addition, an empty geographic database and feature set was required to create in ArcGIS for storing the text data of CAD data. The experimental results show that the proposed method avoids a large amount of editing work in data conversion and maintains the integrity of spatial data and attribute data between before and after conversion.

  15. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  16. Tumor characteristics and family history in relation to mammographic density and breast cancer: The French E3N cohort.

    Science.gov (United States)

    Maskarinec, Gertraud; Dartois, Laureen; Delaloge, Suzette; Hopper, John; Clavel-Chapelon, Françoise; Baglietto, Laura

    2017-08-01

    Mammographic density is a known heritable risk factor for breast cancer, but reports how tumor characteristics and family history may modify this association are inconsistent. Dense and total breast areas were assessed using Cumulus™ from pre-diagnostic mammograms for 820 invasive breast cancer cases and 820 matched controls nested within the French E3N cohort study. To allow comparisons across models, percent mammographic density (PMD) was standardized to the distribution of the controls. Odds ratios (OR) and 95% confidence intervals (CI) of breast cancer risk for mammographic density were estimated by conditional logistic regression while adjusting for age and body mass index. Heterogeneity according to tumor characteristic and family history was assessed using stratified analyses. Overall, the OR per 1 SD for PMD was 1.50 (95% CI, 1.33-1.69). No evidence for significant heterogeneity by tumor size, lymph node status, grade, and hormone receptor status (estrogen, progesterone, and HER2) was detected. However, the association of PMD was stronger for women reporting a family history of breast cancer (OR 1SD =2.25; 95% CI, 1.67-3.04) than in women reporting none (OR 1SD =1.41; 95% CI, 1.24-1.60; p heterogeneity =0.002). Similarly, effect modification by FHBC was observed using categories of PMD (p heterogeneity =0.02) with respective ORs of 15.16 (95% CI, 4.23-54.28) vs. 3.14 (95% CI, 1.89-5.22) for ≥50% vs. breast cancer risk with a family history supports the hypothesis of shared genetic factors responsible for familial aggregation of breast cancer and the heritable component of mammographic density. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Double-blind randomized 12-month soy intervention had no effects on breast MRI fibroglandular tissue density or mammographic density

    Science.gov (United States)

    Wu, Anna H.; Spicer, Darcy; Garcia, Agustin; Tseng, Chiu-Chen; Hovanessian-Larsen, Linda; Sheth, Pulin; Martin, Sue Ellen; Hawes, Debra; Russell, Christy; McDonald, Heather; Tripathy, Debu; Su, Min-Ying; Ursin, Giske; Pike, Malcolm C.

    2015-01-01

    Soy supplementation by breast cancer patients remains controversial. No controlled intervention studies have investigated the effects of soy supplementation on mammographic density in breast cancer patients. We conducted a double-blind, randomized, placebo-controlled intervention study in previously treated breast cancer patients (n=66) and high-risk women (n=29). We obtained digital mammograms and breast magnetic resonance imaging (MRI) scans at baseline and after 12 months of daily soy (50 mg isoflavones per day) (n=46) or placebo (n=49) tablet supplementation. The total breast area (MA) and the area of mammographic density (MD) on the mammogram was measured using a validated computer-assisted method, and mammographic density percent (MD% = 100 × MD/MA) was determined. A well-tested computer algorithm was used to quantitatively measure the total breast volume (TBV) and fibroglandular tissue volume (FGV) on the breast MRI, and the FGV percent (FGV% = 100 × FGV/TBV) was calculated. On the basis of plasma soy isoflavone levels, compliance was excellent. Small decreases in MD% measured by the ratios of month 12 to baseline levels, were seen in the soy (0.95) and the placebo (0.87) groups; these changes did not differ between the treatments (P=0.38). Small decreases in FGV% were also found in both the soy (0.90) and the placebo (0.92) groups; these changes also did not differ between the treatments (P=0.48). Results were comparable in breast cancer patients and high-risk women. We found no evidence that soy supplementation would decrease mammographic density and that MRI might be more sensitive to changes in density than mammography. PMID:26276750

  18. CAD-based automatic modeling method for Geant4 geometry model through MCAM

    International Nuclear Information System (INIS)

    Wang, D.; Nie, F.; Wang, G.; Long, P.; LV, Z.

    2013-01-01

    The full text of publication follows. Geant4 is a widely used Monte Carlo transport simulation package. Before calculating using Geant4, the calculation model need be established which could be described by using Geometry Description Markup Language (GDML) or C++ language. However, it is time-consuming and error-prone to manually describe the models by GDML. Automatic modeling methods have been developed recently, but there are some problems that exist in most present modeling programs, specially some of them were not accurate or adapted to specifically CAD format. To convert the GDML format models to CAD format accurately, a Geant4 Computer Aided Design (CAD) based modeling method was developed for automatically converting complex CAD geometry model into GDML geometry model. The essence of this method was dealing with CAD model represented with boundary representation (B-REP) and GDML model represented with constructive solid geometry (CSG). At first, CAD model was decomposed to several simple solids which had only one close shell. And then the simple solid was decomposed to convex shell set. Then corresponding GDML convex basic solids were generated by the boundary surfaces getting from the topological characteristic of a convex shell. After the generation of these solids, GDML model was accomplished with series boolean operations. This method was adopted in CAD/Image-based Automatic Modeling Program for Neutronics and Radiation Transport (MCAM), and tested with several models including the examples in Geant4 install package. The results showed that this method could convert standard CAD model accurately, and can be used for Geant4 automatic modeling. (authors)

  19. Solid modeling and applications rapid prototyping, CAD and CAE theory

    CERN Document Server

    Um, Dugan

    2016-01-01

    The lessons in this fundamental text equip students with the theory of Computer Assisted Design (CAD), Computer Assisted Engineering (CAE), the essentials of Rapid Prototyping, as well as practical skills needed to apply this understanding in real world design and manufacturing settings. The book includes three main areas: CAD, CAE, and Rapid Prototyping, each enriched with numerous examples and exercises. In the CAD section, Professor Um outlines the basic concept of geometric modeling, Hermite and Bezier Spline curves theory, and 3-dimensional surface theories as well as rendering theory. The CAE section explores mesh generation theory, matrix notion for FEM, the stiffness method, and truss Equations. And in Rapid Prototyping, the author illustrates stereo lithographic theory and introduces popular modern RP technologies. Solid Modeling and Applications: Rapid Prototyping, CAD and CAE Theory is ideal for university students in various engineering disciplines as well as design engineers involved in product...

  20. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  1. External validation of a publicly available computer assisted diagnostic tool for mammographic mass lesions with two high prevalence research datasets.

    Science.gov (United States)

    Benndorf, Matthias; Burnside, Elizabeth S; Herda, Christoph; Langer, Mathias; Kotter, Elmar

    2015-08-01

    Lesions detected at mammography are described with a highly standardized terminology: the breast imaging-reporting and data system (BI-RADS) lexicon. Up to now, no validated semantic computer assisted classification algorithm exists to interactively link combinations of morphological descriptors from the lexicon to a probabilistic risk estimate of malignancy. The authors therefore aim at the external validation of the mammographic mass diagnosis (MMassDx) algorithm. A classification algorithm like MMassDx must perform well in a variety of clinical circumstances and in datasets that were not used to generate the algorithm in order to ultimately become accepted in clinical routine. The MMassDx algorithm uses a naïve Bayes network and calculates post-test probabilities of malignancy based on two distinct sets of variables, (a) BI-RADS descriptors and age ("descriptor model") and (b) BI-RADS descriptors, age, and BI-RADS assessment categories ("inclusive model"). The authors evaluate both the MMassDx (descriptor) and MMassDx (inclusive) models using two large publicly available datasets of mammographic mass lesions: the digital database for screening mammography (DDSM) dataset, which contains two subsets from the same examinations-a medio-lateral oblique (MLO) view and cranio-caudal (CC) view dataset-and the mammographic mass (MM) dataset. The DDSM contains 1220 mass lesions and the MM dataset contains 961 mass lesions. The authors evaluate discriminative performance using area under the receiver-operating-characteristic curve (AUC) and compare this to the BI-RADS assessment categories alone (i.e., the clinical performance) using the DeLong method. The authors also evaluate whether assigned probabilistic risk estimates reflect the lesions' true risk of malignancy using calibration curves. The authors demonstrate that the MMassDx algorithms show good discriminatory performance. AUC for the MMassDx (descriptor) model in the DDSM data is 0.876/0.895 (MLO/CC view) and AUC

  2. Author Details

    African Journals Online (AJOL)

    Rae, W. Vol 12, No 2 (2008) - Articles Computed Radiography Exposure Indices in Mammography Abstract PDF · Vol 13, No 3 (2009) - Articles Mammographic CAD: Correlation of regions in ipsilateral views – a pilot study. Abstract PDF · Vol 13, No 4 (2009) - Articles The relationship between compression force, image ...

  3. A novel and automatic mammographic texture resemblance marker is an independent risk factor for breast cancer

    DEFF Research Database (Denmark)

    Nielsen, Mads; Karemore, Gopal; Loog, Marco

    2011-01-01

    Objective: We investigated whether breast cancer is predicted by a breast cancer risk mammographic texture resemblance (MTR) marker. Methods: A previously published case-control study included 495 women of which 245 were diagnosed with breast cancer. In baseline mammograms, 2-4 years prior...... to diagnosis, the following mammographic parameters were analysed for relation to breast cancer risk: (C) categorical parenchymal pattern scores; (R) radiologist's percentage density, (P) computer-based percentage density; (H) computer-based breast cancer risk MTR marker; (E) computer-based hormone replacement...... treatment MTR marker; and (A) an aggregate of P and H. Results: Density scores, C, R, and P correlated (tau=0.3-0.6); no other pair of scores showed large (tau>0.2) correlation. For the parameters, the odds ratios of future incidence of breast cancer comparing highest to lowest categories (146 and 106...

  4. Mass detection in digital breast tomosynthesis: Deep convolutional neural network with transfer learning from mammography.

    Science.gov (United States)

    Samala, Ravi K; Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A; Wei, Jun; Cha, Kenny

    2016-12-01

    Develop a computer-aided detection (CAD) system for masses in digital breast tomosynthesis (DBT) volume using a deep convolutional neural network (DCNN) with transfer learning from mammograms. A data set containing 2282 digitized film and digital mammograms and 324 DBT volumes were collected with IRB approval. The mass of interest on the images was marked by an experienced breast radiologist as reference standard. The data set was partitioned into a training set (2282 mammograms with 2461 masses and 230 DBT views with 228 masses) and an independent test set (94 DBT views with 89 masses). For DCNN training, the region of interest (ROI) containing the mass (true positive) was extracted from each image. False positive (FP) ROIs were identified at prescreening by their previously developed CAD systems. After data augmentation, a total of 45 072 mammographic ROIs and 37 450 DBT ROIs were obtained. Data normalization and reduction of non-uniformity in the ROIs across heterogeneous data was achieved using a background correction method applied to each ROI. A DCNN with four convolutional layers and three fully connected (FC) layers was first trained on the mammography data. Jittering and dropout techniques were used to reduce overfitting. After training with the mammographic ROIs, all weights in the first three convolutional layers were frozen, and only the last convolution layer and the FC layers were randomly initialized again and trained using the DBT training ROIs. The authors compared the performances of two CAD systems for mass detection in DBT: one used the DCNN-based approach and the other used their previously developed feature-based approach for FP reduction. The prescreening stage was identical in both systems, passing the same set of mass candidates to the FP reduction stage. For the feature-based CAD system, 3D clustering and active contour method was used for segmentation; morphological, gray level, and texture features were extracted and merged with a

  5. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD

  6. Studies on computer-aided diagnosis systems for chest radiographs and mammograms (in Japanese)

    International Nuclear Information System (INIS)

    Hara, Takeshi

    2001-01-01

    This thesis describes computer-aided diagnosis (CAD) systems for chest radiographs and mammograms. Preprocessing and imaging processing methods for each CAD system include dynamic range compression and region segmentation technique. A new pattern recognition technique combines genetic algorithms with template matching methods to detect lung nodules. A genetic algorithm was employed to select the optimal shape of simulated nodular shadows to be compared with real lesions on digitized chest images. Detection performance was evaluated using 332 chest radiographs from the database of the Japanese Society of Radiological Technology. Our average true-positive rate was 72.8% with an average of 11 false-positive findings per image. A new detection method using high resolution digital images with 0.05 mm sampling is also proposed for the mammogram CAD system to detect very small microcalcifications. An automated classification method uses feature extraction based on fractal dimension analysis of masses. Using over 200 cases to evaluate the detection of mammographic masses and calcifications, the detection rate of masses and microcalcifications were 87% and 96% with 1.5 and 1.8 false-positive findings, respectively. The classification performance on benign vs malignant lesions, the Az values that were defined by the areas under the ROC curves derived from classification schemes of masses and microcalcifications were 0.84 and 0.89. To demonstrate the practicality of these CAD systems in a computer-network environment, we propose to use the mammogram CAD system via the Internet and WWW. A common gateway interface and server-client approach for the CAD system via the Internet will permit display of the CAD results on ordinary computers

  7. Utilização do AutoCAD 2004 para quantificação de pesquisas usando fotomicrografias eletrônicas AutoCAD 2004 to quantify electron-photomicrography

    Directory of Open Access Journals (Sweden)

    Carla Albertina Martins Almeida

    2007-08-01

    Full Text Available OBJETIVO: Avaliar o uso do programa AutoCAD 2004 para estudos quantitativos em microscopia eletrônica. MÉTODOS: A demonstração da utilização do AutoCAD 2004 foi feita em um modelo experimental de diabetes induzido em ratos, divididos em Grupo Controle (GC-10 animais e Grupo Diabético (GD - 10 animais, avaliados 1 mês depois da indução do diabetes. Os olhos foram removidos após o sacrifício dos animais e preparados para exame em microscópio eletrônico, tendo sido feitas fotografias dos vasos retinianos. Foi utilizado o programa AutoCAD2004 para avaliar a espessura da membrana basal dos vasos. Os resultados foram avaliados estatisticamente. RESULTADOS: Usando o método proposto foi possível realizar medidas quantitativas na membrana basal de vasos retinianos de ratos diabéticos. CONCLUSÃO: O AutoCAD 2004 se mostrou efetivo, seguro e de fácil utilização para a quantificação de fenômenos biológicos, sendo possível sugerir este meio para a realização de avaliações quantitativas em experimentos biológicos.OBJECTIVE: To determine if the AutoCAD 2004 program is available to be used in quantitative research on electron microscopy. METHODS: A demonstrative of the AutoCAD2004 was done in an experimental model of diabetes induced in rats. The animals were divided by lot in control group animals (GC-10 animals and diabetic group (GD - 10 animals, evaluated 1 month after the diabetes induction. The eyes were removed after sacrifice and prepared to electron microscopy. The retina was photographed and the AutoCAD2004 program was used to measure the basal membrane of retina vessels. The results were submitted to statistical analysis. RESULTS: The AutoCAD2004 was effective to obtain quantitative measures from the basal membrane of retina vessels and there were no difference between the studied groups. CONCLUSION: The AutoCAD2004 was effective, safe and easy to apply to quantify biological parameters, which allowed suggest it to

  8. Classification of mammographic masses using geometric symmetry and fractal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Guo Qi; Ruiz, V.F. [Cybernetics, School of Systems Engineering, Univ. of Reading (United Kingdom); Shao Jiaqing [Dept. of Electronics, Univ. of Kent (United Kingdom); Guo Falei [WanDe Industrial Engineering Co. (China)

    2007-06-15

    In this paper, we propose a fuzzy symmetry measure based on geometrical operations to characterise shape irregularity of mammographic mass lesion. Group theory, a powerful tool in the investigation of geometric transformation, is employed in our work to define and describe the underlying mathematical relations. We investigate the usefulness of fuzzy symmetry measure in combination with fractal analysis for classification of masses. Comparative studies show that fuzzy symmetry measure is useful for shape characterisation of mass lesions and is a good complementary feature for benign-versus-malignant classification of masses. (orig.)

  9. Force balancing in mammographic compression

    International Nuclear Information System (INIS)

    Branderhorst, W.; Groot, J. E. de; Lier, M. G. J. T. B. van; Grimbergen, C. A.; Neeter, L. M. F. H.; Heeten, G. J. den; Neeleman, C.

    2016-01-01

    Purpose: In mammography, the height of the image receptor is adjusted to the patient before compressing the breast. An inadequate height setting can result in an imbalance between the forces applied by the image receptor and the paddle, causing the clamped breast to be pushed up or down relative to the body during compression. This leads to unnecessary stretching of the skin and other tissues around the breast, which can make the imaging procedure more painful for the patient. The goal of this study was to implement a method to measure and minimize the force imbalance, and to assess its feasibility as an objective and reproducible method of setting the image receptor height. Methods: A trial was conducted consisting of 13 craniocaudal mammographic compressions on a silicone breast phantom, each with the image receptor positioned at a different height. The image receptor height was varied over a range of 12 cm. In each compression, the force exerted by the compression paddle was increased up to 140 N in steps of 10 N. In addition to the paddle force, the authors measured the force exerted by the image receptor and the reaction force exerted on the patient body by the ground. The trial was repeated 8 times, with the phantom remounted at a slightly different orientation and position between the trials. Results: For a given paddle force, the obtained results showed that there is always exactly one image receptor height that leads to a balance of the forces on the breast. For the breast phantom, deviating from this specific height increased the force imbalance by 9.4 ± 1.9 N/cm (6.7%) for 140 N paddle force, and by 7.1 ± 1.6 N/cm (17.8%) for 40 N paddle force. The results also show that in situations where the force exerted by the image receptor is not measured, the craniocaudal force imbalance can still be determined by positioning the patient on a weighing scale and observing the changes in displayed weight during the procedure. Conclusions: In mammographic breast

  10. A visual LISP program for voxelizing AutoCAD solid models

    Science.gov (United States)

    Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz

    2015-01-01

    AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.

  11. Lung nodule detection on chest CT: evaluation of a computer-aided detection (CAD) system

    International Nuclear Information System (INIS)

    Lee, In Jae; Gamsu, Gordon; Czum, Julianna; Johnson, Rebecca; Chakrapani, Sanjay; Wu, Ning

    2005-01-01

    To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results

  12. Image enhancement by using IDL for a mammographic x-ray image in Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Md Saion Salikin; Wan Hazlinda Ismail; Norriza Mohd Isa; Azuhar Ripin

    2004-01-01

    Digital image enhancement technique can have a significant impact on the diagnostic quality of a radiographic image. The main aim of image enhancement is to process the image so that the enhanced image is clearer and more useful for specific application. There are three types of image enhancement namely noise reduction, edge enhancement and contrast enhancement. The objective of this project is to enhance the mammographic image by using Interactive Data Language (IDL) software in spatial and frequency domain by using various methods. In spatial domain method, direct manipulation of pixel in an image is used whereas, in frequency domain method, modifying the spectral component or Fourier Transform of an image is used In order to obtain the good quality mammographic image, breast phantom Model 12A with 4.0 cm compressed thickness and Bennett Model DMF- 150 Mammography Machine with various kV and mA are employed. The results of enhanced image with selected technique by using IDL are presented in this paper. (Author)

  13. Introduction of effect and consideration of the introduction of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-12-01

    This reports introduction of effect and consideration of the introduction of computer-aided design and computer aided manufacturing system. It includes outline of CAD/CAM system like definition, classification, system kinds, and development process of CAD/CAM system, technology, market trend development prospect, and value on introduction of this system, and current application of CAD/CAM system in major application area, development countries and Korea.

  14. Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

    International Nuclear Information System (INIS)

    Malkov, Serghei; Wang, Jeff; Kerlikowske, Karla; Cummings, Steven R.; Shepherd, John A.

    2009-01-01

    Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a ±2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

  15. Discoloration of various CAD/CAM blocks after immersion in coffee

    Directory of Open Access Journals (Sweden)

    Sasipin Lauvahutanon

    2017-02-01

    Full Text Available Objectives This study evaluated color differences (ΔEs and translucency parameter changes (ΔTPs of various computer-aided design/computer-aided manufacturing (CAD/CAM blocks after immersion in coffee. Materials and Methods Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L*a*b* values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6. The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05. The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent. The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC. There was no significant correlation between ΔEs and water sorption or solubility in water. Conclusions The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  16. Does the accuracy of single reading with CAD (computer-aided detection) compare with that of double reading?: A review of the literature

    International Nuclear Information System (INIS)

    Bennett, R.L.; Blanks, R.G.; Moss, S.M.

    2006-01-01

    Aim: To examine current evidence to determine whether the accuracy of single reading with computed-aided detection (CAD) compares with that of double reading. Methods: We performed a literature review to identify studies where both protocols had been investigated and compared. We identified eight studies that compared single reading with CAD against double reading, of which six reported on comparisons of both sensitivity and specificity. Results: Of the six studies identified, three showed no differences in either sensitivity or specificity. One showed single reading with CAD had a higher sensitivity at the same specificity, another that single reading with CAD had a higher specificity at the same sensitivity. However, one study, in a real-life setting, showed that single reading with CAD had a higher sensitivity but a lower specificity. Conclusion: As the majority of the studies were not in a real-life setting, used test sets, lacked sufficient training in the use of CAD and simulated double reading (using a protocol of recall if one suggests), current evidence is therefore limited as to the accuracy, in terms of sensitivity and specificity, of single reading with CAD in comparison with the most common practice in the UK of double reading using a protocol of consensus or arbitration

  17. Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group.

    Science.gov (United States)

    Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R

    2000-09-01

    To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.

  18. Computer-aided detection (CAD) in mammography: Does it help the junior or the senior radiologist?

    International Nuclear Information System (INIS)

    Balleyguier, Corinne; Kinkel, Karen; Fermanian, Jacques; Malan, Sebastien; Djen, Germaine; Taourel, Patrice; Helenon, Olivier

    2005-01-01

    Objectives: To evaluate the impact of a computer-aided detection (CAD) system on the ability of a junior and senior radiologist to detect breast cancers on mammograms, and to determine the potential of CAD as a teaching tool in mammography. Methods: Hundred biopsy-proven cancers and 100 normal mammograms were randomly analyzed by a CAD system. The sensitivity (Se) and specificity (Sp) of the CAD system were calculated. In the second phase, to simulate daily practice, 110 mammograms (97 normal or with benign lesions, and 13 cancers) were examined independently by a junior and a senior radiologist, with and without CAD. Interpretations were standardized according to BI-RADS classification. Sensitivity, Specificity, positive and negative predictive values (PPV, NPV) were calculated for each session. Results: For the senior radiologist, Se slightly improved from 76.9 to 84.6% after CAD analysis (NS) (one case of clustered microcalcifications case overlooked by the senior radiologist was detected by CAD). Sp, PPV and PNV did not change significantly. For the junior radiologist, Se improved from 61.9 to 84.6% (significant change). Three cancers overlooked by the junior radiologist were detected by CAD. Sp was unchanged. Conclusion: CAD mammography proved more useful for the junior than for the senior radiologist, improving sensitivity. The CAD system may represent a useful educational tool for mammography

  19. Complete PCB design using OrCAD capture and PCB editor

    CERN Document Server

    Mitzner, Kraig

    2009-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Editor. Capture is used to build the schematic diagram of the circuit, and Editor is used to design the circuit board so that it can be manufactured. The book is written for both students and practicing engineers who need in-depth instruction on how to use the software, and who need background knowledge of the PCB design process. KEY FEATURES:* Beginning to end cove

  20. Barriers and facillitators to compliance with routine mammographic screening

    International Nuclear Information System (INIS)

    Kessler, H.B.; Rimer, B.; Keintz, M.K.; Myers, R.E.; Engstrom, P.F.

    1988-01-01

    Six hundred one randomly selected women were interviewed to determine their reasons for compliance or noncompliance with free HMO-sponsored mammographic examinations. Noncompliers were significantly more likely to believe mammograms are unnecessary without symptoms, too much trouble, or inconvenient and to perceive their physicians as not recommending mammograms. Compliers were more likely to believe that early breast cancer can be cured and to recognize that breast screening is for asymptomatic individuals. When cost is eliminated as a barrier to screening, a variety of socioeconomic, psychological, and access barriers are exposed. Radiologists must be cognizant of these factors in planning and participating in breast cancer screening programs