WorldWideScience

Sample records for malaysian office buildings

  1. MALAYSIAN WEATHER DATA (TRY) FOR ENERGY SIMULATIONS IN BUILDINGS

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter

    2001-01-01

    Detailed energy simulations for buildings in Malaysia have become possible after the recent construction of a Malaysian TRY (Test Reference Year) based on 21 years of hourly weather data from Subang Meteorological Station. The climatic parameters contained in the TRY are dry bulb temperature, wet...... making TSBI3 a powerful tool for energy analysis and optimisation of buildings. Other applications of the TRY are manifold including energy studies for solar systems and photovoltaic architecture....

  2. WAT Office building, Karlsruhe, Germany

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, H.

    1999-07-01

    In 1994, the WAT (Wasser-und Abfalltechnik GmbH) office building, with various energy-saving features, was erected in Karlsruhe, Germany. The office building, net area 1,500 m{sup 2}, incorporates: facade-integrated solar air collectors preheating the ventilation air; exhaust air extraction through a solar chimney; heat recovery from ventilation air; concrete floors with integrated air ducts and no suspended ceilings. During the design phase, TRNSYS was used to determine the performance of the building and the solar system. (author)

  3. Energy use in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-10-01

    This is the report on Task IB, Familiarization with Additional Data Collection Plans of Annual Survey of BOMA Member and Non-Member Buildings in 20 Cities, of the Energy Use in Office Buildings project. The purpose of the work was to monitor and understand the efforts of the Building Owners and Managers Association International (BOMA) in gathering an energy-use-oriented data base. In order to obtain an improved data base encompassing a broad spectrum of office space and with information suitable for energy analysis in greater detail than is currently available, BOMA undertook a major data-collection effort. Based on a consideration of geographic area, climate, population, and availability of data, BOMA selected twenty cities for data collection. BOMA listed all of the major office space - buildings in excess of 40,000 square feet - in each of the cities. Tax-assessment records, local maps, Chamber of Commerce data, recent industrial-development programs, results of related studies, and local-realtor input were used in an effort to assemble a comprehensive office-building inventory. In order to verify the accuracy and completeness of the building lists, BOMA assembled an Ad-Hoc Review Committee in each city to review the assembled inventory of space. A questionnaire on office-building energy use and building characteristics was developed. In each city BOMA assembled a data collection team operating under the supervision of its regional affiliate to gather the data. For each city a random sample of buildings was selected, and data were gathered. Responses for over 1000 buildings were obtained.

  4. Tropical Zero Energy Office Building

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter; Kristensen, Poul Erik

    2006-01-01

    The new headquarter for Pusat Tenaga Malaysia is designed to be a Zero Emission Office Building (ZEO). A full range of passive and active energy efficiency measures are implemented such that the building will need no more electricity than what can be produced via its own Building Integrated PV...... by daylight, supplemented by electric lighting during very dark and overcast periods. Extensive active energy efficiency measures are implemented in the building in order to reduce the need for electricity to an absolute minimum, without compromising the request for comfortable temperatures and adequate...... lighting. These measures include the use of high efficient lighting controlled according to demand, high efficiency pumps and fans, a high efficiency chiller, and use of energy efficient office equipment. The buildings PV system is connected to the grid. Solar electricity is exported to the grid during...

  5. Tropical Zero Energy Office Building

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter; Kristensen, Poul Erik

    2006-01-01

    The new headquarter for Pusat Tenaga Malaysia is designed to be a Zero Emission Office Building (ZEO). A full range of passive and active energy efficiency measures are implemented such that the building will need no more electricity than what can be produced via its own Building Integrated PV...... by daylight, supplemented by electric lighting during very dark and overcast periods. Extensive active energy efficiency measures are implemented in the building in order to reduce the need for electricity to an absolute minimum, without compromising the request for comfortable temperatures and adequate...... lighting. These measures include the use of high efficient lighting controlled according to demand, high efficiency pumps and fans, a high efficiency chiller, and use of energy efficient office equipment. The buildings PV system is connected to the grid. Solar electricity is exported to the grid during...

  6. Buildability Attributes at Design Phase in Malaysian Building Construction

    Directory of Open Access Journals (Sweden)

    Shaik Hussein Mydin

    2011-07-01

    Full Text Available In Malaysian construction industry, problem is a common occurrence that hinders the project to run smoothly, notably in traditional contracting system where the design and construction process are separated. Previous research revealed that buildability is able to minimise these problems as it link the design and construction. This study outlines the buildability in design stage. Extensive reviews have been carried out on previous researches on buildability concepts, attributes, principles and other areas related to, and contributing to buildability mainly in the design phase. The term ‘buildability attribute’ has been selected in this study to describe those characteristics which directly or indirectly optimize integration of construction knowledge in the building process and balancing the various project and environment constraints to maximize project goals and building performance. Close examinations of available references revealed that altogether there are 19 buildability attributes that can be implemented during the design phase. The results of survey show that Malaysian construction industry practitioners rate the attribute Provide Clear and Complete Design Information (4.56 as the most important and Less Work Below Ground (3.60 as the least important attribute. The client, consultant and contractor share the same opinion regarding the most important and least important attributes, only higher instituiton’s view is slightly different. Out of 19 attributes, 11 attributes have mean values above 4.00, which indicate them as important attributes. This study has successfully measure the importance level of design buildability attributes for building construction in Malaysia.

  7. Job strain among Malaysian office workers of a multinational company.

    Science.gov (United States)

    Maizura, H; Retneswari, M; Moe, H; Hoe, V C W; Bulgiba, A

    2010-05-01

    Information on job strain exposure among Malaysian workers in multinational companies is limited. To investigate the prevalence and factors associated with high job strain among office workers of a multinational company in Malaysia. A cross-sectional study was conducted in November 2007 among 470 eligible workers. Respondents self-administered the Job Content Questionnaire downloaded from the company's intranet. A median-split procedure was applied to create four groups according to the Job Demand-Control Model: active, passive, high and low job strain. Logistic regression models were used to investigate the associations between socio-demographic, occupational and psychosocial factors and high job strain. A total of 356 questionnaires were received (response rate 76%). Twenty-one per cent of respondents were in the high job strain group, 35% were in the passive group, whereas 26% and 17% of workers were in the low strain and active groups, respectively. After controlling for confounders, three factors were found to be associated with high job strain: male workers (adjusted OR 1.94, 95% CI 1.04-3.64), working >48 h per week (adjusted OR 2.51, 95% CI 1.44-4.39) and job insecurity (adjusted OR 1.14, 95% CI 1.02-1.27). One protective factor for high job strain was the scale 'created skill', which is part of skill discretion (adjusted OR 0.70, 95% CI 0.57-0.86). About one in five workers in this study experience high job strain. Work improvement measures include reducing long working hours and job insecurity and giving workers the opportunity to learn, use creativity and develop abilities.

  8. MALAYSIAN WEATHER DATA (TRY) FOR ENERGY SIMULATIONS IN BUILDINGS

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter

    2001-01-01

    Detailed energy simulations for buildings in Malaysia have become possible after the recent construction of a Malaysian TRY (Test Reference Year) based on 21 years of hourly weather data from Subang Meteorological Station. The climatic parameters contained in the TRY are dry bulb temperature, wet...... bulb temperature, absolute humidity, relative humidity, cloud cover, wind speed, wind direction, sunshine hours, global, diffuse and beam solar radiation. The computer program TSBI3 uses the TRY to perform annual energy simulations for buildings hour by hour. The input and output are very detailed...... making TSBI3 a powerful tool for energy analysis and optimisation of buildings. Other applications of the TRY are manifold including energy studies for solar systems and photovoltaic architecture....

  9. Daylight utilisation in office buildings

    DEFF Research Database (Denmark)

    Christoffersen, Jens

    This Ph.D. thesis presents the qualitative and quantitative consequences of full-scale measurements on two daylighting systems, light shelf and Venetian blinds. The systems were investigated to assess their ability to increase daylight penetration and improve daylight distribution in the interior...... the benefits and difficulties regarding use of daylight in office buildings, but it is hoped that the report will provide daylight conscious building design in forthcoming non-domestic buil dings....

  10. FRAGMENTATION ISSUE IN MALAYSIAN INDUSTRIALISED BUILDING SYSTEM (IBS PROJECTS

    Directory of Open Access Journals (Sweden)

    MOHD NASRUN MOHD NAWI

    2014-02-01

    Full Text Available As a developing country, Malaysian is currently driving for implementing a new or modern construction method, the Industrialised Building System (IBS, as an alternative towards enhancing construction performance. Currently, most of the IBS project developments in Malaysia are still conducted by using the traditional construction process approach. This traditional construction process has been widely criticised for its fragmented approach to project delivery and its failure to form effective teams thus created a number of issues such as reworks, time delay, rising costs, lack of communication and coordination, and wastages. This paper through literature review aims to highlight this fragmentation issue and clarify how far it affects the process of IBS implementation. Suggestions on how an integrated approach in design and construction in order to minimise the fragmentation gaps will be concluded.

  11. Daylight utilisation in office buildings

    DEFF Research Database (Denmark)

    Christoffersen, Jens

    This Ph.D. thesis presents the qualitative and quantitative consequences of full-scale measurements on two daylighting systems, light shelf and Venetian blinds. The systems were investigated to assess their ability to increase daylight penetration and improve daylight distribution in the interior...... the benefits and difficulties regarding use of daylight in office buildings, but it is hoped that the report will provide daylight conscious building design in forthcoming non-domestic buil dings......., aiming at increased utili sation of daylight in order to supplement and replace artificial lighting. The visual quality is assessed only by subjective evalua tions of the luminous environment, luminance distributions in the interior and glare problems. This thesis does not pretend to answer or solve all...

  12. Transformation of Malaysian Construction Industry with Building Information Modelling (BIM

    Directory of Open Access Journals (Sweden)

    Latiffi Aryani Ahmad

    2016-01-01

    Full Text Available Building Information Modelling (BIM is a revolution of technology and a process that transformed the way building is planned, designed, analysed, constructed and managed. The revolution of technology and process could increase the quality of construction projects. The knowledge of BIM has been expanding in many countries including Malaysia. Since its inception, the use of BIM has broadened up widely with different purposes. The aims of this paper is to investigate the BIM implementation and uses in Malaysian construction projects. The methodologies adopted for structuring this paper are by using literature review and semi-structured interview with construction players that have experienced and being involved in projects using BIM. The purpose of literature review is to illustrate on the pervious research on the subject matter. Meanwhile, the purpose of interviews is to explore the involvement of construction players, years of experience in projects using BIM and BIM uses in construction projects. The findings revealed that BIM has been implemented in Malaysia since 2007 by various construction players, which are client, architect, C&S engineer, M&E engineer, QS, contractor, facilities manager and BIM consultant. The findings also revealed that BIM is used for project’ visualisation, improving project design, detecting design clashes, quantity take off and operation and maintenance. Further work will be focused on the current practices of construction players in projects using BIM.

  13. Implementation of building information modeling in Malaysian construction industry

    Science.gov (United States)

    Memon, Aftab Hameed; Rahman, Ismail Abdul; Harman, Nur Melly Edora

    2014-10-01

    This study has assessed the implementation level of Building Information Modeling (BIM) in the construction industry of Malaysia. It also investigated several computer software packages facilitating BIM and challenges affecting its implementation. Data collection for this study was carried out using questionnaire survey among the construction practitioners. 95 completed forms of questionnaire received against 150 distributed questionnaire sets from consultant, contractor and client organizations were analyzed statistically. Analysis findings indicated that the level of implementation of BIM in the construction industry of Malaysia is very low. Average index method employed to assess the effectiveness of various software packages of BIM highlighted that Bentley construction, AutoCAD and ArchiCAD are three most popular and effective software packages. Major challenges to BIM implementation are it requires enhanced collaboration, add work to a designer, interoperability and needs enhanced collaboration. For improving the level of implementing BIM in Malaysian industry, it is recommended that a flexible training program of BIM for all practitioners must be created.

  14. Predictors of musculoskeletal discomfort: A cross-cultural comparison between Malaysian and Australian office workers.

    Science.gov (United States)

    Maakip, Ismail; Keegel, Tessa; Oakman, Jodi

    2017-04-01

    Prevalence and predictors associated with musculoskeletal disorders (MSDs) vary considerably between countries. It is plausible that socio-cultural contexts may contribute to these differences. We conducted a cross-sectional survey with 1184 Malaysian and Australian office workers with the aim to examine predictors associated with MSD discomfort. The 6-month period prevalence of self-reported MSD discomfort for Malaysian office workers was 92.8% and 71.2% among Australian workers. In Malaysia, a model regressing level of musculoskeletal discomfort against possible risk factors was significant overall (F [6, 370] = 17.35; p management needs to take into account the work practices and culture of the target population. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  15. Integrated refurbishment planning for sustainable office buildings

    NARCIS (Netherlands)

    Ebbert, T.

    2012-01-01

    Europe's cities are full of office buildings which are technically and visually outdated. Research has demonstrated that more than 60% of German office stock is in acute need for refurbishment. Building planning needs intelligent approaches to façade refurbishment in order to tackle this enormous ma

  16. 77 FR 2296 - Office of Federal High-Performance Green Buildings; the Green Building Advisory Committee...

    Science.gov (United States)

    2012-01-17

    ... ADMINISTRATION Office of Federal High-Performance Green Buildings; the Green Building Advisory Committee... provides the schedule for three teleconference meetings of the Green Building Advisory Committee (the..., Designated Federal Officer, Office of Federal High Performance Green Buildings, Office of...

  17. Potential Improvement of Building Information Modeling (BIM) Implementation in Malaysian Construction Projects

    OpenAIRE

    Latiffi, Aryani,; Mohd, Suzila; Rakiman, Umol,

    2015-01-01

    Part 4: Building Information Modeling (BIM); International audience; Application of building information modeling (BIM), such as preview design clashes and visualize project’s model increase effectiveness in managing construction projects. However, its implementation in Malaysian construction projects is slow in order to see and gain the benefits. Therefore, this paper aims to explore on potential improvement that could increase BIM implementation in construction projects. A literature review...

  18. Advanced Energy Retrofit Guide Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-27

    The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  19. Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.

  20. Night ventilation control strategies in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhaojun; Yi, Lingli; Gao, Fusheng [School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090 (China)

    2009-10-15

    In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)

  1. The Malaysian General Elections of 2013: The Last Attempt at Secular-inclusive Nation-building?

    Directory of Open Access Journals (Sweden)

    Farish A. Noor

    2013-01-01

    Full Text Available This paper looks at the Malaysian General Election campaign of 2013, and focuses primarily on the 1Malaysia project that was foregrounded by the administration of Prime Minister Najib Razak. It compares the 1Malaysia project with other projects aimed at nation-building, such as the Wawasan 2020 project of former Prime Minister Mahathir and the Islam Hadari project of former Prime Minister Badawi; and asks if 1Malaysia was truly an attempt at building a sense of Malaysian nationhood based on universal citizenship regardless of race or religion; and it also considers the response to the 1Malaysia project that came from the opposition parties of the country. Malaysia has experienced a steady process of islamisation that dates back to the Mahathir era, and the question of whether the political domain of Malaysia has been overcome by religious-communitarian markers and values will be raised in the paper as well.

  2. Identifying critical success factors (CSFs) of implementing building information modeling (BIM) in Malaysian construction industry

    Science.gov (United States)

    Yaakob, Mazri; Ali, Wan Nur Athirah Wan; Radzuan, Kamaruddin

    2016-08-01

    Building Information Modeling (BIM) is defined as existing from the earliest concept to demolition and it involves creating and using an intelligent 3D model to inform and communicate project decisions. This research aims to identify the critical success factors (CSFs) of BIM implementation in Malaysian construction industry. A literature review was done to explore previous BIM studies on definitions and history of BIM, construction issues, application of BIM in construction projects as well as benefits of BIM. A series of interviews with multidisciplinary Malaysian construction experts will be conducted purposely for data collection process guided by the research design and methodology approach of this study. The analysis of qualitative data from the process will be combined with criteria identified in the literature review in order to identify the CSFs. Finally, the CSFs of BIM implementation will be validated by further Malaysian industrialists during a workshop. The validated CSFs can be used as a term of reference for both Malaysian practitioners and academics towards measuring BIM effectiveness level in their organizations.

  3. Energy efficiency evaluation of hospital building office

    Science.gov (United States)

    Fitriani, Indah; Sangadji, Senot; Kristiawan, S. A.

    2017-01-01

    One of the strategy employed in building design is reducing energy consumption while maintaining the best comfort zone in building indoor climate. The first step to improve office buildings energy performance by evaluating its existing energy usage using energy consumption intensity (Intensitas Konsumsi Energi, IKE) index. Energy evaluation of office building for hospital dr. Sayidiman at Kabupaten Magetan has been carried out in the initial investigation. The office building is operated with active cooling (air conditioning, AC) and use limited daylighting which consumes 14.61 kWh/m2/month. This IKE value is attributed into a slightly inefficient category. Further investigation was carried out by modeling and simulating thermal energy load and room lighting in every building zone using of Ecotect from Autodesk. Three scenarios of building energy and lighting retrofit have been performed simulating representing energy efficiency using cross ventilation, room openings, and passive cooling. The results of the numerical simulation indicate that the third scenario by employing additional windows, reflector media and skylight exhibit the best result and in accordance with SNI 03-6575-2001 lighting standard. Total thermal load of the existing building which includes fabric gains, indirect solar gains, direct solar gains, ventilation fans, internal gains, inter-zonal gains and cooling load were 162,145.40 kWh. Based on the three scenarios, the thermal load value (kWh) obtained was lowest achieved scenario 2 with the thermal value of 117,539.08 kWh.The final results are interpreted from the total energy emissions evaluated using the Ecotect software, the heating and cooling demand value and specific design of the windows are important factors to determine the energy efficiency of the buildings.

  4. Keith Keesecker Office Building. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Bliege, C.L.

    1981-01-26

    This two story office building has 4000 ft/sup 2/ of space and a 2000 ft/sup 2/ basement. The solar heating system has 936 ft/sup 2/ of flat plate collectors and a phase change storage system. A description of the system operation, the acceptance test plan, as built wiring and piping schematics, and predicted performance data are included. (MHR)

  5. A Carbon Footprint of an Office Building

    Directory of Open Access Journals (Sweden)

    Pellervo Matilainen

    2011-08-01

    Full Text Available Current office buildings are becoming more and more energy efficient. In particular the importance of heating is decreasing, but the share of electricity use is increasing. When the CO2 equivalent emissions are considered, the CO2 emissions from embodied energy make up an important share of the total, indicating that the building materials have a high importance which is often ignored when only the energy efficiency of running the building is considered. This paper studies a new office building in design phase and offers different alternatives to influence building energy consumption, CO2 equivalent emissions from embodied energy from building materials and CO2 equivalent emissions from energy use and how their relationships should be treated. In addition this paper studies how we should weight the primary energy use and the CO2 equivalent emissions of different design options. The results showed that the reduction of energy use reduces both the primary energy use and CO2 equivalent emissions. Especially the reduction of electricity use has a high importance for both primary energy use and CO2 emissions when fossil fuels are used. The lowest CO2 equivalent emissions were achieved when bio-based, renewable energies or nuclear power was used to supply energy for the office building. Evidently then the share of CO2 equivalent emissions from the embodied energy of building materials and products became the dominant source of CO2 equivalent emissions. The lowest primary energy was achieved when bio-based local heating or renewable energies, in addition to district cooling, were used. The highest primary energy was for the nuclear power option.

  6. The energy performance of office buildings throughout their building process

    NARCIS (Netherlands)

    Entrop, Alexis Gerardus; Dewulf, Geert P.M.R.; Wamelink, J.W.F.; Geraedts, R.P.; Volker, L.

    2011-01-01

    Many innovative techniques and policy measures have been introduced to reduce energy consumption. Despite the high ambitions and societal pressures, the adoption rate of energy measures in office buildings is still low. Using adoption theories this paper provides a framework to analyse the adoption

  7. Towards Integrated Team Practice: A Case of Malaysian Industrialised Building System (IBS Construction Projects

    Directory of Open Access Journals (Sweden)

    Mohd Nawi Mohd Nasrun

    2014-01-01

    Full Text Available Problems associated with fragmentation in the traditional construction process, such as isolation of professionals, lack of co-ordination between design and construction, and the sequential manner of its processes, has impacted on construction performance leading to a lack of integration, wastage, low productivity and efficiency. Integrated team practice is perceived as paramount. Unfortunately, there has a limitation of study focus on the dimension of fully integrated team especially for Malaysian Industrialised Building System (IBS projects. Accordingly, this research paper explores and identifies the dimension of fully integrated team from the traditional approach and conduct a validation process for implementing it in Malaysian IBS projects. The research presented uses interviews case study to obtain qualitative data. It was found that the dimension of fully integrated team from the traditional construction process could apply to the Malaysian IBS projects. Suggestions on how an integrated team practice in IBS design and construction process in order to minimise the fragmentation gaps will be concluded.

  8. 77 FR 24494 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2012-04-24

    ... ADMINISTRATION Office of Federal High-Performance Green Buildings; Green Building Advisory Committee... and agenda for the May 9, 2012, meeting of the Green Building Advisory Committee Meeting (the... Sandler, Designated Federal Officer, Office of Federal High-Performance Green Buildings, Office...

  9. Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-04-01

    Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly large fraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

  10. Development of a sustainability assessment tool for office buildings

    OpenAIRE

    Barbosa, José Amarilio; Mateus, Ricardo; Bragança, L.

    2012-01-01

    The few available sustainability assessment tools applicable in Portugal are oriented for residential buildings. Nevertheless, the impacts of office buildings have been rising mainly due to an increase in the energy consumption for cooling and heating. This way, due to the growing environmental impact of office buildings, the development of Build-ing Sustainability Assessment (BSA) tools to assess the sustainability of this type of buildings is necessary and important to guide and to boost th...

  11. Pusat Tenaga Malaysia's Zero Energy Office (ZEO) Building

    DEFF Research Database (Denmark)

    Tang, C.K.; Reimann, Gregers Peter; Kristensen, Poul Erik

    Technical Review of the Zero Energy Office building in Malaysia. The building, which has an energy index of 50 kWh/m2/year, reaches a net annual energy of zero through the use of building integrated photovoltaic panels. For reference, ordinary offices in Malaysia consume 200 - 300 kWh/m2/year...

  12. 78 FR 56703 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2013-09-13

    ... ADMINISTRATION Office of Federal High-Performance Green Buildings; Green Building Advisory Committee..., 2013, meeting of the Green Building Advisory Committee Meeting (the Committee) and the schedule for a... CONTACT: Ken Sandler, Designated Federal Officer, ] Office of Federal High-Performance Green...

  13. Sensory evaluation of the air in 14 office buildings

    DEFF Research Database (Denmark)

    Pejtersen, Jan; Schwab, R.; Mayer, E.

    1999-01-01

    The perceived air quality was assessed in eight mechanically and six naturally ventilated office buildings. On average, 44 offices were investigated in each building. A panel of 11 trained subjects assessed the perceived air quality in the spaces directly in the sensory unit decipol. The average...... perceived air quality in the 14 office buildings ranged from 3.4 to 7.8 decipol. The perceived air quality averaged 4.1 decipol in the mechanically ventilated buildings and 6.0 decipol in the naturally ventilated buildings. Within the buildings there was a large variation in perceived air quality between...... the offices. The results indicate that the occupants' behaviour is important for the pollution load and the air quality in offices....

  14. 78 FR 21368 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2013-04-10

    ... ADMINISTRATION Office of Federal High-Performance Green Buildings; Green Building Advisory Committee... provides the schedule and agenda for the May 1, 2013, meeting of the Green Building Advisory Committee... Green Buildings, Office of Government-wide Policy, General Services Administration, 1275 First Street...

  15. 77 FR 66616 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2012-11-06

    ... ADMINISTRATION Office of Federal High-Performance Green Buildings; Green Building Advisory Committee... provides the schedule and agenda for the November 27, 2012, meeting of the Green Building Advisory... High-Performance Green Buildings, Office of Government-wide Policy, General Services...

  16. BUSINESS STRATEGY OF LARGE CONTRACTORS IN ADOPTING INDUSTRIALISED BUILDING SYSTEM (IBS: THE MALAYSIAN CASE

    Directory of Open Access Journals (Sweden)

    FRANKY AMBON

    2012-12-01

    Full Text Available Industrialised Building System (IBS is the term coined by the government and industry in Malaysia to represent the construction industry and the application of prefabrication method in building construction. The purpose of this exploratory research paper is to highlight business strategy being pursued by large Malaysian contractors in adopting IBS. The paper uses case study as research method. The analysis is based primarily on cross-case analysis and pattern matching technique. The paper observes contractors which involved in IBS are part of larger holding companies in a corporate set-up include design and manufacturing subsidiaries. The companies positioned themselves as one-stop total solution provider for IBS and offer a wider range of services from design, production, and installation to clients. To become competitive and able to create total solution, contractors need to establish cluster and consortium of integrated project team by creating a partnership when and where it is needed. A vendor development programme modelled along the lines of the development of automotive industry should also be established. Future empirical studies should extensively examine these areas, especially the development of business model for contractors. The availability of this model could help to accelerate the uptake of IBS among contractors.

  17. 2013 Building Technologies Office Program Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-11-01

    The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2–4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO’s Emerging Technologies Program, 20 from the Commercial Buildings Integration Program, 6 from the Residential Buildings Integration Program, and 4 from the Building Energy Codes Program. This report summarizes the scores and comments provided by the independent reviewers for each project.

  18. Collaboration Initiative on Green Construction and Sustainability through Industrialized Buildings Systems (IBS in the Malaysian Construction Industry

    Directory of Open Access Journals (Sweden)

    Kamarul Anuar Mohamad Kamar

    2011-05-01

    Full Text Available Malaysian Construction Industry has been urged to use innovative construction technique and to shift from traditional practice of brick and mortar to Industrialized Building System (IBS construction. IBS is defined as a construction technique in which components are manufactured in a controlled environment (on or off site, transported, positioned and assembled into a structure with minimal additional site works. On the other hand, the issues of sustainability and green construction have been duly highlighted in the Construction Industry Master Plan (2005 – 2015 as being of significant importance for the Malaysian construction industry. The Malaysian government is also committed to addressing sustainability issues and meeting its target and obligations in this regard. This paper highlights several aspects of IBS that has the potential of contributing to green construction and sustainability. IBS promotes sustainability from controlled production environment, minimization of waste generation, extensive usage of energy efficient building material, effective logistics and long term economic stability which can contribute to better investment in environment technologies. The Construction Research Institute of Malaysia (CREAM, University of Salford and other research institutes in Malaysia will conduct a collaboration Research and Development (R&D initiative on green construction and sustainability trough IBS implementation. From this paper, the authors hope to receive feedbacks, comments and recommendations to improve research aims, objectives, expected deliverables and research methodology.

  19. Building information modelling (BIM) after ten years: Malaysian construction players’ perception of BIM

    Science.gov (United States)

    Latiffi, A. Ahmad; Brahim, J.; Fathi, M. S.

    2017-08-01

    Building Information Modelling (BIM) concept has expanded widely in many countries for more than a decade with its role of improving current practices in construction projects. However, the understanding of BIM differs among construction players, depending on how construction players utilize the concept in their projects. Therefore, this paper aims to explore the understanding of BIM concept among construction players in the Malaysian construction industry. A literature review on BIM concept and semi-structured interviews with construction players in BIM such as client, civil and structural (C&S) engineer and mechanical and electrical (M&E) engineer, quantity surveyor (QS), contractor, facilities manager and BIM consultant have been conducted in order to achieve this study’s the aim. The results show that the understanding of BIM concept among the construction players is limited to BIM as a process and technology. It is important for the construction players to improve their understanding of BIM as it can be used to enhance performance and productivity of construction projects.

  20. Office Building Occupant's Guide to Indoor Air Quality

    Science.gov (United States)

    ... United States Environmental Protection Agency Search Search Indoor Air Quality (IAQ) Contact Us Share An Office Building Occupants Guide to Indoor Air Quality Indoor Environments Division (6609J) Washington, DC 20460 EPA- ...

  1. Essential Approach of Maintenance Management System of Office Building

    Directory of Open Access Journals (Sweden)

    Masyatul Husna Othman

    2013-09-01

    Full Text Available Buildings will be worn-out, dilapidated and dirty as time goes by; but with good maintenance management we can at least prolong the lifespan of building longer as well as provide the building services and keep the building performance at it ultimate level. The importance of carrying out a systematic and routine maintenance works as part of works to conserve building performance is often neglected due to various factors including due to misunderstanding on the needs of the maintenance works itself and budget allocated. Thus, the purpose of the present study was to evaluating the level of maintenance management and quality of services in office buildings. This study also sought to answer the following question to determine the basic approach of maintenance management system used for office buildings.

  2. Solar shading control strategy for office buildings in cold climate

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth; Heiselberg, Per Kvols; Bryn, Ida;

    2016-01-01

    Highlights •Solar shading control strategy for office buildings in cold climate is developed. •Satisfying energy and indoor environmental performance is confirmed. •Importance of integrated evaluations when selecting shading strategy is illustrated.......Highlights •Solar shading control strategy for office buildings in cold climate is developed. •Satisfying energy and indoor environmental performance is confirmed. •Importance of integrated evaluations when selecting shading strategy is illustrated....

  3. Implementation Framework of Green Building for Malaysian Government Building: KKR2 Study

    Directory of Open Access Journals (Sweden)

    Sharif Shiela

    2016-01-01

    Full Text Available The purpose of this study is to develop the Implementation Framework of Green Building for Government Project. Implementation of Green Building Design is very important in Malaysia to conduct and execute green government project. The research intended to answer the questions about the factors involve in the development of the framework, what is the significant relationships exists between the factors involve in the Implementation Framework and whether there is significant relationship exists between the factors in implementation framework. A total 30 respondent selected between multilevel of project team KKR2 including engineers, assistants engineers, technical assistant, stake holders, contractors and consultants. In conclusion the study answered pertaining questions regarding the factors involve in development of Implementation Framework of Green Building through quantitative research and hypothesis testing.

  4. OFFICE. Passive retrofitting of office buildings to improve their energy performance and indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The main objectives of OFFICE were to investigate the possibilities of applying passive retrofitting techniques in office buildings in order to improve their energy performance and indoor working conditions. The project was divided into the following three subgroups: The Experimental subgroup; The Design and Evaluation subgroup; The Design guidelines subgroup. The main task of the Experimental subgroup was to carry out monitoring campaigns in ten selected office buildings in Europe, in order to collect data regarding their energy performance and current state. The main task of the Design and Evaluation subgroup was to prepare and study detailed retrofitting strategies for office buildings and to quantify the impact of the proposed techniques from an energy and environmental point of view. The main task of the Design guidelines subgroup was to integrate the findings of the present research into a diagnostic assessment methodology for best practice retrofitting of office buildings. The outcome of this task includes the main final products of the project: Case studies presenting high quality examples of representative retrofitted office buildings in various parts of Europe. The studies include a description of the present situation as well as an assessment of the possibilities for energy retrofitting in each case; Rating Methodologies classifying office buildings according to their energy consumption, CO{sub 2} production and indoor thermal and visual comfort; An Atlas describing the technical potential for energy conservation of selected retrofitting scenarios for defined types of office buildings in different climatic zones in Europe. The Atlas, combined with the rating methodology, offer possibilities for the evaluation and assessment of retrofitting actions in existing office buildings; A Handbook describing and evaluating retrofitting solutions for office buildings in Europe. It includes design guidelines, performance criteria and methodologies for best practice

  5. Energy optimization of office buildings; Energioptimering af kontorbyggeri

    Energy Technology Data Exchange (ETDEWEB)

    Wittchen, K.B.; Place Hansen, E.J. de (Statens Byggeforskningsinstitut (SBi), Hoersholm (Denmark)); Radisch, N.H.; Treldal, J. (Ramboell A/S, Koebenhavn (Denmark))

    2011-07-01

    The project analysed two main office building types - high-rises and low-rises - and calculated a number of parameters, using the simulation program BSim. Calculations showed that the overall building design and orientation effect is moderate compared with, for instance, use of daylight control and low-energy lighting, computers, etc. Considerable energy savings can be achieved by use of natural ventilation in the summer, thus only using mechanical ventilation with heat recovery during the day in the winter. Open-plan offices result in a better indoor climate and lower energy consumption than cubicle offices. (LN)

  6. Examination of low energy retrofit measures in European office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kofoed, N.U.

    2000-07-01

    This paper describes the methodology used in the Design and Evaluation Group in the project 'OFFICE - Passive Retrofitting of Office Buildings to Improve their Energy Performance and Indoor Working Conditions' funded by the European Commission under the JOULE III Programme. The objectives of the OFFICE project are to promote passive solar and energy efficient retrofitting measures in terms of energy, indoor environment and economy and based on this develop global retrofitting strategies and design guidelines. Ten European office buildings are included in the project situated respectively in England, France, Greece, Italy, Norway, Denmark, Sweden, Germany and Switzerland. To exemplify the type of results and analysis produced in the project, selected results from the Danish and Greek case study buildings are presented. (au)

  7. Thermal performance of a passive solar office building in Portugal

    OpenAIRE

    Gonçalves, Helder; Silva, António Rocha e; Rodrigues, Carlos

    2008-01-01

    This paper presents the thermal performance of a Passive Solar Office Building in Portugal in winter and summer 2006 and 2007. This Building, called Solar XXI, pretends to be an example of passive design both for heating and cooling. It contains a direct gain system assisted by a solar thermal system for winter conditions. In summer a ground cooling system (buried pipes) is used to cool the building, together with night cooling strategies. It also integrate in the vertical south envelope a Ph...

  8. Investigation of Indoor Climate in a Naturally Ventilated Office Building

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Kalyanova, Olena; Jensen, Rasmus Lund;

    2008-01-01

    A measuring program in a naturally ventilated office building in Copenhagen was carried out to document the indoor climate and ventilation system performance during a year. It included a questionnaire regarding the perceived indoor environmental quality and physical measurements of thermal comfort...... to a combination of poor control of solar shading and a very high local heat load that was above the Danish recommendations for naturally ventilated office buildings. Both measured and perceived indoor air quality in the building was in general very high. The measured air flow rates was relatively high due...... to the need for cooling in the office building, while the level of infiltration was quite low indicating an airtight construction....

  9. Dynamics of airborne fungal populations in a large office building

    Science.gov (United States)

    Burge, H. A.; Pierson, D. L.; Groves, T. O.; Strawn, K. F.; Mishra, S. K.

    2000-01-01

    The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.

  10. Building Technologies Office FY 2017 Budget At-A-Glance

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-03-01

    Buildings and homes use more than 73% of the electrical energy consumed in the United States. They also consume 40% of the nation’s total energy, with an annual energy bill of $430 billion. These energy bills can be cost effectively reduced by 20%–50% or more through various energy-efficient technologies and techniques. The Building Technologies Office (BTO) will continue to develop and demonstrate advanced building efficiency technologies and practices to make buildings in the United States more efficient, affordable, and comfortable.

  11. Building Green: The Adoption Process of LEED- and Energy Star-Rated Office Buildings

    Science.gov (United States)

    Malkani, Arvin P.

    2012-01-01

    There are opportunities for green building technology in office buildings to produce energy savings and cost efficiencies that can produce a positive economic and environmental impact. In order for these opportunities to be realized, however, decision makers must appreciate the value of green building technology. The objective of this research is…

  12. Building Green: The Adoption Process of LEED- and Energy Star-Rated Office Buildings

    Science.gov (United States)

    Malkani, Arvin P.

    2012-01-01

    There are opportunities for green building technology in office buildings to produce energy savings and cost efficiencies that can produce a positive economic and environmental impact. In order for these opportunities to be realized, however, decision makers must appreciate the value of green building technology. The objective of this research is…

  13. 76 FR 65511 - Office of Governmentwide Policy; Office of Federal High-Performance Green Buildings; the Green...

    Science.gov (United States)

    2011-10-21

    ... ADMINISTRATION Office of Governmentwide Policy; Office of Federal High- Performance Green Buildings; the Green... provides the schedule and agenda for the first meeting of the Green Building Advisory Committee Meeting...: Ken Sandler, Designated Federal Official, Office of Federal High-Performance Green Buildings,...

  14. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, Leila; Pejtersen, Jan; Gunnarsen, Lars Bo

    2007-01-01

    Abstract The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration- response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR ¼ 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR ¼ 1.5). No single...

  15. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, L; Pejtersen, J; Gunnarsen, L

    2007-01-01

    UNLABELLED: The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration-response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR = 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR = 1.5). No single...

  16. Prevalence and predictors for musculoskeletal discomfort in Malaysian office workers: Investigating explanatory factors for a developing country.

    Science.gov (United States)

    Maakip, Ismail; Keegel, Tessa; Oakman, Jodi

    2016-03-01

    Musculoskeletal disorders (MSDs) are a major occupational health issue for workers in developed and developing countries, including Malaysia. Most research related to MSDs has been undertaken in developed countries; given the different regulatory and cultural practices it is plausible that contributions of hazard and risk factors may be different. A population of Malaysian public service office workers were surveyed (N = 417, 65.5% response rate) to determine prevalence and associated predictors of MSD discomfort. The 6-month period prevalence of MSD discomfort was 92.8% (95%CI = 90.2-95.2%). Akaike's Information Criterion (AIC) analyses was used to compare a range of models and determine a model of best fit. Contributions associated with MSD discomfort in the final model consisted of physical demands (61%), workload (14%), gender (13%), work-home balance (9%) and psychosocial factors (3%). Factors associated with MSD discomfort were similar in developed and developing countries but the relative contribution of factors was different, providing insight into future development of risk management strategies.

  17. Hybrid Ventilation in New and Retrofitted Office Buildings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    The scope of this annex is to obtain better knowledge of the use of hybrid ventilation technologies. The annex will focus on development of control strategies for hybrid ventilation, on development of methods to predict hybrid ventilation performance in office buildings and on development...

  18. Radiological Laboratory, Utility, Office Building LEED Strategy & Achievement

    Energy Technology Data Exchange (ETDEWEB)

    Seguin, Nicole R. [Los Alamos National Laboratory

    2012-07-18

    Missions that the Radiological Laboratory, utility, Office Building (RLUOB) supports are: (1) Nuclear Materials Handling, Processing, and Fabrication; (2) Stockpile Management; (3) Materials and Manufacturing Technologies; (4) Nonproliferation Programs; (5) Waste Management Activities - Environmental Programs; and (6) Materials Disposition. The key capabilities are actinide analytical chemistry and material characterization.

  19. Solar-Heated and Cooled Office Building--Columbus, Ohio

    Science.gov (United States)

    1982-01-01

    Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

  20. European indoor air quality audit project in 56 office buildings

    NARCIS (Netherlands)

    Bluyssen, P.M.; Oliveira Fernandes, E. de; Groes, L.; Clausen, G.H.; Fanger, F.O.; Valbjorn, O.; Bernhard, C.A.; Roulet, C.A.

    1996-01-01

    A European project started at the end of 1992, in which, in addition to current methods, trained sensory panels were used to investigate office buildings all over Europe. The main aim of this EC-Audit was to develop assessment procedures and guid-ance on ventilation and source control, to help optim

  1. Building Green: The Adoption Process of LEED- and Energy Star-Rated Office Buildings

    Science.gov (United States)

    Malkani, Arvin P.

    There are opportunities for green building technology in office buildings to produce energy savings and cost efficiencies that can produce a positive economic and environmental impact. In order for these opportunities to be realized, however, decision makers must appreciate the value of green building technology. The objective of this research is to better understand the motivations that lead office building professionals to adopt green building technology. By utilizing a validated theory named the Unified Theory of Acceptance and Use of Technology (UTAUT), the investigator analyzes the impact of four predictor variables on the behavioral intention to adopt green building technology. The adapted UTAUT model, called the Green Building Technology Model (GBTM), was found to have a statistically significant correlation with the intention to adopt green building technology. The results provide a model for using the GBTM in green building technology applications. Implications are drawn for the green industry on the whole and for the green office building movement in particular. Industry and government can develop interventions based on the insights learned from this study about the adoption process. These interventions, such as education or awareness campaigns, can help increase the adoption of green building technology, further advancing society's efforts to conserve the natural environment and achieve cost efficiencies.

  2. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, Leila; Pejtersen, Jan; Gunnarsen, Lars Bo

    2007-01-01

    Abstract The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... linear part of the concentration- response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR ¼ 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR ¼ 1.5). No single...... symptoms correlated with the potency of surface dust. The PD was not related to single building factors. The inflammatory PD may be used as an integrated proxy measure of biologically active compounds in dust, reflecting health relevant properties of the dust....

  3. Passive cooling in a low-energy office building

    Energy Technology Data Exchange (ETDEWEB)

    Breesch, H.; Janssens, A. [Buildings and Climatic Control, Department of Architecture and Urban Planning, Ghent University, J. Plateaustraat 22, B-9000 Ghent (Belgium); Bossaer, A. [Cenergie cvba, B-2600 Berchem (Belgium)

    2005-12-01

    In office buildings, the use of passive cooling techniques combined with a reduced cooling load may result in a good thermal summer comfort and therefore save cooling energy consumption. This is shown in the low-energy office building 'SD Worx' in Kortrijk (Belgium), in which natural night ventilation and an earth-to-air heat exchanger are applied. In winter, the supply air is successively heated by the earth-to-air heat exchanger and the regenerative heat exchanger, which recovers the heat from the exhaust air. In summer, the earth-to-air heat exchanger cools the ventilation air by day. In addition, natural night ventilation cools down the exposed structure which has accumulated the heat of the previous day. In this article the overall thermal comfort in the office building is evaluated by means of measuring and simulation results. Measurements of summer 2002 are discussed and compared to simulations with a coupled thermal and ventilation simulation model TRNSYS-COMIS. The simulations are used to estimate the relative importance of the different techniques. The evaluation shows that passive cooling has an important impact on the thermal summer comfort in the building. Furthermore, natural night ventilation appears to be much more effective than an earth-to-air heat exchanger to improve comfort. (author)

  4. DOE standard compliance demonstration program: An office building example

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, S.A.; Keller, J.M.; Wrench, L.E.; Williams, C.J.

    1993-06-01

    The US Department of Energy (DOE) issued interim new building energy standards (10 CFR 435 1989) to achieve maximum energy efficiency in the designs of new buildings. DOE then entered into a project to demonstrate and assess the impact of these standards on the design community. One area of focus was a test to see how a less conventional design-focused building would meet the standards` requirements -- DOE wanted to demonstrate that compliance with energy standards does not mean compromising the architectural intent of a building. This study, which was initiated at Pacific Northwest Laboratory (PNL), illustrated the process by which compliance with the standards can be proven for a highly {open_quotes}design-oriented{close_quotes} office building. The study also assessed the impact of the whole building simulation compliance alternatives on design. This report documents the compliance requirements, gives a description of the sample building chosen for the study, provides general guidance for the compliance process, documents the method of compliance that was undertaken for the sample building, presents the results of the study, and provides a recommendation on how the compliance requirements could be improved to reflect more realistic use types.

  5. Green Facility Management in a Shanghai Office Building : A Case Study of the "Asia Building"

    OpenAIRE

    Yunqing, Liang

    2011-01-01

    This paper aims to explore how well green facility management has performed in Shanghai office building and finds the possible way to improve the situation. Together with two interviews, questionnaire based on benchmarking approach is conducted in a case study of the Asia Building, which lead to the conclusion that green facility management has done a fair work in Asia Building, and suggestions that laws and regulations related to green facility management should be established; governmental ...

  6. Office of Building Technologies evaluation and planning report

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, B.

    1994-06-01

    The US Department of Energy (DOE) Office of Building Technologies (OBT) encourages increased efficiency of energy use in the buildings sector through the conduct of a comprehensive research program, the transfer of research results to industry, and the implementation of DOE`s statutory responsibilities in the buildings area. The planning and direction of these activities require the development and maintenance of database and modeling capability, as well as the conduct of analyses. This report summarizes the results of evaluation and planning activities undertaken on behalf of OBT during the past several years. It provides historical data on energy consumption patterns, prices, and building characteristics used in OBT`s planning processes, and summaries of selected recent OBT analysis activities.

  7. Office of Building Technologies evaluation and planning report

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, B.

    1994-06-01

    The US Department of Energy (DOE) Office of Building Technologies (OBT) encourages increased efficiency of energy use in the buildings sector through the conduct of a comprehensive research program, the transfer of research results to industry, and the implementation of DOE`s statutory responsibilities in the buildings area. The planning and direction of these activities require the development and maintenance of database and modeling capability, as well as the conduct of analyses. This report summarizes the results of evaluation and planning activities undertaken on behalf of OBT during the past several years. It provides historical data on energy consumption patterns, prices, and building characteristics used in OBT`s planning processes, and summaries of selected recent OBT analysis activities.

  8. Energy modeling of two office buildings with data center for green building design

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Yiqun; Yin, Rongxin; Huang, Zhizhong [Institute of Building Performance and Technology, Sino-German College of Applied Sciences, Tongji University, Shanghai 200092 (China)

    2008-07-01

    Energy simulation models are developed with EnergyPlus for two office buildings in a R and D center in Shanghai, China to evaluate the energy cost savings of green building design options compared with the baseline building. As a R and D center of an international IT corporation, there are data centers in the two buildings, which make them different from typical office buildings. The data centers house high energy consuming IT equipments and need 24 h air-conditioning every day all year round. In order to achieve energy cost savings, multiple energy efficiency strategies are employed for design proposed building, encompassing high performance building envelope, lighting system, and HVAC system. Through energy modeling, the design proposed options are compared to an ASHRAE 90.1-2004 compliant budget model to highlight energy cost savings versus ''standard practice'' and show the potential LEED trademark Credit EA1 - Optimize Energy Performance. Meanwhile, they are also compared to China Code model to figure out the energy cost savings versus the most popular practice conforming to China Public Building Energy Saving Design Standard. The whole building energy simulation results show that the yearly energy cost saving of the proposed design will be approximately 27% from China Code building and 21% from ASHRAE budget building, which can achieve 4 points for LEED credit due to energy performance optimization. (author)

  9. 76 FR 35894 - Office of Federal High-Performance Green Buildings; Establishment of the Green Building Advisory...

    Science.gov (United States)

    2011-06-20

    ...] Office of Federal High-Performance Green Buildings; Establishment of the Green Building Advisory...: Notice. SUMMARY: GSA announces the establishment of the Green Building Advisory Committee (the Committee... strategic plans, products and activities of the Office of Federal High-Performance Green Buildings...

  10. Best Practices Guide for High-Performance Indian Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Reshma [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sartor, Dale [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ghatikar, Girish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This document provides best practice guidance and energy- efficiency recommendations for the design, construction, and operation of high-­performance office buildings in India. Through a discussion of learnings from exemplary projects and inputs from experts, it provides recommendations that can potentially help achieve (1) enhanced working environments, (2) economic construction/faster payback, (3) reduced operating costs, and (4) reduced greenhouse gas (GHG) emissions. It also provides ambitious (but achievable) energy performance benchmarks, both as adopted targets during building modeling (design phase) and during measurement and verification (operations phase). These benchmarks have been derived from a set of representative best-in-class office buildings in India. The best practices strategies presented in this guide would ideally help in delivering high-­performance in terms of a triad—of energy efficiency, cost efficiency, and occupant comfort and well-­being. These best practices strategies and metrics should be normalized—that is, corrected to account for building characteristics, diversity of operations, weather, and materials and construction methods.

  11. Application of BIM technology in green scientific research office building

    Science.gov (United States)

    Ni, Xin; Sun, Jianhua; Wang, Bo

    2017-05-01

    BIM technology as a kind of information technology, has been along with the advancement of building industrialization application in domestic building industry gradually. Based on reasonable construction BIM model, using BIM technology platform, through collaborative design tools can effectively improve the design efficiency and design quality. Vanda northwest engineering design and research institute co., LTD., the scientific research office building project in combination with the practical situation of engineering using BIM technology, formed in the BIM model combined with related information according to the energy energy model (BEM) and the application of BIM technology in construction management stage made exploration, and the direct experience and the achievements gained by the architectural design part made a summary.

  12. Building-related risk factors and work-related lower respiratory symptoms in 80 office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Naco, G.M.; Wilcox, T.G.; Sieber, W.K.

    2002-01-01

    We assessed building-related risk factors for lower respiratory symptoms in office workers. The National Institute for Occupational Safety and Health in 1993 collected data during indoor environmental health investigations of workplaces. We used multivariate logistic regression analyses to assess relationships between lower respiratory symptoms in office workers and risk factors plausibly related to microbiologic contamination. Among 2,435 occupants in 80 office buildings, frequent, work-related multiple lower respiratory symptoms were strongly associated, in multivariate models, with two risk factors for microbiologic contamination: poor pan drainage under cooling coils and debris in outside air intake. Associations tended to be stronger among those with a history of physician-diagnosed asthma. These findings suggest that adverse lower respiratory health effects from indoor work environments, although unusual, may occur in relation to poorly designed or maintained ventilation systems, particularly among previously diagnosed asthmatics. These findings require confirmation in more representative buildings.

  13. The thermal environment and occupant perceptions in European office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J.L. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2002-02-01

    The results from a large field study of thermal comfort in European office buildings are reported. Environmental conditions and occupant perceptions were collected over fourteen months from twenty-six different office buildings located in France, Greece, Portugal, Sweden and the UK. This thesis focuses on the thermal measurements and occupant perceptions; however, some of the additional variables with strong connections to thermal sensation are also examined. A summary of human comfort is presented to help place this thesis in appropriate context. The summary presents thermal comfort issues within a broad framework of environmental comfort including physical, physiological, behavioural, psychological and other variables. A more narrowly focused overview of current thermal comfort research is also included. The work attempts to show relationships and produce useful information from the data set by using rather simple statistics and graphical methods. The objective is to quite literally use the data set to illustrate the actual thermal conditions in European office buildings and the occupant perceptions of those conditions. The data are examined in some detail with key relationships identified and explored. Significant differences between countries, both for the physical conditions and the perceptions of those conditions are identified. In addition, the variation over the course of the year for each country is explored. The variations occur in complex ways, which make simple, all encompassing explanations impossible. The nature and size of the variations make the application of simple Europe wide models of thermal comfort questionable. It appears that individuals in different European countries have different expectations for their indoor office thermal environment. This data set will be further explored in a more complete study, which will examine the other measured variables.

  14. Pollution prevention opportunity assessment for Building 922 solid office waste

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, N.M. [Sandia National Labs., Livermore, CA (United States). Environmental Protection Dept.

    1995-01-01

    Building 922 houses all of SNL/California`s ES and H Departments: Health Protection, Environmental Protection, Safety, and Environmental Operations. It covers approximately 10,000 square feet and houses about 80 people. The office personnel generate nonhazardous solid office wastes in their daily activities. To determine the types and amounts of waste generated, a special PPOA sorting team sorted all of the trash collected from the building for a period of one-week (including paper and aluminum cans in the recycling bins). The team sorted the trash into major categories: paper, plastic, metals, glass, wet garbage, rest room waste, and miscellaneous materials. They then sorted it into subcategories within each major category. Rest room waste was collected but not sorted. The waste in each category was weighed separately. The total amount of trash collected during the week was approximately 168.8 kg (371.4 lbs). The results of this PPOA indicate that SNL/California is minimizing most nonhazardous office waste and reductions planned for the near future will add significantly to the minimization efforts.

  15. Assessment Framework of Building Facade in Optimizing Indoor Thermal Comfort of Green Building Index (GBI Certified Office Building

    Directory of Open Access Journals (Sweden)

    Abdul Tharim Asniza Hamimi

    2016-01-01

    Full Text Available During the past decade, the construction industry has seen a new trend in the development of “green” or “sustainable” construction concept around the world with vast support from prominent organization, together with the introduction of sustainable building codes. The establishment of green building certification systems worldwide is seen as one of the most efforts in the emerging green building movement. In order to support the development of the “green” and “sustainable” concept in Malaysia, Green Building Index (GBI was launched by the government on 21 May 2009 that created to promote sustainability in the built environment and raise awareness of environmental issues. However, the construction industry seems to have focused only on findings the “right mechanism” for an environmentally sustainable “final result” in order for the building to be certified as green with the lacking of continuous assessment on the building performance after the certifications. This study is purposely conducted to investigate the performance of various rated Green Building Index (GBI Non-Residential New Construction office buildings and the influence on Indoor Thermal Comfort (ITC of the selected buildings. The aim is to develop an assessment framework for optimum green building architectural façade to be used for office buildings in Malaysia as well as to analyse the occupants’ perception, satisfaction and performance in the selected Green Building Index (GBI rated office indoor environment. This research is still in its infancy; therefore the paper is focused on research aims, research scope and methodology, and expected deliverables for the proposed research.

  16. 77 FR 43084 - Office of Federal High-Performance Green Buildings; Federal Buildings Personnel Training Act...

    Science.gov (United States)

    2012-07-23

    ... available for download from the Office of Federal High-Performance Green Building Web site Library at-- http://www.gsa.gov/portal/content/117699 . The Facilities Management Institute, FMI.innovations.gov....innovations.gov (available 08/01/ 2012), an open site where the public, Federal agencies,...

  17. Relationship between Quality of Building Maintenance System and Occupant Satisfaction for Office Buildings

    Directory of Open Access Journals (Sweden)

    Hamid A.H.A

    2014-03-01

    Full Text Available Buildings will be weary, decaying and dirty as time goes by; but with highquality maintenance management we can prolong the life-span of building, provide building services and keep the building performance at its ultimate level. The importance of carrying out a systematic and routine maintenance is to conserve building performance. However, this task is often neglected due to various factors including misunderstanding the needs of the maintenance works and lack of budget allocation. This paper highlights the current practice of maintenance management that are being implemented in 6 office buildings located in Kuala Lumpur, Johor, Kedah and Pulau Pinang. Using the responses of questionnaire answered by 150 respondents employed from these selected offices, personal interviews and visual inspection the following findings were made: the occupants were satisfied with the maintenance management of their buildings elements and the delivery characteristics of maintenance works. Visual inspection however showed that some elements are not in a good condition. In conclusion, some recommendations are made to improve the existing system including the establishment of a maintenance plan, selection of experienced contractors and the provision of a service desk.

  18. Development of a methodology for selecting office building upgrading solutions based on a test survey in European buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wittchen, K.B.; Brandt, E. [Danish Building and Urban Research, Horsholm (Denmark)

    2001-07-01

    The potential for using the TOBUS methodology to select office building upgrading solutions have been investigated during field tests in 15 European office buildings in 5 European countries. The 15 office buildings represent a variety of building traditions, architectural designs, construction periods and energy and indoor performance. The buildings were audited following the TOBUS methodology developed within the project. The results of the test surveys were primarily used to improve the TOBUS methodology and secondly to suggest general upgrading solutions and energy retrofit measures for the surveyed buildings. This paper describes the development of the TOBUS methodology based on the 15 test surveys. (author)

  19. Building envelope influence on the annual energy performance in office buildings

    Directory of Open Access Journals (Sweden)

    Harmati Norbert L.

    2016-01-01

    Full Text Available The objective of the research is to determine the quantitative influence of building envelope on the annual heating and cooling energy demand in office buildings demonstrated on a reference office-tower building located in Novi Sad, Serbia. The investigation intended to find preferable and applicable solutions for energy performance improvement in currently inefficient office buildings. A comparative and evaluative analysis was performed among the heating energy expenses and simulated values from the multi-zone model designed in EnergyPlus engine. The research determines an improved window to wall ratio using dynamic daylight simulation and presents the influence of glazing parameters (U-value, Solar heat gain coefficient - SHGC on the annual energy performance. Findings presented window to wall ratio reduction down to 30% and point out the significance of the SHGC parameter on the overall energy performance of buildings with high internal loads. The calculation of the air-ventilation energy demand according to EN 15251 is included respectively. Results offer effective methods for energy performance improvement in temperate climate conditions.

  20. Factsheet on Energy Neutral School Buildings and Office Buildings; Infoblad Energieneutrale scholen en kantoren

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-15

    A brief overview is given of all aspects of energy-neutral building and renovating school and office buildings. Besides technique, also attention is given to process, financing, management and maintenance. This factsheet is part of a series of three factsheets on energy neutral construction of houses and buildings. The other two are: 'Factsheet on Energy Neutral Building : Definition and ambition' and 'Factsheet on Energy Neutral Building' [Dutch] Een kort overzicht wordt gegeven van alle aspecten van energieneutraal bouwen en renoveren van woningen. Naast techniek komen ook proces, financiering en beheer en onderhoud aan de orde. Dit Infoblad maakt deel uit van een serie van drie Infobladen over energieneutraal bouwen voor woningen en gebouwen. De andere twee zijn: 'Infoblad Energieneutraal bouwen: definitie en ambitie' en 'Infoblad Energieneutrale Woningbouw'.

  1. Technical Support Document: 50% Energy Savings for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  2. Energy Savings Modeling of Standard Commercial Building Re-tuning Measures: Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas; Katipamula, Srinivas; Wang, Weimin; Huang, Yunzhi; Liu, Guopeng

    2012-06-01

    Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS's capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This report investigates the energy savings potential of several common HVAC system retuning measures on a typical large office building prototype model, using the Department of Energy's building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated - each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All of these measures and combinations were simulated in 16 cities representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy

  3. Computer simulation for better design and operation of large office building air-conditioning

    NARCIS (Netherlands)

    Lain, M.; Hensen, J.; Zmrhal, V.

    2009-01-01

    The paper deals with the use of computer simulations both for the design support of a new buildings and HVAC system development and for the optimisation of the system control strategy in the building. This is presented on a real office building in Prague. For a new large bank head office in Prague,

  4. Building Maintenance Management in a Malaysian University Campus: A Case Study

    Directory of Open Access Journals (Sweden)

    Olanrewaju Abdul Lateef

    2010-07-01

    Full Text Available University buildings require maintenance in order to create a conducive environment that supports and stimulates learning, teaching, innovation, and research. The prime objective of maintenance is to ensure, as far as practicable, the continued peak performance of the building throughout its design life. This paper seeks to report the maintenance management system of a university institution in Malaysia. Primary data was gathered through the analysis of a case study. The objectives of the case study are to identify, describe and assess the maintenance management system used by the university. The major conclusion drawn from the case study was that although university building maintenance practices are corrective and cyclical there is a lack of a comprehensive maintenance management framework that guides the decision-making processes. The case study also revealed irregularities in the university’s maintenance management system.

  5. Intelligent Facades in Buildings Facades of local Office Buildings - Case Study

    Directory of Open Access Journals (Sweden)

    Al-Qaraghuli Anwar Subhi

    2016-01-01

    Full Text Available In order to meet the functional performance and requirements on the environmental, ecological, social and aesthetical aspects, it became a necessity to develop another options of building that would be more efficient in the provision of those requirements, so a new generation have appeared called “Smart Buildings” or “Intelligent Buildings” with their sophisticated parts and various details, one of those essential parts is the “Intelligent Façade” for it’s being the essential and primary defensive line for the building against the environmental and climatic variations.This research focused on presenting the most clearly and comprehensive perception of the intelligent façades, in a manner that serves the ability of the designer to apply them in his designs or while developing an existing façades in local (Iraqi office buildings.To achieve such goal, it has been a necessity to adopt a descriptive and analytical Method for the previous knowledge and take a sequential researching steps, the first step was to build a comprehensive theoretical framework by defining the intelligent façade. Down to abstracting three main vocabularies of the theoretical framework represented by: integrated intelligent façade design, intelligent façade techniques, and effective response.The next research steps focused on applying the vocabularies of the theoretical framework on the elected local office buildings that have been adopted the matter of intelligent façades in one of their forms, and then analyze/discuss the results of the applicable study, to be able to draw the final conclusions, and by this the research presented a determined recommendations.

  6. Energy-Efficient Office Buildings at High Latitudes

    Energy Technology Data Exchange (ETDEWEB)

    Lerum, V.

    1996-12-31

    This doctoral thesis describes a method for energy efficient office building design at high latitudes and cold climates. The method combines daylighting, passive solar heating, solar protection, and ventilative cooling. The thesis focuses on optimal design of an equatorial-facing fenestration system. A spreadsheet framework linking existing simplified methods is used. The daylight analysis uses location specific data on frequency distribution of diffuse daylight on vertical surfaces to estimate energy savings from optimal window and room configurations in combination with a daylight-responsive electric lighting system. The passive solar heating analysis is a generalization of a solar load ratio method adapted to cold climates by combining it with the Norwegian standard NS3031 for winter months when the solar savings fraction is negative. The emphasis is on very high computational efficiency to permit rapid and comprehensive examination of a large number of options early in design. The procedure is illustrated for a location in Trondheim, Norway, testing the relative significance of various design improvement options relative to a base case. The method is also tested for two other locations in Norway, at latitudes 58 and 70 degrees North. The band of latitudes between these limits covers cities in Alaska, Canada, Greenland, Iceland, Scandinavia, Finland, Russia, and Northern Japan. A comprehensive study of the ``whole building approach`` shows the impact of integrated daylighting and low-energy design strategies. In general, consumption of lighting electricity may be reduced by 50-80%, even at extremely high latitudes. The reduced internal heat from electric lights is replaced by passive solar heating. 113 refs., 85 figs., 25 tabs.

  7. Test of BREEAM, DGNB, HQE and LEED on two Danish office buildings

    DEFF Research Database (Denmark)

    Birgisdottir, Harpa; Hansen, Klaus

    2011-01-01

    A Green Building Council has been established aiming to introduce, adapt and manage an international certification scheme for sustainable buildings in Denmark. It was therefore decided to test BREEAM, DGNB, HQE and LEED on two new Danish office buildings to gain knowledge of how well the buildings...

  8. Physicochemical treatment of office and public buildings greywater.

    Science.gov (United States)

    Friedler, Eran; Alfiya, Yuval

    2010-01-01

    The current study analyses the performance of deep sand filtration of greywater from an office building and the performance of a combined physicochemical process comprising of coagulation, sedimentation and filtration. Raw greywater quality exhibited very high variability with average turbidity of 35 NTU, and TSS, COD(t), and BOD of 45, 240, 75 mg/l respectively. The stand-alone filter removed 50 and 70% of the turbidity and TSS, but failed to remove COD and BOD. Quality of the produced effluent was too low to allow any reuse. Clogging rate of the filter was high and under hydraulic loading of 3-4 m(3)/(m(2) h) the filtration cycle had to be terminated after 5-8 h. Clogging occurred mainly on the upper layer, indicating the dominance of "cake" filtration mechanism. Addition of coagulation and sedimentation prior to sedimentation dramatically improved effluent quality, reaching overall removal efficiencies of 92, 94, 65 and 57% of turbidity, TSS COD(t) and BOD respectively. The filtration cycle could be prolonged to 20 h. The effluent produced was of much better quality, yet, it has to be further treated (either biological treatment or membrane filtration). Most of the removal occurred in the coagulation-sedimentation step, while the filter acted as a polishing unit.

  9. Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Lane, Michael D.; Rosenberg, Michael I.; Liu, Bing

    2009-09-01

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Medium Offices (AEDG-MO or the Guide), a design guidance document which intends to provide recommendations for achieving 50% energy savings in medium office buildings that just meet the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  10. Model estimates of the contributions of environmental tobacco smoke to volatile organic compound exposures in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.; Gadgil, A.; Hodgson, A.T.

    1990-01-01

    Volatile organic compounds (VOC) in office buildings originate from multiple sources, such as outdoor air, building materials, occupants, office supplies, and office equipment. Many of the VOC found in office buildings are also present in environmental tobacco smoke (ETS), e.g., benzene, toluene, formaldehyde. Measurements made to date in Office buildings have been interpreted by some to imply that the contributions to ETS to VOC exposures in office buildings are small. Four different ventilation-infiltration scenarios were modeled for a typical office building. The purpose of this investigation was to provide first-order estimate of the range of contributions of ETS to VOC contributions in office buildings under various ventilation conditions through the use of a mass-balance model and to evaluate the significance of such contributions relative to the VOC concentration measured in office buildings. 25 refs., 1 fig., 4 tabs.

  11. Post-occupancy evaluation of office buildings in a Johannesburg ...

    African Journals Online (AJOL)

    building performance and similar future buildings can be improved upon in terms .... in the workplace if lighting requirements are not met (De Carli & De. Giuli, 2009: .... productivity, because employees will be motivated to report to work every ...

  12. Office Building, Roskilde, Denmark. Parkvænget 25, 4000 Roskilde

    DEFF Research Database (Denmark)

    Rose, Jørgen; Thomsen, Kirsten Engelund

    Built in 1968 the office building was a typical precast concrete building with a very limited level of insulation. In 1991 the building envelope was renovated and insulation was added to the wall (175 mm) and windows were replaced with traditional double-glazed windows. The main objective...

  13. Energy consumption in office buildings. Trends and drivers; Energibruk i kontorbygg. Trender og drivere

    Energy Technology Data Exchange (ETDEWEB)

    Langseth, Benedicte

    2013-02-01

    This report focuses on the energy usage of Norwegian office buildings. Historic data on the subject is limited, so qualitative input is gathered through interviews with property owners and contractors for energy solutions. We have looked at what affects the total area of office buildings in Norway, and realized that it more or less follows the inland gross domestic product. The report also includes cross-sectional analyses from various data sources to find what affects the specific energy usage of office buildings. The actual measured consumption deviates from estimated consumption, especially in newer buildings and especially within ventilation and cooling. Additionally, a model has been developed for projective purposes. It is well suited to test the effect of various input parameters and assumptions on the total area of office buildings and their energy consumption. Though as of yet the quality of data is not good enough to make a profound and credible estimate of total energy usage.(eb)

  14. Sensitivity Analysis Applied in Design of Low Energy Office Building

    DEFF Research Database (Denmark)

    Heiselberg, Per; Brohus, Henrik

    2008-01-01

    Building performance can be expressed by different indicators as primary energy use, environmental load and/or the indoor environmental quality and a building performance simulation can provide the decision maker with a quantitative measure of the extent to which an integrated design solution...... satisfies the design requirements and objectives. In the design of sustainable Buildings it is beneficial to identify the most important design parameters in order to develop more efficiently alternative design solutions or reach optimized design solutions. A sensitivity analysis makes it possible...... to identify the most important parameters in relation to building performance and to focus design and optimization of sustainable buildings on these fewer, but most important parameters. The sensitivity analyses will typically be performed at a reasonably early stage of the building design process, where...

  15. Pamplin program helps build leadership skills among police officers

    OpenAIRE

    Ho, Sookhan

    2010-01-01

    Twenty-nine law enforcement officers from across Virginia will be graduating on Sept. 23 from a Pamplin College of Business program on leadership skills, developed in partnership with the Virginia Police Chiefs Foundation.

  16. Assessment of energy and natural resources conservation in office buildings using TOBUS

    Energy Technology Data Exchange (ETDEWEB)

    Balaras, C.A.; Droutsa, K.; Argiriou, A.A. [Group Energy Conservation, Institute for Environmental Research and Sustainable Development, National Observatory of Athens, Palaia Penteli, Hellas (Greece); Wittchen, K.B. [Danish Building Research Institute, Horsholm (Denmark)

    2001-07-01

    The potential for optimum energy use and conservation of natural resources in representative southern and northern European office buildings is evaluated using the new European TOBUS methodology and software for office building refurbishment. Various scenarios are being accessed for energy and water conservation in office buildings. The proposed retrofit actions focus in the areas of space heating and cooling, artificial and natural lighting, service hot water, office equipment, elevators and sanitary water. The resulting conservation and related costs are taken into account in order to help the auditor classify the retrofit actions for an audited building. The TOBUS methodology and tools have been implemented to study four Hellenic office buildings and two from Denmark in order to demonstrate the applicability of the overall approach. Energy conservation in Hellenic and Danish buildings range for space heating from 5 to 71 and 0.5 to 6%, for space cooling from 1 to 38 and 4 to 20%, for artificial lighting from 40 to 53 and 26 to 62%, for office equipment from 13 to 62 and 13 to 87% and for elevators at 35 and 23%, respectively. Sanitary water conservation can reach 74% in all audited buildings. (author)

  17. Emergency Management Offices, government building attribute, Published in 2006, Washoe County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Emergency Management Offices dataset, was produced all or in part from Published Reports/Deeds information as of 2006. It is described as 'government building...

  18. INDOOR AIR QUALITY AND PREVALENCE OF SICK BUILDING SYNDROME AMONG OFFICE WORKERS IN TWO DIFFERENT OFFICES IN SELANGOR

    Directory of Open Access Journals (Sweden)

    Mohd Ezman Zamani

    2013-01-01

    Full Text Available This study was done to investigate the relationship between Indoor Air Quality (IAQ and prevalence of Sick Building Syndrome (SBS in two different offices (old and new in Selangor. Hundred and seventy workers were selected consist of 85 office workers for each building. Questionnaire based on Indoor Air Quality and Work Symptoms Survey, NIOSH, Indoor Environmental Quality Survey, 1991 was used to record prevalence of SBS. Measurement of indoor air quality was performed using instruments recommended by IAQ Code of Practice, Department of Occupational Safety and Health, Malaysia. IAQ supplied air was significantly higher in new building with the median 22.49 cfm/person while 15.79 cfm/person in old building (z = -6.23, p2 = 30.6, p2 (z = -4.62, p10 (z = -2.11, p2.5 (z = -2.35, p2 (OR = 3.56, 95% CI = 1.327-9.548; CO (OR = 4.95, 95% CI = 1.740-14.127; TVOC (OR = 4.71, 95% CI = 1.571-14.151; PM10 (OR = 6.23, 95% CI = 2.278-17.065 and PM2.5 (OR = 4.18, 95% CI = 1.564-11.199, while in the new building, the prevalence of SBS showed significant association with an indoor air pollutant namely UFP (OR = 6.53, 95% CI = 1.757-24.327. After controlling the cofounders; age, medical condition, smoking and having pet at home, the results showed that CO2, CO, TVOC, PM10, PM2.5 influenced SBS in old building while UFP influenced SBS in the new building. This study suggested that when there was an increase in the ventilation rates per person in office building, it would significantly reduced prevalence of SBS, even though both buildings meet the existing ASHRAE ventilation standards for office building. Reduction in prevalence of SBS would depend on the increase in ventilation rates, ventilation effectiveness and reduction in indoor air pollutants that can cause SBS.

  19. Towards a new procedure for identifying causes of health and comfort problems in office buildings

    NARCIS (Netherlands)

    Bluyssen, P.M.; Fossati, S.; Mandin, C.; Cattaneo, A.; Carrer, P.

    2012-01-01

    In the European project OFFICAIR a procedure has been prepared for the inventory and identification of associations between possible characteristics of European modern offices (building, sources and events) and health and comfort of office workers, via a questionnaire and a checklist including envir

  20. Effect of renovating an office building on occupants' comfort and health

    DEFF Research Database (Denmark)

    Pejtersen, Jan; Brohus, H.; Hyldgaard, C. E.

    2001-01-01

    . Before the floor material was installed in the office building, a full-scale exposure experiment was performed in the laboratory. The new ventilation strategy and renovation of the HVAC system were selected on the basis of laboratory experiments on a full-scale mock-up of a cellular office. The severity...

  1. Environmental Conditions and Occupant Perceptions in European Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J.L. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2003-03-01

    This is a preliminary report regarding a portion of the environmental conditions and occupant comfort perceptions from a five nation, 26 building European field data collection effort. Approximately 1,000 participants were involved in this project which included twelve monthly visits to each building. Climate, building and cultural variation will be illustrated for the five countries involved - France, Greece, Portugal, Sweden and the United Kingdom (UK). Each country used identical instrumentation; questionnaires and experimental protocols imbedded in a custom hardware/software system. The comfort survey was based on the ASHRAE model. The physical measurements included air temperature, globe temperature, relative humidity, air movement, CO{sub 2}, light, and sound levels. Where possible, connections and explanations between variables are made. Potential energy and policy ramifications are illustrated. (The publication includes two reports from EU JOULE III projects JOE3CT970066 'Smart controls and thermal comfort project)

  2. Economic feasibility of maximising daylighting of a standard office building with efficient electric lighting

    DEFF Research Database (Denmark)

    Fontoynont, Marc; Ramananarivo, Karine; Soreze, Thierry Silvio Claude

    2016-01-01

    This paper investigates the cost of developing various daylighting strategies for a standard office building in relation to their ability to reduce electric lighting consumption. The reference building design for this study corresponds to a typical configuration that minimises the construction co...

  3. Façade system for existing office buildings in Copenhagen

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Michael

    This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements...

  4. Office Building, Roskilde, Denmark. Parkvænget 25, 4000 Roskilde

    DEFF Research Database (Denmark)

    Rose, Jørgen; Thomsen, Kirsten Engelund

    Built in 1968 the office building was a typical precast concrete building with a very limited level of insulation. In 1991 the building envelope was renovated and insulation was added to the wall (175 mm) and windows were replaced with traditional double-glazed windows. The main objective...... of the renovation was to reduce the overall energy consumption of the building while also improving the indoor climate. This was achieved by adding insulation to the facade, replacing existing windows, improving air tightness of the building envelope, replacing the ventilation system and adding photovoltaic cells...

  5. Comfort of workers in office buildings: The European HOPE project

    NARCIS (Netherlands)

    Bluyssen, P.M.; Aries, M.; Dommelen, P. van

    2011-01-01

    Previous studies have shown that building, social and personal factors can influence one's perceived health and comfort. The aim of the underlying study was to get a better understanding of the relationships between these factors and perceived comfort. Self-administered questionnaires from 5732 resp

  6. Occupant satisfaction with the acoustical environment : green office buildings before and after treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, M. [British Columbia Univ., Vancouver, BC (Canada). School of Occupational and Environmental Hygiene, Acoustics and Noise Research Group

    2009-07-01

    Sustainable architecture is meant to preserve the environment and conserve natural resources, as well as provide an environment for the occupants that promotes wellbeing and productivity. Occupants generally claim that the acoustical environment is the least satisfactory aspect of green office buildings. They are dissatisfied with excessive noise and poor speech privacy. This paper reported on the results of 2 studies of the acoustical environments in green office buildings before and after acoustical-control measures were installed. Acoustical quality was evaluated by occupant-satisfaction surveys and acoustical-parameter measurements. The first study, which involved 6 green office buildings, showed that buildings designed to obtain LEED ratings are unlikely to have satisfactory acoustical environments. A naturally-ventilated, green university building with a poor acoustical environment was examined in the second study. The results of this study suggest that improving acoustical environments in green buildings requires good acoustical design, with input from an acoustical specialist from the beginning of the design process. The design should consider site selection and building orientation; external envelope and penetrations in it; building layout and internal partitions; HVAC systems; appropriate dimensioning of spaces; and the amount and location of sound absorbing treatments. The study also showed that a building's energy efficiency, lighting, ventilation, air-quality and acoustics are interconnected, and that no aspect can be successfully designed in isolation. It was concluded that optimized engineering-control measures can improve poor acoustical environments. 11 refs., 1 tab., 1 fig.

  7. Technical Support Document: Development of the Advanced Energy Design Guide for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jarnagin, Ronald E.; Liu, Bing; Winiarski, David W.; McBride, Merle F.; Suharli, L.; Walden, D.

    2006-11-30

    This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for Small Office Buildings (AEDG-SO), a design guidance document intended to provide recommendations for achieving 30% energy savings in small office buildings over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The AEDG-SO is the first in a series of guides being developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA), the New Buildings Institute (NBI), and the U.S. Department of Energy (DOE). Each of the guides in the AEDG series will provide recommendations and user-friendly design assistance to designers, developers and owners of small commercial buildings that will encourage steady progress towards net-zero energy buildings. The guides will provide prescriptive recommendation packages that are capable of reaching the energy savings target for each climate zone in order to ease the burden of the design and construction of energy-efficient small commercial buildings The AEDG-SO was developed by an ASHRAE Special Project committee (SP-102) made up of representatives of each of the partner organizations in eight months. This TSD describes the charge given to the committee in developing the office guide and outlines the schedule of the development effort. The project committee developed two prototype office buildings (5,000 ft2 frame building and 20,000 ft2 two-story mass building) to represent the class of small office buildings and performed an energy simulation scoping study to determine the preliminary levels of efficiency necessary to meet the energy savings target. The simulation approach used by the project committee is documented in this TSD along with

  8. On Variations of Space-heating Energy Use in Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Hung-Wen; Hong, Tianzhen

    2013-05-01

    Space heating is the largest energy end use, consuming more than 7 quintillion joules of site energy annually in the U.S. building sector. A few recent studies showed discrepancies in simulated space-heating energy use among different building energy modeling programs, and the simulated results are suspected to be underpredicting reality. While various uncertainties are associated with building simulations, especially when simulations are performed by different modelers using different simulation programs for buildings with different configurations, it is crucial to identify and evaluate key driving factors to space-heating energy use in order to support the design and operation of low-energy buildings. In this study, 10 design and operation parameters for space-heating systems of two prototypical office buildings in each of three U.S. heating climates are identified and evaluated, using building simulations with EnergyPlus, to determine the most influential parameters and their impacts on variations of space-heating energy use. The influence of annual weather change on space-heating energy is also investigated using 30-year actual weather data. The simulated space-heating energy use is further benchmarked against those from similar actual office buildings in two U.S. commercial-building databases to better understand the discrepancies between simulated and actual energy use. In summary, variations of both the simulated and actual space-heating energy use of office buildings in all three heating climates can be very large. However these variations are mostly driven by a few influential parameters related to building design and operation. The findings provide insights for building designers, owners, operators, and energy policy makers to make better decisions on energy-efficiency technologies to reduce space-heating energy use for both new and existing buildings.

  9. Perceived air quality and sensory pollution loads in six Danish office buildings

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Krupicz, P.; Szczecinski, A.

    2002-01-01

    Perceived air quality and sensory pollution loads were measured in 6 office buildings with mechanical ventilation without recirculation, in each buildings in 6 representative non-smoking medium-sized and small offices with mixing ventilation. An untrained panel of 43 subjects assessed the air...... quality on a normal weekday when the building was occupied, and on a weekend without occupants in the building. On both occasions the ventilation system was in operation as on a normal working day. Outdoor air supply rate, air temperature, relative humidity, concentration of carbon dioxide and ultrafine...... particles were measured. The percentage of persons dissatisfied with air quality ranged from 3 to 30%, decreasing with increasing outdoor air supply rate from 1 to 4 L/(sxm2floor). Total sensory pollution loads ranged from 0.08 to 0.37 olf/m2floor in occupied buildings and from 0.04 to 0.27 olf/m2floor...

  10. SMALL OFFICE BUILDING ENTERPRISE: CRITERIA FOR EFFICIENCY AND COMPETITIVENESS

    Directory of Open Access Journals (Sweden)

    E. V. Folomeev

    2011-01-01

    Full Text Available Main efficiency and competitiveness assessment criteria applicable to small construction organizations operating under market conditions are minimization of reduced costs and maximal conformity with quality requirements to building and structures under construction. Small enterprisefinance organization principles are as follows: independence, self-financing, responsibility for the company’s financial and economic activity results and control thereof. A method of investment option efficiency assessment with due account of construction project specifics is proposed. It is recommended to develop and use strategic cards to provide for balanced enterprise development.

  11. Space heating for office building at Glenwood Springs, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Garing, K.L.; Coury, G.E.

    1982-03-01

    Technical assistance in a preliminary design and economic evaluation of a geothermal heating system was provided. The use of a downhole heat exchanger was evaluated, with the objective of reducing costs in this first stage of the project, but was abandoned. The low resource temperature and lack of sufficient aquifer data were the reasons for abandonment of the downhole heat exchanger concept. The use of surface plate heat exchangers was selected as the preferred approach for utilizing the geothermal resource. Brine will be passed through three plate heat exchangers in the building basement. Separate loops of clean circulating fluid will be used to extract heat from the brine in three heat exchangers, with the loops providing heat to the building, a hot tub, and a deicing system. The cooled geothermal fluid from the heat exchangers will be injected to an isolated injection zone at the bottom of the production well. Aquifer tests are required to develop final pump sizes and process flows. The information developed from the work tasks of this project is presented.

  12. A novel system solution for cooling and ventilation in office buildings

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo;

    2015-01-01

    As a response to new energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need both in summer and in winter. In order to effectively save energy, new interests in cooling concepts using passive cooling technolo......As a response to new energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need both in summer and in winter. In order to effectively save energy, new interests in cooling concepts using passive cooling...... technologies and renewable energy sources have risen. Based on a literature review of natural ventilation, building thermal mass activation and diffuse ceiling ventilation, this paper proposes a new system solution combining these three technologies for cooling and ventilation in office buildings. This new...... solution has the special function of using natural ventilation all the year around without draught risk, even in very cold seasons. A case study of a typical office room using this solution and other traditional HVAC systems is carried out by energy simulation. The results show that there is a large energy...

  13. Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-06-01

    Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly large fraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

  14. Fuzzy-AHP-Based Comprehensive Evaluation on Facility Management System of High-Rise Office Buildings

    Institute of Scientific and Technical Information of China (English)

    ZHANG Peihong; WANG Kan; WAN Huanhuan; MA Zhongjiao

    2011-01-01

    The present building facility management status in China resulted in many problems such as highenergy consumption, failure of automation control, services failure and poor indoor air quality. Based onquestionnaires and interviews to professional engineers and building users, a comprehensive evaluation index system was established on facility management of high-rise office buildings. A Fuzzy AHP based upon hierarchy criteria system was established. A Fuzzy AHP Evaluation Model on Facility Management System was set up ;α-cut analysis was introduced and incorporated with expert knowledge together, which made up the optimism index λ. The fuzzy optimum crisp weight of each criterion was resulted from data-mining. Case investigations were processed in high-rise office buildings in Shenyang. The results illustrated that indoor air quality, thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings. Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection. By comparison with the analysis result of Export Choice, Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building.

  15. Grand Junction Projects Office Remedial Action Project Building 2 public dose evaluation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R.

    1996-05-01

    Building 2 on the U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) site, which is operated by Rust Geotech, is part of the GJPO Remedial Action Program. This report describes measurements and modeling efforts to evaluate the radiation dose to members of the public who might someday occupy or tear down Building 2. The assessment of future doses to those occupying or demolishing Building 2 is based on assumptions about future uses of the building, measured data when available, and predictive modeling when necessary. Future use of the building is likely to be as an office facility. The DOE sponsored program, RESRAD-BUILD, Version. 1.5 was chosen for the modeling tool. Releasing the building for unrestricted use instead of demolishing it now could save a substantial amount of money compared with the baseline cost estimate because the site telecommunications system, housed in Building 2, would not be disabled and replaced. The information developed in this analysis may be used as part of an as low as reasonably achievable (ALARA) cost/benefit determination regarding disposition of Building 2.

  16. A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Eliseeva, Ekaterina A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spears, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-10-07

    Background – This study investigated the associations of ventilation rates (VRs), estimated from indoor CO2 concentrations, in offices with the amount of respiratory infections, illness absences, and building-related health symptoms in occupants. Methods – Office buildings were recruited from three California climate zones. In one or more study spaces within each building, real-time logging sensors measured carbon dioxide, temperature, and relative humidity for one year. Ventilation rates were estimated using daily peak CO2 levels, and also using an alternative metric. Data on occupants and health outcomes were collected through web-based surveys every three months. Multivariate models were used to assess relationships between metrics of ventilation rate or CO2 and occupant outcomes. For all outcomes, negative associations were hypothesized with VR metrics, and positive associations with CO2 metrics. Results – Difficulty recruiting buildings and low survey response limited sample size and study power. In 16 studied spaces within 9 office buildings, VRs were uniformly high over the year, from twice to over nine times the California office VR standard (7 L/s or 15 cfm per person). VR and CO2 metrics had no statistically significant relationships with occupant outcomes, except for a small significantly positive association of the alternative VR metric with respiratory illness-related absence, contrary to hypotheses. Conclusions– The very high time-averaged VRs in the California office buildings studied presumably resulted from “economizer cycles” bringing in large volumes of outdoor air; however, in almost all buildings even the estimated minimum VRs supplied (without the economizer) substantially exceeded the minimum required VR. These high VRs may explain the absence of hypothesized relationships with occupant outcomes. Among uniformly high VRs, little variation in contaminant concentration and occupant effects would be expected. These findings may

  17. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou

    2014-01-01

    ventilation compared to those for displacement ventilation. Due to the heat emission from equipments and occupants, heating system was not needed in the low energy office building in a mild winter. In such a situation, indoor thermal environment was still acceptable in terms of the general thermal comfort......The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied...

  18. Analysing Legibility of Space in Office Buildings: Case Studies in Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Sahar Soltani

    2016-07-01

    Full Text Available Most people spend a substantial amount of time at work. Despite this significant role, office buildings incur some functional and environmental problems for users, one of the most critical of which is to access and move easily through them regarding their mostly complicated spatial configuration. The aim of this study is to understand the relationship between legibility and different building typology in addition to achieving some design patterns by comparing them. In this connection, the role of physical context and different design typology of some office buildings in Kerman have been investigated with the aim of analyzing interior legibility and way finding. Accordingly, observation and interviews were conducted to complete the evidences found from VGA results of the space syntax software along with self - administered questionnaires of employees and clients. The results based on the analysis of the strengths and weaknesses of these office buildings in terms of legibility and way finding suggest some recommendations and guidelines so that they can contribute to promoting the future of office buildings design

  19. Analysis and design of a multi - storey office building in Celje

    OpenAIRE

    Kržan, Rok

    2013-01-01

    The thesis analyses the load bearing structure of an existing multi storey office building in Celje. The load bearing structure is made of reinforced concrete, based on strip and isolated foundation footings, slabs, columns and walls. It is analysed with the programme Tower7, which utilises the final elements method. Two computational models of the load bearing structure are built. The first one is used to analyse the typical ceiling construction in the building. Besides the slab,...

  20. Issues to Be Solved for Energy Simulation of An Existing Office Building

    Directory of Open Access Journals (Sweden)

    Ki Uhn Ahn

    2016-04-01

    Full Text Available With the increasing focus on low energy buildings and the need to develop sustainable built environments, Building Energy Performance Simulation (BEPS tools have been widely used. However, many issues remain when applying BEPS tools to existing buildings. This paper presents the issues that need to be solved for the application of BEPS tools to an existing office building. The selected building is an office building with 33 stories above ground, six underground levels, and a total floor area of 91,898 m2. The issues to be discussed in this paper are as follows: (1 grey data not ready for simulation; (2 subjective assumptions and judgments on energy modeling; (3 stochastic characteristics of building performance and occupants behavior; (4 verification of model fidelity-comparison of aggregated energy; (5 verification of model fidelity-calibration by trial and error; and (6 use of simulation model for real-time energy management. This study investigates the aforementioned issues and explains the factors that should be considered to address these issues when developing a dynamic simulation model for existing buildings.

  1. Solar Shading in Low Energy Office Buildings - Design Strategy and User Perception

    Directory of Open Access Journals (Sweden)

    Steinar Grynning

    2017-06-01

    Full Text Available The objective of this paper is to investigate the visual comfort and quality of daylight in modern office buildings in the Nordic climate. A study of various daylight-related aspects and qualities was carried out for three different office buildings, using a combination of quantitative and qualitative methods. The focus was on a combination of user perception of daylight quality and assessment of the daylight amount and quality, by using the daylight factor (DF and useful daylight illuminance parameters. Previous studies and experiences from construction examples indicate that users, in general, complain about lack of manual control of systems and too low daylight levels, even if the requirements in the building codes are satisfied. Furthermore, they complain about control algorithms of the shading devices, which cause undesired automatic opening and closure of such devices. Thus, causing disturbances and irritation amongst the users. Hence, interviews with key personnel in a modern and architecturally acclaimed office building were carried out in addition to an in-depth analysis of previous surveys of a zero-energy office building. It was found that automatic moveable shading can be regarded as a source of discomfort. This is due to the lack of manual-control override possibilities, which causes disturbances due to the system moving up and down. In one of the offices, the users disabled the exterior shading system. However, the external fixed shading and the internal manually operated roller blinds were found to be satisfactory. The results from a previous study showed that the users in the Marche building are in general satisfied with the daylight. One of the main reasons for this, according to the users, is that they have manual control of the shading system. Manual control of the shading systems is preferred by users in the office buildings studied. Daylight simulations showed that the external fixed shading system combined with internal

  2. Characterizing Indoor Airflow and Pollutant Transport using Simulation Modeling for Prototypical Buildings. I. Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, M.D.; Daisey, J.M.; Feustel, H.E.

    1999-06-01

    This paper describes the first efforts at developing a set of prototypical buildings defined to capture the key features affecting airflow and pollutant transport in buildings. These buildings will be used to model airflow and pollutant transport for emergency response scenarios when limited site-specific information is available and immediate decisions must be made, and to better understand key features of buildings controlling occupant exposures to indoor pollutant sources. This paper presents an example of this approach for a prototypical intermediate-sized, open style, commercial building. Interzonal transport due to a short-term source release, e.g., accidental chemical spill, in the bottom and the upper floors is predicted and corresponding HVAC system operation effects and potential responses are considered. Three-hour average exposure estimates are used to compare effects of source location and HVAC operation.

  3. Façade system for existing office buildings in Copenhagen

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Michael

    2015-01-01

    This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements....... The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re...

  4. Energy edge post-occupancy evaluation project: The Landmark Office Building, Yalima, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    The Landmark Office Building Survey for the Energy Edge Post- Occupancy Project was administered to thirty of the building occupants. Eighteen respondents answered the questions which rated building features in the areas of (1) thermal factors; (2) air quality; (3) lighting; (4) acoustics; and, (5) overall workspace satisfaction. In addition to rating these ambient environmental features, these respondents also rated their satisfaction of various functional and aesthetic features and specific kinds of workplaces. Data was also collected on health characteristics and occupational demographics of the respondents. No analysis is made of the survey findings which are reported in graphic and tabular format. 20 figs., 8 tabs.

  5. Energy edge post-occupancy evaluation project: the Hollywood Office Building, Portland, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    The Hollywood Office Park Building Survey for the Energy Post- Occupancy Project was administered to nine building occupants. The nine respondents answered the questions which rated building features in the areas of (1) thermal factors; (2) air quality; (3) lighting; (4) acoustics; and, (5) overall workspace satisfaction. In addition to rating these ambient environmental features, these respondents also rated their satisfaction of various functional and aesthetic features and specific kinds of workspaces. Data was also collected on heath characteristics and occupational demographics of the respondents. No analysis is made of the survey findings which are reported in graphic format. 15 figs. (BN)

  6. Multi-angled Façade System for Office Building Renovation

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Michael

    renovating office buildings. The architectural potential is presented with the help of AutoCAD software. The energy efficiency and indoor climate are investigated and evaluated by using correlational research and simulation research methods with the software IDA ICE. From a functional perspective, the multi...

  7. Multi-angled façade system for office building renovation

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Lauring, Michael; Christensen, Jørgen Erik

    2016-01-01

    renovating office buildings. The architectural potential is presented with the help of AutoCAD software. The energy efficiency and indoor climate are investigated and evaluated by using correlational research and simulation research methods with the software IDA ICE. From a functional perspective, the multi...

  8. Modeling of a Novel Low-Exergy System for Office Buildings with Modelica

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Afshari, Alireza; Hultmark, Göran

    2016-01-01

    This paper aims to investigate the thermal behavior of a novel low-exergy system for office buildings. The main characteristic of the system is its ability to provide simultaneous heating and cooling by operating one water circuit. Inlet water temperature of about 22 °C is delivered to all...

  9. Sick building syndrome: Acute illness among office workers--the role of building ventilation, airborne contaminants and work stress

    Energy Technology Data Exchange (ETDEWEB)

    Letz, G.A. (Univ. of California, San Francisco (USA))

    1990-05-01

    Outbreaks of acute illness among office workers have been reported with increasing frequency during the past 10-15 years. In the majority of cases, hazardous levels of airborne contaminants have not been found. Generally, health complaints have involved mucous membrane and respiratory tract irritation and nonspecific symptoms such as headache and fatigue. Except for rare examples of hypersensitivity pneumonitis related to microbiologic antigens, there have been no reports of serious morbidity or permanent sequelae. However, the anxiety, lost work time, decreased productivity and resources spent in investigating complaints has been substantial. NIOSH has reported on 446 Health Hazards Evaluations that were done in response to indoor air complaints. This data base is the source of most of the published accounts of building-related illness. Their results are summarized here with a discussion of common pollutants (tobacco smoke, formaldehyde, other organic volatiles), and the limitations of the available industrial hygiene and epidemiologic data. There has been one large scale epidemiologic survey of symptoms among office workers. The results associate risk of symptoms to building design and characteristics of the heating/air-conditioning systems, consistent with the NIOSH experience. Building construction since the 1970s has utilized energy conservation measures such as improved insulation, reduced air exchange, and construction without opening windows. These buildings are considered airtight and are commonly involved in episodes of building-associated illness in which no specific etiologic agent can be identified. After increasing the percentage of air exchange or correcting specific deficiencies found in the heating/air-conditioning systems, the health complaints often resolve, hence, the term tight building syndrome or sick building syndrome.

  10. Regional Energy Study Zahorie, Slovakia. Building energy audits. Part 4. Nafta Gbely office building, Malacky

    Energy Technology Data Exchange (ETDEWEB)

    Kaan, H.F.

    1995-10-01

    The building was audited by means of a visual inspection of building quality, energy aspects and quality and performance of appliances. Additional information came from drawings, energy bills and design documents. Information about management aspects was obtained by interviews with the management of the building. In general it may be concluded, that energy saving potential is rather high. Energy savings can be obtained in the first place by improving the energy management. However, technical measures are required as well. Some of these do not ask for high investments and should directly be implemented. But high cost measures are required as well. 5 tabs., 1 refs., 1 appendix

  11. Impacts of orientation on daylighting in high-rise office buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    AbdolHamid Mahdavi

    2015-12-01

    Full Text Available Orientation is one of the important factors in building design to use daylight and ‎conserve energy. Well-orientated buildings maximise daylight reception through ‎building facades and reduce the need for artificial lighting. Reasonable daylighting usage in office buildings is an important part of an architect’s designing process, which leads to lesser electricity consumption as well as providing a visual and thermal comfort for the occupants. Orientation is an important factor in passive design strategies. This paper focuses on the orientation effect on daylighting into office rooms. The research method of this study was simulation which is performed on a hypothetical model on a 25 storey high-rise office building in Malaysia. All simulations were carried out in the IES-VE software that uses RADIANCE program for illuminance calculations. To evaluate the daylight in various conditions, a new index SAZ was introduced which assesses daylight factor (DF and absolute Lux. Results showed similar SAZ in CIE overcast sky in various orientations; whereas, in sunny sky due to sun path in Malaysia, different results showed northern and southern rooms have the best illuminance distribution. However, the similar window form and size in four orientations lead to more energy consumption for artificial lighting and cooling loads.

  12. An Adaptive Intelligent Integrated Lighting Control Approach for High-Performance Office Buildings

    Science.gov (United States)

    Karizi, Nasim

    An acute and crucial societal problem is the energy consumed in existing commercial buildings. There are 1.5 million commercial buildings in the U.S. with only about 3% being built each year. Hence, existing buildings need to be properly operated and maintained for several decades. Application of integrated centralized control systems in buildings could lead to more than 50% energy savings. This research work demonstrates an innovative adaptive integrated lighting control approach which could achieve significant energy savings and increase indoor comfort in high performance office buildings. In the first phase of the study, a predictive algorithm was developed and validated through experiments in an actual test room. The objective was to regulate daylight on a specified work plane by controlling the blind slat angles. Furthermore, a sensor-based integrated adaptive lighting controller was designed in Simulink which included an innovative sensor optimization approach based on genetic algorithm to minimize the number of sensors and efficiently place them in the office. The controller was designed based on simple integral controllers. The objective of developed control algorithm was to improve the illuminance situation in the office through controlling the daylight and electrical lighting. To evaluate the performance of the system, the controller was applied on experimental office model in Lee et al.'s research study in 1998. The result of the developed control approach indicate a significantly improvement in lighting situation and 1-23% and 50-78% monthly electrical energy savings in the office model, compared to two static strategies when the blinds were left open and closed during the whole year respectively.

  13. The effect of renovating an office building on occupants' comfort and health

    DEFF Research Database (Denmark)

    Pejtersen, Jan; Brohus, H.; Hyldgaard, C.E.

    1999-01-01

    An intervention study was performed in an office building in which there were severe indoor climate complaints among the occupants. In one part of the building a new heating and ventilation strategy was implemented by renovating the HVAC system, and a carpet floor material was replaced with a low......-emitting vinyl floor; the other part of the building was kept unchanged, serving as a control. A comprehensive indoor climate investigation, including a questionnaire study of the occupants' comfort and health, was performed before and after the intervention. The intervention was performed after detailed...... laboratory studies on alternative flooring materials and alternative ventilation strategies. The occupants' adverse perceptions and symptoms were significantly reduced by the intervention. The improvement of the indoor climate was most pronounced in the cellular offices, where both the floor material...

  14. The Green Electricity: The Potential of Using Solar Pv Panel for The Royal Malaysian Police (RMP Building

    Directory of Open Access Journals (Sweden)

    Md Yasin Md Hafiz

    2016-01-01

    Full Text Available As the year 2020 approaches, Malaysia aims to be self-sufficient and independence in finding resources to fuel its development, especially in energy sector. To achieve this aims, Malaysia need to strengthen its energy sustainability aspect and have a clear foresight in handling energy security issue. In coming decades, energy crisis due the existence of the significant energy threat may cause power interruptions and lead to many interrelated problems, especially safety and security issues. Issues such as unstable political and economic situation in Middle East country, Spratly issue, South China Sea territorial issue, war and terrorist may lead to unstable safety and security environment for Malaysia. The most significant organization to keep the safety and security of Malaysia is The Royal Malaysian Police (RMP. However, at the moment, this organization is fully-reliant on centralized electricity supply that may interrupt due to the future energy threat. Therefore, it is important for this organization to have an independence and self-sufficient electricity supply in order to remain their operation in any circumstances .The solar energy, through Photovoltaic (PV panel, has been identified as the significant resources to achieve this purposes. With constant solar irradiance, Malaysia has great potential in solar energy harvesting. The energy is clean, environmental-friendly, reliable and readily-accessible throughout the year. This paper will review the potential of green electricity through solar PV in being the power supply for RMP in order to maintain the security and safety of Malaysia

  15. Assessment Framework of Building Facade in Optimizing Indoor Thermal Comfort of Green Building Index (GBI) Certified Office Building

    OpenAIRE

    Abdul Tharim Asniza Hamimi; Abdul Samad Muna Hanim

    2016-01-01

    During the past decade, the construction industry has seen a new trend in the development of “green” or “sustainable” construction concept around the world with vast support from prominent organization, together with the introduction of sustainable building codes. The establishment of green building certification systems worldwide is seen as one of the most efforts in the emerging green building movement. In order to support the development of the “green” and “sustainable” concept in Malaysia...

  16. Operative temperature drifts and occupant satisfaction with thermal environment in three office buildings using radiant heating/ cooling system

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Olesen, Bjarne W.

    2015-01-01

    The objective of this study was to analyse operative temperature drifts and occupant satisfaction with thermal environment in office buildings utilizing embedded radiant heating/cooling systems. Three office buildings were investigated: Town Hall in Viborg, Denmark (floor area 19400 m2), IDOM...

  17. Revealing Occupancy Patterns in Office Buildings Through the use of Annual Occupancy Sensor Data

    Energy Technology Data Exchange (ETDEWEB)

    Carlos Duarte; Kevin Van Den Wymelenberg; Craig Rieger

    2013-06-01

    Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

  18. Field test of a thermal active building system (tabs) in an office building in Denmark

    DEFF Research Database (Denmark)

    Raimondo, Daniela; Olesen, Bjarne W.; Corgnati, Stefano P.

    2013-01-01

    in the indoor environmental assessment of a building. At the same time, also use of low temperature heating and high temperature cooling systems in non-residential buildings has increased, due to the energy efficiency and the economical cooling and heating performance of tins kind of plants. This paper presents...... were carried out monitoring air and operative temperature, relative humidity and CO2 levels in the room where internal heat gains from people where controlled and simulated by heated dummies positioned at the same workstations used by employees during the workdays. Supply and return water temperature...

  19. Energy and thermal analysis of glazed office buildings using a dynamic energy simulation tool

    Energy Technology Data Exchange (ETDEWEB)

    Poirazis, H.; Blomsterberg, A. [Lund Inst. of Technology, Lund (Sweden). Div. of Energy and Building Design

    2005-07-01

    Although highly glazed buildings have more access to daylight than traditional buildings their energy efficiency is sometimes questionable. This paper presented energy and indoor climate simulations of single skin office buildings in Sweden with the use of a dynamic energy simulation tool. An analysis of building alternatives with 30, 60 and 100 per cent window areas were investigated. Parameters concerning the buildings' orientation, plan type, control set points and facade type were varied in the simulations. A virtual reference building was created as representative of Swedish office buildings constructed in the late 1990s. The design was determined by various Swedish agencies. Detailed performance specifications for energy and indoor climate were established and typical construction methods were determined. System descriptions and drawings were prepared. A validation of the simulated performance of the building showed that the performance specifications were accurate. A parametric study of energy use and indoor climate was conducted. Heating, ventilation and air conditioning (HVAC) systems and control systems were described in detail. Orientation, plan type, control set points, and facade elements were changed while other parameters such as the shape of the building and occupant activity levels remained the same. A sensitivity analysis was conducted regarding occupant comfort levels and the energy used for operating the building. It was concluded that the energy efficiency of a building depends on facade construction. It was suggested that highly glazed buildings will benefit through the use of advanced simulation tools during the design stage. It was also noted that the main aim when designing glazed buildings should be to avoid a high cooling demand. The impact of control set points on heating and cooling is also crucial for energy use, as well as the orientation of rooms. It was suggested that an increase in glazing area does not necessarily mean higher

  20. Review of the potential of passive solar strategies for office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L.

    1983-08-01

    The objectives of this study were to determine the potential for reducing energy use in office buildings by the adoptation of passive solar strategies and to identify and evaluate the potential of new technologies that could be developed. The study involved modelling various building configurations and passive strategies for an office building located in Ottawa using the DOE-2 energy analysis program. The intent of the study has been to evaluate the theoretical potential of the various passive options (such as daylighting, increasing south glazing, solar shading, and insulated shutter) to determine whether a particular option has a potentially worthwhile benefit before trying to solve any associated problems. The main conclusions reached during this study were that south facing glass has the potential for reducing energy consumption if there is complete thermal mixing and shading is used to minimize unwanted solar gains; ''switchable'' glazings are a particularly attractive technology to pursue; minimum envelope, deep-plan office buildings are not the most energy efficient solution; and the addition of an atrium increases energy consumption although an additonal semi-heated amenity area is provided. 24 refs., 47 figs., 18 tabs.

  1. Building construction materials effect in tropical wet and cold climates: A case study of office buildings in Cameroon

    Directory of Open Access Journals (Sweden)

    Modeste Kameni Nematchoua

    2016-03-01

    Full Text Available This paper presents the results of an experimental study that was conducted in 15 office buildings in the humid and cold tropics during the working hours of the dry and rainy seasons in Cameroon. This was with the aim to study the effects that local and imported materials had on indoor air quality. To achieve this objective, the adaptive model approach has been selected. In accordance with the conditions of this model, all workers were kept in natural ventilation and, in accordance with the general procedure, a questionnaire was distributed to them, while variables, like air temperature, wind speed, and relative humidity were sampled. The results showed a clear agreement between expected behaviour, in accordance with the characteristics of building construction, and its real indoor ambience once they were statistically analysed. On the other hand, old buildings showed a higher percentage of relative humidity and a lower degree of indoor air temperature. Despite this, local thermal comfort indices and questionnaires showed adequate indoor ambience in each group of buildings, except when marble was used for external tiling. The effect of marble as an external coating helps to improve indoor ambience during the dry season. This is due to more indoor air and relative humidity being accumulated. At the same time, these ambiences are degraded when relative humidity is higher. Finally, these results should be taken cognisance of by architects and building designers in order to improve indoor environment, and overcome thermal discomfort in the Saharan area.

  2. Office of Codes and Standards resource book. Section 1, Building energy codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1995-01-01

    The US Department of Energy`s (DOE`s) Office of Codes and Standards has developed this Resource Book to provide: A discussion of DOE involvement in building codes and standards; a current and accurate set of descriptions of residential, commercial, and Federal building codes and standards; information on State contacts, State code status, State building construction unit volume, and State needs; and a list of stakeholders in the building energy codes and standards arena. The Resource Book is considered an evolving document and will be updated occasionally. Users are requested to submit additional data (e.g., more current, widely accepted, and/or documented data) and suggested changes to the address listed below. Please provide sources for all data provided.

  3. Plug-Load Control and Behavioral Change Research in GSA Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, I.; Cutler, D.; Sheppy, M.

    2012-10-01

    The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

  4. Passive-solar-cooling system concepts for small office buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Whiddon, W.I.; Hart, G.K.

    1983-02-01

    This report summarizes the efforts of a small group of building design professionals and energy analysis experts to develop passive solar cooling concepts including first cost estimates for small office buildings. Two design teams were brought together at each of two workshops held in the fall of 1982. Each team included an architect, mechanical engineer, structural engineer, and energy analysis expert. This report presents the passive cooling system concepts resulting from the workshops. It summarizes the design problems, solutions and first-cost estimates relating to each technology considered, and documents the research needs identified by the participants in attempting to implement the various technologies in an actual building design. Each design problem presented at the workshops was based on the reference (base case) small office building analyzed as part of LBL's Cooling Assessment. Chapter II summarizes the thermal performance, physical specifications and estimated first-costs of the base case design developed for this work. Chapters III - VI describe the passive cooling system concepts developed for each technology: beam daylighting; mass with night ventilation; evaporative cooling; and integrated passive cooling systems. The final Chapters, VII and VIII present the preliminary implications for economics of passive cooling technologies (based on review of the design concepts) and recommendations of workshop participants for future research in passive cooling for commercial buildings. Appendices provide backup information on each chapter as indicated.

  5. A study on the usage and perceptions of office building occupants to green roofs in Hong Kong

    OpenAIRE

    2014-01-01

    As Hong Kong is famous for its image of leading international financial metropolis, many high-rise office buildings are confined inside some developed commercial districts of Hong Kong. A place for provision of greenery in such districts seems impracticable. However, greenery can exist in forms of green roof onto office buildings, it seems a practical way to embellish this concrete city. Academic studies from other countries have proven that having green roof onto buildings is able to bri...

  6. Structural design of a two storey office building and production facility

    OpenAIRE

    Nučič, Gregor

    2016-01-01

    The Graduation Thesis shows the process of structural analysis and design of key elements of the steel structure. The building has a rectangular floor shape, dimensions of 12.10 m and 32.20 m. Building height is 9.50 m. Construction is a two storey facility. On the ground floor is planed production and storage unit, on the first floor there would be offices. The project is designed in accordance with the valid European standards Eurocodes and related Slovenian national annex. Design of struct...

  7. Energy savings modelling of re-tuning energy conservation measures in large office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin; Huang, Yunzhi; Liu, Guopeng

    2014-10-20

    Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy

  8. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou;

    2014-01-01

    The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied....../s for both ventilation systems. In addition, local ventilation effectiveness ranged from 0.91 to 0.94 for mixing ventilation and from 1.03 to 1.17 for displacement ventilation. Distributions of vertical air temperature and velocity and horizontal contaminant concentration were more uniform for mixing...... ventilation compared to those for displacement ventilation. Due to the heat emission from equipments and occupants, heating system was not needed in the low energy office building in a mild winter. In such a situation, indoor thermal environment was still acceptable in terms of the general thermal comfort...

  9. Measuring Instrument Constructs of Return Factors for Green Office Building Investments Variables Using Rasch Measurement Model

    Directory of Open Access Journals (Sweden)

    Isa Mona

    2016-01-01

    Full Text Available This paper is a preliminary study on rationalising green office building investments in Malaysia. The aim of this paper is attempt to introduce the application of Rasch measurement model analysis to determine the validity and reliability of each construct in the questionnaire. In achieving this objective, a questionnaire survey was developed consists of 6 sections and a total of 106 responses were received from various investors who own and lease office buildings in Kuala Lumpur. The Rasch Measurement analysis is used to measure the quality control of item constructs in the instrument by measuring the specific objectivity within the same dimension, to reduce ambiguous measures, and a realistic estimation of precision and implicit quality. The Rasch analysis consists of the summary statistics, item unidimensionality and item measures. A result shows the items and respondent (person reliability is at 0.91 and 0.95 respectively.

  10. Use of infrared thermography in detection, remediation, and commissioning of thermal comfort problems in office buildings

    Science.gov (United States)

    Colantonio, Antonio

    2001-03-01

    Thermal comfort complaints within work places are one of the leading causes of workforce productivity loss within office environments. Generally, mechanical systems are relied on to provide adequate indoor environments. In many situations, these systems cannot provide suitable work environments due to unacceptable asymmetrical radiant temperature conditions found in exterior zones of building interiors. Public Works and Government Services Canada (PWGSC) has developed methodologies using infrared technology to assist building and office managers in reducing thermal comfort complaints and improve workforce productivity. Detection, verification, remediation and commissioning of solutions are easily and effectively carried out with the assistance of infrared radiometers and proper inspection and analysis procedures. This paper will outline two case studies and detail methodologies used in each case.

  11. A Non-linear Stochastic Model for an Office Building with Air Infiltration

    DEFF Research Database (Denmark)

    Thavlov, Anders; Madsen, Henrik

    2015-01-01

    This paper presents a non-linear heat dynamic model for a multi-room office building with air infiltration. Several linear and non-linear models, with and without air infiltration, are investigated and compared. The models are formulated using stochastic differential equations and the model param...... heat load reduction during peak load hours, control of indoor air temperature and for generating forecasts of power consumption from space heating....

  12. [Biological contamination in office buildings related to ventilation/air conditioning system].

    Science.gov (United States)

    Bródka, Karolina; Sowiak, Małgorzata; Kozajda, Anna; Cyprowski, Marcin; Irena, Szadkowska-Stańczyk

    2012-01-01

    Indoor air is contaminated with microorganisms coming from both the atmospheric air and sources present in premises. The aim of this study was to analyze the concentrations of biological agents in office buildings, dependending on ventilation/air conditioning system and season. The study covered office buildings (different in the system of ventila-tion/air conditioning). Air samples for assessing the levels of inhalable dust, endotoxins and (1-->3)-beta-D-glucans, were taken at the selected stationary points of each building during summer and winter. The air was sampled for 6 h, using portable sets consisting of the GilAir 5 pump and the head filled with a filter of fiber glass. The samples for the presence of airborne bacteria and fungi were collected twice during the day using the impaction method. Average concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans in office premises were 0.09 mg/m3, 6.00 x 10(2) cfu/m3, 4.59 x 10(1) cfu/m3, 0.42 ng/m3 and 3.91 ng/m3, respectively. Higher concentrations of the investigated agents were found in summer. In premises with air conditioning concentrations of airborne fungi, (1-->3)-beta-D-glucans and inhalable dust were significantly lower in winter. In summer the trend was reverse except for (1-->3)-beta-D-glucans. Concentrations of biological agents were affected by the season and the presence of air conditioning. Concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans, observed inside the office buildings, were significantly higher in summer than in winter. The presence of the air conditioning system modified in various ways the levels of biological agents. Its influence was greater on the concentration of fungi and (1-->3)-beta-D-glucans than on that of bacteria and endotoxins.

  13. Solar energy system installed at the North Georgia APDC office building

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    Information is provided on the solar energy system installed in the newly constructed office building of the North Georgia Area Planning and Development Commission near downtown Dalton, Georgia. This solar heating, cooling and hot water system supplies 65 to 70% of the cooling demand and 90 to 95% of the heating demand. There are 2,001 square feet of effective Revere collector area, and the absorption chiller is in Arkla model 300 and provides 16 tons of cooling.

  14. Occupant comfort, control, and satisfaction in three California mixed-mode office buildings

    OpenAIRE

    Ring, Erik W; Brager, Gail S.

    2000-01-01

    This report outlines the results from an occupant survey of satisfaction with thermal comfort and air quality in three California mixed-mode office buildings. Mixed-mode refers to the relatively new design strategy of explicitly integrating natural ventilation with mechanical cooling and ventilation services. Each of the research sites includes operable windows along with a complete HVAC system. Survey results indicate that access to operable windows has a significant positive impact on repor...

  15. Sustainable energy planning with efficient office buildings and cogeneration plants in Frankfurt am Main.

    Science.gov (United States)

    Friedel, Wendelin; Neumann, Werner

    2004-06-01

    Sustainable development of a city not only is determined through the amount of protected areas, but it is also an important task to integrate sustainable development in urban energy planning. In the last 10 years, many new areas for offices and residential buildings have been developed in Frankfurt am Main. In this context, the municipality has taken over a new role as organizer for the integrated energy planning. This article gives an overview of the achievements.

  16. Solar heating and cooling system for an office building at Reedy Creek Utilities

    Science.gov (United States)

    1978-01-01

    The solar energy system installed in a two story office building at a utilities company, which provides utility service to Walt Disney World, is described. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled water. Performance to date has equaled or exceeded design criteria.

  17. Experimental verification of an energy consumption signal tool for operational decision support in an office building

    Energy Technology Data Exchange (ETDEWEB)

    Pavlak, Gregory S.; Henze, Gregor P.; Hirsch, Adam I.; Florita, Anthony R.; Dodier, Robert H.

    2016-12-01

    This paper demonstrates an energy signal tool to assess the system-level and whole-building energy use of an office building in downtown Denver, Colorado. The energy signal tool uses a traffic light visualization to alert a building operator to energy use which is substantially different from expected. The tool selects which light to display for a given energy end-use by comparing measured energy use to expected energy use, accounting for uncertainty. A red light is only displayed when a fault is likely enough, and abnormal operation costly enough, that taking action will yield the lowest cost result. While the theoretical advances and tool development were reported previously, it has only been tested using a basic building model and has not, until now, been experimentally verified. Expected energy use for the field demonstration is provided by a compact reduced-order representation of the Alliance Center, generated from a detailed DOE-2.2 energy model. Actual building energy consumption data is taken from the summer of 2014 for the office building immediately after a significant renovation project. The purpose of this paper is to demonstrate a first look at the building following its major renovation compared to the design intent. The tool indicated strong under-consumption in lighting and plug loads and strong over-consumption in HVAC energy consumption, which prompted several focused actions for follow-up investigation. In addition, this paper illustrates the application of Bayesian inference to the estimation of posterior parameter probability distributions to measured data. Practical discussion of the application is provided, along with additional findings from further investigating the significant difference between expected and actual energy consumption.

  18. Thermal and lighting perception in four fully glazed office buildings in Santiago, Chile

    Directory of Open Access Journals (Sweden)

    Claudio Vásquez

    2013-12-01

    Full Text Available Corresponding author: Claudio Vásquez, School of Architecture, Catholic University of Chile. 1916 El Comendador str. Providencia, Santiago, ZIP: 7530091, Chile. Tel.: +56 9 92826305; E-mail: clvasque@uc.cl This paper is part of a general research project whose main objective is to establish a baseline for post-occupancy energy consumption and indoor environmental quality for office buildings in Santiago, Chile. This study aims at understanding how architectonical variables relate to, and can even determine, user comfort perception. Thus, one-year continuous monitoring in several floors at four office buildings was performed and seasonal surveys were completed. Survey participants were asked a series of questions regarding spatial orientation and comfort perception in their workspace. The data from the comfort survey and onsite measurements such as season of the year, case study, type of workspace and possibility of an outdoor view from the workstation were contrasted with the components obtained by a Principal Component Analysis (PCA. Three components were selected from the PCA, and three Maps of Perception (MP were produced. These maps were then analyzed and interpreted so as to obtain information on the general perception of thermal and lighting comfort at workspaces within several office buildings in Santiago.

  19. Thermal and lighting perception in four fully glazed office buildings in Santiago, Chile

    Directory of Open Access Journals (Sweden)

    Claudio Vásquez Záldivar

    2013-12-01

    Full Text Available This paper is part of a general research project whose main objective is to establish a baseline for post-occupancy energy consumption and indoor environmental quality for office buildings in Santiago, Chile. This study aims at understanding how architectonical variables relate to, and can even determine, user comfort perception.  Thus, one-year continuous monitoring in several floors at four office buildings was performed and seasonal surveys were completed.  Survey participants were asked a series of questions regarding spatial orientation and comfort perception in their workspace.The data from the comfort survey and onsite measurements such as season of the year, case study, type of workspace and possibility of an outdoor view from the workstation were contrasted with the components obtained by a Principal Component Analysis (PCA. Three components were selected from the PCA, and three Maps of Perception (MP were produced. These maps were then analyzed and interpreted so as to obtain information on the general perception of thermal and lighting comfort at workspaces within several office buildings in Santiago.

  20. A study of the impact of environmental loads that penetrate a passive skylight roofing system in Malaysian buildings

    Directory of Open Access Journals (Sweden)

    Karam M. Al-Obaidi

    2014-06-01

    Full Text Available A passive skylight system is a significant building design element that provides an ideal condition for interior spaces. However, the use of this system is limited to specific climatic regions because of its considerable effect on the indoor environment. Malaysia is a tropical country that has favorable natural benefits, such as solar geometry and natural light, which can brighten building interiors throughout the year. However, harnessing this benefit affects spaces, especially those in single-story buildings, because of excessive natural loads. This study reviews a concept to understand the passive behavior of solar radiation in the form of light and heat that falls on, interacts with, and is emitted from a skylight system in a single-story building. The study method is theoretically based on descriptive analysis to assess design requirements. The review shows that designs grounded on the physical aspects of climate (influenced variables, materials (design variables, and human comfort (affected variables in one process (ESI can develop the architectural way of thinking rather than estimate the condition based on a limited perspective. This assumption indicates that the adoption of this concept in the preliminary design stage will enable designers to balance the building environment effectively.

  1. Assessment of energy and economic performance of office building models: a case study

    Science.gov (United States)

    Song, X. Y.; Ye, C. T.; Li, H. S.; Wang, X. L.; Ma, W. B.

    2016-08-01

    Energy consumption of building accounts for more than 37.3% of total energy consumption while the proportion of energy-saving buildings is just 5% in China. In this paper, in order to save potential energy, an office building in Southern China was selected as a test example for energy consumption characteristics. The base building model was developed by TRNSYS software and validated against the recorded data from the field work in six days out of August-September in 2013. Sensitivity analysis was conducted for energy performance of building envelope retrofitting; five envelope parameters were analyzed for assessing the thermal responses. Results indicated that the key sensitivity factors were obtained for the heat-transfer coefficient of exterior walls (U-wall), infiltration rate and shading coefficient (SC), of which the sum sensitivity factor was about 89.32%. In addition, the results were evaluated in terms of energy and economic analysis. The analysis of sensitivity validated against some important results of previous studies. On the other hand, the cost-effective method improved the efficiency of investment management in building energy.

  2. Artificial neural networks for energy analysis of office buildings with daylighting

    Energy Technology Data Exchange (ETDEWEB)

    Wong, S.L.; Wan, Kevin K.W.; Lam, Tony N.T. [Building Energy Research Group, Department of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR (China)

    2010-02-15

    An artificial neural network (ANN) model was developed for office buildings with daylighting for subtropical climates. A total of nine variables were used as the input parameters - four variables were related to the external weather conditions (daily average dry-bulb temperature, daily average wet-bulb temperature, daily global solar radiation and daily average clearness index), four for the building envelope designs (solar aperture, daylight aperture, overhang and side-fins projections), and the last variable was day type (i.e. weekdays, Saturdays and Sundays). There were four nodes at the output layer with the estimated daily electricity use for cooling, heating, electric lighting and total building as the output. Building energy simulation using EnergyPlus was conducted to generate daily building energy use database for the training and testing of ANNs. The Nash-Sutcliffe efficiency coefficient for the ANN modelled cooling, heating, electric lighting and total building electricity use was 0.994, 0.940, 0.993, and 0.996, respectively, indicating excellent predictive power. Error analysis showed that lighting electricity use had the smallest errors, from 0.2% under-estimation to 3.6% over-estimation, with the coefficient of variation of the root mean square error ranging from 3% to 5.6%. (author)

  3. Statistical simulation of user behaviour in low-energy office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Pfafferott, J.; Herkel, S. [Fraunhofer Institute for Solar Energy Systems, Heidenhofstr. 2, D-79110 Freiburg (Germany)

    2007-05-15

    A large number of design guidelines and tools are available for the design of passive cooling systems. Using the underlying thermodynamic models, a certain input (e.g. air change rate, internal heat gains or sun control) results in a certain output (i.e. room temperature). However, in real buildings the room temperature at a given outdoor temperature is a distribution rather than a single value. Therefore, the building engineer should take uncertainties into account, since the actual use of the building, the building physical properties or the user behaviour are statistically distributed. One promising approach to include these uncertainties in the design procedure is the use of statistical models: the design parameter is defined by a mean value and its deviation. From a control theoretical point of view, the deterministic controlled system responds to random disturbance variables by a statistically distributed response function. Considering the institute building of Fraunhofer ISE as example, this study shows how statistical simulations can be applied to the design process of passive cooling in low-energy office buildings. (author)

  4. Realization of a demand response in office-buildings; Umsetzung eines Lastmangements in Buerogebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Jungwirth, Johannes; Berger, Christian [TU Muenchen (Germany). Lehrstuhl fuer Energiewirtschaft und Anwendungstechnik; Roessel, Timm [TU Muenchen (Germany). Lehrstuhl fuer Bauklimatik und Haustechnik

    2011-07-01

    Due to the mostly fluctuating feed-in characteristics, the strong expansion of renewable energy producers lets expect a paradigm shift in the structure of the power supply concept. The integration of renewables into the electricity grid requires new ways to compensate the temporal discrepancy between production and consumption. Such a load management or demand response requires electrical devices that can be varied with time in their mode of operation. The results of a feasibility study show that amongst other things a lot of electric devices being suitable for the implementation of the load management are present in office buildings and administration buildings. As an already existing communication structure one may refer to the equipment automation for the control of the individual devices. In order to realize the existing potentials, an innovative control strategy based on the existing hardware is necessary. This control strategy may adapt the mode of operation to an external signal. In order to allow a realistic development of such control strategies, a hardware-in-the-loop (HIL) testing environment was created which allows a development of control strategies by means of a real building automation controller under defined and reproducible conditions without adverse effects on the users of a building. The controller is connected to a personal computer which models the building and systems engineering taking into account the user behaviour in real time. All gates of the building automation are tapped and provided as input data to the simulation. Based on this information, in the simulation the reaction of the building is calculated for each time step. The current spatial conditions are reported back to the building automation. Thus, the controller can be tested with all the functionality in the HIL environment. Any locations and environmental conditions in the development process can be compared and evaluated by means of the simulation. The goal is to develop an

  5. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Science.gov (United States)

    Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608

  6. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Directory of Open Access Journals (Sweden)

    Ioannis A. Sakellaris

    2016-04-01

    Full Text Available Indoor environmental conditions (thermal, noise, light, and indoor air quality may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain. Occupants assessed indoor environmental quality (IEQ using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality, and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index, and building characteristics (office type and building’s location. Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  7. Lack of Energy Efficiency Legislation in the Malaysian Building Sector Contributes to Malaysia’s Growing GHG Emissions

    Directory of Open Access Journals (Sweden)

    Zaid Suzaini M.

    2014-01-01

    Full Text Available Malaysia’s carbon emissions grew by +235.6% from 1990 to 2005, largely due to an increase in national energy demand of 210.7% from 1990 to 2004. This unparalleled carbon emission growth, along with business-as-usual (BAU practices will put Malaysia at high risk for carbon lock-in and a very unsustainable path of development. Malaysia clearly needs to make significant and urgent changes in its policy, economy, industries and lifestyle in order to reduce its climate change impacts. In 2010 Malaysia announced a voluntary commitment to reduce 40% of its greenhouse gases (GHG emissions by 2020 (from 1990 levels. Without emissions mitigation and conservation policies, Malaysia is unlikely to meet its emissions reduction targets. Presently, Malaysia has no energy efficiency legislation in its growing building sector. This paper reviews existing building policies and energy efficiency measures in Malaysia and highlights the need to implement mandatory energy efficiency building codes in reducing the sector’s impact on climate change.

  8. Prevalence and risk factors for Sick Building Syndrome among Italian correctional officers: A pilot study

    Directory of Open Access Journals (Sweden)

    Francesco Chirico

    2017-03-01

    Full Text Available Introduction: Over the past two decades, numerous studies on indoor air and the Sick Building Syndrome (SBS have been conducted, mostly in office environments. However, there is little knowledge about SBS in police officers. This study was aimed to fill this gap. Methods: A cross-sectional questionnaire survey was conducted in 2016 at the Triveneto Penitentiary Center, Northern Italy. Chi-square was used to test the difference of prevalence between office workers (OWs and correctional officers (COs of personal characteristics, cases of SBS, and general and mucocutaneous symptoms associated with SBS. A binary logistic regression was used to identify among individual, environmental, and psychosocial characteristics, factors associated with correctional officers’ Sick Building Syndrome. Results: Chi-squared analyses revealed that there were statistically significant differences in the estimated prevalence of SBS general symptoms (χ2 (1 = 12.22, P < .05, SBS mucocutaneous symptoms (χ2 (1 = 9.04, P < .05, and cases of SBS (χ2 (1 = 4.39, P <.05 between COs and OWs. COs reported that their health had been affected by the passive smoking (β = 2.34, P < .05 and unpleasant odour (β = 2.51, P < .05 as environmental risk factors; work-family conflict (β = 2.14, P < .05, psychological and physical isolation (β = 2.07, P < .05, and negative public image (β = 2.06, P < .05 as psychosocial risk factors. Finally, atopy (β = 2.02, P < .05 and to be current smoker (β = 2.02, P < .05 were statistically significant behavioral predictors of SBS among correctional officers. Discussion: Our survey showed that symptoms compatible with the sick building syndrome are common in correctional officers and that psychosocial work climate and exposure to passive smoking could have a strong influence on the prevalence of both general and mucocutaneous symptoms associated with SBS. A health policy for passive tobacco smoking within prisons, and for work-related stress

  9. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

    Science.gov (United States)

    Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E

    2010-02-01

    The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.

  10. Human Perception, SBS Sympsoms and Performance of Office Work during Exposure to Air Polluted by Building Materials and Personal Computers

    DEFF Research Database (Denmark)

    Bako-Biro, Zsolt

    The present thesis deals with the impact of polluted air from building materials and personal computers on human perception, Sick Building Syndrome (SBS) symptoms and performance of office work. These effects have been studies in a series of experiments that are described in two different chapter......, each of them with one type of pollution source.......The present thesis deals with the impact of polluted air from building materials and personal computers on human perception, Sick Building Syndrome (SBS) symptoms and performance of office work. These effects have been studies in a series of experiments that are described in two different chapters...

  11. Final report of the radiological release survey of Building 19 at the Grand Junction Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 19 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  12. Final report of the radiological release survey of Building 11 at the Grand Junction Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 11 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  13. Final report of the radiological release survey of Building 29 at the Grand Junction Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailing during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 29 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  14. Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers

    Energy Technology Data Exchange (ETDEWEB)

    Stetiu, Corina [Univ. of California, Berkeley, CA (United States)

    1998-01-01

    Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

  15. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    Energy Technology Data Exchange (ETDEWEB)

    Ni Honggang; Cao Shanping; Chang Wenjing [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Zeng Hui, E-mail: huizeng0608@gmail.com [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Department of Ecology, College of Urban and Environmental Sciences, Peking University, Beijing 100871 (China)

    2011-07-15

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM{sub 2.5} (Particulate Matter up to 2.5 {mu}m in size) bounded {Sigma}{sub 15}PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM{sub 10} (Particulate Matter up to 10 {mu}m in size) bounded {Sigma}{sub 15}PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of {Sigma}{sub 15}PBDEs via dust inhalation and ingestion for adults reached {approx}141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: > Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. > PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. > The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. > Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  16. Energy performance modelling and heat recovery unit efficiency assessment of an office building

    Directory of Open Access Journals (Sweden)

    Harmati Norbert L.

    2015-01-01

    Full Text Available This paper investigates and analyzes a typical multi-zone office building’s annual energy performance for the location and climate data of central Belgrade. The aim is to evaluate the HVAC system’s and HR unit’s performance in order to conduct the most preferable heating and cooling solution for the typical climate of Belgrade city. The energy performance of four HVAC system types (heat pump - air to air, gas-electricity, electrical and fan coil system was analyzed, compared and evaluated on a virtual office building model in order to assess the total annual energy performance and to determine the efficiency of the HR unit’s application. Further, the parameters of an energy efficient building envelope, HVAC system, internal loads, building operation schedules and occupancy intervals were implemented into the multi-zone analysis model. The investigation was conducted in EnergyPlus simulation engine using system thermodynamic algorithms and surface/air heat balance modules. The comparison and evaluation of the obtained results was achieved through the conversion of the calculated total energy demand into primary energy. The goal is conduct the most preferable heating and cooling solution (Best Case Scenario for the climate of Belgrade city and outline major criteria in qualitative enhancement.

  17. Condensation Risk Due to Variations in Airtightness and Thermal Insulation of an Office Building in Warm and Wet Climate

    National Research Council Canada - National Science Library

    Cho, Wanghee; Iwamoto, Shizuo; Kato, Shinsuke

    2016-01-01

    .... By using TRNSYS simulation coupled with TRNFLOW, condensation assessment of an entire office building in Tokyo, Japan, was conducted throughout the year, including when the air-conditioning system...

  18. Louisiana State Lands and Buildings, Geographic NAD83, LA State Land Office (2007) [slabs_slo_2007

    Data.gov (United States)

    Louisiana Geographic Information Center — This dataset represents land and/or building areas for the state of Louisiana. This dataset was compiled by the State Land Office from Historical Records (SLABS)...

  19. Cost-benefit analysis of improved air quality in an office building

    DEFF Research Database (Denmark)

    Djukanovic, R.; Wargocki, Pawel; Fanger, Povl Ole

    2002-01-01

    A cost-benefit analysis of measures to improve air quality in an existing air-conditoned office building (11581 m2, 864 employees) was carried out for hot, temperate and cold climates and for two operating modes: Variable Air Volume (VAV) with economizer; and Constant Air Volume (CAV) with heat...... recovery. The annual energy cost and first cost of the HVAC system were calculat4ed using DOE 2.1E for different levels of air quality (10-50% dissatisfied). This was achieved by changing the outdoor air supply rate and the pollution loads. Previous studies have documented a 1.1% increase in office...... productivity for every 10% reduction in the proportion of occupants entering a space who are dissatisfied with the air quality. With this assumption, the annual benefit due to improved air quality was always at least 10 times higher than the increase in annual energy and maintenance costs. The payback time...

  20. Cost-benefit analysis of improved air quality in an office building

    DEFF Research Database (Denmark)

    Djukanovic, R.; Wargocki, Pawel; Fanger, Povl Ole

    2002-01-01

    productivity for every 10% reduction in the proportion of occupants entering a space who are dissatisfied with the air quality. With this assumption, the annual benefit due to improved air quality was always at least 10 times higher than the increase in annual energy and maintenance costs. The payback time......A cost-benefit analysis of measures to improve air quality in an existing air-conditoned office building (11581 m2, 864 employees) was carried out for hot, temperate and cold climates and for two operating modes: Variable Air Volume (VAV) with economizer; and Constant Air Volume (CAV) with heat...... recovery. The annual energy cost and first cost of the HVAC system were calculat4ed using DOE 2.1E for different levels of air quality (10-50% dissatisfied). This was achieved by changing the outdoor air supply rate and the pollution loads. Previous studies have documented a 1.1% increase in office...

  1. Energy Edge Post-Occupancy Evaluation Project: The Dubal/Beck Office Building Portland, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    The Workspace Satisfaction Survey measures occupant satisfaction with the thermal, lighting, acoustical, and air quality aspects of the work environment. In addition, to ratings of these ambient environmental features, occupants also rate their satisfaction with a number of functional aesthetic features of the office environment as well as their satisfaction with specific kinds of workspaces (e.g., computer rooms, the lobby, employee lounge, etc.) Each section on ambient conditions includes questions on the frequency with which people experience particular kinds of discomforts or problems, how much the discomfort bothers them, and how much it interferes with their work. Occupants are also asked to identify how they cope with discomfort or environmental problems, and to what extent these behaviors enable them to achieve more satisfactory conditions. This report documents the results of this survey of the occupants of the Dubal/Beck Office building, Portland, Oregon. 21 figs., 8 tabs.

  2. Architectural qualities of Danish office buildings built between 1960 and 1980, seen in a contemporary sustainable perspective

    DEFF Research Database (Denmark)

    Hannoudi, L.; Lauring, M.; Christensen, Jørgen Erik

    This study is about evaluating the past and present architectural quality of office buildings built between1960 and 1980 in Denmark. The evaluation will focus on the expression of these buildings in relation to their context, combined with the present sustainable performance of the buildings......, mould and fungus, and lack of tightness. The analysis of the originally intended architectural quality combined with current constructional, sustainable and aesthetic evaluation forms the basis for a discussion on the possibilities of implementing sustainable solutions in the office buildings...... and their critical problems. The initial method is a historical study to define the originally intended architectural quality of the office buildings and the different aspects related to this quality. The architectural quality is studied in relation to the societal and technological processes that characterized...

  3. Architectural qualities of Danish office buildings built between 1960 and 1980, seen in a contemporary sustainable perspective

    DEFF Research Database (Denmark)

    Hannoudi, L.; Lauring, M.; Christensen, Jørgen Erik

    2016-01-01

    This study is about evaluating the past and present architectural quality of office buildings built between1960 and 1980 in Denmark. The evaluation will focus on the expression of these buildings in relation to their context, combined with the present sustainable performance of the buildings...... and their critical problems. The initial method is a historical study to define the originally intended architectural quality of the office buildings and the different aspects related to this quality. The architectural quality is studied in relation to the societal and technological processes that characterized......, mould and fungus, and lack of tightness. The analysis of the originally intended architectural quality combined with current constructional, sustainable and aesthetic evaluation forms the basis for a discussion on the possibilities of implementing sustainable solutions in the office buildings...

  4. A Non-linear Stochastic Model for an Office Building with Air Infiltration

    DEFF Research Database (Denmark)

    Thavlov, Anders; Madsen, Henrik

    2015-01-01

    This paper presents a non-linear heat dynamic model for a multi-room office building with air infiltration. Several linear and non-linear models, with and without air infiltration, are investigated and compared. The models are formulated using stochastic differential equations and the model...... parameters are estimated using a maximum likelihood technique. Based on the maximum likelihood value, the different models are statistically compared to each other using Wilk's likelihood ratio test. The model showing the best performance is finally verified in both the time domain and the frequency domain...

  5. Innovative two-pipe active chilled beam system for simultaneous heating and cooling of office buildings

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Afshari, Alireza; Bergsøe, Niels Christian;

    2014-01-01

    energy between zones with one hydronic circuit, operating with a water temperature between 20°C and 23°C. To calculate the energy performance of the system, simulation-based research was developed. The two-pipe system was modelled by using EnergyPlus, a whole building energy simulation program. Hourly......The aim of this paper was to investigate the energy savings potential of an innovative two-pipe system in an active chilled beam application for heating and cooling of office buildings. The characteristic of the system is its ability to provide simultaneous heating and cooling by transferring...... heating, cooling and ventilation loads were calculated by the program and an annual energy consumption evaluation of the system was made. Simulation results showed that the innovative two-pipe active chilled beam system used approximately 5% less energy than a conventional four-pipe system....

  6. Two-Pipe Chilled Beam System for Both Cooling and Heating of Office Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Gordnorouzi, Rouzbeh; Hultmark, Göran;

    2013-01-01

    advantage of renewable energy. The results showed that the energy consumption was 3% less in the 2-pipe chilled beam system in comparison with the conventional 4-pipe system when moving cooled and heated water through the building, transferring the energy to where it is needed. Using free cooling (taking...... consumption and hence energy savings in the 2-pipe chilled beam system in comparison with the 4-pipe system. The 2-pipe chilled beam system used high temperature cooling and low temperature heating with a water temperature of 20°C to 23°C, available for free most of the year. The system can thus take......Simulations were performed to compare a conventional 4-pipe chilled beam system and a 2-pipe chilled beam system. The objective was to establish requirements, possibilities and limitations for a well-functioning 2-pipe chilled beam system for both cooling and heating of office buildings...

  7. Development of a new controller for simultaneous heating and cooling of office buildings

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Afshari, Alireza; Hultmark, Göran;

    2016-01-01

    with a temperature of about 22 °C. Therefore, the same supply water temperature is delivered to all the thermal zones in the building, no matter whether a single zone needs heating or cooling. In previous studies, the supply water temperature varied between 20 °C and 23 °C, according to outdoor air temperature......This paper aims to develop a new controller to regulate the supply water temperature of a room-temperature loop integrated in a novel HVAC for office buildings. The main feature of the room-temperature loop is its ability to provide simultaneous heating and cooling by circulating water...... by signals of actual room air temperatures and return water temperature. Depending on the minimum and maximum air temperatures in the rooms, the supply water temperature was set by adjusting the return water temperature with two offsets, one for heating demand and one for cooling demand. The behaviour...

  8. Final report of the radiological release survey of Building 54 at the Grand Junction Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 54 and the underlying soil were found not to be radiologically contaminated, and can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual release report for each GJO building.

  9. Technical Support Document: Strategies for 50% Energy Savings in Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.; Lobato, C.; Hirsch, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document (TSD) documents technical analysis that informs design guidance for designing and constructing large office buildings that achieve 50% net site energy savings over baseline buildings defined by minimal compliance with respect to ANSI/ASHRAE/IESNA Standard 90.1-2004. This report also represents a step toward developing a methodology for using energy modeling in the design process to achieve aggressive energy savings targets. This report documents the modeling and analysis methods used to identify design recommendations for six climate zones that capture the range of U.S. climate variability; demonstrates how energy savings change between ASHRAE Standard 90.1-2007 and Standard 90.1-2004 to determine baseline energy use; uses a four-story 'low-rise' prototype to analyze the effect of building aspect ratio on energy use intensity; explores comparisons between baseline and low-energy building energy use for alternate energy metrics (net source energy, energy emissions, and energy cost); and examines the extent to which glass curtain construction limits achieve energy savings by using a 12-story 'high-rise' prototype.

  10. To Investigate the Influence of Building Envelope and Natural Ventilation on Thermal Heat Balance in Office Buildings in Warm and Humid Climate

    Science.gov (United States)

    Kini, Pradeep G.; Garg, Naresh Kumar; Kamath, Kiran

    2017-07-01

    India’s commercial building sector is witnessing robust growth. India continues to be a key growth market among global corporates and this is reflective in the steady growth in demand for prime office space. A recent trend that has been noted is the increase in demand for office spaces not just in major cities but also in smaller tier II and Tier III cities. Growth in the commercial building sector projects a rising trend of energy intensive mechanical systems in office buildings in India. The air conditioning market in India is growing at 25% annually. This is due to the ever increasing demand to maintain thermal comfort in tropical regions. Air conditioning is one of the most energy intensive technologies which are used in buildings. As a result India is witnessing significant spike in energy demand and further widening the demand supply gap. Challenge in India is to identify passive measures in building envelope design in office buildings to reduce the cooling loads and conserve energy. This paper investigates the overall heat gain through building envelope components and natural ventilation in warm and humid climate region through experimental and simulation methods towards improved thermal environmental performance.

  11. Rivergate. Vienna office building of Auer+Weber+Assoziierte; Rivergate. Buerogebaeude in Wien von Auer+Weber+Assoziierte

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2009-05-15

    The new ''Rivergate'' office building in Vienna incorporates innovative energy concepts. It is heated with geothermal heat. There is a wide passage through the building as well as a footbridge connecting it directly with the underground railway and the right bank of the Danube river. (orig.)

  12. Method for Cost-Benefit Analysis of Improved Indoor Climate Conditions and Reduced Energy Consumption in Office Buildings

    Directory of Open Access Journals (Sweden)

    Viktoras Dorosevas

    2013-09-01

    Full Text Available Indoor climate affects health and productivity of the occupants in office buildings, yet in many buildings of this type indoor climate conditions are not well-controlled due to insufficient heating or cooling capacity, high swings of external or internal heat loads, improper control or operation of heating, ventilation and air conditioning (HVAC equipment, etc. However, maintenance of good indoor environmental conditions in buildings requires increased investments and possible higher energy consumption. This paper focuses on the relation between investment costs for retrofitting HVAC equipment as well as decreased energy use and improved performance of occupants in office buildings. The cost-benefit analysis implementation algorithm is presented in this paper, including energy survey of the building, estimation of occupants dissatisfied by key indoor climate indicators using questionnaire survey and measurements. Technique for Order Preference by Similarity to Ideal Solution (TOPSIS analysis is used in the proposed method for data processing. A case study of an office building is presented in order to introduce an application example of the proposed method. Results of the study verify the applicability of the proposed algorithm and TOPSIS analysis as a practical tool for office building surveys in order to maximize productivity by means of cost efficient technical building retrofitting solutions.

  13. Design methodology and criteria for daylight and thermal comfort in nearly-zero energy office buildings in Nordic climate

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth

    The objective of this PhD thesis was to arrange for an integrated building design with respect to thermal comfort, daylighting and energy use, applicable for office buildings in Nordic climate. In order to achieve this, it is suggested that modelling of mean radiant temperature (MRT) should...

  14. Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings

    DEFF Research Database (Denmark)

    Hummelgarrd, John; Juhl, Peter; Sæbjörnsson, Kristian

    2005-01-01

    The indoor air quality and occupant satisfaction was studied in five mechanically ventilated and four naturally ventilated open-plan office buildings in Copenhagen, using a simplified assessment procedure. Temperature and the concentration of CO2 were monitored in 2-10 locations per office...... to evaluate the variation throughout the offices. A representative measurement point was subsequently selected and measurements of the same parameters were made during one week. All offices were monitored during the same week and occupant responses to the indoor environment were collected via the Internet...... on the same day within that week. The study indicated that occupants in naturally ventilated offices have a lower prevalence of symptoms than those in mechanically ventilated offices. Although the room air temperature varied more and the concentration of CO2 was higher in the naturally ventilated offices...

  15. Cold Thermal Storage and Peak Load Reduction for Office Buildings in Saudi Arabia

    Institute of Scientific and Technical Information of China (English)

    Nabil Y.Abdel-Shafi; Ramzy R.Obaid; Ibrahim M.Jomoah

    2014-01-01

    This paper involves the investigations of the chilled water and ice cold thermal storage technologies along with the associated operating strategies for the air conditioning (AC) systems of the typical office buildings in Saudi Arabia, so as to reduce the electricity energy consumption during the peak load periods. In Saudi Arabia, the extensive use of AC for indoor cooling in offices composes a large proportion of the annual peak electricity demand. The very high temperatures over long summer periods, extending from May to October, and the low cost of energy are the key factors in the wide and extensive use of air conditioners in the kingdom. This intense cooling load adds up to the requirement increase in the capacity of power plants, which makes them under utilized during the off-peak periods. Thermal energy storage techniques are one of the effective demand-side energy management methods. Systems with cold storage shifts all or part of the electricity requirement from peak hours to off-peak hours to reduce demand charges and/or take advantage of off-peak rates. The investigations reveal that the cold thermal energy storage techniques are effective from both technical and economic perspectives in the reduction of energy consumption in the buildings during peak periods.

  16. Assessment of fungal diversity in a water-damaged office building.

    Science.gov (United States)

    Green, Brett J; Lemons, Angela R; Park, Yeonmi; Cox-Ganser, Jean M; Park, Ju-Hyeong

    2017-04-01

    Recent studies have described fungal communities in indoor environments using gene sequencing-based approaches. In this study, dust-borne fungal communities were elucidated from a water-damaged office building located in the northeastern region of the United States using internal transcribed spacer (ITS) rRNA gene sequencing. Genomic DNA was extracted from 5 mg of floor dust derived from 22 samples collected from either the lower floors (n = 8) or a top floor (n = 14) of the office building. ITS gene sequencing resolved a total of 933 ITS sequences and was clustered into 216 fungal operational taxonomic units (OTUs). Analysis of fungal OTUs at the 97% similarity threshold showed a difference between the lower and top floors that was marginally significant (p = 0.049). Species richness and diversity indices were reduced in the lower floor samples compared to the top floor samples and there was a high degree of compositional dissimilarity within and between the two different areas within the building. Fungal OTUs were placed in the phyla Ascomycota (55%), Basidiomycota (41%), Zygomycota (3%), Glomeromycota (0.4%), Chytridiomycota (0.3%), and unassigned fungi (0.5%). The Ascomycota classes with the highest relative abundances included the Dothideomycetes (30%) and Eurotiomycetes (16%). The Basidiomycota consisted of the classes Ustilaginomycetes (14%), Tremellomycetes (11%), and Agaricomycetes (8%). Sequence reads derived from the plant pathogen Ustilago syntherismae were the most abundant in the analysis as were obligate Basidiomycota yeast species that accounted for 12% and 11% of fungal ITS sequences, respectively. ITS gene sequencing provides additional insight into the diversity of fungal OTUs. These data further highlight the contribution of fungi placed in the phylum Basidiomycota, obligate yeasts, as well as xerophilic species that are typically not resolved using traditional culture methods.

  17. Potential energy savings with exterior shades in large office buildings and the impact of discomfort glare

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Sabine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lee, Eleanor [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-04-01

    Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems. While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption

  18. The Analysis Of Capillary Tube System For Office Buildings In Africa. A Case Study Of Nigerian And Namibian Climate

    Directory of Open Access Journals (Sweden)

    Sulaiman Muhammad kabir

    2015-08-01

    Full Text Available The change in climate and the rise in energy rates have become a necessary consideration in the construction industry which has made architects and engineers to arise with improved building design concepts. A focus on creating a comfortable indoor climate in office buildings ensures productive working conditions for the users and reduces global warming. Specific climatic design principles are often disregarded when designing to create a comfortable indoor climate. Sustainable design methods in buildings has been replicated from one zone to another zone without adjustments which results to buildings that do not provide adequate comfort. Capillary tube system is used to provide a comfortable indoor climate for office buildings making an interesting use of geothermal energy. This paper aims to explain its principle using geothermal energy and the effect of climate on the use of this system in office buildings in Africa. A case study of Lagos state lying on the coast of the Atlantic Ocean which is challenged with high rise in sea level as a result of global warming in Nigeria and Windhoek in Namibia is to be taken into consideration as the business hub of its country. These regions comprises of many office buildings to facilitate the countries trade internationally and locally.

  19. Improving PAQ and comfort conditions in Spanish office buildings with passive climate control

    Energy Technology Data Exchange (ETDEWEB)

    Orosa, Jose A.; Baalina, A. [Departamento de Energia y P.M. Escuela Tecnica Superior de N. y M, Universidade da Coruna, Paseo de Ronda 51, P.C.:15011 A Coruna (Spain)

    2009-03-15

    Some researchers have demonstrated that passive moisture transfer between indoor air and hygroscopic structures has the potential to moderate variations of indoor air relative humidity and, thus, to improve comfort and PAQ [Simonson CJ, Salonvaara M, Ojalen T. The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air 2002; 12: 243-51; Simonson CJ, Salonvaara M, Ojalen T. Improving indoor climate and comfort with wooden structures. Espoo 2001. Technical Research Centre of Finland, VTT Publications 431.200p+app 91p]. The main objective of this study is to show the internal wall coating effect on indoor air conditions and, as a consequence of this, in comfort conditions and PAQ. In a previous paper [Orosa JA, Baalina A. Passive climate control in Spanish office buildings for long periods of time. Building and Environment 2008], we analysed the influence of permeable and impermeable materials on indoor air conditions, during the unoccupied period, in 25 office buildings in different seasons. Results obtained lead us to conclude that real coverings such as permeable, semi-permeable and impermeable types, present different behavioural patterns in indoor air conditions. Furthermore, we concluded that an absorbent structure will moderate relative humidity indoors. In this paper, we study this indoor relative humidity effect on local thermal discomfort, due to decreased respiratory cooling, and indoor ambience acceptability for the early hours of morning applying PD and Acc models [Toftum J, Jorgensen AS, Fanger PO. Upper limits for indoor air humidity to avoid uncomfortably humid skin. Energy and buildings 1998; 28: 1-13; Toftum J, Jorgensen AS, Fanger PO. Upper limits of air humidity for preventing warm respiratory discomfort. Energy and Buildings 1998; 28: 15-23] such as that proposed by Simonson et al. [The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air

  20. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings

    Directory of Open Access Journals (Sweden)

    Piers MacNaughton

    2015-11-01

    Full Text Available Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person, 30% enhanced ventilation, and 40 cfm/person and four different heating, ventilation and air conditioning (HVAC system strategies (Variable Air Volume (VAV with reheat and a Fan Coil Unit (FCU, both with and without an energy recovery ventilator. We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities. The same change in ventilation

  1. A two stories office building designed for the southern Brazilian climate

    Energy Technology Data Exchange (ETDEWEB)

    Costella, M. [Elemento 5 Bioclimatic and Environmental Design, Chapeco (Brazil)

    2009-07-01

    This paper reported on a study in which a 2-storey office building was constructed using traditional and contemporary techniques and technologies to provide acceptable summer and winter thermal comfort. The design included the use of passive and hybrid cooling and heating techniques to decrease cooling and heating energy consumption and to improve thermal comfort. The design guidelines were based on the climate in Chapeco, Brazil in terms of annual mean temperature, relative humidity, wind speed and cloudiness. Passive strategies that respond to climate were used in the design, including natural daylighting; natural ventilation; solar heating and thermal mass; shading devices; and green roofs. The relationships between buildings and outdoor spaces were also controlled in order to ensure a response to the different seasons. This study showed that an environmental design approach goes far beyond the quantification of energy consumption through the use of different materials or strategies. The occupant's thermal and psychological comforts were placed as the main issues to be addressed and not energy savings. Once completed, the building will be monitored to determine if the passive strategies are working. 4 refs., 14 figs.

  2. Experimental study on small group behavior and crowd dynamics in a tall office building evacuation

    Science.gov (United States)

    Ma, Yaping; Li, Lihua; Zhang, Hui; Chen, Tao

    2017-05-01

    It is well known that a large percentage of occupants in a building are evacuated together with their friends, families, and officemates, especially in China. Small group behaviors are therefore critical for crowd movement. This paper aims to study the crowd dynamic considering different social relations and the impacts of small groups on crowd dynamics in emergency evacuation. Three experiments are conducted in an 11-storey office building. In the first two experiments, all participants are classmates and know each other well. They are evacuated as individuals or pairs. In the third experiment, social relations among the participants are complex. Participants consist of 8 families, 6 lovers and several individuals. Space-time features, speed characteristics and density-speed relations for each experiment are analyzed and compared. Results conclude that small group behaviors can make positive impacts on crowd dynamics when evacuees know each other and are cooperative. This conclusion is also testified by four verified experiments. In the third experiment, speeds of evacuees are lowest. Small groups form automatically with the presence of intimate social relations. Small groups in this experiment slow down the average speed of the crowd and make disturbance on the crowd flow. Small groups in this case make negative impacts on the movement of the crowd. It is because that evacuees do not know each other and they are competitive to each other. Characteristics of different types of small groups are also investigated. Experimental data can provide foundational parameters for evacuation model development and are helpful for building designers.

  3. IMPACT ON THE APPLICATION OF INSULATION IN BUILDINGS TO ACHIEVE THERMAL COMFORT (A CASE STUDY: LAUSER OFFICE BUILDING IN BANDA ACEH

    Directory of Open Access Journals (Sweden)

    Nova Purnama Lisa

    2014-12-01

    Full Text Available From the results of research studies on the impact of the use of insulation in buildings, reducing solar radiation on buildings to improve indoor comfort by applying the Principles of radiation reduction in buildings naturally using insulation application that serves as an insulator against the building materials, use of thermal insulation in particular mounted on the roof of the building and the walls are located on second floor and the third floor Lauser office building, Calculate the cooling load for each room that was on second floor and the third floor based on the geographical location or position of the building, climate data, building material data , and the intensity of the spatial characteristics which include lighting, solar radiation, user activity and electrical appliances being used. The calculation is done with the help of Ecotech v.5, 2011. The location and position on the third floor of a building with a flat roof cast concrete, so that the heat absorbed by the platform, and two times greater than the amount of heat radiation is absorbed by the material in the direction of the light falling the sun is at an angle <30°C. The simulation results on the building with the addition of thermal insulation on all walls and the roof of the inside of the foam material ultrafolmadehid, without changing the model building and similar activities in accordance with the existing condition and the condition of the room using the air conditioner at a temperature of 18-26°C, indicating a decrease in cooling load signifinikan in any space reaches 40% of the total cooling load required on the lauser office building. Comparing the simulation results Ecotech temperature v.5 2011 with field measurements as a validation of the simulation results in order to achieve thermal comfort in buildings and can menggurangi use energy consumption in buildings and can be used as a reference in planning space-based conditioning systems energy efficient.

  4. The effects of vehicle emissions and nucleation events on vertical particle concentration profiles around urban office buildings

    Directory of Open Access Journals (Sweden)

    T. N. Quang

    2012-01-01

    Full Text Available Despite its role in determining both indoor and outdoor human exposure to anthropogenic particles, there is limited information describing vertical profiles of particle concentrations in urban environments, especially for ultrafine particles. Furthermore, the results of the few studies performed have been inconsistent. As such this study aimed to assess the influence of vehicle emissions and nucleation formation on particle concentrations (PN and PM2.5 at different heights around three urban office buildings located next to busy roads in Brisbane, Australia, and place these results in the broader context of the existing literature. Two sets of instruments were used to simultaneously measure PN size distribution, PN and PM2.5 concentrations, respectively, for up to three weeks each at three office buildings.

    The results showed that both PN and PM2.5 concentrations around building envelope were influenced by vehicle emissions and new particle formation, and that they exhibited variability across the three different office buildings. During the nucleation event, PN concentrations increased (21–46%, while PM2.5 concentrations decreased (36–52% with height at all three buildings.

    This study has shown an underappreciated role of nucleation in producing particles that can affect large numbers of people, due to the high density and occupancy of urban office buildings and the fact that the vast majority of people's time is spent indoors. These findings highlight important new information related to the previously overlooked role of particle formation in the urban atmosphere and its potential effects on selection of air intake locations and appropriate filter types when designing or upgrading mechanical ventilation systems in urban office buildings. The results also serve to better define particle behaviour and variability around building envelopes, which has implications for studies of

  5. Sustainable enterprise in office buildings of small businesses; Duurzaam ondernemen in het kantoorhoudende MKB

    Energy Technology Data Exchange (ETDEWEB)

    Bertens, C. [Panteia/EIM, Zoetermeer (Netherlands); Muizer, A. [Panteia/Consult, Zoetermeer (Netherlands)

    2012-05-15

    SMEs in the Netherlands will increasingly face stricter sustainability criteria in procurement procedures. A study has been carried out among 375 small businesses that will provide insight into the state of sustainability in office buildings of SMEs. Attention is paid to the importance of sustainability, measures taken with regard to sustainable enterprising, plans and ambitions; and required support [Dutch] Het MKB krijgt in toenemende mate te maken met strengere duurzaamheidseisen in aanbestedingsprocedures. Er is onderzoek gedaan onder 375 bedrijven waarmee inzicht wordt gegeven in de stand van zaken van duurzaam ondernemen in het kantoorhoudend MKB. Het gaat in grote lijnen om de volgende aspecten: het belang van duurzaam ondernemen; genomen maatregelen op het gebied van duurzaam ondernemen; plannen en ambities; benodigde ondersteuning.

  6. Solar heating and cooling system for an office building at Reedy Creek Utilities

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    This final report describes in detail the solar energy system installed in a new two-story office building at the Reedy Creek Utilities Company, which provides utility service to Walt Disney World at Lake Buena Vista, Florida. The solar components were partly funded by the Department of Energy under Contract EX-76-C-01-2401, and the technical management was by NASA/George C. Marshall Space Flight Center. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The collector is a modular cylindrical concentrator type with an area of 3.840 square feet. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled. Design, construction, operation, cost, maintenance, and performance are described in depth. Detailed drawings are included.

  7. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou

    2014-01-01

    The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied...... zone was 21.0°C for mixing ventilation and 20.8°C for displacement ventilation when supply air temperature was 19°C and air change rate was 4.2 h-. Vertical air temperature difference between the head level and the foot level were all less than 3°C and local air velocity were all less than 0.2m....../s for both ventilation systems. In addition, local ventilation effectiveness ranged from 0.91 to 0.94 for mixing ventilation and from 1.03 to 1.17 for displacement ventilation. Distributions of vertical air temperature and velocity and horizontal contaminant concentration were more uniform for mixing...

  8. Electrosmog prevention in office buildings. Frequency modulators prevent electrosmog; Raumentstoerung in Buerogebaeuden. Mit Frequenzmodulatoren gegen Elektrosmog

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, W. [Technische Gebaeudeausruestung, Muenchen (Germany)

    2002-07-01

    Experts agree that electrosmog is caused by radiocommunication, electronic and electric equipment at the place of work and call for minimisation of radiation. IPR Stuttgart, a subsidiary of Drees and Sommer, Stuttgart, reduces electrosmog in office buildings with the aid of frequency modulators. [German] Noch vor wenigen Jahren galt die Klimaanlage gemeinhin als Hauptverursacher von Muedigkeit, Kopfschmerzen und Konzentrationsschwaeche. Mit dem Trend zu Kuehldecken, Quell-Lueftung, Bauteiltemperierung und Oeko-Klimaanlagen hat die Akzeptanz raumlufttechnischer Anlagen spuerbar zugenommen. Viele buerotypischen Beschwerden sind allerdings geblieben. Experten sind sich darueber einig, dass dafuer in erster Linie Elektrosmog durch Mobilfunk, elektronische Geraete und Elektrosysteme verantwortlich sind und fordern eine Minimierung der Strahlenbelastung am Arbeitsplatz. Das Institut fuer physikalische Raumentstoerung (IPR), eine Tochtergesellschaft des Projektentwicklers Drees and Sommer, Stuttgart, hat sich jetzt zur Aufgabe gemacht, Gebaeude und deren technische Ausstattung mit Hilfe von Frequenzmodulatoren physikalischen zu entstoeren. (orig.)

  9. Are Biophilic-Designed Site Office Buildings Linked to Health Benefits and High Performing Occupants?

    Directory of Open Access Journals (Sweden)

    Tonia Gray

    2014-11-01

    Full Text Available This paper discusses the first phase of a longitudinal study underway in Australia to ascertain the broad health benefits of specific types of biophilic design for workers in a building site office. A bespoke site design was formulated to include open plan workspace, natural lighting, ventilation, significant plants, prospect and views, recycled materials and use of non-synthetic materials. Initial data in the first three months was gathered from a series of demographic questions and from interviews and observations of site workers. Preliminary data indicates a strong positive effect from incorporating aspects of biophilic design to boost productivity, ameliorate stress, enhance well-being, foster a collaborative work environment and promote workplace satisfaction, thus contributing towards a high performance workspace. The longitudinal study spanning over two years will track human-plant interactions in a biophilic influenced space, whilst also assessing the concomitant cognitive, social, psychological and physical health benefits for workers.

  10. Are biophilic-designed site office buildings linked to health benefits and high performing occupants?

    Science.gov (United States)

    Gray, Tonia; Birrell, Carol

    2014-11-26

    This paper discusses the first phase of a longitudinal study underway in Australia to ascertain the broad health benefits of specific types of biophilic design for workers in a building site office. A bespoke site design was formulated to include open plan workspace, natural lighting, ventilation, significant plants, prospect and views, recycled materials and use of non-synthetic materials. Initial data in the first three months was gathered from a series of demographic questions and from interviews and observations of site workers. Preliminary data indicates a strong positive effect from incorporating aspects of biophilic design to boost productivity, ameliorate stress, enhance well-being, foster a collaborative work environment and promote workplace satisfaction, thus contributing towards a high performance workspace. The longitudinal study spanning over two years will track human-plant interactions in a biophilic influenced space, whilst also assessing the concomitant cognitive, social, psychological and physical health benefits for workers.

  11. Assessment of the Fire Risk Levels in an Office Building and a Nightclub with Prescriptive Designs

    DEFF Research Database (Denmark)

    Yilmaz, D.; Steffensen, F.B.; Jomaas, Grunde

    2014-01-01

    was far from meeting the requirements. Another suggested tolerable level herein was derived from the UK specifications by the Health and Safety Executive, which distinguish between tolerable safety level for members of the public and for workplaces. This comparison made it even more difficult......A comparison of the risk level of an office building and a nightclub with code compliant prescriptive designs was conducted in order to evaluate whether an uniform safety level of the two occupancy types can be established. A risk assessment method using Monte Carlo simulations and 1- and 2-zone...... difference in risk levels, with that of the nightclub being substantially higher. The higher risk level in the nightclub is caused by a relatively fast mean value of the fire growth rate and the high number of occupants. Hence, the requirements in the prescriptive code do not ensure a similar safety level...

  12. Simplified prediction model for lighting energy consumption in office building scheme design

    Institute of Scientific and Technical Information of China (English)

    余琼; 周潇儒; 林波荣; 朱颖心

    2009-01-01

    At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful to develop a design guideline related to the evaluation of lighting energy saving potential and sunlight design strategies. This paper analyzes the impacts of different artificial lighting control methods and design parameters on daylighting. A direct correlation between lighting energy consumption and parameters such as orientations,window to wall ratio (WWR) and perimeter depth is established. A simplified prediction model is proposed to estimate lighting energy consumption with the given perimeter depth,WWR,and window transparency. Validation of the model is carried out compared with detailed lighting simulation software for an office building. After the variation analysis for these parameters,design advises for the daylighting design at scheme design phase are summarized.

  13. The energy savings potential of using dynamic external louvers in an office building

    Energy Technology Data Exchange (ETDEWEB)

    Hammad, Fawwaz [W.S. Atkins, Abu Dhabi (United Arab Emirates); Abu-Hijleh, Bassam [Atkins Chair, Faculty of Engineering, The British University in Dubai, PO Box 345015, Dubai (United Arab Emirates)

    2010-10-15

    This research is aimed at exploring the influence of external dynamic louvers on the energy consumption of an office building located in Abu Dhabi-UAE. The IES-VR software was used to predict the energy consumption of a representative office module in order to evaluate the overall energy performance of employing external louvers on the south, east and west oriented facades. The use of dynamic facades was compared to another simpler method of using light-sensor controlled light dimmers. The results show that the potential energy savings using light dimming strategy only was 24.4%, 24.45% and 25.19% for the south, east and west oriented facades, respectively. The proposed dynamic louvers system with light dimming strategy achieved energy savings of 34.02%, 28.57% and 30.31% for the south, east and west orientations, respectively. Detailed analysis of the results showed that the facade's optimal static angle was -20 for the south oriented facade and 20 for the east and west oriented facades. Using these fixed optimal angles resulted in slightly lower energy savings than that of the dynamic facades. This would seem to be a good tradeoff between savings in energy running cost and the investment required to install, operate and maintain a dynamic facades system. (author)

  14. The effects of reduced ventilation on indoor air quality in an office building

    Science.gov (United States)

    Turiel, I.; Hollowell, C. D.; Miksch, R. R.; Rudy, J. V.; Young, R. A.; Coye, M. J.

    Indoor air quality was monitored at an office building in San Francisco, CA where occupants had registered eye, nose and throat irritation complaints. Portable air pollution monitoring equipment was placed on site to monitor air outdoors and at three indoor sites (a waiting room, an interview room and an office room), and data were taken under two different ventilation rates. The parameters measured were outside air flow rates, temperature, relative humidity, odor perception, microbial burden, particulate mass, formaldehyde and other organics, carbon dioxide, carbon monoxide and nitrogen dioxide. Carbon dioxide concentrations increased as the ventilation rate decreased; odor perceptibility increased slightly at the lowest ventilation rate, and other pollutants generally showed very low concentrations, which increased when ventilation was reduced. In no case, however, did levels exceed current health standards for outdoor air, nor was any one contaminant found to be responsible for the medical symptoms reported by occupants. It is possible that a synergistic effect of the various contaminants and environmental conditions may account for the discomfort of occupants.

  15. CHARACTERIZATIONS AND RELATIONSHIPS BETWEEN OUTDOOR AND INDOOR BIOAEROSOLS IN AN OFFICE BUILDING

    Institute of Scientific and Technical Information of China (English)

    Hong Zhu; Patrick Phelan; Tianhua Duan; Gregory Raupp; H. J. S. Fernando

    2003-01-01

    Characterizations and relationships between indoor and outdoor bioaerosols were examined in an occupied office building, equipped with an air conditioning (HVAC) system, in Tempe, Arizona, USA. A two-stage microbial air sampler was used to collect bioaerosols both inside and outside the office at fixed locations in space and at regular time intervals from August to December, 2000. Simultaneous measurements of bioaerosol, temperature, relative humidity,light intensity and wind speed were performed to explore the effects of environmental factors on bioaerosol levels.Twenty species of airborne bacteria and four genera of airborne fungi were found in our samples. The particle sizes of most outdoor and indoor bioaerosols were larger than 8.0 μm. According to the measurements of sampling days, the concentrations of outdoor bioaerosols were highest in the morning, but declined in the afternoon and reached the lowest point in the evening. The concentration peak of indoor bioaerosol (especially at the lower level) occurred in the evening,suggesting that the concentration of indoor bioaerosols follows that of outdoors, but with a time delay due to the lag associated with indoor-outdoor air exchange. With regard to the effects of four environmental factors - temperature, relative humidity, light intensity, and wind speed, the relative humidity had the most pronounced influence on the outdoor bioaerosol concentrations with the number of bacteria and fungi increasing sharply on a day of high relative humidity in the desert area.

  16. Delivering a sustainable future for offices in Greece in the context of climate change: The case-study of a public office building

    Science.gov (United States)

    Giannikopoulos, Charalampos

    The iggo's has been the warmest decade globally leading to a dramatic climate change due to the j greenhouse effect and the consequent global warming. Allowing this trend to continue the planet is going to face a catastrophic climate change without precedent with various impacts. One of the most significant aims in the combat against climate change is the reduction of carbon dioxide and j other greenhouse gases emissions that are responsible for global warming. Under the Kyoto protocol, the developed countries need to reduce their GHGs emissions to 1990 levels by 2012. Energy consumption for building-related services in the European Union accounts for approximately 50% of the total energy consumption and the resulting C02 emissions (Richarz et al 2007). Hence, at first sight the best policy for a decrease is by improving the energy performance of new and existing buildings. The question to be solved, however, is which improvements at buildings could reduce energy consumption and accordingly C02 emissions In this context, the analysis of the energy consumption and the respective carbon emissions over a public large-scale existing office building in Greece can result in a comprehensive j understanding of how energy efficiency-upgrades can be critical when combating climate change. This analysis is made using thermal analysis software and extracting results about energy consumption that can be compared to the real data collected from the Building Energy Management System. Afterwards, potential improvements in the building envelope in terms of a more efficient control of solar gains are tested on the model and finally, photovoltaics are applied in order to generate zero-carbon electricity. The energy-efficiency upgrades suggested have achieved a total reduction in energy used for j heating and cooling by 11.9%, with the reduction in cooling far exceeding the respective reduction in heating. Consequently, 193 MWh that are equivalent to 117 tons of C02 are saved annually

  17. Energy Refurbishment of an Office Building with Hybrid Photovoltaic System and Demand-Side Management

    Directory of Open Access Journals (Sweden)

    Giovani Almeida Dávi

    2017-08-01

    Full Text Available On-site photovoltaic (PV and battery systems intend to improve buildings energy performance, however battery costs and monetary incentives are a major drawback for the introduction of these technologies into the electricity grids. This paper proposes an energy refurbishment of an office building based on multi-objective simulations. An innovative demand-side management approach is analyzed through the PV and battery control with the purpose of reducing grid power peaks and grid imported energy, as well as improving the project economy. Optimization results of load matching and grid interaction parameters, complemented with an economic analysis, are investigated in different scenarios. By means of battery use, the equivalent use of the grid connection is reduced by 12%, enhancing the grid interaction potential, and 10% of load matching rates can be increased. Project improvements indicate the grid connection capacity can be reduced by 13% and significant savings of up to 48% are achieved on yearly bills. The economy demonstrates the grid parity is only achieved for battery costs below 100 €/kWh and the payback period is large: 28 years. In the case with only PV system, the grid parity achieves better outcomes and the payback time is reduced by a half, making this a more attractive option.

  18. The Ares Projects Office: Building an Exploration Culture from the Inside Up

    Science.gov (United States)

    Leahy, Bartholomew

    2008-01-01

    NASA is building its first new human-rated space exploration vehicles in nearly 40 years. This marks an important operational and cultural change from the Space Shuttle. In the wake of the Columbia disaster, the agency and the nation realized that NASA's goals and culture needed to change. The Ares Projects Office (APO), which is building the launch vehicles that will power human beings to the Moon, Mars, and beyond, is taking a page from the Saturn playbook by having NASA lead both the overall integration and the development of the Ares I upper stage. APO is also creating a new culture of cooperation, openness, and informed risk taking as we set our sights on other worlds. APO has established a team environment where issues can be discussed, information is shared, fun and teamwork are encouraged, and constructive conflict and accountability are expected. Following a "One NASA" philosophy, APO is taking steps to strengthen cooperation among space centers, contractor partners, engineering and scientific communities, and headquarters personnel. As we learn lessons from things that Went wrong with the Space Shuttle, we are also borrowing best practices from what has gone right with that program and others. All of these cultural elements will be necessary as we take the next steps beyond Earth orbit.

  19. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

    Science.gov (United States)

    1980-01-01

    A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

  20. Energy efficiency: implemented strategies in the new building for regional Government Offices in Mérida (Spain)

    OpenAIRE

    Fairbanks, Bruce S.; Montero, Eduardo

    2007-01-01

    The architecture office GOP was awarded the execution of the project for the regional government office building “Consejerías”) in the city of Mérida, designed by Bruce S. Fairbanks, through an International Competition of Ideas summoned by the Junta de Extremadura. The new Consejerías in Mérida set the standards for a wholly sustainable building. It modifies its natural outdoors environment by soothing the climate and giving shelter. A design strategy was, among others, to gain as much conf...

  1. Architectural qualities of Danish office buildings built between 1960 and 1980, seen in a contemporary sustainable perspective

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Lauring, Michael; Christensen, Jørgen Erik

    This study is about evaluating the past and present architectural quality of office buildings built between1960 and 1980 in Denmark. The evaluation will focus on the expression of these buildings in relation to their context, combined with the present sustainable performance of the buildings......, mould and fungus, and lack of tightness. The analysis of the originally intended architectural quality combined with current constructional, sustainable and aesthetic evaluation forms the basis for a discussion on the possibilities of implementing sustainable solutions in the office buildings....... This implementation will have an impact on the aesthetic output, and the concepts of possible contemporary architectures are highlighted. Keywords: architectural quality, sustainable performance, modernism, industrialization, environment, aesthetic aspects, economic, comfort problems, durability and rationality....

  2. Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings

    DEFF Research Database (Denmark)

    Hummelgaard, J.; Juhl, P.; Saebjornsson, K.O.

    2007-01-01

    afternoon. In a pre-experiment, temperature and the concentration Of CO2 were monitored in 2-10 locations/office to evaluate the variation throughout the offices. A representative measurement point was subsequently selected and measurements of the same parameters were made during one week. All offices were...... monitored during the same week and occupant responses to the indoor environment were collected via the internet on the same day within that week. The temperature and the CO2 concentration varied more and were in some cases higher in the naturally ventilated buildings, but occupant responses in terms...

  3. Commercial-sector energy-consumption data-base-development project. Volume III. Analysis of energy consumption in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-04-01

    Results are presented of an effort to develop comprehensive and reliable energy consumption data for office buildings. A survey was conducted of readily available energy consumption data and the literature that describes the factors which drive energy use in such buildings was analyzed. Information on heating, ventilating, and air conditioning (HVAC) systems was assembled. A number of building energy use simulation programs were reviewed to determine their suitability for estimating energy consumption by function and the effects of tradeoffs in building design and operating parameters on building energy use. Simulations using the AXCESS program were conducted. The 1975 data base of the Building Owners and Managers Association (BOMA) was obtained and analyzed. Data describing energy use on a regional and national basis were developed, and regression equations based on these were obtained. The ability of these equations to predict average energy use was then confirmed by applying them to four office buildings not in the BOMA data base. A number of proposals for the further improvement of the equations were developed, including additional data collection. Specifically, the survey of actual and simulated data on a regional basis is reported in Section 2. HVAC systems are discussed in Sections 3 and 4. BOMA obtains annual data on about 1000 buildings covering such items as location, floor area, height, age, average occupancy rate, average number of employees, types of tenants, type of air conditioning, and energy consumption by fuel and the description and analyses of the BOMA data are presented in Sections 5 and 6.

  4. Solar and Lighting Transmission through Complex Fenestration Systems of Office Buildings in a Warm and Dry Climate of Chile

    Directory of Open Access Journals (Sweden)

    Waldo Bustamante

    2014-05-01

    Full Text Available Overheating, glare, and high-energy demand are recurrent problems in office buildings in Santiago, Chile (33°27'S; 70°42'W during cooling periods. Santiago climate is warm and dry, with high solar radiation and temperature during most of the year. The objective of this paper is to evaluate the thermal and daylighting performance of office buildings transparent façades composed of three different complex fenestration systems (CFS. Each CFS contains a different external shading device (ESD: (1 external roller, (2 vertical undulated and perforated screens, and (3 tilted undulated and perforated screens. The study was carried out by in situ monitoring in three office buildings in Santiago, Chile. Buildings were selected from a database of 103 buildings, representing those constructed between 2005 and 2011 in the city. The monitoring consisted of measuring the short wave solar and daylighting transmission through fenestration systemsby means of pyranometers and luxometers, respectively. This paper shows measurements that were carried out during summer period. A good performance is observed in a building with the external roller system. This system—applied to a northwest façade—shows a regular and high solar and daylighting control of incoming solar radiation. The other two ESD systems evidence a general good performance. However, some deficiencies at certain times of the day were detected, suggesting a non-appropriated design.

  5. 某大型办公建筑能耗分析%Energy Consumption of a Large Office Building

    Institute of Scientific and Technical Information of China (English)

    张晓转; 张明顺; 吴川

    2014-01-01

    Energy audit is the foundation of building energy efficiency in which the large office build-ing energy efficiency is very important. By the method of energy audit, the energy structure and energy uti-lization character of an office building in Beijing is analyzed, and the energy characteristics of office build-ing are summarized. The most energy consumption is devoted to the air conditioning and heating system, followed by lighting system. The specific countermeasures are proposed for energy efficiency of each sys-tem.%大型办公建筑是建筑节能改造的重点领域,能源审计是建筑节能的基础。通过能源审计的方法,对北京某办公楼的能源结构和能源利用特点进行分析,总结了办公建筑的用能特点,办公楼的最大用能系统为空调和采暖系统;其次为照明系统,并针对该建筑各用能系统的情况提出具体的节能对策。

  6. US Department of Energy Grand Junction Projects Office Remedial Action Project, final report of the decontamination and decommissioning of Building 36 at the Grand Junction Projects Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. Building 36 was found to be radiologically contaminated and was demolished in 1996. The soil beneath the building was remediated in accordance with identified standards and can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  7. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document

  8. Light Pipe Transporter for High-rise Office Building in Tropical Climate

    Directory of Open Access Journals (Sweden)

    Christopher Yii Sern Heng

    2016-01-01

    Full Text Available Daylight has known to bring benefits for human, psychologically and physiologically. It also provides better indoor environment quality and thus increase the performance and productivity of office workers as stated by Paevere (2009. However, due to economic reasons, the current practice of using deep open plan building has cause a dent to having daylight in the interior spaces, which cause a dependency on artificial lighting. Hence, to provide daylight in deep interior, light distribution system is needed. Although so, according to Hansen (2003, most of the systems can only illuminate up to 8m-10m depth. Therefore, light pipe (LP plays an essential role where it can illuminate up to 20m depth. LP’s efficiency depends on the 3 main components; collector, transporter and extractor. This research explores the effectiveness of horizontal LP through different type of transporter’s shapes which includes rectangular, triangular, square and semi-circle. Previous studies have shown differences of efficiency on the shaped while using vertical LP. This research’s analysis was done using a computer simulation, Integrated Environment Solution: Virtual Environment (IESVE, where DF of each shapes were compared to MS 1525:2007 benchmark. The viability of the software was also validated though an assessment with a physical scaled-model experiment that was conducted in an open car park in Universiti Teknologi Malaysia, Johor, Malaysia. The results from the simulation showed that semi-circle shaped transporter offered the same efficiency as rectangular shaped. These findings will promote the usage of LP in buildings as it decreases the costing for LP.

  9. Analyses of IEQ and user satisfaction in 20 office buildings : significant findings to impact future design standards and guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J.; Loftness, V.; Aziz, A. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Centre for Building Performance and Diagnostics

    2009-07-01

    This paper reported on a field study that provided supportive ideas for environmental standards and design guidelines for office environments which could satisfy indoor environmental quality (IEQ) requirements. IEQ is an important variable affecting occupant health, productivity as well as organization success. As such, occupant comfort and satisfaction must be ensured for each component of IEQ, notably thermal quality, air quality, lighting quality, and noise. In partnership with the General Services Administration, the Center for Building Performance and Diagnostics research team at Carnegie Mellon conducted a post-occupancy evaluation field study of 20 commercial office buildings throughout the United States. The objective and subjective data of IEQ obtained from the study were used for correlational analysis. The study results provide evidences to modify office environmental design guideline to improve physiological and environmental benefits. 5 refs., 1 tab., 10 figs.

  10. Condensation Risk Due to Variations in Airtightness and Thermal Insulation of an Office Building in Warm and Wet Climate

    Directory of Open Access Journals (Sweden)

    Wanghee Cho

    2016-10-01

    Full Text Available Condensation in a building encourages microbial growth, which can have an adverse effect on the health of occupants. Furthermore, it induces the deterioration of the building. To prevent problems caused by condensation, from the design step of a building, predictions of the spatial, temporal and causation for condensation occurrences are necessary. By using TRNSYS simulation coupled with TRNFLOW, condensation assessment of an entire office building in Tokyo, Japan, was conducted throughout the year, including when the air-conditioning system was not operated, by considering the absorption-desorption properties of the building materials and papers in the office and the airflow within the entire building. It was found that most of the condensation occurred during winter and was observed mainly in the non-air-conditioned core parts, especially the topmost floor. Additional analyses, which identified the effect of variations in the thermal insulation of the external walls, roof and windows and the airtightness of the windows on condensation, showed that the lower airtightness of windows resulted in decreased condensation risks, and condensation within the building was suppressed completely when the thermal insulation material thickness of the external walls was greater than 75 mm, that of the roof was greater than 105 mm and the windows had triple float glass.

  11. Simulation of energy use, human thermal comfort and office work performance in buildings with moderately drifting operative temperatures

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Olesen, Bjarne W.

    2011-01-01

    ) supplemented with CAV ventilation. Simulations comprised moderate, hot–dry and hot–humid climate. Heavy and light wall construction and two orientations of the building (east–west and north–south) were considered. Besides the energy use, also capability of examined systems to keep a certain level of thermal......Annual primary energy use in a central module of an office building consisting of two offices separated with a corridor was estimated by means of dynamic computer simulations. The simulations were conducted for conventional all-air VAV ventilation system and thermo active building system (TABS...... comfort was examined. The results showed that with the moderate climate, the TABS decreased the primary energy use by about 16% as compared with the VAV. With hot–humid climate, the portion of the primary energy saved by TABS was ca. 50% even with the supply air dehumidification taken into account...

  12. Overall efficiency of office buildings; Gesamtenergieeffizienz von Buero-Bauten. Optimierung des Heizwaermebedarfs vs. Optimierung der Gesamtenergieeffizienz - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Gadola, R.; Menti, U.-P.; Pluess, I.; Klauz, S. [Hochschule Luzern - Technik und Architektur Zentrum fuer Integrale Gebaeudetechnik (ZIG), Horw (Switzerland); Menard, M. [Lemon Consult GmbH, Zuerich (Switzerland)

    2010-04-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at the overall efficiency of office buildings. The optimisation of heating requirements and the optimisation of overall energy efficiency are compared. The trend towards compact, very well insulated buildings as propagated by current energy regulations is examined in the light of other energy-saving aspects such as air-conditioning requirements and lighting. The Swiss 'Minergie-P' standard that calls for extremely low energy consumption is discussed in this connection. Primary energy requirements and greenhouse gas emissions are discussed and sensitivity analyses for various factors affecting buildings are looked at. Also 'grey energy' in materials is considered.

  13. Real-Time Occupant Based Plug-in Device Control Using ICT in Office Buildings

    Directory of Open Access Journals (Sweden)

    Woo-Bin Bae

    2016-03-01

    Full Text Available The purpose of this study is to reduce the unnecessary plug loads used by computers, monitors, and computer peripheral devices, all of which account for more than 95% of the entire plug loads of an office building. To this end, an occupant-based plug-in device control (OBC-P software was developed. The OBC-P software collects real-time information about the presence or absence of occupants who are connected to the access point through the Wifi and controls the power of monitors or computers, while a standby power off device controls computer peripheral devices. To measure the plug load saving of the occupant-based plug-in device control, an experiment was conducted, targeting 10 occupants of three research labs of the graduate school, for two weeks. The experiment results showed that it could save the plug loads of monitors and computer peripheral devices by 15% in the Awake mode, and by 26% in the Sleep mode.

  14. Life Cycle Assessment of Flat Roof Technologies for Office Buildings in Israel

    Directory of Open Access Journals (Sweden)

    Svetlana Pushkar

    2016-01-01

    Full Text Available The goal of the current study was to evaluate the environmental damage from three flat roof technologies typically used in Israel: (i concrete, (ii ribbed slab with concrete blocks, and (iii ribbed slab with autoclaved aerated blocks. The roofs were evaluated using the Life Cycle Assessment (LCA methodology. The Production and Construction (P and C, Operational Energy (OE, and Maintenance to Demolition (MtoD stages were considered. The roofs were modeled based on an office building module located in the four climate zones of Israel, and the hierarchical ReCiPe2008 Life Cycle Impact Assessment (LCIA method was applied. The percent difference of one, which is the default methodological option of ReCiPe2008, and an ANOVA of the six methodological options of ReCiPe2008 were used. The results revealed that (i in a hot climate, the best roof technology can be selected by considering only the OE stage, whereas in a mild climate, both the OE and P and C stages must be considered; (ii in a hot climate, the best roof technology is a concrete roof, but in a mild climate, the best options are ribbed slab roofs with concrete blocks and autoclaved aerated blocks; and (iii the conjugation of ReCiPe2008 with a two-stage nested ANOVA is the appropriate approach to evaluate the differences in environmental damage in order to compare flat roof technologies.

  15. A non-linear stochastic model for an office building with air infiltration

    Directory of Open Access Journals (Sweden)

    Anders Thavlov

    2015-06-01

    Full Text Available This paper presents a non-linear heat dynamic model for a multi-room office building with air infiltration. Several linear and non-linear models, with and without air infiltration, are investigated and compared. The models are formulated using stochastic differential equations and the model parameters are estimated using a maximum-likelihood technique. Based on the maximum-likelihood value, the different models are statistically compared to each other using Wilk's likelihood ratio test. The model showing the best performance is finally verified in both the time domain and the frequency domain using the auto-correlation function and cumulated periodogram. The proposed model which includes air-infiltration shows a significant improvement compared to previously proposed linear models. The model has subsequently been used in applications for provision of power system services, e.g. by providing heat load reduction during peak load hours, control of indoor air temperature and for generating forecasts of power consumption from space heating.

  16. Daylight Design of Office Buildings: Optimisation of External Solar Shadings by Using Combined Simulation Methods

    Directory of Open Access Journals (Sweden)

    Javier González

    2015-05-01

    Full Text Available Integrating daylight and energy performance with optimization into the design process has always been a challenge for designers. Most of the building environmental performance simulation tools require a considerable amount of time and iterations for achieving accurate results. Moreover the combination of daylight and energy performances has always been an issue, as different software packages are needed to perform detailed calculations. A simplified method to overcome both issues using recent advances in software integration is explored here. As a case study; the optimization of external shadings in a typical office space in Australia is presented. Results are compared against common solutions adopted as industry standard practices. Visual comfort and energy efficiency are analysed in an integrated approach. The DIVA (Design, Iterate, Validate and Adapt plug-in for Rhinoceros/Grasshopper software is used as the main tool, given its ability to effectively calculate daylight metrics (using the Radiance/Daysim engine and energy consumption (using the EnergyPlus engine. The optimization process is carried out parametrically controlling the shadings’ geometries. Genetic Algorithms (GA embedded in the evolutionary solver Galapagos are adopted in order to achieve close to optimum results by controlling iteration parameters. The optimized result, in comparison with conventional design techniques, reveals significant enhancement of comfort levels and energy efficiency. Benefits and drawbacks of the proposed strategy are then discussed.

  17. Savings in Cooling Energy with a Thermal Management System for LED Lighting in Office Buildings

    Directory of Open Access Journals (Sweden)

    Byung-Lip Ahn

    2015-06-01

    Full Text Available Light-emitting diode (LED lighting should be considered for lighting efficiency enhancement, however, waste heat from light-emitting diode (LED lighting increases the internal cooling load during the summer season. In order to solve this problem we propose a thermal management system for light-emitting diode (LED lighting with a heat exchanger module integrated with the building’s heating, ventilation, and air conditioning (HVAC system to move the lighting’s waste heat outdoors. An experiment was carried out to investigate the thermal effects in a test chamber and the heat exchange rate between the heat sink and the duct air. The heat generated by the light-emitting diode (LED lighting was calculated as 78.1% of light-emitting diode (LED input power and the heat exchange rate of the lighting heat exchange module was estimated to be between 86.5% and 98.1% according to the light-emitting diode (LED input power and the flow rate of air passing the heat sink. As a result, the average light-emitting diode (LED lighting heat contribution rate for internal heat gain was determined as 0.05; this value was used to calculate the heating and cooling energy demand of the office building through an energy simulation program. In the simulation results, the cooling energy demand was reduced by 19.2% compared with the case of conventionally installed light-emitting diode (LED lighting.

  18. Field measurements of perceived air quality and concentration of volatile organic compounds in four offices of the university building

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Kabrhel, M.

    2015-01-01

    Field measurements of perceived air quality were conducted in four refurbished offices at the Czech Technical University in Prague. The offices were refurbished as part of the research project Clear-up to serve as a field test facility. The present paper describes measurements conducted...... to investigate the perceived air quality, sensory pollution load and concentration of Volatile Organic Compounds (VOCs) in the offices. As the refurbishment comprised also installation of demand controlled ventilation (DCV), its influence on the perceived air quality was also tested. Measurements comprised...... the assessments of perceived air quality and objective measurements of operative temperature, relative humidity, CO2 and VOCs concentrations. Results showed that the mean sensory pollution load in unoccupied offices was 0.09 ± 0.01 olf/m2 (mean ± SEM). This falls into the category of a low-polluting building...

  19. Energy renovation of office building. Case: Faculty of Pharmaceutical Sciences, building 30; Energirenovering af kontorbygning. Eksempel: Det Farmaceutiske Fakultet, bygning 30

    Energy Technology Data Exchange (ETDEWEB)

    Wittchen, K.B.; Grud Christensen, M.; Weitzmann, P. (COWI A/S, Kgs. Lyngby (Denmark))

    2010-09-15

    The report is part of a larger project the aim of which was to develop a method for and examples of design of energy-extensive renovations (low-energy class 1) in order to stimulate energy savings and increased use of renewable energy in existing buildings. The report covers the renovation of a concrete office building in Copenhagen as an example. Here it has been proved that the studied measures, that have focused on the building envelope and ventilation and supply of renewable energy, split into two categories. Measures which focus on ventilation and utilization of solar energy in the form of both solar heat and solar cells lead to economic benefits. The insulation of the building envelope, however, is not economically attractive. Other measures like replacement of lighting systems have not been studied. (ln)

  20. Optimising for sun and light - the environmental performance of bio-climatic high-rise offices by Malaysian architect Kenneth Yeang

    Energy Technology Data Exchange (ETDEWEB)

    Ip, K.; Puteri Shireen Jahnkassim [University of Brighton (United Kingdom). School of the Environment

    2000-07-01

    Bioclimatic highrises represent an architectural response to the problem of regionalism in highrises and are based mainly on climate as a form determinant. They integrate sky courts, the use of vertical landscaping and vegetation, sun shading and use of natural ventilation in transitional areas such as the lift and ground floor lobbies. Sensitivity studies on bioclimatic highrises in tropical climate have shown that the use of daylight to save electric light and the optimum design of the building envelope can achieve significant energy savings by maintaining the balance between thermal and lighting requirements. In this study the overall envelope of two of Ken Yeang's highrise design, Menara Mesiniaga and Menara UMNO, are optimised with regards to the balance between the opposing impacts - daylight and solar gain. Apart from the external design features, the applications of photovoltaic systems to enhance the energy efficiency of these buildings are also investigated. The optimisation is carried out through the use of the FACET computer program that incorporates the use of dynamic thermal simulation program APACHE and lighting simulation RADIANCE. The paper concludes with the energy saving potential of bioclimatic design and limitations of the current study. (author)

  1. Building Strategic Leader Competencies into Army Officer Development and Career Progression

    Science.gov (United States)

    2011-03-23

    See also Casey Wardynski, David S. Lyle, and Michael J. Colarusso . Towards a U.S. Army Officer Corps Strategy for Success: Developing Talent...Wardynski, David S. Lyle, and Michael J. Colarusso . Towards a U.S. Army Officer Corps Strategy for Success: Developing Talent. Officer Corps Strategy Series

  2. Technical basis for radiological release of Grand Junction Office Building 2. Volume 2, dose assessment supporting data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    The second volume of the Grand Junction Office Action Program Technical Basis for Radiological Release of Grand Junction Office Building 2 report includes the data quality objectives (DQO), sampling plan, collected data, and analysis used to model future radiation doses to members of the public occupying Building 2 on the U.S. Department of Energy (DOE) Grand Junction Office (GJO) site. This volume was assembled by extracting relevant components of the Grand Junction Projects Office Remedial Action Project Building 2 Public Dose Evaluation (DOE 1996) and inserting recent additional data that was gathered and dose pathway modeling that was performed. The intent of this document is to provide all derived guidance decisions, assumptions, measured data, testing results, and pathway modeling software input and output data that supports the discussion and determinations presented in Volume 1 of this report. For constructive employment of this document, the reader is encouraged to closely follow Volume 1 for proper association with the segment of information being examined.

  3. Energy conservation in existing office buildings. Appendices to report, Phase I, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1977-06-01

    A blank form of Questionnaire No. 1 is first presented, followed by data compiled from that questionnaire. Then data are presented on the analyses of the 436 buildings, statistical validation for selection of the 44 building sample, and some examples of the matching buildings for the 44 building sample. Questionnaire No. 2 is then given, followed by additional data collected from the study concerning energy consumption and building characteristics. To complete the appendices, a simulation of a typical building and a hypothetical building is included. (MCW)

  4. 办公楼绿色建筑结构设计%Green Structural Design of Office Building

    Institute of Scientific and Technical Information of China (English)

    孔德欣

    2015-01-01

    我国正处于绿色建筑加速发展时期,节能设计与建筑能耗的问题越来越受到广泛的重视。通过某办公楼绿色建筑结构设计实例,对绿色建筑结构的体系选型、优化设计等方面进行阐述,为类似工程提供参考。%China is in a period of accelerated development of green building, and energy-saving design and building energy consumption problem is getting wide attention. Through the example of green structure design of a office building, the selection and optimized design of the green building structure are elaborated to provide reference for similar projects.

  5. Study on risk management for the implementation of energy efficient and renewable technologies in green office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mosly, I., E-mail: ibrahim.mosly@hotmail.com; Zhang, G., E-mail: kevin.Zhang@rmit.edu.au [RMIT University, Melbourne, Victoria (Australia). School of Civil, Environmental and Chemical Engineering

    2010-07-01

    Sustainability is becoming an important subject these days in many countries around the world. This is mainly due to increasing governmental and public awareness about reducing the impacts of climate change on our environment. Green buildings are able to reduce greenhouse gas emissions and consumption of natural resources. Reducing either water or energy consumption is achieved in green buildings with the aid of certain types of advanced technologies. This is done in order to help these buildings become more environmentally friendly. Unfortunately, these technologies are relatively new and may present a number of risks during various phases of their lifecycles, affecting different project stakeholders. This paper will focus on the risks of energy efficient and renewable technologies (EERTs), which are mainly implemented in green office buildings. These risks are divided into four categories: heating, ventilating and air conditioning (HVAC), lighting, solar, and wind. It will present a comprehensive review of a number of risks pertaining to the application of EERTs. Furthermore, it will emphasize the need to create a risk management framework for EERTs implemented in green office buildings due to the current lack of research carried out to investigate and treat these potential risks.

  6. Controlling Capital Costs in High Performance Office Buildings: A Review of Best Practices for Overcoming Cost Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Torcellini, P.

    2012-05-01

    This paper presents a set of 15 best practices for owners, designers, and construction teams of office buildings to reach high performance goals for energy efficiency, while maintaining a competitive budget. They are based on the recent experiences of the owner and design/build team for the Research Support Facility (RSF) on National Renewable Energy Facility's campus in Golden, CO, which show that achieving this outcome requires each key integrated team member to understand their opportunities to control capital costs.

  7. Contaminants in Buildings and Occupied Spaces as Risk Factors forOccupant Symptoms in U.S. Office Buildings: Findings from the U.S. EPABASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Mirer, A.; Lei-Gomez, Q.

    2007-08-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Most reported research into environmental risk factors for these symptoms has focused on ventilation system-related factors, dampness, and particle removal through filtration and cleaning, with relatively few studies of other potential sources of indoor contaminants. We analyzed data collected by the U.S. Environmental Protection Agency (EPA) from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate-adjusted logistic regression models with generalized estimating equations. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and a diverse set of potential indoor and outdoor sources for indoor pollutants. Although most of the investigated risk factors showed no apparent association with building-related symptoms, some interesting associations resulted. Increased prevalence of symptoms was associated with carpets older than one year (lower respiratory symptoms), non-carpeted floors (upper and lower respiratory symptoms), older furniture (eye and skin symptoms), infrequent vacuuming (upper respiratory, eye, and skin symptoms and headache), and masonry exterior walls (cough, eye symptoms, and fatigue/concentration difficulty). For the many potential risk factors assessed, almost none had been investigated previously, and many associations found here may have been by chance. Additional confirmatory research focused on risk factors initially identified here is needed, using more objective measures of health outcomes and risk factors or exposures.

  8. Low-cost and no-cost practice to achieve energy efficiency of government office buildings: A case study in federal territory of Malaysia

    Science.gov (United States)

    Tahir, Mohamad Zamhari; Nawi, Mohd Nasrun Mohd; Ibrahim, Amlus

    2016-08-01

    This paper presents the findings of a case study to achieve energy-efficient performance of conventional office buildings in Malaysia. Two multi-storey office buildings in Federal Territory of Malaysia have been selected. The aim is to study building energy saving potential then to highlight the appropriate measures that can be implemented. Data was collected using benchmarking method by comparing the measured consumption to other similar office buildings and a series of preliminary audit which involves interviews, a brief review of utility and operating data as well as a walkthrough in the buildings. Additionally, in order to get a better understanding of major energy consumption in the selected buildings, general audit have been conducted to collect more detailed information about building operation. In the end, this study emphasized low-cost and no-cost practice to achieve energy efficiency with significant results in some cases.

  9. Evaluating economic and environmental aspects of using solar panels on multi-angled facades of office buildings

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Lauring, Gert Michael; Christensen, Jørgen Erik

    2017-01-01

    This paper is concerned with using solar panels as high-tech cladding materials on multi-angled facades for office buildings. The energy produced by the solar panels will be consumed inside the office rooms by cooling compressors, ventilation, lighting and office equipment. Each multi-angled facade...... unit is directed into two different orientations on a vertical axis (right and left), but not tilted up and down. The different facade orientations will optimize the use of solar radiation to produce the needed energy from the solar panels when placing them on the parapets of these facades......, PVBAT to calculate the cost of the electricity produced by the solar panels and evaluate the total amount of energy produced from these panels along with the ratio to the energy bought directly from the electricity grid. There is also an environmental evaluation for the system by calculating the CO2...

  10. Anthrax letters in an open office environment: effects of selected CDC response guidelines on personal exposure and building contamination.

    Science.gov (United States)

    Kournikakis, Bill; Martinez, Kenneth F; McCleery, Robert E; Shadomy, Sean V; Ramos, Gabriel

    2011-02-01

    In 2001, letters filled with a powder containing anthrax (Bacillus anthracis) spores were delivered by mail to a number of governmental and media locations within the United States. In response, the U.S. Centers for Disease Control and Prevention (CDC) provided guidelines for office personnel who might encounter a letter containing suspicious powder. These guidelines were developed during the crisis and in the absence of experimental data from laboratory or field investigations. An obvious need thus exists for quantitative and scientific verification for validation of these guidelines. This study attempts to address this need, adapting earlier work that used a multiple small office test site to create a model system in an open office test site in a vacated office building in which Bacillus atrophaeus spores (as a simulant for B. anthracis spores) were released by opening a letter. Using SF(6) as a tracer gas, smoke tubes (containing stannic chloride) to visualize airflow, culturable aerosol sampling, and aerosol spectrometry we were able to characterize airflow and unmitigated spore aerosol dissemination within the office test site. Subsequently, two scripted test scenarios were used to reproduce selected portions of the existing CDC response guidelines and a modified version where the contaminated letter opener warned co-workers to evacuate then waited 5 min before doing so himself. By not leaving together with other co-workers, the risk of the letter opener cross-contaminating others was eliminated. The total potential spore aerosol exposure of the letter opener was not affected by remaining still and waiting 5 min to allow co-workers to escape first before leaving the office. Closing office doors and quickly deactivating the heating, ventilation, and air conditioning system significantly reduced spore aerosol concentrations outside the main open office in which they had been released.

  11. Evaluation of Various Retrofitting Concepts of Building Envelope for Offices Equipped with Large Radiant Ceiling Panels by Dynamic Simulations

    Directory of Open Access Journals (Sweden)

    Sabina Jordan

    2015-09-01

    Full Text Available In order to achieve significant savings in energy and an improved level of thermal comfort in retrofitted existing buildings, specific retrofitting concepts that combine new technologies and design need to be developed and implemented. Large radiant surfaces systems are now among the most promising future technologies to be used both in retrofitted and in new low-energy buildings. These kinds of systems have been the topic of several studies dealing with thermal comfort and energy utilization, but some specific issues concerning their possible use in various concepts for retrofitting are still poorly understood. In the present paper, some results of dynamic simulations, with the transient system simulation tool (TRNSYS model, of the retrofitted offices equipped with radiant ceiling panels are presented and thoroughly analysed. Based on a precise comparison of the results of these simulations with actual measurements in the offices, certain input data for the model were added, so that the model was consequently validated. The model was then applied to the evaluation of various concepts of building envelopes for office retrofitting. By means of dynamic simulations of indoor environment it was possible to determine the benefits and limitations of individual retrofitting concepts. Some specific parameters, which are relevant to these concepts, were also identified.

  12. Sustainable blob. Ambient heat for WWF office building in Holland; Nachhaltiger Blob. Umweltwaerme fuer Buerogebaeude des World Wildlife Fund in Holland

    Energy Technology Data Exchange (ETDEWEB)

    Alle, N.

    2007-05-15

    The Dutch group of architects, Rau, converted an existing laboratory building of the 1950 ies at Zeist, Netherlands, into a CO2-free office and visitor building of the World Wildlife Fund (WWF). With natural materials, organic design and integrated rooms for wild animals, the building has become part of the reservation on which it is located. (orig.)

  13. Total Energy Management: A Practical Handbook on Energy Conservation and Management. For Use of Owners and Managers of Office Buildings and Small Retail Stores. 2nd Edition.

    Science.gov (United States)

    National Electrical Contractors Association, Washington, DC.

    Described in this guide for owners and managers of office buildings and small retail stores, is a program entitled Total Energy Management (TEM). The TEM program approach rests on the premise that buildings should be examined in terms of total energy consumption, rather than prescribing energy budgets for a building's separate systems. The…

  14. Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads.

    Science.gov (United States)

    Wargocki, P; Wyon, D P; Baik, Y K; Clausen, G; Fanger, P O

    1999-09-01

    Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in an existing office in which the air pollution level could be modified by introducing or removing a pollution source. This reversible intervention allowed the space to be classified as either non-low-polluting or low-polluting, as specified in the new European design criteria for the indoor environment CEN CR 1752 (1998). The pollution source was a 20-year-old used carpet which was introduced on a rack behind a screen so that it was invisible to the occupants. Five groups of six female subjects each were exposed to the conditions in the office twice, once with the pollution source present and once with the pollution source absent, each exposure being 265 min in the afternoon, one group at a time. They assessed the perceived air quality and SBS symptoms while performing simulated office work. The subject-rated acceptability of the perceived air quality in the office corresponded to 22% dissatisfied when the pollution source was present, and to 15% dissatisfied when the pollution source was absent. In the former condition there was a significantly increased prevalence of headaches (P = 0.04) and significantly lower levels of reported effort (p = 0.02) during the text typing and calculation tasks, both of which required a sustained level of concentration. In the text typing task, subjects worked significantly more slowly when the pollution source was present in the office (P = 0.003), typing 6.5% less text than when the pollution source was absent from the office Reducing the pollution load on indoor air proved to be an effective means of improving the comfort, health and productivity of building occupants.

  15. Seasonal frost effects on the dynamic behavior of a twenty-story office building

    Science.gov (United States)

    Yang, Z.; Dutta, U.; Xiong, F.; Biswas, N.; Benz, H.

    2008-01-01

    Studies have shown that seasonal frost can significantly affect the seismic behavior of a bridge foundation system in cold regions. However, little information could be found regarding seasonal frost effects on the dynamic behavior of buildings. Based on the analysis of building vibration data recorded by a permanent strong-motion instrumentation system, the objective of this paper is to show that seasonal frost can impact the building dynamic behavior and the magnitude of impact may be different for different structures. Ambient noise and seismic data recorded on a twenty-story steel-frame building have been analyzed to examine the building dynamic characteristics in relationship to the seasonal frost and other variables including ground shaking intensity. Subsequently, Finite Element modeling of the foundation-soil system and the building superstructure was conducted to verify the seasonal frost effects. The Finite Element modeling was later extended to a reinforced-concrete (RC) type building assumed to exist at a similar site as the steel-frame building. Results show that the seasonal frost has great impact on the foundation stiffness in the horizontal direction and a clear influence on the building dynamic behavior. If other conditions remain the same, the effects of seasonal frost on structural dynamic behavior may be much more prominent for RC-type buildings than for steel-frame buildings. ?? 2007 Elsevier B.V. All rights reserved.

  16. Tightness of the thermal envelope of office and educational buildings; Klimaskaermens taethed i kontor- og undervisningsbygninger

    Energy Technology Data Exchange (ETDEWEB)

    Bergsoee, N.C. (SBi, Aalborg (Denmark)); Radisch, N.H.; Nickel, J.; Treldal, J. (Ramboell Danmark A/S, Koebenhavn (Denmark)); Bundesen, E.W.; Nielsen, Carsten (DanEjendomme, Hellerup (Denmark))

    2011-07-01

    In 2006 tightening of the energy regulations in the Danish Building Regulations were introduced including requirements regarding the tightness of the building envelope. The requirements are, with minor changes, continued in the current Building Regulations, BR10. During the past few years experience has been gained regarding both the actual execution of air tightness measurements and solutions that will lead to more air tight building envelopes. Experiences, however, are primarily related to single family houses. The report presents results of measurements in large buildings and discusses reasons for lack of knowledge and experience on the tightness of the building envelope in large buildings. Apparently, there is a need for dissemination of knowledge on the importance of a tight building envelope both in terms of energy consumption and indoor climate and in terms of the difficulties and costs associated with repairing leaks in a completed envelope. Air tightness must be brought into focus at an early stage in the planning process, and during the construction phase air tightness measurements should be performed, e.g. on facade sections or in parts of the building. The project team has attended a number of measurements in large buildings and further gained access to results of a large number of measurements. In summary, the results show that it is possible to achieve the required tightness, and in most buildings the results are better than the requirement of a maximum of 1.5 l/s per m{sub 2}. (Author)

  17. US Department of Energy Grand Junction Projects Office Remedial Action Project. Final report of the decontamination and decommissioning of Building 52 at the Grand Junction Projects Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Krabacher, J.E.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also was the remedial action contractor. Building 52 was found to be radiologically contaminated and was demolished in 1994. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  18. Assessing Quality of Working Life Among Malaysian Workers.

    Science.gov (United States)

    Sulaiman, Nur Suffia; Choo, Wan Yuen; Mat Yassim, Abdul Rahim; Van Laar, Darren; Chinna, Karuthan; Majid, Hazreen Abdul

    2015-11-01

    The Work-Related Quality of Life Scale-2 (WRQLS-2) has been used to measure quality of working life (QOWL) in the United Kingdom. In this study, the scale was translated and normalized into Malay. The scale was translated using the back-translation method, pretesting, and pilot testing. It was conducted among health care and office workers. It was tested in 3 stages; confirmatory factor analysis at stages 1 and 3 and exploratory factor analysis at stage 2. The Malaysian WRQLS-2 had 5 factors: "General Well-Being," "Job and Career Satisfaction," "Employee Engagement," "Home-Work Interface," and "Stress at Work." The scale showed good convergent and construct validity and also reliability. Perception of good QOWL may differ because of cultural influences and varying work environments. The validated Malaysian WRQLS-2 can be used to determine the QOWL of Malaysian office and health care workers.

  19. Final report of the decontamination and decommissioning of Building 44 at the Grand Junction Projects Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. Building 44 was radiologically contaminated and the building was demolished in 1994. The soil area within the footprint of the building was not contaminated; it complies with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  20. Final report of the decontamination and decommissioning of Building 34 at the Grand Junction Projects Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, was also the remedial action contractor. Building 34 was radiologically contaminated and the building was demolished in 1996. The soil area within the footprint of the building was analyzed and found to be not contaminated. The area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual closeout report for each contaminated GJPO building.

  1. 绿色办公建筑的探索%The Exploration of the Green Office Building

    Institute of Scientific and Technical Information of China (English)

    舒丹

    2013-01-01

    In the green office building design, in order to bea-utify the building green landscape, do layers of greening, imp-rove the environment quality of the building and the work eff-iciency, the design principles of“Inner Courtyard Type”of ar-chitectural composition and the“Garden Type”of environme-ntal landscape must be fol owed. This article mainly describes the green design of an office building.%在绿色办公建筑设计中,为美化建筑绿化景观,做到层层有绿化、提升建筑环境质量、提高工作效率,在设计中应遵循建筑布局“内庭式”、环境景观“花园式”的设计原则。本文主要阐述了某办公建筑的绿色设计。

  2. Air conditioning and energy conservation. Improved space HVAC systems. Case studies: Office buildings, hotels, shopping centers, skyscrapers, industrial plants

    Energy Technology Data Exchange (ETDEWEB)

    Heiner, H.

    1988-08-01

    Rising energy prices and an increasing demand for comfortable rooms account for the importance attached to the windows and glass used for office buildings, hotels and industrial plants. Both windows and glass have a considerable influence on the thermal behavior and air conditioning of buildings. Among the latest developments are precious metal-coated insulating panes. Selected gases allow to reduce the total thickness of insulating glass and improve noise insulation. The case studies presented refer to the energy-saving air conditioning and space heating, heat recovery and cooling of rooms as well as to the respective control systems. Investigations into the specific energy consumption of building shells reveal the considerable space/tap water heating energy conservation potentials remaining to be utilized.

  3. Demonstration of microorganisms and dust in schools and offices. An observational study of non-industrial buildings.

    Science.gov (United States)

    Gravesen, S; Larsen, L; Gyntelberg, F; Skov, P

    1986-09-01

    "The sick-building syndrome" (WHO) is reported with increasing intensity in non-industrial places of work, such as schools, kindergartens, and offices, all of which have a heavy load of traffic (people). The construction of these buildings (e.g. flat roofs) often leads to water damage with subsequent microbial growth. Further, reduced cleaning budgets in connection with the wide use of needle-felt carpets, as well as ventilation systems not regularly maintained, will lead to pollution by dust and microorganisms. A systematic registration of dust and microbial parameters has been carried out since 1980 in buildings with indoor climate complaints, in order to elucidate the possible influence of these factors.

  4. Energy balances of four office buildings in different locations in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Soutullo, Silvia; Enriquez, Ricardo; San Juan, Cristina; Ferrer, Jose Antonio; Heras, M Rosario [Energy Efficiency in Buildings R and D Unit., CIEMAT, Madrid (Spain)], email: silvia.soutullo@ciemat.es

    2010-07-01

    Southern Europe climates are characterized by important heating and cooling needs, thus to minimize the greenhouse gas emissions, efficient buildings must be designed. Two types of techniques can be used: passive techniques which consist in optimizing the building design to reduce its energy demand and then the implementation of active renewable energy systems to supply all the demand. The aim of this study is to present the design and analysis process of buildings in Spain. Simulations using TRNSYS 16 were performed on 4 buildings situated in Madrid, Almeria, Asturias and Soria to represent all climates of Spain. Results showed that efficient buildings can be designed in Southern Europe and that the simulation tool is a good means to optimize the combination of passive and active solar systems; it was found that 80% of the present energy consumption can be saved. The design and analysis process presented herein was proved to help in optimizing the energy consumption of buildings in Southern Europe.

  5. Simulation-based support for integrated design of new low-energy office buildings

    DEFF Research Database (Denmark)

    Petersen, Steffen

    design disciplines (structural, fire, architecture etc.) to the integrated building design process. The research therefore revolves around the hypothesis that parametric analyses on the energy performance, indoor environment and total economy of rooms with respect to geometry and characteristics...... of building elements and services can be used to generate a useful input to the early stage of an integrated building design process. To pursue a corroboration of this hypothesis, a method for making informed decisions when establishing the input to the overall building design process is proposed. The method...... relies on the use of building simulation to illustrate how design parameters will affect the energy performance and the quality of the indoor environment prior to any actual design decision. The method is made operational in a simple building simulation tool capable of performing integrated performance...

  6. The physical environment and occupant thermal perceptions in office buildings. An evaluation of sampled data from five European countries

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J.L. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2002-02-01

    The results from a large field study of thermal comfort in European office buildings are reported. Measurements of physical environmental conditions and occupant perceptions were collected over sixteen months from twenty-six different office buildings located in France, Greece, Portugal, Sweden and the UK. This thesis focuses on the physical environmental measurements and occupant thermal perceptions; however, additional variables with connections to environmental satisfaction are also examined. An overview of human comfort theory is presented to help place this thesis in appropriate context. The overview presents thermal comfort issues within a broad framework of human response to the environment including physical, physiological. behavioural, psychological and other variables. A more narrowly focused overview of current thermal comfort research is also included. The work attempts to show relationships and produce useful information from the data set using graphical methods, especially lowess, a locally weighted regression based scatter plot smoothing technique. The objective of using this approach is to literally show the relationships visually. This approach allows the data set itself to illustrate the actual thermal conditions in European office buildings and the occupant perceptions of those conditions along with illustrating relationships. The data is examined in some detail with key relationships identified and explored. Significant differences between countries, both for the physical conditions and the perceptions of those conditions are identified. In addition, the variation over the course of the year for each country is explored. The relationship of daily average outdoor temperatures to indoor temperatures and indoor temperature perceptions is found to be critically important. The relationships, which appear to drive perceptions of thermal comfort, occur in complex ways, making simple, all encompassing explanations impossible. The nature and size of the

  7. Do Certified Buildings Enhance Indoor Environmental Quality and Performance of Office Work?

    DEFF Research Database (Denmark)

    Da Silva, Nuno Alexandre Faria; Wargocki, Pawel

    2014-01-01

    With the growth of sustainability consciousness, the awareness of stakeholders for high performance buildings has also increased. The concept of green buildings has appeared. Several voluntary environmental rating schemes for buildings were created. Their focus has been energy conservation...... and environmental impacts. The schemes use different credit system for various variables and different approaches to rate indoor environmental quality (IEQ) (Figure 1). It is interesting to examine, whether human related factors are properly addressed in the schemes, especially considering the potential effects...

  8. Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2015-05-01

    Full Text Available This study investigated whether sick building syndrome (SBS complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2, temperature, humidity and total volatile organic compounds (TVOCs in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2 was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%, difficulty in concentrating (14.6%, eye dryness (18.7% were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs and 95% confidence interval (CI per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22, tiredness (1.16, 95% CI = (1.04–1.29 and dizziness (1.22, 95% CI = (1.08–1.37. The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07, dry throat (1.06, 95% CI = (1.03–1.09 and irritability (1.02, 95% CI = (1.01–1.04. In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.

  9. Evaluating economic and environmental aspects of using solar panels on multi-angled facades of office buildings

    Science.gov (United States)

    Hannoudi, Loay Akram; Lauring, Michael; Christensen, Jørgen Erik

    2017-09-01

    This paper is concerned with using solar panels as high-tech cladding materials on multi-angled facades for office buildings. The energy produced by the solar panels will be consumed inside the office rooms by cooling compressors, ventilation, lighting and office equipment. Each multi-angled facade unit is directed into two different orientations on a vertical axis (right and left), but not tilted up and down. The different facade orientations will optimize the use of solar radiation to produce the needed energy from the solar panels when placing them on the parapets of these facades. In this regard, four scenarios with different facade configurations and orientations are evaluated and discussed. The method for the simulations and calculations depends on two main programs: first, IDA ICE program to calculate the energy consumption and evaluate the indoor climate of the building; and second, PVBAT to calculate the cost of the electricity produced by the solar panels and evaluate the total amount of energy produced from these panels along with the ratio to the energy bought directly from the electricity grid. There is also an environmental evaluation for the system by calculating the CO2 emissions in the different scenarios.

  10. Final Environmental Assessment for the construction and operation of an office building at the Stanford Linear Accelerator Center. Part 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The Department of Energy (DOE) has prepared an Environmental Assessment (EA), DOE/EA-1107, analyzing the environmental effects relating to the construction and operation of an office building at the Stanford Linear Accelerator Center (SLAC). SLAC is a national facility operated by Stanford University, California, under contract with DOE. The center is dedicated to research in elementary particle physics and in those fields that make use of its synchrotron facilities. The objective for the construction and operation of an office building is to provide adequate office space for existing SLAC Waste Management (WM) personnel, so as to centralize WM personnel and to make WM operations more efficient and effective. Based on the analyses in the EA, the DOE has determined that the proposed action does not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA). Therefore, the preparation of an Environmental Impact Statement is not required. This report contains the Environmental Assessment, as well as the Finding of No Significant Impact (FONSI).

  11. Indoor Environmental Risk Factors for Occupant Symptoms in 100U.S. Office Buildings: Summary of Three Analyses from the EPA BASEStudy

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Cozen, M.; Brightman, H.S.; Apte,M.; Erdmann, C.A.; Brunner, G.; Girman, J.R.

    2006-02-01

    This paper summarizes three analyses of data on building-related environmental factors and occupant symptoms collected from 100 representative large U.S. office buildings. Using multivariate logistic regression models, we found increased occupant symptoms associated with a number of building-related factors, including lower ventilation rates even at the current guideline levels, lack of scheduled cleaning for air-conditioning drain pans and cooling coils, poor condition of cooling coils, poorly maintained humidification systems, and lower outdoor air intake height. Some expected relationships were not found, and several findings were opposite of expected. Although requiring replication, these findings suggest preventive actions to reduce occupant symptoms in office buildings.

  12. Indoor Environmental Risk Factors for Occupant Symptoms in 100U.S. Office Buildings: Summary of Three Analyses from the EPA BASEStudy

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Cozen, M.; Brightman, H.S.; Apte,M.; Erdmann, C.A.; Brunner, G.; Girman, J.R.

    2006-02-01

    This paper summarizes three analyses of data on building-related environmental factors and occupant symptoms collected from 100 representative large U.S. office buildings. Using multivariate logistic regression models, we found increased occupant symptoms associated with a number of building-related factors, including lower ventilation rates even at the current guideline levels, lack of scheduled cleaning for air-conditioning drain pans and cooling coils, poor condition of cooling coils, poorly maintained humidification systems, and lower outdoor air intake height. Some expected relationships were not found, and several findings were opposite of expected. Although requiring replication, these findings suggest preventive actions to reduce occupant symptoms in office buildings.

  13. Final report of the radiological release survey of Building 30B at the Grand Junction Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Krauland, P.A.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 30B and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  14. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    This document is the Final Report of the Solar Energy System Installed at the First Solar Heated Office Building, One Solar Place, Dallas, Texas. The Solar System was designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 Solargenics, series 76, flat plate collectors with a total area of 1596 square feet. The solar loop circulates an ethylene glycol-water solution through the collectors into a hot water system heat exchanger. The hot water storage subsystem consists of a heat exchanger, two 2300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water fixtures. The building cold water system provides make-up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described. The system became operational July 11, 1979.

  15. Analysis of the Public Space Design in the Office Building%浅析办公建筑中的公共空间设计

    Institute of Scientific and Technical Information of China (English)

    卢炫

    2014-01-01

    More and more office buildings are increasing. Compared with ordinary construction projects, the office buildings pay more at ention to the design of public space aiming to provide people with a comfortable, healthy, efficient environment. Therefore, people need continuously optimize and improve the public space design of office buildings and promote the fast development of office buildings.%各个地区的办公建筑数量越来越多。和普通建筑工程相比,办公建筑更加注重公共空间的设计,旨在为人们提供一个舒适、健康、快捷的环境。因此要不断优化和完善办公建筑中的公共空间设计,推动办公建筑快速发展。

  16. Malaysian Cinema, Asian Film

    NARCIS (Netherlands)

    Heide, van der William

    2002-01-01

    This title series departs from traditional studies of national cinema by accentuating the intercultural and intertextual links between Malaysian films and Asian (as well as European and American) film practices. Using cross-cultural analysis, the author characterizes Malaysia as a pluralist society

  17. HVAC in sustainable office buildings a bridge between owners and engineers

    CERN Document Server

    Hovorka, Frank; Kurnitski, Jarek; Litiu, Andrei

    2012-01-01

    This guidebook aims to build a bridge between the real estate community and the engineering community. It explains the challenges of property valuation based on real data and how the sustainability and HVAC-technology can have an impact on value. It also gathers the latest HVAC- and other technologies used in sustainable buildings and gives some real case study examples. But maybe the most important part in terms of improved communication between the owners and engineers is the list of questions to be asked during the life time of a building. It is impossible to give all the right answers in this guidebook, but we will raise some pertinent questions. As climates and cultures are different, as well as existing building types and energy production, the same solutions do not solve problems universally. This guidebook is aimed for the owners and architects as well as engineers. It doesn’t require deep technical knowhow of HVAC-systems or real estate valuation.

  18. Highlighting High Performance: Four Times Square. Office of Building Technology, State and Community Programs (BTS) Brochure

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-11-01

    4 Times Square is a 48-story environmentally responsible building in New York City and is the first project of its size to adopt standards for energy efficiency, indoor ecology, sustainable materials.

  19. Do Certified Buildings Enhance Indoor Environmental Quality and Performance of Office Work?

    DEFF Research Database (Denmark)

    Da Silva, Nuno Alexandre Faria; Wargocki, Pawel

    2014-01-01

    on productivity and that an average employee cost can be >10-100 times higher than the rental operation and maintenance costs (Morrell, 2005; Persramet al., 2007). There is however lack of consistent and systematic data benchmarking benefits of green building, in particular as regards IEQ and the effects...... on humans. Health, comfort and work performance outcomes are more difficult to quantify than the effects on energy. As a result, it may be expected that credits for IEQ in the schemes be traded with other credits. If so, although claimed to have an outstanding IEQ as compared with conventional buildings...... there is any systematic evidence that these buildings outperform conventional buildings as regards IEQ either through actual IEQ measurements, subjective assessments made by occupants and/or objectively and self-estimated work performance....

  20. 某核电厂生产办公楼的建筑设计%Production office building design of nuclear power plant

    Institute of Scientific and Technical Information of China (English)

    车新路; 赵书娴

    2016-01-01

    Combining with the general horizontal layout scheme of the production office building of the nuclear power plant,introduces its spatial composite features,describes matters needing attention in the production office building design of the nuclear power plant from aspects of the of-fice building design demands,the relationship between the nuclear power plant production office building and the nuclear power plant workshop, office building space features,with a view to realize the office building serving targets of “convenient management and safe production”.%结合某核电厂生产办公楼的总平面布局方案,介绍了其平面空间组合特点,并从办公楼的设计要求、办公楼与厂区关系、办公空间特质等方面,阐述了核电厂生产办公楼设计的注意要点,旨在实现办公楼“便于管理、安全生产”的服务目标。

  1. From Bunker to Building: Results from the 2010 Chief Human Resource Officer Survey

    Science.gov (United States)

    Wright, Patrick M.; Stewart, Mark

    2011-01-01

    In 2009, the researchers, with funding from the Center for Advanced Human Resource Studies (CAHRS), began conducting the annual Chief Human Resource Officers (CHRO) Survey. The 2009 survey was sent to CHROs at the U.S. Fortune 150 companies, as well as to ten other CHROs at CAHRS partner companies. That survey focused on understanding how CHROs…

  2. Final report of the decontamination and decommissioning of Building 18 at the Grand Junction Projects Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. The soil beneath Building 18 was found to be radiologically contaminated; the building was not contaminated. The soil was remediated in accordance with identified standards. Building 18 and the underlying soil can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  3. Sustainability and satisfaction : findings from field studies of office buildings in the UK and India

    Energy Technology Data Exchange (ETDEWEB)

    Manchanda, S. [Cambridge Univ., Cambridge (United Kingdom). Martin Centre for Architectural and Urban Studies; Steemers, K. [Cambridge Univ., Cambridge (United Kingdom). Dept. of Architecture

    2009-07-01

    Ventilation and air-conditioning constitute the prime consumers of energy in buildings, largely because these services require high energy mechanical systems to meet satisfactory thermal and indoor air quality requirements for occupants. However, growing concerns regarding energy security and the environment raise certain questions in relation to the justification of these high levels of energy use by buildings. This paper explored the relationship between the use of energy by buildings, and their performance in terms of the satisfaction of the end-user and the key determinants and influencing factors. The authors questioned whether high levels of energy use in buildings are really necessary for delivering a better environment and satisfaction for the end-user. They also questioned to what extent occupant satisfaction depends on parameters affected by energy use. In general, the study concluded that energy use in buildings and user satisfaction are not necessarily related. The study suggested that high levels of satisfaction can be achieved with low energy design, and at a broad level. It pointed out critical environmental criteria and pertinent psychological mechanisms that can be used to maximize satisfaction while limiting energy use. Alternatives for sustainable design and improved occupant satisfaction were explored. 14 refs., 2 tabs., 4 figs.

  4. Infrared Thermographic Quality Control For Newly Constructed Office Buildings Prior To Closing

    Science.gov (United States)

    Allen, Sharon

    1987-05-01

    The use of infrared thermographic building diagnostics, prior to final closing, is an effective method of quality control. Thermal envelope studies using infrared technology, made prior to contractual release, are a cost effective means of insuring the buyer and builder that the thermal envelope performs to the specifications of the construction contract. Building owners and builders can both benefit. Builders are able to close jobs and avoid costly call backs after occupancy. Building owners gain knowledge as to how the building envelope can be expected to perform in coming seasons. A majority of problems can be avoided during construction when infrared thermographic building diagnostics are introduced at the beginning of a project. Problems may be dealt with during construction, not afterwards. Contractors are alerted to how their job affects the performance of other trades and materials in the structure. To gain the most from infrared thermography during the construction phase, the contractors and thermographer must have an understanding of each other's function. On-site visits during construction can provide contractors with a basic background of thermal imaging and familiarize the thermographer with various construction techniques and materials used.

  5. Improving Occupant Wellness in Commercial Office Buildings through Energy Conservation Retrofits

    Directory of Open Access Journals (Sweden)

    J. J. McArthur

    2015-10-01

    Full Text Available There is increasing literature demonstrating the link between building indoor environmental quality, and occupant health and productivity, driving the corporate real estate industry to investigate how to integrate wellness features in both new and existing building stock. Meanwhile, new voluntary standards to promote occupant health are becoming adopted alongside sustainability standards. As commercial building owners and tenants seek to improve occupant conditions and incorporate wellness, apparently conflicting priorities must be balanced, particularly improving indoor environmental conditions has the potential to increase energy. This paper presents a framework to consider retrofits holistically and considering the benefit of improved conditions both qualitatively and quantitatively. Where poor conditions exist, published literature demonstrates a lost productivity cost that exceeds typical building energy costs, and this is quantified in the financial analysis presented. Energy retrofits provide a unique opportunity to integrate wellness-enabling features because the energy savings can offset marginal energy or operating cost increases for particular wellness interventions. This paper presents a flexible, customizable framework to develop potential retrofit bundles and evaluate them considering economic, sustainability, wellness, risk and occupant experience factors to identify the optimal zone of retrofit. An illustrative case study using real building data demonstrates how the framework might be applied to a real project and customized to achieve unique stakeholder priorities.

  6. Perceived Comfort of Indoor Environment and Users' Performance in Office Building with Smart Elements - case Study

    Science.gov (United States)

    Pilipová, Ivana; Vilčeková, Silvia

    2013-11-01

    A greater degree of awareness of comfort and productivity of building users according to post-occupancy evaluation and feedback of users in intelligent buildings is necessary. This report presents a summary of the results from a physical measurements, a post-occupancy evaluation study on perceived comfort of indoor environment and self-evaluation of occupant's performance in the new multifunctional 5 floor-building in city of Kosice, Slovakia. There were investigated degree of perceived comfort and user's performance with regard to objective measurement, respondents' response and building character. This case study has highlighted that influence of monitored factors of building with smart elements is positively received and wasn't determined their negative impact on perceived comfort of indoor environment and occupants' performance. Results show that respondents are mostly satisfied with their indoor environment conditions of workplace. Interviews with respondents detected they have not been perceived (negative) factors in workplace because they have been too concentric on the work and they have not felt discomfort.

  7. Reducing Plug and Process Loads for a Large Scale, Low Energy Office Building: NREL's Research Support Facility; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lobato, C.; Pless, S.; Sheppy, M.; Torcellini, P.

    2011-02-01

    This paper documents the design and operational plug and process load energy efficiency measures needed to allow a large scale office building to reach ultra high efficiency building goals. The appendices of this document contain a wealth of documentation pertaining to plug and process load design in the RSF, including a list of equipment was selected for use.

  8. Property types diversification strategy of Malaysian real estate investment trust (M-REITs

    Directory of Open Access Journals (Sweden)

    Ping Tiong Chai

    2016-01-01

    Full Text Available The aim of this paper is to review the property types diversification strategy of Malaysian REITs. Previous study has found that Malaysian REITs received poor response form investors both local and international. Furthermore, the underperformance of Malaysian REITs was linked to the characteristics of REITs’ property types and REITs’ portfolio influenced its financial performance. The lack of local study on both of these determinants of influence on performance of Malaysian REITs is a research gap, which needs to be explored that can provide more insight of it. This study showed that the property types such as office space, commercial lot, industrial, hotel and specialized property type are the important determinants, which can influence the performance of REITs. The study comprised of REITs data from 2010 until 2014, and through Multiple Regression Analysis (MRA reveals there is little influence of property types diversification strategy toward Malaysian REITs’ performance. Nevertheless, by employ correlation analysis between each of the five property types with expected return and dividend yield, this study shows Malaysian REITs’ performance of dividend yield(DY has a positive correlation value with commercial lot property type and Malaysian REITs’ performance of expected return(ER have a highest positive correlation value with industrial property types. Also, this study suggests that property type diversification play a significant role in Malaysia REITs. Other determinants such as location of property, market capitalization and REITs’ quality of advisory style that might influence the diversification strategy and financial performance of Malaysian REITs.

  9. Investigation on the impacts of different genders and ages on satisfaction with thermal environments in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, JoonHo; Aziz, Azizan; Loftness, Vivian [Center for Building Performance and Diagnostics, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213 (United States)

    2010-06-15

    This paper investigates the effects of occupant gender and age on thermal satisfaction in office environments. The data used for the analyses was collected from 40-sampled occupants and their workstations on 38 floors in 20 office buildings in the U.S. with support from the U.S. General Services Administration. The field measurements include data collection for air temperature, radiant temperature, temperature stratification, relative humidity and air velocity of the sampled workstations. Occupant satisfaction surveys were distributed to each occupant in the workstations measured, and the thermal attributes of building systems were recorded. The objective and subjective data sets support statistical correlation analysis between environmental qualities and user satisfactions. The statistical analysis of air temperatures, occupant thermal satisfaction, age and gender revealed that females are more dissatisfied with their thermal environments than males especially in the summer season with high significance, and occupants over 40 years old are more satisfied than under 40 in the cooling season with marginal significance. (author)

  10. Bi-level Optimization Method of Air-conditioning System Based on Office Building Energy Storage Characteristics

    Science.gov (United States)

    Wang, Qingze; Chen, Xingying; Ji, Li; Liao, Yingchen; Yu, Kun

    2017-05-01

    The air-conditioning system of office building is a large power consumption terminal equipment, whose unreasonable operation mode leads to low energy efficiency. Realizing the optimization of the air-conditioning system has become one of the important research contents of the electric power demand response. In this paper, in order to save electricity cost and improve energy efficiency, bi-level optimization method of air-conditioning system based on TOU price is put forward by using the energy storage characteristics of the office building itself. In the upper level, the operation mode of the air-conditioning system is optimized in order to minimize the uses’ electricity cost in the premise of ensuring user’ comfort according to the information of outdoor temperature and TOU price, and the cooling load of the air-conditioning is output to the lower level; In the lower level, the distribution mode of cooling load among the multi chillers is optimized in order to maximize the energy efficiency according to the characteristics of each chiller. Finally, the experimental results under different modes demonstrate that the strategy can improve the energy efficiency of chillers and save the electricity cost for users.

  11. Eco-sewerage System Design for Modern Office Buildings: based on Vacuum and Source-separation Technology

    Science.gov (United States)

    Xu, Kangning; Wang, Chengwen; Zheng, Min; Yuan, Xin

    2010-11-01

    This study aimed to construct an on-site eco-sewerage system for modern office buildings in urban area based on combined innovative technologies of vacuum and source-separation. Results showed that source-separated grey water had low concentrations of pollutants, which helped the reuse of grey water. However, the system had a low separation efficiency between the yellow water and the brown water, which was caused by the plug problem in the urine collection from the urine-diverting toilets. During the storage of yellow water for liquid fertilizer production, nearly all urea nitrogen transferred to ammonium nitrogen and about 2/3 phosphorus was lost because of the struvite precipitation. Total bacteria and coliforms increased first in the storage, but then decreased to low concentrations. The anaerobic/anoxic/aerobic MBR had high elimination rates of COD, ammonium nitrogen and total nitrogen of the brown water, which were 94.2%, 98.1% and 95.1%, respectively. However, the effluent still had high contents of colority, nitrate and phosphorus, which affected the application of the effluent for flushing water. Even though, the effluent might be used as dilution water for the yellow water fertilizer. Based on the results and the assumption of an ideal operation of the vacuum source-separation system, a future plan for on-site eco-sewerage system of modern office buildings was constructed. Its sustainability was validated by the analysis of the substances flow of water and nutrients.

  12. Consumer decision and behavior research agenda for the Office of Building and Community Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mohler, B.L.; Scheer, R.M.; Barnes, V.

    1985-12-01

    This report presents a research agenda of Consumer Decision and Behavior Projects related to improving, facilitating and planning Building and Community Systems, (BCS) research and development activities. Information for developing this agenda was gathered through focus group and depth interviews with BCS staff, directors and program managers.

  13. Simulations of the potential revenue from investment in improved indoor air quality in an office building

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Djukanovic, Rade

    2005-01-01

    of improved worker performance; benefits from reduced health costs and sickness absence were not included. The building was simulated in a cold, a moderate and a hot climate. It was ventilated by a constant air volume (CAV) system with heat recovery and by a variable air volume (VAV) system with an economizer...

  14. Performance analysis of air source heat pump system for office building

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong Won; KIm, Yong Chan [Korea University, Seoul (Korea, Republic of); Chang, Young Soo [School of Mechanical System Engineering, Kookmin University, Seoul (Korea, Republic of)

    2016-11-15

    In this study, the performance of an air source heat pump system installed in a commercial building is analyzed using the developed heat pump performance model and building load simulation data of several regions in Korea. The performance test of an air source heat pump system with a variable speed compressor is tested to develop model that considers changes in the performance characteristics of the heat pump system under various operating conditions. The heat pump system is installed in an environmental chamber, and the experimental equipment is set up according to the manufacturer' specifications as well as the AHRI 1230 test specifications. The performance test conditions of the heat pump system are selected using a central composite design method, in which 29 points for each cooling and heating mode are selected. The developed performance model based on experimental data predicts experimental values with an error of ±5 %. Building cooling and heating loads in three regions in Korea are analyzed using TRNSYS software, which includes standard building and weather data from Seoul, Daejeon and Busan in Korea. The effects of outdoor air temperature and part load ratio on the performance and regional monthly average power consumption of the heat pump system are analyzed.

  15. Sustainability and office building conversions: A comparison of Dutch and Australian practices

    NARCIS (Netherlands)

    Remøy, H.T.; Wilkinson, S.J.

    2011-01-01

    Local Authorities worldwide are encouraging adaptation to reduce building related energy consumption and greenhouse gas emissions. The City of Melbourne is promoting the retrofit of 1,200 CBD properties before 2020 with sustainability measures as part of their policy to become a carbon neutral city,

  16. Thermal Comfort and Energy Consumption Using Different Radiant Heating/Cooling Systems in a Modern Office Building

    Science.gov (United States)

    Nemethova, Ema; Stutterecker, Werner; Schoberer, Thomas

    2017-06-01

    The aim of the study is to evaluate the potential of enhancing thermal comfort and energy consumption created by three different radiant systems in the newly-built Energetikum office building. A representative office, Simulation room 1/1, was selected from 6 areas equipped with portable sensor groups for the indoor environment monitoring. The presented data obtained from 3 reference weeks; the heating, transition and cooling periods indicate overheating, particularly during the heating and transition period. The values of the indoor air temperature during the heating and transition period could not meet the normative criteria according to standard EN 15251:2007 (cat. II.) for 15-30% of the time intervals evaluated. Consequently, a simulation model of the selected office was created and points to the possibilities of improving the control system, which can lead to an elimination of the problem with overheating. Three different radiant systems - floor heating/ cooling, a thermally active ceiling, and a near-surface thermally active ceiling were implemented in the model. A comparison of their effects on thermal comfort and energy consumption is presented in the paper.

  17. Indicators of moisture and ventilation system contamination in U.S. office buildings as risk factors for respiratory and mucous membrane symptoms: analyses of the EPA BASE data.

    Science.gov (United States)

    Mendell, Mark J; Cozen, Myrna; Lei-Gomez, Quanhong; Brightman, Howard S; Erdmann, Christine A; Girman, John R; Womble, Susan E

    2006-05-01

    We assessed associations between indicators for moisture in office buildings and weekly, building-related lower respiratory and mucous membrane symptoms in office workers, using the U.S. EPA BASE data, collected in a representative sample of 100 U.S. office buildings. We estimated the strength of associations between the symptom outcomes and moisture indicators in multivariate logistic regression models as odds ratios (ORs) and 95% confidence intervals (CI), controlling for potential confounding factors and adjusting for correlation among workers in buildings. This analysis identified associations between building-related symptoms and several indicators of moisture or contamination in office buildings. One set of models showed almost a tripling of weekly building-related lower respiratory symptoms in association with lack of cleaning of the drip pans under air-conditioning cooling coils (OR [CI] = 2.8 (1.2-6.5)). Other models found that lack of cleaning of either drip pans or cooling coils was associated with increased mucous membrane symptoms (OR [CI] = 1.4 (1.1-1.9)). Slightly increased symptoms were also associated with other moisture indicators, especially mucous membrane symptoms and past water damage to building mechanical rooms (OR [CI] = 1.3 (1.0-1.7)). Overall, these findings suggest that the presence of moisture or contamination in ventilation systems or occupied spaces in office buildings may have adverse respiratory or irritant effects on workers. The analysis, however, failed to confirm several risks identified in a previous study, such as condition of drain pans or outdoor air intakes, and other hypothesized moisture risks. Studies with more rigorous measurement of environmental risks and health outcomes will be necessary to define moisture-related risks in buildings.

  18. The value of energy efficiency and accessibility. An analysis of the Dutch office building market; De waarde van energiezuinigheid en bereikbaarheid een analyse van de nederlandse kantorenmarkt

    Energy Technology Data Exchange (ETDEWEB)

    Kok, N. [Departement Financiering, School of Business and Economics, Universiteit Maastricht, Maastricht (Netherlands); Jennen, M. [Departement Financiering, Rotterdam School of Management, Erasmus Universiteit Rotterdam, Rotterdam (Netherlands)

    2011-02-15

    This study offers the first systematic insight in the effects of the main components of sustainability (energy efficiency and accessibility by public transport) on realized rent levels in the Dutch market for office buildings. The rent developments of inefficient and efficient office buildings vary significantly. Accessibility also pays. Both components of sustainability have a direct impact on the value development of both 'non-green' inefficient buildings and of office buildings on traditional single function locations. [Dutch] Dit onderzoek biedt het eerste systematische inzicht in de effecten van de belangrijkste componenten van duurzaamheid (energiezuinigheid en OV-bereikbaarheid) op gerealiseerde huurniveaus in de Nederlandse kantorenmarkt. De huurontwikkelingen van niet zuinige en zuinige kantoorgebouwen lopen sterk uiteen. Ook bereikbaarheid betaalt. Beide componenten van duurzaamheid hebben een directe impact op de waardeontwikkeling van zowel 'niet-groene', onzuinige gebouwen, als op kantoren op traditionele, 'monofunctionele' locaties.

  19. Malaysian Twin Registry.

    Science.gov (United States)

    Jahanfar, Shayesteh; Jaffar, Sharifah Halimah

    2013-02-01

    The National Malaysian Twin Registry was established in Royal College of Medicine, Perak, University Kuala Lumpur (UniKL) in June 2008 through a grant provided by UniKL. The general objective is to facilitate scientific research involving participation of twins and their family members in order to answer questions of health and wellbeing relevant to Malaysians. Recruitment is done via mass media, poster, and pamphlets. We now have 266 adult and 204 children twins registered. Several research projects including reproductive health study of twins and the role of co-bedding on growth and development of children are carried out. Registry holds annual activities for twins and seeks to provide health-related information for twins. We seek international collaboration.

  20. Cost benefit analysis of the night-time ventilative cooling in office building

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli; Fisk, William J.; Faulkner, David

    2003-06-01

    The indoor temperature can be controlled with different levels of accuracy depending on the building and its HVAC system. The purpose of this study was to evaluate the potential productivity benefits of improved temperature control, and to apply the information for a cost-benefit analyses of night-time ventilative cooling, which is a very energy efficient method of reducing indoor daytime temperatures. We analyzed the literature relating work performance with temperature, and found a general decrement in work performance when temperatures exceeded those associated with thermal neutrality. These studies included physiological modelling, performance of various tasks in laboratory experiments and measured productivity at work in real buildings. The studies indicate an average 2% decrement in work performance per degree C temperature rise, when the temperature is above 25 C. When we use this relationship to evaluate night-time ventilative cooling, the resulting benefit to cost ratio varies from 32 to 120.

  1. Modeling of a Novel Low-Exergy System for Office Buildings with Modelica

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Afshari, Alireza; Hultmark, Göran

    2016-01-01

    and simulation environment based on the Modelica programming language. The system was tested on two single office rooms. In order to evaluate potential energy savings, the energy performance of the novel system was compared with the one of a conventional system for three typical weeks during winter, spring...... winter and spring week. No energy savings occurred during the summer week....... and summer. Simulation results showed that the novel system was able to maintain comfortable levels of indoor air temperature in both rooms for all the three typical weeks. In addition, the novel system used approximately 35% and 7% less energy than the conventional system, respectively for the typical...

  2. Solar energy system installed at the North Georgia APDC office building

    Science.gov (United States)

    1979-01-01

    A hydronic, automatic drain-down solar heating and cooling system is described. The system provides solar heat exchange from a 2,001 square foot effective collector area and supplies 65-70 percent of the building's cooling demand, 90-95 percent of the heating demand, and domestic hot water. The acceptance test plan and results, system operation and maintenance, and predicted system performance are presented.

  3. Comparative analysis of environmental performance of an office building using BREEAM and GBL

    OpenAIRE

    2016-01-01

    With rapid economic growth and urban expansion in China, the Chinese building sector is now facing the huge challenge of balancing its energy demand and pollution. In order to minimize the environmental impact, the Ministry of Housing Urban-Rural Development (MOHURD) has set an ambitious energy reduction target requiring that 30% of all new constructions to be green by 2020. This paper presents comparative analysis of two environmental rating systems: the latest version of Chinese Green Bu...

  4. Integral energy concepts for office and residential buildings; Integrale Energiekonzepte fuer Buero- und Wohngebaeude

    Energy Technology Data Exchange (ETDEWEB)

    Velten, W.

    1998-06-01

    It has been confirmed by practical project experience that integral energy concepts are an excellent basis for the construction of energy-efficient buildings. In the extreme case buildings can even be self-sufficient in their energy supply. Uniting the responsibility for the overall energy and technology concept in the hands of a single contractor can help reduce frictional losses between those involved in the planning as well costs. A good example of this is the use of a simulation calculation for the prescribed demonstration of proper heat insulation. The presented projects show that it is possible to construct ecologically answerable buildings at attractively low costs. The presented concepts appear particularly convincing from the viewpoint of long-term maintenance of value and user-specific advantages such as agreeable working conditions. [Deutsch] Die konkreten Projekterfahrungen bestaetigen, dass durch integrale Energiekonzepte sowohl im Verwaltungs- als auch im Wohnungsbau hervorragende Voraussetzungen fuer energiesparende Gebaeude geschaffen werden koennen. Im Extremfall kann sogar eine autarke Energieversorgung erreicht werden. Durch Zusammenfassung der Gesamtverantwortung fuer das Energie- und Technikkonzept in einer Hand koennen Reibungsverluste zwischen den Planungsbeteiligten reduziert und Kosten gesenkt werden. Ein Beispiel hierfuer ist die Verbindung des vorgeschriebenen Waermeschutznachweises mit einer fuer alle Beteiligten wesentlich aussagekraeftigeren Simulationsrechnung. Die vorgestellten Projekte zeigen, dass oekologisch sinnvolle Gebaeude auch zu oekonomisch attraktiven Kosten erstellt werden koennen, wobei insbesondere der Aspekt des langfristigen Werterhalts und die nutzerspezifischen Vorteile, z.B. durch angenehmere Arbeitsbedingungen, fuer die vorgestellten Konzepte spricht. (orig.)

  5. Final report of the decontamination and decommissioning of Building 1 at the Grand Junction Projects Office Facility

    Energy Technology Data Exchange (ETDEWEB)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. Building 1 was found to be radiologically contaminated and was demolished in 1996. The soil beneath and adjacent to the building was remediated in accordance with identified standards and can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  6. Baseline indoor air quality measurements collected from 136 metropolitan New York region commercial office buildings between 1997-1999.

    Science.gov (United States)

    Springston, John P; Esposito, William A; Cleversey, Keith W

    2002-01-01

    Between January 1997 and December 1999, 648 surveys were performed in 136 commercial office buildings in the metropolitan New York region as part of an ongoing proactive indoor environmental quality (IEQ) program. Sampling was performed on a spot basis in "nonproblem" buildings, during normal business hours, either quarterly or semiannually. Carbon dioxide (CO2), carbon monoxide (CO), and total volatile organic compounds (TVOCs) were among the various physical and gaseous parameters sampled for. More than 15,000 data points were collected, and the results were analyzed to determine the mean, median, mode, and standard deviation for each of those parameters. The data was then compared to various standards and/or guidelines applicable to the indoor environment. The results indicated that 98% of the CO2 readings were below 1000 ppm, and 99.9% of the CO readings were below 10 ppm. However, for TVOCs, nearly 88% of the readings exceeded the proposed European guideline value of 0.3 mg/m3. Ultimately, these results can be used to compare both baseline and periodic readings collected in future studies, and to help determine if potential problems exist within a building.

  7. Enhancing Malaysian Teachers' Assessment Literacy

    Science.gov (United States)

    Lian, Lim Hooi; Yew, Wun Thiam; Meng, Chew Cheng

    2014-01-01

    Currently, in order to reform the Malaysian education system, there have been a number of education policy initiatives launched by the Malaysian Ministry of Education (MOE). All these initiatives have encouraged and inculcated teaching and learning for creativity, critical, innovative and higher-order thinking skills rather than conceptual…

  8. FSE - Center for research, training and development. The Siemens Building Technologies office building at Frankfurt, Main; Forschungs-, Schulungs- und Entwicklungszentrum (FSE). Firmengebaeude der Siemens Building Technologies in Frankfurt/Main

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, W.

    2003-07-01

    The new office building of Siemens Building Technologies (SBT) is described. Apart from an impressive architecture, the system also has a state-of-the-art facility management system based on open protocols like Ethernet TCP/IP, BACnet and LONTalk. [German] Als sachlich-technisches Gebaeude mit einem Hang zum Understatement wurde der neue Firmensitz von Siemens Building Technologies (SBT) Deutschland errichtet. Aehnlich wie das Produkt-, System- und Dienstleistungsangebot entspricht das Forschungs-, Schulungs- und Entwicklungszentrum ''FSE'' ganz den Prinzipien Offenheit, Flexibilitaet und Standardisierung. Das in Systembauweise aus Stahlbetonfertigteilen erstellte Gebaeude vermittelt trotz wirtschaftlich orientierter Bescheidenheit ein hohes Mass an Identitaet und sachlicher Repraesentanz. In dem klar strukturierten Baukoerper mit eher klassischer Heizungs- und Lueftungstechnik ist die derzeit wohl modernste gewerkeuebergreifende Gebaeudeautomation installiert, die ganz auf offenen Protokollen wie Ethernet TCP/IP, BACnet und LONTalk aufbaut. (orig.)

  9. Integration of daylight, artificial light and electronic light controls into office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Ehling, K.; Knoop, T.; Aydinli, S.; Kaase, H. [Technical Univ. of Berlin, Inst. of Electronics and Lighting Technology (Germany)

    1996-12-31

    From a technical point of view daylight can be used in two different ways. On the one hand the available daylight can be distributed in an optimised way in order to illuminate deep spaces and to prevent from glare and on the other hand the artificial light can be controlled with respect to the daylight penetrating the room in order to save electrical energy. If these systems are adjusted according to the available daylight both strategies require sensors and logic elements which are supplied by electronic light controls on the basis of building management systems. (orig.)

  10. Solar energy contribution to the energy demand for air conditioning system in an office building under Tripoli climate conditions

    Directory of Open Access Journals (Sweden)

    Musbah Mohamed H.

    2014-01-01

    Full Text Available The feasibility of solar assisted air conditioning in an office building under Tripoli weather conditions is investigated in this paper. A single-effect lithium bromide absorption cycle powered by means of flat-plate solar collectors was modeled in order to predict the potential of the solar energy share. The cooling load profile was generated by using an detailed hourly based program and Typical meteorological year for Tripoli. System performance and solar energy fraction were calculated by varying two major parameters (collector’s slope angle and collector area. The maximum solar fraction of 48% was obtained by means of 1400 m2 of collector surface area. Analysis of results showed that, besides the collector surface area, the main factors affecting the solar fraction were the local weather conditions (intensity of incident solar radiation and the time of day when the plant was operated.

  11. Highlighting High Performance: National Renewable Energy Laboratory's Thermal Test Facility, Golden, Colorado. Office of Building Technology State and Community Programs (BTS) Brochure

    Energy Technology Data Exchange (ETDEWEB)

    Burgert, S.

    2002-10-21

    The National Renewable Energy Laboratory's Thermal Test Facility in Golden, Colorado, was designed using a whole-building approach--looking at the way the building's systems worked together most efficiently. Researchers monitor the performance of the 11,000-square-foot building, which boasts an energy cost savings of 63% for heating, cooling, and lighting. The basic plan of the building can be adapted to many needs, including retail and warehouse space. The Thermal Test Facility contains office and laboratory space; research focuses on the development of energy-efficiency and renewable energy technologies that are cost-effective and environmentally friendly.

  12. The Advantages of the Passive Construction of Office Buildings in the Jiu Valley

    Directory of Open Access Journals (Sweden)

    Andreea Cristina TATARU

    2016-06-01

    Full Text Available The concept of a 'passive House' has been introduced for the first time in Germany, subsequently being extended and at higher latitudes and different features climatic from those of Germany, in the south, west and south-west of Europe. In this paper we strive to study at the concept of 'passive house' in the Jiu Valley (latitude 45.63, and longitude 25.41 Using the Passive House Planning Package (PHPP software 2007 calculate the heating requirements for such a House, depending on the latitude and climate conditions in the locality. It will also analyze the constructive solutions for reduction of the amount of heat below the maximum allowed for a "passive house" (which is 15 kWh/m² per year. Also we will present you which are advantages of construction of this kind of building.

  13. Simulation of temperature in office with building integrated heating and cooling system

    DEFF Research Database (Denmark)

    Weitzmann, Peter

    2002-01-01

    by raising the temperature of the concrete to slightly above the desired room temperature. Another way of solving the problem of cooling is by using building integrated cooling in floors. This technique utilizes the thermal mass of concrete in the floors, by integrating PEX pipes in the floor. By maintaining...... and thermal comfort parameters. The model is based on a numerical Finite Control Volume (FCV) method for the heat transfer in walls, ceiling, windows and floor. The model uses both convective and radiative heat transfer to the room air and between the room surfaces. The simulation model can be used...... for calculating situations with both cooling and heating demands. Using the model it is therefore possible to assess the thermal environment, and furthermore to calculate the energy consumption required for both heating and cooling. In the paper different construction types of the floor are examined, as well...

  14. 办公建筑公共空间的设计与应用%Design and application of public office building space

    Institute of Scientific and Technical Information of China (English)

    陈岩松

    2012-01-01

    Through analyzing several office building cases, the paper summarizes the composition factors of public office building space, studies the design methods of public office building space, and tries various public space design schemes, which has certain referring values for the de- sign practice.%通过对几个办公建筑案例的分析,总结了办公建筑公共空间的构成要素,对办公建筑公共空间的设计方法进行研究,尝试找到适应不同要求的公共空间的设计方案,对设计实践有一定的参考借鉴价值。

  15. On analysis of internal space at modern office buildings%现代办公建筑内部空间分析

    Institute of Scientific and Technical Information of China (English)

    田世河

    2012-01-01

    The paper explores the design for the internal space of modern office buildings,illustrates the design points and purposes of the office buildings at the public space,the office space and the traffic space from the components of the internal space,and points out the humanized design and the scientific and reasonable allocation should be noticed,so as to establish the graceful and comfortable office environment.%针对现代办公建筑内部空间设计进行了探讨,从内部空间组成入手,分别阐述了办公建筑公共空间,办公空间及交通空间的设计要点及目标,指出应注重人性化设计,科学合理布置,以营造优美舒适的办公环境。

  16. The Advantage of Highly Controlled Lighting for Offices and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rubinstein, Francis; Bolotov, Dmitriy; Levi, Mark; Powell, Kevin; Schwartz, Peter

    2008-08-17

    The paper presents results from pilot studies of new 'workstation-specific' luminaires that are designed to provide highly, efficient, customized lighting for open-office cubicles. Workstation specific luminaires have the following characteristics: (1) they provide separate, dimming control of the cubicle's 'ambient' and 'task' lighting components, (2) occupancy sensors and control photosensors are integrated into the fixture's design and operation, (3) luminaires can be networked using physical cabling, microcontrollers and a PC running control software. The energy savings, demand response capabilities and quality of light from the two WS luminaires were evaluated and compared to the performance of a static, low-ambient lighting system that is uncontrolled. Initial results from weeks of operation provide strong indication that WS luminaires can largely eliminate the unnecessary lighting of unoccupied cubicles while providing IESNA-required light levels when the cubicles are occupied. Because each cubicle's lighting is under occupant sensor control, the WS luminaires can capitalize on the fact cubicles are often unoccupied during normal working hours and reduce their energy use accordingly.

  17. Higher energy efficiency in administrative and office buildings. Optimisation of primary energy consumption and economic efficiency; Energieeffiziente Buero- und Verwaltungsgebaeude. Hinweise zur primaerenergetischen und wirtschaftlichen Optimierung

    Energy Technology Data Exchange (ETDEWEB)

    Knissel, J.

    1999-12-15

    The study investigates measures to reduce primary energy consumption in administrative and office buildings and their effects in terms of economic efficiency. An exemplary office building is modernised step by step while recording the changes in the primary energy consumption coefficient. [German] In der vorliegenden Studie wird untersucht, wie weit und mit welchen Massnahmen der Primaerenergiebedarf von Buero- und Verwaltungsgebaeuden gesenkt werden kann und welche Auswirkungen dies auf die Wirtschaftlichkeit hat. Hierzu wird die energetische Ausfuehrungsqualitaet eines einfachen Beispielgebaeudes schrittweise verbessert und die Veraenderung des Primaerenergiekennwertes ermittelt. (orig.)

  18. The effects of climate change on heating energy consumption of office buildings in different climate zones in China

    Science.gov (United States)

    Meng, Fanchao; Li, Mingcai; Cao, Jingfu; Li, Ji; Xiong, Mingming; Feng, Xiaomei; Ren, Guoyu

    2017-06-01

    Climate plays an important role in heating energy consumption owing to the direct relationship between space heating and changes in meteorological conditions. To quantify the impact, the Transient System Simulation Program software was used to simulate the heating loads of office buildings in Harbin, Tianjin, and Shanghai, representing three major climate zones (i.e., severe cold, cold, and hot summer and cold winter climate zones) in China during 1961-2010. Stepwise multiple linear regression was performed to determine the key climatic parameters influencing heating energy consumption. The results showed that dry bulb temperature (DBT) is the dominant climatic parameter affecting building heating loads in all three climate zones across China during the heating period at daily, monthly, and yearly scales (R 2 ≥ 0.86). With the continuous warming climate in winter over the past 50 years, heating loads decreased by 14.2, 7.2, and 7.1 W/m2 in Harbin, Tianjin, and Shanghai, respectively, indicating that the decreasing rate is more apparent in severe cold climate zone. When the DBT increases by 1 °C, the heating loads decrease by 253.1 W/m2 in Harbin, 177.2 W/m2 in Tianjin, and 126.4 W/m2 in Shanghai. These results suggest that the heating energy consumption can be well predicted by the regression models at different temporal scales in different climate conditions owing to the high determination coefficients. In addition, a greater decrease in heating energy consumption in northern severe cold and cold climate zones may efficiently promote the energy saving in these areas with high energy consumption for heating. Particularly, the likely future increase in temperatures should be considered in improving building energy efficiency.

  19. Air Conditioning Energy Saving Methods of Office Building in Nanning City%南宁市办公建筑空调节能途径

    Institute of Scientific and Technical Information of China (English)

    廖瑞海

    2011-01-01

    Based on the public notification of building energy consumption in Guangxi, and the analysis of air conditioning energy consumption of four low - energy office buildings, proposes air conditioning energy saving methods of office building in Nanning City. It is suggested that the capable local government should formulate standards of annual office building energy consumption and incentive methods to encourage all units to explore methods of saving energy actively and reduce office building energy consumption.%根据广西建筑能耗公示的情况,通过分析4栋低能耗办公建筑的空调能耗状况,提出了南宁市办公建筑空调节能途径.建议有条件的地方政府通过制定办公建筑全年能耗标准及奖励办法,来鼓励各单位积极探索节能途径,降低办公建筑能耗.

  20. Reducing Data Center Loads for a Large-Scale, Net Zero Office Building (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-12-01

    Case study highlighting the design, implementation strategies, and continuous performance monitoring of NREL's Research Support Facility data center. In constructing a new research facility for its campus, the National Renewable Energy Laboratory (NREL) project team identified the opportunity to design a world-class, energy-efficient data center to support its operations. NREL's efforts resulted in a highly efficient data center that demonstrated considerable energy savings in its first 11 months of operations. Using legacy data center performance as a baseline, the new facility cut energy use by nearly 1,450,000 kWh, delivering cost savings of approximately $82,000. The data center's average total load was 165 kW less than the legacy center's average total load, resulting in a 60% reduction in overall power. Finally, the limited use of cooling and fan energy enabled the new data center to achieve a 1.16 average power utilization effectiveness (PUE) rating, compared to the legacy data center's PUE of 2.28. The laboratory had been relying on individual servers with an energy utilization rate of less than 5%. NREL employed building best practices, innovative design techniques and energy-efficient technologies to support its energy goals for the new data center. To counteract the extensive heat generated by data center equipment, the laboratory implemented a cooling system using outdoor air and evaporative cooling to meet most of the center's needs. Inside the data center, NREL replaced much of its legacy equipment with new, energy-efficient technology. By exchanging this infrastructure for virtualized blade servers, NREL reduced its server energy footprint by 96%. Additionally, NREL replaced its 80%-efficient uninterruptible power supply (UPS) with a UPS that is 95% efficient; deployed ultra efficient power distribution units (PDU) to handle higher UPS voltages; and implemented vacancy sensors to drive down lighting loads. Using best

  1. Building a Federated Infrastructure for Preservation of and Access to Research Data in the Netherlands: The Front Office-Back Office Model

    NARCIS (Netherlands)

    Doorn, P.K.; Dillo, I.; Witkamp, P.; Katre, Dinesh; Giaretta, David

    2014-01-01

    A federated data infrastructure is emerging in The Netherlands on the basis of the collaborative model proposed in the Riding the Wave report as a framework for the scholarly information system of the future. This federated model is elaborated as a layered front office – back office model, in which

  2. Post Fukushima tsunami simulations for Malaysian coasts

    Science.gov (United States)

    Koh, Hock Lye; Teh, Su Yean; Abas, Mohd Rosaidi Che

    2014-10-01

    The recent recurrences of mega tsunamis in the Asian region have rekindled concern regarding potential tsunamis that could inflict severe damage to affected coastal facilities and communities. The 11 March 2011 Fukushima tsunami that crippled nuclear power plants in Northern Japan has further raised the level of caution. The recent discovery of petroleum reserves in the coastal water surrounding Malaysia further ignites the concern regarding tsunami hazards to petroleum facilities located along affected coasts. Working in a group, federal government agencies seek to understand the dynamics of tsunami and their impacts under the coordination of the Malaysian National Centre for Tsunami Research, Malaysian Meteorological Department. Knowledge regarding the generation, propagation and runup of tsunami would provide the scientific basis to address safety issues. An in-house tsunami simulation models known as TUNA has been developed by the authors to assess tsunami hazards along affected beaches so that mitigation measures could be put in place. Capacity building on tsunami simulation plays a critical role in the development of tsunami resilience. This paper aims to first provide a simple introduction to tsunami simulation towards the achievement of tsunami simulation capacity building. The paper will also present several scenarios of tsunami dangers along affected Malaysia coastal regions via TUNA simulations to highlight tsunami threats. The choice of tsunami generation parameters reflects the concern following the Fukushima tsunami.

  3. Post Fukushima tsunami simulations for Malaysian coasts

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Hock Lye, E-mail: kohhl@ucsiuniversity.edu.my [Office of Deputy Vice Chancellor for Research and Post Graduate Studies, UCSI University, Jalan Menara Gading, 56000 Kuala Lumpur (Malaysia); Teh, Su Yean, E-mail: syteh@usm.my [School of Mathematical Sciences, Universiti Sains Malaysia, 11800 Pulau Pinang (Malaysia); Abas, Mohd Rosaidi Che [Malaysian Meteorological Department, MOSTI, Kuala Lumpur (Malaysia)

    2014-10-24

    The recent recurrences of mega tsunamis in the Asian region have rekindled concern regarding potential tsunamis that could inflict severe damage to affected coastal facilities and communities. The 11 March 2011 Fukushima tsunami that crippled nuclear power plants in Northern Japan has further raised the level of caution. The recent discovery of petroleum reserves in the coastal water surrounding Malaysia further ignites the concern regarding tsunami hazards to petroleum facilities located along affected coasts. Working in a group, federal government agencies seek to understand the dynamics of tsunami and their impacts under the coordination of the Malaysian National Centre for Tsunami Research, Malaysian Meteorological Department. Knowledge regarding the generation, propagation and runup of tsunami would provide the scientific basis to address safety issues. An in-house tsunami simulation models known as TUNA has been developed by the authors to assess tsunami hazards along affected beaches so that mitigation measures could be put in place. Capacity building on tsunami simulation plays a critical role in the development of tsunami resilience. This paper aims to first provide a simple introduction to tsunami simulation towards the achievement of tsunami simulation capacity building. The paper will also present several scenarios of tsunami dangers along affected Malaysia coastal regions via TUNA simulations to highlight tsunami threats. The choice of tsunami generation parameters reflects the concern following the Fukushima tsunami.

  4. Case study : an engineer's perspective on the Robert Redford Building (NRDC headquarters office building), Santa Monica, CA : impact of the integrated project team on a building's success

    Energy Technology Data Exchange (ETDEWEB)

    Bolin, R. [Syska Hennessy Group, New York City, NY (United States)

    2004-07-01

    The Natural Resources Defense Council (NRDC) is a national non-profit organization dedicated to protecting public health and the environment. This paper discusses the creation of its Santa Monica office, an adaptive reuse and expansion of an already existing building. The building was designed to become a net energy provider and net water neutral facility. It was constructed from recycled and recyclable materials and utilized local climate wherever possible. One of the key objectives of the project was to gain Leadership in Energy and Environmental Design (LEED) platinum rating. Details of initial design participants were provided, along with design concept and discussions. Design solutions included: passive lighting and heating; ventilation and air conditioning (HVAC) systems; on-site energy generation; and, rainwater collection cisterns and grey water collection and treatment. Various roadblocks such as regulatory issues concerning water, green building guidelines, staging areas and parking were presented. Details of the building's performance results were given, including water performance, on-site power generation and construction waste management. A comprehensive list of the LEED accreditation results were also provided. It was concluded that factors for success include an early start, involvement with stakeholders, constant communication and knowledgeable contractors. tabs., figs.

  5. Environment-friendly building complex of the BBVA bank in Madrid, Spain. Sustainable and healthy indoor climate in a new office building; Spaans BBVA-cornplex milieuvriendelijk gebouwd. Duurzaam en gezond binnenklimaat nieuw hoofdkantoor

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, G. [Swegon, Capelle aan den IJssel (Netherlands)

    2011-03-15

    In the design and construction of the new office building of the Spanish bank BBVA (Madrid) sustainability and environmental effects were important aspects. The office building complex will certified by the American company Leed Gold. The energy efficient installations are made possible by Eurovent-certified heat recovery units and comfort units. [Dutch] Bij de bouw van het nieuwe hoofdkantoor van de Spaanse bank BBVA in Madrid staan duurzaamheid en milieuvriendelijkheid hoog in het vaandel. Het complex zal na de oplevering worden gecertificeerd conform het Amerikaanse Leed Gold. De energiezuinige installatie wordt mede mogelijk gemaakt door Eurovent-gecertificeerde wtw-units en comfortunits.

  6. Building

    OpenAIRE

    Seavy, Ryan

    2014-01-01

    Building for concrete is temporary. The building of wood and steel stands against the concrete to give form and then gives way, leaving a trace of its existence behind. Concrete is not a building material. One does not build with concrete. One builds for concrete. MARCH

  7. 现代办公建筑中的公共空间设计探讨%Discussion on the Design of Public Space in Modern Office Buildings

    Institute of Scientific and Technical Information of China (English)

    陆建

    2014-01-01

    现代化的办公建筑非常注重公共空间的设计,以求充分利用公共空间,达到现代化的设计目的,为办公人员提供优质的空间服务。本文通过对现代办公建筑的研究,分析了公共空间的设计问题。%The modern office building pays much atention to the design of public space, n order to make full use of public space, to achieve the purpose of modernization, providing qu-ality services for officers. In this paper, through the study of the modern office building, the author analyzed the design of public space.

  8. Human Factors in Green Office Building Design: The Impact of Workplace Green Features on Health Perceptions in High-Rise High-Density Asian Cities

    Directory of Open Access Journals (Sweden)

    Fei Xue

    2016-10-01

    Full Text Available There is a growing concern about human factors in green building, which is imperative in high-rise high-density urban environments. This paper describes our attempts to explore the influence of workplace green features (such as green certification, ventilation mode, and building morphology on health perceptions (personal sensation, sensorial assumptions, healing performance based on a survey in Hong Kong and Singapore. The results validated the relationship between green features and health perceptions in the workplace environment. Remarkably, participants from the air-conditioned offices revealed significant higher concerns about health issues than those participants from the mixed-ventilated offices. The mixed-ventilation design performs as a bridge to connect the indoor environment and outdoor space, which enables people to have contact with nature. Additionally, the preferred building morphology of the workplace is the pattern of a building complex instead of a single building. The complex form integrates the configuration of courtyards, podium gardens, green terrace, public plaza, and other types of open spaces with the building clusters, which contributes to better health perceptions. This research contributes to the rationalization and optimization of passive climate-adaptive design strategies for green buildings in high-density tropical or subtropical cities.

  9. Energy Prediction versus Energy Performance of Green Buildings in Malaysia. Comparison of Predicted and Operational Measurement of GBI Certified Green Office in Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Zaid Suzaini M

    2016-01-01

    Full Text Available Forward from the sustainability agenda of Brundtland in 1987 and the increasing demand for energy efficient buildings, the building industry has taken steps in meeting the challenge of reducing its environmental impact. Initiatives such as ‘green’ or ‘sustainable’ design have been at the forefront of architecture, while green assessment tools have been used to predict the energy performance of building during its operational phase. However, there is still a significant hap between predicted or simulated energy measurements compared to actual operational energy consumption, or is more commonly referred as the ‘performance gap’. This paper tries to bridge this gap by comparing measured operational energy consumption of a Green Building Index (GBI certified office building in Kuala Lumpur, with its predicted energy rating qualification.

  10. Building Footprints, Building footprints, building dimensions, and building data to coincide with Lyon County Appraiser's Office data. This data is NOT complete., Published in 2010, 1:1200 (1in=100ft) scale, City of Emporia/Lyon County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Building Footprints dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Other information as of 2010. It is described as 'Building...

  11. 中国银行忻州市分行营业办公楼设计%The office building design of Xinzhou branch of Bank of China

    Institute of Scientific and Technical Information of China (English)

    牛东伟

    2012-01-01

    以中国银行忻州市分行营业办公楼为例,对此办公楼的项目定位、项目确定过程及建筑方案做了详细的介绍和阐述,为建设生态型的建筑尽可能的节约能源和减小日常能耗,以期为同类项目在运作过程中提供参考。%Taking Xinzhou branch office building of Bank of China as an example, this paper made detailed introduction and elaboration to the project orientation, project identification process and construction scheme of office buildings, for construction of ecotype buildings to save energy and reduce daily energy consumption as much as possible, in order to provide reference for similar projects in operation process.

  12. Modeling a National Collaborative Digital Library for Malaysian Secondary Schools

    Directory of Open Access Journals (Sweden)

    N.N. Edzan

    2004-09-01

    Full Text Available This paper describes the conceptualisation of a model for a collaborative digital library specially tailored for Malaysian secondary schools, which will support classroom teaching and learning. The move towards collaboratively building the contents of a digital library is a fairly recent trend and it simulates an environment where partners are empowered to participate in building and up keeping the knowledge contents of the system. The conceptualisation of a Malaysian digital library is in line with the governments efforts in establishing SMART schools. However, various issues such as identifying local resources, ascertaining the needs of it users, and establishing a framework to meet these needs, must be addressed before the digital library can be fully implemented. It may be approached through the establishment of test beds in a particular learning institution, before nationwide implementation.

  13. Self-reported health and comofrt in modern office buildings: first results from the European Officair study

    NARCIS (Netherlands)

    Bluyssen, P.M.; Roda, C.; Mandin, C.; Fossati, S.; Carrer, P.; Kluizenaar, Y. de; Mihucz, V.G.; Oliveira Fernandes, E. de; Bartzis, J.

    2015-01-01

    In the European research project OFFICAIR, a procedure was developed to determine associations between characteristics of European offices and health and comfort of office workers, through a checklist and a selfadministered questionnaire including environmental, physiological, psychological, and soc

  14. Energy Consumption Charateristics of Existing Office Building in Nanjing%南京市既有办公建筑能耗特点分析

    Institute of Scientific and Technical Information of China (English)

    刘晓静

    2013-01-01

    根据南京市办公建筑的调查,分析了影响建筑能源消耗的因素。这些因素包括了建筑围护结构、暖通空调系统、照明系统、办公设备、综合服务能耗等。通过对因素的分析,阐述了建筑能源消耗与建筑影响因素之间的关系,最终形成了办公建筑能源消耗与影响因素框架图,为深入研究南京市办公建筑能源消耗水平奠定了基础。%Influencing factors of buiding energy consumption are analysed according to the survey of the existing office buildings in Nanjing. These factors include buiding envelope, HVAC, lighting systems, office equipments, integrated services, etc. The relationship between building energy consumption and building influencing factors is expounded and reflected with framework for further study on office building energy consumption in Nanjing.

  15. Malaysian perceptions of China

    Directory of Open Access Journals (Sweden)

    Ibrahim Abu Bakar

    2009-11-01

    Full Text Available Malasia que consistía en Malaya, Sabah, Sarawak y Singapur ganó su independencia de los Británicos el 16 de septiembre de 1963. Malaya ganó su independencia de los británicos el 31 de agosto de 1957. En 1965 Singapur era independiente de Malasia. Malasia es una democracia parlamentaria y capitalista. Por otra parte, es una nación multi-religiosa y multirracial. Malasia ha sido poblada por los Malays, los Chinos, los Indios y otros. Los Malays son musulmanes y el Islam es la religión de la federación de Malasia. La nación tiene una larga historia con China pero esa nunca colonizó ningún área en Malasia. Los estados occidentales, fundamentalmente Portugueses y Olandeses colonizaron ciertas áreas en Malasia y luego los Británicos colonizaron la entera región. La percepción malasiana de China está influenciada por muchos factores internos y externos tales como el factor ideologico-político, el desarrollo económico así como las relaciones y la diplomacia nacionales, regionales e internacionales. Este breve artículo presenta la percepción malasiana de China desde un punto de vista cultural, político y económico._____________ABSTRACT:Malaysia consisting of Malaya, Sabah, Sarawak and Singapore gained her independence from the British on 16 September 1963. Malaya gained her independence from the British on 31 August 1957. In 1965 Singapore was independent from Malaysia. Malaysia is a parliamentary democratic and capitalistic nation. Moreover, Malaysia is a multi-religious and multiracial nation. Malaysia has been populated by the Malays, Chinese, Indians and others. The Malays are Muslims and Islam is the religion of the Federation of Malaysia. Malaysia has a very long history with China but China never colonized any area in Malaysia. The Western nations namely the Portuguese and the Dutch colonized certain areas in Malaysia and then the British colonized the whole Malaysia. Malaysian perceptions of China are influenced by many

  16. Evaluating daylighting effectiveness and occupant visual comfort in a side-lit open-plan office building in San Francisco, California

    OpenAIRE

    Konis, Kyle

    2013-01-01

    The introduction of daylight to reduce electrical lighting energy consumption and to enhance Indoor Environmental Quality is one of the most common claims made for commercial office buildings promoted as “sustainable,” “energy efficient,” “green,” or “high performance.”  However, daylit buildings are rarely studied in use to examine the impact of design strategies on visual comfort, or to examine how occupant modifications to the facade may reduce daylighting effectiveness and visual connecti...

  17. 日本办公建筑的绿色生态设计及其评价%Green eco-design and evaluation of Japanese office buildings

    Institute of Scientific and Technical Information of China (English)

    卢韵琴

    2014-01-01

    介绍了日本2个绿色办公建筑实例及其获得的评价,总结了新建和改建办公建筑的主要绿色技术亮点,阐述了自然采光、可再生能源利用、室内舒适性空调设计等方面的绿色生态设计手法,供国内同行参考与借鉴。%Presents two well-known green office buildings and their appraisal in Japan,summarizes the main green technology used in new and reconstruction office buildings,and expounds the green eco-design methods in the aspects of natural light utilization,renewable energy utilization,indoor comfort air conditioning design etc,providing references for peer designers and engineers.

  18. Scotts Valley Energy Office and Human Capacity Building that will provide energy-efficiency services and develop sustainable renewable energy projects.

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Temashio [Scotts Valley Band of Pomo Indians

    2013-06-28

    The primary goal of this project is to develop a Scotts Valley Energy Development Office (SVEDO). This office will further support the mission of the Tribe's existing leadership position as the DOE Tribal Multi-County Weatherization Energy Program (TMCWEP) in creating jobs and providing tribal homes and buildings with weatherization assistance to increase energy efficiency, occupant comfort and improved indoor air quality. This office will also spearhead efforts to move the Tribe towards its further strategic energy goals of implementing renewable energy systems through specific training, resource evaluation, feasibility planning, and implementation. Human capacity building and continuing operations are two key elements of the SVEDO objectives. Therefore, the project will 1) train and employ additional Tribal members in energy efficiency, conservation and renewable resource analyses and implementation; 2) purchase materials and equipment required to implement the strategic priorities as developed by the Scotts Valley Tribe which specifically include implementing energy conservation measures and alternative energy strategies to reduce energy costs for the Tribe and its members; and 3) obtain a dedicated office and storage space for ongoing SVEDO operations.

  19. Investigation and Analysis on Energy Consumption of Commercial Office Buildings%商务办公建筑能耗调研及分析

    Institute of Scientific and Technical Information of China (English)

    陈晓欣; 李永安

    2016-01-01

    对山东某地区商务办公建筑进行了调研。应用抽样调查的方法,对该地区37个样本量的能耗进行统计处理,得出了该地区单位面积建筑能耗为72.14 kW·h/(m2·a),单位面积供暖能耗为14.74 kgce/(m2·a)。研究结果表明,山东某地区的商务办公建筑在用能方面还存在一些问题,建筑节能潜力较大。这对于科学确定商务办公建筑的能耗指标,进而实施用能超定额加价政策具有一定的参考价值。%The method of sampling investigation is utilized to survey the energy consumption about 37 commercial office buildings in Shandong. The conclusion shows that the building energy consumption per unit area is 72.14 kW·h/(m2·a) and the heating energy consumption per unit area is 14.74 kgce/(m2·a). According to the research, although there are some problems about energy consumption in local commercial office buildings, it shows great potentials in building energy efficiency. The research will determine the energy consumption index for commercial office building scientifically to implement price increasing policy if the energy consumption excesses the quota.

  20. Energy management study: A proposed case of government building

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, Mohamad Zamhari; Nawi, Mohd Nasrun Mohd [School of Technology Management and Logistics, Universiti Utara Malaysia, 06010 Sintok, Kedah (Malaysia); Baharum, Mohd Faizal [School of Building, Housing and Planning, Universiti Sains Malaysia, 11800 Penang (Malaysia)

    2015-05-15

    Align with the current needs of the sustainable and green technology in Malaysian construction industry, this research is conducted to seek and identify opportunities to better manage energy use including the process of understand when, where, and how energy is used in a building. The purpose of this research is to provide a best practice guideline as a practical tool to assist construction industry in Malaysia to improve the energy efficiency of the office building during the post-production by reviewing the current practice of the building operation and maintenance in order to optimum the usage and reduce the amount of energy input into the building. Therefore, this paper will review the concept of maintenance management, current issue in energy management, and on how the research process will be conducted. There are several process involves and focuses on technical and management techniques such as energy metering, tracing, harvesting, and auditing based on the case study that will be accomplish soon. Accordingly, a case study is appropriate to be selected as a strategic research approach in which involves an empirical investigation of a particular contemporary phenomenon within its real life context using multiple sources of evidence for the data collection process. A Government office building will be selected as an appropriate case study for this research. In the end of this research, it will recommend a strategic approach or model in a specific guideline for enabling energy-efficient operation and maintenance in the office building.

  1. Energy management study: A proposed case of government building

    Science.gov (United States)

    Tahir, Mohamad Zamhari; Nawi, Mohd Nasrun Mohd; Baharum, Mohd Faizal

    2015-05-01

    Align with the current needs of the sustainable and green technology in Malaysian construction industry, this research is conducted to seek and identify opportunities to better manage energy use including the process of understand when, where, and how energy is used in a building. The purpose of this research is to provide a best practice guideline as a practical tool to assist construction industry in Malaysia to improve the energy efficiency of the office building during the post-production by reviewing the current practice of the building operation and maintenance in order to optimum the usage and reduce the amount of energy input into the building. Therefore, this paper will review the concept of maintenance management, current issue in energy management, and on how the research process will be conducted. There are several process involves and focuses on technical and management techniques such as energy metering, tracing, harvesting, and auditing based on the case study that will be accomplish soon. Accordingly, a case study is appropriate to be selected as a strategic research approach in which involves an empirical investigation of a particular contemporary phenomenon within its real life context using multiple sources of evidence for the data collection process. A Government office building will be selected as an appropriate case study for this research. In the end of this research, it will recommend a strategic approach or model in a specific guideline for enabling energy-efficient operation and maintenance in the office building.

  2. MH17: the Malaysian experience.

    Science.gov (United States)

    Khoo, L S; Hasmi, A H; Abdul Ghani Aziz, S A; Ibrahim, M A; Mahmood, M S

    2016-04-01

    A disaster is a natural or man-made (or technological) hazard resulting in an event of substantial extent causing significant physical damage or destruction, loss of life, or drastic change to the environment. It is a phenomenon that can cause damage to life and property and destroy the economic, social and cultural life of the people; and overwhelms the capacity of the community to cope with the event. The recent tragic aviation accidents in 2014 involving Malaysia Airlines flights MH370 and MH17 shocked the world in an unprecedented manner. This paper focuses on the Malaysian experience in the MH17 mission in Ukraine as well as the first ever international Disaster Victim Identification (DVI) operation for the Malaysian DVI team. The DVI operations in Hilversum, the Netherlands were well described in stages. The Netherlands' Landelijk Team Forensische Opsporing as the lead DVI team in Hilversum operated systematically, ensuring the success of the whole mission. This paper discusses the lessons learned by the Malaysian team on proper DVI structure, inter- and intra-agency cooperation, facilities planning and set up, logistics and health and safety aspects, as well as effective communication and collaboration with other international delegates. Several issues and challenges faced by the Malaysian team were also documented. In addition, the authors shared views, opinions and recommendations for a more comprehensive DVI operation in the future.

  3. Inclusion in Malaysian Integrated Preschools

    Science.gov (United States)

    Sukumaran, Sailajah; Loveridge, Judith; Green, Vanessa A.

    2015-01-01

    Inclusive education has been introduced through a number of policy developments in Malaysia over the last 10 years but there is little research investigating the extent and nature of inclusive education for preschoolers with special educational needs (SEN). This study surveyed both regular and special education teachers in Malaysian integrated…

  4. Inclusion in Malaysian Integrated Preschools

    Science.gov (United States)

    Sukumaran, Sailajah; Loveridge, Judith; Green, Vanessa A.

    2015-01-01

    Inclusive education has been introduced through a number of policy developments in Malaysia over the last 10 years but there is little research investigating the extent and nature of inclusive education for preschoolers with special educational needs (SEN). This study surveyed both regular and special education teachers in Malaysian integrated…

  5. Suitability Analysis of Office Building Design against Maintenance Cost (Case Study of Serayu Opak River Basin Organization, Yogyakarta Province

    Directory of Open Access Journals (Sweden)

    Mario Puji Hersanto

    2017-09-01

    Full Text Available This study aims to determine the effect of building design's inaccuracy against the cost of maintenance, by taking the research in Serayu Opak River Basin Organization, Water Resources Field and Water Resources Management Center in Yogyakarta Special Region. The first step is to analyze the inaccuracy of building design based on the result of interview and observation during field survey. The second step is to analyze the cost of building maintenance. The third step is to analyze the maintenance costs used to minimize the effects of the inaccurate design of the building. The result shows the inaccuracy of building design in the form of the use of clear glass without coated glass film and the absence of heat insulator on the roof of the building cause the room to become hot. The installation of rain gutters without vertical pipes, toilet facilities in the entire building is not yet complete, inadequate accessibility for persons with disabilities, and inadequate corridor design. There is a small portion of the maintenance budget used for reducing the impact of building design's inaccuracy, so it can be concluded that the design of the building is less meet the requirements of the Government regulations.

  6. 76 FR 13617 - Office of Federal High-Performance Green Buildings (OFHPGB); Notice of GSA Bulletin OFHPGB 2011...

    Science.gov (United States)

    2011-03-14

    ... Bulletins. Dated: January 24, 2011. Kathleen M. Turco, Associate Administrator, Office of Governmentwide...-1522. Please cite OFHPGB Bulletin 2011-OPG-1. Dated: January 24, 2011. Kathleen M. Turco, Associate...

  7. Building Footprints, Building Footprints for City and Village Areas Only, Published in 1996, 1:1200 (1in=100ft) scale, Jefferson County Land Information Office.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Building Footprints dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Orthoimagery information as of 1996. It is described as...

  8. 军事办公建筑被动式节能设计策略%Passive Energy-saving Design Strategies of Military Office Building

    Institute of Scientific and Technical Information of China (English)

    张松; 郭新; 尉中华; 葛为

    2013-01-01

      军事办公建筑的节能设计与使用,对推动节能减排、促进军营建设具有重要意义。通过对被动式节能设计策略的研究,从建筑设计的视角,以军事办公建筑设计为突破口,分析能耗现状,明确设计目标和思路,从空间设计布局、围护结构热工性能、遮阳系统设置、自然通风与自然采光等方面,探讨被动式节能设计策略在军事办公建筑设计中的应用。结合特定环境,寻求贯穿节能设计始终的适宜技术,充分发挥被动式节能技术集成的优势。通过多项节能技术的协同作用,可以强化和扩大节能措施带来的节能效应,在降低能耗的同时创造出健康、舒适、高效的办公环境。%Energy⁃saving design and application of military office building is greatly significant to enhance energy⁃saving and emission⁃reducing and promote barback construction. Through the study of passive energy⁃saving design strategy,and in the perspective of architectural design for military office building,this paper analyzes the present situation of energy consumption and determines design goal and idea,and then discusses the application of passive energy⁃saving design strategy in military office buildings from the space design layout,the maintain structure thermal performance,sunshade system setting,natural ventilation and lighting,etc. In combination with the specific environment,this paper seeks“appropriate technology”throughout the course of the energy⁃saving design of military office building to exert advantages of passive energy⁃saving technologies’integration. Coordinating and working several energy⁃saving technologies together can strengthen and expand energy⁃saving effect,create healthy,comfortable and efficient office environment and reduce energy consumption as well.

  9. Norms to establish the most elementary environmental control system which ensures summer thermal comfort in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kruger, W.; Mathews, E.H. (Pretoria Univ. (ZA). Centre for Experimental and Numerical Thermoflow)

    1992-01-01

    Various types of environmental control systems (ECS) such as natural ventilation, mechanical ventilation, evaporative cooling and full air-conditioning can be used to cool buildings in hot climates. It is not always clear which of these would be the most elementary ECS that would still ensure thermal comfort in a thermally efficient building for a specific climate. No method to establish norms describing a minimum acceptable ECS was found. This paper proposes a method and gives the norms for South African buildings. The norms are based on existing thermally efficient reference buildings. The minimum ECS to provide comfort in the reference building for a specific summer climate is established by means of a novel and easy to use thermal simulation procedure. The design must then ensure thermal comfort in new designs by utilizing this minimum ECS. (author).

  10. 天津地区低能耗办公建筑形体研究%Forms of Office Buildings with Low Energy Consumption in Tianjin Area

    Institute of Scientific and Technical Information of China (English)

    任彬彬; 王一平; 肖少英崔勇

    2015-01-01

    The relationship between the building shape coefficient and building energy consumption in Tianjin area is simulated and analyzed with the software DesignBuilder. Results show the optimized shape coefficient would be helpful to reduce energy consumption in cold region, but the relationship is out of shape coefficient and the energy consumption which should be defined within a certain range. Building energy consumption differences of 6 000 m2 building with different shape coefficients are analyzed to deter-mine the form of office building with the lowest energy consumption in Tianjin area.%利用能耗模拟软件 DesignBuilder 对天津地区建筑体型系数与建筑能耗之间的关系进行模拟分析,研究表明优化寒冷地区建筑的体型系数对降低能耗有一定作用,但体型系数与能耗的关系不成正比关系,应在一定范围内进行界定。同时分析6000 m2不同体型系数建筑能耗差异,依据此数据分析确定天津地区最低能耗的办公建筑形体。

  11. Effect of thermal energy storage in energy consumption required for air conditioning system in office building under the African Mediterranean climate

    Directory of Open Access Journals (Sweden)

    Abdulgalil Mohamed M.

    2014-01-01

    Full Text Available In the African Mediterranean countries, cooling demand constitutes a large proportion of total electrical demand for office buildings during peak hours. The thermal energy storage systems can be an alternative method to be utilized to reduce and time shift the electrical load of air conditioning from on-peak to off-peak hours. In this study, the Hourly Analysis Program has been used to estimate the cooling load profile for an office building based in Tripoli weather data conditions. Preliminary study was performed in order to define the most suitable operating strategies of ice thermal storage, including partial (load leveling and demand limiting, full storage and conventional A/C system. Then, the mathematical model of heat transfer for external ice storage would be based on the operating strategy which achieves the lowest energy consumption. Results indicate that the largest rate of energy consumption occurs when the conventional system is applied to the building, while the lowest rate of energy consumption is obtained when the partial storage (demand limiting 60% is applied. Analysis of results shows that the new layer of ice formed on the surface of the existing ice lead to an increase of thermal resistance of heat transfer, which in return decreased cooling capacity.

  12. SEISMIC DESIGN OF TWO STOREY REINFORCED CONCRETE BUILDING IN MALAYSIA WITH LOW CLASS DUCTILITY

    Directory of Open Access Journals (Sweden)

    MOHD IRWAN ADIYANTO

    2014-02-01

    Full Text Available Since Malaysia is not located in active seismic fault zones, majority of buildings in Malaysia had been designed according to BS8110, which not specify any seismic provision. After experienced several tremors originating from neighbouring countries especially from Sumatra, Indonesia, the Malaysian start to ask questions on integrity of existing structures in Malaysia to withstand the earthquake load. The question also arises regarding the economical effect in term of cost of construction if seismic design has to be implemented in Malaysian construction industry. If the cost is increasing, how much the increment and is it affordable? This paper investigated the difference of steel reinforcement and concrete volume required when seismic provision is considered in reinforced concrete design of 2 storey general office building. The regular office building which designed based on BS8110 had been redesigned according to Eurocode 2 with various level of reference peak ground acceleration, agR reflecting Malaysian seismic hazard for ductility class low. Then, the all frames had been evaluated using a total of 800 nonlinear time history analyses considering single and repeated earthquakes to simulate the real earthquake event. It is observed that the level of reference peak ground acceleration, agR and behaviour factor, q strongly influence the increment of total cost. For 2 storey RC buildings built on Soil Type D with seismic consideration, the total cost of material is expected to increase around 6 to 270%, depend on seismic region. In term of seismic performance, the repeated earthquake tends to cause increasing in interstorey drift ratio around 8 to 29% higher compared to single earthquake.

  13. Data on face-to-face contacts in an office building suggests a low-cost vaccination strategy based on community linkers

    CERN Document Server

    Génois, Mathieu; Fournet, Julie; Panisson, André; Bonmarin, Isabelle; Barrat, Alain

    2014-01-01

    Empirical data on contacts between individuals in social contexts play an important role in the information of models describing human behavior and how epidemics spread in populations. Here, we analyze data on face-to-face contacts collected in an office building. The statistical properties of contacts are similar to other social situations, but important differences are observed in the contact network structure. In particular, the contact network is strongly shaped by the organization of the offices in departments, which has consequences in the design of accurate agent-based models of epidemic spread. We then consider the contact network as a potential substrate for infectious disease spread and show that its sparsity tends to prevent outbreaks of fast-spreading epidemics. Moreover, we define three typical behaviors according to the fraction $f$ of links each individual shares outside its own department: residents, wanderers and linkers. Linkers ($f\\sim 50%$) act as bridges in the network and have large betw...

  14. Building Footprints, Published in 2010, 1:2400 (1in=200ft) scale, Dane County Land Information Office.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Building Footprints dataset, published at 1:2400 (1in=200ft) scale, was produced all or in part from Orthoimagery information as of 2010. Data by this publisher...

  15. Analysis of Heat Transfer Performance about the Office Building Wall%办公建筑围护结构墙体传热性能分析

    Institute of Scientific and Technical Information of China (English)

    李国文; 李国强

    2016-01-01

    The form of office building external envelope affects energy consumption.To analyze the thermal performance of office building construction of dry-fasten stone on external wall, we established mathematical model of the heat transfer based on external envelope and wall, carried out the mathematical simulation used the finite difference method, calculated the index of heat change and energy efficiency by determining the temperature change. The conclusion shows by using the cubic spline interpolation function and mathematical model of the heat transfer that the office building interior wall have better energy-saving effect under different climate environment.%办公建筑的外围护结构型式影响能源消耗.针对外墙为干挂石材的办公建筑墙体进行热工性能分析,建立围护结构与墙体的传热数学模型,采用有限差分法进行仿真.通过监测墙体温度变化分析外围护结构传入到室内热量情况,判定办公建筑墙体围护结构的节能状况.通过采取三次样条插值环境温度函数作为有限差分法的数据,输入传热数学模型,模拟墙体的传热性能,得出如下结论:干挂石材外墙的办公建筑内墙表面温度在不同气候环境下波动不大,节能效果较好.

  16. BIM在某办公楼电气设计中的应用%Application of BIM in Electrical Design in an Office Building

    Institute of Scientific and Technical Information of China (English)

    贺琳; 何穆

    2014-01-01

    Describes the application of BIM technology in electrical design of an office building, introduces the technical features of BIM ( visualiation、exquisite、 informatization、 collaborative design, etc.) and summarizes the advantages and the future direction of BIM design.%通过详述BIM技术在某办公楼工程电气设计中的应用,介绍BIM 技术的特点(可视化、精细化、信息化、协同设计等),总结BIM设计的优势及未来的发展方向。

  17. An annotated bibliography of completed and in-progress behavioral research for the Office of Buildings and Community Systems. [About 1000 items, usually with abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Weijo, R.O.; Roberson, B.F.; Eckert, R.; Anderson, M.R.

    1988-05-01

    This report provides an annotated bibliography of completed and in-progress consumer decision research useful for technology transfer and commercialization planning by the US Department of Energy's (DOE) Office of Buildings and Community Systems (OBCS). This report attempts to integrate the consumer research studies conducted across several public and private organizations over the last four to five years. Some of the sources of studies included in this annotated bibliography are DOE National Laboratories, public and private utilities, trade associations, states, and nonprofit organizations. This study divides the articles identified in this annotated bibliography into sections that are consistent with or similar to the system of organization used by OBCS.

  18. Simulating Single-Effect Absorption Cooling Lithium Bromide A Solar System With Flat Plate Collector And Contribute To An Office Building

    OpenAIRE

    MIRI, Mohadaseh

    2015-01-01

    Use solar energy to provide hot water consumption, space heating and cooling in recent decades is considered. In this article a model varies with time, a solar adsorption cooling system consists of a single effect lithium bromide absorption system, a flat plate collector and a storage tank or linear or parabolic simulated separately. The system for cooling an office building for hours of operation from 7 am to 18 pm is considered.About 7 kW peak cooling load occurs in July. Results obtained s...

  19. Determinants for grading Malaysian rice

    Science.gov (United States)

    ChePa, Noraziah; Yusoff, Nooraini; Ahmad, Norhayati

    2016-08-01

    Due to un-uniformity of rice grading practices in Malaysia, zones which actively producing rice in Malaysia are using their own way of grading rice. Rice grading is important in determining rice quality and its subsequent price in the market. It is an important process applied in the rice production industry with the purpose of ensuring that the rice produced for the market meets the quality requirements of consumer. Two important aspects that need to be considered in determining rice grades are grading technique and determinants to be used for grading (usually referred as rice attributes). This article proposes the list of determinants to be used in grading Malaysian rice. Determinants were explored through combination of extensive literature review and series of interview with the domain experts and practitioners. The proposed determinants are believed to be beneficial to BERNAS in improving the current Malaysian rice grading process.

  20. A Comparative Cradle-to-Gate Life Cycle Assessment of Mid-Rise Office Building Construction Alternatives: Laminated Timber or Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Raymond J. Cole

    2012-07-01

    Full Text Available The objective of this project was to quantify and compare the environmental impacts associated with alternative designs for a typical North American mid-rise office building. Two scenarios were considered; a traditional cast-in-place, reinforced concrete frame and a laminated timber hybrid design, which utilized engineered wood products (cross-laminated timber (CLT and glulam. The boundary of the quantitative analysis was cradle-to-construction site gate and encompassed the structural support system and the building enclosure. Floor plans, elevations, material quantities, and structural loads associated with a five-storey concrete-framed building design were obtained from issued-for-construction drawings. A functionally equivalent, laminated timber hybrid design was conceived, based on Canadian Building Code requirements. Design values for locally produced CLT panels were established from in-house material testing. Primary data collected from a pilot-scale manufacturing facility was used to develop the life cycle inventory for CLT, whereas secondary sources were referenced for other construction materials. The TRACI characterization methodology was employed to translate inventory flows into impact indicators. The results indicated that the laminated timber building design offered a lower environmental impact in 10 of 11 assessment categories. The cradle-to-gate process energy was found to be nearly identical in both design scenarios (3.5 GJ/m2, whereas the cumulative embodied energy (feedstock plus process of construction materials was estimated to be 8.2 and 4.6 GJ/m2 for the timber and concrete designs, respectively; which indicated an increased availability of readily accessible potential energy stored within the building materials of the timber alternative.

  1. The Effect Of Chief Risk Officer (CRO) On Enterprise Risk Management (ERM) Practices: Evidence From Malaysia

    National Research Council Canada - National Science Library

    Wan Norhayate Wan Daud Daud; Ahmad Shukri Yazid; Hj Mohd Rasid Hussin

    2010-01-01

    ...) in Malaysia and the influence of Chief Risk Officers (CROs) on ERM practices. Included in this particular study is a comprehensive survey on 500 companies from the main board of public listed companies in the Malaysian Bourse...

  2. Potential of shading devices and glazing configurations on cooling energy savings for high-rise office buildings in hot-humid climates: The case of Malaysia

    Directory of Open Access Journals (Sweden)

    Allen Khin Kiet Lau

    2016-12-01

    Full Text Available Rapid growing of energy use has raised critical concerns over energy supply difficulties and negative environmental impacts globally and among ASEAN countries. Malaysia is experiencing a high average annual energy demand growth rate of approximately 2.3% which large portion of that energy is used by office buildings. Under the hot-humid climatic conditions in Malaysia, high-rise office buildings with large or fully glazed façades are facing a major problem of overheating due to high solar radiation through the glazed façades. This has caused high cooling energy requirements. The aim of this study is to investigate the potential of three types of shading devices on cooling energy savings when applied at different façade orientations. The aim also extends to investigations on different cooling energy savings when shading devices are applied on façade glazing with different configurations and thermal performances. This was done through a case study of a high-rise office building in Kuala Lumpur, Malaysia using IES (VE building thermal simulation software. Twenty simulation building models were applied with different shading devices at different façade orientations and with high and low performance façade glazing. The simulation results indicate that high-rise office buildings in Malaysia use approximately 45.9% of total building energy for cooling purposes. The results also suggest that use of various shading devices on low-e double glazed façades will result between 1.0% and 3.4% annual cooling energy savings, depending on the types of shading devices and façade orientations. The estimated annual cooling energy savings increase to between 5.0% and 9.9% when the shading devices are applied to all orientations of low-e double glazed façades. The estimated annual cooling energy savings further increase to between 5.6% and 10.4% when the façade glazing is replaced by single clear glazing. This study recommends prioritizing shading devices on

  3. Safe space. How you can define fair market value for medical-office building lease agreements with hospitals.

    Science.gov (United States)

    Murray, Chuck

    2007-04-01

    When entering into office-space lease agreements with hospitals, physician practice administrators need to pay close attention to the federal antikick-back statute and the Stark law. Compliance with these regulations calls for adherence to fair market value and commercial reasonableness--blurry terms open to interpretation. This article provides you with a framework for defining fair market value and commercial reasonableness in regard to real-estate transactions with hospitals.

  4. Out of Office: A Study on the Cause of Office Vacancy and Transformation as a Means to Cope and Prevent

    OpenAIRE

    Remøy, H.

    2010-01-01

    Office building vacancy is becoming an increasingly visible part of the cityscape. Billboards shout “for rent” and office locations look abandoned even in the middle of the day. Still, new office buildings and locations are being developed, adding up to the built environment. As hardly any office buildings are demolished, adapted or transformed, the vacancy increases. Office buildings are developed though there is no demand for new office buildings. Or…is there? New office buildings seem to b...

  5. Optimization design and compare of different solar-ground source heat pump system of office building in cold regions

    Science.gov (United States)

    Xie, H.; He, S.; Fu, Y.

    2016-08-01

    This paper presents two different operation modes of Solar-Ground Source Heat Pump System (SGSHP(S)). With the simulation tool TRNSYS, two different SGSHP system models were built to taking simulation. After making analysis and compare of different simulation results, series operation mode was believed to be better than parallel in the target building.

  6. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated

  7. Rhythmic patterning in Malaysian and Singapore English.

    Science.gov (United States)

    Tan, Rachel Siew Kuang; Low, Ee-Ling

    2014-06-01

    Previous work on the rhythm of Malaysian English has been based on impressionistic observations. This paper utilizes acoustic analysis to measure the rhythmic patterns of Malaysian English. Recordings of the read speech and spontaneous speech of 10 Malaysian English speakers were analyzed and compared with recordings of an equivalent sample of Singaporean English speakers. Analysis was done using two rhythmic indexes, the PVI and VarcoV. It was found that although the rhythm of read speech of the Singaporean speakers was syllable-based as described by previous studies, the rhythm of the Malaysian speakers was even more syllable-based. Analysis of the syllables in specific utterances showed that Malaysian speakers did not reduce vowels as much as Singaporean speakers in cases of syllables in utterances. Results of the spontaneous speech confirmed the findings for the read speech; that is, the same rhythmic patterning was found which normally triggers vowel reductions.

  8. The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity.

    Science.gov (United States)

    Wargocki, P; Wyon, D P; Sundell, J; Clausen, G; Fanger, P O

    2000-12-01

    Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.

  9. Control strategies study of a complete solar assisted air conditioning system in an office building using TRNSYS

    OpenAIRE

    Thomas, Sébastien; Andre, Philippe

    2009-01-01

    It is now clearly assumed that solar assisted air conditioning is able to minimize environmental impact and CO2 production of buildings operation. How to reach highest energy savings is still a work in progress. In former literature, equipment control has been point out as a critical feature of energy consumption. Control becomes more and more important as system is complex. The complete simulation environment was developed in previous work, it includes the absorption chiller ...

  10. Numerical simulation and performance assessment of an absorption solar air-conditioning system coupled with an office building

    OpenAIRE

    Thomas, Sébastien; Andre, Philippe

    2010-01-01

    To minimize environmental impact and CO2 production associated with air-conditioning, it is reasonable to evaluate the prospects of a clean energy source. Solar energy, via thermal collectors can provide a part of the heating needs. Moreover, it can drive absorption chiller in order to satisfy the cooling needs of buildings. The objective of the work is to evaluate accurately the energy consumption of an air conditioning system including a solar driven absorption chiller. The c...

  11. Plug-in Electric Vehicle Interactions with a Small Office Building: An Economic Analysis using DER-CAM

    Energy Technology Data Exchange (ETDEWEB)

    Momber, Ilan; Gomez, Tom& #225; s; Venkataramanan, Giri; Stadler, Michael; Beer, Sebastian; Lai, Judy; Marnay, Chris; Battaglia, Vincent

    2010-06-01

    It is generally believed that plug-in electric vehicles (PEVs) offer environmental and energy security advantages compared to conventional vehicles. Policies are stimulating electric transportation deployment, and PEV adoption may grow significantly. New technology and business models are being developed to organize the PEV interface and their interaction with the wider grid. This paper analyzes the PEVs' integration into a building's Energy Management System (EMS), differentiating between vehicle to macrogrid (V2M) and vehicle to microgrid (V2m) applications. This relationship is modeled by the Distributed Energy Resources Customer Adoption Model (DER-CAM), which finds optimal equipment combinations to meet microgrid requirements at minimum cost, carbon footprint, or other criteria. Results derive battery value to the building and the possibility of a contractual affiliation sharing the benefit. Under simple annual fixed payments and energy exchange agreements, vehicles are primarily used to avoid peak demand charges supplying cheaper off-peak electricity to the building during workdays.

  12. Results and experience of an aquifer thermal energy storage for heating and cooling of an office building and a demonstration center

    Energy Technology Data Exchange (ETDEWEB)

    Bael, Johan van; Desmedt, Johan; Vanhoudt, Dirk [Vlaamse Instelling voor Technologisch Onderzoek (VITO), Mol (Belgium)

    2010-07-01

    Aquifer Thermal Energy Storage (ATES) was introduced in the Belgian market since 1995. Until now over 10 installations with a thermal power of more than 300 kW cooling are installed. One of the first projects consists of the integration of ATES with a nominal power of 570 kWh in an existing office building and a new built demonstration center (3,000 m{sup 2}) for new lighting systems. The ATES system exists of a doublet: a cold and a warm well. The groundwater flow between the wells amounts to 90 m{sup 3}/h in the cooling modus and 45 m{sup 3}/h in the heating modus. The ATES system delivers the complete cooling demand of both buildings and a part of the heating demand. A gas fired boiler delivers the remaining heat demand. The project was funded by the Flemish Government in the Program of the Flemish Energy Demonstration Projects. The research institute VITO monitored the project during an evaluation period of three years. The energy flows (cooling and heating delivered to both buildings), the groundwater flow, the groundwater temperatures, the electricity consumption of the ATES and the gas consumption of the boiler were measured and stored every 30 minutes. This paper provides an overview of the monitoring results. (orig.)

  13. Assessment of Carbon Emission Reduction for Buildings Projects in Malaysia-A Comparative Analysis

    Directory of Open Access Journals (Sweden)

    Klufallah Mustafa M. A.

    2014-01-01

    Full Text Available The Malaysian construction industry significantly contributes as an empowerment to its development vision of 2020 by reducing 40% of carbon emission. Moreover, this industry accounts as a threat to the environment, not only in terms of consumption of natural resources but also in emitting million tons of carbon emission annually. In fact, Malaysia is categorized the 30th in the world's ranking in carbon emission level. To mitigate the raise of carbon emission level from the buildings construction, several studies identified some of the effective carbon emission assessment tools for construction projects but it is lack of implementation in Malaysia. The green building index (GBI, Malaysian CIB Report has been introduced to assist the construction stakeholders in reducing the level of carbon emission and the impact of buildings on the environment. This paper presents an analysis of carbon emission from housing projects and office buildings in order to identify and quantify the main sources of carbon emission for each project and it proposes environmental friendly materials as replacement for conventional construction materials to achieve the implementation of sustainability in Malaysia.

  14. Study on Health Management Method for Office Workers in City Buildings%城市楼宇办公人员健康管理方法研究

    Institute of Scientific and Technical Information of China (English)

    李莉; 丁玎

    2012-01-01

    [目的]通过对楼宇员工健康现况的调查、健康干预,评价在楼宇开展办公人员健康管理方法的有效性. [方法]对467名城市办公人员开展问卷调查、健康体检,将其中137名脂代谢和糖代谢障碍的办公人员分为干预组64人和对照组73人,进行综合性健康干预. [结果]经综合健康管理模式干预后的健康知识知晓率较干预前提高了11.7%,与对照组相比有明显提高. [结论] “三级医院技术指导—社区卫生服务中心实施与管理—街道相关部门协调支持—楼宇办公人员积极参与”的新型综合健康管理模式在健康促进方面有显著效果.楼宇健康管理应根据办公人员主要健康问题和需求,由社区卫生服务中心制定健康管理计划,协同楼宇工会、街道办事处等机构部门合作完成.%[Objective ] To compare health status of office workers in city buildings before and after health interventions, and to evaluate effectiveness of health management conducted in commercial buildings. [ Methods ] A total of 467 office workers participated in a questionnaire survey and physical examination, in which 137 with lipid metabolism and glucose metabolism disorders were divided into an intervention group (64) and a control group (73). The latter group received an integrated health intervention. [ R6SUltS ] After intervention, the awareness rate of health knowledge in the intervention group was significantly increased by 11.7%, compared with the control group. [ Conclusion ] The new mndel of integrated health management, which is technically directed by tertiary hospitals, implemented and managed by community health center, coordinated and supported by sub-district departments, and actively involves office workers, showed remarkable results on health promotion. Health management for office workers should be based on their major health problems and demands and be carried out with joint efforts of sectors mentioned above.

  15. Construction of a new office building with electronic data processing centre in Munich; Neubau eines Geschaeftsgebaeudes mit Rechenzentrum in Muenchen

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1996-03-01

    At present mainly digital automatic control engineering systems are applied in the field of technical building equipment. The functions of the measuring technique and automatic control engineering are processed on a field, an automation and a management level. The present contribution gives an overview of all steps of the planning phase (request for tenders, awarding, reimbursement for engineering works). (BWI) [Deutsch] In der Technischen Gebaeudeausruestung werden heute ueberwiegend digitale Regelungs- und Steuerungsanlagen eingesetzt. Die Funktionen der Mess-, Steuer- und Regelungstechnik werden in der Feld-, Automations- und Managementebene verarbeitet. Der vorliegende Beitrag gibt einen Ueberblick ueber alle Stufen der Planungsphase (Ausschreibung, Vergabe, Verguetung von Ingenieursleistungen). (BWI)

  16. ANALYSIS ON ENERGY SAVING POTENTIAL OF BUILDING EXTERIOR ENVELOPE IN OFFICE BUILDINGS IN GUANGZHOU%广州地区办公建筑围护结构节能潜力分析

    Institute of Scientific and Technical Information of China (English)

    刘嘉玲; 左政; 胡文斌

    2013-01-01

    In th is paper, the software of eQUEST3.55 was used to research the influence of the performance of the exterior envelope on the building cooling load in office buildings in Guangzhou. Then analyze the contribution for the air conditioning load energy saving ratio. The result indicated that office building palisade structure energy saving make a reasonable contribution to the implementation of the green construction related evaluation standard energy saving rate. According to the current technology, this paper puts forward tow design schemes which can realize the most largest energy saving rate, the conventional energy-saving technology scheme and high-end energy-saving technology scheme. The results show than the reasonable range of envelope energy conservation contribution is 52%~54%.%利用能耗模拟分析软件eQUEST3.55研究广州地区办公建筑围护结构热工参数对建筑空调负荷的影响,分析其对建筑空调负荷节能率的贡献.结果表明,优化办公建筑围护结构是实现绿色建筑相关评价标准节能率比较有效合理的途径.基于目前节能技术,提出采用常规节能技术和较高端节能技术两种方案,分析得出围护结构节能贡献的合理范围为52%~54%.

  17. Building a quality culture in the Office of Space Flight: Approach, lessons learned and implications for the future

    Science.gov (United States)

    Roberts, C. Shannon

    The purpose of this paper is to describe the approach and lessons learned by the Office of Space Flight (OSF), National Aeronautics and Space Administration (NASA), in its introduction of quality. In particular, the experience of OSF Headquarters is discussed as an example of an organization within NASA that is considering both the business and human elements of the change and the opportunities the quality focus presents to improve continuously. It is hoped that the insights shared will be of use to those embarking upon similar cultural changes. The paper is presented in the following parts: the leadership challenge; background; context of the approach to quality; initial steps; current initiatives; lessons learned; and implications for the future.

  18. Building a quality culture in the Office of Space Flight: Approach, lessons learned and implications for the future

    Science.gov (United States)

    Roberts, C. Shannon

    1992-01-01

    The purpose of this paper is to describe the approach and lessons learned by the Office of Space Flight (OSF), National Aeronautics and Space Administration (NASA), in its introduction of quality. In particular, the experience of OSF Headquarters is discussed as an example of an organization within NASA that is considering both the business and human elements of the change and the opportunities the quality focus presents to improve continuously. It is hoped that the insights shared will be of use to those embarking upon similar cultural changes. The paper is presented in the following parts: the leadership challenge; background; context of the approach to quality; initial steps; current initiatives; lessons learned; and implications for the future.

  19. Application of solar technology in design of office buildings of cold regions%严寒地区办公建筑太阳能技术应用研究

    Institute of Scientific and Technical Information of China (English)

    赵晖

    2012-01-01

    以公共建筑类型中具有代表性的办公建筑为研究对象,采用计算机模拟设计系统及数学理论分析的方法,总结出办公建筑体型设计与太阳辐射间的线性关系,确定了建筑体型系数为办公建筑太阳能技术应用的设计依据.%The cold application of solar energy technology in the office building is a feasible solution to make 75% building energy efficiency,this study based on the office building adopt computer simulation design and mathematical theory analysis, which summarize the linear relationship between the office building shape design and solar radiation, therefore, it determine building shape coefficient to design basis for the application of solar energy technology in the office building.

  20. Lactose tolerance and intolerance in Malaysians

    Directory of Open Access Journals (Sweden)

    Peter Michael Barling

    2012-07-01

    Full Text Available This review explores the digestibility oflactose by Malaysians, and the value of milk and othermilk-derived products as sources of appropriate nutritionfor Malaysians. Increased calcium intake throughconsumption of milk is an effective mechanism forincreasing calcium uptake from the diet and therebyminimising the risk of development of osteoporosis inlater life. Detailed information about rates of lactoseintolerance, and adaptation to dietary lactose andits consequences for Malaysians, will help in theformulation of dietary advice, and improve commerialfood manufaturing practice and Government policydirected to the minimization of rates of osteoporosis,which presents a substantial morbidity risk to elderlyfemale Asians in particular.

  1. Limitations for thermal loads in office buildings with ventilation through windows; Grenzen der thermischen Last bei Fensterlueftung in Buerogebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Zeidler, O. [Klima-Konzept Ingenieurgesellschaft, Berlin (Germany)

    2001-07-01

    Within the framework of a Ph.D. thesis at the Hermann-Rietschel-Institute, Technical University Berlin experimental and analytic studies for the ventilation with openable windows were made. The results describe the possibilities and limits for free ventilation by windows. They can be a basis for the decision to install an HVAC-System or not. With a special building design and reduced cooling loads the period of using the ventilation by windows can be extended. (orig.) [German] Im Rahmen einer Dissertation am Hermann-Rietschel-Institut der Technischen Universitaet Berlin wurden experimentelle und analytische Untersuchungen durchgefuehrt, um Moeglichkeiten und Grenzen der Fensterlueftung darzustellen. Die Ergebnisse der Untersuchungen geben Entscheidungshilfen im Hinblick auf die Notwendigkeit einer RLT-Anlage. Durch eine entsprechende Gebaeudekonstruktion und durch die Reduzierung der Kuehllasten besteht die Moeglichkeit, den jaehrlichen Einsatzzeitraum fuer Fensterlueftung zu verlaengern. (orig.)

  2. Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight

    DEFF Research Database (Denmark)

    Nielsen, Martin Vraa; Svendsen, Svend; Bjerregaard Jensen, Lotte

    2011-01-01

    The façade design is and should be considered a central issue in the design of energy-efficient buildings. That is why dynamic façade components are increasingly used to adapt to both internal and external impacts, and to cope with a reduction in energy consumption and an increase in occupant com...... solar shading, which emphasises the need for dynamic and integrated simulations early in the design process to facilitate informed design decisions about the façade....... components by using integrated simulations that took energy demand, the indoor air quality, the amount of daylight available, and visual comfort into consideration. Three types of façades were investigated (without solar shading, with fixed solar shading, and with dynamic solar shading), and we simulated...

  3. OfficeVISION; OfficeVISION

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    OfficeVISION is a wide range of projects with the same goal: development of technology meeting future demands for good working conditions, health, environment- and energy conservation, the increased productivity. This project shows if it in few years will be possible to build with an energy producing building envelope in high-insulated glass. The officeVISION project is however so visionary that the Technological Institute will have to wait wait some years to build the house until the necessary building components has gone into production. Though the construction is deferred a number of interesting results have come out of the project. By designing a wide range of solutions to the energy producing glass building envelope, we have gradually gotten a good grasp of arrangement possibilities and use of glass buildings. There are many possibilities in this type of construction especially as regards to daylight. But there is also limitations as regards to acoustic and the possibility to use IT presentation screens. Thus the conclusion is that glass buildings are suitable as frames around informal meetings and thought fulness, but hardly the answer to all challenges in the future office. The main objects are: Good daylight conditions; Minimal energy consumption and maximal solar-electricity; Optimum conditions for high productivity in the office function; Good healthy indoor climate and good comfort; Export design high productive building technology; Minimal environmental impact; and A landmark for Technological Institute's technological spearheads. (EHS)

  4. Study of Managerial Challenges Confronting a New Agency: The Case of the Malaysian Maritime Enforcement Agency

    Science.gov (United States)

    2015-06-01

    Tun Abdullah Haji Ahmad Badawi 46. Regulatory Office of Federal Land Development Authority 47. Federal Land Development Authority 48. Public... wind makes for the most suitable locations to set up the port. The main ports are Port Klang in Selangor, Pasir Gudang Port and Tanjung Pelepas in...and had been chartered by the Malaysian state-owned oil-and-gas company, Petronas. While it was some miles offshore , an explosives-laden dinghy

  5. Towards e-Government: End-User Satisfaction with IT Implementation at Royal Malaysian Customs

    OpenAIRE

    Abbul Hamid Abu Bakar; Chong Siong Choy; Binshan Lin; Najmi Mohd Radzi

    2014-01-01

    This paper examines the extent of end-user satisfaction on the service delivery process by the Royal Malaysian Customs (RMC) as the agency moves toward implementing electronic government (e-government) initiatives. The RMC has in fact been identified as one of the prominent and technology-pioneering government agencies in the country and therefore suitable for delivering electronic public services. Data were collected in mid-2009 from two types of customers, i.e., internal (Customs officers) ...

  6. Macroeconomic determinants of Malaysian stock market

    National Research Council Canada - National Science Library

    Aisyah Abdul Rahman; Noor Zahirah Mohd Sidek; Fauziah Hanim Tafri

    2009-01-01

    .... Upon testing a vector error correction model, we show that changes in Malaysian stock market index do perform a co-integrating relationship with changes in money supply, interest rate, exchange rate...

  7. Local learning processes in Malaysian industry

    DEFF Research Database (Denmark)

    Wangel, Arne

    1999-01-01

    Local learning processes are a vital part of any dynamic assimilation of transferred technology. The paper raises the question about the interaction between the training paradigms, which transnational corporations introduce in their subsidiaries in Malaysia and the specific basis for learning...... of Malaysian labour. Experiences from Malaysian industry indicate that local learning processes are shaped, among other things, by the concept of knowledge in a particular training programme, labour market structures, and learning cultures....

  8. Final Year Undergraduates' Perceptions of the Integration of Soft Skills in the Formal Curriculum: A Survey of Malaysian Public Universities

    Science.gov (United States)

    Devadason, Evelyn Shyamala; Subramaniam, Thirunaukarasu; Daniel, Esther Gnanamalar Sarojini

    2010-01-01

    A recent initiative or skill bridging measure taken by the Malaysian public universities is to build into the formal curriculum soft skills to produce graduates with a right balance of diverse abilities. However, to date, there is no comprehensive attempt to review the integration of soft skills in the formal curriculum (both coursework and…

  9. Suicidal ideation among Malaysian adolescents.

    Science.gov (United States)

    Ahmad, NoorAni; Cheong, Siew Man; Ibrahim, Nurashikin; Rosman, Azriman

    2014-09-01

    Adolescence is the time of greatest risk for the first onset of suicidal behaviors. This study aimed to identify the risk and protective factors associated with suicidal ideation among Malaysian adolescents. Data from the 2012 Malaysia Global School-based Student Health Survey, a nationwide study using a 2-stage cluster sampling design, were analyzed. The survey used a self-administered validated bilingual questionnaire and the Depression Anxiety and Stress Scale. The prevalence of suicidal ideation was 7.9%. Analysis revealed that suicidal ideation was positively associated with depression, anxiety, stress, substance use, being bullied, and being abused at home, either physically or verbally. In addition, suicidal ideation was significantly higher among females and among the Indians and Chinese. Having close friends and married parents were strongly protective against suicidal ideation. Understanding the risk and protective factors is important in providing comprehensive management for suicidal ideation. © 2014 APJPH.

  10. A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Apte, Joshua S.

    2010-04-27

    The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rank among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in

  11. A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Apte, Joshua S.

    2010-04-27

    The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rank among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in

  12. 办公楼中水回用成本效益分析%Cost-benefit Analysis of Gray Water Recycling Utilized in Office Building

    Institute of Scientific and Technical Information of China (English)

    左婷婷; 袁岩; 王利生

    2013-01-01

      中水回用系统节省淡水资源,缓解城市给排水压力,社会效益显著。但是在经济效益层面,中水回用系统存在争议。针对北京地区办公楼中水回用问题,采用动态投资回收期分析法,结合对未来水价、电价的走势和维保费的模拟,针对Matlab软件计算结果,分析并讨论了中水系统在办公楼中的成本效益。结果表明,目前办公楼中水系统不具备经济投资效益;水价以及运行、维保费的增长率是影响中水回用系统经济效益的主要因素。但随着中水回用系统投入使用的推移,动态投资回收期在减少。到2021年以后中水回用系统投入使用,开始具备经济投资效益。%Gray water recycling system reserves water resource and relieves pressure of municipal water and wastewater which has great potential social benefit. However,gray water recycling system rises controversy in terms of economic benefit. Focusing on gray water recycling system in a research office building located in Beijing,cost-benefit analysis of gray water recycling in the research office building is analyzed and discussed in terms of using dynamic investment pay-back period method solved by Matlab software which combines the simulation of future running water prices,electricity prices and operating& maintenance fees. At present, economic investment of gray water recycling system is turned out to be in vain. Running water prices and increasing rate of operating& maintenance fees are the key factors which have a serious influence on economic benefit of gray water recycling system. With delay of implementation of gray water recycling system,dynamic investment pay-back period is decreasing. Economic investment efficiency of gray water recycling system emerges when the system implements after 2021.

  13. Development and demonstration of Denmark's first low-energy class 1 office building with focus on electricity consumption. Final report; Udvikling og demonstration af Danmarks foerste lavenergiklasse 1 kontorbyggeri med fokus pae elforbrug. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Stephansen, C. [En2tech, Skanderborg (Denmark); Nellemose Knudsen, H. [Aalborg Univ., Statens Byggeforskningsinstitut (SBi), Koebenhavn (Denmark); Busk Rohde, T. [EnergiMidt, Silkeborg (Denmark); Nielsen, Allan [Insight Building Automation, Silkeborg (Denmark)

    2012-12-15

    The company EnergiMidt's new office building is established as a low-energy class 1 building, and although it has shown a significantly higher consumption than expected in the first 1.5 years of operation, extensive experience and knowledge of the development and implementation of a low-energy class 1 building was provided, as well as of the possibilities for improvements so that low energy requirements can realistically be achieved. Employees' expectations for the new systems and indoor climate are largely met, but considerable experience is also gained about how to introduce and adapt new technology in the workplace for the employees. (LN)

  14. Drinking water quality and formation of biofilms in an office building during its first year of operation, a full scale study.

    Science.gov (United States)

    Inkinen, Jenni; Kaunisto, Tuija; Pursiainen, Anna; Miettinen, Ilkka T; Kusnetsov, Jaana; Riihinen, Kalle; Keinänen-Toivola, Minna M

    2014-02-01

    Complex interactions existing between water distribution systems' materials and water can cause a reduction in water quality and unwanted changes in materials, aging or corrosion of materials and formation of biofilms on surfaces. Substances leaching from pipe materials and water fittings, as well as the microbiological quality of water and formation of biofilms were evaluated by applying a Living Lab theme i.e. a research in a real life setting using a full scale system during its first year of operation. The study site was a real office building with one part of the building lined with copper pipes, the other with cross-linked polyethylene (PEX) pipes thus enabling material comparison; also differences within the cold and hot water systems were analysed. It was found that operational conditions, such as flow conditions and temperature affected the amounts of metals leaching from the pipe network. In particular, brass components were considered to be a source of leaching; e. g. the lead concentration was highest during the first few weeks after the commissioning of the pipe network when the water was allowed to stagnate. Assimilable organic carbon (AOC) and microbially available phosphorus (MAP) were found to leach from PEX pipelines with minor effects on biomass of the biofilm. Cultivable and viable biomass (heterotrophic plate count (HPC), and adenosine triphosphate (ATP)) levels in biofilms were higher in the cold than in the hot water system whereas total microbial biomass (total cell count (DAPI)) was similar with both systems. The type of pipeline material was not found to greatly affect the microbial biomass or Alpha-, Beta- and Gammaproteobacteria profiles (16s rRNA gene copies) after the first one year of operation. Also microbiological quality of water was found to deteriorate due to stagnation.

  15. Reducing Data Center Loads for a Large-Scale, Low-Energy Office Building: NREL's Research Support Facility (Book)

    Energy Technology Data Exchange (ETDEWEB)

    Sheppy, M.; Lobato, C.; Van Geet, O.; Pless, S.; Donovan, K.; Powers, C.

    2011-12-01

    This publication detailing the design, implementation strategies, and continuous performance monitoring of NREL's Research Support Facility data center. Data centers are energy-intensive spaces that facilitate the transmission, receipt, processing, and storage of digital data. These spaces require redundancies in power and storage, as well as infrastructure, to cool computing equipment and manage the resulting waste heat (Tschudi, Xu, Sartor, and Stein, 2003). Data center spaces can consume more than 100 times the energy of standard office spaces (VanGeet 2011). The U.S. Environmental Protection Agency (EPA) reported that data centers used 61 billion kilowatt-hours (kWh) in 2006, which was 1.5% of the total electricity consumption in the U.S. (U.S. EPA, 2007). Worldwide, data centers now consume more energy annually than Sweden (New York Times, 2009). Given their high energy consumption and conventional operation practices, there is a potential for huge energy savings in data centers. The National Renewable Energy Laboratory (NREL) is world renowned for its commitment to green building construction. In June 2010, the laboratory finished construction of a 220,000-square-foot (ft{sup 2}), LEED Platinum, Research Support Facility (RSF), which included a 1,900-ft{sup 2} data center. The RSF will expand to 360,000 ft{sup 2} with the opening of an additional wing December, 2011. The project's request for proposals (RFP) set a whole-building demand-side energy use requirement of a nominal 35 kBtu/ft{sup 2} per year. On-site renewable energy generation will offset the annual energy consumption. To support the RSF's energy goals, NREL's new data center was designed to minimize its energy footprint without compromising service quality. Several implementation challenges emerged during the design, construction, and first 11 months of operation of the RSF data center. This document highlights these challenges and describes in detail how NREL successfully

  16. Empirical Essays on Office Market Dynamics

    NARCIS (Netherlands)

    M.G.J. Jennen (Maarten)

    2008-01-01

    textabstractOffice buildings are a major investment vehicle, provide a working environment for numerous employees across the globe and determine the skyline of major cities. Put differently: office buildings matter. This dissertation consists of six studies and focuses on office buildings from a bro

  17. Empirical Essays on Office Market Dynamics

    NARCIS (Netherlands)

    M.G.J. Jennen (Maarten)

    2008-01-01

    textabstractOffice buildings are a major investment vehicle, provide a working environment for numerous employees across the globe and determine the skyline of major cities. Put differently: office buildings matter. This dissertation consists of six studies and focuses on office buildings from a

  18. Managing Political Information: A Malaysian Perspective

    Directory of Open Access Journals (Sweden)

    Jamilah Ahmad

    2010-07-01

    Full Text Available In the development of democratization and the expression of civil and political rights of Malaysian citizens, the pattern of control developed by the regime that is currently in power (Barisan Nasional for the last 50 years in the mass media began to reap the resistance and tend to be ineffective. Malaysian citizens began to demand the Malaysian government to change the pattern of political information management. In addition, the mass media alone is expected to play a more significant role as an intermediary agent in supporting the process of transparency and accountability of government policy. This article shows that the openness of public information is a prerequisite for political democracy in Malaysia to help the government minimize the mis-management of governance policies, especially in finance and resource management.

  19. Repositioning Strategy for Malaysian Companies Internationalization

    Directory of Open Access Journals (Sweden)

    Ismi Rajiani

    2013-04-01

    Full Text Available The rise of the emerging-market countries offers both developing and developed countries a unique opportunity to gain the benefits of a truly international economy. Consequently, it is imper- ative to advance our knowledge of emerging-market countries MNC emergence and competitive- ness including Malaysian firms on how will they position their products strategically. Based on the framework of Porter’s Generic Strategy, this paper is composed of price/ volume segments and im- pacts on product strategy theory. The aim is to identify crucial triggering cues and focus areas for Malaysian companies and measure what role these play in different segments. This study argues that some Malaysian companies will reposition themselves strategically when internationalizing and that they will focus on other factors or triggering cues when doing so not merely adapting the prevalent price leadership strategy.

  20. Malaysian Affordability Housing Policies Revisited

    Directory of Open Access Journals (Sweden)

    Samad Diwa

    2016-01-01

    Full Text Available Housing has always been a significant aspiration of family expression and distinctly priciest investment by household. It plays a momentous role in the country’s economy and so central to the societal well-being that is emplaced in the United Nation Universal declaration of Human rights. Yet in developed and developing world alike, cities struggle to provide decent housing for lower and middle income population. The provision of affordable housing is a major policy concern around the world with Malaysia being no exception; rising income hardly keep pace with price hike of housing unit and housing interventions has majorly concentrated on demand side leading to a non-responsive supply sector. Therefore, this paper highlights affordable housing issues pertaining Malaysia. It formulates Malaysian Map of affordability and conducts an evaluation of global housing schemes to better identify policy priorities for Malaysia. It’s significant to harmonize supply and demand side factors in the housing market to ensure that housing supply fits the needs of citizens based on the location, price and target group. In case of Malaysia supply oriented initiative are of urgency in short and medium run. This must be supported by long term demand side schemes in parallel. Convergence of these two factors is essential for a balanced equilibrium and obtaining affordability.

  1. Prediction of Malaysian monthly GDP

    Science.gov (United States)

    Hin, Pooi Ah; Ching, Soo Huei; Yeing, Pan Wei

    2015-12-01

    The paper attempts to use a method based on multivariate power-normal distribution to predict the Malaysian Gross Domestic Product next month. Letting r(t) be the vector consisting of the month-t values on m selected macroeconomic variables, and GDP, we model the month-(t+1) GDP to be dependent on the present and l-1 past values r(t), r(t-1),…,r(t-l+1) via a conditional distribution which is derived from a [(m+1)l+1]-dimensional power-normal distribution. The 100(α/2)% and 100(1-α/2)% points of the conditional distribution may be used to form an out-of sample prediction interval. This interval together with the mean of the conditional distribution may be used to predict the month-(t+1) GDP. The mean absolute percentage error (MAPE), estimated coverage probability and average length of the prediction interval are used as the criterions for selecting the suitable lag value l-1 and the subset from a pool of 17 macroeconomic variables. It is found that the relatively better models would be those of which 2 ≤ l ≤ 3, and involving one or two of the macroeconomic variables given by Market Indicative Yield, Oil Prices, Exchange Rate and Import Trade.

  2. Leasing physician office space.

    Science.gov (United States)

    Murray, Charles

    2009-01-01

    When leasing office space, physicians should determine the effective lease rate (ELR) for each building they are considering before making a selection. The ELR is based on a number of factors, including building quality, building location, basic form of lease agreement, rent escalators and add-on factors in the lease, tenant improvement allowance, method of square footage measurement, quality of building management, and other variables. The ELR enables prospective physician tenants to accurately compare lease rates being quoted by building owners and to make leasing decisions based on objective criteria.

  3. Sustainability in the Malaysian palm oil industry

    OpenAIRE

    Choong, CG; McKay, A

    2014-01-01

    With a rapidly growing world population, the demand for palm oil is increasing. In 2010, palm oil accounted for 36.5% of the world's vegetable oil production and it is projected to be the leading vegetable oil in the world by 2016. As the Malaysian palm oil industry is committed to delivering sustainable palm oil products to meet customer demand, this research was to enable identification and prioritisation of areas for improvement. As an example, the Roadmap of Malaysian Palm Oil Industry 20...

  4. Potential Of Light Pipes System In Malaysian Climate

    Science.gov (United States)

    Abd Kadir, Aslila; Hakim Ismail, Lokman; Kasim, Narimah; Kaamin, Masiri

    2016-11-01

    Light-pipes system are simple structures that allow the transmission of daylight from the outside to the inside of a room. It is a practical application in many buildings where daylight cannot reach due to building design and limited facade to placing windows. Since roof is the element directly exposed to the sunlight, light pipes system could be introduced. This paper examines the illumination levels obtained using light pipes system under Malaysia climate conditions. A light-pipe system that was installed in a test room located in Batu Pahat. Indoor illuminance distributions and concurrent outdoor illuminance were monitored at a 30 minutes interval for 5 days. The results indicated that the amount of daylight penetrated into the building are varied with less than 150lux in the early morning and late evening, and maximum at over 350lux in the noon and early afternoon. The average internal illuminance levels offer by light pipe system met the MS 1525:2007 recommendation for application in Malaysian buildings. These findings indicated that the light pipe system has a potential as a tool for introducing daylight indoors in Malaysia.

  5. Investigation and analysis on energy consumption of several government agency office buildings in Fuzhou%福州市区若干机关办公建筑能耗现状调查与分析

    Institute of Scientific and Technical Information of China (English)

    林卫东

    2012-01-01

    文章通过对福州市区10个机关办公建筑的建筑能耗调查与统计分析,并对典型办公综合楼进行能耗拆分和计算,得出各分项能耗的能耗构成比例和大致能耗量。%In this paper,the energy consumption of 10 government agency office buildings in Fuzhou was investigated and summarized,and the typical office building energy consumption was split and calculated,based on the analysis,energy consumption ratio and roughly consumption of energy consumption of subentry was obtained.

  6. Malaysian water sector reform : policy and performance

    NARCIS (Netherlands)

    Kim, C.T.

    2012-01-01

    One of the measures that can help developing countries in meeting Target 10 of the Millennium  Development Goals – halving the number of people without access to water and adequate sanitation  by 2015 – is through a water sector reform. In this research the Malaysian water sect

  7. Assessing conservation status of Peninsular Malaysian Begonias

    NARCIS (Netherlands)

    Chua, L.S.L.; Kiew, R.; Chan, Y.M.

    2009-01-01

    Following the revision of Peninsular Malaysian Begonia, a project that involved extensive fieldwork, we now have sufficient data to assess their conservation status. Out of 54 taxa, 48 are endemic to Peninsular Malaysia. No fewer than 30 taxa are known from fewer than five localities; 24 taxa are Cr

  8. Ethical Issues in the Malaysian Education System

    Science.gov (United States)

    Kenayathulla, Husaina Banu

    2015-01-01

    Malaysia is a multi-ethnic country in which the government gives preferential treatment in education, employment, and ownership to its majority ethnic group: Bumiputera. However, affirmative action policies in the current Malaysian context should work according to John Rawls' Theory of Justice by being based on income rather than ethnicity.…

  9. Drivers for Cleaner Production in Malaysian Industry

    DEFF Research Database (Denmark)

    Wangel, Arne

    2003-01-01

    This working paper tries to piece together information on regulatory initiatives promoting cleaner production (CP) in Malaysian industry, as well as points of discussion on environmental performance in the sector. It draws upon initial data collection by the team of the research project ‘A Study ...

  10. Malaysian water sector reform : policy and performance

    NARCIS (Netherlands)

    Kim, C.T.

    2012-01-01

    One of the measures that can help developing countries in meeting Target 10 of the Millennium  Development Goals – halving the number of people without access to water and adequate sanitation  by 2015 – is through a water sector reform. In this research the Malaysian water

  11. Transporting GOLDEN RICE to Malaysian Classrooms

    Science.gov (United States)

    Naidu, Shashi

    2007-01-01

    This article evaluates the effectiveness of using a simulation in an English for Academic Purposes (EAP) class at a university in the United States and discusses the integration of simulations into the Malaysian curriculum. A new approach is needed in Malaysia wherein language learners are given maximum exposure to the language. The article…

  12. Ethical Issues in the Malaysian Education System

    Science.gov (United States)

    Kenayathulla, Husaina Banu

    2015-01-01

    Malaysia is a multi-ethnic country in which the government gives preferential treatment in education, employment, and ownership to its majority ethnic group: Bumiputera. However, affirmative action policies in the current Malaysian context should work according to John Rawls' Theory of Justice by being based on income rather than ethnicity.…

  13. Malaysian water sector reform : policy and performance

    NARCIS (Netherlands)

    Kim, C.T.

    2012-01-01

    One of the measures that can help developing countries in meeting Target 10 of the Millennium  Development Goals – halving the number of people without access to water and adequate sanitation  by 2015 – is through a water sector reform. In this research the Malaysian water sect

  14. Entrepreneurship Education Programs in Malaysian Polytechnics

    Science.gov (United States)

    Othman, Norasmah; Nasrudin, Norfadhilah

    2016-01-01

    Purpose: The purpose of this paper is to evaluate students' views on the on-the-campus entrepreneurship programs in Malaysian polytechnics. Participation in the entrepreneurship programs is able to stimulate an interest in entrepreneurship, and improve the knowledge, skills, and entrepreneurial experience of its students.…

  15. Eclectic Model in the Malaysian Education System

    Science.gov (United States)

    Othman, Nooraini; Mohamad, Khairul Azmi; Ilmuwan, Yayasan

    2011-01-01

    The present work aims at analysing the adoption of eclectic model in the Malaysian education system. The analysis is specifically looked from the angle of Islam and the Muslims. Malaysia has a long history of education system developments, from pre to post independence of the country. From what was initially traditional, modernity later came to…

  16. Phrasal Verbs in Malaysian ESL Textbooks

    Science.gov (United States)

    Zarifi, Abdolvahed; Mukundan, Jayakaran

    2012-01-01

    It is often claimed that ELT textbook materials are mostly unwittingly intuitively- rather than empirically-based and that this bookish form of language is far from reflecting the real language use. The present study, by adopting a corpus-based approach, tends to shed light on the extent of agreement between the Malaysian ESL textbooks and the…

  17. Malaysian Children's Attitudes towards Learning Music

    Science.gov (United States)

    Ghazali, Ghaziah Mohd.; McPherson, Gary E.

    2009-01-01

    A sample of 1060 Malaysian children were surveyed in order to examine differences in their motivation to study music in school and to learn a musical instrument outside of school. Adopting the expectancy-value motivation theory, the children were asked questions concerning their perception of music as being important, useful, interesting,…

  18. Research on Two Types of Buffer Zone Impact on Surrounding Office Space Environment in Winter in Cold Climate Zone-a Fieldwork in Architectural Design Institute Building of Tsinghua University, Beijing

    Institute of Scientific and Technical Information of China (English)

    YeHao Song; JunJie Li; Ning Zhu; JiaLiang Wang; ShiMeng Hao

    2014-01-01

    Building buffer zone space is not only one of essential approaches for better mental quality of interior building space, but also an important factor that may influence interior thermal comfort and energy consumption. This study aims to analyze regulative advantages of buffer zone to the surrounding functional spaces. Based on a fieldwork test in a typical office building in cold climate zone in Beijing, China, the monitor data show interior physical performance in the Winter. The research selects two types of different buffer zones in the same building. One is a south⁃faced greenhouse which has large dimension with plenty of vegetation, and the other is a simple atrium in the middle of five floor building with mount of skylights. The factors and their influence to surrounding functional spaces and the whole building are found out from the comparisons of collected data by floor to floor monitor test on both buffer zones at the same time. The comparisons of two types of buffer zones conclude that the greenhouse is more effective to air quality regulation but not so clearly well⁃performed to thermal buffering as expected due to the dominate active central heating in the Winter. This fieldwork test results for building performance can be helpful for both architects and engineers in the early phase of sustainable design.

  19. Energy Consumption Characteristics Analysis of Non-governmental Office Building in Shenzhen%深圳市非政府办公建筑能耗特性分析

    Institute of Scientific and Technical Information of China (English)

    伍品; 杨英霞; 王智超

    2015-01-01

    Based on the energy audit data of 27 non-governmental office buildings in Shenzhen, this paper counted and compared the respects of basic information, energy system form, and total energy consumption and breakdown energy consumption of air conditioning, analyzed energy characteristics, and focused on the research of air conditioning energy consumption characteristics of large non-government office buildings. The results showed that energy consumption of non-governmental office building was high in Shenzhen; Energy consumption of air conditioning accounted for a large proportion; Air conditioning cooling station was important of energy-saving potential; And chilled water pump and cooling water pump of air-conditioning was a direction of energy saving alteration for non-governmental office buildings in Shenzhen.%基于深圳市27栋非政府办公建筑的能源审计数据,从建筑样本基本信息、用能系统形式、总能耗及空调分项能耗等方面进行统计与比较,分析了深圳市非政府办公建筑的能耗特性,并对深圳市大型非政府办公建筑的空调能耗特性进行了重点研究。结果表明,深圳市非政府办公建筑能耗较高,空调能耗占较大比例,空调冷站是节能潜力的重点,空调冷冻及冷却水泵是深圳市非政府办公建筑节能改造的一个方向。

  20. Evaluation Research on the Influence Factors of the Rents of Business Office Building Based on Analytic Hierarchy Process%基于AHP法的商务写字楼租金影响因素评价研究

    Institute of Scientific and Technical Information of China (English)

    叶剑锋

    2015-01-01

    本文主要研究了商务写字楼租金影响因素,并应用AHP法确定了各项最终指标,然后依据指标权重从写字楼资产运营的角度提出如何提升存量写字楼的租金的资产运营建议。%This paper mainly studies the influence factors of the rents of business office building and determines the final indexes by analytic hierarchy process. Then according to the index weight, it puts forward the suggestions of assets operation to improve the office rents stock from the perspective of office assets operation.

  1. Craniofacial anthropometric norms of Malaysian Indians

    Directory of Open Access Journals (Sweden)

    Ngeow W

    2009-01-01

    Full Text Available Objective: This study was done to establish the craniofacial anthropometric norms of the young adult (18- 25 years Malaysian Indian. Materials and Methods: The study group consisted of convenient samples of 100 healthy volunteers, with equal number of female and male subjects who had no history of mixed racial-parentage. Twenty-two linear measurements were taken twice from 28 landmarks over six craniofacial regions. The methodology and evaluation of indices of the craniofacial region was adapted from Hajnis et al. Results: The minimum measurements are always contributed by the female Indian except for the nose height (n-sn, (left eye fissure length (ex-en, upper vermillion height (ls-sto, and lower vermillion height (sto-li. There is a gender difference in all the measurements except the (left eye fissure height (independent t-test; P < 0.05. The Malaysian Indians exhibit some North American White Caucasian (NAWC features in all regions. The cephalic index indicates a brachycephalic or relatively short wide head with a tendency towards mesocephaly. From the low nasal index, the Malaysian Indian female have a nose that is narrow or leptorrhin similar to the NAWCs. The lower value of the upper lip height to mouth width index in the Indian female indicates a relatively shorter upper lip height compared to the mouth width, also similar to the NAWC. Conclusion: This study establishes the craniofacial anthropometric norms of the Malaysian Indian over 22 parameters. Male in general has a significantly higher measurement than female. The Malaysian Indians do exhibit some NAWC features.

  2. Sustainable Campus: Indoor Environmental Quality (IEQ Performance Measurement for Malaysian Public Universities

    Directory of Open Access Journals (Sweden)

    Wan Zahari Wan Yusoff

    2014-10-01

    Full Text Available Indoor Environmental Quality (IEQ for academic buildings is one of the key characteristics of a sustainable campus. The low conditions of IEQ performance can contribute to the sick building syndrome and cause discomfort to the building users.Furthermore, good performance of IEQ can contribute to a comfort and conducive learning and working environment. The purpose of this paper is to discuss on the IEQperformance measurement of academic buildings for public universities in Malaysia. This research involved scientific measurement of academic buildings for public universities inMalaysia. The performance measurement focuses on the six key elements of IEQ; thermal comfort, humidity, noise comfort, air movement, lighting and thickness of CO2. Theresults were compared to the Malaysian Standard (MS 1525:2007 and UNESCO guideline. The findings showed that most universities are in the standard set, while someuniversities under the standards set and still in need of improvement. This study is useful for facilities managers in public universities in order to improve the IEQ on academicbuildings in achieving sustainable campus.Keywords: Sustainable development, Sustainable environment, Sustainable campus, Indoor Environmental Quality, Malaysian public universities.

  3. 深圳地区办公建筑服务水平与空调能耗的相关性分析%Correlation Analysis of Service Level and Air Conditioning Energy Consumption of Office Buildings-Taking Office Buildings in Shenzhen for Example

    Institute of Scientific and Technical Information of China (English)

    吴银萍; 付祥钊; 孙冬梅; 余能辉

    2012-01-01

    For the similar buildings,the differences in level of construction services will lead to differences in the indoor environmental control parameters and the distribution of heat sources,thus affecting the energy consumption of air conditioning.This paper briefly describes the content of the level of construction services,and then without taking into account climate and building form parameters on the impact of energy consumption,it sets different service levels and technical level for an office building in Shenzhen and analyzes the association between construction services and air-conditioning energy consumption by simulations.Conclusion is that not only from a technical level,choosing the appropriate level of construction services can also effectively reduce building air conditioning load requirements.On this basis,significances of service-related factors on the impact of energy consumption are analyzed,which providing a reference for reasonable setting of level of construction services.%对于同类建筑,建筑服务水平的差异会导致室内环境控制参数及热源分布的差异,从而影响建筑空调能耗。本文首先对建筑服务水平的内涵进行了简要阐述,然后在不考虑气候及建筑体形参数对能耗影响的条件下,运用DeST-c软件对深圳地区某办公建筑设定不同的服务水平和技术水平进行对比分析,得出建筑服务水平与空调能耗的相关性,进而指出不单从技术水平,选择恰当的服务水平可有效降低空调系统负荷需求。最后,对各服务水平相关因素对能耗影响的显著性进行了分析,为合理的服务水平设置提供参考依据。

  4. Formation process of Malaysian modern architecture under influence of nationalism

    OpenAIRE

    宇高, 雄志; 山崎, 大智

    2001-01-01

    This paper examines the Formation Process of Malaysian Modern Architecture under Influence of Nationalism,through the process of independence of Malaysia. The national style as "Malaysian national architecture" which hasengaged on background of political environment under the post colonial situation. Malaysian urban design is alsodetermined under the balance of both of ethnic culture and the national culture. In Malaysia, they decided to choosethe Malay ethnic culture as the national culture....

  5. Association of airborne moisture-indicating microorganisms withbuilding-related symptoms and water damage in 100 U.S. office buildings:Analyses of the U.S. EPA BASE data

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Lei, Quanhong; Cozen, Myrna O.; Shendell, DerekG.; Macher, Janet M.; Tsai, Feng C.

    2003-10-01

    Metrics of culturable airborne microorganisms for either total organisms or suspected harmful subgroups have generally not been associated with symptoms among building occupants. However, the visible presence of moisture damage or mold in residences and other buildings has consistently been associated with respiratory symptoms and other health effects. This relationship is presumably caused by adverse but uncharacterized exposures to moisture-related microbiological growth. In order to assess this hypothesis, we studied relationships in U.S. office buildings between the prevalence of respiratory and irritant symptoms, the concentrations of airborne microorganisms that require moist surfaces on which to grow, and the presence of visible water damage. For these analyses we used data on buildings, indoor environments, and occupants collected from a representative sample of 100 U.S. office buildings in the U.S. Environmental Protection Agency's Building Assessment Survey and Evaluation (EPA BASE) study. We created 19 alternate metrics, using scales ranging from 3-10 units, that summarized the concentrations of airborne moisture-indicating microorganisms (AMIMOs) as indicators of moisture in buildings. Two were constructed to resemble a metric previously reported to be associated with lung function changes in building occupants; the others were based on another metric from the same group of Finnish researchers, concentration cutpoints from other studies, and professional judgment. We assessed three types of associations: between AMIMO metrics and symptoms in office workers, between evidence of water damage and symptoms, and between water damage and AMIMO metrics. We estimated (as odds ratios (ORs) with 95% confidence intervals) the unadjusted and adjusted associations between the 19 metrics and two types of weekly, work-related symptoms--lower respiratory and mucous membrane--using logistic regression models. Analyses used the original AMIMO metrics and were

  6. 高层办公空间的公共空间设计与探讨%Design and Discussion on Public Space of High-rise Office Buildings

    Institute of Scientific and Technical Information of China (English)

    刘璐

    2015-01-01

    With the development of office space, different types of office space emerge rapidly. Due to the efficiency of urban land use at present, the high-rise office space is still the mainstream. With the limitations of high-rise buildings, to create positive space in the high-rise building turns to be an important issue to improve work efficiency and humanization. Based on some cases, the creation of public space mode with application effects and the change of human activity mode are elaborated, and the feasible design principles for high-rise office buildings are also explored.%随着办公空间的发展,不同类型的办公空间层出不穷,但现阶段由于城市土地利用效率问题,办公空间仍主要以高层为主,而高层建筑又有其局限性。如何在高层建筑中创造公共空间是提高办公效率和发展人性化办公的重要课题。该文通过案例阐述高层建筑中创造公共空间的模式与应用效果及人的行为模式的改变,从而摸索出高层办公公共空间设计与绿色设计的可行原则。

  7. Temporal evolution of radon in various offices of a public building in Caceres; Evolucion de temporal de radon en vairas dependencias de un edificio publico en Ceceres

    Energy Technology Data Exchange (ETDEWEB)

    Miro, C.; Pacheco, C.

    2011-07-01

    It has made a study of the temporal evolution of Rn-222 in a building used as a workplace. The building was built in the nineteenth century and restored in the second half of the twentieth century. The measurements were performed simultaneously in three units located in a basement, in the first and second floor respectively. It also includes a description of the architectural features of the building, construction materials used and placement of them. (Author)

  8. Factors influencing the intention of Malaysian working adults towards lifelong learning

    Directory of Open Access Journals (Sweden)

    Abdullah Sarwar

    2016-06-01

    Full Text Available Lifelong learning is an option to fulfil societal needs in order to create a dynamic society. The rising in participation in lifelong learning programmes contributed due to the pressure of globalization and technologies in Malaysia’s changing demography. Therefore, this study aimed at identifying the factors that influence the intention of the Malaysian working adults towards lifelong learning and to develop marketing strategies for Malaysian education providers. The foundation of this study is based on the Theory of Planned Behaviour. However, two additional variables were included as the extension to the current model which is trust and perceived usefulness. This research was designed as a cross-sectional field survey, where questionnaire were used for data collection. The target population for this study were the Malaysian working adults who are working in different organizations within the Klang Valley area. The sample size for this research is 210. The hypothesized path analysis was conducted through the Structural Equation Modelling (SEM. All the hypotheses were accepted due to the fact that they were statistically significant. The study provides the management of lifelong education centre an insight to develop effective marketing strategies to satisfy that value of potential customers. The findings will also be beneficial to government agencies, policy maker and higher education practitioner by creating insight into adult learner perception and building intentional behaviour to purchase the product. Finally, limitations were discussed and future study direction is proposed.

  9. 76 FR 28789 - Draft Alert Entitled “Preventing Occupational Respiratory Disease From Dampness in Office...

    Science.gov (United States)

    2011-05-18

    ... Occupational Respiratory Disease from Dampness in Office Buildings, Schools, and other Nonindustrial Buildings... HUMAN SERVICES Centers for Disease Control and Prevention Draft Alert Entitled ``Preventing Occupational Respiratory Disease From Dampness in Office Buildings, Schools, and Other Nonindustrial Buildings''...

  10. Better Buildings Challenge Overview

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-06-01

    The Better Buildings Challenge is a national leadership initiative calling on corporate chief executive officers, university presidents, and state and local leaders to make a significant commitment to building energy efficiency.

  11. Radiological emergency: Malaysian preparedness and response.

    Science.gov (United States)

    Yusof, Mohd Abd Wahab; Ali, Hamrah Mohd

    2011-07-01

    Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources that will be needed. In Malaysia, planning, preparation for and response to radiological emergencies involve many parties. In the event of a radiological emergency and if it is considered a disaster, the National Security Council, the Atomic Energy Licensing Board and the Malaysian Nuclear Agency (Nuclear Malaysia) will work together with other federal agencies, state and local governments, first responders and international organisations to monitor the situation, contain the release, and clean up the contaminated site. Throughout the response, these agencies use their protective action guidelines. This paper discusses Malaysian preparedness for, and response to, any potential radiological emergency.

  12. KfW Westarkade Frankfurt am Main. Energy-efficient office building; KfW Westarkade Frankfurt am Main. Energieeffizientes Buerohochhaus

    Energy Technology Data Exchange (ETDEWEB)

    Holl, Christian

    2010-07-01

    Westarkade, the new building of the KfW Bankengruppe, is a ''medium-high'' building, rising only about 56 metres. But this is the kind of building height that is commonly found in the scope of urban redevelopment and renewal in many German conurbations. The Westarkade can therefore function beautifully as a model precisely because it is of a fairly typical size. And the new building, planned and realised with the greatest attention and the highest architectural standards, does indeed boast energy consumption figures that lie far below those of comparable buildings. The outstanding aspect of this skyscraper is not sheer height but the way an architectural problem has been solved in full awareness of our responsibility for the future of the city. Client, architects and energy planners have trodden new paths to realise an exemplary project against which other skyscrapers in tis size class will have to be measured. (orig./AKB)

  13. Drivers for Malaysian SMEs to Go Green

    OpenAIRE

    M. Krishna Moorthy; Peter a/l Yacob; Mahendra Kumar a/l Chelliah; Lawrence Arokiasamy

    2012-01-01

    Small and Medium Enterprises (SMEs) around the world have little knowledge about environmental management and do not understand the concept of environmental management. The concept of green is still very new to Malaysian SME owners/managers, although many green conferences, seminars and campaigns have been carried out for quite some time. The concept for green process and products in Malaysia is at the infancy stage. The drivers of environmental behavior in SMEs are relatively under-researche...

  14. Religiosity, Ethical Judgments and Malaysian Muslim Students

    OpenAIRE

    Rusnah Muhamad

    2014-01-01

    Culture is often cited as one of the powerful determinants in shaping the personality and behaviour of individuals. Religion, being an important element of culture, is seen as playing an important role in determining how people behave in certain situations. Various authors have suggested religion as an important dimension in Malaysian ethical behaviour studies especially for the Malays. Yet this construct is generally ignored or incorporated into other constructs. This study investigates the ...

  15. LAUGHING AT OURSELVES: REFLECTING MALAYSIAN ETHNIC DISPARITIES

    OpenAIRE

    SWAGATA SINHA ROY; KAVITHA SUBARAMANIAM

    2014-01-01

    Malaysia’s various ethnic groups make interesting study both sociologically and culturally. With such a heady mix of cultural elements to explore, it is often natural that the many groups stumble upon ‘rare gems’ that reflect their ‘Malaysianess’. Have Malaysians really ever appreciated the many and varied aspects of culture that they are seemingly suddenly thrown into? Do we embrace these happily or are we constantly rejecting them? Fortunately, through the medium of film, we are, from time ...

  16. The question of questions in Malaysian English

    OpenAIRE

    Asniah Alias; Radina Mohamad Deli

    2013-01-01

    This paper examined the forms that interrogatives and tag questions can take when used by young Malaysian speakers of English language in oral communication. It offers a description of the features for both question forms as produced by the respondents compared to those of Singapore English (SE) and Standard British English (SBE). The influence of domains and the issue of mother tongue interference in relation to the subjects’ usage of such features will also be investigated. Data were obtain...

  17. Do time-averaged, whole-building, effective volatile organic compound (VOC) emissions depend on the air exchange rate? A statistical analysis of trends for 46 VOCs in U.S. offices.

    Science.gov (United States)

    Rackes, A; Waring, M S

    2016-08-01

    We used existing data to develop distributions of time-averaged air exchange rates (AER), whole-building 'effective' emission rates of volatile organic compounds (VOC), and other variables for use in Monte Carlo analyses of U.S. offices. With these, we explored whether long-term VOC emission rates were related to the AER over the sector, as has been observed in the short term for some VOCs in single buildings. We fit and compared two statistical models to the data. In the independent emissions model (IEM), emissions were unaffected by other variables, while in the dependent emissions model (DEM), emissions responded to the AER via coupling through a conceptual boundary layer between the air and a lumped emission source. For 20 of 46 VOCs, the DEM was preferable to the IEM and emission rates, though variable, were higher in buildings with higher AERs. Most oxygenated VOCs and some alkanes were well fit by the DEM, while nearly all aromatics and halocarbons were independent. Trends by vapor pressure suggested multiple mechanisms could be involved. The factors of temperature, relative humidity, and building age were almost never associated with effective emission rates. Our findings suggest that effective emissions in real commercial buildings will be difficult to predict from deterministic experiments or models.

  18. Factors Affecting Hypertension among the Malaysian Elderly

    Directory of Open Access Journals (Sweden)

    Sima Ataollahi Eshkoor

    2016-03-01

    Full Text Available Hypertension is a common chronic disease in the elderly. This study aimed to determine the effects of age, ethnicity, gender, education, marital status, nutritional parameters, and blood elements on the risk of high blood pressure in the Malaysian elderly. This research was conducted on a group of 2322 non-institutionalized Malaysian elderly. The hierarchy binary logistic regression analysis was applied to estimate the risk of hypertension in respondents. Approximately, 45.61% of subjects had hypertension. The findings indicated that the female gender (Odds ratio (OR = 1.54, an increase in body weight (OR = 1.61, and an increase in the blood levels of albumin (OR = 1.51, glucose (OR = 1.92, and triglycerides (OR = 1.27 significantly increased the risk of hypertension in subjects (p < 0.05. Conversely, an increase in both dietary carbohydrates (OR = 0.74, and blood cholesterol level (OR = 0.42 significantly reduced the risk of hypertension in samples (p < 0.05. Furthermore, the results showed that ethnicity was a non-relevant factor to increase the risk of hypertension in subjects. It was concluded that female gender, an increase in body weight, and an increase in the blood levels of glucose, triglycerides, and albumin enhanced the risk of high blood pressure in the Malaysian elderly. In addition, an increase in both dietary carbohydrates and blood cholesterol level decreased hypertension in subjects.

  19. LAUGHING AT OURSELVES: REFLECTING MALAYSIAN ETHNIC DISPARITIES

    Directory of Open Access Journals (Sweden)

    SWAGATA SINHA ROY

    2014-05-01

    Full Text Available Malaysia’s various ethnic groups make interesting study both sociologically and culturally. With such a heady mix of cultural elements to explore, it is often natural that the many groups stumble upon ‘rare gems’ that reflect their ‘Malaysianess’. Have Malaysians really ever appreciated the many and varied aspects of culture that they are seemingly suddenly thrown into? Do we embrace these happily or are we constantly rejecting them? Fortunately, through the medium of film, we are, from time to time, allowed to reflect on our obvious similarities and even more apparent disparities. In this paper, we explore the culture and perceptions of people from the major ethnic groups that are the human base of this very country. When was it we have last laughed at ourselves … heartily? Nasi Lemak 2.0 provides an interesting, if not disturbing insight into the workings of the Malaysian ‘mind’. Nasi Lemak 2.0 was released on 8th September 2011 and impacted a whole generation of Malaysians. The characters have been well chosen and have done a wonderful job of being representations of the various communities in this nation. Ethnocentrism is a reality and often rears its head, ‘ugly’ or otherwise in several situations. Are we able to grapple with the levels of ethnocentrism that we encounter? These are some of the issues that will trigger much debate and discussion among ourselves and perhaps also reflect our cores.

  20. Are Malaysian Children Achieving Dietary Guideline Recommendations?

    Science.gov (United States)

    Koo, Hui Chin; Poh, Bee Koon; Lee, Shoo Thien; Chong, Kar Hau; Bragt, Marjolijn C E; Abd Talib, Ruzita

    2016-07-01

    A large body of epidemiological data has demonstrated that diet quality follows a sociodemographic gradient. Little is known, however, about food group intake patterns among Malaysian children. This study aimed to assess consumption pattern of 7 food groups, including cereals/grains, legumes, fruits, vegetables, fish, meat/poultry, and milk/dairy products, among children 7 to 12 years of age. A total of 1773 children who participated in SEANUTS Malaysia and who completed the Food Frequency Questionnaire were included in this study. A greater proportion of children aged 10 to 12 years have an inadequate intake of cereals/grains, meat/poultry, legumes, and milk/dairy products compared with children 7 to 9 years old. With the exception of meat/poultry, food consumption of Malaysian children did not meet Malaysian Dietary Guidelines recommendations for the other 6 food groups, irrespective of sociodemographic backgrounds. Efforts are needed to promote healthy and balanced dietary habits, particularly for foods that fall short of recommended intake level.

  1. Post Offices, Local Building - buiding footprint is included in the local building layer, Published in 2008, 1:2400 (1in=200ft) scale, Effingham County Board Of Commissioners.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Post Offices dataset, published at 1:2400 (1in=200ft) scale, was produced all or in part from Orthoimagery information as of 2008. It is described as 'Local...

  2. Young Adult Literature in the Malaysian Secondary School

    Science.gov (United States)

    Govindarajoo, Mallika V.; Mukundan, Jayakaran

    2013-01-01

    This article presents the results of a study on the experience of the Malaysian secondary school student with Young Adult Literature in the English language classroom. The study aimed to determine the extent to which the Malaysian secondary school student identified with the young adult protagonists and issues in the novels which have been…

  3. Lexical Borrowing from Chinese Languages in Malaysian English

    Science.gov (United States)

    Imm, Tan Siew

    2009-01-01

    This paper explores how contact between English and Chinese has resulted in the incorporation of Chinese borrowings into the lexicon of Malaysian English (ME). Using a corpus-based approach, this study analyses a comprehensive range of borrowed features extracted from the Malaysian English Newspaper Corpus (MEN Corpus). Based on the contexts of…

  4. Language Learning Motivation among Malaysian Pre-University Students

    Science.gov (United States)

    Muftah, Muneera; Rafik-Galea, Shameem

    2013-01-01

    The study describes and examines Malaysian pre-university students' integrative and instrumental motivation toward learning English language. In this study, 182 non-English major students in one of the Malaysian public universities are selected to fill out a questionnaire reflecting their attitudes and motivation towards learning English. The…

  5. Malaysian English: An Instrumental Analysis of Vowel Contrasts

    Science.gov (United States)

    Pillai, Stefanie; Don, Zuraidah Mohd.; Knowles, Gerald; Tang, Jennifer

    2010-01-01

    This paper makes an instrumental analysis of English vowel monophthongs produced by 47 female Malaysian speakers. The focus is on the distribution of Malaysian English vowels in the vowel space, and the extent to which there is phonetic contrast between traditionally paired vowels. The results indicate that, like neighbouring varieties of English,…

  6. National space legislation : future perspectives for Malaysian Space Law

    NARCIS (Netherlands)

    Saari, Che Zuhaida Binti

    2014-01-01

    This research studies the future perspectives for Malaysian space law. It aims at demonstrating the development of Malaysian outer space activities inclusive of her status with respect to United Nations space conventions and her membership of international and regional space-related organizations. O

  7. Strategic Information Systems Planning in Malaysian Public Universities

    Science.gov (United States)

    Ismail, Noor Azizi; Raja Mohd Ali, Raja Haslinda; Mat Saat, Rafeah; Hsbollah, Hafizah Mohamad

    2007-01-01

    Purpose: The paper's purpose is to investigate the current status, problems and benefits of strategic information systems planning implementation in Malaysian public universities. Design/methodology/approach: The study uses dual but mutually supportive strands of investigation, i.e. a questionnaire survey and interviews. Findings: Malaysian public…

  8. Malaysian English: An Instrumental Analysis of Vowel Contrasts

    Science.gov (United States)

    Pillai, Stefanie; Don, Zuraidah Mohd.; Knowles, Gerald; Tang, Jennifer

    2010-01-01

    This paper makes an instrumental analysis of English vowel monophthongs produced by 47 female Malaysian speakers. The focus is on the distribution of Malaysian English vowels in the vowel space, and the extent to which there is phonetic contrast between traditionally paired vowels. The results indicate that, like neighbouring varieties of English,…

  9. A Pilot CAI Scheme for the Malaysian Secondary Education System.

    Science.gov (United States)

    Rao, A. Kanakaratnam; Rao, G. S.

    1982-01-01

    A multi-phase computer aided instruction (CAI) scheme for Malaysian Secondary Schools and Matriculation Centres attached to local universities is presented as an aid for improving instruction and for solving some problems presently faced by the Malaysian Secondary Education System. Some approaches for successful implementation of a CAI scheme are…

  10. Self-Access Language Learning for Malaysian University Students

    Science.gov (United States)

    Tse, Andrew Yau Hau

    2012-01-01

    Just a few Malaysian universities offer self-access language learning activities to students. The objective of this study is to investigate if self-access learning can promote self-directed or autonomous learning in a public Malaysian technical university. Data collection is by means of interviewing the Director, lecturers, and students in a…

  11. The Quest for Strategic Malaysian Quality National Primary School Leaders

    Science.gov (United States)

    Ali, Hairuddin Mohd

    2012-01-01

    Purpose: The purpose of this paper is to investigate the nine-point strategic leadership characteristics of Malaysian Quality National Primary School Leaders (QNPSL) and to indicate the implications of these findings for the current educational management and leadership practices in their quest for Malaysian quality education.…

  12. A Career Success Model for Academics at Malaysian Research Universities

    Science.gov (United States)

    Abu Said, Al-Mansor; Mohd Rasdi, Roziah; Abu Samah, Bahaman; Silong, Abu Daud; Sulaiman, Suzaimah

    2015-01-01

    Purpose: The purpose of this paper is to develop a career success model for academics at the Malaysian research universities. Design/methodology/approach: Self-administered and online surveys were used for data collection among 325 academics from Malaysian research universities. Findings: Based on the analysis of structural equation modeling, the…

  13. National space legislation : future perspectives for Malaysian Space Law

    NARCIS (Netherlands)

    Saari, Che Zuhaida Binti

    2014-01-01

    This research studies the future perspectives for Malaysian space law. It aims at demonstrating the development of Malaysian outer space activities inclusive of her status with respect to United Nations space conventions and her membership of international and regional space-related organizations. O

  14. Dates of publication of Malaysian phyto-taxonomical literature

    NARCIS (Netherlands)

    NN,

    1947-01-01

    Under this heading will be found information on the dates of publication of Malaysian botanical works or others of importance to Malaysian phytotaxonomy. Several of these are in the ”Journal of the Society for Bibliography of Natural History” an expensive serial of which 6 parts have appeared betwee

  15. Officer Training

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This dataset shows the time spent by currently active Pittsburgh Police Officers in professional development training. Officers who are no longer employed in the...

  16. 基于天然采光的办公建筑健康光环境研究%Research on Healthy Light Environment of Office Building Based on Natural Lighting

    Institute of Scientific and Technical Information of China (English)

    肖辉; 陈小双; 彭玲; 姚梦

    2015-01-01

    办公室是人们日常生活工作的重要场所,办公室的光环境不仅影响人们的用眼健康,更对其生理、心理产生影响。天然光作为一种绿色能源,在改善办公建筑光环境方面有着不可替代的作用。以营造健康光环境为根本出发点,将矩阵分析与控制理论相结合,提出了天然采光与人工照明联合控制模型。同时为论证模型有效性,本文运用Ecotect、 DIALlux软件对长9m、宽4m、高4m的标准办公空间进行仿真,证明本文所提出的联合控制模型可以很好的控制室内照度,营造舒适健康的室内光环境。%The office building is an important and necessary place for people to work in the daily life.The light environment of the office not only affects the eye health of people, but also has an impact on physiology and psychology.As a kind of green energy, natural light plays an irreplaceable role in improving the light environment of office building.In this paper, a combined control strategy of natural lighting and artificial lighting based on matrix analysis and control theory is proposed to create a healthy light environment which is the fundamental starting point.At the same time, in order to prove the validity of this model, the combined control strategy is used to simulate standard office space whose length is 9m, width is 4m and height is 4m basing on Ecotect and DIALux software.According to the simulation, the combined control strategy proposed in this paper can effectively control the indoor illuminance and create a comfortable and healthy light environment of office building.

  17. 26 April 2012 - Extraordinary and plenipotentiary Ambassador A. Dékány, Permanent Representative of the Republic of Hungary to the United Nations Office and other international organisations at Geneva, signing the guest book with CERN Director-General R. Heuer; visiting the LHC tunnel at Point 5 and CMS experimental area and surface building with Collaboration Deputy Spokespersom T. Camporesi; accompanied by M. Bajko, Technology Department. International Relations Office Adviser R. Voss also present.

    CERN Multimedia

    Jean-claude Gadmer

    2012-01-01

    26 April 2012 - Extraordinary and plenipotentiary Ambassador A. Dékány, Permanent Representative of the Republic of Hungary to the United Nations Office and other international organisations at Geneva, signing the guest book with CERN Director-General R. Heuer; visiting the LHC tunnel at Point 5 and CMS experimental area and surface building with Collaboration Deputy Spokespersom T. Camporesi; accompanied by M. Bajko, Technology Department. International Relations Office Adviser R. Voss also present.

  18. The statistical analysis report of Taiyuan government office building heating energy consumption%太原市国家机关办公建筑采暖能耗统计分析报告

    Institute of Scientific and Technical Information of China (English)

    宋静

    2012-01-01

    从建筑能耗统计工作的背景及意义入手,通过对太原市政府机关办公建筑能耗进行统计,对其能耗统计结果进行了系统的分析,为制定节能对策提供了依据,进而达到节能降耗的目的。%From the background and meaning of building energy consumption statistics, through the statistics to Taiyuan government office build- ing energy consumption, analyzed the energy consumption statistical results, provided basis for formulate energy-saving countermeasures, so as to achieve the purpose of energy saving.

  19. 含内天井的高层SOHO办公建筑人员疏散%Evacuation in a high-rise SOHO office building with multi-story hollow space

    Institute of Scientific and Technical Information of China (English)

    李利敏; 朱国庆; 黄丽丽

    2012-01-01

    为了确定高层SOHO办公建筑火灾时人员的疏散情况,采用场模拟和疏散模拟软件Building EXODUS对某含内天井的高层SOHO办公建筑进行模拟研究,分4个场景分析烟气流动规律以及对人员疏散的影响.模拟结果表明,建筑的内天井不仅给该建筑带来了良好的室内环境,而且能有效地疏导火灾产生的热量和烟气,在建筑喷淋系统失效的情况下,建筑内大部分地区人员能够安全疏散,只有着火层部分地区人员不能安全疏散.因此,火灾时必须确保建筑内灭火系统的可靠有效,以保证人员安全疏散.%In order to determine the evacuation in the high-rise SOHO office huilding , field simulation and evacuation simula - tion software of Building EXODUS were used to study a high-rise SOHO office building with multi-story hollow space. Characteristics of smoke flow were studied to investigate their influences on safety evacuation in four fire scenarios. Simulation results showed that, the multi-story hollow space of a high-rise building not only brings good indoor environment, and effectively evacuates the heat and smoke of the fires. In case of failure of the building sprinkler system, most parts of the building can be safely evacuated from, only some areas of the fire layer can not be safely evacuated from. Therefore, the reliable and effective of sprinkler system in the building is very important to ensure safe evacuation.

  20. Thermal-comfort analysis and simulation for various low-energy cooling-technologies applied to an office building in a subtropical climate

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, Ashfaque Ahmed; Rasul, M.G.; Khan, M.M.K. [College of Engineering and the Built Environment, Faculty of Sciences, Engineering and Health, Central Queensland University, Rockhampton, Qld 4702 (Australia)

    2008-06-15

    Simulation of buildings' thermal-performances is necessary to predict comfort of the occupants in buildings and to identify alternate cooling control-systems for achieving better indoor thermal environments. An analysis and prediction of thermal-comfort using DesignBuilder, based on the state-of-the-art building performance simulation software EnergyPlus, is carried out in an air-conditioned multi-storeyed building in the city of Rockhampton in Central Queensland, Australia. Rockhampton is located in a hot humid-region; therefore, indoor thermal-comfort is strongly affected by the outdoor climate. This study evaluates the actual thermal conditions of the Information Technology Division (ITD) building at Central Queensland University during winter and summer seasons and identifies the thermal comfort level of the occupants using low-energy cooling technologies namely, chilled ceiling (CC), economiser usages and pre-cooling. The Fanger comfort-model, Pierce two-node model and KSU two-node model were used to predict thermal performance of the building. A sophisticated building-analysis tool was integrated with the thermal comfort models for determining appropriate cooling-technologies for the occupants to be thermally comfortable while achieving sufficient energy savings. This study compares the predicted mean-vote (PMV) index on a seven-point thermal-sensation scale, calculated using the effective temperature and relative humidity for those cooling techniques. Simulated results show that systems using a chilled ceiling offer the best thermal comfort for the occupants during summer and winter in subtropical climates. The validity of the simulation results was checked with measured values of temperature and humidity for typical days in both summer and winter. The predicted results show a reasonable agreement with the measured data. (author)

  1. Leadership in the Reform of Malaysian Universities: Analysing the Strategic Role of the Malaysian Qualifications Agency

    Science.gov (United States)

    Bajunid, Ibrahim Ahmad

    2011-01-01

    This paper addresses the contemporary development and reform challenges in tertiary education in Malaysia in both national and global contexts. The critical role exercised by the Malaysian Qualifications Agency in driving strategic change in higher education cultures, both in public and private universities is described and analysed. The paper…

  2. Leadership in the Reform of Malaysian Universities: Analysing the Strategic Role of the Malaysian Qualifications Agency

    Science.gov (United States)

    Bajunid, Ibrahim Ahmad

    2011-01-01

    This paper addresses the contemporary development and reform challenges in tertiary education in Malaysia in both national and global contexts. The critical role exercised by the Malaysian Qualifications Agency in driving strategic change in higher education cultures, both in public and private universities is described and analysed. The paper…

  3. Office Market Shows Biggest Potential

    Institute of Scientific and Technical Information of China (English)

    LIU BO

    2006-01-01

    @@ As Beijing's residential apartment real estate market slackens thanks to a series of policies proposed by the central government in recent years intended to curb overheated growth, the market for office buildings seems to be upbeat.

  4. 某框架结构办公楼火灾后安全性检测鉴定%THE INSPECTING AND APPRAISING OF A FRAME STRUCTURE OFFICE BUILDING AFTER FIRE HAZARD

    Institute of Scientific and Technical Information of China (English)

    王鑫晔

    2011-01-01

    某框架结构办公楼经过短时间火灾后,建筑材料、构件和结构会存在不同程度的损伤和性能退化,且不同的建筑材料、不同的结构构件存在明显不同的破损现象.为了全面掌握该房屋结构当前的技术状况,需对其进行全面的安全性检测鉴定工作.本文详细地阐述了对某办公楼的火灾后安全性检测鉴定工作,提出了相应的处理建议,对其同类工程有一定的参考价值和借鉴作用.%After the short time fire, the building materials, components of the building structure will have different degrees of damage and performance degradation. Meanwhile, different building materials, different structure component exists obvious different damage phenomenon. In order to fully grasp the current state of the housing structure, its comprehensive safety inspection appraisal is needed. This paper elaborated on the safety of the office building detection and identification, and corresponding recommendations are put forward for the treatment It can provide a reference for other similar projects.

  5. Back office to box office

    DEFF Research Database (Denmark)

    Haigh, Matthew

    sees a mounting unsecured debt where its members see practical value. Between the two, a steward who may not profit from its office delegates it to back-office agents whose fiduciary management is engendered by box office-sized bonuses. Standard theorisation has foundered. The architecture...

  6. 寒冷地区办公建筑被动节能技术应用策略研究*--以天津市城市规划设计研究院科研楼为例%Passive Energy Conservation Technology Application on Office Building in Cold Region:Research Building of Tianjin Urban Planning and Design Institute

    Institute of Scientific and Technical Information of China (English)

    王雯翡; 王连顺

    2015-01-01

    Through analyzing the characteristics of office building in cold region, this paper takes the Research Building of Tianjin Urban Planning and Design Institute as an example, researches the application strategy of the passive energy saving technologies from site planning, natural ventilation, natural lighting, and building shading. The exploring will provide reference experience for the office building in cold region, and also for energy conservation and emission reduction.%通过对寒冷地区办公建筑的气候特点、性能特点、能耗特点分析,以天津市城市规划设计研究院科研楼为研究对象,结合被动节能技术应用策略研究,从建筑场地环境设计策略、调整房间布局改善室内自然通风、高侧窗、采光井、导光筒联合改善自然采光、建筑自遮阳与中空百叶可调节外遮阳等方面进行探索,为寒冷地区办公建筑被动节能技术应用提供参考经验,也为节能减排提供可借鉴的经验。

  7. Integrated population-development program performance: the Malaysian Felda experience.

    Science.gov (United States)

    Fong, C O

    1985-01-01

    Program performance of the Malaysian Felda program, an integrated population development program, is examined in this report. It also evaluates the relationship of the performance of this program with its organizational, integrational, and community support factors. Starting in 1956, Felda had, by the end of 1981, developed 308 land schemes covering an area of 1.4 million acres planted predominantly with oil palm (59.4%) and rubber (31.6%). The land schemes have settled a total of 70,600 families or over 400,000 people. The integrated programs existing in the Felda schmes are the focus of analysis for this study. Out of the universe of 308 Felda schemes, 26 schemes were randomly selected for the study. In each scheme, 2 surveys were conducted: first, the staff surveys to gather information on the organizational factors and extent of integration in existence in the scheme and then household surveys to gather information on the extent of community support for the integrated program and the performance of the program. In the case of the performance variables, the information gathered from the household survey was supplemented by the records from the Felda scheme office. In the sample of 26 schemes, a total of 1641 settler households were selected for the household survey and 363 staff were selected for the staff survey. The surveys were conducted in the 1st quarter of 1982. The results indicate that the Felda mode of delivering population and community development services has been very effective. Over 55.2% of the eligible women were found to be practicing family planning (compared to about 35.5% for the national rural average), while over 78.9% of the eligible women utilized postnatal health care facilities. About 1 in 3 of the eligible children in Felda schemes attend kindergarten classes, while over 46.9% of the Felda households are involved in some form of extramural income generating activities. The more integrated the program in a particular community, the more

  8. Waqf (Endowment Practice in Malaysian Society

    Directory of Open Access Journals (Sweden)

    NUR KHALIDAH DAHLAN

    2014-06-01

    Full Text Available Justice and equality are not identical in the sense that under certain circumstances, justice may only be achieved through inequality or unequal distribution of wealth. The two aspects of justice, which are corrective justice and distributive justice in this definition both comprehend of justice as a social concept as it incorporates social relations and would have little meaning if it were to apply to an individual in total isolation from society. Thus by comparing the pertinent literature on jurisdiction of the courts in terms of waqf and judicial decisions, this article seeks to describe the pros and cons of waqf practices and how it reflects justice to the Malaysian society.

  9. Revitalizing the Malaysian Trade Union Movement

    DEFF Research Database (Denmark)

    Wad, Peter

    2012-01-01

    organizations prefer non-partisan engagement. In order to revitalize themselves, the unions must demonstrate to the Malaysian public that they are both relevant and important for increased productivity and that they can play a significant role in enabling Malaysia to move beyond the middle-income ‘trap’ towards......The article takes an historic perspective on contemporary issues of trade union revival in Malaysia, focusing on the challenge of raising union density and analysing the process of organizing employees in the strategically important electronics industry. It concludes that the political support...

  10. Research on Style of Leadership in Building the Learning Organization in Military Representative Office%学习型军代室建设中的领导方式问题研究

    Institute of Scientific and Technical Information of China (English)

    张春霞; 刘恒; 王珍

    2012-01-01

    The paper analyzes the process of building a learning military affairs representative office and is looking for an effective style of leadership in different phases. Based on the fact of the military representative office, the paper develops Bruce Tuckman's theory and the five phases of building the learning military representative office are put forward, namely, forming, storming, normalizing, performing and innovating phases. The paper analyzes the responsibility of the leaders and points out the role of the model, counselor, participant, inductor and observer the leaders should act in the various phase.%利用学习型组织理论分析学习型军代室建设过程,寻找在军代室建设的各个阶段军代室领导应该采用的有效领导方式.结合军代室工作实际,运用塔克曼团队建设的阶段理论,提出了学习型军代室建设的5个阶段,即形成阶段、震荡阶段、规范阶段、执行阶段和创新阶段.结合团队建设各个阶段的特征,分析了军代室领导应当承担的任务和充当的角色,指出在学习型军代室建设的不同阶段,军代室领导应分别以榜样者、辅导者、参与者、授权者和观察员5种不同的角色出现.

  11. Malaysian group looks to invest in China petchems venture

    Energy Technology Data Exchange (ETDEWEB)

    Alperowicz, N.

    1992-11-25

    The Kuok Group, owned by Malaysian tycoon Robert Kuok, has emerged as the latest potential investor in a petrochemicals joint venture in China. The group, which has assets including the Shangri-La chain of hotels and several urea formaldehyde plants in Malaysia and Singapore, has signed a memorandum of understanding with the local authorities of Beihai, Guangxi province to study a $3-billion refinery and petrochemicals complex. Beihai, in coastal southwestern China, is near the Vietnam border. The project, understood to be in the preliminary scoping phase, would include a 100,000-bbl/day refinery and a world-scale 450,000-m.t./year cracker that would feed a 450,000-m.t./year polyethylene unit. To make the operation competitive, the group is considering building an ethylene cracker and looking for a cheap source of natural gas. It is understood that an undisclosed Western company has joined forces in the joint venture, which is not one of the 14 petrochemicals complexes currently planned in China. Kuok, who has good contacts in China and has just agreed to develop a commercial complex in Shanghai's Zhabei district, has been approached by the Beihai authorities. Beihai, an economic development zone, would like its own refinery. The closest one is in Maoming. A decision is expected by the end of then year.

  12. 夏热冬冷地区办公建筑体形系数对建筑能耗的影响分析%Influence of Building Shape Coefficient on Energy Consumption of Office Buildings in Hot-Summer-and-Cold-Winter Area of China

    Institute of Scientific and Technical Information of China (English)

    林美顺; 潘毅群; 龙惟定

    2015-01-01

    建筑体形系数是体现建筑形态的重要指标,以上海地区的气候条件作为夏热冬冷地区的典型代表,采用动态能耗模拟软件 DeST-c 对办公类建筑进行能耗计算,引用被动容积率的概念,考虑建筑利用自然通风及日光照明的最大潜力,研究建筑体形系数与建筑能耗之间的关系。研究表明,夏热冬冷地区办公建筑体形系数越大,建筑的被动容积率越大,利用自然能源的潜力越大,建筑能耗越低,该结果为被动式建筑设计提供参考。%Building shape coefficient is an important index in building energy efficiency design. This study is based on the concept of passive volume and assumed to fully use of passive energy, natural ventilation and daylighting, in the passive zones of a building. Taking a group of office buildings in Shanghai as an example,with the help of the dynamic simulation software DeST-c, the relationship between the building shape coefficient and building energy consumption is studied. It shows that in hot-summer-and-cold-winter area of China, the bigger shape coefficient, the bigger passive volume ratio, the more potential to use passive energy, the less building total energy demand. It provides a reference for passive building design.

  13. Out of Office: A Study on the Cause of Office Vacancy and Transformation as a Means to Cope and Prevent

    NARCIS (Netherlands)

    Remøy, H.

    2010-01-01

    Office building vacancy is becoming an increasingly visible part of the cityscape. Billboards shout “for rent” and office locations look abandoned even in the middle of the day. Still, new office buildings and locations are being developed, adding up to the built environment. As hardly any office

  14. Out of Office: A Study on the Cause of Office Vacancy and Transformation as a Means to Cope and Prevent

    NARCIS (Netherlands)

    Remøy, H.

    2010-01-01

    Office building vacancy is becoming an increasingly visible part of the cityscape. Billboards shout “for rent” and office locations look abandoned even in the middle of the day. Still, new office buildings and locations are being developed, adding up to the built environment. As hardly any office bu

  15. Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in offices and commercial sector

    OpenAIRE

    Grignon-Massé, Laurent; Marchio, Dominique; Pietrobon, Marco; Pagliano, Lorenzo

    2010-01-01

    International audience; The energy savings achievable in the end-use space cooling depend on a number of variables related to the building envelope, the plants and to some extent the behavior of occupants. They are hence complex to evaluate and consequently often underrepresented in designers, energy managers and policy makers decisions.This paper is based on some results of the European Commission supported project KeepCool2. It discusses a methodology for bottom-up assessment of the energy ...

  16. Impacts Of External Price Shocks On Malaysian Macro Economy-An Applied General Equilibrium Analysis

    Directory of Open Access Journals (Sweden)

    Abul Quasem Al-Amin

    2008-10-01

    Full Text Available This paper examines the impacts of external price shocks in the Malaysian economy. There are three simulations are carried out with different degrees of external shocks using Malaysian Social Accounting Matrix (SAM and Computable General Equilibrium (CGE analysis. The model results indicate that the import price shocks, better known as external price shocks by 15% decreases the domestic production of building and construction sector by 25.87%, hotels, restaurants and entertainment sector by 12.04%, industry sector by 12.02%, agriculture sector by 11.01%, and electricity and gas sector by 9.55% from the baseline. On the import side, our simulation results illustrate that as a result of the import price shocks by 15%, imports decreases significantly in all sectors from base level. Among the scenarios, the largest negative impacts goes on industry sectors by 29.67% followed by building and construction sector by 22.42%, hotels, restaurants and entertainment sector by 19.45%, electricity and gas sector by 13.%, agriculture sector by 12.63% and other service sectors by 11.17%. However significant negative impact goes to the investment and fixed capital investment. It also causes the household income, household consumption and household savings down and increases the cost of livings in the economy results in downward social welfare.

  17. Pedestal-type understructure and an electric heat recovery system make Boston office building high achiever in land use and energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Land use and energy conservation goals are responsible for the unusual pedestal base of Boston's new Fiduciary Trust Building, located in one of the city's oldest sections. The area surrounding South Station and designated for renewal is plagued with a complex traffic situation on the surface and an underground maze of utility lines and conduits and subway tunnels, all of which combined to make innovative construction necessary. Caissons that by-pass underground obstructions support vertical steelwork through a flaring three-story pedestal. Cantilevered trusses provide a platform for the tower floors and allow versatile use of space with esthetically pleasing lines. An original glass-face plan was replaced with 35 percent tinted glass, 20 percent insulation-backed glass, and 45 percent precast concrete in order to conserve energy. Individualized lighting control was accomplished by installing 1000 wall switches to control the 3000 fixtures. Standardized 35-watt four-foot fluorescent tubes and a High Voltage Alternating Current (HVAC) air system allow further energy savings. A stringent new building code is credited with inspiring many of the conservation features. Details of the construction and heat recovery systems include a design summary of the building's construction specifications. (DCK)

  18. On the Use of Integrated Daylighting and Energy Simulations to Drive the Design of a Large Net-Zero Energy Office Building: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Guglielmetti, R.; Pless, S.; Torcellini, P.

    2010-08-01

    This paper illustrates the challenges of integrating rigorous daylight and electric lighting simulation data with whole-building energy models, and defends the need for such integration to achieve aggressive energy savings. Through a case study example, we examine the ways daylighting -- and daylighting simulation -- drove the design of a large net-zero energy project. We give a detailed review of the daylighting and electric lighting design process for the National Renewable Energy Laboratory's Research Support Facility (RSF), a 220,000 ft2 net-zero energy project the author worked on as a daylighting consultant. A review of the issues involved in simulating and validating the daylighting performance of the RSF will be detailed, including daylighting simulation, electric lighting control response, and integration of Radiance simulation data into the building energy model. Daylighting was a key strategy in reaching the contractual energy use goals for the RSF project; the building's program, layout, orientation and interior/furniture design were all influenced by the daylighting design, and simulation was critical in ensuring these many design components worked together in an integrated fashion, and would perform as required to meet a very aggressive energy performance goal, as expressed in a target energy use intensity.

  19. 办公建筑间歇空调附加冷负荷系数及其应用%Additional cooling load coefficient of intermittent air conditioning in office buildings and its application

    Institute of Scientific and Technical Information of China (English)

    林坤平; 徐宏庆

    2012-01-01

    On the basis of the previous research, presents the additional cooling load coefficients for floor, interior walls and furniture of various building materials with different building shape factors and area ratios of window to wall in various climatic zones in China. Works out a calculation table of the additional cooling load coefficient method, and perfects the existing calculating method, providing a reference for project designing. Taking a typical office building as an example, presents the application of the cooling load calculation table.%在前阶段科研的基础上,给出了我国不同气候区、不同建筑体形系数和窗墙面积比情况下,多种建筑材料的楼板、内墙、家具的附加冷负荷系数,并编制了附加冷负荷系数法计算表,补充与完善了现有的计算方法,为工程设计提供参考.通过一个典型办公建筑的计算实例介绍了冷负荷计算表的应用.

  20. INDOOR ENVIRONMENTAL COMFORT IN MALAYSIAN URBAN HOUSING

    Directory of Open Access Journals (Sweden)

    Yaik-Wah Lim

    2013-01-01

    Full Text Available In Malaysia, terraced houses have been rapidly constructed since 50 years ago and account for 44% of the existing urban housings. However, these houses have very limited use of natural ventilation and daylighting due to openings with small window-to-floor ratio. The deep plan design causes gloomy indoor spaces, low air change rate and poor indoor air quality. Studies showed that indoor environments have major impact on occupants’ well-being. Thereby this study evaluates the effects of indoor comforts on occupants’ perceived health in Malaysian typical terraced houses. Survey of terraced houses in Johor Bahru, Malaysia was conducted using questionnaire. Various terraced houses were studied to identify the critical comfort and health issues in terraced housing. The relationships among occupants’ perceived comforts, health and behavior were studied. The variance of types of terraced house was also analyzed. The findings demonstrated significant linear relationships between indoor comfort and health. However, occupants’ behavior did not give significant impact on thermal comfort. This study concludes that it is very essential to improve indoor comfort in Malaysian typical terraced houses through tropical design strategies to enhance occupants’ well-being.

  1. Transcultural Diabetes Nutrition Algorithm: A Malaysian Application

    Science.gov (United States)

    Hamdy, Osama; Chin Chia, Yook; Lin Lim, Shueh; Kumari Natkunam, Santha; Yeong Tan, Ming; Sulaiman, Ridzoni; Nisak, Barakatun; Chee, Winnie Siew Swee; Marchetti, Albert; Hegazi, Refaat A.; Mechanick, Jeffrey I.

    2013-01-01

    Glycemic control among patients with prediabetes and type 2 diabetes mellitus (T2D) in Malaysia is suboptimal, especially after the continuous worsening over the past decade. Improved glycemic control may be achieved through a comprehensive management strategy that includes medical nutrition therapy (MNT). Evidence-based recommendations for diabetes-specific therapeutic diets are available internationally. However, Asian patients with T2D, including Malaysians, have unique disease characteristics and risk factors, as well as cultural and lifestyle dissimilarities, which may render international guidelines and recommendations less applicable and/or difficult to implement. With these thoughts in mind, a transcultural Diabetes Nutrition Algorithm (tDNA) was developed by an international task force of diabetes and nutrition experts through the restructuring of international guidelines for the nutritional management of prediabetes and T2D to account for cultural differences in lifestyle, diet, and genetic factors. The initial evidence-based global tDNA template was designed for simplicity, flexibility, and cultural modification. This paper reports the Malaysian adaptation of the tDNA, which takes into account the epidemiologic, physiologic, cultural, and lifestyle factors unique to Malaysia, as well as the local guidelines recommendations. PMID:24385984

  2. Drivers for Malaysian SMEs to Go Green

    Directory of Open Access Journals (Sweden)

    M. Krishna Moorthy

    2012-09-01

    Full Text Available Small and Medium Enterprises (SMEs around the world have little knowledge about environmental management and do not understand the concept of environmental management. The concept of green is still very new to Malaysian SME owners/managers, although many green conferences, seminars and campaigns have been carried out for quite some time. The concept for green process and products in Malaysia is at the infancy stage. The drivers of environmental behavior in SMEs are relatively under-researched (Worthington & Patton, 2005 and more needs to be done to help SME owner-managers adopt environmental initiatives (Hitchens et al., 2003 as poor environmental performance is not simply the outcome of negative attitudes by SME owner-managers to the environment. This study identifies five key drivers of environmental management practice for SMEs go green. The five drivers are: economic benefits, financial incentives, stakeholders demand, legislation, resources, motivation and knowledge. The Theory of Planned Behavior (TPB is considered as the most appropriate theory to study the drivers of green environment behavior and to investigate the owners’/managers’ perception and attitude towards Malaysian SMEs’ green concept.

  3. Transcultural Diabetes Nutrition Algorithm: A Malaysian Application

    Directory of Open Access Journals (Sweden)

    Zanariah Hussein

    2013-01-01

    Full Text Available Glycemic control among patients with prediabetes and type 2 diabetes mellitus (T2D in Malaysia is suboptimal, especially after the continuous worsening over the past decade. Improved glycemic control may be achieved through a comprehensive management strategy that includes medical nutrition therapy (MNT. Evidence-based recommendations for diabetes-specific therapeutic diets are available internationally. However, Asian patients with T2D, including Malaysians, have unique disease characteristics and risk factors, as well as cultural and lifestyle dissimilarities, which may render international guidelines and recommendations less applicable and/or difficult to implement. With these thoughts in mind, a transcultural Diabetes Nutrition Algorithm (tDNA was developed by an international task force of diabetes and nutrition experts through the restructuring of international guidelines for the nutritional management of prediabetes and T2D to account for cultural differences in lifestyle, diet, and genetic factors. The initial evidence-based global tDNA template was designed for simplicity, flexibility, and cultural modification. This paper reports the Malaysian adaptation of the tDNA, which takes into account the epidemiologic, physiologic, cultural, and lifestyle factors unique to Malaysia, as well as the local guidelines recommendations.

  4. Emergency Management for Disasters in Malaysian Hotel Industry

    Directory of Open Access Journals (Sweden)

    AlBattat Ahmad Rasmi

    2014-01-01

    Full Text Available This paper aims to identify major emergencies that have the potential to place Malaysian hotels in emergency and disaster situations; investigate how hotels were prepared for emergencies, how they manage and overcome emergencies when occurred; and limitations and factors influencing successful emergency planning and adoption emergency management in Malaysian hotels. Face-to-face interview with managers from three, four and five star hotels from different backgrounds: local; regional; and International in Kuala Lumpur, Subang, and Putrajaya are undertaken. The result revealed that Malaysian hotels are exposed to a wide range of natural and man-made disasters. Malaysian hotels lack proactive emergency planning and a lot of constraints which impede successful emergency planning for disasters in the hotel industry in Malaysia, with emphasizing on the relevant authority’s role to demonstrate emergency management to hotels convincing them to adopt such practices, so they can be able to cope with emergencies effectively.

  5. SIMULATION OF FUEL ECONOMY FOR MALAYSIAN URBAN DRIVING

    National Research Council Canada - National Science Library

    M A Abas; M F Muhamad Said; S F Zainal Abidin; I Zahari

    2015-01-01

    ... the residencies at the lower engine speed and load region. This paper presents the validation of the derived engine conditions representing Malaysian actual urban driving in an attempt to formulate representative fuel economy data...

  6. Malaysian diaspora strategies in a globalized Muslim market

    DEFF Research Database (Denmark)

    Fischer, Johan

    2015-01-01

    by this effort. The empirical focus is on London because this city not only holds a special position in the Malaysian state’s halal vision but also historical linkages that evoke diaspora strategies. I argue that Malaysian diaspora strategies should be explored in the interfaces between Islam, state and market......This paper explores Malaysia’s efforts to develop and dominate a global market in halal (literally, ‘lawful or ‘permitted’) commodities as a diaspora strategy and how Malaysian state institutions, entrepreneurs, restaurants and middle-class groups in London respond to and are affected...... and practise Malaysian diaspora strategies in the globalized market for halal products and services. This paper is based on ethnographic material from fieldwork among state institutions, entrepreneurs, restaurants and middle-class groups in Kuala Lumpur and London, namely participant observation...

  7. System Reliability Assessment of Existing Jacket Platforms in Malaysian Waters

    OpenAIRE

    V.J. Kurian; M.C. Voon; M.M.A. Wahab; M.S. Liew

    2014-01-01

    Reliability of offshore platforms has become a very important issue in the Malaysian Oil and Gas Industry as, majority of the jacket platforms in Malaysian waters to date, have exceeded their design life. Reliability of a jacket platform can be assessed through reliability index and probability of failure. Conventional metocean consideration uses 100 year return period wave height associated with 100 year return period current velocity and wind speed. However, recent study shows that for Mala...

  8. Ethics Code Awareness, Usefulness and Professionalism of Malaysian Journalists

    OpenAIRE

    Quah Chun Hoo; Leong Shi Yeing; Guok Eng Chai

    2014-01-01

    The purpose of this research is to explore: a) how Malaysian journalists with idealistic and relativistic orientations perceive their ethical codes, the code’s usefulness and their professionalism? and b) is there any significant difference amongst Malaysian journalists from different language dailies and medium of education in terms of their idealism and relativism? Data was collected from 145 journalists from different dailies in Ipoh and Penang, within Peninsular Malaysia using “convenienc...

  9. Energy saving in office buildings through cheap bioclimatic design measures; Ahorro de energia en edificios de oficinas a partir de medidas de diseno bioclimatico de bajo costo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Chavez, Jose Roberto [Universidad Autonoma Metropolitana, Unidad Azcapotzalco (Mexico)

    2007-01-15

    This article shows the study performed in a building of Campus Uni dad Azcapotzalco in order to evaluate some bioclimatic design strategies. And to reach the higrothermic comfort and the appropriate lighting to favor employees to increase their performance in work activities. There are some strategies in order to solve this problem: the skylight area reduction, existing lights change, ventilation increase, fixed partition door implementation, etc. The obtained outcomes make possible the beginning of bioclimatic design use to save energy in other buildings, because sometimes edifications possess a design that cause the energy waste. [Spanish] En este articulo se muestra el estudio que se hizo en un edificio en el Campus Unidad Azcapotzalco, el fin de esta labor es evaluar ciertas estrategias de diseno bioclimatico para que las personas que operan en este edificio puedan tener confort higrotermico y una iluminacion pertinente, que den como resultado un mejor desempeno en las tareas que realizan. Algunas de las estrategias para darle solucion a esta problematica son: disminuir del area de lucernarios, cambiar las luminarias existentes, aumentar la ventilacion, implementar canceleria, etc. Con los resultados obtenidos nace la esperanza de que se utilicen estrategias de diseno bioclimatico para ahorrar energia en otros edificios, ya que muchas veces las edificaciones poseen un diseno que unicamente provoca el uso imprudente de la energia.

  10. 75 FR 20833 - Building Energy Codes

    Science.gov (United States)

    2010-04-21

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Building Energy Codes AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Request for Information. SUMMARY: The...

  11. 成都某公司办公大楼空调通风设计%Air Conditioning and Ventilation System Design for A Company Office Building in ChengDu City

    Institute of Scientific and Technical Information of China (English)

    何朝烽

    2014-01-01

    The design of air conditioning , ventilation, smoke control and extraction system and air conditioning automatic control system for a company office building in ChengDu City were introduced .The form of air conditioning system was expounded .Fire prevention measure , energy conservation measure ,environmental protection and hygiene and disease control measure of air conditioning and ventilation systems were provided .%介绍了成都某公司办公大楼的空调、通风、防排烟系统和空调自动控制系统设计,详细阐述了空调系统形式,指出了通风空调系统防火措施、节能措施及环保与卫生防疫措施。

  12. Mail office

    CERN Multimedia

    2006-01-01

    Members of the personnel are kindly requested to empty their mail boxes. Any mail remaining in mail boxes will be collected and resorted by Mail Office staff on 6 April. Only specifically addressed mail will be re-delivered.

  13. Mail Office

    CERN Multimedia

    2006-01-01

    Members of the personnel are kindly requested to empty their mail boxes. Any mail remaining in mail boxes will be collected and resorted by Mail Office staff on 1st June. Only specifically addressed mail will be re-delivered.

  14. Perception of masculinity amongst young Malaysian men: a qualitative study of university students

    National Research Council Canada - National Science Library

    Fazli Khalaf, Zahra; Low, Wah Yun; Ghorbani, Behzad; Merghati Khoei, Effat

    2013-01-01

    .... This research aimed to explore the meanings of masculinity among Malaysian university men. This qualitative study utilized in-depth interviews with 34 young Malaysian university men, aged 20-30 years from three main ethnic groups in Malaysia...

  15. Factors affecting commencement and cessation of betel quid chewing behaviour in Malaysian adults

    National Research Council Canada - National Science Library

    Ghani, Wan M N; Razak, Ishak A; Yang, Yi-Hsin; Talib, Norain A; Ikeda, Noriaki; Axell, Tony; Gupta, Prakash C; Handa, Yujiro; Abdullah, Norlida; Zain, Rosnah B

    2011-01-01

    .... Unfortunately, data on Malaysian population is non-existent. This study aims to determine the factors associated with the inception and also cessation of betel quid chewing behaviour among Malaysian adults...

  16. Internet Activities among Malaysian Insurance Companies

    Directory of Open Access Journals (Sweden)

    Tee Chee Kiat

    2005-01-01

    Full Text Available Many studies have been conducted to study Internet usage. Most of them focused on SMI/SME, individuals, services organisations including the financial sector. Previous studies on Internet usage in the financial sector in Malaysia were more focused towards the banking institutions. Not much information is available with regards to the Internet usage among insurance companies. Recognizing the potential of the Internet to insurance companies, the Central Bank of Malaysia (Bank Negara of Malaysia has established guidelines that allow insurers to offer their services online. This study describes the extent of Internet usage among Malaysian insurers. Some insurers have already begun to use the Internet to conduct their daily business transactions, some are in the midst of planning to use and some do not have plan to use at all. Many of them stated that security, customer readiness and cost of initial investment were important considerations when deciding to adopt Internet technologies.

  17. PRICE TRANSMISSION IN SELECTED MALAYSIAN FRUITS MARKETS

    Directory of Open Access Journals (Sweden)

    Fatimah Mohamed Arshad

    2014-01-01

    Full Text Available The market for fresh produce such as fruits in Malaysia is alleged to be inefficient due to poor flow of information between market levels and uncompetitive market particularly at the wholesale and retail levels. Due to these structural problems, pricing efficiency is questionable, in that they are not integrated. This study intends to examine the cointegration and causality relationships between the farm and retail prices in the Malaysian market of fruits. To that end, the bivariate cointegration approach, using Granger causality tests, is applied. The study uses monthly data from January 2000 through December 2010. The results show that there is evidence of long run bidirectional causal relationship between farm and retail prices for banana and watermelon. However, the analysis revealed a long run unidirectional relationship from farm prices to retail prices with no evidence of reverse or feedback causality running from farm price to retail prices for jackfruit and durian.

  18. The Perception of Malaysian Architects towards the Implementation of Green Roofs: A Review of Practices, Methodologies and Future Research

    Directory of Open Access Journals (Sweden)

    Zahir M.H. Md.

    2014-01-01

    Full Text Available The implementation of green roofs or vegetated roof as a sustainable tool to mitigate the Urban Heat Island effect is relatively new in Malaysia. Although it has not been tested on an urban scale, many research findings have indicated that green roofs can contribute towards enhancing the environmental and aesthetical quality of the built environment. It was hypothesized that the low application of green roofs in the Malaysian construction industry is due to the lack of awareness, understanding and experience in its benefits especially among building practitioners. As a result, this research was initiated to determine the perception and understanding of Malaysian architects in green roofs implementation issues, as well as to identify their level of acceptance and readiness. This paper reviews practices and different research approaches in understanding the factors that influence architect’s perception towards the implementation of green roofs in the Malaysian construction industry. Architects were chosen as the only respondents due to their intensive involvement in the conceptualisation, planning, design and construction stage of a built environment project. Extensive literature review was conducted to explore past experiences in green roof implementation and to develop the theoretical framework for this research.

  19. MORPHOLOGICAL CHARACTERISTICS OF MALAYSIAN NATIONAL CRICKET BATSMEN

    Directory of Open Access Journals (Sweden)

    Muhammad Zia Ul Haq

    2016-02-01

    Full Text Available Background: The purpose of this study was to examine the morphological characteristics and physical strength of the Malaysian cricket batsmen. Methods: Twenty four top order batsmen from the Malaysian senior, under-19s and under-16s cricket team were recruited for the study. Twenty six anthropometric, four somatotype and two physical strength variables were measured from all participants. Stature were measured by using stadiometer, calipers for skin-fold, non-stretch tape for girth, sliding caliper for segmental lengths and circumferences (breadths and dynamometers for hand grip and back strength. Cater and heath (1990 equation was used to find the somatotype variables of height-weight ratio, endomorph, mesomorph and ectomorph. One way analysis of variance (ANOVA was used to analyses significant between group differences in the variables. Results: The senior batsmen were significantly higher than under-19s and under-16s in body mass, relax and flex arm girths, forearm girth, chest girth, waist girth, calf girth, bi-acromial breadth, transvers breadth and hand grip strength. Both senior and under-19s batsmen were significantly higher than under-16s batsmen in arm span, total arm length, humerus and femur breadths. The under-16s batsmen were also significantly lesser than senior in hip girths, hand lengths and bi-ilocrist breadth, and from under-19s in sitting height and total leg length. Conclusion: Senior batsmen were significantly higher in the anthropometric measurement of girths, breadth and lengths than U-16 because of 10 years age difference. Future research is essential to confirm the relationship between the anthropometric characteristics of batsmen with the batting technique and performance.

  20. Wave power potential in Malaysian territorial waters

    Science.gov (United States)

    Asmida Mohd Nasir, Nor; Maulud, Khairul Nizam Abdul

    2016-06-01

    Up until today, Malaysia has used renewable energy technology such as biomass, solar and hydro energy for power generation and co-generation in palm oil industries and also for the generation of electricity, yet, we are still far behind other countries which have started to optimize waves for similar production. Wave power is a renewable energy (RE) transported by ocean waves. It is very eco-friendly and is easily reachable. This paper presents an assessment of wave power potential in Malaysian territorial waters including waters of Sabah and Sarawak. In this research, data from Malaysia Meteorology Department (MetMalaysia) is used and is supported by a satellite imaginary obtained from National Aeronautics and Space Administration (NASA) and Malaysia Remote Sensing Agency (ARSM) within the time range of the year 1992 until 2007. There were two types of analyses conducted which were mask analysis and comparative analysis. Mask analysis of a research area is the analysis conducted to filter restricted and sensitive areas. Meanwhile, comparative analysis is an analysis conducted to determine the most potential area for wave power generation. Four comparative analyses which have been carried out were wave power analysis, comparative analysis of wave energy power with the sea topography, hot-spot area analysis and comparative analysis of wave energy with the wind speed. These four analyses underwent clipping processes using Geographic Information System (GIS) to obtain the final result. At the end of this research, the most suitable area to develop a wave energy converter was found, which is in the waters of Terengganu and Sarawak. Besides that, it was concluded that the average potential energy that can be generated in Malaysian territorial waters is between 2.8kW/m to 8.6kW/m.