WorldWideScience

Sample records for maintenance dose influence

  1. Influence of Genotype on Warfarin Maintenance Dose Predictions Produced Using a Bayesian Dose Individualization Tool.

    Science.gov (United States)

    Saffian, Shamin M; Duffull, Stephen B; Roberts, Rebecca L; Tait, Robert C; Black, Leanne; Lund, Kirstin A; Thomson, Alison H; Wright, Daniel F B

    2016-12-01

    A previously established Bayesian dosing tool for warfarin was found to produce biased maintenance dose predictions. In this study, we aimed (1) to determine whether the biased warfarin dose predictions previously observed could be replicated in a new cohort of patients from 2 different clinical settings, (2) to explore the influence of CYP2C9 and VKORC1 genotype on predictive performance of the Bayesian dosing tool, and (3) to determine whether the previous population used to develop the kinetic-pharmacodynamic model underpinning the Bayesian dosing tool was sufficiently different from the test (posterior) population to account for the biased dose predictions. The warfarin maintenance doses for 140 patients were predicted using the dosing tool and compared with the observed maintenance dose. The impact of genotype was assessed by predicting maintenance doses with prior parameter values known to be altered by genetic variability (eg, EC50 for VKORC1 genotype). The prior population was evaluated by fitting the published kinetic-pharmacodynamic model, which underpins the Bayesian tool, to the observed data using NONMEM and comparing the model parameter estimates with published values. The Bayesian tool produced positively biased dose predictions in the new cohort of patients (mean prediction error [95% confidence interval]; 0.32 mg/d [0.14-0.5]). The bias was only observed in patients requiring ≥7 mg/d. The direction and magnitude of the observed bias was not influenced by genotype. The prior model provided a good fit to our data, which suggests that the bias was not caused by different prior and posterior populations. Maintenance doses for patients requiring ≥7 mg/d were overpredicted. The bias was not due to the influence of genotype nor was it related to differences between the prior and posterior populations. There is a need for a more mechanistic model that captures warfarin dose-response relationship at higher warfarin doses.

  2. Influence of CYP3A5 genetic variation on everolimus maintenance dosing after cardiac transplantation.

    Science.gov (United States)

    Lesche, Dorothea; Sigurdardottir, Vilborg; Setoud, Raschid; Englberger, Lars; Fiedler, Georg M; Largiadèr, Carlo R; Mohacsi, Paul; Sistonen, Johanna

    2015-12-01

    Everolimus (ERL) has become an alternative to calcineurin inhibitors (CNIs) due to its renal-sparing properties, especially in heart transplant (HTx) recipients with kidney dysfunction. However, ERL dosing is challenging due to its narrow therapeutic window combined with high interindividual pharmacokinetic variability. Our aim was to evaluate the effect of clinical and genetic factors on ERL dosing in a pilot cohort of 37 HTx recipients. Variants in CYP3A5, CYP3A4, CYP2C8, POR, NR1I2, and ABCB1 were genotyped, and clinical data were retrieved from patient charts. While ERL trough concentration (C0 ) was within the targeted range for most patients, over 30-fold variability in the dose-adjusted ERL C0 was observed. Regression analysis revealed a significant effect of the non-functional CYP3A5*3 variant on the dose-adjusted ERL C0 (p = 0.031). ERL dose requirement was 0.02 mg/kg/d higher in patients with CYP3A5*1/*3 genotype compared to patients with CYP3A5*3/*3 to reach the targeted C0 (p = 0.041). ERL therapy substantially improved estimated glomerular filtration rate (28.6 ± 6.6 mL/min/1.73 m(2)) in patients with baseline kidney dysfunction. Everolimus pharmacokinetics in HTx recipients is highly variable. Our preliminary data on patients on a CNI-free therapy regimen suggest that CYP3A5 genetic variation may contribute to this variability. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Influence of titration schedule and maintenance dose on the tolerability of adjunctive eslicarbazepine acetate: An integrated analysis of three randomized placebo-controlled trials.

    Science.gov (United States)

    Krauss, Gregory; Biton, Victor; Harvey, Jay H; Elger, Christian; Trinka, Eugen; Soares da Silva, Patrício; Gama, Helena; Cheng, Hailong; Grinnell, Todd; Blum, David

    2018-01-01

    To examine the influence of titration schedule and maintenance dose on the incidence and type of treatment-emergent adverse events (TEAEs) associated with adjunctive eslicarbazepine acetate (ESL). Data from three randomized, double-blind, placebo-controlled trials were analyzed. Patients with refractory partial-onset seizures were randomized to maintenance doses of ESL 400, 800, or 1200mg QD (dosing was initiated at 400 or 800mg QD) or placebo. The incidence of TEAEs was analyzed during the double-blind period (2-week titration phase; 12-week maintenance phase), according to the randomized maintenance dose and the titration schedule. 1447 patients were included in the analysis. During the first week of treatment, 62% of patients taking ESL 800mg QD had ≥1 TEAE, vs 35% of those taking 400mg QD and 32% of the placebo group; dizziness, somnolence, nausea, and headache were numerically more frequent in patients taking ESL 800mg than those taking ESL 400mg QD. During the double-blind period, the incidences of common TEAEs were lower in patients who initiated ESL at 400mg vs 800mg QD. For the 800 and 1200mg QD maintenance doses, rates of TEAEs leading to discontinuation were lower in patients who began treatment with 400mg than in those who began taking ESL 800mg QD. Initiation of ESL at 800mg QD is feasible. However, initiating treatment with ESL 400mg QD for 1 or 2 weeks is recommended, being associated with a lower incidence of TEAEs, and related discontinuations. For some patients, treatment may be initiated at 800mg QD, if the need for more immediate seizure reduction outweighs concerns about increased risk of adverse reactions during initiation. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Pneumocystis jiroveci pneumonia prophylaxis during maintenance therapy influences methotrexate/6-mercaptopurine dosing but not event-free survival for childhood acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Levinsen, Mette; Shabaneh, Diana; Bohnstedt, Cathrine

    2012-01-01

    of maintenance therapy. The TMP/SMX2–7 group received lower oral 6MP doses than TMP/SMXnever patients (50.6 vs. 63.9 mg/m2/d; P ANC) (median 1.7 vs. 2.0 × 109/L; P ANC levels (P = 0.04) and male gender (P = 0.......06) were related to reduced EFS. ANC had no effect on EFS among TMP/SMX2–7 patients (P = 0.40) but did for TMP/SMXnever patients (P = 0.02). The difference in the effect on EFS between TMP/SMX2–7 and TMP/SMXnever patients was not significant (P = 0.46). EFS did not differ between TMP/SMX2–7 and TMP...

  5. Development of dose rate estimation system for FBR maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Iizawa, Katsuyuki [Japan Nuclear Cycle Development Inst., Tsuruga Head Office, International Cooperation and Technology Development Center, Tsuruga, Fukui (Japan); Takeuchi, Jun; Yoshikawa, Satoru [Hitachi Engineering Company, Ltd., Hitachi, Ibaraki (Japan); Urushihara, Hiroshi [Ibaraki Hitachi Information Service Co., Ltd., Omika, Ibaraki (Japan)

    2001-09-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  6. Development of dose rate estimation system for FBR maintenance

    International Nuclear Information System (INIS)

    Iizawa, Katsuyuki; Takeuchi, Jun; Yoshikawa, Satoru; Urushihara, Hiroshi

    2001-01-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  7. A pharmacogenetics-based warfarin maintenance dosing algorithm from Northern Chinese patients.

    Directory of Open Access Journals (Sweden)

    Jinxing Chen

    Full Text Available Inconsistent associations with warfarin dose were observed in genetic variants except VKORC1 haplotype and CYP2C9*3 in Chinese people, and few studies on warfarin dose algorithm was performed in a large Chinese Han population lived in Northern China. Of 787 consenting patients with heart-valve replacements who were receiving long-term warfarin maintenance therapy, 20 related Single nucleotide polymorphisms were genotyped. Only VKORC1 and CYP2C9 SNPs were observed to be significantly associated with warfarin dose. In the derivation cohort (n = 551, warfarin dose variability was influenced, in decreasing order, by VKORC1 rs7294 (27.3%, CYP2C9*3(7.0%, body surface area(4.2%, age(2.7%, target INR(1.4%, CYP4F2 rs2108622 (0.7%, amiodarone use(0.6%, diabetes mellitus(0.6%, and digoxin use(0.5%, which account for 45.1% of the warfarin dose variability. In the validation cohort (n = 236, the actual maintenance dose was significantly correlated with predicted dose (r = 0.609, P<0.001. Our algorithm could improve the personalized management of warfarin use in Northern Chinese patients.

  8. A Pharmacogenetics-Based Warfarin Maintenance Dosing Algorithm from Northern Chinese Patients

    Science.gov (United States)

    Luo, Fang; Wang, Jin'e; Shi, Yi; Tan, Yu; Chen, Qianlong; Zhang, Yu; Hui, Rutai; Wang, Yibo

    2014-01-01

    Inconsistent associations with warfarin dose were observed in genetic variants except VKORC1 haplotype and CYP2C9*3 in Chinese people, and few studies on warfarin dose algorithm was performed in a large Chinese Han population lived in Northern China. Of 787 consenting patients with heart-valve replacements who were receiving long-term warfarin maintenance therapy, 20 related Single nucleotide polymorphisms were genotyped. Only VKORC1 and CYP2C9 SNPs were observed to be significantly associated with warfarin dose. In the derivation cohort (n = 551), warfarin dose variability was influenced, in decreasing order, by VKORC1 rs7294 (27.3%), CYP2C9*3(7.0%), body surface area(4.2%), age(2.7%), target INR(1.4%), CYP4F2 rs2108622 (0.7%), amiodarone use(0.6%), diabetes mellitus(0.6%), and digoxin use(0.5%), which account for 45.1% of the warfarin dose variability. In the validation cohort (n = 236), the actual maintenance dose was significantly correlated with predicted dose (r = 0.609, Pwarfarin use in Northern Chinese patients. PMID:25126975

  9. [Clinical applications of dosing algorithm in the predication of warfarin maintenance dose].

    Science.gov (United States)

    Huang, Sheng-wen; Xiang, Dao-kang; An, Bang-quan; Li, Gui-fang; Huang, Ling; Wu, Hai-li

    2011-12-27

    To evaluate the feasibility of clinical application for genetic based dosing algorithm in the predication of warfarin maintenance dose in Chinese population. The clinical data were collected and blood samples harvested from a total of 126 patients undergoing heart valve replacement. The genotypes of VKORC1 and CYP2C9 were determined by melting curve analysis after PCR. They were divided randomly into the study and control groups. In the study group, the first three doses of warfarin were prescribed according to the predicted warfarin maintenance dose while warfarin was initiated at 2.5 mg/d in the control group. The warfarin doses were adjusted according to the measured international normalized ratio (INR) values. And all subjects were followed for 50 days after an initiation of warfarin therapy. At the end of a 50-day follow-up period, the proportions of the patients on a stable dose were 82.4% (42/51) and 62.5% (30/48) for the study and control groups respectively. The mean durations of reaching a stable dose of warfarin were (27.5 ± 1.8) and (34.7 ± 1.8) days and the median durations were (24.0 ± 1.7) and (33.0 ± 4.5) days in the study and control groups respectively. Significant differences existed in the durations of reaching a stable dose between the two groups (P = 0.012). Compared with the control group, the hazard ratio (HR) for the duration of reaching a stable dose was 1.786 in the study group (95%CI 1.088 - 2.875, P = 0.026). The predicted dosing algorithm incorporating genetic and non-genetic factors may shorten the duration of achieving efficiently a stable dose of warfarin. And the present study validates the feasibility of its clinical application.

  10. Warfarin maintenance dose in older patients: higher average dose and wider dose frequency distribution in patients of African ancestry than those of European ancestry.

    Science.gov (United States)

    Garwood, Candice L; Clemente, Jennifer L; Ibe, George N; Kandula, Vijay A; Curtis, Kristy D; Whittaker, Peter

    2010-06-15

    Studies report that warfarin doses required to maintain therapeutic anticoagulation decrease with age; however, these studies almost exclusively enrolled patients of European ancestry. Consequently, universal application of dosing paradigms based on such evidence may be confounded because ethnicity also influences dose. Therefore, we determined if warfarin dose decreased with age in Americans of African ancestry, if older African and European ancestry patients required different doses, and if their daily dose frequency distributions differed. Our chart review examined 170 patients of African ancestry and 49 patients of European ancestry cared for in our anticoagulation clinic. We calculated the average weekly dose required for each stable, anticoagulated patient to maintain an international normalized ratio of 2.0 to 3.0, determined dose averages for groups 80 years of age and plotted dose as a function of age. The maintenance dose in patients of African ancestry decreased with age (PAfrican ancestry required higher average weekly doses than patients of European ancestry: 33% higher in the 70- to 79-year-old group (38.2+/-1.9 vs. 28.8+/-1.7 mg; P=0.006) and 52% in the >80-year-old group (33.2+/-1.7 vs. 21.8+/-3.8 mg; P=0.011). Therefore, 43% of older patients of African ancestry required daily doses >5mg and hence would have been under-dosed using current starting-dose guidelines. The dose frequency distribution was wider for older patients of African ancestry compared to those of European ancestry (PAfrican ancestry indicate that strategies for initiating warfarin therapy based on studies of patients of European ancestry could result in insufficient anticoagulation and thereby potentially increase their thromboembolism risk. Copyright 2010 Elsevier Inc. All rights reserved.

  11. Mechanisms of lower maintenance dose of tacrolimus in obese patients.

    Science.gov (United States)

    Sawamoto, Kazuki; Huong, Tran T; Sugimoto, Natsumi; Mizutani, Yuka; Sai, Yoshimichi; Miyamoto, Ken-ichi

    2014-01-01

    A retrospective analysis suggested that blood tacrolimus concentrations were consistent among patients with a body mass index (BMI) that was lean (maintenance dose of tacrolimus in patients with BMI ≥ 25 was significantly lower compared with that in patients with a BMI of less than 25. Lean and obese Zucker rats fed a normal diet were given tacrolimus intravenously or orally. The blood concentrations of tacrolimus in obese rats were significantly higher than those in lean rats after administration via both routes. The moment analysis has suggested that CLtot and Vdss of tacrolimus were not significantly different between lean and obese rats. The bioavailability was higher in obese rats, compared with that in lean rats. The protein expression of Cyp3a2 in the liver was significantly decreased in obese rats, compared with lean rats, while P-gp in the small intestine was also significantly decreased in obese rats. These results suggested that the steady-state trough concentration of tacrolimus in obese patients was well maintained by a relatively low dose compared with that in normal and lean patients, presumably due to increased bioavailability.

  12. Effects of VKORC1 Genetic Polymorphisms on Warfarin Maintenance Dose Requirement in a Chinese Han Population

    Science.gov (United States)

    Yan, Xiaojuan; Yang, Feng; Zhou, Hanyun; Zhang, Hongshen; Liu, Jianfei; Ma, Kezhong; Li, Yi; Zhu, Jun; Ding, Jianqiang

    2015-01-01

    Background VKORC1 is reported to be capable of treating several diseases with thrombotic risk, such as cardiac valve replacement. Some single-nucleotide polymorphisms (SNPs) in VKORC1 are documented to be associated with clinical differences in warfarin maintenance dose. This study explored the correlations of VKORC1–1639 G/A, 1173 C/T and 497 T/G genetic polymorphisms with warfarin maintenance dose requirement in patients undergoing cardiac valve replacement. Material/Methods A total of 298 patients undergoing cardiac valve replacement were recruited. During follow-up, clinical data were recorded. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method was applied to detect VKORC1–1639 G/A, 1173 C/T and 497 T/G polymorphisms, and genotypes were analyzed. Results Correlations between warfarin maintenance dose and baseline characteristics revealed statistical significances of age, gender and operation methods with warfarin maintenance dose (all PWarfarin maintenance dose in VKORC1–1639 G/A AG + GG carriers was obviously higher than in AA carriers (Pwarfarin maintenance dose was apparently higher in patients with CT genotype (Pwarfarin maintenance dose (all Pwarfarin maintenance dose in patients undergoing cardiac valve replacement; meanwhile, gender, operation method and method for heart valve replacement might also be correlate with warfarin maintenance dose. PMID:26583785

  13. Influence Diagrams for Optimal Maintenance Planning

    DEFF Research Database (Denmark)

    Friis-Hansen, Andreas

    2000-01-01

    Over the last two decades Bayesian networks and influence diagrams have received notable attention within the field of artificial intelligence and expert systems. During the last few years the technology has been further developed for problem solving within other engineering fields. The objective...... of this study is to present a conceptual bayesian network model for probabilistic prediction of fatigue crack growth in welded steel tubes. It is shown that despite discretization of the variable domain, the prediction is in good agreement with results obtained by the well-established structural reliability...

  14. Modeling of preventive maintenance changes influence upon flight safety indexes

    Directory of Open Access Journals (Sweden)

    А.В. Гончаренко

    2004-03-01

    Full Text Available  It is considered a simplified model of connection between the catastrophic events flow frequency and both preventive maintenance changes periodicity and diagnosis depth of aviation equipment. It is deduced specific formulas for computing the changes and diagnostics parameters influence upon the values of both the catastrophic events flow frequency and technical-economical control factor criterion of flight safety levels.

  15. The effect of high-dose dronabinol (oral THC) maintenance on cannabis self-administration.

    Science.gov (United States)

    Schlienz, Nicolas J; Lee, Dustin C; Stitzer, Maxine L; Vandrey, Ryan

    2018-06-01

    There is a clear need for advancing the treatment of cannabis use disorders. Prior research has demonstrated that dronabinol (oral THC) can dose-dependently suppress cannabis withdrawal and reduce the acute effects of smoked cannabis. The present study was conducted to evaluate whether high-dose dronabinol could reduce cannabis self-administration among daily users. Non-treatment seeking daily cannabis users (N = 13) completed a residential within-subjects crossover study and were administered placebo, low-dose dronabinol (120 mg/day; 40 mg tid), or high-dose dronabinol (180-240 mg/day; 60-80 mg tid) for 12 consecutive days (order counterbalanced). During each 12-day dronabinol maintenance phase, participants were allowed to self-administer smoked cannabis containing <1% THC (placebo) or 5.7% THC (active) under forced-choice (drug vs. money) or progressive ratio conditions. Participants self-administered significantly more active cannabis compared with placebo in all conditions. When active cannabis was available, self-administration was significantly reduced during periods of dronabinol maintenance compared with placebo maintenance. There was no difference in self-administration between the low- and high-dose dronabinol conditions. Chronic dronabinol dosing can reduce cannabis self-administration in daily cannabis users and suppress withdrawal symptoms. Cannabinoid agonist medications should continue to be explored for therapeutic utility in the treatment of cannabis use disorders. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. A review of a priori regression models for warfarin maintenance dose prediction.

    Directory of Open Access Journals (Sweden)

    Ben Francis

    Full Text Available A number of a priori warfarin dosing algorithms, derived using linear regression methods, have been proposed. Although these dosing algorithms may have been validated using patients derived from the same centre, rarely have they been validated using a patient cohort recruited from another centre. In order to undertake external validation, two cohorts were utilised. One cohort formed by patients from a prospective trial and the second formed by patients in the control arm of the EU-PACT trial. Of these, 641 patients were identified as having attained stable dosing and formed the dataset used for validation. Predicted maintenance doses from six criterion fulfilling regression models were then compared to individual patient stable warfarin dose. Predictive ability was assessed with reference to several statistics including the R-square and mean absolute error. The six regression models explained different amounts of variability in the stable maintenance warfarin dose requirements of the patients in the two validation cohorts; adjusted R-squared values ranged from 24.2% to 68.6%. An overview of the summary statistics demonstrated that no one dosing algorithm could be considered optimal. The larger validation cohort from the prospective trial produced more consistent statistics across the six dosing algorithms. The study found that all the regression models performed worse in the validation cohort when compared to the derivation cohort. Further, there was little difference between regression models that contained pharmacogenetic coefficients and algorithms containing just non-pharmacogenetic coefficients. The inconsistency of results between the validation cohorts suggests that unaccounted population specific factors cause variability in dosing algorithm performance. Better methods for dosing that take into account inter- and intra-individual variability, at the initiation and maintenance phases of warfarin treatment, are needed.

  17. A review of a priori regression models for warfarin maintenance dose prediction.

    Science.gov (United States)

    Francis, Ben; Lane, Steven; Pirmohamed, Munir; Jorgensen, Andrea

    2014-01-01

    A number of a priori warfarin dosing algorithms, derived using linear regression methods, have been proposed. Although these dosing algorithms may have been validated using patients derived from the same centre, rarely have they been validated using a patient cohort recruited from another centre. In order to undertake external validation, two cohorts were utilised. One cohort formed by patients from a prospective trial and the second formed by patients in the control arm of the EU-PACT trial. Of these, 641 patients were identified as having attained stable dosing and formed the dataset used for validation. Predicted maintenance doses from six criterion fulfilling regression models were then compared to individual patient stable warfarin dose. Predictive ability was assessed with reference to several statistics including the R-square and mean absolute error. The six regression models explained different amounts of variability in the stable maintenance warfarin dose requirements of the patients in the two validation cohorts; adjusted R-squared values ranged from 24.2% to 68.6%. An overview of the summary statistics demonstrated that no one dosing algorithm could be considered optimal. The larger validation cohort from the prospective trial produced more consistent statistics across the six dosing algorithms. The study found that all the regression models performed worse in the validation cohort when compared to the derivation cohort. Further, there was little difference between regression models that contained pharmacogenetic coefficients and algorithms containing just non-pharmacogenetic coefficients. The inconsistency of results between the validation cohorts suggests that unaccounted population specific factors cause variability in dosing algorithm performance. Better methods for dosing that take into account inter- and intra-individual variability, at the initiation and maintenance phases of warfarin treatment, are needed.

  18. VKORC1 polymorphisms and warfarin maintenance dose in population of Sakha (Yakuts).

    Science.gov (United States)

    Chertovskikh, Y V; Malova, E U; Maksimova, N R; Popova, N V; Sychev, D A

    2015-01-01

    Vitamin K antagonists are effective in the prevention and treatment of thromboembolic disorders. Warfarin is one of the most widely prescribed vitamin K antagonists in the world [1, 2]. It has a narrow therapeutic range and a given dose may result in a large inter-individual variation of response. Insufficient dose may fail to prevent thromboembolism, while an overdose increases the risk of bleeding. Patient-specific factors (e.g., age, body size, race, concurrent diseases, and medications) explain some of the variability in warfarin dosage, but genetic factors influencing warfarin response explain a significantly higher proportion of this variability [3]. Molecular analysis of the gene that encodes the target enzyme vitamin K epoxide reductase complex 1 (VKORC1) strongly suggests that its genetic variations greatly affect the individual response to oral anticoagulants [4-7]. To evaluate effects of VKORC1 polymorphisms on warfarin dose excess anticoagulation (INR >4.0) in the population of Sakha (S) patients. 53 patients (29-women, 24-men) with atrial fibrillation (68%), congestive heart failure (60%), hypertension (49%) and cardiac valve replacement (26%) were recruited. The age range was 26-80 years, with a mean age of 62.87 ± 12.57 years.International normalized ratio and plasma warfarin concentrations were determined. Genotyping was carried out by RT-PCR (real-time PCR). The three genetic polymorphisms of the gene VKORC1 G3673A (rs9923231) were studied: normal (GG), heterozygous (GA) and homozygous (AA). Fisher exact probability test and chi-square test (with Yates correction) were applied to compare data among the AA and GG + GA groups; also Mann-Whitney test was used. The median maintenance daily dose of warfarin among AA carriers was 3.0 mg/day [1.25-7.5 mg], while in GG and GA patients it was 3.13 mg/day [1.88-7.92 mg]. The mean daily warfarin dosage was higher in GG and GA genotype carriers 4.05 mg/day (SD ± 1.7) than in patients with AA genotype 3

  19. The dose effects of short-term dronabinol (oral THC) maintenance in daily cannabis users.

    Science.gov (United States)

    Vandrey, Ryan; Stitzer, Maxine L; Mintzer, Miriam Z; Huestis, Marilyn A; Murray, Jeannie A; Lee, Dayong

    2013-02-01

    Prior studies have separately examined the effects of dronabinol (oral THC) on cannabis withdrawal, cognitive performance, and the acute effects of smoked cannabis. A single study examining these clinically relevant domains would benefit the continued evaluation of dronabinol as a potential medication for the treatment of cannabis use disorders. Thirteen daily cannabis smokers completed a within-subject crossover study and received 0, 30, 60 and 120mg dronabinol per day for 5 consecutive days. Vital signs and subjective ratings of cannabis withdrawal, craving and sleep were obtained daily; outcomes under active dose conditions were compared to those obtained under placebo dosing. On the 5th day of medication maintenance, participants completed a comprehensive cognitive performance battery and then smoked five puffs of cannabis for subjective effects evaluation. Each dronabinol maintenance period occurred in a counterbalanced order and was separated by 9 days of ad libitum cannabis use. Dronabinol dose-dependently attenuated cannabis withdrawal and resulted in few adverse side effects or decrements in cognitive performance. Surprisingly, dronabinol did not alter the subjective effects of smoked cannabis, but cannabis-induced increases in heart rate were attenuated by the 60 and 120mg doses. Dronabinol's ability to dose-dependently suppress cannabis withdrawal may be therapeutically beneficial to individuals trying to stop cannabis use. The absence of gross cognitive impairment or side effects in this study supports safety of doses up to 120mg/day. Continued evaluation of dronabinol in targeted clinical studies of cannabis treatment, using an expanded range of doses, is warranted. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Methadone dose increase and abstinence reinforcement for treatment of continued heroin use during methadone maintenance.

    Science.gov (United States)

    Preston, K L; Umbricht, A; Epstein, D H

    2000-04-01

    Although methadone maintenance is an effective therapy for heroin dependence, some patients continue to use heroin and may benefit from therapeutic modifications. This study evaluated a behavioral intervention, a pharmacological intervention, and a combination of both interventions. Throughout the study all patients received daily methadone hydrochloride maintenance (initially 50 mg/d orally) and weekly counseling. Following baseline treatment patients who continued to use heroin were randomly assigned to 1 of 4 interventions: (1) contingent vouchers for opiate-negative urine specimens (n = 29 patients); (2) methadone hydrochloride dose increase to 70 mg/d (n = 31 patients); (3) combined contingent vouchers and methadone dose increase (n = 32 patients); and (4) neither intervention (comparison standard; n = 28 patients). Methadone dose increases were double blind. Vouchers had monetary value and were exchangeable for goods and services. Groups not receiving contingent vouchers received matching vouchers independent of urine test results. Primary outcome measure was opiate-negative urine specimens (thrice weekly urinalysis). Contingent vouchers and a methadone dose increase each significantly increased the percentage of opiate-negative urine specimens during intervention. Contingent vouchers, with or without a methadone dose increase, increased the duration of sustained abstinence as assessed by urine screenings. Methadone dose increase, with or without contingent vouchers, reduced self-reported frequency of use and self-reported craving. In patients enrolled in a methadone-maintainence program who continued to use heroin, abstinence reinforcement and a methadone dose increase were each effective in reducing use. When combined, they did not dramatically enhance each other's effects on any 1 outcome measure, but they did seem to have complementary benefits.

  1. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  2. Azithromycin maintenance therapy in patients with cystic fibrosis : A dose advice based on a review of pharmacokinetics, efficacy, and side effects

    NARCIS (Netherlands)

    Wilms, Erik B.; Touw, Daniel J.; Heijerman, Harry G.M.; Van Der Ent, Cornelis K.

    Azithromycin maintenance therapy results in improvement of respiratory function in patients with cystic fibrosis (CF). In azithromycin maintenance therapy, several dosing schemes are applied. In this review, we combine current knowledge about azithromycin pharmacokinetics with the dosing schedules

  3. Adjustable Maintenance Dosing with Budesonide/Formoterol Reduces Asthma Exacerbations Compared with Traditional Fixed Dosing: A Five-Month Multicentre Canadian Study

    Directory of Open Access Journals (Sweden)

    J Mark FitzGerlad

    2003-01-01

    Full Text Available BACKGROUND: Adjustable maintenance dosing with budesonide/formoterol in a single inhaler (Symbicort, AstraZeneca, Lund, Sweden may provide a convenient means of maintaining asthma control with the minimum effective medication level.

  4. Application of estimating effective dose from external radiation using two dosimeters during maintenance periods at KNPPS

    International Nuclear Information System (INIS)

    Kim, Hee Geun; Kong, Tae Young

    2008-01-01

    The application of a two-dosimeter and its algorithm and a test of its use in an inhomogeneous high radiation field are described. The goal was to develop an improved method for estimating the effective dose during maintenance periods at Korean nuclear power plants (NPPs). The use of the method in domestic and international NPPs including USA, Canada and Japan was also investigated. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, Lakshmanan, NCRP, EPRI and Texas A and M University were extensively analyzed as two-dosimeter algorithms. The possibility of their application to NPPs was evaluated using data for each algorithm from two-dosimeter results for an inhomogeneous high radiation field during maintenance periods at Korean NPPs. (author)

  5. Influence of Non-safety Important Component on Maintenance Rule

    International Nuclear Information System (INIS)

    Ju, Tae Young; Kim, Wang Bae

    2016-01-01

    The Maintenance Rule (MR) programs in KHNP have been implemented since Jan 2009. KHNP is currently developing MR program for new built plant which has been constructed from December 2011. It is required to utilize plant-specific probabilistic safety analysis (PSA) result as risk significant criteria to determine which components are significantly important to safety. The criteria consist of three PSA risk values which are risk reduction worth (RRW), risk achievement worth (RAW) and core damage frequency (CDF) contribution. Most safety related components are classified as high risk significant, and non-safety related components as low safety significant in MR program. This paper presents the influence of the non-safety related component which has high PSA risk value on MR program of new built plant. It is considered that safety related system has at least one or more safety functions and some non-safety functions, but non-safety system doesn't have any safety function. The safety functions are defined as three functions which are required to maintain 1) integrity of reactor coolant pressure boundary, 2) capability to shut-down the reactor and maintain it in a safe shutdown, and 3) capability to prevent or mitigate the accident that could result in potential offsite exposure. The Maintenance Rule program is developed based on PSA result. Safety functions have high risk value in PSA program and considered HSS function in MR program. On the contrary, non-safety functions are generally has low risk value in PSA program and they are determined as LSS function in MR program. The AAC DG and its supporting systems are designed as non-safety systems which mean they don't have any safety function. But, AAC DG is treated as an important measure to mitigate accident in PSA program. It is determined as HSS function in MR program because it has high risk value in PSA program. AAC DG supporting systems does not have high risk value in operating plant's PSA program

  6. Skin dose variation: influence of energy

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: This research aimed to quantitatively evaluate the differences in percentage dose of maximum for 6MV and 18MV x-ray beams within the first lcm of interactions. Thus provide quantitative information regarding the basal, dermal and subcutaneous dose differences achievable with these two types of high-energy x-ray beams. Percentage dose of maximum build up curves are measured for most clinical field sizes using 6MV and 18MV x-ray beams. Calculations are performed to produce quantitative results highlighting the percentage dose of maximum differences delivered to various depths within the skin and subcutaneous tissue region by these two beams Results have shown that basal cell layer doses are not significantly different for 6MV and 18Mv x-ray beams At depths beyond the surface and basal cell layer there is a measurable and significant difference in delivered dose. This variation increases to 20% of maximum and 22% of maximum at Imm and 1cm depths respectively. The percentage variations are larger for smaller field sizes where the photon in phantom component of the delivered dose is the most significant contributor to dose By producing graphs or tables of % dose differences in the build up region we can provide quantitative information to the oncologist for consideration (if skin and subcutaneous tissue doses are of importance) during the beam energy selection process for treatment. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  7. CYP2D6 Genetic Variation and Beta-Blocker Maintenance Dose in Patients with Heart Failure.

    Science.gov (United States)

    Luzum, Jasmine A; Sweet, Kevin M; Binkley, Philip F; Schmidlen, Tara J; Jarvis, Joseph P; Christman, Michael F; Sadee, Wolfgang; Kitzmiller, Joseph P

    2017-08-01

    This study examined whether a CYP2D6 polymorphism (CYP2D6*4) was related to beta-blocker maintenance dose in patients with heart failure. Logistic regression modeling was utilized in a retrospective chart-review analysis of heart-failure patients (60% Male, 90% of European descent) to assess whether CYP2D6*4 (non-functional CYP2D6 allele present in 1 of 5 individuals of European descent) is associated with maintenance dose of carvedilol (n = 65) or metoprolol (n = 33). CYP2D6*4 was associated with lower maintenance dose of metoprolol (OR 0.13 [95% CI 0.02-0.75] p = 0.023), and a trend was observed between CYP2D6*4 and higher maintenance dose of carvedilol (OR 2.94 [95% CI 0.84-10.30] p = 0.093). None of the patients that carried CYP2D6*4 achieved the recommended target dose of metoprolol (200 mg/day). Consistent with the role of CYP2D6 in the metabolism of metoprolol, the tolerated maintenance dose of metoprolol was lower in CYP2D6*4 carriers compared to non-carriers. Consistent with the role of CYP2D6 in activation of carvedilol, tolerated maintenance dose of carvedilol was higher in CYP2D6*4 carriers compared to non-carriers. Further investigation is warranted to ascertain the potential of CYP2D6 as a potential predictive biomarker of beta-blocker maintenance dose in heart failure patients.

  8. Effect of CYP2C9, VKORC1, CYP4F2 and GGCX genetic variants on warfarin maintenance dose and explicating a new pharmacogenetic algorithm in South Indian population.

    Science.gov (United States)

    Krishna Kumar, Dhakchinamoorthi; Shewade, Deepak Gopal; Loriot, Marie-Anne; Beaune, Philippe; Balachander, Jayaraman; Sai Chandran, B V; Adithan, Chandrasekaran

    2014-01-01

    To determine the influence of genetic polymorphisms on warfarin maintenance dose and to explicate an algorithm using the pharmacogenetic and clinical factors to determine the maintenance and/or starting dose of warfarin in South Indian patients receiving warfarin therapy. Patients receiving stabilized warfarin therapy (n=257) were included in the study. Single nucleotide polymorphisms (SNPs) of CYP2C9 (rs1799853 and rs1057910), VKORC1 (rs9923231, rs7196161, rs2884737, rs9934438, rs8050894, rs2359612 and rs7294), CYP4F2 (rs2108622) and GGCX (rs11676382) were genotyped by the quantitative real time-PCR method. The mean daily maintenance dose of warfarin was found to be 4.7 ± 2.1 mg/day. Patients with the CYP2C9*1/*2, *1/*3 and *2/*3 variant genotypes required a 51.0 (2.8 mg), 60.9 (2.3 mg) and 62.2 % (2.2 mg) lower daily maintenance dose of warfarin, respectively, than those patients with the CYP2C9*1/*1 wild-type genotype (5.2 mg) (pmaintenance dose. Genetic polymorphisms of CYP2C9, VKORC1, CYP4F2 and GGCX are important predictive factors of warfarin maintenance dose, and the developed algorithm will be useful to predict the required maintenance and/or starting warfarin dose in South Indian populations.

  9. Biological influence from low dose and low-dose rate radiation

    International Nuclear Information System (INIS)

    Magae, Junji

    2007-01-01

    Although living organisms have defense mechanisms for radioadaptive response, the influence is considered to vary qualitatively and quantitatively for low dose and high dose, as well as for low-dose rate and high-dose rate. This article describes the bioresponse to low dose and low-dose rate. Among various biomolecules, DNA is the most sensitive to radiation, and accurate replication of DNA is an essential requirement for the survival of living organisms. Also, the influence of active enzymes resulted from the effect of radiation on enzymes in the body is larger than the direct influence of radiation on the body. After this, the article describes the carcinogenic risk by low-dose radiation, and then so-called Hormesis effect to create cancer inhibition effect by stimulating active physiology. (S.K.)

  10. Influencing factors for condition-based maintenance in railway tracks using knowledge-based approach

    NARCIS (Netherlands)

    Jamshidi, A.; Hajizadeh, S.; Naeimi, M.; Nunez Vicencio, Alfredo; Li, Z.

    2017-01-01

    In this paper, we present a condition-based maintenance decision method using
    knowledge-based approach for rail surface defects. A railway track may contain a considerable number of surface defects which influence track maintenance decisions. The proposed method is based on two sets of

  11. Dose-Dependent Effects of Methadone on QT interval in Patients under Methadone Maintenance Treatment

    Directory of Open Access Journals (Sweden)

    Farzad Gheshlaghi

    2013-03-01

    Full Text Available Background: The role of methadone in QTc prolongation, Torsades de Pointes (TdP arrhythmia and sudden cardiac death has been debated. Because of widespread use of methadone in methadone maintenance treatment (MMT centers, we aimed to study dose-related effects of methadone on QTc prolongation. Methods: In a comparative observational study, 90 patients who were under MMT were evaluated. Patients were divided into three groups according to methadone daily dose (G1: 0-59 mg, G2: 60-109 mg, G3: 110-150 mg. Twelve-lead electrocardiograms (ECG were performed at baseline and two months later, after reaching the maximum daily dose of methadone. The QTc were calculated for each patient. Comparison of mean QTc and mean QTc prolongation between baseline and follow up ECGs were analyzed. Results: In total, mean (SD age was 32.4 (8.5. TdP was not detected in any patients. Mean QTc was 405.2 (17.0 and 418.5 (23.1 msec before and two months after MMT respectively. There was a significant difference between mean QTc in each group before and after treatment (P

  12. Compact and maintenance-free radio probes for environmental surveillance of the gamma dose rate

    International Nuclear Information System (INIS)

    Genrich, V.

    1998-01-01

    The author reports on his experience with the operation of radio data networks for the continuous observation of the gamma dose rate in nuclear installations. Practically at every location (within) the installation the hermetically sealed probes can record the measurement values. Moreover, the probes have proved successful in environmental surveillance where they typically work in the form of measurement rings in 10 to 30 km distance. All measurement data are organized in the form of a data base. They can be disposed of in the form of an SQL-server in the computer network (LAN) of the power plant or the institution in charge of environmental surveillance. In comparison to conventional, e.g. cable-bound measurement networks with the new radio transmission technology there are numerous advantages: - minimal cost for projection - minimal cost for installation due to simple fixing - quasi-mobile use with highest possible flexibility - maintenance-free operation and high degree of operating reliability. (orig.) [de

  13. Prelimanary Investigation on The Factors That Influencing The Maintenance Cost of Apartment

    Directory of Open Access Journals (Sweden)

    Salleh Nor Aini

    2016-01-01

    Full Text Available Housing is a basic need for all. The increasing numbers of population and income had increase in housing demand. Thus, it has led to the construction of apartments to meet the needs of people and to reduce the use of land to build residential buildings. From year to year, maintenance costs of the building are increased. To ensure the maintenance cost for apartment residence maintenance can be reduced, it is important to determine the factor that influence the maintenance cost of the apartment. This paper is to investigate and identify the factors contributing the increase of maintenance costs. The first objective of this study is to determine the factors that affect the cost of maintaining the apartment and meanwhile the second objective is to rank the factors that influence the maintenance cost of the apartment at Johor Baharu Tengah. To achieve the objectives of the study, the questionnaires were distributed to the parties involved in the management of building. Results of this study concluded that there are five factors that influence maintenance cost are the expectations of tenants, building age, building material, failure to execute maintenance at the right time and budget constraints.

  14. ALARA review of the maintenance and repair jobs of repetitive high radiation dose at Kori Unit 3 and 4

    International Nuclear Information System (INIS)

    Cho, Y.H.; Moon, J.H.; Kang, C.S.; Lee, J.S.; Lee, D.H.

    2003-01-01

    The policy of maintaining occupational radiation dose (ORD) as low as reasonably achievable (ALARA) requires the effective reduction of ORD in the phases of design as well as operation of nuclear power plants. It has been identified that a predominant portion of ORD arises during maintenance and repair operations at nuclear power plants. The cost-effective reduction of ORD cannot be achieved without a comprehensive analysis of accumulated ORD data of existing nuclear power plants. To identify the jobs of repetitive high ORD, the ORD data of Kori Units 3 and 4 over 10-year period from 1986 to 1995 were compiled into the PC-based ORD database program. As the radiation job classification structure, 26 main jobs are considered, most of which are further subdivided into detailed jobs. According to the order of the collective dose values for 26 main jobs, 10 jobs of high collective dose are identified. As an ALARA review, then, top 10 jobs of high collective dose are statistically analyzed with regard to 1) dose rate, 2) crew number and 3) job frequency that are the factors determining the collective dose for the radiation job of interest. Through the ALARA review, main reasons causing to high collective dose values are identified as follows. The high collective dose of RCP maintenance job is mainly due to the large crew number and the high job frequency. The characteristics of refueling job are similar to those of RCP maintenance job. However, the high collective doses of SG-related jobs such as S/G nozzle dam job, S/G man-way job and S/G tube maintenance job are mainly due to high radiation dose rate. (author)

  15. Using adaptive model predictive control to customize maintenance therapy chemotherapeutic dosing for childhood acute lymphoblastic leukemia.

    Science.gov (United States)

    Noble, Sarah L; Sherer, Eric; Hannemann, Robert E; Ramkrishna, Doraiswami; Vik, Terry; Rundell, Ann E

    2010-06-07

    Acute lymphoblastic leukemia (ALL) is a common childhood cancer in which nearly one-quarter of patients experience a disease relapse. However, it has been shown that individualizing therapy for childhood ALL patients by adjusting doses based on the blood concentration of active drug metabolite could significantly improve treatment outcome. An adaptive model predictive control (MPC) strategy is presented in which maintenance therapy for childhood ALL is personalized using routine patient measurements of red blood cell mean corpuscular volume as a surrogate for the active drug metabolite concentration. A clinically relevant mathematical model is developed and used to describe the patient response to the chemotherapeutic drug 6-mercaptopurine, with some model parameters being patient-specific. During the course of treatment, the patient-specific parameters are adaptively identified using recurrent complete blood count measurements, which sufficiently constrain the patient parameter uncertainty to support customized adjustments of the drug dose. While this work represents only a first step toward a quantitative tool for clinical use, the simulated treatment results indicate that the proposed mathematical model and adaptive MPC approach could serve as valuable resources to the oncologist toward creating a personalized treatment strategy that is both safe and effective. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  16. Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

    Science.gov (United States)

    Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung; Lee, Ran

    2016-01-01

    Purpose To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was 0.68±0.18 g/kg/d; according to age, the dose was 0.73±0.16 g/kg/d (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation. PMID:27738600

  17. Functional genetic polymorphisms in CYP2C19 gene in relation to cardiac side effects and treatment dose in a methadone maintenance cohort.

    Science.gov (United States)

    Wang, Sheng-Chang; Ho, Ing-Kang; Tsou, Hsiao-Hui; Liu, Sheng-Wen; Hsiao, Chin-Fu; Chen, Chia-Hui; Tan, Happy Kuy-Lok; Lin, Linen; Wu, Chi-Shin; Su, Lien-Wen; Huang, Chieh-Liang; Yang, Yi-Hong; Liu, Ming-Lun; Lin, Keh-Ming; Liu, Shu Chih; Wu, Hsiao-Yu; Kuo, Hsiang-Wei; Chen, Andrew C H; Chang, Yao-Sheng; Liu, Yu-Li

    2013-10-01

    Abstract Methadone maintenance therapy is an established treatment for heroin dependence. This study tested the influence of functional genetic polymorphisms in CYP2C19 gene encoding a CYP450 enzyme that contributes to methadone metabolism on treatment dose, plasma concentration, and side effects of methadone. Two single nucleotide polymorphisms (SNPs), rs4986893 (exon 4) and rs4244285 (exon 5), were selected and genotyped in 366 patients receiving methadone maintenance therapy in Taiwan. The steady-state plasma concentrations of both methadone and its EDDP metabolite enantiomers were measured. SNP rs4244285 allele was significantly associated with the corrected QT interval (QTc) change in the electrocardiogram (p=0.021), and the Treatment Emergent Symptom Scale (TESS) total score (p=0.021) in patients who continued using heroin, as demonstrated with a positive urine opiate test. Using the gene dose (GD) models where the CYP2C19 SNPs were clustered into poor (0 GD) versus intermediate (1 GD) and extensive (2 GD) metabolizers, we found that the extensive metabolizers required a higher dose of methadone (p=0.035), and showed a lower plasma R-methadone/methadone dose ratio (p=0.007) in urine opiate test negative patients, as well as a greater QTc change (p=0.008) and higher total scores of TESS (p=0.018) in urine opiate test positive patients, than poor metabolizers. These results in a large study sample from Taiwan suggest that the gene dose of CYP2C19 may potentially serve as an indicator for the plasma R-methadone/methadone dose ratio and cardiac side effect in patients receiving methadone maintenance therapy. Further studies of pharmacogenetic variation in methadone pharmacokinetics and pharmacodynamics are warranted in different world populations.

  18. Influence of dosing volume on the neurotoxicity of bifenthrin.

    Science.gov (United States)

    Wolansky, M J; McDaniel, K L; Moser, V C; Crofton, K M

    2007-01-01

    Pyrethroids are pesticides with high insecticidal activity and relatively low potency in mammals. The influence of dosing volume on the neurobehavioral syndrome following oral acute exposure to the Type-I pyrethroid insecticide bifenthrin in corn oil was evaluated in adult male Long Evans rats. We tested bifenthrin effects at 1 and 5 ml/kg, two commonly used dose volumes in toxicological studies. Two testing times (4 and 7 h) were used in motor activity and functional observational battery (FOB) assessments. Four to eight doses were examined at either dosing condition (up to 20 or 26 mg/kg, at 1 and 5 ml/kg, respectively). Acute oral bifenthrin exposure produced toxic signs typical of Type I pyrethroids, with dose-related increases in fine tremor, decreased motor activity and grip strength, and increased pawing, head shaking, click response, and body temperature. Bifenthrin effects on motor activity and pyrethroid-specific clinical signs were approximately 2-fold more potent at 1 ml/kg than 5 ml/kg. This difference was clearly evident at 4 h and slightly attenuated at 7 h post-dosing. Benchmark dose (BMD) modeling estimated similar 2-fold potency differences in motor activity and pyrethroid-specific FOB data. These findings demonstrate that dose volume, in studies using corn oil as the vehicle influences bifenthrin potency. Further, these data suggest that inconsistent estimates of pyrethroid potency between laboratories are at least partially due to differences in dosing volume.

  19. The influence of VKORC1 and CYP2C9 gene sequence variants on the stability of maintenance phase warfarin treatment

    DEFF Research Database (Denmark)

    Skov, Jane; Bladbjerg, Else-Marie; Leppin, Anja

    2013-01-01

    alleles require lower doses and have increased risk of overanticoagulation. METHODS: We investigated the influence of the above sequence variants on stability of maintenance phase warfarin therapy in a prospective study of 300 consecutive patients followed for one year at an anticoagulant clinic. RESULTS...... of common gene sequence variants in CYP2C9 and VKORC1 on stability of maintenance phase warfarin therapy. Patients attending an anticoagulant clinic using computer-assisted dosage were safely monitored regardless of these sequence variants, but for the small subgroup of patients with the CYP2C9 genotype *2...

  20. The Influence of Academic Culture on Quality Management System ISO 9001 Maintenance within Malaysian Universities

    Science.gov (United States)

    Basir, Siti Arni; Davies, John; Douglas, Jacqueline; Douglas, Alexander

    2017-01-01

    This study investigates the influence of the elements of academic culture on quality management system ISO 9001 maintenance within Malaysian universities. There is a dearth of empirical studies on maintaining ISO 9001, particularly in the higher education context. From the literature review, academic culture was classified according to four…

  1. Developmental Differences in the Influence of Distractors on Maintenance in Spatial Working Memory

    Science.gov (United States)

    Schutte, Anne R.; Keiser, Brian A.; Beattie, Heidi L.

    2017-01-01

    This study examined whether attention to a location plays a role in the maintenance of locations in spatial working memory in young children as it does in adults. This study was the first to investigate whether distractors presented during the delay of a spatial working-memory task influenced young children's memory responses. Across 2…

  2. ANALYSIS OF DOSE RATES DURING REPLACEMENT OF MANIPULATORS IN THE FFTF INTERIM EXAMINATION and MAINTENANCE (IEM) CELL

    International Nuclear Information System (INIS)

    NELSON, J.V.

    2002-01-01

    Replacement of a master-slave manipulator in the Interim Examination and Maintenance Cell at the Fast Flux Test Facility was carried out in August 2001. This operation created a 178-mm opening in the thick concrete wall of the hot cell. To aid in radiological work planning, dose rates outside the penetration in the wall were predicted using MCNP(trademark) photon transport calculations. The predicted dose rate was 7.7 mrem/h, which was reasonably close to the value of 10.4 mrem/h inferred from measurements

  3. Population-Level Density Dependence Influences the Origin and Maintenance of Parental Care

    OpenAIRE

    Reyes, Elijah; Thrasher, Patsy; Bonsall, Michael B.; Klug, Hope

    2016-01-01

    Parental care is a defining feature of animal breeding systems. We now know that both basic life-history characteristics and ecological factors influence the evolution of care. However, relatively little is known about how these factors interact to influence the origin and maintenance of care. Here, we expand upon previous work and explore the relationship between basic life-history characteristics (stage-specific rates of mortality and maturation) and the fitness benefits associated with the...

  4. Radon-222 related influence on ambient gamma dose.

    Science.gov (United States)

    Melintescu, A; Chambers, S D; Crawford, J; Williams, A G; Zorila, B; Galeriu, D

    2018-04-03

    Ambient gamma dose, radon, and rainfall have been monitored in southern Bucharest, Romania, from 2010 to 2016. The seasonal cycle of background ambient gamma dose peaked between July and October (100-105 nSv h -1 ), with minimum values in February (75-80 nSv h -1 ), the time of maximum snow cover. Based on 10 m a.g.l. radon concentrations, the ambient gamma dose increased by around 1 nSv h -1 for every 5 Bq m -3 increase in radon. Radon variability attributable to diurnal changes in atmospheric mixing contributed less than 15 nSv h -1 to the overall variability in ambient gamma dose, a factor of 4 more than synoptic timescale changes in air mass fetch. By contrast, precipitation-related enhancements of the ambient gamma dose were 15-80 nSv h -1 . To facilitate routine analysis, and account in part for occasional equipment failure, an automated method for identifying precipitation spikes in the ambient gamma dose was developed. Lastly, a simple model for predicting rainfall-related enhancement of the ambient gamma dose is tested against rainfall observations from events of contrasting duration and intensity. Results are also compared with those from previously published models of simple and complex formulation. Generally, the model performed very well. When simulations underestimated observations the absolute difference was typically less than the natural variability in ambient gamma dose arising from atmospheric mixing influences. Consequently, combined use of the automated event detection method and the simple model of this study could enable the ambient gamma dose "attention limit" (which indicates a potential radiological emergency) to be reduced from 200 to 400% above background to 25-50%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Neutron organ dose and the influence of adipose tissue

    Science.gov (United States)

    Simpkins, Robert Wayne

    Neutron fluence to dose conversion coefficients have been assessed considering the influences of human adipose tissue. Monte Carlo code MCNP4C was used to simulate broad parallel beam monoenergetic neutrons ranging in energy from thermal to 10 MeV. Simulated Irradiations were conducted for standard irradiation geometries. The targets were on gender specific mathematical anthropomorphic phantoms modified to approximate human adipose tissue distributions. Dosimetric analysis compared adipose tissue influence against reference anthropomorphic phantom characteristics. Adipose Male and Post-Menopausal Female Phantoms were derived introducing interstitial adipose tissue to account for 22 and 27 kg additional body mass, respectively, each demonstrating a Body Mass Index (BMI) of 30. An Adipose Female Phantom was derived introducing specific subcutaneous adipose tissue accounting for 15 kg of additional body mass demonstrating a BMI of 26. Neutron dose was shielded in the superficial tissues; giving rise to secondary photons which dominated the effective dose for Incident energies less than 100 keV. Adipose tissue impact on the effective dose was a 25% reduction at the anterior-posterior incidence ranging to a 10% increase at the lateral incidences. Organ dose impacts were more distinctive; symmetrically situated organs demonstrated a 15% reduction at the anterior-posterior Incidence ranging to a 2% increase at the lateral incidences. Abdominal or asymmetrically situated organs demonstrated a 50% reduction at the anterior-posterior incidence ranging to a 25% increase at the lateral incidences.

  6. Study of distribution of doses in maintenance operations and interventions in restricted areas of IPEN's radiopharmacy center, Brazil

    International Nuclear Information System (INIS)

    Machado, Jessica S.; Souza, Daiane C.; Rodrigues Junior, Orlando; Gerulis, Eduardo; Todo, Alberto S.

    2013-01-01

    This research was developed at the Radiopharmacy Center of the Nuclear and Energy Research Institute - IPEN/CNEN/SP, Brazil, that performs the production of radiopharmaceuticals with isotopes of the 131 I, 123 I, 201 Tl, 67 Ga, 18 F and 99 Mo for use in nuclear medicine. The radioisotopes are produced on an industrial scale and the installation was designed to meet radiation safety standards and quality control requirements. To ensure the production, there are skilled professionals who perform the tasks of maintenance of the equipment and instruments, installed in the cells of processing of radiopharmaceuticals, without which it is not possible to conduct the work with safety and quality. This study was done a survey called Survey of Variables, based on the maintenance operations and interventions in restricted areas of the Centre of Radiopharmacy and in the survey of the distribution of doses in these tasks, carried out during the period from 2005 to 2011. This research aims to identify and determine the main variables that have an impact on the worker's dose. The results are presented for the Occupationally Exposed Individual variable, variable operation, variable area/Cell, task and Feature variable and variable duration of operation, depending on the Dose variable. It is intended in this way to contribute to improvements in operations in restricted areas that may result in lower individual doses without causing significant changes in the routine of work

  7. Use of Influence Diagrams and Fuzzy Theory to Develop Assessment Method of Organizational Influences on Component Maintenance

    International Nuclear Information System (INIS)

    Yoonik Kim; Kwang-Won Ahn; Chang-Hyun Chung; Kil Yoo Kim; Joon-Eon Yang

    2002-01-01

    Organization can make influences on all the systems. Especially in case of nuclear power plants in which safety is established to be one of the most important operating goals, there have been a lot of research efforts for the hardware advancement. However in recent years, it has been widely recognized that organizational factors in nuclear power plants have an important influence on the safety attitudes and the safe behavior of individuals. Until now, any means to include assessments of organizational structure in probabilistic risk assessments have not been universally accepted. The objective of this work is to develop a method to assess organizational influences on component maintenance. Influence diagrams are introduced in this method as a decision making tool and fuzzy theory is used to reflect the vagueness in considering relevance of human activities in maintenance tasks. Introducing fuzzy theory to assess the organizational factors is deemed to a somewhat new trial, which makes it possible to convert linguistic vague descriptions into mathematical ones. Fuzzy linguistic descriptions offer an alternative and often complementary language to conventional, i.e., analytic approaches to modeling systems. Among the existing methodologies to assess organizational factors, the concept of the ω-factor model is utilized and the mechanism that organizational factors have influences on component maintenance is evaluated through composing influence diagrams. These influences go to failure rates and eventually affect component unavailability. Further study will make it possible that the influences of organizational factors on human error probabilities are incorporated into human reliability analysis and furthermore probabilistic safety assessment. (authors)

  8. Influence of random setup error on dose distribution

    International Nuclear Information System (INIS)

    Zhai Zhenyu

    2008-01-01

    Objective: To investigate the influence of random setup error on dose distribution in radiotherapy and determine the margin from ITV to PTV. Methods: A random sample approach was used to simulate the fields position in target coordinate system. Cumulative effect of random setup error was the sum of dose distributions of all individual treatment fractions. Study of 100 cumulative effects might get shift sizes of 90% dose point position. Margins from ITV to PTV caused by random setup error were chosen by 95% probability. Spearman's correlation was used to analyze the influence of each factor. Results: The average shift sizes of 90% dose point position was 0.62, 1.84, 3.13, 4.78, 6.34 and 8.03 mm if random setup error was 1,2,3,4,5 and 6 mm,respectively. Univariate analysis showed the size of margin was associated only by the size of random setup error. Conclusions: Margin of ITV to PTV is 1.2 times random setup error for head-and-neck cancer and 1.5 times for thoracic and abdominal cancer. Field size, energy and target depth, unlike random setup error, have no relation with the size of the margin. (authors)

  9. Organizational Culture Influence on Total Productive Maintenance (TPM) and Operational Performance Using RASCH Model Analysis

    OpenAIRE

    Mohd Asaad, Mohd Norhasni; Yusoff, Rushami Zien

    2013-01-01

    Abstract. Market globalization, competitive product and services, high economic crises are the most critical factors that influence the success of the manufacturing companies in global market. Therefore it is critical to the manufacturing companies to be efficient in production and lean tool may used to achieve that.  The most frequently used is the Total Preventive Maintenance (TPM), even though there are many studies have been conducted in relation to the TPM but there is limited research i...

  10. Dose management: weighing up the costs and benefits of remote maintenance

    International Nuclear Information System (INIS)

    Lefaure, C.; Lochard, J.; Blain, A.

    1989-01-01

    Reducing occupational exposure during maintenance, while at the same time preserving the economic viability of nuclear power plants, will be one of the major challenges to be faced by the industry over the next decade. Increased use of robotics is a possibility. The costs and benefits are examined in this paper. (author)

  11. Development of predictive models for estimating warfarin maintenance dose based on genetic and clinical factors.

    Science.gov (United States)

    Yang, Lu; Linder, Mark W

    2013-01-01

    In this chapter, we use calculation of estimated warfarin maintenance dosage as an example to illustrate how to develop a multiple linear regression model to quantify the relationship between several independent variables (e.g., patients' genotype information) and a dependent variable (e.g., measureable clinical outcome).

  12. Analysis on the gamma dose distribution by major corrosion products during preventive maintenance period in nuclear power plant

    International Nuclear Information System (INIS)

    Ha, Wi Ho

    2006-02-01

    The information on dose distribution inside the containment building is an essential requirement to make a reduction of radiation exposure as well as effective operation and design of nuclear power plant. After reactor shutdown, radiation exposure to workers mainly occurs during preventive maintenance period due to inspection or repair works of major components. During that period, gamma doses are induced by major corrosion products in the primary coolant system. The radiation exposure to workers has been assessed by using the measurements. The measurements are, of course, a basic and reliable assessment. But the measurement has defect such as limitation of detecting area. In order to improve the defect of the measurements, system for assessment of gamma dose distribution during preventive maintenance period by using computational code was suggested in this study. First, activity of major corrosion products was calculated by using modified CRUDSIM code. Original CRUDSIM code was modified to add evaluation of other major corrosion products besides cobalt isotopes. Modeling of containment building for YGN Unit 3 was then performed. Gamma dose distribution by major corrosion products inside the containment building was calculated by using MCNPX code. Finally, the calculations were mapped for whole space inside the containment building and were compared with the measurements. As a result of this study, the defect of the measurement are supplemented by using computational calculation system, and it is expected that workers can make an effective work plan through providing dose distribution inside the containment building in advance. In addition, this study can be applied to technology development to make an effective containment shielding design of the next generation reactor as well as an improvement of the safety for workers in nuclear power plant

  13. State of human genome at low-doses ecological influences

    International Nuclear Information System (INIS)

    Mel'nov, S.B.; Rytik, P.G.; Kruchinskij, N.G.; Kovalev, V.A.; Palamar, L.A.; Senyuk, O.F.

    2005-01-01

    The results of analysis of the state of genome (amounts of single strand breaks in DNA) of the persons exposed to influence of complex 'Chernobyl factor' in remote terms after a failure on ChNPP are resulted. Findings allowed to expose the increase of level of single strand breaks in DNA at the chronically irradiated persons mainly carry adaptive character and probably can be related to instability of genome. Thus at organism level growth of mutational pressure and strengthening of instability of cellular genome is related to the change of spectrum of biological characteristics, in particular individual reaction of somatic cells of victims on additional mutagens influences. The indicated changes can testify to existence of potential risk of remote genetic consequences of long-term irradiation influence in low doses

  14. Patient perception of methadone dose adequacy in methadone maintenance treatment: The role of perceived participation in dosage decisions.

    Science.gov (United States)

    Trujols, Joan; González-Saiz, Francisco; Manresa, María José; Alcaraz, Saul; Batlle, Francesca; Duran-Sindreu, Santiago; Pérez de Los Cobos, José

    2017-05-01

    In clinical practice, methadone maintenance treatment (MMT) entails tailoring the methadone dose to the patient's specific needs, thereby individualizing treatment. The aim of this study was to identify the independent factors that may significantly explain methadone dose adequacy from the patient's perspective. Secondary analysis of data collected in a treatment satisfaction survey carried out among a representative sample of MMT patients (n=122) from the region of La Rioja (Spain). As part of the original study protocol, participants completed a comprehensive battery to assess satisfaction with MMT, psychological distress, opinion of methadone as a medication, participation in dosage decisions, and perception of dose adequacy. Multivariate binary logistic regression showed that the only variable independently associated with the likelihood of a patient perceiving methadone dose as inadequate was the variable perceived-participation in methadone dosage decisions (OR=0.538, 95% CI=0.349-0.828). Patient participation in methadone dosage decisions was predictive of perceived adequacy of methadone dose beyond the contribution of other socio-demographic, clinical, and MMT variables. Patient participation in methadone dosage decision-making is valuable for developing a genuinely patient-centred MMT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Does body image influence the relationship between body weight and breastfeeding maintenance in new mothers?

    Science.gov (United States)

    Swanson, Vivien; Keely, Alice; Denison, Fiona C

    2017-09-01

    been studied in relation to breastfeeding maintenance. What does this study add This article examines the influence of body image on obese and healthy-weight women's breastfeeding maintenance at 6-8 weeks. Different aspects of body image mediated but did not moderate the relationship between weight status and breastfeeding maintenance, but in multivariate regression, maternal education level was the most significant predictor. Obese women had poorer body image and were less likely to maintain breastfeeding; however, for all women, body image became more negative in this postpartum period. Interventions should normalize positive aspects of women's postnatal bodies, including function rather than form. Addressing body concerns could encourage new mothers to maintain breastfeeding, irrespective of weight status. © 2017 The British Psychological Society.

  16. Efficacy and Safety of a Colistin Loading Dose, High-Dose Maintenance Regimen in Critically Ill Patients With Multidrug-Resistant Gram-Negative Pneumonia.

    Science.gov (United States)

    Elefritz, Jessica L; Bauer, Karri A; Jones, Christian; Mangino, Julie E; Porter, Kyle; Murphy, Claire V

    2017-09-01

    Emergence of multidrug-resistant (MDR) gram-negative (GN) pathogens and lack of novel antibiotics have increased the use of colistin, despite unknown optimal dosing. This study aimed to evaluate the safety and efficacy of a colistin loading dose, high-dose (LDHD) maintenance regimen in patients with MDR-GN pneumonia. A retrospective cohort analysis was performed comparing critically ill patients with MDR-GN pneumonia pre- and postimplementation of a colistin LDHD guideline with a primary outcome of clinical cure. Safety was assessed using incidence of acute kidney injury (AKI) based on RIFLE (risk, injury, failure, loss, end-stage renal disease) criteria. Seventy-two patients met the inclusion criteria (42 preimplementation and 30 postimplementation). Clinical cure was achieved in 23 (55%) patients in the preimplementation group and 20 (67%) patients in the postimplementation group ( P = .31). AKI occurred in 50% of the patients during the preimplementation period and 58% during the postimplementation period ( P = .59) with no difference in initiation rates of renal replacement therapy. The increased clinical cure rate after implementation of the colistin LDHD guideline did not reach statistical significance. The LDHD guideline, however, was not associated with an increased incidence of AKI, despite higher intravenous colistin doses. Opportunity exists to optimize colistin dosage while balancing toxicity, but larger studies are warranted.

  17. Population-Level Density Dependence Influences the Origin and Maintenance of Parental Care.

    Directory of Open Access Journals (Sweden)

    Elijah Reyes

    Full Text Available Parental care is a defining feature of animal breeding systems. We now know that both basic life-history characteristics and ecological factors influence the evolution of care. However, relatively little is known about how these factors interact to influence the origin and maintenance of care. Here, we expand upon previous work and explore the relationship between basic life-history characteristics (stage-specific rates of mortality and maturation and the fitness benefits associated with the origin and the maintenance of parental care for two broad ecological scenarios: the scenario in which egg survival is density dependent and the case in which adult survival is density dependent. Our findings suggest that high offspring need is likely critical in driving the origin, but not the maintenance, of parental care regardless of whether density dependence acts on egg or adult survival. In general, parental care is more likely to result in greater fitness benefits when baseline adult mortality is low if 1 egg survival is density dependent or 2 adult mortality is density dependent and mutant density is relatively high. When density dependence acts on egg mortality, low rates of egg maturation and high egg densities are less likely to lead to strong fitness benefits of care. However, when density dependence acts on adult mortality, high levels of egg maturation and increasing adult densities are less likely to maintain care. Juvenile survival has relatively little, if any, effect on the origin and maintenance of egg-only care. More generally, our results suggest that the evolution of parental care will be influenced by an organism's entire life history characteristics, the stage at which density dependence acts, and whether care is originating or being maintained.

  18. Population-Level Density Dependence Influences the Origin and Maintenance of Parental Care.

    Science.gov (United States)

    Reyes, Elijah; Thrasher, Patsy; Bonsall, Michael B; Klug, Hope

    2016-01-01

    Parental care is a defining feature of animal breeding systems. We now know that both basic life-history characteristics and ecological factors influence the evolution of care. However, relatively little is known about how these factors interact to influence the origin and maintenance of care. Here, we expand upon previous work and explore the relationship between basic life-history characteristics (stage-specific rates of mortality and maturation) and the fitness benefits associated with the origin and the maintenance of parental care for two broad ecological scenarios: the scenario in which egg survival is density dependent and the case in which adult survival is density dependent. Our findings suggest that high offspring need is likely critical in driving the origin, but not the maintenance, of parental care regardless of whether density dependence acts on egg or adult survival. In general, parental care is more likely to result in greater fitness benefits when baseline adult mortality is low if 1) egg survival is density dependent or 2) adult mortality is density dependent and mutant density is relatively high. When density dependence acts on egg mortality, low rates of egg maturation and high egg densities are less likely to lead to strong fitness benefits of care. However, when density dependence acts on adult mortality, high levels of egg maturation and increasing adult densities are less likely to maintain care. Juvenile survival has relatively little, if any, effect on the origin and maintenance of egg-only care. More generally, our results suggest that the evolution of parental care will be influenced by an organism's entire life history characteristics, the stage at which density dependence acts, and whether care is originating or being maintained.

  19. Organizational Culture Influence On Total Productive Maintenance (TPM and Operational Performance Using RASCH Model Analysis

    Directory of Open Access Journals (Sweden)

    Mohd Norhasni Mohd Asaad

    2014-02-01

    Full Text Available Abstract. Market globalization, competitive product and services, high economic crises are the most critical factors that influence the success of the manufacturing companies in global market. Therefore it is critical to the manufacturing companies to be efficient in production and lean tool may used to achieve that.  The most frequently used is the Total Preventive Maintenance (TPM, even though there are many studies have been conducted in relation to the TPM but there is limited research in investigating the effects of the TPM on operational performance. However, the result of the studies was not consistent, where TPM practice may have positive and negative impact on operational performance. Among the reason is the culture of the organization that influenced the implementation of TPM and operational performance. Due to that this study attempts to investigate the influence of organizational culture on the TPM implementation and operational performance.  Rasch model is used in this study due to its ability in interpreting and analyzing the ability of respondents in performing the difficult items. The online questionnaires were distributed to 63 randomly selected automotive companies located at Northern Region of Malaysia.  Results of the study revealed that the organizational culture has influenced on the successful implementation of TPM and operational performance. Therefore by the implementation of TPM in outstanding organizational culture can improve operational performance.   Keyword: Total Preventive Maintenance (TPM, Lean manufacturing, Operational performance, Organizational culture, Rasch modeldoi:10.12695/ajtm.2013.6.2.2How to cite this article:Mohd Asaad, M.N and Yusoff, R.Z. (2013. Organizational Culture Influence On Total Productive Maintenance (TPM and Operational Performance Using RASCH Model Analysis . The Asian Journal of Technology Management 6 (2: 72-81. Print ISSN: 1978-6956; Online ISSN: 2089-791X.  doi:10.12695/ajtm

  20. External exposure dose of car mechanics during the maintenance of the cars from the risk cautionary area

    International Nuclear Information System (INIS)

    Kawakami, Hiroto; Yamada, Norikazu; Sasaki, Satoru; Kawasaki, Satoru

    2011-12-01

    At the request of the Local Nuclear Emergency Response Headquarters, JNES has estimated the effective external exposure dose of car mechanics during the maintenance of the cars from the risk cautionary area. JNES investigated the contamination of the cars from the risk cautionary area and of the average cars at Fukushima city cooperated by the Japan Automobile Dealers Association. Data of screed cars by the Local Nuclear Emergency Response Headquarters is also considered in. Effective external exposure dose of car mechanics treating the cars screened with the emergency situation screening level is estimated to be less than 1 mSv/y under the conservative conditions. This result shows that particular health concern isn't necessary for them. (author)

  1. Factors influencing botulinum toxin dose instability in spasmodic dysphonia patients.

    Science.gov (United States)

    Rosow, David E; Pechman, Amanda; Saint-Victor, Sandra; Lo, Kaming; Lundy, Donna S; Casiano, Roy R

    2015-05-01

    Many patients with spasmodic dysphonia (SD) see consistent effects from botulinum toxin (BTX) injections of the same dose, whereas others require dosage changes over time. We sought to determine whether demographics (age and gender) or environmental factors (smoking) affect the long-term stability of BTX dosing in these patients. Retrospective review. Charts of all patients undergoing BTX injection for adductor SD were reviewed. Dosage change, defined as whether there was any difference in total dosage used between two beneficial injections, was used as a measure of dosing stability. Beneficial injections were indicated by a voice rating score of at least three of four and any non-zero duration of improved voice. Logistic regression analysis was performed to determine whether age, gender, smoking status, or duration of treatment correlated with odds of having a dosage change. A total of 211 patients were ultimately included. Age, gender, and smoking status were all found to have no correlative effect on dosing stability. The only factor that was predictive of dose stability was the number of previous beneficial injections, as every additional injection led to decreased odds of a change in dosage for the next injection (odds ratio=0.964; 95% confidence interval=0.947-0.981). Dosage of BTX injections for long-term treatment of SD has a significant propensity to remain stable over time. Factors such as age, gender, and smoking status do not appear to influence the dosage stability. These findings should allow for better patient counseling regarding expectations for their long-term treatment. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Dose rate in the reactor room and environment during maintenance in fusion reactors

    International Nuclear Information System (INIS)

    Maki, Koichi; Satoh, Satoshi; Takatsu, Hideyuki; Seki, Yasushi

    1995-01-01

    According to the International Thermonuclear Experimental Reactor (ITER) conceptual design activity, after reactor shutdown, damaged segments are pulled up from the reactor and hung from the reactor room ceiling by a remote handling device. The dose rate in the reactor room and the environment is estimated for this situation, and the following results are obtained. First, the dose rate in the room is > 10 8 μSv/h. Since this dose rate is 10 7 times greater than the biological radiation shielding design limit of 25 μSv/h, workers cannot enter the room. Second, lenses and optical fiber composed of glass that is radiation resistant up to 10 6 Gy would be damaged after <100 h near the segment, and devices using semiconductors could not work after several hours or so in the aforementioned dose-rate conditions. Third, during suspension of one blanket segment from the ceiling, the dose rate in the site boundary can be reduced by one order by a 23-cm-thicker reactor building roof. To reduce dose rate in public exposure to a value that is less than one-tenth of the public exposure radiation shielding design limit of 100 μSv/yr, the distance of the site boundary from the reactor must be greater than 200 m for a reactor building with a 160-cm-thick concrete roof. 9 refs., 6 figs., 2 tabs

  3. Lung doses from radon in dwellings and influencing factors

    International Nuclear Information System (INIS)

    Stranden, E.

    1980-01-01

    The radon concentration in Norwegian dwellings and the lung doses received by the Norwegian population are reported. The biological effects of these doses are discussed. The mean value of radon-daughters in Norwegian dwellings was found to be about 7x10 -3 WL (working levels). This corresponds to an annual exposure of about 0.3 WLM (working level months). From studies of the lung cancer statistics of Norway, this exposure may account for about 10% of the annual lung cancer cases in Norway. The variations in the radon concentration inside dwellings are discussed, and the influence of exhalation, ventilation and meteorological parameters upon the respiratory dosage is studied. From the risk estimates performed, the consequences of an increased indoor radon concentration due to reduced ventilation or introduction of building materials with high radium concentrations are discussed. From comparison of the population doses from different sources of radiation, it is evident that a possible future increase in the radon concentration in dwellings is one of the most serious radiation protection problems of our time. (author)

  4. Competitive Position of Dependent Passenger Car Maintenance Companies – Influences, Developments and Challenges in the German Market

    Directory of Open Access Journals (Sweden)

    Werdich Karl

    2015-06-01

    Full Text Available The presented paper concerns itself with passenger car maintenance companies and their competitiveness. Internal and external influences, change drivers and general changes in the companies and their organisation were identified and analysed. The influence of the development of technology and the diffusion of innovations are highlighted in particular. Under consideration of the competitiveness factors, current and future challenges for the passenger car maintenance companies were worked out. Based on these analyses, future tasks, problem statements and challenges were compiled for passenger car maintenance companies from which other subjects of scientific investigation in area of strategic and economic importance arose.

  5. Salmeterol/fluticasone stable-dose treatment compared with formoterol/budesonide adjustable maintenance dosing: impact on health-related quality of life

    Directory of Open Access Journals (Sweden)

    Williams Angela E

    2007-07-01

    Full Text Available Abstract Background Improving patients' health-related quality of life (HRQoL is recognized as a fundamental part of asthma management. The aims of this study were to evaluate the long-term efficacy (including symptom-free days and exacerbations and impact on HRQoL of a stable-dose regimen of salmeterol/fluticasone propionate (SAL/FP and an adjustable maintenance dosing (AMD regimen of formoterol/budesonide (FOR/BUD where treatment is adjusted based on symptoms [SAM40056]. Methods A total of 688 outpatients with asthma receiving regular low-dose inhaled corticosteroids (ICS plus a long-acting β2-agonist, or medium dose ICS alone participated in this randomized, double-blind, double-dummy, parallel-group, 1-year trial, which was conducted in 91 centers in 15 countries. Patients were randomized to receive 1 inhalation of SAL/FP 50/250 μg BID or 2 inhalations of FOR/BUD 6/200 μg BID during Weeks 1–4. For Weeks 5–52, patients meeting strict continuation criteria for stable asthma at Week 4 received AMD with FOR/BUD or stable-dose SAL/FP. Results The percentage of symptom-free days was significantly greater (58.8% vs 52.1%; p = 0.034 and the annual exacerbation rate was significantly lower (47%; p = 0.008 with stable-dose SAL/FP compared with FOR/BUD AMD. A total of 568 patients completed the Asthma Quality of Life Questionnaire (AQLQ at least once during the study. The mean change from baseline in AQLQ overall score was numerically greater with SAL/FP than FOR/BUD at week 28 and week 52, but did not reach statistical significance (p = 0.121 at Week 52. However, in a post hoc logistic regression analyses for any AQLQ improvement, significant benefits with SAL/FP were seen at both time points (p = 0.038 and p = 0.009, respectively. The minimally important difference of ≥ 0.5-point improvement in AQLQ overall score was achieved by a significantly greater number of patients receiving SAL/FP at Week 28 (68% vs 60%; p = 0.049; a trend for this

  6. The influence of stakeholder groups in operation and maintenance services of offshore wind farms

    DEFF Research Database (Denmark)

    Ahsan, Dewan; Pedersen, Søren

    2018-01-01

    One of the prime challenges in offshore wind is to manage and coordinate with the various stakeholders involved in the operation and maintenance (O&M) phase. Therefore the aims of this paper are: i) to map the stakeholder groups involved in O&M of Offshore Wind Farm (OWF), ii) to assess...... the identified stakeholder group's interest and power to influence O&M, iii) to evaluate the relationship between different stakeholder groups and iv) to highlight potential strategies to manage the stakeholder groups. In this article, the stakeholder analysis approach is used. The results reveal that eleven key...

  7. Influence of radioactive contaminants on absorbed dose estimates for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Watson, E.E.; Stabin, M.G.

    1986-01-01

    Several popular radiopharmaceutical products contain low levels of radioactive contaminants. These contaminants increase the radiation absorbed dose to the patient without any increased benefit and, in some cases, with a decrease in image quality. The importance of a contaminant to the radiation dosimetry picture is a function of 1) the contaminant level, 2) the physical half-life of the contaminant, 3) the organ uptake and the biological half-time of the contaminant in the various body systems, and 4) the decay mode, energy, etc. of the contaminant. The general influence of these parameters is discussed in this paper; families of curves are included that reflect the changing importance of contaminant dosimetry with respect to the primary radionuclide as a function of these variables. Several specific examples are also given of currently used radiopharmaceutical products which can contain radioactive contaminants (I-123, In-111, Tl-201, Ir-191m, Rb-82, Au-195m). 7 references, 8 figures, 4 tables

  8. Recommendations to designers aimed at minimizing radiation dose incurred in operation, maintenance, inspection and repair of light-water reactors

    International Nuclear Information System (INIS)

    1978-01-01

    In the framework of the exchange of experience between nuclear power plant operators organized by the services of the Commission of the European Communities an ad-hoc working party elaborated recommendations particularly directed to those concerned with design of light water reactor plants. The necessary design measures which should be followed to minimize radiation dose incurred in operation, maintenance, inspection and repair of such reactors are listed. The recommendations are based on recent views expressed by operating utilities within the Community. It is intended to revise these recommendations at suitable intervals in order to make use of the most recent experience and to keep the report up to date with the actual state of art in nuclear technology

  9. Full system decontamination for dose reduction at the preventive maintenance work of the reactor core internals

    International Nuclear Information System (INIS)

    Sato, Y.; Inami, I.; Suzuki, N.; Fujimori, A.; Wille, H.

    2000-01-01

    At the Fukushima Dai-ichi Nuclear Power Station unit 3 and unit 2 of Tokyo Electric Power Company (TEPCO), the replacement of the core shroud and internals have been conducted respectively in the FY 1997 outage and in the FY 1998 outage. The replacement of the welded core internals in operating BWR plants is the first time in the world as complete countermeasure to improve SCC resistance. At present both units are operating smoothly. The developed technology concept is to restore those internals in air inside the reactor pressure vessel. To reduce the radiation dose rate inside the RPV, not only a shielding method was applied to cut the radiation from the irradiated structures but also a chemical decontamination method was applied to dissolve the radioactive crud deposit on the surface by using chemical agents. The CORD UV process was applied for this Full System Decontamination including operating the reactor recirculation pumps. The critical pass time required was approximately 7 days for each unit. In both units the radioactivity of 10 TBq (280 Ci) and the Fe, Ni, Cr crud of 60-70 kg as metal in total was dissolved and removed by 5 m 3 (175 ft 3 ) ion exchange resins as only waste generated. The obtained decontamination factor (DF) at the RPV bottom reached 40-100. As result, the dose rate decreased to approximately 0.1 mSv/h under water. Before and after the installation of the in-vessel shielding, a mechanical cleaning was extensively applied inside the RPV to remove the residual crud as well as the cutting particles. As result, the RPV bottom dose rate decreased further to 0.03 mSv/h under water and 0.2 mSv/h in air. A better working environment for human access than expected was established inside the RPV, resulting the 70, 140 man*Sv saving respectively at unit 3 (1F-3) and unit 2 (1F-2). (author)

  10. Buprenorphine Maintenance Subjects Are Hyperalgesic and Have No Antinociceptive Response to a Very High Morphine Dose.

    Science.gov (United States)

    Athanasos, Peter; Ling, Walter; Bochner, Felix; White, Jason M; Somogyi, Andrew A

    2018-03-05

    Acute pain management in opioid-dependent persons is complicated because of tolerance and opioid-induced hyperalgesia. Very high doses of morphine are ineffective in overcoming opioid-induced hyperalgesia and providing antinociception to methadone-maintained patients in an experimental setting. Whether the same occurs in buprenorphine-maintained subjects is unknown. Randomized double-blind placebo-controlled. Subjects were tested on two occasions, at least five days apart, once with intravenous morphine and once with intravenous saline. Subjects were tested at about the time of putative trough plasma buprenorphine concentrations. Ambulatory. Twelve buprenorphine-maintained subjects: once daily sublingual dose (range = 2-22 mg); no dose change for 1.5-12 months. Ten healthy controls. Intravenous morphine bolus and infusions administered over two hours to achieve two separate pseudo-steady-state plasma concentrations one hour apart. Pain tolerance was assessed by application of nociceptive stimuli (cold pressor [seconds] and electrical stimulation [volts]). Ten blood samples were collected for assay of plasma morphine, buprenorphine, and norbuprenorphine concentrations until three hours after the end of the last infusion; pain tolerance and respiration rate were measured to coincide with blood sampling times. Cold pressor responses (seconds): baseline: control 34 ± 6 vs buprenorphine 17 ± 2 (P = 0.009); morphine infusion-end: control 52 ± 11(P = 0.04), buprenorphine 17 ± 2 (P > 0.5); electrical stimulation responses (volts): baseline: control 65 ± 6 vs buprenorphine 53 ± 5 (P = 0.13); infusion-end: control 74 ± 5 (P = 0.007), buprenorphine 53 ± 5 (P > 0.98). Respiratory rate (breaths per minute): baseline: control 17 vs buprenorphine 14 (P = 0.03); infusion-end: control 15 (P = 0.09), buprenorphine 12 (P < 0.01). Infusion-end plasma morphine concentrations (ng/mL): control 23 ± 1

  11. Renewal and maintenance of a nuclear structure data file used for the calculations of dose conversion factors

    International Nuclear Information System (INIS)

    Togawa, Orihiko; Yamaguchi, Yukichi

    1996-02-01

    The ENSDF decay data are used as fundamental data to compute radiation data in the DOSDAC code system, which was developed at JAERI, for the calculation of dose conversion factors. The ENSDF decay data have been periodically revised by reviewing new experimental data in the literature under an international network. The use of this data file enables us to calculate radiation data from information which is the newest and internationally recognized. In spite of this advantage, the decay data file is seldom used in applied fields. This is due to some problems to be solved from a viewpoint of the calculation of radiation data, as well as its complicated structure. This report describes methods for renewal and maintenance of the ENSDF decay data used for the calculation of dose conversion factors. In case that the decay data are used directly, attention should be sometimes paid to some problems, for example defects in data. In renewing and using the ENSDF decay data, the DOSDAC code system tries to avoid wrong calculations of radiation data by check and modification of defects in data through four supporting computer codes. (author)

  12. Comparative influence of dose rate and radiation nature, on lethality after big mammals irradiation

    International Nuclear Information System (INIS)

    Destombe, C.; Le Fleche, Ph.; Grasseau, A.; Reynal, A.

    1997-01-01

    For the same dose and the 30 days lethality as biological criterion, the dose rate influence is more important than the radiation nature on the results of an big mammals total body irradiation. (authors)

  13. The Influence of Dosing Modes of Coagulate on Arsenic Removal

    Directory of Open Access Journals (Sweden)

    Zhibin Zhang

    2014-01-01

    Full Text Available Three different dosing modes, including one single dosing mode and two sequential dosing modes, were applied in high-arsenic contaminated water treatment. The results illustrated that the As (V soluble and the As (V nonspecifically sorbed were the insignificant species from Fe-As (V samples in the sequential dosing mode, while they were higher in the single dosing mode. However, it could be further concluded that the mobility of the Fe-As (V in sequential dosing mode was greater than that in single dosing mode. Besides, the main arsenic speciation governing the arsenic-borne coagulates was the As (V associated with poorly crystalline hydrous oxides of Fe in sequential or single dosing mode. Moreover, the particle size distribution analysis indicated that the sequential dosing mode was more prevalent in neutralizing and adsorbing the As (V compared with the single dosing mode. In the FT-IR spectra, the presence of arsenic was highlighted by a well resolved band at 825–829 cm−1. The positions of the As–O stretching vibration bands were shifted gradually as the dosing mode changed from the single to the sequential. This result could be related to the distribution of arsenic speciation in different dosing modes.

  14. Influence of dose distribution homogeneity on the tumor control probability in heavy-ion radiotherapy

    International Nuclear Information System (INIS)

    Wen Xiaoqiong; Li Qiang; Zhou Guangming; Li Wenjian; Wei Zengquan

    2001-01-01

    In order to estimate the influence of the un-uniform dose distribution on the clinical treatment result, the Influence of dose distribution homogeneity on the tumor control probability was investigated. Basing on the formula deduced previously for survival fraction of cells irradiated by the un-uniform heavy-ion irradiation field and the theory of tumor control probability, the tumor control probability was calculated for a tumor mode exposed to different dose distribution homogeneity. The results show that the tumor control probability responding to the same total dose will decrease if the dose distribution homogeneity gets worse. In clinical treatment, the dose distribution homogeneity should be better than 95%

  15. Patient positioning and its influence on dose distribution

    International Nuclear Information System (INIS)

    Morrissey, J.; Moss, R.; Watkins, P.

    2000-01-01

    In comparison to conventional radiotherapy, the positioning of a patient for BNCT treatment has some unique aspects. In particular, the neutron beam coming from the core of a nuclear research reactor is fixed and horizontal. In particular, a head fixation mask, which is prepared at the patient referral hospital, is included in the CT images. The mask allows reproducible positioning for use during the treatment. Fiducial markers placed on the mask before imaging, provide reference points. The INEEL treatment planning code used in Petten produces a beam angle, and beam line entrance and exit co-ordinates. These are related to the fiducial marker co-ordinates. A spreadsheet, named COSINE, developed at Petten produces positioning co-ordinates from the data produced by the rtt MC code. These co-ordinates are related to a positioning frame, which allows the marking of the beams on the mask. In order to have reliable treatment data, the influence of small deviations of angle or target point on dose distribution must be known. To demonstrate this, a number of beams have been calculated with the Petten beam, with slight variations and compared with an approved plan. (author)

  16. Influence of Different Implant Geometry in Clinical Longevity and Maintenance of Marginal Bone: A Systematic Review.

    Science.gov (United States)

    Lovatto, Sabrina Telles; Bassani, Rafaela; Sarkis-Onofre, Rafael; Dos Santos, Mateus Bertolini Fernandes

    2018-03-26

    To assess, through a systematic review, the influence of different implant geometries on clinical longevity and maintenance of marginal bone tissue. An electronic search was conducted in MEDLINE, Scopus, and Web of Science databases, limited to studies written in English from 1996 to 2017 using specific search strategies. Only randomized controlled trials (RCTs) that compared dental implants and their geometries were included. Two reviewers independently selected studies, extracted data, and assessed the risk of bias of included studies. From the 4006 references identified by the search, 24 were considered eligible for full-text analysis, after which 10 studies were included in this review. A similar behavior of marginal bone loss between tapered and cylindrical geometries was observed; however, implants that had micro-threads in the neck presented a slight decrease of marginal bone loss compared to implants with straight or smooth neck. Success and survival rates were high, with cylindrical implants presenting higher success and survival rates than tapered ones. Implant geometry seems to have little influence on marginal bone loss (MBL) and survival and success rates after 1 year of implant placement; however, the evidence in this systematic review was classified as very low due to limitations such as study design, sample size, and publication bias. Thus, more well-designed RCTs should be conducted to provide evidence regarding the influence of implant geometry on MBL and survival and success rates after 1 year of implant placement. © 2018 by the American College of Prosthodontists.

  17. Influence of radiation dose and dose-rate on modification of barley seed radiosensitivity by post-treatment with caffeine

    International Nuclear Information System (INIS)

    Sharma, G.J.

    1987-01-01

    Influence of radiation doses (100, 150 and 200 Gy) and dose-rates (1.27-0.023 Gy/Sec) on the modification of oxic and anoxic radiation damage by caffeine at different concentrations has been investigated using metabolizing barley seeds as test system. As the radiation dose increases from 100 to 200 Gy, the magnitude of oxic and anoxic damages increase at all the dose-rates. Caffeine is able to afford partial radioprotection against the oxic damage, at the same time potentiating the anoxic damage. However, caffeine effect against the oxic and anoxic components of damage depend largely upon the dose of radiation applied and also on the dose-rate used. The possible mechanism of action of caffeine in bringing about the differential modification of oxic and anoxic damages has been discussed. 19 refs., 2 tables. (author)

  18. QT response after a test dose and during maintenance therapy with AZD1305 in patients with atrial fibrillation: a double-blind, randomized, placebo-controlled trial

    DEFF Research Database (Denmark)

    Egstrup, Kenneth; Bergfeldt, Lennart; Duris, Tibor

    2011-01-01

    AZD1305 is an investigational antiarrhythmic agent that prolongs refractoriness through combined potassium and sodium channel inhibition. This study aimed to explore the utility of a test dose in predicting QT interval corrected according to Fridericia's formula (QTcF) during subsequent maintenance...

  19. Dose-related difference in progression rates of cytomegalovirus retinopathy during foscarnet maintenance therapy. AIDS Clinical Trials Group Protocol 915 Team.

    Science.gov (United States)

    Holland, G N; Levinson, R D; Jacobson, M A

    1995-05-01

    A previous dose-ranging study of foscarnet maintenance therapy for cytomegalovirus retinopathy showed a positive relationship between dose and survival but could not confirm a relationship between dose and time to first progression. This retrospective analysis of data from that study was undertaken to determine whether there was a relationship between dose and progression rates, which reflects the amount of retina destroyed when progression occurs. Patients were randomly given one of two foscarnet maintenance therapy doses (90 mg/kg of body weight/day [FOS-90 group] or 120 mg/kg of body weight/day [FOS-120 group] after induction therapy. Using baseline and follow-up photographs and pre-established definitions and methodology in a masked analysis, posterior progression rates and foveal proximity rates for individual lesions, selected by prospectively defined criteria, were calculated in each patient. Rates were compared between groups. The following median rates were greater for the FOS-90 group (N = 8) than for the FOS-120 group (N = 10): greatest maximum rate at which lesions enlarged in a posterior direction (43.5 vs 12.5 microns/day; P = .002); posterior progression rate for lesions closest to the fovea (42.8 vs 5.5 microns/day; P = .010); and maximum foveal proximity rate for either eye (32.3 vs 3.4 microns/day; P = .031). Patients receiving higher doses of foscarnet have slower rates of progression and therefore less retinal tissue damage during maintenance therapy. A foscarnet maintenance therapy dose of 120 mg/kg of body weight/day instead of 90 mg/kg of body weight/day may help to preserve vision in patients with cytomegalovirus retinopathy.

  20. Radiation doses in pediatric radiology: influence of regulations and standards

    International Nuclear Information System (INIS)

    Suleiman, O.H.

    2004-01-01

    The benefits of X-ray examinations contribute to the quality of modern medicine; however the risk of using X-rays, a carcinogen, has always been a concern. This concern is heightened for pediatric patients, who have a much greater sensitivity to the carcinogenic effects of radiation than adults. The principle of as low as reasonably achievable, or ALARA, is essential for minimizing the radiation dose patients receive, especially for pediatric patients. In order to keep radiation doses ALARA, one must know the dose patients receive. The determination of radiation dose in a standard way is therefore necessary so that these doses can be compared with practice, and for meaningful comparison against voluntary standards. In extreme situations, where public health needs may require mandatory standards, or regulations, the quantitative measurement and calculation of radiation dose becomes essential. How some radiation dose metrics and standards have evolved, including the value of different metrics such as entrance air kerma, organ dose, and effective dose will be presented. Recent pediatric X-ray studies, whether or not dedicated pediatric equipment is necessary, and recent initiatives by the Food and Drug Administration for pediatric population will be discussed. (orig.)

  1. Prediction of warfarin maintenance dose in Han Chinese patients using a mechanistic model based on genetic and non-genetic factors.

    Science.gov (United States)

    Lu, Yuan; Yang, Jinbo; Zhang, Haiyan; Yang, Jin

    2013-07-01

    Many attempts have been made to predict the warfarin maintenance dose in patients beginning warfarin therapy using a descriptive model based on multiple linear regression. Here we report the first attempt to develop a comprehensive mechanistic model integrating in vitro-in vivo extrapolation (IVIVE) with a pharmacokinetic-pharmacodynamic model to predict the warfarin maintenance dose in Han Chinese patients. The model incorporates demographic factors [sex, age, body weight (BW)] and the genetic polymorphisms of cytochrome P450 (CYP) 2C9 (CYP2C9) and vitamin K epoxide reductase complex subunit 1 (VKORC1). Information on the various factors, mean warfarin daily dose and International Normalized Ratio (INR) was available for a cohort of 197 Han Chinese patients. Based on in vitro enzyme kinetic parameters for S-warfarin metabolism, demographic data for Han Chinese and some scaling factors, the S-warfarin clearance (CL) was predicted for patients in the cohort with different CYP2C9 genotypes using IVIVE. The plasma concentration of S-warfarin after a single oral dose was simulated using a one-compartment pharmacokinetic model with first-order absorption and a lag time and was combined with a mechanistic coagulation model to simulate the INR response. The warfarin maintenance dose was then predicted based on the demographic data and genotypes of CYP2C9 and VKORC1 for each patient and using the observed steady-state INR (INRss) as a target value. Finally, sensitivity analysis was carried out to determine which factor(s) affect the warfarin maintenance dose most strongly. The predictive performance of this mechanistic model is not inferior to that of our previous descriptive model. There were significant differences in the mean warfarin daily dose in patients with different CYP2C9 and VKORC1 genotypes. Using IVIVE, the predicted mean CL of S-warfarin for patients with CYP2C9*1/*3 (0.092 l/h, n = 11) was 57 % less than for those with wild-type *1/*1 (0.215 l/h, n

  2. Two factors influencing dose reconstruction in low dose range: the variability of BKG intensity on one individual and water content

    International Nuclear Information System (INIS)

    Zhang, Tengda; Zhang, Wenyi; Zhao, Zhixin; Zhang, Haiying; Ruan, Shuzhou; Jiao, Ling

    2016-01-01

    A fast and accurate retrospective dosimetry method for the triage is very important in radiation accidents. Electron paramagnetic resonance (EPR) fingernail dosimetry is a promising way to estimate radiation dose. This article presents two factors influencing dose reconstruction in low dose range: the variability of background signal (BKG) intensity on one individual and water content. Comparing the EPR spectrum of dried and humidified fingernail samples, it is necessary to add a procedure of dehydration before EPR measurements, so as to eliminate the deviation caused by water content. Besides, the BKGs of different fingers' nails are not the same as researchers thought previously, and the difference between maximum and minimum BKG intensities of one individual can reach 55.89 %. Meanwhile, the variability of the BKG intensity among individuals is large enough to impact precise dose reconstruction. Water within fingernails and instability of BKG are two reasons that cause the inaccuracy of radiation dose reconstruction in low-dosage level. (authors)

  3. Maintenance Management Update.

    Science.gov (United States)

    Sternloff, Robert E.

    1987-01-01

    Current trends in park maintenance are overviewed, including maintenance impact statements, avoidance of cost through efficient use and national resource conservation, horticultural accomplishments that influence maintenance management, and vandalism prevention. (CB)

  4. Buprenorphine/Naloxone Maintenance Therapy: an Observational Retrospective Report on the Effect of Dose on 18 months Retention in an Office-Based Treatment Program

    Directory of Open Access Journals (Sweden)

    Theodore V Parran

    2017-10-01

    Full Text Available Context and objective: Buprenorphine has been available with few reports of the dose range necessary to adequately maintain patients. We report on the effect of 8 mg/d versus 16 mg/d of buprenorphine on long-term patient retention in office-based opioid maintenance (OBOMT. Design, setting, and participants: Case series, at an urban hospital-based primary care clinic providing OBOMT to 157 opiate-dependent, low socioeconomic status, uninsured, nonhomeless patients. Intervention: The OBOMT program operated by a comprehensive sobriety treatment program experienced State funding cuts. Thus, after 2 years, the program was required by the State funder to decrease the buprenorphine maintenance dose from 16 to 8 mg/d for all new admissions. We report on patient retention before and after dose reduction. Main outcome measures: The primary outcomes of this study were to measure and compare patient retention in the 2 cohorts at each point of treatment transition over the 18 months following OBOMT initiation. Results: No significant differences in patient retention were observed between the 16 and 8 mg/d patient cohorts. Lower dose buprenorphine maintenance (8 mg/d in uninsured patients enrolled in publicly funded long-term OBOMT combined with comprehensive sobriety counseling was as effective as higher dose therapy (16 mg/d in promoting patient retention throughout the study period. This lower dose resulted in a substantial saving to the public funding agency. Conclusions: In an observational retrospective report, retention in treatment of opiate-addicted patients was the same at 8 and 16 mg/d buprenorphine doses after 18 months. These data have implications for public and managed care funding of OBOMT, for the general prescribing of buprenorphine in outpatient care, and may be instructive in the ongoing debate about the relationship between buprenorphine dose.

  5. Influence of intravenous opioid dose on postoperative ileus.

    Science.gov (United States)

    Barletta, Jeffrey F; Asgeirsson, Theodor; Senagore, Anthony J

    2011-07-01

    Intravenous opioids represent a major component in the pathophysiology of postoperative ileus (POI). However, the most appropriate measure and threshold to quantify the association between opioid dose (eg, average daily, cumulative, maximum daily) and POI remains unknown. To evaluate the relationship between opioid dose, POI, and length of stay (LOS) and identify the opioid measure that was most strongly associated with POI. Consecutive patients admitted to a community teaching hospital who underwent elective colorectal surgery by any technique with an enhanced-recovery protocol postoperatively were retrospectively identified. Patients were excluded if they received epidural analgesia, developed a major intraabdominal complication or medical complication, or had a prolonged workup prior to surgery. Intravenous opioid doses were quantified and converted to hydromorphone equivalents. Classification and regression tree (CART) analysis was used to determine the dosing threshold for the opioid measure most associated with POI and define high versus low use of opioids. Risk factors for POI and prolonged LOS were determined through multivariate analysis. The incidence of POI in 279 patients was 8.6%. CART analysis identified a maximum daily intravenous hydromorphone dose of 2 mg or more as the opioid measure most associated with POI. Multivariate analysis revealed maximum daily hydromorphone dose of 2 mg or more (p = 0.034), open surgical technique (p = 0.045), and days of intravenous narcotic therapy (p = 0.003) as significant risk factors for POI. Variables associated with increased LOS were POI (p POI and prolonged LOS, particularly when the maximum hydromorphone dose per day exceeds 2 mg. Clinicians should consider alternative, nonopioid-based pain management options when this occurs.

  6. The influence of dose per fraction on repair kinetics

    International Nuclear Information System (INIS)

    Rojas, A.; Joiner, M.C.

    1989-01-01

    The use of multiple fractions per day (MFD) in radiotherapy requires information about the rate of repair of radiation injury. It is important to know the minimum interval between fractions necessary for maximum sparing of normal tissue damage, whether rate of repair is dependent on the size of dose per fraction and if it is different in early and late responding tissues and in tumours. To address these questions, the rate of repair between radiation dose fractions was measured in mouse skin (acute damage), mouse kidney (late damage) and a mouse tumour (carcinoma NT). Skin and kidney measurements were made using multiple split doses of X-rays, followed by a neutron top-up. For skin, faster recovery was obtained with 4.4 Gy fractions (t1/2 = 3.46 ± 0.88 h). In contrast kidney showed slower recovery at a low dose per fraction of 2 Gy (t1/2 = 1.69 ± 0.39 h) than at a higher dose of 7 Gy per fraction (t1/2 = 0.92 ± 0.1h). These data show that repair rate is dependent on the size of dose per fraction, but not in a simple way. T1/2 values now available for many different tissues generally lie in the range of 1-2h, and are not correlated with proliferation status or early versus late response to treatment. At the doses used currently in clinical MFD treatments, these data indicate that damage in almost all normal tissues would increase if interfraction intervals less than 6 h were used. The t1/2 for CaNT (0.31 ± 0.15 h) is less than for any normal tissue. This underlines that the excess morbidity resulting from interfraction intervals < 6 h will not be paralleled by an increased effect in tumours. (author). 25 refs.; 7 figs

  7. The influence of dose fractionation and dose rate on normal tissue responses

    International Nuclear Information System (INIS)

    Barendsen, G.W.

    1982-01-01

    An analysis of responses of a variety of normal tissues in animals to fractionated irradiations has been made with the aim of developing a formalism for the prediction of tolerance doses as a function of the dose per fraction and the overall treatment time. An important feature of the formalism is that it is directly based on radiological insights and therefore provides a logical concept to account for the diversity of tissue responses. (Auth.)

  8. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  9. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  10. Influence of dose and its distribution in time on dose-response relationships for low-LET radiation

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This book examines the influence of dose rate and magnitude on the genetic and carcinogenic effects of radiation exposure in animals and man. It systematically examines a broad range of biological effects in simple systems, plants, laboratory animals, and man with special attention given to the effects of prenatal irradiation, changes in life span, and tumorigenesis. An enormous volume of data is provided about human tumorigenesis and the data and shortcomings are summarized. There is an extended general discussion of the consideration in quantitative dose and dose rate relationships and of the limitations of the data and analyses which have led to a linear interpolation of risk at low doses and dose rates. An argument is made for dose rate dependence in tumorigenesis as being consistent with all other radiation effects and for the applicability of Dose Rate Effectiveness Factors (DREF) in providing a more realistic assessment of the risk of radiation carcinogenesis. The report is documented with 24 pages of references. There are numerous graphs and tables, all clear and to the point. This book is a superb review and summary of the data on radiation risks

  11. Maintenance therapy of childhood acute lymphoblastic leukemia revisited—Should drug doses be adjusted by white blood cell, neutrophil, or lymphocyte counts?

    DEFF Research Database (Denmark)

    Schmiegelow, Kjeld; Nersting, Jacob; Nielsen, Stine Nygaard

    2016-01-01

    BACKGROUND: 6-Mercaptopurine (6MP) and methotrexate (MTX) based maintenance therapy is a critical phase of childhood acute lymphoblastic leukemia treatment. Wide interindividual variations in drug disposition warrant frequent doses adjustments, but there is a lack of international consensus on dose...... levels of 6-thioguanine nucleotides or MTX (including its polyglutamates) to be significant relapse predictors. The parameters significantly associated with risk of relapse (N = 83) were male sex (hazard ratio [HR] 2.0 [1.3-3.1], P = 0.003), WBC at diagnosis (HR = 1.04 per 10 × 10(9) /l rise [1...

  12. A COMPARISON OF TWO DIFFERENT DOSES OF DEXMEDETOMIDINE INFUSION DURING MAINTENANCE OF GENERAL ANAESTHESIA IN PATIENTS UNDERGOING SPINE SURGERIES, FUNCTIONAL ENDOSCOPIC SINUS SURGERY AND MIDDLE EAR SURGERIES

    Directory of Open Access Journals (Sweden)

    Bijay

    2016-03-01

    Full Text Available BACKGROUND This study is undertaken to compare the hemodynamic effects and reduction in the doses of volatile anaesthetics and muscle relaxants using two different doses of dexmedetomidine infusion during maintenance of anaesthesia in spine, functional endoscopic sinus surgery and middle ear surgeries. METHODS Sixty patients are randomly divided into 2 groups of 30 each. After shifting to the operation theatre baseline vitals were recorded. Anesthesia induced with thiopentone sodium and intubation done with the help of succinylcholine and maintained with oxygen, nitrous oxide and isoflurane. After 1 min of intubation, maintenance infusion of dexmedetomidine (0.4 mcg/kg/hr and 0.7 mcg/kg/hr for patients allotted in 2 separate groups was started and stopped 15 min before end of surgery. Hemodynamic parameters and any reduction in the doses of volatile anaesthetics and muscle relaxants was noted. RESULTS Dexmedetomidine infusion (0.4 mcg/kg/hr and 0.7 mcg/kg/hr in both groups reduced the requirements of muscle relaxants and volatile anaesthetics. Hemodynamic stability was better in the group receiving 0.4 mcg/kg/hr. Patients receiving 0.7 mcg/kg/hr had higher incidence of hypotension, bradycardia and delayed emergence from anaesthesia. CONCLUSION Dexmedetomidine infusion at 0.4 mcg/kg/hr during maintenance of anaesthesia in spine surgery, FESS and middle ear surgery would be good option to reduce the requirements of volatile anaesthetics, muscle relaxants and for better hemodynamic stability. OBJECTIVE OF STUDY: Primary Objective To compare and evaluate the hemodynamic effects and reduction in requirements of volatile anaesthetics and muscle relaxants with two different doses of dexmedetomidine infusion during maintenance of general anaesthesia in patients undergoing spine, FESS and middle ear surgeries.

  13. Influence of the dose rate in the PVDF degradation processes

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Adriana S.M.; Pereira, Claubia, E-mail: adriananuclear@yahoo.com.br, E-mail: claubia@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Gual, Maritza R., E-mail: maritzargual@gmail.com [Instituto Superior de Tecnologias y Ciencias Aplicadas (InsTEC), Departamento de Ingenieria Nuclear, La Habana (Cuba); Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    Modification in polymeric structure of plastic material can be brought either by conventional chemical means or by exposure to ionization radiation from gamma radioactive sources or highly accelerated electrons. The prominent drawbacks of chemical cross-linking typically involve the generation by products such as peroxide degradation. Radiation cross-linking technologies include: application in cable and wire, application in rubber tyres, radiation vulcanization of rubber latex, polymer recycling, hydrogels etc. The degradation of PVDF polymer exposed to gamma irradiation in oxygen atmosphere in high dose rate has been studied and compared to obtained under smaller dose rates. The samples were irradiated with a Co-60 source at constant dose rate (12 kGy/h and 2,592 kGy/h), with doses ranging from 100 kGy to 3,000 kGy. Different dose rate determine the prevalence of the processes being evaluated in this work by thermal measurements and infrared spectroscopy. It is shown that the degradation processes involve chain scissions and crosslink formation. The formation of oxidation products was shown at the surface of the irradiated film. The FTIR data revealed absorption bands at 1730 and 1853 cm{sup -1} which were attributed to the stretch of C=O bonds, at 1715 and 1754 cm{sup -1} which were attributed to the C=C stretching and at 3518, 3585 and 3673 cm{sup -1} which were associated with NH stretch of NH{sub 2} and OH. Thermogravimetric studies reveal that the irradiation induced the increasing residues and decrease of the temperature of the decomposition start. (author)

  14. Influence of the dose rate in the PVDF degradation processes

    International Nuclear Information System (INIS)

    Batista, Adriana S.M.; Pereira, Claubia; Gual, Maritza R.; Faria, Luiz O.

    2015-01-01

    Modification in polymeric structure of plastic material can be brought either by conventional chemical means or by exposure to ionization radiation from gamma radioactive sources or highly accelerated electrons. The prominent drawbacks of chemical cross-linking typically involve the generation by products such as peroxide degradation. Radiation cross-linking technologies include: application in cable and wire, application in rubber tyres, radiation vulcanization of rubber latex, polymer recycling, hydrogels etc. The degradation of PVDF polymer exposed to gamma irradiation in oxygen atmosphere in high dose rate has been studied and compared to obtained under smaller dose rates. The samples were irradiated with a Co-60 source at constant dose rate (12 kGy/h and 2,592 kGy/h), with doses ranging from 100 kGy to 3,000 kGy. Different dose rate determine the prevalence of the processes being evaluated in this work by thermal measurements and infrared spectroscopy. It is shown that the degradation processes involve chain scissions and crosslink formation. The formation of oxidation products was shown at the surface of the irradiated film. The FTIR data revealed absorption bands at 1730 and 1853 cm -1 which were attributed to the stretch of C=O bonds, at 1715 and 1754 cm -1 which were attributed to the C=C stretching and at 3518, 3585 and 3673 cm -1 which were associated with NH stretch of NH 2 and OH. Thermogravimetric studies reveal that the irradiation induced the increasing residues and decrease of the temperature of the decomposition start. (author)

  15. The long-term effects of switching from active intravenous bisphosphonate treatment to low-dose maintenance therapy in children with osteogenesis imperfecta.

    Science.gov (United States)

    Biggin, Andrew; Zheng, Linda; Briody, Julie N; Coorey, Craig P; Munns, Craig F

    2015-01-01

    Intravenous bisphosphonate therapy is the first-line treatment in moderate-to-severe osteogenesis imperfecta (OI), but there are varied treatment protocols with little data on long-term efficacy. This study evaluates the clinical outcomes when transitioning from active bisphosphonate treatment to maintenance therapy. A retrospective review was conducted on 17 patients before treatment, following active treatment (zoledronate 0.05 mg/kg 6-monthly or pamidronate 6-9 mg/kg/year) and after establishment on maintenance treatment for more than 2 years (zoledronate 0.025 mg/kg 6-monthly or pamidronate lean tissue mass increased during active treatment. These improvements were maintained during the period of maintenance treatment. Vertebral height improved in fractured thoracic vertebrae from pre-treatment to active therapy and improved further during maintenance treatment. Metacarpal cortical thickness and relative cortical area also increased over the treatment periods. Maintenance intravenous bisphosphonate therapy preserved the beneficial effects of active treatment at the doses stated above. Further studies are required to determine the optimal bisphosphonate treatment regimen in the management of children with OI. © 2015 S. Karger AG, Basel.

  16. Influence of TLD position on the estimate of fetal dose

    International Nuclear Information System (INIS)

    Majola, J.; Jamieson, T.J.

    1995-11-01

    This report examines the adequacy of the practice of using a single dosimeter worn at the front of the body as an estimate of the dose received by nuclear medicine technologies. In order to investigate this, a group of approximately 50 technologists at 9 different hospitals were double-badged, i.e. provided with front and back dosimeters, and the ratio of front to back dose computed. Both aggregate data and hospital-specific data are presented and accompanied by several forms of statistical analysis. Apparent trends and possible explanations are discussed. Recommendations are provided for additional studies relating to the badging of nuclear medicine technologists. (author). 125 refs., 15 tabs., 13 figs

  17. Influence of TLD position on the estimate of fetal dose

    Energy Technology Data Exchange (ETDEWEB)

    Majola, J; Jamieson, T J [Science Applications International Corp., Ottawa, ON (Canada)

    1995-11-01

    This report examines the adequacy of the practice of using a single dosimeter worn at the front of the body as an estimate of the dose received by nuclear medicine technologies. In order to investigate this, a group of approximately 50 technologists at 9 different hospitals were double-badged, i.e. provided with front and back dosimeters, and the ratio of front to back dose computed. Both aggregate data and hospital-specific data are presented and accompanied by several forms of statistical analysis. Apparent trends and possible explanations are discussed. Recommendations are provided for additional studies relating to the badging of nuclear medicine technologists. (author). 125 refs., 15 tabs., 13 figs.

  18. On the influence of the exposure model on organ doses

    International Nuclear Information System (INIS)

    Drexler, G.; Eckerl, H.

    1988-01-01

    Based on the design characteristics of the MIRD-V phantom, two sex-specific adult phantoms, ADAM and EVA were introduced especially for the calculation of organ doses resulting from external irradiation. Although the body characteristics of all the phantoms are in good agreement with those of the reference man and woman, they have some disadvantages related to the location and shape of organs and the form of the whole body. To overcome these disadvantages related to the location and shape of organs and form of the whole body. To overcome these disadvantages related to the location and shape of organs and the form of the whole body. To overcome these disadvantages and to obtain more realistic phantoms, a technique based on computer tomographic data (voxel-phantom) was developed. This technique allows any physical phantom or real body to be converted into computer files. The improvements are of special importance with regard to the skeleton, because a better modeling of the bone surfaces and separation of hard bone and bone marrow can be achieved. For photon irradiation, the sensitivity of the model on organ doses or the effective dose equivalent is important for operational radiation protection

  19. [Influence of dose regimen on gentamycin nephrotoxicity in rats].

    Science.gov (United States)

    Oliveira, V C; Tejos, C R; Hosaka, E M; Andrade, S C; Araújo, M; Vattimo, M F

    2001-06-01

    The acute renal failure (ARF), that still presents a right mortality rate (50%) can be defined as an abrupt decline of the glomerular filtration, resultant of ischemic or toxicity event. The drugs nephrotoxicity is one of the most frequent cause (27%) of ARF and it is suggested that the interval of administration of the drug can interfere in this side effect, however the best administration regimen is not very well established. This study evaluated the renal function of rats that received gentamicin (100 mg/kg) in one dose or in two doses (2 x 50 mg/kg), by intraperitoneal infusion. The results obtained in this research, indicated that the single infusion of gentamicin determined smaller nephrotoxicity by the reduction of serum concentration of this drug in 24 hours, decreasing the intracellular accumulation of this gentamicin, which is one of the main cellular mechanisms of this renal injury. The single dose treatment regime, otherwise, shows advantages not only related to the nephrotoxicity effect, but also it is relevant to the cost and safety, which can be rationable factors in the administration of this drug.

  20. Maintenance therapy of childhood acute lymphoblastic leukemia revisited-Should drug doses be adjusted by white blood cell, neutrophil, or lymphocyte counts?

    Science.gov (United States)

    Schmiegelow, Kjeld; Nersting, Jacob; Nielsen, Stine Nygaard; Heyman, Mats; Wesenberg, Finn; Kristinsson, Jon; Vettenranta, Kim; Schrøeder, Henrik; Weinshilboum, Richard; Jensen, Katrine Lykke; Grell, Kathrine; Rosthoej, Susanne

    2016-12-01

    6-Mercaptopurine (6MP) and methotrexate (MTX) based maintenance therapy is a critical phase of childhood acute lymphoblastic leukemia treatment. Wide interindividual variations in drug disposition warrant frequent doses adjustments, but there is a lack of international consensus on dose adjustment guidelines. To identify relapse predictors, we collected 28,255 data sets on drug doses and blood counts (median: 47/patient) and analyzed erythrocyte (Ery) levels of cytotoxic 6MP/MTX metabolites in 9,182 blood samples (median: 14 samples/patient) from 532 children on MTX/6MP maintenance therapy targeted to a white blood cell count (WBC) of 1.5-3.5 × 10 9 /l. After a median follow-up of 13.8 years for patients in remission, stepwise Cox regression analysis did not find age, average doses of 6MP and MTX, hemoglobin, absolute lymphocyte counts, thrombocyte counts, or Ery levels of 6-thioguanine nucleotides or MTX (including its polyglutamates) to be significant relapse predictors. The parameters significantly associated with risk of relapse (N = 83) were male sex (hazard ratio [HR] 2.0 [1.3-3.1], P = 0.003), WBC at diagnosis (HR = 1.04 per 10 × 10 9 /l rise [1.00-1.09], P = 0.048), the absolute neutrophil count (ANC; HR = 1.7 per 10 9 /l rise [1.3-2.4], P = 0.0007), and Ery thiopurine methyltransferase activity (HR = 2.7 per IU/ml rise [1.1-6.7], P = 0.03). WBC was significantly related to ANC (Spearman correlation coefficient, r s  = 0.77; P best hematological target for dose adjustments of maintenance therapy. © 2016 Wiley Periodicals, Inc.

  1. INFLUENCE OF HIGH CORTISOL DOSES UPON THE SERUM IMMUNOGLOBULIN LEVEL

    OpenAIRE

    Voja Pavlovic; Zoran Pavlovic

    2001-01-01

    The effects of Cortisol upon the serum immunoglobulin concentration areexamined. The experiment involved male guinea pigs of the body weight from 300 to400 g that were nonnally fed and lived under the common laboratory conditions. Theguinea pigs were divided into an experimental and a control group. The experimentalgroup's guinea pigs were given every day (in a 6 days' period) a subcutaneous dose of80 g of corti sol/kg/per day, while the control group ones were given only one ml ofthe physiol...

  2. Evaluation of dose reduction versus standard dosing for maintenance of remission in patients with spondyloarthritis and clinical remission with anti-TNF (REDES-TNF): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Pontes, Caridad; Gratacós, Jordi; Torres, Ferran; Avendaño, Cristina; Sanz, Jesús; Vallano, Antoni; Juanola, Xavier; de Miguel, Eugenio; Sanmartí, Raimon; Calvo, Gonzalo

    2015-08-20

    Dose reduction schedules of tumor necrosis factor antagonists (anti-TNF) as maintenance therapy in patients with spondyloarthritis are used empirically in clinical practice, despite the lack of clinical trials providing evidence for this practice. To address this issue the Spanish Society of Rheumatology (SER) and Spanish Society of Clinical Pharmacology (SEFC) designed a 3-year multicenter, randomized, open-label, controlled clinical trial (2 years for inclusion and 1 year of follow-up). The study is expected to include 190 patients with axial spondyloarthritis on stable maintenance treatment (≥4 months) with any anti-TNF agent at doses recommended in the summary of product characteristics. Patients will be randomized to either a dose reduction arm or maintenance of the dosing regimen as per the official labelling recommendations. Randomization will be stratified according to the anti-TNF agent received before study inclusion. Patient follow-up, visit schedule, and examinations will be maintained as per normal clinical practice recommendations according to SER guidelines. The study aims to test the hypothesis of noninferiority of the dose reduction strategy compared with standard treatment. The first patients were recruited in July 2012, and study completion is scheduled for the end of April 2015. The REDES-TNF study is a pragmatic clinical trial that aims to provide evidence to support a medical decision now made empirically. The study results may help inform clinical decisions relevant to both patients and healthcare decision makers. EudraCT 2011-005871-18 (21 December 2011).

  3. Parasites and deleterious mutations: interactions influencing the evolutionary maintenance of sex.

    Science.gov (United States)

    Park, A W; Jokela, J; Michalakis, Y

    2010-05-01

    The restrictive assumptions associated with purely genetic and purely ecological mechanisms suggest that neither of the two forces, in isolation, can offer a general explanation for the evolutionary maintenance of sex. Consequently, attention has turned to pluralistic models (i.e. models that apply both ecological and genetic mechanisms). Existing research has shown that combining mutation accumulation and parasitism allows restrictive assumptions about genetic and parasite parameter values to be relaxed while still predicting the maintenance of sex. However, several empirical studies have shown that deleterious mutations and parasitism can reduce fitness to a greater extent than would be expected if the two acted independently. We show how interactions between these genetic and ecological forces can completely reverse predictions about the evolution of reproductive modes. Moreover, we demonstrate that synergistic interactions between infection and deleterious mutations can render sex evolutionarily stable even when there is antagonistic epistasis among deleterious mutations, thereby widening the conditions for the evolutionary maintenance of sex.

  4. Lung cancer incidence after exposure of rats to low doses of radon: influence of dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Morlier, J.P.; Morin, M.; Monchaux, G.; Fritsch, P.; Lafuma, J.; Masse, R. [CEA Centre d`Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Protection Technique; Pineau, J.F. [ALGADE, Bessines (France); Chameaud, J. [Compagnie Generale des Matieres Nucleaires (COGEMA), 87 - Razes (France)

    1994-12-31

    To study the effect on lung cancer incidence of a long exposure to low levels of radon, 500 male 3-months-old Sprague-Dawley rats, were exposed to a cumulative dose of 25 WLM of radon and its daughters, 6 hours a day, 5 days a week, during 18 months. Exposure conditions were controlled in order to maintain a defined PAEC: 42 x 10{sup 6} J.m{sup -3} (2 WL), in the range of domestic and environmental exposures. Animals were kept until they died or given euthanasia when moribund. Mean survival times were similar in both irradiated and control groups: 828 days (SD = 169) and 830 days (SD = 137), as well as lung cancer incidence, 0.60% at 25 WLM and 0.63% for controls. The incidence of lung lesions was compared statistically with controls and those previously obtained at cumulative exposures of 25 and 50 WLM delivered over a 4-6 month period, inducing a significant increase of lung cancer, 2.2% and 3.8% respectively. Such a comparison showed a decreased lung cancer incidence related to a decrease in the dose rate for low levels of radon exposure. (author).

  5. Lung cancer incidence after exposure of rats to low doses of radon: influence of dose rate

    International Nuclear Information System (INIS)

    Morlier, J.P.; Morin, M.; Monchaux, G.; Fritsch, P.; Lafuma, J.; Masse, R.; Chameaud, J.

    1994-01-01

    To study the effect on lung cancer incidence of a long exposure to low levels of radon, 500 male 3-months-old Sprague-Dawley rats, were exposed to a cumulative dose of 25 WLM of radon and its daughters, 6 hours a day, 5 days a week, during 18 months. Exposure conditions were controlled in order to maintain a defined PAEC: 42 x 10 6 J.m -3 (2 WL), in the range of domestic and environmental exposures. Animals were kept until they died or given euthanasia when moribund. Mean survival times were similar in both irradiated and control groups: 828 days (SD = 169) and 830 days (SD = 137), as well as lung cancer incidence, 0.60% at 25 WLM and 0.63% for controls. The incidence of lung lesions was compared statistically with controls and those previously obtained at cumulative exposures of 25 and 50 WLM delivered over a 4-6 month period, inducing a significant increase of lung cancer, 2.2% and 3.8% respectively. Such a comparison showed a decreased lung cancer incidence related to a decrease in the dose rate for low levels of radon exposure. (author)

  6. Influence of low dose ionizing radiation on amplification and antitumor activity of LAK/TIL cells

    International Nuclear Information System (INIS)

    Liu Wei; Hou Dianjun; Qiao Jianwei; Shang Ximei; Li Jieqing

    2000-01-01

    Objective: To study the influence of low dose ionization on amplification and antitumor activity of LAK/TIL cells. Methods: TIL cells isolated from Lewis lung cancer tissues and LAK cells from spleen of tumor-bearing mouse were irradiated with different low doses of X-rays and were cultured after irradiation. Results: Low dose ionizing radiation improved the amplification volume of LAK/TIL cells, decreased the cell death ratio in amplification process, and increased the toxicity of LAK/TIL cells, Conclusions: Low dose ionizing radiation can result in amplification of biologically activated lymphocytes, and decreases the death ratio of the cells in amplification process

  7. Dose rate influence in the response of the amber 3042 perspex Dosimeter, batch l

    International Nuclear Information System (INIS)

    Prieto Miranda, E. F.; Barrera Gonzalez, G.

    2001-01-01

    The answer of the dosimetry systems is affected by several factors , as the temperature, humidity, light, concentration of oxygen, dose rate, energy spectrum and one can also add the technological conditions of the irradiation process. It should be known as these factors influence in each one of the different dosimetry systems and this way to minimize their effect in the value of the absorbed dose and to obtain exact values . The objective of this paper is to know the influence of the dose rate in the value of the absorbed dose in the Amber 3042 Perspex dosimeters, Batch L, for different measurement wavelengths, as well as, the relation between the post-irradiation time and the induced specific absorbance value in function of the absorbed dose

  8. An analysis of the radiation field characteristics for extremity dose assessment during maintenance periods at nuclear power plants in Korea

    International Nuclear Information System (INIS)

    Kim, H. G.; Kong, T. Y.

    2012-01-01

    Workers who maintain the water chambers of steam generators during maintenance periods in nuclear power plants (NPPs) have a higher likelihood of high radiation exposure, even if they are exposed for a short period of time. In particular, it is expected that the hands of workers would receive the highest radiation exposure as a consequence of hand contact with radioactive materials. In this study, a characteristic analysis of inhomogeneous radiation fields for contact operations was conducted using thermoluminescent dosemeters for the whole body and extremities during maintenance periods at Korean NPPs. It was observed that inhomogeneous radiation fields for contact operations at NPPs were dominated by high-energy photons. (authors)

  9. Pharmacokinetics of and short-term virologic response to low-dose 400-milligram once-daily raltegravir maintenance therapy.

    NARCIS (Netherlands)

    Ananworanich, J.; Gorowara, M.; Avihingsanon, A.; Kerr, S.J.; Heesch, N. van; Khongpetch, C.; Uanithirat, A.; Hill, A.; Ruxrungtham, K.; Burger, D.M.

    2012-01-01

    Because studies showed similar viral suppression with lower raltegravir doses and because Asians usually have high antiretroviral concentrations, we explored low-dose raltegravir therapy in Thais. Nineteen adults on raltegravir at 400 mg twice daily (BID) with HIV RNA loads of <50 copies/ml were

  10. Robotic stereotactic radioablation of breast tumors: Influence of beam size on the absorbed dose distributions

    International Nuclear Information System (INIS)

    Garnica-Garza, H.M.

    2016-01-01

    Robotic stereotactic radioablation (RSR) therapy for breast tumors has been shown to be an effective treatment strategy when applied concomitantly with chemotherapy, with the purpose of reducing the tumor volume thus making it more amenable for breast conserving surgery. In this paper we used Monte Carlo simulation within a realistic patient model to determine the influence that the variation in beam collimation radius has on the resultant absorbed dose distributions for this type of treatment. Separate optimized plans were obtained for treatments using 300 circular beams with radii of 0.5 cm, 0.75 cm, 1.0 cm and 1.5 cm. Cumulative dose volume histograms were obtained for the gross, clinical and planning target volumes as well as for eight organs and structures at risk. Target coverage improves as the collimator size is increased, at the expense of increasing the volume of healthy tissue receiving mid-level absorbed doses. Interestingly, it is found that the maximum dose imparted to the skin is highly dependent on collimator size, while the dosimetry of other structures, such as both the ipsilateral and contralateral lung tissue are basically unaffected by a change in beam size. - Highlights: • Stereotactic body radiation therapy of breast tumors is analyzed using Monte Carlo simulation. • The influence of beam collimation on the absorbed dose distributions is determined. • Large field sizes increase target dose uniformity and midlevel doses to healthy structures. • Skin dose is greatly affected by changes in beam collimation.

  11. Unmasking of Partial Diabetes Insipidus during Stress but Not Maintenance Dosing of Glucocorticoids in an Infant with Septo-Optic Dysplasia

    Directory of Open Access Journals (Sweden)

    Loechner KarenJ

    2011-03-01

    Full Text Available Background. It is well acknowledged that glucocorticoid (GC replacement can unmask diabetes insipidus (DI in subjects with hypopituitarism. Objective. To increase the awareness and monitoring for transient and symptomatic DI in children with partial hypopituitarism during periods in which increased GC needs are required. Methods/Case. A 2-month-old female infant with septo-optic dysplasia (SOD; on thyroid and maintenance GC replacement therapy at 8 mg/m2/day developed transient DI during 2 separate episodes of stress (one hypothermia, one febrile when stress dosing of GC (25 mg/m2/day was instituted. Conclusion. Children not diagnosed with DI during initial evaluation for hypopituitarism may benefit from rescreening of serum sodium levels during acute periods of stress that demand "stress" GC dosing. This will permit treatment and/or increased vigilance for ensuing permanent DI.

  12. Dose-associated changes in safety and efficacy parameters observed in a 24-week maintenance trial of olanzapine long-acting injection in patients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Watson Susan B

    2011-02-01

    Full Text Available Abstract Background In a recently published 24-week maintenance study of olanzapine long-acting injection (LAI in schizophrenia (Kane et al., 2010, apparent dose-associated changes were noted in both efficacy and safety parameters. To help clinicians balance safety and efficacy when choosing a dose of olanzapine LAI, we further studied these changes. Methods Outpatients with schizophrenia who had maintained stability on open-label oral olanzapine for 4 to 8 weeks were randomly assigned to "low" (150 mg/2 weeks; N = 140, "medium" (405 mg/4 weeks; N = 318, or "high" (300 mg/2 weeks; N = 141 dosages of olanzapine LAI for 24 weeks. Potential relationships between dose and several safety or efficacy measures were examined via regression analysis, the Jonckheere-Terpstra test (continuous data, or the Cochran-Armitage test (categorical data. Results Safety parameters statistically significantly related to dose were mean weight change (low: +0.67 [SD = 4.38], medium: +0.89 [SD = 3.87], high: +1.70 [SD = 4.14] kg, p = .024; effect size [ES] = 0.264 high vs. low dose, mean change in prolactin (low: -5.61 [SD = 12.49], medium: -2.76 [SD = 19.02], high: +3.58 [SD = 33.78] μg/L, p = .001; ES = 0.410 high vs. low dose, fasting triglycerides change from normal at baseline to high (low: 3.2%, medium: 6.0%, high: 18.9%, p = .001; NNT = 7 high vs. low dose and fasting high-density lipoprotein cholesterol change from normal at baseline to low (low: 13.8%, medium: 19.6%, high: 30.7%, p = .019; NNT = 6 high vs. low dose. Efficacy measures significantly related to dose included Positive and Negative Syndrome Scale total score mean change (low: +2.66 [SD = 14.95], medium: -0.09 [SD = 13.47], high: -2.19 [SD = 13.11], p Conclusions Analyses of several safety and efficacy parameters revealed significant associations with dose of olanzapine LAI, with the highest dose generally showing greater efficacy as well as greater adverse changes in metabolic safety measures. When

  13. Rural settlements: social and ecological factors influencing on internal dose formation

    International Nuclear Information System (INIS)

    Visenberg, Yu.V; Vlasova, N.G.

    2008-01-01

    Full text: The aim of the present study is to reveal the reasons of difference in average internal doses in rural population living in the rural settlements situated on territories with equal levels of soil contamination; to show by clear examples that forming of internal dose is not only influenced directly by the contamination of the territory but also by number of factors of non-radiation origin. There were used data on internal doses as a result of WBC-measurements in rural inhabitants. Method of the study: there was applied the statistical analysis of the internal dose in rural population depending on the number of factors: radio-ecological represented by the transfer factor of radionuclides from soil to milk; environmental - closeness to the forest which, in its turn, determines intake of its resources by rural population; social - the number of population. There were selected settlements for the investigation whose residents had been WBC-measured for the period of 1990-2005's and their doses were evaluated. Thus, the conducted analysis shows that each of indirect (non-radiation) factors contributes in different way into formation of internal dose. The most significant of them is the social factor as follows from the results of the conducted analysis, represented by the number of inhabitants in a settlement. The internal dose depends not only on the level of contamination of the territory but also on the number of other factors: environmental, social, and radio-ecological. The influence of these factors on the process of dose formation in settlements should be considered simultaneously since neither of them is the leading one. Probably, there are other factors influencing on dose formation. Their investigation must be continued. (author)

  14. Influence of Routine MV CBCT Usage on Dose Distribution in Pelvic Radiotherapy

    International Nuclear Information System (INIS)

    Faj, D.; Kasabasic, M.; Ivkovic, A.; Tomas, I.; Jurkovic, S.

    2013-01-01

    The pelvic radiotherapy is a standard treatment for patients with cervical, uterine and rectal carcinomas. During radiation treatment open tabletop device or bellyboard is used to reduce the side effects of healthy surrounding tissue. Patients are continually adjusting to the bellyboard during the treatment which causes geometrical and dosage uncertainties and influences the results of the treatment. Therefore, to reduce these uncertainties, megavoltage cone-beam computed tomography (MV CBCT) system is used. The objective of this research was to evaluate the image acquisition dose delivered to patients from MV CBCT. MV CBCT imaging was simulated on 15 patients using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The influence of the routine MV CBCT usage on treatment plan was investigated by analyzing the changes in dose volume histograms, mean values and maximum doses in the planning volumes. Simulations have shown that daily usage of MV CBCT causes differences in the dose volume histograms. Moreover, for every patient mean value exceeded prescribed tolerance (±1% of the prescribed dose) and maximum value exceeded recommended maximum of 107% of the prescribed dose. The results have shown that MV CBCT dose to the patient should be a part of the RT plan.(author)

  15. Influence of Employee Involvement in Total Productive Maintenance Practices on Job Characteristics: The Malaysian Scenario

    Directory of Open Access Journals (Sweden)

    Aizzat Mohd. Nasurdin

    2005-09-01

    Full Text Available The main goal of this study is to examine whether the extent of involvement in Total Productive Maintenance (TPM practices has a positive effect on job characteristics. Data was gathered from a sample of 184 respondents derived from manufacturing companies in Malaysia. Results from the regression analyses revealed that the extent of employee’s involvement in TPM practices is positively related to the five core job dimensions (skill variety, task identity, task significance, autonomy, and feedback. Theoretical and managerial implications of the findings are discussed.

  16. Comparison of C-reactive protein levels with delivered dose of Kt/V in patients with end-stage renal disease on maintenance hemodialysis

    Directory of Open Access Journals (Sweden)

    Humayun Rashid

    2015-01-01

    Full Text Available The objective of our study is to compare the C-reactive protein (CRP levels with the delivered dose of dialysis in terms of Kt/V in patients undergoing maintenance hemodialysis (HD. This is a comparative, cross-sectional survey. The study was conducted at the HD unit of the Shaikh Zayed Hospital, Lahore, Pakistan. Patients who fulfilled the inclusion and exclusion criteria were enrolled in this study. The delivered dose of HD (Kt/V was assessed by an online clearance module (OCM in Fresenius machines at the end of every dialysis session and the weekly Kt/V was determined by adding all three Kt/V values. The serum CRP sample was taken after each session of HD and the mean CRP was calculated and considered elevated if it was >6 mg/dL. Both weekly Kt/V and CRP values were entered in a pre-designed proforma. Data were analyzed by using statistical software SPSS and P-value £0.05 was considered significant. Of 100 patients on maintenance HD, high serum CRP level (>6 mg/dL was found in 38 patients. When the Kt/V was compared with the CRP level, there was a negative correlation between the two parameters (r = 0.212, P = 0.032. Low Kt/V means dialysis inadequacy, which is associated with chronic inflammatory state, resulting in high CRP levels. We suggest that the quality of life of dialysis patients can be improved by offering an adequate dose of HD reflected by Kt/V ≥3.6/week.

  17. Influence of Daily Set-Up Errors on Dose Distribution During Pelvis Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, M.; Ivkovic, A.; Faj, D.; Rajevac, V.; Sobat, H.; Jurkovic, S.

    2011-01-01

    An external beam radiotherapy (EBRT) using megavoltage beam of linear accelerator is usually the treatment of choice for the cancer patients. The goal of EBRT is to deliver the prescribed dose to the target volume, with as low as possible dose to the surrounding healthy tissue. A large number of procedures and different professions involved in radiotherapy process, uncertainty of equipment and daily patient set-up errors can cause a difference between the planned and delivered dose. We investigated a part of this difference caused by daily patient set-up errors. Daily set-up errors for 35 patients were measured. These set-up errors were simulated on 5 patients, using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The differences in dose distributions between the planned and shifted ''geometry'' were investigated. Additionally, an influence of the error on treatment plan selection was checked by analyzing the change in dose volume histograms, planning target volume conformity index (CI P TV) and homogeneity index (HI). Simulations showed that patient daily set-up errors can cause significant differences between the planned and actual dose distributions. Moreover, for some patients those errors could influence the choice of treatment plan since CI P TV fell under 97 %. Surprisingly, HI was not as sensitive as CI P TV on set-up errors. The results showed the need for minimizing daily set-up errors by quality assurance programme. (author)

  18. Myelotoxicity after high-dose methotrexate in childhood acute leukemia is influenced by 6-mercaptopurine dosing but not by intermediate thiopurine methyltransferase activity

    DEFF Research Database (Denmark)

    Levinsen, Mette; Rosthøj, Susanne; Nygaard, Ulrikka

    2015-01-01

    Purpose: Through enhancement of 6-mercaptopurine (6MP) bioavailability and inhibition of purine de novo synthesis, high-dose methotrexate (HD-MTX) may increase incorporation into DNA of 6-thioguanine nucleotides, the cytotoxic metabolites of 6MP. Patients with intermediate activity of thiopurine...... methyltransferase (TPMTIA) have higher cytosol 6-thioguanine nucleotide levels. We investigated toxicity following HD-MTX during MTX/6MP maintenance therapy in relation to 6MP and TPMT. Methods: Using linear mixed models, we explored myelo- and hepatotoxicity in relation to 6MP dosage and TPMT phenotype following 1......,749 HD-MTX courses to 411 children with acute lymphoblastic leukemia on maintenance therapy. Results: The degree of myelosuppression following HD-MTX was similar for patients with TPMTIA and patients with high TPMT activity (TPMTHA), when HD-MTX started with same blood counts and 6MP doses. However...

  19. Cost-effectiveness analysis of a fixed-dose combination of indacaterol and glycopyrronium as maintenance treatment for COPD

    Directory of Open Access Journals (Sweden)

    Chan M

    2018-04-01

    Full Text Available Ming-Cheng Chan,1,* Elise Chia-Hui Tan,2 Ming-Chin Yang3,* 1Section of Chest Medicine, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan, Republic of China; 2National Research Institute of Chinese Medicine, Ministry of Health and Welfare, Taipei, Taiwan, Republic of China; 3Institute of Health Policy and Management, National Taiwan University, Taipei, Taiwan, Republic of China *These authors contributed equally to this work Objective: The aim of this study was to evaluate the cost-effectiveness of the long-acting beta-2 agonist (LABA/long-acting muscarinic antagonist (LAMA dual bronchodilator indacaterol/glycopyrronium (IND/GLY as a maintenance treatment for COPD patients from the perspective of health care payer in Taiwan. Patients and methods: We adopted a patient-level simulation model, which included a cohort of COPD patients aged ≥40 years. The intervention used in the study was the treatment using IND/GLY, and comparators were tiotropium or salmeterol/fluticasone combination (SFC. Data related to the efficacy of drugs, incidence of exacerbation, and utility were obtained from clinical studies. Direct costs were estimated from claims data based on the severity of COPD. The cycle length was 6 months (to match forced expiratory volume in 1 second [FEV1] data, and the time horizons included 1, 3, 5, 10 years, and lifetime. Deterministic and probabilistic sensitivity analyses were conducted to test the robustness of the model results. Costs were expressed in US dollars with a discount rate of 3.0%. Results: Compared to tiotropium and SFC, the incremental cost-effectiveness ratios (ICERs per quality-adjusted life year (QALY gained of patients treated with IND/GLY were US$5,987 and US$14,990, respectively. One-way sensitivity analysis revealed that the improvement in FEV1 provided by IND/GLY, the distribution of patients with regard to the severity of COPD, and acute exacerbation rate ratio were the key

  20. Influence of Flat-Panel Fluoroscopic Equipment Variables on Cardiac Radiation Doses

    International Nuclear Information System (INIS)

    Nickoloff, Edward L.; Lu Zhengfeng; Dutta, Ajoy; So, James; Balter, Stephen; Moses, Jeffrey

    2007-01-01

    Purpose. To assess the influence of physician-selectable equipment variables on the potential radiation dose reductions during cardiac catheterization examinations using modern imaging equipment. Materials. A modern bi-plane angiography unit with flat-panel image receptors was used. Patients were simulated with 15-30 cm of acrylic plastic. The variables studied were: patient thickness, fluoroscopy pulse rates, record mode frame rates, image receptor field-of-view (FoV), automatic dose control (ADC) mode, SID/SSD geometry setting, automatic collimation, automatic positioning, and others. Results. Patient radiation doses double for every additional 3.5-4.5 cm of soft tissue. The dose is directly related to the imaging frame rate; a decrease from 30 pps to 15 pps reduces the dose by about 50%. The dose is related to [(FoV) -N ] where 2.0 < N < 3.0. Suboptimal positioning of the patient can nearly double the dose. The ADC system provides three selections that can vary the radiation level by 50%. For pediatric studies (2-5 years old), the selection of equipment variables can result in entrance radiation doses that range between 6 and 60 cGy for diagnostic cases and between 15 and 140 cGy for interventional cases. For adult studies, the equipment variables can produce entrance radiation doses that range between 13 and 130 cGy for diagnostic cases and between 30 and 400 cGy for interventional cases. Conclusions. Overall dose reductions of 70-90% can be achieved with pediatric patients and about 90% with adult patients solely through optimal selection of equipment variables

  1. Influence on dose coefficients for workers of the new metabolic models

    International Nuclear Information System (INIS)

    Gomez Parada, I.M.; Rojo, A.M.

    1998-01-01

    The International Commission on Radiological Protection (ICRP) has recently reviewed the biokinetic models used in the internal contamination dose assessment. ICRP has adopted a new model for the human respiratory tract and has updated, in ICRP Publications 56, 67 and 69, some of the biokinetic models of ICRP Publication 30. In this paper, the dose coefficients for some selected radionuclides issued in ICRP Publication 68 are compared with those obtained using the software LUPED (LUng Dose Evaluation Program). The former were calculated using the new systemic models, while the latter are based on the old metabolic models. The aim is to know to what extent the new models for systematic retention influence the dose coefficients for workers. (author) [es

  2. Influence of environmental factors on some high dose dosimeter responses in Yazd Radiation Processing Center

    International Nuclear Information System (INIS)

    Ziaie, F.; Tahami, S.M.; Zareshahi, H.; Lanjanian, H.; Durrani, S.A.

    2008-01-01

    In this paper attempt has been made to study the influence of temperature and UV light (exist in laboratory due to the fluorescent light or diffused sunlight) on some high dose dosimetry responses that are being used in Yazd Radiation Processing Center (YRPC). The CTA, FWT and B3 film dosimeters were used for this investigation. The correction of the read response of the dosimeters to the real absorbed dose values is very important especially while we need to measure the precise dose values in the medical devices and in foodstuff materials. Yazd city is near to the desert, and so temperature and UV light due to the sun are very different in compare to other cities. Therefore, we tried to investigate the temperature and UV light effects on the dosimeter response in different doses and obtain its variation as a function of temperature (up to ∼60 0 C) and exposure time (up to ∼1 year), respectively

  3. An open randomized active-controlled clinical trial with low-dose SKA cytokines versus DMARDs evaluating low disease activity maintenance in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Martin-Martin LS

    2017-03-01

    Full Text Available LS Martin-Martin,1 F Giovannangeli,2 E Bizzi,2 U Massafra,2 E Ballanti,2 M Cassol,3 A Migliore2 1Department of Internal Medicine, Regina Apostolorum Hospital, 2Operative Unit of Rheumatology, 3Department of Internal Medicine, San Pietro Fatebenefratelli Hospital, Rome, Italy Background: Biologic agents are currently the strongest immunosuppressive drugs able to induce remission in rheumatoid arthritis (RA. One of the objectives of the medical scientific community now is how to maintain remission or low disease activity (LDA. The aim of this trial is to evaluate the contribution of low-dose sequential kinetic activation (SKA IL-4, IL-10, and anti-IL-1 antibodies (10 fg/mL in patients affected by RA in maintaining LDA or remission obtained after biological therapy. Method: This is a randomized, open, active-controlled, prospective, Phase IV trial. Disease activity score (DAS28, clinical disease activity index, simplified disease activity index, erythrocyte sedimentation rate and C-reactive protein levels, global health assessment, and pain visual analog scale were evaluated at baseline visit and then every 3 months together with an assessment of side effects till 12 months. Thirty-nine RA patients were enrolled and randomized to continue disease-modifying antirheumatic drugs (DMARDs therapy or to receive a combination of SKA low-dose cytokines formulated in concentration of 10 fg/mL orally administered at a dose of 20 drops/d for 12 consecutive months. Results: The rate of maintenance of LDA at 12 months was superior in the group treated with low-dose cytokines compared with patients treated with DMARDs, 66.7% and 42.1%, respectively; however, the difference between the groups was not statistically significant. No side effects were reported in both groups. Conclusion: This is the first study using a combination of three low-dose cytokines in RA, after data published on psoriasis. These data suggest that the use of a combination of low-dose SKA

  4. Potential influence of new doses of A-bomb after re-evaluation of epidemiological research

    International Nuclear Information System (INIS)

    Maruyama, T.

    1983-01-01

    Since the peaceful use of atomic energy appears essential for future human existence, we must provide risk estimates from low-dose exposures to human beings. The largest body of human data has been derived from the studies of atomic bomb survivors in Hiroshima and Nagasaki. Recently, it was proposed by an Oak Ridge National Laboratory group that the current free-in-air doses of atomic bombs are significantly different from the doses recalculated on the basis of the new output spectra of neutrons and gamma rays from the atomic bombs which were declassified by the US Department of Energy in 1976. A joint commission on dose re-evaluation of the United States of America and Japan was established in 1981 to pursue the dose reassessment programme between US and Japanese research groups and to decide an agreed best estimate of organ or tissue doses in survivors as soon as possible. The paper reviews the physical concepts of the re-evaluation of atomic bomb doses and discusses the potential influence of new dosimetric parameters on the epidemiological studies of the atomic bomb survivors in future, although the re-assessment programme is still in progress. (author)

  5. Mutational influences of low-dose and high let ionizing radiation in drosophila melanogaster

    Science.gov (United States)

    Lei, Huang; Fanjun, Kong; Sun, Yeqing

    For cosmic environment consists of a varying kinds of radiation particles including high Z and energy ions which was charactered with low-dose and high RBE, it is important to determine the possible biofuctions of high LET radiation on human beings. To analyse the possible effectes of mutational influences of low-dose and high-LET ionizing radiation, wild fruit flies drosophila melanogaster were irradiated by 12C6+ ions in two LET levels (63.3 and 30 keV/µum) with different low doses from 2mGy to 2000mGy (2, 20, 200, 2000mGy) in HIRFL (Heavy ion radiation facility laboratory, lanzhou, China).In the same LET value group, the average polymorphic frequency was elevated along with adding doses of irradation, the frequency in 2000 mGy dose samples was significantly higher than other samples (p<0.01).These results suggest that genomic DNA sequence could be effected by low-dose and high-LET ionizing radiation, the irradiation dose is an important element in genomic mutation frequency origination.

  6. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure, and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure, and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6, and 15 months) were given five doses (20, 60, 180, 540, and 1620 rad) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rad/day and 25 rad/min). Forty to sixty mice were used in each of the approximately 110 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replication. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the 15-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used

  7. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6 and l5 months) were given five doses (20, 60, 180, 540, and 1620 rads) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rads/day and 25 rads/min). Forty to sixty mice were used in each of the approximately 119 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replicaton. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the l5-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used. It was also concluded that radiaton-induced neoplastic transformaton was significantly greater in mice with a known genetic sensitivity to neoplastic disease than in mammals which do not normally have a significant incidence of tumours. (author)

  8. Maintenance of remission with low-dose olopatadine hydrochloride for itch in well-controlled chronic urticaria

    Directory of Open Access Journals (Sweden)

    Makino T

    2012-09-01

    Full Text Available Teruhiko Makino,1 Yoshiaki Takegami,1 Mati Ur Rehman,1 Yoko Yoshihisa,1 Waka Ishida,2 Takashi Toyomoto,3 Tadamichi Shimizu11Department of Dermatology, University of Toyama, Toyama, Japan; 2Department of Dermatology, Niigata Central Hospital, Joetsu, Japan; 3Department of Dermatology, Saiseikai Takaoka Hospital, Takaoka, JapanBackground: The long-term follow-up of chronic urticaria (CU is important to ensure the adequate treatment of patients. Olopatadine hydrochloride is one of the second-generation nonsedating antihistamines.Methods: This study was designed to assess the optimal dose of olopatadine to suppress symptoms of chronic urticarial itch in well-controlled patients. After CU patients were treated with 10 mg olopatadine, patients having a visual analogue scale (VAS itch score of less than 20 were randomly allocated into one of three groups: 10 mg/day (n = 35, 5 mg/day (n = 30, or no medication (n = 32.Results: The suppressive effects of both the 5 mg and 10 mg olopatadine treatments on the VAS itch score were more significant and longer lasting over a period of 4 weeks than the no-medication treatment. Both the 5-mg group and the 10-mg group showed improved urticarial symptoms and maintained their VAS itch score within normal limits compared to the no-medication group. The differences between the 5-mg and 10-mg groups were not significant.Conclusion: These results demonstrate that treatment with olopatadine at a dose of 5 mg once daily is effective and safe for the management and prevention of CU symptoms for itch in well-controlled patients.Keywords: chronic urticaria, olopatadine, dose, antihistamine, itch, histamine

  9. Aging irradiation of polymers. Dose-rate and test sequence influence

    International Nuclear Information System (INIS)

    Alba, C.; Carlin, F.; Chenion, J.; Lemaire, F.; Le Meur, M.; Petitjean, M.

    1984-05-01

    This work brings up results of the irradiation dose-rate influence on mechanical and electrical properties of technical polymer materials evolution. Polymer samples were subjected to 3.3.10 -2 Gy.s -1 and 2.8.10 -1 Gy.s -1 dose-rate. Heat and radiation simultaneous action is usualy simulated sequentialy. The hardest simulation on the polymer is the sequence of irradiation followed by thermal aging not the reverse. This study was carried out on eight polymer materials among those used in the electrical appliances for P.W.R. nuclear power plants [fr

  10. Perceptions That Influence the Maintenance of Scientific Integrity in Community-Based Participatory Research

    Science.gov (United States)

    Kraemer Diaz, Anne E.; Spears Johnson, Chaya R.; Arcury, Thomas A.

    2015-01-01

    Scientific integrity is necessary for strong science; yet many variables can influence scientific integrity. In traditional research, some common threats are the pressure to publish, competition for funds, and career advancement. Community-based participatory research (CBPR) provides a different context for scientific integrity with additional and…

  11. Influence of tube voltage on CT attenuation, radiation dose, and image quality: phantom study

    International Nuclear Information System (INIS)

    Li Fengtan; Li Dong; Zhang Yunting

    2013-01-01

    Objective: To assess the influence of tube current and tube voltage on the CT attenuation, radiation dose, and image quality. Methods: A total of 113 saline solutions with decreasing dilution of contrast medium (370 mg I/ml) was produced. MDCT scan was performed with 15 series of different settings of tube current and tube voltage. CT attenuations with 15 series of different settings were all measured, and influence of tube current and tube voltage on CT attenuations was analyzed. CT dose index (CTDIvol) was recorded. The CT attenuations with different tube voltage and current were compared with one-way ANOVA and Kruskal-Wallis rank sum test. The correlation of CT attenuation with different tube voltage and the influence of tube voltage and current on radiation dose and image quality were tested by correlation analysis. Results: Tube current (250, 200, 150, 100, and 50 mA) had no significant effect on CT attenuation (F = 0.001, 0.008, 0.075, P > 0.05), while tube voltage (120, 100, and 80 kV) had significant effect (H = 17.906, 17.906, 13.527, 20.124, 23.563, P < 0.05). The correlation between CT attenuation and tube voltage was determined with equation: CT attenuatio N_1_0_0 _k_V = 1.561 × CT attenuatio N_1_2_0 _k_v + 4.0818, CT attenuatio N_8_0 _k_v = 1.2131 × CT attenuatio N_1_2_0 _k_v + 0.9283. The influence of tube voltage on radiation dose and image quality was also analyzed, and equations were also obtained: N_1_2_0 -k_v = -5.9771 Ln (D_1_2_0 kv) + 25.412, N_1_0_0 _k_v = -10.544 Ln (D_1_0_0 _k_v) + 36.262, N_8_0 _k_v = -25.326 Ln (D_8_0 _k_v) + 62.816. According to the results of relationship among CT attenuation, radiation dose, and image quality, lower tube voltage with higher tube current can reduce the radiation dose. Conclusions: Lower tube voltage can reduce the radiation dose. However, CT attenuation was influenced, and correction should be done with the equations. (authors)

  12. Nuclear HMGA1 nonhistone chromatin proteins directly influence mitochondrial transcription, maintenance, and function

    International Nuclear Information System (INIS)

    Dement, Gregory A.; Maloney, Scott C.; Reeves, Raymond

    2007-01-01

    We have previously demonstrated that HMGA1 proteins translocate from the nucleus to mitochondria and bind to mitochondrial DNA (mtDNA) at the D-loop control region [G.A. Dement, N.R. Treff, N.S. Magnuson, V. Franceschi, R. Reeves, Dynamic mitochondrial localization of nuclear transcription factor HMGA1, Exp. Cell Res. 307 (2005) 388-401.] [11]. To elucidate possible physiological roles for such binding, we employed methods to analyze mtDNA transcription, mitochondrial maintenance, and other organelle functions in transgenic human MCF-7 cells (HA7C) induced to over-express an HA-tagged HMGA1 protein and control (parental) MCF-7 cells. Quantitative real-time (RT) PCR analyses demonstrated that mtDNA levels were reduced approximately 2-fold in HMGA1 over-expressing HA7C cells and flow cytometric analyses further revealed that mitochondrial mass was significantly reduced in these cells. Cellular ATP levels were also reduced in HA7C cells and survival studies showed an increased sensitivity to killing by 2-deoxy-D-glucose, a glycolysis-specific inhibitor. Flow cytometric analyses revealed additional mitochondrial abnormalities in HA7C cells that are consistent with a cancerous phenotype: namely, increased reactive oxygen species (ROS) and increased mitochondrial membrane potential (ΔΨ m ). Additional RT-PCR analyses demonstrated that gene transcripts from both the heavy (ND2, COXI, ATP6) and light (ND6) strands of mtDNA were up-regulated approximately 3-fold in HA7C cells. Together, these mitochondrial changes are consistent with many previous reports and reveal several possible mechanisms by which HMGA1 over-expression, a common feature of naturally occurring cancers, may affect tumor progression

  13. Influence of dose history on thermoluminescence response of Ge-doped silica optical fibre dosimeters

    International Nuclear Information System (INIS)

    Moradi, F.; Mahdiraji, G.A.; Dermosesian, E.; Khandaker, M.U.; Ung, N.M.; Mahamd Adikan, F.R.; Amin, Y.M.

    2017-01-01

    Nowadays, silica based optical fibres show enough potential to be used as TL dosimeters in different applications. Reuse of optical fibre as a practical dosimeter demands to complete removal of accumulated doses via previous irradiations. This work investigates the existence and/or effect of remnant doses in fibre dosimeter from the previous irradiations, and proposes a method to control this artifact. A single mode Ge-doped optical fibre is used as TL radiation sensor, while a well calibrated Gammacell with 60 Co source is used for irradiations. The effect of irradiation history on the TL response of optical fibres is surveyed extensively for doses ranged from 1 to 1000 Gy. The results show that the absorbed dose history in a fibre affects its response in the next irradiation cycles. It is shown that a dose history of around 100 Gy can increase the response of optical fibre by a factor of 1.72. The effect of annealing at higher temperatures on stabilizing the fibre response is also examined and results revealed that another alteration in the structure of trapping states occurs in glass medium which can change the sensitivity of fibres. Preservation of the sensitivity during successive irradiation cycles can be achieved by a proper annealing procedure accompanied by a pre-dose treatment. - Highlights: • Influence of dose history on TL characteristics of fibre dosimeter is explored. • The phenomenon behind the TL variation caused by dose history is discussed. • Effect of annealing temperature on performance of fibre dosimeter is studied. • Pre-treatment methods for mitigating variation in reproducibility are proposed.

  14. Influence of dose rate on the induction of simple and complex chromosome exchanges by gamma rays.

    Science.gov (United States)

    Loucas, Bradford D; Eberle, Richard; Bailey, Susan M; Cornforth, Michael N

    2004-10-01

    Single-color painting of whole chromosomes, or protocols in which only a few chromosomes are distinctively painted, will always fail to detect a proportion of complex exchanges because they frequently produce pseudosimple painting patterns that are indistinguishable from those produced by bona fide simple exchanges. When 24-color multi-fluor FISH (mFISH) was employed for the purpose of distinguishing (truly) simple from pseudosimple exchanges, it was confirmed that the acute low-LET radiation dose-response relationship for simple exchanges lacked significant upward curvature. This result has been interpreted to indicate that the formation of simple exchanges requires only one chromosome locus be damaged (e.g. broken) by radiation to initiate an exchange-not two, as classical cytogenetic theory maintains. Because a one-lesion mechanism implies single-track action, it follows that the production of simple exchanges should not be influenced by changes in dose rate. To examine this prediction, we irradiated noncycling primary human fibroblasts with graded doses of (137)Cs gamma rays at an acute dose rate of 1.10 Gy/min and compared, using mFISH, the yield of simple exchanges to that observed after exposure to the same radiation delivered at a chronic dose rate of 0.08 cGy/min. The shape of the dose response was found to be quasi-linear for both dose rates, but, counter to providing support for a one-lesion mechanism, the yield of simple aberrations was greatly reduced by protracted exposure. Although chronic doses were delivered at rates low enough to produce damage exclusively by single-track action, this did not altogether eliminate the formation of complex aberrations, an analysis of which leads to the conclusion that a single track of low-LET radiation is capable of inducing complex exchanges requiring up to four proximate breaks for their formation. For acute exposures, the ratio of simple reciprocal translocations to simple dicentrics was near unity.

  15. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  16. The influence of patient positioning uncertainties in proton radiotherapy on proton range and dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, Jakob, E-mail: jakob.liebl@medaustron.at [EBG MedAustron GmbH, 2700 Wiener Neustadt (Austria); Francis H. Burr Proton Therapy Center, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Department of Therapeutic Radiology and Oncology, Medical University of Graz, 8036 Graz (Austria); Paganetti, Harald; Zhu, Mingyao; Winey, Brian A. [Francis H. Burr Proton Therapy Center, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2014-09-15

    Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. For target volumes TCP decreases by more than 10% (absolute) occurred in less than 2.2% of the considered treatment scenarios for anatomy-based patient positioning and were nonexistent for fiducial-based patient positioning. EUD changes for target volumes were up to 35% (anatomy-based positioning) and 16% (fiducial-based positioning). Conclusions: The influence of patient positioning uncertainties on proton range in therapy of small lesions

  17. Influence of building maintenance, environmental factors, and seasons on airborne contaminants of swine confinement buildings.

    Science.gov (United States)

    Duchaine, C; Grimard, Y; Cormier, Y

    2000-01-01

    Eight swine confinement buildings, selected to cover the widest possible range of cleanliness, were visited twice during winter and once during summer to verify the range, seasonal variations, and correlations between biological and chemical contaminants. Physical aspects were graded for dirtiness (1 = clean, 10 = dirty), ventilation, air temperature, number of animals, building, and room size. Air samples were taken to measure relative humidity, CO2, ammonia, total dust, and microbiological counts and/or identification (bacteria and molds); endotoxin levels also were measured. During winter, average measurements and ranges were: CO2 = 0.304% (0.254 to 0.349%); ammonia = 19.6 ppm (1.9 to 25.9 ppm); dust = 3.54 mg/m3 (2.15 to 5.60 mg/m3). There were 883 cfu/m3 (547 to 2862 cfu/m3) of molds, 4.25 x 10(5) cfu/m3 (1.67 x 10(5) to 9.30 x 10(5) cfu/m3) of total bacteria, 29 cfu/m3 (3 to 94 cfu/m3) of thermophilic actinomycetes). A significant decrease in bacterial levels (p = 0.04), dust (p = 0.0008), ammonia (p = 0.005), and CO2 (p < 0.0001) was observed during summer sampling when compared with winter levels. Mold counts were positively correlated (p = 0.03) with dirtiness scores, while bacterial counts were negatively correlated with this parameter (p < 0.002), whereas bacteria and endotoxins were correlated with the number of animals (p < 0.05). Ambient gases (CO2 and ammonia) correlated with each other (p = 0.006). Bacteria were the most important contaminant in swine confinement buildings, and endotoxin levels found were also very high (mean = 4.9 x 10(3) EU/m3). We conclude that a wide range of air contamination exists in swine confinement buildings of different maintenance. There is a decrease in some of these contaminants during summer. Observed dirtiness of the swine confinement buildings has a poor predictive value concerning air quality.

  18. Improving Naval Aviation Maintenance Quality Management Processes at the Organizational Maintenance Level: The Influences of the International Standards Organization (ISO) 9000 Quality Management System on the Naval Aviation Maintenance Program (NAMP)

    National Research Council Canada - National Science Library

    Couch, Christopher

    1999-01-01

    ... to make them consistent with the ISO 9000 QMS. The NAMP is Naval aviation's overall guiding document that outlines command, administrative, and management relationships, and assigns maintenance policy and procedure responsibilities...

  19. In vitro dose comparison of Respimat® inhaler with dry powder inhalers for COPD maintenance therapy

    Directory of Open Access Journals (Sweden)

    Ciciliani A

    2017-05-01

    Full Text Available Anna-Maria Ciciliani,1,2 Peter Langguth,1 Herbert Wachtel2 1Institute of Pharmacy and Biochemistry, Faculty 09 (Chemistry, Pharmaceutics and Geosciences, Johannes Gutenberg University, Mainz, 2Analytical Development Department, Boehringer Ingelheim Pharma GmbH & Co. KG, Ingelheim, Germany Background: Combining in vitro mouth–throat deposition measurements, cascade impactor data and computational fluid dynamics (CFD simulations, four different inhalers were compared which are indicated for chronic obstructive pulmonary disease (COPD treatment.Methods: The Respimat inhaler, the Breezhaler, the Genuair, and the Ellipta were coupled to the idealized Alberta throat model. The modeled dose to the lung (mDTL was collected downstream of the Alberta throat model using either a filter or a next generation impactor (NGI. Idealized breathing patterns from COPD patient groups – moderate and very severe COPD – were applied. Theoretical lung deposition patterns were assessed by an individual path model.Results and conclusion: For the Respimat the mDTL was found to be 59% (SD 5% for the moderate COPD breathing pattern and 67% (SD 5% for very severe COPD breathing pattern. The percentages refer to nominal dose (ND in vitro. This is in the range of 44%–63% in vivo in COPD patients who display large individual variability. Breezhaler showed a mDTL of 43% (SD 2% for moderate disease simulation and 51% (SD 2% for very severe simulation. The corresponding results for Genuair are mDTL of 32% (SD 2% for moderate and 42% (SD 1% for very severe disease. Ellipta vilanterol particles showed a mDTL of 49% (SD 3% for moderate and 55% (SD 2% for very severe disease simulation, and Ellipta fluticasone particles showed a mDTL of 33% (SD 3% and 41% (SD 2%, respectively for the two breathing patterns. Based on the throat output and average flows of the different inhalers, CFD simulations were performed. Laminar and turbulent steady flow calculations indicated that

  20. Influence of burn-in on total-ionizing-dose effect of SRAM device

    International Nuclear Information System (INIS)

    Liu Minbo; Yao Zhibin; Huang Shaoyan; He Baoping; Sheng Jiangkun

    2014-01-01

    The influence of Burn-in on the total-ionizing-dose (TID) effect of SRAM device was investigated. SRAM devices of three different feature sizes were selected and irradiated by "6"0Co source with or without pre-irradiation Burn-in. Some parameters for radiation effect of SRAM device such as upset data, were measured, and the influence on the TID effect of different feature size SRAM devices with or without pre-irradiation Burn-in was obtained. The influence of different temperature Burn-in on radiation resistant capability of SRAM device was studied for 0.25 μm SRAM device. The results show that the smaller the device feature size is, the better the radiation-resistant capability of SRAM device is and the weaker the influence of Burn-in is. And the higher Burn-in temperature is, the more serious the influence of Burn-in on the total-dose radiation effect is. (authors)

  1. The influence of small dose radiation on some molecular and genetic parameters of peripheral blood lymphocytes

    International Nuclear Information System (INIS)

    Mel'nov, S.B.; Morozik, P.M.

    2001-01-01

    About 70% of Chernobyl radionuclide fallout was spread on the territory of Belarus. As a result, 2,5 million people now are living in contaminated areas under the pressure of the additional influence of low dose radiation. The aim of the current research is to definite the effects of this factor on some molecular and genetic characteristics of the children - prominent residents of the contaminated areas

  2. Influence of high dose irradiation on core structural and fuel materials in advanced reactors

    International Nuclear Information System (INIS)

    1998-08-01

    The IAEA International Working Group on Fast Reactors (IWGFR) periodically organizes meeting to discuss and review important aspects of fast reactor technology. The fifth meeting held in Obninsk, Russian Federation, 16-19 June 1997, was devoted to the influence of high dose irradiation on the mechanical properties of reactor core structural and fuel materials. The proceedings includes the papers submitted at this meeting each with a separate abstract

  3. Dose-Dependent and Lasting Influences of Intranasal Vasopressin on Face Processing in Men

    Directory of Open Access Journals (Sweden)

    Daniel Price

    2017-09-01

    Full Text Available Arginine vasopressin (AVP and related peptides have diverse effects on social behaviors in vertebrates, sometimes promoting affiliative interactions and sometimes aggressive or antisocial responses. The type of influence, in at least some species, depends on social contexts, including the sex of the individuals in the interaction and/or on the levels of peptide within brain circuits that control the behaviors. To determine if AVP promotes different responses to same- and other-sex faces in men, and if those effects are dose dependent, we measured the effects of two doses of AVP on subjective ratings of male and female faces. We also tested if any influences persist beyond the time of drug delivery. When AVP was administered intranasally on an initial test day, 20 IU was associated with decreased social assessments relative to placebo and 40 IU, and some of the effects persisted beyond the initial drug delivery and appeared to generalize to novel faces on subsequent test days. In single men, those influences were most pronounced, but not exclusive, for male faces, whereas in coupled men they were primarily associated with responses to female faces. Similar influences were not observed if AVP was delivered after placebo on a second test day. In a preliminary analysis, the differences in social assessments observed between men who received 20 and 40 IU, which we suggest primarily reflect lowered social assessments induced by the lower dose, appeared most pronounced in subjects who carry what has been identified as a risk allele for the V1a receptor gene. Together, these results suggest that AVP’s effects on face processing, and possibly other social responses, differ according to dose, depend on relationship status, and may be more prolonged than previously recognized.

  4. Assessing the influence of sustainable trail design and maintenance on soil loss

    Science.gov (United States)

    Marion, Jeff; Wimpey, Jeremy

    2017-01-01

    Natural-surfaced trail systems are an important infrastructure component providing a means for accessing remote protected natural area destinations. The condition and usability of trails is a critical concern of land managers charged with providing recreational access while preserving natural conditions, and to visitors seeking high quality recreational opportunities and experiences. While an adequate number of trail management publications provide prescriptive guidance for designing, constructing, and maintaining natural-surfaced trails, surprisingly little research has been directed at providing a scientific basis for this guidance. Results from a review of the literature and three scientific studies are presented to model and clarify the influence of factors that substantially influence trail soil loss and that can be manipulated by trail professionals to sustain high traffic while minimizing soil loss over time. Key factors include trail grade, slope alignment angle, tread drainage features, and the amount of rock in tread substrates. A new Trail Sustainability Rating is developed and offered as a tool for evaluating or improving the sustainability of existing or new trails.

  5. Assessing the influence of sustainable trail design and maintenance on soil loss.

    Science.gov (United States)

    Marion, Jeffrey L; Wimpey, Jeremy

    2017-03-15

    Natural-surfaced trail systems are an important infrastructure component providing a means for accessing remote protected natural area destinations. The condition and usability of trails is a critical concern of land managers charged with providing recreational access while preserving natural conditions, and to visitors seeking high quality recreational opportunities and experiences. While an adequate number of trail management publications provide prescriptive guidance for designing, constructing, and maintaining natural-surfaced trails, surprisingly little research has been directed at providing a scientific basis for this guidance. Results from a review of the literature and three scientific studies are presented to model and clarify the influence of factors that substantially influence trail soil loss and that can be manipulated by trail professionals to sustain high traffic while minimizing soil loss over time. Key factors include trail grade, slope alignment angle, tread drainage features, and the amount of rock in tread substrates. A new Trail Sustainability Rating is developed and offered as a tool for evaluating or improving the sustainability of existing or new trails. Published by Elsevier Ltd.

  6. Influence of the Mesh Geometry Evolution on Gearbox Dynamics during Its Maintenance

    Science.gov (United States)

    Dąbrowski, Z.; Dziurdź, J.; Klekot, G.

    2017-12-01

    Toothed gears constitute the necessary elements of power transmission systems. They are applied as stationary devices in drive systems of road vehicles, ships and crafts as well as airplanes and helicopters. One of the problems related to the toothed gears usage is the determination of their technical state or its evolutions. Assuming that the gear slippage velocity is attributed to vibrations and noises generated by cooperating toothed wheels, the application of a simple cooperation model of rolled wheels of skew teeth is proposed for the analysis of the mesh evolution influence on the gear dynamics. In addition, an example of utilising an ordinary coherence function for investigating evolutionary mesh changes related to the effects impossible to be described by means of the simple kinematic model is presented.

  7. What Predicts Exercise Maintenance and Well-Being? Examining The Influence of Health-Related Psychographic Factors and Social Media Communication.

    Science.gov (United States)

    Zhou, Xin; Krishnan, Archana

    2018-01-26

    Habitual exercising is an important precursor to both physical and psychological well-being. There is, thus, a strong interest in identifying key factors that can best motivate individuals to sustain regular exercise regimen. In addition to the importance of psychographic factors, social media use may act as external motivator by allowing users to interact and communicate about exercise. In this study, we examined the influence of health consciousness, health-oriented beliefs, intrinsic motivation, as willingness to communicate about health on social media, social media activity on exercise, and online social support on exercise maintenance and well-being on a sample of 532 American adults. Employing structural equation modeling, we found that health-oriented beliefs mediated the effect of health consciousness on intrinsic motivation which in turn was a significant predictor of exercise maintenance. Exercise maintenance significantly predicted both physical and psychological well-being. Extrinsic motivators, as measured by willingness to communicate about health on social media, social media activity on exercise, and online social support did not however significantly influence exercise maintenance. These findings have implications for the design and implementation of exercise-promoting interventions by identifying underlying factors that influence exercise maintenance.

  8. Influence of radiation dose on positive surgical margins in women undergoing breast conservation therapy

    International Nuclear Information System (INIS)

    DiBiase, Steven J.; Komarnicky, Lydia T.; Heron, Dwight E.; Schwartz, Gordon F.; Mansfield, Carl M.

    2002-01-01

    Purpose: Positive surgical margins adversely influence local tumor control in breast conservation therapy (BCT). However, reports have conflicted regarding whether an increased radiation dose can overcome this poor prognostic factor. In this study, we evaluated the influence of an increased radiation dose on tumor control in women with positive surgical margins undergoing BCT. Methods and Materials: Between 1978 and 1994, 733 women with pathologic Stage I-II breast cancer and known surgical margin status were treated at Thomas Jefferson University Hospital with BCT. Of these 733 patients, 641 women had a minimal tumor bed dose of 60 Gy and had documentation of their margin status; 509 had negative surgical margins, and 132 had positive surgical margins before definitive radiotherapy. Complete gross excision of the tumor and axillary lymph node sampling was obtained in all patients. The median radiation dose to the primary site was 65.0 Gy (range 60-76). Of the women with positive margins (n=132), the influence of higher doses of radiotherapy was evaluated. The median follow-up time was 52 months. Results: The local tumor control rate for patients with negative margins at 5 and 10 years was 94% and 88%, respectively, compared with 85% and 67%, respectively, for those women with positive margins (p=0.001). The disease-free survival rate for the negative margin group at 5 and 10 years was 91% and 82%, respectively, compared with 76% and 71%, respectively, for the positive margin group (p = 0.001). The overall survival rate of women with negative margins at 5 and 10 years was 95% and 90%, respectively. By comparison, for women with positive surgical margins, the overall survival rate at 5 and 10 years was 86% and 79%, respectively (p=0.008). A comparison of the positive and negative margin groups revealed that an increased radiation dose (whether entered as a dichotomous or a continuous variable) >65.0 Gy did not improve local tumor control (p=0.776). On Cox

  9. VERSHINA – A POLISH VILLAGE IN SIBERIA. FACTORS INFLUENCING LANGUAGE MAINTENANCE UNDER CHANGING SOCIAL, CULTURAL, ECONOMIC AND POLITICAL CONDITIONS

    Directory of Open Access Journals (Sweden)

    Michał Głuszkowski

    2011-01-01

    Full Text Available The article discusses factors influencing language maintenance under changing social, cultural, economic and political conditions of Polish minority in Siberia. The village of Vershina was founded in 1910 by Polish voluntary settlers from Little Poland.During its first three decades Vershina preserved Polish language,traditions, farming methods and machines and also the Roman Catholic religion. The changes came to a village in taiga in the1930s. Vershina lost its ethnocultural homogeneity because of Russian and Buryat workers in the local kolkhoz. Nowadays the inhabitants of Vershina regained their minority rights: religious, educational and cultural. However, during the years of sovietization and ateization, their culture and customs became much more similar to other Siberian villages. Polish language in Vershina is under strong influence of Russian, which is the language of education,administration, and surrounding villages. Children from Polish-Russian families become monolingual and use Polish very rare, only asa school subject and in contacts with grandparents. The process of abandoning mother tongue in Vershina is growing rapidly. However,there are some factors which may hinder the actual changes:the activity of local Polish organisations and Roman Catholic parish as well as folk group “Jazhumbek”.

  10. Influence of technical maintenance measures on ecological status of agricultural lowland rivers - Systematic review and implications for river management.

    Science.gov (United States)

    Bączyk, Anna; Wagner, Maciej; Okruszko, Tomasz; Grygoruk, Mateusz

    2018-06-15

    Intensification of agriculture and ongoing urban sprawl exacerbate pressures on rivers. Small rivers in agricultural landscapes are especially exposed to excessive technical actions implemented in order to allow for harvesting river water for irrigation, draining agricultural water and receiving sewage. Regular dredging and macrophyte removal strongly interfere with the global need for preserving river biodiversity that allows agricultural lowland rivers to remain refuges for a variety of species, and-accordingly-to keep water bodies resilient for the benefit of society. In order to provide a comprehensive look at the influence of agricultural lowland river management on the ecological status of these water bodies, we conducted a literature review and a meta-analysis. For the structured literature review we selected 203 papers reflecting on the response of aquatic ecosystems to dredging and macrophyte management actions. The database of scientific contributions developed for our study consists of papers written by the authors from 33 countries (first authorship) addressing dredging, macrophyte removal, status of fish and macroinvertebrates as well as the general ecological status of lowland agricultural rivers. We revealed that 96% of the analyzed papers indicated unilateral, negative responses of aquatic ecosystems, particularly macroinvertebrates, ichthyofauna and macrophyte composition, to maintenance measures. We revealed that studies conducted in the European Union on the ecological status of rivers appeared to significantly increase in quantity after the implementation of the Water Framework Directive. Finally, we concluded that day-to-day management of lowland agricultural rivers requires revision in terms of compliance with environmental conservation requirements and the recurrent implementation of technical measures for river maintenance. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Perceptions that influence the maintenance of scientific integrity in community-based participatory research.

    Science.gov (United States)

    Kraemer Diaz, Anne E; Spears Johnson, Chaya R; Arcury, Thomas A

    2015-06-01

    Scientific integrity is necessary for strong science; yet many variables can influence scientific integrity. In traditional research, some common threats are the pressure to publish, competition for funds, and career advancement. Community-based participatory research (CBPR) provides a different context for scientific integrity with additional and unique concerns. Understanding the perceptions that promote or discourage scientific integrity in CBPR as identified by professional and community investigators is essential to promoting the value of CBPR. This analysis explores the perceptions that facilitate scientific integrity in CBPR as well as the barriers among a sample of 74 professional and community CBPR investigators from 25 CBPR projects in nine states in the southeastern United States in 2012. There were variations in perceptions associated with team member identity as professional or community investigators. Perceptions identified to promote and discourage scientific integrity in CBPR by professional and community investigators were external pressures, community participation, funding, quality control and supervision, communication, training, and character and trust. Some perceptions such as communication and training promoted scientific integrity whereas other perceptions, such as a lack of funds and lack of trust could discourage scientific integrity. These results demonstrate that one of the most important perceptions in maintaining scientific integrity in CBPR is active community participation, which enables a co-responsibility by scientists and community members to provide oversight for scientific integrity. Credible CBPR science is crucial to empower the vulnerable communities to be heard by those in positions of power and policy making. © 2015 Society for Public Health Education.

  12. Influence of dose and dose rate on the physical properties of commercial papers commonly used in libraries and archives

    International Nuclear Information System (INIS)

    Area, María C.; Calvo, Ana M.; Felissia, Fernando E.; Docters, Andrea; Miranda, María V.

    2014-01-01

    The aim of this study was to evaluate the effects of dose and dose rate of gamma irradiation on the physical properties of commercial papers commonly used in libraries and archives to optimize the irradiation conditions. Three different brands of paper of different fiber compositions were treated, using a 3 2 factorial design with four replicates of the center point, with doses ranging from 2 to 11 kGy and dose rates between 1 and 11 kGy/h. Chemical, mechanical and optical properties were determined on the samples. With some differences between the different kinds of papers, tensile strength, elongation, TEA, and air resistance were in general, unaffected by the treatment. The minimum loss of tear resistance and brightness were obtained with doses in the range 4–6 kGy at any dose rate for all three kinds of paper. These conditions are ideal to remove insects and sufficient to eliminate fungus. - Highlights: • Gamma irradiation is a valid option to remove mold from books and documents. • We studied the effect of irradiation dose and dose rate on the physical properties of papers. • We found an optimum combination of dose and dose rate

  13. Influence of nuclear interactions in body tissues on tumor dose in carbon-ion radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Inaniwa, T., E-mail: taku@nirs.go.jp; Kanematsu, N. [Medical Physics Research Program, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-8555 (Japan); Tsuji, H.; Kamada, T. [Hospital, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2015-12-15

    Purpose: In carbon-ion radiotherapy treatment planning, the planar integrated dose (PID) measured in water is applied to the patient dose calculation with density scaling using the stopping power ratio. Since body tissues are chemically different from water, this dose calculation can be subject to errors, particularly due to differences in inelastic nuclear interactions. In recent studies, the authors proposed and validated a PID correction method for these errors. In the present study, the authors used this correction method to assess the influence of these nuclear interactions in body tissues on tumor dose in various clinical cases. Methods: Using 10–20 cases each of prostate, head and neck (HN), bone and soft tissue (BS), lung, liver, pancreas, and uterine neoplasms, the authors first used treatment plans for carbon-ion radiotherapy without nuclear interaction correction to derive uncorrected dose distributions. The authors then compared these distributions with recalculated distributions using the nuclear interaction correction (corrected dose distributions). Results: Median (25%/75% quartiles) differences between the target mean uncorrected doses and corrected doses were 0.2% (0.1%/0.2%), 0.0% (0.0%/0.0%), −0.3% (−0.4%/−0.2%), −0.1% (−0.2%/−0.1%), −0.1% (−0.2%/0.0%), −0.4% (−0.5%/−0.1%), and −0.3% (−0.4%/0.0%) for the prostate, HN, BS, lung, liver, pancreas, and uterine cases, respectively. The largest difference of −1.6% in target mean and −2.5% at maximum were observed in a uterine case. Conclusions: For most clinical cases, dose calculation errors due to the water nonequivalence of the tissues in nuclear interactions would be marginal compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response. In some extreme cases, however, these errors can be substantial. Accordingly, this correction method should be routinely applied to treatment planning in clinical practice.

  14. Influence of image slice thickness on rectal dose-response relationships following radiotherapy of prostate cancer

    Science.gov (United States)

    Olsson, C.; Thor, M.; Liu, M.; Moissenko, V.; Petersen, S. E.; Høyer, M.; Apte, A.; Deasy, J. O.

    2014-07-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose-response relationships. We investigated this for rectal bleeding using dose-volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman-Kutcher-Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose-response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice thickness

  15. Influence of clouds on the cosmic radiation dose rate on aircraft

    International Nuclear Information System (INIS)

    Pazianotto, Mauricio T.; Carlson, Brett V.; Federico, Claudio A.; Goncalez, Odair L.; Cortes-Giraldo, Miguel A.; Quesada, Jose Manuel M.; Palomo, Francisco R.; Pinto, Marcos Luiz de A.

    2014-01-01

    Flight missions were made in Brazilian territory in 2009 and 2011 with the aim of measuring the cosmic radiation dose rate incident on aircraft in the South Atlantic Magnetic Anomaly and to compare it with Monte Carlo simulations. During one of these flights, small fluctuations were observed in the vicinity of the aircraft with formation of Cumulonimbus clouds. Motivated by these observations, in this work, the authors investigated the relationship between the presence of clouds and the neutron flux and dose rate incident on aircraft using computational simulation. The Monte Carlo simulations were made using the MCNPX and Geant4 codes, considering the incident proton flux at the top of the atmosphere and its propagation and neutron production through several vertically arranged slabs, which were modelled according to the ISO specifications. The paper presents first-order calculation about the influence of Cumulonimbus clouds on the flux and dose rate due to cosmic neutrons in the atmosphere, at aircraft flight altitudes. The simulations show variations of the order of 5.5 % in the neutrons flux and 3.6 % of the dose rate due to the presence of the cloud. Such variations can extend up to ∼1.5 km from the edge of the cloud. The spectrum of neutrons within a cloud formation was observed undergo changes due to the neutron absorption and scattering processes with the water content inside the cloud. To accomplish these simulations, it is important to have a proper knowledge of the data libraries and nuclear models to be applied, since the simulation processes are strongly dependent on these factors. These results emphasise the importance of conducting more detailed studies on this topic, since the influence of clouds can change the dose and flux on aircraft overflying such formations, as well as could explain some of the fluctuations in the experimental dose rate data obtained in aircraft flights. Future studies should extend such simulations to different types of

  16. Influence of dose and dose rate on the physical properties of commercial papers commonly used in libraries and archives

    Science.gov (United States)

    Area, María C.; Calvo, Ana M.; Felissia, Fernando E.; Docters, Andrea; Miranda, María V.

    2014-03-01

    The aim of this study was to evaluate the effects of dose and dose rate of gamma irradiation on the physical properties of commercial papers commonly used in libraries and archives to optimize the irradiation conditions. Three different brands of paper of different fiber compositions were treated, using a 32 factorial design with four replicates of the center point, with doses ranging from 2 to 11 kGy and dose rates between 1 and 11 kGy/h. Chemical, mechanical and optical properties were determined on the samples. With some differences between the different kinds of papers, tensile strength, elongation, TEA, and air resistance were in general, unaffected by the treatment. The minimum loss of tear resistance and brightness were obtained with doses in the range 4-6 kGy at any dose rate for all three kinds of paper. These conditions are ideal to remove insects and sufficient to eliminate fungus.

  17. Influence of lung parameter values for the Brazilian population on inhalation dose

    International Nuclear Information System (INIS)

    Reis, Arlene A.; Lopes, Ricardo T.

    2009-01-01

    The Human Respiratory Tract Model (HRTM) proposed by the ICRP Publication 66 accounts for the morphology and physiology of the respiratory tract. The ICRP 66 presents deposition fraction in the respiratory tract regions considering reference values from Caucasian man. However, in order to obtain a more accurate assessment of intake and dose the ICRP recommends the use of specific information when they are available. The main objective of this study is to evaluate the influence in dose calculation to each region of the respiratory tract when physiological parameters from samples of Brazilian population, in different levels of exercise, are applied in the deposition model.The dosimetric model of HRTM was implemented in the software EXCEL for Windows and committed equivalent dose was determined for each respiratory tract region. First it was calculated the total number of nuclear transformations considering the fractional deposition of activity in each source tissue obtained by application of physiological and morphological Brazilian parameters in the deposition model and then it was calculated the total energy absorbed per unit mass in the target tissue.The variation in the fractional deposition in the compartments of the respiratory tract in changing the physiological parameters from Caucasian to Brazilian adult man causes variation in the number of total transformations and also in the equivalent dose in each region of the respiratory tract. The variations are not the same for all regions of the respiratory tract and depend on levels of exercise. (author)

  18. Intra-voxel heterogeneity influences the dose prescription for dose-painting with radiotherapy: a modelling study

    NARCIS (Netherlands)

    Petit, S.F.; Dekker, A.L.A.J.; Seigneuric, R.; Murrer, L.H.P.; Riel, van N.A.W.; Nordsmark, M.; Overgaard, J.; Lambin, Ph.; Wouters, B.G.

    2009-01-01

    The purpose of this study was to increase the potential of dose redistribution by incorporating estimates of oxygen heterogeneity within imaging voxels for optimal dose determination. Cellular oxygen tension (pO2) distributions were estimated for imaging-size-based voxels by solving oxygen

  19. The influence of social psychological factors on behaviour, stress and dose in Chernobyl affected areas

    International Nuclear Information System (INIS)

    Murphy, M.; Allen, P.

    1998-01-01

    During the 12 years since the Chernobyl nuclear accident, people in the affected areas have lived day to day with the risks of radiation. During these 12 years many countermeasures have been applied to minimise dose and thus reduce the threat to the health of the affected populations. Some of these countermeasures are aimed at changing daily life; for example, advice and restrictions on behaviours relating to the forest, consumption of forest produce and the consumption of private milk. In order to be effective, these countermeasures require action, or compliance, on the part of the affected populations. How have people in these areas responded to this risk and to the countermeasures employed to minimise the risk? A number of social psychological factors may be involved in peoples responses to this situation, including their perceptions of threat, the perceived costs and benefits of the behaviours involved, and the influence of other people. We examine the influence of these various social psychological factors on compliance behaviour, dose, and stress related health through a survey of people in the affected areas using quantitative questionnaire measures. SPARPA or Social psychological aspects of radiation protection after accidents, is a European Commission-sponsored project (F14C-CT96-0010) involving U. Surrey, Symlog and NRPB as well as partners in the CIS. Specific objectives include: to characterise, using quantitative methods, the nature and psychological impact of countermeasures and the influence of behaviour on dose, and to develop, guidance on the implementation of countermeasures, taking account of the social and psychological context. (authors)

  20. Influence of dosing times on cisplatin-induced peripheral neuropathy in rats

    International Nuclear Information System (INIS)

    Seto, Yoshihiro; Okazaki, Fumiyasu; Horikawa, Keiji; Zhang, Jing; Sasaki, Hitoshi; To, Hideto

    2016-01-01

    Although cis-diamminedichloro-platinum (CDDP) exhibits strong therapeutic effects in cancer chemotherapy, its adverse effects such as peripheral neuropathy, nephropathy, and vomiting are dose-limiting factors. Previous studies reported that chronotherapy decreased CDDP-induced nephropathy and vomiting. In the present study, we investigated the influence of dosing times on CDDP-induced peripheral neuropathy in rats. CDDP (4 mg/kg) was administered intravenously at 5:00 or 17:00 every 7 days for 4 weeks to male Sprague–Dawley rats, and saline was given to the control group. To assess the dosing time dependency of peripheral neuropathy, von-Frey test and hot-plate test were performed. In order to estimate hypoalgesia, the hot-plate test was performed in rats administered CDDP weekly for 4 weeks. On day 28, the withdrawal latency to thermal stimulation was significantly prolonged in the 17:00-treated group than in the control and 5:00-treated groups. When the von-Frey test was performed to assess mechanical allodynia, the withdrawal threshold was significantly lower in the 5:00 and 17:00-treated groups than in the control group on day 6 after the first CDDP dose. The 5:00-treated group maintained allodynia throughout the experiment with the repeated administration of CDDP, whereas the 17:00-treated group deteriorated from allodynia to hypoalgesia. It was revealed that the severe of CDDP-induced peripheral neuropathy was inhibited in the 5:00-treated group, whereas CDDP-treated groups exhibited mechanical allodynia. These results suggested that the selection of an optimal dosing time ameliorated CDDP-induced peripheral neuropathy. The online version of this article (doi:10.1186/s12885-016-2777-0) contains supplementary material, which is available to authorized users

  1. Radiosensitivity of Arabidopsis thaliana L. in condition of influence of low ionizing radiation doses

    International Nuclear Information System (INIS)

    Shershunova, V.I.

    2000-01-01

    Arabidopsis thaliana is a convenient genetic object. This work represents the date of laboratory experiments concerning research of influence of chronic γ-irradiation on plants of arabidopsis at rosette stage (short stemmed mutant Lansberg Erecta). The findings contribute to the high sensitivity of rosette stage of arabidopsis to irradiation by γ-rays in low doses (0.67-10.0 cGy). It is shown in depressing effects of ionising radiation on growth, development, vitality and bearing of plants, but also in hightened output morphological anomalies of plants and embryonic lethalities in pods. (authors)

  2. Influence of drug load and physical form of cinnarizine in new SNEDDS dosing regimens

    DEFF Research Database (Denmark)

    Siqueira, Scheyla D V S; Müllertz, Anette; Gräeser, Kirsten

    2017-01-01

    The aim of this work was to evaluate the influence of drug load and physical form of cinnarizine (CIN) in self-nanoemulsifying drug delivery systems (SNEDDS) on absorption in rats. Further, the predictivity of the dynamic in vitro lipolysis model was evaluated. The following dosing regimens were......, compared to the aqueous suspension. Since the drug level in the aqueous phase is traditionally considered as the fraction available for absorption, a lack of in vitro-in vivo relation was observed. This study revealed that the physical form of CIN in the current SNEDDS does not affect CIN absorption...

  3. Dose reduction at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.; Dionne, B.J.

    1983-01-01

    The collective dose equivalent at nuclear power plants increased from 1250 rem in 1969 to nearly 54,000 rem in 1980. This rise is attributable primarily to an increase in nuclear generated power from 1289 MW-y to 29,155 MW-y; and secondly, to increased average plant age. However, considerable variation in exposure occurs from plant to plant depending on plant type, refueling, maintenance, etc. In order to understand the factors influencing these differences, an investigation was initiated to study dose-reduction techniques and effectiveness of as low as reasonably achievable (ALARA) planning at light water plants. Objectives are to: identify high-dose maintenance tasks and related dose-reduction techniques; investigate utilization of high-reliability, low-maintenance equipment; recommend improved radioactive waste handling equipment and procedures; examine incentives for dose reduction; and compile an ALARA handbook

  4. Study of the influence of ionizing radiation on biometrical parameters of eggplantand tomato at different doses

    International Nuclear Information System (INIS)

    Guliyeva, L.M.; Eminova, N.M.; Jafarov, E.S.; Babayev, G.G.

    2014-01-01

    Full text : The problem of influence of low-dose of ionizing radiation on plants for a long time attracted attention of researchers. Increasing interest in this issue is caused by many circumstances, especially by global radiation contamination of environment. By this time in radiobiology it has been gained great data about the negative effects of ionizing radiation on plants. It is well known that at the time of germination seed is very susceptible to a variety of physical and chemical agents which are capable of impacting their development. It is appropriate to conduct studies reflecting changes in biometrical parameters of agricultural plants importance for Azerbaijan. It was seen that radiation influence increases the productivity of the plants, the size of the stems, fruits, and the color more saturated

  5. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    International Nuclear Information System (INIS)

    Yaparpalvi, R; Mynampati, D; Kuo, H; Garg, M; Tome, W; Kalnicki, S

    2016-01-01

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performed using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V_2_0 and V_5 to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm"3. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V_2_0 (+3.1%) and V_5 (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm

  6. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Yaparpalvi, R; Mynampati, D; Kuo, H; Garg, M; Tome, W; Kalnicki, S [Montefiore Medical Center, Bronx, NY (United States)

    2016-06-15

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performed using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates

  7. MSCT renal stone protocol; dose penalty and influence on management decision of patients: Is it really worth the radiation dose?

    Directory of Open Access Journals (Sweden)

    Ahmed Hamimi

    2016-03-01

    Conclusions: Considering time is of the essence; MSCT renal stone protocol using low dose technique is crucial in the management of renal stone in acute setting including the diagnosis and management decision.

  8. Influence of Erythropoietin Dose and Albumin Level on the Plasma Brain Natriuretic Peptide in Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Alsuwaida Abdulkareem

    2006-01-01

    Full Text Available Brain natriuretic peptide (BNP levels increase in patients with congestive heart failure. Theoretically, BNP levels can be helpful in the determination of the "dry weight" of hemodialysis patients. To evaluate the effect of hemodialysis on the plasma concentration of BNP and to determine the factors that affect BNP levels during hemodialysis in patients with chronic renal failure, we studied five stable patients with chronic renal failure. A total of 15 blood samples were obtained for BNP levels at 24, 48 and 72 hours after the last hemodialysis session. The plasma BNP levels did not change significantly either with ultrafiltration volume or with time since last dialysis. However, the BNP levels correlated positively with the erythropoietin (EPO dose (r=0.98, P< 0.001 and negatively with the serum albumin levels (r = 0.94, P=0.02. Univariate analysis showed that the EPO dose (P=0.001 and the albumin level (P=0.02 were significant predictors of BNP level. Adjusted multivariate analysis showed significant interaction between the EPO dose and the albumin level (P=0.01, P=0.03 respectively. In conclusion: the plasma BNP levels were not significantly influenced by ultrafiltration volume or time since last dialysis. However, the BNP levels may be a useful prognostic parameter for assessing the risk of cardiovascular morbidity and mortality in hemodialysis patients.

  9. A moderate dose of alcohol does not influence experience of social ostracism in hazardous drinkers

    Directory of Open Access Journals (Sweden)

    Joseph OL Buckingham

    2016-04-01

    Full Text Available Anecdotal and correlational evidence suggests a relationship between social ostracism and alcohol dependence. Furthermore, a recent fMRI investigation found differences in the neural correlates associated with ostracism in people with alcohol dependence compared to healthy controls. We predicted that acutely administered alcohol would reduce the negative effects of social ostracism. Alcohol (0.4g/kg or matched placebo was administered to a sample of 32 hazardous drinkers over two sessions in a randomized, double-blind, cross-over design. In each session, participants were exposed to an ostracism event via the computerized ball passing game, Cyberball. In order to quantify the effects of ostracism, the fundamental needs questionnaire was completed twice on each testing session; immediately after (i social inclusion and (ii social exclusion. Ostracism caused robust changes to scores on the fundamental needs questionnaire, in line with previous literature. Alcohol administration did not influence the effects of simulated social ostracism, which was supported by a Bayesian analysis. Exploratory analyses revealed a negative relationship between age and ostracism induced fundamental needs threat across both sessions. In conclusion, a moderate dose of alcohol did not influence experience of simulated social ostracism in hazardous drinkers. Further research is needed to establish the effects of alcohol administration on social ostracism using different doses and populations of alcohol users.

  10. Solubility of hot fuel particles from Chernobyl--influencing parameters for individual radiation dose calculations.

    Science.gov (United States)

    Garger, Evgenii K; Meisenberg, Oliver; Odintsov, Oleksiy; Shynkarenko, Viktor; Tschiersch, Jochen

    2013-10-15

    Nuclear fuel particles of Chernobyl origin are carriers of increased radioactivity (hot particles) and are still present in the atmosphere of the Chernobyl exclusion zone. Workers in the zone may inhale these particles, which makes assessment necessary. The residence time in the lungs and the transfer in the blood of the inhaled radionuclides are crucial for inhalation dose assessment. Therefore, the dissolution of several kinds of nuclear fuel particles from air filters sampled in the Chernobyl exclusion zone was studied. For this purpose filter fragments with hot particles were submersed in simulated lung fluids (SLFs). The activities of the radionuclides (137)Cs, (90)Sr, (239+240)Pu and (241)Am were measured in the SLF and in the residuum of the fragments by radiometric methods after chemical treatment. Soluble fractions as well as dissolution rates of the nuclides were determined. The influence of the genesis of the hot particles, represented by the (137)Cs/(239+240)Pu ratio, on the availability of (137)Cs was demonstrated, whereas the dissolution of (90)Sr, (239+240)Pu and (241)Am proved to be independent of genesis. No difference in the dissolution of (137)Cs and (239+240)Pu was observed for the two applied types of SLF. Increased solubility was found for smaller hot particles. A two-component exponential model was used to describe the dissolution of the nuclides as a function of time. The results were applied for determining individual inhalation dose coefficients for the workers at the Chernobyl construction site. Greater dose coefficients for the respiratory tract and smaller coefficients for the other organs were calculated (compared to ICRP default values). The effective doses were in general lower for the considered radionuclides, for (241)Am even by one order of magnitude. © 2013 Elsevier B.V. All rights reserved.

  11. Factors influencing completion of multi-dose vaccine schedules in adolescents: a systematic review

    Directory of Open Access Journals (Sweden)

    K. E. Gallagher

    2016-02-01

    Full Text Available Abstract Background Completion of multiple dose vaccine schedules is crucial to ensure a protective immune response, and maximise vaccine cost-effectiveness. While barriers and facilitators to vaccine uptake have recently been reviewed, there is no comprehensive review of factors influencing subsequent adherence or completion, which is key to achieving vaccine effectiveness. This study identifies and summarises the literature on factors affecting completion of multi-dose vaccine schedules by adolescents. Methods Ten online databases and four websites were searched (February 2014. Studies with analysis of factors predicting completion of multi-dose vaccines were included. Study participants within 9–19 years of age were included in the review. The defined outcome was completion of the vaccine series within 1 year among those who received the first dose. Results Overall, 6159 abstracts were screened, and 502 full texts were reviewed. Sixty one studies were eligible for this review. All except two were set in high-income countries. Included studies evaluated human papillomavirus vaccine, hepatitis A, hepatitis B, and varicella vaccines. Reported vaccine completion rates, among those who initiated vaccination, ranged from 27 % to over 90 %. Minority racial or ethnic groups and inadequate health insurance coverage were risk factors for low completion, irrespective of initiation rates. Parental healthcare seeking behaviour was positively associated with completion. Vaccine delivery in schools was associated with higher completion than delivery in the community or health facilities. Gender, prior healthcare use and socio-economic status rarely remained significant risks or protective factors in multivariate analysis. Conclusions Almost all studies investigating factors affecting completion have been carried out in developed countries and investigate a limited range of variables. Increased understanding of barriers to completion in adolescents will

  12. Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Rush, E.R. [School of Health Sciences, University of Ulster, Shore Road, Newtownabbey, Belfast BT37 0QB (United Kingdom)]. E-mail: emmaroserush@hotmail.com; Thompson, N.A. [School of Health Sciences, University of Ulster, Shore Road, Newtownabbey, Belfast BT37 0QB (United Kingdom)

    2007-08-15

    Purpose: The aim of this study was to investigate the influence that collimator and technique choice had on the radiation dose detected at the thyroid gland position, during intra-oral examinations of the upper and lower teeth. Radiation dose reduction from a different perspective, other than the application of lead-rubber shielding, was addressed. Methods: A study was performed at a regional dental school with the use of a phantom head/neck and a radiation dosemeter, to measure the radiation dose detected at the thyroid gland position. The radiation dose was assessed for two intra-oral techniques (paralleling and bisecting angle), and two collimators (rectangular and circular). The radiation dose was also assessed with and without the application of a thyroid shield. Standard descriptive statistics, followed by inferential statistics were applied to the data. Results: There was a significant reduction in the radiation dose detected at the thyroid gland position, when employing the paralleling technique (66.7%) and rectangular collimator (45.5%). Other factors, for example the tooth/teeth under examination, were also found to influence the radiation dose detected. Conclusion: Radiation dose reductions using the paralleling technique and rectangular collimator were outlined. The use of this low dose combination within dental practices remains limited, therefore, continued awareness and acceptance of radiation hazards need to be addressed.

  13. Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

    International Nuclear Information System (INIS)

    Rush, E.R.; Thompson, N.A.

    2007-01-01

    Purpose: The aim of this study was to investigate the influence that collimator and technique choice had on the radiation dose detected at the thyroid gland position, during intra-oral examinations of the upper and lower teeth. Radiation dose reduction from a different perspective, other than the application of lead-rubber shielding, was addressed. Methods: A study was performed at a regional dental school with the use of a phantom head/neck and a radiation dosemeter, to measure the radiation dose detected at the thyroid gland position. The radiation dose was assessed for two intra-oral techniques (paralleling and bisecting angle), and two collimators (rectangular and circular). The radiation dose was also assessed with and without the application of a thyroid shield. Standard descriptive statistics, followed by inferential statistics were applied to the data. Results: There was a significant reduction in the radiation dose detected at the thyroid gland position, when employing the paralleling technique (66.7%) and rectangular collimator (45.5%). Other factors, for example the tooth/teeth under examination, were also found to influence the radiation dose detected. Conclusion: Radiation dose reductions using the paralleling technique and rectangular collimator were outlined. The use of this low dose combination within dental practices remains limited, therefore, continued awareness and acceptance of radiation hazards need to be addressed

  14. Influence of limestone doses in the Manganese absorption by Brachiaria decumbens

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Fulas, Paulo M.M.; Saiki, Mitiko; Primavesi, Odo; Primavesi, Ana C.

    2005-01-01

    To restore a degraded pasture of Brachiaria decumbens, located in Sao Carlos - SP, Southeastern Brazil, under tropical climate, an experiment was carried out to study the influence of different methods of the limestone doses application on manganese absorption by the aboveground part of the forage, during 3 years of treatment. The experimental design was randomized block, with 6 replications and 8 treatments. The 100m 2 blocks were established in the pasture. Each block received a sequence of limestone doses (0, 1, 2, 4, and 8 t/ha) applied on soil surface with NK and, 2 t/ha applied on soil surface with plus one annual application of 1t/ha and NK, 4t/ha buried in the soil with NK, 4t/ha applied on soil surface without NK. Forages samples were collected 14 cm above soil surface. Instrumental neutron activation analysis (INAA) followed by gamma-ray spectrometry was the analytical method used to determine manganese content. The statistical analysis showed some significant variations of this element absorption by the plant with regard to the treatments, but anything that could compromise the mineral nutrition of forage. Moreover, the quality of forage for the animal feeding showed suitable agreement to manganese requirement. INAA showed that it can be an alternative option for agronomical researches that require the knowledge of the manganese concentration. (author)

  15. Shielding effect of building to natural radiation and its influence to population dose evaluation

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Itoh, Kazuo; Yoshimura, Toshiaki.

    1980-01-01

    This work investigated the shielding effect of the building which is indispensable for the accurate evaluation of the population dose of external exposure from natural radiation. At first, the attenuation coefficients of various building materials were measured and found to agree with the calculated values within 10% errors. The shielding factors of these materials were calculated from the calculated attenuation coefficients and buildup factors. The shielding factors of the wall, window, roof and floor were calculated separately by settling the model houses and combining the shielding factors of the building materials used, and then the shielding factor of the whole building was obtained by use of the opening fraction of the wall and the fractions of the wall, roof and floor areas to the total floor area. The influence of the shielding effect of the building is well represented by the occupancy factor which is the ratio of the group doses including that shielding effect to those excluding it. The occupancy factor lies between 0.9 and 1.0 for four specified districts, Tokyo, Osaka, Ibaraki and Nagano. (author)

  16. Iron Oxide Nanoparticle Agglomeration Influences Dose-Rates and Modulates Oxidative Stress Mediated Dose-Response Profiles In Vitro

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Gaurav; Kodali, Vamsi K.; Gaffrey, Matthew J.; Wang, Wei; Minard, Kevin R.; Karin, Norman J.; Teeguarden, Justin G.; Thrall, Brian D.

    2013-07-31

    Spontaneous agglomeration of engineered nanoparticles (ENPs) is a common problem in cell culture media which can confound interpretation of in vitro nanotoxicity studies. The authors created stable agglomerates of iron oxide nanoparticles (IONPs) in conventional culture medium, which varied in hydrodynamic size (276 nm-1.5 μm) but were composed of identical primary particles with similar surface potentials and protein coatings. Studies using C10 lung epithelial cells show that the dose rate effects of agglomeration can be substantial, varying by over an order of magnitude difference in cellular dose in some cases. Quantification by magnetic particle detection showed that small agglomerates of carboxylated IONPs induced greater cytotoxicity and redox-regulated gene expression when compared with large agglomerates on an equivalent total cellular IONP mass dose basis, whereas agglomerates of amine-modified IONPs failed to induce cytotoxicity or redox-regulated gene expression despite delivery of similar cellular doses. Dosimetry modelling and experimental measurements reveal that on a delivered surface area basis, large and small agglomerates of carboxylated IONPs have similar inherent potency for the generation of ROS, induction of stress-related genes and eventual cytotoxicity. The results suggest that reactive moieties on the agglomerate surface are more efficient in catalysing cellular ROS production than molecules buried within the agglomerate core. Because of the dynamic, size and density-dependent nature of ENP delivery to cells in vitro, the biological consequences of agglomeration are not discernible from static measures of exposure concentration (μg/ml) alone, highlighting the central importance of integrated physical characterisation and quantitative dosimetry for in vitro studies. The combined experimental and computational approach provides a quantitative framework for evaluating relationships between the biocompatibility of nanoparticles and their

  17. Influence of variations in dose and dose rates on biological effects of inhaled beta-emitting radionuclides

    International Nuclear Information System (INIS)

    McClellan, R.O.; Benjamin, S.A.; Boecker, B.B.; Hahn, F.F.; Hobbs, C.H.; Jones, R.K.; Lundgren, D.L.

    1976-01-01

    The biological effects of inhaled β-emitting radionuclides, 90 Y, 91 Y, 144 Ce and 90 Sr, are being investigated in beagle dogs that received single acute exposures at 12 to 14 months of age. The aerosols studied have included 91 YC1 3 , 144 CeC1 3 , 90 SrC1 2 , and 90 Y, 91 Y, 144 Ce or 90 Sr in aluminosilicate particles. Thus, 91 YCl 3 , 144 CeCl 3 and the aluminosilicate containing radionuclide particles all resulted in significant exposures to lung; 91 YC1 3 , 144 CeC1 3 an 90 SrC1 2 resulted in significant exposures to bone; 91 YC1 3 and 144 CeC1 3 resulted in significant exposures to liver. The higher initial doserate exposures have been more effective than low dose-rate exposures on a per-rad basis in producing early effects. To date ( 144 CeO 2 , it was observed that, on a μCi initial lung burden per kilogram body weight basis, mice did not develop pulmonary tumours whereas beagle dogs did. To fid out the reason for this observation mice have been repeatedly exposed by inhalation to 144 CeO 2 to maintain lung burdens of 144 Ce that resulted in radiation dose rates similar to that observed in beagle dogs. Several of the repeatedly exposed mice developed malignant pulmonary tumours. Thus, with similar dose rates and cumulative doses to the lung, mice and dogs responded in a similar manner to chronic β radiation

  18. Genetic influence on methadone treatment outcomes in patients undergoing methadone maintenance treatment for opioid addiction: a pilot study

    Directory of Open Access Journals (Sweden)

    Samaan Z

    2014-08-01

    Full Text Available Zainab Samaan,1–4 Monica Bawor,3,4 Brittany B Dennis,2,3 Carolyn Plater,5 Michael Varenbut,5 Jeffrey Daiter,5 Andrew Worster,5,6 David C Marsh,5,7 Charlie Tan,8 Dipika Desai,3 Lehana Thabane,2,9,10 Guillaume Pare11 1Department of Psychiatry and Behavioural Neurosciences, 2Department of Clinical Epidemiology and Biostatistics, 3Population Genomics Program, Chanchlani Research Centre, 4MiNDS Neuroscience Program, McMaster University, Hamilton, Ontario, Canada; 5Ontario Addiction Treatment Centres, Richmond Hill, Ontario, Canada; 6Department of Medicine, McMaster University, Hamilton, Ontario, Canada; 7Northern Ontario School of Medicine, Laurentian University, Sudbury, Ontario, Canada; 8Michael G. DeGroote School of Medicine, McMaster University, 9Biostatistics Unit, Centre for Evaluation of Medicine, 10System Linked Research Unit, 11Department of Pathology and Molecular Medicine, McMaster University, Hamilton, Ontario, Canada Introduction: Treatment of opioid addiction with methadone is effective; however, it is known to produce interindividual variability. This may be influenced in part by genetic variants, which can increase the initial risk of developing opioid addiction as well as explain differences in response to treatment. This pilot study aimed to assess the feasibility of conducting a full-scale genetic analysis to identify genes that predict methadone treatment outcomes in this population. Methods: This was a cross-sectional observational study of patients admitted to a methadone maintenance treatment program for opioid addiction. We obtained demographic and clinical characteristics in addition to blood and urine samples, for the assessment of treatment outcomes. Results: The recruitment process yielded 252 patients, representing a 20% recruitment rate. We conducted genetic testing based on a 99.6% rate of provision of DNA samples. The average retention in treatment was 3.4 years, and >50% of the participants reported psychiatric and

  19. Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose

    International Nuclear Information System (INIS)

    Schuring, Danny; Hurkmans, Coen W

    2008-01-01

    To investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs. For 26 patients with stage-I NSCLC treatment plans were optimized with unit density (UD), an equivalent pathlength algorithm (EPL), and a collapsed-cone (CC) algorithm, prescribing 60 Gy to the PTV. After optimization the first two plans were recalculated with the more accurate CC algorithm. Dose parameters were compared for the three different optimized plans. Dose to the target and OARs was evaluated for the recalculated plans and compared with the planned values. For the CC algorithm dose constraints for the ratio of the 50% isodose volume and the PTV, and the V 20 Gy are harder to fulfill. After recalculation of the UD and EPL plans large variations in the dose to the PTV were observed. For the unit density plans, the dose to the PTV varied from 42.1 to 63.4 Gy for individual patients. The EPL plans all overestimated the PTV dose (average 48.0 Gy). For the lungs, the recalculated V 20 Gy was highly correlated to the planned value, and was 12% higher for the UD plans (R 2 = 0.99), and 15% lower for the EPL plans (R 2 = 0.96). Inhomogeneity corrections have a large influence on the dose delivered to the PTV and OARs for SBRT of lung tumors. A simple rescaling of the dose to the PTV is not possible, implicating that accurate dose calculations are necessary for these treatment plans in order to prevent large discrepancies between planned and actually delivered doses to individual patients

  20. Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose

    Directory of Open Access Journals (Sweden)

    Hurkmans Coen W

    2008-07-01

    Full Text Available Abstract Purpose To investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs. Materials and methods For 26 patients with stage-I NSCLC treatment plans were optimized with unit density (UD, an equivalent pathlength algorithm (EPL, and a collapsed-cone (CC algorithm, prescribing 60 Gy to the PTV. After optimization the first two plans were recalculated with the more accurate CC algorithm. Dose parameters were compared for the three different optimized plans. Dose to the target and OARs was evaluated for the recalculated plans and compared with the planned values. Results For the CC algorithm dose constraints for the ratio of the 50% isodose volume and the PTV, and the V20 Gy are harder to fulfill. After recalculation of the UD and EPL plans large variations in the dose to the PTV were observed. For the unit density plans, the dose to the PTV varied from 42.1 to 63.4 Gy for individual patients. The EPL plans all overestimated the PTV dose (average 48.0 Gy. For the lungs, the recalculated V20 Gy was highly correlated to the planned value, and was 12% higher for the UD plans (R2 = 0.99, and 15% lower for the EPL plans (R2 = 0.96. Conclusion Inhomogeneity corrections have a large influence on the dose delivered to the PTV and OARs for SBRT of lung tumors. A simple rescaling of the dose to the PTV is not possible, implicating that accurate dose calculations are necessary for these treatment plans in order to prevent large discrepancies between planned and actually delivered doses to individual patients.

  1. Prednisolone dose-dependently influences inflammation and coagulation during human endotoxemia

    NARCIS (Netherlands)

    de Kruif, Martijn D.; Lemaire, Lucienne C.; Giebelen, Ida A.; van Zoelen, Marieke A. D.; Pater, Jennie M.; van den Pangaart, Petra S.; Groot, Angelique P.; de Vos, Alex F.; Elliott, Peter J.; Meijers, Joost C. M.; Levi, Marcel; van der Poll, Tom

    2007-01-01

    The effects of steroids on the outcome of sepsis are dose dependent. Low doses appear to be beneficial, but high doses do not improve outcome for reasons that are insufficiently understood. The effects of steroids on systemic inflammation as a function of dose have not previously been studied in

  2. Experimental determination of foetal doses received during conventional X rays explorations of troncus. Influence of the lead apron

    International Nuclear Information System (INIS)

    Pifarre, X.; Brualla, L.; Ruiz, J.; Escalada, C.; Planes, D.; Paredes, M.C.

    2001-01-01

    The aim of this paper is to assess the real doses received by pregnant women during some X rays conventional explorations of thorax and abdomen. The procedure that has been used is the measurement of doses by the use of thermoluminescent dosimeters located on the uterus position of a Random Phantom, and simulating different conventional X rays explorations. The results of such measurements are compared with other data published in ICRP 34, which were our reference. We have obtained smaller doses with the measurements than those derived from ICRP 34. The causes of these differences are analysed. The influence of the use of lead apron to protect abdomen during thorax examination is also analysed, computing the real value of this protection. We conclude that it seems interesting to obtain measurements of theses doses with our own equipment and techniques, because it offers a more realistic approximation to real doses received by patients. (author)

  3. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study

    International Nuclear Information System (INIS)

    Kim, Hyungjin; Park, Chang Min; Song, Yong Sub; Lee, Sang Min; Goo, Jin Mo

    2014-01-01

    Purpose: To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. Materials and methods: CT scans were performed on a chest phantom containing various nodules (10 and 12 mm; +100, −630 and −800 HU) at 120 kVp with tube current–time settings of 10, 20, 50, and 100 mAs. Each CT was reconstructed using filtered back projection (FBP), iDose 4 and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Results: Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p > 0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose 4 at all radiation dose settings (p < 0.05). Conclusion: Semi-automated nodule volumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility

  4. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungjin, E-mail: khj.snuh@gmail.com [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Park, Chang Min, E-mail: cmpark@radiol.snu.ac.kr [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Song, Yong Sub, E-mail: terasong@gmail.com [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Lee, Sang Min, E-mail: sangmin.lee.md@gmail.com [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Goo, Jin Mo, E-mail: jmgoo@plaza.snu.ac.kr [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of)

    2014-05-15

    Purpose: To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. Materials and methods: CT scans were performed on a chest phantom containing various nodules (10 and 12 mm; +100, −630 and −800 HU) at 120 kVp with tube current–time settings of 10, 20, 50, and 100 mAs. Each CT was reconstructed using filtered back projection (FBP), iDose{sup 4} and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Results: Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p > 0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose{sup 4} at all radiation dose settings (p < 0.05). Conclusion: Semi-automated nodule volumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility.

  5. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.

    Science.gov (United States)

    Kim, Hyungjin; Park, Chang Min; Song, Yong Sub; Lee, Sang Min; Goo, Jin Mo

    2014-05-01

    To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. CT scans were performed on a chest phantom containing various nodules (10 and 12mm; +100, -630 and -800HU) at 120kVp with tube current-time settings of 10, 20, 50, and 100mAs. Each CT was reconstructed using filtered back projection (FBP), iDose(4) and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p>0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose(4) at all radiation dose settings (pvolumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Adiponectin influences progesterone production from MA-10 Leydig cells in a dose-dependent manner.

    Science.gov (United States)

    Landry, David; Paré, Aurélie; Jean, Stéphanie; Martin, Luc J

    2015-04-01

    Obesity in men is associated with lower testosterone levels, related to reduced sperm concentration and the development of various diseases with aging. Hormones produced by the adipose tissue may have influences on both metabolism and reproductive function. Among them, the production and secretion of adiponectin is inversely correlated to total body fat. Adiponectin receptors (AdipoR1 and AdipoR2) have been found to be expressed in testicular Leydig cells (producing testosterone). Since StAR and Cyp11a1 are essential for testosterone synthesis and adiponectin has been shown to regulate StAR mRNA in swine granulosa cells, we hypothesized that adiponectin might also regulate these genes in Leydig cells. Our objective was to determine whether adiponectin regulates StAR and Cyp11a1 genes in Leydig cells and to better define its mechanisms of action. Methods used in the current study are qPCR for the mRNA levels, transfections for promoter activities, and enzyme-linked immunosorbent assay for the progesterone concentration. We have found that adiponectin cooperates with cAMP-dependent stimulation to activate StAR and Cyp11a1 mRNA expressions in a dose-dependent manner in MA-10 Leydig cells as demonstrated by transfection of a luciferase reporter plasmid. These results led to a significant increase in progesterone production from MA-10 cells. Thus, our data suggest that high doses of adiponectin typical of normal body weight may promote testosterone production from Leydig cells.

  7. Changes in pulmonary function and influencing factors after high-dose intrathoracic radio(chemo)therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Christina [University Clinic Giessen and Marburg, Clinic for Radiotherapy and Radiation Oncology, Marburg (Germany); Ruppiner Kliniken GmbH, Clinic for Radiotherapy and Radiation Oncology, Neuruppin (Germany); Engenhart-Cabillic, Rita; Vorwerk, Hilke [University Clinic Giessen and Marburg, Clinic for Radiotherapy and Radiation Oncology, Marburg (Germany); Schmidt, Michael; Huhnt, Winfried; Blank, Eyck; Sidow, Dietrich; Buchali, Andre [Ruppiner Kliniken GmbH, Clinic for Radiotherapy and Radiation Oncology, Neuruppin (Germany)

    2017-02-15

    Using prospectively collected patient-related, dose-related, and pulmonary function test (PFT) data before radiotherapy (RT) and at several follow-up visits after RT, the time course of PFT changes after high-dose radio(chemo)therapy and influencing factors were analyzed. From April 2012 to October 2015, 81 patients with non-small-cell lung carcinoma (NSCLC), small cell lung carcinoma (SCLC), or esophageal carcinoma where treated with high-dose radio(chemo)therapy. PFT data were collected before treatment and 6 weeks, 12 weeks, and 6 months after RT. The influence of patient- and treatment-related factors on PFT was analyzed. Mean forced expiratory volume in 1 s (FEV1) constantly declined during follow-up (p = 0.001). In total, 68% of patients had a reduced FEV1 at 6 months. Mean vital capacity (VC) didn't change during follow-up (p > 0.05). Mean total lung capacity (TLC) showed a constant decline after RT (p = 0.026). At 6 months, 60% of patients showed a decline in VC and 73% in TLC. The mean diffusion capacity for carbon monoxide (DLCO) declined at 6 and 12 weeks, but recovered slightly at 6 months (p < 0.0005). At 6 months, 86% of patients had a reduced DLCO. After treatment, the partial pressure of CO{sub 2} in the blood (pCO{sub 2}) was increased and pO{sub 2} was decreased (p > 0.05). Only the pretreatment PFT classification had a significant influence on the post-RT FEV1. DLCO seems to be the most reliable indicator for lung tissue damage after thoracic RT. Ventilation parameters appear to be less reliable. Concerning patient- or treatment-related factors, no reliable conclusion can be drawn regarding which factors may be relevant. (orig.) [German] Patientenbezogene, therapiebezogene und Lungenfunktionsdaten (''pulmonary function test'', PFT) wurden vor Radiotherapie (RT) und an verschiedenen Nachsorgeterminen nach RT prospektiv gesammelt, um PFT-Veraenderungen sowie Einflussfaktoren nach Hochdosis-Radio(chemo)therapie zu

  8. Maintenance methods

    International Nuclear Information System (INIS)

    Sanchis, H.; Aucher, P.

    1990-01-01

    The maintenance method applied at the Hague is summarized. The method was developed in order to solve problems relating to: the different specialist fields, the need for homogeneity in the maintenance work, the equipment diversity, the increase of the materials used at the Hague's new facilities. The aim of the method is to create a knowhow formalism, to facilitate maintenance, to ensure the running of the operations and to improve the estimation of the maintenance cost. One of the method's difficulties is the demonstration of the profitability of the maintenance operations [fr

  9. Memory Retrieval Has a Dynamic Influence on the Maintenance Mechanisms That Are Sensitive to ζ-Inhibitory Peptide (ZIP).

    Science.gov (United States)

    Levitan, David; Fortis-Santiago, Yaihara; Figueroa, Joshua A; Reid, Emily E; Yoshida, Takashi; Barry, Nicholas C; Russo, Abigail; Katz, Donald B

    2016-10-12

    In neuroscientists' attempts to understand the long-term storage of memory, topics of particular importance and interest are the cellular and system mechanisms of maintenance (e.g., those sensitive to ζ-inhibitory peptide, ZIP) and those induced by memory retrieval (i.e., reconsolidation). Much is known about each of these processes in isolation, but less is known concerning how they interact. It is known that ZIP sensitivity and memory retrieval share at least some molecular targets (e.g., recycling α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid, AMPA, receptors to the plasma membrane); conversely, the fact that sensitivity to ZIP emerges only after consolidation ends suggests that consolidation (and by extension reconsolidation) and maintenance might be mutually exclusive processes, the onset of one canceling the other. Here, we use conditioned taste aversion (CTA) in rats, a cortically dependent learning paradigm, to test this hypothesis. First, we demonstrate that ZIP infusions into gustatory cortex begin interfering with CTA memory 43-45 h after memory acquisition-after consolidation ends. Next, we show that a retrieval trial administered after this time point interrupts the ability of ZIP to induce amnesia and that ZIP's ability to induce amnesia is reengaged only 45 h after retrieval. This pattern of results suggests that memory retrieval and ZIP-sensitive maintenance mechanisms are mutually exclusive and that the progression from one to the other are similar after acquisition and retrieval. They also reveal concrete differences between ZIP-sensitive mechanisms induced by acquisition and retrieval: the latency with which ZIP-sensitive mechanisms are expressed differ for the two processes. Memory retrieval and the molecular mechanisms that are sensitive to ζ-inhibitory peptide (ZIP) are the few manipulations that have been shown to effect memory maintenance. Although much is known about their effect on maintenance separately, it is unknown how they

  10. A simple method to calculate the influence of dose inhomogeneity and fractionation in normal tissue complication probability evaluation

    International Nuclear Information System (INIS)

    Begnozzi, L.; Gentile, F.P.; Di Nallo, A.M.; Chiatti, L.; Zicari, C.; Consorti, R.; Benassi, M.

    1994-01-01

    Since volumetric dose distributions are available with 3-dimensional radiotherapy treatment planning they can be used in statistical evaluation of response to radiation. This report presents a method to calculate the influence of dose inhomogeneity and fractionation in normal tissue complication probability evaluation. The mathematical expression for the calculation of normal tissue complication probability has been derived combining the Lyman model with the histogram reduction method of Kutcher et al. and using the normalized total dose (NTD) instead of the total dose. The fitting of published tolerance data, in case of homogeneous or partial brain irradiation, has been considered. For the same total or partial volume homogeneous irradiation of the brain, curves of normal tissue complication probability have been calculated with fraction size of 1.5 Gy and of 3 Gy instead of 2 Gy, to show the influence of fraction size. The influence of dose distribution inhomogeneity and α/β value has also been simulated: Considering α/β=1.6 Gy or α/β=4.1 Gy for kidney clinical nephritis, the calculated curves of normal tissue complication probability are shown. Combining NTD calculations and histogram reduction techniques, normal tissue complication probability can be estimated taking into account the most relevant contributing factors, including the volume effect. (orig.) [de

  11. The study of Influencing Maintenance Factors on Failures of Two gypsum Kilns by Failure Modes and Effects Analysis (FMEA

    Directory of Open Access Journals (Sweden)

    Iraj Alimohammadi

    2014-06-01

    Full Text Available Developing technology and using equipment in Iranian industries caused that maintenance system would be more important to use. Using proper management techniques not only increase the performance of production system but also reduce the failures and costs. The aim of this study was to determine the quality of maintenance system and the effects of its components on failures of kilns in two gypsum production companies using Failure Modes and Effects Analysis (FMEA. Furthermore the costs of failures were studied. After the study of gypsum production steps in the factories, FMEA was conducted by the determination of analysis insight, information gathering, making list of kilns’ component and filling up the FMEA’s tables. The effects of failures on production, how to fail, failure rate, failure severity, and control measures were studied. The evaluation of maintenance system was studied by a check list including questions related to system components. The costs of failures were determined by refer in accounting notebooks and interview with the head of accounting department. It was found the total qualities of maintenance system in NO.1 was more than NO.2 but because of lower quality of NO.1’s kiln design, number of failures and their costs were more. In addition it was determined that repair costs in NO.2’s kiln were about one third of NO.1’s. The low severity failures caused the most costs in comparison to the moderate and low ones. The technical characteristics of kilns were appeared to be the most important factors in reducing of failures and costs.

  12. Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns.

    Science.gov (United States)

    Delben, Juliana Aparecida; Barão, Valentim Adelino Ricardo; Dos Santos, Paulo Henrique; Assunção, Wirley Gonçalves

    2014-02-01

    The effect of veneering materials on screw joint stability remains inconclusive. Thus, this study evaluated the preload maintenance of abutment screws of single crowns fabricated with different abutments and veneering materials. Sixty crowns were divided into five groups (n = 12): UCLA abutment in gold alloy with ceramic (group GC) and resin (group GR) veneering, UCLA abutment in titanium with ceramic (group TiC) and resin (group TiR) veneering, and zirconia abutment with ceramic veneering (group ZiC). Abutment screws made of gold were used with a 35 Ncm insertion torque. Detorque measurements were obtained initially and after mechanical cycling. Data were analyzed by ANOVA and Fisher's exact test at a significance level of 5%. For the initial detorque means (in Ncm), group TiC (21.4 ± 1.78) exhibited statistically lower torque maintenance than groups GC (23.9 ± 0.91), GR (24.1 ± 1.34), and TiR (23.2 ± 1.33) (p abutment type and veneering material. More irregular surfaces in the hexagon area of the castable abutments were observed. The superiority of any veneering material concerning preload maintenance was not established. © 2013 by the American College of Prosthodontists.

  13. A Human Error Analysis Procedure for Identifying Potential Error Modes and Influencing Factors for Test and Maintenance Activities

    International Nuclear Information System (INIS)

    Kim, Jae Whan; Park, Jin Kyun

    2010-01-01

    Periodic or non-periodic test and maintenance (T and M) activities in large, complex systems such as nuclear power plants (NPPs) are essential for sustaining stable and safe operation of the systems. On the other hand, it also has been raised that human erroneous actions that might occur during T and M activities has the possibility of incurring unplanned reactor trips (RTs) or power derate, making safety-related systems unavailable, or making the reliability of components degraded. Contribution of human errors during normal and abnormal activities of NPPs to the unplanned RTs is known to be about 20% of the total events. This paper introduces a procedure for predictively analyzing human error potentials when maintenance personnel perform T and M tasks based on a work procedure or their work plan. This procedure helps plant maintenance team prepare for plausible human errors. The procedure to be introduced is focusing on the recurrent error forms (or modes) in execution-based errors such as wrong object, omission, too little, and wrong action

  14. Influence of Neutron Spectra Unfolding Method on Fast Neutron Dose Determination

    International Nuclear Information System (INIS)

    Marinkovic, P.

    1991-01-01

    Full text: Accuracy of knowing the fast neutron spectra has great influence on equivalent dose determination. In usual fast neutron spectrum measurements with scintillation detectors based on proton recoil, the main difficulty is confidence of unfolding method. In former ones variance of obtained result is usually great and negative values are possible too, which does means that we don't now exactly is obtained neutron spectrum real one. The new unfolding method based on Shanon's information theory, which gives non-negative spectrum and relative low variance, is obtained and appropriate numerical code for application in fast neutron spectrometry based on proton recoil is realized. In this method principle of maximum entropy and maximum likelihood are used together. Unknown group density distribution functions, which are considered as desired normalized mean neutron group flux, are constl u cted using only constrain of knowing mean value. Obtained distributions are consistent to available information (counts in NCA from proton recoil), while being maximally noncommittal with respect to all other unknown circumstances. For maximum likelihood principle, distribution functions around mean value of counts in the channels of MCA are taken to be Gauss function shape. Optimal non-negative solution is searched by means of Lagrange parameter method. Nonlinear system of equations, is solved using gradient and Newton iterative algorithm. Error covariance matrix is obtained too. (author)

  15. Influence of phantom and tube voltage in fluoroscopy on image intensifier (I.I.) incident dose rate

    International Nuclear Information System (INIS)

    Seguchi, Shigenobu; Ishikawa, Yoshinobu; Kuwahara, Kazuyoshi; Morita, Miki; Mizuno, Shouta; Nakamura, Akio

    1999-01-01

    We examined the influence of phantoms and tube voltage in fluoroscopy on the image intensifier (I.I.) conversion factor. We used 20-cm-thick acrylic resin, 20 mm aluminum, and 1.5 mm copper, which are generally used as phantoms in the measurement of I.I. incident dose rate. We measured I.I. incident dose rate and conversion factor under conditions in which the range of tube voltage was from 60 kV to 120 kV. The result showed that the conversion factor is influenced by the type of phantom, with copper showing the highest value, aluminum second, and acrylic the smallest under the same condition of aluminum at half value layer. It was determined that conversion factor depends on tube voltage and has peaks from 80-100 kV. The location and height of the peak are influenced by the type of phantom. Therefore, I.I. incident dose rate is influenced by both the type of phantom and tube voltage under automatic brightness control fluoroscopy. Unification of phantoms and tube voltage is necessary for long-term evaluation of I.I. incident dose rate. (author)

  16. Influence of duration and dose of metformin on cobalamin deficiency in type 2 diabetes patients using metformin

    NARCIS (Netherlands)

    Beulens, Joline W J; Hart, Huberta E.; Kuijs, Ron; Kooijman-Buiting, Antoinette M J; Rutten, Guy E H M

    2015-01-01

    Metformin use is associated with cobalamin (vitamin B12) deficiency. However, the influence of both duration and dose of metformin is unclear. Studies using holotranscobalamin, a marker for cellular cobalamin deficiency, are scarce. We therefore investigated the prevalence of cobalamin deficiency in

  17. Influence of dose reduction and iterative reconstruction on CT calcium scores : a multi-manufacturer dynamic phantom study

    NARCIS (Netherlands)

    van der Werf, N R; Willemink, M J; Willems, T P; Greuter, M J W; Leiner, T

    To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s

  18. Adaptive designs for dose-finding in non-cancer phase II trials: influence of early unexpected outcomes.

    Science.gov (United States)

    Resche-Rigon, Matthieu; Zohar, Sarah; Chevret, Sylvie

    2008-01-01

    In non-cancer phase II trials, dose-finding trials are usually carried out using fixed designs, in which several doses including a placebo are randomly distributed to patients. However, in certain vulnerable populations, such as neonates or infants, there is an heightened requirement for safety, precluding randomization. To estimate the minimum effective dose of a new drug from a non-cancer phase II trial, we propose the use of adaptive designs like the Continual Reassessment Method (CRM). This approach estimates the dose closest to some target response, and has been shown to be unbiased and efficient in cancer phase I trials. Based on a motivating example, we point out the individual influence of first outliers in this setting. A weighted version of the CRM is proposed as a theoretical benchmark to control for these outliers. Using simulations, we illustrate how this approach provides further insight into the behavior of the CRM. When dealing with low targets like a 10% failure rate, the CRM appears unable to rapidly overcome an early unexpected outcome. This behavior persisted despite changing the inference (Bayesian or likelihood), underlying dose-response model (though slightly improved using the power model), and the number of patients enrolled at each dose level. The choices for initial guesses of failure rates, the vague prior for the model parameter, and the log-log shape of weights can appear somewhat arbitrary. In phase II dose-finding studies in which failure targets are below 20%, the CRM appears quite sensitive to first unexpected outcomes. Using a power model for dose-response improves some behavior if the trial is started at the first dose level and includes at least three to five patients at the starting dose before applying the CRM allocation rule.

  19. Comparison of biophysical factors influencing on emphysema quantification with low-dose CT

    Science.gov (United States)

    Heo, Chang Yong; Kim, Jong Hyo

    2014-03-01

    Emphysema Index(EI) measurements in MDCT is known to be influenced by various biophysical factors such as total lung volume, and body size. We investigated the association of the four biophysical factors with emphysema index in low-dose MDCT. In particular, we attempted to identify a potentially stronger biophysical factor than total lung volume. A total of 400 low-dose MDCT volumes taken at 120kVp, 40mAs, 1mm thickness, and B30f reconstruction kernel were used. The lungs, airways, and pulmonary vessels were automatically segmented, and two Emphysema Indices, relative area below -950HU(RA950) and 15th percentile(Perc15), were extracted from the segmented lungs. The biophysical factors such as total lung volume(TLV), mode of lung attenuation(ModLA), effective body diameter(EBD), and the water equivalent body diameter(WBD) were estimated from the segmented lung and body area. The association of biophysical factors with emphysema indices were evaluated by correlation coefficients. The mean emphysema indices were 8.3±5.5(%) in RA950, and -930±18(HU) in Perc15. The estimates of biophysical factors were 4.7±1.0(L) in TLV, -901±21(HU) in ModLA, 26.9±2.2(cm) in EBD, and 25.9±2.6(cm) in WBD. The correlation coefficients of biophysical factors with RA950 were 0.73 in TLV, 0.94 in ModLA, 0.31 in EBD, and 0.18 WBD, the ones with Perc15 were 0.74 in TLV, 0.98 in ModLA, 0.29 in EBD, and 0.15 WBD. Study results revealed that two biophysical factors, TLV and ModLA, mostly affects the emphysema indices. In particular, the ModLA exhibited strongest correlation of 0.98 with Perc15, which indicating the ModLA is the most significant confounding biophysical factor in emphysema indices measurement.

  20. The influence of split doses of γ-radiation on human erythrocytes

    International Nuclear Information System (INIS)

    Koziczak, R.; Gonciarz, M.; Krokosz, A.; Szweda-Lewandowska, Z.

    2003-01-01

    Human erythrocyte suspensions in an isotonic Na-phosphate buffer, pH 7.4, of hematocrit of 2% were exposed under air to gamma radiation at a dose rate of 2.2 kGy. Erythrocytes were irradiated with single doses, and identical doses split into two fractions with an interval time of 3.5 h between following exposures. The obtained results indicated that the irradiation of enucleated human erythrocytes with split doses caused a reduction of hemolysis (2.4 times), a decrease in the level of damage to membrane lipids and the contents of MetHb, compared with identical single doses. However, the splitting of radiation doses did not change the level of damage to the membrane proteins, as was estimated with a maleimide spin label. The obtained results suggest that a decrease in the level of damage to lipids was related to a decrease in hemolysis. (author)

  1. Influence of dose-time relationship on the pathogenesis of peripheral neuropathy

    International Nuclear Information System (INIS)

    Kogelnik, H.D.; Vienna Univ.

    1977-01-01

    The development of peripheral neutopathies of cranial nerves and of the brachial plexus following curative doses of irradiation is closely related with the total dose applied, the number and size of the individual doses per fraction and the overall time. Additional important factors for the occurrence of these late complications are the volume of tissue irradiated and the stage of disease. In the pathogenesis of peripheral neuropathy a combined effect of different factors seems likely. (orig.) [de

  2. Evaluation of the influence of weather conditions on external dose rate

    International Nuclear Information System (INIS)

    Knight, A.

    1993-01-01

    Six time periods in 1989/90, when there were high gamma ray dose rate readings at three or more RIMNET Phase 1 sites, were selected for detailed study. The high dose rates were compared with meteorological data (rainfall, temperatures, windspeeds and atmospheric pressure) at the sites for the time periods studied. The results using daily and hourly data clearly show a correlation between gamma ray dose rate and rainfall but not with the other meteorological parameters studied. The increase in dose rate with increased rainfall is believed to be due to radon decay products being washed down with heavy rain. (author)

  3. The influence of radiation of different doses on biometrical indicators of cucumber

    International Nuclear Information System (INIS)

    Gasanov, S.P.; Guseynova, M.Z.; Gulieva, L.M.; Alieva, M.I.; Eminova, N.M.

    2013-01-01

    As it is known, pre-irradiation of plant seeds is usually applied to improve the productivity of crops. Irradiation of seeds at low doses usually does not cause adverse effects. However, irradiation of seeds with higher doses leads to complete loss of cell division ability. In many cases, the morphological change of the primary leaves, and the observed inhibition of the development to such an extent that the plants are deprived of fruiting abilities. The obtained data shows that with increasing of irradiation dose these parameters decrease, at high radiation doses clearly inhibits development of the fruit

  4. Influence of Exercise Intensity for Improving Depressed Mood in Depression: A Dose-Response Study.

    Science.gov (United States)

    Meyer, Jacob D; Koltyn, Kelli F; Stegner, Aaron J; Kim, Jee-Seon; Cook, Dane B

    2016-07-01

    Exercise effectively improves mood in major depressive disorder (MDD), but the optimal exercise stimulus to improve depressed mood is unknown. To determine the dose-response relationship of acute exercise intensity with depressed mood responses to exercise in MDD. We hypothesized that the acute response to exercise would differ between light, moderate, and hard intensity exercise with higher intensities yielding more beneficial responses. Once weekly, 24 women (age: 38.6±14.0) diagnosed with MDD underwent a 30-minute session at one of three steady-state exercise intensities (light, moderate, hard; rating of perceived exertion 11, 13 or 15) or quiet rest on a stationary bicycle. Depressed mood was evaluated with the Profile of Mood States before, 10 and 30 minutes post-exercise. Exercise reduced depressed mood 10 and 30 minutes following exercise, but this effect was not influenced by exercise intensity. Participants not currently taking antidepressants (n=10) had higher baseline depression scores, but did not demonstrate a different antidepressant response to exercise compared to those taking antidepressants. To acutely improve depressed mood, exercise of any intensity significantly improved feelings of depression with no differential effect following light, moderate, or hard exercise. Pharmacological antidepressant usage did not limit the mood-enhancing effect of acute exercise. Acute exercise should be used as a symptom management tool to improve mood in depression, with even light exercise an effective recommendation. These results need to be replicated and extended to other components of exercise prescription (e.g., duration, frequency, mode) to optimize exercise guidelines for improving depression. Copyright © 2016. Published by Elsevier Ltd.

  5. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  6. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  7. Influence of the dose rate on the proliferation capacity of haematopoietic elementary cells in vivo after partial body irradiation

    International Nuclear Information System (INIS)

    Sauer, R.

    1977-01-01

    During direct irradiation of the bone marrow, the dose rate effect was so paradoxical that a temporally protracted exposure has a stronger influence on the proliferation capacity of the elementary cells than one with high dose performance. During the recreation process, the elementary cells proliferated in the sense of a rebound-phaenomenon. This was also referred to the observation that in the non-irradiated bone marrow of animals exposed to partial body irradiation, an activation of the elementary cells started. The results have consequences for the oncological radiotherapy. (orig.) [de

  8. Influence of bone and fat on dose distribution in electron beams in a semi-infinite medium

    International Nuclear Information System (INIS)

    Sordo, A.

    1983-12-01

    Hitherto, physical and theoretical aspects of the influence of heterogeneities in radiotherapy by electron beams had not been enough considered. We have developped an experimental method which permitted us to analyze the effect of the hard bone and the fat on the depth dose distributions when an infinite medium is irradiated by high energy electron beams. We have incorporated the KR. HOGSTROM's algorithm in a treatment planning system (TP11; AECL). This algorithm sums the dose distribution of individual pencil beams. A comparison between calculated and measured isodose lines obtained in a heterogeneous medium, shows us the performance and limits of this algorithm [fr

  9. Preventative Maintenance.

    Science.gov (United States)

    Migliorino, James

    Boards of education must be convinced that spending money up front for preventive maintenance will, in the long run, save districts' tax dollars. A good program of preventive maintenance can minimize disruption of service; reduce repair costs, energy consumption, and overtime; improve labor productivity and system equipment reliability; handle…

  10. Skin dose rate conversion factors after contamination with radiopharmaceuticals: influence of contamination area, epidermal thickness and percutaneous absorption

    International Nuclear Information System (INIS)

    Covens, P; Berus, D; Caveliers, V; Struelens, L; Vanhavere, F; Verellen, D

    2013-01-01

    Skin contamination with radiopharmaceuticals can occur during biomedical research and daily nuclear medicine practice as a result of accidental spills, after contact with bodily fluids of patients or by inattentively touching contaminated materials. Skin dose assessment should be carried out by repeated quantification to map the course of the contamination together with the use of appropriate skin dose rate conversion factors. Contamination is generally characterised by local spots on the palmar surface of the hand and complete decontamination is difficult as a result of percutaneous absorption. This specific issue requires special consideration as to the skin dose rate conversion factors as a measure for the absorbed dose rate to the basal layer of the epidermis. In this work we used Monte Carlo simulations to study the influence of the contamination area, the epidermal thickness and the percutaneous absorption on the absorbed skin dose rate conversion factors for a set of 39 medical radionuclides. The results show that the absorbed dose to the basal layer of the epidermis can differ by up to two orders of magnitude from the operational quantity H p (0.07) when using an appropriate epidermal thickness in combination with the effect of percutaneous absorption. (paper)

  11. Influence of γ-radiation doses on the properties of TeOx: (x=2-3) thin film

    International Nuclear Information System (INIS)

    Dewan, Namrata; Sreenivas, K.; Gupta, Vinay

    2007-01-01

    The influence of γ-ray doses (10-50 Gy) on the optical and electrical properties of radio-frequency sputtered tellurium dioxide (TeO x ) thin film was studied. The composition of the as-deposited TeO x films deposited under 25% oxygen and 100% oxygen in the sputtering gas mixture (Ar+O 2 ) was x=2 and 3, respectively. TeO 3 films were found to be highly sensitive to the γ-radiation doses and the value of optical band gap decrease from 4.18 to 3.56 eV with increasing radiation dose from 10 to 50 Gy. Current-voltage characteristics of the films showed an increase in the value of conductivity with increasing radiation doses. Monotonic decrease in the values of dielectric constant for the deposited films with increase in radiation dose was observed. The effect of γ-ray doses on the properties of TeO x film has been correlated with the rearrangement of the bipyramidal structure of amorphous TeO x thin film

  12. Investigation of the influence of the working procedure on patient dose in angiography of the lower limbs

    International Nuclear Information System (INIS)

    Struelens, L.; Vanhavere, F.; Bosmans, H.

    2002-01-01

    This document presents dose measurements on patients in the field of interventional angiography. We have restricted this study to a common IR procedure, namely diagnostic angiography of the lower limbs. In this examination, radiographs are made over 6 adjoining standard regions from abdomen to feet. The RX tube is moved from one region to another under fluoroscopic guidance. To visualise the arteries, contrast media is injected through a catheter that has been inserted in the abdominal artery. The positioning of the catheter is also controlled by fluoroscopy. Only typical procedures (without medical complications) in male and female patients were considered in this study. Within the scope of the optimisation of patient doses, we looked for the influence of both the working procedure and the exposure parameters on patient dose. Examinations as performed by different operators and in different hospitals were included in the study. The effective dose E is calculated with the use of calculated derived conversion factors, which link practical dose measurements under well-defined conditions with estimates of the effective dose. Measurements in 4 different hospitals, 2 university hospitals and 2 peripheral hospitals are compared

  13. Dose and effect relationship of radiation induced cancer and its influencing factors in experimental animals, 1

    International Nuclear Information System (INIS)

    Sasaki, Shunsaku; Sato, Fumiaki; Eto, Hideo

    1975-01-01

    The data of risk evaluation of external irradiation were integrated with animal experiments from the aspects of qualitative generalizations of characteristics of radiation induced tumors. Studies covered competition of cause of death, figure of dose-to-effect relationship, characteristics of low dose rate of irradiation, relative biological effectiveness (RBE) of high LET radiation, effects of feactionated irradiation, complex actions with chemical substances, effects of protectional medium, differences of radiosensitivity by species and strains, and age dependency of sensitivities. Competition of cause of death by time length of latent period and degree of malignancy of the disease. Discussion on competition of death suggested the following idea: 1) incidence of tumor induction in the individual level did not correspond to transformation in the cellular level, and 2) relative incidence of tumor induction after a certain dose of whole body irradiation did not indicate the relative sensitivity of each tissue, for the relationship between tumor incidence and exposure dose was not a linear relationship. The dose-to-effect relationship of tumor induction was decided by following factors: i) sensitivity on transformation of cells, ii) sensitivity on the death of potential tumor cells, and iii) competition of the cause of death. Tumor induction by low dose rate irradiation was also studied by comparing qualitative and quantitative differences between high dose rate single irradiation and a series of low dose rate irradiation. (Serizawa, K.)

  14. Influence of the dosing process on the rheological and microstructural properties of a bakery product

    NARCIS (Netherlands)

    Baixauli, R.; Sanz, T.; Salvador, A.; Fisman, S.M.

    2007-01-01

    This study examined the effect of the use of an automatic dosing unit on the rheological, microstructural, and textural properties of an aerated batter for preparing a bakery product. Two cases were studied: in one the batter was dosed manually into the paper cups and in the other the batter was

  15. In vivo tissue heterogeneity influence on dose distributhon in high energy radiotheraphy with x ray

    International Nuclear Information System (INIS)

    Aldred, M.A.

    1987-01-01

    In vivo effects of tissue heterogeneity of pelvic region on dose distribution are studied. Eight patients under radiotherapy with linear accelerator are analysed. Thermoluminescent dosimeters placed under the skin are used for dose measurements of radiation beams. A comparative evaluation between this study and homogeneneous phantoms is presented. (M.A.C.) [pt

  16. Modelling the Influence of Shielding on Physical and Biological Organ Doses

    CERN Document Server

    Ballarini, Francesca; Ferrari, Alfredo; Ottolenghi, Andrea; Pelliccioni, Maurizio; Scannicchio, Domenico

    2002-01-01

    Distributions of "physical" and "biological" dose in different organs were calculated by coupling the FLUKA MC transport code with a geometrical human phantom inserted into a shielding box of variable shape, thickness and material. While the expression "physical dose" refers to the amount of deposited energy per unit mass (in Gy), "biological dose" was modelled with "Complex Lesions" (CL), clustered DNA strand breaks calculated in a previous work based on "event-by-event" track-structure simulations. The yields of complex lesions per cell and per unit dose were calculated for different radiation types and energies, and integrated into a version of FLUKA modified for this purpose, allowing us to estimate the effects of mixed fields. As an initial test simulation, the phantom was inserted into an aluminium parallelepiped and was isotropically irradiated with 500 MeV protons. Dose distributions were calculated for different values of the shielding thickness. The results were found to be organ-dependent. In most ...

  17. An open-label, sequential, dose-finding study of peginesatide for the maintenance treatment of anemia in chronic hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Besarab Anatole

    2012-08-01

    Full Text Available Abstract Background Peginesatide is a peptide-based erythropoiesis-stimulating agent that was designed and engineered to stimulate specifically the erythropoietin receptor dimer that governs erythropoiesis. The primary objective of this phase 2 dose-finding study was to determine the once-monthly peginesatide dosing strategy that would maintain hemoglobin within ±1.0 g/dL of baseline values after conversion from epoetin alfa; the safety of peginesatide was evaluated concurrently. Methods Chronic hemodialysis patients on stable regimens of epoetin alfa were sequentially assigned to cohorts that differed on (1 how the peginesatide starting dose was determined (using a single epoetin alfa–to-peginesatide dose conversion ratio or a tiered, weight-based or absolute-dose conversion table and on (2 whether or not a 1-week erythropoiesis-stimulating agent-free interval was used. Peginesatide doses were titrated to maintain hemoglobin levels within ±1.0 g/dL from baseline. Results A total of 164 patients were enrolled and received intravenous peginesatide every 4 weeks for up to 6 doses; the duration of the study including follow-up was ≤29 weeks. Overall, the proportion of patients with hemoglobin levels within ±1.0 g/dL of baseline increased over the course of the study from 39% (Weeks 2–13 to 54% (Weeks 18–25. Cohorts that used tiered dose conversion tables trended towards having more stable peginesatide doses than did those cohorts that used a single dose conversion ratio. Moreover, cohorts that used an erythropoiesis-stimulating agent-free interval did not have the substantial initial increase in hemoglobin levels that was seen in those cohorts that did not use such an interval. In this study, the safety profile of peginesatide was consistent with those of marketed erythropoiesis-stimulating agents. Conclusions The results of this study were used to guide the dosing regimens used subsequently in phase 3 studies. Once

  18. Influence of dose on particle size of colloidal silver nanoparticles synthesized by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Naghavi, Kazem, E-mail: Kazem.naghavi@gmail.co [Universiti Putra Malaysia, Physics Department, 43400 UPM SERDANG, Selangor (Malaysia); Saion, Elias [Universiti Putra Malaysia, Physics Department, 43400 UPM SERDANG, Selangor (Malaysia); Rezaee, Khadijeh [Department of Nuclear Engineering, Faculty of Modern Sciences and Technologies, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Yunus, Wan Mahmood Mat [Universiti Putra Malaysia, Physics Department, 43400 UPM SERDANG, Selangor (Malaysia)

    2010-12-15

    Colloidal silver nanoparticles were synthesized by {gamma}-irradiation-induced reduction method of an aqueous solution containing silver nitrate as a precursor in various concentrations between 7.40x10{sup -4} and 1.84x10{sup -3} M, polyvinyl pyrrolidone for capping colloidal nanoparticles, isopropanol as radical scavenger of hydroxyl radicals and deionised water as a solvent. The irradiations were carried out in a {sup 60}Co {gamma} source chamber at doses up to 70 kGy. The optical absorption spectra were measured using UV-vis spectrophotometer and used to study the particle distribution and electronic structure of silver nanoparticles. As the radiation dose increases from 10 to 70 kGy, the absorption intensity increases with increasing dose. The absorption peak {lambda}{sub max} blue shifted from 410 to 403 nm correspond to the increase of absorption conduction electron energy from 3.02 to 3.08 eV, indicating the particle size decreases with increasing dose. The particle size was determined by photon cross correlation spectroscopy and the results showed that the particle diameter decreases exponentially with the increase of dose. The transmission electron microscopy images were taken at doses of 20 and 60 kGy and the results confirmed that as the dose increases the diameter of colloidal silver nanoparticle decreases and the particle distribution increases.

  19. The influence of dose per fraction on the pathogenesis of radiation nephropathy

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, F.; Atahan, I.L.; Tuncel, M.; Konan, A. [Hacettepe University, Faculty of Medicine, Ankara (Turkey). Departments of Radiation Oncology and Anatomy

    1998-11-01

    Both kidneys of male Wistar rats were irradiated with either a 1 0-Gy single dose or 26 Gy at a rate of 2 Gy per fraction per day. Serum blood urea nitrogen (BUN), creatinine and blood haematocrit levels were assessed prior to radiotherapy and at intervals of 8 weeks thereafter. A subset of animals from each dose group were killed at 4, 8,16 and 24 weeks and both kidneys of each animal were examined by electron microscopy. In both dose groups a significant increase in BUN and creatinine levels, together with a decrease in haematocrit level, was observed at 16 weeks, and this was followed by an apparent improvement at 24 weeks. There was no statistical difference in these responses between the two groups. The morphological changes in both dose groups were essentially similar, but differed in severity. At 4 weeks after irradiation glomerular and proximal tubular injury were observed in both groups. A marked increase of glomerular and tubular injury in the 10-Gy dose group, without any apparent progression in the 26-Gy dose group, was detected at 8 weeks. By 16 weeks a noticeable improvement in both tubular and glomerular lesions (especially in the 10-Gy dose group) was observed. No apparent difference from the 16th week of evaluation was found at 24 weeks. These findings indicate that there is some recovery in kidney after irradiation, but the extent of the recovery process is somewhat limited. Copyright (1998) Blackwell Science Pty Ltd 38 refs., 1 tab., 4 figs.

  20. Influence of dose on particle size of colloidal silver nanoparticles synthesized by gamma radiation

    International Nuclear Information System (INIS)

    Naghavi, Kazem; Saion, Elias; Rezaee, Khadijeh; Yunus, Wan Mahmood Mat

    2010-01-01

    Colloidal silver nanoparticles were synthesized by γ-irradiation-induced reduction method of an aqueous solution containing silver nitrate as a precursor in various concentrations between 7.40x10 -4 and 1.84x10 -3 M, polyvinyl pyrrolidone for capping colloidal nanoparticles, isopropanol as radical scavenger of hydroxyl radicals and deionised water as a solvent. The irradiations were carried out in a 60 Co γ source chamber at doses up to 70 kGy. The optical absorption spectra were measured using UV-vis spectrophotometer and used to study the particle distribution and electronic structure of silver nanoparticles. As the radiation dose increases from 10 to 70 kGy, the absorption intensity increases with increasing dose. The absorption peak λ max blue shifted from 410 to 403 nm correspond to the increase of absorption conduction electron energy from 3.02 to 3.08 eV, indicating the particle size decreases with increasing dose. The particle size was determined by photon cross correlation spectroscopy and the results showed that the particle diameter decreases exponentially with the increase of dose. The transmission electron microscopy images were taken at doses of 20 and 60 kGy and the results confirmed that as the dose increases the diameter of colloidal silver nanoparticle decreases and the particle distribution increases.

  1. Electron arc therapy: Influence of heterogeneities on dose to blood-forming organs

    International Nuclear Information System (INIS)

    Leavitt, D.D.; Gibbs, F.A.; Moeller, J.H.

    1986-01-01

    Electron arc therapy has been used successfully to treat extended chest wall surfaces after mastectomy. Treatment is frequently given simultaneously with chemotherapy. Although the primary electron arc treatment volume consists only of the chest wall and mediastinum, dose is accumulated at the isocenter of rotation due to the photon contamination of the arcing electron beam. Additionally, higher energy electron fields which are occasionally used over segments of the arc may contribute to the dose at isocenter if the electron range has been extended due to passage through a low-density heterogeneity such as lung. In some patient setups, the isocenter may intersect blood-forming organs, such as the vertebral bodies. Thermoluminescent dosimetry has been used to measure the dose at isocenter for the following setups: polystyrene phantom, polystyrene phantom covered by 1-cm-thick lead cast, polystyrene phantom with cork insert to simulate lung, and phantom plus cork insert plus lead cast. For the 9-MeV treatment mode, dose at isocenter per 90 0 of arc (as a percentage of maximum tumor dose) is as follows: phantom, 6.5%; phantom plus lead, 5%; phantom plus cork, 8%; and phantom plus cork plus lead, 6%. These values must be scaled by the size of the arc to estimate dose at isocenter in actual treatments. Computer calculation showed good agreement with these measured values, indicating that the computerized treatment plans can be used as a predictor of electron arc dose to blood-forming organs

  2. Skin dose from radiotherapy X-ray beams: the influence of energy

    International Nuclear Information System (INIS)

    Butson, M.J.; Metcalfe, P.E.; University of Wollongong, Wollongong, NSW; Mathur, J.N.

    1997-01-01

    Skin-sparing properties of megavoltage photon beams are compromised by electron contamination. Higher energy beams do not necessarily produce lower surface and basal cell layer doses due to this electron contamination. For a 5x5 cm field size the surface doses for 6 MVp and 18 M)p X-ray beams are 10% and 7% of their respective maxima. However, at a field size of 40 x 40cm the percentage surface dose is 42% for both 6 MVp and 18 MVp beams. The introduction of beam modifying devices such as block trays can further reduce the skin-sparing advantages of high energy photon beams. Using a 10 mm perspex block tray, the surface doses for 6 MVp and 18 MVp beams with a 5 x 5 cm field size are 10% and 8%, respectively. At 40 x 40cm, surface doses are 61% and 63% for 6 MVp and 18 MVp beams, respectively. This trend is followed at the basal cell layer depth. At a depth of 1 mm, 18 MVp beam doses are always at least 5% smaller than 6 MVp doses for the same depth at all field sizes when normalized to their respective Dmax values. Results have shown that higher energy photon beams produce a negligible reduction of the delivered dose to the basal cell layer (0.1 mm). Only a small increase in skin sparing is seen at the dermal layer (1 mm), which can be negated by the increased exit dose from an opposing field. (authors)

  3. Influence of a transverse magnetic field on the dose deposited by a 6 MV linear accelerator

    Directory of Open Access Journals (Sweden)

    Richter Sebastian

    2017-09-01

    Full Text Available An integrated system of a linear accelerator and a magnetic resonance imaging (MRI device may provide real-time imaging during radiotherapy treatments. This work investigated changes affecting the dose deposition caused by a magnetic field (B-field transverse to the beam direction by means of Monte Carlo simulations. Two different phantoms were used: A water phantom (Ph1 and a water-air phantom (Ph2 with a 4-2-4 cm water-air-water cross section. Dose depositions were scored for B-field values of 0 T, 0.35 T, 0.5 T, 1.5 T, 3 T and 5 T. Beams were based on a precalculated photon spectrum taken from an earlier simulated Elekta 6 MV FFF accelerator. All lateral profiles in Ph1 showed a Lorentz force driven shift w.r.t. the B-field strength, presenting a steeper penumbra in the shift's direction. Depositions were shifted up to 0.3 cm for 5 T, showing a constant central axis plateau-dose or an increase by 2.3 % for small fields. Depth-dose curves in Ph1 showed a shift of the dose maximum towards the beam entrance direction for increasing B-field of up to 1.1 cm; the maximum dose was increased by 6.9 %. In Ph2, an asymmetric dose increase by up to 36.9 % was observed for 1.5 T at the water-air boundary, resulting from the electron return effect (ERE. In our scenario, B-field dependent dose shifts and local build-ups were observed, which consequently affect the resulting dose distribution and need to be considered in magnetic resonance guided radiotherapy treatment planning.

  4. In vivo study on influence of the heterogeneity of tissues in the dose distribution in high energy X ray therapy

    International Nuclear Information System (INIS)

    Aldred, M.A.

    1987-01-01

    Several authors investigated the effect of the heterogeneity of tissue in the dose distribution in a radiation-therapy. Practically all of them carried out ''in vitro'' measurements using a solid body immersed in a water phantom, in order to simulate the inhomogeneity, such as bone, air cavity, etc. In the present work, ''in vivo'' measurements were performed utilizing thermoluminescent dosimeters, whose appropriateness and convenience are well known. Eight patients at Instituto de Radioterapia Oswaldo Cruz were selected, that were under irradiation treatments in their pelvic region. The ratio between body entry radiation dose and the corresponding exit dose, when compared to the same ratio for a homogeneous phantom, gives the influence of the heterogeneity of the tissue the radiation crosses. The results found in those eight patients have shown that ''in vivo'' measurements present a ratio about 8% smaller that in homogeneous phantom case. (author) [pt

  5. SU-E-T-324: The Influence of Patient Positioning Uncertainties in Proton Radiotherapy On Proton Range and Dose Distributions

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, J [EBG MedAustron GmbH, Wiener Neustadt (Austria); Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Medical University of Graz, Graz (Austria); Paganetti, H; Winey, B [Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States)

    2014-06-01

    Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: 38 clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50% and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs) and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: We identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 mm and 5.8 mm for the 90%-dose falloff position respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. TCP decreases larger than 10% (absolute) were seen for less than 2.2% of the target volumes or non-existent. EUD changes were up to 178% for OARs and 35% for target volumes. Conclusion: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain and target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple compensator

  6. Cytosolic calcium ions exert a major influence on the firing rate and maintenance of pacemaker activity in guinea-pig sinus node.

    Directory of Open Access Journals (Sweden)

    Rebecca Anne Capel

    2015-02-01

    Full Text Available The sino-atrial node (SAN provides the electrical stimulus to initiate every heart beat. Cellular processes underlying this activity have been debated extensively, especially with regards to the role of intracellular calcium. We have used whole-cell application of 1,2-bis(o-aminophenoxyethane-N,N,N',N'-tetraacetic acid (BAPTA, a rapid calcium chelator, to guinea pig isolated SAN myocytes to assess the effect of rapid reduction of intracellular calcium on SAN cell electrical activity. High-dose (10 mM BAPTA induced rapid and complete cessation of rhythmic action potential (AP firing (time to cessation 5.5±1.7 s. Over a range of concentrations, BAPTA induced slowing of action potential firing and disruption of rhythmic activity, which was dose-dependent in its time of onset. Exposure to BAPTA was associated with stereotyped action potential changes similar to those previously reported in the presence of ryanodine, namely depolarisation of the most negative diastolic potential, prolongation of action potentials and a reduction in action potential amplitude. These experiments are consistent with the view that cytosolic calcium is essential to the maintenance of rhythmic pacemaker activity.

  7. The influence of dose distribution on treatment outcome in the SCOPE 1 oesophageal cancer trial

    International Nuclear Information System (INIS)

    Carrington, Rhys; Spezi, Emiliano; Gwynne, Sarah; Dutton, Peter; Hurt, Chris; Staffurth, John; Crosby, Thomas

    2016-01-01

    The first aim of this study was to assess plan quality using a conformity index (CI) and analyse its influence on patient outcome. The second aim was to identify whether clinical and technological factors including planning treatment volume (PTV) volume and treatment delivery method could be related to the CI value. By extending the original concept of the mean distance to conformity (MDC) index, the OverMDC and UnderMDC of the 95 % isodose line (50Gy prescribed dose) to the PTV was calculated for 97 patients from the UK SCOPE 1 trial (ISCRT47718479). Data preparation was carried out in CERR, with Kaplan-Meier and multivariate analysis undertaken in EUCLID and further tests in Microsoft Excel and IBM’s SPSS. A statistically significant breakpoint in the overall survival data, independent of cetuximab, was found with OverMDC (4.4 mm, p < 0.05). This was not the case with UnderMDC. There was a statistically significant difference in PTV volume either side of the OverMDC breakpoint (Mann Whitney p < 0.001) and in OverMDC value dependent on the treatment delivery method (mean IMRT = 2.1 mm, mean 3D-CRT = 4.1 mm Mann Whitney p < 0.001). Re-planning the worst performing patients according to OverMDC from 3D-CRT to VMAT resulted in a mean reduction in OverMDC of 2.8 mm (1.6–4.0 mm). OverMDC was not significant in multivariate analysis that included age, sex, staging, tumour type, and position. Although not significant when included in multivariate analysis, we have shown in univariate analysis that a patient’s OverMDC is correlated with overall survival. OverMDC is strongly related to IMRT and to a lesser extent with PTV volume. We recommend that VMAT planning should be used for oesophageal planning when available and that attention should be paid to the conformity of the 95 % to the PTV

  8. Influence of low- and high-dose radioiodine therapy on oxidative modification of fibrinogen

    International Nuclear Information System (INIS)

    Schweeger-Exeli, I.J.

    2001-10-01

    levels were significantly elevated above 300 mg/dl (p 0.05) and did not change to a significant extent after treatment in both subgroups. Conclusion: Purification of fibrinogen out of small volumes of plasma is feasible in a short period of time and requires only little technical effort. High - dose radioiodine therapy, applied in differentiated thyroid cancer, leads to significantly increased incorporation of carbonyl groups into the fibrinogen molecule. It remains to be elucidated, whether thyroid hormone status itself influences oxidative damage of fibrinogen. Key words: fibrinogen; radioiodine therapy; oxidative modification; isolation techniques; 2,4-dinitrophenylhydrazine. (author)

  9. Factors influencing changes in levels of radiation doses received by patients during gastroduodenal series procedures in the Hospital Dr. Max Peralta de Cartago

    International Nuclear Information System (INIS)

    Guzman Campos, Jeremy; Vargas Navarro, Jonnathan

    2009-01-01

    A measurement was made of the number of radiation doses emitted by fluoroscopy equipment used in Hospital Dr. Max Peralta, specifically at the Centro de Deteccion de Cancer Gastrico. The analysis has included the factors could be influencing on increase of the total dose to the patient, by means of indicators that directly affect the unnecessary increase in dose, such as: the procedure, sequences of images, indicators of dosage levels, varying conditions of actual studies, variations dose levels and production process factors. [es

  10. The influence of geology on terrestrial gamma radiation dose rate in Pahang state, Malaysia

    International Nuclear Information System (INIS)

    Gabdo, H.T.; Ramli, A.T.; Sanusi, M.S.; Garba, N.N.; Saleh, M.A.

    2015-01-01

    Terrestrial gamma radiation dose (TGRD) rate measurements have been made in Pahang state, Malaysia. Significant variations were found between TGRD measurements and the underlying geological formations. In some cases revealing significant elevations of TGRD. The acid-intrusive geological formation has the highest mean TGRD measurement of 367 nGy/h -1 . This is more than six times the world average value of 59 nGy/h -1 , while the quaternary geological formation has the lowest mean gamma radiation dose rate of 99 nGy h -1 . The annual effective dose equivalent outdoor to the population was 0.216 mSv. The lifetime equivalent dose and relative lifetime cancer risks for an individual living in Pahang state were 81 mSv and 4.7 x 10 -3 respectively. These values are more than two times the world average of 34 mSv and 1.95 x 10 -3 respectively. (author)

  11. Influence of genetic polymorphisms on the effect of high- and standard-dose clopidogrel after percutaneous coronary intervention: the GIFT (Genotype Information and Functional Testing) study.

    Science.gov (United States)

    Price, Matthew J; Murray, Sarah S; Angiolillo, Dominick J; Lillie, Elizabeth; Smith, Erin N; Tisch, Rebecca L; Schork, Nicholas J; Teirstein, Paul S; Topol, Eric J

    2012-05-29

    This study sought to evaluate the influence of single nucleotide polymorphisms (SNPs) on the pharmacodynamic effect of high- or standard-dose clopidogrel after percutaneous coronary intervention (PCI). There is a lack of prospective, multicenter data regarding the effect of different genetic variants on clopidogrel pharmacodynamics over time in patients undergoing PCI. The GRAVITAS (Gauging Responsiveness with A VerifyNow assay-Impact on Thrombosis And Safety) trial screened patients with platelet function testing after PCI and randomly assigned those with high on-treatment reactivity (OTR) to either high- or standard-dose clopidogrel; a cohort of patients without high OTR were also followed. DNA samples obtained from 1,028 patients were genotyped for 41 SNPs in 17 genes related to platelet reactivity. After adjusting for clinical characteristics, the associations between the SNPs and OTR using linear regression were evaluated. CYP2C19*2 was significantly associated with OTR at 12 to 24 h (R(2) = 0.07, p = 2.2 × 10(-15)), 30 days (R(2) = 0.10, p = 1.3 × 10(-7)), and 6 months after PCI (R(2) = 0.07, p = 1.9 × 10(-11)), whereas PON1, ABCB1 3435 C→T, and other candidate SNPs were not. Carriers of 1 and 2 reduced-function CYP2C19 alleles were significantly more likely to display persistently high OTR at 30 days and 6 months, irrespective of treatment assignment. The portion of the risk of persistently high OTR at 30 days attributable to reduced-function CYP2C19 allele carriage was 5.2% in the patients randomly assigned to high-dose clopidogrel. CYP2C19, but not PON1 or ABCB1, is a significant determinant of the pharmacodynamic effects of clopidogrel, both early and late after PCI. In patients with high OTR identified by platelet function testing, the CYP2C19 genotype provides limited incremental information regarding the risk of persistently high reactivity with clopidogrel 150-mg maintenance dosing. (Genotype Information and Functional Testing Study [GIFT]; NCT

  12. Study of distribution of doses in maintenance operations and interventions in restricted areas of IPEN's radiopharmacy center, Brazil; Estudo da distribuicao de doses em operacoes de manutencao e intervencao em areas restritas no Centro de Radiofarmacia do IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Jessica S.; Souza, Daiane C.; Rodrigues Junior, Orlando; Gerulis, Eduardo; Todo, Alberto S., E-mail: jsmachado@ipen.br, E-mail: dcsouza@ipen.br, E-mail: rodrijr@ipen.br, E-mail: egerulis@ipen.br, E-mail: astodo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (lPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    This research was developed at the Radiopharmacy Center of the Nuclear and Energy Research Institute - IPEN/CNEN/SP, Brazil, that performs the production of radiopharmaceuticals with isotopes of the {sup 131}I, {sup 123}I, {sup 201}Tl, {sup 67}Ga, {sup 18}F and {sup 99}Mo for use in nuclear medicine. The radioisotopes are produced on an industrial scale and the installation was designed to meet radiation safety standards and quality control requirements. To ensure the production, there are skilled professionals who perform the tasks of maintenance of the equipment and instruments, installed in the cells of processing of radiopharmaceuticals, without which it is not possible to conduct the work with safety and quality. This study was done a survey called Survey of Variables, based on the maintenance operations and interventions in restricted areas of the Centre of Radiopharmacy and in the survey of the distribution of doses in these tasks, carried out during the period from 2005 to 2011. This research aims to identify and determine the main variables that have an impact on the worker's dose. The results are presented for the Occupationally Exposed Individual variable, variable operation, variable area/Cell, task and Feature variable and variable duration of operation, depending on the Dose variable. It is intended in this way to contribute to improvements in operations in restricted areas that may result in lower individual doses without causing significant changes in the routine of work.

  13. Influence of low dose irradiation on differentiation, maturation and T-cell activation of human dendritic cells

    Energy Technology Data Exchange (ETDEWEB)

    Jahns, Jutta [Department of Radiotherapy and Radiation Oncology, University of Leipzig, Stephanstrasse 21, 04103 Leipzig (Germany); Anderegg, Ulf; Saalbach, Anja [Department for Dermatology, Venerology and Allergology, University of Leipzig, Johannisallee 30, 04103 Leipzig (Germany); Rosin, Britt; Patties, Ina; Glasow, Annegret [Department of Radiotherapy and Radiation Oncology, University of Leipzig, Stephanstrasse 21, 04103 Leipzig (Germany); Kamprad, Manja [Institute for Clinical Immunology and Transfusion Medicine, University of Leipzig, Johannisallee 30, 04103 Leipzig (Germany); Scholz, Markus [Institute for Medical Informatics, Statistics and Epidemiology, University of Leipzig, Haertelstr. 16-18, 04103 Leipzig (Germany); Hildebrandt, Guido, E-mail: Guido.Hildebrandt@uni-rostock.de [Department of Radiotherapy and Radiation Oncology, University of Rostock, Suedring 75, 18059 Rostock (Germany); Department of Radiotherapy and Radiation Oncology, University of Leipzig, Stephanstrasse 21, 04103 Leipzig (Germany)

    2011-05-10

    Ionizing irradiation could act directly on immune cells and may induce bystander effects mediated by soluble factors that are released by the irradiated cells. This is the first study analyzing both the direct effect of low dose ionizing radiation (LDIR) on the maturation and cytokine release of human dendritic cells (DCs) and the functional consequences for co-cultured T-cells. We showed that irradiation of DC-precursors in vitro does not influence surface marker expression or cytokine profile of immature DCs nor of mature DCs after LPS treatment. There was no difference of single dose irradiation versus fractionated irradiation protocols on the behavior of the mature DCs. Further, the low dose irradiation did not change the capacity of the DCs to stimulate T-cell proliferation. But the irradiation of the co-culture of DCs and T-cells revealed significantly lower proliferation of T-cells with higher doses. Summarizing the data from approx. 50 DC preparations there is no significant effect of low dose ionizing irradiation on the cytokine profile, surface marker expression and maturation of DCs in vitro although functional consequences cannot be excluded.

  14. Maintenance Mentor

    National Research Council Canada - National Science Library

    Jacobs, John

    2003-01-01

    Maintenance Mentor (MXM) is a research effort conducted by a joint AFRL/HESR and Northrop Grumman Information Technology team to identify the basic, high-level requirements necessary for improving flight line diagnostic capabilities...

  15. Influence on dose calculation by difference of dose calculation algorithms in stereotactic lung irradiation. Comparison of pencil beam convolution (inhomogeneity correction: batho power law) and analytical anisotropic algorithm

    International Nuclear Information System (INIS)

    Tachibana, Masayuki; Noguchi, Yoshitaka; Fukunaga, Jyunichi; Hirano, Naomi; Yoshidome, Satoshi; Hirose, Takaaki

    2009-01-01

    The monitor unit (MU) was calculated by pencil beam convolution (inhomogeneity correction algorithm: batho power law) [PBC (BPL)] which is the dose calculation algorithm based on measurement in the past in the stereotactic lung irradiation study. The recalculation was done by analytical anisotropic algorithm (AAA), which is the dose calculation algorithm based on theory data. The MU calculated by PBC (BPL) and AAA was compared for each field. In the result of the comparison of 1031 fields in 136 cases, the MU calculated by PBC (BPL) was about 2% smaller than that calculated by AAA. This depends on whether one does the calculation concerning the extension of the second electrons. In particular, the difference in the MU is influenced by the X-ray energy. With the same X-ray energy, when the irradiation field size is small, the lung pass length is long, the lung pass length percentage is large, and the CT value of the lung is low, and the difference of MU is increased. (author)

  16. THE INFLUENCE OF LANGUAGE USE AND LANGUAGE ATTITUDE ON THE MAINTENANCE OF COMMUNITY LANGUAGES SPOKEN BY MIGRANT STUDENTS

    Directory of Open Access Journals (Sweden)

    Leni Amalia Suek

    2014-05-01

    Full Text Available The maintenance of community languages of migrant students is heavily determined by language use and language attitudes. The superiority of a dominant language over a community language contributes to attitudes of migrant students toward their native languages. When they perceive their native languages as unimportant language, they will reduce the frequency of using that language even though at home domain. Solutions provided for a problem of maintaining community languages should be related to language use and attitudes of community languages, which are developed mostly in two important domains, school and family. Hence, the valorization of community language should be promoted not only in family but also school domains. Several programs such as community language school and community language program can be used for migrant students to practice and use their native languages. Since educational resources such as class session, teachers and government support are limited; family plays significant roles to stimulate positive attitudes toward community language and also to develop the use of native languages.

  17. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  18. Whole brain radiotherapy for brain metastases: The technique of irradiation influences the dose to parotid glands

    International Nuclear Information System (INIS)

    Loos, G.; Paulon, R.; Verrelle, P.; Lapeyre, M.

    2012-01-01

    In the treatment of brain metastases, whole brain radiotherapy can be carried out according two distinct methods: one using multi-leaf collimator for field shaping and protection of organs at risk, and a second one is to make a rotation of the field to avoid the eyes. The aim of the study was to compare for 10 patients the dose distributions at organs at risk for each method. Patients received 30 Gy in 10 fractions. Except for parotid glands, the dose received by organs at risk and the planning target volume was the same with each method. For whole brain radiotherapy, excluding the cisterna cerebellomedullaris, the mean parotid dose was 9.63 Gy using the multi-leaf collimator versus 12.32 Gy using the field rotation (P = 0.04). For whole brain radiotherapy including the cisterna cerebellomedullaris, the mean parotid dose was 11.12 Gy using the multi-leaf collimator versus 20.06 Gy using field rotation (P < 0.001). Using the multi-leaf collimator seems recommended for whole brain radiotherapy, to reduce the dose to the parotids. (authors)

  19. Influence on the individual dose by using lead aprons at hemodynamic services

    International Nuclear Information System (INIS)

    Alonso, Thessa Cristina; Silva, Teogenes Augusto da

    2005-01-01

    In interventional radiology, heart catheterism procedures are done with therapeutic and diagnosis purposes. In those medical practices, staff members are required to wear lead aprons for individual protection beside other protective equipment like thyroid lead protector, lead eyeglasses and gloves. The proper and suitable equipment is chosen according to the exam type. Exposure of medical team is under discussion concerned to use of the individual dosimeter under or on the lead apron and the need to apply a dose correction factor of 0.01 in the first case to estimate the effective dose. This work investigates personal doses of medical team in interventional radiology services of two hospitals in Belo Horizonte. Individual thermoluminescent dosimeters were fastened under and on lead aprons during one month period to measure the personal dose equivalents, Hp(10). Results indicate that the dose correction factor due to the lead apron presence is not a proper correction for interventional radiology exams; different factors are suggested if the worker is closer or not so close the x-ray beam. Additionally, it is emphasized that the use of adequate protective aprons and conscientious behavior according to a safety culture can minimize the radiation exposure of those professionals. (author)

  20. Influence of boundary effects on electron beam dose distribution formation in multilayer targets

    International Nuclear Information System (INIS)

    Kaluska, I.; Zimek, Z.; Lazurik, V.T.; Lazurik, V.M.; Popov, G.F.; Rogov, Y.V.

    2010-01-01

    Computational dosimetry play a significant role in an industrial radiation processing at dose measurements in the product irradiated with electron beams (EB), X-ray and gamma ray from radionuclide sources. Accurate and validated programs for absorbed dose calculations are required for computational dosimetry. The program ModeStEB (modelling of EB processing in a three-dimensional (3D) multilayer flat targets) was designed specially for simulation and optimization of industrial radiation processing, calculation of the 3D absorbed dose distribution within multilayer packages. The package is irradiated with scanned EB on an industrial radiation facility that is based on the pulsed or continuous type of electron accelerators in the electron energy range from 0.1 to 25 MeV. Simulation of EB dose distributions in the multilayer targets was accomplished using the Monte Carlo (MC) method. Experimental verification of MC simulation prediction for EB dose distribution formation in a stack of plates interleaved with polyvinylchloride (PVC) dosimetric films (DF), within a packing box, and irradiated with a scanned 10 MeV EB on a moving conveyer is discussed. (authors)

  1. Effective dose as an irritating influence during fractionated γ-irradiation

    International Nuclear Information System (INIS)

    Karpov, V.N.; Ushakov, I.B.; Davydov, B.I.

    1990-01-01

    The study of early neurological disturbances (END) in rats after fractionated γ-irradiation with doses of 37.5-225 Gy at dose rate of 30.11 Gy/min has demonstrated that the initial response of animals to pulse ionizing radiation is a function of the electric charge induced by ionizing radiation. A change in the probability of occurrence of each of the END symptoms, with the increased intervals between exposures, is merely an indirect indication of the eliminating mechanisms and is intricately connected with the irritating charge value. The proposed empiric relationships permit to correlate the probability of END symptom occurrence with the continuous quantitative parameter of fractionated irradiation, that is, with an effective dose as an analogue of the irritating effect

  2. The influence of inhomogeneities on the dose distribution of fast electrons in radiotherapy

    International Nuclear Information System (INIS)

    Windemuth, M.

    1985-01-01

    Simple models are used to make a principal comparison between measured fast-electron dose distributions behind tissue inhomogeneities and those calculated by means of an irradiation planning system. The different organs were represented by water (for muscle), by cork (for the lungs) and by graphite (for bone). Corresponding to their density, inhomogeneities result, in principle, in a dose shift to a greater or smaller body depth which is correctly considered by the irradiation planning system. However, electron scattering transversal to beam direction will occur behind inhomogeneity edges which, in general, are not covered by the irradiation planning system, but which result in dose distributions deviating strongly from those expected as due to the shift. This is the reason for the limited accuracy of irradiation planning systems in complicated inhomogeneity distribution. The thesis demonstrates those cases which justify irradiation planning and those cases where they are not a reliable basis for irradiation. (orig./HP) [de

  3. [Influence of low doses of ionizing radiation on tenascin expression in hybridoma cell systems].

    Science.gov (United States)

    Lunga, I N

    2003-01-01

    One of the achievements of the modern radiation ecology is the preparation and application of stable eukariotic cell lines to solve various problems occurring under exposure to ionizing radiation, especially to low doses. The detection of onco-fetal protein--tenascin in different embryonic and tumor cells of humans and animals supposes the probability of appropriate gene expression in lymphoid cells, including hybridomal cells. Using the immunochemical method, the study of tenascin expression in two mouse hybridomal lines was carried out. Tenascin was revealed in hybridomal lines MLC-1 and K-48. Further hybridomal cell lines were exposed to X-ray radiation (120 KV) with doses 2.10,15 cGy. The obtained results demonstrated the sensitivity of tenascin expression to low doses of ionizing radiation, that may be used as a convenient model of studying of genotoxic effects of various damaging ionizing agents on a cell level.

  4. In-group and role identity influences on the initiation and maintenance of students' voluntary attendance at peer study sessions for statistics.

    Science.gov (United States)

    White, Katherine M; O'Connor, Erin L; Hamilton, Kyra

    2011-06-01

    Although class attendance is linked to academic performance, questions remain about what determines students' decisions to attend or miss class. In addition to the constructs of a common decision-making model, the theory of planned behaviour, the present study examined the influence of student role identity and university student (in-group) identification for predicting both the initiation and maintenance of students' attendance at voluntary peer-assisted study sessions in a statistics subject. University students enrolled in a statistics subject were invited to complete a questionnaire at two time points across the academic semester. A total of 79 university students completed questionnaires at the first data collection point, with 46 students completing the questionnaire at the second data collection point. Twice during the semester, students' attitudes, subjective norm, perceived behavioural control, student role identity, in-group identification, and intention to attend study sessions were assessed via on-line questionnaires. Objective measures of class attendance records for each half-semester (or 'term') were obtained. Across both terms, students' attitudes predicted their attendance intentions, with intentions predicting class attendance. Earlier in the semester, in addition to perceived behavioural control, both student role identity and in-group identification predicted students' attendance intentions, with only role identity influencing intentions later in the semester. These findings highlight the possible chronology that different identity influences have in determining students' initial and maintained attendance at voluntary sessions designed to facilitate their learning. ©2010 The British Psychological Society.

  5. Protection of lethally irradiated mice with allogeneic fetal liver cells: influence of irradiation dose on immunologic reconstitution

    International Nuclear Information System (INIS)

    Tulunay, O.; Good, R.A.; Yunis, E.J.

    1975-01-01

    After lethal irradiation long-lived, immunologically vigorous C3Hf mice were produced by treatment with syngeneic fetal liver cells or syngeneic newborn or adult spleen cells. Treatment of lethally irradiated mice with syngeneic or allogeneic newborn thymus cells or allogeneic newborn or adult spleen cells regularly led to fatal secondary disease or graft-versus-host reactions. Treatment of the lethally irradiated mice with fetal liver cells regularly yielded long-lived, immunologically vigorous chimeras. The introduction of the fetal liver cells into the irradiated mice appeared to be followed by development of immunological tolerance of the donor cells. The findings suggest that T-cells at an early stage of differentiation are more susceptible to tolerance induction than are T-lymphocytes at later stages of differentiation. These investigations turned up a perplexing paradox which suggests that high doses of irradiation may injure the thymic stroma, rendering it less capable of supporting certain T-cell populations in the peripheral lymphoid tissue. Alternatively, the higher and not the lower dose of irradiation may have eliminated a host cell not readily derived from fetal liver precursors which represents an important helper cell in certain cell-mediated immune functions, e.g., graft-versus-host reactions, but which is not important in others, e.g., allograft rejections. The higher dose of lethal irradiation did not permit development or maintenance of a population of spleen cells that could initiate graft-versus-host reactions but did permit the development of a population of donor cells capable of achieving vigorous allograft rejection

  6. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

    Science.gov (United States)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-03-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.

  7. Influence of metallic dental implants and metal artefacts on dose calculation accuracy

    International Nuclear Information System (INIS)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-01-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic trademark EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques. (orig.) [de

  8. Budesonide/formoterol maintenance plus reliever therapy

    DEFF Research Database (Denmark)

    Bisgaard, Hans; Le Roux, Pascal; Bjåmer, Ditlef

    2006-01-01

    on ICS investigated whether a novel regimen using budesonide/formoterol for maintenance and reliever therapy (Symbicort maintenance and relief therapy [SMART]) [Symbicort; AstraZeneca R&D, Lund, Sweden] could reduce exacerbations. METHODS: Patients received SMART (budesonide/formoterol 80/4.5 microg qd...... maintenance plus additional inhalations for symptom relief), budesonide/formoterol 80/4.5 microg qd for maintenance (fixed combination), or higher-dose budesonide 320 microg qd (fixed-dose budesonide). Blinded as-needed medication (terbutaline 0.4 microg) was provided in both fixed-dose groups. RESULTS: SMART...... prolonged the time to first exacerbation vs fixed-dose budesonide (p = 0.02) and fixed-dose combination (p SMART vs fixed-dose budesonide and fixed-dose combination (0.08/patient vs 0.28/patient and 0.40/patient...

  9. Boots on the ground: how to influence your local radiology departments to use appropriate CT dose

    International Nuclear Information System (INIS)

    Slovis, Thomas L.

    2014-01-01

    Most pediatric CT examinations (as many as 85%) are performed at non-pediatric-focused facilities. In contrast to children's hospitals and pediatric emergency departments, the number of CT examinations is increasing at these non-pediatric facilities. Compliance with diagnostic reference levels (DRLs) for dose has been shown to be poor at several metropolitan centers. Several high-yield interventions are worth exploring in an effort to achieve more optimal imaging care of children, such as electronic transfer of images to prevent duplication of examinations as well as personal feedback to referring institutions on dose, indications and quality by the pediatric referral center. (orig.)

  10. Influence of thermoluminescence trapping parameter from abundant quartz powder on equivalent dose

    International Nuclear Information System (INIS)

    Zhao Qiuyue; Wei Mingjian; Song Bo; Pan Baolin; Zhou Rui

    2014-01-01

    Glow curves of abundant quartz powder were obtained with the RGD-3B thermoluminescence (TL) reader. TL peaks with 448, 551, 654, 756 K were identified at the heating rate of 5 K/s. The activation energy, frequency factor and lifetime of trapped charge were evaluated at ambient temperature for four peaks by the method of various heating rates. Within a certain range of activation energy, the equivalent dose increases exponentially with the activation energy. The equivalent dose increases from 54 Gy to 485 Gy with the temperature from 548 K to 608 K, and it fluctuates around 531 Gy with the temperature from 608 K to 748 K. (authors)

  11. Boots on the ground: how to influence your local radiology departments to use appropriate CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Slovis, Thomas L. [Wayne State University School of Medicine, Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States)

    2014-10-15

    Most pediatric CT examinations (as many as 85%) are performed at non-pediatric-focused facilities. In contrast to children's hospitals and pediatric emergency departments, the number of CT examinations is increasing at these non-pediatric facilities. Compliance with diagnostic reference levels (DRLs) for dose has been shown to be poor at several metropolitan centers. Several high-yield interventions are worth exploring in an effort to achieve more optimal imaging care of children, such as electronic transfer of images to prevent duplication of examinations as well as personal feedback to referring institutions on dose, indications and quality by the pediatric referral center. (orig.)

  12. Influence of Residual Tumor Volume and Radiation Dose Coverage in Outcomes for Clival Chordoma

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Mark W., E-mail: markmcdonaldmd@gmail.com [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana (United States); Indiana University Health Proton Therapy Center, Bloomington, Indiana (United States); Linton, Okechukwu R. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana (United States); Moore, Michael G.; Ting, Jonathan Y. [Department of Otolaryngology, Head and Neck Surgery, Indiana University School of Medicine, Indianapolis, Indiana (United States); Cohen-Gadol, Aaron A.; Shah, Mitesh V. [Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana (United States); Goodman Campbell Brain and Spine, Indianapolis, Indiana (United States)

    2016-05-01

    Purpose: The purpose of this study was to evaluate factors associated with tumor control in clival chordomas. Methods and Materials: A retrospective review of 39 patients treated with surgery and proton therapy for clival chordomas between 2004 and 2014 was performed. The median prescribed dose was 77.4 Gy (relative biological effectiveness [RBE]); range was 70.2-79.2 Gy (RBE). Minimum and median doses to gross tumor volume (GTV), radiation dose received by 1 cm{sup 3} of GTV (D1cm{sup 3}), and the equivalent uniform dose were calculated. Receiver operating characteristics curves evaluated the predictive sensitivity and specificity for local failure of potential cutpoint values for GTV and D1cm{sup 3}. Results: After a median follow-up of 51 months, the 5-year estimate of local control (LC) was 69.6% (95% confidence interval [CI] 50.0%-89.2%), and overall survival (OS) was 81.4% (95% CI: 65.3%-97.5%). Tumor histology, GTV at the time of radiation, and prescribed radiation dose were significantly associated with local control on multivariate analysis, whereas D1cm{sup 3} was associated with overall survival. Compared to those patients whose conditions remained controlled, patients experiencing tumor failure had statistically significant larger GTVs and lower D1cm{sup 3}, and prescribed and median doses to GTV. A subset of 21 patients with GTV of ≤20 cm{sup 3} and D1cm{sup 3} of >67 Gy (RBE) had a median follow-up of 47 months. The 5-year estimate of local control in this subset was 81.1% (95% CI: 61.7%-100%; P=.004, overall comparison by GTV ≤20 cm{sup 3} stratified by D1cm{sup 3}). A D1cm{sup 3} of 74.5 Gy (RBE) had 80% sensitivity for local control and 60% specificity, whereas a GTV of 9.3 cm{sup 3} had 80% sensitivity for local control and 66.7% specificity. Conclusions: Local control of clival chordomas was associated with both smaller size of residual tumor and more complete high-dose coverage of residual tumor. Multidisciplinary care should seek

  13. Influence of the radio-tracer used in diagnostic nuclear medicine upon the dose at the nucleus of cellular localisation

    International Nuclear Information System (INIS)

    Gardin, I.; Faraggi, M.; Stievenart, J.L; Le Guludec, D.; Bok, B.

    1997-01-01

    In the classical dosimetry one supposes a uniform distribution of the radio-pharmaceuticals at the source organ level as well as a homogeneous distribution of the absorbed dose. This hypotheses are not always verified in biology, and the influence of the tracer localisation on the dose delivered at the cellular nucleus has been studied. The average dose delivered by the electron emission of different radio-isotopes used in diagnosis has been calculated by taking into account the radioactivity localized upon the target cell (Dself), and upon the neighbouring cells (Dcross). Nuclear, cytoplasmic and membranous localizations of the tracer were simulated for different cellular sizes. In the particular case of 99m Tc and cells of nuclear radius about 4 μm and cellular radios about 8 μ, Dcross is independent of the intra-cellular localisation of the tracer. On the contrary, for a nuclear localisation Dself is 52 and 157 times more important than for the cytoplasmic and membranous localisation, respectively. The dose at the cellular nucleus due to electron emission of 99m Tc is under-estimated by a factor 2.6 by classical dosimetry when the radioactivity is nuclear. On the contrary, the classical model over-estimates by a factor 1.2 the dose at nucleus for cytoplasmic and membranous localizations. This study shows that the dose delivered at cellular nucleus by the electron emissions of 99m Tc depends on the localisation of the tracer. The modelling proposed allows a better evaluation of the radiobiological hazards related to the administration of radiopharmaceuticals in diagnostic nuclear medicine

  14. Mechanical configuration and maintenance

    International Nuclear Information System (INIS)

    Brown, T.G.; Casini, G.; Churakov, G.F.

    1982-01-01

    The INTOR engineering design has been strongly influenced by considerations for assembly and maintenance. A maintenance philosophy was established at the outset of the conceptual design to insure that the tokamak configuration would be developed to accommodate maintenance requirements. The main features of the INTOR design are summarized in this paper with primary emphasis on the impact of maintenance considerations. The most apparent configuration design feature is the access provided for torus maintenance. Particular attention was given to the size and location of superconducting magnets and the location of vacuum boundaries. All of the poloidal field (PF) coils are placed outside of the bore of the toroidal field (TF) coils and located above and below an access opening between adjacent TF coils through which torus sectors are removed. A magnet structural configuration consisting of mechanically attached reinforcing members has been designed which facilitates the open access space for torus sector removal. For impurity control, a single null poloidal divertor was selected over a double null design in order to maintain sufficient access for pumping and maintenance of the collector. A double null divertor was found to severely limit access to the torus with the addition of divertor collectors and pumping at the top. For this reason, a single null concept was selected in spite of the more difficult design problems associated with the required asymmetric PF system and higher particle loadings

  15. Influence of different dose irradiation on genetic effect in mice somatic and germ cells

    International Nuclear Information System (INIS)

    Kostrova, L.N.; Molofej, V.P.; Mosseh, I.B.

    2007-01-01

    Comparison of clastogenic effects of different radiation doses in somatic and germ cells of one the same animals has been studied. Correlation analysis allows to extrapolate genetic effects from somatic cells to germ ones. This can be useful for human model elaboration. (authors)

  16. Influence of different doses of octenidine hexafluorosilicate on parodontotium state of rat, which received cariesogenic ration

    Directory of Open Access Journals (Sweden)

    V. Yu. Anisimov

    2017-06-01

    Full Text Available Aim: To determine of parodontium state of rat, which received cariesogenic ration and different doses of octenidine hexafluorosilicate (O-HFS. Methods: The octenidine hexafluorosilicate was synthesized by us and was used into mucoso-adgesive gels (Na-CMC in next concentrations: 1 mg/ml, 2 mg/ml and 4 mg/ml. The rats received high-sugar cariesogenic ration and oral applications of gels with O-HFS in doses of 0,3 ml (daily doses of O-HFS were 1,4 mg/kg, 2,8 mg/kg and 5,6 mg/kg. The duration of experiment was 35 days. The activities of urease, lysozyme and elastase were determined into gum. The activities of urease, lysozyme, ALT and alkaline phosphatase (APh were determined into serum. The degree of dysbiosis calculated by ration urease and lysozyme. The degree of atrophy of parodontale bone was determined by Nicolaeva method. Results: The activities of elastase and urease, the degree of atrophy and dysbiosis were raised into gum of rat, which received cariesogenic ration. The activities of ALT and APh, the degree of dysbiosis were raised into serum. The oral application of O-HFS-gels decreased the all these indices. The maximal action made O-HFS-gel in dose 2,8 mg/kg. Conclusion: The oral application of O-HFS-gel make parodontoprotective action.

  17. On the influence of the electron dose rate on the HRTEM image contrast

    Energy Technology Data Exchange (ETDEWEB)

    Barthel, Juri, E-mail: ju.barthel@fz-juelich.de [RWTH Aachen University, Ahornstraße 55, 52074 Aachen (Germany); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Lentzen, Markus; Thust, Andreas [Peter Grünberg Institute, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany)

    2017-05-15

    We investigate a possible dependence between the applied electron dose-rate and the magnitude of the resulting image contrast in HRTEM of inorganic crystalline objects. The present study is focussed on the question whether electron irradiation can induce excessively strong atom vibrations or displacements, which in turn could significantly reduce the resulting image contrast. For this purpose, high-resolution images of MgO, Ge, and Au samples were acquired with varying dose rates using a C{sub S}-corrected FEI Titan 80–300 microscope operated at 300 kV accelerating voltage. This investigation shows that the magnitude of the signal contrast is independent from the dose rates occurring in conventional HRTEM experiments and that excessively strong vibrations or displacements of bulk atoms are not induced by the applied electron irradiation. - Highlights: • No dependence between electron dose rate and HRTEM image contrast is found. • This finding is in full accordance with established solid-state physics theory. • Object-related causes for the previous Stobbs-factor phenomenon are ruled out.

  18. Geological influence on terrestrial gamma radiation dose rate in the Malaysian State of Johore

    International Nuclear Information System (INIS)

    Ramli, A.T.; Hussein, A.W.M.A.; Lee, M.H.

    2001-01-01

    Measurements of environmental terrestrial gamma radiation dose-rate (TGRD) have been made in Johore, Malaysia. The focus is on determining a relationship between geological type and TGRD levels. Data were compared using the one way analysis of variance (ANOVA), in some instances revealing significant differences between TGRD measurements and the underlying geological structure

  19. Influence of high doses of manganese, copper, zinc and boron on some legumes

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, G

    1973-01-01

    Macroscopic and microscopic examinations showed the following symptoms of an excess in trace elements: (1) High doses of manganese (50-150 ppm) cause dark patches (chloroplast accumulation) in young leaves, and necrosis of the leaf margin (MnO/sub 2/ accumulation) in older leaves. The roots become brown and die off. Roots newly formed in compensation are strikingly light-colored. (2) High doses of copper (5-40 ppm) cause iron deficiency chlorosis. A large number of side roots develop in quick succession as a result of damage to the root apex, so that a thick tangle of roots is formed. (3) High doses of zinc (50-150 ppm) bring about dark green, very brittle young leaves with very high ZnO content. The older leaves become red and then yellow. The roots remain stunted because of inhibited growth in length. (4) High doses of boron (30-90 ppm) cause a leaf necrosis which proceeds in the sequence tip, margin, lamina. The roots are not affected in any characteristic way. They become brown and die off.

  20. Influence of gamma dose rate on longevity of Laemophloeus ferrugineus (STEPH.)

    International Nuclear Information System (INIS)

    Wiendl, F.M.; Tornisielo, V.L.

    1975-12-01

    Insects of the species Laemophloeus ferrugineus (Steph.) were irradiated with different gamma dose rates from a radial type Co-60 source. The rates utilized were 59580, 15750, 2750, 632, 154 and 63 rad/hour, respectively at 10, 20, 50, 100, 200 and 300 cm from the source. The insects were irradiated with a dose of 15000 rad. Death rate was checked every 7 days; starting from these numbers, life expectancy was estimated for each week in relation to respective dose rate. The following results were obtained for insects life expectancy estimates upon beginning of the experiment: 85.63 days (control); 19.50 (10 cm); 19.40 (20 cm); 20.40 (50 cm); 22.23 (100 cm); 22.00 (200 cm) and 23.11 (300 cm). The number of days until the last individuals of each dose rate died was also registered: 248 days (control); 31 (10 cm); 31 (20 cm); 31 (50 cm); 185 (100 cm); 164 (200 cm) and 143 (300 cm)

  1. From concentration to dose: factors influencing airborne particulate matter deposition in humans and rats

    NARCIS (Netherlands)

    Winter-sorkina R de; Cassee FR; LBV; LBO

    2003-01-01

    Particulate matter (PM) consisting of solid particles and droplets is present in the ambient air. Particles with an aerodynamic diameter less than 10 micro m can be inhaled by humans. Knowledge of the tissue-specific internal dose of PM is a critical link between individual external exposure and

  2. Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT

    International Nuclear Information System (INIS)

    Barras, Heloise; Dunet, Vincent; Hachulla, Anne-Lise; Grimm, Jochen; Beigelman-Aubry, Catherine

    2016-01-01

    Model-based iterative reconstruction (MBIR) reduces image noise and improves image quality (IQ) but its influence on post-processing tools including maximal intensity projection (MIP) and minimal intensity projection (mIP) remains unknown. To evaluate the influence on IQ of MBIR on native, mIP, MIP axial and coronal reformats of reduced dose computed tomography (RD-CT) chest acquisition. Raw data of 50 patients, who underwent a standard dose CT (SD-CT) and a follow-up RD-CT with a CT dose index (CTDI) of 2–3 mGy, were reconstructed by MBIR and FBP. Native slices, 4-mm-thick MIP, and 3-mm-thick mIP axial and coronal reformats were generated. The relative IQ, subjective IQ, image noise, and number of artifacts were determined in order to compare different reconstructions of RD-CT with reference SD-CT. The lowest noise was observed with MBIR. RD-CT reconstructed by MBIR exhibited the best relative and subjective IQ on coronal view regardless of the post-processing tool. MBIR generated the lowest rate of artefacts on coronal mIP/MIP reformats and the highest one on axial reformats, mainly represented by distortions and stairsteps artifacts. The MBIR algorithm reduces image noise but generates more artifacts than FBP on axial mIP and MIP reformats of RD-CT. Conversely, it significantly improves IQ on coronal views, without increasing artifacts, regardless of the post-processing technique

  3. The influence of different doses of caffeine on visual task performance

    NARCIS (Netherlands)

    Lorist, MM; Snel, J; Ruijter, J

    1999-01-01

    Tn this study the influence of caffeine as an energy-increasing substance on visual information processing was examined. Subjects were presented with a dual-task consisting of two choice reaction time tasks. In addition, one of the tasks was presented at two levels of difficulty, influencing the

  4. Epidemiological analysis of common influence of low doses of ionizing radiation, heavy metals and pesticides

    International Nuclear Information System (INIS)

    Shestopalov, V.M.; Naboka, M.V.

    1997-01-01

    Comparison of ecological danger of substances of a chemical and radiating nature on the territory of Chernobyl's exhaust of Kyiv area is conducted. Epidemiological analysis, is conducted in accordance with ''Methodological recommendations for radioecological assessment of territories by mapping''. Influence on children's morbity of 27 factors contamination of an environment (radiocesium, heavy metals, pesticides and fertilizer) was investigated. Analysis has shown, that the influence from all investigated ecological factors reaches 30-40%, differing in different zones of supervision. The influence of radioactive factors in the Northern part of Kyiv test site, is 6 times greater than the risk caused by heavy metals and agrochemical pollution. A greater influence of heavy metals was found in the center of the Kyiv test site. The result of our research on the territory of Chernobyl's exhaust shows that there exist factors of different nature which influence on human health is significant and create combinations dangerous for health. (author)

  5. Correction of CT artifacts and its influence on Monte Carlo dose calculations

    International Nuclear Information System (INIS)

    Bazalova, Magdalena; Beaulieu, Luc; Palefsky, Steven; Verhaegen, Frank

    2007-01-01

    Computed tomography (CT) images of patients having metallic implants or dental fillings exhibit severe streaking artifacts. These artifacts may disallow tumor and organ delineation and compromise dose calculation outcomes in radiotherapy. We used a sinogram interpolation metal streaking artifact correction algorithm on several phantoms of exact-known compositions and on a prostate patient with two hip prostheses. We compared original CT images and artifact-corrected images of both. To evaluate the effect of the artifact correction on dose calculations, we performed Monte Carlo dose calculation in the EGSnrc/DOSXYZnrc code. For the phantoms, we performed calculations in the exact geometry, in the original CT geometry and in the artifact-corrected geometry for photon and electron beams. The maximum errors in 6 MV photon beam dose calculation were found to exceed 25% in original CT images when the standard DOSXYZnrc/CTCREATE calibration is used but less than 2% in artifact-corrected images when an extended calibration is used. The extended calibration includes an extra calibration point for a metal. The patient dose volume histograms of a hypothetical target irradiated by five 18 MV photon beams in a hypothetical treatment differ significantly in the original CT geometry and in the artifact-corrected geometry. This was found to be mostly due to miss-assignment of tissue voxels to air due to metal artifacts. We also developed a simple Monte Carlo model for a CT scanner and we simulated the contribution of scatter and beam hardening to metal streaking artifacts. We found that whereas beam hardening has a minor effect on metal artifacts, scatter is an important cause of these artifacts

  6. Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells.

    Science.gov (United States)

    Laschinsky, Lydia; Karsch, Leonhard; Leßmann, Elisabeth; Oppelt, Melanie; Pawelke, Jörg; Richter, Christian; Schürer, Michael; Beyreuther, Elke

    2016-08-01

    Regarding the long-term goal to develop and establish laser-based particle accelerators for a future radiotherapeutic treatment of cancer, the radiobiological consequences of the characteristic short intense particle pulses with ultra-high peak dose rate, but low repetition rate of laser-driven beams have to be investigated. This work presents in vitro experiments performed at the radiation source ELBE (Electron Linac for beams with high Brilliance and low Emittance). This accelerator delivered 20-MeV electron pulses with ultra-high pulse dose rate of 10(10) Gy/min either at the low pulse frequency analogue to previous cell experiments with laser-driven electrons or at high frequency for minimizing the prolonged dose delivery and to perform comparison irradiation with a quasi-continuous electron beam analogue to a clinically used linear accelerator. The influence of the different electron beam pulse structures on the radiobiological response of the normal tissue cell line 184A1 and two primary fibroblasts was investigated regarding clonogenic survival and the number of DNA double-strand breaks that remain 24 h after irradiation. Thereby, no considerable differences in radiation response were revealed both for biological endpoints and for all probed cell cultures. These results provide evidence that the radiobiological effectiveness of the pulsed electron beams is not affected by the ultra-high pulse dose rates alone.

  7. Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells

    International Nuclear Information System (INIS)

    Laschinsky, Lydia; Karsch, Leonhard; Schuerer, Michael; Lessmann, Elisabeth; Beyreuther, Elke; Oppelt, Melanie; Pawelke, Joerg; Richter, Christian

    2016-01-01

    Regarding the long-term goal to develop and establish laser-based particle accelerators for a future radiotherapeutic treatment of cancer, the radiobiological consequences of the characteristic short intense particle pulses with ultra-high peak dose rate, but low repetition rate of laser-driven beams have to be investigated. This work presents in vitro experiments performed at the radiation source ELBE (Electron Linac for beams with high Brilliance and low Emittance). This accelerator delivered 20-MeV electron pulses with ultra-high pulse dose rate of 10"1"0 Gy/min either at the low pulse frequency analogue to previous cell experiments with laser-driven electrons or at high frequency for minimizing the prolonged dose delivery and to perform comparison irradiation with a quasi-continuous electron beam analogue to a clinically used linear accelerator. The influence of the different electron beam pulse structures on the radiobiological response of the normal tissue cell line 184A1 and two primary fibroblasts was investigated regarding clonogenic survival and the number of DNA double-strand breaks that remain 24 h after irradiation. Thereby, no considerable differences in radiation response were revealed both for biological endpoints and for all probed cell cultures. These results provide evidence that the radiobiological effectiveness of the pulsed electron beams is not affected by the ultra-high pulse dose rates alone. (orig.)

  8. Accuracy in radiosurgery: The influence of collimator diameters and arc weights on the dose distribution for single target

    Energy Technology Data Exchange (ETDEWEB)

    Plazas, M S [National Univ. of Colombia (Colombia); Lefkopoulus, D; Schlienger, M [Service de Radiotherapie, Hopital Tenon, Paris (France). Unite de Radiophysique; Merienne, L [Hopital Sainte Anne, Paris (France). Service de Neurochirurgie

    1996-08-01

    The dosimetric characteristics of mini-beams and dose distributions in beams used for radio surgery defer substantially from beams used in common radiotherapy. The aim of radio surgery is to deliver a high dose to the lesion in one single fraction, while minimizing the dose delivered to the surrounding normal brain tissue. This type of irradiation is performed with a number of continuous arcs located in various corneal (patient sitting) or sagittal (patient in a supine position) inclined planes using a linear accelerator. A treatment planning system should take into account a large number of irradiation parameters such as the collimator diameter, number of arcs, their angular positions, length and weight of the arcs. We analysed the influence of collimator diameters in the range of 6 to 20 mm using 15 MV X-rays and stereo-tactic irradiation of ellipsoidal inclined arterio venous malformations (AVMs) with a single isocenter. Special arc weights were used to obtain an optimized dose distribution with 13 arcs distributed over an angular sector of 120 deg. x 13 deg. In the two studies made we used 3 dimensional dosimetric calculations. The results were used for the treatment of patients and enabled the choice of the optimal irradiation configuration for each patient. (author). 10 refs, 9 figs.

  9. Influence of high-dose gamma radiation and particle size on antioxidant properties of Maize ( Zea mays L.) flour

    International Nuclear Information System (INIS)

    Nawaz, Haq; Shad, Muhammad Aslam; Rehman, Tanzila; Ramzan, Ayesha

    2016-01-01

    Influence of high-dose gamma radiation and particle size on antioxidant properties of maize (Zea mays L.) flour was studied using response surface methodology. A central composite design based on three levels of each of particle size, in terms of mesh number (40, 60 and 80 meshes), and gamma radiation dose (25, 50 and 75 kGy) was constructed. A statistically significant dose-dependent decrease (p<0.05) in antioxidant properties of gamma irradiated flour was observed. However, an increase in the mesh number (decrease in particle size of flour) resulted in an increase in antioxidant properties. The optimum level of radiation dose to achieve maximum value of responses was found to be 50 kGy for Trolox equivalent total antioxidant activity (TETAOA), 25 kGy for iron chelating ability (ICA), 25 kGy for reducing power (RP) and 75 kGy for linoleic acid reduction capacity (LARC). However, the optimum level of mesh number to achieve desired levels of TETAOA, ICA, RP and LARC was found to be 80 meshes. (author)

  10. Influence of high-dose gamma radiation and particle size on antioxidant properties of Maize ( Zea mays L.) flour

    Energy Technology Data Exchange (ETDEWEB)

    Nawaz, Haq; Shad, Muhammad Aslam; Rehman, Tanzila; Ramzan, Ayesha, E-mail: haqnawaz@bzu.edu.pk [Bahauddin Zakariya University, Multan (Pakistan)

    2016-10-15

    Influence of high-dose gamma radiation and particle size on antioxidant properties of maize (Zea mays L.) flour was studied using response surface methodology. A central composite design based on three levels of each of particle size, in terms of mesh number (40, 60 and 80 meshes), and gamma radiation dose (25, 50 and 75 kGy) was constructed. A statistically significant dose-dependent decrease (p<0.05) in antioxidant properties of gamma irradiated flour was observed. However, an increase in the mesh number (decrease in particle size of flour) resulted in an increase in antioxidant properties. The optimum level of radiation dose to achieve maximum value of responses was found to be 50 kGy for Trolox equivalent total antioxidant activity (TETAOA), 25 kGy for iron chelating ability (ICA), 25 kGy for reducing power (RP) and 75 kGy for linoleic acid reduction capacity (LARC). However, the optimum level of mesh number to achieve desired levels of TETAOA, ICA, RP and LARC was found to be 80 meshes. (author)

  11. Computed tomography: influence of varying tube current on patient dose and correctness of effective dose calculations; Computertomografie: Einfluss des variablen Roehrenstroms auf die Patientendosis und die Genauigkeit von Berechnungen der effektiven Dosis

    Energy Technology Data Exchange (ETDEWEB)

    Hietschold, V. [Inst. und Poliklinik fuer Radiologische Diagnostik, Universitaetsklinikum Carl-Gustav-Carus der TU Dresden (Germany); Koch, A.; Laniado, M.; Abolmaali, N.D. [OncoRay, Molecular Imaging, TU Dresden (Germany)

    2008-05-15

    Purpose: determination of the influence of tube currents varying during a CT scan on organ doses and on the effective dose as a function of patient constitution. Evaluation of the accuracy of effective dose calculations based on summarizing parameters (effective mAs, dose length product [DLP]) compared to calculations based on slice-specific tube currents. Materials and methods: investigation of the CT datasets of 806 patients acquired from the skull base to the proximal thigh with respect to the body mass index (BMI). The effective dose was calculated by means of slice-specific as well as region-specific conversion factors. Results: dose optimization by means of variable tube current resulted in a reduction of the gonad dose in patients with BMI {<=} 20.. 21 kg/m{sup 2} and of the effective dose in patients with BMI {<=} 26 kg/m{sup 2}. Effective dose values calculated with the DLP for 90% of the patients are within an interval of {+-} 20% of the values calculated using slice-specific tube currents. Conclusion: if tube current optimization during the CT scan was applied, for the scan region under investigation, at a BMI already below the German mean value, an increased effective dose was observed. Calculations of the effective dose on the basis of summarizing values such as DLP or effective mAs are of sufficient accuracy. (orig.)

  12. Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose

    International Nuclear Information System (INIS)

    Serduc, Raphael; Fonta, Caroline; Renaud, Luc; Bouchet, Audrey; Braeuer-Krisch, Elke; Sarun, Sukhena; Bravin, Alberto; Le Duc, Geraldine; Laissue, Jean A; Spiga, Jenny; Boutonnat, Jean; Siegbahn, Erik Albert; Esteve, Francois

    2009-01-01

    To analyze the effects of the microbeam width (25, 50 and 75 μm) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 μm wide microbeams, all spaced 211 μm on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 μm wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of ∼50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 μm width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 μm or 25 μm widths when used with a 211 μm on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in all groups. The use

  13. Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose

    Energy Technology Data Exchange (ETDEWEB)

    Serduc, Raphael; Fonta, Caroline; Renaud, Luc [Universite de Toulouse, UPS, Centre de Recherche Cerveau et Cognition (France); Bouchet, Audrey; Braeuer-Krisch, Elke; Sarun, Sukhena; Bravin, Alberto; Le Duc, Geraldine [European Synchrotron Radiation Facility, F38043 Grenoble (France); Laissue, Jean A [Institute of Pathology, University of Bern (Switzerland); Spiga, Jenny [Department of Physics, University of Cagliari, s.p. Monserrato-Sestu, Monserrato (Canada) 09042 (Italy); Boutonnat, Jean [TIMC lab, UMR CNRS 5525, Univ Joseph Fourier, CHU, Grenoble (France); Siegbahn, Erik Albert [Department of Medical Physics, Karolinska Universitetssjukhuset, 17176 Stockholm (Sweden); Esteve, Francois [INSERM U836, Equipe 6, Institut des Neurosciences de Grenoble, 38043 Grenoble Cedex (France)], E-mail: raph.serduc@gmail.com

    2009-11-07

    To analyze the effects of the microbeam width (25, 50 and 75 {mu}m) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 {mu}m wide microbeams, all spaced 211 {mu}m on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 {mu}m wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of {approx}50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 {mu}m width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 {mu}m or 25 {mu}m widths when used with a 211 {mu}m on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in

  14. Influence of conditioned psychological stress on immunological recovery in mice exposed to low-dose x irradiation

    International Nuclear Information System (INIS)

    Sato, K.; Flood, J.F.; Makinodan, T.

    1984-01-01

    A study was initiated to determine the effects of psychological stress on the immune response in BALB/c mice recovering from exposure to a low dose of ionizing radiation. Mice were first subjected to conditioning training for 12 days, then exposed to 200 R, subjected to psychological stress for 14 days, and assessed for peak anti-sheep RBC response. The seven treatment groups included two unirradiated groups and five irradiated groups. Mice exposed to 200 R and then subjected to conditioned psychological stress responded less vigorously to antigenic stimulation than those of the other irradiated groups. The psychological stress imposed upon these mice did not influence the antibody-forming capacity of unirradiated mice. These results indicate that a psychological stress which did not affect the immunological activity of unirradiated mice can curtail the immunological recovery of mice exposed to low doses of ionizing radiation

  15. A polymorphism in NFKB1 is associated with improved effect of interferon-alpha maintenance treatment of patients with multiple myeloma after high-dose treatment with stem cell support

    DEFF Research Database (Denmark)

    Vangsted, Annette J; Klausen, Tobias W; Gimsing, Peter

    2009-01-01

    and Methods: In a retrospective study of 296 patients with multiple myelom undergoing high-dose therapy between 1994 and 2004, 146 patients were treated with interferon- as maintenance therapy. We tested the polymorphisms IL1B T-31C, IL6 G-174C, NFKB1-94ins/delATTG, CD3EAP G-21A and PPP1R13L IVS1 A4364G...... homozygous for the wild type G allele of IL6 G-174C who survived longer (p= 0.0074) than variant allele carriers. There was no association between the polymorphisms IL1B T-31C, CD3EAP G-21A and PPP1R13L IVS1 A4364G and treatment outcome for interferon-. Conclusions: Patients who are homozygous carriers...

  16. Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality.

    Science.gov (United States)

    Nauer, Claude Bertrand; Zubler, Christoph; Weisstanner, Christian; Stieger, Christof; Senn, Pascal; Arnold, Andreas

    2012-03-01

    The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80 kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3 mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = -0.94/-0.88) and was highest at 80 kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80 kV. However, image quality improvement was most relevant for low-dose scans. Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80 kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocols.

  17. Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality

    International Nuclear Information System (INIS)

    Nauer, Claude Bertrand; Zubler, Christoph; Weisstanner, Christian; Stieger, Christof; Senn, Pascal; Arnold, Andreas

    2012-01-01

    The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80 kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3 mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = -0.94/-0.88) and was highest at 80 kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80 kV. However, image quality improvement was most relevant for low-dose scans. Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80 kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocols. (orig.)

  18. Age influence on retention, distribution and internal doses of 85Sr in rat

    International Nuclear Information System (INIS)

    Tian Wuxun; Wang Decheng; Zhang Hongyuan

    1990-01-01

    After I.V. 85 Sr, the whole body 85 Sr-retentions in rats were fit to two compartment exponential equations. The equation parameters showed a significantly difference between the young group and both the adult and old groups (p 2 ) for 85 Sr in the slow compartment decreased in regular order from the young to the old groups. In the bone 85 Sr-retention equations Tb 2 of the slow compartment for 85 Sr in the young group was significantly lower than the adult and old groups. The doses of the whole body and red-marrow for young rats were 4.2 times as much as those of adult rats, and 6.2 and 5.9 times as much as those old rats. The dose-cumulative speeds was most quick in the young groups and similar in the adult and the old

  19. The influence of parameters of A-type carbonated apatites synthesis on radiation dose response

    International Nuclear Information System (INIS)

    Oliveira, Liana Macedo de; Lopes, Ricardo Tadeu

    2000-01-01

    The aim of this work is the investigation of dose response of A-type carbonated apatites prepared in different conditions. Irradiated samples prepared with carbonate content of 1.45 to 4.84% are studied by using electron paramagnetic resonance (EPR). The EPR spectra are mainly constituted of lines associated to axial CO 2 - species (g perp = 2.0028 and g // = 1.9973) and CO 3 - species (g 1 = 2,0170, g 2 = 2,0090 e g 3 = 2,0041). The production of CO 2 - species on gamma irradiation depends on the carbonate concentration and the hydroxyapatite stoichiometry. The lowest dose detection limit was achieved with stoichiometric samples and carbonate content around of 3.7%. (author)

  20. The influence of low doses of ionizing radiation on biological systems

    International Nuclear Information System (INIS)

    Kwiecinska, T.

    1986-11-01

    Recent results concerning possible beneficial effects of low doses of ionizing radiation on biological systems are summarized. It is also pointed out on the basis of existing evidence that harmful effects on living organisms take place not only in the case of excess but also in the case of deficiency of ionizing radiation. Possibility of using radio-enhanced ultralow luminescence for studying hormesis phenomena is discussed. 24 refs., 4 figs. (author)

  1. Influence of different exposure modes on image quality and radiation dose in digital mammography

    International Nuclear Information System (INIS)

    Liu Jie; Wang Xia; Li Xiaokang; Liu Peifang

    2013-01-01

    Objective: To evaluate the effect of different exposure modes on radiation dose and image quality in digital mammography, and to explore how to reduce patient's radiation injury by choosing proper exposure mode and exposure conditions without sacrifice image quality. Methods: A breast phantom was exposed by using automatic exposure mode (60 mAs, 28 k/V) and manual exposure modes (37.5 to 70 mAs range, 24 to 32 kV range) respectively. Same oppression thickness and pressure were set for all modes. The average glandular dose (AGD), entrance surface dose (ESD), and image quality score according to American College of Radiology (ACR) criteria were recorded for each image. Kruskal Wallis test was used to compare the image quality scores between automatic and manual modes. All statistic analyses were performed by using SPSS17.0. Results: Compared to automatic exposure mode (60 mAs, 28 k/V), the overall score of image quality of manual modes (45 to 70 mAs range, 26 to 32 kV range) had no significant difference. Both ESD and ACD decreased 26.1% and increased 15.4% when the tube loading was changed from 60 mAs to 45 mAs and 70 mAs respectively. The ESD and ACD decreased 22.6%, 28.2% and increased 47.0%, 62.7% when the tube voltage was changed from 28 kV to 26 kV and 32 kV respectively. Conclusion: When the image quality reaches to a certain level, it will not be raised by a higher photographic condition. Without sacrifice image quality, the tube loading and tube voltage can be manually decreased to reduce radiation dose. (authors)

  2. Influence of lead apron shielding on absorbed doses from cone-beam computed tomography.

    Science.gov (United States)

    Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ichiro; Sawada, Kunihiko; Schulze, Dirk

    2017-06-01

    The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO® phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500®, ProMax® 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax® 3D with shielding, the ED was 149 µSv, and for the examination protocol without shielding 148 µSv (SD = 0.31 µSv). For the CS 9500®, the ED was 88 and 86 µSv (SD = 0.95 µSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Influence of lead apron shielding on absorbed doses from cone-beam computed tomography

    International Nuclear Information System (INIS)

    Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ichiro; Sawada, Kunihiko; Schulze, Dirk

    2017-01-01

    The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO"R phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500"R, ProMax"R 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax"R 3D with shielding, the ED was 149 μSv, and for the examination protocol without shielding 148 μSv (SD = 0.31 μSv). For the CS 9500"R, the ED was 88 and 86 μSv (SD = 0.95 μSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam. (authors)

  4. The influence of dose distributions on the results of UV-biodosimetry

    International Nuclear Information System (INIS)

    Cabaj, A.; Sommer, R.; Kundi, M.

    1996-01-01

    Disinfection of drinking water with ultraviolet radiation has become a common method in Austria and in many other countries. The water usually is disinfected in flow through systems with low pressure mercury lamps as UV source, which emit predominantly UV radiation with wavelength 253.7 nm. Because of varying residence times of microorganizms and the special distribution of fluence rate in the irradiation volume, caused by different distances from the radiation source, by absorption of radiation in the water and by reflexion at the walls of the reactor, the microorganizms passing through in a turbulent flow, receive different fluences. In Austria UV-disinfection plants for drinking water must deliver a minimal dose of 400 Jm -2 for radiation of wavelength 253.7 nm. The fulfillment of this demand is proved during type testing. As dosimeter suspensions of bacterial spores are used whose UV-susceptibility has to be measured in a laboratory irradiation device. The dose, determined in this way, is called Reduction Equivalent Dose'. (author)

  5. The potential influence of cell protectors for dose escalation in cancer therapy: an analysis of amifostine

    International Nuclear Information System (INIS)

    McCumber, Linda M.

    2004-01-01

    The attempt to increase the therapeutic ratio in an effort to improve survival or quality of life is the goal of modern cancer therapy. It is commonly accepted that local and systemic tumor control would increase if the dose intensity of antineoplastic drugs, radiation therapy, or the combination were increased. Radiation dose escalation using intensity-modulated radiation therapy (IMRT), accelerated or hypofractionated radiation schemes, and multidrug chemotherapy regimens are being used to try to increase tumor kill while inflicting minimal injury to normal tissue. Modern chemoradiation techniques have led to improved local regional control and increased cure rates, but the potentially severe and debilitating adverse effects of the therapies prevent them from reaching the ultimate goal of curing the disease while leaving the patient with a good quality of life. Cell protectants such as amifostine function by reducing the effects of therapy on normal cells while maintaining tumor sensitivity to the therapy. In various studies, amifostine has been analyzed and appears to be a potentially powerful adjuvant to current cancer therapy. Administering amifostine may allow dose escalation with less or equal risk to surrounding normal tissues. This could improve therapeutic efficacy, survival, and quality of life for cancer patients

  6. VKORC1-1639G>A, CYP2C9, EPHX1691A>G genotype, body weight, and age are important predictors for warfarin maintenance doses in patients with mechanical heart valve prostheses in southwest China.

    Science.gov (United States)

    Gu, Qiang; Kong, Yan; Schneede, Jörn; Xiao, Ying-Bin; Chen, Lin; Zhong, Qian-Jin; Wang, Xue-Feng; Hao, Jia; Chen, Bai-Cheng; Chen, Jing-Jin

    2010-12-01

    To investigate the contribution of genetic polymorphisms of vitamin K epoxide reductase complex subunit 1 gene VKORC1-1639G>A, cytochrome P450 2C9 gene (CYP2C9), EPHXI, and clinical factors to warfarin sensitivity in southwest Chinese Han patients with mechanical heart valve prostheses. A total of 127 patients with mechanical heart valve prostheses who have been followed up at our department during the past 23 years were enrolled in this study and compared to a control group that consisted of 133 randomly selected healthy blood donors. These Chinese patients met stable warfarin dosage requirements and had reached the target international normalized ratio (INR) of 1.5-2.0. PCR and direct sequencing were carried out to identify the polymorphisms of VKORC1-1639G>A (rs9923231), CYP2C9*3 (rs1057910), CYP2C9 IVS3-65G>C (rs9332127), and EPHX1691A>G (rs4653436). In addition, total and free (non-protein-bound) warfarin concentrations were analyzed. There were great interindividual differences in warfarin maintenance dosage (ranging from 0.6 to 8.4 mg/day) among the 127 patients with mechanical heart valve prostheses. VKORC1-1639G>A, CYP2C9, EPHX1691A>G polymorphism, body weight, and age were found to affect the dose demands. Multiple linear regression models incorporating genetic polymorphisms of VKORC1, CYP2C9, EPHX1691A>G, and the nongenetic factors of age and body weight were developed, and explained up to 76.8% of the total variation (adjusted R (2) of 0.743) in warfarin maintenance doses in southwest Chinese patients with mechanical heart valve prostheses.

  7. Tolerance of Glyphosate-Resistant Maize to Glyphosate Plus MCPA Amine Is Influenced by Dose and Timing

    Directory of Open Access Journals (Sweden)

    Nader Soltani

    2015-01-01

    Full Text Available There is little information on tolerance of glyphosate-resistant maize to glyphosate plus MCPA amine as influenced by dose and timing under Ontario environmental conditions. A total of seven field trials were conducted at various locations in Ontario, Canada, in 2011–2013 to evaluate tolerance of field maize to tank mixes of glyphosate (900 g a.e./ha plus MCPA amine (79, 158, 315, 630, 1260, 2520, or 5040 g a.e./ha at either the 4- or 8-leaf stage. The predicted dose of MCPA amine that caused 5, 10, and 20% injury was 339, 751, and 1914 g a.e./ha when applied to 4-leaf maize but only 64, 140, and 344 g a.e./ha when applied to 8-leaf maize, respectively. The predicted dose of MCPA amine that caused 5, 10, and 20% reduction in shoot dry weight of maize was 488, 844, and 1971 g a.e./ha when applied to 4-leaf maize and only 14, 136, and 616 g a.e./ha when applied to 8-leaf maize, respectively. The predicted dose of MCPA amine that caused 5, 10, and 20% yield reduction was 2557, 4247, and >5040 g a.e./ha when applied to 4-leaf maize and 184, 441, and 1245 g a.e./ha when applied to 8-leaf maize, respectively. Based on these results, glyphosate plus MCPA amine applied at the manufacturer’s recommended dose of 630 g a.e./ha applied to 4-leaf maize has potential to cause injury but the injury is transient with no significant reduction in yield. However, when glyphosate plus MCPA amine is applied to 8-leaf maize it has the potential to cause significant injury and yield loss in maize.

  8. Influence of the number of daily pills and doses on adherence to antiretroviral treatment: a 7-year study.

    Science.gov (United States)

    Hernández Arroyo, M J; Cabrera Figueroa, S E; Sepúlveda Correa, R; Valverde Merino, M P; Luna Rodrigo, G; Domínguez-Gil Hurlé, A

    2016-02-01

    Antiretroviral treatment (ART) is hampered by complicated regimens, high pill burden, drug-drug interactions, and frequent short- and long-term adverse effects, leading to decreased adherence. Over recent years, considerable effort has been directed at developing regimens that are less burdening. We undertook a 7-year retrospective study of the records of 264 HIV-infected subjects enrolled in a pharmaceutical care programme to document the progress made and to study the influence of the number of ART pills and doses on the level of treatment adherence. Antiretroviral dispensing records were analysed for the number of pills and doses administered and the ART adherence rate estimated. In 2005, the patients took a mean of 6·2 pills daily (CI 95%: 5·9-6·6), and 92·9% of them were on a twice-a-day (BID) dosage regimen. By 2012, the mean number of pills was reduced to 4·1 (CI 95%: 3·8-4·4), and only 50·9% were on a BID regimen. No statistically significant relation was observed between number of daily pills and doses and ART adherence reached by the patients in any of the analyses performed. There has been a continuous reduction in the number of pills and doses of antiretrovirals taken by individual patients over the last 7 years due largely to the introduction of improved treatments and regimens. More daily pills or doses was not associated with worse ART adherence in our pharmaceutical care programme. © 2015 John Wiley & Sons Ltd.

  9. Influence of low doses chronic contamination on the progression of atheromatous pathology

    International Nuclear Information System (INIS)

    Le-Gallic, Clelia

    2015-01-01

    Large amounts of radionuclides were released in the environment after the Chernobyl (1986) or Fukushima-Daichii (2011) nuclear accidents, and mostly cesium 137. Populations living in contaminated territories are chronically exposed to radionuclides by ingestion of contaminated food. There is a real interrogation about the potential effects that could be induced following such ionizing exposure on physiological functions in the long term. Concerning the cardiovascular system, there is a correlation between the irradiation dose and the appearance of cardiovascular diseases. However, when we focused on post-accidental situations, with a low dose exposure, available data are not all in accordance, due to multifactorial aspect of these pathologies. Epidemiological results should be interpreted carefully. Thus, the aim of my thesis is to complete epidemiological studies about chronic internal? low dose exposure, using cesium 137, in an atheromatous context. Atherosclerosis and its consequences are known to be the main cause of mortality/morbidity in industrialized countries. Predisposed animals (ApoE-/- mice) were exposed to 137 Cs through the drinking water. The concentration range was 4 to 100 kBq.L -1 , to surround concentration found in contaminated territories around Chernobyl. Exposure times were 3, 6 or 9 months to follow atherosclerosis progression. After 3 months exposure, for the early stages, mice exposed to the highest dose presented an increase in some inflammatory cytokines, notably IFN-γ and VCAM-1, with an intimal-medial thickness increased compared to non-exposed animals. Moreover, at this time exposure, we noticed concomitant variation of gene expression of pro and anti-oxidative enzymes (p47, p67, GPx). These effects are only transient and do not persist over the time. Indeed, after 6 and 9 months exposure, atheromatous plaque observed in the aortic sinus, present more stability parameters than the control group (collagen), with also a decrease in pro

  10. Twelve-hour brain lithium concentration in lithium maintenance treatment of manic-depressive disorder: daily versus alternate-day dosing schedule

    DEFF Research Database (Denmark)

    Jensen, H.V.; Plenge, P; Stensgaard, A

    1996-01-01

    The 12-h brain lithium concentration was measured by lithium-7 magnetic resonance spectroscopy in ten manic-depressive patients receiving daily or alternate-day lithium carbonate treatment. The median dose of lithium carbonate was 800 mg in the daily treatment group and 1200 mg in the alternate......-day group. Median 12-h serum lithium concentration in the two groups was 0.86 mmol l-1 and 0.55 mmol l-1, respectively, while the corresponding concentration in brain was 0.67 mmol l-1 and 0.52 mmol l-1, respectively. The 12-h brain lithium concentration was independent of lithium dosing schedule (multiple...... linear regression), but correlated significantly with the 12-h serum lithium concentration (P = 0.003; B = 0.53, 95% c.l. 0.24-0.82; beta = 0.83). Thus at identical 12-h serum lithium concentrations the 12-h brain lithium concentration is similar with both treatment regimes. As the risk of manic...

  11. Tacrolimus concentration/dose ratio as a therapeutic drug monitoring strategy: The influence of gender and comedication

    Directory of Open Access Journals (Sweden)

    Rančić Nemanja

    2015-01-01

    Full Text Available Background/Aim. A combination of tacrolimus and other drugs such as corticosteroids has been commonly used immunosuppresive regimens. On the other hand, there is a growing body of evidence that male and female may differ in their response to the equal drug treatment. The aim of the study was to estimated the use of tacrolimus concentration/dose (C/D ratio for the assessment of the influence of gender differences and comedication on tacrolimus exposure in renal transplant recipients. Methods. This prospective case series study included 54 patients, in which the unit of monitoring was outpatient examination (1,872 of the renal transplant patients. The patients were monitored in the period 2010-2014, starting one month after the transplantation. Tacrolimus trough concentrations (TTC were measured by chemiluminescence microparticles immunoassay. Results. TTC and the tacrolimus C/D ratio were significantly lower in the females comparing with the males. Contrary to the males, in the females a significant increase of the tacrolimus daily dose (TDD per body weight and TTC, along with the corticosteroid dose increase, was not accompanied by any significant changes in the tacrolimus C/D ratio; in different corticosteroid doses faster elimination of tacrolimus was found with the exception of the doses > 0.25 mg/kg. In the patients treated with proton pump inhibitors, mainly with pantoprazole TDD per body weight and TTC were significantly higher, while the tacrolimus C/D ratio was significantly lower compared to the patients without this treatment. In the patients treated with calcium channel blockers, TDD per body weight was significantly lower (particularly with amlodipine while the tacrolimus C/D ratio was higher compared to the patients who were not treated by them. Conclusion. A lower tacrolimus exposure was detected in females in comparison to males. When gender differences were considered in the context of different corticosteroid doses, faster

  12. Plane of nutrition during the preweaned period and Mannheimia haemolytica dose influence metabolic responses in post-weaned Holstein calves challenged with bovine herpesvirus-1 and Mannheimia haemolytica

    Science.gov (United States)

    To determine whether previous plane of milk replacer nutrition (PON) and M. haemolytica (MH) dose influences metabolic responses to a combined viral-bacterial respiratory challenge, Holstein calves (1 day of age; n=30) were assigned to treatments in a 2 x 3 factorial with preweaned PON and dose of M...

  13. Alcohol dose dumping: The influence of ethanol on hot-melt extruded pellets comprising solid lipids.

    Science.gov (United States)

    Jedinger, N; Schrank, S; Mohr, S; Feichtinger, A; Khinast, J; Roblegg, E

    2015-05-01

    The objective of the present study was to investigate interactions between alcohol and hot-melt extruded pellets and the resulting drug release behavior. The pellets were composed of vegetable calcium stearate as matrix carrier and paracetamol or codeine phosphate as model drugs. Two solid lipids (Compritol® and Precirol®) were incorporated into the matrix to form robust/compact pellets. The drug release characteristics were a strong function of the API solubility, the addition of solid lipids, the dissolution media composition (i.e., alcohol concentration) and correspondingly, the pellet wettability. Pellets comprising paracetamol, which is highly soluble in ethanol, showed alcohol dose dumping regardless of the matrix composition. The wettability increased with increasing ethanol concentrations due to higher paracetamol solubilities yielding increased dissolution rates. For pellets containing codeine phosphate, which has a lower solubility in ethanol than in acidic media, the wettability was a function of the matrix composition. Dose dumping occurred for formulations comprising solid lipids as they showed increased wettabilities with increasing ethanol concentrations. In contrast, pellets comprising calcium stearate as single matrix component showed robustness in alcoholic media due to wettabilities that were not affected by the addition of ethanol. The results clearly indicate that the physico-chemical properties of the drug and the matrix systems are crucial for the design of ethanol-resistant dosage forms. Moreover, hydrophobic calcium stearate can be considered a suitable matrix system that minimizes the risk of ethanol-induced dose dumping for certain API's. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    Energy Technology Data Exchange (ETDEWEB)

    Stoelting, T.; Knauerhase, H.; Klautke, G. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Kundt, G. [Inst. for Medical Informatics and Biometry, Univ. of Rostock (Germany); Fietkau, R. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Dept. of Radiotherapy, Univ. of Erlangen (Germany)

    2008-09-15

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p < 0.001 vs. interruption), patients < 60 years (OR 23.0; p < 0.001 vs. {>=} 70 years), and a single dose of 2 Gy (OR 11.0; p = 0.027 vs. 4-15.0 Gy). Significant parameters for recalcification in the multivariate analysis were concurrent chemotherapy (OR 12.3; p < 0.001 vs. no chemotherapy), no fractures in the TV (OR 5.9; p < 0.004 vs. fracture), and a dose of 40-< 50 Gy (OR 21.9; p = 0.035 vs. < 30 Gy) or {>=} 50 Gy (OR 26.4; p = 0.033 vs. < 30 Gy). Conclusion: radiotherapy is a very effective palliative treatment. Patients with a reduced general condition, with multiple bone lesions and a poor prognosis profit from short-term schemes (e.g., 1 x 8 Gy to 10 x 3 Gy). Patients in good general condition with a life expectancy of > 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  15. Influence of different anode/filter combination on radiation dose and image quality in digital mammography

    International Nuclear Information System (INIS)

    Liu Jie; Liu Peifang; Zhang Lianlian; Ma Wenjuan

    2013-01-01

    Objective: To explore the effect of different anode/filter combination on radiation dose and image quality in digital mammography, so as to choose optimal anode/filter combination to reduce radiation injury without scarifying image quality. Methods: Mammography accredition phantoms with the thickness from 1.6 cm to 8.6 cm were used to simulate human breast tissue. The same exposure conditions, pressure, compression thickness. and different anode/filter combination were employed under the automatic and manual exposure modes. The image kV, mAs, pressure, filter, average glandular dose (ACD), contrast to noise ratio (CNR) were recorded and the figure of merit (FOM) was calculated. SPSS 17.0 and one-way analysis of variance were used in the statistical analysis. Results: As the phantom thickness increase, the ACD values which were acquired with Mo/Mo, Mo/Rh, and W/Ag three different anode/filter combinations were increased, but CNR and FOM values were decreased, ACD, CNR, and FOM values which were acquired in the phantom with different thickness, and three different anode/filter combinations were statistically different (P=0.000, respectively). The ACD values of Mo/Mo were lowest. For 1.6 cm-2.6 cm phantom thicknesses, the FOMs of Mo/Rh were lowest, and for 3.6 cm-8.6 cm phantom thicknesses, the FOMs of W/Ag were lowest. Conclusion: Phantom thickness in 1.6 cm-2.6 cm and 3.6 cm-8.6 cm. Mo/Rh combination and W/Ag combination respectively can achieve the highest FOM, and can provide the best imaging quality with low radiation dose. (authors)

  16. Influence of irradiation dose on laser-induced surface nanostructures on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Varlamova, Olga [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Cottbus JointLab, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Bounhalli, Mourad [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Laboratoire Hubert Curien, Université St. Etienne, Bâtiment F 18 Rue du Professeur Benoît Lauras, 42000 Saint-Etienne (France); Reif, Juergen, E-mail: REIF@TU-COTTBUS.DE [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Cottbus JointLab, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany)

    2013-08-01

    We report on the dependence of femtosecond laser-induced periodic surface structures on an increase of incident pulse number. On silicon, the patterns evolve from linear, parallel sub-wavelength ripples, grossly perpendicular to the laser polarization, via coalesced wider features parallel to the polarization, to a crater with periodically structured, pillar-like walls. Closer inspection of the patterns indicates that the different features always continue to exhibit reminiscence to the preceding lower-dose patterns, suggesting that, indeed, all patterns can be created by ONE single GENERAL formation process, as in self-organized structure formation, and the different structures/feature sizes are NOT due to DIFFERENT mechanisms.

  17. Influence of irradiation dose on laser-induced surface nanostructures on silicon

    International Nuclear Information System (INIS)

    Varlamova, Olga; Bounhalli, Mourad; Reif, Juergen

    2013-01-01

    We report on the dependence of femtosecond laser-induced periodic surface structures on an increase of incident pulse number. On silicon, the patterns evolve from linear, parallel sub-wavelength ripples, grossly perpendicular to the laser polarization, via coalesced wider features parallel to the polarization, to a crater with periodically structured, pillar-like walls. Closer inspection of the patterns indicates that the different features always continue to exhibit reminiscence to the preceding lower-dose patterns, suggesting that, indeed, all patterns can be created by ONE single GENERAL formation process, as in self-organized structure formation, and the different structures/feature sizes are NOT due to DIFFERENT mechanisms.

  18. Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

    International Nuclear Information System (INIS)

    Gomez-Cardona, Daniel; Nagle, Scott K.; Li, Ke; Chen, Guang-Hong; Robinson, Terry E.

    2015-01-01

    levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation

  19. Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Cardona, Daniel [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Nagle, Scott K. [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Department of Pediatrics, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Li, Ke; Chen, Guang-Hong, E-mail: gchen7@wisc.edu [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Robinson, Terry E. [Department of Pediatrics, Stanford School of Medicine, 770 Welch Road, Palo Alto, California 94304 (United States)

    2015-10-15

    levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.

  20. Relationship between Corrected-QT Intervals and Other ECG Characteristics with Methadone Dose in Methadone Maintenance Treatment (MMT Patients and Healthy Subjects: A Case- Control Study

    Directory of Open Access Journals (Sweden)

    Mina Akbari Rad

    2017-05-01

    Full Text Available Background In this study we assessed the relationship between corrected-QT intervals and other ECG characteristics with methadone dose and other parameters in MMT patients and healthy subjects. Methods This was a case-control study which was carried out on patients underwent MMT and healthy control group who had been referred to Ebne-Sina academic hospital, Mashhad during 2014 - 2015. At the time of the study, 40 patients who received MMT therapy for at least 6 months and 40 voluntary healthy subjects who matched on age and sex enrolled in the study. 12-lead ECG was performed for all the patients. Mean QT interval, PR interval and QRS duration in every 12 leads were documented for each patient in maximum. Results To evaluate the patients, we divided 80 patients into two groups: 40 patients under treatment with Methadone and 40 voluntary participants as control group. There were 20 males and 20 females in each group. Duration of addiction was 214.80 ± 126.99 months in MMT group. Significant differences were observed in PRi between the patient and control groups (P = 0.007, and also between methadone dose and PRi (r = 0.468, P = 0.038 in males. QTc prolongation was reported in 4 patients of addicted group (10%. All of the QTc prolongation patients were female (P = 0.037. There was significant relationship between PRi and weight (P = 0.015, addiction period (P = 0.011, methadone treatment period (P = 0.018 as well as methadone dosage (P = 0.14. Methadone cut off point of 65 mg had a significant relationship with systolic blood pressure (P = 0.002, diastolic blood pressure (P = 0.013, QTCi (P = 0.016 and QRS (P = 0.044; however, no significant relationship was reported with PRi (P = 0.451. Conclusions We found that there is no exact dosage of methadone in which the side effects such as TdP (Torsade de pointes or QTc prolongation can be predicted. Female gender and methadone dosage ≥ 65 mg were risk factors of our study for QTc prolongation which

  1. The route of administration (oral vs intravenous) does not influence dose or outcome in Graves' disease and unifocal autonomy

    International Nuclear Information System (INIS)

    Schneider, Peter; Biko, Johannes; Haenscheid, Heribert; Hilliger, Stephan; Koutsampelas, Christos; Kranzfelder, Michael; Ladner, Stephan; Reiners, Christoph

    2005-01-01

    In a prospective randomised study, we investigated the influence of the route of administration of radioiodide on dosimetry and therapy outcome. Fifty-four patients suffering from Graves' disease (GD) and 60 patients with unifocal autonomy (UA) participated in the study and were randomly treated with either orally or intravenously administered radioiodide. Pretherapeutic dosimetry was based on single uptake measurements with a calibrated uptake probe system. The radioiodine kinetics during hospitalisation was assessed by daily bedside uptake measurements. Therapeutic dose was determined by half-life and thyroid uptake at the time of discharge using the same uptake probe as for the radioiodine test. No improvement in accuracy of dosimetry was achieved when radioiodide was administered intravenously. Mean therapeutic doses were identical following intravenous or oral administration. Variation in the achieved dose was slightly higher in the patients receiving oral administration, this being attributable to larger deviations in discrete activities of the capsules administered as compared with the values determined by dosimetry. No differences according to treatment modality were found with regard to therapeutic outcome. Eighty-seven patients attended 6-month follow-up after therapy. In the UA group, successful treatment, defined as a normal or elevated TSH level, was observed in 94% of patients after oral administration and in 80% after intravenous administration; corresponding figures in the GD group were 68% and 65%. The causes of individual differences between targeted and therapeutically achieved doses remain undetermined. Variations in the bioavailability of radioiodide or other parameters affecting thyroid status may be involved, and further investigations are needed to clarify this. (orig.)

  2. Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats.

    Science.gov (United States)

    Miller, Douglas L; Li, Peng; Dou, Chunyan; Gordon, David; Edwards, Chris A; Armstrong, William F

    2005-10-01

    To detect specific cardiomyocyte injury induced by myocardial contrast material-enhanced echocardiography (ie, myocardial contrast echocardiography) in rats and to ascertain the influences of contrast material dose and ultrasound exposure on this injury. All animal procedures were approved by the university committee for the use and care of animals. Myocardial contrast echocardiography with 1:4 electrocardiographic (ECG) triggering was performed at 1.5 MHz in 61 anesthetized rats. Evans blue (EB) dye was injected as the vital stain for cardiomyocyte injury. At the start of myocardial contrast echocardiography, which lasted 10 minutes, perflutren lipid microsphere-based contrast material was infused through the tail vein for 5 minutes. Premature heartbeats were counted from the ECG record. The numbers of EB-stained cells counted on sections of heart specimens obtained 24 hours after myocardial contrast echocardiography and then either fresh frozen or embedded in paraffin were determined by using fluorescence microscopy. Results were compared statistically by using t tests and Mann-Whitney rank sum tests. EB-stained cells were concentrated in the anterior region of the myocardium. In the paraffin-embedded specimens, EB-stained cells were often accompanied by but largely separate from areas of inflammatory cell infiltration. At end-systolic triggering with a 50 microL/kg dose of microsphere contrast material, the EB-stained cell count increased with increasing peak rarefactional pressure amplitude, with significantly increased cell counts at 1.6 MPa (P .1). EB-stained cell counts increased with increasing contrast material dose, from 10 to 50 microL/kg, at 2.0 MPa. Cardiomyocyte injury was induced by the interaction of ultrasound pulses with contrast agent microbubbles during myocardial contrast echocardiography in rats, and the numbers of injured cells increased with increasing contrast agent dose and ultrasound exposure. RSNA, 2005

  3. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    International Nuclear Information System (INIS)

    Stoelting, T.; Knauerhase, H.; Klautke, G.; Kundt, G.; Fietkau, R.

    2008-01-01

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  4. Epigenetic influences of low-dose bisphenol A in primary human breast epithelial cells

    International Nuclear Information System (INIS)

    Weng, Yu-I; Hsu, Pei-Yin; Liyanarachchi, Sandya; Liu, Joseph; Deatherage, Daniel E.; Huang Yiwen; Zuo Tao; Rodriguez, Benjamin; Lin, Ching-Hung; Cheng, Ann-Lii; Huang, Tim H.-M.

    2010-01-01

    Substantial evidence indicates that exposure to bisphenol A (BPA) during early development may increase breast cancer risk later in life. The changes may persist into puberty and adulthood, suggesting an epigenetic process being imposed in differentiated breast epithelial cells. The molecular mechanisms by which early memory of BPA exposure is imprinted in breast progenitor cells and then passed onto their epithelial progeny are not well understood. The aim of this study was to examine epigenetic changes in breast epithelial cells treated with low-dose BPA. We also investigated the effect of BPA on the ERα signaling pathway and global gene expression profiles. Compared to control cells, nuclear internalization of ERα was observed in epithelial cells preexposed to BPA. We identified 170 genes with similar expression changes in response to BPA. Functional analysis confirms that gene suppression was mediated in part through an ERα-dependent pathway. As a result of exposure to BPA or other estrogen-like chemicals, the expression of lysosomal-associated membrane protein 3 (LAMP3) became epigenetically silenced in breast epithelial cells. Furthermore, increased DNA methylation in the LAMP3 CpG island was this repressive mark preferentially occurred in ERα-positive breast tumors. These results suggest that the in vitro system developed in our laboratory is a valuable tool for exposure studies of BPA and other xenoestrogens in human cells. Individual and geographical differences may contribute to altered patterns of gene expression and DNA methylation in susceptible loci. Combination of our exposure model with epigenetic analysis and other biochemical assays can give insight into the heritable effect of low-dose BPA in human cells.

  5. Assessment of influence of OSL dosimeters in the skin dose in radiotherapy: study for Monte Carlo simulation; Avaliacao da influencia de dosimetros OSL na dose na pele em radioterapia: estudo por simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Schuch, Franciely F.; Nicolucci, Patricia, E-mail: franschuch@yahoo.com.br [Universidade de Sao Paulo (USP), Ribeiraoo Preto, SP (Brazil)

    2017-11-01

    The interest in optically stimulated luminescence (OSL) dosimetry materials is growing due to its potential use in quality control in Radiotherapy. The use of these dosimeters for in vivo dosimetry, however, may influence the dose to the skin and deeper tissues in the patient. The goal of this study is to evaluate the influence of the OSL Al{sub 2}O{sub 3} material in dose deposited in the skin and deep in Radiotherapy. Monte Carlo simulation is used to evaluate this purpose when OSL dosimeters of Al{sub 2}O{sub 3} are positioned on the skin surface of the patient. Percentage depth dose curves for clinical beams of 6 and 10 MV were simulated with and without the presence of the dosimeter on the surface of a water phantom. The results showed a decrease of doses in regions close to the surface of the skin. In the build-up region, the maximum decreases of dose produced by the presence of the dosimeters were 52,5% and 47,5% for the 6 and 10 MV beams, respectively. After the build-up region, there are not significant changes in the doses for any of the used beams. The differences of doses found are due to the influence of the dosimetric material on the relative fluence of electrons near the end surface of the dosimeter. Thus, the results showed that the presence of the dosimetric material on the surface interferes on the skin dose. However, these dosimeters do not cause dose variations in depths of clinical interest, allowing its application in routine in vivo dosimetry in Radiotherapy. (author)

  6. Maintenance planning for nuclear power plants

    International Nuclear Information System (INIS)

    Mattu, R.K.; Cooper, S.E.; Lauderdale, J.R.

    2004-01-01

    Maintenance planning for nuclear power plants is similar to that in other industrial plants but it is heavily influenced by regulatory rules, with consequent costs of compliance. Steps by the nuclear industry and the Nuclear Regulatory Commission to address that problem include development of guidelines for maintenance of risk-critical equipment, using PRA-based techniques to select a set of equipment that requires maintenance and reliability-centered maintenance (RCM) approaches for determining what maintenance is required. The result of the process is a program designed to ensure effective maintenance of the equipment most critical to plant safety. (author)

  7. Flight Crew Health Maintenance

    Science.gov (United States)

    Gullett, C. C.

    1970-01-01

    The health maintenance program for commercial flight crew personnel includes diet, weight control, and exercise to prevent heart disease development and disability grounding. The very high correlation between hypertension and overweight in cardiovascular diseases significantly influences the prognosis for a coronary prone individual and results in a high rejection rate of active military pilots applying for civilian jobs. In addition to physical fitness the major items stressed in pilot selection are: emotional maturity, glucose tolerance, and family health history.

  8. Opportune maintenance and predictive maintenance decision support

    OpenAIRE

    Thomas , Edouard; Levrat , Eric; Iung , Benoît; Cocheteux , Pierre

    2009-01-01

    International audience; Conventional maintenance strategies on a single component are being phased out in favour of more predictive maintenance actions. These new kinds of actions are performed in order to control the global performances of the whole industrial system. They are anticipative in nature, which allows a maintenance expert to consider non-already-planned maintenance actions. Two questions naturally emerge: when to perform a predictive maintenance action; how a maintenance expert c...

  9. Influence of the 100% w/v perfluorooctyl bromide (PFOB) emulsion dose on tumour radiosensitivity

    International Nuclear Information System (INIS)

    Thomas, C.; Guichard, M.; Riess, J.

    1991-01-01

    The radiosensitizing effect of a 100% w/v emulsion of a fluuorocarbon PFOB, which carries 4 times more oxygen than Fluosol-DA 20% emulsion, was studied on two human tumour xenografts (HRT18 and HT29) and murine tumour EMT6. This effect was compared to that of carbogen alone. The fluorocrit (amount of fluorocarbon in the blood) and haematocrit remained unchanged from 7 to 65 min post-injection of the emulsion (8ml/kg). Significant tumour radiosensitization was obtained with relatively low amounts of 100% w/v concentrated emulsion of PFOB plus carbogen. Maximum radiosensitization occurs at low fluorocarbon dose of about 3g/kg. These results are comparable to those obtained with Fluosol-DA 20% or Therox emulsion. Since this radiosensitization occurs only at relatively low fluorocrit without haematocrit modification, the oxygen-carrying capacity of the fluorocarbon is not the only factor involved in radiosensitization of tumor cells, regardless of the effect of carbogen on radiosensitivity. (author)

  10. Influence trend of temperature distribution in skin tissue generated by different exposure dose pulse laser

    Science.gov (United States)

    Shan, Ning; Wang, Zhijing; Liu, Xia

    2014-11-01

    Laser is widely applied in military and medicine fields because of its excellent capability. In order to effectively defend excess damage by laser, the thermal processing theory of skin tissue generated by laser should be carried out. The heating rate and thermal damage area should be studied. The mathematics model of bio-tissue heat transfer that is irradiated by laser is analyzed. And boundary conditions of bio-tissue are discussed. Three layer FEM grid model of bio-tissue is established. The temperature rising inducing by pulse laser in the tissue is modeled numerically by adopting ANSYS software. The changing trend of temperature in the tissue is imitated and studied under the conditions of different exposure dose pulse laser. The results show that temperature rising in the tissue depends on the parameters of pulse laser largely. In the same conditions, the pulse width of laser is smaller and its instant power is higher. And temperature rising effect in the tissue is very clear. On the contrary, temperature rising effect in the tissue is lower. The cooling time inducing by temperature rising effect in the tissue is longer along with pulse separation of laser is bigger. And the temperature difference is bigger in the pulse period.

  11. Network maintenance

    CERN Multimedia

    GS Department

    2009-01-01

    A site-wide network maintenance operation has been scheduled for Saturday 28 February. Most of the network devices of the general purpose network will be upgraded to a newer software version, in order to improve our network monitoring capabilities. This will result in a series of short (2-5 minutes) random interruptions everywhere on the CERN sites throughout the day. This upgrade will not affect the Computer Centre itself, Building 613, the Technical Network and the LHC experiments, dedicated networks at the pits. For further details of this intervention, please contact Netops by phone 74927 or e-mail mailto:Netops@cern.ch. IT/CS Group

  12. Network maintenance

    CERN Multimedia

    IT Department

    2009-01-01

    A site wide network maintenance has been scheduled for Saturday 28 February. Most of the network devices of the General Purpose network will be upgraded to a newer software version, in order to improve our network monitoring capabilities. This will result in a series of short (2-5 minutes) random interruptions everywhere on the CERN sites along this day. This upgrade will not affect: the Computer centre itself, building 613, the Technical Network and the LHC experiments dedicated networks at the pits. Should you need more details on this intervention, please contact Netops by phone 74927 or email mailto:Netops@cern.ch. IT/CS Group

  13. A single dose of lysergic acid diethylamide influences gene expression patterns within the mammalian brain.

    Science.gov (United States)

    Nichols, Charles D; Sanders-Bush, Elaine

    2002-05-01

    Hallucinogenic drugs such as lysergic acid diethylamide (LSD) have profound effects on humans including hallucinations and detachment from reality. These remarkable behavioral effects have many similarities to the debilitating symptoms of neuropsychiatric disorders such as schizophrenia. The effects of hallucinogens are thought to be mediated by serotonin receptor activation; however, how these drugs elicit the unusual behavioral effects remains largely a mystery, despite much research. We have undertaken the first comprehensive analysis of gene expression influenced by acute LSD administration in the mammalian brain. These studies represent a novel approach to elucidate the mechanism of action of this class of drugs. We have identified a number of genes that are predicted to be involved in the processes of synaptic plasticity, glutamatergic signaling and cytoskeletal architecture. Understanding these molecular events will lead to new insights into the etiology of disorders whose behavioral symptoms resemble the temporary effects of hallucinogenic drugs, and also may ultimately result in new therapies.

  14. Influence of lead apron shielding on absorbed doses from panoramic radiography.

    Science.gov (United States)

    Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D

    2013-01-01

    This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO(®) full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA(®) three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax(®) 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = -0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.

  15. Influence of the chemical composition of human tissues on dose distributions in hadron-therapy

    International Nuclear Information System (INIS)

    Batin, E.

    2008-06-01

    To compute the dose distribution, treatment planning systems require the exact anatomical location of tissues provided by computed tomography (CT) and the exact range of hadron beams in tissues based on the water equivalent ratio (WER). Since CT numbers are determined with x-rays and with an energy different from that used in hadron-therapy, a relation between CT numbers and the WER must to be established. We propose a determination of the WER with a Monte-Carlo simulation (GEANT4). We have determined the WER for 76 human tissues for a 135 MeV proton beam and for a 290 MeV/A carbon beam. The difference between the stoichiometric calibration and the simulated WER is lower than 1%. An additional 2% uncertainty that arises from the uncertainty in the CT numbers measurement should also be considered. The calculated WER were used to convert the deposited energy curve into the human tissue deposited energy curve for a 135 MeV proton beam and for a 290 MeV/A carbon beam. For both beams, the difference between the rescaled Bragg peak location and the one from the simulated curve is lower than 0.5 mm over the whole range of CT numbers. The differences between the maximum deposited energy can reach 3% for the proton beam in bones and vary between 1.5% and 3.5% for all tissues for the carbon beam. The scaling in two dimensions can be improved by using an additional factor that takes the scattering into account. (author)

  16. Electiveness of photorepair, influence of dark-repair on shape of dose-response curves, and high-dose decline, in UV-induced colour mutations of Serratia

    International Nuclear Information System (INIS)

    Kaplan, R.W.

    1978-01-01

    Strain CV of Serratia marcescens mutates by UV with high frequency to 3 groups of mutants (w, h, s) differing in colour from the red wild-type. The mutational dose-response curve has a curvature corresponding to about 3 hits. It reaches a peak and declines at high doses. Inactivation curves have a broad shoulder and mostly, but not always, a break to a lesser slope at UV doses near the peak of mutations. Photo reactivation (PR) gives a dose reduction of about 2 for both inactivation and mutation including the break and peak. The dose curve with PR for w-mutations shows 1 hit-, the other types 2-hit curvature leading to a change of mutation spectrum with dose due to PR. The UV-sensitive mutant uvs21 of CV has a survival curve with a small shoulder and a long upward concavity without a break, and the mutation curve is of the one-hit type without a peak and decline. PR gives a dose reduction of 12 for inactivation and of 7.5 for mutation. The 3-hit mutation curve of CV is interpreted by assuming that 2 further hits are required to protect the 1-hit pre-mutations from being abolished by the repair lacking in uvs21. UV induction of SOS repair cannot be responsible for the 3-hit curvature because UVR of phages and induction of prophage are already saturated at rather low doses. As high-dose decline is not observed in uvs21, possibly the non-mutagenic repair lacking from uvs21 interferes with the mutation finishing processes at high doses in the repair-proficient strain CV. However, UV induction of this interference cannot be a one-hit process but requires a very large number of hits. (Auth.)

  17. SU-F-T-452: Influence of Dose Calculation Algorithm and Heterogeneity Correction On Risk Categorization of Patients with Cardiac Implanted Electronic Devices Undergoing Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, P; Lins, L Nadler [AC Camargo Cancer Center, Sao Paulo (Brazil)

    2016-06-15

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT or IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.

  18. SU-F-T-452: Influence of Dose Calculation Algorithm and Heterogeneity Correction On Risk Categorization of Patients with Cardiac Implanted Electronic Devices Undergoing Radiotherapy

    International Nuclear Information System (INIS)

    Iwai, P; Lins, L Nadler

    2016-01-01

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT or IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.

  19. Influence of photon beam energy on the dose enhancement factor caused by gold and silver nanoparticles: An experimental approach

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, Eder José, E-mail: ederguidelli@pg.ffclrp.usp.br; Baffa, Oswaldo [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Av. Bandeirantes, 3900, 14040-901 Ribeirão Preto, SP (Brazil)

    2014-03-15

    Purpose: Noble metal nanoparticles have found several medical applications in the areas of radiation detection; x-ray contrast agents and cancer radiation therapy. Based on computational methods, many papers have reported the nanoparticle effect on the dose deposition in the surrounding medium. Here the authors report experimental results on how silver and gold nanoparticles affect the dose deposition in alanine dosimeters containing several concentrations of silver and gold nanoparticles, for five different beam energies, using electron spin resonance spectroscopy (ESR). Methods: The authors produced alanine dosimeters containing several mass percentage of silver and gold nanoparticles. Nanoparticle sizes were measured by dynamic light scattering and by transmission electron microscopy. The authors determined the dose enhancement factor (DEF) theoretically, using a widely accepted method, and experimentally, using ESR spectroscopy. Results: The DEF is governed by nanoparticle concentration, size, and position in the alanine matrix. Samples containing gold nanoparticles afford a DEF higher than 1.0, because gold nanoparticle size is homogeneous for all gold concentrations utilized. For samples containing silver particles, the silver mass percentage governs the nanoparticles size, which, in turns, modifies nanoparticle position in the alanine dosimeters. In this sense, DEF decreases for dosimeters containing large and segregated particles. The influence of nanoparticle size-position is more noticeable for dosimeters irradiated with higher beam energies, and dosimeters containing large and segregated particles become less sensitive than pure alanine (DEF < 1). Conclusions: ESR dosimetry gives the DEF in a medium containing metal nanoparticles, although particle concentration, size, and position are closely related in the system. Because this is also the case as in many real systems of materials containing inorganic nanoparticles, ESR is a valuable tool for

  20. Insulin is essential for in vitro chondrogenesis of mesenchymal progenitor cells and influences chondrogenesis in a dose-dependent manner.

    Science.gov (United States)

    Mueller, Michael B; Blunk, Torsten; Appel, Bernhard; Maschke, Angelika; Goepferich, Achim; Zellner, Johannes; Englert, Carsten; Prantl, Lukas; Kujat, Richard; Nerlich, Michael; Angele, Peter

    2013-01-01

    Insulin is a commonly used additive in chondrogenic media for differentiating mesenchymal stem cells (MSCs). The indispensability of other bioactive factors like TGF-β or dexamethasone in these medium formulations has been shown, but the role of insulin is unclear. The purpose of this study was to investigate whether insulin is essential for MSC chondrogenesis and if there is a dose-dependent effect of insulin on MSC chondrogenesis. We cultivated human MSCs in pellet culture in serum-free chondrogenic medium with insulin concentrations between 0 and 50 μg/ml and assessed the grade of chondrogenic differentiation by histological evaluation and determination of glycosaminoglycan (GAG), total collagen and DNA content. We further tested whether insulin can be delivered in an amount sufficient for MSC chondrogenesis via a drug delivery system in insulin-free medium. Chondrogenesis was not induced by standard chondrogenic medium without insulin and the expression of cartilage differentiation markers was dose-dependent at insulin concentrations between 0 and 10 μg/ml. An insulin concentration of 50 μg/ml had no additional effect compared with 10 μg/ml. Insulin was delivered by a release system into the cell culture under insulin-free conditions in an amount sufficient to induce chondrogenesis. Insulin is essential for MSC chondrogenesis in this system and chondrogenic differentiation is influenced by insulin in a dose-dependent manner. Insulin can be provided in a sufficient amount by a drug delivery system. Therefore, insulin is a suitable and inexpensive indicator substance for testing drug release systems in vitro.

  1. Influence of photon beam energy on the dose enhancement factor caused by gold and silver nanoparticles: An experimental approach

    International Nuclear Information System (INIS)

    Guidelli, Eder José; Baffa, Oswaldo

    2014-01-01

    Purpose: Noble metal nanoparticles have found several medical applications in the areas of radiation detection; x-ray contrast agents and cancer radiation therapy. Based on computational methods, many papers have reported the nanoparticle effect on the dose deposition in the surrounding medium. Here the authors report experimental results on how silver and gold nanoparticles affect the dose deposition in alanine dosimeters containing several concentrations of silver and gold nanoparticles, for five different beam energies, using electron spin resonance spectroscopy (ESR). Methods: The authors produced alanine dosimeters containing several mass percentage of silver and gold nanoparticles. Nanoparticle sizes were measured by dynamic light scattering and by transmission electron microscopy. The authors determined the dose enhancement factor (DEF) theoretically, using a widely accepted method, and experimentally, using ESR spectroscopy. Results: The DEF is governed by nanoparticle concentration, size, and position in the alanine matrix. Samples containing gold nanoparticles afford a DEF higher than 1.0, because gold nanoparticle size is homogeneous for all gold concentrations utilized. For samples containing silver particles, the silver mass percentage governs the nanoparticles size, which, in turns, modifies nanoparticle position in the alanine dosimeters. In this sense, DEF decreases for dosimeters containing large and segregated particles. The influence of nanoparticle size-position is more noticeable for dosimeters irradiated with higher beam energies, and dosimeters containing large and segregated particles become less sensitive than pure alanine (DEF < 1). Conclusions: ESR dosimetry gives the DEF in a medium containing metal nanoparticles, although particle concentration, size, and position are closely related in the system. Because this is also the case as in many real systems of materials containing inorganic nanoparticles, ESR is a valuable tool for

  2. Influence of Silicon on Swelling and Microstructure in Russian Austenitic Stainless Steels Irradiated to High Neutron Doses

    International Nuclear Information System (INIS)

    Porollo, S.I.; Shulepin, S.V.; Konobeev, Y.V.; Garner, F.

    2007-01-01

    Full text of publication follows: For some applications in fusion devices austenitic stainless steels are still considered to be candidates for use as structural components, but high neutron exposures must be endured by the steels. Operational experience of fast reactors in Western Europe, USA and Japan provides evidence of the possible use of austenitic steels up to ∼ 150 dpa. Studies aimed at improvement of existing Russian austenitic steels are being carried out in Russia. For improvement of irradiation resistance of Russian steels it is necessary to understand the basic mechanisms responsible for deterioration of steel properties. This understanding can be achieved by continuing detailed investigations of the microstructure of cladding steels after irradiation to high doses. By investigating the evolution of radiation-induced microstructure in neutron irradiated steels of different chemical composition one can study the effect of chemical variations on steel properties. Silicon is one of the most important chemical elements that strongly influence the behavior of austenitic steel properties under irradiation. In this paper results are presented of investigations of the effect of silicon additions on void swelling and microstructure of base austenitic stainless steel EI-847 (0.06C-16Cr-15Ni- 3Mo-Nb) irradiated as fuel pin cladding of both regular and experimental assemblies in the BOR-60, BN-350 and BN-600 fast reactors to neutron doses up to 49 dpa. The possible mechanisms of silicon's effect on void swelling in austenitic stainless steels are presented and analyzed. (authors)

  3. Optimization of radiation protection of cell maintenance of radiopharmaceutical production

    International Nuclear Information System (INIS)

    Machado, Jessica S.; Gerulis, Eduardo; Todo, Alberto S.; Rodrigues Junior, Orlando

    2011-01-01

    This paper performs a study of maintenance tasks realized in production cells to suggest improvements related to the occupational doses based on the optimization principle of the radioprotection. A data survey has been realized of the doses received by the workers during the maintenance. The average values of effective doses are lower than the limits established in the regulations, however can be optimized

  4. A HEALTHY DOSE OF PESSIMISM? INFLUENCE OF THE UKRAINIAN ECONOMY ON ITS BANKING SECTOR CREDIT RATINGS

    Directory of Open Access Journals (Sweden)

    Svitlana Pokrason

    2017-09-01

    Full Text Available The purpose of the research is to identify the influence of Ukraine’s economic development on the international agencies' credit rating of its banking system. The instability and ambiguous geopolitical position of Ukraine are complicating any predictions for its economic developments. In the meanwhile, massive restructuring of all sectors of the economy became the necessary minimum for the reformation of the country and the achievement of the international standards. It is interesting to see how exactly these international standards, as represented by the evaluation of the rating agencies, appraise Ukraine, and particularly its banking sector. The methodology involves the analysis of the three major Ukrainian banks – PrivatBank, Oschadbank, and Ukreximbank using Fitch’s credit quality assessment systematic as an example. The comparative analysis was performed using Tier 1 capital ratio and loan-to-deposit ratio of these banks, year-to-year quarterly GDP growth, consumer price index (CPI year-to-year change, UAH/USD exchange rate, 2-year and 5-year government bond yield, as well as 2-year and 5-year credit default swap (CDS. Results show that the most influential credit rating drivers for Ukrainian banks are: exchange rate; funding and liquidity; capital position and asset quality; sovereign risk. The research showed that the 2-year and 5-year government bond yield in USD and 2-year and 5-year CDS were influenced by similar trends. The yield on short-dated Ukrainian governmental bonds has shown a parallel increase with the corresponding CDS that indicated the market’s evaluation of the stressed condition of the country’s government and economy. Additionally, conventional yield structures displayed inversed nature with 2-year governmental bond yield in USD trading at significantly higher yields than 5-year government bond yield in USD during times of economic distress. Although longer maturity instruments should usually trade at a higher

  5. Influence of Renal Impairment on the Pharmacokinetics of Afatinib: An Open-Label, Single-Dose Study.

    Science.gov (United States)

    Wiebe, Sabrina; Schnell, David; Külzer, Raimund; Gansser, Dietmar; Weber, Anne; Wallenstein, Gudrun; Halabi, Atef; Conrad, Anja; Wind, Sven

    2017-06-01

    Afatinib is an oral irreversible ErbB-Family Blocker indicated for treatment of patients with EGFR mutation positive advanced non-small cell lung cancer. This trial assessed whether renal impairment influences the pharmacokinetics and safety of afatinib. This was an open-label, single-dose study. Pharmacokinetic parameters after afatinib 40 mg were investigated in subjects with moderate (n = 8) or severe (n = 8) renal impairment (estimated glomerular filtration rate 30-59 mL/min/1.73 m 2 and 15-29 mL/min/1.73 m 2 , respectively) and healthy matched controls (n = 14). Plasma and urine samples were collected before and up to 14 days after dosing for pharmacokinetic and plasma protein-binding assessment. Primary endpoints were area under the plasma concentration-time curve from time zero to the last quantifiable concentration (AUC last ) and maximum plasma concentration (C max ) between subjects with renal impairment and healthy matched controls. Pharmacokinetic profiles and plasma protein binding were similar in all groups. The extent of exposure, as indicated by AUC last and C max , was generally similar between the matched treatment groups, with the exception of the geometric mean ratio of AUC last for subjects with severe renal impairment, which showed a trend towards a higher value compared with matched healthy subjects (150.0 % [90 % CI 105.3-213.7]) Inter-individual variability was moderate (geometric mean coefficient of variation 28-39 % for moderate impairment, 34-42 % for severe impairment). Afatinib was well tolerated and urinary excretion was minimal. Moderate-to-severe renal impairment had a minor influence on the pharmacokinetics of afatinib that was within the observed inter-individual variability, suggesting that afatinib treatment can be considered in this patient population. Registered at ClinicalTrials.gov as NCT02096718.

  6. Influence of dose, dose rate, and radiation quality on radiation carcinogenesis and life shortening in RFM and BALB/C mice

    International Nuclear Information System (INIS)

    Ullrich, R.L.; Storer, J.B.

    1978-01-01

    The effects produced by 137 Cs gamma rays delivered at a high (45 rads/min) or intermediate (8.2 rads/day) dose rate and the effect of fission neutrons at a high (25 rads/min) and low (1 rad/day) rate in a population of nearly 30,000 RFM and 11,000 BALB/c mice have been studied. Gamma ray doses ranged from 10 to 400 rads with the RFM's and from 50-400 rads with the BALB/c's, while neutron doses ranged from 5 to 200 rads with both strains. The present paper will present an overview of these data and the general findings while subsequent publications will present detailed analyses of each aspect. A variety of neoplasms were sensitive to induction after radiation exposure, including tumors of both reticular tissue origin (leukemia, lymphoma, etc.) and solid tumors. For the RFM, thymic lymphomas were the dominant reticular tissue neoplasm while the majority of solid tumors were either lung adenomas or fit into the broad category of endocrine related tumors, including ovarian, pituitary, harderian, and uterine tumors. The BALB/c was much less sensitive to induction of reticular tissue neoplasms. The tumors that were most sensitive to induction included malignant lung carcinomas, mammary adenocarcinomas and ovarian tumors. In general for both life shortening and tumor induction after gamma ray exposures, when the low to intermediate dose range was sufficiently defined, linearity could be rejected and a dose squared or linear-dose squared relationship adequately fit the data. For neutron exposures, on the other hand, linear relationships were the general finding. The RBE for neutrons varied with tumor type and total dose level. For gamma ray irradiation, the intermediate dose rate resulted in a decreased effectiveness in all cases, while for neutron exposures the dose rate relationships were more complex

  7. Influence of control group therapy on the benefit from dose-dense chemotherapy in early breast cancer: a systemic review and meta-analysis.

    Science.gov (United States)

    Goldvaser, Hadar; Majeed, Habeeb; Ribnikar, Domen; Šeruga, Boštjan; Ocaña, Alberto; Cescon, David W; Amir, Eitan

    2018-02-08

    Results from clinical trials of adjuvant dose-dense chemotherapy in patients with breast cancer are inconsistent. A systematic search of MEDLINE identified studies comparing the efficacy of dose-dense adjuvant chemotherapy to a standard treatment. The primary analysis included studies that used identical regimens in the experimental and control groups, but varied only dose density. A secondary analysis included studies that used either different drugs or doses in the experimental and the control groups. Hazard ratios (HRs) and 95% confidence intervals were computed for disease-free survival (DFS) and overall survival (OS) and pooled in a meta-analysis. Subgroup analyses and meta-regression explored drug schedules utilized in control groups and the influence of clinicopathologic variables on benefit from dose-dense therapy. The primary analysis included 5 studies comprising 9819 patients while the secondary analysis included 6 studies comprising 9679 patients. Dose-dense treatment significantly improved DFS (HR 0.85, p benefit was observed in pre-menopausal women and those with nodal involvement, but there was no influence of hormone receptor status on results. Adjuvant dose-dense regimens improve breast cancer outcomes. It remains uncertain whether the observed benefit reflects the impact of dose density or the inferiority of paclitaxel every 3 weeks as a control group.

  8. Exposure control during high maintenance jobs

    International Nuclear Information System (INIS)

    Hinson, C.S.; Wigginton, J.E.

    1991-01-01

    Occupational radiation doses at US light-water-cooled reactors (LWRs) have been decreasing every year since 1983. In 1989, the LWR average dose per reactor reached its lowest point since 1973. Historically, maintenance-related activities have accounted for between 70 and 75% of the total occupational doses at US LWRs, and most of this maintenance-related dose is accrued during plant outages. This paper will focus on high dose maintenance jobs such as steam generator replacement, recirculation pipe replacement/crack repair, induction heating stress improvement, and steam generator tube plugging/sleeving and will discuss how the doses associated with these jobs have declined over the past several years through the implementation of various ALARA techniques

  9. Factors influencing the success of radio-iodine dose in the treatment of Graves disease: one year outcome

    International Nuclear Information System (INIS)

    Kamoun, T.; Sfar, R.; Regaieg, H.; Toumi, A.; Zanzouri, H.; Nouira, M.; Ben Fredj, M.; Ayachi, N.; Chatti, K.; Guezguez, M.; Essabbah, H.; Sakly, N.

    2015-01-01

    Full text of publication follows. Aim: radioiodine ( 131 I) is increasingly used as the definitive treatment of Graves disease (GD). Many factors influence the curative effects of the 131 I, thus there are some difficulties to define the optimal dose of 131 I for the treatment of GD. The purpose of our study is to evaluate the factors influencing the success rate in patients having GD and treated with radioiodine dose modulated by thyroid mass. Materials and methods: this is a prospective study of 86 patients (aged 43 ± 11, 58 women and 28 men) treated for Graves disease by radioiodine during the year 2011 in Nuclear Medicine department CHU Sahloul, Sousse. Radioiodine dose are modulated by thyroid mass: 370 MBq, 444 MBq and 555 MBq respectively for mass strictly less than 30 g, between 30 g and 40 g and greater than to 40 g. Some patients received more than 555 MBq for other causes to reach hypothyroidism precociously. The thyroid function outcome (hyperthyroidism or euthyroidism/hypothyroidism) was verified 6 months and 1 year after 131 I treatment. Patient gender, age, ophthalmopathy, thyroid size, antithyroid drugs used prior to 131 I treatment and anti-TSH receptor antibodies (TRAb), anti-thyroid peroxidase antibodies (ATPO) and anti-thyroglobulin antibodies (ATG) plasma concentrations before 131 I treatment were studied as potential interference factors for 131 I treatment success. Results: Thirty patients received 370 MBq, 29 received 444 MBq, 14 received 555 MBq and 13 more than 555 MBq. Outcome after treatment was determined in a total of 66 patients at 6 months and 63 at one year. Post-therapy follow-up revealed that treatment failed in 29% of the patients at 6 months and in 20% of patients at one year. No correlation was noted between the outcome of treatment and age, sex, ophthalmopathy, antithyroid drugs taking and ATG titer. A significant correlation was noted between the disease outcome at one year and TRAb titer: High TRAb levels are associated

  10. Box modelling approach for evaluation of influence of ice transport of radionuclides for doses to man

    International Nuclear Information System (INIS)

    Iospje, M.

    2002-01-01

    Modelling of the ice transport of radionuclides, which is a unique pathway in the Arctic ocean and adjacent sea areas, is limited by necessity to describe complete processes of incorporation of radioactivity into ice and ice sediment. Freezing / melting processes and transport of 'clean' ice can be described with a good accuracy for relatively short time scale on the basis of the present level of modelling, but detailed description of the sediment entrainment into ice based on the Reynolds equations with attention to coagulation processes is limited by low concentration of particles (grease ice cannot be described) and time scale up to 5 . 10 -2 s (1 . 10 -9 y) what is not available for large time scale and ice masses. Adding the radioactivity incorporation into the ice with following description of transport and fate of radionuclides will lead to further increasing of the complexity of the modelling. Therefore, it is necessary to develop an alternative approach for purposes of radiological assessment on the basis of the box modelling to describe the incorporation of radioactivity into ice and ice sediment, transport of radioactivity by ice and incorporation of radioactivity into sea areas through melding processes. It is shown that the ice transport of radionuclides can be a significant factor for some scenarios and radionuclides. The influence of the ice transport increases with increasing K d values for radionuclides. It is necessary to note that the content and structure of the sediment load in ice vary within wide limits, and therefore, sensitivity and uncertainty analysis can improve the possibility to represent model results satisfactorily. (LN)

  11. Influences of hand dominance on the maintenance of benefits after home-based modified constraint-induced movement therapy in individuals with stroke

    Directory of Open Access Journals (Sweden)

    Renata C. M. Lima

    2014-10-01

    Full Text Available Objective: To investigate the influence of hand dominance on the maintenance of gains after home-based modified constraint-induced movement therapy (mCIMT. Method: Aprevious randomized controlled trial was conducted to examine the addition of trunk restraint to the mCIMT. Twenty-two chronic stroke survivors with mild to moderate motor impairments received individual home-based mCIMT with or without trunk restraints, five times per week, three hours daily over two weeks. In this study, the participants were separated into dominant group, which had their paretic upper limb as dominant before the stroke (n=8, and non-dominant group (n=14 for analyses. The ability to perform unimanual tasks was measured by the Wolf Motor Function Test (WMFT and the Motor Activity Log (MAL, whereas the capacity to perform bimanual tasks was measured using the Bilateral Activity Assessment Scale (BAAS. Results: Analysis revealed significant positive effects on the MAL amount of use and quality of the movement scales, as well as on the BAAS scores after intervention, with no differences between groups. Both groups maintained the bimanual improvements during follow-ups (BAAS-seconds 0.1, 95% CI -10.0 to 10.0, however only the dominant group maintained the unilateral improvements (MAL-amount of use: 1.5, 95% CI 0.7 to 2.3; MAL-quality: 1.3, 95% CI 0.5 to 2.1. Conclusions: Upper limb dominance did not interfere with the acquisition of upper limb skills after mCIMT. However, the participants whose paretic upper limb was dominant demonstrated better abilities to maintain the unilateral gains. The bilateral improvements were maintained, regardless of upper limb dominance.

  12. Optimizing preventive maintenance with maintenance templates

    International Nuclear Information System (INIS)

    Dozier, I.J.

    1996-01-01

    Rising operating costs has caused maintenance professionals to rethink their strategy for preventive maintenance (PM) programs. Maintenance Templates are pre-engineered PM task recommendations for a component type based on application of the component. Development of the maintenance template considers the dominant failure cause of the component and the type of preventive maintenance that can predict or prevent the failure from occurring. Maintenance template development also attempts to replace fixed frequency tasks with condition monitoring tasks such as vibration analysis or thermography. For those components that have fixed frequency PM intervals, consideration is given to the maintenance drivers such as criticality, environment and usage. This helps to maximize the PM frequency intervals and maximize the component availability. Maintenance Templates have been used at PECO Energy's Limerick Generating Station during the Reliability Centered Maintenance (RCM) Process to optimize their PM program. This paper describes the development and uses of the maintenance templates

  13. The influence of actuator materials and nozzle designs on electrostatic charge of pressurised metered dose inhaler (pMDI) formulations.

    Science.gov (United States)

    Chen, Yang; Young, Paul M; Fletcher, David F; Chan, Hak Kim; Long, Edward; Lewis, David; Church, Tanya; Traini, Daniela

    2014-05-01

    To investigate the influence of different actuator materials and nozzle designs on the electrostatic charge properties of a series of solution metered dose inhaler (pMDI) aerosols. Actuators were manufactured with flat and cone nozzle designs using five different materials from the triboelectric series (Nylon, Polyethylene terephthalate, Polyethylene-High density, Polypropylene copolymer and Polytetrafluoroethylene). The electrostatic charge profiles of pMDI containing beclomethasone dipropionate (BDP) as model drug in HFA-134a propellant, with different concentrations of ethanol were studied. Electrostatic measurements were taken using a modified electrical low-pressure impactor (ELPI) and the deposited drug mass assayed chemically using HPLC. The charge profiles of HFA 134a alone have shown strong electronegativity with all actuator materials and nozzle designs, at an average of -1531.34 pC ± 377.34. The presence of co-solvent ethanol significantly reduced the negative charge magnitude. BDP reduced the suppressing effect of ethanol on the negative charging of the propellant. For all tested formulations, the flat nozzle design showed no significant differences in net charge between different actuator materials, whereas the charge profiles of cone designs followed the triboelectric series. The electrostatic charging profiles from a solution pMDI containing BDP and ethanol can be significantly influenced by the actuator material, nozzle design and formulation components. Ethanol concentration appears to have the most significant impact. Furthermore, BDP interactions with ethanol and HFA have an influence on the electrostatic charge of aerosols. By choosing different combinations of actuator materials and orifice design, the fine particle fractions of formulations can be altered.

  14. Influence of pre-hydration and pharmacogenetics on plasma methotrexate concentration and renal dysfunction following high-dose methotrexate therapy.

    Science.gov (United States)

    Yanagimachi, Masakatsu; Goto, Hiroaki; Kaneko, Tetsuji; Naruto, Takuya; Sasaki, Koji; Takeuchi, Masanobu; Tanoshima, Reo; Kato, Hiromi; Yokosuka, Tomoko; Kajiwara, Ryosuke; Fujii, Hisaki; Tanaka, Fumiko; Goto, Shoko; Takahashi, Hiroyuki; Mori, Masaaki; Kai, Sumio; Yokota, Shumpei

    2013-12-01

    High-dose methotrexate therapy (HD-MTX) has been well established for the treatment of childhood acute lymphoblastic leukemia (ALL). The aims of this study were to investigate whether clinical and pharmacogenetic factors influence plasma MTX concentration and renal dysfunction in patients treated with HD-MTX. In a total of 127 courses of HD-MTX in 51 patients with childhood ALL, influence of clinical and pharmacogenetic factors on plasma MTX concentration and HD-MTX-related renal dysfunction was evaluated. Clinical factors included age, gender, duration of HD-MTX continuous-infusion and duration of pre-hydration before HD-MTX. Pharmacogenetic factors included 5 gene polymorphisms within the MTX pathway genes, namely, SLC19A1, MTHFR, ABCC2 and ABCG2. Short duration of pre-hydration before HD-MTX is the most important risk factor for prolonged high MTX concentration (p < 0.001, OR 6.40, 95 % CI 2.39-17.16) and renal dysfunction (p = 0.013, OR 3.15, 95 % CI 1.27-7.80). The T allele at MTHFR C677T was the risk factor for prolonged high MTX concentration (p = 0.009, OR 5.54, 95 % CI 1.54-19.85), but not for renal dysfunction. We found the influence of MTHFR C677T polymorphism on prolonged high MTX concentration. We reconfirmed the importance of adequate pre-hydration before HD-MTX to prevent prolonged high MTX concentration and MTX-related renal dysfunction.

  15. Maintenance in sustainable manufacturing

    Directory of Open Access Journals (Sweden)

    Vladimir Stuchly

    2014-09-01

    Full Text Available Background: Sustainable development is about reaching a balance between economic, social, and environmental goals, as well as people's participation in the planning process in order to gain their input and support. For a company, sustainable development means adoption of such business strategy and actions that contribute to satisfying present needs of company and stakeholders, as well as simultaneous protection, maintenance and strengthening of human and environmental potential which will be needed in the future. This new approach forces manufacturing companies to change their previous management paradigms. New management paradigm should include new issues and develop innovative methods, practices and technologies striving for solving problem of shortages of resources, softening environment overload and enabling development of environment-friendly lifecycle of products. Hence, its realization requires updating existing production models as they are based on previously accepted paradigm of unlimited resources and unlimited regeneration capabilities. Maintenance plays a crucial role because of its impact on availability, reliability, quality and life cycle cost, thus it should be one of the main pillars of new business running model.  Material and methods: The following paper is a result of research on the literature and observation of practices undertaken by a company within maintenance area. Results and conclusions: The main message is that considering sustainable manufacturing requires considerable expanding range of analysis and focusing on supporting processes. Maintenance offers numerous opportunities of decreasing influence of business processes on natural environment and more efficient resources utilization. The goal of maintenance processes realizing sustainable development strategy is increased profitability of exploitation and optimization of total lifecycle cost without disturbing safety and environmental issues. 

  16. Physiological effects of low doses of Cerastes cerastes crude venom and its influence on doxorubicin treated rats

    International Nuclear Information System (INIS)

    AL-Sadoon, M. K.; Salama, S. F.

    2012-01-01

    The purpose of this study was to investigate the effects of C. cerastes crude venom (CCV) and its influence on doxorubicin (DOX) treated male rats. Thirty two male rats were arranged into four equal groups, control, CCV-group, DOX-group and CCV + DOX-groups. Control group was injected intraperitoneally (i.p.) with saline for 10 days, while CCV-group was injected i.p. with crude CCV at a dose of . Ld50 for 10 days. DOX-group was injected i.p. with DOX at a dose of 2.5 mg/kg body weight for 10 days. CCV + DOX-group was injected i.p. with 2.5 mg/kg daily of DOX and CCV . Ld50 for 10 days. In the CCV group, significant decrease in contents of serum advanced oxidation protein products (AOPP) and malondialdehyde (MDA) as well as significant increase in blood reduced glutathione (GSH), red blood cells (RBCs), platelet counts, hemoglobin content (Hb), hematocrit value (Hct), total leukocyte, neutrophil, lymphocyte counts and relative spleen weight (RSW) were recorded. In DOX- group, a significant increase in contents of serum AOPP and MDA besides a significant decrease in GSH, Hb, Hct, RBCs, platelet counts, , total leukocytes, neutrophils, lymphocytes counts and RSW were recorded. In DOX+ CCV- group, a significant decrease of the serum AOPP and MDA in addition to a significant increase of GSH, RBCs, platelets counts, Hb and Hct were shown as compared with DOX- group, while the suppression of RSW, total leukocytes, neutrophils, lymphocytes counts and histological changes of spleen were non significantly alleviated

  17. Influence of UV dose on the UV/H2O2 process for the degradation of carbamazepine in wastewater.

    Science.gov (United States)

    Somathilake, Purnima; Dominic, John Albino; Achari, Gopal; Langford, Cooper H; Tay, Joo-Hwa

    2018-05-02

    This study evaluates the influence of UV dose on degradation of carbamazepine (CBZ) in wastewater under UV-C (λ = 254 nm) photolysis with and without H 2 O 2 . The rate of degradation of CBZ exhibited a direct dependence on the intensity of incident UV irradiation as the rate of degradation was observed to increase linearly (R 2  = 0.98) with UV intensity between 1.67 and 8.95 × 10 17 photons/s. More than 95% of the CBZ that spiked in wastewater rapidly degraded within 4 min with a first-order rate constant of 1.2 min -1 for an optimum H 2 O 2 dose of 100 mg/L. Bench-scale continuous flow reactor experiments also showed that CBZ degraded with first-order kinetics at a rate constant of 1.02 min -1 . The kinetic parameters obtained for a continuous bench-scale reactor were in good agreement with the relationships developed through batch experiments with only a marginal deviation of ± 6.5%. The relationship between UV intensity and CBZ degradation rate obtained in this study was extrapolated to the UV disinfection unit of a wastewater treatment plant to predict possible degradation of CBZ during UV disinfection. The addition of 100 mg/L of H 2 O 2 to the secondary-treated effluent entering the UV disinfection unit is predicted to achieve over 60% degradation of CBZ.

  18. Influence of polyvinylpyrrolidone, microcrystalline cellulose and colloidal silicon dioxide on technological characteristics of a high-dose Petiveria alliacea tablet.

    Science.gov (United States)

    García-Pérez, Martha-Estrella; Lemus-Rodríguez, Zoe; Hung-Arbelo, Mario; Vistel-Vigo, Marlen

    2017-12-01

    Petiveria alliacea L. (Phytolaccaceae) is a perennial shrub used by its immunomodulatory, anticancerogenic and anti-inflammatory properties. This study determined the influence of polyvinylpyrrolidone (PVP), colloidal silicon dioxide (CSD) and microcrystalline cellulose (MC) on the technological characteristic of a high-dose P. alliacea tablet prepared by the wet granulation method. The botanical and pharmacognostic analysis of the plant material was firstly performed, followed by a 2 3 factorial design considering three factors at two levels: (a) the binder (PVP) incorporated in formulation at 10% and 15% (w/w); (b) the compacting agent (CSD) added at 10% and 15% (w/w) and; (c) the diluent (MC) included at 7.33% and 12.46% (w/w). The analysis of pharmaceutical performance and the accelerated and long-term stability of the best prototype were also completed. The binder, compacting agent and the interaction binder/diluent had a significant impact on breaking force of high-dose P. alliacea tablet. The optimum formula was found to contain 15% (w/w) of CSD, 7.33% (w/w) of MC and 10% (w/w) of PVP. At these conditions, the tablet shows a breaking force of 77.96 N, a friability of 0.39%, a total phenol content of 1.30 mg/tablet and a maximum disintegration time of 6 min. The use of adequate amounts of PVP, MC and CSD as per the factorial design allowed the preparation of a tablet suitable for administration, despite the inappropriate flow and compressibility properties of the P. alliacea powder.

  19. Influence of energy dependence GafChromic XR-RV3 movies to the extent of skin dose

    International Nuclear Information System (INIS)

    Martinez Gomez, L. C.; Gilarranz Moreno, R.; Rot San Juan, M. J.; Delgado Rodriguez, J. M.; Adaimi Hernandez, P.; Milanes Gaillet, A.

    2013-01-01

    In this work we have evaluated uncertainties by comparing the calculated dose with films from a calibration reference with dose measurements ionization with chamber using beams in clinical conditions. (Author)

  20. Evaluation of ambient dose equivalent rates influenced by vertical and horizontal distribution of radioactive cesium in soil in Fukushima Prefecture

    OpenAIRE

    Malins, Alex; Kurikami, Hiroshi; Nakama, Shigeo; Saito, Tatsuo; Okumura, Masahiko; Machida, Masahiko; Kitamura, Akihiro

    2015-01-01

    The air dose rate in an environment contaminated with 134Cs and 137Cs depends on the amount, depth profile and horizontal distribution of these contaminants within the ground. This paper introduces and verifies a tool that models these variables and calculates ambient dose equivalent rates at 1 m above the ground. Good correlation is found between predicted dose rates and dose rates measured with survey meters in Fukushima Prefecture in areas contaminated with radiocesium from the Fukushima D...

  1. Population-related genetic aspects of the low doses radiological risk and melanin influence on genetic radiosensitivity

    International Nuclear Information System (INIS)

    Mosse, I.B.; Plotnikova, S.I.; Kostrova, L.N.; Subbot, S.T.; Maksymenia, I.P.; Dubovic, B.V.

    1997-01-01

    From the genetic point of view, radiation sensitivity is a quantitative character, and the distribution of individuals in the population with different radiation sensitivities is characterized by a binomial curve. Thus rise in irradiation dose first results in a very slow increase in the number of sensitive genotypes, and then in a sharp rise. Since quantitative characters are dependent on several polymeric genes, and their manifestation is strongly affected by external conditions, radiation sensitivity of the organism depends on many hereditary and environmental factors. One of them is the presence of melanin pigment in cells. In particular, we have shown that the introduction of exogenous melanin into the organisms of mice reduces (2-4 times) the frequency of mutations, induced not only by acute, but also by chronic irradiation. It was also established, that mutational load, accumulated in drosophila populations, irradiated within 125 generations, has been decreased under melanin influence almost to the control level. Antimutagenic action of melanin is also manifested on cultured human cells. So, it was shown by the example of melanin, that it is possible to increase the radiation resistance of individuals, and in the first place of the population highly sensitive fraction. (author)

  2. Influence of precipitations, buildings and over increase of radioactive emission in the population dose calculation under accident conditions

    International Nuclear Information System (INIS)

    Conte, M.C.

    1987-01-01

    The influence of precipitations is analyzed, as well as of buildings and emission over increase on the dosis produced on the population as a consequence of some postulated accidents in Atucha II nuclear power plant. The following conclusions were achieved: the calculations performed without considering the above mentioned effects are conservative, excluding the case in which the precipitation is very close to the emission source. In this case, the maximal difference observed was 20% for class C and 5% for class D, at 1 km from source, with a decreasing difference according to the distance. The doses calculated without building effect were approximately 25% greater than those calculated considering this effect for class E and 40% for class F, at 1 km from the source. The difference decreases with distance and increases with the stability of atmospheric conditions. This behaviour is also observed with the over increase effect. In this case, the maximal observed differences were of one order of magnitude for class E and three orders for class F, at 1 km from the source. (Author)

  3. Evaluation of the influence of parameters that determine the mean glandular dose in mammography using different detectors

    International Nuclear Information System (INIS)

    Costa, K.; Nogueira, M. S.

    2015-10-01

    Full text: Mammography is a test used for early detection of breast cancer. The mean glandular dose (MGD) is dosimetric greatness accepted as indicative of carcinogenic risk induced by ionizing radiation in the breasts of women undergoing mammography exams. MGD value is estimated from the incident air kerma (k i), associated with conversion factors which depend on the half-value layer (HVL), the breast composition and thickness compressed breast. This study aims to evaluate the influence of the parameters used to determine the MGD using different measurement detectors. Measurements were performed on a Siemens Mammomat Model 300 Nova mammography equipment; this has the combinations Anode/Filter of Mo/Mo, Mo/Rh and W/Rh. Detectors used were the ionization chamber Model 10X6-6M manufactured by Radcal Co., two solid-state detectors, one Model AGMS-M manufactured by Radcal Co. and other Model Xi Mammo manufactured by UNFORS. The detectors measures were compared and the MGD value was estimated; differences between measurements and the reference values were higher in HVL and k i parameters. The results are displayed according to other published works. (Author)

  4. Influence of patient positioning on heart and coronary doses in the context of radiotherapy for breast cancer

    International Nuclear Information System (INIS)

    Stoltenberg, Solveigh Liza

    2013-01-01

    In this thesis the doses of heart and coronaries as well as the lung dose have been evaluated in the context of patient positioning (prone (pp) and supine position (sp)) in 3D-conformal radiotherapy for breast cancer within 46 patients (33 left-sided, 13 right-sided cancers). The protection of lung tissue reported in various publications has been confirmed. On the other hand, there was no increase of heart dose to be seen in pp. Despite the lack of increase of heart dose in pp, an increase of LAD (left anterior descending)-dose has been detected.

  5. Computed tomography-based treatment planning for high-dose-rate brachytherapy using the tandem and ring applicator: influence of applicator choice on organ dose and inter-fraction adaptive planning

    Directory of Open Access Journals (Sweden)

    Vishruta A. Dumane

    2017-06-01

    Full Text Available Three dimensional planning for high-dose-rate (HDR brachytherapy in cervical cancer has been highly recommended by consensus guidelines such as the American Brachytherapy Society (ABS and the Groupe Européen de Curiethérapie – European Society for Radiotherapy and Oncology (GEC-ESTRO. In this document, we describe our experience with computed tomography (CT-based planning using the tandem/ring applicator. We discuss the influence of applicator geometry on doses to organs at risk (OARs, namely the bladder, rectum, and sigmoid. Through example cases with dose prescribed to point A, we demonstrate how adaptive planning can help achieve constraints to the OARs as per guidelines.

  6. The influence of folate pathway polymorphisms on high-dose methotrexaterelated toxicity and survival in children with non-Hodgkin malignant lymphoma

    Directory of Open Access Journals (Sweden)

    Erculj Nina

    2014-09-01

    Full Text Available Background. We evaluated the influence of folate pathway polymorphisms on high-dose methotrexate (HD-MTX related toxicity in paediatric patients with T-cell non-Hodgkin lymphoma (NHL. Patients and methods. In total, 30 NHL patients were genotyped for selected folate pathway polymorphisms.

  7. Influence of contrast materials on dose calculation in radiotherapy planning using computed tomography for tumors at various anatomical regions: A prospective study

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Naruse, Asaka; Fukuma, Hiroshi; Ayakawa, Shiho; Sugie, Chikao; Tomita, Natsuo

    2007-01-01

    Influences of iodinated contrast media on dose calculation were studied in 26 patients. Mean increases in monitor units by contrast media administration were less than 1% and considered negligible in planning of whole-brain, whole-neck, mediastinal, and whole-pelvic irradiation. However, mean increases over 2% were seen in planning of upper-abdominal radiotherapy

  8. Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (CBCT).

    Science.gov (United States)

    Schulze, Ralf Kurt Willy; Sazgar, Mahssa; Karle, Heiko; de Las Heras Gala, Hugo

    2017-08-01

    The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute and relative differences computed. Reproducibility was expressed as the coefficient of variation (CV) between the 10 repeated assessments. The highest doses observed at skin level were found at the thyroid (mean shielded ± SD: 450.5 ± 346.7 μGy; non-shielded: 339.2 ± 348.8 μGy, p = 0.4922). Shielding resulted in a highly significant (p < 0.001) 93% dose reduction in skin dose in the female breast region with a mean non-shielded dose of approximately 35 μGy. Dose reduction was also significantly lower for the back-region (mean: -65%, p < 0.0001) as well as for the gonad-region (mean: -98%, p < 0.0001) in the shielded situation. Reproducibility was inversely correlated to skin dose (Rspearman = -0.748, p < 0.0001) with a mean CV of 10.45% (SD: 24.53 %). Skin dose in the thyroid region of the simulated patient was relatively high and not influenced by the lead apron, which did not shield this region. Dose reduction by means of a commercial lead apron was significant in all other regions, particularly in the region of the female breast.

  9. Changes in activity of industrial enzyme preparations irradiated with sterilizing doses. Part of a coordinated programme on factors influencing the utilization of food irradiation process

    International Nuclear Information System (INIS)

    Bachman, S.

    1984-03-01

    Experiments were carried out to investigate the efficacy of irradiation to sterilize enzyme preparations. Irradiation doses up to 25 kGy caused no changes in basic organoleptic properties of commercial rennin preparations. Dose rate (from 0.5 to 13.5 kGy/hr) has no influence on the changes in enzyme activity during the storage period of 3 months. Doses ranging from 8 to 12 kGy are sufficient to sterilize commercial enzyme preparations. Non-purified, crude rennin preparations appear to be more resistant to radiation than purified samples. Rennin preparations purified by dialysis and treated with 25 kGy resulted in a reduction of activity of 20%. The activity of preparations purified by gel filtration was reduced to 50% when treated with the same dose

  10. Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Hong, Joo Wan; Jeong, Yun Ju; Won, Hui Su; Chang, Nam Jun; Choi, Ji Hun; Seok, Jin Yong

    2010-01-01

    There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1-2 minutes was no significant in the dose rate increases. From this study, when the dose rates increase, there was a significant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  11. Maintenance Business Plans.

    Science.gov (United States)

    Adams, Matt

    2002-01-01

    Discusses maintenance business plans, statements which provide accountability for facilities maintenance organizations' considerable budgets. Discusses the plan's components: statement of plan objectives, macro and detailed description of the facility assets, maintenance function descriptions, description of key performance indicators, milestone…

  12. Influence of length of interval between pulses in PDR brachytherapy (PDRBT on value of Biologically Equivalent Dose (BED in healthy tissues

    Directory of Open Access Journals (Sweden)

    Tomasz Piotrowski

    2010-07-01

    Full Text Available Purpose: Different PDR treatment schemas are used in clinical practice, however optimal length of interval between pulses still remains unclear. The aim of this work was to compare value of BED doses measured in surrounded healthy tissues according to different intervals between pulses in PDRBT. Influence of doses optimization on BED values was analyzed.Material and methods: Fifty-one patients treated in Greater Poland Cancer Centre were qualified for calculations.Calculations of doses were made in 51 patients with head and neck cancer, brain tumor, breast cancer, sarcoma, penis cancer and rectal cancer. Doses were calculated with the use of PLATO planning system in chosen critical points in surrounded healthy tissues. For all treatment plans the doses were compared using Biologically Equivalent Dose formula.Three interval lengths (1, 2 and 4 hours between pulses were chosen for calculations. For statistical analysis Friedman ANOVA test and Kendall ratio were used.Results: The median value of BED in chosen critical points in healthy tissues was statistically related to the length of interval between PDR pulses and decreased exponentially with 1 hour interval to 4 hours (Kendall = from 0.48 to 1.0; p = from 0.002 to 0.00001.Conclusions: Prolongation of intervals between pulses in PDR brachytherapy was connected with lower values of BED doses in healthy tissues. It seems that longer intervals between pulses reduced the risk of late complications, but also decreased the tumour control. Furthermore, optimization influenced the increase of doses in healthy tissues.

  13. The Circadian Schedule for Childhood Acute Lymphoblastic Leukemia Maintenance Therapy does not Influence Event-Free Survival in the NOPHO ALL92 Protocol

    DEFF Research Database (Denmark)

    Clemmensen, Kim K. B.; Christensen, Regitse H.; Shabaneh, Diana N.

    2014-01-01

    BACKGROUND: The event-free survival of childhood acute lymphoblastic leukemia (ALL) has been reported to be superior when oral methotrexate (MTX) and 6-mercaptopurine (6MP) maintenance therapy (MT) is administered in the evening compared to the morning. PROCEDURE: In the ALL92 MT study we prospec...

  14. Evaluation of the influence of double and triple Gaussian proton kernel models on accuracy of dose calculations for spot scanning technique.

    Science.gov (United States)

    Hirayama, Shusuke; Takayanagi, Taisuke; Fujii, Yusuke; Fujimoto, Rintaro; Fujitaka, Shinichiro; Umezawa, Masumi; Nagamine, Yoshihiko; Hosaka, Masahiro; Yasui, Keisuke; Omachi, Chihiro; Toshito, Toshiyuki

    2016-03-01

    The main purpose in this study was to present the results of beam modeling and how the authors systematically investigated the influence of double and triple Gaussian proton kernel models on the accuracy of dose calculations for spot scanning technique. The accuracy of calculations was important for treatment planning software (TPS) because the energy, spot position, and absolute dose had to be determined by TPS for the spot scanning technique. The dose distribution was calculated by convolving in-air fluence with the dose kernel. The dose kernel was the in-water 3D dose distribution of an infinitesimal pencil beam and consisted of an integral depth dose (IDD) and a lateral distribution. Accurate modeling of the low-dose region was important for spot scanning technique because the dose distribution was formed by cumulating hundreds or thousands of delivered beams. The authors employed a double Gaussian function as the in-air fluence model of an individual beam. Double and triple Gaussian kernel models were also prepared for comparison. The parameters of the kernel lateral model were derived by fitting a simulated in-water lateral dose profile induced by an infinitesimal proton beam, whose emittance was zero, at various depths using Monte Carlo (MC) simulation. The fitted parameters were interpolated as a function of depth in water and stored as a separate look-up table. These stored parameters for each energy and depth in water were acquired from the look-up table when incorporating them into the TPS. The modeling process for the in-air fluence and IDD was based on the method proposed in the literature. These were derived using MC simulation and measured data. The authors compared the measured and calculated absolute doses at the center of the spread-out Bragg peak (SOBP) under various volumetric irradiation conditions to systematically investigate the influence of the two types of kernel models on the dose calculations. The authors investigated the difference

  15. Comparison of rectal volume definition techniques and their influence on rectal toxicity in patients with prostate cancer treated with 3D conformal radiotherapy: a dose-volume analysis

    International Nuclear Information System (INIS)

    Onal, Cem; Topkan, Erkan; Efe, Esma; Yavuz, Melek; Sonmez, Serhat; Yavuz, Aydin

    2009-01-01

    To evaluate the impact of four different rectum contouring techniques and rectal toxicities in patients with treated with 3D conformal radiotherapy (3DCRT). Clinical and dosimetric data were evaluated for 94 patients who received a total dose 3DCRT of 70 Gy, and rectal doses were compared in four different rectal contouring techniques: the prostate-containing CT sections (method 1); 1 cm above and below the planning target volume (PTV) (method 2); 110 mm starting from the anal verge (method 3); and from the anal verge to the sigmoid flexure (method 4). The percentage of rectal volume receiving RT doses (30–70 Gy) and minimum, mean rectal doses were assessed. Median age was 69 years. Percentage of rectal volume receiving high doses (≥ 70 Gy) were higher with the techniques that contoured smaller rectal volumes. In methods 2 and 3, the percentage of rectal volume receiving ≥ 70 Gy was significantly higher in patients with than without rectal bleeding (method 2: 30.8% vs. 22.5%, respectively (p = 0.03); method 3: 26.9% vs. 18.1%, respectively (p = 0.006)). Mean rectal dose was significant predictor of rectal bleeding only in method 3 (48.8 Gy in patients with bleeding vs. 44.4 Gy in patients without bleeding; p = 0.02). Different techniques of rectal contouring significantly influence the calculation of radiation doses to the rectum and the prediction of rectal toxicity. Rectal volume receiving higher doses (≥ 70 Gy) and mean rectal doses may significantly predict rectal bleeding for techniques contouring larger rectal volumes, as was in method 3

  16. Which genetic determinants should be considered for tacrolimus dose optimization in kidney transplantation?

    DEFF Research Database (Denmark)

    Bruckmueller, H; Werk, Anneke Nina; Renders, Lutz

    2014-01-01

    ). In addition, there are further polymorphic genes, possibly influencing CYP3A activity (pregnan x receptor NR1I2, P450 oxidoreductase POR and peroxisome proliferator-activator receptor alpha PPRA). We aimed to investigate combined effects of these gene variants on tacrolimus maintenance dose and PK in stable...

  17. The influence of ion energy, target temperature, dose rate and crystal order on the shape of bombardment induced pyramids on copper crystals

    International Nuclear Information System (INIS)

    Tanovic, L.; Whitton, J.L.; Kofod, S.

    1978-01-01

    Following recent studies of energetic ion bombardment of copper, which established the conditions necessary for the production of cones/pyramids, investigations have been extended to include the effects of change in ion energy, target temperature and dose rate. In addition, the authors have attempted a detailed analysis of the influence of sample crystal orientation on the final form of pyramids and have investigated the stability of the pyramids as a function of the total dose. These experiments, as in earlier work, have been done using very pure copper, mass-analyzed ion beams and free of any metal contamination from, for example, defining apertures. (Auth.)

  18. The influence of aspirin dose and glycemic control on platelet inhibition in patients with type 2 diabetes mellitus

    NARCIS (Netherlands)

    Lemkes, B. A.; Bahler, L.; Kamphuisen, P. W.; Stroobants, A. K.; van den Dool, E. J.; Hoekstra, J. B.; Nieuwland, R.; Gerdes, V. E.; Holleman, F.

    Background: Low-dose aspirin seems to offer no benefit in the primary prevention of cardiovascular disease in type 2 diabetes mellitus (DM2). The anti-platelet effect may be diminished by poor glycemic control or inadequate dosing of aspirin. Objectives: To study the effects of both glycemic control

  19. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  20. TPX remote maintenance and shielding

    International Nuclear Information System (INIS)

    Rennich, M.J.; Nelson, B.E.

    1994-01-01

    The Tokamak Physics Experiment machine design incorporates comprehensive planning for efficient and safe component maintenance. Three programmatic decisions have been made to insure the successful implementation of this objective. First, the tokamak incorporates radiation shielding to reduce activation of components and limit the dose rate to personnel working on the outside of the machine. This allows most of the ex-vessel equipment to be maintained through conventional ''hands-on'' procedures. Second, to the maximum extent possible, low activation materials will be used inside the shielding volume. This resulted in the selection of Titanium (Ti-6Al-4V) for the vacuum vessel and PFC structures. The third decision stipulated that the primary in-vessel components will be replaced or repaired via remote maintenance tools specifically provided for the task. The component designers have been given the responsibility of incorporating maintenance design and for proving the maintainability of the design concepts in full-scale mockup tests prior to the initiation of final fabrication. Remote maintenance of the TPX machine is facilitated by general purpose tools provided by a special purpose design team. Major tools will include an in-vessel transporter, a vessel transfer system and a large component transfer container. In addition, tools such as manipulators and remotely operable impact wrenches will be made available to the component designers by this group. Maintenance systems will also provide the necessary controls for this equipment

  1. A Situational Maintenance Model

    DEFF Research Database (Denmark)

    Luxhoj, James T.; Thorsteinsson, Uffe; Riis, Jens Ove

    1997-01-01

    An overview of trend in maintenance management and presentation of a situational model and an analytical tools for identification of managerial efforts in maintenance.......An overview of trend in maintenance management and presentation of a situational model and an analytical tools for identification of managerial efforts in maintenance....

  2. Collection of radiation resistant characteristics reports for instruments and materials in high dose rate environment

    International Nuclear Information System (INIS)

    Kusano, Joichi

    2008-03-01

    This document presents the collected official reports of radiation irradiation study for the candidate materials to be used in high dose rate environment as J-PARC facility. The effect of radiation damage by loss-beam or secondary particle beam of the accelerators influences the performance and the reliability of various instruments. The knowledge on the radiation resistivity of the materials is important to estimate the life of the equipments, the maintenance interval and dose evaluation for the personnel at the maintenance period. The radiation damage consists with mechanical property, electrical property and gas-evolution property. (author)

  3. Poster — Thur Eve — 33: The Influence of a Modeled Treatment Couch on Dose Distributions During IMRT and RapidArc Treatment Delivery

    International Nuclear Information System (INIS)

    Aldosary, Ghada; Nobah, Ahmad; Al-Zorkani, Faisal; Moftah, Belal; Devic, Slobodan

    2014-01-01

    Treatment couches have been known to perturb dose delivery in patients. This effect is most pronounced in techniques such as IMRT and RapidArc. Although modern treatment planning systems (TPS) include data for a “default” treatment couch, actual couches are not manufactured identically. Thus, variations in their Hounsfield Unit (HU) values may exist. This study demonstrates a practical and simple method of acquiring reliable HU data for any treatment couch. We also investigate the effects of both the default and modeled treatment couches on absorbed dose. Experimental verifications show that by neglecting to incorporate the treatment couch in the TPS, dose differences of up to 9.5% and 7.3% were present for 4 MV and 10 MV photon beams, respectively. Furthermore, a clinical study based on a cohort of 20 RapidArc and IMRT (brain, pelvis and abdominal) cases is performed. 2D dose distributions show that without the couch in the planning phase, differences ≤ 4.6% and 5.9% for RapidArc and IMRT cases are present for the same cases that the default couch was added to. Additionally, in comparison to the default couch, employing the modeled couch in the calculation process influences dose distributions by ≤ 2.7% and 8% for RapidArc and IMRT cases, respectively. This result was found to be site specific; where an accurate couch proves to be preferable for IMRT brain plans. As such, adding the couch during dose calculation decreases dose calculation errors, and a precisely modeled treatment couch offers higher dose delivery accuracy for brain treatment using IMRT

  4. Increasing doses of fiber do not influence short-term satiety or food intake and are inconsistently linked to gut hormone levels

    Directory of Open Access Journals (Sweden)

    Holly J. Willis

    2010-06-01

    Full Text Available Background: People who eat more fiber often have a lower body weight than people who eat less fiber. The mechanism for this relationship has been explained, in part, by increased satiety, which may occur as a result of changes in appetite-suppressing gut hormone levels, and decreases in food intake at subsequent meals. Objective: We hypothesized that increasing doses of mixed fiber, consumed in muffins for breakfast, would proportionally influence satiety, gut hormone levels, and subsequent food intake. Design: This was a randomized, double-blind, crossover study. Healthy men (n=10 and women (n=10 with a BMI of 24±2 (mean±SEM participated in this study. Fasting subjects consumed a muffin with 0, 4, 8, or 12 g of mixed fibers and approximately 500 kcal. Visual analog scales rated hunger and satiety for 3 h; blood was drawn to measure ghrelin, glucagon-like peptide-1 (GLP-1, and peptide YY3–36 (PYY3–36 at various intervals; and food intake was measured at an ad libitum lunch. Results: Responses to satiety-related questions did not differ among treatments. However, despite lack of differences in satiety, gut hormone levels differed among treatments. Ghrelin was higher after the 12 g fiber dose than after the 4 and 8 g fiber doses. GLP-1 was higher after the 0 g fiber dose than after the 12 and 4 g fiber doses, and PYY3–36 did not differ among fiber doses. Food intake was also indistinguishable among doses. Conclusion: Satiety, gut hormone response, and food intake did not change in a dose-dependent manner after subjects consumed 0, 4, 8, and 12 g of mixed fiber in muffins for breakfast.

  5. Poster — Thur Eve — 33: The Influence of a Modeled Treatment Couch on Dose Distributions During IMRT and RapidArc Treatment Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Aldosary, Ghada [Medical Physics Unit, Montreal General Hospital, McGill University, Montreal, Quebec (Canada); Nobah, Ahmad; Al-Zorkani, Faisal; Moftah, Belal [Biomedical Physics Department, King Faisal Specialist Hospital and Research Center, Riyadh (Saudi Arabia); Devic, Slobodan [Department of Radiation Oncology, Jewish General Hospital, McGill University, Montreal, Quebec (Canada)

    2014-08-15

    Treatment couches have been known to perturb dose delivery in patients. This effect is most pronounced in techniques such as IMRT and RapidArc. Although modern treatment planning systems (TPS) include data for a “default” treatment couch, actual couches are not manufactured identically. Thus, variations in their Hounsfield Unit (HU) values may exist. This study demonstrates a practical and simple method of acquiring reliable HU data for any treatment couch. We also investigate the effects of both the default and modeled treatment couches on absorbed dose. Experimental verifications show that by neglecting to incorporate the treatment couch in the TPS, dose differences of up to 9.5% and 7.3% were present for 4 MV and 10 MV photon beams, respectively. Furthermore, a clinical study based on a cohort of 20 RapidArc and IMRT (brain, pelvis and abdominal) cases is performed. 2D dose distributions show that without the couch in the planning phase, differences ≤ 4.6% and 5.9% for RapidArc and IMRT cases are present for the same cases that the default couch was added to. Additionally, in comparison to the default couch, employing the modeled couch in the calculation process influences dose distributions by ≤ 2.7% and 8% for RapidArc and IMRT cases, respectively. This result was found to be site specific; where an accurate couch proves to be preferable for IMRT brain plans. As such, adding the couch during dose calculation decreases dose calculation errors, and a precisely modeled treatment couch offers higher dose delivery accuracy for brain treatment using IMRT.

  6. Influence of radiation-dose pattern from inhaled beta--gamma-emitting radionuclides on canine peripheral lymphocytes

    International Nuclear Information System (INIS)

    Jones, R.K.; Boecker, B.B.; Pickrell, J.A.; Hobbs, C.H.; McClellan, R.O.

    1976-01-01

    As part of studies assess the biological hazards associated with inhaled radionuclides, periodic hematologic evaluations were performed on beagle dogs given a single nose-only exposure to aerosols of beta--gamma-emitting isotopes. The physical form and specific radionuclides selected produced radiation-dose patterns representative of those which might be encountered in the event of human accidental exposures. Dogs received graded lung burdens of either 90 Y, 91 Y, 144 Ce, or 90 Sr, each in fused clay. Differences in the effective half-lives of these radionuclides resulted in a spectrum of cumulative radiation doses to lung delivered at a variety of dose rates. Since the form in which the radionuclides were inhaled was relatively insoluble, the lung and intrathoracic tissues represented the primary recipient of the dose. Regardless of the effective half-life of radionuclide retention, a dose-related depression of peripheral lymphocytes was observed at various times after inhalation exposure. The time at which maximum depression and subsequent recovery occurred, however, was most directly related to the effective half-life of the radionuclide. Of special interest was the persistence of lymphopenia through 2 1 / 2 years after exposure to 144 Ce and 90 Sr in fused clay where, other than tracheobronchial lymph nodes, the lymphoid tissue received very little radiation dose. The possible mechanisms responsible for lymphocyte depression from these various radiation-dose patterns are discussed

  7. Influence of intravenous contrast agent on dose calculations of intensity modulated radiation therapy plans for head and neck cancer

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kim, Jeung-Kee; Lee, Hyung-Sik; Hur, Won-Joo; Hong, Young-Seoub; Park, Sungkwang; Ahn, Kijung; Cho, Heunglae

    2006-01-01

    Background and purpose: To evaluate the effect of an intravenous contrast agent (CA) on dose calculations and its clinical significance in intensity modulated radiation therapy (IMRT) plans for head and neck cancer. Materials and methods: Fifteen patients with head and neck cancer and involved neck nodes were enrolled. Each patient took two sets of computerized tomography (CT) in the same position before and after intravenous CA injections. Target volumes and organs at risk (OAR) were contoured on the enhanced CT, and then an IMRT plan of nine equiangular beams with a 6 MV X-ray was created. After the fusion of non-enhanced and enhanced CTs, the contours and the IMRT plan created from the enhanced CT were copied and placed to the non-enhanced CT. Doses were calculated again from the non-enhanced CT by the same IMRT plan. The radiation doses calculated from the two sets of CTs were compared with regard to planning target volumes (PTV) and the three OARs, both parotid glands and the spinal cord, by Wilcoxon's signed rank test. Results: The doses (maximum, mean, and the dose of 95% of PTV received (D 95% )) of PTV70 and PTV59.4 calculated from the enhanced CTs were lower than those from the non-enhanced CTs (p < 0.05), but the dose differences were less than 1% compared to the doses calculated from the enhanced CTs. The doses of PTV50.4, parotid glands, and spinal cord were not significantly different between the non-enhanced and enhanced CTs. Conclusions: The difference between the doses calculated from the CTs with and without CA enhancement was tolerably small, therefore using intravenous CA could be recommended for the planning CT of head and neck IMRT

  8. The influence of the ion implantation temperature and the dose rate on smart-cut in GaAs

    International Nuclear Information System (INIS)

    Webb, M.; Jeynes, C.; Gwilliam, R.; Too, P.; Kozanecki, A.; Domagala, J.; Royle, A.; Sealy, B.

    2005-01-01

    The temperature and dose rate dependence of the smart-cut process in GaAs have been investigated in this paper. The distribution of hydrogen and the implantation damage in the samples were studied by ion beam analysis and X-ray diffraction. It was found that at higher temperatures, hydrogen is mobile in the lattice and can rearrange into the platelets, microcracks and bubbles which are present in blistered material, thus relieving the strain in the lattice. The dose rate was also found to be significant for the smart-cut process, as blistering and exfoliation are inhibited at low dose rates

  9. The study of influence of relevant physical parameters variations on the estimates of the effective doses of Rn-222

    International Nuclear Information System (INIS)

    Ridzikova, A.; Fronka, A.; Moucka, L.

    2004-01-01

    Based on the analysis of 12 weekly continuous measurements and 4 integral measurements performed in different seasons in actual apartment rooms, bedrooms in particular, we attempted to identify the uncertainties that are involved in the estimation of radiation doses to lung tissues. We found that the parameters of time of residence, concentration, and equilibrium factor can affect substantially the estimate of the overall early effective dose. The weekly averaged concentration measured in one term is not sufficient for a fairly accurate estimate; actually, the equilibrium factor f must also be known and the actual real individual time of residence must be estimated if we want to adopt this approach to the dose estimation

  10. Preventive maintenance and reliability-centered maintenance

    International Nuclear Information System (INIS)

    Anderson, J.G.

    1989-01-01

    In the recent past, the primary function of the preventive maintenance program at a nuclear power plant was to maintain the operability and reliability of the plant. Reducing overall maintenance costs by performing effective preventive maintenance, instead of more costly and disruptive corrective maintenance, instead of more costly and disruptive corrective maintenance, was a secondary consideration. In today's operating environment, the preventive maintenance program must meet the test of cost-effectiveness as well as many new standards for performance that are being required by rate regulators. The preventive maintenance program must be able to withstand the challenge of independent audit to a new standard of technical adequacy and compliance with recommendations from component vendors. In this new environment, the standard that is being applied at the San Onofre nuclear generating station (SONGS) is that the preventive maintenance program must meet the test of cost-effectiveness, improve equipment performance, support increased plant availability, and (a) literally implement the recommendations of the vendor, (b) provide other compensation for the vendor recommendation, or (c) provide technical justification for the deviation. The subject of this paper is the way that reliability-centered maintenance (RCM) is helping SONGS meet these challenges

  11. The influence of tube voltage and phantom size in computed tomography on the dose-response relationship of dicentrics in human blood samples

    International Nuclear Information System (INIS)

    Jost, G; Pietsch, H; Lengsfeld, P; Voth, M; Schmid, E

    2010-01-01

    The aim of this study was to investigate the dose response relationship of dicentrics in human lymphocytes after CT scans at tube voltages of 80 and 140 kV. Blood samples from a healthy donor placed in tissue equivalent abdomen phantoms of standard, pediatric and adipose sizes were exposed at dose levels up to 0.1 Gy using a 64-slice CT scanner. It was found that both the tube voltage and the phantom size significantly influenced the CT scan-induced linear dose-response relationship of dicentrics in human lymphocytes. Using the same phantom (standard abdomen), 80 kV CT x-rays were biologically more effective than 140 kV CT x-rays. However, it could also be determined that the applied phantom size had much more influence on the biological effectiveness. Obviously, the increasing slopes of the CT scan-induced dose response relationships of dicentrics in human lymphocytes obtained in a pediatric, a standard and an adipose abdomen have been induced by scattering effects of photons, which strongly increase with increasing phantom size.

  12. The influence of tube voltage and phantom size in computed tomography on the dose-response relationship of dicentrics in human blood samples

    Energy Technology Data Exchange (ETDEWEB)

    Jost, G; Pietsch, H [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, P; Voth, M [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Schmid, E, E-mail: Ernst.Schmid@lrz.uni-muenchen.d [Institute for Cell Biology, Center for Integrated Protein Science, University of Munich (Germany)

    2010-06-07

    The aim of this study was to investigate the dose response relationship of dicentrics in human lymphocytes after CT scans at tube voltages of 80 and 140 kV. Blood samples from a healthy donor placed in tissue equivalent abdomen phantoms of standard, pediatric and adipose sizes were exposed at dose levels up to 0.1 Gy using a 64-slice CT scanner. It was found that both the tube voltage and the phantom size significantly influenced the CT scan-induced linear dose-response relationship of dicentrics in human lymphocytes. Using the same phantom (standard abdomen), 80 kV CT x-rays were biologically more effective than 140 kV CT x-rays. However, it could also be determined that the applied phantom size had much more influence on the biological effectiveness. Obviously, the increasing slopes of the CT scan-induced dose response relationships of dicentrics in human lymphocytes obtained in a pediatric, a standard and an adipose abdomen have been induced by scattering effects of photons, which strongly increase with increasing phantom size.

  13. Study of the influence of gold particles on the absorbed dose in soft tissue using polymer gel dosimetry

    International Nuclear Information System (INIS)

    Afonso, Luciana Caminha

    2011-01-01

    The presence of high-Z material adjacent to soft tissue, when submitted to irradiation, enhances locally the absorbed dose in these soft tissues. Such effect occurs due to the outscattering of photoelectrons from the high-Z material. Polymer gel dosimeters have been used to investigate this effect. Analytic calculations to estimate the dose enhancement and Monte Carlo simulations have been performed. Samples containing polymer gel (PG) with 0.005 gAu/gPG and pure polymer gel have been irradiated using an X-rays beam produced by 150 kV, filtered with 4 mm Al and 5 mm Cu, which resulted in an approximately 20% higher absorbed dose in the samples with gold in comparison to those with pure polymer gel. The analytic calculations and the Monte Carlo simulation resulted in a dose enhancement factor of approximately 30%. (author)

  14. Influence of Ultra-Low-Dose and Iterative Reconstructions on the Visualization of Orbital Soft Tissues on Maxillofacial CT.

    Science.gov (United States)

    Widmann, G; Juranek, D; Waldenberger, F; Schullian, P; Dennhardt, A; Hoermann, R; Steurer, M; Gassner, E-M; Puelacher, W

    2017-08-01

    Dose reduction on CT scans for surgical planning and postoperative evaluation of midface and orbital fractures is an important concern. The purpose of this study was to evaluate the variability of various low-dose and iterative reconstruction techniques on the visualization of orbital soft tissues. Contrast-to-noise ratios of the optic nerve and inferior rectus muscle and subjective scores of a human cadaver were calculated from CT with a reference dose protocol (CT dose index volume = 36.69 mGy) and a subsequent series of low-dose protocols (LDPs I-4: CT dose index volume = 4.18, 2.64, 0.99, and 0.53 mGy) with filtered back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR)-50, ASIR-100, and model-based iterative reconstruction. The Dunn Multiple Comparison Test was used to compare each combination of protocols (α = .05). Compared with the reference dose protocol with FBP, the following statistically significant differences in contrast-to-noise ratios were shown (all, P ≤ .012) for the following: 1) optic nerve: LDP-I with FBP; LDP-II with FBP and ASIR-50; LDP-III with FBP, ASIR-50, and ASIR-100; and LDP-IV with FBP, ASIR-50, and ASIR-100; and 2) inferior rectus muscle: LDP-II with FBP, LDP-III with FBP and ASIR-50, and LDP-IV with FBP, ASIR-50, and ASIR-100. Model-based iterative reconstruction showed the best contrast-to-noise ratio in all images and provided similar subjective scores for LDP-II. ASIR-50 had no remarkable effect, and ASIR-100, a small effect on subjective scores. Compared with a reference dose protocol with FBP, model-based iterative reconstruction may show similar diagnostic visibility of orbital soft tissues at a CT dose index volume of 2.64 mGy. Low-dose technology and iterative reconstruction technology may redefine current reference dose levels in maxillofacial CT. © 2017 by American Journal of Neuroradiology.

  15. Adaptive evolution influences the infectious dose of MERS-CoV necessary to achieve severe respiratory disease.

    Science.gov (United States)

    Douglas, Madeline G; Kocher, Jacob F; Scobey, Trevor; Baric, Ralph S; Cockrell, Adam S

    2018-04-01

    We recently established a mouse model (288-330 +/+ ) that developed acute respiratory disease resembling human pathology following infection with a high dose (5 × 10 6 PFU) of mouse-adapted MERS-CoV (icMERSma1). Although this high dose conferred fatal respiratory disease in mice, achieving similar pathology at lower viral doses may more closely reflect naturally acquired infections. Through continued adaptive evolution of icMERSma1 we generated a novel mouse-adapted MERS-CoV (maM35c4) capable of achieving severe respiratory disease at doses between 10 3 and 10 5 PFU. Novel mutations were identified in the maM35c4 genome that may be responsible for eliciting etiologies of acute respiratory distress syndrome at 10-1000 fold lower viral doses. Importantly, comparative genetics of the two mouse-adapted MERS strains allowed us to identify specific mutations that remained fixed through an additional 20 cycles of adaptive evolution. Our data indicate that the extent of MERS-CoV adaptation determines the minimal infectious dose required to achieve severe respiratory disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Evaluation of ambient dose equivalent rates influenced by vertical and horizontal distribution of radioactive cesium in soil in Fukushima Prefecture.

    Science.gov (United States)

    Malins, Alex; Kurikami, Hiroshi; Nakama, Shigeo; Saito, Tatsuo; Okumura, Masahiko; Machida, Masahiko; Kitamura, Akihiro

    2016-01-01

    The air dose rate in an environment contaminated with (134)Cs and (137)Cs depends on the amount, depth profile and horizontal distribution of these contaminants within the ground. This paper introduces and verifies a tool that models these variables and calculates ambient dose equivalent rates at 1 m above the ground. Good correlation is found between predicted dose rates and dose rates measured with survey meters in Fukushima Prefecture in areas contaminated with radiocesium from the Fukushima Dai-ichi Nuclear Power Plant accident. This finding is insensitive to the choice for modeling the activity depth distribution in the ground using activity measurements of collected soil layers, or by using exponential and hyperbolic secant fits to the measurement data. Better predictions are obtained by modeling the horizontal distribution of radioactive cesium across an area if multiple soil samples are available, as opposed to assuming a spatially homogeneous contamination distribution. Reductions seen in air dose rates above flat, undisturbed fields in Fukushima Prefecture are consistent with decrement by radioactive decay and downward migration of cesium into soil. Analysis of remediation strategies for farmland soils confirmed that topsoil removal and interchanging a topsoil layer with a subsoil layer result in similar reductions in the air dose rate. These two strategies are more effective than reverse tillage to invert and mix the topsoil. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. CT for evaluation of potential renal donors – How does iterative reconstruction influence image quality and dose?

    Energy Technology Data Exchange (ETDEWEB)

    Kahn, Johannes, E-mail: johannes.kahn@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Grupp, Ulrich, E-mail: ulrich.grupp@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Rotzinger, Roman, E-mail: roman.rotzinger@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Kaul, David, E-mail: david.kaul@charite.de [Department of Radiooncology and Radiotherapy, Charité, Charitéplatz 1, 10117 Berlin (Germany); Schäfer, Max-Ludwig, E-mail: max-ludwig.schaefer@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Streitparth, Florian, E-mail: florian.streitparth@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany)

    2014-08-15

    Purpose: To assess ASIR (adaptive statistical iterative reconstruction) technique regarding dose reduction and its impact on image quality in evaluation CTs of potential kidney donors. Materials and methods: Between May and November 2013, a prospective study of 53 assumingly healthy potential kidney donors was conducted. The subjects underwent abdominal evaluation CT prior to the planned explantation of a kidney and were randomly divided into 2 groups: Group A was examined with an ASIR 40 protocol (n = 26), group B (n = 27) was examined using a standard FBP (filtered back projection) protocol. Image quality was assessed both quantitatively (by obtaining attenuation values in different organ regions and calculating SNR and CNRs) and qualitatively (by two observers who evaluated image quality using a 5-point scale system). Applied dose was analyzed as CTDIvol (mGy), total DLP (mGy × cm) and effective dose (mSv). Results: Applied dose in group A was about 26% lower than in group B (p < 0.05). Between both groups, dose determining parameters such as scan length and patients’ body diameter showed no significant difference. SNR (signal-to-noise ratio) was significantly higher in group A (p < 0.05). CNRs (contrast-to-noise ratios) for different tissues were not significantly different. Observer rated image quality showed no significant difference. Conclusion: ASIR can contribute to a relevant dose reduction without any loss of image quality in CT scans for evaluating potential kidney donors.

  18. Methotrexate/6-mercaptopurine maintenance therapy influences the risk of a second malignant neoplasm after childhood acute lymphoblastic leukemia: results from the NOPHO ALL-92 study

    DEFF Research Database (Denmark)

    Schmiegelow, Kjeld; Al-Modhwahi, Ibrahim; Andersen, Mette Klarskov

    2009-01-01

    Among 1614 children with acute lymphoblastic leukemia (ALL) treated with the Nordic Society for Paediatric Haematology and Oncology (NOPHO) ALL-92 protocol, 20 patients developed a second malignant neoplasm (SMN) with a cumulative risk of 1.6% at 12 years from the diagnosis of ALL. Nine of the 16...... acute myeloid leukemias or myelodysplastic syndromes had monosomy 7 (n = 7) or 7q deletions (n = 2). In Cox multivariate analysis, longer duration of oral 6-mercaptopurine (6MP)/methotrexate (MTX) maintenance therapy (P = .02; longest for standard-risk patients) and presence of high hyperdiploidy (P...

  19. Fluxo difusivo de fósforo em função de doses e da umidade do solo Influence of phosphorus doses and soil moisture on diffusion flow

    Directory of Open Access Journals (Sweden)

    José P. V. da Costa

    2006-12-01

    Full Text Available A difusão é o mecanismo mais expressivo do transporte do fósforo no solo e depende de vários fatores, como o conteúdo volumétrico de água, a interação fósforo-colóide do solo, a distância da fonte às raízes, o teor e a temperatura do solo. Avaliaram-se os efeitos do conteúdo volumétrico de água e de doses de fósforo no seu fluxo difusivo no solo, em amostras da camada superficial de cinco solos. O experimento consistiu do arranjo fatorial 5 x 8 x 5, referente a cinco materiais de solo, oito níveis de umidade e cinco doses de fósforo, dispostos em blocos ao acaso, com quatro repetições. Como unidade experimental foram utilizados anéis de PVC com volume útil de 360 cm³, que serviram como câmara de difusão. Para avaliação do fluxo difusivo de fósforo nas amostras foram utilizadas lâminas de resina de troca aniônica (IONICS 204UZRA. Pelos resultados, constatou-se que o fluxo difusivo sofre influência da umidade do solo e das doses de fósforo aplicadas.The main phosphorus transport mechanism in the soil is diffusion, which is influenced by several soil factors, such as volumetric water content, phosphorus-colloid interaction, distance between source and roots, content and temperature. The effects of the soil water content and phosphorus doses on the diffusion flow into soil were assessed in samples from the superficial layers of five soils. The treatments were arranged in a 5 x 8 x 5 factorial design corresponding, respectively, to five soils, eight moisture levels and five phosphorus doses. A completely randomized block design with four replications was used. The experimental unit was a PVC ring with a volume of 360 cm³, which acted as a diffusion chamber. Anionic exchange resin slides (IONICS 204UZRA were utilized to assess the phosphorus diffusion flow. Results indicated that the diffusion flow was influenced by phosphorus doses and moisture content.

  20. The influence of non-radiation induced ESR background signal from paraffin-alanine probes for dosimetry in the radiotherapy dose range

    International Nuclear Information System (INIS)

    Wieser, A.; Lettau, C.; Fill, U.; Regulla, D.F.

    1993-01-01

    The yield of radicals induced by ionizing radiation in the amino acid alanine and its quantification by ESR spectroscopy has proven excellent reproducibility. Those radicals trapped in the crystal lattice are prevented from recombination providing a thermally very stable system. This allows alanine to be applied as a transfer dosemeter. With paraffin-alanine probes ESR dosimetry can be performed with a standard deviation of ± 0.5% in the dose range from 20 Gy up to 100 kGy. At 1 Gy dose level the error increases to ± 6%. This dose level is three orders of magnitude higher than the calculated detection threshold for alanine with modern X-band ESR spectrometers. It was found that the poor standard deviation at the 1 Gy dose level, is not mainly produced by a bad signal-to-noise ratio but by a variable non-radiation induced ESR background signal from the alanine probes within a batch. In the present study the main sources of error for ESR dosimetry in the dose range below 20 Gy were analyzed. The influences of the production process, UV light and humidity upon the ESR background signal from paraffin-alanine probes were investigated. Measurements are shown indicating a second stable structure of the alanine radical at room temperature. (author)

  1. Advanced maintenance research programs

    International Nuclear Information System (INIS)

    Marston, T.U.; Gelhaus, F.; Burke, R.

    1985-01-01

    The purpose of this paper is to provide the reader with an idea of the advanced maintenance research program at the Electric Power Research Institute (EPRI). A brief description of the maintenance-related activities is provided as a foundation for the advanced maintenance research projects. The projects can be divided into maintenance planning, preventive maintenance program development and implementation, predictive (or conditional) maintenance, and innovative maintenance techniques. The projects include hardware and software development, human factors considerations, and technology promotion and implementation. The advanced concepts include: the incorporation of artificial intelligence into outage planning; turbine and pump maintenance; rotating equipment monitoring and diagnostics with the aid of expert systems; and the development of mobile robots for nuclear power plant maintenance

  2. Radiation-induced rectal complications are not influenced by age: a dose fractionation study in the rat.

    Science.gov (United States)

    van den Aardweg, Gerard J M J; Olofsen-van Acht, Manouk J J; van Hooije, Christel M C; Levendag, Peter C

    2003-05-01

    Radiation-induced complications of the rectum are an important dose-limiting factor in radiotherapy of pelvic malignancies. In general, animal studies demonstrated no differences in acute and late normal tissue toxicity with age, but little is known about rectal complications in relation to age. For this purpose, an extensive histological and dose fractionation study was carried out on the rectum of young (12 weeks) and older (77-80 weeks) rats. In this paper, the results of dose fractionation are presented in relation to age at the time of irradiation. Young and older animals were irradiated with single and fractionated doses. After irradiation, rectal complications could lead to occlusion and stenosis, eventually resulting in the clinical symptoms of a megacolon and a possible fistula. For each dose group, cumulative survival rates were obtained with Kaplan-Meier analysis, from which dose-effect curves and the associated LD(50) values for a megacolon/fistula were calculated. The majority of responders died between 8 and 24 weeks after irradiation, irrespective of age. For both age groups, only the fractionation data showed a reduction in the mean latency with increasing dose. In the older age group, 39% of the responders developed a fistula compared to 26% for the younger animals. The LD(50) values increased from around 30 Gy after single doses to nearly 65 Gy after 10 fractions. The increases in LD(50) values with the number of fractions were independent of the age of the rats. For each of the dose fractionation schedules, log-rank testing indicated no significant differences in cumulative survival rates between younger and older animals (P > 0.10). The high alpha/beta ratios obtained for both the young and older animals strongly suggested that the late rectal complications were a consequence of early epithelial injury. Associated histological findings indicated that blood vessel damage, which was already evident at a high incidence at 4 weeks after irradiation

  3. Male gonadal dose an adjuvant 3-D-pelvic irradiation after anterior resection of rectal cancer. Influence to fertility

    International Nuclear Information System (INIS)

    Piroth, M.D.; Hensley, F.; Wannenmacher, M.; Zierhut, D.

    2003-01-01

    Background: Rectal cancer is a common malignant disease and occurs not infrequently in younger men. We verified the dose to the testes from scattered radiation in adjuvant pelvic irradiation following anterior resection of rectal cancer. Patients and Method: We measured the scattered gonadal dose of 18 patients in vivo with thermoluminescence detectors, which were fixed on four defined points on the scrotum during radiation on three consecutive days. All patients were treated three-dimensionally planned using a three-field box lying in prone position in a bellyboard. A total dose of 50.4 Gy was given in 28 fractions of 1.8 Gy. From 45 up to 50.4 Gy the radiation fields were modified to lateral-opposing fields which were shortened from the top to protect the small bowel. Results: The mean gonadal dose per fraction of all patients was 0.057 Gy (median 0.05 Gy) with a range between 0.035 and 0.114 Gy. The standard deviation was 0.02 Gy. The calculated cumulative mean gonadal dose after 28 fractions was 1.60 Gy (0.98-3.19 Gy). Conclusions: Germinal epithelium is very sensitive to low-dose irradiation, according to a negative fractionation effect. It is known that gonadal total doses of 1 Gy with single doses of 0.03-0.05 Gy can result in a temporary azoospermia with following recovery in most cases. If gonadal total doses exceed 1.5 Gy a substantial increase in irreversible azoospermia must be expected. With respect to the data reported in the literature our measured mean gonadal total dose of 1.60 Gy will lead with high probability to an irreversible infertility. Because of the small number of patients in our study, the data must be interpreted with caution, however, it is very important in patient's informed consent to draw attention to the high risk of infertility. The possibility of sperm cryoconservation should be discussed with the patient. (orig.) [de

  4. Maintenance considerations of the Starfire Commercial Tokamak

    International Nuclear Information System (INIS)

    Trachael, C.A.; Zahn, H.S.; Field, R.E.; Stevens, H.C.

    1979-01-01

    An initial reactor design has been developed for the Starfire Tokamak reactor that incorporates maintenance features to permit reactor and plant operation with a 75% availability. All components of the reactor can be replaced utilizing highly automated remote maintenance techniques. Provisions for contact maintenance are included but would only be utilized on a contingency basis since it is believed that allowable dose rates will be decreased in future years. A modular design approach is used for the reactor and auxiliary subsystems to permit efficient use of remote maintenance. The modular approach minimizes the number of different maintenance operations required and can result in use of simple tasks such as push, pull, turn, etc., maneuvers for module removal. Fault isolation is provided for each replaceable module

  5. Managing anthelmintic resistance-Variability in the dose of drug reaching the target worms influences selection for resistance?

    Science.gov (United States)

    Leathwick, Dave M; Luo, Dongwen

    2017-08-30

    The concentration profile of anthelmintic reaching the target worms in the host can vary between animals even when administered doses are tailored to individual liveweight at the manufacturer's recommended rate. Factors contributing to variation in drug concentration include weather, breed of animal, formulation and the route by which drugs are administered. The implications of this variability for the development of anthelmintic resistance was investigated using Monte-Carlo simulation. A model framework was established where 100 animals each received a single drug treatment. The 'dose' of drug allocated to each animal (i.e. the concentration-time profile of drug reaching the target worms) was sampled at random from a distribution of doses with mean m and standard deviation s. For each animal the dose of drug was used in conjunction with pre-determined dose-response relationships, representing single and poly-genetic inheritance, to calculate efficacy against susceptible and resistant genotypes. These data were then used to calculate the overall change in resistance gene frequency for the worm population as a result of the treatment. Values for m and s were varied to reflect differences in both mean dose and the variability in dose, and for each combination of these 100,000 simulations were run. The resistance gene frequency in the population after treatment increased as m decreased and as s increased. This occurred for both single and poly-gene models and for different levels of dominance (survival under treatment) of the heterozygote genotype(s). The results indicate that factors which result in lower and/or more variable concentrations of active reaching the target worms are more likely to select for resistance. The potential of different routes of anthelmintic administration to play a role in the development of anthelmintic resistance is discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Influence of NR3C1 and VDR polymorphisms on stable warfarin dose in patients with mechanical cardiac valves.

    Science.gov (United States)

    Lee, Kyung Eun; Chung, Jee Eun; Yi, Boram; Cho, Yoon Jeong; Kim, Hyun Jeong; Lee, Gwan Yung; Kim, Joo Hee; Chang, Byung Chul; Gwak, Hye Sun

    2017-06-01

    The aim of this study was to evaluate the associations between polymorphisms of VKORC1, CYP2C9, CYP4F2, NR3C1 and VDR genes and stable warfarin doses in Korean patients with mechanical heart valves. Seventeen single-nucleotide polymorphisms (SNPs) in 204 patients with stable warfarin dose were analyzed: VKORC1 (rs9934438), CYP2C9 (rs1057910), CYP4F2 (rs2108622), NR3C1 (rs41423247, rs1800445, rs56149945, rs10052957, rs6198, rs33388, rs6196, and rs244465), and VDR (rs1544410, rs11568820, rs731236, rs757343, rs7975232, and rs2228570). Statistical analyses were conducted to evaluate the associations of gene variations with stable warfarin dose. Number needed to genotype was obtained by calculating the percentage of patients whose predicted dose was at least 20% higher or lower than the actual stable dose. The combined genotypes of rs7975232 and rs2228570 of the VDR gene revealed a significant association with stable warfarin dose, along with VKORC1, CYP2C9, and CYP4F2 polymorphisms. Patients with the genotype combination GT,TT/CT,CC of VDR rs7975232/rs2228570 required significantly higher stable warfarin dose (5.79±2.02mg) than those with the other genotypic combinations (5.19±1.78mg, p=0.034). Multivariate analysis showed that VDR rs7975232/rs2228570 explained 2.0% of the 47.5% variability in overall warfarin dose. Adding VDR SNP combinations to the base model including non-genetic variables (age, sex, and body weight) and genetic variables (VKORC1 rs9934438, CYP2C9 rs1057910, and CYP4F2 rs2108622) gave a number needed to genotype of 41. This study showed that stable warfarin dose is associated with VDR SNPs along with VKORC1, CYP2C9, and CYP4F2 SNPs. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Influence of low dose {gamma} radiation on the dormancy, growth and physiological activity of seed potato (solanum tuberosum L.)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Lee, Y. K.; Lee, H. Y.; Baek, M. H.; Yoo, Z. C. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    To observe the stimulating effect of low dose {gamma} radiation on the dormancy breaking and growth of potato with different storage duration and conditions, potato were irradiated with the dose of 1 {approx} 16 Gy. Though varied with storage duration and conditions, sprouting rate of potato stored at 5 .deg. C in the dark was promoted at the 8 and 16 Gy irradiation group compared to 20 .deg. C in the light. The field growth of potato stored at 5 .deg. C in the dark was highly increased at the 2, 4, 8 Gy irradiation group. The CAT activity of potato was increased by about 20% at 1,8 and 16 Gy irradiation group. POD activity was also increased by 7 {approx} 16% at 1, 8 and 16 Gy irradiation group compared to the control. Fv/Fm was not changed by the low dose {gamma} radiation. However, the effective quantum yield of PSII was slightly increased by about 12% at 1 and 16 Gy irradiation group. Seedling irradiated with low dose {gamma} radiation showed the lower excitation pressure on PSII (1- {sub q}P), while NPQ was greatly increased by 45% at 4 Gy irradiation group. These results clearly showed the positive effect of low dose {gamma} radiation on the seedling growth of potato via increasing photoprotective capacities of photosynthetic apparatus.

  8. Influence of bismuth shielding use in the dose CT and the imaging quality in standard brain protocol

    International Nuclear Information System (INIS)

    Sanchez Carnoma, G.; Urena Llinares, A.; Santos Rubio, A.; Haro Madero, G.; Herrador Cordoba, M.

    2006-01-01

    The purpose of this work is to evaluate the reduction of lens doses, CT dose index (CTDI) and image quality when bismuth shielding is used. Dose indexes nCDTIs,p, w were measured for a head phantom (d=16 cm) in three situations: first, without shielding, second, shielded with bismuth over the phantom surface and, last, with 2 cm between both. Four regions of interest were selected, two including the theoretical eyes position and the others 4-6 cm below them. Noise and grey level in Housfield units were also measured in all geometries. A bismuth shielding in contact or 2 cm above surface provides a dose reduction of 36% y 29% respectively. In the first case an importation of image quality appears, increasing a 55% the Housfield units in the superficial regions of interest and a growth of noise 6 times greater. Bismuth protection provides an important reduction in lens dose., in the case of dire ct incidence radiation beam. (Author)

  9. Influence of low dose γ radiation on the dormancy, growth and physiological activity of seed potato (solanum tuberosum L.)

    International Nuclear Information System (INIS)

    Kim, J. S.; Lee, Y. K.; Lee, H. Y.; Baek, M. H.; Yoo, Z. C.

    2002-01-01

    To observe the stimulating effect of low dose γ radiation on the dormancy breaking and growth of potato with different storage duration and conditions, potato were irradiated with the dose of 1 ∼ 16 Gy. Though varied with storage duration and conditions, sprouting rate of potato stored at 5 .deg. C in the dark was promoted at the 8 and 16 Gy irradiation group compared to 20 .deg. C in the light. The field growth of potato stored at 5 .deg. C in the dark was highly increased at the 2, 4, 8 Gy irradiation group. The CAT activity of potato was increased by about 20% at 1,8 and 16 Gy irradiation group. POD activity was also increased by 7 ∼ 16% at 1, 8 and 16 Gy irradiation group compared to the control. Fv/Fm was not changed by the low dose γ radiation. However, the effective quantum yield of PSII was slightly increased by about 12% at 1 and 16 Gy irradiation group. Seedling irradiated with low dose γ radiation showed the lower excitation pressure on PSII (1- q P), while NPQ was greatly increased by 45% at 4 Gy irradiation group. These results clearly showed the positive effect of low dose γ radiation on the seedling growth of potato via increasing photoprotective capacities of photosynthetic apparatus

  10. Influence of the Extent and Dose of Radiation on Complications After Neoadjuvant Chemoradiation and Subsequent Esophagectomy With Gastric Tube Reconstruction With a Cervical Anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Koëter, M.; Kathiravetpillai, N. [Department of Surgery, Catharina Hospital Eindhoven, Eindhoven (Netherlands); Gooszen, J.A.; Berge Henegouwen, M.I. van; Gisbertz, S.S. [Department of Surgery, Academic Medical Centre Amsterdam, Amsterdam (Netherlands); Sangen, M.J.C. van der [Department of Radiation Oncology, Catharina Hospital Eindhoven, Eindhoven (Netherlands); Luyer, M.D.P. [Department of Surgery, Catharina Hospital Eindhoven, Eindhoven (Netherlands); Nieuwenhuijzen, G.A.P., E-mail: grard.nieuwenhuijzen@catharinaziekenhuis.nl [Department of Surgery, Catharina Hospital Eindhoven, Eindhoven (Netherlands); Hulshof, M.C.C.M. [Department of Radiation Oncology, Academic Medical Centre Amsterdam, Amsterdam (Netherlands)

    2017-03-15

    Purpose: To determine, in a large series, the influence of the extent and dose of radiation to the fundus of the stomach and mediastinum on the development and severity of anastomotic complications in patients with esophageal cancer treated with neoadjuvant chemoradiation followed by esophagectomy with cervical anastomosis. Methods and Materials: Between 2005 and 2012, 364 consecutive patients with esophageal cancer treated with neoadjuvant chemoradiation (41.4 Gy combined with chemotherapy) followed by esophagectomy were included. The future anastomotic region in the fundus was determined, and the mean dose, V20-V40, and upper planning target volume border in relation to mediastinal length, expressed as the mediastinal ratio, were calculated. Results: Anastomotic leakage occurred in 22% and anastomotic stenosis in 41%. Logistic regression analysis revealed no influence of age, comorbidity, mean fundus dose, V20-V40, or the mediastinal ratio on the incidence of anastomotic leakage or anastomotic stenosis. In 28% of the patients severe complications (Clavien-Dindo score of ≥IIIB) occurred. The presence of multiple comorbidities (hazard ratio 2.4 [95% confidence interval 1.3-4.5], P=.006) and a mediastinal ratio of 0.5 to 1.0 (hazard ratio 1.9 [95% confidence interval 1.0-3.5], P=.036) were both independent predictors of severe complications. Conclusion: With a mean radiation dose of 24.2 Gy to the future anastomotic region of the gastric fundus, the radiation dose was not associated with the incidence of anastomotic leakage or anastomotic stenosis. The incidence of severe complications was associated with a high superior mediastinal planning target volume border.

  11. Influence of the Extent and Dose of Radiation on Complications After Neoadjuvant Chemoradiation and Subsequent Esophagectomy With Gastric Tube Reconstruction With a Cervical Anastomosis

    International Nuclear Information System (INIS)

    Koëter, M.; Kathiravetpillai, N.; Gooszen, J.A.; Berge Henegouwen, M.I. van; Gisbertz, S.S.; Sangen, M.J.C. van der; Luyer, M.D.P.; Nieuwenhuijzen, G.A.P.; Hulshof, M.C.C.M.

    2017-01-01

    Purpose: To determine, in a large series, the influence of the extent and dose of radiation to the fundus of the stomach and mediastinum on the development and severity of anastomotic complications in patients with esophageal cancer treated with neoadjuvant chemoradiation followed by esophagectomy with cervical anastomosis. Methods and Materials: Between 2005 and 2012, 364 consecutive patients with esophageal cancer treated with neoadjuvant chemoradiation (41.4 Gy combined with chemotherapy) followed by esophagectomy were included. The future anastomotic region in the fundus was determined, and the mean dose, V20-V40, and upper planning target volume border in relation to mediastinal length, expressed as the mediastinal ratio, were calculated. Results: Anastomotic leakage occurred in 22% and anastomotic stenosis in 41%. Logistic regression analysis revealed no influence of age, comorbidity, mean fundus dose, V20-V40, or the mediastinal ratio on the incidence of anastomotic leakage or anastomotic stenosis. In 28% of the patients severe complications (Clavien-Dindo score of ≥IIIB) occurred. The presence of multiple comorbidities (hazard ratio 2.4 [95% confidence interval 1.3-4.5], P=.006) and a mediastinal ratio of 0.5 to 1.0 (hazard ratio 1.9 [95% confidence interval 1.0-3.5], P=.036) were both independent predictors of severe complications. Conclusion: With a mean radiation dose of 24.2 Gy to the future anastomotic region of the gastric fundus, the radiation dose was not associated with the incidence of anastomotic leakage or anastomotic stenosis. The incidence of severe complications was associated with a high superior mediastinal planning target volume border.

  12. Influence of the Extent and Dose of Radiation on Complications After Neoadjuvant Chemoradiation and Subsequent Esophagectomy With Gastric Tube Reconstruction With a Cervical Anastomosis.

    Science.gov (United States)

    Koëter, M; Kathiravetpillai, N; Gooszen, J A; van Berge Henegouwen, M I; Gisbertz, S S; van der Sangen, M J C; Luyer, M D P; Nieuwenhuijzen, G A P; Hulshof, M C C M

    2017-03-15

    To determine, in a large series, the influence of the extent and dose of radiation to the fundus of the stomach and mediastinum on the development and severity of anastomotic complications in patients with esophageal cancer treated with neoadjuvant chemoradiation followed by esophagectomy with cervical anastomosis. Between 2005 and 2012, 364 consecutive patients with esophageal cancer treated with neoadjuvant chemoradiation (41.4 Gy combined with chemotherapy) followed by esophagectomy were included. The future anastomotic region in the fundus was determined, and the mean dose, V20-V40, and upper planning target volume border in relation to mediastinal length, expressed as the mediastinal ratio, were calculated. Anastomotic leakage occurred in 22% and anastomotic stenosis in 41%. Logistic regression analysis revealed no influence of age, comorbidity, mean fundus dose, V20-V40, or the mediastinal ratio on the incidence of anastomotic leakage or anastomotic stenosis. In 28% of the patients severe complications (Clavien-Dindo score of ≥IIIB) occurred. The presence of multiple comorbidities (hazard ratio 2.4 [95% confidence interval 1.3-4.5], P=.006) and a mediastinal ratio of 0.5 to 1.0 (hazard ratio 1.9 [95% confidence interval 1.0-3.5], P=.036) were both independent predictors of severe complications. With a mean radiation dose of 24.2 Gy to the future anastomotic region of the gastric fundus, the radiation dose was not associated with the incidence of anastomotic leakage or anastomotic stenosis. The incidence of severe complications was associated with a high superior mediastinal planning target volume border. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Testicular radiation dose after multimodal curative therapy for locally advanced rectal cancer. Influence on hormone levels, quality of life, and sexual functioning

    International Nuclear Information System (INIS)

    Hennies, S.; Wolff, H.A.; Rave-Fraenk, M.; Hess, C.F.; Jung, K.; Gaedcke, J.; Ghadimi, M.; Becker, H.; Hermann, R.M.; Aerztehaus an der Ammerlandklinik, Westerstede; Christiansen, H.; Hannover Medical School

    2012-01-01

    Purpose: The purpose of the current work was to prospectively measure the influence of testicular radiation dose on hormone levels, quality of life (QoL), and sexual functioning following multimodal therapy (neoadjuvant radiochemotherapy, surgery, and adjuvant chemotherapy) for rectal cancer. Patients and methods: From November 2007 to November 2009, 83 male patients were treated at the University of Goettingen with radiochemotherapy (RCT) for locally advanced rectal cancer [total dose 50.4 Gy, concomitant chemotherapy with two cycles of 5-fluorouracil (FU) or 5-FU and oxaliplatin]. Testicular radiation doses were analyzed and correlated with hormone levels [luteinizing hormone (LH), follicle stimulating hormone (FSH), total testosterone and free androgen index (FAI) serum levels], QoL, and sexual functioning, which were determined before and up to 1 year after RCT. Results: Mean dose at the testes was 3.9 Gy (range 0.28-11.98 Gy). It was higher for tumors located < 6 cm from the anocutaneous line (p < 0.05). One year after therapy, testosterone, the testosterone/LH ratio, and the FAI/LH ratio were significantly decreased (3.5-3.0 μg/l, 0.9-0.4, 7.9-4.5, respectively) while LH and FSH (4.2-8.5 IU/l, 6.0-21.9 IU/l) were increased. QoL and sexual functioning were significantly impaired. However, there was no statistical correlation between testicular radiation dose and changes in hormone levels, QoL, or sexual functioning. Conclusion: Multimodal treatment for rectal cancer including RCT leads to hormone level changes and to impaired QoL and sexual functioning. However, because there was no apparent correlation between the analyzed parameters, QoL is probably also influenced by other factors, e.g., psychosocial aspects. (orig.)

  14. Testicular radiation dose after multimodal curative therapy for locally advanced rectal cancer. Influence on hormone levels, quality of life, and sexual functioning

    Energy Technology Data Exchange (ETDEWEB)

    Hennies, S.; Wolff, H.A.; Rave-Fraenk, M.; Hess, C.F. [University Medicine Goettingen (Germany). Dept. of Radiotherapy; Jung, K. [University Medicine Goettingen (Germany). Dept. of Medical Statistics; Gaedcke, J.; Ghadimi, M.; Becker, H. [University Medicine Goettingen (Germany). Dept. of General Surgery; Hermann, R.M. [University Medicine Goettingen (Germany). Dept. of Radiotherapy; Aerztehaus an der Ammerlandklinik, Westerstede (Germany). Radiotherapy; Christiansen, H. [University Medicine Goettingen (Germany). Dept. of Radiotherapy; Hannover Medical School (Germany). Dept. of Radiotherapy

    2012-10-15

    Purpose: The purpose of the current work was to prospectively measure the influence of testicular radiation dose on hormone levels, quality of life (QoL), and sexual functioning following multimodal therapy (neoadjuvant radiochemotherapy, surgery, and adjuvant chemotherapy) for rectal cancer. Patients and methods: From November 2007 to November 2009, 83 male patients were treated at the University of Goettingen with radiochemotherapy (RCT) for locally advanced rectal cancer [total dose 50.4 Gy, concomitant chemotherapy with two cycles of 5-fluorouracil (FU) or 5-FU and oxaliplatin]. Testicular radiation doses were analyzed and correlated with hormone levels [luteinizing hormone (LH), follicle stimulating hormone (FSH), total testosterone and free androgen index (FAI) serum levels], QoL, and sexual functioning, which were determined before and up to 1 year after RCT. Results: Mean dose at the testes was 3.9 Gy (range 0.28-11.98 Gy). It was higher for tumors located < 6 cm from the anocutaneous line (p < 0.05). One year after therapy, testosterone, the testosterone/LH ratio, and the FAI/LH ratio were significantly decreased (3.5-3.0 {mu}g/l, 0.9-0.4, 7.9-4.5, respectively) while LH and FSH (4.2-8.5 IU/l, 6.0-21.9 IU/l) were increased. QoL and sexual functioning were significantly impaired. However, there was no statistical correlation between testicular radiation dose and changes in hormone levels, QoL, or sexual functioning. Conclusion: Multimodal treatment for rectal cancer including RCT leads to hormone level changes and to impaired QoL and sexual functioning. However, because there was no apparent correlation between the analyzed parameters, QoL is probably also influenced by other factors, e.g., psychosocial aspects. (orig.)

  15. Treatment of a long-acting anticoagulant rodenticide poisoning cohort with vitamin K1 during the maintenance period

    Science.gov (United States)

    Long, Jianhai; Peng, Xiaobo; Luo, Yuan; Sun, Yawei; Lin, Guodong; Wang, Yongan; Qiu, Zewu

    2016-01-01

    Abstract Currently, there are few guidelines for the use of vitamin K1 in the maintenance treatment of long-acting anticoagulant rodenticide (LAAR) poisonings. We explored factors in the treatment of LAAR poisoning during the maintenance period in order to suggest feasible treatment models. Data from 24 cases of anticoagulant rodenticide poisoning in our hospital were collected from January 2013 to May 2016. The patients’ sex, age, coagulation function, total time from poisoning to treatment with vitamin K1 (prehospital time), vitamin K1 sustained treatment time (VKSTT), anticoagulant rodenticide category, and specific poison dosage were collected. Multivariate analysis was used to evaluate the correlation between vitamin K1 dosage and other factors during the maintenance period. Only VKSTT (partial regression coefficient −1.133, 0.59, P = 0.035) had an obvious influence on the therapeutic dose of vitamin K1 required during the maintenance period. After an initial pulse therapy, the bleeding and coagulation functions were stabilized, and the patients were subsequently treated with vitamin K1 during the maintenance period. Over time, the maintenance dose of vitamin K1 (10–120 mg/d, intravenous drip) was gradually decreased and was not related to toxicant concentration. PMID:28002326

  16. The Influence of Used Construction Material and Its Thickness on the Neutron Dose Rate Around the Linear Accelerator - Experimental Results

    International Nuclear Information System (INIS)

    Krpan, I; Miklavcic, I.; Poje, M.; Radolic, V.; Vukovic, B.; Zivkovic, A.; Faj, D.; Ivkovic, A.

    2013-01-01

    Since linear accelerators for medical radiotherapy do not have active radioactive sources it makes them adequate from the radioprotection point of view. However, when operating at the energy higher than 10 MeV, they can become a source of unwanted neutron radiation in the giant dipole resonance reaction between the photon beam and the accelerator head material. Neutrons created in this reaction are almost isotropic in direction with an energy range between 700 keV and 1 MeV. During the accelerator installation and different phases of the construction work around the accelerator, a neutron dose rate at several important locations was investigated. Both passive (solid state nuclear track etched detectors - CR 39 and/or LR-115 with the 10B foil) and active detectors (Thermo Biorem FHT 752) were used. A higher photon dose rate was measured around the accelerator facility. An effective photon dose reduction was achieved using steel plates. However, this was the secondary source of neutrons in the reaction between the photons and steel plates, since higher values were measured. Neutron reduction was done by additional layers of barite concrete. A very conservative assessment of the effective dose was done for the medical personnel inside the control room. At the accelerator extreme operating regime (fixed accelerator direction - gantry angle, highest energy possible used), the neutron dose rate in the control room of 12 μSv/h was measured. Knowing the number of working days and number of patients per technician (per day), an exposure to the neutron dose of 1,1 mSv per year was calculated.(author)

  17. The interaction between lipid exchange and thyroid status in the conditions of prolonged influence of small doses of radiation

    Directory of Open Access Journals (Sweden)

    V. L. Sokolenko

    2017-05-01

    Full Text Available We studied the interaction between the indicators of lipid exchange and thyroid status among the inhabitants of radiation contaminated territories under additional psycho-emotional load. We observed 170 students aged between 18–24 and divided them into a control group of students who were from areas unaffected by radiation (70 people and the main experimental group of students from territories of increased radio-ecological load (IV radiation zone, 100 people. We determined the content of thyrotropic hormone (TTH, triiodothyronine (T3, thyroxin (T4, total cholesterin (TC, triglycerides (TG, cholesterin of lipoproteins of high density (Ch-LPHD and cholesterin of lipoproteins of low density (Ch-LPLD. We found that people who had lived since birth in territories which were contaminated with radionuclides and were affected by prolonged influence of small doses of ionizing radiation had significant fluctuations of indicators of concentrations of TTH, T3 and T4, forming manifestations of hypothyroidism and hyperthyrosis among some of those tested. Independently from hyperthyrosis, the effect was accompanied by growth in the level of TH, TG, Ch-LPHD and Ch-LPLD. Persons with manifestations of hypothyroidism had the content of TH above the upper limit of the homeostatic norm and the level of Ch-LPLD was higher than the norm in sub-groups with features of hypo- and hyperthyrosis. All those tested from the main group showed a significant positive correlation connection between the level of TTH and levels of TH and Ch-LPLD. The subgroup with manifestations of hyperthyrosis had a positive correlation between the levels of TTH and TG, the subgroups with manifestations of euthyroidism and hyperthyrosis had a negative correlation between the levels of TTH and Ch-LPHD. The hyperthyrosis subgroup had a significant positive correlation connection between T3 and TH and Ch-LPLD. The euthyroidism and hypothyroidism subgroups had a significant negative correlation

  18. X-ray equipment for dental diagnostics with a dose-rate controller influencing the exposure voltage

    International Nuclear Information System (INIS)

    Franke, K.

    1980-01-01

    If a synoptic picture is taken of teeth or jaw the X-ray tube and the film carrier with the film and a radiation detector are moving around the patient's head. The detector signal is connected to the input of the actual value of the dose-rate controller containing a scanning and stop circuit with a storing time roughly corresponding to the exposure of three teeth. After the shot the actual value of the dose rate is adjusted to the desired value, thus a constant quality of the following pictures being achieved. (RW) [de

  19. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  20. Maintenance work management system

    International Nuclear Information System (INIS)

    Kanai, T.; Takahashi, Y.; Takahashi, K.; Nishino, M.; Takeshige, R.

    2000-01-01

    The maintenance work management system supports the efficient drawing up of various documents for the maintenance work at nuclear power stations and the speeding up of the permission procedure. In addition, it improves the quality assurance of the safety and reliability of the maintenance work. Key merits of the system are: 1. Efficiently drawing up various documents for the maintenance work by using the stored data for the previous maintenance work and the pipe and instrument diagram (P and ID) data. 2. Supporting the management work for the completion of maintenance work safety by using the isolation information stored on the computer system. 3. Speeding up the permission procedure by electronic mail and electronic permission. 4. Displaying additional information such as the specifications of equipment, maintenance result, and maintenance plan by linking up with the database of another system. 5. Reducing the cost of hardware devices by using client/server network configurations of personal computers and a personal computer server. (author)

  1. Unsurfaced Road Maintenance Management

    Science.gov (United States)

    1992-12-01

    This draft manual describes an unsurfaced road maintenance management system for use on military installations. This system is available in either a manual or computerized mode (Micro PAVER). The maintenance standards prescribed should protect Govern...

  2. Winter maintenance performance measure.

    Science.gov (United States)

    2016-01-01

    The Winter Performance Index is a method of quantifying winter storm events and the DOTs response to them. : It is a valuable tool for evaluating the States maintenance practices, performing post-storm analysis, training : maintenance personnel...

  3. Competence within Maintenance

    OpenAIRE

    Nerland, Annette Smørholm

    2010-01-01

    Maintenance can be a contributing factor to unwanted events, as well as desired events and states. Human competence can be defined as the ability to perform a specific task, action or function successfully, and is therefore a key factor to proper execution of maintenance tasks. Hence,maintenance will have negative consequences if done wrong, and give positive results when done right. The purpose of this report is to study the many aspects of maintenance competence. Endeavoring to improve ...

  4. Dynamics of rectal balloon implant shrinkage in prostate VMAT. Influence on anorectal dose and late rectal complication risk

    International Nuclear Information System (INIS)

    Vanneste, Ben G.L.; Wijk, Y. van; Lutgens, L.C.; Limbergen, E.J. van; Lambin, P.; Lin, E.N. van; Beek, K. van de; Hoffmann, A.L.

    2018-01-01

    To assess the effect of a shrinking rectal balloon implant (RBI) on the anorectal dose and complication risk during the course of moderately hypofractionated prostate radiotherapy. In 15 patients with localized prostate cancer, an RBI was implanted. A weekly kilovolt cone-beam computed tomography (CBCT) scan was acquired to measure the dynamics of RBI volume and prostate-rectum separation. The absolute anorectal volume encompassed by the 2 Gy equieffective 75 Gy isodose (V 75Gy ) was recalculated as well as the mean anorectal dose. The increase in estimated risk of grade 2-3 late rectal bleeding (LRB) between the start and end of treatment was predicted using nomograms. The observed acute and late toxicities were evaluated. A significant shrinkage of RBI volumes was observed, with an average volume of 70.4% of baseline at the end of the treatment. Although the prostate-rectum separation significantly decreased over time, it remained at least 1 cm. No significant increase in V 75Gy of the anorectum was observed, except in one patient whose RBI had completely deflated in the third week of treatment. No correlation between mean anorectal dose and balloon deflation was found. The increase in predicted LRB risk was not significant, except in the one patient whose RBI completely deflated. The observed toxicities confirmed these findings. Despite significant decrease in RBI volume the high-dose rectal volume and the predicted LRB risk were unaffected due to a persistent spacing between the prostate and the anterior rectal wall. (orig.) [de

  5. The influence of superlethal γ-radiation doses on the content and metabolism of serotonin in the rat brain

    International Nuclear Information System (INIS)

    Silina, A.G.; Sverdlov, A.G.

    1987-01-01

    As early as 60 min after γ-irradiation of Wistar rats with a dose of 150 Gy the content of serotonin and 5-hydroxyindoleacetic acid decreases in the midbrain, hippocampus, and cerebral hemisphere cortex. The decrease is most pronounced in the midbrain where serotoninergic neurons are located. The changes are accumulated during the first 24 h following irradiation h

  6. The influence of radiation dose on the magnitude and kinetics of reoxygenation in a C3H mammary carcinoma

    International Nuclear Information System (INIS)

    Grau, C.; Overgaard, J.

    1990-01-01

    The variation in hypoxic fraction as a function of time after various priming doses of radiation has been investigated in a C3H mouse mammary carcinoma in situ. The hypoxic fraction was calculated from data for local tumor control. Untreated tumors were found to contain 4.8% radiobiologically hypoxic cells. Within minutes after a priming dose of 20 Gy given in air, the hypoxic fraction increased to a value not significantly different from 100%. After 4 h, reoxygenation was complete (hypoxic fraction 1.3%), and the hypoxic fraction stabilized at a level significantly below the untreated value. Following a priming dose of 40 Gy the reoxygenation pattern was different: The hypoxic fraction stayed above the pretreatment value for 4 h, and pronounced reoxygenation occurred after 12 h (hypoxic fraction 0.4%). At longer time intervals the hypoxic fraction again increased to--and slightly above--the oxygenation level of untreated tumors. The present findings show that reoxygenation in solid tumors is a function of radiation dose, and the data suggest that mechanisms other than a decrease in tumor cell O2 consumption are involved in tumor reoxygenation

  7. SU-E-J-113: The Influence of Optimizing Pediatric CT Simulator Protocols On the Treatment Dose Calculation in Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y; Zhang, J; Hu, Q; Tie, J; Wu, H [Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiotherapy, Peking University Cancer Hospital ' Institute, Beijing (China); Deng, J [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States)

    2014-06-01

    Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with interval of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality

  8. Asphalt in Pavement Maintenance.

    Science.gov (United States)

    Asphalt Inst., College Park, MD.

    Maintenance methods that can be used equally well in all regions of the country have been developed for the use of asphalt in pavement maintenance. Specific information covering methods, equipment and terminology that applies to the use of asphalt in the maintenance of all types of pavement structures, including shoulders, is provided. In many…

  9. Optimization of surface maintenance

    International Nuclear Information System (INIS)

    Oeverland, E.

    1990-01-01

    The present conference paper deals with methods of optimizing the surface maintenance of steel-made offshore installations. The paper aims at identifying important approaches to the problems regarding the long-range planning of an economical and cost effective maintenance program. The methods of optimization are based on the obtained experiences from the maintenance of installations on the Norwegian continental shelf. 3 figs

  10. Dukovany NPP maintenance management

    International Nuclear Information System (INIS)

    Siegel, F.

    2005-01-01

    Maintenance planning and management for the technological equipment of the Dukovany NPP are described. A Maintenance Control and Evaluation System has been developed and is in use to help manage the complex maintenance issue. Practical examples of outputs of the System, with a comprehensive use of the cost, reliability and safety related data, are presented. (author)

  11. Influence of daily setup measurements and corrections on the estimated delivered dose during IMRT treatment of prostate cancer patients

    International Nuclear Information System (INIS)

    Haaren, Paul M.A. van; Bel, Arjan; Hofman, Pieter; Vulpen, Marco van; Kotte, Alexis N.T.J.; Heide, Uulke A. van der

    2009-01-01

    Purpose: To evaluate the impact of marker-based position verification, using daily imaging and an off-line correction protocol, by calculating the delivered dose to prostate, rectum and bladder. Methods: Prostate cancer patients (n = 217) were treated with IMRT, receiving 35 daily fractions. Plans with five beams were optimized taking target coverage (CTV, boost) and organs-at-risk (rectum and bladder) into account. PTV margins were 8 mm. Prostate position was verified daily using implanted fiducial gold markers by imaging the first segment of all the five beams on an EPID. Setup deviations were corrected off-line using an adapted shrinking-action-level protocol. The estimated delivered dose, including daily organ movements, was calculated using a version of PLATO's dose engine, enabling batch processing of large numbers of patients. The dose was calculated ± inclusion of setup corrections, and was evaluated relative to the original static plan. The marker-based measurements were considered representative for all organs. Results: Daily organ movements would result in an underdosage of 2-3 Gy to CTV and boost volume relative to the original plan, which was prevented by daily setup corrections. The dose to rectum and bladder was on average unchanged, but a large spread was introduced by organ movements, which was reduced by including setup corrections. Conclusions: Without position verification and setup corrections, margins of 8mm would be insufficient to account for position uncertainties during IMRT of prostate cancer. With the daily off-line correction protocol, the remaining variations are accommodated adequately

  12. Alterations in water and electrolyte absorption in the rat colon following neutron irradiation: influence of neutron component and irradiation dose.

    Science.gov (United States)

    Dublineau, I; Ksas, B; Joubert, C; Aigueperse, J; Gourmelon, P; Griffiths, N M

    2002-12-01

    To study the absorptive function of rat colon following whole-body exposure to neutron irradiation, either to the same total dose with varying proportion of neutrons or to the same neutron proportion with an increasing irradiation dose. Different proportions of neutron irradiation were produced from the reactor SILENE using a fissile solution of uranium nitrate (8, 47 and 87% neutron). Water and electrolyte fluxes were measured in the rat in vivo under anaesthesia by insertion into the descending colon of an agarose gel cylinder simulating the faeces. Functional studies were completed by histological analyses. In the first set of experiments, rats received 3.8 Gy with various neutron percentages and were studied from 1 to 14 days after exposure. In the second set of experiments, rats were exposed to increasing doses of irradiation (1-4Gy) with a high neutron percentage (87%n) and were studied at 4 days after exposure. The absorptive capacity of rat colon was diminished by irradiation at 3-5 days, with a nadir at 4 days. The results demonstrate that an increase in the neutron proportion is associated with an amplification of the effects. Furthermore, a delay in the re-establishment of normal absorption was observed with the high neutron proportion (87%n). A dose-dependent reduction of water absorption by rat colon was also observed following neutron irradiation (87%n), with a 50% reduction at 3 Gy. Comparison of this dose-effect curve with the curve obtained following gamma (60)Co-irradiation indicates an RBE of 2.2 for absorptive colonic function in rat calculated at 4 days after exposure.

  13. Principal Component Analysis-Based Pattern Analysis of Dose-Volume Histograms and Influence on Rectal Toxicity

    International Nuclear Information System (INIS)

    Soehn, Matthias; Alber, Markus; Yan Di

    2007-01-01

    Purpose: The variability of dose-volume histogram (DVH) shapes in a patient population can be quantified using principal component analysis (PCA). We applied this to rectal DVHs of prostate cancer patients and investigated the correlation of the PCA parameters with late bleeding. Methods and Materials: PCA was applied to the rectal wall DVHs of 262 patients, who had been treated with a four-field box, conformal adaptive radiotherapy technique. The correlated changes in the DVH pattern were revealed as 'eigenmodes,' which were ordered by their importance to represent data set variability. Each DVH is uniquely characterized by its principal components (PCs). The correlation of the first three PCs and chronic rectal bleeding of Grade 2 or greater was investigated with uni- and multivariate logistic regression analyses. Results: Rectal wall DVHs in four-field conformal RT can primarily be represented by the first two or three PCs, which describe ∼94% or 96% of the DVH shape variability, respectively. The first eigenmode models the total irradiated rectal volume; thus, PC1 correlates to the mean dose. Mode 2 describes the interpatient differences of the relative rectal volume in the two- or four-field overlap region. Mode 3 reveals correlations of volumes with intermediate doses (∼40-45 Gy) and volumes with doses >70 Gy; thus, PC3 is associated with the maximal dose. According to univariate logistic regression analysis, only PC2 correlated significantly with toxicity. However, multivariate logistic regression analysis with the first two or three PCs revealed an increased probability of bleeding for DVHs with more than one large PC. Conclusions: PCA can reveal the correlation structure of DVHs for a patient population as imposed by the treatment technique and provide information about its relationship to toxicity. It proves useful for augmenting normal tissue complication probability modeling approaches

  14. Chromatin replication and epigenome maintenance

    DEFF Research Database (Denmark)

    Alabert, Constance; Groth, Anja

    2012-01-01

    Stability and function of eukaryotic genomes are closely linked to chromatin structure and organization. During cell division the entire genome must be accurately replicated and the chromatin landscape reproduced on new DNA. Chromatin and nuclear structure influence where and when DNA replication...... initiates, whereas the replication process itself disrupts chromatin and challenges established patterns of genome regulation. Specialized replication-coupled mechanisms assemble new DNA into chromatin, but epigenome maintenance is a continuous process taking place throughout the cell cycle. If DNA...

  15. Synthesis of poly (acrylamide-co-metacrylic acid) hydrogels By means of gamma irradiation techniques: influence of Absorbed dose on the swelling process

    International Nuclear Information System (INIS)

    Rapado, Manuel; Altanes, Sonia; Sainz, Dianelys; Prado, Stalina

    1999-01-01

    In this report gamma radiation techniques were performed a double function of proceeding the processes of polymerization and crosslinking with the advantage of avoid the uses of chemicals crosslinks. The influence of absorbed dose on the swelling ratio as a function of pH have been presented. For these hydrogels, swelling studies indicated that swelling decrease with the increase of the absorbed dose from 10 to 50 kGy. It was confirmed that at the firsts stages (100-150 min) the diffusion studies were in accordance with Fickian behavior and the diffusion coefficients were obtained, whereas the latest stages were in good agreement with second-order diffusion kinetics proposed by Schott 1 .These news hydrogels exhibit a higher degree of swelling, a factor that, a priori, assures high biocompatibility because it increases the similarity with living tissues

  16. Modeling the influence of high dose irradiation on the deformation and damage behavior of RAFM steels under low cycle fatigue conditions

    Energy Technology Data Exchange (ETDEWEB)

    Aktaa, J. [Forschungszentrum Karlsruhe GmbH, Institute for Materials Research II, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)], E-mail: aktaa@imf.fzk.de; Petersen, C. [Forschungszentrum Karlsruhe GmbH, Institute for Materials Research II, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2009-06-01

    A viscoplastic deformation damage model developed for RAFM steels in the reference un-irradiated state was modified taking into account the irradiation influence. The modification mainly consisted in adding an irradiation hardening variable with an appropriate evolution equation including irradiation dose driven terms as well as inelastic deformation and thermal recovery terms. With this approach, the majority of the material and temperature dependent model parameters are no longer dependent on the irradiation dose and only few parameters need to be determined by applying the model to RAFM steels in the irradiated state. The modified model was then applied to describe the behavior of EUROFER 97 observed in the post irradiation examinations of the irradiation programs ARBOR 1, ARBOR 2 and SPICE. The application results will be presented and discussed in addition.

  17. EPR design for maintenance

    International Nuclear Information System (INIS)

    Krugmann, U.

    1998-01-01

    Preventive maintenance is very important in achieving high plant availability. For the European Pressurized Reactor (EPR) preventive maintenance has been carefully addressed in the design stage. This is particularly necessary because of the traditionally different maintenance strategies employed in France and Germany. This paper emphasizes the following features introduced in the ERP design to minimize the duration of the refueling outage: (1) containment accessibility during power operation; (2) overall plant layout to facilitate inspections and maintenances within the containment; and (3) safety system design for enabling preventive maintenance during power operation. (author)

  18. Modern electronic maintenance principles

    CERN Document Server

    Garland, DJ

    2013-01-01

    Modern Electronic Maintenance Principles reviews the principles of maintaining modern, complex electronic equipment, with emphasis on preventive and corrective maintenance. Unfamiliar subjects such as the half-split method of fault location, functional diagrams, and fault finding guides are explained. This book consists of 12 chapters and begins by stressing the need for maintenance principles and discussing the problem of complexity as well as the requirements for a maintenance technician. The next chapter deals with the connection between reliability and maintenance and defines the terms fai

  19. Managing nuclear maintenance

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    For utilities operating nuclear powerplants, the rules of the game continue to change. Conflicting regulatory pressures and a tougher competitive environment will make management's job more complicated and difficult in the 1990s. Dealing with these pressures successfully requires greater attention to maintenance effectiveness. Utilities can help shape their future environment by developing a well-planned strategy to guide their actions. Parts of the strategy that are discussed include developing a sound maintenance philosophy, selecting a service company, radiation exposure, and managing spare parts. This article also addresses the Swedish experience in maintenance, German philosophy regarding maintenance and the current maintenance practices of the Electricite de France

  20. AIRCRAFT MAINTENANCE HANGAR

    Directory of Open Access Journals (Sweden)

    GEAMBASU Gabriel George

    2017-05-01

    Full Text Available The paper presents the maintenance process that is done on an airplane, at a certain period of time, or after a number of flight hours or cycles and describes the checks performed behind each inspection. The first part of research describes the aircraft maintenance process that has to be done after an updated maintenance manual according with aircraft type, followed by a short introduction about maintenance hangar. The second part of the paper presents a hangar design with a foldable roof and walls, which can be folded or extended, over an airplane when a maintenance process is done, or depending on weather condition.

  1. Influence of macrolide maintenance therapy and bacterial colonisation on exacerbation frequency and progression of COPD (COLUMBUS: Study protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Uzun Sevim

    2012-06-01

    Full Text Available Abstract Background Chronic obstructive pulmonary disease (COPD is characterised by progressive development of airflow limitation that is poorly reversible. Because of a poor understanding of COPD pathogenesis, treatment is mostly symptomatic and new therapeutic strategies are limited. There is a direct relationship between the severity of the disease and the intensity of the inflammatory response. Besides smoking, one of the hypotheses for the persistent airway inflammation is the presence of recurrent infections. Macrolide antibiotics have bacteriostatic as well as anti-inflammatory properties in patients with cystic fibrosis and other inflammatory pulmonary diseases. There is consistent evidence that macrolide therapy reduces infectious exacerbations, decreases the requirement for additional antibiotics and improves nutritional measures. Because of these positive effects we hypothesised that maintenance macrolide therapy may also have beneficial effects in patients with COPD who have recurrent exacerbations. The effects on development of bacterial resistance to macrolides due to this long-term treatment are unknown. Until now, studies investigating macrolide therapy in COPD are limited. The objective of this study is to assess whether maintenance treatment with macrolide antibiotics in COPD patients with three or more exacerbations in the previous year decreases the exacerbation rate in the year of treatment and to establish microbial resistance due to the long-term treatment. Methods/design The study is set up as a prospective randomised double-blind placebo-controlled single-centre trial. A total of 92 patients with COPD who have had at least three exacerbations of COPD in the previous year will be included. Subjects will be randomised to receive either azithromycin 500 mg three times a week or placebo. Our primary endpoint is the reduction in the number of exacerbations of COPD in the year of treatment. Discussion We investigate whether

  2. Does mean heart dose sufficiently reflect coronary artery exposure in left-sided breast cancer radiotherapy. Influence of respiratory gating

    Energy Technology Data Exchange (ETDEWEB)

    Becker-Schiebe, Martina [Klinikum Braunschweig, Department of Radiotherapy and Radio-Oncology, Braunschweig (Germany); Hannover Medical School, Radiation Oncology, Hannover (Germany); Stockhammer, Maxi; Franz, Heiko [Klinikum Braunschweig, Department of Gynecology and Obstetrics, Braunschweig (Germany); Hoffmann, Wolfgang; Wetzel, Fabian [Klinikum Braunschweig, Department of Radiotherapy and Radio-Oncology, Braunschweig (Germany)

    2016-09-15

    With extensive use of systemic treatment, the issue of cardiac mortality after breast cancer radiation (RT) is still important. The aim of our analysis was to clarify whether the dose to one surrogate parameter (e. g., mean heart dose, as used in most studies) reflects the dose to the other cardiovascular structures especially the left anterior descending artery depending on breathing-adapted RT. A total of 130 patients who underwent adjuvant RT (50.4 Gy plus boost 9-16 Gy) were evaluated. In all, 71 patients were treated with free-breathing and 59 patients using respiratory monitoring (gated RT). Dosimetric associations were calculated. The mean dose to the heart (Dmean heart) was reduced from 2.7 (0.8-5.2) Gy to 2.4 (1.1-4.6) Gy, the Dmean LAD (left anterior descending artery) decreased from 11.1 (1.3-28.6) Gy to 9.3 (2.2-19.9) Gy with gated RT (p = 0.04). A significant relationship was shown for Dmean{sub heart}-Dmean LAD, V25heart-Dmean LAD and Dmax heart-Dmax LAD for gated patients only (p < 0.01). For every 1 Gy increase in Dmean heart, mean LAD doses rose by 3.6 Gy, without gating V25 ≤5 % did not assure a benefit and resulted in Dmean LAD between 1.3 and 28.6 Gy. A significant reduction and association of heart and coronary artery (LAD) doses using inspiratory gating was shown. However, in free-breathing plans commonly measured dose constraints do not allow precise estimation of the dose to the coronary arteries. (orig.) [German] Das Risiko kardialer Spaetfolgen nach Bestrahlung (RT) eines Mammakarzinoms spielt insbesondere auch aufgrund der zunehmenden systemischen Begleittherapien eine wichtige Rolle. Unklar ist, welche koronaren und/oder myokardialen Mechanismen hier entscheidend sind. Der Einfluss der Atemtriggerung und der daraus resultierenden geometrischen Lagevariabilitaet der Risikoorgane auf die Dosisverteilung am Herzen/Koronarien sollte geprueft werden, um zu klaeren, inwieweit die mittlere Herzdosis ein ausreichender Surrogatparameter fuer

  3. Influence of the rate of conversion of HT and HTO on projected radiation doses from release of molecular tritium

    International Nuclear Information System (INIS)

    Jacobs, D.G.; Easterly, C.E.; Phillips, J.E.

    1979-01-01

    Releases of tritium in the past have been largely in the form of tritiated water, and the projected radiation doses could be estimated by assuming tritium behaviour to parallel that of water. There is increasing interest in potential releases of tritium in the form of HT because of significant recent advances in fusion reactor research. Several recent studies have shown that bacteria containing the enzyme hydrogenase can catalyse the conversion of HT to HTO at rates several orders of magnitude faster than the rates measured in atmospheric systems. Rates of conversion in the soil have been combined with estimates of rates of permeation of HT into the soil and with global and local models depicting tritium transport and cycling. The results suggest that for the expected conversion rates, the impact on projected radiation doses should be relatively minor. (author)

  4. Influence of fractionation of dose on 3 year results of X-ray therapy of skin cancer

    International Nuclear Information System (INIS)

    Szymczyk, W.; Radziszewska, J.; Cyplik, I.; Glinska, H.

    1985-01-01

    Three-year results of X-ray therapy of skin cancer in 345 patients are presented. The dependence of results on the size of irradiated field and the method of dose fractionation is analysed. The clinical usefulness of a cumulative radiation effect (CRE) is evaluated. 96.5% of three-year cures were obtained. Recurrences amounted to 1.6% and necroses to 1.9% of treated lesions. It has been shown that treatment of small fields with 8-fractions gave equally positive results as with 15-fractions whereas in the treatment of large lesions the selection of CRE value, a number of fractions and dose should let the value of CRE minimally exceeds the level of tolerance of healthy tissues. The regard to CRE value in the treatment of large lesions or the introduction of additional dosimetric acts seems to be useful. 10 refs., 1 fig., 5 tabs. (author)

  5. Evaluation of physiological parameters and their influence on doses calculated from two alternative dosimetric models for the gastrointestinal tract

    International Nuclear Information System (INIS)

    Lessard, E.T.; Skrable, K.W.

    1981-01-01

    Two dosimetric models, the catenary compartmental model and the slug flow model are examined using three sets of physiological parameters. The impact of physiological parameters on the dosimetry of the tract is illustrated by comparing calculated maximum permissible daily activity ingestion rates for single, unabsorbed, particle emitting radionuclides with an effective energy term of unity. The conclusions drawn from this intercomparison of six different cases are: (1) Current dosimetric models which use physiological parameters described in this article do not significantly disagree, and (2) For the determination of average dose equivalent rates to segments of the tract due to chronic, long term ingestion of any radionuclide, the catenary compartmental model is a mathematically simpler approach. The catenary model in addition has certain advantages for the calculation of the photon dose contribution to one segment from cumulated activity (disintegrations) in another segment

  6. Changes in the electrical properties of pure and doped polymers under the influence of small doses of X-rays

    Science.gov (United States)

    Mahmoud, S. A.; Madi, N. K.; Kassem, M. E.; El-Khatib, A.

    A study has been made of the temperature dependence of the d.c. conductivity of pure and borated low density polyethylene LDPE (4% and 8% borax). The above calculations were carried out before and after X-ray irradiation. The irradiation dose was varied from 0 to 1000 rad. The d.c. electrical conductivity of Polyvinyl chloride (PVC) and perspex was measured as a function of temperature ranging from 20°C to 100°C. These samples were irradiated with X-rays of dose 200 rad. The variation of the d.c. conductivity of the treated samples versus temperature was investigated. The results reveal that the d.c. conductivity of LDPE is highly affected by radiation and/or dopant. In addition, the sensitivity of the explored polymers to X-ray irradiation is strongly dependent on its chemical nature.

  7. The influence of whole-body γ-irradiation with low doses on enzyme activity of rat adrenal medulla

    International Nuclear Information System (INIS)

    Amvros'ev, A.P.; Shostak, Yu.A.

    1991-01-01

    A study was made of the pattern of changes in histological indices of key enzymes of the tricarbonic acid cycle (succinate dehydrogenase) and glycolysis (lactate dehydrogenase) as well as of catecholamines (monoamine oxidase) in cells of the adrenal medulla of young and adult albino rats subjected to external whole-body γ-irradiation with doses of 0.5 and 1.0 Gy (dose-rate of 2.7·10 -4 Gy/s). Radiosensitivity of the enzyme systems under study in the adrenal gland cells of young animals was higher than in that of adult. Changes of their levels in different periods of observation were mainly of phase nature and indicated the development of adaptation syndrome in the animal organism

  8. Influence of valproate on the required dose of propofol for anesthesia during electroconvulsive therapy of bipolar affective disorder patients

    Directory of Open Access Journals (Sweden)

    Hızlı Sayar G

    2014-03-01

    Full Text Available Gökben Hizli Sayar, Gül Eryilmaz, Siban Şemieoğlu, Eylem Özten, Işil Göğcegöz Gül Uskudar University, Neuropsychiatry Istanbul Hospital, Istanbul, Turkey Background: Propofol is often used as an anesthetic agent for electroconvulsive therapy (ECT. In recent studies, propofol was shown to possess significant seizure-shortening properties during ECT. "Valproate" is a mood stabilizer used mainly in the treatment of bipolar affective disorder. It is reported that valproate, being an anticonvulsant, raises the seizure threshold, thus decreases the efficacy of ECT treatment. Aim: The purpose of our study was to compare the dose of propofol in valproate-using patients and valproate-free patients. Methods: In an open design, 17 patients with bipolar affective disorder manic episodes who were to be treated with valproate and ECT in combination, were compared with 16 manic-episode patients who were to be treated with ECT but not valproate. The two groups were compared on the basis of electroencephalography-registered seizure duration and the propofol dosage required to induce anesthesia. Results: Valproate, compared with no valproate treatment, results in a decrease in the propofol dose required to induce anesthesia. In the valproate group of study participants, seizure duration was significantly shorter than in the valproate-free group. Conclusion: The results suggest that valproate reduces the dose of propofol required for anesthesia during ECT treatment in patients with bipolar affective disorder manic episodes. Although propofol is a safe and efficacious anesthetic for ECT treatment, lower doses of propofol should be used to induce anesthesia for patients under valproate treatment. When the clinician needs to prolong seizure duration in patients treated with valproate, interruption of the valproate treatment or an anesthetic agent other than propofol should be considered. Keywords: bipolar affective disorder, ECT, anticonvulsant, mood

  9. Influence of Vehicles Used for Oral Dosing of Test Molecules on the Progression of Mycobacterium tuberculosis Infection in Mice

    OpenAIRE

    Singh, Shubhra; Dwivedi, Richa; Chaturvedi, Vinita

    2014-01-01

    Preclinical evaluation of drug-like molecules requires their oral administration to experimental animals using suitable vehicles. We studied the effect of oral dosing with corn oil, carboxymethyl cellulose, dimethyl sulfoxide, and polysorbate-80 on the progression of Mycobacterium tuberculosis infection in mice. Infection was monitored by physical (survival time and body weight) and bacteriological (viable counts in lungs) parameters. Compared with water, corn oil significantly improved both ...

  10. Iron oxide nanoparticle agglomeration influences dose rates and modulates oxidative stress-mediated dose–response profiles in vitro

    Science.gov (United States)

    Sharma, Gaurav; Kodali, Vamsi; Gaffrey, Matthew; Wang, Wei; Minard, Kevin R.; Karin, Norman J.; Teeguarden, Justin G.; Thrall, Brian D.

    2014-01-01

    Spontaneous agglomeration of engineered nanoparticles (ENPs) is a common problem in cell culture media which can confound interpretation of in vitro nanotoxicity studies. The authors created stable agglomerates of iron oxide nanoparticles (IONPs) in conventional culture medium, which varied in hydrodynamic size (276 nm–1.5 μm) but were composed of identical primary particles with similar surface potentials and protein coatings. Studies using C10 lung epithelial cells show that the dose rate effects of agglomeration can be substantial, varying by over an order of magnitude difference in cellular dose in some cases. Quantification by magnetic particle detection showed that small agglomerates of carboxylated IONPs induced greater cytotoxicity and redox-regulated gene expression when compared with large agglomerates on an equivalent total cellular IONP mass dose basis, whereas agglomerates of amine-modified IONPs failed to induce cytotoxicity or redox-regulated gene expression despite delivery of similar cellular doses. Dosimetry modelling and experimental measurements reveal that on a delivered surface area basis, large and small agglomerates of carboxylated IONPs have similar inherent potency for the generation of ROS, induction of stress-related genes and eventual cytotoxicity. The results suggest that reactive moieties on the agglomerate surface are more efficient in catalysing cellular ROS production than molecules buried within the agglomerate core. Because of the dynamic, size and density-dependent nature of ENP delivery to cells in vitro, the biological consequences of agglomeration are not discernible from static measures of exposure concentration (μg/ml) alone, highlighting the central importance of integrated physical characterisation and quantitative dosimetry for in vitro studies. The combined experimental and computational approach provides a quantitative framework for evaluating relationships between the biocompatibility of nanoparticles and their

  11. Maintenance management systems

    International Nuclear Information System (INIS)

    Rohan, M. de

    1989-01-01

    This paper is concerned principally with Maintenance Management systems and their effective introduction into organisations. Maintenance improvement is basically a problem of managing the maintenance department in the broadest sense. Improvement does not only lie in the area of special techniques, systems or procedures; although they are valuable tools, but rather in a balanced attack, carefully guided by management. Over recent years, maintenance systems have received the major emphasis and in many instances the selection of the system has become a pre-occupation, whereas the importance of each maintenance function must be recognised and good management practices applied to all maintenance activities. The ingredients for success in the implementation of maintenance management systems are summarised as: having a management committee, clear objectives, project approach using project management techniques and an enthusiastic leader, user managed and data processing supported project, realistic budget and an understanding of the financial audit requirements. (author)

  12. Knowledge based maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Sturm, A [Hamburgische Electacitaets-Werke AG Hamburg (Germany)

    1998-12-31

    The establishment of maintenance strategies is of crucial significance for the reliability of a plant and the economic efficiency of maintenance measures. Knowledge about the condition of components and plants from the technical and business management point of view therefore becomes one of the fundamental questions and the key to efficient management and maintenance. A new way to determine the maintenance strategy can be called: Knowledge Based Maintenance. A simple method for determining strategies while taking the technical condition of the components of the production process into account to the greatest possible degree which can be shown. A software with an algorithm for Knowledge Based Maintenance leads the user during complex work to the determination of maintenance strategies for this complex plant components. (orig.)

  13. Knowledge based maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Sturm, A. [Hamburgische Electacitaets-Werke AG Hamburg (Germany)

    1997-12-31

    The establishment of maintenance strategies is of crucial significance for the reliability of a plant and the economic efficiency of maintenance measures. Knowledge about the condition of components and plants from the technical and business management point of view therefore becomes one of the fundamental questions and the key to efficient management and maintenance. A new way to determine the maintenance strategy can be called: Knowledge Based Maintenance. A simple method for determining strategies while taking the technical condition of the components of the production process into account to the greatest possible degree which can be shown. A software with an algorithm for Knowledge Based Maintenance leads the user during complex work to the determination of maintenance strategies for this complex plant components. (orig.)

  14. Influence of dose rate on the transformation of Syrian hamster embryo cells by fission-spectrum neutrons

    International Nuclear Information System (INIS)

    Jones, C.A.; Sedita, B.A.; Hill, C.K.; Elkind, M.M.

    1988-01-01

    Several explanations for this neutron dose-rate effect have been proposed, but further investigation is necessary to determine the mechanisms involved. In all cell transformation studies to date the immortalized, aneuploid 10T1/2 cell-line has been used. These cells may be premalignant; thus their response characteristics and, in particular, the nature of the transformation event, might differ from that in a normal, fibroblast cell. One reason for the present study was to determine whether the low-dose-rate effect of fission neutrons could be demonstrated in normal cells. If so, a normal cell system, which would more closely resemble a normal in vivo system, could be used for mechanistic studies. We chose Syrian hamster embryo (SHE) fibroblasts which are normal, diploid cells with a limited life span in culture. Upon exposure to low doses of ionizing radiation, the fraction of the cells that are transformed can be identified in a standard 8--10 day colony assay by examining their clonal morphology. Transformed cells form colonies with a dense, criss-crossed or piled-up structure. A high percentage of the transformed colonies can be further propagated and will acquire additional neoplastic characteristics; i.e., anchorage independence, immortality, altered proteolytic activity, karyotype alterations, and finally, tumorigenicity

  15. Influence of various doses of gamma irradiation on the germination and growth of mango (mangifera indica lin) stones

    International Nuclear Information System (INIS)

    Hafiz, I.A.; Malik, F.A.; Ahmad, S.; Asi, A.A.; Khan, M.

    2004-01-01

    Mango stones of the cultivar, Dusehri were administered the Gamma irradiation sourced from cobalt-60 with the doses of 0, 2.5, 5.0, 7.5, 10.00, 12.50 and 15.00 Krd. The results had revealed that the germination percentage was significantly different amongst the treatments, which was slightly improved at 2.5 Krd with the value of 87. 5 %, compared with control (70.25 %), but this pattern showed the reduced trend at higher levels of radiation doses. Germination percentage had geared the negative trend beyond the dose of 2. 5 Krd. Inhibitory effects of radiation were observed pertinent to the average height of seedlings. However, primary leaves appeared serrated in the seedlings emerged from the treated seeds, which turned normal in the subsequent growth of flushes. A new characteristic of lateral branching instead of keeping a single stem was exhibited in the seedlings derived from the treated seeds. The induction of the trait may be used to alter the structure/framework/pattern of the tree canopy. (author)

  16. Influence of dose rate on the transformation of Syrian hamster embryo cells by fission-spectrum neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.A.; Sedita, B.A.; Hill, C.K.; Elkind, M.M.

    1988-01-01

    Several explanations for this neutron dose-rate effect have been proposed, but further investigation is necessary to determine the mechanisms involved. In all cell transformation studies to date the immortalized, aneuploid 10T1/2 cell-line has been used. These cells may be premalignant; thus their response characteristics and, in particular, the nature of the transformation event, might differ from that in a normal, fibroblast cell. One reason for the present study was to determine whether the low-dose-rate effect of fission neutrons could be demonstrated in normal cells. If so, a normal cell system, which would more closely resemble a normal in vivo system, could be used for mechanistic studies. We chose Syrian hamster embryo (SHE) fibroblasts which are normal, diploid cells with a limited life span in culture. Upon exposure to low doses of ionizing radiation, the fraction of the cells that are transformed can be identified in a standard 8--10 day colony assay by examining their clonal morphology. Transformed cells form colonies with a dense, criss-crossed or piled-up structure. A high percentage of the transformed colonies can be further propagated and will acquire additional neoplastic characteristics; i.e., anchorage independence, immortality, altered proteolytic activity, karyotype alterations, and finally, tumorigenicity.

  17. Magnetic field influences on the lateral dose response functions of photon-beam detectors: MC study of wall-less water-filled detectors with various densities.

    Science.gov (United States)

    Looe, Hui Khee; Delfs, Björn; Poppinga, Daniela; Harder, Dietrich; Poppe, Björn

    2017-06-21

    The distortion of detector reading profiles across photon beams in the presence of magnetic fields is a developing subject of clinical photon-beam dosimetry. The underlying modification by the Lorentz force of a detector's lateral dose response function-the convolution kernel transforming the true cross-beam dose profile in water into the detector reading profile-is here studied for the first time. The three basic convolution kernels, the photon fluence response function, the dose deposition kernel, and the lateral dose response function, of wall-less cylindrical detectors filled with water of low, normal and enhanced density are shown by Monte Carlo simulation to be distorted in the prevailing direction of the Lorentz force. The asymmetric shape changes of these convolution kernels in a water medium and in magnetic fields of up to 1.5 T are confined to the lower millimetre range, and they depend on the photon beam quality, the magnetic flux density and the detector's density. The impact of this distortion on detector reading profiles is demonstrated using a narrow photon beam profile. For clinical applications it appears as favourable that the magnetic flux density dependent distortion of the lateral dose response function, as far as secondary electron transport is concerned, vanishes in the case of water-equivalent detectors of normal water density. By means of secondary electron history backtracing, the spatial distribution of the photon interactions giving rise either directly to secondary electrons or to scattered photons further downstream producing secondary electrons which contribute to the detector's signal, and their lateral shift due to the Lorentz force is elucidated. Electron history backtracing also serves to illustrate the correct treatment of the influences of the Lorentz force in the EGSnrc Monte Carlo code applied in this study.

  18. Influence of the neutron flux shape on the value of absorbed neutron dose; Uticaj oblika neutronskog spektra na vrednost apsorbovane doze neutrona

    Energy Technology Data Exchange (ETDEWEB)

    Miric, I; Miric, P [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1974-07-01

    This paper deals with the study od specific doses dependence on the type and approximation procedures of neutron spectra. Values of specific dose rates (dose per neutron cm{sub 2}) were analysed for neutron spectra from RB reactor in Vinca, Crac facility in Valduc (France) and HPRR reactor in Oak Ridge (USA). Data used in this analysis were obtained by methods used in Harwell (AERE), Oak Ridge (ORNL), Chalk River (AECL), CEN de Cadarache (CEA) and in the Boris Kidric Institute (IBK). Specific absorbed neutron doses were determined for each of the estimated spectra and presented in the form of kerma/(n.cm{sup -2}) and rad/((n.cm{sup -2}) units. The obtained results have shown the influence of the flux approximation procedure on the values of conversion factors for obtaining neutron doses from neutron flux. U okviru ovog rada radjeno je na ispitivanju zavisnosti specificnih doza od vrste i nacina aproksimacije neutronskog spektra. U radu su analizirane vrednosti specificnih doza (doza po n.cm{sup -2}) za neutronske spektre koji se dobijaju oko sledecih nuklearnih postrojenja: reaktora RB u Vinci, postrojenja CRAC u Valduc-u (Francuska), reaktora HPRR u Oak Ridge-u (SAD). Za analizu su korisceni podaci dobijeni metodama koje se koriste u nuklearnim centrima Harwell (AERE), Oak Ridge-u (ORNL), Chalk River-u (AECL), CEN de Cadarache (CEA) i Institutu Boris Kidric (IBK). Za svaki procenjeni spektar odredjene su specificne apsorbovane doze neutrona izrazene u kerma/(n.cm{sup -2}) i rad/(n.cm{sup -2}) jedinicama. Dobijeni rezultati su pokazali koliko nacin aproksimacije spektra utice na vrednost konverzionih faktora koji sluze za prelazak sa fluksa na dozu neutrona (author)

  19. The Influence of Infective Dose on the Virulence of a Generalist Pathogen in Rainbow Trout (Oncorhynchus mykiss and Zebra Fish (Danio rerio.

    Directory of Open Access Journals (Sweden)

    Hanna Kinnula

    Full Text Available Pathogen density and genetic diversity fluctuate in the outside-host environment during and between epidemics, affecting disease emergence and the severity and probability of infections. Although the importance of these factors for pathogen virulence and infection probability has been acknowledged, their interactive effects are not well understood. We studied how an infective dose in an environmentally transmitted opportunistic fish pathogen, Flavobacterium columnare, affects its virulence both in rainbow trout, which are frequently infected at fish farms, and in zebra fish, a host that is not naturally infected by F. columnare. We used previously isolated strains of confirmed high and low virulence in a single infection and in a co-infection. Infection success (measured as host morbidity correlated positively with dose when the hosts were exposed to the high-virulence strain, but no response for the dose increase was found when the hosts were exposed to the low-virulence strain. Interestingly, the co-infection resulted in poorer infection success than the single infection with the high-virulence strain. The rainbow trout were more susceptible to the infection than the zebra fish but, in both species, the effects of the doses and the strains were qualitatively similar. We suggest that as an increase in dose can lead to increased host morbidity, both the interstrain interactions and differences in infectivity in different hosts may influence the severity and consequently the evolution of disease. Our results also confirm that the zebra fish is a good laboratory model to study F. columnare infection.

  20. The influences of adrenaline dosing frequency and dosage on outcomes of adult in-hospital cardiac arrest: A retrospective cohort study.

    Science.gov (United States)

    Wang, Chih-Hung; Huang, Chien-Hua; Chang, Wei-Tien; Tsai, Min-Shan; Yu, Ping-Hsun; Wu, Yen-Wen; Hung, Kuan-Yu; Chen, Wen-Jone

    2016-06-01

    To investigate the influence of dosing frequency and dosage of adrenaline on outcomes of cardiopulmonary resuscitation (CPR). We conducted a retrospective observational study in a single medical centre and included adult patients who had suffered an in-hospital cardiac arrest between 2006 and 2012. We used multivariable logistic regression analysis to evaluate the associations between independent variables and outcomes. Adrenaline average dosing frequency was calculated as the total dosage of adrenaline administered during CPR divided by the duration of CPR. Body weight (BW) was analysed as an interaction term to investigate the effect of adrenaline dosage on outcomes. Favourable neurological outcome was defined as a score of 1 or 2 on the Cerebral Performance Category scale at hospital discharge. We included 896 patients in the analysis. After adjusting for multiple confounding factors, including CPR duration, the results indicated that higher adrenaline dosing frequency was associated with lower rates of survival (odds ratio (OR): 0.05, 95% confidence interval (CI): 0.01-0.23) and favourable neurological outcome at hospital discharge (OR: 0.02, 95% CI: 0.002-0.16). A significant interaction was noted between total adrenaline dosage and BW, which indicated that, with the same adrenaline dosage, the outcomes for patients with BW≥82.5kg would be worse than those for patients with lower BW. Higher adrenaline average dosing frequency may be associated with worse outcomes after CPR. Besides, according to current recommendations, patients with BW above 82.5kg may not receive adequate dose of adrenaline. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. The influence of single and fractionated dose external beam irradiation on injury-induced arterial smooth muscle cell proliferation

    International Nuclear Information System (INIS)

    Schaefer, U.; Micke, O.; Dorszewski, A.; Breithardt, G.; Willich, N.

    1997-01-01

    Purpose/Objective: Restenosis after catheter-based revascularization has been demonstrated to be primarily caused by smooth muscle cell proliferation. This study examined the effects of external beam irradiation on neointimal proliferation after external injury to the central artery of the rabbit ear. Materials and Methods: 40 male New Zealand White rabbits were used in this study. Crush lesions were performed on each ear under general anesthesia and bilateral auricular nerve blockade. A single dose of 12 Gy (n=10), 16 Gy (n=10), or 20 Gy (n=10) and a fractionated dose of 4 x 5 Gy (n=10) gamma radiation was delivered to the left or right central artery of the ear 24 hours after injury; the contralateral central artery served as control. All rabbits were sacrificed after twenty-one days and the central arteries of the ear were fixed for morphometric measurements. Results: Mean (± SD) neointimal area was 0.062 ± 0.005 mm 2 (12 Gy), 0.022 ± 0,005 mm 2 (16 Gy), 0,028 ± 0,006 mm 2 and 0.038 mm 2 ± 0,02 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,081 ± 0,009 mm 2 in the control group. Mean (±SD) luminal area was 0.049 ± 0.004 mm 2 (12 Gy), 0.059 ± 0.002 mm 2 (16 Gy), 0.072 ± 0,006 mm 2 (20 Gy) and 0.048 mm 2 ± 0,018 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,043 ± 0,008 mm 2 in the control group. The difference in neointimal and luminal area between control and irradiated arteries was significant (p<0.05) only for the 16 and 20 Gy group compared to control. Conclusion: We conclude that in this model, external beam X-ray irradiation was successful in reducing neointimal proliferation after injury of the central artery of the rabbit ear. The optimal dose seems to be a single dose of 16 Gy - 20 Gy. Only a less prominent effect was noted for a fractionated dose of 4 x 5 Gy. Whether this approach can be used successfully to inhibit restenosis in the clinical setting requires further investigation

  2. Environmental favourable foundries through maintenance activities

    Directory of Open Access Journals (Sweden)

    A. Saniuk

    2015-10-01

    Full Text Available Maintenance today contributes to the aim of sustainable development in society, including environmental and energy saving, safety and economical aspects. The main purpose of the paper is to present the role of maintenance in the realization of sustainable developing practices in a foundry industry. Maintenance offers numerous opportunities to reduce the influence of foundry processes on the natural environment and utilize resources more efficiently. Maintenance activities can help to reduce losses and thereby improve the efficiency of the processes used in the production of resources (e.g. raw materials, energy, etc., especially in areas such as: the choice of an appropriate strategy for the maintenance of machinery and equipment (e.g. reactive, preventive, proactive; inventory management of spare parts; lubrication management and management of technology media.

  3. Plane of nutrition during the preweaned period and Mannheimia haemolytica dose influences inflammatory responses to a combined bovine herpesvirus-1 and Mannheimia haemolytica challenge in post-weaned Holstein calves

    Science.gov (United States)

    To determine whether previous plane of milk replacer nutrition (PON) and M. haemolytica (MH) dose influences inflammatory responses to a combined viral-bacterial respiratory challenge, Holstein calves (1 day of age; n=30) were assigned to treatments in a 2 x 3 factorial with preweaned PON and dose o...

  4. Development and application of a radioactivity evaluation technique the to obtain radiation exposure dose of radioactivity evaluation technique when a severe accident occurs in the a power station of a severe accident. Accident management guidelines of knowledge-based maintenance

    International Nuclear Information System (INIS)

    Kawasaki, Ikuo; Yoshida, Yoshitaka

    2013-01-01

    As a One of the lessons learned from the nuclear accident at the Fukushima Daiichi Nuclear Power Stations of Tokyo Electric Power Company, the was the need for improvement of accident management guidelines is required. In this report study, we developed and applied a dose evaluation technique to evaluated the radiation dose in a nuclear power plant assuming three conditions: employees were evacuation evacuated at the time of a severe accident occurrence; operators carried out the accident management operation; of the operators, and the repair work was carried out for of the trouble damaged apparatuses in a the nuclear power plant using a dose evaluation system. The following knowledge findings were obtained and should to be reflected to in the knowledge base of the guidelines was obtained. (1) By making clearly identifying an areas beforehand becoming the that would receive high radiation doses at the time of a severe accident definitely beforehand, we can employees can be moved to the evacuation places through an areas having of low dose rate and it is also known it how much we long employees can safely stay in the evacuation places. (2) When they circulate CV containment vessel recirculation sump water is recirculated by for the accident management operation and the restoration of safety in the facilities, because the plumbing piping and the apparatuses become radioactive radioactivity sources, the dose evaluation of the shortest access route and detour access routes with should be made for effective the accident management operation is effective. Because the area where a dose rate rises changes which as safety apparatuses are restored, in consideration of a plant state, it is necessary to judge the rightness or wrongness of the work continuation from the spot radioactive dose of the actual apparatus area, with based on precedence of the need to restore with precedence, and to choose a system to be used for accident management. (author)

  5. Influence of low Gamma Irradiation Doses And Weed Control On Faba Bean (VICIA FABA L.) Yield Attributes

    International Nuclear Information System (INIS)

    Farag, I.A.A; Abd El Hameed, I.M

    2013-01-01

    Two field experiments were carried out in an administration field at Belbees district, Sharkia Governorate, Egypt, during two successive winter seasons (2007⁄08-2008⁄09). The study aimed to investigate the effect of four gamma irradiation doses (un irradiated seeds as a control, 10,20 and 30 Gy)and five treatments of weed management practices 1- Un weeded (control), 2- Two hand hoeings at 21 and 42 days after sowing, 3- prometryn, commercially known as Gizagared,, sprayed at pre-emergence with rate of 1 Kg⁄300 liters⁄fad. 4-Bentazon 48⁒, commercially known as Basagran 48⁒ ,sprayed at pre-emergence with the rate of 500 Cm 3 ⁄200 ;liters water⁄fad. Sprayed at pre-emergence. 5-48⁒ sprayed at pre-emergence with the rate of 500 cm 3 ⁄200 liters water⁄fad. On yield and yield attributes of faba bean. Results indicate that :1- Gamma irradiation with the lowest dose of 10 Gy, gave high values for plant height (112.54 cm) and number of pods⁄plant (12.22), while the highest gamma irradiation dose of 30 Gy, resulted in high values for number of seeds⁄pod (4.52), number of seeds⁄plant (52.3) , seed weight (g)⁄plant, 100- seeds weight (79.79 g), seed yield (11.39 ardab⁄fad) and straw yield (ton⁄fad). The lowest values for each of the aforementioned traits were obtained in non irradiated treatment in the combined analysis 2- Weed control by hand hoeing twice (after 21 and 24 DAS) gave the highest values for each of the aforementioned traits, followed by spraying both herbicides., prometryn + bentazon 48⁒ followed by sole herbicide Bentazon 48⁒ and sole prometryn, while unweeded treatment gave the lowest values for the respective order, in the combined analysis.

  6. Influence of low dose irradiation on the quality of fresh buffalo meat stored at 0-3 degrees C

    International Nuclear Information System (INIS)

    Naik, G.N.; Pushpa Paul; Chawla, S.P.; Sherikar, A.T.; Nair, P.M.

    1994-01-01

    The effect of low dose irradiation on the microbiological, chemical and sensory qualities of fresh buffalo meat stored at 0-3-degrees-C was studied. Meat slices packed in polyethylene bags subjected to 2.5 kGydose had a shelf-life of 4 weeks with acceptable sensory score, low total volatile basic nitrogen values and remarkable improvement in microbiological quality. Irradiated meat was completely free of Pseudomonas spp. and Enterobacteriaceae throughout storage. In contrast, the unirradiated control meat spoiled within 2 weeks

  7. Influence of Exposure to Fractionated Dose of Gamma Radiation and Antioxidants Supplementation to Mice on program cell death induction

    International Nuclear Information System (INIS)

    Hanafi, A.

    2010-01-01

    The previous studies reported that the tumor suppressor protein (P53) is not functioning correctly in most human cancers, and that it plays a crucial role in the prevention of tumor development. This study was designed to evaluate if exposure to fractionated dose of gamma radiation impair function of P53 by the administration of antioxidants. Group of control mice was used. Another groups treated with 3 mg/mouse/day of Antox drug which contains the three main antioxidant vitamins (A, C, and E) together with trace element selenium for 15 days. Another group subjected to 1 Gy of gamma radiation 5 times every other day either alone or combined with the Antox drug supplementation. Hepatic and renal functions were evaluated. Antioxidant markers (MDA and GSH) levels, histopathological changes and P53 expression were recorded in liver and kidney tissues. Animals treated with Antox showed some increase in liver transaminases, non significant changes in total protein and albumin levels, a non significant change in kidney function profiles, a non significant increase in MDA and a significant increase in GSH levels in liver and kidney tissues. However, the exposure of mice to fractionated dose of gamma radiation led to a significant increase in kidney function profiles, AST and ALT activity, a significant decrease in total protein and albumin level, a significant increase in MDA levels and a significant decrease in GSH levels in liver and kidney were observed. Exposure of experimental animals post treatment with Antox drug to fractionated dose of gamma radiation revealed a significant amelioration in liver and kidney function profiles, a highly significant decrease in MDA levels and a significant increase in GSH level in comparison with irradiated group. Histopathological changes in liver and kidney recorded the same alterations observed with the biochemical parameters. P53 expression negatively expressed in normal liver and kidney tissues. However, the exposure of mice to

  8. Evaluation of physiological parameters and their influence on doses calculated from two alternative dosimetric models for the gastrointestinal tract

    International Nuclear Information System (INIS)

    Lessard, E.T.; Skrable, K.W.

    1981-01-01

    Two dosimetric models, the catenary compartmental model (Be70) and the slug flow model (Sk75), are examined using three sets of physiological parameters: those proposed by Eve, those proposed by ICRP, and those obtained from the Textbook of Physiology and Biochemistry by Bell et al. The impact of physiological parameters on the dosimetry of the tract is illustrated by comparing calculated maximum permissible daily activity ingestion rates for single, unabsorbed, particle emitting radionuclides with an effective energy term of unity. The conclusions drawn from this intercomparison of six different cases are: Current dosimetric models which use physiological parameters described in this article do not significantly disagree, and for the determination of average dose equivalent rates to segments of the tract due to chronic, long term ingestion of any radionuclide, the catenary compartmental model is a mathematically simpler approach. The catenary model in addition has certain advantages for the calculation of the photon dose contribution to one segment from cumulated activity (disintegrations) in another segment

  9. Influence of the Target Vessel on the Location and Area of Maximum Skin Dose during Percutaneous Coronary Intervention

    International Nuclear Information System (INIS)

    Chida, K.; Fuda, K.; Kagaya, Y.; Saito, H.; Takai, Y.; Kohzuki, M.; Takahash i, S.; Yamada, S.; Zuguchi, M.

    2007-01-01

    Background: A number of cases involving radiation-associated patient skin injury attributable to percutaneous coronary intervention (PCI) have been reported. Knowledge of the location and area of the patient's maximum skin dose (MSD) in PCI is necessary to reduce the risk of skin injury. Purpose: To determine the location and area of the MSD in PCI, and separately analyze the effects of different target vessels. Material and Methods: 197 consecutive PCI procedures were studied, and the location and area of the MSD were calculated by a skin-dose mapping software program: Caregraph. The target vessels of the PCI procedures were divided into four groups based on the American Heart Association (AHA) classification. Results: The sites of the MSD for AHA no.1-3, AHA no.4, and AHA no.11-15 were located mainly on the right back skin, the lower right or center back skin, and the upper back skin areas, respectively, whereas the MSD sites for the AHA no. 5-10 PCI were widely spread. The MSD area for the AHA no. 4 PCI was larger than that for the AHA no. 11-15 PCI (P<0.0001). Conclusion: Although the radiation associated with PCI can be widely spread and variable, we observed a tendency regarding the location and area of the MSD when we separately analyzed the data for different target vessels. We recommend the use of a smaller radiation field size and the elimination of overlapping fields during PCI

  10. Short- and Long-Term Effects of Prenatal Exposure to Iron Oxide Nanoparticles: Influence of Surface Charge and Dose on Developmental and Reproductive Toxicity

    Directory of Open Access Journals (Sweden)

    Kristin R. Di Bona

    2015-12-01

    Full Text Available Iron oxide nanoparticles (NPs are commonly utilized for biomedical, industrial, and commercial applications due to their unique properties and potential biocompatibility. However, little is known about how exposure to iron oxide NPs may affect susceptible populations such as pregnant women and developing fetuses. To examine the influence of NP surface-charge and dose on the developmental toxicity of iron oxide NPs, Crl:CD1(ICR (CD-1 mice were exposed to a single, low (10 mg/kg or high (100 mg/kg dose of positively-charged polyethyleneimine-Fe2O3-NPs (PEI-NPs, or negatively-charged poly(acrylic acid-Fe2O3-NPs (PAA-NPs during critical windows of organogenesis (gestation day (GD 8, 9, or 10. A low dose of NPs, regardless of charge, did not induce toxicity. However, a high exposure led to charge-dependent fetal loss as well as morphological alterations of the uteri (both charges and testes (positive only of surviving offspring. Positively-charged PEI-NPs given later in organogenesis resulted in a combination of short-term fetal loss (42% and long-term alterations in reproduction, including increased fetal loss for second generation matings (mice exposed in utero. Alternatively, negatively-charged PAA-NPs induced fetal loss (22% earlier in organogenesis to a lesser degree than PEI-NPs with only mild alterations in offspring uterine histology observed in the long-term.

  11. In-homogeneity in the pre-dose sensitization of the 110 °C TL peak in various quartz samples: The influence of annealing

    International Nuclear Information System (INIS)

    Polymeris, George S.; Oniya, Ebenezer O.; Jibiri, Nnamdi N.; Tsirliganis, Nestor C.; Kitis, George

    2012-01-01

    The pre-dose sensitization effect of the 110 °C TL glow-peak of quartz is a basic tool in thermoluminescence and optically stimulated luminescence dating and retrospective dosimetry. In the present work, a homogeneity study was performed on pre-dose sensitization in grains obtained from large quartz crystals samples collected from 10 different origins. The aliquot – to – aliquot scatter of the pre-dose sensitization of the 110 °C TL peak within each quartz crystal was monitored. The influence of the annealing on this scattering was also studied. Therefore, the investigation was applied to the un-fired “as is” samples as well as to samples annealed at 900 °C for 1 h following cooling to room temperature in air. The results showed that in the case of “as is” quartz the sensitization effect vary strongly within each aliquot of the same quartz sample. This strong variation is removed by both the high temperature annealing as well as heating up to 500 °C, involved in the TL measurements. These results are generally discussed in the framework of existing models and applications of the effect.

  12. In-homogeneity in the pre-dose sensitization of the 110 Degree-Sign C TL peak in various quartz samples: The influence of annealing

    Energy Technology Data Exchange (ETDEWEB)

    Polymeris, George S., E-mail: polymers@auth.gr [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, Cultural and Educational Technology Institute, Athena, Research and Innovation Center in Information, Communication and Knowledge Technologies, Tsimiski 58, GR-67100 Xanthi (Greece); ISIK University, Faculty of Science and Arts, Physics Department, Sile 34980, Istanbul (Turkey); Oniya, Ebenezer O. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, Cultural and Educational Technology Institute, Athena, Research and Innovation Center in Information, Communication and Knowledge Technologies, Tsimiski 58, GR-67100 Xanthi (Greece); Physics and Electronics Department, Adekunle Ajasin University, PMB 01 Akungba Akoko (Nigeria); Jibiri, Nnamdi N. [Department of Physics, University of Ibadan, Ibadan (Nigeria); Tsirliganis, Nestor C. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, Cultural and Educational Technology Institute, Athena, Research and Innovation Center in Information, Communication and Knowledge Technologies, Tsimiski 58, GR-67100 Xanthi (Greece); Kitis, George [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece)

    2012-03-01

    The pre-dose sensitization effect of the 110 Degree-Sign C TL glow-peak of quartz is a basic tool in thermoluminescence and optically stimulated luminescence dating and retrospective dosimetry. In the present work, a homogeneity study was performed on pre-dose sensitization in grains obtained from large quartz crystals samples collected from 10 different origins. The aliquot - to - aliquot scatter of the pre-dose sensitization of the 110 Degree-Sign C TL peak within each quartz crystal was monitored. The influence of the annealing on this scattering was also studied. Therefore, the investigation was applied to the un-fired 'as is' samples as well as to samples annealed at 900 Degree-Sign C for 1 h following cooling to room temperature in air. The results showed that in the case of 'as is' quartz the sensitization effect vary strongly within each aliquot of the same quartz sample. This strong variation is removed by both the high temperature annealing as well as heating up to 500 Degree-Sign C, involved in the TL measurements. These results are generally discussed in the framework of existing models and applications of the effect.

  13. Random maintenance policies

    CERN Document Server

    Nakagawa, Toshio

    2014-01-01

    Exploring random maintenance models, this book provides an introduction to the implementation of random maintenance, and it is one of the first books to be written on this subject.  It aims to help readers learn new techniques for applying random policies to actual reliability models, and it provides new theoretical analyses of various models including classical replacement, preventive maintenance and inspection policies. These policies are applied to scheduling problems, backup policies of database systems, maintenance policies of cumulative damage models, and reliability of random redundant systems. Reliability theory is a major concern for engineers and managers, and in light of Japan’s recent earthquake, the reliability of large-scale systems has increased in importance. This also highlights the need for a new notion of maintenance and reliability theory, and how this can practically be applied to systems. Providing an essential guide for engineers and managers specializing in reliability maintenance a...

  14. Framework for Maintenance Planning

    DEFF Research Database (Denmark)

    Soares, C. Guedes; Duarte, J. Caldeira; Garbatov, Y.

    2010-01-01

    the design and during the whole life span of operational use, within an integrated framework founded on risk and reliability based techniques. The document addresses designers, decision makers and professionals responsible for or involved in establishing maintenance plans. The purpose of this document......The present document presents a framework for maintenance planning. Maintenance plays a fundamental role in counteracting degradation effects, which are present in all infrastructure and industrial products. Therefore, maintenance planning is a very critical aspect to consider both during...... is to present maintenance as an integrated approach that needs to be planned, designed, engineered, and controlled by proper qualitative and quantitative techniques. This document outlines the basic premises for maintenance planning and provides the general philosophies that can be followed and points to a best...

  15. Suncor maintenance and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Little, S. [Suncor Energy, Calgary, AB (Canada)

    2006-07-01

    Fleet maintenance and reliability at Suncor Energy was discussed in this presentation, with reference to Suncor Energy's primary and support equipment fleets. This paper also discussed Suncor Energy's maintenance and reliability standard involving people, processes and technology. An organizational maturity chart that graphed organizational learning against organizational performance was illustrated. The presentation also reviewed the maintenance and reliability framework; maintenance reliability model; the process overview of the maintenance and reliability standard; a process flow chart of maintenance strategies and programs; and an asset reliability improvement process flow chart. An example of an improvement initiative was included, with reference to a shovel reliability review; a dipper trip reliability investigation; bucket related failures by type and frequency; root cause analysis of the reliability process; and additional actions taken. Last, the presentation provided a graph of the results of the improvement initiative and presented the key lessons learned. tabs., figs.

  16. A single-dose antihelminthic treatment does not influence immunogenicity of a meningococcal and a cholera vaccine in Gabonese school children.

    Science.gov (United States)

    Brückner, Sina; Agnandji, Selidji Todagbe; Elias, Johannes; Berberich, Stefan; Bache, Emmanuel; Fernandes, José; Loembe, Marguerite Massinga; Hass, Johanna; Lell, Bertrand; Mordmüller, Benjamin; Adegnika, Ayola Akim; Kremsner, Peter; Esen, Meral

    2016-10-17

    We recently described the effect of a single-dose antihelminthic treatment on vaccine immunogenicity to a seasonal influenza vaccine. Here we report the effect of antihelminthics on the immunogenicity of a meningococcal vaccine and a cholera vaccine in primary school children living in Lambaréné, Gabon. Since infection with helminths remains a major public health problem and the influence on cognitive and physical development as well as the immunomodulatory effects are well established, we investigated if a single-dose antihelminthic treatment prior to immunization positively influences antibody titers and vaccine-specific memory B-cells. In this placebo-controlled, double-blind trial the effect of a single-dose antihelminthic treatment prior to immunization with a meningococcal as well as with a cholera vaccine was investigated. Anti-meningococcal antibodies were assessed by serum bactericidal assay, cholera vaccine-specific antibody titers by Enzyme-linked Immunosorbent Assay (ELISA) at baseline (Day 0; vaccination), four weeks (Day 28) and 12weeks (Day 84) following vaccination. Meningococcal and cholera vaccine-specific memory B-cells were measured at Day 0 and 84 by vaccine-specific Enzyme-linked Immunospot (ELISpot) assay. The helminth burden of the participants was assessed four weeks before vaccination (Day -28) and at Day 84 by the Merthiolate-Iodine-Formaldehyde technique. Out of 280 screened school children, 96 received a meningococcal vaccine and 89 a cholera vaccine following allocation to either the single-dose antihelminthic treatment group or the placebo group. Bactericidal antibody titers increased following immunization with the meningococcal vaccine at Day 28 and Day 84 in 68 participants for serogroup A, and in 80 participants for serogroup C. The cholera vaccine titers increased in all participants with a peak at Day 28. The number of memory B-cells increased following vaccination compared to baseline. There was no statistically significant

  17. Software evolution and maintenance

    CERN Document Server

    Tripathy, Priyadarshi

    2014-01-01

    Software Evolution and Maintenance: A Practitioner's Approach is an accessible textbook for students and professionals, which collates the advances in software development and provides the most current models and techniques in maintenance.Explains two maintenance standards: IEEE/EIA 1219 and ISO/IEC14764Discusses several commercial reverse and domain engineering toolkitsSlides for instructors are available onlineInformation is based on the IEEE SWEBOK (Software Engineering Body of Knowledge)

  18. Status of fusion maintenance

    International Nuclear Information System (INIS)

    Fuller, G.M.

    1984-01-01

    Effective maintenance will be an essential ingredient in determining fusion system productivity. This level of productivity will result only after close attention is paid to the entire system as an entity and appropriate integration of the elements is made. The status of fusion maintenance is reviewed in the context of the entire system. While there are many challenging developmental tasks ahead in fusion maintenance, the required technologies are available in several high-technology industries, including nuclear fission

  19. Laboratory equipment maintenance contracts.

    Science.gov (United States)

    Boudreau, D A; Scheer, W D; Catrou, P G

    1985-12-01

    The increasing level of technical sophistication and complexity found in clinical laboratory instrumentation today more than ever demands careful attention to maintenance service needs. The time-worn caution for careful definition of requirements for acquisition of a system should also carry over to acquisition of maintenance service. Guidelines are presented for specifications of terms and conditions for maintenance service from the perspective of the laboratorian in the automated clinical laboratory.

  20. Interactive videodisc in maintenance

    International Nuclear Information System (INIS)

    Zwingelstein, G.; Nguyen Van Nghi, B.

    1986-01-01

    After a recall of the videodisc characteristics, this paper presents its utilization by Electricite de France in the framework of training and maintenance. The SICMA (Interactive Communication System in Maintenance) developed and tested by Electricte de France is presented as also its utilization. It has been tested on the sites of Dampierre and Paluel in the cases of training and maintenance (deconnexion of drive rods of control elements); the conclusions of this experimentation are finally given. 4 refs [fr

  1. Turbine maintenance and modernization

    Energy Technology Data Exchange (ETDEWEB)

    Unga, E. [Teollisuuden Voima Oy, Olkiluoto (Finland)

    1998-12-31

    The disturbance-free operation of the turbine plant plays an important role in reaching good production results. In the turbine maintenance of the Olkiluoto nuclear power plant the lifetime and efficiency of turbine components and the lifetime costs are taken into account in determining the turbine maintenance and modernization/improvement program. The turbine maintenance program and improvement/modernization measures taken in the plant units are described in this presentation. (orig.)

  2. Turbine maintenance and modernization

    Energy Technology Data Exchange (ETDEWEB)

    Unga, E [Teollisuuden Voima Oy, Olkiluoto (Finland)

    1999-12-31

    The disturbance-free operation of the turbine plant plays an important role in reaching good production results. In the turbine maintenance of the Olkiluoto nuclear power plant the lifetime and efficiency of turbine components and the lifetime costs are taken into account in determining the turbine maintenance and modernization/improvement program. The turbine maintenance program and improvement/modernization measures taken in the plant units are described in this presentation. (orig.)

  3. The influence of the dose of calcium bisglycinate on physicochemical properties, sensory analysis and texture profile of kefirs during 21 days of cold storage.

    Science.gov (United States)

    Pawlos, Małgorzata; Znamirowska, Agata; Szajnar, Katarzyna; Kalicka, Dorota

    2016-01-01

    In the process of enrichment of dairy products a priority element is the proper selection of compounds that are a mineral carrier. Calcium bisglycinate is better absorbed by the body than inorganic forms of calcium. Moreover, the lactic acid which is produced in kefir fermentation and the presence of lactose have also a positive effect on the improvement of absorption of calcium. The aim of the present study was to determine the influence of the applied dose of calcium in the form of calcium bisglycinate on the physicochemical and sensory properties and texture of kefirs during 21-day period of cold storage. Processed cow milk was enriched with 0, 5, 10, 15, 20, 25 and 30 mg of calcium (for 100 g of milk), repasteurized (72°C, 1 min), cooled down (26°C), inoculated with Commercial VITAL kefir culture (Danisco, Poland) and fermented for 16 hours (26°C). The assessment of the influence of addition   of calcium bisglycinate on acidity, syneresis, texture and sensory characteristics (1-9 points) of kefirs was conducted at four fixed dates (after 1 day, 7 days, 14 days and 21 days of storage). During successive weeks of cold storage in all experimental groups there was observed a tendency to decrease general acidity. On the 1st and 7th days of cold storage reduced whey leakage was observed in kefirs enriched with 25 mg and 30 mg Ca/100 g of milk. With increasing doses of enrichment with calcium both the hardness, adhesiveness and gumminess of kefirs decreased. The applied doses of calcium did not cause changes in the sensory characteristics such as colour and consistency of the fermented beverages. Calcium bisglycinate may be used to enrich kefirs with calcium even with 30 mg of calcium in 100 g of milk without the modification of the product's parameters.

  4. Industrial Maintenance Strategies

    International Nuclear Information System (INIS)

    Sajjad Akbar

    2006-01-01

    Industrial plants have become more complex due to technological advancement. This has made the task of maintenance more difficult. The maintenance costs in terms of resources and downtime loss are so high that maintenance function has become a critical factor in a plant's profitability. Industry should devote as much forethought to the management of maintenance function as to production. Maintenance has grown from an art to a precise, technical engineering science. Planning, organizing scheduling and control of maintenance using modern techniques pays dividends in the form of reduced costs and increased reliability. The magnitude and the dimension of maintenance have multiplied due to development in the engineering technologies. Production cost and capacities are directly affected by the breakdown time. Total operating cost including the maintenance cost plays an important role in replacement dimension. The integrated system approach would bring forth the desired results of high maintenance standards. The standards once achieved and sustained, would add to the reliability of the plan and relieve heavy stresses and strains on the engineering logistic support. (author)

  5. Analysis of maintenance strategies

    International Nuclear Information System (INIS)

    Laakso, K.; Simola, K.

    1998-01-01

    The main topics of the presentation include: (1) an analysis model and methods to evaluate maintenance action programs and the support decision to make changes in them and (2) to understand the maintenance strategies in a systems perspective as a basis for future developments. The subproject showed how systematic models for maintenance analysis and decision support, utilising computerised and statistical tool packages, can be taken into use for evaluation and optimisation of maintenance of active systems from the safety and economic point of view

  6. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  7. Army Maintenance System Transformation

    National Research Council Canada - National Science Library

    Gilbertson, Frank V

    2006-01-01

    .... Used in conjunction with pertinent historical data and developed with Army transformation goals in mind, General Systems thinking can provide the framework for guiding maintenance transformation...

  8. Dynamics of rectal balloon implant shrinkage in prostate VMAT. Influence on anorectal dose and late rectal complication risk

    Energy Technology Data Exchange (ETDEWEB)

    Vanneste, Ben G.L.; Wijk, Y. van; Lutgens, L.C.; Limbergen, E.J. van; Lambin, P. [Maastricht University Medical Center+, Department of Radiation Oncology (MAASTRO), GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Lin, E.N. van [Radiotherapy Bonn-Rhein-Sieg, Troisdorf (Germany); Beek, K. van de [Maastricht University Medical Center+, Department of Urology, Maastricht (Netherlands); Hoffmann, A.L. [Maastricht University Medical Center+, Department of Radiation Oncology (MAASTRO), GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Dresden (Germany); University Hospital Carl Gustav Carus, Technische Universitaet Dresden, Department of Radiotherapy, Dresden (Germany)

    2018-01-15

    To assess the effect of a shrinking rectal balloon implant (RBI) on the anorectal dose and complication risk during the course of moderately hypofractionated prostate radiotherapy. In 15 patients with localized prostate cancer, an RBI was implanted. A weekly kilovolt cone-beam computed tomography (CBCT) scan was acquired to measure the dynamics of RBI volume and prostate-rectum separation. The absolute anorectal volume encompassed by the 2 Gy equieffective 75 Gy isodose (V{sub 75Gy}) was recalculated as well as the mean anorectal dose. The increase in estimated risk of grade 2-3 late rectal bleeding (LRB) between the start and end of treatment was predicted using nomograms. The observed acute and late toxicities were evaluated. A significant shrinkage of RBI volumes was observed, with an average volume of 70.4% of baseline at the end of the treatment. Although the prostate-rectum separation significantly decreased over time, it remained at least 1 cm. No significant increase in V{sub 75Gy} of the anorectum was observed, except in one patient whose RBI had completely deflated in the third week of treatment. No correlation between mean anorectal dose and balloon deflation was found. The increase in predicted LRB risk was not significant, except in the one patient whose RBI completely deflated. The observed toxicities confirmed these findings. Despite significant decrease in RBI volume the high-dose rectal volume and the predicted LRB risk were unaffected due to a persistent spacing between the prostate and the anterior rectal wall. (orig.) [German] Beurteilung der Wirkung eines schrumpfenden rektalen Ballonimplantats (RBI) auf die anorektale Dosis und das Komplikationsrisiko im Verlauf einer maessig hypofraktionierten Strahlentherapie der Prostata. Ein RBI wurde 15 Patienten mit lokal begrenztem Prostatakarzinom implantiert. Zur Messung der Dynamik des RBI-Volumens und der Prostata-Rektum-Trennung wurde eine woechentliche Kilovolt-Cone-beam-Computertomographie (CBCT

  9. Radioprotective influence on mice DNA of biopolymer complexes from tinder Fomes Fomentarius under ionizing radiation in small doses

    Directory of Open Access Journals (Sweden)

    O. F. Seniuk

    2014-03-01

    Full Text Available The effects of similar doses of the values of common external irradiation (0,19 Gy/4hours and 0,24 Gy/6 months at single-strand DNA breaks and the level of the hydrogen bonds in this molecule in different cell types (lymphocytes, hepatocytes and splenocytes linear mice CC57W/mv are discussed. Mice were exposed to γ-fields produced by “hot” particles of emergency 4-th Chernobyl Unit containing the same radionuclides in the proportions. The possibility of leveling the radiation effects using complex biopolymers from Fomes fomentarius was shown. The ability of melanin-glucan complex to directly counteract the fragmentation of DNA in a model system with lambda phage this macromolecule oxidation products of benzidine and neutralize mutagenic effect in Salmonella typhimurium strains in the classical Ames test was studied.

  10. Radioprotective influence on mice DNA of biopolymer complexes from