WorldWideScience

Sample records for magnetization transfer ratio

  1. Magnetization transfer ratio relates to cognitive impairment in normal elderly

    Directory of Open Access Journals (Sweden)

    Stephan eSeiler

    2014-09-01

    Full Text Available Magnetization transfer imaging (MTI can detect microstructural brain tissue changes and may be helpful in determining age-related cerebral damage. We investigated the association between the magnetization transfer ratio (MTR in gray and white matter and cognitive functioning in 355 participants of the Austrian Stroke Prevention Family Study (ASPS-Fam aged 38 to 86 years. MTR maps were generated for the neocortex, deep gray matter structures, white matter hyperintensities, and normal appearing white matter. Adjusted mixed models determined whole brain and lobar cortical MTR to be directly and significantly related to performance on tests of memory, executive function and motor skills. There existed an almost linear dose-effect relationship. MTR of deep gray matter structures and normal appearing white matter correlated to executive functioning. All associations were independent of demographics, vascular risk factors, focal brain lesions and cortex volume.Further research is needed to understand the basis of this association at the tissue level, and to determine the role of MTR in predicting cognitive decline and dementia.

  2. Magnetization transfer on T2-weighted image : magnetization Transfer ratios in normal brain and cerebral lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Roh, Hong Gee; Suh, Chang Hae; Cho, Young Kook; Kim, Hyung Jin; Kim, Jin Hee; Kim, Sung Tae; Choi, Sung Kyu [Inha Univ. College of Medicine, Incheon (Korea, Republic of)

    1998-07-01

    To evaluate the magnetization transfer ratio(MTR) of various normal structures and pathologic lesions, as seen on magnetization transfer T2-weighted images (MT+T2WI). Materials and Methods : In ten normal volunteers, T2-weighted images without MT (MT-T2WI) and with MT(MT+T2WI) were obtained. Off-set pulses used in MT+T2WI were 400, 600, 1000, 1500, and 2000Hz. In 60 clinical cases infarction(n=10), brain tumors(n=5), traumatic hematomas(n=5), other hematomas(n=3) vascular malformation(n=2) white matter disease(n=2) normal(n=31) and others(n=2), both MT-T2WI and MT+T2WI images were obtained using an off-set pulse of 600 Hz. In all volunteers and patients, MTR in various normal brain parenchyma and abnormal areas was measured. Results : The MTRs of white and gray matter were 48% and 45% respectively at 400 Hz, 26% and 22% at 600Hz, 12% and 11% of 1000Hz, 10% and 9% 1500HZ, and 9% and 8% at 2000Hz of RF. The MTR of CSF was 43% at 400 Hz of off-resonance RF, while the contrast resolution of T2WI was poor. An off-resonance of 600Hz appeared to be the optimal frequency. In diseased areas,MTRs varied but were usually similar to or lower than those of brain parenchyma. Conclusion : The optimal off-resonance RF on MT+T2WI appears to be 600 Hz for relatively high MTR of brain parenchyma and low MTR of CSF,in which MTRs of white and gray matter were 26% and 22%, respectively, of 600Hz off-set pulse. The MTRs of cerebral lesions varied and further studies of various cerebral lesions are needed.

  3. Regional analysis of the magnetization transfer ratio of the brain in mild Alzheimer disease and amnestic mild cognitive impairment.

    Science.gov (United States)

    Mascalchi, M; Ginestroni, A; Bessi, V; Toschi, N; Padiglioni, S; Ciulli, S; Tessa, C; Giannelli, M; Bracco, L; Diciotti, S

    2013-01-01

    Manually drawn VOI-based analysis shows a decrease in magnetization transfer ratio in the hippocampus of patients with Alzheimer disease. We investigated with whole-brain voxelwise analysis the regional changes of the magnetization transfer ratio in patients with mild Alzheimer disease and patients with amnestic mild cognitive impairment. Twenty patients with mild Alzheimer disease, 27 patients with amnestic mild cognitive impairment, and 30 healthy elderly control subjects were examined with high-resolution T1WI and 3-mm-thick magnetization transfer images. Whole-brain voxelwise analysis of magnetization transfer ratio maps was performed by use of Statistical Parametric Mapping 8 software and was supplemented by the analysis of the magnetization transfer ratio in FreeSurfer parcellation-derived VOIs. Voxelwise analysis showed 2 clusters of significantly decreased magnetization transfer ratio in the left hippocampus and amygdala and in the left posterior mesial temporal cortex (fusiform gyrus) of patients with Alzheimer disease as compared with control subjects but no difference between patients with amnestic mild cognitive impairment and either patients with Alzheimer disease or control subjects. VOI analysis showed that the magnetization transfer ratio in the hippocampus and amygdala was significantly lower (bilaterally) in patients with Alzheimer disease when compared with control subjects (ANOVA with Bonferroni correction, at P ratio values in the hippocampus and amygdala in patients with amnestic mild cognitive impairment were between those of healthy control subjects and those of patients with mild Alzheimer disease. Support vector machine-based classification demonstrated improved classification performance after inclusion of magnetization transfer ratio-related features, especially between patients with Alzheimer disease versus healthy subjects. Bilateral but asymmetric decrease of magnetization transfer ratio reflecting microstructural changes of the

  4. Evaluation of magnetization transfer ratio in ascites and pelvic cystic masses

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Susumu [Nippon Medical School, Inba, Chiba (Japan). Chiba-Hokuso Hospital; Kato, Tomoyasu; Yamashita, Takashi [and others

    1997-12-01

    To investigate the feasibility of magnetization transfer contrast (MTC) in characterization of pelvic cystic masses and ascites, in vitro studies were performed. Cystic fluids were taken from operative specimens of ten ovarian cystic masses (five mucinous cystadenomas, one cystadenocarcinoma, two serous cystadenocarcinomas, two clear cell carcinomas) and three non-ovarian pelvic cysts (one paraovarian cyst, one pseudomyxoma peritonei, one pelvic abscess). Samples of ascitic flied were drawn by peritoneal puncture in twenty patients (thirteen with peritonitis carcinomatosa, five with liver dysfunction, two with renal dysfunction). Total protein content in ascitic fluids was measured. Magnetization transfer ratio (MTR) was calculated by the signal intensities under the gradient echo sequence with and without the application of off-resonance pulses. The relative signal intensities (RSI) relative to water in T{sub 1} and T{sub 2} weighted images were obtained using spin echo sequence. There was no correlation between histological type of pelvic mass and MTR and RSI. Good correlation (R{sup 2}=0.761) was obtained between MTR and protein content in ascitic fluids, whereas no correlation was noted between RSI and protein content in ascitic fluids. These results suggest that MTC is not useful in the characterization of pelvic masses but is applicable in the differentiation between exudative ascites and transudative ascites. (author)

  5. Atrophy and magnetization transfer ratio of the corpus callosum in patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Imon, Yukari; Hanyu, Haruo; Iwamoto, Toshihiko; Takasaki, Masaru; Abe, Kimihiko

    1998-01-01

    We compared atrophy and magnetization transfer ratio (MTR) in the corpus callosum in patients with Alzheimer's disease and age-matched normal subjects. Fifteen patients with Alzheimer's disease and fourteen normal subjects received MRI. The corpus callosum was divided into three parts (anterior, middle, and posterior portions) on midsagittal slice, and their areas on T2-weighted reversed images and MTR on magnetization transfer contrast images in each portion were measured. The area and MTR decreased significantly in the posterior portion in patients with Alzheimer's disease. In the anterior portion, MTR decreased significantly, but although the area showed no significant change. In the middle portion, the area and MTR showed no significant change. MTR and the area was correlated in each portion in patients with Alzheimer's disease. The score of Hasegawa dementia scale-revised (HDS-R) and the area of the middle, posterior and total of corpus callosum were significantly related. The score of HDS-R and MTR in the anterior portion of corpus callosum were significantly related. The present study revealed decreases in MTR in the anterior portion of the corpus callosum of patients with Alzheimer's disease although the area showed no significant change, and this change suggests the increase in free water and/or the decrease in bound water in tissues, probably due to demyelination and axonal degeneration. (author)

  6. Delineation of cortical pathology in multiple sclerosis using multi-surface magnetization transfer ratio imaging

    Directory of Open Access Journals (Sweden)

    David A. Rudko

    2016-01-01

    Full Text Available The purpose of our study was to evaluate the utility of measurements of cortical surface magnetization transfer ratio (csMTR on the inner, mid and outer cortical boundaries as clinically accessible biomarkers of cortical gray matter pathology in multiple sclerosis (MS. Twenty-five MS patients and 12 matched controls were recruited from the MS Clinic of the Montreal Neurological Institute. Anatomical and magnetization transfer ratio (MTR images were acquired using 3 Tesla MRI at baseline and two-year time-points. MTR maps were smoothed along meshes representing the inner, mid and outer neocortical boundaries. To evaluate csMTR reductions suggestive of sub-pial demyelination in MS patients, a mixed model analysis was carried out at both the individual vertex level and in anatomically parcellated brain regions. Our results demonstrate that focal areas of csMTR reduction are most prevalent along the outer cortical surface in the superior temporal and posterior cingulate cortices, as well as in the cuneus and precentral gyrus. Additionally, age regression analysis identified that reductions of csMTR in MS patients increase with age but appear to hit a plateau in the outer caudal anterior cingulate, as well as in the precentral and postcentral cortex. After correction for the naturally occurring gradient in cortical MTR, the difference in csMTR between the inner and outer cortex in focal areas in the brains of MS patients correlated with clinical disability. Overall, our findings support multi-surface analysis of csMTR as a sensitive marker of cortical sub-pial abnormality indicative of demyelination in MS patients.

  7. Deep gray matter demyelination detected by magnetization transfer ratio in the cuprizone model.

    Directory of Open Access Journals (Sweden)

    Sveinung Fjær

    Full Text Available In multiple sclerosis (MS, the correlation between lesion load on conventional magnetic resonance imaging (MRI and clinical disability is weak. This clinico-radiological paradox might partly be due to the low sensitivity of conventional MRI to detect gray matter demyelination. Magnetization transfer ratio (MTR has previously been shown to detect white matter demyelination in mice. In this study, we investigated whether MTR can detect gray matter demyelination in cuprizone exposed mice. A total of 54 female C57BL/6 mice were split into one control group ( and eight cuprizone exposed groups ([Formula: see text]. The mice were exposed to [Formula: see text] (w/w cuprizone for up to six weeks. MTR images were obtained at a 7 Tesla Bruker MR-scanner before cuprizone exposure, weekly for six weeks during cuprizone exposure, and once two weeks after termination of cuprizone exposure. Immunohistochemistry staining for myelin (anti-Proteolopid Protein and oligodendrocytes (anti-Neurite Outgrowth Inhibitor Protein A was obtained after each weekly scanning. Rates of MTR change and correlations between MTR values and histological findings were calculated in five brain regions. In the corpus callosum and the deep gray matter a significant rate of MTR value decrease was found, [Formula: see text] per week ([Formula: see text] and [Formula: see text] per week ([Formula: see text] respectively. The MTR values correlated to myelin loss as evaluated by immunohistochemistry (Corpus callosum: [Formula: see text]. Deep gray matter: [Formula: see text], but did not correlate to oligodendrocyte density. Significant results were not found in the cerebellum, the olfactory bulb or the cerebral cortex. This study shows that MTR can be used to detect demyelination in the deep gray matter, which is of particular interest for imaging of patients with MS, as deep gray matter demyelination is common in MS, and is not easily detected on conventional clinical MRI.

  8. Magnetization transfer ratio for the assessment of perianal fistula activity in Crohn's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pinson, C.; Dolores, M.; Cruypeninck, Y.; Koning, E.; Dacher, J.N.; Savoye-Collet, C. [Rouen University Hospital-Charles Nicolle, Department of Radiology, Rouen cedex (France); Savoye, G. [Rouen University Hospital-Charles Nicolle, Department of Gastroenterology, Rouen cedex (France)

    2017-01-15

    Assessment of perianal fistulas is important to guide management of Crohn's disease (CD). Our objectives were to analyze the feasibility of magnetization transfer (MT) imaging to assess fistulas and to evaluate its contribution in assessing disease activity. During 15 months, all patients referred for perianal fistulas in CD underwent 3T-MRI including diffusion, T2/T1-weighted gadolinium-enhanced sequences and MT sequences (one with an off-resonance saturation pulse of 800 and one with 1200 Hz). We collected Van Assche score, fistula activity signs by analyzing T2, diffusion and contrast enhancement. We calculated MT ratio (MTR) with a ROI in the largest fistula. Twenty-nine patients (mean 34.9 years, range 17-53) were included. Van Assche score was 11.7, range 4-21. In 22 patients, the fistula presented with a bright T2 and diffusion signal with contrast enhancement, and was characterized as active. Mean MTR was respectively 47.2 (range 12-68) and 34.3 (range 11-57) at 800 and 1200 Hz. MTR at 800 Hz was significantly lower in non-active (34, range 12-55) than in active fistulas (51, range 24-68) (p < 0.02). MTR is feasible for the assessment of fistulas in CD and in the future could be used to help identify active and non-active fistulas. (orig.)

  9. Does Magnetization Transfer Ratio (MTR) contribute to the diagnosis and differential diagnosis of the dementias?

    International Nuclear Information System (INIS)

    Hentschel, F.; Kreis, M.; Damian, M.; Krumm, B.

    2004-01-01

    Purpose: The magnetization transfer ratio (MTR) is a MR-based neuroimaging procedure aiming at the quantification of the structural integrity of brain tissue. Its contribution to the differential diagnosis of dementias was examined and discussed in relation to the pathogenesis of age-related dementias. Materials and Methods: Sixty-one patients from a memory clinic were diagnosed by general physical and neuropsychiatric examination, and underwent neuropsychologic testing and neuroimaging using MRI. Their clinical diagnoses were based on standard operational research criteria. Additionally, the MTR in 10 defined regions of interest (ROI) was determined. This investigation was performed using a T1-weighted SE sequence. Average MTR values were determined in the individual ROI and their combinations and correlated with the age gender, cognitive impairment and clinical diagnosis. Sensitivity, specificity, positive and negative predictive value were determined, as well as the rate of correct classifications. Results: For cognitive healthy subjects, the MRT values correlate only mildly, though significantly, with age in the hippocampus and with gender in the dorsal corpus callosum. In contrast, the MTR in the frontal white matter correlates strongly and highly significantly with cognitive impairment in patients with dementia. The differential diagnostic assignment of Alzheimer's disease versus vascular dementia by MTR provides a correct classification of approximately 50% to 70%. PPV for no dementia vs. vascular dementia or the NPV for vascular vs. Alzheimer's disease are considerably higher exceeding 80%. For no dementia vs. Alzheimer's disease, the NPV was over 90%. (orig.)

  10. T2 relaxation time analysis in patients with multiple sclerosis: correlation with magnetization transfer ratio

    International Nuclear Information System (INIS)

    Papanikolaou, Nickolas; Papadaki, Eufrosini; Karampekios, Spyros; Maris, Thomas; Prassopoulos, Panos; Gourtsoyiannis, Nicholas; Spilioti, Martha

    2004-01-01

    The aim of the current study was to perform T2 relaxation time measurements in multiple sclerosis (MS) patients and correlate them with magnetization transfer ratio (MTR) measurements, in order to investigate in more detail the various histopathological changes that occur in lesions and normal-appearing white matter (NAWM). A total number of 291 measurements of MTR and T2 relaxation times were performed in 13 MS patients and 10 age-matched healthy volunteers. Measurements concerned MS plaques (105), NAWM (80), and ''dirty'' white matter (DWM; 30), evenly divided between the MS patients, and normal white matter (NWM; 76) in the healthy volunteers. Biexponential T2 relaxation-time analysis was performed, and also possible linearity between MTR and mean T2 relaxation times was evaluated using linear regression analysis in all subgroups. Biexponential relaxation was more pronounced in ''black-hole'' lesions (16.6%) and homogeneous enhancing plaques (10%), whereas DWM, NAWM, and mildly hypointense lesions presented biexponential behavior with a lower frequency(6.6, 5, and 3.1%, respectively). Non-enhancing isointense lesions and normal white matter did not reveal any biexponentional behavior. Linear regression analysis between monoexponential T2 relaxation time and MTR measurements demonstrated excellent correlation for DWM(r=-0.78, p<0.0001), very good correlation for black-hole lesions(r=-0.71, p=0.002), good correlation for isointense lesions(r=-0.60, p=0.005), moderate correlation for mildly hypointense lesions(r=-0.34, p=0.007), and non-significant correlation for homogeneous enhancing plaques, NAWM, and NWM. Biexponential T2 relaxation-time behavior is seen in only very few lesions (mainly on plaques with high degree of demyelination and axonal loss). A strong correlation between MTR and monoexponential T2 values was found in regions where either inflammation or demyelination predominates; however, when both pathological conditions coexist, this linear

  11. Evaluation of magnetization transfer ratios for breast tissues and breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Fumio; Murai, Hiroshi; Takeuchi, Thouru; Iwase, Takuji; Miura, Shigeto; Mastushima, Shigeru; Oosaki, Hikaru [Aichi Cancer Center, Nagoya (Japan). Hospital; Kinosada, Yasuomi

    1997-03-01

    To determine MTRs for normal structures and benign diseases in the breast two-dimensional magnetization transfer imaging was performed in 62 patients and in 3 young female volunteers. With regard to the MTRs of measurements in the normal breast tissues, fat tissues which is close to simple cysts in MTRs show little transfer of longitudinal magnetization. MTRs of the muscles was 15.15{+-}6.22%, which exceeded those of breast parenchyma. The breast parenchyma didn`t show the change of MTR value due to the difference of patient age and due to variable amount of fat and fibrous tissues. Breast parenchyma in the two young volunteers clearly showed biphasic change of MTR values in accordance with the menstrual cycle; little transfer value was due to hydration in the postovulatory period and high transfer value was due to dehydration in the preovulatory period. In the remaining one volunteer during lactation period, mammary parenchyma shows sever decrease in MTR, because mammary gland is loaded with massive fluid, showing a very high signal intensity on First IR and T2-weighted images. MTR values of benign breast diseases including mastopathy, fibroadenoma and phyllodes tumor had no significant difference from those of the breast parenchyma and muscle. Non-invasive ductal carcinoma was equivalent to breast parenchyma in MTR. (K.H.)

  12. Assessment of the patellofemoral cartilage: Correlation of knee pain score with magnetic resonance cartilage grading and magnetization transfer ratio asymmetry of glycosaminoglycan chemical exchange saturation transfer.

    Science.gov (United States)

    Lee, Young Han; Yang, Jaemoon; Jeong, Ha-Kyu; Suh, Jin-Suck

    2017-01-01

    Biochemical imaging of glycosaminoglycan chemical exchange saturation transfer (gagCEST) could predict the depletion of glycosaminoglycans (GAG) in early osteoarthritis. The purpose of this study was to evaluate the relationship between the magnetization transfer ratio asymmetry (MTR asym ) of gagCEST images and visual analog scale (VAS) pain scores in the knee joint. This retrospective study was approved by the institutional review board. A phantom study was performed using hyaluronic acid to validate the MTR asym values of gagCEST images. Knee magnetic resonance (MR) images of 22 patients (male, 9; female, 13; mean age, 50.3years; age range; 25-79years) with knee pain were included in this study. The MR imaging (MRI) protocol involved standard knee MRI as well as gagCEST imaging, which allowed region-of-interest analyses of the patellar facet and femoral trochlea. The MTR asym at 1.0ppm was calculated at each region. The cartilages of the patellar facets and femoral trochlea were graded according to the Outerbridge classification system. Data regarding the VAS scores of knee pain were collected from the electronic medical records of the patients. Statistical analysis was performed using Spearman's correlation. The results of the phantom study revealed excellent correlation between the MTR asym values and the concentration of GAGs (r=0.961; p=0.003). The cartilage grades on the MR images showed significant negative correlation with the MTR asym values in the patellar facet and femoral trochlea (r=-0.460; p=0.031 and r=-0.543; p=0.009, respectively). The VAS pain scores showed significant negative correlation with the MTR asym values in the patellar facet and femoral trochlea (r=-0.435; p=0.043 and r=-0.671; p=0.001, respectively). The pain scores were associated with the morphological and biochemical changes in articular cartilages visualized on knee MR images. The biochemical changes, visualized in terms of the MTR asym values of the gagCEST images, exhibited

  13. Magnetization transfer ratio in the brain of preterm subjects: age-related changes during the first 2 years of life

    Energy Technology Data Exchange (ETDEWEB)

    Xydis, Vassilios; Astrakas, Loukas; Zikou, Anastasia; Argyropoulou, Maria I. [University of Ioannina, Department of Radiology, Medical School, Ioannina (Greece); Pantou, Kostandina; Andronikou, Styliani [Medical School University of Ioannina, Neonatology Clinic, Child Health Department, Ioannina (Greece)

    2006-01-01

    To study the progress of myelination in preterm-born subjects by measuring the MT ratio (MTR) from birth, up to 24 months of corrected age.One hundred twenty-five preterm subjects (64 males and 61 females of gestational age 33{+-}2.4 weeks with chronologic and corrected age of 9.3{+-}5.1 and 7.7{+-}5.1 months, respectively) with normal brain MR using classic sequences were further evaluated for MTR by using a three-dimensional gradient-echo sequence (TR=32/TE=8/flip angle=6 4 mm/2 mm overlapping sections) with and without magnetization transfer prepulse. The magnetization transfer ratio was calculated as: MTR=(SIo-SIm)/SIo x 100%, where SIm refers to signal intensity from an image acquired with a MT prepulse and SIo the signal intensity from the image acquired without a MT prepulse. MTR increased asymptotically in the genu (R{sup 2}=0.85) and splenium (R{sup 2}=0.85) of the corpus callosum, the white matter of the frontal lobe (R{sup 2}=0.91) and occipital lobe (R{sup 2}=0.82), thalamus (R{sup 2}=0.86), caudate nucleus (R{sup 2}=0.67) and putamen (R{sup 2}=0.71), reaching the 95% of the final value at the corrected age 18.7, 17.7, 15.6, 12.9, 10.4, 9.2 and 6.4 months, respectively. This study shows age-related changes of the brain MTR and provides data that may be useful to assess disturbances in the progress of myelination. (orig.)

  14. Effect of the ratio of radial gap to radius of the coils on the transmission efficiency of wireless power transfer via coupled magnetic resonances

    Science.gov (United States)

    Gao, Pengfei; Tian, Zijian; Wang, Xuqi; Wu, Jun; Gui, Weifeng

    2018-03-01

    Wireless power transfer (WPT) via coupled magnetic resonance is a promising technology to be applied in many fields. In general, there will be a radial gap in practical application, and some special application environments need to limit the radius of the coils. Therefore, in this paper, considering the comprehensive analysis of the radial gap and the radius of the coils, the concept of the ratio of radial gap to the radius of the coils was proposed. Based on the circuit theory, the formula between the ratio and transmission efficiency of WPT was deduced, and the effects of the ratio on the transmission efficiency were studied respectively at different axial distances. Simulation experiments were carried out and the results not only demonstrate the influence law of the ratio on transmission efficiency, but also validate the value of the ratio which the axial distance has the greatest effect on the transmission efficiency. Besides, the results shows the relationship between the effect of the ratio on the efficiency and the effect of the axial distance on the efficiency. The experimental results show that the theoretical analysis is correct, thus providing an useful theoretical reference for the design and further research on the wireless power transfer system in complicated environment.

  15. Effect of the ratio of radial gap to radius of the coils on the transmission efficiency of wireless power transfer via coupled magnetic resonances

    Directory of Open Access Journals (Sweden)

    Pengfei Gao

    2018-03-01

    Full Text Available Wireless power transfer (WPT via coupled magnetic resonance is a promising technology to be applied in many fields. In general, there will be a radial gap in practical application, and some special application environments need to limit the radius of the coils. Therefore, in this paper, considering the comprehensive analysis of the radial gap and the radius of the coils, the concept of the ratio of radial gap to the radius of the coils was proposed. Based on the circuit theory, the formula between the ratio and transmission efficiency of WPT was deduced, and the effects of the ratio on the transmission efficiency were studied respectively at different axial distances. Simulation experiments were carried out and the results not only demonstrate the influence law of the ratio on transmission efficiency, but also validate the value of the ratio which the axial distance has the greatest effect on the transmission efficiency. Besides, the results shows the relationship between the effect of the ratio on the efficiency and the effect of the axial distance on the efficiency. The experimental results show that the theoretical analysis is correct, thus providing an useful theoretical reference for the design and further research on the wireless power transfer system in complicated environment.

  16. Pool size ratio of the substantia nigra in Parkinson's disease derived from two different quantitative magnetization transfer approaches

    Energy Technology Data Exchange (ETDEWEB)

    Trujillo, Paula [Department of Neuroradiology, Fondazione IRCCS Ca' Granda - Ospedale Maggiore Policlinico, Milan, MI (Italy); Vanderbilt University Medical Center, Department of Neurology, Nashville, TN (United States); Summers, Paul E.; Costa, Antonella [Department of Neuroradiology, Fondazione IRCCS Ca' Granda - Ospedale Maggiore Policlinico, Milan, MI (Italy); Smith, Alex K. [University of Oxford, Centre for Functional Magnetic Resonance Imaging of the Brain (FMRIB), Nuffield Department of Clinical Neuroscience, Oxford (United Kingdom); Smith, Seth A. [Vanderbilt University Institute of Imaging Science, Nashville, TN (United States); Vanderbilt University, Department of Biomedical Engineering, Nashville, TN (United States); Mainardi, Luca T.; Cerutti, Sergio [Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, MI (Italy); Claassen, Daniel O. [Vanderbilt University Medical Center, Department of Neurology, Nashville, TN (United States)

    2017-12-15

    We sought to measure quantitative magnetization transfer (qMT) properties of the substantia nigra pars compacta (SNc) in patients with Parkinson's disease (PD) and healthy controls (HCs) using a full qMT analysis and determine whether a rapid single-point measurement yields equivalent results for pool size ratio (PSR). Sixteen different MT-prepared MRI scans were obtained at 3 T from 16 PD patients and eight HCs, along with B1, B0, and relaxation time maps. Maps of PSR, free and macromolecular pool transverse relaxation times (T{sub 2}{sup f}, T{sub 2}{sup m}) and rate of MT exchange between pools (k{sub mf}) were generated using a full qMT model. PSR maps were also generated using a single-point qMT model requiring just two MT-prepared images. qMT parameter values of the SNc, red nucleus, cerebral crus, and gray matter were compared between groups and methods. PSR of the SNc was the only qMT parameter to differ significantly between groups (p < 0.05). PSR measured via single-point analysis was less variable than with the full MT model, provided slightly better differentiation of PD patients from HCs (area under curve 0.77 vs. 0.75) with sensitivity of 0.75 and specificity of 0.87, and was better than transverse relaxation time in distinguishing PD patients from HCs (area under curve 0.71, sensitivity 0.87, and specificity 0.50). The increased PSR observed in the SNc of PD patients may provide a novel biomarker of PD, possibly associated with an increased macromolecular content. Single-point PSR mapping with reduced variability and shorter scan times relative to the full qMT model appears clinically feasible. (orig.)

  17. The application of T1 and T2 relaxation time and magnetization transfer ratios to the early diagnosis of patellar cartilage osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Weiwu; Qu, Nan; Lu, Zhihua; Yang, Shixun [Shanghai Jiaotong University, Department of Radiology, Shanghai (China)

    2009-11-15

    We compare the T1 and T2 relaxation times and magnetization transfer ratios (MTRs) of normal subjects and patients with osteoarthritis (OA) to evaluate the ability of these techniques to aid in the early diagnosis and treatment of OA. The knee joints in 11 normal volunteers and 40 patients with OA were prospectively evaluated using T1 relaxation times as measured using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC), T2 relaxation times (multiple spin-echo sequence, T2 mapping), and MTRs. The OA patients were further categorized into mild, moderate, and severe OA. The mean T1 relaxation times of the four groups (normal, mild OA, moderate OA, and severe OA) were: 487.3{+-}27.7, 458.0{+-}55.9, 405.9{+-}57.3, and 357.9{+-}36.7 respectively (p<0.001). The mean T2 relaxation times of the four groups were: 37.8{+-}3.3, 44.0{+-}8.5, 50.9{+-}9.5, and 57.4{+-}4.8 respectively (p<0.001). T1 relaxation time decreased and T2 relaxation time increased with worsening degeneration of patellar cartilage. The result of the covariance analysis showed that the covariate age had a significant influence on T2 relaxation time (p<0.001). No significant differences between the normal and OA groups using MTR were noted. T1 and T2 relaxation times are relatively sensitive to early degenerative changes in the patellar cartilage, whereas the MTR may have some limitations with regard to early detection of OA. In addition, The T1 and T2 relaxation times negatively correlate with each other, which is a novel finding. (orig.)

  18. Wireless power transfer magnetic couplers

    Science.gov (United States)

    Wu, Hunter; Gilchrist, Aaron; Sealy, Kylee

    2016-01-19

    A magnetic coupler is disclosed for wireless power transfer systems. A ferrimagnetic component is capable of guiding a magnetic field. A wire coil is wrapped around at least a portion of the ferrimagnetic component. A screen is capable of blocking leakage magnetic fields. The screen may be positioned to cover at least one side of the ferrimagnetic component and the coil. A distance across the screen may be at least six times an air gap distance between the ferrimagnetic component and a receiving magnetic coupler.

  19. Magnetic resonance for wireless power transfer

    OpenAIRE

    Hui, SYR

    2016-01-01

    Magnetic resonance has been a cornerstone of nonradiative wireless power transfer (WPT) since the late 19th century. However, some researchers have the misconception that magnetic resonance for WPT was developed recently. This article traces some early work of Tesla and other researchers related to the use of magnetic resonance in WPT. Included are some examples of magnetic resonance-based WPT projects conducted by researchers in the biomedical and power electronics communities over the last ...

  20. Transfer Entropy as a Log-Likelihood Ratio

    Science.gov (United States)

    Barnett, Lionel; Bossomaier, Terry

    2012-09-01

    Transfer entropy, an information-theoretic measure of time-directed information transfer between joint processes, has steadily gained popularity in the analysis of complex stochastic dynamics in diverse fields, including the neurosciences, ecology, climatology, and econometrics. We show that for a broad class of predictive models, the log-likelihood ratio test statistic for the null hypothesis of zero transfer entropy is a consistent estimator for the transfer entropy itself. For finite Markov chains, furthermore, no explicit model is required. In the general case, an asymptotic χ2 distribution is established for the transfer entropy estimator. The result generalizes the equivalence in the Gaussian case of transfer entropy and Granger causality, a statistical notion of causal influence based on prediction via vector autoregression, and establishes a fundamental connection between directed information transfer and causality in the Wiener-Granger sense.

  1. The magnetic fluid for heat transfer applications

    International Nuclear Information System (INIS)

    Nakatsuka, K.; Jeyadevan, B.; Neveu, S.; Koganezawa, H.

    2002-01-01

    Real-time visual observation of boiling water-based and ionic magnetic fluids (MFs) and heat transfer characteristics in heat pipe using ionic MF stabilized by citrate ions (JC-1) as working liquid are reported. Irrespective of the presence or absence of magnetic field water-based MF degraded during boiling. However, the degradation of JC-1 was avoided by heating the fluid in magnetic field. Furthermore, the heat transfer capacity of JC-1 heat pipe under applied magnetic field was enhanced over the no field case

  2. Magnetic field transfer device and method

    Science.gov (United States)

    Wipf, S.L.

    1990-02-13

    A magnetic field transfer device includes a pair of oppositely wound inner coils which each include at least one winding around an inner coil axis, and an outer coil which includes at least one winding around an outer coil axis. The windings may be formed of superconductors. The axes of the two inner coils are parallel and laterally spaced from each other so that the inner coils are positioned in side-by-side relation. The outer coil is outwardly positioned from the inner coils and rotatable relative to the inner coils about a rotational axis substantially perpendicular to the inner coil axes to generate a hypothetical surface which substantially encloses the inner coils. The outer coil rotates relative to the inner coils between a first position in which the outer coil axis is substantially parallel to the inner coil axes and the outer coil augments the magnetic field formed in one of the inner coils, and a second position 180[degree] from the first position, in which the augmented magnetic field is transferred into the other inner coil and reoriented 180[degree] from the original magnetic field. The magnetic field transfer device allows a magnetic field to be transferred between volumes with negligible work being required to rotate the outer coil with respect to the inner coils. 16 figs.

  3. Radius ratio effects on natural heat transfer in concentric annulus

    DEFF Research Database (Denmark)

    Alipour, M.; Hosseini, R.; Kolaei, Alireza Rezania

    2013-01-01

    This paper studies natural convection heat transfer in vertical and electrically heated annulus. The metallic cylinders mounted concentrically in a parallel tube. Measurements are carried out for four input electric powers and three radius ratios with an apparatus immersed in stagnant air...

  4. Quantitative Magnetization Transfer Imaging in Human Brain at 3 T via Selective Inversion Recovery

    OpenAIRE

    Dortch, Richard D.; Li, Ke; Gochberg, Daniel F.; Welch, E. Brian; Dula, Adrienne N.; Tamhane, Ashish A.; Gore, John C.; Smith, Seth A.

    2011-01-01

    Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons—including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools kmf. This study describes the first implementation of the selective inversion recovery quantitative magnetization transfer method on a clinical 3.0-T scanner in human brain in vivo. Selective inversion recovery data were acquired at 1...

  5. Heat transfer in a magnet C

    International Nuclear Information System (INIS)

    Sircilli Neto, F.; Passaro, A.; Borges, E.M.

    1991-01-01

    The cooling systems of nuclear reactors for spacial applications include direct current electromagnetic pumps, which are used to circulate the coolant fluid thru the reactor core. In this work, the transfer of the heat generated by the electrical current in a magnet C excitation coils, which is used in a prototype pump, was evaluated. Considering the processes of heat transfer by conduction, natural convection and radiation, the results of simulation with the codes HEATING5 and AUTHEATS indicate the utilization of the 180 sup(0)C thermal class conductor for a working Joule power of 4 10 sup(4) W/m sup(3) in each magnet coil. (author)

  6. Magnetization transfer MR of cerebrovascular disorders using calculated images

    Energy Technology Data Exchange (ETDEWEB)

    Enomoto, Kyoko; Watabe, Tsuneya; Amanuma, Makoto; Heshiki, Atsuko [Saitama Medical School, Moroyama, Saitama (Japan)

    1997-06-01

    This study applied a magnetization transfer contrast method to patients with cerebrovascular disorders. A 1.5 T superconducting MR unit was used, and magnetization transfer ratio (MTR) images were calculated by evaluating two paired images before and after off-resonance gradient echo pulse sequences. The normal white matter showed the highest MTRs, CSF the lowest, and gray matter, intermediate. Cerebral ischemic patients showed two patterns according to the chronological stage of the affected area. Lesions in the acute and subacute stages revealed higher transfer rates than those in the chronic stage. Patients with cerebral hemorrhage were divided into three groups: the hyperacute group showed a low transfer pattern; the acute group presented inhomogeneous high transfer rates; and the subacute group showed remarkably low transfer rates. In the acute and subacute ischemic stages, increased macromolecules caused higher MTRs than in the chronic stage. In hemorrhagic groups, low MTRs in subacute hemorrhage reflected the transfer of methemoglobin. High MTRs in acute hemorrhage with rich deoxyhemoglobin suggested increased fibrin, plasma, and serum components of macromolecules. The MTC method provided new chronological information on cerebral hemorrhage, adding to that provided by routine MR images. (author)

  7. Polarization transfer in relativistic magnetized plasmas

    Science.gov (United States)

    Heyvaerts, Jean; Pichon, Christophe; Prunet, Simon; Thiébaut, Jérôme

    2013-04-01

    The polarization transfer coefficients of a relativistic magnetized plasma are derived. These results apply to any momentum distribution function of the particles, isotropic or anisotropic. Particles interact with the radiation either in a non-resonant mode when the frequency of the radiation exceeds their characteristic synchrotron emission frequency or quasi-resonantly otherwise. These two classes of particles contribute differently to the polarization transfer coefficients. For a given frequency, this dichotomy corresponds to a regime change in the dependence of the transfer coefficients on the parameters of the particle's population, since these parameters control the relative weight of the contribution of each class of particles. Our results apply to either regimes as well as the intermediate one. The derivation of the transfer coefficients involves an exact expression of the conductivity tensor of the relativistic magnetized plasma that has not been used hitherto in this context. Suitable expansions valid at frequencies much larger than the cyclotron frequency allow us to analytically perform the summation over all resonances at high harmonics of the relativistic gyrofrequency. The transfer coefficients are represented in the form of two-variable integrals that can be conveniently computed for any set of parameters by using Olver's expansion of high-order Bessel functions. We particularize our results to a number of distribution functions, isotropic, thermal or power law, with different multipolar anisotropies of low order, or strongly beamed. Specifically, earlier exact results for thermal distributions are recovered. For isotropic distributions, the Faraday coefficients are expressed in the form of a one-variable quadrature over energy, for which we provide the kernels in the high-frequency limit and in the asymptotic low-frequency limit. An interpolation formula extending over the full energy range is proposed for these kernels. A similar reduction to a

  8. Wireless Energy Transfer Through Magnetic Reluctance Coupling

    International Nuclear Information System (INIS)

    Pillatsch, P

    2014-01-01

    Energy harvesting from human motion for body worn or implanted devices faces the problem of the wearer being still, e.g. while asleep. Especially for medical devices this can become an issue if a patient is bed-bound for prolonged periods of time and the internal battery of a harvesting system is not recharged. This article introduces a mechanism for wireless energy transfer based on a previously presented energy harvesting device. The internal rotor of the energy harvester is made of mild steel and can be actuated through a magnetic reluctance coupling to an external motor. The internal piezoelectric transducer is consequently actuated and generates electricity. This paper successfully demonstrates energy transfer over a distance of 16 mm in air and an achieved power output of 85 μW at 25 Hz. The device functional volume is 1.85 cm 3 . Furthermore, it was demonstrated that increasing the driving frequency beyond 25 Hz did not yield a further increase in power output. Future research will focus on improving the reluctance coupling, e.g. by investigating the use of multiple or stronger magnets, in order to increase transmission distance

  9. Blockage effects on viscous fluid flow and heat transfer past a magnetic obstacle in a duct

    International Nuclear Information System (INIS)

    Zhang Xi-Dong; Huang Hu-Lin

    2013-01-01

    The effect of lateral walls on fluid flow and heat transfer is investigated when a fluid passes a magnetic obstacle. The blockage ratio β that represents the ratio between the width of external magnet M y and the spanwise width L y is employed to depict the effect. The finite volume method (FVM) based on the PISO algorithm is applied for the blockage ratios of 0.2, 0.3, and 0.4. The results show that the value of Strouhal number St increases as the blockage ratio β increases, and for small β, the variation of St is very small when the interaction parameter and Reynolds number are increasing. Moreover, the cross-stream mixing induced by the magnetic obstacle can enhance the wall-heat transfer and the maximum value of the overall heat transfer increment is about 50.5%

  10. Optimum copper to superconductor ratio in cables for superconducting magnets at 1.9 K

    International Nuclear Information System (INIS)

    Wolf, R.

    1994-01-01

    In this paper the optimum copper to superconducting ratio is calculated to prevent quenching for superconducting cables used in accelerator magnets like the LHC dipoles, operating in superfluid helium at 1.9K. The duration of the perturbations leading to a quench are estimated from flux measurements made with pickup coils in the LHC dipole models. The optimum copper to superconducting ratio is then found by studying the minimum quench energy and the influence of the length and the duration or the perturbation and heat transfer to the surroundings. A comparison is made of the behavior at temperatures of 1.9 and 4.3 K

  11. Technology transfer considerations for the collider dipole magnet

    International Nuclear Information System (INIS)

    Goodzeit, C.; Fischer, R.

    1991-03-01

    The R ampersand D program at the national laboratories has resulted in significant advances in design and fabrication methods for the Collider Dipole Magnets. The status of the transfer of the technology developed by the laboratories is reviewed. The continuation of the technology transfer program is discussed with a description of: (1) the relation of technology transfer activities to collider dipole product development; (2) content of the program relating to key magnet performance issues; and (3) methods to implement the program. 5 refs

  12. Bimonthly assessment of magnetization transfer magnetic resonance imaging parameters in multiple sclerosis: a 14-month, multicentre, follow-up study

    NARCIS (Netherlands)

    Mesaros, S.; Rocca, M.A.; Sormani, M.P.; Valsasina, P.; Markowitz, C.; De Stefano, N.; Montalban, X.; Barkhof, F.; Ranjeva, J.P.; Sailer, M.; Kappos, L.; Comi, G.; Filippi, M.

    2010-01-01

    This study was performed to assess the temporal evolution of damage within lesions and the normal-appearing white matter, measured using frequent magnetization transfer (MT) MRI, in relapsing-remitting multiple sclerosis (RRMS). The relationship of MT ratio (MTR) changes with measures of lesion

  13. Magnetically-charged black branes and viscosity/entropy ratios

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hai-Shan [Institute for Advanced Physics & Mathematics,Zhejiang University of Technology, Hangzhou 310023 (China); George P. & Cynthia Woods Mitchell Institute for Fundamental Physics and Astronomy,Texas A& M University, College Station, TX 77843 (United States); Lü, H. [Department of Physics, Beijing Normal University,Beijing 100875 (China); Pope, C.N. [George P. & Cynthia Woods Mitchell Institute for Fundamental Physics and Astronomy,Texas A& M University, College Station, TX 77843 (United States); DAMTP, Centre for Mathematical Sciences,Cambridge University, Wilberforce Road, Cambridge CB3 OWA (United Kingdom)

    2016-12-19

    We consider asymptotically-AdS n-dimensional black brane solutions in a theory of gravity coupled to a set of Np-form field strengths, in which the field strengths carry magnetic charges. For appropriately chosen charges, the metrics are isotropic in the (n−2) transverse directions. However, in general the field strength configurations break the full Euclidean symmetry of the (n−2)-dimensional transverse space, and the shear viscosity tensor in the dual theory is no longer isotropic. We study the linearised equations for transverse traceless metric perturbations in these backgrounds, and by employing the Kubo formula we obtain expressions for the ratios η/S of the shear viscosity components divided by the entropy density. We find that the KSS bound on the ratios η/S is generally violated in these solutions. We also extend the discussion by including a dilatonic scalar field in the theory, leading to solutions that are asymptotically Lifshitz with hyperscaling violation.

  14. Magnetic nanofluid properties as the heat transfer enhancement agent

    Directory of Open Access Journals (Sweden)

    Roszko Aleksandra

    2016-01-01

    Full Text Available The main purpose of this paper was to investigate an influence of various parameters on the heat transfer processes with strong magnetic field utilization. Two positions of experimental enclosure in magnetic environment, two methods of preparation and three different concentrations of nanoparticles (0.0112, 0.056 and 0.112 vol.% were taken into account together with the magnetic field strength. Analysed nanofluids consisted of distilled water (diamagnetic and Cu/CuO particles (paramagnetic of 40–60 nm size. The nanofluids components had different magnetic properties what caused complex interaction of forces’ system. The heat transfer data and fluid flow structure demonstrated the influence of magnetic field on the convective phenomena. The most visible consequence of magnetic field application was the heat transfer enhancement and flow reorganization under applied conditions.

  15. B1 -sensitivity analysis of quantitative magnetization transfer imaging.

    Science.gov (United States)

    Boudreau, Mathieu; Stikov, Nikola; Pike, G Bruce

    2018-01-01

    To evaluate the sensitivity of quantitative magnetization transfer (qMT) fitted parameters to B 1 inaccuracies, focusing on the difference between two categories of T 1 mapping techniques: B 1 -independent and B 1 -dependent. The B 1 -sensitivity of qMT was investigated and compared using two T 1 measurement methods: inversion recovery (IR) (B 1 -independent) and variable flip angle (VFA), B 1 -dependent). The study was separated into four stages: 1) numerical simulations, 2) sensitivity analysis of the Z-spectra, 3) healthy subjects at 3T, and 4) comparison using three different B 1 imaging techniques. For typical B 1 variations in the brain at 3T (±30%), the simulations resulted in errors of the pool-size ratio (F) ranging from -3% to 7% for VFA, and -40% to > 100% for IR, agreeing with the Z-spectra sensitivity analysis. In healthy subjects, pooled whole-brain Pearson correlation coefficients for F (comparing measured double angle and nominal flip angle B 1 maps) were ρ = 0.97/0.81 for VFA/IR. This work describes the B 1 -sensitivity characteristics of qMT, demonstrating that it varies substantially on the B 1 -dependency of the T 1 mapping method. Particularly, the pool-size ratio is more robust against B 1 inaccuracies if VFA T 1 mapping is used, so much so that B 1 mapping could be omitted without substantially biasing F. Magn Reson Med 79:276-285, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Pleiotropic functions of magnetic nanoparticles for ex vivo gene transfer.

    Science.gov (United States)

    Kami, Daisuke; Kitani, Tomoya; Kishida, Tsunao; Mazda, Osam; Toyoda, Masashi; Tomitaka, Asahi; Ota, Satoshi; Ishii, Ryuga; Takemura, Yasushi; Watanabe, Masatoshi; Umezawa, Akihiro; Gojo, Satoshi

    2014-08-01

    Gene transfer technique has various applications, ranging from cellular biology to medical treatments for diseases. Although nonviral vectors, such as episomal vectors, have been developed, it is necessary to improve their gene transfer efficacy. Therefore, we attempted to develop a highly efficient gene delivery system combining an episomal vector with magnetic nanoparticles (MNPs). In comparison with the conventional method using transfection reagents, polyethylenimine-coated MNPs introduced episomal vectors more efficiently under a magnetic field and could express the gene in mammalian cells with higher efficiency and for longer periods. This novel in vitro separation method of gene-introduced cells utilizing the magnetic property of MNPs significantly facilitated the separation of cells of interest. Transplanted cells in vivo were detected using magnetic resonance. These results suggest that MNPs play multifunctional roles in ex vivo gene transfer, such as improvement of gene transfer efficacy, separation of cells, and detection of transplanted cells. This study convincingly demonstrates enhanced efficiency of gene transfer via magnetic nanoparticles. The method also enables magnetic sorting of cells positive for the transferred gene, and in vivo monitoring of the process with MRI. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Energy transfers in dynamos with small magnetic Prandtl numbers

    KAUST Repository

    Kumar, Rohit

    2015-06-25

    We perform numerical simulation of dynamo with magnetic Prandtl number Pm = 0.2 on 10243 grid, and compute the energy fluxes and the shell-to-shell energy transfers. These computations indicate that the magnetic energy growth takes place mainly due to the energy transfers from large-scale velocity field to large-scale magnetic field and that the magnetic energy flux is forward. The steady-state magnetic energy is much smaller than the kinetic energy, rather than equipartition; this is because the magnetic Reynolds number is near the dynamo transition regime. We also contrast our results with those for dynamo with Pm = 20 and decaying dynamo. © 2015 Taylor & Francis.

  18. Energy transfers in dynamos with small magnetic Prandtl numbers

    KAUST Repository

    Kumar, Rohit; Verma, Mahendra K.; Samtaney, Ravi

    2015-01-01

    We perform numerical simulation of dynamo with magnetic Prandtl number Pm = 0.2 on 10243 grid, and compute the energy fluxes and the shell-to-shell energy transfers. These computations indicate that the magnetic energy growth takes place mainly due

  19. SU-E-T-227: Could the Alpha/Beta Ratio Change in a Strong Magnetic Field?

    Energy Technology Data Exchange (ETDEWEB)

    Pang, G [Odette Cancer Centre, 2075 Bayview Avenue, Toronto M4N 3M5, Canada and Sunnybrook Research Institute and Departments of Radiation Oncology and Medical Biophysics, University of Toronto, Toronto (Canada)

    2015-06-15

    Purpose: Magnetic resonance imaging (MRI) is being integrated into radiotherapy delivery for MRI-guided radiotherapy. The presence of a strong magnetic field from a MRI machine during radiotherapy delivery presents a new challenge since the trajectories of electrons liberated by ionizing radiation in patients are strongly dependent on the applied magnetic field. The purpose of this work is to explore the potential effect of a strong magnetic field on the α/β ratio, an important radiobiological parameter in radiotherapy. Methods: Based on the theory of dual radiation action, the α/β ratio can be expressed by an integral of the product of two microdosimetry quantities γ(x) and t(x), where γ(x) is the probability that two energy transfers, a distance x apart, results in a lesion, and t(x) is the proximity function, which is the energy-weighted point-pair distribution of distances between energy transfer points in a track. The quantity t(x) depends on the applied magnetic field. An analytical approach has been used to derive a formula that can be used to calculate the α/β ratio in an extremely strong magnetic field. Results: The α/β ratio has been evaluated in the special case when the applied magnetic field approaches infinity, which gives the upper limit of the potential change of the α/β ratio due to the presence of a strong magnetic field. For V79 Chinese hamster cells it has been shown that the α/β ratio could be increased by 2.90 times for Pd-103, 2.97 times for I-125 and about 2.3 times for Co-60 sources when the applied magnetic field approaches infinity. Conclusion: It has been shown theoretically that the α/β ratio can change in a strong magnetic field, and there could be up to a nearly three-fold increase in the α/β ratio, depending on the strength of the applied magnetic field, the cell type and the radiation used.

  20. Dynamics of magnetization in ferromagnet with spin-transfer torque

    Science.gov (United States)

    Li, Zai-Dong; He, Peng-Bin; Liu, Wu-Ming

    2014-11-01

    We review our recent works on dynamics of magnetization in ferromagnet with spin-transfer torque. Driven by constant spin-polarized current, the spin-transfer torque counteracts both the precession driven by the effective field and the Gilbert damping term different from the common understanding. When the spin current exceeds the critical value, the conjunctive action of Gilbert damping and spin-transfer torque leads naturally the novel screw-pitch effect characterized by the temporal oscillation of domain wall velocity and width. Driven by space- and time-dependent spin-polarized current and magnetic field, we expatiate the formation of domain wall velocity in ferromagnetic nanowire. We discuss the properties of dynamic magnetic soliton in uniaxial anisotropic ferromagnetic nanowire driven by spin-transfer torque, and analyze the modulation instability and dark soliton on the spin wave background, which shows the characteristic breather behavior of the soliton as it propagates along the ferromagnetic nanowire. With stronger breather character, we get the novel magnetic rogue wave and clarify its formation mechanism. The generation of magnetic rogue wave mainly arises from the accumulation of energy and magnons toward to its central part. We also observe that the spin-polarized current can control the exchange rate of magnons between the envelope soliton and the background, and the critical current condition is obtained analytically. At last, we have theoretically investigated the current-excited and frequency-adjusted ferromagnetic resonance in magnetic trilayers. A particular case of the perpendicular analyzer reveals that the ferromagnetic resonance curves, including the resonant location and the resonant linewidth, can be adjusted by changing the pinned magnetization direction and the direct current. Under the control of the current and external magnetic field, several magnetic states, such as quasi-parallel and quasi-antiparallel stable states, out

  1. Effective Giromagnetic Ratios in Artifical Nuclear Magnetization Pumping of the Noble Gases Mix

    Directory of Open Access Journals (Sweden)

    Popov E.N.

    2015-01-01

    Full Text Available Dynamic of the nuclear magnetization of the two noble gases mix was studied in this research. Nuclear magnetization pumped along the induction of external magnetic field. Vector of nuclear magnetization is given a tilt by the week rotational magnetic field, which makes NMR for noble gases. Interaction between the nuclear magnetic moments of the different noble gases adducted to shifts at the frequency of nuclear moments precession in external magnetic field. Effective gyromagnetic ratios of the nuclear of noble gases is defined and it different from the tabulated value. There is theoretical calculation of effective gyromagnetic ratios in this research.

  2. Amide Proton Transfer (APT) MR imaging and Magnetization Transfer (MT) MR imaging of pediatric brain development

    International Nuclear Information System (INIS)

    Zhang, Hong; Kang, Huiying; Peng, Yun; Zhao, Xuna; Jiang, Shanshan; Zhang, Yi; Zhou, Jinyuan

    2016-01-01

    To quantify the brain maturation process during childhood using combined amide proton transfer (APT) and conventional magnetization transfer (MT) imaging at 3 Tesla. Eighty-two neurodevelopmentally normal children (44 males and 38 females; age range, 2-190 months) were imaged using an APT/MT imaging protocol with multiple saturation frequency offsets. The APT-weighted (APTW) and MT ratio (MTR) signals were quantitatively analyzed in multiple brain areas. Age-related changes in MTR and APTW were evaluated with a non-linear regression analysis. The APTW signals followed a decreasing exponential curve with age in all brain regions measured (R"2 = 0.7-0.8 for the corpus callosum, frontal and occipital white matter, and centrum semiovale). The most significant changes appeared within the first year. At maturation, larger decreases in APTW and lower APTW values were found in the white matter. On the contrary, the MTR signals followed an increasing exponential curve with age in the same brain regions measured, with the most significant changes appearing within the initial 2 years. There was an inverse correlation between the MTR and APTW signal intensities during brain maturation. Together with MT imaging, protein-based APT imaging can provide additional information in assessing brain myelination in the paediatric population. (orig.)

  3. Amide Proton Transfer (APT) MR imaging and Magnetization Transfer (MT) MR imaging of pediatric brain development

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hong; Kang, Huiying; Peng, Yun [Beijing Children' s Hospital, Capital Medical University, Imaging Center, Department of Radiology, Beijing (China); Zhao, Xuna [Philips Healthcare, Beijing (China); Jiang, Shanshan; Zhang, Yi; Zhou, Jinyuan [Johns Hopkins University, Division of MR Research, Department of Radiology, Baltimore, MD (United States)

    2016-10-15

    To quantify the brain maturation process during childhood using combined amide proton transfer (APT) and conventional magnetization transfer (MT) imaging at 3 Tesla. Eighty-two neurodevelopmentally normal children (44 males and 38 females; age range, 2-190 months) were imaged using an APT/MT imaging protocol with multiple saturation frequency offsets. The APT-weighted (APTW) and MT ratio (MTR) signals were quantitatively analyzed in multiple brain areas. Age-related changes in MTR and APTW were evaluated with a non-linear regression analysis. The APTW signals followed a decreasing exponential curve with age in all brain regions measured (R{sup 2} = 0.7-0.8 for the corpus callosum, frontal and occipital white matter, and centrum semiovale). The most significant changes appeared within the first year. At maturation, larger decreases in APTW and lower APTW values were found in the white matter. On the contrary, the MTR signals followed an increasing exponential curve with age in the same brain regions measured, with the most significant changes appearing within the initial 2 years. There was an inverse correlation between the MTR and APTW signal intensities during brain maturation. Together with MT imaging, protein-based APT imaging can provide additional information in assessing brain myelination in the paediatric population. (orig.)

  4. A chopper circuit for energy transfer between superconducting magnets

    International Nuclear Information System (INIS)

    Onishi, Toshitada; Tateishi, Hiroshi; Takeda, Masatoshi; Matsuura, Toshiaki; Nakatani, Toshio.

    1986-01-01

    It has been suggested that superconducting magnets could provide a medium for storing energy and supplying the large energy pulses needed by experimental nuclear-fusion equipment and similar loads. Based on this concept, tests on energy transfer between superconducting magnets are currently being conducted at the Agency of Industrial Science and Technology's Electrotechnical Laboratory. Mitsubishi Electric has pioneered the world's first chopper circuit for this application. The circuit has the advantages of being simple and permitting high-speed, bipolar energy transfer. The article describes this circuit and its testing. (author)

  5. Accurate magnetic field calculations for contactless energy transfer coils

    OpenAIRE

    Sonntag, C.L.W.; Spree, M.; Lomonova, E.A.; Duarte, J.L.; Vandenput, A.J.A.

    2007-01-01

    In this paper, a method for estimating the magnetic field intensity from hexagon spiral windings commonly found in contactless energy transfer applications is presented. The hexagonal structures are modeled in a magneto-static environment using Biot-Savart current stick vectors. The accuracy of the models are evaluated by mapping the current sticks and the hexagon spiral winding tracks to a local twodimensional plane, and comparing their two-dimensional magnetic field intensities. The accurac...

  6. Magnetization transfer analysis of cartilage repair tissue: a preliminary study

    International Nuclear Information System (INIS)

    Palmieri, F.; Keyzer, F. de; Maes, F.; Breuseghem, I. van

    2006-01-01

    To evaluate the magnetization transfer ratio (MTR) after two different cartilage repair procedures, and to compare these data with the MTR of normal cartilage. Twenty-seven patients with a proven cartilage defect were recruited: 13 were treated with autologous chondrocyte implantation (ACI) and 14 were treated with the microfracture technique (MFR). All patients underwent MRI examinations with MT-sequences before the surgical treatment, after 12 months (26 patients) and after 24 months (11 patients). Eleven patients received a complete follow-up study at all three time points (five of the ACI group and six of the MFR group). All images were transferred to a workstation to calculate MTR images. For every MT image set, different ROIs were delineated by two radiologists. Means were calculated per ROI type in the different time frames and in both groups of cartilage repair. The data were analyzed with unpaired t- and ANOVA tests, and by calculating Pearson's correlation coefficient. No significant differences were found in the MTR of fatty bone marrow, muscle and normal cartilage in the different time frames. There was a significant but small difference between the MTR of normal cartilage and the cartilage repair area after 12 months for both procedures. After 24 months, the MTR of ACI repaired cartilage (0.31±0.07) was not significantly different from normal cartilage MTR (0.34±0.05). The MTR of MFR repaired cartilage (0.28±0.02), still showed a significant difference from normal cartilage. The differences between damaged and repaired cartilage MTR are too small to enable MT-imaging to be a useful tool for postoperative follow-up of cartilage repair procedures. There is, however, an evolution towards normal MTR-values in the cartilage repair tissue (especially after ACI repair). (orig.)

  7. Energy transfer from a superconducting magnet to an inductive load

    International Nuclear Information System (INIS)

    Onishi, Toshitada; Miura, Akinori.

    1977-01-01

    Experiments on energy transfer between two superconducting magnets have been carried out using an inductive energy transfer system similar to the flying capacitor system developed at the Karlsruhe Institute. In the present system the capacitor is grounded and diodes are used instead of thyristors, and a fraction of stored energy is transferred to the capacitor only when the relay connected in parallel to the magnet is switched off. The capacitor is expected to have no constraint in size, while in the flying capacitor system the capacitor is required to exceed a threshold size. Consequently it is possible to shorten the transfer time to some extent in comparison with the one in the flying capacitor system. Transfer experiments have been carried out using a storage magnet with inductance of 1.2H and a load of 0.41H. The capacitance is 200μF. It is possible to transfer 80.1% of the stored energy of 221 J into the load in less than about 0.35 seconds. (auth.)

  8. Neutron scattering investigation of magnetic excitations at high energy transfers

    International Nuclear Information System (INIS)

    Loong, C.K.

    1984-01-01

    With the advance of pulsed spallation neutron sources, neutron scattering investigation of elementary excitations in magnetic materials can now be extended to energies up to several hundreds of MeV. We have measured, using chopper spectrometers and time-of-flight techniques, the magnetic response functions of a series of d and f transition metals and compounds over a wide range of energy and momentum transfer. In PrO 2 , UO 2 , BaPrO 3 and CeB 6 we observed crystal-field transitions between the magnetic ground state and the excited levels in the energy range from 40 to 260 MeV. In materials exhibiting spin-fluctuation or mixed-valent character such as Ce 74 Th 26 , on the other hand, no sharp crystal-field lines but a broadened quasielastic magnetic peak was observed. The line width of the quasielastic component is thought to be connected to the spin-fluctuation energy of the 4f electrons. The significance of the neutron scattering results in relation to the ground state level structure of the magnetic ions and the spin-dynamics of the f electrons is discussed. Recently, in a study of the spin-wave excitations in itinerant magnetic systems, we have extended the spin-wave measurements in ferromagnetic iron up to about 160 MeV. Neutron scattering data at high energy transfers are of particular interest because they provide direct comparison with recent theories of itinerant magnetism. 26 references, 7 figures

  9. Accurate magnetic field calculations for contactless energy transfer coils

    NARCIS (Netherlands)

    Sonntag, C.L.W.; Spree, M.; Lomonova, E.A.; Duarte, J.L.; Vandenput, A.J.A.

    2007-01-01

    In this paper, a method for estimating the magnetic field intensity from hexagon spiral windings commonly found in contactless energy transfer applications is presented. The hexagonal structures are modeled in a magneto-static environment using Biot-Savart current stick vectors. The accuracy of the

  10. Theory of radiative transfer in a strong magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, S [Ibaraki Univ., Mito (Japan). Dept. of Physics

    1975-07-01

    A theory is presented of the radiative transfer in a magnetized plasma with the opacity determined by the Thomson scattering. The Thomson cross section in the magnetic field is highly anisotropic and polarization-dependent. In order to cope with this situation, it is found useful to deal directly with the scattering amplitude (2x2 matrix in the polarization vector space) rather than the intensity. In this way it is possible to take into account the coherent superposition of the forward multiple-scattering amplitudes as a photon propagates. The equation of transfer is established accordingly and approximate solutions are found in the limits of small and large optical thickness. The latter solution is used to find the intensity and the polarization of thermal X-rays from a magnetic dipole star. The concept of mean free path is discussed and also it is shown that the Faraday rotation naturally comes about as a result of the multiple forward scattering.

  11. Accurate computation of transfer maps from magnetic field data

    International Nuclear Information System (INIS)

    Venturini, Marco; Dragt, Alex J.

    1999-01-01

    Consider an arbitrary beamline magnet. Suppose one component (for example, the radial component) of the magnetic field is known on the surface of some imaginary cylinder coaxial to and contained within the magnet aperture. This information can be obtained either by direct measurement or by computation with the aid of some 3D electromagnetic code. Alternatively, suppose that the field harmonics have been measured by using a spinning coil. We describe how this information can be used to compute the exact transfer map for the beamline element. This transfer map takes into account all effects of real beamline elements including fringe-field, pseudo-multipole, and real multipole error effects. The method we describe automatically takes into account the smoothing properties of the Laplace-Green function. Consequently, it is robust against both measurement and electromagnetic code errors. As an illustration we apply the method to the field analysis of high-gradient interaction region quadrupoles in the Large Hadron Collider (LHC)

  12. Statistical analysis of the ratio of electric and magnetic fields in random fields generators

    NARCIS (Netherlands)

    Serra, R.; Nijenhuis, J.

    2013-01-01

    In this paper we present statistical models of the ratio of random electric and magnetic fields in mode-stirred reverberation chambers. This ratio is based on the electric and magnetic field statistics derived for ideal reverberation conditions. It provides a further performance indicator for

  13. Magnetic resonance imaging findings after rectus femoris transfer surgery

    International Nuclear Information System (INIS)

    Gold, Garry E.; Asakawa, Deanna S.; Blemker, Silvia S.; Delp, Scott L.

    2004-01-01

    We describe the magnetic resonance (MR) imaging appearance of the knee flexor and extensor tendons after bilateral rectus femoris transfer and hamstring lengthening surgery in five patients (10 limbs) with cerebral palsy. Three-dimensional models of the path of the transferred tendon were constructed in all cases. MR images of the transferred and lengthened tendons were examined and compared with images from ten non-surgical subjects. The models showed that the path of the transferred rectus femoris tendon had a marked angular deviation near the transfer site in all cases. MR imaging demonstrated irregular areas of low signal intensity near the transferred rectus femoris and around the hamstrings in all subjects. Eight of the ten post-surgical limbs showed evidence of fluid near or around the transferred or lengthened tendons. This was not observed in the non-surgical subjects. Thus, MR imaging of patients with cerebral palsy after rectus femoris transfer and hamstring-lengthening surgery shows evidence of signal intensity and contour changes, even several years after surgery. (orig.)

  14. Magnetic MIMO Signal Processing and Optimization for Wireless Power Transfer

    Science.gov (United States)

    Yang, Gang; Moghadam, Mohammad R. Vedady; Zhang, Rui

    2017-06-01

    In magnetic resonant coupling (MRC) enabled multiple-input multiple-output (MIMO) wireless power transfer (WPT) systems, multiple transmitters (TXs) each with one single coil are used to enhance the efficiency of simultaneous power transfer to multiple single-coil receivers (RXs) by constructively combining their induced magnetic fields at the RXs, a technique termed "magnetic beamforming". In this paper, we study the optimal magnetic beamforming design in a multi-user MIMO MRC-WPT system. We introduce the multi-user power region that constitutes all the achievable power tuples for all RXs, subject to the given total power constraint over all TXs as well as their individual peak voltage and current constraints. We characterize each boundary point of the power region by maximizing the sum-power deliverable to all RXs subject to their minimum harvested power constraints. For the special case without the TX peak voltage and current constraints, we derive the optimal TX current allocation for the single-RX setup in closed-form as well as that for the multi-RX setup. In general, the problem is a non-convex quadratically constrained quadratic programming (QCQP), which is difficult to solve. For the case of one single RX, we show that the semidefinite relaxation (SDR) of the problem is tight. For the general case with multiple RXs, based on SDR we obtain two approximate solutions by applying time-sharing and randomization, respectively. Moreover, for practical implementation of magnetic beamforming, we propose a novel signal processing method to estimate the magnetic MIMO channel due to the mutual inductances between TXs and RXs. Numerical results show that our proposed magnetic channel estimation and adaptive beamforming schemes are practically effective, and can significantly improve the power transfer efficiency and multi-user performance trade-off in MIMO MRC-WPT systems.

  15. Magnetic Resonance Signal Intensity Ratio Measurement Before Uterine Artery Embolization

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Ravn, Pernille; Green, Anders

    2017-01-01

    , 52 patients were included in this prospective study. The SI ratio before UFE was calculated using circular region of interests placed on the dominant fibroid and the iliac muscle. The SI fibroid-to-iliac muscle ratio was calculated as SI of the dominant fibroid/SI of the iliac muscle on T1-, T2......-, and T1 post-contrast-weighted sequences. The dominant fibroid volume was measured and analyzed before and after UFE. RESULTS: In all, 46 patients who completed the three-month follow-up MRI were available for analysis. The correlation between SI fibroid-to-muscle ratio at the T2-weighted sequence...... positive correlation (r = 0.439, p T2-weighted sequence. The area under curve (AUC) for SI fibroid-to-muscle ratio on T2-weighted sequence was 0.776. For the other parameters, the AUC values were 0.512, 0.671, and 0.578, respectively. CONCLUSION: SI...

  16. Studies on MHD pressure drop and heat transfer of helium-lithium annular-mist flow in a transverse magnetic field

    International Nuclear Information System (INIS)

    Inoue, Akira; Aritomi, Masanori; Takahashi, Minoru; Matsuzaki, Mitsuo; Narita, Yoshihito; Yano, Toshikazu.

    1987-01-01

    Pressure drop and heat transfer coefficient of helium-lithium annular-mist flow in a rectangular duct were investigated experimentally under a transverse magnetic field at system pressure of 0.2 MPa. A ratio of MHD pressure drop to that of non-magnetic field increases with magnetic flux density and a mass flow rate ratio of lithium to helium in low helium velocity region. However, as increasing the helium velocity, the increment of MHD pressure drop with the magnetic flux density is much reduced and then becomes almost zero. At this condition, the MHD pressure drop of the annular-mist flow becomes much smaller than that of lithium single phase flow with the same lithium mass flow at the high magnetic flux density. Heat transfer coefficient ratio of the helium-lithium annular-mist flow to helium single phase in the non-magnetic field is well correlated by a ratio of the mass flow rate of lithium to helium. The heat transfer coefficient in the magnetic field increases with the magnetic flux density and then terminates at a certain value depending on the mass flow rate ratio and the helium velocity. These characteristics of the MHD pressure drop and the heat transfer in the magnetic field suggest that the helium-lithium annular-mist flow is effectively applicable to cooling of the high heat flux wall in a strong magnetic field like a first wall of a magnetic confinement fusion reactors. (author)

  17. The effect of magnetic field on instabilities of heat transfer from an obstacle in a channel

    International Nuclear Information System (INIS)

    Rashidi, S.; Esfahani, J.A.

    2015-01-01

    This paper presents forced convective heat transfer in a channel with a built-in square obstacle. The governing equations with the boundary conditions are solved using a finite volume method. The computations were done for a fixed blockage ratio (S=1/8) at Pr=0.71, and Reynolds (Re) and Stuart (N) numbers ranging from 1 to 250 and 0 to 10, respectively. The results are presented to show the effect of the channel walls and streamwise magnetic field at different Reynolds numbers on forced convection heat transfer from a square cylinder. A correlation is obtained for Nusselt number, in which the effect of a magnetic field is taken into account. The obtained results revealed that the existence of channel walls decreases the effects of magnetic field on Nusselt number. It also showed that by increasing Stuart number the thickness of thermal boundary layer increases and the convective heat transfer decreases. - Highlights: • The magnetic field is used to control the instabilities of heat transfer. • The thickness of thermal boundary layer increases by increasing Stuart number. • Unsteadiness in temperature field increases with increase in Reynolds number. • Time-averaged Nusselt number decreases with increase in Stuart number. • The Lorentz forces are much denser near the surface of the obstacle

  18. Testing of Prototype Magnetic Suspension Cryogenic Transfer Line

    Science.gov (United States)

    Fesmire, J. E.; Augustynowicz, S. D.; Nagy, Z. F.; Sojourner, S. J.; Shu, Q. S.; Cheng, G.; Susta, J. T.

    2006-04-01

    A 6-meter prototype cryogenic transfer line with magnetic suspension was tested for its mechanical and thermal performance at the Cryogenics Test Laboratory of NASA Kennedy Space Center (KSC). A test facility with two cryogenic end-boxes was designed and commissioned for the testing. Suspension mechanisms were verified through a series of tests with liquid nitrogen. The thermal performance of the prototype was determined using the new test apparatus. The tested prototype has incorporated temperature and vacuum pressure data acquisition ports, customized interfaces to cryogenic end-boxes, and instrumentation. All tests were conducted under simulated onsite transfer line working conditions. A static (boiloff rate measurement) testing method was employed to demonstrate the gross heat leak in the tested article. The real-time temperature distribution, vacuum level, levitation distance, and mass flow rate were measured. The main purpose of this paper is to summarize the testing facility design and preparation, test procedure, and primary test results. Special arrangements (such as turning on/off mechanical support units, observing levitation gap, and setting up the flowmeter) in testing of such a magnetically levitated transfer line are also discussed. Preliminary results show that the heat leak reduction of approximately one-third to one-half is achievable through such transfer lines with a magnetic suspension system.

  19. Magnetization transfer imaging of normal and abnormal testis: preliminary results

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Ntorkou, Alexandra; Maliakas, Vasilios; Argyropoulou, Maria I.; Baltogiannis, Dimitrios; Sylakos, Anastasios; Sofikitis, Nikolaos; Stavrou, Sotirios; Astrakas, Loukas G.

    2016-01-01

    The aim was to determine the magnetization transfer ratio (MTR) of normal testes, possible variations with age and to assess the feasibility of MTR in characterizing various testicular lesions. Eighty-six men were included. A three-dimensional gradient-echo MT sequence was performed, with/without an on-resonance binomial prepulse. MTR was calculated as: (SIo-SIm)/(SIo) x 100 %, where SIm and SIo refers to signal intensities with and without the saturation pulse, respectively. Subjects were classified as: group 1, 20-39 years; group 2, 40-65 years; and group 3, older than 65 years of age. Analysis of variance (ANOVA) followed by the least significant difference test was used to assess variations of MTR with age. Comparison between the MTR of normal testis, malignant and benign testicular lesions was performed using independent-samples t testing. ANOVA revealed differences of MTR between age groups (F = 7.51, P = 0.001). Significant differences between groups 1, 2 (P = 0.011) and 1, 3 (P < 0.001) were found, but not between 2, 3 (P = 0.082). The MTR (in percent) of testicular carcinomas was 55.0 ± 3.2, significantly higher than that of benign lesions (50.3 ± 4.0, P = 0.02) and of normal testes (47.4 ± 2.2, P < 0.001). MTR of normal testes decreases with age. MTR might be helpful in the diagnostic work-up of testicular lesions. (orig.)

  20. Assisted Writing in Spin Transfer Torque Magnetic Tunnel Junctions

    Science.gov (United States)

    Ganguly, Samiran; Ahmed, Zeeshan; Datta, Supriyo; Marinero, Ernesto E.

    2015-03-01

    Spin transfer torque driven MRAM devices are now in an advanced state of development, and the importance of reducing the current requirement for writing information is well recognized. Different approaches to assist the writing process have been proposed such as spin orbit torque, spin Hall effect, voltage controlled magnetic anisotropy and thermal excitation. In this work,we report on our comparative study using the Spin-Circuit Approach regarding the total energy, the switching speed and energy-delay products for different assisted writing approaches in STT-MTJ devices using PMA magnets.

  1. Magnetic error analysis of recycler pbar injection transfer line

    Energy Technology Data Exchange (ETDEWEB)

    Yang, M.J.; /Fermilab

    2007-06-01

    Detailed study of Fermilab Recycler Ring anti-proton injection line became feasible with its BPM system upgrade, though the beamline has been in existence and operational since year 2000. Previous attempts were not fruitful due to limitations in the BPM system. Among the objectives are the assessment of beamline optics and the presence of error fields. In particular the field region of the permanent Lambertson magnets at both ends of R22 transfer line will be scrutinized.

  2. The influence of streamwise vortices on turbulent heat transfer in rectangular ducts with various aspect ratios

    International Nuclear Information System (INIS)

    Choi, Hang Seok; Park, Tae Seon

    2013-01-01

    Highlights: ► With changing aspect ratio, the effect of secondary flows on the turbulent heat transfer is scrutinized by a LES. ► The conditional sampling technique of instantaneous near-wall streamwise vortices is developed. ► Clockwise and counter-clockwise rotating streamwise vortices are sampled and discussed with the wall heat transfer. ► The hot-sweep motions of CW and CCW vortices clearly appear with increasing aspect ratio. -- Abstract: The effect of aspect ratio of rectangular duct on the turbulent flow and heat transfer is very important for its engineering applications. But the turbulent thermal fields have not been fundamentally scrutinized in spite of its engineering significance especially for cooling device. Hence, in the present study, large eddy simulation is applied to the turbulent flow and heat transfer in rectangular ducts with varying aspect ratio. The turbulent statistics of the flow and thermal quantities are calculated and the characteristics of wall Nusselt number are investigated for each rectangular duct. Especially, to scrutinize near-wall streamwise vortices, a conditional sampling technique is developed and adopted. Clockwise and counter-clockwise rotating streamwise vortices are sampled and the probability density function of the vortex circulation Reynolds number and wall Nusselt number are calculated. From the results, the time-averaged secondary flow caused by instantaneous vortical motions has a great effect on the heat and momentum transport of the flow in the rectangular ducts. Hence, the wall Nusselt number is enhanced near the downwash flow region of the secondary flow. However, with increasing the aspect ratio, the effects of the hot-sweep flow of the clockwise and counter-clockwise rotating vortices become equally dominant near the wall normal bisector of the ducts. During time averaging process, these two counter-rotating vortices are canceled out each other diminishing a secondary flow but they still enhance the

  3. New magnet transport system for the LHC beam transfer lines

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system (pictured here in one of the tunnels) is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The lead vehicle is powered by an electric rail set into the roof of the tunnel. The system is backed up by electrical batteries that enable it to operate in the absence of an outside power source or in the event of power failure. Last but not least, for the long-distance transport of magnets, it can be optically guided by a line traced on the tunnel floor. The convoy moves through the particularly narr...

  4. Magnetic metamaterial superlens for increased range wireless power transfer.

    Science.gov (United States)

    Lipworth, Guy; Ensworth, Joshua; Seetharam, Kushal; Huang, Da; Lee, Jae Seung; Schmalenberg, Paul; Nomura, Tsuyoshi; Reynolds, Matthew S; Smith, David R; Urzhumov, Yaroslav

    2014-01-10

    The ability to wirelessly power electrical devices is becoming of greater urgency as a component of energy conservation and sustainability efforts. Due to health and safety concerns, most wireless power transfer (WPT) schemes utilize very low frequency, quasi-static, magnetic fields; power transfer occurs via magneto-inductive (MI) coupling between conducting loops serving as transmitter and receiver. At the "long range" regime - referring to distances larger than the diameter of the largest loop - WPT efficiency in free space falls off as (1/d)(6); power loss quickly approaches 100% and limits practical implementations of WPT to relatively tight distances between power source and device. A "superlens", however, can concentrate the magnetic near fields of a source. Here, we demonstrate the impact of a magnetic metamaterial (MM) superlens on long-range near-field WPT, quantitatively confirming in simulation and measurement at 13-16 MHz the conditions under which the superlens can enhance power transfer efficiency compared to the lens-less free-space system.

  5. Graphene-ferromagnet interfaces: hybridization, magnetization and charge transfer.

    Science.gov (United States)

    Abtew, Tesfaye; Shih, Bi-Ching; Banerjee, Sarbajit; Zhang, Peihong

    2013-03-07

    Electronic and magnetic properties of graphene-ferromagnet interfaces are investigated using first-principles electronic structure methods in which a single layer graphene is adsorbed on Ni(111) and Co(111) surfaces. Due to the symmetry matching and orbital overlap, the hybridization between graphene pπ and Ni (or Co) d(z(2)) states is very strong. This pd hybridization, which is both spin and k dependent, greatly affects the electronic and magnetic properties of the interface, resulting in a significantly reduced (by about 20% for Ni and 10% for Co) local magnetic moment of the top ferromagnetic layer at the interface and an induced spin polarization on the graphene layer. The calculated induced magnetic moment on the graphene layer agrees well with a recent experiment. In addition, a substantial charge transfer across the graphene-ferromagnet interfaces is observed. We also investigate the effects of thickness of the ferromagnet slab on the calculated electronic and magnetic properties of the interface. The strength of the pd hybridization and the thickness-dependent interfacial properties may be exploited to design structures with desirable magnetic and transport properties for spintronic applications.

  6. The Rejuvenating Effect in Hot Asphalt Recycling by Mortar Transfer Ratio and Image Analysis.

    Science.gov (United States)

    Wang, Fusong; Wang, Zipeng; Li, Chao; Xiao, Yue; Wu, Shaopeng; Pan, Pan

    2017-05-24

    Using a rejuvenator to improve the performance of asphalt pavement is an effective and economic way of hot asphalt recycling. This research analyzes the rejuvenating effect on aged asphalt by means of a Mortar Transfer Ratio (MTR) test, which concerns the ratio of asphalt mortar that moves from recycled aggregates (RAP aggregates) to fresh added aggregates when aged asphalt is treated with a regenerating agent and comes into contact with fresh aggregates. The proposed MTR test analyzes the regeneration in terms of the softening degree on aged asphalt when the rejuvenator is applied. The covered area ratio is studied with an image analyzing tool to understand the possibility of mortar transferring from RAP aggregates to fresh aggregates. Additionally, a micro-crack closure test is conducted and observed through a microscope. The repairing ability and diffusion characteristics of micro-cracks can therefore be analyzed. The test results demonstrate that the proposed mortar transfer ratio is a feasible way to evaluate rejuvenator diffusion during hot recycling. The mortar transfer ratio and uncovered area ratio on fresh aggregates are compatible, and can be used to quantify the contribution of the rejuvenator. Within a certain temperature range, the diffusing effect of the rejuvenator is better when the diffusing temperature is higher. The diffusion time of the rejuvenator is optimum when diffusion occurs for 4-8 h. When the rejuvenator is properly applied, the rough and cracking surface can be repaired, resulting in better covered aggregates. The micro-closure analysis visually indicates that rejuvenators can be used to repair the RAP aggregates during hot recycling.

  7. Recoil curve properties and coercive force decrease ratio in NdFeB sintered magnets

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yutaka, E-mail: Yutaka_Matsuura@hitachi-metals.co.jp; Kitai, Nobuyuki; Ishii, Rintaro; Natsumeda, Toshimitsu; Hoshijima, Jun

    2013-11-15

    It is examined that whether a reverse domain and magnetic domain wall exist in a lower demagnetization area than the coercive force and whether the observed demagnetization ratio curve can be explained using the alignment distribution function or not. From measurements of the recoil curve in the low demagnetization field, it was confirmed that minor demagnetization occurred in every demagnetization field and magnets of every grade of coercive force. The alignment distribution of Nd{sub 2}Fe{sub 14}B grains was also measured by electron back-scattering diffraction (EBSD). The alignments and the coercive force decrease ratios were calculated using these alignment distributions. These data were compared against the results obtained from magnetization measurements. From EBSD data, it was found that the alignment distributions of magnets used in this experiment were close to a Gaussian distribution. It was also found that there was no difference in the alignment distribution between magnets with Dy and without Dy, even though the coercive force decrease ratios were Dy dependent. The calculated alignments using the alignment distribution functions were close to the values of magnetization measurements. However, it was found that the calculated coercive force decrease ratios were different from the results obtained from magnetization measurement. - Highlights: • Reverse magnetic domains already exist lower magnetic field than coercive force. • Demagnetization happens not only from surface but also from inside of magnets. • Calculated alignment agrees well with that of the magnetic properties measurement. • Coercive force decrease ratio could not explain from alignment distribution. • We could not find any difference with and without Dy magnets in alignment distribution.

  8. Magnetic resonance findings in amyotrophic lateral sclerosis using a spin echo magnetization transfer sequence: preliminary report

    Directory of Open Access Journals (Sweden)

    ROCHA ANTÔNIO JOSÉ DA

    1999-01-01

    Full Text Available We present the magnetic resonance (MR findings of five patients with amyotrophic lateral sclerosis (ALS using a spin-echo sequence with an additional magnetization transfer (MT pulse on T1-weighted images (T1 SE/MT. These findings were absent in the control group and consisted of hyperintensity of the corticospinal tract. Moreover we discuss the principles and the use of this fast but simple MR technique in the diagnosis of ALS

  9. Magnetization reversal in textured Fe nanoparticles having different aspect ratios

    International Nuclear Information System (INIS)

    Garcia Sanchez, F.; Chubykalo-Fesenko, O.; Crespo, P.; Hernando, A.; Gonzalez, J.M.

    2005-01-01

    The use of micromagnetic models on the simulation of the magnetization reversal allows approaching the 'ad hoc' design of materials for particular applications. As an example of this and trying to identify a particulate system with reduced interparticle dipolar interactions, we report on the results of a study of the hysteretic properties of textured Fe particles having thicknesses of the order of the units of nanometre and in-plane dimensions from 400x30 to 400x250 nm. Our results show that for sufficiently wide particles the moment configurations at the remanence correspond to an outer shell where the moments are essentially oriented along the direction parallel to the particle surface (therefore minimizing the surface poles) and an inner core (having larger volume than the shell) in which the moments point along one of the two easiest crystallographic directions. The reversal field of the outer shell is larger than that of the core and consequently the latter coincides with the global particle coercivity

  10. A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

    Science.gov (United States)

    Goodrich, K C; Blatter, D D; Parker, D L; Du, Y P; Meyer, K J; Bernstein, M A

    1996-06-01

    The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

  11. Destruction of magnetic surfaces in the edge of a large aspect ratio Tokamak with ergodic limiter

    International Nuclear Information System (INIS)

    Viana, R.L.; Caldas, I.L.

    1990-01-01

    The model of Martin and Taylor for a large aspect-ratio Tokamak with an ergodic limiter is considered. In order to study the onset of chaotic behaviour for the magnetic field lines in the edge of the vessel, a Hamiltonian formulation is constructed for the system and the overlap of two peripheral magnetic islands is considered. So, it is possible to determine a threshold for the ergodic limiter current to cause destruction of rational magnetic surfaces in this region. (Author)

  12. Leptothrix sp sheaths modified with iron oxide particles: Magnetically responsive, high aspect ratio functional material

    Czech Academy of Sciences Publication Activity Database

    Šafařík, Ivo; Angelova, R.; Baldíková, E.; Pospíšková, K.; Šafaříková, Miroslava

    2017-01-01

    Roč. 71, February (2017), s. 1342-1346 ISSN 0928-4931 Institutional support: RVO:60077344 Keywords : Leptothrix * magnetic modification * iron oxide * high aspect ratio material Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Materials engineering Impact factor: 4.164, year: 2016

  13. Spin transfer torque generated magnetic droplet solitons (invited)

    International Nuclear Information System (INIS)

    Chung, S.; Mohseni, S. M.; Sani, S. R.; Iacocca, E.; Dumas, R. K.; Pogoryelov, Ye.; Anh Nguyen, T. N.; Muduli, P. K.; Eklund, A.; Hoefer, M.; Åkerman, J.

    2014-01-01

    We present recent experimental and numerical advancements in the understanding of spin transfer torque generated magnetic droplet solitons. The experimental work focuses on nano-contact spin torque oscillators (NC-STOs) based on orthogonal (pseudo) spin valves where the Co fixed layer has an easy-plane anisotropy, and the [Co/Ni] free layer has a strong perpendicular magnetic anisotropy. The NC-STO resistance and microwave signal generation are measured simultaneously as a function of drive current and applied perpendicular magnetic field. Both exhibit dramatic transitions at a certain current dependent critical field value, where the microwave frequency drops 10 GHz, modulation sidebands appear, and the resistance exhibits a jump, while the magnetoresistance changes sign. We interpret these observations as the nucleation of a magnetic droplet soliton with a large fraction of its magnetization processing with an angle greater than 90°, i.e., around a direction opposite that of the applied field. This interpretation is corroborated by numerical simulations. When the field is further increased, we find that the droplet eventually collapses under the pressure from the Zeeman energy

  14. Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

    Science.gov (United States)

    Moriyama, Shin-Ichi; Hiraki, Naoji; Watanabe, Katsuhide; Kanemitsu, Yoichi

    1996-01-01

    This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

  15. Transfer Effect Ratio of Loosely Coupled Coils for Wireless Power through CB Wall under Station Blackout(SBO)

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kil Mo; Hong, Seong Wan; Song, Jin Ho; Baek, Won Pil [KAERI, Daejeon (Korea, Republic of); Cheon, Sang Hoon [ETRI, Daejeon (Korea, Republic of)

    2016-05-15

    Instrumentations have had the bad situation like a station blackout(SBO) as the severe accident in nuclear power plants. In recent years, there has been an increasing interest in wireless power transfer technology, In particular, significant processing has been charted for inductively coupled systems. In this paper, we introduce some new method as transfer effect ratio of loosely coupled coils for wireless power through the CB(Container Building) wall as an alternative method under a station blackout of severe accident conditions in nuclear power plants. As an equivalent circuit model that can describe wireless energy transfer systems via coupled magnetic resonances for the CB thickness wall. The solution shows that the transmission efficiency can be decreased simply by adjusting the spacing between the power and the sending coils or between the receiving and the load coils. The system design can be calculated the frequency characteristics, and then an equivalent circuit model was developed from the node equation and established in an electric design automation tool.

  16. Transfer Effect Ratio of Loosely Coupled Coils for Wireless Power through CB Wall under Station Blackout(SBO)

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Hong, Seong Wan; Song, Jin Ho; Baek, Won Pil; Cheon, Sang Hoon

    2016-01-01

    Instrumentations have had the bad situation like a station blackout(SBO) as the severe accident in nuclear power plants. In recent years, there has been an increasing interest in wireless power transfer technology, In particular, significant processing has been charted for inductively coupled systems. In this paper, we introduce some new method as transfer effect ratio of loosely coupled coils for wireless power through the CB(Container Building) wall as an alternative method under a station blackout of severe accident conditions in nuclear power plants. As an equivalent circuit model that can describe wireless energy transfer systems via coupled magnetic resonances for the CB thickness wall. The solution shows that the transmission efficiency can be decreased simply by adjusting the spacing between the power and the sending coils or between the receiving and the load coils. The system design can be calculated the frequency characteristics, and then an equivalent circuit model was developed from the node equation and established in an electric design automation tool

  17. The Quadrupole Magnets for the LHC Injection Transfer Lines

    CERN Document Server

    Chertok, I; Churkin, I N; Giesch, Manfred; Golubenko, O B; Kalbreier, Willi; Kouba, G; Mejidzade, V; Mikhailov, S; Steshov, A; Sukhanov, A; Sukhina, B; Schirm, K M; Weisse, E

    2000-01-01

    Two injection transfer lines, each about 2.8 km long, are being built to transfer protons at 450 GeV from the Super Proton Synchrotron (SPS) to the Large Hadron Collider (LHC). A total of 180 quadrupole magnets are required; they are produced in the framework of the contribution of the Russian Federation to the construction of the LHC. The classical quadrupoles, built from laminated steel cores and copper coils, have a core length of 1.4 m, an inscribed diameter of 32 mm and a strength of 53.5 T/m at a current of 530 A. The total weight of one magnet is 1.1 ton. For obtaining the required field quality at the small inscribed diameter, great care in the stamping of the laminations and the assembly of quadrants is necessary. Special instruments have been developed to measure, with a precision of some mm, the variations of the pole gaps over the full length of the magnet and correlate them to the obtained field distribution. The design has been developed in a collaboration between BINP and CERN. Fabrication and ...

  18. Cellular transfer of magnetic nanoparticles via cell microvesicles: impact on cell tracking by magnetic resonance imaging.

    Science.gov (United States)

    Silva, Amanda K Andriola; Wilhelm, Claire; Kolosnjaj-Tabi, Jelena; Luciani, Nathalie; Gazeau, Florence

    2012-05-01

    Cell labeling with magnetic nanoparticles can be used to monitor the fate of transplanted cells in vivo by magnetic resonance imaging. However, nanoparticles initially internalized in administered cells might end up in other cells of the host organism. We investigated a mechanism of intercellular cross-transfer of magnetic nanoparticles to different types of recipient cells via cell microvesicles released under cellular stress. Three cell types (mesenchymal stem cells, endothelial cells and macrophages) were labeled with 8-nm iron oxide nanoparticles. Then cells underwent starvation stress, during which they produced microvesicles that were subsequently transferred to unlabeled recipient cells. The analysis of the magnetophoretic mobility of donor cells indicated that magnetic load was partially lost under cell stress. Microvesicles shed by stressed cells participated in the release of magnetic label. Moreover, such microvesicles were uptaken by naïve cells, resulting in cellular redistribution of nanoparticles. Iron load of recipient cells allowed their detection by MRI. Cell microvesicles released under stress may be disseminated throughout the organism, where they can be uptaken by host cells. The transferred cargo may be sufficient to allow MRI detection of these secondarily labeled cells, leading to misinterpretations of the effectiveness of transplanted cells.

  19. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Rovira, A.; Alonso, J.; Cucurella, G.; Nos, C.; Tintore, M.; Pedraza, S.; Rio, J.; Montalban, X.

    1997-01-01

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs

  20. Hyperthermia in low aspect-ratio magnetic nanotubes for biomedical applications

    Science.gov (United States)

    Gutierrez-Guzman, D. F.; Lizardi, L. I.; Otálora, J. A.; Landeros, P.

    2017-03-01

    A simple model for the magnetization reversal process of low aspect-ratio ferromagnetic nanotubes (MNTs) is presented. Because of advantages over other geometries, these structures are interesting for biomedical applications, such as magnetic hyperthermia cancer therapy, where the heat released during magnetic reversal is used to destroy tumors. For example, the tubular geometry provides two independent functional surfaces that may be selectively manipulated and also gives a storage cavity. Owing to their large surface to weight ratio and low mass density, MNTs are not decanted by gravity. We calculated magnetic phase diagrams, energy barriers, nucleation fields, and the amount of dissipated heat and specific absorption rate for magnetite nanotubes. The geometrical parameters were varied, and simple formulae were used to optimize the tube response under alternating excitation, as required for magnetic hyperthermia applications.

  1. Energy Transfer and Dual Cascade in Kinetic Magnetized Plasma Turbulence

    International Nuclear Information System (INIS)

    Plunk, G. G.; Tatsuno, T.

    2011-01-01

    The question of how nonlinear interactions redistribute the energy of fluctuations across available degrees of freedom is of fundamental importance in the study of turbulence and transport in magnetized weakly collisional plasmas, ranging from space settings to fusion devices. In this Letter, we present a theory for the dual cascade found in such plasmas, which predicts a range of new behavior that distinguishes this cascade from that of neutral fluid turbulence. These phenomena are explained in terms of the constrained nature of spectral transfer in nonlinear gyrokinetics. Accompanying this theory are the first observations of these phenomena, obtained via direct numerical simulations using the gyrokinetic code AstroGK. The basic mechanisms that are found provide a framework for understanding the turbulent energy transfer that couples scales both locally and nonlocally.

  2. Energy Transfer and Dual Cascade in Kinetic Magnetized Plasma Turbulence

    Science.gov (United States)

    Plunk, G. G.; Tatsuno, T.

    2011-04-01

    The question of how nonlinear interactions redistribute the energy of fluctuations across available degrees of freedom is of fundamental importance in the study of turbulence and transport in magnetized weakly collisional plasmas, ranging from space settings to fusion devices. In this Letter, we present a theory for the dual cascade found in such plasmas, which predicts a range of new behavior that distinguishes this cascade from that of neutral fluid turbulence. These phenomena are explained in terms of the constrained nature of spectral transfer in nonlinear gyrokinetics. Accompanying this theory are the first observations of these phenomena, obtained via direct numerical simulations using the gyrokinetic code AstroGK. The basic mechanisms that are found provide a framework for understanding the turbulent energy transfer that couples scales both locally and nonlocally.

  3. Spin transfer torque with spin diffusion in magnetic tunnel junctions

    KAUST Repository

    Manchon, Aurelien

    2012-08-09

    Spin transport in magnetic tunnel junctions in the presence of spin diffusion is considered theoretically. Combining ballistic tunneling across the barrier and diffusive transport in the electrodes, we solve the spin dynamics equation in the metallic layers. We show that spin diffusion mixes the transverse spin current components and dramatically modifies the bias dependence of the effective spin transfer torque. This leads to a significant linear bias dependence of the out-of-plane torque, as well as a nonconventional thickness dependence of both spin torque components.

  4. Lift to Drag Ratio Analysis in Magnetic Levitation with an Electrodynamic Wheel

    Science.gov (United States)

    Gutarra-Leon, Angel; Cordrey, Vincent; Majewski, Walerian

    Our experiments explored inductive magnetic levitation (MagLev) using simple permanent magnets and conductive tracks. Our investigations used a circular Halbach array with a 1 Tesla variable magnetic field on the outer rim of the ring. Such a system is usually called an Electrodynamic Wheel (EDW). Rotating this wheel around a horizontal axis above or below a flat conducting surface should induce eddy currents in said surface through the variable magnetic flux. The eddy currents produce, in turn, their own magnetic fields, which interact with the magnets of the EDW. We constructed a four-inch diameter Electrodynamic Wheel using twelve Neodymium permanent magnets and demonstrated that the magnetic interactions produce both lift and drag forces on the EDW. These forces can be used for levitation and propulsion of the EDW to produce magnetic levitation without coils and complex control circuitry. We achieved full levitation of the non-magnetic aluminum and copper plates. Our results confirm the expected behavior of lift to drag ratio as proportional to (L/R) ω, with L and R being the inductance and resistance of the track plate, and ω being the angular velocity of the magnetic flux. Supported by grants from the Virginia Academy of Science, Society of Physics Students, Virginia Community College System, and the NVCC Educational Foundation.

  5. Molecular, dynamic, and structural origin of inhomogeneous magnetization transfer in lipid membranes.

    Science.gov (United States)

    Swanson, Scott D; Malyarenko, Dariya I; Fabiilli, Mario L; Welsh, Robert C; Nielsen, Jon-Fredrik; Srinivasan, Ashok

    2017-03-01

    To elucidate the dynamic, structural, and molecular properties that create inhomogeneous magnetization transfer (ihMT) contrast. Amphiphilic lipids, lamellar phospholipids with cholesterol, and bovine spinal cord (BSC) specimens were examined along with nonlipid systems. Magnetization transfer (MT), enhanced MT (eMT, obtained with double-sided radiofrequency saturation), ihMT (MT - eMT), and dipolar relaxation, T 1D , were measured at 2.0 and 11.7 T. The amplitude of ihMT ratio (ihMTR) is positively correlated with T 1D values. Both ihMTR and T 1D increase with increasing temperature in BSC white matter and in phospholipids and decrease with temperature in other lipids. Changes in ihMTR with temperature arise primarily from alterations in MT rather than eMT. Spectral width of MT, eMT, and ihMT increases with increasing carbon chain length. Concerted motions of phospholipids in white matter decrease proton spin diffusion leading to increased proton T 1D times and increased ihMT amplitudes, consistent with decoupling of Zeeman and dipolar spin reservoirs. Molecular specificity and dynamic sensitivity of ihMT contrast make it a suitable candidate for probing myelin membrane disorders. Magn Reson Med 77:1318-1328, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Quantitative Magnetization Transfer in Monitoring Glioblastoma (GBM) Response to Therapy.

    Science.gov (United States)

    Mehrabian, Hatef; Myrehaug, Sten; Soliman, Hany; Sahgal, Arjun; Stanisz, Greg J

    2018-02-06

    Quantitative magnetization transfer (qMT) was used as a biomarker to monitor glioblastoma (GBM) response to chemo-radiation and identify the earliest time-point qMT could differentiate progressors from non-progressors. Nineteen GBM patients were recruited and MRI-scanned before (Day 0 ), two weeks (Day 14 ), and four weeks (Day 28 ) into the treatment, and one month after the end of the treatment (Day 70 ). Comprehensive qMT data was acquired, and a two-pool MT model was fit to the data. Response was determined at 3-8 months following the end of chemo-radiation. The amount of magnetization transfer ([Formula: see text]) was significantly lower in GBM compared to normal appearing white matter (p GBM are more sensitive to treatment effects compared to clinically used metrics. qMT could assess tumor aggressiveness and identify early progressors even before the treatment. Changes in qMT parameters within the first 14 days of the treatment were capable of separating early progressors from non-progressors, making qMT a promising biomarker to guide adaptive radiotherapy for GBM.

  7. Magnetic torque transferring study for bulk High-Tc superconductors and permanent magnets

    International Nuclear Information System (INIS)

    Wongsatanawarid, A; Suzuki, A; Seki, H; Murakami, M

    2009-01-01

    The torque transferring mechanism taking place in a superconducting mixer design has been studied. Several coupling magnetic arrangements were investigated for more details in the engineering design. A bulk superconductor sample was used to study the torque forces for various cooling gaps, and the twist angle dependence was also monitored for the rotational stiffness in stability. The experimental data with four permanent magnet configurations have been studied in the present work. The maximum torque forces are summarized for usage of engineering design with various gaps. The torque/gap characteristics for four configurations were also measured for the optimisation of the torque at a designed operating gap.

  8. Direct characterization of spin-transfer switching of nano-scale magnetic tunnel junctions using a conductive atomic force microscope

    International Nuclear Information System (INIS)

    Lee, Jia-Mou; Yang, Dong-Chin; Lee, Ching-Ming; Ye, Lin-Xiu; Chang, Yao-Jen; Wu, Te-ho; Lee, Yen-Chi; Wu, Jong-Ching

    2013-01-01

    We present an alternative method of spin-transfer-induced magnetization switching for magnetic tunnel junctions (MTJs) using a conductive atomic force microscope (CAFM) with pulsed current. The nominal MTJ cells' dimensions were 200 × 400 nm 2 . The AFM probes were coated with a Pt layer via sputtering to withstand up to several milliamperes. The pulsed current measurements, with pulse duration varying from 5 to 300 ms, revealed a magnetoresistance ratio of up to 120%, and an estimated intrinsic switching current density, based on the thermal activation model, of 3.94 MA cm −2 . This method demonstrates the potential skill to characterize nanometre-scale magnetic devices. (paper)

  9. The effect of ratio and interval training on Pavlovian-instrumental transfer in mice.

    Directory of Open Access Journals (Sweden)

    Brian J Wiltgen

    Full Text Available Conditional stimuli (CS that are paired with reward can be used to motivate instrumental responses. This process is called Pavlovian-instrumental transfer (PIT. A recent study in rats suggested that habitual responses are particularly sensitive to the motivational effects of reward cues. The current experiments examined this idea using ratio and interval training in mice. Two groups of animals were trained to lever press for food pellets that were delivered on random ratio or random interval schedules. Devaluation tests revealed that interval training led to habitual responding while ratio training produced goal-directed actions. The presentation of CSs paired with reward led to positive transfer in both groups, however, the size of this effect was much larger in mice that were trained on interval schedules. This result suggests that habitual responses are more sensitive to the motivational influence of reward cues than goal-directed actions. The implications for neurobiological models of motivation and drug seeking behaviors are discussed.

  10. Improved power transfer to wearable systems through stretchable magnetic composites

    Science.gov (United States)

    Lazarus, N.; Bedair, S. S.

    2016-05-01

    The use of wireless power transfer is common in stretchable electronics since physical wiring can be easily destroyed as the system is stretched. This work presents the first demonstration of improved inductive power coupling to a stretchable system through the addition of a thin layer of ferroelastomeric material. A ferroelastomer, an elastomeric polymer loaded with magnetic particulates, has a permeability greater than one while retaining the ability to survive significant mechanical strains. A recently developed ferroelastomer composite based on sendust platelets within a soft silicone elastomer was incorporated into liquid metal stretchable inductors based on the liquid metal galinstan in fluidic channels. For a single-turn inductor, the maximum power transfer efficiency rises from 71 % with no backplane, to 81 % for a rigid ferrite backplane on the transmitter side alone, to 86 % with a ferroelastomer backplane on the receiver side as well. The coupling between a commercial wireless power transmitter coil with ferrite backplane to a five-turn liquid metal inductor was also investigated, finding an improvement in power transfer efficiency from 81 % with only a rigid backplane to 90 % with the addition of the ferroelastomer backplane. Both the single and multi-turn inductors were demonstrated surviving up to 50 % uniaxial applied strain.

  11. Energy transfers and magnetic energy growth in small-scale dynamo

    KAUST Repository

    Kumar, Rohit Raj

    2013-12-01

    In this letter we investigate the dynamics of magnetic energy growth in small-scale dynamo by studying energy transfers, mainly energy fluxes and shell-to-shell energy transfers. We perform dynamo simulations for the magnetic Prandtl number Pm = 20 on 10243 grid using the pseudospectral method. We demonstrate that the magnetic energy growth is caused by nonlocal energy transfers from the large-scale or forcing-scale velocity field to small-scale magnetic field. The peak of these energy transfers moves towards lower wave numbers as dynamo evolves, which is the reason why the integral scale of the magnetic field increases with time. The energy transfers U2U (velocity to velocity) and B2B (magnetic to magnetic) are forward and local. Copyright © EPLA, 2013.

  12. ORBITAL AND MASS RATIO EVOLUTION OF PROTOBINARIES DRIVEN BY MAGNETIC BRAKING

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Bo; Li, Zhi-Yun [Astronomy Department, University of Virginia, Charlottesville, VA 22904 (United States)

    2013-01-20

    The majority of stars reside in multiple systems, especially binaries. The formation and early evolution of binaries is a longstanding problem in star formation that is not yet fully understood. In particular, how the magnetic field observed in star-forming cores shapes the binary characteristics remains relatively unexplored. We demonstrate numerically, using an MHD version of the ENZO AMR hydro code, that a magnetic field of the observed strength can drastically change two of the basic quantities that characterize a binary system: the orbital separation and mass ratio of the two components. Our calculations focus on the protostellar mass accretion phase, after a pair of stellar 'seeds' have already formed. We find that in dense cores magnetized to a realistic level, the angular momentum of the material accreted by the protobinary is greatly reduced by magnetic braking. Accretion of strongly braked material shrinks the protobinary separation by a large factor compared to the non-magnetic case. The magnetic braking also changes the evolution of the mass ratio of unequal-mass protobinaries by producing material of low specific angular momentum that accretes preferentially onto the more massive primary star rather than the secondary. This is in contrast with the preferential mass accretion onto the secondary previously found numerically for protobinaries accreting from an unmagnetized envelope, which tends to drive the mass ratio toward unity. In addition, the magnetic field greatly modifies the morphology and dynamics of the protobinary accretion flow. It suppresses the traditional circumstellar and circumbinary disks that feed the protobinary in the non-magnetic case; the binary is fed instead by a fast collapsing pseudodisk whose rotation is strongly braked. The magnetic braking-driven inward migration of binaries from their birth locations may be constrained by high-resolution observations of the orbital distribution of deeply embedded protobinaries

  13. Spin and energy transfer between magnetic ions and free carriers in diluted-magnetic semiconductor heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Yakovlev, D.R. [Experimental Physics 2, University of Dortmund, 44227 Dortmund (Germany); Ioffe Physico-Technical Institute, Russian Academy of Sciences, 194021 St. Petersburg (Russian Federation); Kneip, M.; Bayer, M. [Experimental Physics 2, University of Dortmund, 44227 Dortmund (Germany); Maksimov, A.A.; Tartakovskii, I.I. [Institute of Solid State Physics, Russian Academy of Sciences, 142432 Chernogolovka (Russian Federation); Keller, D.; Ossau, W.; Molenkamp, L.W. [Physikalisches Institut der Universitaet Wuerzburg, 97074 Wuerzburg (Germany); Scherbakov, A.V.; Akimov, A.V. [Ioffe Physico-Technical Institute, Russian Academy of Sciences, 194021 St. Petersburg (Russian Federation); Waag, A. [Abteilung Halbleiterphysik, Universitaet Ulm, 89081 Ulm (Germany)

    2004-03-01

    In this paper we give a brief overview of our studies on dynamical processes in diluted-magnetic-semiconductor heterostructures based on (Zn,Mn)Se and (Cd,Mn)Te. Presence of free carriers is an important factor which determines the energy- and spin transfer in a coupled systems of magnetic ions, lattice (the phonon system) and carriers. We report also new data on dynamical response of magnetic ions interacting with photogenerated electron-hole plasma. (Zn,Mn)Se/(Zn,Be)Se structures with relatively high Mn content of 11% provide spin-lattice relaxation time of about 20 ns, which is considerably shorter then the characteristic times of nonequilibrium phonons ranging to 1 {mu}s. (copyright 2004 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  14. Momentum transfer theory of non-conservative charged particle transport in crossed electric and magnetic fields

    International Nuclear Information System (INIS)

    Vrhovac, S.B.; Petrovic, Z.Lj.

    1995-01-01

    Momentum - transfer approximation is applied to momentum and energy balance equations describing reacting particle swarms in gases in crossed electric and magnetic fields. Transport coefficients of charged particles undergoing both inelastic and reactive, non-particle-conserving collisions with a gas of neutral molecules are calculated. Momentum - transfer theory (MTT) has been developed mainly by Robson and collaborators. It has been applied to a single reactive gas and mixtures of reactive gases in electric field only. MTT has also been applied in crossed electric and magnetic fields recently and independently of our work but the reactive collisions were not considered. Consider a swarm of electrons of charge e and mass m moving with velocity rvec v through a neutral gas under the influence of an applied electric rvec E and magnetic rvec B field. The collision processes which we shall investigate are limited to elastic, inelastic and reactive collisions of electrons with gas molecules. Here we interpret reactive collisions as collisions which produce change in number of the swarm particles. Reactive collisions involve creation (ionization by electron impact) or loss (electron attachment) of swarm particles. We consider only single ionization in approximation of the mass ratio m/m 0 0 are masses of electrons and neutral particles, respectively. We assume that the stage of evolution of the swarm is the hydrodynamic limit (HDL). In HDL, the space - time dependence of all properties is carried by the number density n of swarm particles

  15. Whole brain magnetization transfer histogram analysis of pediatric acute lymphoblastic leukemia patients receiving intrathecal methotrexate therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Akira [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto-shi Kyoto 606-8507 (Japan)]. E-mail: yakira@kuhp.kyoto-u.ac.jp; Miki, Yukio [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto-shi Kyoto 606-8507 (Japan)]. E-mail: mikiy@kuhp.kyoto-u.ac.jp; Adachi, Souichi [Department of Pediatrics, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto-shi Kyoto 606-8507 (Japan)]. E-mail: sadachi@kuhp.kyoto-u.ac.jp (and others)

    2006-03-15

    Background and purpose: The purpose of this prospective study was to evaluate the hypothesis that magnetization transfer ratio (MTR) histogram analysis of the whole brain could detect early and subtle brain changes nonapparent on conventional magnetic resonance imaging (MRI) in children with acute lymphoblastic leukemia (ALL) receiving methotrexate (MTX) therapy. Materials and methods: Subjects in this prospective study comprised 10 children with ALL (mean age, 6 years; range, 0-16 years). In addition to conventional MRI, magnetization transfer images were obtained before and after intrathecal and intravenous MTX therapy. MTR values were calculated and plotted as a histogram, and peak height and location were calculated. Differences in peak height and location between pre- and post-MTX therapy scans were statistically analyzed. Conventional MRI was evaluated for abnormal signal area in white matter. Results: MTR peak height was significantly lower on post-MTX therapy scans than on pre-MTX therapy scans (p = 0.002). No significant differences in peak location were identified between pre- and post-chemotherapy imaging. No abnormal signals were noted in white matter on either pre- or post-MTX therapy conventional MRI. Conclusions: This study demonstrates that MTR histogram analysis allows better detection of early and subtle brain changes in ALL patients who receive MTX therapy than conventional MRI.

  16. Measurement of the proton form factor ratio at low momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Moshe [Hebrew Univ. of Jerusalem (Israel)

    2016-08-01

    Experiment E08-007-II measured the proton elastic form factor ratio μGE=GM in the momentum transfer range of Q2 ~ 0.02 - 0.08 GeV2, the lowest ever measured by polarization transfer techniques. The experiment was performed at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, USA during 2012. A polarized electron beam with energies of 1.1, 1.7, and 2.2 GeV was elastically scattered off a polarized solid NH3 target. The asymmetries between the cross section of positive and negative helicity states of the beam were determined. These asymmetries can be used to determine the form factor ratio. In this thesis, we present the asymmetry analysis of the experiment, discuss the main challenges and show preliminary results for part of the data. Preliminary asymmetries indicate an increase in the form factor ratio above unity. However, a complete analysis is required before any conclusion can be made. Further analysis is ongoing, and final asymmetry results and form factor extraction is expected during 2017. We also present first results for 14N asymmetries for elastic and quasi-elastic scattering. The measured asymmetries are in agreement with the shell model approximation, within the low accuracy of the measurement. A change in the asymmetry sign between the elastic and the quasi-elastic processes is seen, and should motivate further theoretical studies. These experimental asymmetries will also be useful for systematic studies of other experiments using polarized NH3 targets.

  17. Momentum transfer to rotating magnetized plasma from gun plasma injection

    International Nuclear Information System (INIS)

    Shamim, Imran; Hassam, A. B.; Ellis, R. F.; Witherspoon, F. D.; Phillips, M. W.

    2006-01-01

    Numerical simulations are carried out to investigate the penetration and momentum coupling of a gun-injected plasma slug into a rotating magnetized plasma. An experiment along these lines is envisioned for the Maryland Centrifugal Experiment (MCX) [R. F. Ellis et al., Phys. Plasmas 8, 2057 (2001)] using a coaxial plasma accelerator gun developed by HyperV Technologies Corp. [F. D. Witherspoon et al., Bull. Am. Phys. Soc. 50, LP1 87 (2005)]. The plasma gun would be located in the axial midplane and fired off-axis into the rotating MCX plasma annulus. The numerical simulation is set up so that the initial momentum in the injected plasma slug is of the order of the initial momentum of the target plasma. Several numerical firings are done into the cylindrical rotating plasma. Axial symmetry is assumed. The slug is seen to penetrate readily and deform into a mushroom, characteristic of interchange deformations. It is found that up to 25% of the momentum in the slug can be transferred to the background plasma in one pass across a cylindrical chord. For the same initial momentum, a high-speed low density slug gives more momentum transfer than a low-speed high density slug. Details of the numerical simulations and a scaling study are presented

  18. The vortex structure and flux creep within superconducting permanent-magnet high aspect-ratio discs

    International Nuclear Information System (INIS)

    Watson, J.H.P.; Younas, I.

    1997-01-01

    Inhomogeneous type II superconducting discs magnetized by an applied field will retain some magnetization when field is switched off so the superconducting disc will behave as a permanent magnet after flux creep has reduced to a low value.This paper examines the superconducting vortex structure within superconducting permanent-magnet high aspect-ratio discs which is consistent with the calculated magnetic field distribution.The discs, with radius R, have the axis along the z-direction and the mid-plane of the disc corresponds to z = 0. These discs with large aspect ratios in the remnant state have a region between radius r l and R where the magnetic field is reversed. Surrounding the line r = r l and z = 0 there is a region where H cl which is in the Meissner state. Near r l the vortex lines are strongly curved. For radii r l vortex lines creep to larger values of r. For radii r > r l vortex lines creep to smaller values of r, meet at r l with vortex lines of opposite sign and form a continuous loop which decreases in size and is finally annihilated in the Meissner region. Flux creep induces lossless currents in the Meissner region. (author)

  19. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z

    2004-10-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger.

  20. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    International Nuclear Information System (INIS)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z.

    2004-01-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger

  1. Orientation of X Lines in Asymmetric Magnetic Reconnection-Mass Ratio Dependency

    Science.gov (United States)

    Liu, Yi-Hsin; Hesse, M.; Kuznetsova, M.

    2015-01-01

    Using fully kinetic simulations, we study the X line orientation of magnetic reconnection in an asymmetric configuration. A spatially localized perturbation is employed to induce a single X line, which has sufficient freedom to choose its orientation in three-dimensional systems. The effect of ion to electron mass ratio is investigated, and the X line appears to bisect the magnetic shear angle across the current sheet in the large mass ratio limit. The orientation can generally be deduced by scanning through the corresponding 2-D simulations to find the reconnection plane that maximizes the peak reconnection electric field. The deviation from the bisection angle in the lower mass ratio limit is consistent with the orientation shift of the most unstable linear tearing mode in an electron-scale current sheet.

  2. The progress in diagnostic imaging for staging of bladder and prostate cancer. Endorectal magnetic resonance imaging and magnetization transfer contrast

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Hayashi, Norio; Yanagawa, Makoto; Kawamura, Juichi; Kobayashi, Shigeki; Takeda, Kan; Sugimura, Yoshiki

    1999-01-01

    We retrospectively studied the staging accuracy of endorectal magnetic resonance imaging (MRI) in comparison with transrectal ultrasound examination (TRUS) for 71 localized bladder cancers and 19 localized prostate cancers (PC) radically resected. The accuracy of clinical staging for bladder cancer in endorectal MRI and TRUS was 85.9% and 69.2%, respectively. The presence or absence of the continuity of submucosal enhancement on T2-weighted MRI images could be useful for the staging of bladder cancer. The accuracy of the seminal vesicular invasion for prostate cancer in endorectal MRI and TRUS was 95% and 63%, respectively. To determine whether magnetization transfer contrast (MTC) provides additional information in the diagnosis of prostate cancer, the magnetization transfer ratios (MTRs) were calculated in 22 patients with PC, 5 with benign prostatic hyperplasia (BPH) and 4 controls. The mean MTR in the peripheral zone of the normal prostate (8.0%±3.4 [standard deviation]) showed a statistically significant decrease relative to that in the inner zone of the normal prostate (27.4%±3.4, p<0.01), BPH (25.5%±3.7, p<0.01), pre-treatment PC (30.6%±5.9, p<0.01), and PC after hormonal therapy (20.3%±6.3, p<0.01). The mean MTR in pre-treatment PC was significantly higher than that in BPH, or in PC after hormonal therapy (p<0.01). MTC was considered to be useful for conspicuity of prostate cancer lesion. (author)

  3. Heat transfer control in a plane magnetic fluid layer with a free surface

    International Nuclear Information System (INIS)

    Bashtovoi, V.G.; Pogirnitskaya, S.G.; Reks, A.G.

    1993-01-01

    The heat transfer mechanisms that are specific to a magnetic liquid have been already investigated extensively. The high sensitivity of the free magnetic liquid surface to the external magnetic field introduces a new feature into the heat transfer process. In the present work, the authors have investigated the possibility of controlling the heat transfer through the phenomenon of magnetic liquid surface instability in a uniform magnetic field. The conditions for heat transfer through a chamber, partially filled with a magnetic liquid, are governed by the characteristics of the free liquid surface and by its stability and development in the supercritical magnetic fields. The authors consider a model two-dimensional problem of heat transfer through a two-layer medium consisting of horizontally situated immiscible layers of magnetic and nonmagnetic liquids with given thermal conductivities. In the absence of an external magnetic field, the interface of the liquids represents a plane surface. In fields which exceed the critical magnitude, the interface is deformed along the wave. As the field intensity is increased, the amplitude of interface distortion becomes larger. The two-dimensional shape of the free magnetic liquid surface may be realized experimentally using two plane layers of magnetic and nonmagnetic liquids in a uniform magnetic field tangent to the interface of the component layers. 7 refs., 9 figs

  4. Energy transfers and magnetic energy growth in small-scale dynamo

    KAUST Repository

    Kumar, Rohit Raj; Verma, Mahendra K.; Samtaney, Ravi

    2013-01-01

    In this letter we investigate the dynamics of magnetic energy growth in small-scale dynamo by studying energy transfers, mainly energy fluxes and shell-to-shell energy transfers. We perform dynamo simulations for the magnetic Prandtl number Pm = 20

  5. Ratio-metric sensor to detect riboflavin via fluorescence resonance energy transfer with ultrahigh sensitivity

    Science.gov (United States)

    Wang, Jilong; Su, Siheng; Wei, Junhua; Bahgi, Roya; Hope-Weeks, Louisa; Qiu, Jingjing; Wang, Shiren

    2015-08-01

    In this paper, a novel fluorescence resonance energy transfer (FRET) ration-metric fluorescent probe based on heteroatom N, S doped carbon dots (N, S-CDs) was developed to determine riboflavin in aqueous solutions. The ratio of two emission intensities at different wavelengths is applied to determine the concentration of riboflavin (RF). This method is more effective in reducing the background interference and fluctuation of diverse conditions. Therefore, this probe obtains high sensitivity with a low limit of detection (LOD) of 1.9 nM (0.7 ng/ml) which is in the highest level of all riboflavin detection approaches and higher than single wavelength intensity detection (1.9 μM). In addition, this sensor has a high selectivity of detecting riboflavin in deionized water (pH=7) with other biochemical like amino acids. Moreover, riboflavin in aqueous solution is very sensitive to sunlight and can be degraded to lumiflavin, which is toxic. Because the N, S doped carbon dots cannot serve as an energy donor for N, S doped carbon dots and lumiflavin system, this system makes it easy to determine whether the riboflavin is degraded or not, which is first to be reported. This platform may provide possibilities to build a new and facile fluorescence resonance energy transfer based sensor to detect analytes and metamorphous analytes in aqueous solution.

  6. Modulation of spin transfer torque amplitude in double barrier magnetic tunnel junctions

    Science.gov (United States)

    Clément, P.-Y.; Baraduc, C.; Ducruet, C.; Vila, L.; Chshiev, M.; Diény, B.

    2015-09-01

    Magnetization switching induced by spin transfer torque is used to write magnetic memories (Magnetic Random Access Memory, MRAM) but can be detrimental to the reading process. It would be quite convenient therefore to modulate the efficiency of spin transfer torque. A solution is adding an extra degree of freedom by using double barrier magnetic tunnel junctions with two spin-polarizers, with controllable relative magnetic alignment. We demonstrate, for these structures, that the amplitude of in-plane spin transfer torque on the middle free layer can be efficiently tuned via the magnetic configuration of the electrodes. Using the proposed design could thus pave the way towards more reliable read/write schemes for MRAM. Moreover, our results suggest an intriguing effect associated with the out-of-plane (field-like) spin transfer torque, which has to be further investigated.

  7. Modulation of spin transfer torque amplitude in double barrier magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Clément, P.-Y.; Baraduc, C.; Chshiev, M.; Diény, B.; Ducruet, C.; Vila, L.

    2015-01-01

    Magnetization switching induced by spin transfer torque is used to write magnetic memories (Magnetic Random Access Memory, MRAM) but can be detrimental to the reading process. It would be quite convenient therefore to modulate the efficiency of spin transfer torque. A solution is adding an extra degree of freedom by using double barrier magnetic tunnel junctions with two spin-polarizers, with controllable relative magnetic alignment. We demonstrate, for these structures, that the amplitude of in-plane spin transfer torque on the middle free layer can be efficiently tuned via the magnetic configuration of the electrodes. Using the proposed design could thus pave the way towards more reliable read/write schemes for MRAM. Moreover, our results suggest an intriguing effect associated with the out-of-plane (field-like) spin transfer torque, which has to be further investigated

  8. Correlation development of natural convection heat transfer in consideration of aspect ratio change and coolant boiling

    International Nuclear Information System (INIS)

    Park, L. J.; Cho, Y. L.; Kang, K. H.; Kim, S. B.; Kim, H. D.; Cho, J. S.; Jung, C. H.

    1999-01-01

    A new correlation on natural convection heat transfer with crust formation in the molten metal pool has been developed in consideration of coolant boiling effect and of aspect ratio change by an increase in crust thickness. Two test results of the convection cooling case, natural and forced convection cooling cases, and of the boiling case were used in the present study. The experimental results have shown that the Nusselt number of the case with boiling condition in the molten metal pool is greater than that of the case with non-boiling condition at the same Rayleigh number. Even though the Rayleigh number rapidly decreases due to an increase of the crust thickness, the Nusselt number does not rapidly decrease because of the aspect ratio effect. From the experimental results, the new correlation between the Nusselt number and Rayleigh number in the molten metal pool with the crust formation has been developed as Nu 0.051(Ra) 1/3 (AR) . 0 .2441 (Φ) 0.025 using Globe and Dropkin correlation

  9. Pressure drop and heat transfer of lithium single-phase flow under transverse magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Aritomi, Masanori; Inoue, Akira; Matsuzaki, Mitsuo

    1996-01-01

    Pressure drop and heat transfer characteristics of a lithium single-phase flow in a rectangular channel was investigated experimentally in the presence of a magnetic field. Friction loss coefficient under non-magnetic field and skin friction coefficient under magnetic field agreed well with the Blasius formula and a simple analytical expression, respectively. Nusselt number under non-magnetic field was slightly lower than the correlation by Hartnett and Irvine. Heat transfer was enhanced by increasing magnetic field above the Hartmann number of about 200. (author)

  10. On the inverse transfer of (non-)helical magnetic energy in a decaying magnetohydrodynamic turbulence

    Science.gov (United States)

    Park, Kiwan

    2017-12-01

    In our conventional understanding, large-scale magnetic fields are thought to originate from an inverse cascade in the presence of magnetic helicity, differential rotation or a magneto-rotational instability. However, as recent simulations have given strong indications that an inverse cascade (transfer) may occur even in the absence of magnetic helicity, the physical origin of this inverse cascade is still not fully understood. We here present two simulations of freely decaying helical and non-helical magnetohydrodynamic (MHD) turbulence. We verified the inverse transfer of helical and non-helical magnetic fields in both cases, but we found the underlying physical principles to be fundamentally different. In the former case, the helical magnetic component leads to an inverse cascade of magnetic energy. We derived a semi-analytic formula for the evolution of large-scale magnetic field using α coefficient and compared it with the simulation data. But in the latter case, the α effect, including other conventional dynamo theories, is not suitable to describe the inverse transfer of non-helical magnetic energy. To obtain a better understanding of the physics at work here, we introduced a 'field structure model' based on the magnetic induction equation in the presence of inhomogeneities. This model illustrates how the curl of the electromotive force leads to the build up of a large-scale magnetic field without the requirement of magnetic helicity. And we applied a quasi-normal approximation to the inverse transfer of magnetic energy.

  11. Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging.

    Science.gov (United States)

    Wang, Feng; Jiang, Rosie; Takahashi, Keiko; Gore, John; Harris, Raymond C; Takahashi, Takamune; Quarles, C Chad

    2014-11-01

    The purpose of this study is to evaluate the utility of high-resolution non-invasive endogenous high-field MRI methods for the longitudinal structural and quantitative assessments of mouse kidney disease using the model of unilateral ureter obstruction (UUO). T1-weighted, T2-weighted and magnetization transfer (MT) imaging protocols were optimized to improve the regional contrast in mouse kidney. Conventional T1 and T2 weighted images were collected in UUO mice on day 0 (~3h), day 1, day 3 and day 6 after injury, on a 7 T small animal MRI system. Cortical and medullary thickness, corticomedullary contrast and Magnetization Transfer Ratio (MTR) were assessed longitudinally. Masson trichrome staining was used to histologically assess changes in tissue microstructure. Over the course of UUO progression there were significant (prenal cortical and medullary atrophy, cortical-medullary differentiation and MTR changes provide an endogenous, non-invasive and quantitative evaluation of renal morphology and tissue composition during UUO progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Is white matter affected in adolescents with anorexia nervosa? A study using magnetization transfer imaging.

    Science.gov (United States)

    Akgül, Sinem; Öz, Ayşegül; Karlı-Oğuz, Kader; Kanbur, Nuray; Derman, Orhan

    2016-01-01

    The aim of the study was to assess potential changes in structural integrity of the brain in adolescent patients with Anorexia Nervosa (AN) using the magnetization transfer imaging technique and re-evaluating after nutritional rehabilitation was accomplished. Magnetization transfer ratio (MTR) was used for the detection and quantification of histological changes to the white matter of 9 adolescents diagnosed with AN at diagnosis and after weight gain. Using the MTR technique 6 regions were measured: the pons, left cerebellar hemisphere, amygdala, thalamus, corona radiata and white matter adjacent to the left dorsolateral prefrontal cortex. Scans from the patients with AN were also compared with scans from an age-matched subset of 9 healthy controls. Compared with control subjects, the MTR of participants with AN was no different either at the early stages of diagnosis (p=0.62) or after weight recovery (p=0.81). Similarly, comparison of MTR between patients with AN at diagnoses compared with MTR after weight recovery yielded no statistically significant difference (P=0.33). We conclude that MTR was not able to detect any neuropathological alterations in adolescent patients with AN at either diagnosis or after nutritional recovery and the achievement of weight gain.

  13. Integrated intensities and flipping ratios in neutron diffraction by perfect magnetic crystals

    International Nuclear Information System (INIS)

    Guigay, J.P.; Schlenker, M.

    1979-01-01

    A theoretical study of neutron diffraction by perfect magnetic crystals is presented which shows that when the magnetization is perpendicular to the diffraction vector (β- π/2), the dispersion surface is made up of two hyperbolic surfaces corresponding to simple polarization states and the results of the two-beam dynamical theory for non-magnetic crystals can be directly applied. The asymptotic properties of the dispersion surface are of the dispersion surface are also discussed in the more general case (β is not equal to π/2) and an analytical treatment of the kinematical limit is presented. Integrated intensities and flipping ratios outside this limit can only be calculated numerically. It is shown that the wave fields defined by the different points of the dispersion surface are polarized in the (g, B 0 ) plane; this is a generalization of the fact that they are (+-) states with respect to B 0 in the simple case (β=π/2). (UK)

  14. Leptothrix sp sheaths modified with iron oxide particles: Magnetically responsive, high aspect ratio functional material

    Czech Academy of Sciences Publication Activity Database

    Šafařík, Ivo; Angelova, R.; Baldíková, Eva; Pospišková, K.; Šafaříková, Miroslava

    2017-01-01

    Roč. 71, FEB (2017), s. 1342-1346 ISSN 0928-4931 R&D Projects: GA ČR(CZ) GA14-11516S; GA MŠk(CZ) LD14075 Institutional support: RVO:67179843 Keywords : removal * Leptothrix * Magnetic modification * Iron oxide * High aspect ratio material Subject RIV: EI - Biotechnology ; Bionics OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 4.164, year: 2016

  15. The magnetization transfer effect in brain studies by 1.5 T magnetic resonance system. When the radiographer should apply it?

    International Nuclear Information System (INIS)

    Ribeiro, M. Margarida; Farinha, Sara; Costa, Joana; Mauricio, J. Cruz; O' Neill, J. Goyri

    2011-01-01

    Purpose: The Magnetization Transfer (MT) obtained by applying a pre-saturation pulse is, in Magnetic Resonance Imaging (MRI), a technique that allows for additional enhancement of lesions on conventional T1 images after contrast administration. This study aims to assess the effectiveness of the technique measuring how MT could improve image quality and diagnostic values through the enhancement of lesions. Methods: Thirteen T1-weighted spin-echo (SE) sequences, obtained by the 1.5 T system after contrast media injection, were analyzed with and without MT. The contrast-to-noise ratio (CNR), as well as the signal-to-noise ratio (SNR) variables were compared in all sequences, according to the reference structures: lateral ventricles, white matter, gray matter, caudate nucleus and internal capsule. The MT ratio average was calculated using the ANOVA scale in order to assess the CNR and the magnetization transfer effect (MTE) for the different lesions and for both sequences (with and without MT). For the assessment of the flow artifact, clinical experts applied a Likert scale with 5 points. Results: For CNR values, the differences between conventional and MT-pulsed images were significant (Student t testp 0,05). Conclusion: In identical conditions of acquisition, the MT does not produce significant differences in the enhancement of lesions, however, it allows a greater capacity to detect the multiple sclerosis plaques, comparing structures around basal nucleus versus gray and white matter.

  16. Impact of the Residual Resistivity Ratio on the Stability of Nb$_{3}$Sn Magnets

    CERN Document Server

    Bordini, B; Oberli, L; Rossi, L; Takala, E

    2012-01-01

    The CERN Large Hadron Collider (LHC) is envisioned to be upgraded in 2020 to increase the luminosity of the machine. The major upgrade will consist in replacing the NbTi quadrupole magnets of the interaction regions with larger aperture magnets. The Nb$_{3}$Sn technology is the preferred option for this upgrade. The critical current density Jc of Nb$_{3}$Sn strands have reached sufficiently high values (in excess of 3000 A/mm2 at 12 T and 4.2 K) allowing larger aperture/stronger field magnets. Nevertheless, such large Jc values may cause magneto-thermal instabilities that can drastically reduce the conductor performance by quenching the superconductor prematurely. In Nb$_{3}$Sn magnets, a relevant parameter for preventing premature quenches induced by magneto-thermal instabilities is the Residual Resistivity Ratio (RRR) of the conductor stabilizing copper. An experimental and theoretical study was carried out to investigate how much the value of the RRR affects the magnet stability and to identify the proper ...

  17. Five-dimensional rotating black hole in a uniform magnetic field: The gyromagnetic ratio

    International Nuclear Information System (INIS)

    Aliev, A.N.; Frolov, Valeri P.

    2004-01-01

    In four-dimensional general relativity, the fact that a Killing vector in a vacuum spacetime serves as a vector potential for a test Maxwell field provides one with an elegant way of describing the behavior of electromagnetic fields near a rotating Kerr black hole immersed in a uniform magnetic field. We use a similar approach to examine the case of a five-dimensional rotating black hole placed in a uniform magnetic field of configuration with biazimuthal symmetry that is aligned with the angular momenta of the Myers-Perry spacetime. Assuming that the black hole may also possess a small electric charge we construct the five-vector potential of the electromagnetic field in the Myers-Perry metric using its three commuting Killing vector fields. We show that, like its four-dimensional counterparts, the five-dimensional Myers-Perry black hole rotating in a uniform magnetic field produces an inductive potential difference between the event horizon and an infinitely distant surface. This potential difference is determined by a superposition of two independent Coulomb fields consistent with the two angular momenta of the black hole and two nonvanishing components of the magnetic field. We also show that a weakly charged rotating black hole in five dimensions possesses two independent magnetic dipole moments specified in terms of its electric charge, mass, and angular momentum parameters. We prove that a five-dimensional weakly charged Myers-Perry black hole must have the value of the gyromagnetic ratio g=3

  18. Pulsed magnetization transfer imaging with body coil transmission at 3 Tesla: feasibility and application.

    Science.gov (United States)

    Smith, Seth A; Farrell, Jonathan A D; Jones, Craig K; Reich, Daniel S; Calabresi, Peter A; van Zijl, Peter C M

    2006-10-01

    Pulsed magnetization transfer (MT) imaging has been applied to quantitatively assess brain pathology in several diseases, especially multiple sclerosis (MS). To date, however, because of the high power deposition associated with the use of short, rapidly repeating MT prepulses, clinical application has been limited to lower field strengths. The contrast-to-noise ratio (CNR) of MT is limited, and this method would greatly benefit from the use of higher magnetic fields and phased-array coil reception. However, power deposition is proportional to the square of the magnetic field and scales with coil size, and MT experiments are already close to the SAR limit at 1.5T even when smaller transmit coils are used instead of the body coil. Here we show that these seemingly great obstacles can be ameliorated by the increased T(1) of tissue water at higher field, which allows for longer maintenance of sufficiently high saturation levels while using a reduced duty cycle. This enables a fast (5-6 min) high-resolution (1.5 mm isotropic) whole-brain MT acquisition with excellent anatomical visualization of gray matter (GM) and white matter (WM) structures, and even substructures. The method is demonstrated in nine normal volunteers and five patients with relapsing remitting MS (RRMS), and the results show a clear delineation of heterogeneous lesions.

  19. Active transfer of poloidal magnetic energy during plasma disruptions in J-TEXT

    International Nuclear Information System (INIS)

    Zhang, Ming; Zhang, Jun; Rao, Bo; Chen, Zhongyong; Li, Xiaolong; Xu, Wendi; Pan, Yuan; Yu, Kexun

    2016-01-01

    Highlights: • An alternative plasma disruption mitigation method by transferring partial poloidal magnetic energy out of the vacuum vessel has been presented in this paper. • This method can reduced the magnetic energy dissipated inside the vacuum vessel during disruption and mitigated the disruption damage. • This method has been experimentally verified in J-TEXT with an experiment system set up. • According to the experimental results, the magnetic energy dissipated inside the vacuum vessel during disruption can be reduced by 20% or more and the loop voltage can be reduced by 58%. - Abstract: The magnitude of the damaging effects of plasma disruptions on vacuum vessel (VV) components increases with the thermal energy and poloidal magnetic energy dissipated inside the VV. This study focuses on an alternative method, by which partial poloidal magnetic energy is transferred out of the VV. The quantity of the poloidal magnetic energy dissipated inside the VV (W_d_i_s) can be reduced with this method, and the damaging effects can be mitigated. Partial magnetic energy is transferred based on magnetic coupling by a group of energy transfer coils (ETCs) that are coupled with the plasma current. This method, which is called magnetic energy transfer (MET), has been experimentally verified in J-TEXT. W_d_i_s can be reduced by approximately 20%, and the loop voltage can be reduced by 58%. MET is established as a novel, promising, and effective plasma disruption mitigation method.

  20. Spin–transfer torque oscillator in magnetic tunneling junction with short–wavelength magnon excitation

    Directory of Open Access Journals (Sweden)

    Shizhu Qiao

    2018-05-01

    Full Text Available Bloch–Bloembergen–Slonczewski (BBS equation is established by extending Bloch–Bloembergen equation, and it is used to study magnetization oscillation in the free magnetic layer of a magnetic tunneling junction. Since both short–wavelength magnon excitation and spin–transfer torque are taken into account in the BBS equation, it is distinguished from Landau–Lifshitz–Gilbert–Slonczewski equation. The macro–spin BBS model predicts that the transverse relaxation time in free magnetic layer should be long enough, as compared with the longitudinal relaxation time, to achieve stable magnetization oscillation for spin–transfer torque oscillator application. Moreover, field–like torque favors the tolerance of fast transverse relaxation, which makes magnetic tunneling junction a better choice than spin valve for the spin–transfer torque oscillator application.

  1. Fundamental study on gene transfer utilizing magnetic force and jet injector

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, T.; Nakagami, H.; Akiyama, Y.; Nishjima, S. [Osaka University, Osaka (Japan)

    2017-03-15

    Recently, DNA vaccination is attracting attentions as a new therapeutic method for lifestyle diseases and autoimmune diseases. However, its clinical applications are limited because a safe and efficient gene transfer method has not been established yet. In this study, a new method of gene transfer was proposed which utilizes the jet injection and the magnetic transfection. The jet injection is a method to inject medical liquid by momentary high pressure without needle. The injected liquid diffuses in the bio tissue and the endocytosis is considered to be improved by the diffusion. The magnetic transfection is a method to deliver the conjugates of plasmid DNA and magnetic particles to the desired site by external magnetic field. It is expected that jet injection of the conjugates causes slight membrane disruptions and the traction of the conjugates by magnetic field induces the efficient gene transfer. In conclusion, the possibility of improvement of the gene expression by the combination of jet injection and magnetic transfection was confirmed.

  2. Fundamental study on gene transfer utilizing magnetic force and jet injector

    International Nuclear Information System (INIS)

    Hasegawa, T.; Nakagami, H.; Akiyama, Y.; Nishjima, S.

    2017-01-01

    Recently, DNA vaccination is attracting attentions as a new therapeutic method for lifestyle diseases and autoimmune diseases. However, its clinical applications are limited because a safe and efficient gene transfer method has not been established yet. In this study, a new method of gene transfer was proposed which utilizes the jet injection and the magnetic transfection. The jet injection is a method to inject medical liquid by momentary high pressure without needle. The injected liquid diffuses in the bio tissue and the endocytosis is considered to be improved by the diffusion. The magnetic transfection is a method to deliver the conjugates of plasmid DNA and magnetic particles to the desired site by external magnetic field. It is expected that jet injection of the conjugates causes slight membrane disruptions and the traction of the conjugates by magnetic field induces the efficient gene transfer. In conclusion, the possibility of improvement of the gene expression by the combination of jet injection and magnetic transfection was confirmed

  3. Magnetization transfer contrast on gradient echo MR imaging of the temporomandibular joint

    International Nuclear Information System (INIS)

    Niitsu, M.; Hirohata, H.; Yoshioka, H.; Anno, I.; Campeau, N.G.; Itai, Y.

    1995-01-01

    Thirty-nine temporomandibular joints (TMJ) from 20 patients with suspected internal derangements were imaged by a 1.5 T MR imager. The on-resonance binomial magnetization transfer contrast (MTC) pulse was applied to gradient echo images with a dual receiver coil (9 s/section). With the use of an opening device, a series of sequential images were obtained at increments of mouth opening and closing. The tissue signal intensities with (Ms) and without (Mo) MTC were measured and subjective image analysis was performed. Compared with the standard images, MTC technique provided selective signal suppression of disks. The average of Ms/Mo ratio of the disks (0.56) was lower than that of the retrodiskal pad (0.79) and of the effusion (0.89). With MTC technique, fluid conspicuity was superior to standard image. However, no significant superiority was found in disk definition subjectively. (orig.)

  4. Survey of studies on the flow and heat transfer of two-component, two-phase flow of liquid metal in magnetic field

    International Nuclear Information System (INIS)

    Kumamaru, Hiroshige

    1980-01-01

    Brief review of the studies on the flow and heat transfer of two-component, two-phase flow of liquid metal in magnetic field is presented. R.J. Thome measured the distribution of void rate, slip ratio and pressure loss for the two-phase flow of NaK-N 2 under vertical magnetic field. The void rate distribution became even and the slip ratio increased with the increasing magnetic field. The experimental results of pressure loss was compared with the calculation by an equation derived from the homogeneous flow model. R.G. Owen et al. made the analytical studies of the MHD friction loss of two phase flow. Michiyoshi et al. made experimental studies on the hydrodynamic local properties of Hg-Ar two-phase flow of slug region in a vertically ascending tube under magnetic field, and Kimi et al. also made studies on the heat transfer of Hg-Ar flow under magnetic field. Saito et al. measured the slip ratio and pressure loss of NaK-N 2 flow. As a whole, it can be said that the average void rate decreases, and its distribution becomes even under magnetic field. The slip ratio increases, and the friction loss factor becomes nearly one. It was hard to make clear the heat transfer characteristics. (Kato, T.)

  5. Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Silver, N.C. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Barker, G.J. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Losseff, N.A. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Gawne-Cain, M.L. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); MacManus, D.G. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Thompson, A.J. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Miller, D.H. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom)

    1997-06-01

    MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30 % units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95 % units, interquartile range 17.25-19.00, P = 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials. (orig.). With 2 figs., 1 tab.

  6. Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosis

    International Nuclear Information System (INIS)

    Silver, N.C.; Barker, G.J.; Losseff, N.A.; Gawne-Cain, M.L.; MacManus, D.G.; Thompson, A.J.; Miller, D.H.

    1997-01-01

    MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30 % units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95 % units, interquartile range 17.25-19.00, P 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials. (orig.). With 2 figs., 1 tab

  7. The effect of a magnetic field on heat transfer in a slotted channel

    International Nuclear Information System (INIS)

    Evtushenko, I.A.; Hua, T.Q.; Kirillov, I.R.; Reed, Claude B.; Sidorenkov, S.S.

    1995-01-01

    The results of numerical and experimental studies of liquid metal heat transfer in slotted channels in a transverse magnetic field are presented. Test results showed an improvement in heat transfer in a straight channel at low and moderate interaction parameter N. The Nusselt number at small N (around 120) was up to twofold higher than in turbulent flow without a magnetic field, the Peclet number being equal. This effect of heat transfer enhancement is caused by the generation and development of large-scale velocity fluctuations close to the heated wall area. Qualitative and quantitative correlations between heat transfer and velocity fluctuation characteristics are presented. (orig.)

  8. Effect of an alternating nonuniform magnetic field on ferrofluid flow and heat transfer in a channel

    International Nuclear Information System (INIS)

    Goharkhah, Mohammad; Ashjaee, Mehdi

    2014-01-01

    Forced convective heat transfer of water based Fe 3 O 4 nanofluid (ferrofluid) in the presence of an alternating non-uniform magnetic field is investigated numerically. The geometry is a two-dimensional channel which is subjected to a uniform heat flux at the top and bottom surfaces. Nonuniform magnetic field produced by eight line source dipoles is imposed on several parts of the channel. Also, a rectangular wave function is applied to the dipoles in order to turn them on and off alternatingly. The effects of the alternating magnetic field strength and frequency on the convective heat transfer are investigated for four different Reynolds numbers (Re=100, 600, 1200 and 2000) in the laminar flow regime. Comparing the results with zero magnetic field case, show that the heat transfer enhancement increases with the Reynolds number and reaches a maximum of 13.9% at Re=2000 and f=20 Hz. Moreover, at a constant Reynolds number, it increases with the magnetic field intensity while an optimum value exists for the frequency. Also, the optimum frequency increases with the Reynolds number. On the other hand, the heat transfer enhancement due to the magnetic field is always accompanied by a pressure drop penalty. A maximum pressure drop increase of 6% is observed at Re=2000 and f=5 Hz which shows that the pressure drop increase is not as significant as the heat transfer enhancement. - Highlights: • An alternating magnetic field is imposed on ferrofluid flow in a heated channel. • Heat transfer is enhanced noticeably compared to the case with no magnetic field. • Heat transfer depends on Reynolds number, magnetic field intensity and frequency. • Optimum frequency is independent of intensity but increases with Reynolds number. • Pressure drop increase is not as significant as the heat transfer enhancement

  9. Wireless energy transfer through non-resonant magnetic coupling

    DEFF Research Database (Denmark)

    Peng, Liang; Breinbjerg, Olav; Mortensen, Asger

    2010-01-01

    could be properly designed to minimize undesired energy dissipation in the source coil when the power receiver is out of the range. Our basic observation paves the way for more flexible design and fabrication of non-resonant mid-range wireless energy transfer systems, thus potentially impacting......We demonstrate by theoretical analysis and experimental verification that mid-range wireless energy transfer systems may take advantage of de-tuned coupling devices, without jeopardizing the energy transfer efficiency. Allowing for a modest de-tuning of the source coil, energy transfer systems...... practical implementations of wireless energy transfer....

  10. Initial study of magnetization transfer contrast MR imaging of the knee at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hiroshi; Echigo, Junko; Niitsu, Mamoru; Anno, Izumi; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Nakai, Toshiharu; Sato, Hiroshi; Tsukamoto, Tetsuji

    1998-10-01

    It has been reported that various image sequences, including magnetization transfer contrast (MTC) were effective in evaluating articular cartilage. It is difficult to identify cartilaginous structures, however, using conventional MR imaging because of low spatial resolution and low signal-to-noise (S/N) ratio. The purpose of the present study was to evaluate the optimal imaging sequences with MTC pulse at 3 T and to assess the feasibility of the clinical application thereof. Five porcine knees were studied using varying imaging parameters (frequency offset, flip angle (FA) and echo time (TE)) combined with off-resonance sinc radiation pulses. The effect of MTC was analyzed by dividing the signal intensity of MTC GRE images by that of conventional GRE images (Ms/Mo). MTC images were obtained with a low specific absorption rate (SAR). With an offset frequency of 1.5 kHz (repetition time/TE/FA=60 ms/8 ms/30 degrees), the mean Ms/Mo of articular cartilage and meniscus was 0.70 and 0.65, respectively. An FA of 20 to 30 degrees and a TE of 11 to 12 ms appear to be optimal parameters at 3 T with MTC pulse because of the higher S/N ratio of cartilage and higher contrast-to-noise ratio of cartilage relative to that of distilled water. These findings suggest that MTC at 3 T may be feasible and effective for assessment of cartilage and meniscus in clinical applications. (author)

  11. Experimental study on heat transfer augmentation of graphene based ferrofluids in presence of magnetic field

    DEFF Research Database (Denmark)

    Sadeghinezhad, Emad; Mehrali, Mohammad; Akhiani, Amir Reza

    2017-01-01

    The effect of a permanent magnetic field on the heat transfer characteristics of hybrid graphene-magnetite nanofluids (hybrid nanofluid) under forced laminar flow was experimentally investigated. For this purpose, a reduced graphene oxide-Fe3O4 was synthesized by using two-dimensional (2D) graphene...... and it shows that the thermal conductivity increased up to 11%. The hybrid nanofluid behaves as a Newtonian fluid with liquid like behavior with superparamagnetic properties as was evident from its magnetic saturation value at 45.9 emu/g. Moreover, the experimental heat-transfer results indicated that the heat...... transfer enhancement of the hybrid nanofluid compared to the control fluid (distilled water) was negligible when no magnetic field was applied. Additionally, the convective heat transfer was significantly improved under the influence of a magnetic field with a maximum enhancement of 82% in terms...

  12. Symmetric Anderson impurity model: Magnetic susceptibility, specific heat and Wilson ratio

    Science.gov (United States)

    Zalom, Peter; Pokorný, Vladislav; Janiš, Václav

    2018-05-01

    We extend the spin-polarized effective-interaction approximation of the parquet renormalization scheme from Refs. [1,2] applied on the symmetric Anderson model by adding the low-temperature asymptotics of the total energy and the specific heat. We calculate numerically the Wilson ratio and determine analytically its asymptotic value in the strong-coupling limit. We demonstrate in this way that the exponentially small Kondo scale from the strong-coupling regime emerges in qualitatively the same way in the spectral function, magnetic susceptibility and the specific heat.

  13. Geometry dependence of magnetic and transport AC losses in Bi-2223/Ag tapes with different aspect ratios

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Luo, X M [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Chen, D X [ICREA and Grup Electromagnetisme, Departament de Fisica, Universitat Autonoma Barcelona, 08193 Bellaterra (Spain); Alamgir, A K M [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Collings, E W [MSE, Ohio State University, Columbus, OH 43210 (United States); Lee, E [MSE, Ohio State University, Columbus, OH 43210 (United States); Sumption, M D [MSE, Ohio State University, Columbus, OH 43210 (United States); Fang, J G [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Yi, H P [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Song, X H [Innova Superconductor Technology Co., Ltd, 7 Rongchang Dongjie, Longsheng Industrial Park, Beijing Economic and Technological Development Area, 100176 (China); Guo, S Q [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Liu, M L [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Xin, Y [Innopower Superconductor Cable Co., Ltd, 7 Rongchang Dongjie, Longsheng Industrial Park, Beijing Economic and Technological Development Area, 100176 (China); Han, Z [Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)

    2004-10-01

    On five Bi-2223/Ag tapes with different aspect ratios from 5 to 26, AC losses have been measured at 77 K while a parallel AC magnetic field or a perpendicular AC magnetic field or a longitudinal AC transport current is applied. It has been found that at any frequency the perpendicular magnetic losses per cycle increase, but the parallel magnetic losses per cycle and the transport losses per cycle decrease as the aspect ratio increases. These experimental results are in accord with theoretical results. Meanwhile, we investigated the geometry dependence of the decay time constant of coupling current and that of full penetration field.

  14. Geometry dependence of magnetic and transport AC losses in Bi-2223/Ag tapes with different aspect ratios

    International Nuclear Information System (INIS)

    Fang, J; Luo, X M; Chen, D X; Alamgir, A K M; Collings, E W; Lee, E; Sumption, M D; Fang, J G; Yi, H P; Song, X H; Guo, S Q; Liu, M L; Xin, Y; Han, Z

    2004-01-01

    On five Bi-2223/Ag tapes with different aspect ratios from 5 to 26, AC losses have been measured at 77 K while a parallel AC magnetic field or a perpendicular AC magnetic field or a longitudinal AC transport current is applied. It has been found that at any frequency the perpendicular magnetic losses per cycle increase, but the parallel magnetic losses per cycle and the transport losses per cycle decrease as the aspect ratio increases. These experimental results are in accord with theoretical results. Meanwhile, we investigated the geometry dependence of the decay time constant of coupling current and that of full penetration field

  15. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    International Nuclear Information System (INIS)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish

    2015-01-01

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency

  16. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish [Department of Electronics and Instrumentation Engineering, Institute of Technical Education and Research, Siksha ‘O’ Anushandhan University, Bhubaneswar 751030 (India)

    2015-09-28

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.

  17. Magnetic and structural characterization of Mo-Hitperm alloys with different Fe/Co ratio

    Energy Technology Data Exchange (ETDEWEB)

    Conde, C.F., E-mail: conde@us.es [Departamento de Fisica de la Materia Condensada, ICMSE-CSIC, Universidad de Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Borrego, J.M.; Blazquez, J.S.; Conde, A. [Departamento de Fisica de la Materia Condensada, ICMSE-CSIC, Universidad de Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Svec, P.; Janickovic, D. [Department of Metal Physics, Institute of Physics, Slovak Academy of Sciences, Dubravska Cesta 9, 845 11 Bratislava (Slovakia)

    2011-02-03

    Research highlights: > Nanocrystallization kinetics results based on isothermal (TMG) and non-isothermal (DSC) experiments agree describing a strongly inhibited grain growth process. > The crystalline volume fraction at the end of the nanocrystallization process is practically not affected with the increase of Co in the alloy, although it is lower than in the corresponding Co free alloy. The lattice parameter and the crystal size of the {alpha}-FeCo(Mo) phase nanocrystals decreases as the Co content in the alloy increases. > Moessbauer spectra were analyzed in the frame of three different contributions: pure crystalline, interface and amorphous contribution. Comparison between TEM, XRD and Moessbauer data indicates that some Mo could be present inside the nanocrystals. > Changing the Fe/Co ratio allows to increase the Curie temperature of the amorphous alloys for these compositions between room temperature and {approx}800 K, and therefore, allows tuning the temperature at which the maximum magnetocaloric effect takes place opening a possibility for these alloys as potential low cost magnetic refrigerants. - Abstract: The influence of the Co content on the microstructure and magnetic behaviour of a series of amorphous and nanocrystalline (FeCo){sub 79}Mo{sub 8}Cu{sub 1}B{sub 12} alloys is reported. Changes in the magnetic properties provoked by the microstructural evolution upon different thermal treatments of as-cast samples are analyzed as well. Kinetics of nanocrystallization process can be described by an isokinetic approach. As the Co content in the alloy increases, the Curie temperature of the amorphous as-cast samples increases while the crystallization onset temperature decreases. The crystalline volume fraction as well as the mean grain size of the nanocrystals at the end of the nanocrystallization process are slightly higher for the lowest Co content alloy but smaller than in similar Hitperm Mo-free alloys. The average magnetic field and the average isomer

  18. Passive Shielding Effect on Space Profile of Magnetic Field Emissions for Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2015-01-01

    Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has...... fields for wireless power transfer for vehicle applications....

  19. Helium II heat transfer in LHC magnets : polyimide cable insulation

    NARCIS (Netherlands)

    Winkler, Tiemo

    2017-01-01

    Today’s large particle accelerators like the LHC at CERN are using superconducting materials as a construction material for magnets. These magnets need to be cooled constantly to temperatures below the critical surface of the superconducting material. In the LHC this is achieved by using liquid

  20. Measurements of the Proton Elastic-Form-Factor Ratio μpGEp/GMp at Low Momentum Transfer

    International Nuclear Information System (INIS)

    Ron, G.; Piasetzky, E.; Pomerantz, I.; Shneor, R.; Glister, J.; Lee, B.; Choi, Seonho; Kang, H.; Oh, Y.; Song, J.; Yan, X.; Allada, K.; Dutta, C.; Armstrong, W.; Meziani, Z.-E.; Yao, H.; Arrington, J.; Solvignon, P.; Beck, A.; May-Tal Beck, S.

    2007-01-01

    High-precision measurements of the proton elastic form-factor ratio, μ p G E p /G M p , have been made at four-momentum transfer, Q 2 , values between 0.2 and 0.5 GeV 2 . The new data, while consistent with previous results, clearly show a ratio less than unity and significant differences from the central values of several recent phenomenological fits. By combining the new form-factor ratio data with an existing cross-section measurement, one finds that in this Q 2 range the deviation from unity is primarily due to G E p being smaller than expected

  1. Magnetization transfer changes of grey and white matter in Parkinson's disease

    International Nuclear Information System (INIS)

    Tambasco, N.; Mancini, M.L.; Paciaroni, M.; Gallai, V.; Pelliccioli, G.P.; Chiarini, P.; Leone, F.; Montanari, G.E.

    2003-01-01

    Since the attempt to evidence structural brain damage in Parkinson's disease (PD) by conventional magnetic resonance imaging (MRI) is usually disappointing, we have investigated whether the magnetization transfer ratio (MTR) can reflect changes in grey and white matter of PD patients. MTR was quantified in 44 regions of interest (ROIs) in both grey and white matter of 11 non-demented PD patients, ranging from 2 to 4 on the Hoehn and Yahr Scale, and eight age-matched healthy subjects. MTR differences between patients and controls were found in the supratentorial white matter and in the brainstem. In particular, lower MTR values were found in the paraventricular white matter of PD patients (p < 0.05) while no differences were observed in corpus callosum, frontal, parietal, occipital lobes or centrum semiovalis. Lower MTR values were found in substantia nigra (p < 0.001), red nucleus (p < 0.05) and pons (p < 0.05) of the patient group. No differences were discovered in basal ganglia and thalamus. These findings suggest that MTR measurements in the paraventricular white matter and brainstem may help to recognize a marker for probable PD. (orig.)

  2. Boiling Heat Transfer Mechanisms in Earth and Low Gravity: Boundary Condition and Heater Aspect Ratio Effects

    Science.gov (United States)

    Kim, Jungho

    2004-01-01

    Boiling is a complex phenomenon where hydrodynamics, heat transfer, mass transfer, and interfacial phenomena are tightly interwoven. An understanding of boiling and critical heat flux in microgravity environments is of importance to space based hardware and processes such as heat exchange, cryogenic fuel storage and transportation, electronic cooling, and material processing due to the large amounts of heat that can be removed with relatively little increase in temperature. Although research in this area has been performed in the past four decades, the mechanisms by which heat is removed from surfaces in microgravity are still unclear. Recently, time and space resolved heat transfer data were obtained in both earth and low gravity environments using an array of microheaters varying in size between 100 microns to 700 microns. These heaters were operated in both constant temperature as well as constant heat flux mode. Heat transfer under nucleating bubbles in earth gravity were directly measured using a microheater array with 100 m resolution operated in constant temperature mode with low and high subcooled bulk liquid along with images from below and from the side. The individual bubble departure diameter and energy transfer were larger with low subcooling but the departure frequency increased at high subcooling, resulting in higher overall heat transfer. The bubble growth for both subcoolings was primarily due to energy transfer from the superheated liquid layer relatively little was due to wall heat transfer during the bubble growth process. Oscillating bubbles and sliding bubbles were also observed in highly subcooled boiling. Transient conduction and/or microconvection was the dominant heat transfer mechanism in the above cases. A transient conduction model was developed and compared with the experimental data with good agreement. Data was also obtained with the heater array operated in a constant heat flux mode and measuring the temperature distribution across

  3. Technology transfer for industrial production of superconducting magnets for the RHIC project at BNL

    International Nuclear Information System (INIS)

    Wanderer, P.; Anerella, M.D.; Greene, A.F.; Kelly, E.; Willen, E.

    1994-01-01

    Industrial production of superconducting magnets for the Relativistic Heavy Ion Collider (RHIC) has begun. The R ampersand D for the magnets was carried out at BNL. Following the award of built-to-print contracts, staff from the laboratory and the vendors worked toward transferring both design principles and practical details to an industrial framework for cost effective production. All magnets made thus far have been acceptable for use in RHIC

  4. Ultrahigh Tunneling-Magnetoresistance Ratios in Nitride-Based Perpendicular Magnetic Tunnel Junctions from First Principles

    Science.gov (United States)

    Yang, Baishun; Tao, Lingling; Jiang, Leina; Chen, Weizhao; Tang, Ping; Yan, Yu; Han, Xiufeng

    2018-05-01

    We report a first-principles study of electronic structures, magnetic properties, and the tunneling-magnetoresistance (TMR) effect of a series of ferromagnetic nitride M4N (M =Fe , Co, Ni)-based magnetic tunnel junctions (MTJs). It is found that bulk Fe4 N reveals a half-metal nature in terms of the Δ1 state. A perpendicular magnetic anisotropy is observed in the periodic system Fe4 N /MgO . In particular, the ultrahigh TMR ratio of over 24 000% is predicted in the Fe4 N /MgO /Fe4N MTJ due to the interface resonance tunneling and relatively high transmission for states of other symmetry. Besides, the large TMR can be maintained with the change of atomic details at the interface, such as the order-disorder interface, the change of thickness of the MgO barrier, and different in-plane lattice constants of the MTJ. The physical origin of the TMR effect can be well understood by analyzing the band structure and transmission channel of bulk Fe4 N as well as the transmission in momentum space of Fe4 N /MgO /Fe4N . Our results suggest that the Fe4 N /MgO /Fe4N MTJ is a benefit for spintronic applications.

  5. Magnetization Transfer Magnetic Resonance Imaging Noninvasively Detects Renal Fibrosis in Swine Atherosclerotic Renal Artery Stenosis at 3.0 T.

    Science.gov (United States)

    Jiang, Kai; Ferguson, Christopher M; Woollard, John R; Zhu, Xiangyang; Lerman, Lilach O

    2017-11-01

    Renal fibrosis is a useful biomarker for diagnosis and evaluation of therapeutic interventions of renal diseases but often requires invasive testing. Magnetization transfer magnetic resonance imaging (MT-MRI), which evaluates the presence of macromolecules, offers a noninvasive tool to probe renal fibrosis in murine renal artery stenosis (RAS) at 16.4 T. In this study, we aimed to identify appropriate imaging parameters for collagen detection at 3.0 T MRI and to test the utility of MT-MRI in measuring renal fibrosis in a swine model of atherosclerotic RAS (ARAS). To select the appropriate offset frequency, an MT-MRI study was performed on a phantom containing 0% to 40% collagen I and III with offset frequencies from -1600 to +1600 Hz and other MT parameters empirically set as pulse width at 16 milliseconds and flip angle at 800 degrees. Then selected MT parameters were used in vivo on pigs 12 weeks after sham (n = 8) or RAS (n = 10) surgeries. The ARAS pigs were fed with high-cholesterol diet to induce atherosclerosis. The MT ratio (MTR) was compared with ex vivo renal fibrosis measured using Sirius-red staining. Offset frequencies at 600 and 1000 Hz were selected for collagen detection without direct saturation of free water signal, and subsequently applied in vivo. The ARAS kidneys showed mild cortical and medullary fibrosis by Sirius-red staining. The cortical and medullary MTRs at 600 and 1000 Hz were both increased. Renal fibrosis measured ex vivo showed good linear correlations with MTR at 600 (cortex: Pearson correlation coefficient r = 0.87, P 3.0 T. Therefore, MT-MRI may potentially be clinically applicable and useful for detection and monitoring of renal pathology in subjects with RAS.

  6. Optic nerve magnetisation transfer ratio after acute optic neuritis predicts axonal and visual outcomes.

    Directory of Open Access Journals (Sweden)

    Yejun Wang

    Full Text Available Magnetisation transfer ratio (MTR can reveal the degree of proton exchange between free water and macromolecules and was suggested to be pathological informative. We aimed to investigate changes in optic nerve MTR over 12 months following acute optic neuritis (ON and to determine whether MTR measurements can predict clinical and paraclinical outcomes at 6 and 12 months. Thirty-seven patients with acute ON were studied within 2 weeks of presentation and at 1, 3, 6 and 12 months. Assessments included optic nerve MTR, retinal nerve fibre layer (RNFL thickness, multifocal visual evoked potential (mfVEP amplitude and latency and high (100% and low (2.5% contrast letter acuity. Eleven healthy controls were scanned twice four weeks apart for comparison with patients. Patient unaffected optic nerve MTR did not significantly differ from controls at any time-point. Compared to the unaffected nerve, affected optic nerve MTR was significantly reduced at 3 months (mean percentage interocular difference = -9.24%, p = 0.01, 6 months (mean = -12.48%, p<0.0001 and 12 months (mean = -7.61%, p = 0.003. Greater reduction in MTR at 3 months in patients was associated with subsequent loss of high contrast letter acuity at 6 (ρ = 0.60, p = 0.0003 and 12 (ρ = 0.44, p = 0.009 months, low contrast letter acuity at 6 (ρ = 0.35, p = 0.047 months, and RNFL thinning at 12 (ρ = 0.35, p = 0.044 months. Stratification of individual patient MTR time courses based on flux over 12 months (stable, putative remyelination and putative degeneration predicted RNFL thinning at 12 months (F(2,32 = 3.59, p = 0.02. In conclusion, these findings indicate that MTR flux after acute ON is predictive of axonal degeneration and visual disability outcomes.

  7. Numerical Study of the Rib Arrangements for Enhancing Heat Transfer in a Two-pass Channel of Large Aspect Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sol; Choi, Seok Min; Sohn, Ho-Seong; Cho, Hyung Hee [Yonsei Univ., Seoul (Korea, Republic of)

    2017-03-15

    The present study investigated the effect of the rib arrangement and a guide vane for enhancing internal cooling of the blade. Two types of rib arrangements were used in the first and second passage in parallel. Aspect ratio of the channel was 5 and a fixed Reynolds number based on hydraulic diameter was 10,000. The attack angle of rib was 60°, rib pitch-to-height ratio (p/e) was 10, and the rib height-to-hydraulic-diameter ratio (e/D{sub n}) was 0.075. The effect of an interaction between Dean vortices and the secondary vortices from the first passage was observed. Overall, the attack angle of rib in the first passage was dominant factor to heat transfer and flow patterns in turning region. Also, the channel with a guide vane showed enhanced heat transfer at the tip surface with reducing flow separation and recirculation.

  8. The magnetization transfer characteristics of human breast tissues: an in vitro NMR study

    Science.gov (United States)

    Callicott, C.; Thomas, J. M.; Goode, A. W.

    1999-05-01

    A series of freshly excised human breast tissues was analysed using a nuclear magnetic resonance spectrometer and then subjected to routine histopathology examination. Tissues comprised normal parenchymal, adipose, fibrocystic, fibroadenoma and malignant types. An inversion-recovery sequence performed both with and without magnetization transfer allowed T1, T1, and values to be obtained. From this information, the magnetization transfer rate constant, K, was calculated for each tissue sample. These data show that T1 provided greater discrimination between neoplasic and normal tissues than did T1. However, neither T1 nor K values provided a means of discriminating between benign and malignant disease.

  9. The magnetization transfer characteristics of human breast tissues: an in vitro NMR study

    International Nuclear Information System (INIS)

    Callicott, C.; Thomas, J.M.; Goode, A.W.

    1999-01-01

    A series of freshly excised human breast tissues was analysed using a nuclear magnetic resonance spectrometer and then subjected to routine histopathology examination. Tissues comprised normal parenchymal, adipose, fibrocystic, fibroadenoma and malignant types. An inversion-recovery sequence performed both with and without magnetization transfer allowed T1, T1 5 , M o and M 5 values to be obtained. From this information, the magnetization transfer rate constant, K, was calculated for each tissue sample. These data show that T1 5 provided greater discrimination between neoplasic and normal tissues than did T1. However, neither T1 5 nor K values provided a means of discriminating between benign and malignant disease. (author)

  10. Heat transfer characteristics of rectangular coolant channels with various aspect ratios in the plasma-facing components under fully developed MHD laminar flow

    International Nuclear Information System (INIS)

    Takase, K.; Hasan, M.Z.

    1995-01-01

    Convective heat transfer in MHD laminar flow through rectangular channels in the plasma-facing components of a fusion reactor has been analyzed numerically to investigate the effects of channel aspect ratio, defined as the ratio of the lengths of the plasma-facing side to the other side. The adverse effect of the nonuniformity of surface heat flus on Nusselt number (Nu) at the plasma-facing side can be alleviated by increasing the aspect ratio of a rectangular duct. At the center and corner of the plasma-facing side of a square duct, the Nu of non-MHD flow are 6.8 and 2.2, respectively, for uniform surface heat flux. In the presence of a strong magnetic field, Nu at the center and corner increases to 22 and 3.6, respectively. However, when the heat flux is highly nonuniform, as in the plasma-facing components, Nu decreases from 22 to 3.1 at the center and from 3.6 to 3.1 at the corner. When the aspect ratio is increased to 4, Nu at the center and corner increase to 5 and 4.7. Along the circumference of a rectangular channel, there are locations where the wall temperature is equal to or less than the bulk coolant temperature, thus making the Nu with conventional definition infinity or negative. The ratio between Nu of MHD flow and Nu of non-MHD flow for various aspect ratios is constant in the region of Hartmann number of more than 200 at least. On the other hand, its ratio increases monotonously with increasing the aspect ratio

  11. Research on Wireless Power Transfer System via Magnetically Coupled Resonance

    Directory of Open Access Journals (Sweden)

    ZHU Meng

    2017-04-01

    Full Text Available In order to extend the transmission distance and improve the transmission efficiency of the traditional wireless power transmission(WPTsystem composed with the transmitting and receiving coil resonators based on magnetic resonance coupling,we proposed an effective method to add a magnetic core between repeating coil and receiving coil based on the single repeating three coils mode. This paper deduced a mathematical expression of the transmission efficiency,and built a model by the circuit theory,and also simulated the transmission system added with the magnetic core between repeating and receiving coil. Then we selected the flat magnetic core for test. At last,we verified the feasibility of the proposal by actual experiment.

  12. Effect of the Hartmann number on phase separation controlled by magnetic field for binary mixture system with large component ratio

    Science.gov (United States)

    Heping, Wang; Xiaoguang, Li; Duyang, Zang; Rui, Hu; Xingguo, Geng

    2017-11-01

    This paper presents an exploration for phase separation in a magnetic field using a coupled lattice Boltzmann method (LBM) with magnetohydrodynamics (MHD). The left vertical wall was kept at a constant magnetic field. Simulations were conducted by the strong magnetic field to enhance phase separation and increase the size of separated phases. The focus was on the effect of magnetic intensity by defining the Hartmann number (Ha) on the phase separation properties. The numerical investigation was carried out for different governing parameters, namely Ha and the component ratio of the mixed liquid. The effective morphological evolutions of phase separation in different magnetic fields were demonstrated. The patterns showed that the slant elliptical phases were created by increasing Ha, due to the formation and increase of magnetic torque and force. The dataset was rearranged for growth kinetics of magnetic phase separation in a plot by spherically averaged structure factor and the ratio of separated phases and total system. The results indicate that the increase in Ha can increase the average size of separated phases and accelerate the spinodal decomposition and domain growth stages. Specially for the larger component ratio of mixed phases, the separation degree was also significantly improved by increasing magnetic intensity. These numerical results provide guidance for setting the optimum condition for the phase separation induced by magnetic field.

  13. Canyon transfer neutron absorber to fissile material ratio analysis. Revision 1

    International Nuclear Information System (INIS)

    Clemmons, J.S.

    1994-01-01

    Waste tank fissile material and non-fissile material estimates are used to evaluate criticality safety for the existing sludge inventory and batches of sludge sent to Extended Sludge Processing (ESP). This report documents the weight ratios of several non-fissile waste constituents to fissile waste constituents from canyon reprocessing waste streams. Weight ratios of Fe, Mn, Al, Mi, and U-238 to fissile material are calculated from monthly loss estimates from the F and H Canyon Low Heat Waste (LHW) and High Heat Waste (HHW) streams. The monthly weight ratios for Fe, Mn and U-238 are then compared to calculated minimum safe weight ratios. Documented minimum safe weight ratios for Al and Ni to fissile material are currently not available. Total mass data for the subject sludge constituents is provided along with scatter plots of the monthly weight ratios for each waste stream

  14. Effect of deformation ratios on grain alignment and magnetic properties of hot pressing/hot deformation Nd-Fe-B magnets

    Science.gov (United States)

    Guo, Zhaohui; Li, Mengyu; Wang, Junming; Jing, Zheng; Yue, Ming; Zhu, Minggang; Li, Wei

    2018-05-01

    The magnetic properties, microstructure and orientation degrees of hot pressing magnet and hot deformation Nd-Fe-B magnets with different deformation ratios have been investigated in this paper. The remanence (Br) and maximum magnetic energy product ((BH)max) were enhanced gradually with the deformation ratio increasing from 0% to 70%, whereas the coercivity (HCj) decreased. The scanning electron microscopy (SEM) images of fractured surfaces parallel to the pressure direction during hot deformation show that the grains tend to extend perpendicularly to the c-axes of Nd2Fe14B grains under the pressure, and the aspect ratios of the grains increase with the increase of deformation ratio. Besides, the compression stress induces the long axis of grains to rotate and the angle (θ) between c-axis and pressure direction decreases. The X-ray diffraction (XRD) patterns reveal that orientation degree improves with the increase of deformation ratio, agreeing well with the SEM results. The hot deformation magnet with a deformation ratio of 70% has the best Br and (BH)max, and the magnetic properties are as followed: Br=1.40 T, HCj=10.73 kOe, (BH)max=42.30 MGOe.

  15. Topology of magnetic flux ropes and formation of fossil flux transfer events and boundary layer plasmas

    Science.gov (United States)

    Lee, L. C.; Ma, Z. W.; Fu, Z. F.; Otto, A.

    1993-01-01

    A mechanism for the formation of fossil flux transfer events and the low-level boundary layer within the framework of multiple X-line reconnection is proposed. Attention is given to conditions for which the bulk of magnetic flux in a flux rope of finite extent has a simple magnetic topology, where the four possible connections of magnetic field lines are: IMF to MSP, MSP to IMF, IMF to IMF, and MSP to MSP. For a sufficient relative shift of the X lines, magnetic flux may enter a flux rope from the magnetosphere and exit into the magnetosphere. This process leads to the formation of magnetic flux ropes which contain a considerable amount of magnetosheath plasma on closed magnetospheric field lines. This process is discussed as a possible explanation for the formation of fossil flux transfer events in the magnetosphere and the formation of the low-latitude boundary layer.

  16. Angular dependence of spin transfer torque on magnetic tunnel junctions with synthetic ferrimagnetic free layer

    International Nuclear Information System (INIS)

    Ichimura, M; Hamada, T; Imamura, H; Takahashi, S; Maekawa, S

    2010-01-01

    Based on a spin-polarized free-electron model, spin and charge transports are analyzed in magnetic tunnel junctions with synthetic ferrimagnetic layers in the ballistic regime, and the spin transfer torque is derived. We characterize the synthetic ferrimagnetic free layer by extending an arbitrary direction of magnetizations of the two free layers forming the synthetic ferrimagnetic free layer. The synthetic ferrimagnetic configuration exerts the approximately optimum torque for small magnetization angle of the first layer relative to that of the pinned layer. For approximately anti-parallel magnetization of the first layer to that of the pinned layer, the parallel magnetization of two magnetic layers is favorable for magnetization reversal rather than the synthetic ferrimagnetic configuration.

  17. Experimental investigation of MHD heat transfer in a vertical round tube affected by transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Melnikov, I.A., E-mail: corpuskula@gmail.com; Sviridov, E.V.; Sviridov, V.G.; Razuvanov, N.G.

    2016-11-15

    Highlights: • Local and averaged heat transfer coefficient are measured. • Free convection influence on MHD-flow is investigated. • The region with the free convection effect of MHD-heat transfer is found. • Temperature low-frequency fluctuations of abnormally high amplitude are detected. • Analysis of the MHD-heat transfer experimental data is performed. - Abstract: The article is devoted to the results of experimental investigation of heat transfer for a downward mercury flow in a vertical round tube in the presence of a transverse magnetic with non-uniform heat flux along the tube circumference.

  18. On the Use of Line Depth Ratios to Measure Starspot Properties on Magnetically Active Stars

    Science.gov (United States)

    O'Neal, Douglas

    2006-07-01

    Photometric and spectroscopic techniques have proven to be effective ways to measure the properties of dark, cool starspots on magnetically active stars. Recently, a technique was introduced using atomic line depth ratios (LDRs) to measure starspot properties. Carefully reproducing this technique using a new set of spectroscopic observations of active stars, we find that the LDR technique encounters difficulties, specifically by overestimating spot temperatures (because the atomic lines blend with titanium oxide absorption in cooler spots) and by not tightly constraining the filling factor of spots. While the use of LDRs for active star studies has great promise, we believe that these concerns need to be addressed before the technique is more widely applied. This paper includes data taken at McDonald Observatory of the University of Texas at Austin.

  19. Relaxed and partially relaxed magnetic equilibria in tight-aspect-ratio tori

    International Nuclear Information System (INIS)

    Browning, P.K.; Clegg, J.R.; Duck, R.C.; Rusbridge, M.G.

    1993-01-01

    Force-free equilibrium magnetic fields in tight-aspect-ratio toroidal configurations are investigated. The study is mainly directed to modelling field configurations in the 'rodomak', a modification to the SPHEX gun-injected spheromak in which a current-carrying rod is inserted along the geometric axis. A family of analytical relaxed states (∇ x B = μB, μ constant) is presented for a torus of rectangular cross section, with boundary conditions allowing for flux embedded in the walls, representing the gun. Numerically calculated fields in SPHEX geometry, with μ profiles relevant to the driven phase of operation, are also given. The dependence of the field configurations and global quantities such as energy, helicity and toroidal current on the controlling parameters (gun flux, gun current and rod current) and geometry is discussed. (author)

  20. Realistic ion optical transfer maps for Super-FRS magnets from numerical field data

    Energy Technology Data Exchange (ETDEWEB)

    Kazantseva, Erika; Boine-Frankenheim, Oliver [Technische Universitaet Darmstadt (Germany)

    2016-07-01

    In large aperture accelerators such as Super-FRS, the non-linearity of the magnetic field in bending elements leads to the non-linear beam dynamics, which cannot be described by means of linear ion optics. Existing non-linear approach is based on the Fourier harmonics formalism and is not working if horizontal aperture is bigger as vertical or vice versa. In Super-FRS dipole the horizontal aperture is much bigger than the vertical. Hence, it is necessary to find a way to create the higher order transfer map for this dipole to accurately predict the particle dynamics in the realistic magnetic fields in the whole aperture. The aim of this work is to generate an accurate high order transfer map of magnetic elements from measured or simulated 3D magnetic field data. Using differential algebraic formalism allows generating transfer maps automatically via numerical integration of ODEs of motion in beam physics coordinates along the reference path. To make the transfer map accurate for all particles in the beam, the magnetic field along the integration path should be represented by analytical function, matching with the real field distribution in the volume of interest. Within this work the steps of high order realistic transfer map production starting from the field values on closed box, covering the volume of interest, will be analyzed in detail.

  1. Fluorescence branching ratios and magnetic tuning of the visible spectrum of SrOH

    Science.gov (United States)

    Nguyen, Duc-Trung; Steimle, Timothy C.; Kozyryev, Ivan; Huang, Meng; McCoy, Anne B.

    2018-05-01

    The magnetic tuning of the low rotational levels in the X ˜ 2Σ+ (0,0,0), A ˜ 2Πr (0,0,0), and B ˜ 2Σ+ (0,0,0) electronic states of strontium hydroxide, SrOH, have been experimentally investigated using high resolution optical field-free and Zeeman spectroscopy of a cold molecular beam sample. The observed Zeeman shifts and splittings are successfully modeled using a traditional effective Hamiltonian approach to account for the interaction between the A ˜ 2Πr and B ˜ 2Σ+ states. The determined magnetic g-factors for the X ˜ 2Σ+ , A ˜ 2Πr , and B ˜ 2Σ+ states are compared to those predicted by perturbation theory. The dispersed fluorescence resulting from laser excitation of rotationally resolved branch features of the 000 B ˜ 2Σ+ ← X ˜ 2Σ+ , 000 A ˜ 2Π3/2 ← X ˜ 2Σ+ and 000 A ˜ 2Π1/2 ← X ˜ 2Σ+ transitions have been recorded and analyzed. The measured fluorescence branching ratios are compared with Franck-Condon calculations. The required bending motion wave functions are derived using a discrete variable representation (DVR) method. Implications for laser slowing and magneto-optical trapping experiments for SrOH are described.

  2. Gating in time domain as a tool for improving the signal-to-noise ratio of beam transfer function measurements

    CERN Document Server

    Oeftiger, U; Caspers, Fritz

    1992-01-01

    For the measurement of Beam Transfer Functions the signal-to-noise ratio is of great importance. In order to get a reasonable quality of the measured data one may apply averaging and smoothing. In the following another technique called time gating to improve the quality of the measurement will be described. By this technique the measurement data are Fourier transformed and then modified in time domain. Tune gating suppresses signal contributions that are correlated to a time interval when no interesting information is expected. Afterivards an inverse Fourier transform leads to data in frequency domain with an improved signal to noise ratio.

  3. Spin transfer torque with spin diffusion in magnetic tunnel junctions

    KAUST Repository

    Manchon, Aurelien; Matsumoto, R.; Jaffres, H.; Grollier, J.

    2012-01-01

    in the metallic layers. We show that spin diffusion mixes the transverse spin current components and dramatically modifies the bias dependence of the effective spin transfer torque. This leads to a significant linear bias dependence of the out-of-plane torque

  4. Interferometric study on the mass transfer in cryogenic distillation under magnetic field

    Science.gov (United States)

    Bao, S. R.; Zhang, R. P.; Y Rong, Y.; Zhi, X. Q.; Qiu, L. M.

    2017-12-01

    Cryogenic distillation has long been used for the mass production of industrial gases because of its features of high efficiency, high purity, and capability to produce noble gases. It is of great theoretical and practical significance to explore methods to improve the mass transfer efficiency in cryogenic distillation. The negative correlation between the susceptibility of paramagnetic oxygen and temperature provides a new possibility of comprehensive utilization of boiling point and susceptibility differences in cryogenic distillation. Starting from this concept, we proposed a novel distillation intensifying method by using gradient magnetic field, in which the magnetic forces enhance the transport of the oxygen molecules to the liquid phase in the distillation. In this study, a cryogenic testbed was designed and fabricated to study the diffusion between oxygen and nitrogen under magnetic field. A Mach-Zehnder interferometer was used to visualize the concentration distribution during the diffusion process. The mass transfer characteristics with and without magnetic field, in the chamber filled with the magnetized medium, were systematically studied. The concentration redistribution of oxygen was observed, and the stable stratified diffusion between liquid oxygen and nitrogen was prolonged by the non-uniform magnetic field. The experimental results show that the magnetic field can efficiently influence the mass transfer in cryogenic distillation, which can provide a new mechanism for the optimization of air separation process.

  5. Magnetization Transfer Effects on the Efficiency of Flow-driven Adiabatic Fast Passage Inversion of Arterial Blood

    OpenAIRE

    Hernandez-Garcia, Luis; Lewis, David P.; Moffat, Bradford; Branch, Craig A.

    2007-01-01

    Continuous arterial spin labeling experiments typically use flow-driven adiabatic fast passage (AFP) inversion of the arterial blood water protons. In this article, we measure the effect of magnetization transfer in blood and how it affects the inversion label. We use modified Bloch equations to model flow-driven adiabatic inversion in the presence of magnetization transfer in blood flowing at velocities from 1 to 30 cm/s in order to explain our findings. Magnetization transfer results in a r...

  6. Magnetic Field Emissions for Ferrite and Non-Ferrite Geometries for Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Minimizing magnetic field emissions to surroundings is one of the most challenging design criteria for wireless power transfer to vehicles. In this paper, concept of division of the emissions into three zones (primary, secondary, and combined zone) in the vertical direction is introduced. For geo......Minimizing magnetic field emissions to surroundings is one of the most challenging design criteria for wireless power transfer to vehicles. In this paper, concept of division of the emissions into three zones (primary, secondary, and combined zone) in the vertical direction is introduced...... for vertical separation between the coils in range of 100-180 mm. It is observed that lower vertical separation results in higher overlapping of the zones and the coils behave as they are effectively placed close to center of air gap. The analysis in this work provides a better understanding of the space...... profile of magnetic field emissions (with and without ferrite) for wireless power transfer to vehicles....

  7. Magnetic electron scattering from deuterium at low-momentum transfer

    International Nuclear Information System (INIS)

    Jones, E.C. Jr.; Bendel, W.L.; Fagg, L.W.; Lindgren, R.A.

    1980-01-01

    The elastic and inelastic cross sections of deuterium for 56.4 MeV electrons scattered at 180 0 , have been measured up to an excitation energy of 19 MeV. The experimental cross sections are compared with those calculated by Miller, by Durand, and by Arenhoevel and Fabian, and also with the sum rules of O'Connell. The results indicate that the contribution of meson exchange currents at this low-momentum transfer is significant

  8. Bifurcation analysis of magnetization dynamics driven by spin transfer

    International Nuclear Information System (INIS)

    Bertotti, G.; Magni, A.; Bonin, R.; Mayergoyz, I.D.; Serpico, C.

    2005-01-01

    Nonlinear magnetization dynamics under spin-polarized currents is discussed by the methods of the theory of nonlinear dynamical systems. The fixed points of the dynamics are calculated. It is shown that there may exist 2, 4, or 6 fixed points depending on the values of the external field and of the spin-polarized current. The stability of the fixed points is analyzed and the conditions for the occurrence of saddle-node and Hopf bifurcations are determined

  9. Bifurcation analysis of magnetization dynamics driven by spin transfer

    Energy Technology Data Exchange (ETDEWEB)

    Bertotti, G. [IEN Galileo Ferraris, Strada delle Cacce 91, 10135 Turin (Italy); Magni, A. [IEN Galileo Ferraris, Strada delle Cacce 91, 10135 Turin (Italy); Bonin, R. [Dipartimento di Fisica, Politecnico di Torino, Corso degli Abbruzzi, 10129 Turin (Italy)]. E-mail: bonin@ien.it; Mayergoyz, I.D. [Department of Electrical and Computer Engineering, University of Maryland, College Park, Maryland 20742 (United States); Serpico, C. [Department of Electrical Engineering, University of Napoli Federico II, via Claudio 21, 80125 Naples (Italy)

    2005-04-15

    Nonlinear magnetization dynamics under spin-polarized currents is discussed by the methods of the theory of nonlinear dynamical systems. The fixed points of the dynamics are calculated. It is shown that there may exist 2, 4, or 6 fixed points depending on the values of the external field and of the spin-polarized current. The stability of the fixed points is analyzed and the conditions for the occurrence of saddle-node and Hopf bifurcations are determined.

  10. Pathological Assessment of Brain White Matter in Relapsing-Remitting MS Patients using Quantitative Magnetization Transfer Imaging

    Directory of Open Access Journals (Sweden)

    Khodarahm Pahlevan

    2011-09-01

    Full Text Available Introduction: Multiple sclerosis (MS is characterized by lesions in the white matter (WM of the central nervous system. Magnetic resonance imaging is the most specific and sensitive method for diagnosis of multiple sclerosis. However, the ability of conventional MRI to show histopathologic heterogeneity of MS lesions is insufficient. Quantitative magnetization transfer imaging (qMTI is a relatively new method to investigate pathologic processes of the brain tissue occurring in MS patients. Material and Methods: Voxel-based analyses allow regional comparisons between groups to be made for the whole brain in a single analysis. This is done by coregistering data from all individual subjects to a reference brain, generally referred to as the "standard space", and then comparing them on a voxel-by-voxel basis. This study aimed to analyze whole-brain quantitative T1 maps, not to find global changes or changes in selected regions, but specifically to investigate the spatial distribution throughout the brain of T1 increases in MS WM with respect to control WM. In this study, 11 healthy controls, 10 relapsing-remitting (RR MS patients and 13 CIS patients were studied using MT-MRI imaging. MT parameters, including magnetization transfer ratio (MTR, magnetization transfer rate between free protons and restricted macromolecular protons, Ksat and longitudinal relaxation times (with and without MT saturation pulse, T1sat and T1free values were evaluated. Results: The results showed that, at a group level, there is widespread involvement of WM throughout the brain in CIS MS and especially in RRMS, where a significant T1 increase was found in 15.58% of WM voxels (normals < RR. Discussion and Conclusion: This study demonstrates that WM in large parts of the brain is susceptible to disease processes in RR and CIS MS

  11. Spin-transfer torque induced dynamics of magnetic vortices in nanopillars

    International Nuclear Information System (INIS)

    Sluka, Volker

    2011-01-01

    The subject of this work are lithographically defined cylindrical nanopillars containing a stack of two Iron disks separated by a nonmagnetic spacer. The dimensions of the ferromagnetic disks are chosen such that at low magnetic fields, the so-called magnetic vortex is stabilized. In zero field, the magnetization of these objects is basically parallel to the disk plane and circulates the disk center. In doing so, the build-up of large in-plane stray fields is avoided. At the center of this distribution however, exchange forces turn the magnetization out of the disk plane, resulting in the formation of what is referred to as the vortex core. Magnetic vortices have attracted much attention in recent years. This interest is in large parts due to the highly interesting dynamic properties of these structures. In this work the static and dynamic properties of magnetic vortices and their behavior under the influence of spin-transfer torque are investigated. This is achieved by measuring the static and time dependent magnetoresistance under the influence of external magnetic fields. The samples allow the formation of a large variety of states. First, the focus is set on configurations, where one disk is in a vortex state while the other one is homogeneously magnetized. It is shown that spin-transfer torque excites the vortex gyrotropic mode in this configuration. The dependence of the mode frequency on the magnetic field is analyzed. The measurements show that as the vortex center of gyration shifts through the disk under the action of the magnetic field, the effective potential in which it is moving undergoes a change in shape. This shape change is reflected in a V-shaped field dependence of the gyration frequency. Analytical calculations are performed to investigate the effect of the asymmetry of the spin-transfer torque efficiency function on the vortex dynamics. It is shown that by means of asymmetry, spin-transfer torque can transfer energy to a gyrating vortex even

  12. Quantitative magnetization transfer imaging of rodent glioma using selective inversion recovery.

    Science.gov (United States)

    Xu, Junzhong; Li, Ke; Zu, Zhongliang; Li, Xia; Gochberg, Daniel F; Gore, John C

    2014-03-01

    Magnetization transfer (MT) provides an indirect means to detect noninvasively variations in macromolecular contents in biological tissues, but, so far, there have been only a few quantitative MT (qMT) studies reported in cancer, all of which used off-resonance pulsed saturation methods. This article describes the first implementation of a different qMT approach, selective inversion recovery (SIR), for the characterization of tumor in vivo using a rodent glioma model. The SIR method is an on-resonance method capable of fitting qMT parameters and T1 relaxation time simultaneously without mapping B0 and B1 , which is very suitable for high-field qMT measurements because of the lower saturation absorption rate. The results show that the average pool size ratio (PSR, the macromolecular pool versus the free water pool) in rat 9 L glioma (5.7%) is significantly lower than that in normal rat gray matter (9.2%) and white matter (17.4%), which suggests that PSR is potentially a sensitive imaging biomarker for the assessment of brain tumor. Despite being less robust, the estimated MT exchange rates also show clear differences from normal tissues (19.7 Hz for tumors versus 14.8 and 10.2 Hz for gray and white mater, respectively). In addition, the influence of confounding effects, e.g. B1 inhomogeneity, on qMT parameter estimates is investigated with numerical simulations. These findings not only help to better understand the changes in the macromolecular contents of tumors, but are also important for the interpretation of other imaging contrasts, such as chemical exchange saturation transfer of tumors. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Optimization of selective inversion recovery magnetization transfer imaging for macromolecular content mapping in the human brain.

    Science.gov (United States)

    Dortch, Richard D; Bagnato, Francesca; Gochberg, Daniel F; Gore, John C; Smith, Seth A

    2018-03-24

    To optimize a selective inversion recovery (SIR) sequence for macromolecular content mapping in the human brain at 3.0T. SIR is a quantitative method for measuring magnetization transfer (qMT) that uses a low-power, on-resonance inversion pulse. This results in a biexponential recovery of free water signal that can be sampled at various inversion/predelay times (t I/ t D ) to estimate a subset of qMT parameters, including the macromolecular-to-free pool-size-ratio (PSR), the R 1 of free water (R 1f ), and the rate of MT exchange (k mf ). The adoption of SIR has been limited by long acquisition times (≈4 min/slice). Here, we use Cramér-Rao lower bound theory and data reduction strategies to select optimal t I /t D combinations to reduce imaging times. The schemes were experimentally validated in phantoms, and tested in healthy volunteers (N = 4) and a multiple sclerosis patient. Two optimal sampling schemes were determined: (i) a 5-point scheme (k mf estimated) and (ii) a 4-point scheme (k mf assumed). In phantoms, the 5/4-point schemes yielded parameter estimates with similar SNRs as our previous 16-point scheme, but with 4.1/6.1-fold shorter scan times. Pair-wise comparisons between schemes did not detect significant differences for any scheme/parameter. In humans, parameter values were consistent with published values, and similar levels of precision were obtained from all schemes. Furthermore, fixing k mf reduced the sensitivity of PSR to partial-volume averaging, yielding more consistent estimates throughout the brain. qMT parameters can be robustly estimated in ≤1 min/slice (without independent measures of ΔB 0 , B1+, and T 1 ) when optimized t I -t D combinations are selected. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Magnetization transfer contrast MR imaging of the knee at 0.3 T

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Onaya, Hiroaki; Niitsu, Mamoru; Anno, Izumi; Itai, Yuji; Nishimura, Hiroshi; Kajiyama, Koji; Masuda, Tomonori; Nakajima, Kotaro.

    1994-01-01

    It has been reported that magnetization transfer contrast (MTC) images were effective in evaluating the articular cartilage. However, only one in vivo study of the articular cartilage in the knee has been demonstrated at 1.5T. The purpose of this study was to evaluate the optimal off-resonance MTC pulse at 0.3T MR imager and assess its clinical usefulness. Five normal volunteers and eleven patients with suspected knee injuries were investigated using off-resonance sinc, gaussian, constant shaped irradiation pulses. All MTC images revealed higher contrast and contrast-to-noise (C/N) ratio between articular cartilage and external reference (saline) in the normal volunteers' knee than conventional gradient recalled echo images. MTC images with the gaussian or sinc shaped pulse were judged superior to those with constant wave pulse because the former images showed a fewer artifact with lower specific absorption rate than the latter images. The sinc MTC images were performed with the lowest SAR. The gaussian MTC images revealed better contrast and C/N between articular cartilage and joint fluid than the sinc MTC images in patients. 3D MTC images using Guassian pulse were also performed within a clinically tolerable imaging time (13 min 39 sec). Thus, MTC images in the knee at 0.3T using off-resonance pulse may be effective to assess knee injury due to better contrast between articular cartilage and joint fluid. (author)

  15. Pelvic interstitial brachytherapy - improving the therapeutic ratio with magnetic resonance imaging and optimization

    International Nuclear Information System (INIS)

    Swift, Patrick S.; Hricak, Hedvig; Forstner, Rosemary; Powell, C. Bethan; Purser, Phil; Weaver, Keith; Phillips, Theodore L.

    1996-01-01

    Introduction Interstitial brachytherapy in the pelvic region is often hampered by the radiation oncologist's inability to precisely differentiate tumor versus normal tissue during the planning and implantation procedures, often resulting in either excessive or incomplete coverage of tumor volume. The marked improvement in pelvic imaging seen with magnetic resonance, in conjunction with isodose optimization programs for remote-afterloading units, has created an opportunity to significantly improve the therapeutic ratio. Methods From 1992-1995, 23 interstitial perineal templates were performed in 22 patients with pelvic malignancies, using the pulsed low-dose-rate Selectron with dose optimization. MR imaging was performed immediately prior to the implant, with a MUPIT placed against the perineum and a vaginal obturator in place. These images were used for tumor volume measurements, determination of the number, depth and angle of needles required for the implant, and identification of position of normal tissues (rectum, small bowel, bladder) relative to the tumor. After implantation of stainless steel needles, orthogonal radiographs were obtained for isodose calculation, and planning carried out with isodose optimization. Patients were followed closely on a routine schedule, until time of last visit or until death. Every effort possible was made to assess local disease status at time of death. Results Sixteen patients with primary disease (14 cervix, 1 vulva, 1 vagina) and 6 with recurrent (2 with prior radiation) were implanted, all but 3 with curative intent. Nine patients with advanced cervix or vulvar cancer received concomitant chemotherapy (5FU + platinum or mitomycin-C) with the external beam therapy. At a median follow-up of 18.1 months for all cases, only three patients have failed locally for an actuarial local control of 85% at 1.5 years. Nine patients are alive and free of disease, 8 are alive with distant disease only (mean follow-up of 19.1 months), 2

  16. Scaling Projections on Spin-Transfer Torque Magnetic Tunnel Junctions

    Science.gov (United States)

    Das, Debasis; Tulapurkar, Ashwin; Muralidharan, Bhaskaran

    2018-02-01

    We investigate scaling of technologically relevant magnetic tunnel junction devices in the trilayer and pentalayer configurations by varying the cross-sectional area along the transverse direction using the non-equilibrium Green's function spin transport formalism. We study the geometry dependence by considering square and circular cross-sections. As the transverse dimension in each case reduces, we demonstrate that the transverse mode energy profile plays a major role in the resistance-area product. Both types of devices show constant tunnel magnetoresistance at larger cross-sectional areas but achieve ultra-high magnetoresistance at small cross-sectional areas, while maintaining low resistance-area products. We notice that although the critical switching voltage for switching the magnetization of the free layer nanomagnet in the trilayer case remains constant at larger areas, it needs more energy to switch at smaller areas. In the pentalayer case, we observe an oscillatory behavior at smaller areas as a result of double barrier tunneling. We also describe how switching characteristics of both kinds of devices are affected by the scaling.

  17. Influence of water–air ratio on the heat transfer and creep life of a high pressure gas turbine blade

    International Nuclear Information System (INIS)

    Eshati, S.; Abu, A.; Laskaridis, P.; Khan, F.

    2013-01-01

    An analytical model to investigate the influence of Water–Air Ratio (WAR) on turbine blade heat transfer and cooling processes (and thus the blade creep life) of industrial gas turbines is presented. The effects of WAR are emphasised for the modelling of the gas properties and the subsequent heat transfer process. The approach considers convective/film cooling and includes the influence of a thermal barrier coating. In addition, the approach is based on the thermodynamic outputs of a gas turbine performance simulation, heat transfer model, as well as a method that accounts for the changes in the properties of moist air as a function of WAR. For a given off-design point, the variation of WAR (0.0–0.10) was investigated using the heat transfer model. Results showed that with increasing WAR the blade inlet coolant temperature reduced along the blade span. The blade metal temperature at each section was reduced as WAR increased, which in turn increased the blade creep life. The increase in WAR increased the specific heat of the coolant and increased the heat transfer capacity of the coolant air flow. The model can be implemented by using the thermodynamic cycle of the engine, without knowing the turbine cooling details in the conceptual design stage. Also, this generic method assists the end user to understand the effect of operating conditions and design parameter on the creep life of a high pressure turbine blade. -- Highlights: • The influence of WAR on gas turbine blade heat transfer and creep life is examined. • Coolant specific heat capacity is the key property affected by changes in WAR. • Increase in WAR reduces the coolant and metal temperature along the blade span. • Creep life increases with increase in WAR even if ambient temperature is increased

  18. Analytical study of synchronization in spin-transfer-driven magnetization dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bonin, Roberto [Politecnico di Torino - sede di Verres, via Luigi Barone 8, I-11029 Verres (Italy); Bertotti, Giorgio; Bortolotti, Paolo [Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, I-10135 Torino (Italy); Serpico, Claudio [Dipartimento di Ingegneria Elettrica, Universita di Napoli ' Federico II' , via Claudio 21, I-80125 Napoli (Italy); D' Aquino, Massimiliano [Dipartimento per le Tecnologie, Universita di Napoli ' Parthenope' , via Medina 40, I-80133 Napoli (Italy); Mayergoyz, Isaak D, E-mail: p.bortolotti@inrim.i [Electrical and Computer Engineering Department and UMIACS, University of Maryland, College Park MD 20742 (United States)

    2010-01-01

    An analytical study of the synchronization effects in spin-transfer-driven nanomagnets subjected to either microwave magnetic fields or microwave electrical currents is discussed. Appropriate stability diagrams are constructed and the conditions under which the current-induced magnetization precession is synchronized by the microwave external excitation are derived and discussed. Analytical predictions are given for the existence of phase-locking effects in current-induced magnetization precessions and for the occurrence of hysteresis in phase-locking as a function of the spin-polarized current.

  19. Alignment Compensation for Bending Radius in TT40 and TI 8 Transfer Line Magnets

    CERN Document Server

    Weterings, W

    2003-01-01

    The BEATCH file for the TI 8 transfer lines specifies the position of the bending magnets assuming that the beam enters and exits at the centre of the vacuum pipe. In order to distribute the deflected beam evenly inside the vacuum tube, the alignment has to be compensated by moving the magnets half of the beam deflection away from the centre of the bending radius. In this note the saggitas of the various TT40 and TI 8 magnets are calculated and the alignment displacements tabulated for future reference.

  20. Alignment Compensation for Bending Radius in TI 2 Transfer Line Magnets

    CERN Document Server

    Weterings, W

    2004-01-01

    The optics file for the TI 2 transfer lines specifies the position of the bending magnets assuming that the beam enters and exists at the centre of the vacuum pipe. In order to disbribute the deflected beam evenly inside the vacuum tube, the alignment has to be compensated by moving the magnets half of the beam deflection away from the centre of the bending radius. In this note the saggitas of the various TI 2 magnets are calculated and the alignment displacements tabulated for future reference.

  1. Effects of magnetic fields on improving mass transfer in flue gas desulfurization using a fluidized bed

    Science.gov (United States)

    Zhang, Qi; Gui, Keting; Wang, Xiaobo

    2016-02-01

    The effects of magnetic fields on improving the mass transfer in flue gas desulfurization using a fluidized bed are investigated in the paper. In this research, the magnetically fluidized bed (MFB) is used as the reactor in which ferromagnetic particles are fluidized with simulated flue gas under the influence of an external magnetic field. Lime slurry is continuously sprayed into the reactor. As a consequence, the desulfurization reaction and the slurry drying process take place simultaneously in the MFB. In this paper, the effects of ferromagnetic particles and external magnetic fields on the desulphurization efficiency are studied and compared with that of quartz particles as the fluidized particles. Experimental results show that the ferromagnetic particles not only act as a platform for lime slurry to precipitate on like quartz particles, but also take part in the desulfurization reaction. The results also show that the specific surface area of ferromagnetic particles after reaction is enlarged as the magnetic intensity increases, and the external magnetic field promotes the oxidation of S(IV), improving the mass transfer between sulphur and its sorbent. Hence, the efficiency of desulphurization under the effects of external magnetic fields is higher than that in general fluidized beds.

  2. Natural convection and boiling heat transfer of a liquid metal in a magnetic field

    International Nuclear Information System (INIS)

    Seki, Masahiro; Kawamura, Hiroshi

    1983-02-01

    A liquid metal is often assumed as a coolant and a breeding material of a Tokamak fusion reactor. However, many problems on the thermo-hydraulics of a liquid metal in a magnetic field are still remained to be studied. In the present report, natural convection and boiling of a liquid metal in a strong magnetic field are studied to examine a fundamental feasibility of a fusion reactor cooled by a liquid metal. In the experimental study of the natural convection, the circulation of a liquid metal was found to be surpressed even by a magnetic field parallel to the gravity. A numerical study has confirmed the conclusion drawn by the experiment. In the study of boiling heat transfer, stable boiling of a liquid metal has been found also in a strong magnetic field. The burnout heat flux hardly affected by the magnetic field. These indicate a fundamental feasibility of the liquid-metal cooling for a Tokamak fusion reactor. (author)

  3. Anomalous Tunnel Magnetoresistance and Spin Transfer Torque in Magnetic Tunnel Junctions with Embedded Nanoparticles

    Science.gov (United States)

    Useinov, Arthur; Ye, Lin-Xiu; Useinov, Niazbeck; Wu, Te-Ho; Lai, Chih-Huang

    2015-01-01

    The tunnel magnetoresistance (TMR) in the magnetic tunnel junction (MTJ) with embedded nanoparticles (NPs) was calculated in range of the quantum-ballistic model. The simulation was performed for electron tunneling through the insulating layer with embedded magnetic and non-magnetic NPs within the approach of the double barrier subsystem connected in parallel to the single barrier one. This model can be applied for both MTJs with in-plane magnetization and perpendicular one. We also calculated the in-plane component of the spin transfer torque (STT) versus the applied voltage in MTJs with magnetic NPs and determined that its value can be much larger than in single barrier system (SBS) for the same tunneling thickness. The reported simulation reproduces experimental data of the TMR suppression and peak-like TMR anomalies at low voltages available in leterature. PMID:26681336

  4. Accuracy of signal-to-noise ratio measurement method for magnetic resonance images

    International Nuclear Information System (INIS)

    Ogura, Akio; Miyai, Akira; Maeda, Fumie; Fukutake, Hiroyuki; Kikumoto, Rikiya

    2003-01-01

    The signal-to-noise ratio (SNR) of a magnetic resonance image is a common measure of imager performance. However, evaluations for the calculation of the SNR use various methods. A problem with measuring SNR is caused by the distortion of noise statistics in commonly used magnitude images. In this study, measurement accuracy was compared among four methods of evaluating SNR according to the size and position of regions of interest (ROIs). The results indicated that the method that used the difference between two images showed the best agreement with the theoretical value. In the method that used a single image, the SNR calculated by using a small size of ROI showed better agreement with the theoretical value because of noise bias and image artifacts. However, in the method that used the difference between two images, a large size of ROI was better in reducing statistical errors. In the same way, the methods that used air noise and air signal were better when applied to a large ROI. In addition, the image subtraction process used to calculate pixel-by-pixel differences in images may reach zero on a minus pixel value when using an image processor with the MRI system and apparatuses associated with it. A revised equation is presented for this case. It is important to understand the characteristics of each method and to choose a suitable method carefully according to the purpose of the study. (author)

  5. Inkjet Printing of High Aspect Ratio Superparamagnetic SU-8 Microstructures with Preferential Magnetic Directions

    Directory of Open Access Journals (Sweden)

    Loïc Jacot-Descombes

    2014-08-01

    Full Text Available Structuring SU-8 based superparamagnetic polymer composite (SPMPC containing Fe3O4 nanoparticles by photolithography is limited in thickness due to light absorption by the nanoparticles. Hence, obtaining thicker structures requires alternative processing techniques. This paper presents a method based on inkjet printing and thermal curing for the fabrication of much thicker hemispherical microstructures of SPMPC. The microstructures are fabricated by inkjet printing the nanoparticle-doped SU-8 onto flat substrates functionalized to reduce the surface energy and thus the wetting. The thickness and the aspect ratio of the printed structures are further increased by printing the composite onto substrates with confinement pedestals. Fully crosslinked microstructures with a thickness up to 88.8 μm and edge angle of 112° ± 4° are obtained. Manipulation of the microstructures by an external field is enabled by creating lines of densely aggregated nanoparticles inside the composite. To this end, the printed microstructures are placed within an external magnetic field directly before crosslinking inducing the aggregation of dense Fe3O4 nanoparticle lines with in-plane and out-of-plane directions.

  6. Magnetic nanoparticles stimulation to enhance liquid-liquid two-phase mass transfer under static and rotating magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Azimi, Neda; Rahimi, Masoud, E-mail: masoudrahimi@yahoo.com

    2017-01-15

    Rotating magnetic field (RMF) was applied on a micromixer to break the laminar flow and induce chaotic flow to enhance mass transfer between two-immiscible organic and aqueous phases. The results of RMF were compared to those of static magnetic field (SMF). For this purpose, experiments were carried out in a T-micromixer at equal volumetric flow rates of organic and aqueous phases. Fe{sub 3}O{sub 4} nanoparticles were synthesized by co-precipitation technique and they were dissolved in organic phase. Results obtained from RMF and SMF were compared in terms of overall volumetric mass transfer coefficient (K{sub L}a) and extraction efficiency (E) at various Reynolds numbers. Generally, RMF showed higher effect in mass transfer characteristics enhancement compared with SMF. The influence of rotational speeds of magnets (ω) in RMF was investigated, and measurable enhancements of K{sub L}a and E were observed. In RMF, the effect of magnetic field induction (B) was investigated. The results reveal that at constant concentration of nanoparticles, by increasing of B, mass transfer characteristics will be enhanced. The effect of various nanoparticles concentrations (ϕ) within 0.002–0.01 (w/v) on K{sub L}a and E at maximum induction of RMF (B=76 mT) was evaluated. Maximum values of K{sub L}a (2.1±0.001) and E (0.884±0.001) were achieved for the layout of RMF (B=76 mT), ω=16 rad/s and MNPs concentration of 0.008–0.01 (w/v). - Highlights: • Magnetic nanoparticles used for mixing of two immiscible liquids in a micromixer. • Extraction efficiency of rotating magnetic field (RMF) is compared with static one. • In RMF, the effect of the angular speed on KLa and E enhancement is reported. • In RMF, at a selected magnet distance effect of nanoparticle concentration is reported.

  7. Novel LY Converter Topologies for High Gain Transfer Ratio - A New Breed of XY Family

    DEFF Research Database (Denmark)

    Bhaskar, M.S.; Padmanaban, S.; Kulkarni, R.

    2016-01-01

    gain and minimum internal resistance; such as a photovoltaic MLI system, high voltage applications and electrical drives. The conspicuous features of proposed LY converter topologies are i) Single power control switch ii) Single Input source iii) Inverting output voltage iv) Transformer-less converter...... topologies v) High inverting voltage gain with moderate duty ratio vi) Less number of power devices and components. The proposed topologies have minimum internal resistance and its effect on voltage gain of LY converter is also discussed in detail. The simulation results are presented and the result...

  8. Investigation of tritium transfer to plants via the OBT/HTO and OBT/TFWT ratios

    International Nuclear Information System (INIS)

    Boyer, C.; Guetat, P.; Vichot, L.; Losset, Y.; Boyer, C.; Fromm, M.; Mavon, C.; Boyer, C.; Tatin-Froux, F.; Badot, P.M.

    2009-01-01

    After having recalled some concepts used to distinguish the various forms of water present in plants, and the reactions in presence of tritium, the authors discuss the biochemical behaviour of tritium. Then, they briefly report a literature survey and, for different plants and crops, indicate the values of the OBT/HTO (organically bound tritium/tritiated water) and OBT/TFWT (organically bound tritium/tissue free water tritium) ratios. They also report experimental studies performed by exposures of lettuces at the vicinity of a nuclear installation

  9. On Electromagnetic Modulation of Flow Instabilities, Mixing and Heat Transfer in Conducting and Magnetized Fluids

    NARCIS (Netherlands)

    Kenjeres, S.

    2016-01-01

    In the present paper we give a concise review of some recent highlights of our research dealing with electromagnetic control of flow, mixing and heat transfer of electrically conductive or magnetized fluids. We apply a combination of state-of-art numerical (DNS and LES) and experimental (PIV and

  10. Modulation of the wall-heat transfer in turbulent thermomagnetic convection by magnetic field gradients

    NARCIS (Netherlands)

    Kenjeres, S.; Zinsmeester, R.; Pyrda, L.; Fornalik-Wajs, E.; Szmyd, J.

    2015-01-01

    We present combined experimental and numerical studies of the heat transfer of paramagnetic or diamagnetic fluid inside a differentially heated cubical enclosure subjected to the magnetic field gradients of different strength and orientation. In contrast to the previously reported studies in

  11. Analisa Compact Wireless Power Transfer (CWPT menggunakan Metode Magnetic Resonator Coupling

    Directory of Open Access Journals (Sweden)

    Bambang Sudibya

    2016-12-01

    Full Text Available Magnetic Resonator Coupling banyak dipergunakan untuk berbagai aplikasi Wireless Power Transfer (WPT. Pada penelitian ini berhasil dirancang WPT dengan tegangan sebesar 5 V. Jika Tx dan Rx diposisikan saling berhadapan, tegangan maksimum 4,7 volt pada jarak 1 cm. Sementara itu, jika Tx dan Rx diposisikan berdampingan, tegangan yang dihasilkan dari 3.5V.

  12. Magnetically Recoverable Supported Ruthenium Catalyst for Hydrogenation of Alkynes and Transfer Hydrogenation of Carbonyl Compounds

    Science.gov (United States)

    A ruthenium (Ru) catalyst supported on magnetic nanoparticles (NiFe2O4) has been successfully synthesized and used for hydrogenation of alkynes at room temperature as well as transfer hydrogenation of a number of carbonyl compounds under microwave irradiation conditions. The cata...

  13. Magnetic resonance imaging of flow and mass transfer in electrohydrodynamic liquid bridges

    NARCIS (Netherlands)

    Wexler, Adam D.; Drusová, Sandra; Fuchs, Elmar C.; Woisetschläger, Jakob; Reiter, Gert; Fuchsjäger, Michael; Reiter, Ursula

    2017-01-01

    Abstract: Here, we report on the feasibility and use of magnetic resonance imaging-based methods to the study of electrohydrodynamic (EHD) liquid bridges. High-speed tomographic recordings through the longitudinal axis of water bridges were used to characterize the mass transfer dynamics, mixing,

  14. Electric-field control of magnetism via strain transfer across ferromagnetic/ferroelectric interfaces.

    Science.gov (United States)

    Taniyama, Tomoyasu

    2015-12-23

    By taking advantage of the coupling between magnetism and ferroelectricity, ferromagnetic (FM)/ferroelectric (FE) multiferroic interfaces play a pivotal role in manipulating magnetism by electric fields. Integrating the multiferroic heterostructures into spintronic devices significantly reduces energy dissipation from Joule heating because only an electric field is required to switch the magnetic element. New concepts of storage and processing of information thus can be envisioned when the electric-field control of magnetism is a viable alternative to the traditional current based means of controlling magnetism. This article reviews some salient aspects of the electric-field effects on magnetism, providing a short overview of the mechanisms of magneto-electric (ME) coupling at the FM/FE interfaces. A particular emphasis is placed on the ME effect via interfacial magneto-elastic coupling arising from strain transfer from the FE to FM layer. Recent results that demonstrate the electric-field control of magnetic anisotropy, magnetic order, magnetic domain wall motion, and etc are described. Obstacles that need to be overcome are also discussed for making this a reality for future device applications.

  15. Electric-field control of magnetism via strain transfer across ferromagnetic/ferroelectric interfaces

    International Nuclear Information System (INIS)

    Taniyama, Tomoyasu

    2015-01-01

    By taking advantage of the coupling between magnetism and ferroelectricity, ferromagnetic (FM)/ferroelectric (FE) multiferroic interfaces play a pivotal role in manipulating magnetism by electric fields. Integrating the multiferroic heterostructures into spintronic devices significantly reduces energy dissipation from Joule heating because only an electric field is required to switch the magnetic element. New concepts of storage and processing of information thus can be envisioned when the electric-field control of magnetism is a viable alternative to the traditional current based means of controlling magnetism. This article reviews some salient aspects of the electric-field effects on magnetism, providing a short overview of the mechanisms of magneto-electric (ME) coupling at the FM/FE interfaces. A particular emphasis is placed on the ME effect via interfacial magneto-elastic coupling arising from strain transfer from the FE to FM layer. Recent results that demonstrate the electric-field control of magnetic anisotropy, magnetic order, magnetic domain wall motion, and etc are described. Obstacles that need to be overcome are also discussed for making this a reality for future device applications. (topical review)

  16. Spin-transfer phenomena in layered magnetic structures: Physical phenomena and materials aspects

    International Nuclear Information System (INIS)

    Gruenberg, P.; Buergler, D.E.; Dassow, H.; Rata, A.D.; Schneider, C.M.

    2007-01-01

    During the past 20 years, layered structures consisting of ferromagnetic layers and spacers of various material classes with a thickness of only a few nanometers have revealed a variety of exciting and potentially very useful phenomena not present in bulk material. Representing distinct manifestations of spin-transfer processes, these phenomena may be categorized into interlayer exchange coupling (IEC), giant magnetoresistance (GMR), tunneling magnetoresistance (TMR), and the more recently discovered spin-transfer torque effect leading to current-induced magnetization switching (CIMS) and current-driven magnetization dynamics. These phenomena clearly confer novel material properties on magnetic layered structures with respect to the (magneto-)transport and the magnetostatic as well as magnetodynamic behavior. Here, we will first concentrate on the less well understood aspects of IEC across insulating and semiconducting interlayers and relate the observations to TMR in the corresponding structures. In this context, we will also discuss more recent advances in TMR due to the use of electrodes made from Heusler alloys and the realization of coherent tunneling in epitaxial magnetic tunneling junctions. Finally, we will review our results on CIMS in epitaxial magnetic nanostructures showing that normal and inverse CIMS can occur simultaneously in a single nanopillar device. In all cases discussed, material issues play a major role in the detailed understanding of the spin-transfer effects, in particular in those systems that yield the largest effects and are thus of utmost interest for applications

  17. Heat transfer enhancement of Fe{sub 3}O{sub 4} ferrofluids in the presence of magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Fadaei, Farzad; Shahrokhi, Mohammad; Molaei Dehkordi, Asghar, E-mail: amolaeid@sharif.edu; Abbasi, Zeinab

    2017-05-01

    In this article, three-dimensional (3D) forced-convection heat transfer of magnetic nanofluids in a pipe subject to constant wall heat flux in the presence of single or double permanent magnet(s) or current-carrying wire has been investigated and compared. In this regard, laminar fluid flow and equilibrium magnetization for the ferrofluid were considered. In addition, variations of magnetic field in different media were taken into account and the assumption of having a linear relationship of magnetization with applied magnetic field intensity was also relaxed. Effects of magnetic field intensity, nanoparticle volume fraction, Reynolds number value, and the type of magnetic field source (i.e., a permanent magnet or current-carrying wire) on the forced-convection heat transfer of magnetic nanofluids were carefully investigated. It was found that by applying the magnetic field, the fluid mixing could be intensified that leads to an increase in the Nusselt number value along the pipe length. Moreover, the obtained simulation results indicate that applying the magnetic field induced by two permanent magnets with a magnetization of 3×10{sup 5} (A/m) (for each one), the fully developed Nusselt number value can be increased by 196%. - Highlights: • 3D forced-convection heat transfer of magnetic nanofluids is investigated. • Effects of single or double permanent magnet on the heat transfer are studied. • Influences of magnetic field induced by a current-carrying wire are studied. • Effects of magnetic field intensity and Reynolds number value are studied. • Variations of magnetic field in different media are taken into account.

  18. Regional patterns of grey matter atrophy and magnetisation transfer ratio abnormalities in multiple sclerosis clinical subgroups: a voxel-based analysis study.

    Science.gov (United States)

    Mallik, Shahrukh; Muhlert, Nils; Samson, Rebecca S; Sethi, Varun; Wheeler-Kingshott, Claudia A M; Miller, David H; Chard, Declan T

    2015-04-01

    In multiple sclerosis (MS), demyelination and neuro-axonal loss occur in the brain grey matter (GM). We used magnetic resonance imaging (MRI) measures of GM magnetisation transfer ratio (MTR) and volume to assess the regional localisation of reduced MTR (reflecting demyelination) and atrophy (reflecting neuro-axonal loss) in relapsing-remitting MS (RRMS), secondary progressive MS (SPMS) and primary progressive MS (PPMS). A total of 98 people with MS (51 RRMS, 28 SPMS, 19 PPMS) and 29 controls had T1-weighted volumetric and magnetisation transfer scans. SPM8 was used to undertake voxel-based analysis (VBA) of GM tissue volumes and MTR. MS subgroups were compared with controls, adjusting for age and gender. A voxel-by-voxel basis correlation analysis between MTR and volume within each subject group was performed, using biological parametric mapping. MTR reduction was more extensive than atrophy. RRMS and SPMS patients showed proportionately more atrophy in the deep GM. SPMS and PPMS patients showed proportionately greater cortical MTR reduction. RRMS patients demonstrated the most correlation of MTR reduction and atrophy in deep GM. In SPMS and PPMS patients, there was less extensive correlation. These results suggest that in the deep GM of RRMS patients, demyelination and neuro-axonal loss may be linked, while in SPMS and PPMS patients, neuro-axonal loss and demyelination may occur mostly independently. © The Author(s), 2014.

  19. Magnetic field concentration using ferromagnetic material to propel a wireless power transfer based micro-robot

    Directory of Open Access Journals (Sweden)

    Dongwook Kim

    2018-05-01

    Full Text Available In this paper, we propose a novel coil structure, using a ferromagnetic material which concentrates the magnetic field, as the propulsion system of a wireless power transfer (WPT based micro-robot. This structure uses an incident magnetic field to induce current during wireless power transfer, to generate a Lorentz force. To prevent net cancelation of the Lorentz force in the load coil, ferrite films were applied to one side of the coil segment. The demonstrated simplicity and effectiveness of the proposed micro-robot showed its suitability for applications. Simulation and experimental results confirmed a velocity of 1.02 mm/s with 6 mW power transfer capacity for the 3 mm sized micro-robot.

  20. Magnetic field concentration using ferromagnetic material to propel a wireless power transfer based micro-robot

    Science.gov (United States)

    Kim, Dongwook; Park, Bumjin; Park, Jaehyoung; Park, Hyun Ho; Ahn, Seungyoung

    2018-05-01

    In this paper, we propose a novel coil structure, using a ferromagnetic material which concentrates the magnetic field, as the propulsion system of a wireless power transfer (WPT) based micro-robot. This structure uses an incident magnetic field to induce current during wireless power transfer, to generate a Lorentz force. To prevent net cancelation of the Lorentz force in the load coil, ferrite films were applied to one side of the coil segment. The demonstrated simplicity and effectiveness of the proposed micro-robot showed its suitability for applications. Simulation and experimental results confirmed a velocity of 1.02 mm/s with 6 mW power transfer capacity for the 3 mm sized micro-robot.

  1. Layered Black Phosphorus: Strongly Anisotropic Magnetic, Electronic, and Electron-Transfer Properties.

    Science.gov (United States)

    Sofer, Zdeněk; Sedmidubský, David; Huber, Štěpán; Luxa, Jan; Bouša, Daniel; Boothroyd, Chris; Pumera, Martin

    2016-03-01

    Layered elemental materials, such as black phosphorus, exhibit unique properties originating from their highly anisotropic layered structure. The results presented herein demonstrate an anomalous anisotropy for the electrical, magnetic, and electrochemical properties of black phosphorus. It is shown that heterogeneous electron transfer from black phosphorus to outer- and inner-sphere molecular probes is highly anisotropic. The electron-transfer rates differ at the basal and edge planes. These unusual properties were interpreted by means of calculations, manifesting the metallic character of the edge planes as compared to the semiconducting properties of the basal plane. This indicates that black phosphorus belongs to a group of materials known as topological insulators. Consequently, these effects render the magnetic properties highly anisotropic, as both diamagnetic and paramagnetic behavior can be observed depending on the orientation in the magnetic field. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Magnetization transfer and spin lock MR imaging of patellar cartilage degeneration at 0.1 T

    International Nuclear Information System (INIS)

    Koskinen, S.K.; Ylae-Outinen, H.; Komu, M.E.S.; Aho, H.J.

    1997-01-01

    Purpose: To investigate magnetization transfer (MT) parameters and rotating frame relaxation time T1ρ in patellar cartilage at different levels of degeneration. Material and Methods: Thirty cadaveric patellae were examined at 0.1 T using the time-dependent saturation-transfer MT technique and the spin lock (SL) technique. In an SL experiment, nuclear spins are locked with a radiofrequency (RF) field, and the locked nuclear magnetization relaxes along the magnetic component of the locking RF field. The specimens were divided into three groups according to the level of cartilage degeneration. MT parameters and T1ρ were measured. Results: The MT effect was greater in degenerated cartilage than in normal cartilage. T1ρ was longer in advanced cartilage degeneration than in intermediate cartilage degeneration. Conculsion: The results suggest that more studies are needed to fully establish the value of SL imaging in cartilage degeneration. (orig.)

  3. Magnetization rotation or generation of incoherent spin waves? Suggestions for a spin-transfer effect experiment

    International Nuclear Information System (INIS)

    Bazaliy, Y. B.; Jones, B. A.

    2002-01-01

    ''Spin-transfer'' torque is created when electric current is passed through metallic ferromagnets and may have interesting applications in spintronics. So far it was experimentally studied in ''collinear'' geometries, where it is difficult to predict whether magnetization will coherently rotate or spin-waves will be generated. Here we propose an easy modification of existing experiment in which the spin-polarization of incoming current will no longer be collinear with magnetization and recalculate the switching behavior of the device. We expect that a better agreement with the magnetization rotation theory will be achieved. That can be an important step in reconciling alternative points of view on the effect of spin-transfer torque

  4. Heat transfer from aluminum to He II: application to superconductive magnetic energy storage

    International Nuclear Information System (INIS)

    Van Sciver, S.W.; Boom, R.W.

    1979-01-01

    Heat transfer problems associated with large scale Superconductive Magnetic Energy Storage (SMES) are unique due to the proposed size of a unit. The Wisconsin design consists of a cryogenically stable magnet cooled with He II at 1.8 K. The special properties of He II (T 2 at 1.91 K and a recovery at 0.7 W/cm 2 . The advantages of operating the magnet under subcooled conditions are exemplified by improved heat transfer. The maximum at 1.89 K and 1.3 atm pressure is 2.3 W/cm 2 with recovery enhanced to 1.9 W/cm 2 . A conservative maximum heat flux of 0.5 W/cm 2 with an associated temperature difference of 0.5 K has been chosen for design. Elements of the experimental study as well as the design will be discussed

  5. GEP/GMP ratio by polarization transfer in (rvec e)p → e(rvec p)

    International Nuclear Information System (INIS)

    Mark Jones; Konrad Aniol; Baker, F.; Berthot, J.; Pierre Bertin; William Bertozzi; Auguste Besson; Louis Bimbot; Werner Boeglin; Edward Brash; Brown, D.; John Calarco; Lawrence Cardman; Chang, C.; Jian-Ping Chen; Eugene Chudakov; Steve Churchwell; Evaristo Cisbani; Daniel Dale; Raffaele De Leo; Alexandre Deur; Brian Diederich; John Domingo; Martin Epstein; Lars Ewell; Kevin Fissum; Fleck, A.; Helene Fonvieille; Salvatore Frullani; Juncai Gao; Franco Garibaldi; Ashot Gasparian; Gerstner, G. M.; Shalev Gilad; Ronald Gilman; Oleksandr Glamazdin; Charles Glashausser; Javier Gomez; Viktor Gorbenko; Alphonza Green; Jens-Ole Hansen; Calvin Howell; Garth Huber; Mauro Iodice; Cornelis de Jager; Stephanie Jaminion; Xiaodong Jiang; Kahl, William E.; James Kelly; Mohammad Khayat; Laird Kramer; Gerfried Kumbartzki; Michael Kuss; Lakuriki, E.; Geraud Laveissiere; John LeRose; Meihua Liang; Richard Lindgren; Nilanga Liyanage; George Lolos; Macri, R.; Richard Madey; Sergey Malov; Demetrius Margaziotis; Pete Markowitz; Kathy McCormick; Justin McIntyre; Meer, Rob van der; Robert Michaels; Brian Milbrath; Jean Mougey; Sirish Nanda; Ed Offermann; Zisis Papandreou; Charles Perdrisat; Gerassimos Petratos; Nikolai Piskunov; Roman Pomatsalyuk; David Prout; Vina Punjabi; Gilles Quemener; Ronald Ransome; Brian Raue; Yves Roblin; Julie Roche; Gary Rutledge; Paul Rutt; Arunava Saha; Teijiro Saito; Adam Sarty; Smith, T. P.; Sorokin, P.; Steffen Strauch; Riad Suleiman; Kazunori Takahashi; Jeffrey Templon; Luminita Todor; Paul Ulmer; Guido Urciuoli; Pascal Vernin; Branislav Vlahovic; Voskanian, H.; Krishni Wijesooriya; Bogdan Wojtsekhowski; Rhett Woo; Feng Xiong; Dan Zainea; Zilu Zhou

    2000-01-01

    The ratio of the proton's elastic electromagnetic form factors, G(E p )/G(M p ) was obtained by measuring P i and P l , the transverse and the longitudinal recoil proton polarization, respectively. For elastic ep to ep, G(E p )/G(M p ) is proportional to P t /P l . Simultaneous measurement of P t and P l in a polarimeter provides good control of the systematic uncertainty. The results for the ratio G(E p )/G(M p ) show a systematic decrease as Q 2 increases from 0.5 to 3.5 GeV 2 , indicating for the first time a definite difference in the spatial distribution of charge and magnetization currents in the proton

  6. Magnetic field emission comparison at different quality factors with series-series compensation network for inductive power transfer to vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Inductive power transfer is non-contact transfer of energy by means of magnetic fields. A higher secondary side quality factor at fixed input current ensures a linear increase in power transfer across the air gap. But also at the same time magnetic emissions to the surroundings increase. First...... of all in this paper an analytic expression for comparing the magnetic emissions at different quality factors is introduced. It is shown with help of simulations on Comsol that emissions have a lower increase as compared to linear increase in the power transferred with the quality factor as suggested...

  7. Optimal Magnetic Field Shielding Method by Metallic Sheets in Wireless Power Transfer System

    Directory of Open Access Journals (Sweden)

    Feng Wen

    2016-09-01

    Full Text Available To meet the regulations established to limit human exposure to time-varying electromagnetic fields (EMFs such as the International Committee on Non-Ionizing Radiation Protection (ICNIRP guidelines, thin metallic sheets are often used to shield magnetic field leakage in high power applications of wireless power transfer (WPT systems based on magnetic field coupling. However, the metals in the vicinity of the WPT coils cause the decrease of self and mutual inductances and increase of effective series resistance; as such, the electric performance including transmission power and the efficiency of the system is affected. With the research objective of further investigating excellent shielding effectiveness associated with system performance, the utilization of the optimal magnetic field shielding method by metallic sheets in magnetic field coupling WPT is carried out in this paper. The circuit and 3D Finite Element Analysis (FEA models are combined to predict the magnetic field distribution and electrical performance. Simulation and experiment results show that the method is very effective by obtaining the largest possible coupling coefficient of the WPT coils within the allowable range and then reducing the value nearest to and no smaller than the critical coupling coefficient via geometric unbroken metallic sheets. The optimal magnetic field shielding method which considers the system efficiency, transmission power, transmission distance, and system size is also achieved using the analytic hierarchy process (AHP. The results can benefit WPT by helping to achieve efficient energy transfer and safe use in metal shielded equipment.

  8. A Ratio-Analysis Method to the Dynamics of Excited State Proton Transfer: Pyranine in Water and Micelles.

    Science.gov (United States)

    Sahu, Kalyanasis; Nandi, Nilanjana; Dolai, Suman; Bera, Avisek

    2018-06-05

    Emission spectrum of a fluorophore undergoing excited state proton transfer (ESPT) often exhibits two distinct bands each representing emissions from protonated and deprotonated forms. The relative contribution of the two bands, best represented by an emission intensity ratio (R) (intensity maximum of the protonated band / intensity maximum of the deprotonated band), is an important parameter which usually denotes feasibility or promptness of the ESPT process. However, the use of ratio is only limited to the interpretation of steady-state fluorescence spectra. Here, for the first time, we exploit the time-dependence of the ratio (R(t)), calculated from time-resolved emission spectra (TRES) at different times, to analyze ESPT dynamics. TRES at different times were fitted with a sum of two lognormal-functions representing each peaks and then, the peak intensity ratio, R(t) was calculated and further fitted with an analytical function. Recently, a time-resolved area-normalized emission spectra (TRANES)-based analysis was presented where the decay of protonated emission or the rise of deprotonated emission intensity conveniently accounts for the ESPT dynamics. We show that these two methods are equivalent but the new method provides more insights on the nature of the ESPT process.

  9. Measurement of soil carbon oxidation state and oxidative ratio by 13C nuclear magnetic resonance

    Science.gov (United States)

    Hockaday, W.C.; Masiello, C.A.; Randerson, J.T.; Smernik, R.J.; Baldock, J.A.; Chadwick, O.A.; Harden, J.W.

    2009-01-01

    The oxidative ratio (OR) of the net ecosystem carbon balance is the ratio of net O2 and CO2 fluxes resulting from photosynthesis, respiration, decomposition, and other lateral and vertical carbon flows. The OR of the terrestrial biosphere must be well characterized to accurately estimate the terrestrial CO2 sink using atmospheric measurements of changing O2 and CO2 levels. To estimate the OR of the terrestrial biosphere, measurements are needed of changes in the OR of aboveground and belowground carbon pools associated with decadal timescale disturbances (e.g., land use change and fire). The OR of aboveground pools can be measured using conventional approaches including elemental analysis. However, measuring the OR of soil carbon pools is technically challenging, and few soil OR data are available. In this paper we test three solid-state nuclear magnetic resonance (NMR) techniques for measuring soil OR, all based on measurements of the closely related parameter, organic carbon oxidation state (Cox). Two of the three techniques make use of a molecular mixing model which converts NMR spectra into concentrations of a standard suite of biological molecules of known C ox. The third technique assigns Cox values to each peak in the NMR spectrum. We assess error associated with each technique using pure chemical compounds and plant biomass standards whose Cox and OR values can be directly measured by elemental analyses. The most accurate technique, direct polarization solid-state 13C NMR with the molecular mixing model, agrees with elemental analyses to ??0.036 Cox units (??0.009 OR units). Using this technique, we show a large natural variability in soil Cox and OR values. Soil Cox values have a mean of -0.26 and a range from -0.45 to 0.30, corresponding to OR values of 1.08 ?? 0.06 and a range from 0.96 to 1.22. We also estimate the OR of the carbon flux from a boreal forest fire. Analysis of soils from nearby intact soil profiles imply that soil carbon losses associated

  10. Design and control strategy applying the novel highly effective magnetic flux coupling (HEMFC) scheme for a non-contact power transfer system

    International Nuclear Information System (INIS)

    Chen, W.-P.; Huang, W.-N.; Chen, P.-S.; Fan, T.-Y.; Chen, M.-P.; Teng, C.-C.

    2006-01-01

    In this paper, the novel design concept for highly effective magnetic flux coupling (HEMFC) schemes, based on enhancement of path guiding effect for leakage flux transmitting, is proposed for a non-contact power transfer system. Two implementation techniques are presented herein utilizing simple structure opinions of specific slant air gap as well as adding of metal bushing components. Both simulation and experimental results demonstrate that the improvement of magnetic coupling ratio and overall system efficiency are achieved by applying the two HEMFC schemes as the power transmitting devices

  11. Heat and momentum transfer for magnetoconvection in a vertical external magnetic field

    Science.gov (United States)

    Zürner, Till; Liu, Wenjun; Krasnov, Dmitry; Schumacher, Jörg

    2016-11-01

    The scaling theory of Grossmann and Lohse for the turbulent heat and momentum transfer is extended to the magnetoconvection case in the presence of a (strong) vertical magnetic field. The comparison with existing laboratory experiments and direct numerical simulations in the quasistatic limit allows to restrict the parameter space to very low Prandtl and magnetic Prandtl numbers and thus to reduce the number of unknown parameters in the model. Also included is the Chandrasekhar limit for which the outer magnetic induction field B is large enough such that convective motion is suppressed and heat is transported by diffusion. Our theory identifies four distinct regimes of magnetoconvection which are distinguished by the strength of the outer magnetic field and the level of turbulence in the flow, respectively. LIMTECH Research Alliance and Research Training Group GK 1567 on Lorentz Force Velocimetry, funded by the Deutsche Forschungsgemeinschaft.

  12. Optimal design of implants for magnetically mediated hyperthermia: A wireless power transfer approach

    Science.gov (United States)

    Lang, Hans-Dieter; Sarris, Costas D.

    2017-09-01

    In magnetically mediated hyperthermia (MMH), an externally applied alternating magnetic field interacts with a mediator (such as a magnetic nanoparticle or an implant) inside the body to heat up the tissue in its proximity. Producing heat via induced currents in this manner is strikingly similar to wireless power transfer (WPT) for implants, where power is transferred from a transmitter outside of the body to an implanted receiver, in most cases via magnetic fields as well. Leveraging this analogy, a systematic method to design MMH implants for optimal heating efficiency is introduced, akin to the design of WPT systems for optimal power transfer efficiency. This paper provides analytical formulas for the achievable heating efficiency bounds as well as the optimal operating frequency and the implant material. Multiphysics simulations validate the approach and further demonstrate that optimization with respect to maximum heating efficiency is accompanied by minimizing heat delivery to healthy tissue. This is a property that is highly desirable when considering MMH as a key component or complementary method of cancer treatment and other applications.

  13. Magnetization transfer imaging of periventricular white matter lesions in patients with multi-infarct dementia

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Imon, Yukari; Asano, Tetsuichi; Iwamoto, Toshihiko; Takasaki, Masaru

    1998-01-01

    Using magnetization transfer (MT) imaging, we studied the underlying pathological conditions of periventricular hyperintense (PVH) white matter changes seen on T2-weighted MR images of patients with multi-infarct dementia. Twenty-two patients with multiple lacunar infarcts and PVH lesions, including 11 with dementia (diagnosed as multi-infarct dementia) and 11 without dementia, and 10 control subjects (with multiple lacunes, but no PVH lesion) were studied using the MT technique. MT ratios (MTRs) were calculated for PVH lesions (normal-appearing frontal white matter in controls) and the genu of the corpus callosum. Signal intensities on T2-weighted images in PVH lesions of patients were significantly higher than those in normal-appearing white matter of controls, while there were no significant differences in signal intensity in the genu of the corpus callosum among the dementia, non-dementia and control groups. However, MTRs in patients with PVH lesions were significantly lower than those in controls, and MTRs in demented patients were significantly lower than those in non-demented patients. Moreover, MTRs in the genu of the corpus callosum of demented patients were significantly lower than in those in non-demented patients and controls. MTRs in PVH lesions and the genu of the corpus callosum significantly correlated with Hasegawa's dementia scale score. These results suggest that there is some difference in histopathologic changes of PVH lesions between demented and non-demented patients and that the pathological substrate in the corpus callosum may play a role in inducing cognitive decline. Studies with MT imaging may allow the characterization of different pathological conditions that cannot be visualized by conventional MRI. (author)

  14. Poynting vector analysis for wireless power transfer between magnetically coupled coils with different loads.

    Science.gov (United States)

    Guo, Yunsheng; Li, Jiansheng; Hou, Xiaojuan; Lv, Xiaolong; Liang, Hao; Zhou, Ji; Wu, Hongya

    2017-04-07

    Wireless power transfer is a nonradiative type of transmission that is performed in the near-field region. In this region, the electromagnetic fields that are produced by both the transmitting and receiving coils are evanescent fields, which should not transmit energy. This then raises the question of how the energy can be transferred. Here we describe a theoretical study of the two evanescent field distributions at different terminal loads. It is shown that the essential principle of wireless energy transfer is the superposition of the two evanescent fields, and the resulting superimposed field is mediated through the terminal load. If the terminal load is either capacitive or inductive, then the superimposed field cannot transfer the energy because its Poynting vector is zero; in contrast, if the load is resistive, energy can then be conveyed from the transmitting coil to the receiving coil. The simulation results for the magnetic field distributions and the time-domain current waveforms agree very well with the results of the theoretical analysis. This work thus provides a comprehensive understanding of the energy transfer mechanism involved in the magnetic resonant coupling system.

  15. Review of heat transfer problems associated with magnetically-confined fusion reactor concepts

    International Nuclear Information System (INIS)

    Hoffman, M.A.; Werner, R.W.; Carlson, G.A.; Cornish, D.N.

    1976-01-01

    Conceptual design studies of possible fusion reactor configurations have revealed a host of interesting and sometimes extremely difficult heat transfer problems. The general requirements imposed on the coolant system for heat removal of the thermonuclear power from the reactor are discussed. In particular, the constraints imposed by the fusion plasma, neutronics, structure and magnetic field environment are described with emphasis on those aspects which are unusual or unique to fusion reactors. Then the particular heat transfer characteristics of various possible coolants including lithium, flibe, boiling alkali metals, and helium are discussed in the context of these general fusion reactor requirements. Some specific areas where further experimental and/or theoretical work is necessary are listed for each coolant along with references to the pertinent research already accomplished. Specialized heat transfer problems of the plasma injection and removal systems are also described. Finally, the challenging heat transfer problems associated with the superconducting magnets are reviewed, and once again some of the key unsolved heat transfer problems are enumerated

  16. Unsteady Magnetized Flow and Heat Transfer of a Viscoelastic fluid over a Stretching Surface

    Science.gov (United States)

    Ghosh, Sushil Kumar

    2017-12-01

    This paper is to study the flow of heated ferro-fluid over a stretching sheet under the influence of magnetic field. The fluid considered in the present investigation is a mixture of blood as well as fluid-dispersed magnetic nano particles and under this context blood is found to be the appropriate choice of viscoelastic, Walter's B fluid. The objective of the present work is to study the effect of various parameters found in the mathematical analysis. Taking into account the blood has zero electrical conductivity, magnetization effect has been considered in the governing equation of the present study with the use of ferro-fluid dynamics principle. By introducing appropriate non-dimensional variables into the governing equations of unsteady two-dimensional flow of viscoelastic fluid with heat transfer are converted to a set of ordinary differential equations with appropriate boundary conditions. Newton's linearization technique has been employed for the solution of non-linear ordinary differential equations. Important results found in the present investigation are the substantial influence of ferro-magnetic parameter, Prandlt number and the parameter associated with the thermal conductivity on the flow and heat transfer. It is observed that the presence of magnetic dipole essentially reduces the flow velocity in the vertical direction and that helps to damage the cancer cells in the tumor region.

  17. Magnetization switching driven by spin-transfer-torque in high-TMR magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Aurelio, D.; Torres, L.; Finocchio, G.

    2009-01-01

    This paper presents a numerical study of magnetization switching driven by spin-polarized current in high-TMR magnetic tunnel junctions (TMR>100%). The current density distribution throughout the free-layer is computed dynamically, by modeling the ferromagnet/insulator/ferromagnet trilayer as a series of parallel resistances. The validity of the main hypothesis, which states that the current flows perpendicular to the sample plane, has been verified by numerically solving the Poisson equation. Our results show that the nonuniform current density distribution is a source of asymmetry to the switching process. Furthermore, we observe that the reversal mechanisms are characterized by well-defined localized pre-switching oscillation modes.

  18. Magnetization transfer contrast imaging detects early white matter changes in the APP/PS1 amyloidosis mouse model

    Directory of Open Access Journals (Sweden)

    Jelle Praet

    2016-01-01

    Full Text Available While no definitive cure for Alzheimer's disease exists yet, currently available treatments would benefit greatly from an earlier diagnosis. It has previously been shown that Magnetization transfer contrast (MTC imaging is able to detect amyloid β plaques in old APP/PS1 mice. In the current study we investigated if MTC is also able to visualize early amyloid β (Aβ induced pathological changes. In a cross-sectional study, a comparison was made between the MT ratio of wild type (WT and APP/PS1 mice at 2, 4, 6, 8 and 24 months of age. We observed an increased MT-ratio in the cortex of 24 month old APP/PS1 mice as compared to WT mice. However, when comparing the MT-ratio of the cortex of WT mice with the MT-ratio of the APP/PS1 mice at 2, 4, 6 or 8 months of age, no significant changes could be observed. In contrast to the cortex, we consistently observed a decreased MT-ratio in the splenium of 4, 6 and 8 month old APP/PS1 mice as compared to age-matched WT mice. Lastly, the decreased MT-ratio in the splenium of APP/PS1 mice correlated to the Aβ plaque deposition, astrogliosis and microgliosis. This MT-ratio decrease did however not correlate to the myelin content. Combined, our results suggest that MTC is able to visualize early Aβ-induced changes in the splenium but not the cortex of APP/PS1 mice.

  19. Effect of aspect ratio on natural convective heat transfer adjacent to a vertival isothermal cylinder immersed in pure water

    International Nuclear Information System (INIS)

    Riu, Kap Jong; Eum, Yong Kyoon; Park, Sung Soon

    1990-01-01

    A numerical analysis is performed about the effect of aspect ratio on heat transfer adjacent to a vertical-isothermal cylinder of 0 deg C in pure water. The numerical results for the effect of aspect ratio are presented for ambient water temperature from 1.0 deg C to 15.0 deg C. They include velocity profiles, temperature profiles and mean Nusselt number for the entire flow field. The mean Nusselt numbers of vertival-isothermal cylinder are compared with that of vertival-isothermal plate in increasing aspect ratio of cylinder. Furthermore, the mean Nusselt numbers of unsteady region in the range of 0.084< R<0.328 are obtained by curve-fitting. The natural convection caused by phase change was investigated by experiments when the vertical ice cylinder was immersed in the pure water of which the tempetature range is from 2.0 to 10.0 deg C. Each figure shows a time-exposure photograph of flow occuring at the respective ambient water temperature conditions. As the ambient water temperature is increased from 2.0 to 10.0 deg C, the regimes of upward steady state flows, steady state dual flows and downward steady state flows are observed. Also, the variations of shapes of melting ice cylinder are investigated.(Author)

  20. Falkner-Skan Flow of a Maxwell Fluid with Heat Transfer and Magnetic Field

    Directory of Open Access Journals (Sweden)

    M. Qasim

    2013-01-01

    Full Text Available This investigation deals with the Falkner-Skan flow of a Maxwell fluid in the presence of nonuniform applied magnetic fi…eld with heat transfer. Governing problems of flow and heat transfer are solved analytically by employing the homotopy analysis method (HAM. Effects of the involved parameters, namely, the Deborah number, Hartman number, and the Prandtl number, are examined carefully. A comparative study is made with the known numerical solution in a limiting sense and an excellent agreement is noted.

  1. A Critical Review of Wireless Power Transfer via Strongly Coupled Magnetic Resonances

    Directory of Open Access Journals (Sweden)

    Xuezhe Wei

    2014-07-01

    Full Text Available Strongly coupled magnetic resonance (SCMR, proposed by researchers at MIT in 2007, attracted the world’s attention by virtue of its mid-range, non-radiative and high-efficiency power transfer. In this paper, current developments and research progress in the SCMR area are presented. Advantages of SCMR are analyzed by comparing it with the other wireless power transfer (WPT technologies, and different analytic principles of SCMR are elaborated in depth and further compared. The hot research spots, including system architectures, frequency splitting phenomena, impedance matching and optimization designs are classified and elaborated. Finally, current research directions and development trends of SCMR are discussed.

  2. Self-consistent treatment of spin and magnetization dynamic effect in spin transfer switching

    International Nuclear Information System (INIS)

    Guo Jie; Tan, Seng Ghee; Jalil, Mansoor Bin Abdul; Koh, Dax Enshan; Han, Guchang; Meng, Hao

    2011-01-01

    The effect of itinerant spin moment (m) dynamic in spin transfer switching has been ignored in most previous theoretical studies of the magnetization (M) dynamics. Thus in this paper, we proposed a more refined micromagnetic model of spin transfer switching that takes into account in a self-consistent manner of the coupled m and M dynamics. The numerical results obtained from this model further shed insight on the switching profiles of m and M, both of which show particular sensitivity to parameters such as the anisotropy field, the spin torque field, and the initial deviation between m and M.

  3. Identification of compounds with binding affinity to proteins via magnetization transfer from bulk water

    International Nuclear Information System (INIS)

    Dalvit, Claudio; Pevarello, Paolo; Tato, Marco; Veronesi, Marina; Vulpetti, Anna; Sundstroem, Michael

    2000-01-01

    A powerful screening by NMR methodology (WaterLOGSY), based on transfer of magnetization from bulk water, for the identification of compounds that interact with target biomolecules (proteins, RNA and DNA fragments) is described. The method exploits efficiently the large reservoir of H 2 O magnetization. The high sensitivity of the technique reduces the amount of biomolecule and ligands needed for the screening, which constitutes an important requirement for high throughput screening by NMR of large libraries of compounds. Application of the method to a compound mixture against the cyclin-dependent kinase 2 (cdk2) protein is presented

  4. Materials and Physics Challenges for Spin Transfer Torque Magnetic Random Access Memories

    Energy Technology Data Exchange (ETDEWEB)

    Heinonen, O.

    2014-10-05

    Magnetic random access memories utilizing the spin transfer torque effect for writing information are a strong contender for non-volatile memories scalable to the 20 nm node, and perhaps beyond. I will here examine how these devices behave as the device size is scaled down from 70 nm size to 20 nm. As device sizes go below ~50 nm, the size becomes comparable to intrinsic magnetic length scales and the device behavior does not simply scale with size. This has implications for the device design and puts additional constraints on the materials in the device.

  5. Coherent population transfer in multilevel systems with magnetic sublevels. II. Algebraic analysis

    International Nuclear Information System (INIS)

    Martin, J.; Shore, B.W.; Bergmann, K.

    1995-01-01

    We extend previous theoretical work on coherent population transfer by stimulated Raman adiabatic passage for states involving nonzero angular momentum. The pump and Stokes fields are either copropagating or counterpropagating with the corresponding linearly polarized electric-field vectors lying in a common plane with the magnetic-field direction. Zeeman splitting lifts the magnetic sublevel degeneracy. We present an algebraic analysis of dressed-state properties to explain the behavior noted in numerical studies. In particular, we discuss conditions which are likely to lead to a failure of complete population transfer. The applied strategy, based on simple methods of linear algebra, will also be successful for other types of discrete multilevel systems, provided the rotating-wave and adiabatic approximation are valid

  6. Coherent population transfer in multilevel systems with magnetic sublevels. II. Algebraic analysis

    Science.gov (United States)

    Martin, J.; Shore, B. W.; Bergmann, K.

    1995-07-01

    We extend previous theoretical work on coherent population transfer by stimulated Raman adiabatic passage for states involving nonzero angular momentum. The pump and Stokes fields are either copropagating or counterpropagating with the corresponding linearly polarized electric-field vectors lying in a common plane with the magnetic-field direction. Zeeman splitting lifts the magnetic sublevel degeneracy. We present an algebraic analysis of dressed-state properties to explain the behavior noted in numerical studies. In particular, we discuss conditions which are likely to lead to a failure of complete population transfer. The applied strategy, based on simple methods of linear algebra, will also be successful for other types of discrete multilevel systems, provided the rotating-wave and adiabatic approximation are valid.

  7. Measurements of differential cross-section ratios for single-nucleon transfer reaction pairs near A=25

    Energy Technology Data Exchange (ETDEWEB)

    Howard, A J; Moise, T S [Trinity Coll., Hartford, CT (USA). Dept. of Physics; Champagne, A E [Princeton Univ., NJ (USA). Dept. of Physics; Magnus, P V; Smith, M S [Yale Univ., New Haven, CT (USA). Wright Nuclear Structure Lab.

    1991-06-10

    Differential cross sections for the (d,p), ({sup 3}He,d), ({alpha},t) and ({alpha},{sup 3}He) reactions involving seventy-one residual states in {sup 23}Na, {sup 25}Mg, {sup 25}Al, and {sup 27}Al have been measured at a forward angle with incident energies of 17.5, 20.2, and 34.8 MeV, respectively. The ratio of cross-section pairs involving formation of the same residual state is determined for forty-five cases where both the angular momentum transfer and single-particle spectroscopic strength have been previously established. These are compared to values calculated with conventional distorted-wave Born approximation analysis, and the utility of this technique for identifying some levels which are possible s- or p-wave resonances is demonstrated and discussed for states in the vicinity of proton thresholds. An application is made involving proton threshold states in {sup 27}Al. (orig.).

  8. Restrictions on the Ratio of Normal to Tangential Field Components in Magnetic Rubber Testing

    National Research Council Canada - National Science Library

    Burke, S. K; Ibrahim, M. E

    2007-01-01

    Magnetic Rubber Testing (MRT) is an extremely sensitive method for deteckng surface-breaking cracks in ferromagnetic materials, and is used extensively in critical inspections for D6ac steel components of the F-111 aircraft...

  9. Properties of the transfer matrices of deflecting magnet systems for free electron laser

    International Nuclear Information System (INIS)

    Takao, Masaru

    1993-01-01

    The oscillation of the free electron laser (FEL) requires the high current and low emittance electron beam. The beam transport system should be achromatic and isochronous to preserve the brightness and the emittance of the electron beam. In this paper we clarify the algebraic properties of the transfer matrices of the magnetic deflection system, which is a key component in the beam transport line. (author)

  10. Magnet power supply control of the NSLS VUV and x-ray storage rings transfer lines

    International Nuclear Information System (INIS)

    Klein, J.D.; Ramamoorthy, S.; Singh, O.; Smith, J.D.

    1985-01-01

    The transfer lines for NSLS VUV and x-ray storage rings have been split. New power supplies have been incorporated with existing ones. The existing microprocessor system has been upgraded in order to control the additional functions. This system expands the input/output port of the microprocessor to an addressable serial/parallel link to each magnet power supply. The implementation of this system will be discussed

  11. Passive shielding effect on space profile of magnetic field emissions for wireless power transfer to vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Batra, T., E-mail: tba@et.aau.dk; Schaltz, E. [Department of Energy Technology, Aalborg University, Aalborg 9220 (Denmark)

    2015-05-07

    Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has been investigated with the help of simulations on Comsol for the four possible geometries—no shielding, ferrite, aluminum, and full shielding. As the reflected impedance varies for the four geometries, the primary current is varied accordingly to maintain constant power transfer to the secondary side. Surrounding magnetic field plots in the vertical direction show that maxima's of the two coils for the no shielding geometry are centered at the respective coils and for the remaining three are displaced closer to each other. This closeness would lead to more effective addition of the two coil fields and an increase in the resultant field from space point of view. This closeness varies with distance in the horizontal direction and vertical gap between the coils and is explained in the paper. This paper provides a better understanding of effect of the passive shielding materials on the space nature of magnetic fields for wireless power transfer for vehicle applications.

  12. Passive shielding effect on space profile of magnetic field emissions for wireless power transfer to vehicles

    International Nuclear Information System (INIS)

    Batra, T.; Schaltz, E.

    2015-01-01

    Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has been investigated with the help of simulations on Comsol for the four possible geometries—no shielding, ferrite, aluminum, and full shielding. As the reflected impedance varies for the four geometries, the primary current is varied accordingly to maintain constant power transfer to the secondary side. Surrounding magnetic field plots in the vertical direction show that maxima's of the two coils for the no shielding geometry are centered at the respective coils and for the remaining three are displaced closer to each other. This closeness would lead to more effective addition of the two coil fields and an increase in the resultant field from space point of view. This closeness varies with distance in the horizontal direction and vertical gap between the coils and is explained in the paper. This paper provides a better understanding of effect of the passive shielding materials on the space nature of magnetic fields for wireless power transfer for vehicle applications

  13. Study of magnetic field to promote oxygen transfer and its application in zinc–air fuel cells

    International Nuclear Information System (INIS)

    Shi, Jicheng; Xu, Hongfeng; Lu, Lu; Sun, Xin

    2013-01-01

    Highlights: ► High magnetic strength reduces R ct and increases C d in oxygen reduction reaction. ► Oxygen diffusion and transfer coefficient become large in high magnetic strength. ► The magnetic ZAFC discharge performance is better than the nonmagnetic ZAFC. ► Increased NdFeB/C load density improves the magnetic ZAFC discharge performance. ► Excess NdFeB/C load density decreases the magnetic ZAFC discharge performance. -- Abstract: This study investigates the effects of magnetic field on oxygen transfer and the correlations of electrochemical parameters in different magnetic strengths. The discharge performance of zinc–air fuel cell (ZAFC) was tested under magnetic and nonmagnetic conditions using neodymium–iron–boron/carbon (NdFeB/C) magnetic particles in ZAFC cathode. The results showed that the oxygen diffusion coefficient (D Oi ) and transfer coefficient (α i ) increased by 102.14% and 52.38% when the magnetic strength increased from 0 mT to 5.0 mT, respectively. In addition, the electric double-layer capacitance (C d ) increased from 8.16 to 22.46 μF cm −2 , the charge-transfer resistance (R ct ) decreased from 9.43 Ω cm 2 to 6.02 Ω cm 2 , and the oxygen reduction reaction (ORR) current was improved. With the NdFeB/C load density of 2.4 mg cm −2 in ZAFC cathode, the discharge current of magnetic ZAFC increased by 13.86% compared with the nonmagnetic ZAFC at the 0.80 V discharge voltage. These results indicate that magnetic strength has a positive correlation with D Oi , α i , and the ORR current. Under magnetic attractions, the oxygen transfer process is easier at the Pt/C catalytic surface, and the discharge performance of magnetic ZAFC is superior to the nonmagnetic ZAFC. At lower NdFeB/C load density, increasing the NdFeB/C load density facilitates oxygen transfer and improves the discharge performance of ZAFC. However, the magnetic ZAFC discharge performance decreases at a higher NdFeB/C load density because of the blocked oxygen

  14. Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion source

    International Nuclear Information System (INIS)

    Walder, A.J.; Freedman, P.A.

    1992-01-01

    An inductively coupled plasma source was coupled to a magnetic sector mass analyser equipped with seven Faraday detectors. An electrostatic filter located between the plasma source and the magnetic sector was used to create a double focusing system. Isotopic ratio measurements of uranium and lead standards revealed levels of internal and external precision comparable to those obtained using thermal inonization mass spectrometry. An external precision of 0.014% was obtained from the 235 U: 238 U measurement of six samples of a National Bureau of Standards (NBS) Standard Reference Material (SRM) U-500, while an RSD of 0.022% was obtained from the 206 Pb: 204 Pb measurement of six samples of NBS SRM Pb-981. Measured isotopic ratios deviated from the NBS value by approximately 0.9% per atomic mass unit. This deviation approximates to a linear function of mass bias and can therefore be corrected for by the analysis of standards. The analysis of NBS SRM Sr-987 revealed superior levels of internal and external precision. The normalization of the 87 Sr: 86 Sr ratio to the 86 Sr: 88 Sr ratio reduced the RSD to approximately 0.008%. The measured ratio was within 0.01% of the NBS value and the day-to-day reproducibility was consistent within one standard deviation. (author)

  15. Microfluidic active mixers employing ultra-high aspect-ratio rare-earth magnetic nano-composite polymer artificial cilia

    International Nuclear Information System (INIS)

    Rahbar, Mona; Gray, Bonnie L; Shannon, Lesley

    2014-01-01

    We present a new micromixer based on highly magnetic, flexible, high aspect-ratio, artificial cilia that are fabricated as individual micromixer elements or in arrays for improved mixing performance. These new cilia enable high efficiency, fast mixing in a microchamber, and are controlled by small electromagnetic fields. The artificial cilia are fabricated using a new micromolding process for nano-composite polymers. Cilia fibers with aspect-ratios as high as 8:0.13 demonstrate the fabrication technique's capability in creating ultra-high aspect-ratio microstructures. Cilia, which are realized in polydimethylsiloxane doped with rare-earth magnetic powder, are magnetized to produce permanent magnetic structures with bidirectional deflection capabilities, making them highly suitable as mixers controlled by electromagnetic fields. Due to the high magnetization level of the polarized nano-composite polymer, we are able to use miniature electromagnets providing relatively small magnetic fields of 1.1 to 7 mT to actuate the cilia microstructures over a very wide motion range. Mixing performances of a single cilium, as well as different arrays of multiple cilia ranging from 2 to 8 per reaction chamber, are characterized and compared with passive diffusion mixing performance. The mixer cilia are actuated at different amplitudes and frequencies to optimize mixing performance. We demonstrate that more than 85% of the total volume of the reaction chamber is fully mixed after 3.5 min using a single cilium mixer at 7 mT compared with only 20% of the total volume mixed with passive diffusion. The time to achieve over 85% mixing is further reduced to 70 s using an array of eight cilia microstructures. The novel microfabrication technique and use of rare-earth permanently-magnetizable nano-composite polymers in mixer applications has not been reported elsewhere by other researchers. We further demonstrate improved mixing over other cilia micromixers as enabled by the high

  16. A Wireless Magnetic Resonance Energy Transfer System for Micro Implantable Medical Sensors

    Directory of Open Access Journals (Sweden)

    Tianyang Yang

    2012-07-01

    Full Text Available Based on the magnetic resonance coupling principle, in this paper a wireless energy transfer system is designed and implemented for the power supply of micro-implantable medical sensors. The entire system is composed of the in vitro part, including the energy transmitting circuit and resonant transmitter coils, and in vivo part, including the micro resonant receiver coils and signal shaping chip which includes the rectifier module and LDO voltage regulator module. Transmitter and receiver coils are wound by Litz wire, and the diameter of the receiver coils is just 1.9 cm. The energy transfer efficiency of the four-coil system is greatly improved compared to the conventional two-coil system. When the distance between the transmitter coils and the receiver coils is 1.5 cm, the transfer efficiency is 85% at the frequency of 742 kHz. The power transfer efficiency can be optimized by adding magnetic enhanced resonators. The receiving voltage signal is converted to a stable output voltage of 3.3 V and a current of 10 mA at the distance of 2 cm. In addition, the output current varies with changes in the distance. The whole implanted part is packaged with PDMS of excellent biocompatibility and the volume of it is about 1 cm3.

  17. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    International Nuclear Information System (INIS)

    Shit, G.C.; Majee, Sreeparna

    2015-01-01

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field

  18. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    Energy Technology Data Exchange (ETDEWEB)

    Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in; Majee, Sreeparna

    2015-08-15

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field.

  19. Analysis of thermally induced magnetization dynamics in spin-transfer nano-oscillators

    Energy Technology Data Exchange (ETDEWEB)

    D' Aquino, M., E-mail: daquino@uniparthenope.it [Department of Technology, University of Naples ' Parthenope' , 80143 Naples (Italy); Serpico, C. [Department of Engineering, University of Naples Federico II, 80125 Naples (Italy); Bertotti, G. [Istituto Nazionale di Ricerca Metrologica 10135 Torino (Italy); Bonin, R. [Politecnico di Torino - Sede di Verres, 11029 Verres (Aosta) (Italy); Mayergoyz, I.D. [ECE Department and UMIACS, University of Maryland, College Park, MD 20742 (United States)

    2012-05-01

    The thermally induced magnetization dynamics in the presence of spin-polarized currents injected into a spin-valve-like structure used as microwave spin-transfer nano-oscillator (STNO) is considered. Magnetization dynamics is described by the stochastic Landau-Lifshitz-Slonczewski (LLS) equation. First, it is shown that, in the presence of thermal fluctuations, the spectrum of the output signal of the STNO exhibits multiple peaks at low and high frequencies. This circumstance is associated with the occurrence of thermally induced transitions between stationary states and magnetization self-oscillations. Then, a theoretical approach based on the separation of time-scales is developed to obtain a stochastic dynamics only in the slow state variable, namely the energy. The stationary distribution of the energy and the aforementioned transition rates are analytically computed and compared with the results of direct integration of the LLS dynamics, showing very good agreement.

  20. On Electromagnetic Modulation of Flow Instabilities, Mixing and Heat Transfer in Conducting and Magnetized Fluids

    Science.gov (United States)

    Kenjeres, S.

    2016-09-01

    In the present paper we give a concise review of some recent highlights of our research dealing with electromagnetic control of flow, mixing and heat transfer of electrically conductive or magnetized fluids. We apply a combination of state-of-art numerical (DNS and LES) and experimental (PIV and LIF) techniques to provide fundamental insights into the complex phenomena of interactions between imposed (or induced) electromagnetic fields and underlying fluid flow. Our analysis covers an extensive range of working fluids, i.e. weakly- and highly-electrically-conductive, as well as magnetized fluids. These interactions are defined through the presence of different types of body forces acting per volume of fluid. A fully closed system of governing equations containing an extended set of the Navier-Stokes and a simplified set of the Maxwell equations is presented. The four characteristic examples are selected: the electromagnetic control of self-sustained jet oscillations, the electromagnetic enhancement of heat transfer in thermal convection, the wake interactions behind magnetic obstacles and finally, the thermo-magnetic convection in differentially heated cubical enclosure. The comparative assessment between experimental and numerical results is presented. It is concluded that generally good agreement between simulations and experiments is obtained for all cases considered, proving the concept of electromagnetic modulation, which can be used in numerous technological applications.

  1. Integrable perturbed magnetic fields in toroidal geometry: An exact analytical flux surface label for large aspect ratio

    Energy Technology Data Exchange (ETDEWEB)

    Kallinikos, N.; Isliker, H.; Vlahos, L.; Meletlidou, E. [Department of Physics, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2014-06-15

    An analytical description of magnetic islands is presented for the typical case of a single perturbation mode introduced to tokamak plasma equilibrium in the large aspect ratio approximation. Following the Hamiltonian structure directly in terms of toroidal coordinates, the well known integrability of this system is exploited, laying out a precise and practical way for determining the island topology features, as required in various applications, through an analytical and exact flux surface label.

  2. Integrable perturbed magnetic fields in toroidal geometry: An exact analytical flux surface label for large aspect ratio

    Science.gov (United States)

    Kallinikos, N.; Isliker, H.; Vlahos, L.; Meletlidou, E.

    2014-06-01

    An analytical description of magnetic islands is presented for the typical case of a single perturbation mode introduced to tokamak plasma equilibrium in the large aspect ratio approximation. Following the Hamiltonian structure directly in terms of toroidal coordinates, the well known integrability of this system is exploited, laying out a precise and practical way for determining the island topology features, as required in various applications, through an analytical and exact flux surface label.

  3. Integrable perturbed magnetic fields in toroidal geometry: An exact analytical flux surface label for large aspect ratio

    International Nuclear Information System (INIS)

    Kallinikos, N.; Isliker, H.; Vlahos, L.; Meletlidou, E.

    2014-01-01

    An analytical description of magnetic islands is presented for the typical case of a single perturbation mode introduced to tokamak plasma equilibrium in the large aspect ratio approximation. Following the Hamiltonian structure directly in terms of toroidal coordinates, the well known integrability of this system is exploited, laying out a precise and practical way for determining the island topology features, as required in various applications, through an analytical and exact flux surface label

  4. The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI

    Directory of Open Access Journals (Sweden)

    Masoomeh Fooladi

    2007-12-01

    Full Text Available Introduction: Multiple sclerosis (MS is a demyelinating disease of the central nervous system (CNS, affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathological heterogeneities that occur in MS lesions and brain tissue.Quantitative magnetization transfer imaging (qMTI is a relatively new MRI technique which can be used to examine the pathological processes of the brain parenchyma which occur in MS patients.This quantitative MRI technique can provide more complete information about the extent and nature of the brain tissue destruction in multiple sclerosis, which cannot be detected by conventional MRI. Material and Methods: In this study, twelve patients with relapsing-remitting MS and twelve healthy control subjects underwent conventional MR imaging including: T2-FSE, T1-SE and FLAIR sequences as well as quantitative magnetization transfer imaging. All the focal lesions were identified on T2-weighted images and were classified according to their signal hypointensity on T1-weighted scans. The white matter and MS lesions were segmented using a semi-automated system. MT ratio (MTR histogram analysis was performed for the brain white matter and the average MTR value was calculated for the classified MS lesions. Results: A significant reduction was found in MTR value of the normal appearing white matter (NAWM in patients with relapsing-remitting MS, suggesting that MS is a more diffuse disease, affecting the whole brain tissue. A wide range changes in MTR values can be observed in MS lesions. MTR reduction is correlated with the degree of lesion hypointensity on T1-weighted scans. The lower MTR values of lesions that appear progressively more hypointense on T1-weigted images reflect varying degrees of demyelination and

  5. Parameterizing radiative transfer to convert MAX-DOAS dSCDs into near-surface box-averaged mixing ratios

    Directory of Open Access Journals (Sweden)

    R. Sinreich

    2013-06-01

    Full Text Available We present a novel parameterization method to convert multi-axis differential optical absorption spectroscopy (MAX-DOAS differential slant column densities (dSCDs into near-surface box-averaged volume mixing ratios. The approach is applicable inside the planetary boundary layer under conditions with significant aerosol load, and builds on the increased sensitivity of MAX-DOAS near the instrument altitude. It parameterizes radiative transfer model calculations and significantly reduces the computational effort, while retrieving ~ 1 degree of freedom. The biggest benefit of this method is that the retrieval of an aerosol profile, which usually is necessary for deriving a trace gas concentration from MAX-DOAS dSCDs, is not needed. The method is applied to NO2 MAX-DOAS dSCDs recorded during the Mexico City Metropolitan Area 2006 (MCMA-2006 measurement campaign. The retrieved volume mixing ratios of two elevation angles (1° and 3° are compared to volume mixing ratios measured by two long-path (LP-DOAS instruments located at the same site. Measurements are found to agree well during times when vertical mixing is expected to be strong. However, inhomogeneities in the air mass above Mexico City can be detected by exploiting the different horizontal and vertical dimensions probed by the MAX-DOAS and LP-DOAS instruments. In particular, a vertical gradient in NO2 close to the ground can be observed in the afternoon, and is attributed to reduced mixing coupled with near-surface emission inside street canyons. The existence of a vertical gradient in the lower 250 m during parts of the day shows the general challenge of sampling the boundary layer in a representative way, and emphasizes the need of vertically resolved measurements.

  6. Electrochemical growth of Co nanowires in ultra-high aspect ratio InP membranes: FFT-impedance spectroscopy of the growth process and magnetic properties.

    Science.gov (United States)

    Gerngross, Mark-Daniel; Carstensen, Jürgen; Föll, Helmut

    2014-01-01

    The electrochemical growth of Co nanowires in ultra-high aspect ratio InP membranes has been investigated by fast Fourier transform-impedance spectroscopy (FFT-IS) in the frequency range from 75 Hz to 18.5 kHz. The impedance data could be fitted very well using an electric circuit equivalent model with a series resistance connected in series to a simple resistor-capacitor (RC) element and a Maxwell element. Based on the impedance data, the Co deposition in ultra-high aspect ratio InP membranes can be divided into two different Co deposition processes. The corresponding share of each process on the overall Co deposition can be determined directly from the transfer resistances of the two processes. The impedance data clearly show the beneficial impact of boric acid on the Co deposition and also indicate a diffusion limitation of boric acid in ultra-high aspect ratio InP membranes. The grown Co nanowires are polycrystalline with a very small grain size. They show a narrow hysteresis loop with a preferential orientation of the easy magnetization direction along the long nanowire axis due to the arising shape anisotropy of the Co nanowires.

  7. Flow patterns and heat transfer characteristics of flat plate pulsating heat pipes with various asymmetric and aspect ratios of the channels

    International Nuclear Information System (INIS)

    Jang, Dong Soo; Lee, Joo Seong; Ahn, Jae Hwan; Kim, Dongwoo; Kim, Yongchan

    2017-01-01

    Highlights: • Flat plate pulsating heat pipes with asymmetric and aspect ratios were tested. • Flow patterns were investigated according to channel geometry and flow condition. • Heat transfer characteristics were analyzed with various heat inputs. • Optimum asymmetric and aspect ratios were suggested for maximum thermal performance. - Abstract: The thermal performance of flat plate pulsating heat pipes (PHPs) in compact electronic devices can be improved by adopting asymmetric channels with increased pressure differences and an unbalanced driving force. The objective of this study is to investigate the heat transfer characteristics of flat plate PHPs with various asymmetric ratios and aspect ratios in the channels. The thermal performance and flow pattern of the flat plate PHPs were measured by varying the asymmetric ratio from 1.0 to 4.0, aspect ratio from 2.5 to 5.0, and heat input from 2 to 28 W. The effects of the asymmetric ratio and aspect ratio on the thermal resistance were analyzed with the measured evaporator temperature and flow patterns at various heat inputs. With heat inputs of 6 W and 12 W, the optimum asymmetric ratio and aspect ratio for the flat plate PHPs were determined to be 4.0 and 2.5, respectively. With the heat input of 18 W, the optimum asymmetric ratio and aspect ratio were determined to be 1.5 and 2.5, respectively.

  8. An optimized framework for quantitative magnetization transfer imaging of the cervical spinal cord in vivo.

    Science.gov (United States)

    Battiston, Marco; Grussu, Francesco; Ianus, Andrada; Schneider, Torben; Prados, Ferran; Fairney, James; Ourselin, Sebastien; Alexander, Daniel C; Cercignani, Mara; Gandini Wheeler-Kingshott, Claudia A M; Samson, Rebecca S

    2018-05-01

    To develop a framework to fully characterize quantitative magnetization transfer indices in the human cervical cord in vivo within a clinically feasible time. A dedicated spinal cord imaging protocol for quantitative magnetization transfer was developed using a reduced field-of-view approach with echo planar imaging (EPI) readout. Sequence parameters were optimized based in the Cramer-Rao-lower bound. Quantitative model parameters (i.e., bound pool fraction, free and bound pool transverse relaxation times [ T2F, T2B], and forward exchange rate [k FB ]) were estimated implementing a numerical model capable of dealing with the novelties of the sequence adopted. The framework was tested on five healthy subjects. Cramer-Rao-lower bound minimization produces optimal sampling schemes without requiring the establishment of a steady-state MT effect. The proposed framework allows quantitative voxel-wise estimation of model parameters at the resolution typically used for spinal cord imaging (i.e. 0.75 × 0.75 × 5 mm 3 ), with a protocol duration of ∼35 min. Quantitative magnetization transfer parametric maps agree with literature values. Whole-cord mean values are: bound pool fraction = 0.11(±0.01), T2F = 46.5(±1.6) ms, T2B = 11.0(±0.2) µs, and k FB  = 1.95(±0.06) Hz. Protocol optimization has a beneficial effect on reproducibility, especially for T2B and k FB . The framework developed enables robust characterization of spinal cord microstructure in vivo using qMT. Magn Reson Med 79:2576-2588, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc

  9. Electro-mechanical energy conversion system having a permanent magnet machine with stator, resonant transfer link and energy converter controls

    Science.gov (United States)

    Skeist, S. Merrill; Baker, Richard H.

    2006-01-10

    An electro-mechanical energy conversion system coupled between an energy source and an energy load comprising an energy converter device including a permanent magnet induction machine coupled between the energy source and the energy load to convert the energy from the energy source and to transfer the converted energy to the energy load and an energy transfer multiplexer to control the flow of power or energy through the permanent magnetic induction machine.

  10. Magnetic forces and localized resonances in electron transfer through quantum rings.

    Science.gov (United States)

    Poniedziałek, M R; Szafran, B

    2010-11-24

    We study the current flow through semiconductor quantum rings. In high magnetic fields the current is usually injected into the arm of the ring preferred by classical magnetic forces. However, for narrow magnetic field intervals that appear periodically on the magnetic field scale the current is injected into the other arm of the ring. We indicate that the appearance of the anomalous-non-classical-current circulation results from Fano interference involving localized resonant states. The identification of the Fano interference is based on the comparison of the solution of the scattering problem with the results of the stabilization method. The latter employs the bound-state type calculations and allows us to extract both the energy of metastable states localized within the ring and the width of resonances by analysis of the energy spectrum of a finite size system as a function of its length. The Fano resonances involving states of anomalous current circulation become extremely narrow on both the magnetic field and energy scales. This is consistent with the orientation of the Lorentz force that tends to keep the electron within the ring and thus increases the lifetime of the electron localization within the ring. Absence of periodic Fano resonances in electron transfer probability through a quantum ring containing an elastic scatterer is also explained.

  11. Zero-field spin transfer oscillators based on magnetic tunnel junction having perpendicular polarizer and planar free layer

    Directory of Open Access Journals (Sweden)

    Bin Fang

    2016-12-01

    Full Text Available We experimentally studied spin-transfer-torque induced magnetization oscillations in an asymmetric MgO-based magnetic tunnel junction device consisting of an in-plane magnetized free layer and an out-of-plane magnetized polarizer. A steady auto-oscillation was achieved at zero magnetic field and room temperature, with an oscillation frequency that was strongly dependent on bias currents, with a large frequency tunability of 1.39 GHz/mA. Our results suggest that this new structure has a high potential for new microwave device designs.

  12. Cardiothoracic ratio on chest radiograph in pediatric heart disease: How does it correlate with heart volumes at magnetic resonance imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Grotenhuis, Heynric B. [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); Zhou, Cheng; Isaac, Kathryn V. [The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Tomlinson, George [University of Toronto, Department of Medicine, Toronto General Hospital and Mt. Sinai Hospital, Toronto (Canada); Seed, Mike; Grosse-Wortmann, Lars; Yoo, Shi-Joon [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada)

    2015-10-15

    The cardiothoracic ratio by chest radiograph is widely used as a marker of cardiac size. The purpose of this study is to correlate cardiothoracic ratio and cardiac volumes as measured by cardiovascular magnetic resonance (MR) in common structural and myopathic heart disease with increased cardiac size due to volume overload or hypertrophy. A retrospective single center study was performed in all patients between 2007 and 2013 with repaired tetralogy of Fallot (TOF), aortic regurgitation, isolated left-to-right shunt and hypertrophic cardiomyopathy (HCM) who underwent cardiovascular MR and chest radiograph within 6 months of each other. Cardiothoracic ratios by chest radiograph (frontal and lateral) were compared to cardiac volumes (indexed for body surface area) by cardiovascular MR. One hundred twenty-seven patients (mean age: 11.2 ± 5.5 years) were included in this study (76 with TOF, 23 with isolated left-to-right shunt, 16 with aortic regurgitation and 12 with HCM). Frontal cardiothoracic ratio of all groups correlated with indexed right ventricular (RV) end-diastolic volume (EDVI) (r = 0.40, P < 0.01) and indexed total heart volume (THVI) (r = 0.27, P < 0.01). In TOF patients, frontal cardiothoracic ratio correlated with RVEDVI (r = 0.34, P < 0.01; coefficient of variation = 27.6%), indexed RV end-systolic volume (ESVI) (r = 0.44, P < 0.01; coefficient of variation = 33.3%) and THVI (r = 0.35, P < 0.01; coefficient of variation = 19.6%), although RV volumes and THVI showed widespread variation given the high coefficients of variation. In patients with aortic regurgitation, frontal cardiothoracic ratio correlated with left ventricular (LV) EDVI (r = 0.50, P = 0.047), but not with THVI and aortic regurgitant fraction, and widespread variation for LV EDVI (coefficient of variation = 19.2%), LV ESVI (coefficient of variation = 32.5%) and THVI (coefficient of variation = 13.6%) was also observed. Frontal cardiothoracic ratio was not correlated with cardiac volumes

  13. Enhancement in heat transfer of a ferrofluid in a differentially heated square cavity through the use of permanent magnets

    Science.gov (United States)

    Joubert, J. C.; Sharifpur, M.; Solomon, A. Brusly; Meyer, J. P.

    2017-12-01

    The natural convection heat transfer of a magnetic nanofluid in a differentially heated cavity is investigated with and without an applied external magnetic field. The effects of volume fraction, magnetic field configuration, and magnetic field strength are investigated. Spherical Fe2O3 nanoparticles with a diameter of 15-20 nm are used in the nanofluids. Volume fractions ranging between 0.05% and 0.3% are tested for the case with no magnetic field, while only a volume fraction of 0.1% was tested in an externally applied magnetic field. The experiments were conducted for a range of Rayleigh numbers in 1.7 × 108 < Ra < 4.2 × 108. The viscosity of the nanofluid was determined experimentally. An empirical correlation for the viscosity was determined, and the stability of various nanofluids was investigated. Using heat transfer data obtained from the cavity, the average heat transfer coefficient and average Nusselt number for the nanofluids are determined. It was found that a volume fraction of 0.1% showed a maximum increase of 5.63% to the Nu at the maximum Ra. For the magnetic field study, it was found that the best-performing magnetic field enhanced the heat transfer behaviour by an additional 2.81% in Nu at Ra = 3.8 × 108.

  14. Evaluation of the transfer of heat from the coil of the LHC dipole magnet to Helium II

    International Nuclear Information System (INIS)

    Richter, D.; Sevred, A.; Fleiter, J.; Baudouy, B.; Devred, A.

    2007-01-01

    During operation of the Large Hadron Collider at CERN, heat will be generated inside the coils of its superconducting magnets as a consequence of ramping of magnetic field, and of the interaction of lost beam particles with the magnet mass. Heat has to be transferred from the conductor into the He II coolant and removed from the magnet environment. During the LHC R and D stage, this transfer has been extensively studied on simulated coil segments at CEA/Saclay, and by analyzing dynamic behavior of short model magnets at CERN. Owing to the importance of efficient cooling for the design of future superconducting accelerator magnets, study of heat transfer has been restored at CERN and in frame of the Next European Dipole Collaboration. The article features two recently performed works: 1) Attempt to analyse archived high ramp rate quench data of 1-m-long LHC model dipole magnets of the 2. generation. 2) Development of a method for direct measurement of heat transfer on segments of production LHC dipole magnet coils. (authors)

  15. Pulse electromagnetic fields enhance extracellular electron transfer in magnetic bioelectrochemical systems.

    Science.gov (United States)

    Zhou, Huihui; Liu, Bingfeng; Wang, Qisong; Sun, Jianmin; Xie, Guojun; Ren, Nanqi; Ren, Zhiyong Jason; Xing, Defeng

    2017-01-01

    Microbial extracellular electron transfer (EET) is essential in driving the microbial interspecies interaction and redox reactions in bioelectrochemical systems (BESs). Magnetite (Fe 3 O 4 ) and magnetic fields (MFs) were recently reported to promote microbial EET, but the mechanisms of MFs stimulation of EET and current generation in BESs are not known. This study investigates the behavior of current generation and EET in a state-of-the-art pulse electromagnetic field (PEMF)-assisted magnetic BES (PEMF-MBES), which was equipped with magnetic carbon particle (Fe 3 O 4 @N-mC)-coated electrodes. Illumina Miseq sequencing of 16S rRNA gene amplicons was also conducted to reveal the changes of microbial communities and interactions on the anode in response to magnetic field. PEMF had significant influences on current generation. When reactors were operated in microbial fuel cell (MFC) mode with pulse electromagnetic field (PEMF-MMFCs), power densities increased by 25.3-36.0% compared with no PEMF control MFCs (PEMF-OFF-MMFCs). More interestingly, when PEMF was removed, the power density dropped by 25.7%, while when PEMF was reintroduced, the value was restored to the previous level. Illumina sequencing of 16S rRNA gene amplicon and principal component analysis (PCA) based on operational taxonomic units (OTUs) indicate that PEMFs led to the shifts in microbial community and changes in species evenness that decreased biofilm microbial diversity. Geobacter spp. were found dominant in all anode biofilms, but the relative abundance in PEMF-MMFCs (86.1-90.0%) was higher than in PEMF-OFF-MMFCs (82.5-82.7%), indicating that the magnetic field enriched Geobacter on the anode. The current generation of Geobacter -inoculated microbial electrolysis cells (MECs) presented the same change regularity, the accordingly increase or decrease corresponding with switch of PEMF, which confirmed the reversible stimulation of PEMFs on microbial electron transfer. The pulse electromagnetic

  16. Imaging in Vivo Extracellular pH with a Single Paramagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent

    Directory of Open Access Journals (Sweden)

    Guanshu Liu

    2012-01-01

    Full Text Available The measurement of extracellular pH (pHe has potential utility for cancer diagnoses and for assessing the therapeutic effects of pH-dependent therapies. A single magnetic resonance imaging (MRI contrast agent that is detected through paramagnetic chemical exchange saturation transfer (PARACEST was designed to measure tumor pHe throughout the range of physiologic pH and with magnetic resonance saturation powers that are not harmful to a mouse model of cancer. The chemical characterization and modeling of the contrast agent Yb3+-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid, 10-o-aminoanilide (Yb-DO3A-oAA suggested that the aryl amine of the agent forms an intramolecular hydrogen bond with a proximal carboxylate ligand, which was essential for generating a practical chemical exchange saturation transfer (CEST effect from an amine. A ratio of CEST effects from the aryl amine and amide was linearly correlated with pH throughout the physiologic pH range. The pH calibration was used to produce a parametric pH map of a subcutaneous flank tumor on a mouse model of MCF-7 mammary carcinoma. Although refinements in the in vivo CEST MRI methodology may improve the accuracy of pHe measurements, this study demonstrated that the PARACEST contrast agent can be used to generate parametric pH maps of in vivo tumors with saturation power levels that are not harmful to a mouse model of cancer.

  17. One-Dimensional-Ratio Measures of Atrophy Progression in Multiple Sclerosis as Evaluated by Longitudinal Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Martola, J.; Wiberg Kristoffersen, M.; Aspelin, P.; Stawiarz, L.; Fredrikson, S.; Hillert, J.; Bergstroem, J.; Flodmark, O.

    2009-01-01

    Background: For decades, normalized one-dimensional (1D) measures have been used in the evaluation of brain atrophy. In multiple sclerosis (MS), the use of normalized linear measures over longitudinal follow-up remains insufficiently documented. Purpose: To evaluate the association between different regional atrophy measures and disability in MS patients over four decades in a longitudinal cross-sectional study. Material and Methods: 37 consecutively selected MS patients were included. At baseline, patients had a range of disease duration (1-33 years) and age (24-65 years). Each patient was followed by magnetic resonance imaging (MRI) for a mean of 9.25 years (range 7.3-10 years). Four 1D measures were applied at three time points on axial 5-mm T1-weighted images. Three clinical MS subgroups were represented: relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), and primary progressive MS (PPMS). Results: There were significant changes in all 1D ratios during follow-up. The Evans ratio (ER) and the bifrontal ratio (BFR) were associated with the development of disability. Changes of ER and BFR reflected more aggressive disease progression, as expressed by MS severity score (MSSS). Conclusion: All four normalized ratios showed uniform atrophy progression, suggesting a consistent rate of atrophy over long-term disease duration independent of MS course. Disability status correlated with 1D measures, suggesting that serial evaluation of Evans and bifrontal ratios might contribute to the radiological evaluation of MS patients

  18. A Computational Study on the Magnetic Resonance Coupling Technique for Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Zakaria N.A.

    2017-01-01

    Full Text Available Non-radiative wireless power transfer (WPT system using magnetic resonance coupling (MRC technique has recently been a topic of discussion among researchers. This technique discussed more scenarios in mid-range field of wireless power transmission reflected to the distance and efficiency. The WPT system efficiency varies when the coupling distance between two coils involved changes. This could lead to a decisive issue of high efficient power transfer. This paper presents case studies on the relationship of operating range with the efficiency of the MRC technique. Demonstrative WPT system operates at two different frequencies are projected in order to verify performance. The resonance frequencies used are less than 100MHz within range of 10cm to 20cm.

  19. Charge transfer of He2+ with H in a strong magnetic field

    International Nuclear Information System (INIS)

    Liu Chun-Lei; Zou Shi-Yang; He Bin; Wang Jian-Guo

    2015-01-01

    By solving a time-dependent Schrödinger equation (TDSE), we studied the electron capture process in the He 2+ +H collision system under a strong magnetic field in a wide projectile energy range. The strong enhancement of the total charge transfer cross section is observed for the projectile energy below 2.0 keV/u. With the projectile energy increasing, the cross sections will reduce a little and then increase again, compared with those in the field-free case. The cross sections to the states with different magnetic quantum numbers are presented and analyzed where the influence due to Zeeman splitting is obviously found, especially in the low projectile energy region. The comparison with other models is made and the tendency of the cross section varying with the projectile energy is found closer to that from other close coupling models. (paper)

  20. Spin transfer driven resonant expulsion of a magnetic vortex core for efficient rf detector

    Directory of Open Access Journals (Sweden)

    S. Menshawy

    2017-05-01

    Full Text Available Spin transfer magnetization dynamics have led to considerable advances in Spintronics, including opportunities for new nanoscale radiofrequency devices. Among the new functionalities is the radiofrequency (rf detection using the spin diode rectification effect in spin torque nano-oscillators (STNOs. In this study, we focus on a new phenomenon, the resonant expulsion of a magnetic vortex in STNOs. This effect is observed when the excitation vortex radius, due to spin torques associated to rf currents, becomes larger than the actual radius of the STNO. This vortex expulsion is leading to a sharp variation of the voltage at the resonant frequency. Here we show that the detected frequency can be tuned by different parameters; furthermore, a simultaneous detection of different rf signals can be achieved by real time measurements with several STNOs having different diameters. This result constitutes a first proof-of-principle towards the development of a new kind of nanoscale rf threshold detector.

  1. A novel macro-model for spin-transfer-torque based magnetic-tunnel-junction elements

    Science.gov (United States)

    Lee, Seungyeon; Lee, Hyunjoo; Kim, Sojeong; Lee, Seungjun; Shin, Hyungsoon

    2010-04-01

    Spin-transfer-torque (STT) switching in magnetic-tunnel-junction (MTJ) has important merits over the conventional field induced magnetic switching (FIMS) MRAM in avoiding half-select problem, and improving scalability and selectivity. Design of MRAM circuitry using STT-based MTJ elements requires an accurate circuit model which exactly emulates the characteristics of an MTJ in a circuit simulator such as HSPICE. This work presents a novel macro-model that fully emulates the important characteristics of STT-based MTJ. The macro-model is realized as a three terminal sub-circuit that reproduces asymmetric resistance versus current (R-I) characteristics and temperature dependence of R-I hysteresis of STT-based MTJ element.

  2. Optimal selection of annulus radius ratio to enhance heat transfer with minimum entropy generation in developing laminar forced convection of water-Al2O3 nanofluid flow

    Institute of Scientific and Technical Information of China (English)

    Siavashi Majid; Jamali Mohammad

    2017-01-01

    Heat transfer and entropy generation of developing laminar forced convection flow of water-Al2O3 nanofluid in a concentric annulus with constant heat flux on the walls is investigated numerically. In order to determine entropy generation of fully developed flow, two approaches are employed and it is shown that only one of these methods can provide appropriate results for flow inside annuli. The effects of concentration of nanoparticles, Reynolds number and thermal boundaries on heat transfer enhancement and entropy generation of developing laminar flow inside annuli with different radius ratios and same cross sectional areas are studied. The results show that radius ratio is a very important decision parameter of an annular heat exchanger such that in each Re, there is an optimum radius ratio to maximize Nu and minimize entropy generation. Moreover, the effect of nanoparticles concentration on heat transfer enhancement and minimizing entropy generation is stronger at higher Reynolds.

  3. Radiative transfer in a strongly magnetized plasma. I. Effects of Anisotropy

    International Nuclear Information System (INIS)

    Nagel, W.

    1981-01-01

    We present results of radiative transfer calculations for radiating slabs and columns of strongly magnetized plasma. The angular dependence of the escaping radiation was found numerically by Feautrier's method, using the differential scattering cross sections derived by Ventura. We also give an approximate analytical expression for the anisotropy of the outgoing radiation, based on a system of two coupled diffusion equations for ordinary and extraordinary photons. Giving the polarization dependence of the beaming pattern of radiating slabs as well as columns, we generalize previous results of Basko and Kanno. Some implications for models of the pulsating X-ray source Her X-1 are discussed

  4. Effect of collagen on magnetization transfer contrast assessed in cultured cartilage

    International Nuclear Information System (INIS)

    Aoki, Jun; Seo, Gwy-Suk; Karakida, Osamu; Ueda, Hitoshi; Sone, Shusuke; Hiraki, Yuji; Shukunami, Chisa; Moriya, Hiroto.

    1996-01-01

    We investigated the effect of collagen on magnetization transfer contrast (MTC) in cultured cartilage. In our culture system, only collagen synthesis was increased by the addition of vitamin C, while proteoglycan synthesis and the number of chondrocytes were unaffected. The MTC effect was assessed by using an off-resonance RF pulse (0.3 KHz off-resonance, sinc wave of 18 msec, maximum amplitude 4.61 x 10 -4 T) on a GRASS sequence. The cartilage cultured with vitamin C showed a higher MTC effect than that cultured without vitamin C. The major role of collagen on MTC was confirmed in living cartilage tissue. (author)

  5. Design of Novel FBG-Based Sensor of Differential Pressure with Magnetic Transfer

    Directory of Open Access Journals (Sweden)

    Guohui Lyu

    2017-02-01

    Full Text Available In this paper, a differential pressure sensor with magnetic transfer is proposed, in which the non-electric measurement based on the fiber Bragg grating (FBG with the position limiting mechanism is implemented without the direct contact of the sensing unit with the measuring fluid. The test shows that the designed sensor is effective for measuring differential pressure in the range of 0~10 kPa with a sensitivity of 0.0112 nm/kPa, which can be used in environments with high temperature, strong corrosion and high overload measurements.

  6. Design of Novel FBG-Based Sensor of Differential Pressure with Magnetic Transfer.

    Science.gov (United States)

    Lyu, Guohui; Che, Guohang; Li, Junqing; Jiang, Xu; Wang, Keda; Han, Yueqiang; Gao, Laixu

    2017-02-15

    In this paper, a differential pressure sensor with magnetic transfer is proposed, in which the non-electric measurement based on the fiber Bragg grating (FBG) with the position limiting mechanism is implemented without the direct contact of the sensing unit with the measuring fluid. The test shows that the designed sensor is effective for measuring differential pressure in the range of 0~10 kPa with a sensitivity of 0.0112 nm/kPa, which can be used in environments with high temperature, strong corrosion and high overload measurements.

  7. Transient heat transfer analysis of superconducting magnetic levitating flywheel rotor operating in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Mochida, A.; Kudo, K.; Higasa, H.

    1999-07-01

    In the present study, transient temperature rise is analyzed in a flywheel type power storage system operated in vacuum environment. The flywheel rotor is levitated by high-temperature-superconducting magnetic bearing to reduce the bearing loss. Though the superconductor is cooled by liquid nitrogen, the temperature of the whole system rises due to Joule heating in the coils of the bearings and the motor during the operation. If the temperature should reach the critical temperature of the permanent magnet used for the magnetic bearings after long time operation, the magnetic bearings lose their effect. The heat generated in the levitated rotor diffuses within it by heat conduction and finally emitted to its surrounding solid materials by thermal radiation from the rotor surfaces across vacuum layer. Numerical simulation is carried out calculating the transient radiative-conductive heat transfer and time-dependent profiles of temperature within the rotor are obtained. The results are compared with the experimentally obtained temperatures by measured a test model of 1kWh power storage and the measured profiles of the temperature rise of the rotor fit very well with the calculated ones. Using this simulation tool, the effects of the surface emissivity of the materials of the rotor and the stator, the temperature of the surrounding casings and the thermal conductivity of the materials on the temperature profiles in the system are estimated.

  8. Comptonization in Ultra-Strong Magnetic Fields: Numerical Solution to the Radiative Transfer Problem

    Science.gov (United States)

    Ceccobello, C.; Farinelli, R.; Titarchuk, L.

    2014-01-01

    We consider the radiative transfer problem in a plane-parallel slab of thermal electrons in the presence of an ultra-strong magnetic field (B approximately greater than B(sub c) approx. = 4.4 x 10(exp 13) G). Under these conditions, the magnetic field behaves like a birefringent medium for the propagating photons, and the electromagnetic radiation is split into two polarization modes, ordinary and extraordinary, that have different cross-sections. When the optical depth of the slab is large, the ordinary-mode photons are strongly Comptonized and the photon field is dominated by an isotropic component. Aims. The radiative transfer problem in strong magnetic fields presents many mathematical issues and analytical or numerical solutions can be obtained only under some given approximations. We investigate this problem both from the analytical and numerical point of view, provide a test of the previous analytical estimates, and extend these results with numerical techniques. Methods. We consider here the case of low temperature black-body photons propagating in a sub-relativistic temperature plasma, which allows us to deal with a semi-Fokker-Planck approximation of the radiative transfer equation. The problem can then be treated with the variable separation method, and we use a numerical technique to find solutions to the eigenvalue problem in the case of a singular kernel of the space operator. The singularity of the space kernel is the result of the strong angular dependence of the electron cross-section in the presence of a strong magnetic field. Results. We provide the numerical solution obtained for eigenvalues and eigenfunctions of the space operator, and the emerging Comptonization spectrum of the ordinary-mode photons for any eigenvalue of the space equation and for energies significantly lesser than the cyclotron energy, which is on the order of MeV for the intensity of the magnetic field here considered. Conclusions. We derived the specific intensity of the

  9. Alteration of the ground state by external magnetic fields. [External field, coupling constant ratio, static tree level approximation

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, B J; Shepard, H K [New Hampshire Univ., Durham (USA). Dept. of Physics

    1976-03-22

    By fully exploiting the mathematical and physical analogy to the Ginzburg-Landau theory of superconductivity, a complete discussion of the ground state behavior of the four-dimensional Abelian Higgs model in the static tree level approximation is presented. It is shown that a sufficiently strong external magnetic field can alter the ground state of the theory by restoring a spontaneously broken symmetry, or by creating a qualitatively different 'vortex' state. The energetically favored ground state is explicitly determined as a function of the external field and the ratio between coupling constants of the theory.

  10. Influence of writing and reading intertrack interferences in terms of bit aspect ratio in shingled magnetic recording

    Science.gov (United States)

    Nobuhara, Hirofumi; Okamoto, Yoshihiro; Yamashita, Masato; Nakamura, Yasuaki; Osawa, Hisashi; Muraoka, Hiroaki

    2014-05-01

    In this paper, we investigate the influence of the writing and reading intertrack interferences (ITIs) in terms of bit aspect ratio (BAR) in shingled magnetic recording by computer simulation using a read/write model which consists of a writing process based on Stoner-Wohlfarth switching asteroid by a one-side shielded isosceles triangular write head and a reading process by an around shielded read head for a discrete Voronoi medium model. The results show that BAR should be 3 to reduce the influence of writing and reading ITIs, media noise, and additive white Gaussian noise in an assumed areal density of 4.61Tbpsi.

  11. Spectrometer sensitivity calibration in the extreme uv by means of branching ratios of magnetic dipole lines

    International Nuclear Information System (INIS)

    Denne, B.; Hinnov, E.

    1984-04-01

    Relative intensity measurements of various line pairs resulting from magnetic dipole transitions within the configurations s 2 p 2 and s 2 p 4 , in conjunction with calculated transition probabilities, have been used to determine the wavelength dependence of the sensitivity of a grazing incidence spectrometer, in the range 400 to 1000 A. Emissions from Cr XIX, Fe XXI, Ni XXI and XXIII, Cu XXIV, and Zr XXVII ions in PLT tokamak discharges were used for this purpose. Absolute sensitivity of the spectrometer at selected wavelengths had been determined by the traditional hydrogen, helium, carbon, and oxygen electric-dipole line pairs from the same discharges. Similar attempts to use transitions in the s 2 p 3 configurations in Cr XVIII, Zr XXVI, and Mo XXVIII ions resulted in significant discrepancies that are ascribed to uncertainties in the corresponding calculated transition probabilities

  12. 137Cs Inter-Plant Concentration Ratios Provide a Predictive Tool for Coral Atolls with Distinct Benefits Over Transfer Factors

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W L; Hamilton, T F; Bogen, K; Corado, C L; Kehl, S R

    2007-07-17

    Inter-plant concentration ratios (IPCR), [Bq g{sup -1} {sup 137}Cs in coral atoll tree food-crops/Bq g{sup -1} {sup 137}Cs in leaves of native plant species whose roots share a common soil volume], can replace transfer factors (TF) to predict {sup 137}Cs concentration in tree food-crops in a contaminated area with an aged source term. The IPCR strategy has significant benefits relative to TF strategy for such purposes in the atoll ecosystem. IPCR strategy applied to specific assessments takes advantage of the fact tree roots naturally integrate 137Cs over large volumes of soil. Root absorption of {sup 137}Cs replaces large-scale, expensive soil sampling schemes to reduce variability in {sup 137}Cs concentration due to inhomogeneous radionuclide distribution. IPCR [drinking-coconut meat (DCM)/Scaevola (SCA) and Tournefortia (TOU) leaves (native trees growing on all atoll islands)] are log normally distributed (LND) with geometric standard deviation (GSD) = 1.85. TF for DCM from Enewetak, Eneu, Rongelap and Bikini Atolls are LND with GSD's of 3.5, 3.0, 2.7, and 2.1, respectively. TF GSD for Rongelap copra coconut meat is 2.5. IPCR of Pandanus fruit to SCA and TOU leaves are LND with GSD = 1.7 while TF GSD is 2.1. Because IPCR variability is much lower than TF variability, relative sampling error of an IPCR field sample mean is up 6- to 10-fold lower than that of a TF sample mean if sample sizes are small (10 to 20). Other IPCR advantages are that plant leaf samples are collected and processed in far less time with much less effort and cost than soil samples.

  13. 137Cs inter-plant concentration ratios provide a predictive tool for coral atolls with distinct benefits over transfer factors

    International Nuclear Information System (INIS)

    Robison, William L.; Hamilton, Terry F.; Bogen, Kenneth T.; Conrado, Cynthia L.; Kehl, Steven R.

    2008-01-01

    Inter-plant concentration ratios (IPCR) [Bq g -1137 Cs in coral atoll tree food crops/Bq g -1137 Cs in leaves of native plant species whose roots share a common soil volume] can replace transfer factors (TF) to predict 137 Cs concentration in tree food crops in a contaminated area with an aged source term. The IPCR strategy has significant benefits relative to TF strategy for such purposes in the atoll ecosystem. IPCR strategy applied to specific assessments takes advantage of the fact that tree roots naturally integrate 137 Cs over large volumes of soil. Root absorption of 137 Cs replaces large-scale, expensive soil sampling schemes to reduce variability in 137 Cs concentration due to inhomogeneous radionuclide distribution. IPCR [drinking-coconut meat (DCM)/Scaevola (SCA) and Tournefortia (TOU) leaves (native trees growing on all atoll islands)] are log-normally distributed (LND) with geometric standard deviation (GSD) = 1.85. TF for DCM from Enewetak, Eneu, Rongelap and Bikini Atolls are LND with GSDs of 3.5, 3.0, 2.7, and 2.1, respectively. TF GSD for Rongelap copra coconut meat is 2.5. IPCR of Pandanus fruit to SCA and TOU leaves are LND with GSD = 1.7 while TF GSD is 2.1. Because IPCR variability is much lower than TF variability, relative sampling error of an IPCR field sample mean is up 6- to 10-fold lower than that of a TF sample mean if sample sizes are small (10-20). Other IPCR advantages are that plant leaf samples are collected and processed in far less time with much less effort and cost than soil samples

  14. In vitro evaluation of genotoxic effects under magnetic resonant coupling wireless power transfer.

    Science.gov (United States)

    Mizuno, Kohei; Shinohara, Naoki; Miyakoshi, Junji

    2015-04-07

    Wireless power transfer (WPT) technology using the resonant coupling phenomenon has been widely studied, but there are very few studies concerning the possible relationship between WPT exposure and human health. In this study, we investigated whether exposure to magnetic resonant coupling WPT has genotoxic effects on WI38VA13 subcloned 2RA human fibroblast cells. WPT exposure was performed using a helical coil-based exposure system designed to transfer power with 85.4% efficiency at a 12.5-MHz resonant frequency. The magnetic field at the positions of the cell culture dishes is approximately twice the reference level for occupational exposure as stated in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. The specific absorption rate at the positions of the cell culture dishes matches the respective reference levels stated in the ICNIRP guidelines. For assessment of genotoxicity, we studied cell growth, cell cycle distribution, DNA strand breaks using the comet assay, micronucleus formation, and hypoxanthine-guanine phosphoribosyltransferase (HPRT) gene mutation, and did not detect any significant effects between the WPT-exposed cells and control cells. Our results suggest that WPT exposure under the conditions of the ICNIRP guidelines does not cause detectable cellular genotoxicity.

  15. In Vitro Evaluation of Genotoxic Effects under Magnetic Resonant Coupling Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Kohei Mizuno

    2015-04-01

    Full Text Available Wireless power transfer (WPT technology using the resonant coupling phenomenon has been widely studied, but there are very few studies concerning the possible relationship between WPT exposure and human health. In this study, we investigated whether exposure to magnetic resonant coupling WPT has genotoxic effects on WI38VA13 subcloned 2RA human fibroblast cells. WPT exposure was performed using a helical coil-based exposure system designed to transfer power with 85.4% efficiency at a 12.5-MHz resonant frequency. The magnetic field at the positions of the cell culture dishes is approximately twice the reference level for occupational exposure as stated in the International Commission on Non-Ionizing Radiation Protection (ICNIRP guidelines. The specific absorption rate at the positions of the cell culture dishes matches the respective reference levels stated in the ICNIRP guidelines. For assessment of genotoxicity, we studied cell growth, cell cycle distribution, DNA strand breaks using the comet assay, micronucleus formation, and hypoxanthine-guanine phosphoribosyltransferase (HPRT gene mutation, and did not detect any significant effects between the WPT-exposed cells and control cells. Our results suggest that WPT exposure under the conditions of the ICNIRP guidelines does not cause detectable cellular genotoxicity.

  16. Relation between Nd2Fe14B grain alignment and coercive force decrease ratio in NdFeB sintered magnets

    International Nuclear Information System (INIS)

    Matsuura, Yutaka; Hoshijima, Jun; Ishii, Rintaro

    2013-01-01

    It was found that the coercive force of NdFeB sintered magnets decreases as the Nd 2 Fe 14 B grain alignment improves. Because of this phenomenon, studies looked at the relation between this alignment and the coercive force decrease ratio. In experiments, it was expected that the coercive force of perfectly aligned magnet reached 0.7 of coercive force in istotropically aligned magnet. When it is postulated that the coercive force is determined by the Stoner–Wohlfarth model, coercive force increases as the alignment improves and it becomes difficult to explain our experimental data. On the other hand, when the coercive force is determined by magnetic domain wall motion, the coercive force decreases as the alignment improves and the coercive force of the perfectly aligned magnet reaches 1/√(2) of the isotropically aligned magnet. This tendency and value was very close to our data. It strongly suggests that the coercive force of NdFeB sintered magnets is determined by the domain wall motion. - Highlights: ► Coercive force of NdFeB sintered magnets decreases as grains alignment improves. ► Coercive force decrease ratio reaches −30% at the perfect aligned magnet. ►These experimental results are different from the Stoner–Wohlfarth model. ► The magnetic domain wall motion could explain this coercive force decrease ratio

  17. Relation between Nd{sub 2}Fe{sub 14}B grain alignment and coercive force decrease ratio in NdFeB sintered magnets

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yutaka, E-mail: Yutaka_Matsuura@hitachi-metals.co.jp [Hitachi Metals Ltd., NEOMAX Division, 2-15-17 Egawa, Shimamoto-cho, Mishima-gun, Osaka 618-0013 (Japan); Hoshijima, Jun; Ishii, Rintaro [Hitachi Metals Ltd., NEOMAX Division, 2-15-17 Egawa, Shimamoto-cho, Mishima-gun, Osaka 618-0013 (Japan)

    2013-06-15

    It was found that the coercive force of NdFeB sintered magnets decreases as the Nd{sub 2}Fe{sub 14}B grain alignment improves. Because of this phenomenon, studies looked at the relation between this alignment and the coercive force decrease ratio. In experiments, it was expected that the coercive force of perfectly aligned magnet reached 0.7 of coercive force in istotropically aligned magnet. When it is postulated that the coercive force is determined by the Stoner–Wohlfarth model, coercive force increases as the alignment improves and it becomes difficult to explain our experimental data. On the other hand, when the coercive force is determined by magnetic domain wall motion, the coercive force decreases as the alignment improves and the coercive force of the perfectly aligned magnet reaches 1/√(2) of the isotropically aligned magnet. This tendency and value was very close to our data. It strongly suggests that the coercive force of NdFeB sintered magnets is determined by the domain wall motion. - Highlights: ► Coercive force of NdFeB sintered magnets decreases as grains alignment improves. ► Coercive force decrease ratio reaches −30% at the perfect aligned magnet. ►These experimental results are different from the Stoner–Wohlfarth model. ► The magnetic domain wall motion could explain this coercive force decrease ratio.

  18. Limit on the muon neutrino magnetic moment and a measurement of the CCPIP to CCQE cross section ratio

    Energy Technology Data Exchange (ETDEWEB)

    Ouedraogo, Serge Aristide [Louisiana State Univ., Baton Rouge, LA (United States)

    2008-12-01

    A search for the muon neutrino magnetic moment was conducted using the Mini-BooNE low energy neutrino data. The analysis was performed by analyzing the elastic scattering interactions of muon neutrinos on electrons. The analysis looked for an excess of elastic scattering events above the Standard Model prediction from which a limit on the neutrino magnetic could be set. In this thesis, we report an excess of 15.3 ± 6.6(stat)±4.1(syst) vμe events above the expected background. At 90% C.L., we derived a limit on the muon neutrino magnetic moment of 12.7 x 10-10 μB. The other analysis reported in this thesis is a measurement of charged current single pion production (CCπ+) to charged current quasi elastic (CCQE) interactions cross sections ratio. This measurement was performed with two different fitting algorithms and the results from both fitters are consistent with each other.

  19. Expression of Heat Shock Proteins in Human Fibroblast Cells under Magnetic Resonant Coupling Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Kohei Mizuno

    2015-10-01

    Full Text Available Since 2007, resonant coupling wireless power transfer (WPT technology has been attracting attention and has been widely researched for practical use. Moreover, dosimetric evaluation has also been discussed to evaluate the potential health risks of the electromagnetic field from this WPT technology based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP guidelines. However, there has not been much experimental evaluation of the potential health risks of this WPT technology. In this study, to evaluate whether magnetic resonant coupling WPT induces cellular stress, we focused on heat shock proteins (Hsps and determined the expression level of Hsps 27, 70 and 90 in WI38VA13 subcloned 2RA human fibroblast cells using a western blotting method. The expression level of Hsps under conditions of magnetic resonant coupling WPT for 24 h was not significantly different compared with control cells, although the expression level of Hsps for cells exposed to heat stress conditions was significantly increased. These results suggested that exposure to magnetic resonant coupling WPT did not cause detectable cell stress.

  20. SPICE modelling of magnetic tunnel junctions written by spin-transfer torque

    Energy Technology Data Exchange (ETDEWEB)

    Guo, W; Prenat, G; De Mestier, N; Baraduc, C; Dieny, B [SPINTEC, UMR(8191), INAC, CEA/CNRS/UJF, 17 Av. des Martyrs, 38054 Grenoble Cedex 9 (France); Javerliac, V; El Baraji, M, E-mail: guillaume.prenat@cea.f [CROCUS Technology, 5 Place Robert Schuman, 38025 Grenoble (France)

    2010-06-02

    Spintronics aims at extending the possibility of conventional electronics by using not only the charge of the electron but also its spin. The resulting spintronic devices, combining the front-end complementary metal oxide semiconductor technology of electronics with a magnetic back-end technology, employ magnetic tunnel junctions (MTJs) as core elements. With the intent of simulating a circuit without fabricating it first, a reliable MTJ electrical model which is applicable to the standard SPICE (Simulation Program with Integrated Circuit Emphasis) simulator is required. Since such a model was lacking so far, we present a MTJ SPICE model whose magnetic state is written by using the spin-transfer torque effect. This model has been developed in the C language and validated on the Cadence Virtuoso Platform with a Spectre simulator. Its operation is similar to that of the standard BSIM (Berkeley Short-channel IGFET Model) SPICE model of the MOS transistor and fully compatible with the SPICE electrical simulator. The simulation results obtained using this model have been found in good accord with those theoretical macrospin calculations and results.

  1. Acrylamide-b-N-isopropylacrylamide block copolymers : Synthesis by atomic transfer radical polymerization in water and the effect of the hydrophilic-hydrophobic ratio on the solution properties

    NARCIS (Netherlands)

    Wever, Diego Armando Z.; Ramalho, Graham; Picchioni, Francesco; Broekhuis, Antonius Augustinus

    2014-01-01

    A series of block copolymers of acrylamide and N-isopropylacrylamide (NIPAM) characterized by different ratios between the length of the two blocks have been prepared through atomic transfer radical polymerization in water at room temperature. The solution properties of the block copolymers were

  2. A magnetization transfer imaging study of bilateral optic radiation and visual cortex in patients with primary glaucoma

    International Nuclear Information System (INIS)

    Liang Wenwen; Zhang Xuelin; Jiang Xiaoyong; Xu Yongming; Yang Zhihui; Zhang Yan; Chang Renmin; Wang Jianping; Wu Guijun

    2012-01-01

    Objective: To analyse the changes in bilateral optic radiation and visual cortex in patients with primary glaucoma detected by magnetization transfer imaging (MTI), and try to explore the influence of the disease on posterior visual pathway. Methods: MTI was performed in 20 patients with primary glaucoma with normal signal on conventional magnetic resonance imaging (MRI). The same scanning was performed in 31 matched healthy controls. MTI was obtained using spoiled gradient recalled acquisition sequence (SPGR). Magnetization transfer ratio (MTR) of bilateral optic radiation and visual cortex was measured after post-processing. The MTR value differences of the same area between two groups were compared by independent-sample t test or Satterthwaite t test if variances were not equality. Result: The MTR value in the left and right optic radiation were (32.8 ± 2.2)% and (32.7 ± 2.0)% in the glaucoma group, (34.6 ± 1.4 )% and (34.8 ± 1.3)% in the control group. There was a statistically significant difference between the two groups (left t=3.284, right t=4.040; P<0.01). The MTR value of the left and right visual cortex were (30.1± 2.0)% and (30.8 ± 1.8)% in the glaucoma group, and (32.3 ± 1.2 )% and (32.4 ± 1.2)% in the control group. Statistically significant difference was found between the two groups (left t=4.319, right t=3.445; P<0.01). Conclusions: Potential neuropathology changes occurring in the posterior visual pathway of patients with glaucoma indicate that the whole visual pathway may be involved by glaucoma.The micro physiological changes can be detected by MTI which can not be found by conventional MRI. It is a useful method of studying trans-synaptic damage of visual pathway n vivo glaucoma which provides more information for guiding the clinic diagnosis, cure and prognosis of glaucoma. (authors)

  3. Numerical Simulation of Flow and Heat Transfer in Structured Packed Beds with Smooth or Dimpled Spheres at Low Channel to Particle Diameter Ratio

    Directory of Open Access Journals (Sweden)

    Shiyang Li

    2018-04-01

    Full Text Available Packed beds are widely used in catalytic reactors or nuclear reactors. Reducing the pressure drop and improving the heat transfer performance of a packed bed is a common research aim. The dimpled structure has a complex influence on the flow and heat transfer characteristics. In the present study, the flow and heat transfer characteristics in structured packed beds with smooth or dimpled spheres are numerically investigated, where two different low channel to particle diameter ratios (N = 1.00 and N = 1.15 are considered. The pressure drop and the Nusselt number are obtained. The results show that, for N = 1.00, compared with the structured packed bed with smooth spheres, the structured packed bed with dimpled spheres has a lower pressure drop and little higher Nusselt number at 1500 < ReH < 14,000, exhibiting an improved overall heat transfer performance. However, for N = 1.15, the structured packed bed with dimpled spheres shows a much higher pressure drop, which dominantly affects the overall heat transfer performance, causing it to be weaker. Comparing the different channel to particle diameter ratios, we find that different configurations can result in: (i completely different drag reduction effect; and (ii relatively less influence on heat transfer enhancement.

  4. Quantification of the magnetization-transfer contrast effect: can it yield additional information in differentiation of musculoskeletal lesions particularly in separation of benign from malignant lesions

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Traeber, F.; Schild, H.; Gieseke, J.

    1999-01-01

    Purpose: To investigate the potential information of the amount of magnetization-transfer effect in musculoskeletal lesions and to compare MT ratios from benign and malignant musculoskeletal lesions. Material and Method: 49 patients with malignant tumors (3 osteosarcoma, 3 malignant fibrous histiocytoma, 4 chondrosarcoma, 2 Ewing sarcomas) and benign lesions (8 chondroma, 2 fibrous dysplasia, 3 osteoid-osteoma, 6 ganglion cyst, 3 cyst, 3 osteomyelitis, 4 tendinitis, 3 rotator cuff tear, 5 scar tissue) were scanned using routine MRI protocols including T 1 - and T 2 -weighted spin echo as well as T 2 *-weighted gradient echo (FFE) sequences at 1.5 Tesla (ACS II, Philips Medical). Additionally MTC images were generated by combining the FFE sequence and the off-resonance MT technique (-1500 Hz off-resonance frequency, 1770 flip angle and 50 ms pulse duration). MT ratios were calculated as SI o -SI m /SI o . Results: The MT ratio of benign lesions was 26±15%, that of malignant lesions was 22±6%. The difference was statistically not significant. As expected muscle showed a high MT ratio of 50±8%. Scar tissue demonstrated an MT ratio of 39±16% which was significantly higher than the tumor MT ratios. Conclusion: MTC (MT ratios) failed to show significant differences between benign and malignant lesions as was expected due to basic differences in cellularity, rate of mitosis and chromatin content. MTC might however gain more importance in separating scar tissue from recurrent tumor in the future. (orig.) [de

  5. State diagram of a perpendicular magnetic tunnel junction driven by spin transfer torque: A power dissipation approach

    Energy Technology Data Exchange (ETDEWEB)

    Lavanant, M. [Institut Jean Lamour, UMR CNRS 7198 – Université de Lorraine, Nancy (France); Department of Physics, New York University, New York, NY 10003 (United States); Petit-Watelot, S. [Institut Jean Lamour, UMR CNRS 7198 – Université de Lorraine, Nancy (France); Kent, A.D. [Department of Physics, New York University, New York, NY 10003 (United States); Mangin, S., E-mail: stephane.mangin@univ-lorraine.fr [Institut Jean Lamour, UMR CNRS 7198 – Université de Lorraine, Nancy (France)

    2017-04-15

    The state diagram of a magnetic tunnel junction with perpendicularly magnetized electrodes in the presence of spin-transfer torques is computed in a macrospin approximation using a power dissipation model. Starting from the macrospin's energy we determine the stability of energy extremum in terms of power received and dissipated, allowing the consideration of non-conservative torques associated with spin transfer and damping. The results are shown to be in agreement with those obtained by direct integration of the Landau-Lifshitz-Gilbert-Slonczewski equation. However, the power dissipation model approach is faster and shows the reason certain magnetic states are stable, such as states that are energy maxima but are stabilized by spin transfer torque. Breaking the axial system, such as by a tilted applied field or tilted anisotropy, is shown to dramatically affect the state diagrams. Finally, the influence of a higher order uniaxial anisotropy that can stabilize a canted magnetization state is considered and the results are compared to experimental data. - Highlights: • Methods to compute state Diagram (Voltage Versus Field) for perpendicular Magnetic Tunnel Junctions. • Comparison between the conventional LLG model and a model based on Power dissipation to study magnetization reversal in magnetic tunnel junction.

  6. Investigating spin-transfer torques induced by thermal gradients in magnetic tunnel junctions by using micro-cavity ferromagnetic resonance

    Science.gov (United States)

    Cansever, H.; Narkowicz, R.; Lenz, K.; Fowley, C.; Ramasubramanian, L.; Yildirim, O.; Niesen, A.; Huebner, T.; Reiss, G.; Lindner, J.; Fassbender, J.; Deac, A. M.

    2018-06-01

    Similar to electrical currents flowing through magnetic multilayers, thermal gradients applied across the barrier of a magnetic tunnel junction may induce pure spin-currents and generate ‘thermal’ spin-transfer torques large enough to induce magnetization dynamics in the free layer. In this study, we describe a novel experimental approach to observe spin-transfer torques induced by thermal gradients in magnetic multilayers by studying their ferromagnetic resonance response in microwave cavities. Utilizing this approach allows for measuring the magnetization dynamics on micron/nano-sized samples in open-circuit conditions, i.e. without the need of electrical contacts. We performed first experiments on magnetic tunnel junctions patterned into 6  ×  9 µm2 ellipses from Co2FeAl/MgO/CoFeB stacks. We conducted microresonator ferromagnetic resonance (FMR) under focused laser illumination to induce thermal gradients in the layer stack and compared them to measurements in which the sample was globally heated from the backside of the substrate. Moreover, we carried out broadband FMR measurements under global heating conditions on the same extended films the microstructures were later on prepared from. The results clearly demonstrate the effect of thermal spin-torque on the FMR response and thus show that the microresonator approach is well suited to investigate thermal spin-transfer-driven processes for small temperatures gradients, far below the gradients required for magnetic switching.

  7. Live birth sex ratio after in vitro fertilization and embryo transfer in China--an analysis of 121,247 babies from 18 centers.

    Science.gov (United States)

    Bu, Zhiqin; Chen, Zi-Jiang; Huang, Guoning; Zhang, Hanwang; Wu, Qiongfang; Ma, Yanping; Shi, Juanzi; Xu, Yanwen; Zhang, Songying; Zhang, Cuilian; Zhao, Xiaoming; Zhang, Bo; Huang, Yuanhua; Sun, Zhengyi; Kang, Yuefan; Wu, Riran; Wu, Xueqing; Sun, Haixiang; Sun, Yingpu

    2014-01-01

    In order to study the impact of procedures of IVF/ICSI technology on sex ratio in China, we conducted this multi-center retrospective study including 121,247 babies born to 93,895 women in China. There were 62,700 male babies and 58,477 female babies, making the sex ratio being 51.8% (Male: Female  = 107:100). In univariate logistic regression analysis, sex ratio was imbalance toward females of 50.3% when ICSI was preformed compared to 47.7% when IVF was used (Pratio in IVF/ICSI babies was significantly higher toward males in transfers of blastocyst (54.9%) and thawed embryo (52.4%) when compared with transfers of cleavage stage embryo (51.4%) and fresh embryo (51.5%), respectively. Multiple delivery was not associated with sex ratio. However, in multivariable logistic regression analysis after controlling for related factors, only ICSI (adjusted OR =  .90, 95%CI: 0.88-0.93; Pratio in IVF/ICSI babies. In conclusion, the live birth sex ratio in IVF/ICSI babies was influenced by the use of ICSI, which may decrease the percentage of male offspring, or the use of blastocyst transfer, which may increase the percentage of male offspring.

  8. Inflow hemodynamics evaluated by using four-dimensional flow magnetic resonance imaging and the size ratio of unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Futami, Kazuya; Nambu, Iku; Kitabayashi, Tomohiro; Sano, Hiroki; Misaki, Kouichi; Uchiyama, Naoyuki; Nakada, Mitsutoshi

    2017-01-01

    Prediction of the rupture risk is critical for the identification of unruptured cerebral aneurysms (UCAs) eligible for invasive treatments. The size ratio (SR) is a strong morphological predictor for rupture. We investigated the relationship between the inflow hemodynamics evaluated on four-dimensional (4D) flow magnetic resonance (MR) imaging and the SR to identify specific characteristics related to UCA rupture. We evaluated the inflow jet patterns and inflow hemodynamic parameters of 70 UCAs on 4D flow MR imaging and compared them among 23 aneurysms with an SR ≥2.1 and 47 aneurysms with an SR ≤2.0. Based on the shape of inflow streamline bundles with a velocity ≥75% of the maximum flow velocity in the parent artery, the inflow jet patterns were classified as concentrated (C), diffuse (D), neck-limited (N), and unvisualized (U). The incidence of patterns C and N was significantly higher in aneurysms with an SR ≥2.1. The rate of pattern U was significantly higher in aneurysms with an SR ≤2.0. The maximum inflow rate and the inflow rate ratio were significantly higher in aneurysms with an SR ≥2.1. The SR affected the inflow jet pattern, the maximum inflow rate, and the inflow rate ratio of UCAs. In conjunction with the SR, inflow hemodynamic analysis using 4D flow MR imaging may contribute to the risk stratification for aneurysmal rupture. (orig.)

  9. Inflow hemodynamics evaluated by using four-dimensional flow magnetic resonance imaging and the size ratio of unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Futami, Kazuya [Matto-Ishikawa Central Hospital, Department of Neurosurgery, Hakusan, Ishikawa (Japan); Nambu, Iku; Kitabayashi, Tomohiro; Sano, Hiroki; Misaki, Kouichi; Uchiyama, Naoyuki; Nakada, Mitsutoshi [Kanazawa University School of Medicine, Department of Neurosurgery, Kanazawa, Ishikawa (Japan)

    2017-04-15

    Prediction of the rupture risk is critical for the identification of unruptured cerebral aneurysms (UCAs) eligible for invasive treatments. The size ratio (SR) is a strong morphological predictor for rupture. We investigated the relationship between the inflow hemodynamics evaluated on four-dimensional (4D) flow magnetic resonance (MR) imaging and the SR to identify specific characteristics related to UCA rupture. We evaluated the inflow jet patterns and inflow hemodynamic parameters of 70 UCAs on 4D flow MR imaging and compared them among 23 aneurysms with an SR ≥2.1 and 47 aneurysms with an SR ≤2.0. Based on the shape of inflow streamline bundles with a velocity ≥75% of the maximum flow velocity in the parent artery, the inflow jet patterns were classified as concentrated (C), diffuse (D), neck-limited (N), and unvisualized (U). The incidence of patterns C and N was significantly higher in aneurysms with an SR ≥2.1. The rate of pattern U was significantly higher in aneurysms with an SR ≤2.0. The maximum inflow rate and the inflow rate ratio were significantly higher in aneurysms with an SR ≥2.1. The SR affected the inflow jet pattern, the maximum inflow rate, and the inflow rate ratio of UCAs. In conjunction with the SR, inflow hemodynamic analysis using 4D flow MR imaging may contribute to the risk stratification for aneurysmal rupture. (orig.)

  10. Analysis of self-heating of thermally assisted spin-transfer torque magnetic random access memory

    Directory of Open Access Journals (Sweden)

    Austin Deschenes

    2016-11-01

    Full Text Available Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM. Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. In this work we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We compare self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. The highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ, most of the heat is dissipated on the lower potential side of the magnetic junction. This asymmetry in heating, which has also been observed experimentally, is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.

  11. Transfer

    DEFF Research Database (Denmark)

    Wahlgren, Bjarne; Aarkrog, Vibe

    Bogen er den første samlede indføring i transfer på dansk. Transfer kan anvendes som praksis-filosofikum. Den giver en systematisk indsigt til den studerende, der spørger: Hvordan kan teoretisk viden bruges til at reflektere over handlinger i situationer, der passer til min fremtidige arbejdsplads?...

  12. Relations Between Atherogenic Index of Plasma, Ratio of Small Dense Low Density Lipoprotein/Lecithin Cholesterol Acyl Transferase and Ratio of Small Dense Low Density Lipoprotein/Cholesteryl Ester Transfer Protein of Controlled and Uncontrolled Type 2 DM

    Directory of Open Access Journals (Sweden)

    Ellis Susanti

    2009-08-01

    Full Text Available BACKGROUND: Patients with Diabetes Melitus are proven to be prone to atherosclerosis and coronary heart disease, especially type 2 Diabetes Melitus (T2DM patient who have higher risk and mortality for cardiovascular risk factor. The Dyslipidemia condition is very common in T2DM as one of the risk factors. Diabetic dyslipidemia is marked by the increased triglyceride (TG, low HDL cholesterol (HDL-C, and increased small dense LDL and apolipoprotein B. Therefore the aim of this study is to assess the differential and correlation between Atherogenic Index of Plasma (AIP, ratio of small dense low density lipoprotein (sdLDL/lecithin cholesterol acyl transferase (LCAT and ratio of sdLDL/cholesteryl ester transfer protein (CETP of controlled and uncontrolled T2DM. METHODS: This study was observational with cross sectional design. In total of 72 patients with T2DM consist of 36 controlled and 36 uncontrolled, participated in this study. The serum TG, HDL-C, sdLDL, LCAT and CETP were examined in their relationship with to T2DM risk. RESULTS: The results of the study indicate that the AIP (p<0.001 increase controlled and uncontrolled T2DM and the ratio of sdLDL/CETP (p=0.004, odds ratio of AIP was 4 (95% CI: 1.501-10.658 and odds ratio of sdLDL/CETP ratio was 4 (95% CI: 1.501-10.658 in uncontrolled T2DM. CONCLUSIONS: This study showed that the AIP and ratio of small dense LDL/CETP had a significant correlation with the uncontrolled T2DM. The AIP and ratio of small dense LDL/CETP increase was found at the uncontrolled T2DM to be 4 times greater than the controlled T2DM. KEYWORDS: T2DM, atherosclerosis, atherogenic index of plasma, small dense LDL, LCAT, CETP, ratio of sdLDL/LCAT, ratio of sdLDL/CETP.

  13. Study of stream wise transverse magnetic fluid flow with heat transfer around an obstacle embedded in a porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Rashidi, S. [Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad 91775-1111 (Iran, Islamic Republic of); Dehghan, M. [Department of Mechanical Engineering, Semnan University, P.O. Box: 35196-45399, Semnan (Iran, Islamic Republic of); Ellahi, R., E-mail: rellahi@engr.ucr.edu [Department of Mathematics and Statistics, FBAS, IIUI, 44000 Islamabad (Pakistan); Department of Mechanical Engineering, Bourns Hall, University of California, Riverside, CA 92521 (United States); Riaz, M. [Department of QEC, National Defense University, E-9 Sector, 44000 Islamabad (Pakistan); Jamal-Abad, M.T. [Department of Mechanical Engineering, Semnan University, P.O. Box: 35196-45399, Semnan (Iran, Islamic Republic of)

    2015-03-15

    A mathematical model for two-dimensional fluid flow under the influence of stream wise transverse magnetic fields in laminar regime is simulated in this study. Heat transfer past a square diamond shaped porous obstacle is also taken into account. The attention is focused to investigate the effects of intensity and direction of magnetic field, Darcy and Reynolds numbers on the mechanism of convective heat transfer and flow structures. The Darcy–Brinkman–Forchheimer model along with the Maxwell equations is used. The nonlinear coupled equations using a finite volume approach (FVA) are solved numerically. The calculations are performed for different governing parameters such as Reynolds number, Nusselt number, Stuart number and Prandtl Number. The physical interpretation of velocity and isothermal contours is assigned through graphs. It is shown that the effects of a transverse magnetic field on flow behavior and heat transfer mechanism are more than that of the stream wise magnetic field. The configuration of streamlines and vorticity contours phenomena are also presented for porous diamond obstacle. Comparison of the numerical solutions with existing literature is also made. - Highlights: • This paper analyses two-dimensional fluid flow under the influence of stream wise transverse magnetic field. • Heat transfer past a square diamond shaped porous obstacle is taken into account. • The Darcy–Brinkman–Forchheimer model is used. • Finite volume approach is used to find numerical solutions. • The configuration of streamlines and vorticity contours phenomena are presented through graphs.

  14. Deterministic Generation of Quantum State Transfer Between Spatially Separated Single Molecule Magnets

    International Nuclear Information System (INIS)

    Song Peijun; Lue Xinyou; Huang Pei; Hao Xiangying; Yang Xiaoxue

    2010-01-01

    We propose a new scheme for realizing deterministic quantum state transfer (QST) between two spatially separated single molecule magnets (SMMs) with the framework of cavity quantum electrodynamics (QED). In the present scheme, two SMMs are trapped in two spatially separated optical cavities coupled by an optical fiber. Through strictly numerically simulating, we demonstrate that our scheme is robust with respect to the SMMs' spontaneous decay and fiber loss under the conditions of dispersive SMMs-field interaction and strong coupling of cavity fiber. In addition, we also discuss the influence of photon leakage out of cavities and show that our proposal is good enough to demonstrate the generation of QST with high fidelity utilizing the current experimental technology. The present investigation provides research opportunities for realizing QST between solid-state qubits and may result in a substantial impact on the progress of solid-state-based quantum communications network. (general)

  15. Optimization of output power and transmission efficiency of magnetically coupled resonance wireless power transfer system

    Science.gov (United States)

    Yan, Rongge; Guo, Xiaoting; Cao, Shaoqing; Zhang, Changgeng

    2018-05-01

    Magnetically coupled resonance (MCR) wireless power transfer (WPT) system is a promising technology in electric energy transmission. But, if its system parameters are designed unreasonably, output power and transmission efficiency will be low. Therefore, optimized parameters design of MCR WPT has important research value. In the MCR WPT system with designated coil structure, the main parameters affecting output power and transmission efficiency are the distance between the coils, the resonance frequency and the resistance of the load. Based on the established mathematical model and the differential evolution algorithm, the change of output power and transmission efficiency with parameters can be simulated. From the simulation results, it can be seen that output power and transmission efficiency of the two-coil MCR WPT system and four-coil one with designated coil structure are improved. The simulation results confirm the validity of the optimization method for MCR WPT system with designated coil structure.

  16. Reconnection at the earth's magnetopause - Magnetic field observations and flux transfer events

    Science.gov (United States)

    Russell, C. T.

    1984-01-01

    Theoretical models of plasma acceleration by magnetic-field-line reconnection at the earth magnetopause and the high-resolution three-dimensional plasma measurements obtained with the ISEE satellites are compared and illustrated with diagrams, graphs, drawings, and histograms. The history of reconnection theory and the results of early satellite observations are summarized; the thickness of the magnetopause current layer is discussed; problems in analyzing the polarization of current-layer rotation are considered; and the flux-transfer events responsible for periods of patchy reconnection are characterized in detail. The need for further observations and refinements of the theory to explain the initiation of reconnection and identify the mechanism determining whether it is patchy or steady-state is indicated.

  17. Magnetic resonant wireless power transfer for propulsion of implantable micro-robot

    Science.gov (United States)

    Kim, D.; Kim, M.; Yoo, J.; Park, H.-H.; Ahn, S.

    2015-05-01

    Recently, various types of mobile micro-robots have been proposed for medical and industrial applications. Especially in medical applications, a motor system for propulsion cannot easily be used in a micro-robot due to their small size. Therefore, micro-robots are usually actuated by controlling the magnitude and direction of an external magnetic field. However, for micro-robots, these methods in general are only applicable for moving and drilling operations, but not for the undertaking of various missions. In this paper, we propose a new micro-robot concept, which uses wireless power transfer to deliver the propulsion force and electric power simultaneously. The mechanism of Lorentz force generation and the coil design methodologies are explained, and validation of the proposed propulsion system for a micro-robot is discussed thorough a simulation and with actual measurements with up-scaled test vehicles.

  18. Effects of crystalline grain size and packing ratio of self-forming core/shell nanoparticles on magnetic properties at up to GHz bands

    International Nuclear Information System (INIS)

    Suetsuna, Tomohiro; Suenaga, Seiichi; Sakurada, Shinya; Harada, Koichi; Tomimatsu, Maki; Takahashi, Toshihide

    2011-01-01

    Self-forming core/shell nanoparticles of magnetic metal/oxide with crystalline grain size of less than 40 nm were synthesized. The nanoparticles were highly concentrated in an insulating matrix to fabricate a nanocomposite, whose magnetic properties were investigated. The crystalline grain size of the nanoparticles strongly influenced the magnetic anisotropy field, magnetic coercivity, relative permeability, and loss factor (tan δ=μ''/μ') at high frequency. The packing ratio of the magnetic metallic phase in the nanocomposite also influenced those properties. High permeability with low tan δ of less than 1.5% at up to 1 GHz was obtained in the case of the nanoparticles with crystalline grain size of around 15 nm with large packing ratio of the nanoparticles. - Research highlights: → Self-forming core/shell nanoparticles of magnetic metal/oxide were synthesized. → Crystalline grain size of the nanoparticle and its packing ratio were controlled. → Magnetic properties changed according to the size and packing ratio.

  19. Lattice Boltzmann simulation of natural convection heat transfer in an open enclosure filled with Cu–water nanofluid in a presence of magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Ahmed Kadhim, E-mail: ahmedkadhim7474@gmail.com [Department of Mechanical Engineering, College of Engineering, Babylon University, Babylon City (Iraq); Ashorynejad, Hamid Reza; Shikholeslami, Mohsen [Faculty of Mechanical Engineering, Babol University of Technology, Babol, Mazandaran, Islamic Republic of Iran (Iran, Islamic Republic of); Sivasankaran, S. [Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur 50603 (Malaysia)

    2014-03-15

    Highlights: • Convection very strong when Ra is high and Ha = 0. • Isotherms smooth when Ra is low and Ha is high. • Maximum stream function increases by adding nano-particle. • Flow circulation decreases when magnetic orientation angle increases. • Nusselt number ratio increases when Ra increases. - Abstract: In this paper magneto hydrodynamic (MHD) natural convection flow of Cu–water nanofluid in an open enclosure is investigated numerically using lattice Boltzmann method (LBM) scheme. The effective thermal conductivity and viscosity of nanofluid are calculated by the Maxwell–Garnetts (MG) and Brinkman models, respectively. In addition, the MDF model was used for simulating the effect of uniform magnetic field. The influence of pertinent parameters such as Hartmann number, nanoparticle volume fraction, Rayleigh number and the inclination of magnetic field on the flow and heat transfer characteristics have been examined. The results indicate that the absolute values of stream function decline significantly by increasing Hartmann numbers while these values rise by increasing Rayleigh numbers. Moreover, the results show that the solid volume fraction has a significant influence on stream function and heat transfer, depending on the value of Hartmann and Rayleigh numbers.

  20. Kalman Filtered Bio Heat Transfer Model Based Self-adaptive Hybrid Magnetic Resonance Thermometry.

    Science.gov (United States)

    Zhang, Yuxin; Chen, Shuo; Deng, Kexin; Chen, Bingyao; Wei, Xing; Yang, Jiafei; Wang, Shi; Ying, Kui

    2017-01-01

    To develop a self-adaptive and fast thermometry method by combining the original hybrid magnetic resonance thermometry method and the bio heat transfer equation (BHTE) model. The proposed Kalman filtered Bio Heat Transfer Model Based Self-adaptive Hybrid Magnetic Resonance Thermometry, abbreviated as KalBHT hybrid method, introduced the BHTE model to synthesize a window on the regularization term of the hybrid algorithm, which leads to a self-adaptive regularization both spatially and temporally with change of temperature. Further, to decrease the sensitivity to accuracy of the BHTE model, Kalman filter is utilized to update the window at each iteration time. To investigate the effect of the proposed model, computer heating simulation, phantom microwave heating experiment and dynamic in-vivo model validation of liver and thoracic tumor were conducted in this study. The heating simulation indicates that the KalBHT hybrid algorithm achieves more accurate results without adjusting λ to a proper value in comparison to the hybrid algorithm. The results of the phantom heating experiment illustrate that the proposed model is able to follow temperature changes in the presence of motion and the temperature estimated also shows less noise in the background and surrounding the hot spot. The dynamic in-vivo model validation with heating simulation demonstrates that the proposed model has a higher convergence rate, more robustness to susceptibility problem surrounding the hot spot and more accuracy of temperature estimation. In the healthy liver experiment with heating simulation, the RMSE of the hot spot of the proposed model is reduced to about 50% compared to the RMSE of the original hybrid model and the convergence time becomes only about one fifth of the hybrid model. The proposed model is able to improve the accuracy of the original hybrid algorithm and accelerate the convergence rate of MR temperature estimation.

  1. Computational study of fluid flow and heat transfer in composite packed beds of spheres with low tube to particle diameter ratio

    International Nuclear Information System (INIS)

    Yang, Jian; Wu, Jiangquan; Zhou, Lang; Wang, Qiuwang

    2016-01-01

    Highlights: • Flow and heat transfer in composite packed beds with low d_t/d_p_e are investigated. • The wall effect would be restrained with radially layered composite packing (RLM). • Heat flux and overall heat transfer efficiency can be improved with RLM packing. - Abstract: The effect of the tube wall on the fluid flow and heat transfer would be important in the packed bed with low tube to particle diameter ratio, which may lead to flow and temperature maldistributions inside, and the heat transfer performance may be lowered. In the present paper, the flow and heat transfer performances in both the composite and uniform packed beds of spheres with low tube to particle diameter were numerically investigated, where the composite packing means randomly packing with non-uniform spheres and the uniform packing means randomly packing with uniform spheres, including radially layered composite packing (RLM), axially layered composite packing (ALM), randomly composite packing (RCM) and randomly uniform packing (RPM). Both the composite and uniform packings were generated with discrete element method (DEM), and the influence of the wall effect on the flow and heat transfer in the packed beds were carefully studied and compared with each other. Firstly, it is found that, the wall effect on the velocity and temperature distributions in the randomly packed bed of uniform spheres (RPM) with low tube to particle diameter ratio were obvious. The average velocity of the near-tube-wall region is higher than that of the inner-tube region in the bed. When the tube wall is adiabatic, the average temperature of the near-tube-wall region is lower. With radially layered composite packing method (RLM), smaller pores would be formed close to the tube wall and big flow channels would be formed in the inner-tube region of the bed, which would be benefit to restrain the wall effect and improve heat transfer in the bed with low tube to particle diameter ratio. Furthermore, it is also

  2. Computational study of fluid flow and heat transfer in composite packed beds of spheres with low tube to particle diameter ratio

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jian, E-mail: yangjian81@mail.xjtu.edu.cn [Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Wu, Jiangquan [CSR Research of Electrical Technology and Material Engineering, Zhuzhou, Hunan 412001 (China); Zhou, Lang; Wang, Qiuwang [Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China)

    2016-04-15

    Highlights: • Flow and heat transfer in composite packed beds with low d{sub t}/d{sub pe} are investigated. • The wall effect would be restrained with radially layered composite packing (RLM). • Heat flux and overall heat transfer efficiency can be improved with RLM packing. - Abstract: The effect of the tube wall on the fluid flow and heat transfer would be important in the packed bed with low tube to particle diameter ratio, which may lead to flow and temperature maldistributions inside, and the heat transfer performance may be lowered. In the present paper, the flow and heat transfer performances in both the composite and uniform packed beds of spheres with low tube to particle diameter were numerically investigated, where the composite packing means randomly packing with non-uniform spheres and the uniform packing means randomly packing with uniform spheres, including radially layered composite packing (RLM), axially layered composite packing (ALM), randomly composite packing (RCM) and randomly uniform packing (RPM). Both the composite and uniform packings were generated with discrete element method (DEM), and the influence of the wall effect on the flow and heat transfer in the packed beds were carefully studied and compared with each other. Firstly, it is found that, the wall effect on the velocity and temperature distributions in the randomly packed bed of uniform spheres (RPM) with low tube to particle diameter ratio were obvious. The average velocity of the near-tube-wall region is higher than that of the inner-tube region in the bed. When the tube wall is adiabatic, the average temperature of the near-tube-wall region is lower. With radially layered composite packing method (RLM), smaller pores would be formed close to the tube wall and big flow channels would be formed in the inner-tube region of the bed, which would be benefit to restrain the wall effect and improve heat transfer in the bed with low tube to particle diameter ratio. Furthermore, it

  3. Bond-order potential for magnetic body-centered-cubic iron and its transferability

    Science.gov (United States)

    Lin, Yi-Shen; Mrovec, M.; Vitek, V.

    2016-06-01

    We derived and thoroughly tested a bond-order potential (BOP) for body-centered-cubic (bcc) magnetic iron that can be employed in atomistic calculations of a broad variety of crystal defects that control structural, mechanical, and thermodynamic properties of this technologically important metal. The constructed BOP reflects correctly the mixed nearly free electron and covalent bonding arising from the partially filled d band as well as the ferromagnetism that is actually responsible for the stability of the bcc structure of iron at low temperatures. The covalent part of the cohesive energy is determined within the tight-binding bond model with the Green's function of the Schrödinger equation determined using the method of continued fractions terminated at a sufficient level of the moments of the density of states. This makes the BOP an O (N ) method usable for very large numbers of particles. Only d d bonds are included explicitly, but the effect of s electrons on the covalent energy is included via their screening of the corresponding d d bonds. The magnetic part of the cohesive energy is included using the Stoner model of itinerant magnetism. The repulsive part of the cohesive energy is represented, as in any tight-binding scheme, by an empirical formula. Its functional form is physically justified by studies of the repulsion in face-centered-cubic (fcc) solid argon under very high pressure where the repulsion originates from overlapping s and p closed-shell electrons just as it does from closed-shell s electrons in transition metals squeezed into the ion core under the influence of the large covalent d bonding. Testing of the transferability of the developed BOP to environments significantly different from those of the ideal bcc lattice was carried out by studying crystal structures and magnetic states alternative to the ferromagnetic bcc lattice, vacancies, divacancies, self-interstitial atoms (SIAs), paths continuously transforming the bcc structure to

  4. Correlation between charge transfer and exchange coupling in carbon-based magnetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Anh Tuan, E-mail: tuanna@hus.edu.vn [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Science and Technology Department, Vietnam National University, Hanoi, 144 Xuan Thuy, Cau Giay, Hanoi (Viet Nam); Japan Advanced Institute of Science and Technology, 1-1, Asahidai, Nomi, Ishikawa, 923-1292 Japan (Japan); Nguyen, Van Thanh; Nguyen, Huy Sinh [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Pham, Thi Tuan Anh [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Faculty of Science, College of Hai Duong, Nguyen Thi Due, Hai Duong (Viet Nam); Do, Viet Thang [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Faculty of Science, Haiphong University, 171 Phan Dang Luu, Kien An, Hai Phong (Viet Nam); Dam, Hieu Chi [Japan Advanced Institute of Science and Technology, 1-1, Asahidai, Nomi, Ishikawa, 923-1292 Japan (Japan)

    2015-10-15

    Several forms of carbon-based magnetic materials, i.e. single radicals, radical dimers, and alternating stacks of radicals and diamagnetic molecules, have been investigated using density-functional theory with dispersion correction and full geometry optimization. Our calculated results demonstrate that the C{sub 31}H{sub 15} (R{sub 4}) radical has a spin of ½. However, in its [R{sub 4}]{sub 2} dimer structure, the net spin becomes zero due to antiferromagnetic spin-exchange between radicals. To avoid antiferromagnetic spin-exchange of identical face-to-face radicals, eight alternating stacks, R{sub 4}/D{sub 2m}/R{sub 4} (with m = 3-10), were designed. Our calculated results show that charge transfer (Δn) between R{sub 4} radicals and the diamagnetic molecule D{sub 2m} occurs with a mechanism of spin exchange (J) in stacks. The more electrons that transfer from R{sub 4} to D{sub 2m}, the stronger the ferromagnetic spin-exchange in stacks. In addition, our calculated results show that Δn can be tailored by adjusting the electron affinity (E{sub a}) of D{sub 2m}. The correlation between Δn, E{sub a}, m, and J is discussed. These results give some hints for the design of new ferromagnetic carbon-based materials.

  5. Three-dimensional numerical modelling of a magnetically deflected dc transferred arc in argon

    CERN Document Server

    Blais, A; Boulos, M I

    2003-01-01

    The aim of this work is to develop a numerical model for the deflection of dc transferred arcs using an external magnetic field as a first step into the modelling of industrial arc furnaces. The arc is deflected by the use of a conductor aligned parallel to the arc axis through which flows an electric current. The model is validated by comparing the results of axisymmetric calculations to modelling results from the scientific literature. The present model is found to be a good representation of the electric dc arc as differences with the literature are easily explained by model parameters such as the critical boundary conditions at the electrodes. Transferred arc cases exhibit the expected behaviour as the temperature T, the velocity v-vector and the electrical potential drop DELTA phi all increase with the arc current I and the argon flow rate Q. Three-dimensional geometry is implemented, enabling one to numerically deflect the arc. For the deflected arc cases, the deflection increases with the arc current I...

  6. Three-dimensional numerical modelling of a magnetically deflected dc transferred arc in argon

    International Nuclear Information System (INIS)

    Blais, A; Proulx, P; Boulos, M I

    2003-01-01

    The aim of this work is to develop a numerical model for the deflection of dc transferred arcs using an external magnetic field as a first step into the modelling of industrial arc furnaces. The arc is deflected by the use of a conductor aligned parallel to the arc axis through which flows an electric current. The model is validated by comparing the results of axisymmetric calculations to modelling results from the scientific literature. The present model is found to be a good representation of the electric dc arc as differences with the literature are easily explained by model parameters such as the critical boundary conditions at the electrodes. Transferred arc cases exhibit the expected behaviour as the temperature T, the velocity v-vector and the electrical potential drop Δφ all increase with the arc current I and the argon flow rate Q. Three-dimensional geometry is implemented, enabling one to numerically deflect the arc. For the deflected arc cases, the deflection increases with the arc current I and conductor current I conductor and decreases with the flow rate Q and x 0 , the arc-conductor distance. These deflection behaviours are explained using physical arguments

  7. Accelerating two-dimensional nuclear magnetic resonance correlation spectroscopy via selective coherence transfer

    Science.gov (United States)

    Ye, Qimiao; Chen, Lin; Qiu, Wenqi; Lin, Liangjie; Sun, Huijun; Cai, Shuhui; Wei, Zhiliang; Chen, Zhong

    2017-01-01

    Nuclear magnetic resonance (NMR) spectroscopy serves as an important tool for both qualitative and quantitative analyses of various systems in chemistry, biology, and medicine. However, applications of one-dimensional 1H NMR are often restrained by the presence of severe overlap among different resonances. The advent of two-dimensional (2D) 1H NMR constitutes a promising alternative by extending the crowded resonances into a plane and thereby alleviating the spectral congestions. However, the enhanced ability in discriminating resonances is achieved at the cost of extended experimental duration due to necessity of various scans with progressive delays to construct the indirect dimension. Therefore, in this study, we propose a selective coherence transfer (SECOT) method to accelerate acquisitions of 2D correlation spectroscopy by converting chemical shifts into spatial positions within the effective sample length and then performing an echo planar spectroscopic imaging module to record the spatial and spectral information, which generates 2D correlation spectrum after 2D Fourier transformation. The feasibility and effectiveness of SECOT have been verified by a set of experiments under both homogeneous and inhomogeneous magnetic fields. Moreover, evaluations of SECOT for quantitative analyses are carried out on samples with a series of different concentrations. Based on these experimental results, the SECOT may open important perspectives for fast, accurate, and stable investigations of various chemical systems both qualitatively and quantitatively.

  8. Measurements of the deuteron and proton magnetic form factors at large momentum transfers

    International Nuclear Information System (INIS)

    Bosted, P.E.; Katramatou, A.T.; Arnold, R.G.; Benton, D.; Clogher, L.; DeChambrier, G.; Lambert, J.; Lung, A.; Petratos, G.G.; Rahbar, A.; Rock, S.E.; Szalata, Z.M.; Debebe, B.; Frodyma, M.; Hicks, R.S.; Hotta, A.; Peterson, G.A.; Gearhart, R.A.; Alster, J.; Lichtenstadt, J.; Dietrich, F.; van Bibber, K.

    1990-01-01

    Measurements of the deuteron elastic magnetic structure function B(Q 2 ) are reported at squared four-momentum transfer values 1.20≤Q 2 ≤2.77 (GeV/c) 2 . Also reported are values for the proton magnetic form factor G Mp (Q 2 ) at 11 Q 2 values between 0.49 and 1.75 (GeV/c) 2 . The data were obtained using an electron beam of 0.5 to 1.3 GeV. Electrons backscattered near 180 degree were detected in coincidence with deuterons or protons recoiling near 0 degree in a large solid-angle double-arm spectrometer system. The data for B(Q 2 ) are found to decrease rapidly from Q 2 =1.2 to 2 (GeV/c) 2 , and then rise to a secondary maximum around Q 2 =2.5 (GeV/c) 2 . Reasonable agreement is found with several different models, including those in the relativistic impulse approximation, nonrelativistic calculations that include meson-exchange currents, isobar configurations, and six-quark configurations, and one calculation based on the Skyrme model. All calculations are very sensitive to the choice of deuteron wave function and nucleon form factor parametrization. The data for G Mp (Q 2 ) are in good agreement with the empirical dipole fit

  9. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis; Resonancia magnetica con contraste y transferencia de magnetizacion en el estudio seriado de pacientes con esclerosis multiple

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, A; Alonso, J; Cucurella, G; Nos, C; Tintore, M; Pedraza, S; Rio, J; Montalban, X [Hospital General i Universitari Vall d` Hebron. Barcelona (Spain)

    1998-12-31

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs.

  10. Efficient energy transfer and increase of energy density of magnetically charged flywheels

    International Nuclear Information System (INIS)

    Hinterdorfer, T.

    2014-01-01

    Flywheel Energy Storage Systems represent an ecologically and economically sustainable technology for decentralized energy storage. Compared to other storage technologies such as e.g. chemical accumulators, they offer longer life cycles without performance degradation over time and usage and need almost no systematic maintenance. Further, they are made of environmentally friendly materials. By means of the driving torque of an electric motor, the flywheel is accelerated and thus electrical energy is transformed to kinetic energy. The stored energy can be transfered back by the load torque of a generator when needed. Modern flywheel energy storage applications use magnetic bearings to minimize selfdischarge. To avoid bearing forces due to rotor eccentricity an unbalance control strategy is used. However, this leads to an off-centered run of the electric machines rotor which in turn generates undesirable forces. A force-compensating operation of the electric machine will minimize the influence on the magnetic bearings in the planned control scheme, thus increasing their efficiency. Different concepts will be developed and compared to each other by means of simulations. Validation of the simulation models is carried out on a specially constructed test setup under defined conditions. In addition, the electrical machine will be integrated into the concept of redundancy of the flywheel. A bearingless operation increases the reliability and enables a safe shutdown of the application in case of malfunction of the magnetic bearings. High strength composite materials are used to achieve high speeds. Based on existing results from past research activities, a disc-shaped rotor is optimized first. To increase material utilization and to maximize energy density a topology optimization is performed. Evolutionary and gradient based optimization algorithms are used. Thereby the unused strength potential of the material is exploited in order to increase the economic efficiency of

  11. Binary neutron star mergers and short gamma-ray bursts: Effects of magnetic field orientation, equation of state, and mass ratio

    Science.gov (United States)

    Kawamura, Takumu; Giacomazzo, Bruno; Kastaun, Wolfgang; Ciolfi, Riccardo; Endrizzi, Andrea; Baiotti, Luca; Perna, Rosalba

    2016-09-01

    We present fully general-relativistic magnetohydrodynamic simulations of the merger of binary neutron star (BNS) systems. We consider BNSs producing a hypermassive neutron star (HMNS) that collapses to a spinning black hole (BH) surrounded by a magnetized accretion disk in a few tens of ms. We investigate whether such systems may launch relativistic jets and hence power short gamma-ray bursts. We study the effects of different equations of state (EOSs), different mass ratios, and different magnetic field orientations. For all cases, we present a detailed investigation of the matter dynamics and of the magnetic field evolution, with particular attention to its global structure and possible emission of relativistic jets. The main result of this work is that we observe the formation of an organized magnetic field structure. This happens independently of EOS, mass ratio, and initial magnetic field orientation. We also show that those models that produce a longer-lived HMNS lead to a stronger magnetic field before collapse to a BH. Such larger fields make it possible, for at least one of our models, to resolve the magnetorotational instability and hence further amplify the magnetic field in the disk. However, by the end of our simulations, we do not (yet) observe a magnetically dominated funnel nor a relativistic outflow. With respect to the recent simulations of Ruiz et al. [Astrophys. J. 824, L6 (2016)], we evolve models with lower and more plausible initial magnetic field strengths and (for computational reasons) we do not evolve the accretion disk for the long time scales that seem to be required in order to see a relativistic outflow. Since all our models produce a similar ordered magnetic field structure aligned with the BH spin axis, we expect that the results found by Ruiz et al. (who only considered an equal-mass system with an ideal fluid EOS) should be general and—at least from a qualitative point of view—independent of the mass ratio, magnetic field

  12. Age-related changes in conventional and magnetization transfer MR imaging in elderly people: comparison with neurocognitive performance

    International Nuclear Information System (INIS)

    Lee, Ki Yeol; Kim, Taik Kun; Park, Min Kyu; Ko, Sung Yu; Song, In Chan; Cho, Ik Hwan

    2004-01-01

    This study was designed to compare three different measures of the elderly human brain; the magnetization transfer ratio (MTR) histogram, the percentage of brain parenchymal volume, and the volume of T2 hyperintense areas in terms of correlations with the study subjects'neurocognitive performance. Thirty-five healthy community-dwelling elderly volunteers aged 60-82 years underwent dual fast spin-echo (FSE) imaging and magnetization transfer imaging. A semi-automated technique was used to generate the MTR histogram, the brain parenchymal volume, and the T2 lesion volume. The subjects'neurocognitive performance was assessed by using the Korean-Mini Mental State Examination (K-MMSE) and additional tests. The peak height of the MTR (PHMTR), the percentage of brain parenchymal volume (PBV), and the normalized T2 lesion volume (T2LV) were compared between the normal group. (Z score on the K-MMSE ≥ -2, n=23) and the mild cognitive impairment group (Z score on the K-MMSE < -2, N=12), and these parameters were correlated with age and various neurocognitive performance scores. The PHMTR was significantly lower in the cognitively impaired subjects than the PHMTR in the normal subjects (ρ = 0.005). The PBV scores were lower in the cognitively impaired subjects than in the normal subjects (ρ = 0.02). The T2LV scores were significantly higher in the cognitively impaired subjects (ρ = 0.01). An inverse correlation was found between the PHMTR and T2LV (r = -0.747, ρ < 0.001), and also between the PBV and T2LV (r = -0.823, ρ < 0.001). A positive correlation was observed between the PHMTR and the PBV (r = 0.846, ρ < 0.001). Scores on the various neurocognitive tests were positively correlated with the PHMTR (6 of 7 items) and the PBV (5 of 7 items), and they were negatively correlated with the T2LV (5 of 7 items). Our findings of a correlation among the PBV, the T2LV, and the PHMTR suggest that MTR histograms and the PBV and T2LV can be used as a reliable method and valid

  13. Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF).

    Science.gov (United States)

    Cohen, Ouri; Huang, Shuning; McMahon, Michael T; Rosen, Matthew S; Farrar, Christian T

    2018-05-13

    To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging. We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the N α -amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms were made with different concentrations (25-100 mM) and pH (pH 4-6). The MRF acquisition schedule varied the saturation power randomly for 30 iterations (phantom: 0-6 μT; in vivo: 0-4 μT) with a total acquisition time of ≤2 min. The signal trajectories were pattern-matched to a large dictionary of signal trajectories simulated using the Bloch-McConnell equations for different combinations of exchange rate, exchangeable proton volume fraction, and water T 1 and T 2 relaxation times. The chemical exchange rates of the N α -amine protons of L-Arg were significantly (P exchange using saturation power method. Similarly, the L-Arg concentrations determined using MRF were significantly (P exchange rate was well fit (R 2  = 0.9186) by a base catalyzed exchange model. The amide proton exchange rate measured in rat brain cortex (34.8 ± 11.7 Hz) was in good agreement with that measured previously with the water exchange spectroscopy method (28.6 ± 7.4 Hz). The semi-solid proton volume fraction was elevated in white (12.2 ± 1.7%) compared to gray (8.1 ± 1.1%) matter brain regions in agreement with previous magnetization transfer studies. CEST-MRF provides a method for fast, quantitative CEST imaging. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Mass Transfer Process by Magneto-convection at a Solid-liquid Interface in a Heterogeneous Vertical Magnetic Field

    Science.gov (United States)

    Sugiyama, Atsushi; Morisaki, Shigeyoshi; Aogaki, Ryoichi

    2003-08-01

    When an external magnetic field is vertically imposed on a solid-liquid interface, the mass transfer process of a solute dissolving from or depositing on the interface was theoretically examined. In a heterogeneous vertical magnetic field, a material receives a magnetic force in proportion to the product of the magnetic susceptibility, the magnetic flux density B and its gradient (dB/dz). As the reaction proceeds, a diffusion layer of the solute with changing susceptibility is formed at the interface because of the difference of the the magnetic susceptibility on the concentration of the solute. In the case of an unstable condition where the dimensionless number of magneto-convection S takes a positive value, the magnetic force is applied to the layer and induces numerous minute convection cells. The mass transfer of the solute is thus accelerated, so that it is predicted that the mass flux increases with the 1/3rd order of B(dB/dz) and the 4/3rd order of the concentration. The experiment was then performed by measuring the rate of the dissolution of copper sulfate pentahydrate crystal in water.

  15. High Zn/Al ratios enhance dehydrogenation vs hydrogen transfer reactions of Zn-ZSM-5 catalytic systems in methanol conversion to aromatics

    DEFF Research Database (Denmark)

    Pinilla-Herrero, Irene; Borfecchia, Elisa; Holzinger, Julian

    2018-01-01

    suggest that catalytic activity is associated with [Zn(H2O)n(OH)]+ species located in the exchange positions of the materials with little or no contribution of ZnO or metallic Zn. The effect of Zn/Al ratio on their catalytic performance in methanol conversion to aromatics has been investigated. In all...... cases, higher Zn content causes an increase in the yield of aromatics while keeping the production of alkanes low. For similar Zn contents, high densities of Al sites favour the hydrogen transfer reactions and alkane formation whereas in samples with low Al contents, and thus higher Zn/Al ratio...

  16. Ruthenium supported on magnetic nanoparticles: An efficient and recoverable catalyst for hydrogenation of alkynes and transfer hydrogenation of carbonyl compounds

    Science.gov (United States)

    Ruthenium supported on surface modified magnetic nanoparticles (NiFe2O4) has been successfully synthesized and applied for hydrogenation of alkynes at room temperature as well as transfer hydrogenation of a number of carbonyl compounds under microwave irradiation conditions. The ...

  17. Performance analysis and experimental verification of mid-range wireless energy transfer through non-resonant magnetic coupling

    DEFF Research Database (Denmark)

    Peng, Liang; Wang, Jingyu; Zhejiang University, Hangzhou, China, L.

    2011-01-01

    In this paper, the efficiency analysis of a mid-range wireless energy transfer system is performed through non-resonant magnetic coupling. It is shown that the self-resistance of the coils and the mutual inductance are critical in achieving a high efficiency, which is indicated by our theoretical...

  18. Magnetic nickel ferrite nanoparticles as highly durable catalysts for catalytic transfer hydrogenation of bio-based aldehydes

    DEFF Research Database (Denmark)

    He, Jian; Yang, Song; Riisager, Anders

    2018-01-01

    Magnetic nickel ferrite (NiFe2O4) nanoparticles were exploited as stable and easily separable heterogeneous catalysts for catalytic transfer hydrogenation (CTH) of furfural to furfuryl alcohol with 2-propanol as both the hydrogen source and the solvent providing 94% product yield at 180 degrees C...

  19. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  20. Heat transfer effects on a viscous dissipative fluid flow past a vertical plate in the presence of induced magnetic field

    Directory of Open Access Journals (Sweden)

    M.C. Raju

    2015-03-01

    Full Text Available A theoretical analysis is performed to study induced magnetic field effects on free convection flow past a vertical plate. The x¯-axis is taken vertically upwards along the plate, y¯-axis normal to the plate into the fluid region. It is assumed that the plate is electrically non-conducting and the applied magnetic field is of uniform strength (H0 and perpendicular to the plate. The magnetic Reynolds number of the flow is not taken to be small enough so that the induced magnetic field is taken into account. The coupled nonlinear partial differential equations are solved by Perturbation technique and the effects of various physical parameters on velocity, temperature, and induced magnetic fields are studied through graphs and tables. Variations in Skin friction and rate of heat transfer are also studied. It is observed that an increase in magnetic parameter decreases the velocity for both water and air. It is also seen that there is a fall in induced magnetic field as magnetic Prandtl number, and magnetic field parameter increase.

  1. Effect of Coriolis and centrifugal forces on flow and heat transfer at high rotation number and high density ratio in non orthogonally internal cooling channel

    Directory of Open Access Journals (Sweden)

    Brahim Berrabah

    2017-02-01

    Full Text Available Numerical predictions of three-dimensional flow and heat transfer are performed for a two-pass square channel with 45° staggered ribs in non-orthogonally mode-rotation using the second moment closure model. At Reynolds number of 25,000, the rotation numbers studied were 0, 0.24, 0.35 and 1.00. The density ratios were 0.13, 0.23 and 0.50. The results show that at high buoyancy parameter and high rotation number with a low density ratio, the flow in the first passage is governed by the secondary flow induced by the rotation whereas the secondary flow induced by the skewed ribs was almost distorted. As a result the heat transfer rate is enhanced on both co-trailing and co-leading sides compared to low and medium rotation number. In contrast, for the second passage, the rotation slightly reduces the heat transfer rate on co-leading side at high rotation number with a low density ratio and degrades it significantly on both co-trailing and co-leading sides at high buoyancy parameter compared to the stationary, low and medium rotation numbers. The numerical results are in fair agreement with available experimental data in the bend region and the second passage, while in the first passage were overestimated at low and medium rotation numbers.

  2. Analysis on the power and efficiency in wireless power transfer system via coupled magnetic resonances

    Science.gov (United States)

    Liu, Mingjie

    2018-06-01

    The analysis of characteristics of the power and efficiency in wireless power transmission (WPT) system is the theoretical basis of magnetic coupling resonant wireless power transmission (MCR-WPT) technology. The electromagnetic field theory was employed to study the variation of the coupling degree of the two electromagnetic coils with the parameters of the coils. The equivalent circuit was used to analyze the influence of different factors on the transmission power and efficiency of the WPT system. The results show that there is an optimal radius ratio between the two coils, which makes the mutual inductance of the coils the largest. Moreover, when the WPT system operates in the under-coupling state, the transmission power of the system drops sharply, and there is a frequency splitting of the power when in the over-coupling state.

  3. Heat transfer and flow analysis of nanofluid flow between parallel plates in presence of variable magnetic field using HPM

    Energy Technology Data Exchange (ETDEWEB)

    Hatami, M., E-mail: m.hatami@tue.nl [Esfarayen University of Technology, Mechanical Engineering Department, Esfarayen, North Khorasan (Iran, Islamic Republic of); Jing, Dengwei; Song, Dongxing [International Research Center for Renewable Energy, State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi' an 710049 (China); Sheikholeslami, M.; Ganji, D.D. [Department of Mechanical Engineering, Babol University of Technology, Babol (Iran, Islamic Republic of)

    2015-12-15

    In this study, effect of variable magnetic field on nanofluid flow and heat transfer analysis between two parallel disks is investigated. By using the appropriate transformation for the velocity, temperature and concentration, the basic equations governing the flow, heat and mass transfer were reduced to a set of ordinary differential equations. These equations subjected to the associated boundary conditions were solved analytically using Homotopy perturbation method. The analytical investigation is carried out for different governing parameters namely: squeeze number, suction parameter, Hartmann number, Brownian motion parameter, thermophrotic parameter and Lewis number. Results show that Nusselt number has direct relationship with Brownian motion parameter and thermophrotic parameter but it is a decreasing function of squeeze number, suction parameter, Hartmann number and Lewis number. - Highlights: • Heat and mass transfer of nanofluids between parallel plates investigated. • A variable magnetic field is applied on the plates. • Governing equations are solved analytically. • Effects of physical parameters are discussed on the Nusselt number.

  4. Heat transfer and flow analysis of nanofluid flow between parallel plates in presence of variable magnetic field using HPM

    International Nuclear Information System (INIS)

    Hatami, M.; Jing, Dengwei; Song, Dongxing; Sheikholeslami, M.; Ganji, D.D.

    2015-01-01

    In this study, effect of variable magnetic field on nanofluid flow and heat transfer analysis between two parallel disks is investigated. By using the appropriate transformation for the velocity, temperature and concentration, the basic equations governing the flow, heat and mass transfer were reduced to a set of ordinary differential equations. These equations subjected to the associated boundary conditions were solved analytically using Homotopy perturbation method. The analytical investigation is carried out for different governing parameters namely: squeeze number, suction parameter, Hartmann number, Brownian motion parameter, thermophrotic parameter and Lewis number. Results show that Nusselt number has direct relationship with Brownian motion parameter and thermophrotic parameter but it is a decreasing function of squeeze number, suction parameter, Hartmann number and Lewis number. - Highlights: • Heat and mass transfer of nanofluids between parallel plates investigated. • A variable magnetic field is applied on the plates. • Governing equations are solved analytically. • Effects of physical parameters are discussed on the Nusselt number

  5. TRANSFER

    African Journals Online (AJOL)

    This paper reports on further studies on long range energy transfer between curcumine as donor and another thiazine dye, thionine, which is closely related to methylene blue as energy harvester (Figure 1). Since thionine is known to have a higher quantum yield of singlet oxygen sensitization than methylene blue [8], it is ...

  6. Base Flow and Heat Transfer Characteristics of a Four-Nozzle Clustered Rocket Engine: Effect of Nozzle Pressure Ratio

    Science.gov (United States)

    Nallasamy, R.; Kandula, M.; Duncil, L.; Schallhorn, P.

    2010-01-01

    The base pressure and heating characteristics of a four-nozzle clustered rocket configuration is studied numerically with the aid of OVERFLOW Navier-Stokes code. A pressure ratio (chamber pressure to freestream static pressure) range of 990 to 5,920 and a freestream Mach number range of 2.5 to 3.5 are studied. The qualitative trends of decreasing base pressure with increasing pressure ratio and increasing base heat flux with increasing pressure ratio are correctly predicted. However, the predictions for base pressure and base heat flux show deviations from the wind tunnel data. The differences in absolute values between the computation and the data are attributed to factors such as perfect gas (thermally and calorically perfect) assumption, turbulence model inaccuracies in the simulation, and lack of grid adaptation.

  7. 31P magnetization transfer measurements of Pi→ATP flux in exercising human muscle.

    Science.gov (United States)

    Sleigh, Alison; Savage, David B; Williams, Guy B; Porter, David; Carpenter, T Adrian; Brindle, Kevin M; Kemp, Graham J

    2016-03-15

    Fundamental criticisms have been made over the use of (31)P magnetic resonance spectroscopy (MRS) magnetization transfer estimates of inorganic phosphate (Pi)→ATP flux (VPi-ATP) in human resting skeletal muscle for assessing mitochondrial function. Although the discrepancy in the magnitude of VPi-ATP is now acknowledged, little is known about its metabolic determinants. Here we use a novel protocol to measure VPi-ATP in human exercising muscle for the first time. Steady-state VPi-ATP was measured at rest and over a range of exercise intensities and compared with suprabasal oxidative ATP synthesis rates estimated from the initial rates of postexercise phosphocreatine resynthesis (VATP). We define a surplus Pi→ATP flux as the difference between VPi-ATP and VATP. The coupled reactions catalyzed by the glycolytic enzymes GAPDH and phosphoglycerate kinase (PGK) have been shown to catalyze measurable exchange between ATP and Pi in some systems and have been suggested to be responsible for this surplus flux. Surplus VPi-ATP did not change between rest and exercise, even though the concentrations of Pi and ADP, which are substrates for GAPDH and PGK, respectively, increased as expected. However, involvement of these enzymes is suggested by correlations between absolute and surplus Pi→ATP flux, both at rest and during exercise, and the intensity of the phosphomonoester peak in the (31)P NMR spectrum. This peak includes contributions from sugar phosphates in the glycolytic pathway, and changes in its intensity may indicate changes in downstream glycolytic intermediates, including 3-phosphoglycerate, which has been shown to influence the exchange between ATP and Pi catalyzed by GAPDH and PGK. Copyright © 2016 the American Physiological Society.

  8. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  9. Quantitative chemical exchange saturation transfer (qCEST) MRI - omega plot analysis of RF-spillover-corrected inverse CEST ratio asymmetry for simultaneous determination of labile proton ratio and exchange rate.

    Science.gov (United States)

    Wu, Renhua; Xiao, Gang; Zhou, Iris Yuwen; Ran, Chongzhao; Sun, Phillip Zhe

    2015-03-01

    Chemical exchange saturation transfer (CEST) MRI is sensitive to labile proton concentration and exchange rate, thus allowing measurement of dilute CEST agent and microenvironmental properties. However, CEST measurement depends not only on the CEST agent properties but also on the experimental conditions. Quantitative CEST (qCEST) analysis has been proposed to address the limitation of the commonly used simplistic CEST-weighted calculation. Recent research has shown that the concomitant direct RF saturation (spillover) effect can be corrected using an inverse CEST ratio calculation. We postulated that a simplified qCEST analysis is feasible with omega plot analysis of the inverse CEST asymmetry calculation. Specifically, simulations showed that the numerically derived labile proton ratio and exchange rate were in good agreement with input values. In addition, the qCEST analysis was confirmed experimentally in a phantom with concurrent variation in CEST agent concentration and pH. Also, we demonstrated that the derived labile proton ratio increased linearly with creatine concentration (P analysis can simultaneously determine labile proton ratio and exchange rate in a relatively complex in vitro CEST system. Copyright © 2015 John Wiley & Sons, Ltd.

  10. In vivo 31P nuclear magnetic resonance saturation transfer measurements of phosphate exchange reactions in the yeast Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Campbell, S.L.; Jones, K.A.; Schulman, R.G.

    1985-01-01

    31 P saturation transfer techniques have been used to measure phosphate kinetics in the yeast Saccharomyces cerevisiae. The phosphate comsumption rate observed in acetate grown mid-log cells was combined with measurements of O 2 consumption to yield P/O ratios of 2.2 and 2.9, for cells respiring on glucose and ethanol, respectively. However, no phosphate consumption activity was observed in saturation transfer experiments on anaerobic glucose fed cells. The phosphate consumption rates measured by saturation transfer in cells respiring on glucose and ethanol was attributed to the unidirectional rates of mitochondrial ATP synthesis. (Auth.)

  11. Helium flow dynamics and heat transfer in a cable in conduit conductor of superconducting magnets: a review

    International Nuclear Information System (INIS)

    Vaghela, Hitensinh; Sarkar, Biswanath; Lakhera, Vikas

    2016-01-01

    Superconducting (SC) magnets with Cable in Conduit Conductor (CICC) winding, cooled by helium at 4 K temperature are employed for many applications which require high magnetic field and high current densities. The construction of CICC aims to maintain superconductivity state by optimization of various parameters, i.e., thermal stability, ratio of normal conductor to superconductor material, mechanical strength, low hydraulic impedance, current density, magnetic field, etc. The cryogenic thermal stability of the CICC is of prime importance for the safe, stable and reliable operation of SC magnets. The prediction of thermal and hydraulic behaviour of CICC in large SC magnets is difficult due to the complex geometry, variation of fluid properties, various heat in-flux incidences over the long length of CICC and a complex heat transport phenomenon. A systematic review of the thermal and hydraulic studies of CICC has been presented in the paper highlighting the challenges and opportunities for further improvement in its design and performance. (author)

  12. Evaluating Zeta Potential and the Calcite/Aragonite Ratio as Potential Success Indicators for Magnetic Water Treatment

    National Research Council Canada - National Science Library

    Lambert, Kevin

    1999-01-01

    The potential benefits of anti-scale magnetic treatment (AMT) are not realized or reliably predicted because the factors measuring performance of magnetic treatment have either not been identified or are poorly defined...

  13. Postcontrast T1-weighted brain magnetic resonance imaging in pediatric patients: comparison between postcontrast fat-suppression imaging and conventional T1-weighted or magnetization transfer imaging

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Goo, Hyun Woo

    2004-01-01

    We wished to assess the merits and weaknesses of postcontrast fat-suppression (FS) brain MR imaging in children for the evaluation of various enhancing lesions as compared with postcontrast conventional T1-weighted or magnetization transfer (MT) imaging. We reviewed the records of those patients with enhancing lesions on brain MR imaging who had undergone both FS imaging and one of the conventional T1-weighted or MT imaging as a post-contrast T1-weighted brain MR imaging. Thirty-one patients (21 male, 10 female; mean age, 8.7 years) with 38 enhancing lesions (18 intra-axial, 16 extra-axial and 4 orbital locations) were included in this study. There were 27 pairs of FS and conventional imagings, and 13 pairs of FS and MT imagings available for evaluation. Two radiologists visually assessed by consensus the lesions' conspicuity, and they also looked for the presence of flow or susceptibility artifacts in a total of 40 pairs of MR imagings. For 19 measurable lesions (14 pairs of FS and conventional T1-weighted imagings, 5 pairs of FS and MT imagings), the contrast ratios between the lesion and the normal brain ([SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared. Compared with conventional imaging, the lesion conspicuity on FS imaging was better in 10 cases (7 extra-axial lesions, 2 orbital lesions and 1 fat-containing intra-axial lesion), equal in 16 cases, and worse in one case. Compared with MT imaging, the lesion conspicuity on FS imaging was better in 3 cases (2 extra-axial lesions and 1 intra-axial lesion), equal in 8 cases, and worse in 2 cases. Image quality of FS imaging was compromised by flow or susceptibility artifacts for 7 patients. The contrast ratios for FS imaging were not significantly different from those for conventional imaging (2.2±0.7 vs. 2.2±0.6, respectively, p=0.914) and they were significantly lower than those for MT imaging (2.4±0.8 vs. 4.5±1.5, respectively, p=0.018). Postcontrast FS brain MR imaging appears to be

  14. Parameters of glucose metabolism and the aging brain: a magnetization transfer imaging study of brain macro- and micro-structure in older adults without diabetes.

    Science.gov (United States)

    Akintola, Abimbola A; van den Berg, Annette; Altmann-Schneider, Irmhild; Jansen, Steffy W; van Buchem, Mark A; Slagboom, P Eline; Westendorp, Rudi G; van Heemst, Diana; van der Grond, Jeroen

    2015-08-01

    Given the concurrent, escalating epidemic of diabetes mellitus and neurodegenerative diseases, two age-related disorders, we aimed to understand the relation between parameters of glucose metabolism and indices of pathology in the aging brain. From the Leiden Longevity Study, 132 participants (mean age 66 years) underwent a 2-h oral glucose tolerance test to assess glucose tolerance (fasted and area under the curve (AUC) glucose), insulin sensitivity (fasted and AUC insulin and homeostatic model assessment of insulin sensitivity (HOMA-IS)) and insulin secretion (insulinogenic index). 3-T brain MRI was used to detect macro-structural damage (atrophy, white matter hyper-intensities, infarcts and/or micro-bleeds) and magnetization transfer imaging (MTI) to detect loss of micro-structural homogeneity that remains otherwise invisible on conventional MRI. Macro-structurally, higher fasted glucose was significantly associated with white matter atrophy (P = 0.028). Micro-structurally, decreased magnetization transfer ratio (MTR) peak height in gray matter was associated with higher fasted insulin (P = 0.010), AUCinsulin (P = 0.001), insulinogenic index (P = 0.008) and lower HOMA-IS index (P glucose was associated with macro-structural damage, impaired insulin action was associated more strongly with reduced micro-structural brain parenchymal homogeneity. These findings offer some insight into the association between different parameters of glucose metabolism (impairment of which is characteristic of diabetes mellitus) and brain aging.

  15. Pulsed magnetization transfer contrast MRI by a sequence with water selective excitation

    Energy Technology Data Exchange (ETDEWEB)

    Schick, F. [Univ. of Tuebingen (Germany)

    1996-01-01

    A water selective SE imaging sequence was developed providing suitable properties for the assessment of magnetization transfer (MT) effects in tissues with considerable amounts of fat. The sequence with water selective excitation and slice selective refocusing combines the following features: The RIF exposure on the macromolecular protons is relatively low for single slice imaging without MT prepulses, since no additional pulses for fat saturation are necessary. Water selection by frequency selective excitation diminishes faults in the subtraction of images recorded with and without MT prepulses (which might arise from movements). High differences in the signal amplitudes from hyaline cartilage and muscle tissue were obtained comparing images recorded with irradiation of the series of prepulses for MT and those lacking MT prepulses. Utilizations of the described water selective approach for the assessment of MT effects in lesions of cartilage and bone are demonstrated. MT saturation was also examined in muscles with fatty degeneration of patients suffering from progressive muscular dystrophy. The described technique allows determination of MT effects with good precision in a single slice, especially in regions with dominating fat signals. 22 refs., 5 figs.

  16. Graphene Derivative in Magnetically Recoverable Catalyst Determines Catalytic Properties in Transfer Hydrogenation of Nitroarenes to Anilines with 2-Propanol.

    Science.gov (United States)

    Das, Vijay Kumar; Mazhar, Sumaira; Gregor, Lennon; Stein, Barry D; Morgan, David Gene; Maciulis, Nicholas A; Pink, Maren; Losovyj, Yaroslav; Bronstein, Lyudmila M

    2018-06-14

    Here, we report transfer hydrogenation of nitroarenes to aminoarenes using 2-propanol as a hydrogen source and Ag-containing magnetically recoverable catalysts based on partially reduced graphene oxide (pRGO) sheets. X-ray diffraction and X-ray photoelectron spectroscopy data demonstrated that, during the one-pot catalyst synthesis, formation of magnetite nanoparticles (NPs) is accompanied by the reduction of graphene oxide (GO) to pRGO. The formation of Ag 0 NPs on top of magnetite nanoparticles does not change the pRGO structure. At the same time, the catalyst structure is further modified during the transfer hydrogenation, leading to a noticeable increase of sp 2 carbons. These carbons are responsible for the adsorption of substrate and intermediates, facilitating a hydrogen transfer from Ag NPs and creating synergy between the components of the catalyst. The nitroarenes with electron withdrawing and electron donating substituents allow for excellent yields of aniline derivatives with high regio and chemoselectivity, indicating that the reaction is not disfavored by these functionalities. The versatility of the catalyst synthetic protocol was demonstrated by a synthesis of an Ru-containing graphene derivative based catalyst, also allowing for efficient transfer hydrogenation. Easy magnetic separation and stable catalyst performance in the transfer hydrogenation make this catalyst promising for future applications.

  17. Dependences of the Tunnel Magnetoresistance and Spin Transfer Torque on the Sizes and Concentration of Nanoparticles in Magnetic Tunnel Junctions

    Science.gov (United States)

    Esmaeili, A. M.; Useinov, A. N.; Useinov, N. Kh.

    2018-01-01

    Dependences of the tunnel magnetoresistance and in-plane component of the spin transfer torque on the applied voltage in a magnetic tunnel junction have been calculated in the approximation of ballistic transport of conduction electrons through an insulating layer with embedded magnetic or nonmagnetic nanoparticles. A single-barrier magnetic tunnel junction with a nanoparticle embedded in an insulator forms a double-barrier magnetic tunnel junction. It has been shown that the in-plane component of the spin transfer torque in the double-barrier magnetic tunnel junction can be higher than that in the single-barrier one at the same thickness of the insulating layer. The calculations show that nanoparticles embedded in the tunnel junction increase the probability of tunneling of electrons, create resonance conditions, and ensure the quantization of the conductance in contrast to the tunnel junction without nanoparticles. The calculated dependences of the tunnel magnetoresistance correspond to experimental data demonstrating peak anomalies and suppression of the maximum magnetoresistances at low voltages.

  18. Magnetization transfer contrast (MTC) and MTC-subtraction: enhancement of cartilage lesions and intracartilaginous degeneration in vitro

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Dombrowski, F.; Leutner, C.; Wagner, U.; Reiser, M.

    1994-01-01

    Human articular cartilage from 16 cadaveric or amputated knees was studied using standard magnetic resonance imaging (MRI), on-resonance magnetization transfer contrast (MTC) and MTC-subtraction MRI. Results were compared with subsequent macroscopic and histopathological findings. MTC-subtraction and T2-weighted spin-echo images visualized cartilaginous surface defects with high sensitivity and specificity. MTC and T2-weighted spin-echo images revealed intra-cartilaginous signal loss without surface defects in 80% of the cases, corresponding to an increased collagen concentration. It is concluded that MTC is sensitive to early cartilage degeneration and MTC-subtraction can be helpful in detecting cartilage defects. (orig.)

  19. Amide Proton Transfer Magnetic Resonance Imaging of Alzheimer′s Disease at 3.0 Tesla: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2015-01-01

    Full Text Available Background: Amide proton transfer (APT imaging has recently emerged as an important contrast mechanism for magnetic resonance imaging (MRI in the field of molecular and cellular imaging. The aim of this study was to evaluate the feasibility of APT imaging to detect cerebral abnormality in patients with Alzheimer′s disease (AD at 3.0 Tesla. Methods: Twenty AD patients (9 men and 11 women; age range, 67-83 years and 20 age-matched normal controls (11 men and 9 women; age range, 63-82 years underwent APT and traditional MRI examination on a 3.0 Tesla MRI system. The magnetic resonance ratio asymmetry (MTR asym values at 3.5 ppm of bilateral hippocampi (Hc, temporal white matter regions, occipital white matter regions, and cerebral peduncles were measured on oblique axial APT images. MTR asym (3.5 ppm values of the cerebral structures between AD patients and control subjects were compared with independent samples t-test. Controlling for age, partial correlation analysis was used to investigate the associations between mini-mental state examination (MMSE and the various MRI measures among AD patients. Results: Compared with normal controls, MTR asym (3.5 ppm values of bilateral Hc were significantly increased in AD patients (right 1.24% ± 0.21% vs. 0.83% ± 0.19%, left 1.18% ± 0.18% vs. 0.80%± 0.17%, t = 3.039, 3.328, P = 0.004, 0.002, respectively. MTR asym (3.5 ppm values of bilateral Hc were significantly negatively correlated with MMSE (right r = −0.559, P = 0.013; left r = −0.461, P = 0.047. Conclusions: Increased MTR asym (3.5 ppm values of bilateral Hc in AD patients and its strong correlations with MMSE suggest that APT imaging could potentially provide imaging biomarkers for the noninvasive molecular diagnosis of AD.

  20. Experimental study on heat transfer enhancement of laminar ferrofluid flow in horizontal tube partially filled porous media under fixed parallel magnet bars

    Energy Technology Data Exchange (ETDEWEB)

    Sheikhnejad, Yahya; Hosseini, Reza, E-mail: hoseinir@aut.ac.ir; Saffar Avval, Majid

    2017-02-15

    In this study, steady state laminar ferroconvection through circular horizontal tube partially filled with porous media under constant heat flux is experimentally investigated. Transverse magnetic fields were applied on ferrofluid flow by two fixed parallel magnet bar positioned on a certain distance from beginning of the test section. The results show promising notable enhancement in heat transfer as a consequence of partially filled porous media and magnetic field, up to 2.2 and 1.4 fold enhancement were observed in heat transfer coefficient respectively. It was found that presence of both porous media and magnetic field simultaneously can highly improve heat transfer up to 2.4 fold. Porous media of course plays a major role in this configuration. Virtually, application of Magnetic field and porous media also insert higher pressure loss along the pipe which again porous media contribution is higher that magnetic field. - Highlights: • Porous media can improve the coefficient of heat transfer up to 2.2 fold. • Both porous media and Nano particles have undesired pressure drop effect. • Application of both porous media and magnetic field in ferrofluid flow will result in significant enhancement in heat transfer up to 2.4 fold. • Magnet bar effect is mainly restricted to approximately one fourth of the test section. • Diluted Ferrofluids 2%, results in over 1.4 fold enhancement in heat transfer coefficient.

  1. Electrically and magnetically controlled optical spanner based on the transfer of spin angular momentum of light in an optically active medium

    International Nuclear Information System (INIS)

    Chen Lixiang; Zheng Guoliang; She Weilong

    2007-01-01

    An optical spanner is a light beam that can exert a torque on an object. It is demonstrated in this Rapid Communication that, with the aid of applied electric and magnetic fields, a light beam with initially linear polarization and initially zero total spin angular momentum can interact with an optically active medium, resulting in a change of the ratio of left-handed circularly polarized photons to right-handed ones. Thus the total spin angular momentum of the light is changed, which leads to a torque, creating an electrically and magnetically controlled optical spanner on the medium. For a linearly polarized 632.8 nm laser beam incident on a 100-μm-long Ce:Bi 12 TiO 20 whisker crystal with 5 μm radius, if the magnetic field is fixed at -1.8 T, both the left- (right-)handed circularly polarized photon number and the total spin angular momentum vary with the applied electric field in a sinusoidal way, which means the torque exerted by the optical spanner on the crystal also varies sinusoidally with the electric field. It is found that at 50 (or-50) kV/cm, 56% right- (left-)handed circularly polarized photons are translated into left- (right-)handed ones, which corresponds to a transfer of 0.56(ℎ/2π) spin angular momentum contributed by each photon

  2. Characterisation of the Metabolites of 1,8-Cineole Transferred into Human Milk: Concentrations and Ratio of Enantiomers

    Science.gov (United States)

    Kirsch, Frauke; Buettner, Andrea

    2013-01-01

    1,8-Cineole is a widely distributed odorant that also shows physiological effects, but whose human metabolism has hitherto not been extensively investigated. The aim of the present study was, thus, to characterise the metabolites of 1,8-cineole, identified previously in human milk, after the oral intake of 100 mg of this substance. Special emphasis was placed on the enantiomeric composition of the metabolites since these data may provide important insights into potential biotransformation pathways, as well as potential biological activities of these substances, for example on the breastfed child. The volatile fraction of the human milk samples was therefore isolated via Solvent Assisted Flavour Evaporation (SAFE) and subjected to gas chromatography-mass spectrometry (GC-MS). The absolute concentrations of each metabolite were determined by matrix calibration with an internal standard, and the ratios of enantiomers were analysed on chiral capillaries. The concentrations varied over a broad range, from traces in the upper ng/kg region up to 40 µg/kg milk, with the exception of the main metabolite α2-hydroxy-1,8-cineole that showed concentrations of 100–250 µg/kg. Also, large inter- and intra-individual variations were recorded for the enantiomers, with nearly enantiomerically pure α2-hydroxy- and 3-oxo-1,8-cineole, while all other metabolites showed ratios of ~30:70 to 80:20. PMID:24957890

  3. Synthesis of multi-wavelength temporal phase-shifting algorithms optimized for high signal-to-noise ratio and high detuning robustness using the frequency transfer function

    OpenAIRE

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-01-01

    Synthesis of single-wavelength temporal phase-shifting algorithms (PSA) for interferometry is well-known and firmly based on the frequency transfer function (FTF) paradigm. Here we extend the single-wavelength FTF-theory to dual and multi-wavelength PSA-synthesis when several simultaneous laser-colors are present. The FTF-based synthesis for dual-wavelength PSA (DW-PSA) is optimized for high signal-to-noise ratio and minimum number of temporal phase-shifted interferograms. The DW-PSA synthesi...

  4. C2 Swan spectrum used as a molecular pyrometer in transferred arc and the influence noise to signal ratio on the temperature values

    International Nuclear Information System (INIS)

    Nassar, H

    2014-01-01

    The C 2 Swan system molecular emission spectrum is frequently observed in arc plasmas containing hydrocarbons. The spectra emitted from 5 kw in the transferred arc reactor at atmospheric pressure by CH 4 /CO 2 /Ar mixture are recorded with the help of an optical system consisting of a linear CCD array coupled with 2m spectrometer. The rotational temperature of 4300±300 K is found from the experimental Abel inverted spectra in the arc center after a point-to-point comparison of the spectrum with a computer simulated one. The influence of the noise to signal ratio has been studied, if the noise to signal ratio is about 10% we found an error of 7% at temperature 3000 K and 10% at 6000 K.

  5. Model-Assisted Control of Flow Front in Resin Transfer Molding Based on Real-Time Estimation of Permeability/Porosity Ratio

    Directory of Open Access Journals (Sweden)

    Bai-Jian Wei

    2016-09-01

    Full Text Available Resin transfer molding (RTM is a popular manufacturing technique that produces fiber reinforced polymer (FRP composites. In this paper, a model-assisted flow front control system is developed based on real-time estimation of permeability/porosity ratio using the information acquired by a visualization system. In the proposed control system, a radial basis function (RBF network meta-model is utilized to predict the position of the future flow front by inputting the injection pressure, the current position of flow front, and the estimated ratio. By conducting optimization based on the meta-model, the value of injection pressure to be implemented at each step is obtained. Moreover, a cascade control structure is established to further improve the control performance. Experiments show that the developed system successfully enhances the performance of flow front control in RTM. Especially, the cascade structure makes the control system robust to model mismatch.

  6. THE EFFECT OF A TWISTED MAGNETIC FIELD ON THE PERIOD RATIO P{sub 1}/P{sub 2} OF NONAXISYMMETRIC MAGNETOHYDRODYNAMIC WAVES

    Energy Technology Data Exchange (ETDEWEB)

    Karami, K. [Department of Physics, University of Kurdistan, Pasdaran Street, Sanandaj (Iran, Islamic Republic of); Bahari, K., E-mail: KKarami@uok.ac.ir, E-mail: K.Bahari@razi.ac.ir [Physics Department, Faculty of Science, Razi University, Kermanshah (Iran, Islamic Republic of)

    2012-10-01

    We consider nonaxisymmetric magnetohydrodynamic (MHD) modes in a zero-beta cylindrical compressible thin magnetic flux tube modeled as a twisted core surrounded by a magnetically twisted annulus, with both embedded in a straight ambient external field. The dispersion relation is derived and solved analytically and numerically to obtain the frequencies of the nonaxisymmetric MHD waves. The main result is that the twisted magnetic annulus does affect the period ratio P{sub 1}/P{sub 2} of the kink modes. For the kink modes, the magnetic twist in the annulus region can achieve deviations from P{sub 1}/P{sub 2} = 2 of the same order of magnitude as in the observations. Furthermore, the effect of the internal twist on the fluting modes is investigated.

  7. Magnetic field effect on nanoparticles migration and heat transfer of water/alumina nanofluid in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Malvandi, A., E-mail: amirmalvandi@aut.ac.ir [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), 424 Hafez Avenue, Tehran (Iran, Islamic Republic of); Ganji, D.D., E-mail: ddg_davood@yahoo.com [Mechanical Engineering Department, Babol Noshirvani University of Technology, Babol (Iran, Islamic Republic of)

    2014-08-01

    The present study is a theoretical investigation of the laminar flow and convective heat transfer of water/alumina nanofluid inside a parallel-plate channel in the presence of a uniform magnetic field. A modified two-component, four-equation, nonhomogeneous equilibrium model was employed for the alumina/water nanofluid, which fully accounted for the effect of the nanoparticle volume fraction distribution. The no-slip condition of the fluid–solid interface is abandoned in favor of a slip condition which appropriately represents the non-equilibrium region near the interface at micro/nano channels. The results obtained indicated that nanoparticles move from the heated walls (nanoparticles depletion) toward the core region of the channel (nanoparticles accumulation) and construct a non-uniform nanoparticles distribution. Moreover, in the presence of the magnetic field, the near wall velocity gradients increase, enhancing the slip velocity and thus the heat transfer rate and pressure drop increase. - Highlights: • Force convection of alumina/water nanofluid inside a parallel-plate channel. • Magnetic field effects on nanoparticles' migration. • Effects of Brownian motion and thermophoresis diffusivities on nanoparticle migration. • Different mechanisms of heat transfer rate based on nanoparticles' diameter.

  8. Wireless Energy Transfer Using Resonant Magnetic Induction for Electric Vehicle Charging Application

    Science.gov (United States)

    Dahal, Neelima

    The research work for this thesis is based on utilizing resonant magnetic induction for wirelessly charging electric vehicles. The background theory for electromagnetic induction between two conducting loops is given and it is shown that an RLCequivalent circuit can be used to model the loops. An analysis of the equivalent circuit is used to show how two loosely coupled loops can be made to exchange energy efficiently by operating them at a frequency which is the same as the resonant frequency of both. Furthermore, it is shown that the efficiency is the maximum for critical coupling (determined by the quality factors of the loops), and increasing the coupling beyond critical coupling causes double humps to appear in the transmission efficiency versus frequency spectrum. In the experiment, as the loops are brought closer together which increases the coupling between them, doubles humps, as expected from the equivalent circuit analysis is seen. Two models for wireless energy transfer are identified: basic model and array model. The basic model consists of the two loosely coupled loops, the transmitter and the receiver. The array model consists of a 2 x 2 array of the transmitter and three parasites, and the receiver. It is shown that the array model allows more freedom for receiver placement at the cost of degraded transmission efficiency compared to the basic model. Another important part of the thesis is software validation. HFSS-IE and 4NEC2 are the software tools used and the simulation results for wire antennas are compared against references obtained from a textbook and a PhD dissertation. It is shown that the simulations agree well with the references and also with each other.

  9. Heat Flux of a Transferred Arc Driven by a Transverse Magnetic Field

    Directory of Open Access Journals (Sweden)

    Naomi Matsumoto

    2009-01-01

    Full Text Available Theoretical consideration of a magnetically driven arc was performed to elucidate the variation of heat flux with an imposed DC magnetic field. Experiments were conducted to confirm the validity of the theoretical model. The heat flux decreased concomitantly with increased imposed magnetic flux density. Theoretical predictions agreed with experimental results.

  10. 3D magneto-convective heat transfer in CNT-nanofluid filled cavity under partially active magnetic field

    Science.gov (United States)

    Al-Rashed, Abdullah A. A. A.; Kolsi, Lioua; Oztop, Hakan F.; Aydi, Abdelkarim; Malekshah, Emad Hasani; Abu-Hamdeh, Nidal; Borjini, Mohamed Naceur

    2018-05-01

    A computational study has been performed to investigate the effects of partially active magnetic field on natural convection heat transfer in CNT-nanofluid filled and three-dimensional differentially heated closed space. Two cases are considered to see this effect as magnetic field is applied to upper half (Case I) and lower half (Case II) while remaining walls are insulated. The finite volume method is used to solve governing equations and results are obtained for different governing parameters as Hartmann number (0 ≤ Ha ≤ 100), nanoparticle volume fraction (0 ≤ φ ≤ 0.05) and height of the active zone (0 ≤ LB ≤ 1). It is found that location of magnetic field plays an important role even at the same Hartmann number. Thus, it can be a good parameter to control heat and fluid flow inside the closed space.

  11. Nuclear magnetic resonance study of charge transfer complex formation between Silver Nitrate and Benzylcyanide in Solvent Ethylene Glycol

    CERN Document Server

    Modarress, H

    2003-01-01

    The formation constant for charge transfer complexes between electron acceptor (AgNo sub 3) and electron donor benzylcyanide (C sub 6 H sub 5 -CH sub 2 -C ident to N) in solvent ethyleneglycol [(CH sub 2 OH) sub 2] has been evaluated by using the nuclear magnetic resonance chemical shifts of aromatic group of benzylcyanide measured against external references, tetramethylsilane, hexamethyldisilane and cyclohexane at 20 sup d ig sup C. The external referencing procedure eliminated the interference of internal reference in the course of complexation. The necessary bulk magnetic susceptibility corrections on the measured chemical shifts have been made. The solution nationalised and their effects on the formation constant have been considered and a new equation has been suggested to obtain the main ionic activity coefficient of AgNO sub 3 from nuclear magnetic resonance results. The mean ionic activity coefficient has been taken into account in the formation constant calculations. The results indicated that the a...

  12. Modelling of a linear PM machine including magnetic saturation and end effects : maximum force to current ratio

    NARCIS (Netherlands)

    Polinder, H.; Slootweg, J.G.; Hoeijmakers, M.J.; Compter, J.C.

    2003-01-01

    The use of linear permanent-magnet (PM) actuators increases in a wide variety of applications because of their high force density, robustness and accuracy. These linear PM motors are often heavily loaded during short intervals of high acceleration, so that magnetic saturation occurs. This paper

  13. A consistency evaluation of signal-to-noise ratio in the quality assessment of human brain magnetic resonance images.

    Science.gov (United States)

    Yu, Shaode; Dai, Guangzhe; Wang, Zhaoyang; Li, Leida; Wei, Xinhua; Xie, Yaoqin

    2018-05-16

    Quality assessment of medical images is highly related to the quality assurance, image interpretation and decision making. As to magnetic resonance (MR) images, signal-to-noise ratio (SNR) is routinely used as a quality indicator, while little knowledge is known of its consistency regarding different observers. In total, 192, 88, 76 and 55 brain images are acquired using T 2 * , T 1 , T 2 and contrast-enhanced T 1 (T 1 C) weighted MR imaging sequences, respectively. To each imaging protocol, the consistency of SNR measurement is verified between and within two observers, and white matter (WM) and cerebral spinal fluid (CSF) are alternately used as the tissue region of interest (TOI) for SNR measurement. The procedure is repeated on another day within 30 days. At first, overlapped voxels in TOIs are quantified with Dice index. Then, test-retest reliability is assessed in terms of intra-class correlation coefficient (ICC). After that, four models (BIQI, BLIINDS-II, BRISQUE and NIQE) primarily used for the quality assessment of natural images are borrowed to predict the quality of MR images. And in the end, the correlation between SNR values and predicted results is analyzed. To the same TOI in each MR imaging sequence, less than 6% voxels are overlapped between manual delineations. In the quality estimation of MR images, statistical analysis indicates no significant difference between observers (Wilcoxon rank sum test, p w  ≥ 0.11; paired-sample t test, p p  ≥ 0.26), and good to very good intra- and inter-observer reliability are found (ICC, p icc  ≥ 0.74). Furthermore, Pearson correlation coefficient (r p ) suggests that SNR wm correlates strongly with BIQI, BLIINDS-II and BRISQUE in T 2 * (r p  ≥ 0.78), BRISQUE and NIQE in T 1 (r p  ≥ 0.77), BLIINDS-II in T 2 (r p  ≥ 0.68) and BRISQUE and NIQE in T 1 C (r p  ≥ 0.62) weighted MR images, while SNR csf correlates strongly with BLIINDS-II in T 2 * (r p  ≥ 0.63) and in T

  14. Probing the Magnetic Field Structure in Sgr A* on Black Hole Horizon Scales with Polarized Radiative Transfer Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Gold, Roman; McKinney, Jonathan C. [Department of Physics and Joint Space-Science Institute, University of Maryland, College Park, MD 20742 (United States); Johnson, Michael D.; Doeleman, Sheperd S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-03-10

    Magnetic fields are believed to drive accretion and relativistic jets in black hole accretion systems, but the magnetic field structure that controls these phenomena remains uncertain. We perform general relativistic (GR) polarized radiative transfer of time-dependent three-dimensional GR magnetohydrodynamical simulations to model thermal synchrotron emission from the Galactic Center source Sagittarius A* (Sgr A*). We compare our results to new polarimetry measurements by the Event Horizon Telescope (EHT) and show how polarization in the visibility (Fourier) domain distinguishes and constrains accretion flow models with different magnetic field structures. These include models with small-scale fields in disks driven by the magnetorotational instability as well as models with large-scale ordered fields in magnetically arrested disks. We also consider different electron temperature and jet mass-loading prescriptions that control the brightness of the disk, funnel-wall jet, and Blandford–Znajek-driven funnel jet. Our comparisons between the simulations and observations favor models with ordered magnetic fields near the black hole event horizon in Sgr A*, though both disk- and jet-dominated emission can satisfactorily explain most of the current EHT data. We also discuss how the black hole shadow can be filled-in by jet emission or mimicked by the absence of funnel jet emission. We show that stronger model constraints should be possible with upcoming circular polarization and higher frequency (349 GHz) measurements.

  15. Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    Science.gov (United States)

    Sun, Phillip Zhe; Wang, Yu; Dai, ZhuoZhi; Xiao, Gang; Wu, Renhua

    2014-01-01

    Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitative CEST (qCEST) analysis. Towards this goal, it has been shown that omega plot is capable of quantifying paramagnetic CEST MRI. However, the use of the omega plot is somewhat limited for diamagnetic CEST (DIACEST) MRI because it is more susceptible to direct radio frequency (RF) saturation (spillover) owing to the relatively small chemical shift. Recently, it has been found that, for dilute DIACEST agents that undergo slow to intermediate chemical exchange, the spillover effect varies little with the labile proton ratio and exchange rate. Therefore, we postulated that the omega plot analysis can be improved if RF spillover effect could be estimated and taken into account. Specifically, simulation showed that both labile proton ratio and exchange rate derived using the spillover effect-corrected omega plot were in good agreement with simulated values. In addition, the modified omega plot was confirmed experimentally, and we showed that the derived labile proton ratio increased linearly with creatine concentration (p plot for quantitative analysis of DIACEST MRI. Copyright © 2014 John Wiley & Sons, Ltd.

  16. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO3 nanowires with high length–diameter ratio

    International Nuclear Information System (INIS)

    Liu, Hui; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-01-01

    WO 3 nanowires (WO 3 NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO 3 NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO 3 NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO 3 nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO 3 nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO 3 NWs with high length–diameter ratio have been synthesized. • The WO 3 NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite

  17. Study of the effect of distance and misalignment between magnetically coupled coils for wireless power transfer in intraocular pressure measurement.

    Science.gov (United States)

    Rendon-Nava, Adrian E; Díaz-Méndez, J Alejandro; Nino-de-Rivera, Luis; Calleja-Arriaga, Wilfrido; Gil-Carrasco, Felix; Díaz-Alonso, Daniela

    2014-01-01

    An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  18. Study of the Effect of Distance and Misalignment between Magnetically Coupled Coils for Wireless Power Transfer in Intraocular Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Adrian E. Rendon-Nava

    2014-01-01

    Full Text Available An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  19. A 99%-efficiency GaN converter for 6.78 MHz magnetic resonant wireless power transfer system

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Akuzawa

    2014-10-01

    Full Text Available The authors developed a high-efficiency gallium-nitride (GaN Class-E converter for a 6.78 MHz magnetic resonant wireless power transfer system. A negative-bias gate driver circuit made it possible to use a depletion mode GaN high-electron-mobility transistor (HEMT, and simplified the converter circuit. As the depletion mode GaN HEMT with very small gate–source capacitance provided almost ideal zero-voltage switching, the authors attained a drain efficiency of 98.8% and a total efficiency of 97.7%, including power consumption of a gate driver circuit, at a power output of 33 W. In addition, the authors demonstrated a 6.78 MHz magnetic resonant wireless power transfer system that consisted of the GaN Class-E converter, a pair of magnetic resonant coils 150 mm in diameter with an air-gap distance of 40 mm, and a full-bridge rectifier using Si Schottky barrier diodes. The system achieved a dc–dc efficiency of 82.8% at a power output of 25 W. The efficiencies of coil coupling and the rectifier were estimated to be ∼ 94 and 90%, respectively.

  20. Ratio of spin transfer parameters dt/rt in d(p vector, n vector)pp quasi-elastic scattering

    International Nuclear Information System (INIS)

    Abegg, R.; Green, W.; Greeniaus, L.G.; Miller, C.A.; Bardyopadhyay, D.; Birchall, J.; Davis, C.A.; Davison, N.E.; Page, S.A.; Ramsay, W.D.; van Oers, W.T.H.; Lapointe, C.; Moss, G.A.; Tkachuk, R.R.

    1988-05-01

    The ratio of spin transfer parameters d t /r t for the quasi-elastic process d(p,n)pp has been measured at four energies between 200 and 500 MeV at a neutron scattering angle of 9 degrees. From this, the following values of D t /R t for free np scattering have been deduced: -0.0190 ± 0.0072 (T p = 223 MeV); -0.2328 ± 0.0057 (324 MeV); -0.3731 ± 0.0068 (425 MeV); -0.4892 ± 0.0107 (492 MeV). These values have a noticeable effect on present day phase shift solutions. The magnitude of the ε 1 mixing parameter is reduced and other phase shifts are smoother around 300 MeV. (Author) (17 refs., 2 tabs., 3 figs.)

  1. Design, fabrication, and calibration of curved integral coils for measuring transfer function, uniformity, and effective length of LBL ALS [Lawrence Berkeley Laboratory Advanced Light Source] Booster Dipole Magnets

    International Nuclear Information System (INIS)

    Green, M.I.; Nelson, D.; Marks, S.; Gee, B.; Wong, W.; Meneghetti, J.

    1989-03-01

    A matched pair of curved integral coils has been designed, fabricated and calibrated at Lawrence Berkeley Laboratory for measuring Advanced Light Source (ALS) Booster Dipole Magnets. Distinctive fabrication and calibration techniques are described. The use of multifilar magnet wire in fabrication integral search coils is described. Procedures used and results of AC and DC measurements of transfer function, effective length and uniformity of the prototype booster dipole magnet are presented in companion papers. 8 refs

  2. Experimental analysis of heat transfer between a heated wire and a rarefied gas in an annular gap with high diameter ratio

    International Nuclear Information System (INIS)

    Chalabi, H; Lorenzini, M; Morini, G L; Buchina, O; Valougeorgis, D; Saraceno, L

    2012-01-01

    In this paper a first experimental attempt is performed to measure heat conduction through rarefied air at rest contained between two concentric cylinders. The heat transfer between a heated platinum wire having a diameter (d) of 0.15 mm, disposed along the axis of a cylindrical shell in stainless steel having an inner diameter (D) of 100 mm, and a surrounded rarefied gas has been studied experimentally and numerically. The ratio between the outer and inner diameter of the annular region filled by the gas is large (D/d=667). In the annular region filled with air the pressure was varied by using a vacuum pump from atmospheric value down to 10 −3 mbar. Temperature differences between the wire and the external stainless steel wall in the range 50-125 K were imposed and the heat power transferred from the wire to the surround was measured as a function of the gas pressure starting from air at atmospheric conditions down to 10 −3 mbar. The experimental results obtained in these tests were compared with the numerical results obtained by using the linear and nonlinear Shakhov kinetic models.

  3. Numerical analysis of the shifting slabs applied in a wireless power transfer system to enhance magnetic coupling

    Directory of Open Access Journals (Sweden)

    Yayun Dong

    2017-05-01

    Full Text Available Shifting medium is a kind of metamaterial, which can optically shift a space or an object a certain distance away from its original position. Based on the shifting medium, we propose a concise pair of shifting slabs covering the transmitting or receiving coil in a two-coil wireless power transfer system to decrease the equivalent distance between the coils. The electromagnetic parameters of the shifting slabs are calculated by transformation optics. Numerical simulations validate that the shifting slabs can approximately shift the electromagnetic fields generated by the covered coil; thus, the magnetic coupling and the efficiency of the system are enhanced while remaining the physical transmission distance unchanged. We also verify the advantages of the shifting slabs over the magnetic superlens. Finally, we provide two methods to fabricate shifting slabs based on split-ring resonators.

  4. Numerical analysis of the shifting slabs applied in a wireless power transfer system to enhance magnetic coupling

    Science.gov (United States)

    Dong, Yayun; Yang, Xijun; Jin, Nan; Li, Wenwen; Yao, Chen; Tang, Houjun

    2017-05-01

    Shifting medium is a kind of metamaterial, which can optically shift a space or an object a certain distance away from its original position. Based on the shifting medium, we propose a concise pair of shifting slabs covering the transmitting or receiving coil in a two-coil wireless power transfer system to decrease the equivalent distance between the coils. The electromagnetic parameters of the shifting slabs are calculated by transformation optics. Numerical simulations validate that the shifting slabs can approximately shift the electromagnetic fields generated by the covered coil; thus, the magnetic coupling and the efficiency of the system are enhanced while remaining the physical transmission distance unchanged. We also verify the advantages of the shifting slabs over the magnetic superlens. Finally, we provide two methods to fabricate shifting slabs based on split-ring resonators.

  5. Analysis and optimization of coupled windings in magnetic resonant wireless power transfer systems with orthogonal experiment method

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual...... inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and inductance for PCB windings at high- frequency. The method can reduce the design iterations and thereby can get...... more optimal design results. The experiments verified the design objective of kQ as well as the design method effectively. In the optimal PCB windings prototype at operating frequency of 4 MHz, the kQ and the maximum efficiency are increased by about 12% and 4% respectively....

  6. Analysis and optimisation of coupled winding in magnetic resonant wireless power transfer systems with orthogonal experiment results

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual...... inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and inductance for PCB windings at high- frequency. The method can reduce the design iterations and thereby can get...... more optimal design results. The experiments verified the design objective of kQ as well as the design method effectively. In the optimal PCB windings prototype at operating frequency of 4 MHz, the kQ and the maximum efficiency are increased by about 12% and 4% respectively....

  7. Thermal conductance of heat transfer interfaces for conductively cooled superconducting magnets

    International Nuclear Information System (INIS)

    Cooper, T.L.; Walters, J.D.; Fikse, T.H.

    1996-01-01

    Minimizing thermal resistances across interfaces is critical for efficient thermal performance of conductively cooled superconducting magnet systems. Thermal conductance measurements have been made for a flexible thermal coupling, designed to accommodate magnet-to-cryocooler and cryocooler-to-shield relative motion, and an interface incorporating Multilam designed as a sliding thermal connector for cryocoolers. Temperature changes were measured across each interface as a function of heat input. Thermal conductances have been calculated for each interface, and the impact of each interface on conductively cooled magnet systems will be discussed

  8. Momentum transfer resolved memory in a magnetic system with perpendicular anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Seu, Keoki; Roy, Sujoy; Su, Run; Parks, Daniel; Shipton, Erik; Fullerton, Eric; Kevan, Stephen

    2011-01-28

    We have used resonant, coherent soft x-ray scattering to measure wave vector re- solved magnetic domain memory in Co/Pd multilayers. The technique uses angular cross correlation functions and can be applied to any system with circular annuli of constant values of scattering wave vector q. In our Co/Pd film, the memory exhibits a maximum at q = 0.0384 nm-1 near initial reversal that decreases in magnitude as the magnetization is further reversed. The peak is attributed to bubble domains that nucleate reproducibly near initial reversal and which grow into a labyrinth domain structure that is not reproduced from one magnetization cycle to the next.

  9. Nuclear magnetic resonance study of charge transfer complex formation between Silver Nitrate and Benzylcyanide in Solvent Ethylene Glycol

    International Nuclear Information System (INIS)

    Modarress, H.; Shekaari, H.

    2003-01-01

    The formation constant for charge transfer complexes between electron acceptor (AgNo 3 ) and electron donor benzylcyanide (C 6 H 5 -CH 2 -C≡N) in solvent ethyleneglycol [(CH 2 OH) 2 ] has been evaluated by using the nuclear magnetic resonance chemical shifts of aromatic group of benzylcyanide measured against external references, tetramethylsilane, hexamethyldisilane and cyclohexane at 20 d ig C . The external referencing procedure eliminated the interference of internal reference in the course of complexation. The necessary bulk magnetic susceptibility corrections on the measured chemical shifts have been made. The solution nationalised and their effects on the formation constant have been considered and a new equation has been suggested to obtain the main ionic activity coefficient of AgNO 3 from nuclear magnetic resonance results. The mean ionic activity coefficient has been taken into account in the formation constant calculations. The results indicated that the appropriate formation constant should be expressed in terms of activities. Also an equation have been derived to eliminate the undesirable effects on the nuclear magnetic resonance measured chemical shifts in calculating the constant. The selection of concentration domains and its effect on the calculated formation constant has been discussed and the new equation is modified to be independent of the concentration domains. In this equation the solution nationalised, by considering coefficients, have been taken in to account

  10. Opportunities for high aspect ratio micro-electro-magnetic-mechanical systems (HAR-MEMMS) at Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    Hunter, S.

    1993-10-01

    This report contains viewgraphs on the following topics: Opportunities for HAR-MEMMS at LBL; Industrial Needs and Opportunities; Deep Etch X-ray Lithography; MEMS Activities at BSAC; DNA Amplification with Microfabricated Reaction Chamber; Electrochemistry Research at LBL; MEMS Activities at LLNL; Space Microsensors and Microinstruments; The Advanced Light Source; Institute for Micromaching; IBM MEMS Interests; and Technology Transfer Opportunities at LBL

  11. Synthesis of multi-wavelength temporal phase-shifting algorithms optimized for high signal-to-noise ratio and high detuning robustness using the frequency transfer function.

    Science.gov (United States)

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-05-02

    Synthesis of single-wavelength temporal phase-shifting algorithms (PSA) for interferometry is well-known and firmly based on the frequency transfer function (FTF) paradigm. Here we extend the single-wavelength FTF-theory to dual and multi-wavelength PSA-synthesis when several simultaneous laser-colors are present. The FTF-based synthesis for dual-wavelength (DW) PSA is optimized for high signal-to-noise ratio and minimum number of temporal phase-shifted interferograms. The DW-PSA synthesis herein presented may be used for interferometric contouring of discontinuous industrial objects. Also DW-PSA may be useful for DW shop-testing of deep free-form aspheres. As shown here, using the FTF-based synthesis one may easily find explicit DW-PSA formulae optimized for high signal-to-noise and high detuning robustness. To this date, no general synthesis and analysis for temporal DW-PSAs has been given; only ad hoc DW-PSAs formulas have been reported. Consequently, no explicit formulae for their spectra, their signal-to-noise, their detuning and harmonic robustness has been given. Here for the first time a fully general procedure for designing DW-PSAs (or triple-wavelengths PSAs) with desire spectrum, signal-to-noise ratio and detuning robustness is given. We finally generalize DW-PSA to higher number of wavelength temporal PSAs.

  12. Measurement of the magnetic neutron form factor at a four-momentum transfer of Q2 = 0.255 (GeV/c)2

    International Nuclear Information System (INIS)

    Reike, H.

    1993-12-01

    The Electron Stretcher Accelerator ELSA of Bonn University delivers an external electron beam with a duty factor of up to 55%. Thus nonmagnetic detectors can be used to perform electron nucleon coincidence experiments with high precision. The magnetic form factor of the neutron G m n is determined by the so-called ratio method, i.e. G m n is extracted from the measured ratio of the cross sections of the d(e,e'n) and d(e,e'p) reactions in a region of quasi-free kinematics. Protons and neutrons are detected simultaneously in the same scintillation counter, so many systematic errors cancel out. The neutron detection efficiency is measured in situ by the associated particle method using the p(γ,π + n) reaction. For this reaction the high energy part of the photons produced by the electron beam in the target is used. The value of G m n found at a four momentum transfer of Q 2 = 0.255 (GeV/c) 2 is (10.1 ± 3.8)% higher than the dipole value. (orig.)

  13. Results on heat transfer to He II for use in superconducting magnet technology

    International Nuclear Information System (INIS)

    Seyfert, P.

    1982-05-01

    The paper reviews several aspects of heat transfer to He II which are of practical interest for the cooling problem of superconductors. The heat transfer characteristics in the Kapitza boundary conductance regime are discussed and typical values for technical copper are given. It is shown how the peak heat flux depends on the boundary conditions of the bulk fluid and particularly on the time behaviour of heat sources. Results on transient recovery from film boiling applicable to superconductors are also presented

  14. Evaluating the accuracy of uranium isotope amount ratio measurements performed by a quadrupole and a multi-collector magnetic sector inductively coupled plasma mass spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Pereira de Oliveira, O. Jr.; Sarkis, J.E.S.; Ponzevera, E.; Alonso, A.; De Bolle, W.; Quetel, C.

    2008-01-01

    The n(U 235 )/n(U 238 ) isotope amount ratio in a set of samples was measured using two modern analytical techniques: quadrupole inductively coupled plasma mass spectrometry (ICP-QMS) and multi-collector magnetic sector inductively coupled plasma mass spectrometry (MC-ICPMS). The measured ratios were compared to the certified ratios provided by the high accuracy gas source mass spectrometry (GSMS). The components of the uncertainty were identified and their contribution to the combined standard uncertainty was estimated using the recommendations of the ISO-GUM guide. The values of the measurement uncertainty and bias were determined and then compared to the International Target Values for Measurement Uncertainties in Safeguarding Nuclear Materials. It appears that only the measurements performed by MC-ICPMS can meet the stringent requirements of international nuclear safeguards. (authors)

  15. Intensity ratio curve analysis of small renal masses on T2-weighted magnetic resonance imaging: Differentiation of fat-poor angiomyolipoma from renal cell carcinoma.

    Science.gov (United States)

    Moriyama, Shingo; Yoshida, Soichiro; Tanaka, Hajime; Tanaka, Hiroshi; Yokoyama, Minato; Ishioka, Junichiro; Matsuoka, Yoh; Saito, Kazutaka; Kihara, Kazunori; Fujii, Yasuhisa

    2018-03-25

    To assess the diagnostic ability of a pixel intensity-based analysis in evaluating the magnetic resonance imaging characteristics of small renal masses, especially in differentiating fat-poor angiomyolipoma from renal cell carcinoma. T2-weighted images from 121 solid small renal masses (ratio curve was plotted using intensity ratios, which were ratios of signal intensities of tumor pixels (each pixel along a linear region of interest drawn across the renal tumor on T2-weighted image) to the signal intensity of a normal renal cortex. The diagnostic ability of the intensity ratio curve analysis was evaluated. The tumors were classified into three types: intensity ratio fat-poor angiomyolipoma (n = 19) with no pseudocapsule, iso-low intensity and no heterogeneity; intensity ratio clear cell renal cell carcinoma (n = 76) with a pseudocapsule, iso-high intensity and heterogeneity; and other type of intensity ratio (n = 26), including tumors that did not fall into the above two categories. The sensitivity/specificity/accuracy of the intensity ratio curve analysis in diagnosing fat-poor angiomyolipoma was 93%/94%/94%, respectively. When the intensity ratio curve analysis was applied only to the tumor with undetermined radiological diagnosis, the sensitivity for diagnosing fat-poor angiomyolipoma compared with subjective reading alone significantly improved (93% vs 50%; P = 0.014). Our novel semiquantitative model for combined assessment of key features of fat-poor angiomyolipoma, including low intensity, homogeneity and absence of a pseudocapsule on T2-weighted image, might make diagnosis of fat-poor angiomyolipoma more accurate. © 2018 The Japanese Urological Association.

  16. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO{sub 3} nanowires with high length–diameter ratio

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui, E-mail: liuhui@sust.edu.cn; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-08-01

    WO{sub 3} nanowires (WO{sub 3}NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO{sub 3}NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO{sub 3}NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO{sub 3} nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO{sub 3} nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO{sub 3}NWs with high length–diameter ratio have been synthesized. • The WO{sub 3}NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite.

  17. Numerical Investigation of Fluid Flow and Heat Transfer Inside a 2D Enclosure with Three Hot Obstacles on the Ramp under the Influence of a Magnetic Field

    Directory of Open Access Journals (Sweden)

    M. M. Keshtkar

    2017-06-01

    Full Text Available This paper focuses on solving the fluid flow and heat transfer equations inside a two-dimensional square enclosure containing three hot obstacles affected by gravity and magnetic force placed on a ramp using Boltzmann method (LBM applying multiple relaxation times (MRT. Although, the Lattice Boltzmann with MRT is a complex technique, it is a relatively new, stable, fast and high-accurate one. The main objective of this research was to numerically model the fluid flow and ultimately obtaining the velocity field, flow and temperature contour lines inside a two-dimensional enclosure. The results and their comparisons for different types of heat transfer revealed that free or forced heat transfer has a considerable impact on the heat transfer and stream lines. This can be controlled by modifying the Richardson number. It is revealed that changing the intensity of the magnetic field (Hartman number has an appreciable effect on the heat transfer.

  18. Heat transfer to liquid sodium in a straight duct in the presence of a transverse magnetic field and a gravity field

    International Nuclear Information System (INIS)

    Majid, A.

    1998-01-01

    Heat transfer to liquid sodium in the presence of a transverse magnetic field and gravity field was analyzed in a square cross section straight duct. The duct had conducting vanadium walls. Magnetohydrodynamic equations in three dimensions and energy equation in three dimensions in cartesian coordinate system were solved. Firstly Nusselt number was calculated with no magnetic field and gravity field. Secondly the Nusselt number was calculated for the case of transverse magnetic field acting on the fluid. Thirdly Nusselt number was calculated for the case of transverse magnetic field and gravity field acting on the fluid. Only one face of the channel was heated. It was found that Nusselt number is not sensitive to application of gravity field and is slightly sensitive to application of transverse magnetic field. The sensitivity of Nusselt number to magnetic field intensity becomes almost negligible after increasing the strength of magnetic field to 0.1 Tesla. (author)

  19. PSI-ECRIT(S) a hybrid magnetic system with a mirror ratio of 10 for H-like heavy ion production and trapping

    CERN Document Server

    Biri, S; Hitz, D

    1999-01-01

    At the Paul Scherrer Institut ( PSI, Switzerland) an experimental program is started to measure the ground state shift and width of pionic hydrogen. To calibrate the crystal spectrometer X-ray transitions in hydrogen-like heavy ions (e.g. Ar17+) produced by ECR ion sources, are necessary. In PSI a superconducting cyclotron trap magnet originally developed for high energy experiments will be transformed into an ECR Ion Trap (ECRIT). The SC-magnet can deliver more than 4 Tesla magnetic fields with a mirror ratio of 2. A careful calculation showed this mirror ratio can be increased upto 10 and the trap can operate with frequencies between 5 and 20 GHz. To form a closed resonance zone a relatively large open structure (LBL-AECRU-type) NdFeB hexapole will be applied. The first tests will be performed with 6.4 GHz. Later higher frequencies (10 or 14.5 GHz) and the 2-frequency heating (6.4+10, 6.4+14.5 or 10+14.5) are planned to be applied to get enough quantity of H-like heavy ions. Since the main goal of this mach...

  20. Phosphorus-31 NMR magnetization transfer measurements of metabolic reaction rates in the rat heart and kidney in vivo

    International Nuclear Information System (INIS)

    Koretsky, A.P.

    1984-01-01

    31 P NMR is a unique tool to study bioenergetics in living cells. The application of magnetization transfer techniques to the measurement of steady-state enzyme reaction rates provides a new approach to understanding the regulation of high energy phosphate metabolism. This dissertation is concerned with the measurement of the rates of ATP synthesis in the rat kidney and of the creatine kinase catalyzed reaction in the rat heart in situ. The theoretical considerations of applying magnetization transfer techniques to intact organs are discussed with emphasis on the problems associated with multiple exchange reactions and compartmentation of reactants. Experimental measurements of the ATP synthesis rate were compared to whole kidney oxygen consumption and Na + reabsorption rates to derive ATP/O values. The problems associated with ATP synthesis rate measurements in kidney, e.g. the heterogeneity of the inorganic phosphate resonance, are discussed and experiments to overcome these problems proposed. In heart, the forward rate through creatine kinase was measured to be larger than the reverse rate. To account for the difference in forward and reverse rates a model is proposed based on the compartmentation of a small pool of ATP

  1. On the Origin of Sub-subgiant Stars. II. Binary Mass Transfer, Envelope Stripping, and Magnetic Activity

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Emily; Mathieu, Robert D. [Department of Astronomy, University of Wisconsin-Madison, 475 North Charter Street, Madison, WI 53706 (United States); Geller, Aaron M., E-mail: leiner@astro.wisc.edu [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA) and Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States)

    2017-05-10

    Sub-subgiant stars (SSGs) lie to the red of the main sequence and fainter than the red giant branch in cluster color–magnitude diagrams (CMDs), a region not easily populated by standard stellar evolution pathways. While there has been speculation on what mechanisms may create these unusual stars, no well-developed theory exists to explain their origins. Here we discuss three hypotheses of SSG formation: (1) mass transfer in a binary system, (2) stripping of a subgiant’s envelope, perhaps during a dynamical encounter, and (3) reduced luminosity due to magnetic fields that lower convective efficiency and produce large starspots. Using the stellar evolution code MESA, we develop evolutionary tracks for each of these hypotheses, and compare the expected stellar and orbital properties of these models with six known SSGs in the two open clusters M67 and NGC 6791. All three of these mechanisms can create stars or binary systems in the SSG CMD domain. We also calculate the frequency with which each of these mechanisms may create SSG systems, and find that the magnetic field hypothesis is expected to create SSGs with the highest frequency in open clusters. Mass transfer and envelope stripping have lower expected formation frequencies, but may nevertheless create occasional SSGs in open clusters. They may also be important mechanisms to create SSGs in higher mass globular clusters.

  2. Solar wind energy transfer to the earth magnetosphere due to the magnetic junction in the magnetopause

    International Nuclear Information System (INIS)

    Gonzalez, A.L.C. de; Gonzalez-Alarcon, W.D.; Jardim, M.V.A.

    1983-01-01

    An expression for the energy transfer due to magnetopause reconnection, as well as related expressions for the convection and parallel electric fields, are presented. These expressions are derived from a reconnection model centered at the magnetopause nose, and that considers the presence of the clefts. The expression for the convection - electric field - related energy transfer reduces to the substorm parameter epsilon for the special case of equal magnetosheath and geomagnetic field amplitudes. This result suggests that the reconnection electric field is transmitted along a tilted reconnection line, but that the convection field is only related to the 'dawn to dusk' component of the reconnection - electric field. (Author) [pt

  3. HVDC interrupter experiments for large Magnetic Energy Transfer and Storage (METS) systems

    International Nuclear Information System (INIS)

    Swannack, C.E.; Haarman, R.A.; Lindsay, J.D.G.; Weldon, D.M.

    1975-01-01

    Proposed fusion-test reactors will require energy storage systems of hundreds of megajoules with transfer times of the order of one millisecond. The size of the energy storage submodule (and hence, the overall system cost and complexity) is directly determined by the voltage and current limits of the switch used for the energy transfer. Experiments are being conducted on high voltage dc circuit breakers as a major part of the energy storage, pulsed power program. DC circuit interruption characteristics of a commercially available ac power vacuum interrupter are discussed. Preliminary data of interruption characteristics are reported for an interrupter developed specifically to match a present METS circuit requirement

  4. Features of the mass transfer in magnetic cataclysmic variables with fast-rotating white dwarfs

    Directory of Open Access Journals (Sweden)

    Isakova Polina

    2014-01-01

    Full Text Available The flow structure in magnetic cataclysmic variables was investigated taking into account the effects of strong magnetic field and fast rotation of the white dwarf. We modeled the AE Aqr system as a unique object that has the rotation period of the white dwarf is about 1000 times shorter than the orbital period of the binary system. Observations show that in spite of fast rotation of the white dwarf some part of the stream from the inner Lagrange point comes into the Roche lobe region. We analyzed possible mechanisms preventing material to outflow from the system.

  5. Spontaneous transfer of magnetically stored energy to Kinetic energy by electric double layers

    International Nuclear Information System (INIS)

    Lindberg, L.; Torven, S.

    1983-05-01

    Current disruptions are investigated in a magnetized plasma column with an inductive external electric circuit. It is found that they persist in spite of the fact that each disruption gives rise to a large inductive over-voltage. This drops off at an electric double layer formed in the plasma where most of the magnetic energy, initially stored in the circuit inductance, is released as particle energy. Simultanously as the current disrupts, the potential level at a local potential minimum in the plasma decreases. This is expected to cause the disruption by reflection of electrons. (authors)

  6. Multiscale modeling of current-induced switching in magnetic tunnel junctions using ab initio spin-transfer torques

    Science.gov (United States)

    Ellis, Matthew O. A.; Stamenova, Maria; Sanvito, Stefano

    2017-12-01

    There exists a significant challenge in developing efficient magnetic tunnel junctions with low write currents for nonvolatile memory devices. With the aim of analyzing potential materials for efficient current-operated magnetic junctions, we have developed a multi-scale methodology combining ab initio calculations of spin-transfer torque with large-scale time-dependent simulations using atomistic spin dynamics. In this work we introduce our multiscale approach, including a discussion on a number of possible schemes for mapping the ab initio spin torques into the spin dynamics. We demonstrate this methodology on a prototype Co/MgO/Co/Cu tunnel junction showing that the spin torques are primarily acting at the interface between the Co free layer and MgO. Using spin dynamics we then calculate the reversal switching times for the free layer and the critical voltages and currents required for such switching. Our work provides an efficient, accurate, and versatile framework for designing novel current-operated magnetic devices, where all the materials details are taken into account.

  7. Bias-voltage dependence of perpendicular spin-transfer torque in asymmetric MgO-based magnetic tunnel junctions

    KAUST Repository

    Oh, Se Chung; Park, Seung Young; Manchon, Aurelien; Chshiev, Mairbek; Han, Jae Ho; Lee, Hyun Woo; Lee, Jang Eun; Nam, Kyung Tae; Jo, Younghun; Kong, Yo Chan; Dieny, Bernard; Lee, Kyung Jin

    2009-01-01

    Spin-transfer torque (STT) allows the electrical control of magnetic states in nanostructures. The STT in magnetic tunnel junctions (MTJs) is of particular importance owing to its potential for device applications. It has been demonstrated that the MTJ has a sizable perpendicular STT (, field-like torque), which substantially affects STT-driven magnetization dynamics. In contrast to symmetric MTJs where the bias dependence of is quadratic, it is theoretically predicted that the symmetry breaking of the system causes an extra linear bias dependence. Here, we report experimental results that are consistent with the predicted linear bias dependence in asymmetric MTJs. The linear contribution is quite significant and its sign changes from positive to negative as the asymmetry is modified. This result opens a way to design the bias dependence of the field-like term, which is useful for device applications by allowing, in particular, the suppression of the abnormal switching-back phenomena. © 2009 Macmillan Publishers Limited. All rights reserved.

  8. Bias-voltage dependence of perpendicular spin-transfer torque in asymmetric MgO-based magnetic tunnel junctions

    KAUST Repository

    Oh, Se Chung

    2009-10-25

    Spin-transfer torque (STT) allows the electrical control of magnetic states in nanostructures. The STT in magnetic tunnel junctions (MTJs) is of particular importance owing to its potential for device applications. It has been demonstrated that the MTJ has a sizable perpendicular STT (, field-like torque), which substantially affects STT-driven magnetization dynamics. In contrast to symmetric MTJs where the bias dependence of is quadratic, it is theoretically predicted that the symmetry breaking of the system causes an extra linear bias dependence. Here, we report experimental results that are consistent with the predicted linear bias dependence in asymmetric MTJs. The linear contribution is quite significant and its sign changes from positive to negative as the asymmetry is modified. This result opens a way to design the bias dependence of the field-like term, which is useful for device applications by allowing, in particular, the suppression of the abnormal switching-back phenomena. © 2009 Macmillan Publishers Limited. All rights reserved.

  9. High levels of maternally transferred mercury disrupt magnetic responses of snapping turtle hatchlings (Chelydra serpentina).

    Science.gov (United States)

    Landler, Lukas; Painter, Michael S; Coe, Brittney Hopkins; Youmans, Paul W; Hopkins, William A; Phillips, John B

    2017-09-01

    The Earth's magnetic field is involved in spatial behaviours ranging from long-distance migration to non-goal directed behaviours, such as spontaneous magnetic alignment (SMA). Mercury is a harmful pollutant most often generated from anthropogenic sources that can bio-accumulate in animal tissue over a lifetime. We compared SMA of hatchling snapping turtles from mothers captured at reference (i.e., low mercury) and mercury contaminated sites. Reference turtles showed radio frequency-dependent SMA along the north-south axis, consistent with previous studies of SMA, while turtles with high levels of maternally inherited mercury failed to show consistent magnetic alignment. In contrast, there was no difference between reference and mercury exposed turtles on standard performance measures. The magnetic field plays an important role in animal orientation behaviour and may also help to integrate spatial information from a variety of sensory modalities. As a consequence, mercury may compromise the performance of turtles in a wide variety of spatial tasks. Future research is needed to determine the threshold for mercury effects on snapping turtles, whether mercury exposure compromises spatial behaviour of adult turtles, and whether mercury has a direct effect on the magnetoreception mechanism(s) that mediate SMA or a more general effect on the nervous system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Chirality Transfer in Magnetic Coordination Complexes Monitored by Vibrational and Electronic Circular Dichroism

    Czech Academy of Sciences Publication Activity Database

    Wu, T.; Zhang, X. P.; You, X. Z.; Li, Y. Z.; Bouř, Petr

    2014-01-01

    Roč. 79, č. 5 (2014), s. 698-707 ISSN 2192-6506 Institutional support: RVO:61388963 Keywords : chirality * circular dichroism * iron * magnetic properties * Schiff bases Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.997, year: 2014

  11. Analytical determination of 5th-order transfer matrices of magnetic quadrupole fringing fields

    International Nuclear Information System (INIS)

    Hartmann, B.; Irnich, H.; Wollnik, H.

    1993-01-01

    The fringing-field effects on particle trajectories in magnetic quadrupoles are described to 5th order by fringing-field integrals. It is shown that this method improves the description of fringing-field effects noticeably over the so far known use of third-order fringing-field integrals. (Author)

  12. Effects of Transferring to STEM-Focused Charter and Magnet Schools on Student Achievement

    Science.gov (United States)

    Judson, Eugene

    2014-01-01

    There have been strong calls to action in recent years to promote both school choice and the learning of science, technology, engineering, and mathematics (STEM). This has led to the burgeoning development of STEM-focused schools. Nine STEM-focused charter and 2 STEM-focused magnet schools that serve elementary-aged students were examined to…

  13. Image tuning techniques for enhancing the performance of pure permanent magnet undulators with small gap/period ratios

    Energy Technology Data Exchange (ETDEWEB)

    Tatchyn, R. [Stanford Univ., CA (United States)

    1995-12-31

    The on-axis field of a small-gap undulator constricted out of pure permanent magnet (PM) blocks arranged in an alternating-dipole (i.e., 2 dipoles/period) array can be substantially varied by positioning monolithic permeable plates above and below the undulator jaws. This simple technique, which can be used to control the 1st harmonic energy in conventional synchrotron radiation (SR) or Free Electron Laser (FEL) applications requiring sub-octave tuning, can also be shown to suppress magnetic inhomogeneities that can contribute to the undulator`s on-axis field errors. If a standard 4 block/period Halbach undulator, composed of PM blocks with square cross sections, is rearranged into an alternating-dipole array with the same period, the peak field that can be generated with superimposed image plates can substantially exceed that of the pure-PM Halbach array. This design technique, which can be viewed as intermediate between the {open_quotes}pure-PM{close_quotes} and standard {open_quotes}hybrid/PM{close_quotes} configurations, provides a potentially cost-effective method of enhancing the performance of small-gap, pure-PM insertion devices. In this paper we report on the analysis and recent characterization of pure-PM undulator structures with superimposed image plates, and discuss possible applications to FEL research.

  14. On the effect of subphase pH and counterions on transfer ratios and dynamic contact angles during deposition of multiple Langmuir-Blodgett monolayers

    International Nuclear Information System (INIS)

    Diaz, M. Elena; Cerro, Ramon L.

    2005-01-01

    The effects of pH and counterions on the type of deposition of Langmuir-Blodgett (LB) arachidic acid films onto hydrophobic glass slides is revisited. Unusually large differences in contact angles and transfer ratios (TR) were observed for subphase containing 10 -4 M of zinc sulfate and 2.10 -4 M of cadmium chloride, respectively, for a wide range of pH. Variations in TR occur at the same pH for different subphase cations and at different pH for the same divalent cations. These large variations in dynamic contact angles and TR as a function of pH point to the crucial role of electrical double layer forces in LB deposition phenomena. Transitions from Y- to X-type deposition are reported for pH larger or smaller than the pK A of the fatty acid-subphase salt system. Experimental results are compared with data reported in literature showing Z- to Y-transitions at pH close to the pK A of docosanoic acid monolayers

  15. Dependency of Tunneling-Magnetoresistance Ratio on Nanoscale Spacer Thickness and Material for Double MgO Based Perpendicular-Magnetic-Tunneling-Junction

    Science.gov (United States)

    Lee, Du-Yeong; Hong, Song-Hwa; Lee, Seung-Eun; Park, Jea-Gun

    2016-12-01

    It was found that in double MgO based perpendicular magnetic tunneling junction spin-valves ex-situ annealed at 400 °C, the tunneling magnetoresistance ratio was extremely sensitive to the material and thickness of the nanoscale spacer: it peaked at a specific thickness (0.40~0.53 nm), and the TMR ratio for W spacers (~134%) was higher than that for Ta spacers (~98%). This dependency on the spacer material and thickness was associated with the (100) body-centered-cubic crystallinity of the MgO layers: the strain enhanced diffusion length in the MgO layers of W atoms (~1.40 nm) was much shorter than that of Ta atoms (~2.85 nm) and the shorter diffusion length led to the MgO layers having better (100) body-centered-cubic crystallinity.

  16. Thin Co/Ni-based bottom pinned spin-transfer torque magnetic random access memory stacks with high annealing tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Tomczak, Y., E-mail: Yoann.Tomczak@imec.be [IMEC Kapeldreef 75, B-3001 Leuven (Belgium); Department of Chemistry, KU Leuven (University of Leuven), Celestijnenlaan 200F, B-3001 Leuven (Belgium); Swerts, J.; Mertens, S.; Lin, T.; Couet, S.; Sankaran, K.; Pourtois, G.; Kim, W.; Souriau, L.; Van Elshocht, S.; Kar, G.; Furnemont, A. [IMEC Kapeldreef 75, B-3001 Leuven (Belgium); Liu, E. [Department of Chemistry, KU Leuven (University of Leuven), Celestijnenlaan 200F, B-3001 Leuven (Belgium)

    2016-01-25

    Spin-transfer torque magnetic random access memory (STT-MRAM) is considered as a replacement for next generation embedded and stand-alone memory applications. One of the main challenges in the STT-MRAM stack development is the compatibility of the stack with CMOS process flows in which thermal budgets up to 400 °C are applied. In this letter, we report on a perpendicularly magnetized MgO-based tunnel junction (p-MTJ) on a thin Co/Ni perpendicular synthetic antiferromagnetic layer with high annealing tolerance. Tunnel magneto resistance (TMR) loss after annealing occurs when the reference layer loses its perpendicular magnetic anisotropy due to reduction of the CoFeB/MgO interfacial anisotropy. A stable Co/Ni based p-MTJ stack with TMR values of 130% at resistance-area products of 9 Ω μm{sup 2} after 400 °C anneal is achieved via moment control of the Co/Ta/CoFeB reference layer. Thinning of the CoFeB polarizing layer down to 0.8 nm is the key enabler to achieve 400 °C compatibility with limited TMR loss. Thinning the Co below 0.6 nm leads to a loss of the antiferromagnetic interlayer exchange coupling strength through Ru. Insight into the thickness and moment engineering of the reference layer is displayed to obtain the best magnetic properties and high thermal stability for thin Co/Ni SAF-based STT-MRAM stacks.

  17. Reduction of magnetic emission by increasing secondary side capacitor for ferrite geometry based series-series topology for wireless power transfer to vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik; Ahn, Seungyoung

    2014-01-01

    Magnetic fields emitted by wireless power transfer to vehicles can potentially affect living organisms. As a result, minimizing the magnetic emissions without compromising with the power transferred is one of the most significant challenges in the success of this technology. Active and passive...... and secondary currents from the standard design. Therefore, a part of the secondary magnetic flux comes in phase opposition with the primary flux and the resultant field is reduced. Operation point is shifted with the new design from the maximum power transfer resonance point and hence the reflected resistance...... is reduced. In order to maintain the same power level, the primary current and voltage have to increased and decreased in the same proportion. Also, the primary capacitor needs to be increased for maintaining unity input power factor in the system. The above statements are provided first with help...

  18. A study on Relay Effect via Magnetic Resonant Coupling for Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Rashid N.A.

    2016-01-01

    Full Text Available Wireless power transfer (WPT transmits electrical energy from a power source to an electrical load wirelessly or without any conductors. The capability of WPT to transmit the energy is limited. Therefore, a relay was introduced to increase the distance of the WPT capabilities. The effect of the relay has been investigated to extend the energy transfer distance. The effect of relay was demonstrated by placing a relay coil between transmitter and receiver, relay biased to transmitter and placing two relay coils in the designed system. Experimental results are provided to prove the concept of the relay effect. The power transmission efficiency can be achieved up to 75% at 1 meter distance.

  19. Energy Deposition in Adjacent LHC Superconducting Magnets from Beam Loss at LHC Transfer Line Collimators

    CERN Document Server

    Beavan, S; Kain, V

    2006-01-01

    Injection intensities for the LHC are over an order of magnitude above the damage threshold. The collimation system in the two transfer lines is designed to dilute the beam sufficiently to avoid damage in case of accidental beam loss or mis-steered beam. To maximise the protection for the LHC most of the collimators are located in the last 300 m upstream of the injection point where the transfer lines approach the LHC machine. To study the issue of possible quenches following beam loss at the collimators part of the collimation section in one of the lines, TI 8, together with the adjacent part of the LHC has been modeled in FLUKA. The simulated energy deposition in the LHC for worst-case accidental losses and as well as for losses expected during a normal filling is presented.

  20. Lateral spin transfer torque induced magnetic switching at room temperature demonstrated by x-ray microscopy

    Science.gov (United States)

    Buhl, M.; Erbe, A.; Grebing, J.; Wintz, S.; Raabe, J.; Fassbender, J.

    2013-10-01

    Changing and detecting the orientation of nanomagnetic structures, which can be used for durable information storage, needs to be developed towards true nanoscale dimensions for keeping up the miniaturization speed of modern nanoelectronic components. Therefore, new concepts for controlling the state of nanomagnets are currently in the focus of research in the field of nanoelectronics. Here, we demonstrate reproducible switching of a purely metallic nanopillar placed on a lead that conducts a spin-polarized current at room temperature. Spin diffusion across the metal-metal (Cu to CoFe) interface between the pillar and the lead causes spin accumulation in the pillar, which may then be used to set the magnetic orientation of the pillar. In our experiments, the detection of the magnetic state of the nanopillar is performed by direct imaging via scanning transmission x-ray microscopy (STXM).

  1. Aqueous dispersion of monodisperse magnetic iron oxide nanocrystals through phase transfer

    International Nuclear Information System (INIS)

    Yu, William W; Chang, Emmanuel; Sayes, Christie M; Drezek, Rebekah; Colvin, Vicki L

    2006-01-01

    A facile method was developed for completely transferring high quality monodisperse iron oxide nanocrystals from organic solvents to water. The as-prepared aqueous dispersions of iron oxide nanocrystals were extremely stable and could be functionalized for bioconjugation with biomolecules. These iron oxide nanocrystals showed negligible cytotoxicity to human breast cancer cells (SK-BR-3) and human dermal fibroblast cells. This method is general and versatile for many organic solvent-synthesized nanoparticles, including fluorescent semiconductor nanocrystals

  2. Skyrmion-number dependence of spin-transfer torque on magnetic bubbles

    Czech Academy of Sciences Publication Activity Database

    Yamane, Y.; Sinova, Jairo

    2016-01-01

    Roč. 120, č. 23 (2016), 1-4, č. článku 233901. ISSN 0021-8979 R&D Projects: GA ČR GB14-37427G; GA MŠk(CZ) LM2011026 EU Projects: European Commission(XE) 610115 - SC2 Institutional support: RVO:68378271 Keywords : dynamics * motion Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.068, year: 2016

  3. Effects of heat and mass transfer on peristaltic flow of a Bingham fluid in the presence of inclined magnetic field and channel with different wave forms

    International Nuclear Information System (INIS)

    Akram, Safia; Nadeem, S.; Hussain, Anwar

    2014-01-01

    In the present analysis we discussed the influence of heat and mass transfer on the peristaltic flow of a Bingham in an inclined magnetic field and channel with different wave forms. The governing two dimensional equations of momentum, heat and mass transfer are simplified under the assumptions of long wavelength and low Reynolds number approximation. The exact solutions of momentum, heat and mass transfer are calculated. Finally, graphical behaviors of various physical parameters are also discussed through the graphical behavior of pressure rise, pressure gradient, temperature concentration and stream functions. - Highlights: • Combine effects of heat and mass transfer on peristaltic flow problem is discussed. • Effects of inclined magnetic field and channel on new fluid model are discussed. • Effects of different wave forms are also discussed in the present flow problem

  4. Comparison of (31)P saturation and inversion magnetization transfer in human liver and skeletal muscle using a clinical MR system and surface coils.

    Science.gov (United States)

    Buehler, Tania; Kreis, Roland; Boesch, Chris

    2015-02-01

    (31)P MRS magnetization transfer ((31)P-MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various (31)P-MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major (31)P-MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used (31)P-MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR-undetectable metabolite pools can transfer MT to NMR-visible pools during long saturation pulses, which is prevented with short pulses. (31)P-MT sequences were adapted for limited pulse length, for heteronuclear transmit-receive surface coils with inhomogeneous B1 , for the need for volume selection and for the inherently low signal-to-noise ratio (SNR) on a clinical 3-T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte-Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ± 0.022 s(-1) (ST) and 0.137 ± 0.042 s(-1) (IT), whereas the creatine kinase reaction yielded 0.459 ± 0.089 s(-1) (IT). In the liver, ATP synthesis resulted in k = 0.267 ± 0.106 s(-1) (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit-receive surface coils; however, ST results are

  5. Diagnostic usefulness of the oedema-infarct ratio to differentiate acute from chronic myocardial damage using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yamada, Kiyoyasu; Suzuki, Susumu; Kinoshita, Kousuke; Yokouchi, Kazuhiko; Iwata, Hirokazu; Sawada, Ken; Isobe, Satoshi; Ohshima, Satoru; Murohara, Toyoaki; Hirai, Makoto

    2012-01-01

    To differentiate acute from chronic damage to the myocardium in patients with myocardial infarction (MI) using DE and T2w MR. Short-axis T2w and DE MR images were acquired twice after the onset of MI in 36 patients who successfully underwent emergency coronary revascularisation. The areas of infarct and oedema were measured. The oedema-infarct ratio (O/I) of the left ventricular area was calculated by dividing the oedema by the infarct area. The oedema size on T2w MR was significantly larger than the infarct size on DE MR in the acute phase. Both the oedema size on T2w MR and the infarct size on DE MR in the acute phase were significantly larger than those in the chronic phase. The O/I was significantly greater in the acute phase compared with that in the chronic phase (P < 0.05). An analysis of relative cumulative frequency distributions revealed an O/I of 1.4 as a cut-off value for differentiating acute from chronic myocardial damage with the sensitivity, specificity, and accuracy of 85.1%, 82.7% and 83.9%, respectively. The oedema-infarct ratio may be a useful index in differentiating acute from chronic myocardial damage in patients with MI. (orig.)

  6. Effects of Anisotropic Thermal Conductivity and Lorentz Force on the Flow and Heat Transfer of a Ferro-Nanofluid in a Magnetic Field

    Directory of Open Access Journals (Sweden)

    Yubai Li

    2017-07-01

    Full Text Available In this paper, we study the effects of the Lorentz force and the induced anisotropic thermal conductivity due to a magnetic field on the flow and the heat transfer of a ferro-nanofluid. The ferro-nanofluid is modeled as a single-phase fluid, where the viscosity depends on the concentration of nanoparticles; the thermal conductivity shows anisotropy due to the presence of the nanoparticles and the external magnetic field. The anisotropic thermal conductivity tensor, which depends on the angle of the applied magnetic field, is suggested considering the principle of material frame indifference according to Continuum Mechanics. We study two benchmark problems: the heat conduction between two concentric cylinders as well as the unsteady flow and heat transfer in a rectangular channel with three heated inner cylinders. The governing equations are made dimensionless, and the flow and the heat transfer characteristics of the ferro-nanofluid with different angles of the magnetic field, Hartmann number, Reynolds number and nanoparticles concentration are investigated systematically. The results indicate that the temperature field is strongly influenced by the anisotropic behavior of the nanofluids. In addition, the magnetic field may enhance or deteriorate the heat transfer performance (i.e., the time-spatially averaged Nusselt number in the rectangular channel depending on the situations.

  7. Magnets

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    A magnet pole piece for an NMR imaging magnet is made of a plurality of magnetic wires with one end of each wire held in a non-magnetic spacer, the other ends of the wires being brought to a pinch, and connected to a magnetic core. The wires may be embedded in a synthetic resin and the magnetisation and uniformity thereof can be varied by adjusting the density of the wires at the spacer which forms the pole piece. (author)

  8. Perpendicular magnetic tunnel junction with tunneling magnetoresistance ratio of 64% using MgO (100) barrier layer prepared at room temperature

    International Nuclear Information System (INIS)

    Ohmori, Hideto; Hatori, Tomoya; Nakagawa, Shigeki

    2008-01-01

    MgO (100) textured films can be prepared by reactive facing targets sputtering at room temperature without postdeposition annealing process when they were deposited on (100) oriented Fe buffer layers. This method allows fabrication of perpendicular magnetic tunnel junction (p-MTJ) with MgO (100) tunneling barrier layer and rare-earth transition metal (RE-TM) alloy thin films as perpendicularly magnetized free and pinned layers. The 3-nm-thick MgO tunneling barrier layer in p-MTJ multilayer prepared on glass substrate revealed (100) crystalline orientation. Extraordinary Hall effect measurement clarified that the perpendicular magnetic components of 3-nm-thick Fe buffer layers on the two ends of MgO tunneling barrier layer were increased by exchange coupling with RE-TM alloy layers. The RA of 35 kΩ μm 2 and tunneling magnetoresistance ratio of 64% was observed in the multilayered p-MTJ element by current-in-plane-tunneling

  9. Effects of magnetic, radiation and chemical reaction on unsteady heat and mass transfer flow of an oscillating cylinder

    Science.gov (United States)

    Ahmed, Rubel; Rana, B. M. Jewel; Ahmmed, S. F.

    2017-06-01

    The effects of magnetic, radiation and chemical reaction parameters on the unsteady heat and mass transfer boundary layer flow past an oscillating cylinder is considered. The dimensionless momentum, energy and concentration equations are solved numerically by using explicit finite difference method with the help of a computer programming language Compaq visual FORTRAN 6.6a. The obtained results of this study have been discussed for different values of well-known parameters with different time steps. The effect of these parameters on the velocity field, temperature field and concentration field, skin-friction, Nusselt number, streamlines and isotherms has been studied and results are presented by graphically represented by the tabular form quantitatively. The stability and convergence analysis of the solution parameters that have been used in the mathematical model have been tested.

  10. Study of heat transfer and flow of nanofluid in permeable channel in the presence of magnetic field

    Directory of Open Access Journals (Sweden)

    M. Fakour

    2015-03-01

    Full Text Available In this paper, laminar fluid flow and heat transfer in channel with permeable walls in the presence of a transverse magnetic field is investigated. Least square method (LSM for computing approximate solutions of nonlinear differential equations governing the problem. We have tried to show reliability and performance of the present method compared with the numerical method (Runge-Kutta fourth-rate to solve this problem. The influence of the four dimensionless numbers: the Hartmann number, Reynolds number, Prandtl number and Eckert number on non-dimensional velocity and temperature profiles are considered. The results show analytical present method is very close to numerically method. In general, increasing the Reynolds and Hartman number is reduces the nanofluid flow velocity in the channel and the maximum amount of temperature increase and increasing the Prandtl and Eckert number will increase the maximum amount of theta.

  11. A Three-Component Model for Magnetization Transfer. Solution by Projection-Operator Technique, and Application to Cartilage

    Science.gov (United States)

    Adler, Ronald S.; Swanson, Scott D.; Yeung, Hong N.

    1996-01-01

    A projection-operator technique is applied to a general three-component model for magnetization transfer, extending our previous two-component model [R. S. Adler and H. N. Yeung,J. Magn. Reson. A104,321 (1993), and H. N. Yeung, R. S. Adler, and S. D. Swanson,J. Magn. Reson. A106,37 (1994)]. The PO technique provides an elegant means of deriving a simple, effective rate equation in which there is natural separation of relaxation and source terms and allows incorporation of Redfield-Provotorov theory without any additional assumptions or restrictive conditions. The PO technique is extended to incorporate more general, multicomponent models. The three-component model is used to fit experimental data from samples of human hyaline cartilage and fibrocartilage. The fits of the three-component model are compared to the fits of the two-component model.

  12. Quantification of the magnetization-transfer contrast effect: can it yield additional information in differentiation of musculoskeletal lesions particularly in separation of benign from malignant lesions; Quantifizierung des Magnetization Transfer Contrast (MTC) Effektes durch Berechnung von MT-Quotienten: Ergeben sich Zusatzinformationen fuer die Differenzierung benigner und maligner Erkrankungen des Bewegungsapparates?

    Energy Technology Data Exchange (ETDEWEB)

    Vahlensieck, M.; Traeber, F.; Schild, H. [Radiologische Universitaetsklinik Bonn (Germany); Gieseke, J. [Philips Medizinsysteme (Germany)

    1999-12-01

    Purpose: To investigate the potential information of the amount of magnetization-transfer effect in musculoskeletal lesions and to compare MT ratios from benign and malignant musculoskeletal lesions. Material and Method: 49 patients with malignant tumors (3 osteosarcoma, 3 malignant fibrous histiocytoma, 4 chondrosarcoma, 2 Ewing sarcomas) and benign lesions (8 chondroma, 2 fibrous dysplasia, 3 osteoid-osteoma, 6 ganglion cyst, 3 cyst, 3 osteomyelitis, 4 tendinitis, 3 rotator cuff tear, 5 scar tissue) were scanned using routine MRI protocols including T{sub 1}- and T{sub 2}-weighted spin echo as well as T{sub 2}*-weighted gradient echo (FFE) sequences at 1.5 Tesla (ACS II, Philips Medical). Additionally MTC images were generated by combining the FFE sequence and the off-resonance MT technique (-1500 Hz off-resonance frequency, 1770 flip angle and 50 ms pulse duration). MT ratios were calculated as SI{sub o}-SI{sub m}/SI{sub o}. Results: The MT ratio of benign lesions was 26{+-}15%, that of malignant lesions was 22{+-}6%. The difference was statistically not significant. As expected muscle showed a high MT ratio of 50{+-}8%. Scar tissue demonstrated an MT ratio of 39{+-}16% which was significantly higher than the tumor MT ratios. Conclusion: MTC (MT ratios) failed to show significant differences between benign and malignant lesions as was expected due to basic differences in cellularity, rate of mitosis and chromatin content. MTC might however gain more importance in separating scar tissue from recurrent tumor in the future. (orig.) [German] Zielsetzung: Durch die Quantifizierung des Magnetization Transfer Contrastes sollte untersucht werden, ob sich Zusatzinformationen in der Magnetresonanztomographie des Stuetz- und Bewegungsapparates ergeben. Insbesondere sollte ermittelt werden, ob gut- und boesartige Laesionen unterschiedliche MT-Quotienten aufweisen. Material und Methode: 49 Patienten mit boesartigen Tumoren (3 Osteosarkom, 4 Chondrosarkom, 3 Malignes

  13. Insights into Dynamic Tuning of Magnetic-Resonant Wireless Power Transfer Receivers Based on Switch-Mode Gyrators

    Directory of Open Access Journals (Sweden)

    Mohamed Saad

    2018-02-01

    Full Text Available Magnetic-resonant wireless power transfer (WPT has become a reliable contactless source of power for a wide range of applications. WPT spans different power levels ranging from low-power implantable devices up to high-power electric vehicles (EV battery charging. The transmission range and efficiency of WPT have been reasonably enhanced by resonating the transmitter and receiver coils at a common frequency. Nevertheless, matching between resonance in the transmitter and receiver is quite cumbersome, particularly in single-transmitter multi-receiver systems. The resonance frequency in transmitter and receiver tank circuits has to be perfectly matched, otherwise power transfer capability is greatly degraded. This paper discusses the mistuning effect of parallel-compensated receivers, and thereof a novel dynamic frequency tuning method and related circuit topology and control is proposed and characterized in the system application. The proposed method is based on the concept of switch-mode gyrator emulating variable lossless inductors oriented to enable self-tunability in WPT receivers.

  14. Magnetization transfer from macromolecules to water protons in murine dental tissues as revealed by 500 MHz 1H-NMR

    International Nuclear Information System (INIS)

    Nakamura, Koji; Era, Seiichi; Nagai, Naoki; Sogami, Masaru; Takasaki, Akihiko; Kato, Kazuo.

    1997-01-01

    Although much is known about magnetization transfer phenomena in biological soft tissues, little is known about those in hard tissues. Using a 500 MHz 1 H-NMR spectrometer, we studied the spin-lattice relaxation time (T 1 (H 2 O)) and the intermolecular cross-relaxation times (T IS (H 2 O)) from irradiated macromolecular protons to observed water protons in murine lower incisors (hard tissue) and compared with those in murine lens tissue (soft tissue). Mean values for the water content (%) of murine lower incisors and lens tissue were 16.02±2.39 (n=14) and 67.20±4.60 (n=15), respectively. These findings were consistent with the large different in water content between soft tissues and hard tissues. T IS (H 2 O) values obtained by f 2 -irradiation at 7.13 or -4.00 ppm showed no significant difference between lower incisors and lens tissue. Plots of 1/T IS (H 2 O) values vs. tissue dry weight (W(%)) for lower incisor tissue approximated a straight line with slope approximately equal for that obtained for lens tissue. These results suggest that the state of water in hard tissue may be similar to that in soft tissues, in spite of the significant difference in water content. Thus, saturation transfer NMR techniques such as measurement of T IS (H 2 O) values may be applicable to the study of water-macromolecule interactions in both biological soft and hard tissues. (author)

  15. Multiferroicity in an organic charge-transfer salt that is suggestive of electric-dipole-driven magnetism

    Science.gov (United States)

    Lunkenheimer, Peter; Müller, Jens; Krohns, Stephan; Schrettle, Florian; Loidl, Alois; Hartmann, Benedikt; Rommel, Robert; de Souza, Mariano; Hotta, Chisa; Schlueter, John A.; Lang, Michael

    2012-09-01

    Multiferroics, showing simultaneous ordering of electrical and magnetic degrees of freedom, are remarkable materials as seen from both the academic and technological points of view. A prominent mechanism of multiferroicity is the spin-driven ferroelectricity, often found in frustrated antiferromagnets with helical spin order. There, as for conventional ferroelectrics, the electrical dipoles arise from an off-centre displacement of ions. However, recently a different mechanism, namely purely electronic ferroelectricity, where charge order breaks inversion symmetry, has attracted considerable interest. Here we provide evidence for ferroelectricity, accompanied by antiferromagnetic spin order, in a two-dimensional organic charge-transfer salt, thus representing a new class of multiferroics. We propose a charge-order-driven mechanism leading to electronic ferroelectricity in this material. Quite unexpectedly for electronic ferroelectrics, dipolar and spin order arise nearly simultaneously. This can be ascribed to the loss of spin frustration induced by the ferroelectric ordering. Hence, here the spin order is driven by the ferroelectricity, in marked contrast to the spin-driven ferroelectricity in helical magnets.

  16. Combined Conformal Strongly-Coupled Magnetic Resonance for Efficient Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Matjaz Rozman

    2017-04-01

    Full Text Available This paper proposes a hybrid circuit between a conformal strongly-coupled magnetic resonance (CSCMR and a strongly-coupled magnetic resonance (SCMR, for better wireless power transmission (WPT. This combination promises to enhance the flexibility of the proposed four-loop WPT system. The maximum efficiency at various distances is achieved by combining coupling-matching between the source and transmitting coils along with the coupling factor between the transmitting and receiving coils. Furthermore, the distance between transmitting and receiving coils is investigated along with the distance relationship between the source loop and transmission coil, in order to achieve the maximum efficiency of the proposed hybrid WPT system. The results indicate that the proposed approach can be effectively employed at distances comparatively smaller than the maximum distance without frequency matching. The achievable efficiency can be as high as 84% for the whole working range of the transmitter. In addition, the proposed hybrid system allows more spatial freedom compared to existing chargers.

  17. Non-contact magnetic coupled power and data transferring system for an electric vehicle

    International Nuclear Information System (INIS)

    Matsuda, Y.; Sakamoto, H.

    2007-01-01

    We have developed a system which transmits electric power and communication data simultaneously in a non-contact method using a magnetic coupling coil. Already, we are developing the fundamental technology of a non-contact charging system, and this is applied in electric shavers, electric toothbrushes, etc. Moreover, basic experiments are being conducted for applying this non-contact charging system to electric equipments such as an electric vehicle (EV), which is a zero emission vehicle and environmentally excellent and will be the transportation means of the next generation. The technology can also be applied in other electronic equipment, etc. However, since the power supply route for these individual devices is independent, the supply system is complicated. EV also has to perform the transmission of electric power and the transmission of information (data), such as the amount of the charge, in a separate system, and thus is quite complicated. In this study, by performing simultaneously the transmission of electric power and information (data) using magnetic coupling technology in which it does not contact, the basic experiment aimed at attaining and making unification of a system simple was conducted, and the following good results were obtained: (1) Electric power required for load can be transmitted easily by non-contact. (2) A signal can easily be transmitted bidirectionally by non-contact. (3) This system is reliable, and is widely applicable

  18. Applicability and reliability of the 'observed ratio' model as a means of describing the strontium and the cesium transfer from soil to plant. Eignung und Zuverlaessigkeit des 'observed ratio' Modells fuer die Beschreibung des Strontium- und Caesium-Transfers vom Boden in die Pflanze

    Energy Technology Data Exchange (ETDEWEB)

    Leising, C.

    1986-12-01

    The report examines the suitability of the observed ratio, (OR), model as a means of describing the soil-to-plant transfer of cesium and strontium, and the reliability of results determined by this model. Literature studies have been made and are reported in order to show the discrimination between Sr and Ca, or Cs and K, respectively, and in order to show the magnitude of the OR value and the range of values it may cover. For the evaluation of results, care has been taken that only the physiologically relevant constituents of Sr, Ca, Cs, and K concentrations in the soil are taken into account, which are the water-soluble and the adsorptively bound forms. Non-mobile forms cannot be taken up by the plant and therefore are not considered in the model. In accordance with the literature reviewed, the report also differentiates between two experimental approaches: (1) hydroponics, and (2) greenhouse or field experiments.

  19. Numerical investigation of MHD heat transfer in a vertical round tube affected by transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Zikanov, Oleg [University of Michigan - Dearborn, MI 48128-1491 (United States); Listratov, Yaroslav [Moscow Power Engineering Institute, 14 Karsnokazarmennaya St., Moscow 111250 (Russian Federation)

    2016-12-15

    Numerical simulations of the flow of a liquid metal in a vertical pipe are performed. The configuration reproduces the test section of the recent experiment . The mean flow is directed downward, a half of the pipe's wall is heated, and a strong horizontal magnetic field perpendicular to the temperature gradient is imposed. The simulations produce results in good agreement with the experiment and lead us to an explanation of the observed phenomenon of anomalous high-amplitude temperature fluctuations. The fluctuations are caused by growth and quasi-periodic breakdown of the pairs of ascending and descending jets related to the elevator-mode thermal convection. Implications for operation of liquid metal blankets with poloidal ducts are discussed.

  20. Optimization of transfer of laser-cooled atom cloud to a quadrupole ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... We present here our experimental results on transfer of laser-cooled atom cloud to a quadrupole magnetic trap. We show that by choosing appropriately the ratio of potential energy in magnetic trap to kinetic energy of cloud in molasses, we can obtain the maximum phase-space density in the magnetic trap.

  1. Heat transfer and entropy generation analysis of hybrid graphene/Fe3O4 ferro-nanofluid flow under the influence of a magnetic field

    DEFF Research Database (Denmark)

    Mehrali, Mohammad; Sadeghinezhad, Emad; Akhiani, Amir Reza

    2017-01-01

    oxide, iron salts and tannic acid as the reductant and stabilizer. The thermophysical and magnetic properties of the hybrid nanofluid have been widely characterized and thermal conductivity has shown an enhancement of 11%. The experimental results indicated that the heat transfer enhancement of hybrid...

  2. Magnetic Emissions Reduction by Varying Secondary Side Capacitor for Ferrite Geometry based Series-Parallel Topology Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Magnetic fields in surroundings of wireless power transfer system depends upon the two coil currents, distance from the coils and space angle between the two coil fields in steady state conditions. Increase in value of the secondary capacitor leads to a phase shift between the two currents and as...

  3. Numerical investigation of the heat transfer of a ferrofluid inside a tube in the presence of a non-uniform magnetic field

    Science.gov (United States)

    Hariri, Saman; Mokhtari, Mojtaba; Gerdroodbary, M. Barzegar; Fallah, Keivan

    2017-02-01

    In this article, a three-dimensional numerical investigation is performed to study the effect of a magnetic field on a ferrofluid inside a tube. This study comprehensively analyzes the influence of a non-uniform magnetic field in the heat transfer of a tube while a ferrofluid (water with 0.86 vol% nanoparticles (Fe3O4) is let flow. The SIMPLEC algorithm is used for obtaining the flow and heat transfer inside the tube. The influence of various parameters, such as concentration of nanoparticles, intensity of the magnetic field, wire distance and Reynolds number, on the heat transfer is investigated. According to the obtained results, the presence of a non-uniform magnetic field significantly increases the Nusselt number (more than 300%) inside the tube. Also, the magnetic field induced by the parallel wire affects the average velocity of the ferrofluid and forms two strong eddies in the tube. Our findings show that the diffusion also raises as the concentration of the nanoparticle is increased.

  4. The relationship between cognitive impairment and in vivo metabolite ratios in patients with clinical Alzheimer's disease and vascular dementia: a proton magnetic resonance spectroscopy study

    International Nuclear Information System (INIS)

    Waldman, A.D.; Rai, G.S.

    2003-01-01

    Previous magnetic resonance spectroscopy (MRS) studies have shown increased myo-inositol (MI) and decreased N-acetyl aspartate (NAA) levels in the parieto-occipital lobes of patients with Alzheimer's disease (AD) compared to those with other dementias and normal subjects. This study aimed to establish the quantitative relationship between metabolite ratios and degree of cognitive impairment in patients with mild to moderate AD and sub-cortical ischaemic vascular dementia (SIVD). Forty-four older people with clinical dementia were recruited from a memory clinic and followed up for 2.0-3.5 years; 20 cases were finally classified as probable AD, 18 as SIVD and 6 as mixed type. Mini Mental State Examination (MMSE) and short echo time single voxel automated MRS from the mesial parieto-occipital lobes were performed at the time of initial referral. Spearman rank correlation coefficients were calculated for MMSE scores and measured metabolite ratios MI/Cr, NAA/Cr, Cho/Cr and NAA/MI. The AD group showed a significant correlation between MMSE and NAA/MI (r=0.54, P=0.014) and NAA/Cr (r=0.48, P=0.033), and a negative, non-significant association with MI/Cr (r=-0.41, P=0.072). MI/Cr was negatively correlated with NAA/Cr (r=-0.51, P=0.021). Neither Cho/Cr ratios nor age correlated with cognitive function. The SIVD group showed no correlation between any of the measured metabolite ratios and MMSE score. This study reinforces the specific association between reduced NAA and increased MI levels in the parieto-occipital region and cognitive impairment in AD. MRS may have a role in evaluating disease progression and therapeutic monitoring in AD, as new treatments become available. (orig.)

  5. Aligned Magnetic Field Effects on Flow and Heat Transfer of the Upper-Convected Maxwell Fluid over a Stretching/Shrinking Sheet

    Directory of Open Access Journals (Sweden)

    Waini Iskandar

    2017-01-01

    Full Text Available In this paper, the effect of aligned magnetic field towards the flow and heat transfer of the upper-convected Maxwell (UCM fluid over a stretching/shrinking sheet is numerically studied. The governing partial differential equations are reduced into a system of ordinary differential equations using a similarity transformation, which are then solved numerically using the shooting method. The skin friction and heat transfer coefficients, the velocity, as well as the temperature profiles of the fluid are presented and discussed. Results indicate that an increase in the aligned angle strengthens the applied magnetic field which decrease the velocity and increase the temperature profiles of the fluid. This implies that an increase in the aligned angle increases the skin friction coefficient and decreases the heat transfer coefficients.

  6. Cold-Fluid Equilibrium of a Large-Aspect-Ratio Ellipse-Shaped Charged-Particle Beam in a Non-Axisymmetric Periodic Permanent Magnet Focusing Field

    CERN Document Server

    Zhou, Jing; Chen Chi Ping

    2005-01-01

    A new class of equilibrium is discovered for a large-aspect-ratio ellipse-shaped charged-particle beam in a non-axisymmetric periodic permanent magnet focusing field. A paraxial cold-fluid model is employed to derive the equilibrium flow properties and generalized envelope equations with negligibly small emittance. A periodic beam equilibrium solution is obtained numerically from the generalized envelope equations. It is shown that the beam edges are well confined in both transverse directions, and that the equilibrium beam exhibits a small-angle periodic wobble as it propagates. A two-dimensional particle-in-cell (PIC) code, PFB2D, is used to verify the theoretical predictions in the paraxial limit, and to establish validity under non-paraxial situations and the influence of the conductor walls of the beam tunnel.

  7. Numerical simulation of flow and heat transfer of continous cast steel slab under traveling magnetic field

    Directory of Open Access Journals (Sweden)

    Gong Haijun

    2013-03-01

    Full Text Available A unified numerical model for simulating solidification transport phenomena (STP of steel slab in electromagnetic continuous casting (EMCC process was developed. In order to solve the multi-physics fields coupled problem conveniently, the complicated bidirectional coupled process between EM and STP was simplified as a unidirectional one, and a FEM/FVM-combined numerical simulation technique was adopted. The traveling magnetic fields (TMFs applied to the EMCC process were calculated using the ANSYS11.0 software, and then the EM-data output by ANSYS were converted to FVM-format using a data-format conversion program developed previously. Thereafter, the governing equations were solved using a pressure-based Direct-SIMPLE algorithm. The simulation results of the STP in CC-process show that, due to the influences of Lorentz force and Joule heat, the two strong circulating flows and the temperature field can be obviously damped and changed once TMF with one pair of poles (1-POPs or 2-POPs is applied, which would accordingly improve the quality of casting. It was found in the present research that the integrated actions of 2-POPs TMF are superior to 1-POPs. All the computations indicate that the present numerical model of EM-STP as well as the FEM/FVM-combined technique is successful.

  8. Signal-to-noise ratio, T2 , and T2* for hyperpolarized helium-3 MRI of the human lung at three magnetic field strengths.

    Science.gov (United States)

    Komlosi, Peter; Altes, Talissa A; Qing, Kun; Mooney, Karen E; Miller, G Wilson; Mata, Jaime F; de Lange, Eduard E; Tobias, William A; Cates, Gordon D; Mugler, John P

    2017-10-01

    To evaluate T 2 , T2*, and signal-to-noise ratio (SNR) for hyperpolarized helium-3 ( 3 He) MRI of the human lung at three magnetic field strengths ranging from 0.43T to 1.5T. Sixteen healthy volunteers were imaged using a commercial whole body scanner at 0.43T, 0.79T, and 1.5T. Whole-lung T 2 values were calculated from a Carr-Purcell-Meiboom-Gill spin-echo-train acquisition. T2* maps and SNR were determined from dual-echo and single-echo gradient-echo images, respectively. Mean whole-lung SNR values were normalized by ventilated lung volume and administered 3 He dose. As expected, T 2 and T2* values demonstrated a significant inverse relationship to field strength. Hyperpolarized 3 He images acquired at all three field strengths had comparable SNR values and thus appeared visually very similar. Nonetheless, the relatively small SNR differences among field strengths were statistically significant. Hyperpolarized 3 He images of the human lung with similar image quality were obtained at three field strengths ranging from 0.43T and 1.5T. The decrease in susceptibility effects at lower fields that are reflected in longer T 2 and T2* values may be advantageous for optimizing pulse sequences inherently sensitive to such effects. The three-fold increase in T2* at lower field strength would allow lower receiver bandwidths, providing a concomitant decrease in noise and relative increase in SNR. Magn Reson Med 78:1458-1463, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. The Effect of Ca–Zr mole ratio on preparation, structural and magnetic properties of Ca–Zr doped Bi-YIG

    International Nuclear Information System (INIS)

    Hasanpour, A.; Niyaifar, M.; Faridniya, N.; Amighian, J.

    2013-01-01

    Graphical abstract: - Highlights: • Ca–Zr substituted Bi-YIG has been prepared via mechanochemical processing and heat treatment. • Structural and magnetic properties were investigated. • Magnetic measurements showed the Ferrimagnetic behavior for pure garnet structure samples. • The spherical morphology of the nanoparticles was found from the SEM micrograph. - Abstract: Ca–Zr substituted (Bi-YIG) nanopowders with a nominal composition of BiY 2−x Ca x Zr y Fe 5−y O 12 (x = y and x varied from 0.00 to 1.25 by the step of 0.25) were prepared by mechanochemical processing (MCP) and subsequent heat treatments. The effect of dopant mol ratios, on garnet phase formation were investigated by X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy. The lattice constant of the samples increased by increasing Zr 4+ content (for x ≤ 1). Mean crystallite size of the single-phase powders, which was evaluated by Scherrer's formula, was about 35 nm. The experimental results show that the Ca–Zr substitution Bi-YIG lowers the calcining and sintering temperatures for x < 1. The results show that the single-phase nanopowders can be obtained at temperatures below 850 °C. The measurements of vibrating sample magnetometer (VSM) show that the saturation magnetization of the samples increases as x increase from 0.00 to 0.25 and then decreases by increasing x to the values greater than 0.25

  10. Tracing transfer processes of metal pollutants from soils to surface water using environmental magnetic techniques - results from Paris suburbia (France)

    Science.gov (United States)

    Franke, Christine; Lamy, Isabelle; van Oort, Folkert; Thiesson, Julien; Barsalini, Luca

    2015-04-01

    acidification (forestation, lixiviation by rain water, etc). Such anthropogenic metal phases were found in the suspended particular matter of the Seine river system, but the transfer mechanisms and pathways from the polluted soils to the surface waters are not yet fully understood and lack high resolution quantitative methods. In this work we aime at calibrating the environmental magnetic measurements that are tested as complementary tracer tools in combination with more classical geochemical analyses. We performed a magnetic cartography using susceptibility along a topographic profile from the different types of polluted soils (agricultural soil, forest deposits, waste land, flooding plains, etc) towards the surface waters (sediment traps of suspended particular matter) draining this area. The results were compared with laboratory susceptibility and elementary composition (XRF) analyses on the freeze dried bulk samples to evaluate the field work approach. Detailed magnetic hysteresis analyses were used to obtain additional information on the magneto-mineralogy and grain-size distribution in order to deconvolute the magnetic bulk signal in terms of the different "natural" and "anthropogenic" ferruginous phases present in the samples and therefore allowing a better tracking of the pathways of the metallic pollutants.

  11. Heat and Mass Transfer in the Drying of a Cylindrical Body in an Oscillating Magnetic Field

    Science.gov (United States)

    Rudobashta, S. P.; Zueva, G. A.; Kartashov, É. M.

    2018-01-01

    A problem on the heating of a cylindrical body of infinite length in an oscillating electromagnetic field in the process of its drying has been formulated and solved analytically with account of the intermittence of irradiation of the body defined by the Heaviside unit function, the exponential-law absorption of electromagnetic energy by it, and the convective heat and mass exchange between the surface of the body and the environment having constant parameters. The intensity of evaporation of moisture from the surface of the body was determined on the basis of analytical solution of the problem on the mass transfer (moisture diffusion) in it on the assumption that the phase transformations of the body proceed near its surface. Solutions of the problem on the heating of the cylindrical body have been obtained for the cases of nonuniform and uniform distributions of its local temperature, the temperature of the body averaged over its volume, and the temperature gradient near the surface of the body. The "serviceability" of these solutions was verified on the basis of numerical simulation, with them, of the drying of a seed shaped as a cylinder under the action of an oscillating infrared radiation. As a result of the numerical simulation performed, a technological regime of drying of seeds at minimum and maximum temperatures of their heating by on oscillating infrared radiation for a definite period of time in a cycle, providing not only the drying of the seeds but also substantial improvement of their sowing properties (the sprouting energy and the germination power), has been found. It is shown that the oscillating infrared heating of seeds can be used for their drying in pseudofluidized and vibrofluidized beds.

  12. Adjoint Sensitivity Analysis of Radiative Transfer Equation: Temperature and Gas Mixing Ratio Weighting Functions for Remote Sensing of Scattering Atmospheres in Thermal IR

    Science.gov (United States)

    Ustinov, E.

    1999-01-01

    Sensitivity analysis based on using of the adjoint equation of radiative transfer is applied to the case of atmospheric remote sensing in the thermal spectral region with non-negligeable atmospheric scattering.

  13. A novel diagnostic parameter, foraminal stenotic ratio using three-dimensional magnetic resonance imaging, as a discriminator for surgery in symptomatic lumbar foraminal stenosis.

    Science.gov (United States)

    Yamada, Kentaro; Abe, Yuichiro; Satoh, Shigenobu; Yanagibashi, Yasushi; Hyakumachi, Takahiko; Masuda, Takeshi

    2017-08-01

    No previous studies have reported the radiological features of patients requiring surgery in symptomatic lumbar foraminal stenosis (LFS). This study aims to investigate the diagnostic accuracy of a novel technique, foraminal stenotic ratio (FSR), using three-dimensional magnetic resonance imaging for LFS at L5-S by comparing patients requiring surgery, patients with successful conservative treatment, and asymptomatic patients. This is a retrospective radiological comparative study. We assessed the magnetic resonance imaging (MRI) results of 84 patients (168 L5-S foramina) aged ≥40 years without L4-L5 lumbar spinal stenosis. The foramina were divided into three groups following standardized treatment: stenosis requiring surgery (20 foramina), stenosis with successful conservative treatment (26 foramina), and asymptomatic stenotic foramen (122 foramina). Foraminal stenotic ratio was defined as the ratio of the length of the stenosis to the length of the foramen on the reconstructed oblique coronal image, referring to perineural fat obliterations in whole oblique sagittal images. We also evaluated the foraminal nerve angle and the minimum nerve diameter on reconstructed images, and the Lee classification on conventional T1 images. The differences in each MRI parameter between the groups were investigated. To predict which patients require surgery, receiver operating characteristic (ROC) curves were plotted after calculating the area under the ROC curve. The FSR showed a stepwise increase when comparing asymptomatic, conservative, and surgical groups (mean, 8.6%, 38.5%, 54.9%, respectively). Only FSR was significantly different between the surgical and conservative groups (p=.002), whereas all parameters were significantly different comparing the symptomatic and asymptomatic groups. The ROC curve showed that the area under the curve for FSR was 0.742, and the optimal cutoff value for FSR for predicting a surgical requirement in symptomatic patients was 50

  14. Asymmetric angular dependence of spin-transfer torques in CoFe/Mg-B-O/CoFe magnetic tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Ling, E-mail: lingtang@zjut.edu.cn; Xu, Zhi-Jun, E-mail: xzj@zjut.edu.cn; Zuo, Xian-Jun; Yang, Ze-Jin, E-mail: zejinyang@zjut.edu.cn [Department of Applied Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023 (China); Gao, Qing-He [College of Science, Northeastern University, Shenyang 110004, China, Information Engineering College, Liaoning University of Traditional Chinese Medicine, Shenyang 110847 (China); Linghu, Rong-Feng, E-mail: linghu@gznu.edu.cn [School of Physics and Electronics Sciences, Guizhou Education University, Guiyang 550018 (China); Guo, Yun-Dong, E-mail: g308yd@126.com [College of Engineering and Technology, Neijiang Normal University, Neijiang 641112 (China)

    2016-04-28

    Using a first-principles noncollinear wave-function-matching method, we studied the spin-transfer torques (STTs) in CoFe/Mg-B-O/CoFe(001) magnetic tunnel junctions (MTJs), where three different types of B-doped MgO in the spacer are considered, including B atoms replacing Mg atoms (Mg{sub 3}BO{sub 4}), B atoms replacing O atoms (Mg{sub 4}BO{sub 3}), and B atoms occupying interstitial positions (Mg{sub 4}BO{sub 4}) in MgO. A strong asymmetric angular dependence of STT can be obtained both in ballistic CoFe/Mg{sub 3}BO{sub 4} and CoFe/Mg{sub 4}BO{sub 4} based MTJs, whereas a nearly symmetric STT curve is observed in the junctions based on CoFe/Mg{sub 4}BO{sub 3}. Furthermore, the asymmetry of the angular dependence of STT can be suppressed significantly by the disorder of B distribution. Such skewness of STTs in the CoFe/Mg-B-O/CoFe MTJs could be attributed to the interfacial resonance states induced by the B diffusion into MgO spacer.

  15. Matrix-algebra-based calculations of the time evolution of the binary spin-bath model for magnetization transfer.

    Science.gov (United States)

    Müller, Dirk K; Pampel, André; Möller, Harald E

    2013-05-01

    Quantification of magnetization-transfer (MT) experiments are typically based on the assumption of the binary spin-bath model. This model allows for the extraction of up to six parameters (relative pool sizes, relaxation times, and exchange rate constants) for the characterization of macromolecules, which are coupled via exchange processes to the water in tissues. Here, an approach is presented for estimating MT parameters acquired with arbitrary saturation schemes and imaging pulse sequences. It uses matrix algebra to solve the Bloch-McConnell equations without unwarranted simplifications, such as assuming steady-state conditions for pulsed saturation schemes or neglecting imaging pulses. The algorithm achieves sufficient efficiency for voxel-by-voxel MT parameter estimations by using a polynomial interpolation technique. Simulations, as well as experiments in agar gels with continuous-wave and pulsed MT preparation, were performed for validation and for assessing approximations in previous modeling approaches. In vivo experiments in the normal human brain yielded results that were consistent with published data. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. High resolution inelastic electron scattering on 90Zr at low momentum transfer and strong fragmentation of the magnetic quadrupole strength

    International Nuclear Information System (INIS)

    Meuer, D.; Frey, R.; Hoffmann, D.H.H.; Richter, A.; Spamer, E.; Titze, O.; Knuepfer, W.

    1980-01-01

    High-resolution (FWHM approx. 30 keV) inelastic electron scattering on 90 Zr at low momentum transfer (0.20 -1 ) has been used to study magnetic transitions at excitation energies Esub(x) = 8-10 MeV. The experimental data were analyzed in the distorted-wave Born approximation (DWBA) with wave functions calculated in the random phase approximation (RPA). Three Jsup(π) = 1 + states have been identified Esub(x) = 8.233, 9.000 and 9.371 MeV. There is some indication of further very fragmented dipole strength and the upper limit for the total M1 strength in the investigated energy region is ΣB(M1)up 2 sub(K). It is much smaller than any theoretical prediction. Furthermore, a large number of 2 - states has been observed, with the center of gravity located at Esub(x) approx. 9 MeV. These states carry a total strength of ΣB(M2)up = 1000 μ 2 sub(K) x fm 2 . Their strong fragmentation is in qualitative agreement with theoretical calculations, but the deduced strength is much smaller than theoretically predicted. In addition the distributions of spacings and radiative widths of the 2 - states are consistent with a Wigner and a Porter-Thomas distribution, respectively. (orig.)

  17. Most critical collimator-mask-magnet sequence in the SPS-to-LHC transfer lines: energy deposition study.

    CERN Document Server

    Marzo, Matteo; Lechner, Anton; Vlachoudis, Vasilis

    2017-01-01

    This technical note refers to a study on the relation between the impact conditions of the SPS 450GeV proton beam and the energy deposited downstream the Target Collimator Dump In- jection Long (TCDIL) collimators [1], in the SPS-to-LHC transfer lines TI2 and TI8. Such an analysis is relevant in order to simulate the worst scenario of failure, in case the beam impacts on the TCDIL collimator’s jaw, in the frame of the LHC Injectors Upgrade (LIU), in view of the High Luminosity LHC (HL-LHC) phase. Previous studies already showed the dependency of the energy deposited in the downstream masks on the collimators-masks distance [2]. In absence of a (realistic) impact parameter, we perform now a study to select the most pessimistic one, trying to understand the origin of the various components responsible for the energy deposition on the downstream mask and magnet. The set up of the Monte Carlo FLUKA [3] [4] simulations and the most relevant results will be presented in this document. A sensitivity analysis was a...

  18. Enhanced saturation magnetization of Fe3Si nanodot-embedded Fe80Si17Nb3 flexible film for efficient wireless power transfer

    International Nuclear Information System (INIS)

    Pai, Yi-Hao; Yan, Zih-Yu; Fu, Ping-Hao

    2013-01-01

    An efficient magnetically coupled resonance response is performed using an iron silicide-based nanostructured magnetoelectric material with high saturation magnetization for the wireless charging of battery-powered consumer electronics. With 500 °C annealing, the self-assembled Fe 3 Si nanodots buried in the Fe 80 Si 17 Nb 3 host matrix with (220) lattice spacing of 1.99 Å corresponding to a volume density of 8.96 × 10 16 cm 3 , can be obtained and a maximum saturation magnetization of 244 emu g −1 achieved. The return loss of the antenna will be tuned to match the designed frequency with greater attenuated intensity (−0.39 dB) and a relatively narrow bandwidth (6 kHz) when the Fe 3 Si nanodot-embedded Fe 80 Si 17 Nb 3 sample is placed in a WiTricity system. An efficient wireless power transfer can be created and improved from 47.5% to 97.3%. The associated coil and loop antenna resonators are significantly readjusted to match the power transfer by putting this nanostructured magnetoelectric material in a WiTricity system. - Highlights: • The saturation magnetization is effective enhancement in the presence of Fe 3 Si nanodot buried in the Fe 80 Si 17 Nb 3 . • A saturation magnetization of 244 emu g −1 is proposed for high-efficiency wireless power transfer. • The return loss of the antenna will be tuned to match the designed frequency. • Such a wireless power transfer can be enhanced efficiency up to 97.3%

  19. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  20. Effect of semen quality on human sex ratio in in vitro fertilization and intracytoplasmic sperm injection: an analysis of 27,158 singleton infants born after fresh single-embryo transfer.

    Science.gov (United States)

    Arikawa, Mikiko; Jwa, Seung Chik; Kuwahara, Akira; Irahara, Minoru; Saito, Hidekazu

    2016-04-01

    To evaluate the effect of semen quality on human sex ratio in in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI). Retrospective cohort study. Not applicable. A total of 27,158 singleton infants born between 2007 and 2012 after fresh single-embryo transfer. None. Proportion of male infants among liveborn infants. There were 14,996 infants born after IVF, 12,164 infants born after ICSI with ejaculated sperm, and 646 infants born after ICSI with nonejaculated sperm. The sex ratio of IVF was 53.1% (95% confidence interval [CI], 52.3-53.9); the sex ratio of ICSI with ejaculated and nonejaculated sperm demonstrated as statistically significant reduction (48.2%; 95% CI, 47.3-49.1 and 47.7%; 95% CI, 43.8-51.6, respectively). In IVF, lower sperm motility, including asthenozoospermia (sperm motility ratio compared with normal sperm (51.0%; 95% CI, 48.6-53.3 vs. 53.4%; 95% CI, 52.5-54.3). In ICSI with ejaculated sperm, there was no association between sperm motility and sex ratio. Sperm concentration was not associated with sex ratio in both IVF and ICSI. In IVF, lower sperm motility was associated with a statistically significant reduction in sex ratio; ICSI with either ejaculated or nonejaculated sperm was associated with a statistically significant reduction in sex ratio regardless of semen quality. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Heat transfer in cryogenic helium gas by turbulent Rayleigh-Bénard convection in a cylindrical cell of aspect ratio 1

    Czech Academy of Sciences Publication Activity Database

    Urban, Pavel; Hanzelka, Pavel; Musilová, Věra; Králík, Tomáš; La Mantia, M.; Srnka, Aleš; Skrbek, L.

    2014-01-01

    Roč. 16, č. 5 (2014), 053042: 1-40 ISSN 1367-2630 R&D Projects: GA ČR GPP203/12/P897 Institutional support: RVO:68081731 Keywords : Rayleigh-Bénard convection * heat transfer efficiency * cryogenic helium Subject RIV: BK - Fluid Dynamics Impact factor: 3.558, year: 2014

  2. Spectroscopic investigation and computational analysis of charge transfer hydrogen bonded reaction between 3-aminoquinoline with chloranilic acid in 1:1 stoichiometric ratio

    Science.gov (United States)

    Al-Ahmary, Khairia M.; Alenezi, Maha S.; Habeeb, Moustafa M.

    2015-10-01

    Charge transfer hydrogen bonded reaction between the electron donor (proton acceptor) 3-aminoquinoline with the electron acceptor (proton donor) chloranilic acid (H2CA) has been investigated experimentally and theoretically. The experimental work included the application of UV-vis spectroscopy to identify the charge transfer band of the formed complex, its molecular composition as well as estimating its formation constants in different solvent included acetonitrile (AN), methanol (MeOH), ethanol (EtOH) and chloroform (CHL). It has been recorded the presence of new absorption bands in the range 500-550 nm attributing to the formed complex. The molecular composition of the HBCT complex was found to be 1:1 (donor:acceptor) in all studied solvents based on continuous variation and photometric titration methods. In addition, the calculated formation constants from Benesi-Hildebrand equation recorded high values, especially in chloroform referring to the formation of stable HBCT complex. Infrared spectroscopy has been applied for the solid complex where formation of charge and proton transfer was proven in it. Moreover, 1H and 13C NMR spectroscopies were used to characterize the formed complex where charge and proton transfers were reconfirmed. Computational analysis included the use of GAMESS computations as a package of ChemBio3D Ultr12 program were applied for energy minimization and estimation of the stabilization energy for the produced complex. Also, geometrical parameters (bond lengths and bond angles) of the formed HBCT complex were computed and analyzed. Furthermore, Mullikan atomic charges, molecular potential energy surface, HOMO and LUMO molecular orbitals as well as assignment of the electronic spectra of the formed complex were presented. A full agreement between experimental and computational analysis has been found especially in the existence of the charge and proton transfers and the assignment of HOMO and LUMO molecular orbitals in the formed complex as

  3. High-time resolution measurements of upstream magnetic field and plasma conditions during flux transfer events at the Earth's dayside magnetopause

    International Nuclear Information System (INIS)

    Jacob, J.D.; Cattell, C.

    1993-01-01

    This paper presents preliminary analysis of six flux transfer events which were observed simultaneously by IRM and CCE. IRM was able to measure magnetic fields and pressures far from the earth, while CCE made observations at the earth's magnetopause. The objective is to better understand the coupling of energy and momentum into the earth's magnetosphere, by in this case trying to better understand the processes active in flux transfer events. For three of the events the observations were made on common field lines, and IRM observed fluctuations in B z large enough to cause a south to north swing in the interplanetary magnetic field (IMF). Pressure pulses were observed during two of these events. For the other three events there was no such consistent behavior of IMF direction or pressure pulses

  4. Investigation of tritium transfer to plants via the OBT/HTO and OBT/TFWT ratios; Etude du transfert du tritium aux vegetaux via les ratios OBT/HTO ET OBT/TFWT

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, C.; Guetat, P.; Vichot, L.; Losset, Y. [CEA Valduc, UMR, 21 - Is-sur-Tille (France); Boyer, C.; Fromm, M.; Mavon, C. [UMR CEA E4, Universite de Franche-Comte, 16 route de Gray, F-25030 Besancon cedex (France); Boyer, C.; Tatin-Froux, F.; Badot, P.M. [CNRS-Universite de Franche Comte / UMR 6249 Chrono-environnement usc INRA, Place Leclerc, F-25030 Besancon cedex (France)

    2009-07-01

    After having recalled some concepts used to distinguish the various forms of water present in plants, and the reactions in presence of tritium, the authors discuss the biochemical behaviour of tritium. Then, they briefly report a literature survey and, for different plants and crops, indicate the values of the OBT/HTO (organically bound tritium/tritiated water) and OBT/TFWT (organically bound tritium/tissue free water tritium) ratios. They also report experimental studies performed by exposures of lettuces at the vicinity of a nuclear installation

  5. Influence of Ba/Fe mole ratios on magnetic properties, crystallite size and shifting of X-ray diffraction peaks of nanocrystalline BaFe12O19 powder, prepared by sol gel auto combu

    Science.gov (United States)

    Suastiyanti, Dwita; Sudarmaji, Arif; Soegijono, Bambang

    2012-06-01

    Barium hexaferrite BaFe12O19 (BFO) is of great importance as permanent magnets, particularly for magnetic recording as well as in microwave devices. Nano-crystalline BFO powders were prepared by sol gel auto combustion method in citric acid - metal nitrates system. Hence the mole ratios of Ba/Fe were variated at 1:12; 1:11.5 and 1:11. Ratio of cation to fuel was fixed at 1:1. An appropriate amount of amonia solution was added dropwise to this solution with constant stirring until the PH reached 7 in all cases. Heating at 850oC for 10 hours for each sample to get final formation of BFO nanocrystalline. The data from XRD showing the lattice parameters a,c and the unit-cell volume V, confirm that BFO with ratio 1:12 has same crystall parameters with ratio 1:11. Ratio of Ba/Fe 1:12 and 1:11 have diffraction pattern similarly at almost each 2 θ for each samples. Ratio of Ba/Fe 1: 11.5 has the finest crystallite size 22 nm. Almost diffraction pattern peaks of Ba/Fe 1:11.5 move to the left from of Ba/Fe 1:12 then return to diffraction pattern of Ba/Fe 1:12 for Ba/Fe 1:11. SEM observations show the particle size less than 100 nm and the same shape for each sample. Ratio of Ba/Fe 1: 12 gives the highest intrinsic coercive Hc = 427.3 kA/m. The highest remanent magnetization is at ratio 1:11 with Mr = 0.170 T. BFO with mole ratio 1:11.5 has the finest grain 22 nm, good magnetic properties and the highest value of best FoM 89%.

  6. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  7. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  8. Enhanced forensic discrimination of pollutants by position-specific isotope analysis using isotope ratio monitoring by (13)C nuclear magnetic resonance spectrometry.

    Science.gov (United States)

    Julien, Maxime; Nun, Pierrick; Höhener, Patrick; Parinet, Julien; Robins, Richard J; Remaud, Gérald S

    2016-01-15

    In forensic environmental investigations the main issue concerns the inference of the original source of the pollutant for determining the liable party. Isotope measurements in geochemistry, combined with complimentary techniques for contaminant identification, have contributed significantly to source determination at polluted sites. In this work we have determined the intramolecular (13)C profiles of several molecules well-known as pollutants. By giving additional analytical parameters, position-specific isotope analysis performed by isotope ratio monitoring by (13)C nuclear magnetic resonance (irm-(13)C NMR) spectrometry gives new information to help in answering the major question: what is the origin of the detected contaminant? We have shown that isotope profiling of the core of a molecule reveals both the raw materials and the process used in its manufacture. It also can reveal processes occurring between the contamination site 'source' and the sampling site. Thus, irm-(13)C NMR is shown to be a very good complement to compound-specific isotope analysis currently performed by mass spectrometry for assessing polluted sites involving substantial spills of pollutant. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. The magnetic epoch-6 carbon shift: a change in the ocean's 13C/12C ratio 6.2 million years ago

    International Nuclear Information System (INIS)

    Vincent, E.; Killingley, J.S.; Berger, W.H.

    1980-01-01

    Tropical Indian Ocean planktonic and benthic foraminifera have 13 C/ 12 C ratios which change abruptly within Magnetic Epoch 6 about 6.2 million years ago. All species analyzed in the Late Miocene section of DSDP Site 238 show a shift towards lighter values of delta 13 C by about 0.8 per thousand. The oxygen isotope signal indicates that the pre-shift period is climatically quiet while the post-shift period has strong fluctuations. The authors suggest that the shift reflects a sudden increase in the rate of supply of organic carbon from coastal lowlands and from shelves exposed by regression, as well as a change in deep circulation patterns and ocean fertility. The event marks the transition of the ocean-atmosphere system from a quiet Early and Middle Neogene climate regime toward a Late Neogene regime characterized by climatic amplifying mechanisms (albedo feedback, bottom water production) located around the northern North Atlantic. The beginning of this regime may have been strongly influenced by the isolation of the Mediterranean basin. (Auth.)

  10. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  11. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  12. Time-resolved phosphorous magnetization transfer of the human calf muscle at 3 T and 7 T: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Valkovič, Ladislav, E-mail: siegfried.trattnig@meduniwien.ac.at [MR Center of Excellence, Department of Radiology, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria); Institute of Measurement Science, Department of Imaging Methods, Slovak Academy of Sciences, 841 04 Bratislava, Dúbravska cesta 9 (Slovakia); Chmelík, Marek, E-mail: marek.chmelik@meduniwien.ac.at [MR Center of Excellence, Department of Radiology, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria); Just Kukurova, Ivica, E-mail: ivica.kukurova@meduniwien.ac.at [MR Center of Excellence, Department of Radiology, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria); Krššák, Martin, E-mail: martin.krssak@meduniwien.ac.at [Department of Internal Medicine III, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria); Gruber, Stephan, E-mail: stephan@nmr.at [MR Center of Excellence, Department of Radiology, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria); Frollo, Ivan, E-mail: umerollo@savba.sk [Institute of Measurement Science, Department of Imaging Methods, Slovak Academy of Sciences, 841 04 Bratislava, Dúbravska cesta 9 (Slovakia); Trattnig, Siegfried, E-mail: siegfried.trattnig@meduniwien.ac.at [MR Center of Excellence, Department of Radiology, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria); Bogner, Wolfgang, E-mail: wolfgang@nmr.at [MR Center of Excellence, Department of Radiology, Medical University Vienna, A-1090 Wien, Lazarettgasse 14 (Austria)

    2013-05-15

    Phosphorous ({sup 31}P) magnetization transfer (MT) experiments enable the non-invasive investigation of human muscle metabolism in various physiological and pathological conditions. The purpose of our study was to investigate the feasibility of time-resolved MT, and to compare the results of MT experiments at 3 T and 7 T. Six healthy volunteers were examined on a 3 T and a 7 T MR scanner using the same setup and identical measurement protocols. In the calf muscle of all volunteers, four separate MT experiments (each ∼10 min duration) were performed in one session. The forward rate constant of the ATP synthesis reaction (k{sub ATP}) and creatine kinase reaction (k{sub CK}), as well as corresponding metabolic fluxes (F{sub ATP}, F{sub CK}), were estimated. A comparison of these exchange parameters, apparent T{sub 1}s, data quality, quantification precision, and reproducibility was performed. The data quality and reproducibility of the same MT experiments at 7 T was significantly higher (i.e., k{sub ATP} 2.7 times higher and k{sub CK} 3.4 times higher) than at 3 T (p < 0.05). The values for k{sub ATP} (p = 0.35) and k{sub CK} (p = 0.09) at both field strengths were indistinguishable. Even a single MT experiment at 7 T provided better data quality than did a 4 times-longer MT experiment at 3 T. The minimal time-resolution to reliably quantify both F{sub ATP} and F{sub CK} at 7 T was ∼6 min. Our results show that MT experiments at 7 T can be at least 4 times faster than 3 T MT experiments and still provide significantly better quantification. This enables time-resolved MT experiments for the observation of slow metabolic changes in the human calf muscle at 7 T.

  13. Time-resolved phosphorous magnetization transfer of the human calf muscle at 3 T and 7 T: A feasibility study

    International Nuclear Information System (INIS)

    Valkovič, Ladislav; Chmelík, Marek; Just Kukurova, Ivica; Krššák, Martin; Gruber, Stephan; Frollo, Ivan; Trattnig, Siegfried; Bogner, Wolfgang

    2013-01-01

    Phosphorous ( 31 P) magnetization transfer (MT) experiments enable the non-invasive investigation of human muscle metabolism in various physiological and pathological conditions. The purpose of our study was to investigate the feasibility of time-resolved MT, and to compare the results of MT experiments at 3 T and 7 T. Six healthy volunteers were examined on a 3 T and a 7 T MR scanner using the same setup and identical measurement protocols. In the calf muscle of all volunteers, four separate MT experiments (each ∼10 min duration) were performed in one session. The forward rate constant of the ATP synthesis reaction (k ATP ) and creatine kinase reaction (k CK ), as well as corresponding metabolic fluxes (F ATP , F CK ), were estimated. A comparison of these exchange parameters, apparent T 1 s, data quality, quantification precision, and reproducibility was performed. The data quality and reproducibility of the same MT experiments at 7 T was significantly higher (i.e., k ATP 2.7 times higher and k CK 3.4 times higher) than at 3 T (p < 0.05). The values for k ATP (p = 0.35) and k CK (p = 0.09) at both field strengths were indistinguishable. Even a single MT experiment at 7 T provided better data quality than did a 4 times-longer MT experiment at 3 T. The minimal time-resolution to reliably quantify both F ATP and F CK at 7 T was ∼6 min. Our results show that MT experiments at 7 T can be at least 4 times faster than 3 T MT experiments and still provide significantly better quantification. This enables time-resolved MT experiments for the observation of slow metabolic changes in the human calf muscle at 7 T

  14. Biochemical imaging of cervical intervertebral discs with glycosaminoglycan chemical exchange saturation transfer magnetic resonance imaging: feasibility and initial results

    International Nuclear Information System (INIS)

    Schleich, Christoph; Mueller-Lutz, Anja; Zimmermann, Lisa; Boos, Johannes; Wittsack, Hans-Joerg; Antoch, Gerald; Miese, Falk; Schmitt, Benjamin

    2016-01-01

    To evaluate glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging at 3T in the assessment of the GAG content of cervical IVDs in healthy volunteers. Forty-two cervical intervertebral discs of seven healthy volunteers (four females, three males; mean age: 21.4 ± 1.4 years; range: 19-24 years) were examined at a 3T MRI scanner in this prospective study. The MRI protocol comprised standard morphological, sagittal T2 weighted (T2w) images to assess the magnetic resonance imaging (MRI) based grading system for cervical intervertebral disc degeneration (IVD) and biochemical imaging with gagCEST to calculate a region-of-interest analysis of nucleus pulposus (NP) and annulus fibrosus (AF). GagCEST of cervical IVDs was technically successful at 3T with significant higher gagCEST values in NP compared to AF (1.17 % ± 1.03 % vs. 0.79 % ± 1.75 %; p = 0.005). We found topological differences of gagCEST values of the cervical spine with significant higher gagCEST effects in lower IVDs (r = 1; p = 0). We could demonstrate a significant, negative correlation between gagCEST values and cervical disc degeneration of NP (r = -0.360; p = 0.019). Non-degenerated IVDs had significantly higher gagCEST effects compared to degenerated IVDs in NP (1.76 % ± 0.92 % vs. 0.52 % ± 1.17 %; p < 0.001). Biochemical imaging of cervical IVDs is feasible at 3T. GagCEST analysis demonstrated a topological GAG distribution of the cervical spine. The depletion of GAG in the NP with increasing level of morphological degeneration can be assessed using gagCEST imaging. (orig.)

  15. Cu-water nanofluid flow induced by a vertical stretching sheet in presence of a magnetic field with convective heat transfer

    Directory of Open Access Journals (Sweden)

    Kalidas Das

    2017-09-01

    Full Text Available The convective heat transfer performance of nanofluid over a permeable stretching sheet with thermal convective boundary condition in presence of magnetic field and slip velocity is studied in the present paper. Cu-water nanofluid is used to investigate the effect of nanoparticles on the flow and heat transfer characteristic. The numerical results are compared with published results and are found in an excellent agreement. The influences of various relevant parameters on the velocity and temperature as well as the rate of shear stress and the rate of heat transfer are elucidated through graphs and tables. It is observed that nanoparticles volume fraction and surface convection parameter both increase the thickness of thermal boundary layer.

  16. Current induced multi-mode propagating spin waves in a spin transfer torque nano-contact with strong perpendicular magnetic anisotropy

    Science.gov (United States)

    Mohseni, S. Morteza; Yazdi, H. F.; Hamdi, M.; Brächer, T.; Mohseni, S. Majid

    2018-03-01

    Current induced spin wave excitations in spin transfer torque nano-contacts are known as a promising way to generate exchange-dominated spin waves at the nano-scale. It has been shown that when these systems are magnetized in the film plane, broken spatial symmetry of the field around the nano-contact induced by the Oersted field opens the possibility for spin wave mode co-existence including a non-linear self-localized spin-wave bullet and a propagating mode. By means of micromagnetic simulations, here we show that in systems with strong perpendicular magnetic anisotropy (PMA) in the free layer, two propagating spin wave modes with different frequency and spatial distribution can be excited simultaneously. Our results indicate that in-plane magnetized spin transfer nano-contacts in PMA materials do not host a solitonic self-localized spin-wave bullet, which is different from previous studies for systems with in plane magnetic anisotropy. This feature renders them interesting for nano-scale magnonic waveguides and crystals since magnon transport can be configured by tuning the applied current.

  17. Nuclear magnetic resonance studies of the phosphorus(v) pesticides. A rapid determination of the isomer ratio of systox1 1 Publication authorised by the Director U.S. Geological Survey.

    Science.gov (United States)

    Babad, H.; Taylor, T.N.; Goldberg, M.C.

    1968-01-01

    The integration circuit of the Varian A-60 nuclear magnetic resonance spectrometer is used in conjunction with vapor phase chromatography, to develop a rapid analysis technique for the determination of isomer ratios in technical Systox-Sulfotepp mixtures. The complete analysis requires less than 0.1 g of sample and only 15 min. The isomer ratio in the sample may be determined to an accuracy of ??1.5% and the undamaged sample may be recovered. ?? 1968.

  18. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  19. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  20. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  1. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  2. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  3. Super-paramagnetic core-shell material with tunable magnetic behavior by regulating electron transfer efficiency and structure stability of the shell

    Directory of Open Access Journals (Sweden)

    Wenyan Zhang

    Full Text Available In this work, a spherical nano core-shell material was constructed by encapsulating Fe3O4 microsphere into conductive polymer-metal composite shell. The Fe3O4 microspheres were fabricated by assembling large amounts of Fe3O4 nano-crystals, which endowed the microspheres with super-paramagnetic property and high saturation magnetization. The polymer-metal composite shell was constructed by inserting Pt nano-particles (NPs into the conductive polymer polypyrrole (PPy. As size and dispersion of the Pt NPs has an important influence on their surface area and surface energy, it was effective to enlarge the interface area between PPy and Pt NPs, enhance the electron transfer efficiency of PPy/Pt composite shell, and reinforced the shell’s structural stability just by tuning the size and dispersion of Pt NPs. Moreover, core-shell structure of the materials made it convenient to investigate the PPy/Pt shell’s shielding effect on the Fe3O4 core’s magnetic response to external magnetic fields. It was found that the saturation magnetization of Fe3O4/PPy/Pt core-shell material could be reduced by 20.5% by regulating the conductivity of the PPy/Pt shell. Keywords: Super-paramagnetic, Conductivity, Magnetic shielding, Structural stability

  4. Effect of external magnetic field on the Kβ/Kα X-ray intensity ratios of TixNi1-x alloys excited by 59.54 and 22.69keV photons.

    Science.gov (United States)

    Perişanoğlu, Ufuk; Alım, Bünyamin; Uğurlu, Mine; Demir, Lütfü

    2016-09-01

    The effects of external magnetic field and exciting photon energies on the Kβ/Kα X-ray intensity ratios of various alloy compositions of Ti-Ni transition metal alloys have been investigated in this work using X-ray fluorescence spectroscopy. The spectrum of characteristic K-X-ray photons from pure Ti, pure Ni and TixNi1-x (x=0.30; 0.40; 0.50; 0.60; 0.70) alloys were detected with a high resolution Si (Li) solid-state detector. Firstly, Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni and TixNi1-x alloys were measured following excitation by 59.54keV γ-rays from a 200mCi (241)Am radioactive point source without any magnetic field and under 0.5 and 1T external magnetic fields, separately. Later, the same measurements were repeated under the same experimental conditions for 22.69keV X-rays from a 370 MBq(1)(0)(9)Cd radioactive point source. The results obtained for Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni, Ti and Ni in various Ti-Ni alloys were evaluated in terms of both external magnetic field effect and exciting photon energy effect. When the results obtained for both exciting photon energies are evaluated in terms of changing of Kβ/Kα X-ray intensity ratios depending on the alloy composition, the tendency of these changes are observed to be similar. Also, Kβ/Kα X-ray intensity ratios for all samples examined have changed with increasing external magnetic field. Therefore, the results obtained have shown that Kβ/Kα X-ray intensity ratios of Ti and Ni in TixNi1-x alloys are connected with the external magnetic field. The present study makes it possible to perform reliable interpretation of experimental Kβ/Kα X-ray intensity ratios for Ti, Ni and TixNi1-x alloys and can also provide quantitative information about the changes of the Kβ/Kα X-ray intensity ratios of these metals with alloy composition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Golden Ratio

    Indian Academy of Sciences (India)

    Our attraction to another body increases if the body is symmetricaland in proportion. If a face or a structure is in proportion,we are more likely to notice it and find it beautiful.The universal ratio of beauty is the 'Golden Ratio', found inmany structures. This ratio comes from Fibonacci numbers.In this article, we explore this ...

  6. Golden Ratio

    Indian Academy of Sciences (India)

    Keywords. Fibonacci numbers, golden ratio, Sanskrit prosody, solar panel. Abstract. Our attraction to another body increases if the body is symmetricaland in proportion. If a face or a structure is in proportion,we are more likely to notice it and find it beautiful.The universal ratio of beauty is the 'Golden Ratio', found inmany ...

  7. Golden Ratio

    Indian Academy of Sciences (India)

    Our attraction to another body increases if the body is sym- metrical and in proportion. If a face or a structure is in pro- portion, we are more likely to notice it and find it beautiful. The universal ratio of beauty is the 'Golden Ratio', found in many structures. This ratio comes from Fibonacci numbers. In this article, we explore this ...

  8. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  9. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  10. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  11. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  12. Magnetic Field Emission Comparison at Different Quality Factors with Series-Parallel Compensation Network for Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    to the surroundings also increase with increase in the quality factor. In this paper, first analytical expressions are developed for comparing magnetic emissions at different quality factors. Theoretical and simulation (Comsol) results show comparatively lower increase for the magnetic field emissions to the linear...

  13. The impact of Co/La ratios on microstructure and magnetic properties of the Sr0.75−xCa0.25LaxFe12−yCoyO19 hexaferrites

    International Nuclear Information System (INIS)

    Yang, Yujie; Wang, Fanhou; Shao, Juxiang; Huang, Duohui; Liu, Xiansong; Feng, Shuangjiu; Wen, Cuie

    2015-01-01

    Hexagonal ferrite Sr 0.75−x Ca 0.25 La x Fe 12−y Co y O 19 magnetic powder and magnets were synthesized according to a ceramic process. The phase compositions of the magnetic powder samples were determined by X-ray diffraction. There is a single magnetoplumbite phase in the samples with y/x from 0.3 to 0.6, and when y/x>0.6, the CoFe 2 O 4 phase is observed. The micrographs of the sintered magnets were observed by a field emission scanning electron microscopy. The magnets have formed the hexagonal structures and the particles are distributed inhomogeneously. The impact of Co/La ratios on magnetic properties of the magnets was studied systematically. The remanence, magnetic induction coercivity and maximum energy product of the magnets first increase with y/x from 0.3 to 0.6, and then decrease when y/x>0.6. However, the intrinsic coercivity of the magnets first increases with y/x from 0.3 to 0.9, and decreases when y/x>0.9. The rectangularity of the demagnetizing curves for the magnets decreases with increasing y/x. - Highlights: • Sr 0.75−x Ca 0.25 La x Fe 12−y Co y O 19 hexagonal ferrites were synthesized according to a ceramic process. • There is a single magnetoplumbite phase in the samples with y/x from 0.3 to 0.6, and when y/x is above 0.7, the CoFe 2 O 4 phase is observed. • B r , H cb and (BH) max of the magnets first increase with y/x from 0.3 to 0.6, and then, decrease when y/x continues to increase. • H cj of the magnets first increases with y/x from 0.3 to 0.9, and then, decreases when y/x is above 0.9. • The rectangularity of the demagnetizing curves for the magnets decreases with the increase of y/x

  14. Sex ratios

    OpenAIRE

    West, Stuart A; Reece, S E; Sheldon, Ben C

    2002-01-01

    Sex ratio theory attempts to explain variation at all levels (species, population, individual, brood) in the proportion of offspring that are male (the sex ratio). In many cases this work has been extremely successful, providing qualitative and even quantitative explanations of sex ratio variation. However, this is not always the situation, and one of the greatest remaining problems is explaining broad taxonomic patterns. Specifically, why do different organisms show so ...

  15. Simulation Research of Magnetically-coupled Resonant Wireless Power Transfer System with Single Intermediate Coil Resonator Based on S Parameters Using ANSYS

    Directory of Open Access Journals (Sweden)

    Liu Cheng

    2016-01-01

    Full Text Available ANSYS can be a powerful tool to simulate the process of energy exchange in magnetically-coupled resonant wireless power transfer system. In this work, the MCR-WPT system with single intermediate coil resonator is simulated and researched based on scattering parameters using ANSYS Electromagnetics. The change rule of power transfer efficiency is reflected intuitively through the scattering parameters. A new method of calculating the coupling coefficient is proposed. A cascaded 2-port network model using scattering parameters is adopted to research the efficiency of transmission. By changing the relative position and the number of turns of the intermediate coil, we find some factors affecting the efficiency of transmission. Methods and principles of designing the MCR-WPT system with single intermediate coil resonator are obtained. And these methods have practical value with design and optimization of system efficiency.

  16. Effect of polarized radiative transfer on the Hanle magnetic field determination in prominences: Analysis of hydrogen H alpha line observations at Pic-du-Midi

    Science.gov (United States)

    Bommier, V.; Deglinnocenti, E. L.; Leroy, J. L.; Sahal-Brechot, S.

    1985-01-01

    The linear polarization of the Hydrogen H alpha line of prominences has been computed, taking into account the effect of a magnetic field (Hanle effect), of the radiative transfer in the prominence, and of the depolarization due to collisions with the surrounding electrons and protons. The corresponding formalisms are developed in a forthcoming series of papers. In this paper, the main features of the computation method are summarized. The results of computation have been used for interpretation in terms of magnetic field vector measurements from H alpha polarimetric observations in prominences performed at Pic-du-Midi coronagraph-polarimeter. Simultaneous observations in one optically thin line (He I D(3)) and one optically thick line (H alpha) give an opportunity for solving the ambiguity on the field vector determination.

  17. Symmetric and Asymmetric Magnetic Tunnel Junctions with Embedded Nanoparticles: Effects of Size Distribution and Temperature on Tunneling Magnetoresistance and Spin Transfer Torque.

    Science.gov (United States)

    Useinov, Arthur; Lin, Hsiu-Hau; Lai, Chih-Huang

    2017-08-21

    The problem of the ballistic electron tunneling is considered in magnetic tunnel junction with embedded non-magnetic nanoparticles (NP-MTJ), which creates additional conducting middle layer. The strong temperature impact was found in the system with averaged NP diameter d av  tunneling magnetoresistance (TMR) voltage behaviors. The low temperature approach also predicts step-like TMR and quantized in-plane spin transfer torque (STT) effects. The robust asymmetric STT respond is found due to voltage sign inversion in NP-MTJs with barrier asymmetry. Furthermore, it is shown how size distribution of NPs as well as quantization rules modify the spin-current filtering properties of the nanoparticles in ballistic regime. Different quantization rules for the transverse component of the wave vector are considered to overpass the dimensional threshold (d av  ≈ 1.8 nm) between quantum well and bulk-assisted states of the middle layer.

  18. Leaf gas exchange, fv/fm ratio, ion content and growth conditions of the two moringa species under magnetic water treatment

    International Nuclear Information System (INIS)

    Hasan, M.M.; Alharby, H.F.; Hajar, A.; Hakeem, K.R.

    2017-01-01

    The current greenhouse experiment investigates the role of magnetic water on the two Moringa species (Moringa oleifera and Moringa peregrina). Both species were exposed to the magnetic field (30 mT). The magnetic water increased the plant height, leaf number, leaflet number, and internode distances in both the species, respectively. Relative water content (RWC) and leaf area in both the species showed changes under magnetic water treatment. The results showed in magnetic water treatment, the leaf gas exchange parameters such as assimilation (A), stomatal conductance (gs), transpiration rate (E), and vapor pressure deficit (VPD) were increased. Similarly, Photosynthetic pigments (Chl a, Chl b, Chl (a+b), Carotenoids), photosynthetic water use efficiency (WUE) were also increased significantly. Magnetized water had also significant effects on the maximal efficiency of PSII photochemistry (Fv/Fm). Our study suggested that magnetic water treatment could be used as an environment-friendly technology for improving the growth and physiology of Moringa species. In addition, this technology could be further incorporated into the traditional methods of agriculture for the improvement of crop plants, particularly in the arid and sub-arid areas of the world. (author)

  19. Molecular orbital (SCF-X-α-SW) theory of Fe2+-Mn3+, Fe3+-Mn2+, and Fe3+-Mn3+ charge transfer and magnetic exchange in oxides and silicates

    Science.gov (United States)

    Sherman, David M.

    1990-01-01

    Metal-metal charge-transfer and magnetic exchange interactions have important effects on the optical spectra, crystal chemistry, and physics of minerals. Previous molecular orbital calculations have provided insight on the nature of Fe2+-Fe3+ and Fe2+-Ti4+ charge-transfer transitions in oxides and silicates. In this work, spin-unrestricted molecular orbital calculations on (FeMnO10) clusters are used to study the nature of magnetic exchange and electron delocalization (charge transfer) associated with Fe3+-Mn2+, Fe3+-Mn3+, and Fe2+-Mn3+ interactions in oxides and silicates. 

  20. Apparatus and method for transfer of information by means of a curl-free magnetic vector potential field

    International Nuclear Information System (INIS)

    Gelinas, R.C.

    1984-01-01

    A system for transmission of information using a curl-free magnetic vector potential radiation field. The system includes current-carrying apparatus for generating a magnetic vector potential field with a curl-free component coupled to apparatus for modulating the current applied to the field generating apparatus. Receiving apparatus includes a detector with observable properties that vary with the application of an applied curl-free magnetic vector potential field. Analyzing apparatus for determining the information content of modulation imposed on the curl-free vector potential field can be established in materials that are not capable of transmitting more common electromagnetic radiation

  1. Magnetic Field Emission Comparison for Series-Parallel and Series-Series Wireless Power Transfer to Vehicles – PART 2/2

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Series-series and series-parallel topologies are the most favored topologies for design of wireless power transfer system for vehicle applications. The series-series topology has the advantage of reflecting only the resistive part on the primary side. On the other hand, the current source output...... characteristics of the series-parallel topology are more suited for the battery of the vehicle. This paper compares the two topologies in terms of magnetic emissions to the surroundings for the same input power, primary current, quality factor and inductors. Theoretical and simulation results show that the series...

  2. Magnetic Field Emission Comparison for Series-Parallel and Series-Series Wireless Power Transfer to Vehicles – PART 1/2

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Resonant circuits of wireless power transfer system can be designed in four possible ways by placing the primary and secondary capacitor in a series or parallel order with respect to the corresponding inductor. The two topologies series-parallel and series-series under investigation have been...... already compared in terms of their output behavior (current or voltage source) and reflection of the secondary impedance on the primary side. In this paper it is shown that for the same power rating series-parallel topology emits lesser magnetic fields to the surroundings than its series...

  3. Nanoscale control of stripe-ordered magnetic domain walls by vertical spin transfer torque in La0.67Sr0.33MnO3 film

    Science.gov (United States)

    Wang, Jing; Wu, Shizhe; Ma, Ji; Xie, Lishan; Wang, Chuanshou; Malik, Iftikhar Ahmed; Zhang, Yuelin; Xia, Ke; Nan, Ce-Wen; Zhang, Jinxing

    2018-02-01

    Stripe-ordered domains with perpendicular magnetic anisotropy have been intensively investigated due to their potential applications in high-density magnetic data-storage devices. However, the conventional control methods (e.g., epitaxial strain, local heating, magnetic field, and magnetoelectric effect) of the stripe-ordered domain walls either cannot meet the demands for miniaturization and low power consumption of spintronic devices or require high strength of the electric field due to the small value of the magnetoelectric effect at room temperature. Here, a domain-wall resistive effect of 0.1% was clarified in La0.67Sr0.33MnO3 thin films between the configurations of current in the plane and perpendicular to the plane of walls. Furthermore, a reversible nanoscale control of the domain-wall re-orientation by vertical spin transfer torque across the probe/film interface was achieved, where a probe voltage of 0.1 V was applied on a manganite-based capacitor. We also demonstrated that the stripe-ordered magnetic domain-wall re-orientation strongly depends on the AC frequency of the scanning probe voltage which was applied on the capacitor.

  4. On the Equality Assumption of Latent and Sensible Heat Energy Transfer Coefficients of the Bowen Ratio Theory for Evapotranspiration Estimations: Another Look at the Potential Causes of Inequalities

    Directory of Open Access Journals (Sweden)

    Suat Irmak

    2014-08-01

    Full Text Available Evapotranspiration (ET and sensible heat (H flux play a critical role in climate change; micrometeorology; atmospheric investigations; and related studies. They are two of the driving variables in climate impact(s and hydrologic balance dynamics. Therefore, their accurate estimate is important for more robust modeling of the aforementioned relationships. The Bowen ratio energy balance method of estimating ET and H diffusions depends on the assumption that the diffusivities of latent heat (KV and sensible heat (KH are always equal. This assumption is re-visited and analyzed for a subsurface drip-irrigated field in south central Nebraska. The inequality dynamics for subsurface drip-irrigated conditions have not been studied. Potential causes that lead KV to differ from KH and a rectification procedure for the errors introduced by the inequalities were investigated. Actual ET; H; and other surface energy flux parameters using an eddy covariance system and a Bowen Ratio Energy Balance System (located side by side on an hourly basis were measured continuously for two consecutive years for a non-stressed and subsurface drip-irrigated maize canopy. Most of the differences between KV and KH appeared towards the higher values of KV and KH. Although it was observed that KV was predominantly higher than KH; there were considerable data points showing the opposite. In general; daily KV ranges from about 0.1 m2∙s−1 to 1.6 m2∙s−1; and KH ranges from about 0.05 m2∙s−1 to 1.1 m2∙s−1. The higher values for KV and KH appear around March and April; and around September and October. The lower values appear around mid to late December and around late June to early July. Hourly estimates of KV range between approximately 0 m2∙s−1 to 1.8 m2∙s−1 and that of KH ranges approximately between 0 m2∙s−1 to 1.7 m2∙s−1. The inequalities between KV and KH varied diurnally as well as seasonally. The inequalities were greater during the non

  5. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  6. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  7. Heat transfer in flow past a continuously moving semi-infinite flat plate in transverse magnetic field with heat flux

    Digital Repository Service at National Institute of Oceanography (India)

    Murty, T.V.R.

    Thermal boundary layer on a continuously moving semi-infinite flat plate in the presence of transverse magnetic field with heat flux has been examined. Similarity solutions have been derived and the resulting equations are integrated numerically...

  8. First Observation of the High Field Side Sawtooth Crash and Heat Transfer during Driven Reconnection Processes in Magnetically Confined Plasmas

    International Nuclear Information System (INIS)

    Park, HK; Luhmann, NC; Donne, AJH; Classen, IGJ; Domier, CW; Mazzucato, E; Munsat, T; van de Pol, MJ; Xia, Z

    2005-01-01

    High resolution (temporal and spatial), two-dimensional images of electron temperature fluctuations during sawtooth oscillations were employed to study driven reconnection processes in magnetically confined toroidal plasmas. The combination of kink and local pressure driven instabilities leads to an 'X-point' reconnection process that is localized in the toroidal and poloidal planes. The reconnection is not always confined to the magnetic surfaces with minimum energy. The heat transport process from the core is demonstrated to be highly collective rather than stochastic

  9. Biot-Savart Law Application in Wireless Power Transfer – Dependence of Magnetic Field to Angle Position

    Directory of Open Access Journals (Sweden)

    Bogdan IUGA

    2017-12-01

    Full Text Available The magnetic field of a closed loop of conductive wire can be computed due to Biot-Savart law, which analyses the value of the field at an exterior point from the transversal axis. If the measure point is out of the axis then the magnetic field has completely different values. A general stated form of this law can measure the value in any point, in relation to Euclidian distance from the loop.

  10. Effects on heat transfer of multiphase magnetic fluid due to circular magnetic field over a stretching surface with heat source/sink and thermal radiation

    Directory of Open Access Journals (Sweden)

    A. Zeeshan

    Full Text Available The purpose of the current article is to explore the boundary layer heat transport flow of multiphase magnetic fluid with solid impurities suspended homogeneously past a stretching sheet under the impact of circular magnetic field. Thermal radiation effects are also taken in account. The equations describing the flow of dust particles in fluid along with point dipole are modelled by employing conservation laws of mass, momentum and energy, which are then converted into non-linear coupled differential equations by mean of similarity approach. The transformed ODE’s are tackled numerically with the help of efficient Runga-Kutta method. The influence of ferromagnetic interaction parameter, viscous dissipation, fluid-particle interaction parameter, Eckert number, Prandtl number, thermal radiation parameter and number of dust particles, heat production or absorption parameter with the two thermal process namely, prescribed heat flux (PHF or prescribed surface temperature (PST are observed on temperature and velocity profiles. The value of skin-friction coefficient and Nusselt number are calculated for numerous physical parameters. Present results are correlated with available for a limited case and an excellent agreement is found. Keywords: Ferromagnetic interaction parameter, Dusty magnetic fluid, stretching sheet, Magnetic dipole, Heat source/sink, Thermal radiation

  11. Alterations in brain white matter contributing to age-related slowing of task switching performance : The role of radial diffusivity and magnetization transfer ratio

    NARCIS (Netherlands)

    Serbruyns, Leen; Leunissen, Inge; van Ruitenbeek, Peter; Pauwels, Lisa; Caeyenberghs, Karen; Solesio-Jofre, Elena; Geurts, Monique; Cuypers, Koen; Meesen, Raf L.; Sunaert, Stefan; Leemans, Alexander; Swinnen, Stephan P.

    2016-01-01

    Successfully switching between tasks is critical in many daily activities. Age-related slowing of this switching behavior has been documented extensively, but the underlying neural mechanisms remain unclear. Here, we investigated the contribution of brain white matter changes associated with myelin

  12. Influence of cooling rate in planar thermally assisted magnetic random access memory: Improved writeability due to spin-transfer-torque influence

    International Nuclear Information System (INIS)

    Chavent, A.; Ducruet, C.; Portemont, C.; Creuzet, C.; Alvarez-Hérault, J.; Vila, L.; Sousa, R. C.; Prejbeanu, I. L.; Dieny, B.

    2015-01-01

    This paper investigates the effect of a controlled cooling rate on magnetic field reversal assisted by spin transfer torque (STT) in thermally assisted magnetic random access memory. By using a gradual linear decrease of the voltage at the end of the write pulse, the STT decays more slowly or at least at the same rate as the temperature. This condition is necessary to make sure that the storage layer magnetization remains in the desired written direction during cooling of the cell. The influence of the write current pulse decay rate was investigated on two exchange biased synthetic ferrimagnet (SyF) electrodes. For a NiFe based electrode, a significant improvement in writing reproducibility was observed using a gradual linear voltage transition. The write error rate decreases by a factor of 10 when increasing the write pulse fall-time from ∼3 ns to 70 ns. For comparison, a second CoFe/NiFe based electrode was also reversed by magnetic field assisted by STT. In this case, no difference between sharp and linear write pulse fall shape was observed. We attribute this observation to the higher thermal stability of the CoFe/NiFe electrode during cooling. In real-time measurements of the magnetization reversal, it was found that Ruderman-Kittel-Kasuya-Yosida (RKKY) coupling in the SyF electrode vanishes for the highest pulse voltages that were used due to the high temperature reached during write. As a result, during the cooling phase, the final state is reached through a spin-flop transition of the SyF storage layer

  13. Application of Laplace transform for the exact effect of a magnetic field on heat transfer of carbon nanotubes-suspended nanofluids

    Energy Technology Data Exchange (ETDEWEB)

    Ebaid, Abdelhalim; Al Sharif, Mohammed A. [Tabuk Univ. (Saudi Arabia). Faculty of Science

    2015-10-01

    Since the discovery of the carbon nanotubes (CNTs), there is an increasing interest in their applications in industry and medical fields. Attempts of using such CNTs as drug carriers and in cancer therapy in the presence of a magnetic field are now undertaken because of their direct impacts on increasing the thermal conductivity of base fluids. Two types of CNTs are well known for the researchers, the single-walled CNT (SWCNTs) and the multi-walled CNTs (MWCNTs); however, the subject of which one is more effective in treatment of cancer deserves more investigations. The present article discusses the effect of such types of CNTs on the flow and heat transfer of nanofluids in the presence of a magnetic field. Exact analytical solution for the heat equation has been obtained by using the Laplace transform, where the solution is expressed in terms of a new special function, the generalised incomplete gamma function. The effects of various parameters on the fluid velocity, temperature distribution, and heat transfer rates have been introduced. Details of possible applications of the current results in the treatment of cancer have been also discussed.

  14. Application of Laplace transform for the exact effect of a magnetic field on heat transfer of carbon nanotubes-suspended nanofluids

    International Nuclear Information System (INIS)

    Ebaid, Abdelhalim; Al Sharif, Mohammed A.

    2015-01-01

    Since the discovery of the carbon nanotubes (CNTs), there is an increasing interest in their applications in industry and medical fields. Attempts of using such CNTs as drug carriers and in cancer therapy in the presence of a magnetic field are now undertaken because of their direct impacts on increasing the thermal conductivity of base fluids. Two types of CNTs are well known for the researchers, the single-walled CNT (SWCNTs) and the multi-walled CNTs (MWCNTs); however, the subject of which one is more effective in treatment of cancer deserves more investigations. The present article discusses the effect of such types of CNTs on the flow and heat transfer of nanofluids in the presence of a magnetic field. Exact analytical solution for the heat equation has been obtained by using the Laplace transform, where the solution is expressed in terms of a new special function, the generalised incomplete gamma function. The effects of various parameters on the fluid velocity, temperature distribution, and heat transfer rates have been introduced. Details of possible applications of the current results in the treatment of cancer have been also discussed.

  15. Magnetic

    Science.gov (United States)

    Aboud, Essam; El-Masry, Nabil; Qaddah, Atef; Alqahtani, Faisal; Moufti, Mohammed R. H.

    2015-06-01

    The Rahat volcanic field represents one of the widely distributed Cenozoic volcanic fields across the western regions of the Arabian Peninsula. Its human significance stems from the fact that its northern fringes, where the historical eruption of 1256 A.D. took place, are very close to the holy city of Al-Madinah Al-Monawarah. In the present work, we analyzed aeromagnetic data from the northern part of Rahat volcanic field as well as carried out a ground gravity survey. A joint interpretation and inversion of gravity and magnetic data were used to estimate the thickness of the lava flows, delineate the subsurface structures of the study area, and estimate the depth to basement using various geophysical methods, such as Tilt Derivative, Euler Deconvolution and 2D modeling inversion. Results indicated that the thickness of the lava flows in the study area ranges between 100 m (above Sea Level) at the eastern and western boundaries of Rahat Volcanic field and getting deeper at the middle as 300-500 m. It also showed that, major structural trend is in the NW direction (Red Sea trend) with some minor trends in EW direction.

  16. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  17. MAGNET

    CERN Document Server

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  18. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  19. Quantum size effects on spin-transfer torque in a double barrier magnetic tunnel junction with a nonmagnetic-metal (semiconductor) spacer

    International Nuclear Information System (INIS)

    Daqiq, Reza; Ghobadi, Nader

    2016-01-01

    We study the quantum size effects of an MgO-based double barrier magnetic tunnel junction with a nonmagnetic-metal (DBMTJ-NM) (semiconductor (DBMTJ-SC)) spacer on the charge current and the spin-transfer torque (STT) components using non-equilibrium Green's function (NEGF) formalism. The results show oscillatory behavior due to the resonant tunneling effect depending on the structure parameters. We find that the charge current and the STT components in the DBMTJ-SC demonstrate the magnitude enhancement in comparison with the DBMTJ-NM. The bias dependence of the STT components in a DBMTJ-NM shows different behavior in comparison with spin valves and conventional MTJs. Therefore, by choosing a specific SC spacer with suitable thickness in a DBMTJ the charge current and the STT components significantly increase so that one can design a device with high STT and faster magnetization switching. - Highlights: • The quantum size effects are studied in double barrier magnetic tunnel junctions. • Spin torque (ST) components oscillate for increasing of middle spacer thicknesses. • Due to the resonant tunneling in the quantum well, oscillations have appeared. • By replacement a metal spacer with a semiconductor (ZnO) ST has increased. • The ST components vs. bias show gradually decreasing unlike spin valves or MTJs.

  20. Quantum size effects on spin-transfer torque in a double barrier magnetic tunnel junction with a nonmagnetic-metal (semiconductor) spacer

    Energy Technology Data Exchange (ETDEWEB)

    Daqiq, Reza; Ghobadi, Nader

    2016-07-15

    We study the quantum size effects of an MgO-based double barrier magnetic tunnel junction with a nonmagnetic-metal (DBMTJ-NM) (semiconductor (DBMTJ-SC)) spacer on the charge current and the spin-transfer torque (STT) components using non-equilibrium Green's function (NEGF) formalism. The results show oscillatory behavior due to the resonant tunneling effect depending on the structure parameters. We find that the charge current and the STT components in the DBMTJ-SC demonstrate the magnitude enhancement in comparison with the DBMTJ-NM. The bias dependence of the STT components in a DBMTJ-NM shows different behavior in comparison with spin valves and conventional MTJs. Therefore, by choosing a specific SC spacer with suitable thickness in a DBMTJ the charge current and the STT components significantly increase so that one can design a device with high STT and faster magnetization switching. - Highlights: • The quantum size effects are studied in double barrier magnetic tunnel junctions. • Spin torque (ST) components oscillate for increasing of middle spacer thicknesses. • Due to the resonant tunneling in the quantum well, oscillations have appeared. • By replacement a metal spacer with a semiconductor (ZnO) ST has increased. • The ST components vs. bias show gradually decreasing unlike spin valves or MTJs.